Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Manual de Quemador

Download as pdf or txt
Download as pdf or txt
You are on page 1of 56

M039247CA Rel 0.

3 06/2010
BURNERS - BRUCIATORI - BRULERS - BRENNER - QUEMADORES -
Gas burners
MANUAL OF INSTALLATION - USE - MAINTENANCE
P61-P65
P71-P73A
2
TABLE OF CONTENTS
WARNINGS ................................................................................................................................................................ 3
PART I: INSTALLATION MANUAL .......................................................................................................................... 5
Burner model identification ............................................................................................................................................................. 5
Specifications .................................................................................................................................................................................. 5
Country and usefulness gas categories .......................................................................................................................................... 6
Overall dimensions ......................................................................................................................................................................... 7
Performance curves ...................................................................................................................................................................... 10
MOUNTINGS AND CONNECTIONS ............................................................................................................................................ 12
Packing ......................................................................................................................................................................................... 12
Fitting the burner to the boiler ....................................................................................................................................................... 12
Matching the burner to the boiler .................................................................................................................................................. 12
Gas train connections ................................................................................................................................................................... 13
Assembling the gas grain .............................................................................................................................................................. 14
Siemens VGD20.. and VGD40.. gas valves - with SKP2.. (pressure governor) ......................................................................... 16
Pressure adjusting range .............................................................................................................................................................. 16
Gas Proving System VPS504 ....................................................................................................................................................... 17
Electrical connections ................................................................................................................................................................... 18
Rotation of fan motor .................................................................................................................................................................... 19
ADJUSTMENTS ........................................................................................................................................................................... 20
Combustion head gas pressure curves depending on the flow rate ............................................................................................. 20
Measuring the gas pressure in the combustion head ................................................................................................................... 20
Gas pressure in combustion head vs. gas flow rate curves .......................................................................................................... 21
Adjusting air and gas flow rates .................................................................................................................................................... 22
Startup Output ............................................................................................................................................................................... 22
Adjustments - brief description ...................................................................................................................................................... 22
Adjusting procedure ...................................................................................................................................................................... 22
Progressive burners ...................................................................................................................................................................... 26
Fully modulating burners ............................................................................................................................................................... 27
Calibration of air and gas pressure switches ................................................................................................................................ 27
Calibration of air pressure switch .................................................................................................................................................. 27
Calibration of low gas pressure switch .......................................................................................................................................... 27
Adjusting the high gas pressure switch (when provided) .............................................................................................................. 27
PART II: OPERATION ............................................................................................................................................. 28
OPERATION................................................................................................................................................................................. 29
PART III: MAINTENANCE....................................................................................................................................... 31
ROUTINE MAINTENANCE ........................................................................................................................................................... 31
Removing the filter in theMULTIBLOC DUNGS MB-DLE 415 - 420 ............................................................................................. 31
Inspection and replacement of the MULTIBLOC DUNGS MBC..SE filter (Threaded valves group) ............................................ 32
Gas filter maintenance .................................................................................................................................................................. 32
Removing the combustion head ................................................................................................................................................... 32
Adjusting the electrodes ................................................................................................................................................................ 33
Replacing the electrodes .............................................................................................................................................................. 34
Checking the detection current ..................................................................................................................................................... 34
Seasonal stop ............................................................................................................................................................................... 35
Burner disposal ............................................................................................................................................................................. 35
TROUBLESHOOTING .................................................................................................................................................................. 36
SPARE PARTS............................................................................................................................................................................. 37
BURNER EXPLODED VIEW......................................................................................................................................................... 38
WIRING DIAGRAMS .................................................................................................................................................................... 42
APPENDIX
3
WARNINGS
THIS MANUAL IS SUPPLIED AS AN INTEGRAL AND ESSENTIAL PART OF THE PRODUCT AND MUST BE DELIVERED TO THE
USER.
INFORMATION INCLUDED IN THIS SECTION ARE DEDICATED BOTH TO THE USER AND TO PERSONNEL FOLLOWING PRO-
DUCT INSTALLATION AND MAINTENANCE.
THE USER WILL FIND FURTHER INFORMATION ABOUT OPERATING AND USE RESTRICTIONS, IN THE SECOND SECTION
OF THIS MANUAL. WE HIGHLY RECOMMEND TO READ IT.
CAREFULLY KEEP THIS MANUAL FOR FUTURE REFERENCE.
1) GENERAL INTRODUCTION
The equipment must be installed in compliance with the regulations
in force, following the manufacturers instructions, by qualified per-
sonnel.
Qualified personnel means those having technical knowledge in the
field of components for civil or industrial heating systems, sanitary
hot water generation and particularly service centres authorised by
the manufacturer.
Improper installation may cause injury to people and animals, or
damage to property, for which the manufacturer cannot be held lia-
ble.
Remove all packaging material and inspect the equipment for inte-
grity.
In case of any doubt, do not use the unit - contact the supplier.
The packaging materials (wooden crate, nails, fastening devices, plastic
bags, foamed polystyrene, etc), should not be left within the reach of chil-
dren, as they may prove harmful.
Before any cleaning or servicing operation, disconnect the unit from
the mains by turning the master switch OFF, and/or through the cut-
out devices that are provided.
Make sure that inlet or exhaust grilles are unobstructed.
In case of breakdown and/or defective unit operation, disconnect the
unit. Make no attempt to repair the unit or take any direct action.
Contact qualified personnel only.
Units shall be repaired exclusively by a servicing centre, duly authorised
by the manufacturer, with original spare parts.
Failure to comply with the above instructions is likely to impair the units
safety.
To ensure equipment efficiency and proper operation, it is essential that
maintenance operations are performed by qualified personnel at regular
intervals, following the manufacturers instructions.
When a decision is made to discontinue the use of the equipment,
those parts likely to constitute sources of danger shall be made har-
mless.
In case the equipment is to be sold or transferred to another user, or
in case the original user should move and leave the unit behind,
make sure that these instructions accompany the equipment at all
times so that they can be consulted by the new owner and/or the
installer.
For all the units that have been modified or have options fitted then
original accessory equipment only shall be used.
This unit shall be employed exclusively for the use for which it is
meant. Any other use shall be considered as improper and, there-
fore, dangerous.
The manufacturer shall not be held liable, by agreement or otherwise, for
damages resulting from improper installation, use and failure to comply
with the instructions supplied by the manufacturer.
2) SPECIAL INSTRUCTIONS FOR BURNERS
The burner should be installed in a suitable room, with ventilation
openings complying with the requirements of the regulations in force,
and sufficient for good combustion.
Only burners designed according to the regulations in force should
be used.
This burner should be employed exclusively for the use for which it
was designed.
Before connecting the burner, make sure that the unit rating is the
same as delivery mains (electricity, gas oil, or other fuel).
Observe caution with hot burner components. These are, usually,
near to the flame and the fuel pre-heating system, they become hot
during the unit operation and will remain hot for some time after the
burner has stopped.
When the decision is made to discontinue the use of the burner, the user
shall have qualified personnel carry out the following operations:
a Remove the power supply by disconnecting the power cord from the
mains.
b) Disconnect the fuel supply by means of the hand-operated shut-off
valve and remove the control handwheels from their spindles.
Special warnings
Make sure that the burner has, on installation, been firmly secured to
the appliance, so that the flame is generated inside the appliance
firebox.
Before the burner is started and, thereafter, at least once a year,
have qualified personnel perform the following operations:
a set the burner fuel flow rate depending on the heat input of the
appliance;
b set the flow rate of the combustion-supporting air to obtain a combu-
stion efficiency level at least equal to the lower level required by the
regulations in force;
c check the unit operation for proper combustion, to avoid any harmful
or polluting unburnt gases in excess of the limits permitted by the
regulations in force;
d make sure that control and safety devices are operating properly;
e make sure that exhaust ducts intended to discharge the products of
combustion are operating properly;
f on completion of setting and adjustment operations, make sure that
all mechanical locking devices of controls have been duly tightened;
g make sure that a copy of the burner use and maintenance instruc-
tions is available in the boiler room.
In case of a burner shut-down, reser the control box by means of the
RESET pushbutton. If a second shut-down takes place, call the
Technical Service, without trying to RESET further.
The unit shall be operated and serviced by qualified personnel only,
in compliance with the regulations in force.
3) GENERAL INSTRUCTIONS DEPENDING ON FUEL USED
3a) ELECTRICAL CONNECTION
For safety reasons the unit must be efficiently earthed and installed
as required by current safety regulations.
It is vital that all saftey requirements are met. In case of any doubt,
ask for an accurate inspection of electrics by qualified personnel,
since the manufacturer cannot be held liable for damages that may
be caused by failure to correctly earth the equipment.
Qualified personnel must inspect the system to make sure that it is
adequate to take the maximum power used by the equipment shown
on the equipment rating plate. In particular, make sure that the
system cable cross section is adequate for the power absorbed by
the unit.
No adaptors, multiple outlet sockets and/or extension cables are per-
mitted to connect the unit to the electric mains.
An omnipolar switch shall be provided for connection to mains, as
required by the current safety regulations.
The use of any power-operated component implies observance of a
few basic rules, for example:
- do not touch the unit with wet or damp parts of the body and/or with
bare feet;
- do not pull electric cables;
- do not leave the equipment exposed to weather (rain, sun, etc.)
unless expressly required to do so;
- do not allow children or inexperienced persons to use equipment;
The unit input cable shall not be replaced by the user.
In case of damage to the cable, switch off the unit and contact qualified
personnel to replace.
When the unit is out of use for some time the electric switch supplying all
the power-driven components in the system (i.e. pumps, burner, etc.)
should be switched off.
4
3b) FIRING WITH GAS, LIGHT OIL OR OTHER FUELS
GENERAL
The burner shall be installed by qualified personnel and in com-
pliance with regulations and provisions in force; wrong installation
can cause injuries to people and animals, or damage to property, for
which the manufacturer cannot be held liable.
Before installation, it is recommended that all the fuel supply system
pipes be carefully cleaned inside, to remove foreign matter that might
impair the burner operation.
Before the burner is commissioned, qualified personnel should ins-
pect the following:
a the fuel supply system, for proper sealing;
b the fuel flow rate, to make sure that it has been set based on the
firing rate required of the burner;
c the burner firing system, to make sure that it is supplied for the desi-
gned fuel type;
d the fuel supply pressure, to make sure that it is included in the range
shown on the rating plate;
e the fuel supply system, to make sure that the system dimensions are
adequate to the burner firing rate, and that the system is equipped
with all the safety and control devices required by the regulations in
force.
When the burner is to remain idle for some time, the fuel supply tap
or taps should be closed.
SPECIAL INSTRUCTIONS FOR USING GAS
Have qualified personnel inspect the installation to ensure that:
a the gas delivery line and train are in compliance with the regulations
and provisions in force;
b all gas connections are tight;
c the boiler room ventilation openings are such that they ensure the air
supply flow required by the current regulations, and in any case are
sufficient for proper combustion.
Do not use gas pipes to earth electrical equipment.
Never leave the burner connected when not in use. Always shut the
gas valve off.
In case of prolonged absence of the user, the main gas delivery
valve to the burner should be shut off.
Precautions if you can smell gas
a do not operate electric switches, the telephone, or any other item
likely to generate sparks;
b immediately open doors and windows to create an air flow to purge
the room;
c close the gas valves;
d contact qualified personnel.
Do not obstruct the ventilation openings of the room where gas
appliances are installed, to avoid dangerous conditions such as the
development of toxic or explosive mixtures.
DIRECTIVES AND STANDARDS
Gas burners
European directives:
- Directive 90/396/CEE - Gas Appliances;
- Directive 2006/95/EC on low voltage;
- Directive 2004/108/CEE on electromagnetic compatibility
Harmonised standards :
-UNI EN 676 (Gas Burners;
-CEI EN 60335-1(Household and similar electrical appliances - Safety.
Part 1: General requirements;
- EN 50165 (Electrical equipment of non-electric appliances for house-
hold and similar purposes. Safety requirements.
Light oil burners
European directives:
- Directive 2006/95/EC on low voltage;
- Directive 2004/108/CEE on electromagnetic compatibility
Harmonised standards :
-CEI EN 60335-1(Household and similar electrical appliances - Safety.
Part 1: General requirements;
- EN 50165 (Electrical equipment of non-electric appliances for house-
hold and similar purposes. Safety requirements.
National standards :
-UNI 7824: Monobloc nebulizer burners for liquid fuels. Characteristics
and test methods
Heavy oil burners
European directives:
- Directive 2006/95/EC on low voltage;
- Directive 2004/108/CEE on electromagnetic compatibility
Harmonised standards :
-CEI EN 60335-1 Household and similar electrical appliances - SafetyPart
1: General requirements;
- EN 50165 Electrical equipment of non-electric appliances for household
and similar purposes. Safety requirements.
National standards :
-UNI 7824: Monobloc nebulizer burners for liquid fuels. Characteristics
and test methods
Gas - Light oil burners
European directives:
- Directive 90/396/CEE Gas Appliances;
- Directive 2006/95/EC on low voltage;
- Directive 2004/108/CEE on electromagnetic compatibility
Harmonised standards :
-UNI EN 676 Gas Burners
-CEI EN 60335-1(Household and similar electrical appliances - Safety.
Part 1: General requirements;
- EN 50165 Electrical equipment of non-electric appliances for household
and similar purposes. Safety requirements.
National standards :
-UNI 7824: Monobloc nebulizer burners for liquid fuels. Characteristics
and test methods
Gas - Heavy oil burners
European directives:
- Directive 90/396/CEE - Gas Appliances;
- Directive 2006/95/EC on low voltage;
- Directive 2004/108/CEE on electromagnetic compatibility
Harmonised standards :
-UNI EN 676 (Gas Burners;
-CEI EN 60335-1(Household and similar electrical appliances - Safety.
Part 1: General requirements;
- EN 50165 Electrical equipment of non-electric appliances for household
and similar purposes. Safety requirements.
National standards :
-UNI 7824: Monobloc nebulizer burners for liquid fuels. Characteristics
and test methods
C.I.B. UNIGAS - M039247CA
5
Burner model identification
Burners are identified by burner type and model. Burner model identification is described as follows.
Specifications
* NOTE ON THE WORKING SERVICE: the control box automatically stops after 24h of continuous working. The control box
immediately starts up, automatically.
Type P71 Model M-. AB. S. *. A. 0. 50
(1) (2) (3) (4) (5) (6) (7) (8)
(1) BURNER TYPE P61 - P65 - P71 - P73A
(2) FUEL
M - Natural gas
(3) OPERATION
Available versions
AB - Double stage
PR - Progressive MD - Fully modulating
(4) BLAST TUBE
S - standard
L - Extended
(5) DESTINATION COUNTRY
* - see data plate
(6) BURNER VERSION
A - Standard
(7) EQUIPMENT
Available version
0 = 2 valves
1 = 2 valves + gas proving system
7 = 2 valves + high gas pressure switch
8 = 2 valves + gas proving system + high gas pressure switch
(8)GAS CONNECTION
32 = Rp11/4 40 = Rp11/2 50 = Rp2 65 = DN65 80 = DN80
BURNER TYPE P61 M-...0.xx P65 M-...0.xx
Output min. - max. kW
160 - 800 270 - 970
Fuel
Natural gas Natural gas
Category see next paragraph see next paragraph
Gas flow rate min.-max. Stm
3
/h
17 - 84.7 28.6 - 103
Gas pressure min.-max. mbar (see Note 2) (see Note 2)
Electric supply 230V 3~ / 400V 3N ~ 50Hz 230V 3~ / 400V 3N ~ 50Hz
Total power consumption kW 1.6 2
Fan motor kW 1.1 1.5
Protection IP40 IP40
Weight kg 55 - 70 60 - 80
Operation
Double stage - Progressive - Fully
modulating
Double stage - Progressive - Fully
modulating
Valves size/Gas connection - 32 1"
1/4
/ Rp1
1/
1"
1/4
/ Rp1
1/
Valves size/Gas connection - 40 1"
1/2
/ Rp1
1/2
1"
1/2
/ Rp1
1/2
Valves size/Gas connection - 50 2" / Rp2 2" / Rp2
Valves size/Gas connection - 65 2"
1/2
/ DN65 2"
1/2
/ DN65
Operating temperature C -10 +50 -10 +50
Storage TemperatureStorage Temperature C -20 +60 -20 +60
Working service* Intermittent Intermittent
Note1:
All gas flow rates are referred to Stm
3
/h (1013 mbar absolute pressure, 15 C temperature) and are valid for G20 gas
(net calorific value H
i
= 34.02 MJ/Stm
3
)
Note2: Maximum gas pressure = 360mbar (with Rp1"1/2 - 2" and Dungs MBDLE/MBC valves)
= 500mbar (with DN65/80 and Siemens VGD / Dungs MBCvalves)
Minimum gas pressure = see gas curves.
PART I: INSTALLATION MANUAL
C.I.B. UNIGAS - M039247CA
6
* NOTE ON THE WORKING SERVICE: the control box automatically stops after 24h of continuous working. The control box
immediately starts up, automatically.
Country and usefulness gas categories
BURNER TYPE
P71
M-...0.xx
P71
M-...1.xx
Output min. - max. kW
300 - 1.200 300 - 1650
Fuel
Natural gas Natural gas
Category see next paragraph see next paragraph
Gas flow rate min.-max. Stm
3
/
32 - 127 32 - 174.6
Gas pressure min.-max. mbar
(see Note 2) (see Note 2)
Electric supply
230V 3~ / 400V 3N ~ 50Hz 230V 3~ / 400V 3N ~ 50Hz
Total power consumption kW
2.7 2.7
Fan motor kW
2.2 2.2
Protection
IP40 IP40
Weight kg
80 - 115 80 - 115
Operation
Double stages - Progressive - Fully
modulating
Double stages - Progressive - Fully
modulating
Valves size/Gas connection - 40 1"
1/2
/ Rp1
1/2
1"
1/2
/ Rp1
1/2
Valves size/Gas connection - 50
2"/Rp2 2"/Rp2
Valves size/Gas connection - 65
2"
1/2
/ DN65 2"
1/2
/ DN65
Valves size/Gas connection - 80
3 / DN80 3 / DN80
Operating temperature C
-10 +50 -10 +50
Storage TemperatureStorage
Temperature
C -20 +60 -20 +60
Working service*
Intermittent Intermittent
BURNER TYPE P73A M-...1.50 P73A M-...1.65 P73A M-...1.80
Output min. - max. kW
320 - 2300
Fuel
Natural gas
Category see next paragraph
Gas flow rate min.-max. Stm
3
/h
34 - 243
Gas pressure min.-max. mbar
(see Note 2)
Electric supply
230V 3~ / 400V 3N ~ 50Hz
Total power consumption kW
3.5
Fan motor kW
3
Protection
IP40
Weight kg
90 110 120
Operation
Double stages - Progressive - Fully modulating
Valves size/Gas connection
2" / Rp2 2"
1/2
/ DN65 3 / DN80
Operating temperature C
-10 +50
Storage TemperatureStorage Temperature C
-20 +60
Working service*
Intermittent
Note1:
All gas flow rates are referred to Stm
3
/h (1013 mbar absolute pressure, 15 C temperature) and are valid for G20 gas
(net calorific value H
i
= 34.02 MJ/Stm
3
)
Note2: Maximum gas pressure = 360mbar (with Rp1"1/2 - 2" and Dungs MBDLE/MBC valves)
= 500mbar (with DN65/80 and Siemens VGD / Dungs MBCvalves)
Minimum gas pressure = see gas curves.
GAS
CATEGORY
COUNTRY
I
2H
AT ES GR SE FI IE HU IS NO CZ DK GB IT PT CY EE LV SI MT SK BG LT RO TR CH
I
2E
LU PL - - - - - - - - - - - - - - - - - - - - - - -
I
2E( R ) B
BE - - - - - - - - - - - - - - - - - - - - - - - -
I
2L
NL - - - - - - - - - - - - - - - - - - - - - - - -
I
2ELL
DE - - - - - - - - - - - - - - - - - - - - - - - -
I
2Er
FR - - - - - - - - - - - - - - - - - - - - - - - -
C
.
I
.
B
.

U
N
I
G
A
S

-

M
0
3
9
2
4
7
C
A
7
Overall dimensions (mm)
Burner: P61
*S = measure referred to burner fitted with standard blast tube
*L = measure referred to burner fitted with extended blast tube
**V measure stands for the gas filter when not built-in the gas valves (VGD or MBC valves from DN65 on).
Note: the gas proving system is an option.
Boiler recommended drilling template and burner flange
DN A(S*) A(L*) AA B(S*) B(L*) BB C CC D E F G H J K L M N O P Q R S U V** W Y Z
P61 PR - 0.32 32 1079 1169 99 343 433 314 736 298 812 500 312 184 204 210 240 344 M10 269 190 190 341 112 229 444 - 464 162 120
P61 MD - 0.32 32 1079 1169 99 343 433 314 736 298 812 500 312 184 204 210 240 344 M10 269 190 190 341 112 229 444 - 464 162 120
P61 AB - 0.32 32 1009 1099 99 343 433 314 666 298 812 500 312 184 204 210 240 344 M10 269 190 190 341 112 229 444 - 464 162 120
P61 PR - 0.40 40 1079 1169 99 343 433 314 736 298 812 500 312 184 204 210 240 344 M10 269 190 190 439 112 327 444 - 464 162 120
P61 MD - 0.40 40 1079 1169 99 343 433 314 736 298 812 500 312 184 204 210 240 344 M10 269 190 190 439 112 327 444 - 464 162 120
P61 AB - 0.40 40 1009 1099 99 343 433 314 666 298 812 500 312 184 204 210 240 344 M10 269 190 190 439 112 327 444 - 464 162 120
P61 PR - 0.50 50 1079 1169 99 343 433 314 736 298 812 500 312 184 204 210 240 344 M10 269 190 190 447 112 335 444 - 464 162 120
P61 MD - 0.50 50 1079 1169 99 343 433 314 736 298 812 500 312 184 204 210 240 344 M10 269 190 190 447 112 335 444 - 464 162 120
P61 AB - 0.50 50 1009 1099 99 343 433 314 666 298 812 500 312 184 204 210 240 344 M10 269 190 190 447 112 335 444 - 464 162 120
P61 PR - 0.65 65 1079 1169 99 343 433 314 736 298 997 685 312 184 204 250 240 420 M10 269 190 190 515 112 403 540 313 540 162 120
P61 MD - 0.65 65 1079 1169 99 343 433 314 736 298 997 685 312 184 204 250 240 420 M10 269 190 190 515 112 403 540 313 540 162 120
P61 AB - 0.65 65 1009 1099 99 343 433 314 666 298 997 685 312 184 204 250 240 420 M10 269 190 190 515 112 403 540 313 540 162 120
BB
CC
U
E F
D
G
J
Y
AA
B
L
C
A
Z
W
R S
Q
K
K
O
O
M
H
N
P
P
C
.
I
.
B
.

U
N
I
G
A
S

-

M
0
3
9
2
4
7
C
A
8
Burners: P65 - P71 - P73A
*S = measure referred to burner fitted with standard blast tube *L = measure referred to burner fitted with extended blast tube **V measure stands for the gas filter when not built-in the gas valves (VGD or MBC valves
from DN65 on).
Note: the gas proving system is an option.
Boiler recommended drilling template and burner flange
DN A(S*) A(L*) AA B(S*) B(L*) BB C CC D E F G H J K L M N Omin Omax P Q R S U V** W Y Z
P65 PR - 0.32
32 1129 1219 130 326 416 373 803 316 900 568 332 184 228 208 300 376 M10 330 216 250 233 367 130 237 465 - 531 162 155
P65 PR - 1.32
32 1129 1219 130 326 416 373 803 316 1026 694 332 184 228 208 300 376 M10 330 216 250 233 367 130 237 465 - 531 162 155
P65 AB - 0.32 32 1129 1219 130 326 416 373 733 316 900 568 332 184 228 208 300 376 M10 330 216 250 233 367 130 237 465 - 531 162 155
P65 AB - 1.32
32 1129 1219 130 326 416 373 733 316 1026 694 332 184 228 208 300 376 M10 330 216 250 233 367 130 237 465 - 531 162 155
P65 MD - 0.32
32 1129 1219 130 326 416 373 803 316 900 568 332 184 228 208 300 376 M10 330 216 250 233 367 130 237 465 - 531 162 155
P65 MD - 1.32 32 1129 1219 130 326 416 373 803 316 1026 694 332 184 228 208 300 376 M10 330 216 250 233 367 130 237 465 - 531 162 155
P65 PR - 0.40
40 1129 1219 130 326 416 373 803 316 900 568 332 184 228 208 300 376 M10 330 216 250 233 465 130 335 465 - 531 162 155
P65 PR - 1.40
40 1129 1219 130 326 416 373 803 316 1026 694 332 184 228 208 300 376 M10 330 216 250 233 465 130 335 465 - 531 162 155
P65 AB - 0.40 40 1129 1219 130 326 416 373 733 316 900 568 332 184 228 208 300 376 M10 330 216 250 233 465 130 335 465 - 531 162 155
P65 AB - 1.40 40 1129 1219 130 326 416 373 733 316 1026 694 332 184 228 208 300 376 M10 330 216 250 233 465 130 335 465 - 531 162 155
P65 MD - 0.40
40 1129 1219 130 326 416 373 803 316 900 568 332 184 228 208 300 376 M10 330 216 250 233 465 130 335 465 - 531 162 155
P65 MD - 1.40
40 1129 1219 130 326 416 373 803 316 1026 694 332 184 228 208 300 376 M10 330 216 250 233 465 130 335 465 - 531 162 155
P65 PR - 0.50 50 1129 1219 130 326 416 373 803 316 900 568 332 184 228 208 300 376 M10 330 216 250 233 465 130 335 465 - 531 162 155
P65 PR - 1.50
50 1129 1219 130 326 416 373 803 316 1026 694 332 184 228 208 300 376 M10 330 216 250 233 465 130 335 465 - 531 162 155
P65 AB - 0.50
50 1129 1219 130 326 416 373 733 316 900 568 332 184 228 208 300 376 M10 330 216 250 233 465 130 335 465 - 531 162 155
P65 AB - 1.50 50 1129 1219 130 326 416 373 733 316 1026 694 332 184 228 208 300 376 M10 330 216 250 233 465 130 335 465 - 531 162 155
P65 MD - 0.50
50 1129 1219 130 326 416 373 803 316 900 568 332 184 228 208 300 376 M10 330 216 250 233 465 130 335 465 - 531 162 155
P65 MD - 1.50
50 1129 1219 130 326 416 373 803 316 1026 694 332 184 228 208 300 376 M10 330 216 250 233 465 130 335 465 - 531 162 155
P65 PR - 0.65 65 1129 1219 130 326 416 373 803 316 998 666 332 184 228 273 300 393 M10 330 216 250 233 533 130 403 533 313 548 162 155
P65 PR - 1.65
65 1129 1219 130 326 416 373 803 316 1104 772 332 184 228 273 300 393 M10 330 216 250 233 533 130 403 533 313 548 162 155
P65 AB - 0.65
65 1129 1219 130 326 416 373 733 316 998 666 332 184 228 273 300 393 M10 330 216 250 233 533 130 403 533 313 548 162 155
P65 AB - 1.65 65 1129 1219 130 326 416 373 733 316 1104 772 332 184 228 273 300 393 M10 330 216 250 233 533 130 403 533 313 548 162 155
P65 MD - 0.65
65 1129 1219 130 326 416 373 803 316 998 666 332 184 228 273 300 393 M10 330 216 250 233 533 130 403 533 313 548 162 155
P65 MD - 1.65
65 1129 1219 130 326 416 373 803 316 1104 772 332 184 228 273 300 393 M10 330 216 250 233 533 130 403 533 313 548 162 155
K
K
O
m
a
x
.
O
m
i
n
.
O max.
O min.
P
P N
H
M
C
.
I
.
B
.

U
N
I
G
A
S

-

M
0
3
9
2
4
7
C
A
9
*S = measure referred to burner fitted with standard blast tube
*L = measure referred to burner fitted with extended blast tube
** measure V refers to gas filter dimensions, whenit is not built-in in the gas valves (i.e. VGD gas valves or MBC valves from DN65 on).
DN A(S*) A(L*) AA B(S*) B(L*) BB C CC D E F G H J K L M N Omin Omax P Q R S U V** W Y(*S) Y(*L) Z
P71 PR - 0.40
40 1188 1298 130 385 495 373 803 316 900 568 332 234 264 208 300 376 M10 330 216 250 233 457 130 327 519 x 531 198 212 155
P71 PR - 1.40
40 1188 1298 130 385 495 373 803 316 1026 694 332 234 264 208 300 376 M10 330 216 250 233 457 130 327 519 x 531 198 212 155
P71 AB - 0.40
40 1118 1228 130 385 495 373 733 316 900 568 332 234 264 208 300 376 M10 330 216 250 233 457 130 327 519 x 531 198 212 155
P71 AB - 1.40
40 1118 1228 130 385 495 373 733 316 1026 694 332 234 264 208 300 376 M10 330 216 250 233 457 130 327 519 x 531 198 212 155
P71 MD - 0.40
40 1188 1298 130 385 495 373 803 316 900 568 332 234 264 208 300 376 M10 330 216 250 233 457 130 327 519 x 531 198 212 155
P71 MD - 1.40
40 1188 1298 130 385 495 373 803 316 1026 694 332 234 264 208 300 376 M10 330 216 250 233 457 130 327 519 x 531 198 212 155
P71 PR - 0.50
50 1188 1298 130 385 495 373 803 316 900 568 332 234 264 208 300 376 M10 330 216 250 233 465 130 335 519 x 531 198 212 155
P71 PR - 1.50
50 1188 1298 130 385 495 373 803 316 1026 694 332 234 264 208 300 376 M10 330 216 250 233 465 130 335 519 x 531 198 212 155
P71 AB - 0.50
50 1118 1228 130 385 495 373 733 316 900 568 332 234 264 208 300 376 M10 330 216 250 233 465 130 335 519 x 531 198 212 155
P71 AB - 1.50
50 1118 1228 130 385 495 373 733 316 1026 694 332 234 264 208 300 376 M10 330 216 250 233 465 130 335 519 x 531 198 212 155
P71 MD - 0.50
50 1188 1298 130 385 495 373 803 316 900 568 332 234 264 208 300 376 M10 330 216 250 233 465 130 335 519 x 531 198 212 155
P71 MD - 1.50
50 1188 1298 130 385 495 373 803 316 1026 694 332 234 264 208 300 376 M10 330 216 250 233 465 130 335 519 x 531 198 212 155
P71 PR - 0.65
65 1188 1298 130 385 495 373 803 316 998 666 332 234 264 275 300 393 M10 330 216 250 233 533 130 403 565 313 548 198 212 155
P71 PR - 1.65
65 1188 1298 130 385 495 373 803 316 1104 772 332 234 264 275 300 393 M10 330 216 250 233 533 130 403 565 313 548 198 212 155
P71 AB - 0.65
65 1118 1228 130 385 495 373 733 316 998 666 332 234 264 275 300 393 M10 330 216 250 233 533 130 403 565 313 548 198 212 155
P71 AB - 1.65
65 1118 1228 130 385 495 373 733 316 1104 772 332 234 264 275 300 393 M10 330 216 250 233 533 130 403 565 313 548 198 212 155
P71 MD - 0.65
65 1188 1298 130 385 495 373 803 316 998 666 332 234 264 275 300 393 M10 330 216 250 233 533 130 403 565 313 548 198 212 155
P71 MD - 1.65
65 1188 1298 130 385 495 373 803 316 1104 772 332 234 264 275 300 393 M10 330 216 250 233 533 130 403 565 313 548 198 212 155
P71 PR - 0.80
80 1188 1298 130 385 495 373 803 316 998 666 332 234 264 275 300 407 M10 330 216 250 233 574 130 444 565 344 562 198 212 155
P71 PR - 1.80
80 1188 1298 130 385 495 373 803 316 1106 774 332 234 264 275 300 407 M10 330 216 250 233 574 130 444 565 344 562 198 212 155
P71 AB - 0.80
80 1118 1228 130 385 495 373 733 316 998 666 332 234 264 275 300 407 M10 330 216 250 233 574 130 444 565 344 562 198 212 155
P71 AB - 1.80
80 1118 1228 130 385 495 373 733 316 1106 774 332 234 264 275 300 407 M10 330 216 250 233 574 130 444 565 344 562 198 212 155
P71 MD - 0.80
80 1188 1298 130 385 495 373 803 316 998 666 332 234 264 275 300 407 M10 330 216 250 233 574 130 444 565 344 562 198 212 155
P71 MD - 1.80
80 1188 1298 130 385 495 373 803 316 1106 774 332 234 264 275 300 407 M10 330 216 250 233 574 130 444 565 344 562 198 212 155
DN A AA B BB C CC D E F G H J K L M N Omin Omax P Q R S U V W Y Z
P73A PR - 1.50
50 1303 130 500 373 803 316 1026 694 332 234 264 208 300 376 M10 330 216 250 233 465 130 335 519 x 531 212 155
P73A AB - 1.50
50 1233 130 500 373 733 316 1026 694 332 234 264 208 300 376 M10 330 216 250 233 465 130 335 519 x 531 212 155
P73A MD - 1.50
50 1303 130 500 373 803 316 1026 694 332 234 264 208 300 376 M10 330 216 250 233 465 130 335 519 x 531 212 155
P73A PR - 1.65
65 1303 130 500 373 803 316 1104 772 332 234 264 275 300 393 M10 330 216 250 233 533 130 403 565 313 548 212 155
P73A AB - 1.65
65 1233 130 500 373 733 316 1104 772 332 234 264 275 300 393 M10 330 216 250 233 533 130 403 565 313 548 212 155
P73A MD - 1.65
65 1303 130 500 373 803 316 1104 772 332 234 264 275 300 393 M10 330 216 250 233 533 130 403 565 313 548 212 155
P73A PR - 1.80
80 1303 130 500 373 803 316 1106 774 332 234 264 275 300 407 M10 330 216 250 233 574 130 444 565 344 562 212 155
P73A AB - 1.80
80 1233 130 500 373 733 316 1106 774 332 234 264 275 300 407 M10 330 216 250 233 574 130 444 565 344 562 212 155
P73A MD - 1.80
80 1303 130 500 373 803 316 1106 774 332 234 264 275 300 407 M10 330 216 250 233 574 130 444 565 344 562 212 155
C.I.B. UNIGAS - M039247CA
10
Performance curves
To get the input in kcal/h, multiply value in kW by 860.
Data are referred to standard conditions: atmospheric pressure at 1013mbar, ambient temperature at 15C.
NOTE: The performance curve is a diagram that represents the burner performance in the type approval phase or in the laboratory
tests, but does not represent the regulation range of the machine. On this diagram the maximum output point is usually reached by adj-
suting the combustion head to its MAX position (see paragraph Adjusting the combustion head); the minimum output point is rea-
ched setting the combustion head to its MIN position. During the first ignition, the combustion head is set in order to find a
compromise between the burner output and the generator specifications, that is why the minimum output may be different from the Per-
formance curve minimum.
B
A
C
K

P
R
E
S
S
U
R
E

I
N

C
O
M
B
U
S
T
I
O
N

C
H
A
M
B
E
R

m
b
a
r
P61
kW
P65
kW
B
A
C
K

P
R
E
S
S
U
R
E

I
N

C
O
M
B
U
S
T
I
O
N

C
H
A
M
B
E
R

m
b
a
r
P71M-...0.xx5
kW
P71 M-...1.xx
kW
B
A
C
K

P
R
E
S
S
U
R
E

I
N

C
O
M
B
U
S
T
I
O
N

C
H
A
M
B
E
R

m
b
a
r
P73A
kW
-2
-1
0
1
2
3
4
5
6
7
8
100 200 300 400 500 600 700 800 900
0
1
2
3
4
5
6
7
8
9
200 300 400 500 600 700 800 900 1000
-2
0
2
4
6
8
10
12
14
0 200 400 600 800 1000 1200 1400
-2
0
2
4
6
8
10
12
14
0 200 400 600 800 1000 1200 14001600 1800
0
2
4
6
8
10
12
250 500 750 1000 1250 1500 1750 2000 2250 2500
C.I.B. UNIGAS - M039247CA
11
Pressure in the network - gas flow rate curves
G
A
S

P
R
E
S
S
U
R
E

I
N
T
H
E

N
E
T
W
O
R
K

m
b
a
r
P61
Gas rate Stm
3
/h
P65
Gas rate Stm
3
/h
G
A
S

P
R
E
S
S
U
R
E

I
N
T
H
E

N
E
T
W
O
R
K

m
b
a
r
P71 M-...0.xx
Gas rate Stm
3
/h
P71 M-...1.xx
Gas rate Stm
3
/h
G
A
S

P
R
E
S
S
U
R
E

I
N
T
H
E

N
E
T
W
O
R
K

m
b
a
r
P73A M-...1.xx
Gas rate Stm
3
/h
Caution: the gas rate value is quoted on the x-axis, the related network pressure is quoted on the y-axis (pressure value in
the combustion chamber is not included). To know the minimum pressure at the gas train inlet, necessary to get the reque-
sted gas rate, add the pressure value in the combustion chamber to the value read on the y-axis.
0
10
20
30
10 20 30 40 50 60 70 80 90 100
Rp 2" (50)
DN65
Rp 1" (32)
Rp 1 (40)
0
20
40
60
80
100
120
20 30 40 50 60 70 80 90 100 110 120
Rp 2" (50)
DN65
Rp 1" (32)
Rp 1" (40)
0
10
20
30
40
20 40 60 80 100 120 140
Rp 1" (40) &
Rp 2" (50)
DN65
DN80
0
10
20
30
40
50
60
70
80
25 50 75 100 125 150 175 200
Rp 1" (40) &
Rp 2" (50)
DN65
DN80
0
25
50
75
100
125
0 50 100 150 200 250
Rp 2" (50)
DN65
DN80
C.I.B. UNIGAS - M039247CA
12
MOUNTINGS AND CONNECTIONS
Packing
Burners are despatched in cardboard packages whose dimensions are:
P61: 1200mm x 670mm x 540mm (L x P x H).
P65 - P71 - P73A: 1280mm x 850mm x 760mm (L x P x H).
Packing cases of this type are affected by humidity; the maximum number of cases to be stacked is shown outside the packing.The fol-
lowing are placed in each packing case.
burner with gas train;
gasket to be inserted between the burner and the boiler;
envelope containing this manual
To get rid of the burners packing, follow the procedures laid down by current laws on disposal of materials.
Fitting the burner to the boiler
To install the burner into the boiler, proceed as follows:
1 make a hole on the closing door of the combustion chamber as described on paragraph Overall dimensions)
2 place the burner to the boiler: lift it up and handle it according to the procedure described on paragraph Handling the burner;
3 place the 4 stud bolts (5) on boilers door, according to the burners drilling template described on paragraph Overall dimensions;
4 fasten the 4 stud bolts;
5 place the gasket on the burner flange;
6 install the burner into the boiler;
7 fix the burner to the stud bolts, by means of the fixing nuts, according to the next picture.
8 After fitting the burner to the boiler, ensure that the gap between the blast tube and the refractory lining is sealed with appropriate
insulating material (ceramic fibre cord or refractory cement).
The burner is designed to work positioned according to the picture below. For different installations, please contact the Technical
Department.
Matching the burner to the boiler
The burners described in this manual have been tested with combustion chambers that comply with EN676 regulation and whose
dimensions are described in the diagram . In case the burner must be coupled with boilers with a combustion chamber smaller in dia-
meter or shorter than those described in the diagram, please contact the supplier, to verify that a correct matching is possible, with res-
pect of the application involved. To correctly match the burner to the boiler verify the necessary input and the pressure in combustion
chamber are included in the burner performance curve; otherwise the choice of the burner must be revised consulting the burner manu-
facturer. To choose the blast tube lenght follow the instructions of the boiler manufacturer. In absence of these consider the following:
Cast-iron boilers, three pass flue boilers (with the first pass in the rear part): the blast tube must protrude no more than 100 mm into
the combustion chamber.
Pressurised boilers with flame reversal: in this case the blast tube must penetrate at least 50 - 100 mm into combustion chamber in
respect to the tube bundle plate.
Keys
1 Burner
2 Fixing nut
3 Washer
4 Sealing gasket
5 Stud bolt
7 Blast tube
SIDE UP
SIDE
DOWN
C.I.B. UNIGAS - M039247CA
13
The length of the blast tubes does not always allow this requirement to be met, and thus it may be necessary to use a suitably-sized
spacer to move the burner backwards or to design a blast tube tha suites the utilisation (please, contact the manifacturer).
Gas train connections
The next figures show the gas train components wich are included in the delivery and those wich must be fitted by the customer. The
diagram complies with regulations in force.
Fig. 4
Key
a) Heat output in kW
b) Lenght of the flame tube in meters
c) Flame tube firing intensity in MW/m
3
d) Combustion chamber diameter (m)
Fig. 4 - Firing intensity, diameter and lenght of the test flame tube as a function of the heat
input in kW.
ATTENTION: BEFORE EXECUTING THE CONNECTIONS TO THE GAS PIPE NETWORK, BE SURE THAT THE
MANUAL CUTOFF VALVES ARE CLOSED. READ CAREFULLY THE WARNINGS CHAPTER AT THE BEGINNING
OF THIS MANUAL.
Rp1 1/4 - Rp1 1/2 - Rp2: Gas train with valves group MB-DLE (2 valves + gas filter + pressure governor + pressure switch) + leakage
control VPS504
Rp2 - DN65 - DN80: Gas train with valves group VGD with built-in gas pressure governor + gas proving system VPS504
Rp2: Gas train with valves group MBC (2 valves + gas filter + pressure governor) + VPS504 gas proving system
1
2
3
4 5
7 8
9 4
MANUFACTURER INSTALLER
3
1
2
5 4
6 7 8
10
4
MANUFACTURER INSTALLER
1
2
3
4 5
7 8
18
4
MANUFACTURER INSTALLER
C.I.B. UNIGAS - M039247CA
14
*Note: the high gas pressure switch can be mounted either upstream or downstream the gas valve but upstream the butterfly gas valve
(see item no.4 in the scheme above).
Assembling the gas grain
Fig. 5 - Example of gas train
To mount the gas train, proceed as follows:
1-a)in case of threaded joints: use proper seals according to the gas used;
1-b)in case of flanged joints: place a gasket (no. 1A..1E - Fig. 5) between the elements
2) fasten all the items by means of screws, according to the next diagrams, observing the mounting direction for each item.
NOTE: the bellows unit, the manual valve and the gaskets are not part of the standard supply.
The procedures of installation fo the gas valves are showed in the next paragraphs, according to the gas train used:
threaded gas trains with Multibloc Dungs MB-DLE or MBC..SE 1200 or Siemens VGD20..
flanged gas trains with Multibloc Dungs MBC..SE 1900-3100-5000 or Siemens VGD40..
DN65 - DN80: Gas train with valves group MBC (2 valves + pressure governor) + VPS504 gas proving system
Key
1 Burner
2 Butterfly valve
3 Gas proving system
4 Maximum gas pressure switch (option*)
5 Minimum gas pressure switch
6 Gas filter
7 Bellows unit
8 Manual valve
9 MB-DLE Valves group
10 VGD Valves group
18 Valves group MBC (2, provided with filter)
19 Valves group MBC (an external filter must be installed)
ATTENTION: once the gas train is mounted according to the diagram (Fig. 5), the gas proving test mus be performed,
according to the procedure set by the laws in force.
ATTENTION: it is recommended to mount filter and gas valves to avoid that extraneous material drops inside the valves,
during maintenance and cleaning operation of the filters (both the filters outside the valves group and the ones built-in the
gas valves).
1
2
3
4
7 8
5
6
19
4
MANUFACTURER INSTALLER
1A
5
1B
4 1C
2 1D
1E
3
Keys
1A..1E Gasket
2 Gas filter
3 Gas valves group
4 Bellows unitt
5 Manual valve
direction arrows for installation
gas supply network
C.I.B. UNIGAS - M039247CA
15
MULTIBLOC DUNGS MB-DLE 405..412
Mounting
1. Mount flange onto tube lines: use appropriate sealing agent (see Fig. 8);
2. insert MB-DLE: note position of O rings (see Fig. 8);
3. tighten screws A, B, C and D (Fig. 6 - Fig. 7), accordind to the mounting positions (Fig. 9);
4. after installation, perform leakage and functional test;
5. disassembly in reverse order.
2
MULTIBLOC DUNGS MB-DLE 415..420
Mounting
1. Loosen screws A and B do not unscrew (Fig. 10 - Fig. 11).
2. unscrew screws C and D (Fig. 10 - Fig. 11).
3. Remove MultiBloc between the threaded flanges (Fig. 11).
4. After mounting, perform leakage and functional tests.
MULTIBLOC DUNGS MBC300-700-1200SE (Threaded valves group)
Fig. 6 Fig. 7 Fig. 8 Fig. 9
Fig. 10 Fig. 11 Fig. 12 Fig. 13
Mounting
1. Mount flange onto tube lines. Use appropriate sealing agent (see Fig. 14)
2. Insert MBC...SE. Note position of O rings (see Fig. 15).
3. Tighten screws A H
4. After installation, perform leakage and functional test.
5. Disassembly in reverse order
Fig. 15
A B
D C
MOUNTING POSITIONS
A
B
C
D
C
B D
A
MOUNTING POSITIONS
MOUNTING
POSITIONS
OPTION
20 16 12 8 4 pBr
20 16 1284 p Br
201612 8 4pBr
2 0 1 6 1 2 8 4p B r
min. 5 x DN
DN

20
16 12 8
4
pBr

Fig. 14
C.I.B. UNIGAS - M039247CA
16
MULTIBLOCDUNGS MBC1900-3100-5000SE (Flanged valves group)
Siemens VGD20.. and VGD40.. gas valves - with SKP2.. (pressure governor)
Mounting
When mounting the VGD.. double gas valve, two flanges are required (as for VGD20.. model, the flanges are threaded);
to prevent cuttings from falling inside the valve, first fit the flanges to the piping and then clean the associated parts;
install the valve;
the direction of gas flow must be in accordance with the direction of the arrow on the valve body;
ensure that the bolts on the flanges are properly tightened;
ensure that the connections with all components are tight;
make certain that the O-rings and gaskets between the flanges and the double gas valve are fitted.
Connect the reference gas pipe (TP in figure; 8mm-external size pipe supplied loose), to the gas pressure nipples placed on the
gas pipe, downstream the gas valves: gas pressure must be measured at a distance that must be at least 5 times the pipe size.
Leave the blowhole free (SA in figure). Should the spring fitted not permit satisfactory regulation, ask one of our service centres for a
suitable replacement.
Caution: the SKP2 diaphragm D must be vertical (see Fig. 19).
WARNING: removing the four screws BS causes the device to be unserviceable!
Mounting
1. Insert setscrews A
2. Insert seals
3. Insert setscrews B
4. Tighten setscrews A + B.
Ensure correct seating of the seal!
6. After installation, perform leakage and functional test.
7. Disassembly in reverse order.
Fig. 16
Fig. 17
Fig. 18 Fig. 19
SIEMENS VGD..MOUNTING
POSITIONS
Fig. 20
Mounting positions OPTION
10 = pulse lines
min. 5 x DN
DN

A
B
B
A
B
B
A
A
BS
BS
SKP1. SKP2.
BS
BS
SA TP
D
7631z05/0101
C.I.B. UNIGAS - M039247CA
17
Pressure adjusting range
The pressure adjusting range, downstream the gas valves group, changes according to the spring provided with the valve group.
Keys
1 spring
2 cap
DUNGS MBC valves:
Siemens VGD valves with SKP actuator :
Gas Proving System VPS504
The VPS504 check the operation of the seal of the gas shut off valves. This check, carried out as soon as the boiler thermostat gives a
start signal to the burner, creates, by means of the diaphragm pump inside it, a pressure in the test space of 20 mbar higher than the
supply pressure. To install the DUNGS VPS504 gas proving system on the MD-DLE valves group, proceed as follows:
1 turn off gas supply.;
2 Switch off power supply.
3 remove the Multibloc screw plugs (Fig. 22-A);
4 iInsert sealing rings (10,5 x 2,25) into VPS 504 (Fig. 22-B - Fig. 23)
Fig. 21
DUNGS MBC..SE Siemens SKP actuator
Performance range (mbar) 4 - 20 20 - 40 40 - 80 80 - 150
Spring colour - red black green
Performance range (mbar) 0 - 22 15 - 120 100 - 250
Spring colour neutral yellow red
TP
I
1
2
2
1
C.I.B. UNIGAS - M039247CA
18
5 Torque screws 3, 4, 5, 6 (M4 x16) Fig. 23-C
Only use screws with metric thread on reassembly (modification, repair).
6 On completion of work, perform a leak and functional test.
When wishing to monitor the test, install a pressure gauge ranged to that of the pressure supply point PA (Fig. 23). If the test cycle is
satisfactory, after a few seconds the consent light LC (yellow) comes on. In the opposite case the lockout light LB (red) comes on. To
restart it is necessary to reset the appliance by pressing the illuminated pushbutton LB.
Once the train is installed, connect the gas valves group and pressure switches plugs.
Electrical connections
Remove the cover of the burner electrical board.
Execute the electrical connections to the supply terminal board as shown in Fig. 26, check the direction of the fan motor (see rela-
ted paragraph) and refit the panel cover.
Wiring diagram keys on page 45.
Note on elecrtical supply
If the power supply to the burner is 230V three-phase or 230V
phase-phase (without a neutral), with the Siemens LME2... con-
trol box, between the terminal 2 on the board and the earth ter-
minal, an RC Siemens RC466890660 filter must be inserted.
Key
Fig. 24
C - Capacitor (22nF/250V)
LME - Siemens control box
R - Resistor (1Mohm)
Fig. 22 Fig. 23
ATTENTION: once the gas train is mounted according to the diagrams shown in the previous pages, the gas proving test
mus be performed, according to the procedure set by the laws in force.
Respect the basic safety rules. make sure of the connection to the earthing system. do not reverse the phase and
neutral connections. fit a differential thermal magnet switch adequate for connection to the mains.
ATTENTION: before executing the electrical connections, pay attention to turn the plants switch to OFF and be
sure that the burners main switch is in 0 position (OFF) too. Read carefully the chapter WARNINGS, and the
Electrical connections section.
WARNING: The burner is provided with a jumper between terminals 6 and 7; in the event of connecting the high/
low flame thermostat remove this jumper before connecting the thermostat.
IMPORTANT: while connecting electric supply wires to burners teminal block be sure that ground wire should be
longer than phase and neutral ones.
WARNING: if the cable that connects the thermostats and the control box should be longer than 3 meters, insert a
sectioning relay following the attached electrical wiring diagram.
A B
LC
LB
PA
C
C.I.B. UNIGAS - M039247CA
19
RC466890660 - RC Siemens filter
Rotation of fan motor
Once the electrical connection of the burner is executed, remember to check the rotation of the fan motor. The motor should rotate
according to the arrow symbol on the body. In the event of wrong rotation, reverse the three-phase supply and check again the rota-
tion of the motor.
NOTE: the burners are supplied for three-phase 400V supply, and in the case of three-phase 230V supply it is necessary to
modify the electrical connections into the terminal box of the electric motor and replace the overload tripped relay.
Fig. 25 - Probes connection scheme for modulating burners
Fig. 26 - Power supply terminal block
Fig. 27
CAUTION: check the motor thermal cut-out adjustment
Thermocouple
Pressure probe
Voltage signal
Current signal
Terminal block for connections
on printed circuit
C.I.B. UNIGAS - M039247CA
20
ADJUSTMENTS
Combustion head gas pressure curves depending on the flow rate
Curves are referred to pressure = 0mbar in the combustion head!
The curves referred to the gas pressure in the combustion head, depending on the gas flow rate, are referred to the burner properly
adjusted (percentage of residual O
2
in the flues as shown in the Recommended combustion values table and CO in the standard
limits). During this stage, the combustion head, the gas butterfly valve and the actuator are at the maximum opening. Refer to Fig. 28,
showing the correct way to measure the gas pressure, considering the values of pressure in combustion chamber, surveyed by means
of the pressure gauge or taken from the boilers Technical specifications.
Fig. 28
Key
1 Generator
2 Pressure outlet on the combustion chamber
3 Gas pressure outlet on the butterfly valve
4 Differential pressure gauge
Measuring the gas pressure in the combustion head
In order to measure the pressure in the combustion head, insert the pressure gauge probes: one into the combustion chambers pres-
sure outlet (Fig. 28-2) to get the pressure in the combustion chamber and the other one into the butterfly valves pressure outlet of the
burner (Fig. 28-3). On the basis of the measured differential pressure, it is possible to get the maximum flow rate: in the pressure - rate
curves (showed on the next paragraph), it is easy to find out the burners output in Stm
3
/h (quoted on the x axis) from the pressure
measured in the combustion head (quoted on the y axis). The data obtained must be considered when adjusting the gas flow rate.
NOTE: THE PRESSURE-RATE CURVES ARE GIVEN AS INFORMATION ONLY; FOR A PROPER SETTING OF THE GAS RATE,
PLEASE REFER TO THE GAS METER READING.
1
2
4
3
C.I.B. UNIGAS - M039247CA
21
Gas pressure in combustion head vs. gas flow rate curves
G
a
s

p
r
e
s
s
u
r
e

i
n
c
o
m
b
u
s
t
i
o
n

h
e
a
d
P61
Gas rate Stm
3
/h
P65
Gas rate Stm
3
/h
G
a
s

p
r
e
s
s
u
r
e

i
n
c
o
m
b
u
s
t
i
o
n

h
e
a
d
P71 M-...0.xx
Gas rate Stm
3
/h
P71 M-...1.xx
Gas rate Stm
3
/h
G
a
s

p
r
e
s
s
u
r
e

i
n
c
o
m
b
u
s
t
i
o
n

h
e
a
d
P73A M-...1.xx
Gas rate Stm
3
/h
0
2
4
6
8
10
15 25 35 45 55 65 75 85 95
2
3
4
5
6
7
8
9
10
20 30 40 50 60 70 80 90 100 110
0
2
4
6
8
30 40 50 60 70 80 90 100 110 120 130
0
2
4
6
8
10
12
30 60 90 120 150 180
0
5
10
15
20
25
30
35
0 50 100 150 200 250
C.I.B. UNIGAS - M039247CA
22
Adjusting air and gas flow rates
Startup Output
The start-up heat output shall not exceed 1/3 the operating maximum output. The minimum gas flow rate must be set in order to reach
an output value lower than 1/3 the nominal output.
Adjustments - brief description
Adjust the air and gas flow rates at the maximum output (high flame) first, by means of the air damper and the valves group pres-
sure stabiliser respectively.
Check that the combustion parameters are in the suggested limits.
Check the flow rate measuring it on the counter or, if it was not possible, verifying the combustion head pressure by means of a dif-
ferential pressure gauge, as described on par. Measuring the gas pressure in the combustion head on page 20.
Then, adjust the combustion values corresponding to the points between maximum and minimum (progressive -fully modulating
burners only): set the shape of the adjusting cam foil. The adjusting cam sets the air/gas ratio in those points, regulating the ope-
ning-closing of the air damper.
.Set, now, the low flame output, acting on the low flame microswitch of the actuator in order to avoid the low flame output increa-
sing too much or that the flues temperature gets too low to cause condensation in the chimney.
To change the burner setting during the testing in the plant, follows the next procedure, according to the model provided.
Adjusting procedure
The burner is factory-set with the combustion head at the position that refers to the "MAX" output. The maximum output setting refers to
the fully-ahead position of the combustion head. As for fully-ahead position, it means that the head is towards the boiler, fully-
backward position means that the head is towards the operator. As far as the reduced output operation, progressively move the com-
busiton head towards the MIN position, rotating clockwise the VRT screw (see picture below). The ID index shows how much the
combustion head moved.
P61 - P65 - P71
ATTENTION: before starting the burner up, be sure that the manual cutoff valves are open and check that the pres-
sure upstream the gas train complies the value quoted on paragraph Technical specifications. Be sure that the
mains switch is closed.
ATTENTION: During commissioning operations, do not let the burner operate with insufficient air flow (danger of
formation of carbon monoxide); if this should happen, make the gas decrease slowly until the normal combustion
values are achieved.
WARNING: NEVER LOOSE THE SEALED SCREWS! OTHERWISE, THE DEVICE WARRANTY WILL BE INVALIDATE!
IMPORTANT! the combustion air excess must be adjusted according to the in the following chart:
Recommended combustion parameters
Fuel Recommended (%) CO
2
Recommended (%) O
2

Natural gas 9 10 3 4.8
MAX
VRT
MIN
ID
C.I.B. UNIGAS - M039247CA
23
P73A
The burner is factory-set wih the adjusting plate holes fully open, and the combustion head at its MAX position, so it is fit to work at the
maximum output.
To adjust the gas flow, partially close the holes, as follows:
1 loosen the three V screws that fix the adjusting plate D;
2 insert a screwdriver on the adjusting plate notches and let it move CW/CCW as to open/close the holes;
3 once the adjustmet is performed, fasten the V screws.
To let the burner operate at a lower output, loose the VB screw and move progressively back the combustion head towards the MIN
position, by turning clockwise the VRT ring nut. Fasten VB screw when the adjustment is accomplished.
Attention! Change the combustion head position only if necessary. If so, repeat the air and gas adjustments described above.
DUNGS MB-DLE gas valves group: Before starting the burner up, adjust the valves group slow opening: to set the slow opening
remove cover T, reverse it upside down and use it as a toolto rotate screw VR. Decrease the ignition flow rate by screwing, increase it
by unscrewing. Do not use a screwdriver on the screw VR!
Note: the screw VSB must be removed only in case of replacemente of the coil (see picture on page 24).
On the DUNGS MBC..SE gas valves group, set the pressure regulator to 1/3 of its stroke, using a 2.5 allen key.
1 Turn the burner on by means of its main switch A: if the burner locks (LED B on in the control panel) press the RESET button (C)
on the control panel (Fig. 30). See chapter Operation for further details.
2 check the fan motor rotation (see Rotation of fan motor on page 19)
3 Start the burner up by means of the thermostat series and wait unitl the pre-purge phase comes to end and that burner starts up;
4 the burner starts up in the low flame stage: drive the burner to high flame stage, by means of the high/low flame thermostat TAB.
5 adjust the burner combustion values in the high flame stage as described in the following steps.
6 go on adjusting air and gas flow rates: check, continuosly, the flue gas analisys, as to avoid combustion with little air; dose the air
according to the gas flow rate change following the steps quoted below;
7 acting on the pressure governor of the valves group, adjust the gas flow rate in the high flame stage as to meet the values
requested by the boiler/utilisation:
- Multibloc MB-DLE: the valve is adjusted by means of the RP regulator after slackening the locking screw VB by a number of
CAUTION: perform these adjustments once the burner is turned off and cooled.
V
D
closed holes
open holes
VRT
VB
lnnensechskantschIsseI No. 2,5
AIIen key no. 2.5
CI de six pans mIe no 2,5
Chiave esagonaIe cava nr. 2,5
P
Br
Pressure setting
C.I.B. UNIGAS - M039247CA
24
turns. By unscrewing the regulator RP the valve opens, screwing the valve closes. The pressure stabilizer is adjusted by operating
the screw VS located under the cover C. By screwing down the pressure is increased and by unscrewing it is reduced. Note: the
screw VSB must be removed only in case of replacemente of the coil.
- Siemens VGD valves group: remove cap T and act on the VR adjusting screw to increase or decrease the pressure and conse-
quently the gas rate; screwind VR the rate increases, unscrewing it decreases (see next figure).
- Dungs MBC..SE valves group: act on its pressure governor to increase or decrease the pressure and consequently the gas
rate.
Pressure governor is factory-set. The setting values must be locally adapted to machine conditions. Important! Follow the instruc-
tions carefully!
8 .To adjust the air flow rate in the high flame stage, loose the RA nut and screw VRA as to get the desired air flow rate: moving
the rod T towards the air damper shaft, the air damper opens and consequently the air flow rate increases, moving it far from the
shaft the air damper closes and the air flow rate decreases.
Note: once the procedure is perfomed, be sure that the blocking nut RA is fasten.
Go on adjusting the burner according to the model (double-stage, progressive, fully-modulating).
lnnensechskantschIsseI No. 2,5
AIIen key no. 2.5
CI de six pans mIe no 2,5
Chiave esagonaIe cava nr. 2,5
P
Br
Siemens VGD..
Dungs MBC..SE
VR
T
C VS T(VR)
RP
VB
VSB
Dungs Multibloc MB-DLE
VRA
VRA
RA
TR
C.I.B. UNIGAS - M039247CA
25
Double-stage burners
9 drive the burner to the low flame stage by means of the TAB thermostat;
10 In order to change the gas flow rate slacken the nuts DB (Fig. 29) and adjust the opening angle of the gas butterfly valve by rotating
the rod TG (clockwise rotation increases gas flow, anticlockwise rotation decreases it). The slot on the butterfly valve shaft shows
the opening degree of the valve regardingthe horizontal axis (Fig. 29).
NOTE: At the end of settings, make sure the locking screws RA and DB are fully tightened.
Fig. 29
11 Now adjust the pressure switches (see page 27).
12 If it is necessary to change the burner output in the low flame stage, move the low flame cam: the low flame position matches the
ignition position. As far as burners fitted with Dungs MBC gas valves, the low flame cam does not match the ignition cam position,
that is why it must be set at about 30 more than the ignition cam.
13 Turn the burner off and then start it up again. If the adjustment is not correct, repeat the previous steps.
Berger STA12: a key is provided to move the cams.
Siemens SQN72: a key is provided to move cams I and IV, the other cams can be moved by means of screws.
On the BERGER STA12B3.41 actuator, the manual air damper control is not provided. On the Siemens actuator the AUTO/MAN mode
is provided (see picture).
Berger STA6 B 3.41 (high-low flame burners) Siemens SQN72.2A4Axx (high-low flame burners)
For DUNGS MB-DLE / Siemens VGD gas valves
Actuator camsBerger
STA
Siemens SQN72
High flame position (set to 90)
ST2 I (red)
Low flame and ignition position
ST1 III (orange)
Stand-by position (set to 0) ST0 II (blue)
Not used
MV IV (black)
For DUNGS MBCgas valves
Actuator camsBerger
STA
Siemens SQN72
High flame position (set to 90)
ST2 I (red)
Stand-by position (set to 0) ST0 III (orange)
Ignition
ST1 II (blue)
Low flame position
MV IV (black)
TG DB
MV
ST2
ST1
ST0
IV
III
II
I
AUTO/MAN
C.I.B. UNIGAS - M039247CA
26
Progressive burners
Once the procedure till step 8 described on paragraph Adjusting procedure on page 22, is accomplished, go on as follows:
9 set the low flame cam matching the high flame cam;
10 set the TAB thermostat to the minimum in order that the actuator moves progressively towards the low flame position;
The manual air damper control is not provided on these actuators. The adjustments must be carried out acting manually on the cams.
11 move the low flame cam to the minimum to move the actuator towards the low flame until the two bearings find the adjusting screw
that refers to the lower position: screw V to increase the rate, unscrew to decrease.
12 Move again the low flame cam towards the minimum to meet the next screw on the adjusting cam and repeat the previous step; go
on this way as to reach the desired low flame point.
13 Now adjust the pressure switches (see page 27).
14 If it is necessary to change the burner output in the low flame stage, move the low flame cam: the low flame position matches the
ignition position. As far as burners fitted with Dungs MBC gas valves, the low flame cam does not match the ignition cam position,
that is why it must be set at about 30 more than the ignition cam.
15 Turn the burner off and then start it up again. If the adjustment is not correct, repeat the previous steps.
Berger STA12B3.41 (progressive and fully modulating burners) Siemens SQN72.4A4Axx (progressive and fully modulating burners)
For DUNGS MB-DLE / Siemens VGD gas valves
Actuator camsBerger
STA
Siemens SQN72
High flame position (set to 90)
ST2 I (red)
Low flame and ignition position
ST1 III (orange)
Stand-by position (set to 0) ST0 II (blue)
Not used
MV IV (black)
For DUNGS MBCgas valves
Actuator camsBerger
STA
Siemens SQN72
High flame position (set to 90)
ST2 I (red)
Stand-by position (set to 0) ST0 III (orange)
Ignition
ST1 II (blue)
Low flame position
MV IV (black)
MV
ST2
ST1
ST0
IV
III
II
I
AUTO/MAN
VF
SC
SV
ID
V
SV
Gas butterfly valve closed
Gas butterfly valve open
C.I.B. UNIGAS - M039247CA
27
Fully modulating burners
Once the procedure till step 8 described on paragraph Adjusting procedure on page 22 is accomplished, go
on as follows:
To adjust the air rate in low flame and in the intermediate points, proceed as follows.
9 Keep pushed for 5 seconds the EXIT button on the modulator (Fig. 42); when the LED with the hand sym-
bol lights up, press the arrow button, driving the actuator to the maximum opening position progressively;
10 stop its stroke when it meets each screw V: adjust the air rate by adjusting the V screw that matches each
bearing.
11 Push the EXIT button to quit the manual mode.
Calibration of air and gas pressure switches
The air pressure switch locks the control box if the air pressure is not the one requested.
If it happens, unlock the burner by means of the control box unlock pushbutton, placed on
the burner control panel.
The gas pressure switches check the pressure to avoid the burner operate when the
pressure value is not in the requested pressure range.
Calibration of air pressure switch
To calibrate the air pressure switch, proceed as follows:
Remove the transparent plastic cap.
Once air and gas setting have been accomplished, startup the burner.
During the pre-purge phase o the operation, turn slowly the adjusting ring nut VR in the clockwise direction until the burner lockout,
then read the value on the pressure switch scale and set it to a value reduced by 15%.
Repeat the ignition cycle of the burner and check it runs properly.
Refit the transparent plastic cover on the pressure switch.
Calibration of low gas pressure switch
As for the gas pressure switch calibration, proceed as follows:
Be sure that the filter is clean.
Remove the transparent plastic cap.
While the burner is operating at the maximum output, test the gas pressure on the pressure port of the minimum gas pressure
switch.
Slowly close the manual cutoff valve (placed upstream the pressure switch, see gas train installation diagram), until the detected
pressure is reduced by 50%. Pay attention that the CO value in the flue gas does not increase: if the CO values are higher than the
limits laid down by law, slowly open the cutoff valve as to get values lower than these limits.
Check that the burner is operating correctly.
Clockwise turn the pressure switch adjusting ring nut (as to increase the pressure value) until the burner stops.
Slowly fully open the manual cutoff valve.
Refit the transparent plastic cover on the pressure switch.
Adjusting the high gas pressure switch (when provided)
To calibrate the high pressure switch, proceed as follows according to its mounting position:
1 remove the pressure switch plastic cover;
2 if the maximum pressure switch is mounted upstreaam the gas valves: measure the gas pressure in the network, when flame is off;
by means of the adjusting ring nut VR, set the value read, increased by the 30%.
3 if the maximum pressure switch is mounted downstream the gas governor-gas valves group and upstream the butterfly valve:
light the burner, adjust it according to the procedure in the previous paragrph. Then, measure the gas pressure at the operating
flow rate, downstream the gas governor-gas valves group and upstream the butterfly valve; by means of the adjusting ring nut
VR, set the value read on step 2, increased by the 30%;
4 replace the plastic cover.
VR
C.I.B. UNIGAS - M039247CA
28
LIMITATIONS OF USE
THE BURNER IS AN APPLIANCE DESIGNED AND CONSTRUCTED TO OPERATE ONLY AFTER BEING CORRECTLY CON-
NECTED TO A HEAT GENERATOR (E.G. BOILER, HOT AIR GENERATOR, FURNACE, ETC.), ANY OTHER USE IS TO BE CONSI-
DERED IMPROPER AND THEREFORE DANGEROUS.
THE USER MUST GUARANTEE THE CORRECT FITTING OF THE APPLIANCE, ENTRUSTING THE INSTALLATION OF IT TO
QUALIFIED PERSONNEL AND HAVING THE FIRST COMMISSIONING OF IT CARRIED OUT BY A SERVICE CENTRE AUTHORI-
SED BY THE COMPANY MANUFACTURING THE BURNER.
A FUNDAMENTAL FACTOR IN THIS RESPECT IS THE ELECTRICAL CONNECTION TO THE GENERATORS CONTROL AND
SAFETY UNITS (CONTROL THERMOSTAT, SAFETY, ETC.) WHICH GUARANTEES CORRECT AND SAFE FUNCTIONING OF
THE BURNER.
THEREFORE, ANY OPERATION OF THE APPLIANCE MUST BE PREVENTED WHICH DEPARTS FROM THE INSTALLATION
OPERATIONS OR WHICH HAPPENS AFTER TOTAL OR PARTIAL TAMPERING WITH THESE (E.G. DISCONNECTION, EVEN
PARTIAL, OF THE ELECTRICAL LEADS, OPENING THE GENERATOR DOOR, DISMANTLING OF PART OF THE BURNER).
NEVER OPEN OR DISMANTLE ANY COMPONENT OF THE MACHINE.
OPERATE ONLY THE MAIN SWITCH, WHICH THROUGH ITS EASY ACCESSIBILITY AND RAPIDITY OF OPERATION ALSO
FUNCTIONS AS AN EMERGENCY SWITCH, AND ON THE RESET BUTTON.
IN CASE OF A BURNER SHUT-DOWN, RESET THE CONTROL BOX BY MEANS OF THE RESET PUSHBUTTON. IF A SECOND
SHUT-DOWN TAKES PLACE, CALL THE TECHNICAL SERVICE, WITHOUT TRYING TO RESET FURTHER.
WARNING: DURING NORMAL OPERATION THE PARTS OF THE BURNER NEAREST TO THE GENERATOR (COUPLING
FLANGE) CAN BECOME VERY HOT, AVOID TOUCHING THEM SO AS NOT TO GET BURNT.
PART II: OPERATION
C.I.B. UNIGAS - M039247CA
29
OPERATION
Turn to the ON position the mains switch A on the burner front panel.
Check the flame control box is not in the lockout position (light B on), if necessary reset it by means of the pushbutton C (reset);
Check that the control thermostats or pressure switches enable the burner to operate.
Check the gas supply pressure is sufficient (light D on), if necessary, adjust the pressure switches.
Only burners provided with the gas proving system: the check cycle of the gas proving system starts; the end of this check is
signalled by the light of the lamp on the device. When the valves check is finished, the startup cycle of the burner begins. In the case of
a leak in a valve, the gas proving system locks and the lamp E lights. To reset the device press the device pushbutton.
The startup cycle begins, the actuator drives the air damper to the maximum opening position, the fan motor starts and the pre-pur-
gue phase begins. During the pre-purgue phase, the complete opening of the air damper is signalled by the lamp F on the frontal panel
of the electrical board.
At the end of the pre-purgue phase, the air damper goes to the ignition position, the ignition transformer turns on (signalled by the
lamp H) and few seconds later the solenoid valves EV1 and EV2 are energized (lights I and L on the front panel).
Few seconds after the opening of the valves, the ignition transformer turns off and the lamp H turns off subsequently:
Double-stage burners: the burner is on in low flame stage (light G is on); some seconds later, the high flame operation begins and the
burner switches automatically to high flame (light F is on) or remains in low flame operation, accordign to the plant requests.
Progressive and fully modulating burners - few seconds after the gas valve opening, the ignition transformer is de-energized. The
burner is in low flame operation and some seconds later, the two-stages operation begins; the burner increases or decreases its output,
directly driven by the external thermostat (progressive version) or by the modulator (P in Fig. 30, fully modulating burners only).
.ATTENTION: BEFORE STARTING THE BURNER UP, BE SURE THAT THE MANUAL CUTOFF VALVES ARE OPEN
AND CHECK THAT THE PRESSURE VALUE UPSTREAM THE GAS TRAIN MATCHES THE VALUE ON PARAGRAPH
TECHNICAL SPECIFICATIONS). CHECK THAT THE MAINS SWITCH IS CLOSED. CAREFULLY READ THE WAR-
NINGS CHAPTER.
VPS504
LC
LB
C.I.B. UNIGAS - M039247CA
30
Keys
A Main switch on-off
B Lockout indicator light
C Reset pushbutton for flame control box
D Gas pressure switch consent indicator light
E Gas proving system lockout indicator light (only on burners with gas proving system)
F High flame operation indicator light (or air damper open during pre-purgue phase)
G Low flame operation indicator light
H Ignition tranformer operation indicator light
I Valve in operation indicator light for EV2
L Valve in operation indicator light for EV1
M Indicator light for fan motor overload tripped (only three-phase burners); to reset the overload tripped, the electrical board must be opened).
P Modulator (fitted only on fully modulating burners)
Q Operation manual selector: 0) stop - 1) high flame - 2) low flame - 3) automatic
Fig. 30 - Frontal panel on the electrical board

F G H
M
B
I L D
E
C
A
P
Q
C.I.B. UNIGAS - M039247CA
31
At least once a year carry out the maintenance operations listed below. In the case of seasonal servicing, it is recommended to carry
out the maintenance at the end of each heating season; in the case of continuous operation the maintenance is carried out every 6
months.
ROUTINE MAINTENANCE
Clean and examine the gas filter cartridge, if necessary replace it (see next paragraphs).
Remove, chack and clean the combustion head (see Fig. 38)
Check the ignition electrode, clean, adjust and, if necessary, replace (see page 35)
Check the detection electrode, clean, adjust and, if necessary, replace; in case of doubt, check the detection circuit following the
diagram in Fig. 44 and Fig. 45, after turning the burner back into operation.
Clean and grease leverages and rotating parts.
Removing the filter in the MULTIBLOC DUNGS MB-DLE 405..412
Check the filter at least once a year!
Change the filter if the pressure difference between pressure connection 1 and 3 (Fig. 31-Fig. 32)is p > 10 mbar.
Change the filter if the pressure difference between pressure connection 1 and 3 (Fig. 31-Fig. 32) is twice as high compared to the last
check.
You can change the filter without removing the fitting.
1 Interrupt the gas supply closing the on-off valve.
2 Remove screws 1 4 using the Allen key n. 3 and remove filter cover 5 in Fig. 33.
3 Remove the filter 6 and replace with a new one.
4 Replace filter cover 5 and tighten screws 1 4 without using any force and fasten.
5 Perform leakage and functional test, p
max.
= 360 mbar.
6 Pay attention that dirt does not fall inside the valve.
WARNING: ALL OPERATIONS ON THE BURNER MUST BE CARRIED OUT WITH THE MAINS DISCONNECTED AND
THE FUEL MANAUL CUTOFF VALVES CLOSED!
ATTENTION: READ CAREFULLY THE WARNINGS CHAPTER AT THE BEGINNIG OF THIS MANUAL..
ATTENTION: when servicing, if it was necessary to disassemble the gas train parts, remember to execute the gas proving
test, once the gas train is reassembled, according to the procedure imposed by the law in force.
Fig. 31
Fig. 32
Fig. 33
PART III: MAINTENANCE

1
0
5 34 5 3 4
6 6

2
1
3
p
e
0
4
p
a
5
p
Br
0 3
p
e
4
p
a
6 1
5
p
Br
2
C.I.B. UNIGAS - M039247CA
32
Removing the filter in theMULTIBLOC DUNGS MB-DLE 415 - 420 B01 1 1/2 - 2
Check the filter at least once a year!
Change the filter if the pressure difference between pressure connection 1 and 2 (Fig. 34-Fig. 35) p> 10 mbar.
Change the filter if the pressure difference between pressure connection 1 and 2 (Fig. 34-Fig. 35) is twice as high compared to the last
check.
You can change the filter without removing the fitting.
1 Interrupt the gas supply closing the on-off valve.
2 Remove screws 1 6 (Fig. 36).
3 Change filter insert.
4 Re-insert filter housing, screw in screws 1 6 without using any force and fasten.
5 Perform leakage and functional test, p
max.
= 360 mbar.
6 Pay attention that dirt does not fall inside the valve.
Inspection and replacement of the MULTIBLOC DUNGS MBC..SE filter (Threaded valves group)
Fig. 34
Fig. 35
Fig. 36
Inspect the filter at least once a year.
Change the filter, if pressure value between pressure connections 1 and 2 is grea-
ther than 10 mbar.
Change the filter, if pressure value between pressure connections 1 and 2 is twice
as high compared to the last inspection.
1. Interrupt gas supply: close ball valve
2. Remove screws 1-2
3. Replace the filter insert 3
4. Screw in screws 1-2 without use force to fasten.
5. Perform leakage and funcion test.
6. Pay attention that dirt does not fall inside the valve.
Space requirements for fitting filter, A: from 150 to 230 mm.
Fig. 37
2 3 4 23 4
1
5 5
0
1
3
p
e
0
4
p
a
5
p
Br
0 3
p
e
4
p
a
6 1
5
p
Br
2
B
A
C
D
E
C.I.B. UNIGAS - M039247CA
33
Gas filter maintenance
To clean or remove the filter, proceed as follows:
1 remove the cap unscrewing the fixing screws (A);
2 remove the filtering cartridge (B), clean it using water and soap, blow it with compressed air(or replace it, if necessary)
3 replace the cartridge in its proper position taking care to place it inbetween the guides as not to hamper the cap replacement;
4 be sure to replace the O ring into its place (C) and replace the cover fastening by the proper screws (A).
Removing the combustion head
To remove the combustion head, pull it out. Once removed, check that the air and gas holes are not obstructed. Clean the combustion
head by means of compressed air or scrape off the scale using a metallic brush.
Adjusting the electrodes
Important Note: Check the ignition and detection electrodes after removing/adjusting the combustion head.
ATTENTION: Before opening the filter, close the manual cutoff valve downstream the filter and bleed the gas; check that
inside the filter there is no pressurised gas.
A
B C
Type P61
Remove cover C.
Unscrew the two screws S holding in position
the washer and then unscrew VRT to free the
threaded rod AR.
Unscrew the screws V holding in position the
manifold G and pull out the complete group as
shown in figure.
Note: for the subsequent assembly carry out the
above described operations in the reverse order,
checking the correct position of the OR ring.
Fig. 38
Type P65 / P71 / P73A
Remove the lid C.
Unscrew the screws V holding in position the
manifold G and pull out the complete group as
shown in figure.
Note: for the subsequent assembly carry out the
above described operations in the reverse order,
checking the correct position of the OR ring.
Fig. 39
ATTENTION: avoid the ignition and detection electrodes to contact metallic parts (blast tube, head, etc.), otherwise the boi-
ler operation would be compromised. Check the electrodes position after any intervention on the combustion head.
OR
V G
VRT
S
AR
C
OR
V G C
VRT
AR
C.I.B. UNIGAS - M039247CA
34
- Electrodes position settings (P61 / P65 / P71)
Electrodes position settings - P73A
Replacing the electrodes
P61 / P65 / P71
Fig. 42
ATTENTION: avoid the ignition and detection electrodes to contact metallic parts (blast tube, head, etc.), otherwise the boi-
lers operation would be compromised. Check the electrodes position after any intervention on the combustion head.
Detection electrode
Earth electrode
Ignition electrode
Fig. 40
30
427
397
5

6
m
m
2
0
1
9

m
m
Fig. 41
VB
C.I.B. UNIGAS - M039247CA
35
P73A
Fig. 43
Checking the detection current
Seasonal stop
To stop the burner in the seasonal stop, proceed as follows:
1 turn the burner main switch to 0 (Off position)
2 disconnect the power mains
3 close the fuel valve of the supply line
Burner disposal
In case of disposal, follow the instructions according to the laws in force in your country about the Disposal of materials.
To measure the detection signals refer to the diagrams in Fig. 44
and Fig. 45. If the signal is less than the indicated value, check
the position of the detection electrode, the electrical contacts and
if necessary replace the detection electrode.
Fig. 44
Test point on burners fitted with printed circuit
To check the detection current, remove the jumper between termi-
nals and connect the microamperemeter (see Fig. 45).
Fig. 45
VB
Control box
Minimum detection signal
Siemens LME21-22 3 A
27
SCALE A DC
Connector
TERMINAL BOARD
MC
C
.
I
.
B
.

U
N
I
G
A
S

-

M
0
3
9
2
4
7
C
A
3
6
TROUBLESHOOTING
l = with any control box;
s= with only LGB2../LMG2../LME11/LME2..
(*) In such cases, insert the circuit SIEMENS RC466890660 ()See chapter Electrical connections)
CAUSE
TROUBLE
T
H
E

B
U
R
N
E
R

D
O
E
S
N

T
S
T
A
R
T
C
O
N
T
I
N
U
E

W
I
T
H

P
R
E
-
P
U
R
G
E
D
O
E
S
N

T

S
T
A
R
T

A
N
D

L
O
C
K
-
O
U
T
D
O
E
S
N

T

S
T
A
R
T

A
N
D

R
E
P
E
A
T
S

T
H
E

C
Y
C
L
E
S
T
A
R
T
S

A
N
D

R
E
P
E
A
T
S

T
H
E

C
Y
C
L
E
S
T
A
R
T
S

A
N
D

L
O
C
K
-
O
U
T

T
H
E

F
L
A
M
E

M
O
N
I
T
O
R

D
E
V
I
C
E

D
O
E
S
N

T

G
I
V
E
C
O
N
S
E
N
T

T
O

S
T
A
R
T
D
O
E
S
E
N

T

S
W
I
T
C
H

T
O

H
I
G
H

F
L
A
M
E
D
O
E
S
E
N

T

R
E
T
U
R
N

I
N

L
O
W

F
L
A
M
E
H
E

S
E
R
V
O

C
O
N
T
R
O
L

I
S

L
O
C
K

A
N
D

V
I
B
R
A
T
E
L
O
C
K
-
O
U
T

D
U
R
I
N
G

O
P
E
R
A
T
I
O
N
T
U
R
N
S

O
F

A
N
D

R
E
P
E
A
T
S

C
Y
C
L
E

D
U
R
I
N
G

O
P
E
R
A
T
I
O
N
MAIN SWITCH OPEN
LACK OF GAS
MAXIMUM GAS PRESSURE SWITCH DEFECTIVE (IF
PROVIDED)

THERMOSTATS/PRESSURE SWITCHES DEFECTIVE
OVERLOAD TRIPPED INTERVENTION
AUXILIARIES FUSE INTERRUPTED
CONTROL BOX FAULTY
DEFECTIVE SERVOCONTROL (IF PROVIDED)
AIR PRESSURE SWITCH FAULT OR BAD SETTING
MINIMUM GAS PRESSURE SWITCH DEFECTIVE OR GAS
FILTER DIRTY

IGNITION TRANSFORMER FAULT
IGNITION ELECTRODES BAD POSITION
DETECTION ELECTRODE BAD POSITION
BUTTERFLY VALVE BAD SETTING
DEFECTIVE GAS GOVERNOR
GAS VALVE DEFECTIVE
BAD CONNECTION OR DEFECTIVE HIGH/LOW FLAME
THERMOSTAT OR PRESSURE SWITCH (IF PROVIDED)

WRONG SETTING SERVO CONTROL CAM l l l
UV PROBE DIRTY OR DEFECTIVE (IF PROVIDED) l l l
PHASE-NEUTRAL INVERTED s
PHASE-PHASE SUPPLY OR PRESENCE OF VOLTAGE ON
THE NEUTRAL CONDUCTOR(*)
s
C.I.B. UNIGAS - M039247CA
37
SPARE PARTS
*(option)
L** = extended blast tube - S** = standard blast tube
NOTE: it is recommended to mention the burner ID number on the spare parts request form.
DESCRIPTION P61 P65 P71 P73A
CONTROL BOX - SIEMENS LME 2020468 2020468 2020468 2020468
IGNITION ELECTRODE 2080202 2080202 2080207 2080278
GROUND ELECTRODE 2080234 2080234 2080107 2080114
DETECTION ELECTRODE 2080102 2080102 2080234 -
GAS FILTER - DN65 2090117 2090117 2090117 2090117
GAS FILTER - DN80 - 2090118 2090118 2090118
GASKET 2110013 2110033 2110033 2110033
FAN WHEEL 2150044 2150038 2150038 2150068
AIR PRESSURE SWITCH 2160065 2160065 2160065 2160065
GAS PRESSURE SWITCH - DUNGS GW50 A5 2160076 2160076 2160076 2160076
GAS PRESSURE SWITCH - DUNGS GW150 A5 2160077 2160077 2160077 2160077
IGNITION TRANSFORMER 2170128 2170128 2170128 2170128
MOTOR 218025501 218020301 218021101 218025601
GAS PROVING SYSTEM 2191604* 2191604* 2191604 2191604
VALVE GROUP - Rp11/4 - DUNGS MB-DLE412 2190342 2190342 - -
VALVE GROUP - Rp11/2 - DUNGS MB-DLE415 21903L3 21903L3 21903L3 -
VALVE GROUP - Rp2 - DUNGS MB-DLE420 21903L4 21903L4 21903L4 21903N2
VALVE GROUP - DN65 - SIEMENS VGD40 2190172 2190172 2190172 2190172
VALVE GROUP - DN80 - SIEMENS VGD40 - 2190169 2190169 2190169
VALVE ACTUATOR SKP15 2190181 2190181 2190181 2190181
VALVE ACTUATOR SKP25 2190183 2190183 2190183 2190183
ACTUATOR (double stage) - BERGER STA 2480042 2480042 2480042 2480042
ACTUATOR (progressive and fully-modulating) - BERGER STA 2480053 2480053 2480053 2480053
ACTUATOR (double stage) - SIEMENS SQN72 24800A3 24800A3 24800A3 24800A3
ACTUATOR (progressive and fully-modulating) - SIEMENS SQN72 24800A4 24800A4 24800A4 24800A4
BURNER MODULATOR (Only Fully-mod. burners) 2570112 2570112 2570112 2570112
COMBUSTION HEAD 3060078 30600C2 3060080 30600L9
BLAST TUBE S** 30900L7 30900L9 30900L6 30910P8
BLAST TUBE L** 30900L8 30900M0 30910P7 -
AIR PRESSURE SWITCH ASS.Y 3500104 3500104 3500104 3500104
COMBUSTION HEAD ASS.Y(S**) 3501805 3501806 3501807 -
COMBUSTION HEAD ASS.Y(L**) 3501805 3501806 3501808 -
IGNITION CABLE 6050108 6050108 6050108 6050108
DETECTION CABLE 6050205 6050205 6050205 6050205
PRINTED CIRCUIT BOARD 6100550 6100550 6100550 6100550
C
.
I
.
B
.

U
N
I
G
A
S

-

M
0
3
9
2
4
7
C
A
3
8
BURNER EXPLODED VIEW
P61 - P65 - P71
Pos. Description Pos. Description
1.1 FAN 11.2.4 TRANSMISSION AIR ADJUSTING CAM
1.2 MOTOR 11.2.5 CONNECTING ROD
2.1 VALVE GROUP 11.2.6 ROD
2.2 THREADED PIPE 11.2.7 JOINT
2.3 ELBOW 11.2.8 ROD JOINT
2.4 M/F REDUCTION 11.3 INDEX PLATE
2.5 VALVE GROUP FLANGE 11.4 INNER AIR DAMPER
2.6 GAS PROVING SYSTEM 11.5 INDEX BUSH
3 AIR INLET 11.6 BUSH
4 HOUSING 11.7 BOX
4.1 COVER 11.8 DAMPER PIVOT
5 GASKET 11.9 BUTTERFLY TRANSMISSION PIVOT
6 AIR PRESSURE SWITCH PIPE 11.10 ACTUATOR PIVOT
7 PLEXYGLASS 11.11 CONNECTING ROD
8 BLAST TUBE 11.12 ROD
9 AIR PRESSURE SWITCH 11.13 ROD
10.1 OR RING 11.14 JOINT
10.2 BUTTERFLY VALVE 11.15 ROD JOINT
10.3 GAS MANIFOLDC 12 PREMOUNTED HEAD ADJUSTING SCREWS
11.1.1 COMPLETE MOUNTED LEVERAGE 13.1 FRONT PANEL
11.1.2 ADJUSTING CAM 13.2 CONTROL PANEL
11.1.3 ACTUATOR 13.3 CONTROL PANEL COVER
11.1.4 ACTUATOR CONNECTOR 14.1 DETECTION ELECTRODE
11.1.5 BRACKET 14.2 IGNITION ELECTRODE
11.2.1 AIR ADJUSTING CAM REGULATING NUT 14.3 GROUNDED ELECTRODE
11.2.2 AIR ADJUSTING CAM SCREW 14.4 COMBUSTION HEAD
11.2.3 AIR ADJUSTING CAM REGULATING SCREW 15 BLACK/GREEN CONNECTOR
C
.
I
.
B
.

U
N
I
G
A
S

-

M
0
3
9
2
4
7
C
A
3
9

C
.
I
.
B
.

U
N
I
G
A
S

-

M
0
3
9
2
4
7
C
A
4
0
P73A
POS. DESCRIPTION POS. DESCRIPTION
1 STANDARD BLAST TUBE 11.2.5 JOINT
2.1 FAN WHEEL 11.2.6 JOINT
2.2 MOTOR 11.3 AIR INTAKE DAMPER
3.1 GAS FILTER 11.4 AIR INTAKE DAMPER
3.2 FLANGE 11.5 AIR INTAKE
3.3 FLANGED PIPE 11.6 LOUVER SHAFT
3.4.1 GAS PRESSURE 11.7 LOUVER SHAFT
3.4.2 GAS VALVE HOUSING 11.8 LEVERAGE
3.4.3 "SKP" ACTUATOR 11.9 ROD
3.4.4 "SKP" ACTUATOR 11.10 ROD
3.4.5 GAS PROVING SYSTEM 11.11 JOINT
4 AIR INLET CONE 11.12 JOINT
5 BURNER HOUSING 12 HEAD ADJUSTING RING NUT
5.1 COVER 13.1 BOARD
6 GENERATOR GASKET 13.2.1 LIGHT
7 AIR PRESSURE SWITCH PIPE 13.2.2 LIGHT
8 INSPECTION GLASS 13.2.3 LOCK-OUT RESET BUTTON
9 BUTTERFLY GAS VALVE 13.2.4 PROTECTION
10 AIR PRESSURE SWITCH 13.2.5 SWITCH
11.1.1 LEVERAGE 13.2.6 FUSE
11.1.2 ADJUSTING CAM 13.2.7 FRONT CONTROL PANEL
11.1.3 ACTUATOR 13.3 COVER
11.1.4 ACTUATOR SHAFT 14.1 STANDARD COMBUSTION HEAD
11.1.5 BRACKET 14.2.1 IGNITION ELECTRODE
11.2.1 SCREW 14.2.2 NOZZLE HOLDER
11.2.2 CAM 14.3 DETECTION ELECTRODE
11.2.3 LEVERAGE 14.4 GAS MANIFOLD
11.2.4 ROD 15 CONNECTOR
C
.
I
.
B
.

U
N
I
G
A
S

-

M
0
3
9
2
4
7
C
A
4
1
C
.
I
.
B
.

U
N
I
G
A
S

-

M
0
3
9
2
4
7
C
A
4
2
WIRING DIAGRAMS
ATTENTION:
1 - Power supply: 400V 50Hz 3N a.c.three-phase and 230V 50Hz 1N a.c. monophase
2 - Dont reverse phase and neutral
3 - Ensure the burner is properly earthed
Burners provided with Dungs MBC valves: diagram SE18-164
Burners provided with Dungs MB-DLE or Siemens VGD valves: diagram SE18-165
SIEMENS LME11/21/22 CONTROL BOX
The series of equipment LME.. is used for the starup and supervisione of
1- or 2- stage gas burners. The series LME.. is interchangeable with the
series LGB.. and LMG.., all diagrams and accessories are interchangea-
ble.
Comparative table
Preconditions for burner startup
Burner control must be reset
All contacts in the line are closed, request for heat
No undervoltage
Air pressure switch LP must be in its no-load position
Fan motor or AGK25 is closed
Flame detector is darkened and there is no extraneous light
Undervoltage
Safety shutdown from the operating position takes place should mains
voltage drop below about AC 175 V (at UN = AC 230 V)
Restart is initiated when mains voltage exceeds about AC 185 V (at UN =
AC 230 V).
Controlled intermittent operation
After no more than 24 hours of continuous operation, the burner control
will initiate automatic controlled shutdown followed by a restart.
Reversed polarity protection with ionization
If the connections of live conductor (terminal 12) and neutral conductor
(terminal 2) aremixed up, the burner control will initiate lockout at the end
of the safety time TSA.
Control sequence in the event of fault
If lockout occurs, the outputs for the fuel valves, the burner motor and the
ignition equipment will immediately be deactivated (< 1 second).
Operational status indication
In normal operation, the different operating states are showed by means
of the multicolor LED, inside the lockout reset button:
During startup, status indication takes place according to the table:
START-UP PROGRAM
As far as the startup program, see its time diagram:
A Start command (switching on)
This command is triggered by control thermostat / pressure controller
R. Terminal 12 receives voltage and the programming mechanism
starts running. On completion of waiting time tw with the LME21..., or
after air damper SA has reached the nominal load position (on comple-
tion of t11) with the LME22..., fan motor M will be started.
tw Waiting time
During the waiting time, air pressure monitor LP and flame relay FR
are tested for correct contact positions.
t11 Programmed opening time for actuator SA
(Only with LME22...) The air damper opens until the nominal load position
is reached. Only then will fan motor M be switched on.
t10 Specified time for air pressure signal
On completion of this period of time, the set air pressure must have built
up, or else lockout will occur.
t1 Prepurge time
Purging the combustion chamber and the secondary heating surfaces:
required with low-fire air volumes when using the LME21... and with nomi-
nal load air volumes when using the LME22.... The diagrams show the so-
called prepurge time t1 during which air pressure monitor LP must
indicate that the required air pressure is available. The effective prepurge
time t1 comprises interval end tw through t3.
t12 Programmed closing time for actuator SA
(Only with LME22...)During t12, the air damper travels to the low-fire
position.
t3 Preignition time
During t3 and up to the end of TSA, flame relay FR is forced to
close. On completion of t3, the release of fuel is triggered at terminal 4.
TSA Ignition safety time
On completion of TSA, a flame signal must be present at terminal 1.
That flame signal must be continuously available until shutdown occurs,
or else flame relay FR will be deenergized, resulting in lockout.
t4 Interval BV1 and BV2-LR
Time between the end of TSA and the signal to the second fuel valve BV2
or to the load controller LR
B - B' Interval for flame establishment
C Burner operation position
C - D Burner operation (heat production)
D Controlled by "R" shutdown
The burner stops and the control device is ready for a new startup.
LGB Series LMG Series LME Series
--- LMG 25.33 LME 11.33
LGB 21.33 LMG 21.33 LME 21.33
LGB 22.33 LMG 22.33 LME 22.33
red LED
yellow LED
green LED
Steady on
Off
Status Color code Color
Waiting time tw, other
waiting states
Off
Ignition phase, ignition
controlled
Flashing yellow
Operation, flame ok Green
Operation, flame not
ok
Flashing green
Extraneous light on
burner startup
Green - red
Undervoltage Yellow - red
Fault, alarm Red
Error code output
(refer to Error code
table)
Flashing red
APPENDIX
LED
Y
........
...
.....................................

......................................



.....................................

LME11 control sequence
LME22 control sequence
LME21 control sequence
Control sequence
tw Waiting time
t1 Purge time
TSA Ignition safety time
t3 Preignition time
t3n Postignition time
t4 Interval between BV1 and BV2/LR
t10 Specified time for air pressure signal
t11 Programmed opening time for actuator SA
t12 Programmed closing time for actuator SA
SB / R
W / GP
AL
M
LP
BV1
Z
FS
tw t1 t3n
TSA
t4
7
t10
EK2
12
10
3
7
4
6
1
8
t3
A B B C D
11
SB / R
W / GP
AL
LP
SA
BV1
(LR) BV2
Z
FS
tw t1 t3n
TSA
t4
7101d02/0606
t11
t12
EK2
12
10
3
7
4
5
6
1
8
A B B C D
9
t3
t10
LK
M
I
11
SB / R
W / GP
AL
LP
BV1
(LR) BV2
Z
FS
tw t1 t3n t4
7101d05/0206
12
10
3
7
4
5
6
1
A B B C D
t3 t10
M
11
LME11 connection diagram
LME21 connection diagram
Connection diagram
AL Error message (alarm)
BV Fuel valve
EK2 Remote lockout reset button
FS Flame signal
GP Gas pressure switch
LP Air pressure switch
LR Load controller
M Fan motor
R Control thermostat/pressurestat
SB Safety limit thermostat
W Limit thermostat /pressure switch
Z Ignition transformer
LME22 connection diagram
NT
C control
RESET
EK
FSV
ION
1 2 3
M
4
BV1
5 7
Z
10
AL
T
12
R / W
GP
STB
9
7101 24 /0606
p
a
6
LP
8
EK
11
K1
K2/1 K3 K2/2
H
Si
L
N
NT
RESET
EK
FSV
ION
1 2 3
M
4
BV1
5
BV2
7
Z
10
AL
T
12
R / W
GP
STB
9
p
a
6
LP
8
EK
11
K1
K2/1 K3 K4 K2/2
H
Si
L
N
C control
NT
C control
RESET
EK
FSV
ION
1 2 3
M
4
BV1
5
BV2
7
Z
10
AL
T
12
R / W
GP
STB
9
p
a
6
LP
8
EK
11
K1
K2/1 K3 K4 K2/2
H
Si
SA
L
N
QRC
br bl sw
1 2 12
Nur LME23...
CONTROL PROGRAM IN THE EVENT OF FAULT
If a fault occurs, all outputs will immediately be deactivated (in less
than 1s).
After an interruption of power, a restart will be made with the full pro-
gram sequence.
If the operating voltage drops below the undervoltage thresold, a
safety shutdown is performed.
If the operating voltage exceeds the undervoltage thresold, a restart
will be performed.
In case of extraneous light during t1, a lockout occurs.
In case of extraneous light during tw, there is a prevention of startup
and a lockout after 30 seconds.
In case of no flame at the end of TSA, there will be max. 3 repetitions
of the startup cycle, followed by a lockout at the end of TSA, for mod.
LME11..; directly a lockout at the end of TSA for LME21-22 models.
For LME11 model: if a loss of flame occurs during operation, in case of
an establishment of flame at the end of TSA, there will be max. 3 repeti-
tions, otherwise a lockout will occur.
For LME21-22 models: if a loss of flame occurs during operation, there
will be a lockout.
If the contact of air pressure monitor LP is in working position, a pre-
vention of startup and lockout after 65 seconds will occur.
IIf the contact of air pressure monitor LP is in normal position, a
lockout occurs at the end of t10.
If no air pressure signal is present after completion of t1, a lockout will
occur.
CONTROL BOX LOCKED
In the event of lockout, the LME.. remains locked and the red signal lamp
(LED) will light up.The burner control can immediately be reset. This state
is also mantained in the case fo mains failure.
DIAGNOSITICS OF THE CASUE OF FAULT
Press the lockout reset button for more than 3 seconds to activate the
visual diagnostics.
Count the number of blinks of the red signsl lamp and check the fault
condition on the Error code table (the device repeats the blinks for
regular intervals).
During diagnostics, the control outputs are deactivated:
- the burner remains shut down;
- external fault indication is deactivated;
- fault status is showed by the red LED, inside the LMEs lockout reset
button according to the Error code table:
RESETTING THE BURNER CONTROL
When lockout occurs, the burner control can immediately be reset, by
pressing the lockout reset button for about 1..3 seconds. The LME.. can
only be reset when all contacts in the line are closed and when there is no
undervoltage.
LIMITATION OF REPETITIONS (only for LME11.. model)
If no flame is established at the end of TSA, or if the flame is lost during
operation, a maximum of 3 repetitions per controller startup can be perfor-
med via R, otherwise lockout will be initiated. Counting of repetitions is
restarted each time a controlled startup via R takes place.
Condensation, formation of ice and ingress of water are not
permitted!
TECHNICAL CHARACTERISTICS
Mains voltage 120V AC +10% / -15%
230V AC +10% / -15%
Frequency 50 ... 60 Hz +/- 6%
Power consumption 12VA
External primary fuse max. 10 A (slow)
input current at terminal 12 max. 5 A
Detection cable length max. 3m (for electrode)
Detection cable length max. 20 m (laid separately, for QRA probe)
Reset cable length max. 20 m (posato separatamente)
Term. 8 & 10 cable length max. 20 m
Thermostat cable length max. 3 m
and other terminals
Safety class I
Index of protection IP40 (to be ensured during mounting)
Operating conditions -20... +60 C, < 95% UR
Storage conditions -20... +60 C, < 95% UR
Weight approx. 160 g


ERROR CODE TABLE
2 blinks ** No establishment of flame at the end of TSA
- Faulty or soiled fuel valves
- Faulty or soiled flame detector
- Inadequate adjustement of burner, no fuel
- Faulty ignition equipment
3 blinks ***
The air pressure switch does not switch or remains in idle position:
- LP is faulty
- Loss of air pressure signal after t10
- LPis welded in normal position.
4 blinks **** - Extraneous light when burner starts up.
5 blinks ***** - LP is working position.
6 blinks ***** Free.
7 blinks ******* Loss of flame during operation
- Faulty or soiled fuel valves
- Faulty or soiled flame detector
- Inadequate adjustement of burner
8 9 blinks Free
10 blinks ********** Faulty output contacts
Attention: lockout remote signal (terminal no. 10) not enabled
- Wiring error
- Anomalous voltage on ouput terminals
- Other faults
14 blinks ************** (only for LME4x) - CPI contact (gas valve microswitch) not closed.
Note: Specifications and and data subject to change. Errors and omissions excepted.
C.I.B. UNIGAS S.p.A.
Via L.Galvani, 9 - 35011 Campodarsego (PD) - ITALY
Tel. +39 049 9200944 - Fax +39 049 9200945/9201269
web site: www.cibunigas.it - e-mail: cibunigas@cibunigas.it

You might also like