MAN B&W 98-50 ME/ME-C Engine Selection Guide 198 75 47-3.

1
This book describes the general technical features of the ME Programme.
This Engine Selection Guide is intended as a tool for assistance in the initial stages of a project.
The information is to be considered as preliminary. For further information see the Project Guide for the
relevant engine type.
It should be noted that all gures, values, measurements or information about performance stated in this
project guide are for guidance only and should not be used for detailed design purposes or as a substi-
tute for specic drawings and instructions prepared for such purposes.
Data updates
Data not nally calculated at the time of issue is marked Available on request. Such data may be made
available at a later date, however, for a specic project the data can be requested. Pages and table entries
marked Not applicable represent an option, function or selection which is not valid.
The latest, most current version of the individual Project Guide sections are available on the Internet at:
www.mandieselturbo.com under Products Marine Engines & Systems Low Speed.
Extent of Delivery
As differences may appear in the individual suppliers extent of delivery, please contact the relevant engine
supplier for a conrmation of the actual execution and extent of delivery.
In order to facilitate negotiations between the yard, the engine maker and the customer, Extent of Delivery
forms are available in which the basic and the optional executions are specied.
Electronic versions
This Project Guide book and the Extent of Delivery forms are available on a DVD and can also be found
on the Internet at: www.mandieselturbo.com under Products Marine Engines & Systems Low
Speed, where they can be downloaded.
1st Edition
June 2010
MAN B&W 98-50 ME/ME-C-TII Type Engines
Engine Selection Guide
Electronically Controlled
Twostroke Engines
MAN B&W 98-50 ME/ME-C Engine Selection Guide 198 75 47-3.1
All data provided in this document is non-binding. This data serves informational purposes only and is espe-
cially not guaranteed in any way.
Depending on the subsequent specifc individual projects, the relevant data may be subject to changes and will
be assessed and determined individually for each project. This will depend on the particular characteristics of
each individual project, especially specifc site and operational conditions.
If this document is delivered in another language than English and doubts arise concerning the translation, the
English text shall prevail.
MAN Diesel & Turbo
Teglholmsgade 41
DK2450 Copenhagen SV
Denmark
Telephone +45 33 85 11 00
Telefax +45 33 85 10 30
mandiesel-cph@mandiesel.com
www.mandieselturbo.com
Copyright 2010 MAN Diesel & Turbo, branch of MAN Diesel & Turbo SE, Germany, registered with the Danish
Commerce and Companies Agency under CVR Nr.: 31611792, (herein referred to as MAN Diesel & Turbo).
This document is the product and property of MAN Diesel & Turbo and is protected by applicable copyright laws.
Subject to modication in the interest of technical progress. Reproduction permitted provided source is given.
7010-0002-00ppr Jun 2010
MAN B&W
MAN Diesel
Engine Design ........................................................................ 1
Engine Layout and Load Diagrams, SFOC .............................. 2
Turbocharger Selection & Exhaust Gas By-pass .................... 3
Electricity Production ............................................................ 4
Installation Aspects ................................................................ 5
List of Capacities: Pumps, Coolers & Exhaust Gas ................. 6
Fuel ...................................................................................... 7
Lubricating Oil ...................................................................... 8
Cylinder Lubrication .............................................................. 9
Piston Rod Stufng Box Drain Oil .......................................... 10
Central Cooling Water System ............................................... 11
Seawater Cooling .................................................................. 12
Starting and Control Air ......................................................... 13
Scavenge Air ......................................................................... 14
Exhaust Gas .......................................................................... 15
Engine Control System .......................................................... 16
Vibration Aspects .................................................................. 17
Appendix .............................................................................. A
Contents
MAN B&W 98-50 ME/ME-C Engine Selection Guide
MAN B&W Contents
Chapter Section
MAN Diesel
1 Engine Design
The ME Tier II Engine 1.01 1987469-4.0
Engine type designation 1.02 1983824-3.6
Power, Speed, Dimensions 1.03 1985914-1.3
Engine power range and fuel oil consumption 1.04 1984634-3.4
Performance curves 1.05 1985331-6.2
ME Engine description 1.06 1984613-9.5
Engine cross section, referral to PG 1.07 1985886-4.0

2 Engine Layout and Load Diagrams, SFOC
Engine layout and load diagrams 2.01 1983833-8.4
Propeller diameter and pitch, inuence on optimum propeller speed 2.02 1983878-2.5
Layout diagram sizes 2.03 1986911-0.1
Engine layout and load diagrams, ME/ME-C/ME-GI/ME-B engines 2.04 1986993-5.1
Diagram for actual project 2.05 1986908-7.1
Specic fuel oil consumption, ME versus MC engines 2.06 1983836-3.3
SFOC for high efciency turbochargers 2.07 1987017-7.0
SFOC, reference conditions and guarantee 2.08 1987045-2.1
Examples of graphic calculation of SFOC 2.08 1987020-0.0
SFOC calculations 2.09 1986980-3.1
SFOC calculations, example 2.10 1986967-3.0
Fuel consumption at an arbitrary load 2.11 1983843-4.4
Emission control 2.12 1987540-0.2

3 Turbocharger Selection& Exhaust Gas By-pass
Turbocharger selection 3.01 1987618-1.1
Exhaust gas by-pass 3.02 1985895-9.0
NOx Reduction by SCR 3.03 1985894-7.2

4 Electricity Production
Electricity production 4.01 1985911-6.1
Designation of PTO 4.01 1984286-7.5
PTO/RCF 4.01 1984300-0.2
Space requirements for side mounted PTO/RCF for
K98MC/ME7 4.02 1984303-6.1
K98MC-C/ME-C7 4.02 1984324-0.1
S90MC-C/ME-C8 4.02 1984304-8.1
K90ME9 4.02 1985851-6.0
K90ME-C9 4.02 1987984-5.0
K90MC-C/ME-C6 4.02 1984325-2.1
S80MC-C/ME-C8 4.02 1984308-5.1
K80MC-C/ME-C6 4.02 1984309-7.1
K80ME-C9 4.02 1985480-1.1
S70MC-C/ME-C8/-GI 4.02 1984310-7.2
L70MC-C/ME-C8 4.02 1984311-9.1
S65ME-C8/-GI 4.02 1984915-9.1
S60MC-C/ME-C8/-GI 4.02 1984321-5.2
L60MC-C/ME-C8 4.02 1984313-2.1
S50MC-C/ME-C8 4.02 1984314-4.1
MAN B&W 98-50 ME/ME-C Engine Selection Guide
MAN B&W Contents
Chapter Section
MAN Diesel
4 Electricity Production
Engine preparations for PTO 4.03 1984315-6.2
PTO/BW GCR 4.04 1984316-8.6
Waste Heat Recovery Systems (WHR) 4.05 1985912-8.3
L16/24 GenSet data 4.06 1984205-4.5
L21/31 GenSet data 4.07 1984206-6.5
L23/30H GenSet data 4.08 1984207-8.5
L27/38 GenSet data 4.09 1984209-1.5
L28/32H GenSet data 4.10 1984210-1.5
L32/40 GenSet data 4.11 1984211-3.2

5 Installation Aspects
Space requirements and overhaul heights 5.01 1984375-4.7
Space requirement for
K98ME7 5.02 1987446-6.0
K98ME-C7 5.02 1987443-0.0
S90ME-C8 5.02 1987441-7.0
S80ME-C9 5.02 1987433-4.0
S80ME-C8 5.02 1987439-5.0
K80ME-C9 5.02 1987903-2.0
K80ME-C6 5.02 1987437-1.0
S70ME-C8/-GI 5.02 1987435-8.0
L70ME-C8 5.02 1987432-2.0
S65ME-C8/-GI 5.02 1987808-6.0
S60ME-C/ME-B8/-GI 5.02 1987429-9.0
L60ME-C8 5.02 1987797-6.0
S50ME-C8 5.02 1987362-6.0
Crane beam for overhaul of turbochargers 5.03 1987962-9.0
Crane beam for turbochargers 5.03 1984848-8.2
Engine room crane 5.04 1984830-7.3
Engine outline 5.05 1984731-3.3
Gallery outline 5.06 1984854-7.2
Centre of gravity 5.07 1984832-0.1
Water and oil in engine 5.08 1984831-9.1
Engine pipe connections 5.09 1984833-2.1
Counteranges 5.10 1984834-4.1
Engine seating and holding down bolts 5.11 1984923-1.2
Engine seating prole 5.12 1983916-6.5
Engine top bracing 5.13 1984672-5.8
Mechanical top bracing 5.14 1987939-2.0
Hydraulic top bracing arrangement 5.15 1983921-3.6
Components for Engine Control System 5.16 1984697-7.4
Shaftline earthing device 5.17 1984929-2.4
MAN Diesels Alpha Controllable Pitch (CP) propeller 5.18 1987950-9.0
Hydraulic Power Unit for Alpha CP propeller 5.18 1985320-8.2
Alphatronic 2000 Propulsion Control System 5.18 1985322-1.3

MAN B&W 98-50 ME/ME-C Engine Selection Guide
MAN B&W Contents
Chapter Section
MAN Diesel
6 List of Capacities: Pumps, Coolers & Exhaust Gas
Calculation of capacities 6.01 1987067-9.2
List of capacities and cooling water systems 6.02 1987463-3.0
List of capacities 6.03 1985964-3.1
List of capacities, S70ME-C8 6.03 1987121-8.0
Auxiliary system capacities for derated engines 6.04 1987152-9.0
Pump capacities, pressures and ow velocities 6.04 1983865-0.5
Example 1, Pumps and Cooler Capacity 6.04 1987300-4.0
Freshwater generator 6.04 1987145-8.0
Example 2, Fresh Water Production 6.04 1987301-6.0
Calculation of exhaust gas amount and temperature 6.04 1984318-1.2
Diagram for change of exhaust gas amount 6.04 1984420-9.2
Exhaust gas correction formula 6.04 1987140-9.0
Example 3, Expected Exhaust Gas 6.04 1987302-8.0

7 Fuel
Pressurised fuel oil system 7.01 1984228-2.7
Fuel oil system 7.01 1987660-9.1
Fuel oils 7.02 1983880-4.5
Fuel oil pipes and drain pipes 7.03 1983948-9.4
Fuel oil pipe insulation 7.04 1984051-8.3
Components for fuel oil system 7.05 1983951-2.6
Components for fuel oil system, venting box 7.05 1984735-0.2
Water in fuel emulsication 7.06 1983882-8.4

8 Lubricating Oil
Lubricating and cooling oil system 8.01 1984230-4.3
Hydraulic Power Supply unit 8.02 1984231-6.1
Lubricating oil pipes for turbochargers 8.03 1984232-8.3
Lubricating oil centrifuges and list of lubricating oils 8.04 1983886-5.6
Components for lube oil system 8.05 1983887-7.4
Lubricating oil tank 8.06 1984855-9.1
Crankcase venting and bedplate drain pipes 8.07 1984856-0.1
Hydraulic oil back-ushing 8.08 1984829-7.3
Separate system for hydraulic control unit 8.09 1984852-3.2
Hydraulic control oil system 8.09 1987970-1.0

9 Cylinder Lubrication
Cylinder lubricating oil system 9.01 1984822-4.6
MAN B&W Alpha cylinder lubrication system 9.02 1983889-0.8
Cylinder oil pipe heating 9.02 1987612-0.0
Small heating box with lter, suggestion for 9.02 1987937-9.0

10 Piston Rod Stufng Box Drain Oil
Stufng box drain oil system 10.01 1983974-0.5

MAN B&W 98-50 ME/ME-C Engine Selection Guide
MAN B&W Contents
Chapter Section
MAN Diesel
11 Central Cooling Water System
Central cooling water system 11.01-02 1984696-5.4
Components for central cooling water system 11.03 1983987-2.5

12 Seawater Cooling
Seawater systems 12.01 1983892-4.4
Seawater cooling system 12.02 1983893-6.5
Seawater cooling pipes 12.03 1984930-2.1
Components for seawater cooling system 12.04 1983981-1.3
Jacket cooling water system 12.05 1983894-8.6
Jacket cooling water pipes 12.06 1984931-4.1
Components for jacket cooling water system 12.07 1983896-1.4
Temperature at start of engine 12.08 1983986-0.2

13 Starting and Control Air
Starting and control air systems 13.01 1983898-5.4
Components for starting air system 13.02 1986057-8.1
Starting and control air pipes 13.03 1985903-3.2

14 Scavenge Air
Scavenge air system 14.01 1984860-6.3
Auxiliary blowers 14.02 1984009-0.3
Scavenge air pipes 14.03 1984863-1.1
Electric motor for auxiliary blower 14.04 1984864-3.1
Scavenge air cooler cleaning system 14.05 1987684-9.0
Scavenge air box drain system 14.06 1983913-0.5
Fire extinguishing system for scavenge air space 14.07 1984865-5.4

15 Exhaust Gas
Exhaust gas system 15.01 1983904-6.3
Exhaust gas pipes 15.02 1984070-9.3
Cleaning systems, MAN 15.02 1984071-0.5
Cleaning systems, water and soft blast 15.02 1987916-4.0
Cleaning systems, ABB and Mitsubishi 15.02 1984072-2.3
Exhaust gas system for main engine 15.03 1983905-8.2
Components of the exhaust gas system 15.04 1983907-1.2
Exhaust gas silencer 15.04 1984077-1.1

16 Engine Control System
Engine Control System ME/ME-C 16.01 1984847-6.6
Engine Control System layout 16.01 1987923-5.1
Mechanical-hydraulic system with HPS unit 16.01 1987924-7.0
Engine Control System interface to surrounding systems 16.01 1987925-9.0
Pneumatic manoeuvring diagram 16.01 1987926-0.0

MAN B&W 98-50 ME/ME-C Engine Selection Guide
MAN B&W Contents
Chapter Section
MAN Diesel
17 Vibration Aspects
Vibration aspects 17.01 1984140-5.3
2nd order moments on 4, 5 and 6-cylinder engines 17.02 1988002-6.0
Electrically driven moment compensator for
98-60 ME/ME-C 17.03 1984222-1.5
S50ME-C 17.03 1986878-1.1
Power Related Unbalance (PRU) 17.04 1987990-4.0
Guide force moments 17.05 1984223-3.4
Guide force moments, data 17.05 1984517-0.7
Axial vibrations 17.06 1984224-5.4
Critical running 17.06 1984226-9.3
External forces and moments in layout point for
K98ME7, S80MEC-8 17.07 1988001-4.0
K98ME-C7 17.07 1985738-0.1
S90ME-C8 17.07 1986036-3.1
K90ME9 17.07 1986040-9.1
K90ME-C9 17.07 1986037-5.1
S80ME-C9 17.07 1985475-4.1
K80ME-C9 17.07 1985592-7.2
K80ME-C6 17.07 1983939-4.4
S70ME-C8/-GI 17.07 1986038-7.1
L70ME-C8 17.07 1986039-9.0
S765ME-C8/-GI 17.07 1984904-0.3
S60ME-C8/-GI 17.07 1987023-6.1
L60ME-C8 17.07 1987024-8.0
S50ME-C8 17.07 1987026-1.0

A Appendix
Symbols for piping A 1983866-2.3

MAN B&W Index
MAN Diesel
Subject Section Subject Section
MAN B&W 98-50 ME/ME-C Engine Selection Guide
2nd order moment compensators ........................... 17.02
2nd order moments on 4, 5 and 6-cylinder
engines .............................................................. 17.02

A
ACU, Auxiliary Control Unit ..................................... 16.01
Air cooler cleaning pipes ......................................... 14.05
Air cooler cleaning unit ............................................ 14.05
Air spring, exhaust valve ......................................... 13.03
Alarm system ........................................................... 16.01
Alpha ACC, Alpha Adaptive Cylinder Oil Control ...... 9.02
Alpha ACC, basic and minimum setting with ............ 9.02
Alpha Adaptive Cylinder Oil Control (Alpha ACC) ..... 9.02
Alpha Controllable Pitch (CP) propeller,
MAN Diesels ......................................................... 5.18
Alpha CP propeller, Hydraulic Power Unit for ........... 5.18
Alphatronic 2000 Propulsion Control System .......... 5.18
Arctic running condition ............................................ 3.02
Auto Pump Overboard System ............................... 14.05
Auxiliary blower ......................................................... 1.06
Auxiliary blower control ........................................... 14.02
Auxiliary blower, electric motor for .......................... 14.04
Auxiliary blower, operation panel for ....................... 14.02
Auxiliary blowers .................................................... 14.02
Auxiliary blowers, emergency running ..................... 14.02
Auxiliary Control Unit (ACU) .................................... 16.01
Auxiliary equipment system .................................... 16.01
Auxiliary Propulsion System/Take Home System...... 4.04
Auxiliary system capacities for derated engines ...... 6.04
Axial vibration damper ............................................... 1.06
Axial vibrations ....................................................... 17.06

B
Back-ushing, hydraulic oil ...................................... 8.08
Balancing 1st order moments ................................. 17.02
Balancing other forces and moments ..................... 17.03
Basic and minimum setting with Alpha ACC............. 9.02
Bedplate .................................................................... 1.06
Bedplate drain pipes ................................................. 8.07
Boiler, exhaust gas .................................................. 15.04

C
Cabinet for EICU, Engine Control System
Layout with .............................................................. 16.01
Calculation of capacities .......................................... 6.01
Calculation of exhaust data for derated engine ........ 6.04
Calculation of exhaust gas amount and
temperature ......................................................... 6.04
Capacities of the engine, calculation of .................... 6.04
Capacities, calculation of .......................................... 6.01
CCU, Cylinder Control Unit ..................................... 16.01
C
Central cooler .......................................................... 11.03
Central cooling system, advantages of ................... 11.01
Central cooling system, disadvantages of .............. 11.01
Central cooling water pumps .................................. 11.03
Central cooling water system ........................... 11.01-02
Central cooling water thermostatic valve ................ 11.03
Centre of gravity ....................................................... 5.07
Centrifuges, fuel oil .................................................... 7.05
Cleaning systems, ABB and Mitsubishi ................. 15.02
Cleaning systems, MAN ......................................... 15.02
Cleaning systems, water and soft blast ................. 15.02
Combined turbines .................................................... 4.05
Common Control Cabinet, Engine Control
System Layout with ............................................ 16.01
Compensator solutions, 2nd order moments.......... 17.02
Compensators (2nd order moments),
preparation for .................................................... 17.02
Components for central cooling water system ...... 11.03
Components for Engine Control System .................. 5.16
Components for fuel oil system ............................... 7.05
Components for fuel oil system, venting box ........... 7.05
Components for jacket cooling water system ........ 12.07
Components for lube oil system .............................. 8.05
Components for seawater cooling system ............. 12.04
Components for starting air system ....................... 13.02
Components of the exhaust gas system ................ 15.04
Connecting rod .......................................................... 1.06
Constant ship speed lines ......................................... 2.01
Consumption, cylinder oil .......................................... 1.03
Consumption, lubricating oil ..................................... 1.03
Continuous service rating (S) .................................... 2.04
Control network, for ECS ........................................ 16.01
Cooler heat dissipations ............................................ 6.04
Cooler, central cooling ............................................. 11.03
Cooler, jacket water ...................................... 11.03, 12.04
Cooler, lubricating oil ...................................... 8.05, 11.03
Cooler, scavenge air ..................................... 11.03, 12.04
Cooling water systems, list of capacities and ........... 6.02
Cooling water temperature, recommended .............. 2.08
Counteranges ......................................................... 5.10
Crane beam for overhaul of air cooler ...................... 5.03
Crane beam for overhaul of turbochargers .............. 5.03
Crane beam for turbochargers ................................. 5.03
Crankcase venting and bedplate drain pipes ........... 8.07
Crankshaft ................................................................. 1.06
Critical running ....................................................... 17.06
Cross section, engine ................................................ 1.07
Crosshead ................................................................. 1.06
Cylinder Control Unit (CCU) .................................... 16.01
Cylinder cover ........................................................... 1.06
MAN B&W 98-50 ME/ME-C Engine Selection Guide
MAN B&W Index
Subject Section
MAN Diesel
Subject Section
C
Cylinder frame ........................................................... 1.06
Cylinder liner .............................................................. 1.06
Cylinder lubricating oil pipes ..................................... 9.02
Cylinder lubricating oil system ................................. 9.01
Cylinder lubricating system with dual service tanks . 9.02
Cylinder Lubrication System, MAN B&W Alpha ........ 9.02
Cylinder oil consumption ........................................... 1.03
Cylinder oil feed rate, dosage ................................... 9.01
Cylinder oil pipe heating ........................................... 9.02
Cylinder oils ............................................................... 9.01

D
Damper, axial vibration .............................................. 1.06
Damper, torsional vibration ....................................... 1.06
Data sheet for propeller ............................................. 5.18
Designation of PTO .................................................. 4.01
Diagram for actual project ........................................ 2.05
Diagram for change of exhaust gas amount ............ 6.04
Diagrams of manoeuvring system ........................... 16.01
DMG/CFE Generators ............................................... 4.03
Documentation, symbols for piping ...............................A
Drain from water mist catcher ................................. 14.05
Drain of clean fuel oil from HCU, pumps, pipes ........ 7.01
Drain of contaminated fuel etc. ................................. 7.01
Drain oil system, stufng box .................................. 10.01
Drains, bedplate ........................................................ 8.07

E
Earthing device, shaftline .......................................... 5.17
ECS, Engine Control System ................................... 16.01
ECU, Engine Control Unit ........................................ 16.01
EICU, Engine Interface Control Unit ........................ 16.01
Electric motor for auxiliary blower .......................... 14.04
Electrically driven moment compensator ............... 17.03
Electricity production ............................................... 4.01
Emission control ...................................................... 2.12
Emission limits, IMO NOx .......................................... 2.12
Emulsication, Water In Fuel (WIF) ............................ 7.06
Engine congurations related to SFOC ..................... 6.01
Engine Control System interface to surrounding
systems .............................................................. 16.01
Engine Control System layout ................................ 16.01
Engine Control System ME/ME-C .......................... 16.01
Engine Control System, components for .................. 5.16
Engine Control Unit (ECU) ....................................... 16.01
Engine cross section, referral to PG ......................... 1.07
Engine design and IMO regulation compliance......... 1.01
Engine Interface Control Unit (EICU) ....................... 16.01
Engine layout (heavy propeller) ................................. 2.01
Engine layout and load diagrams ............................. 2.01
E
Engine layout and load diagrams,
ME/ME-C/ME-GI/ME-B engines .......................... 2.04
Engine load diagram ................................................. 2.04
Engine margin ............................................................ 2.01
Engine masses and centre of gravity ........................ 5.05
Engine outline ........................................................... 5.05
Engine pipe connections .................................. 5.05, 5.09
Engine power ............................................................ 1.04
Engine power range and fuel oil consumption ......... 1.04
Engine preparations for PTO .................................... 4.03
Engine room crane ................................................... 5.04
Engine running points, propulsion ............................. 2.01
Engine seating and holding down bolts ................... 5.11
Engine seating prole ............................................... 5.12
Engine space requirements ....................................... 5.01
Engine top bracing ................................................... 5.13
Engine type designation ........................................... 1.02
Example 1, Pumps and Cooler Capacity ................. 6.04
Example 2, Fresh Water Production ......................... 6.04
Example 3, Expected Exhaust Gas ......................... 6.04
Examples of graphic calculation of SFOC ............... 2.08
Exhaust data for derated engine, calculation of ........ 6.04
Exhaust gas amount and temperature ...................... 6.04
Exhaust gas boiler ................................................... 15.04
Exhaust gas by-pass ................................................ 3.02
Exhaust gas compensator after turbocharger ......... 15.04
Exhaust gas correction formula ................................ 6.04
Exhaust gas data at specied MCR (ISO) ................. 6.04
Exhaust gas pipes .................................................. 15.02
Exhaust gas receiver with variable by-pass .............. 3.02
Exhaust gas silencer .............................................. 15.04
Exhaust gas system ....................................... 1.06, 15.01
Exhaust gas system for main engine ..................... 15.03
Exhaust turbocharger ................................................ 1.06
Exhaust valve ............................................................ 1.06
Exhaust valve air spring pipes ................................. 13.03
Expansion tank, jacket water system ...................... 12.07
Extended load diagram for speed derated engines .. 2.04
External forces and moments in layout point
for K80ME-C6 ..................................................... 17.07
for K80ME-C9 ..................................................... 17.07
for K90ME9 ......................................................... 17.07
for K90ME-C9 ..................................................... 17.07
for K98ME7, S80MEC-8 ..................................... 17.07
for K98ME-C7 ..................................................... 17.07
for L60ME-C8 ..................................................... 17.07
for L70ME-C8 ..................................................... 17.07
for S50ME-C8 ..................................................... 17.07
for S60ME-C8/-GI ............................................... 17.07
for S70ME-C8/-GI ............................................... 17.07
MAN B&W Index
MAN Diesel
Subject Section Subject Section
MAN B&W 98-50 ME/ME-C Engine Selection Guide
E
External forces and moments in layout point
for S765ME-C8/-GI ............................................. 17.07
for S80ME-C9 ..................................................... 17.07
for S90ME-C8 ..................................................... 17.07
External unbalanced moments ................................ 17.01
Extreme ambient conditions ...................................... 3.02

F
Filter, fuel oil .............................................................. 7.05
Fire extinguishing system for scavenge air space 14.07
Flow meter, fuel oil .................................................... 7.05
Flow velocities ........................................................... 6.04
Flushing of lube oil system ........................................ 8.05
Flushing of the fuel oil system ................................... 7.05
Fouled hull ................................................................. 2.01
Frame box ................................................................. 1.06
Fresh water treatment ............................................. 12.07
Freshwater generator ..................................... 6.04, 12.07
Freshwater production for derated engine,
calculation of ......................................................... 6.04
Fuel and lubricating oil consumption ........................ 1.03
Fuel considerations ................................................... 7.01
Fuel consumption at an arbitrary load ...................... 2.11
Fuel ow velocity and viscosity ................................. 7.01
Fuel oil centrifuges .................................................... 7.05
Fuel oil circulating pumps ......................................... 7.05
Fuel oil lter ............................................................... 7.05
Fuel oil ow meter ..................................................... 7.05
Fuel oil heater ............................................................ 7.05
Fuel oil pipe heat tracing ........................................... 7.04
Fuel oil pipe insulation .............................................. 7.04
Fuel oil pipes and drain pipes .................................. 7.03
Fuel oil pressure booster ........................................... 1.06
Fuel oil supply pumps ............................................... 7.05
Fuel oil system .......................................................... 7.01
Fuel oil system components ..................................... 7.05
Fuel oil system, ushing of ........................................ 7.05
Fuel oil venting box ................................................... 7.05
Fuel oils .................................................................... 7.02
Fuel valves ................................................................. 1.06

G
Gallery arrangement .................................................. 1.06
Gallery outline ................................................... 5.05, 5.06
Generator step-up gear and exible coupling ........... 4.04
Graphic calculation of SFOC, examples ................... 2.08
Guide force moments ............................................. 17.05
Guide force moments, data .................................... 17.05
Guiding heavy fuel oil specication ........................... 7.02

H
HCU, Hydraulic Cylinder Unit .................................... 1.06
Heat loss in piping ..................................................... 7.04
Heat radiation and air consumption .......................... 6.02
Heat tracing, fuel oil pipe .......................................... 7.04
Heater, fuel oil ............................................................ 7.05
Heating of fuel drain pipes ........................................ 7.01
Heating, cylinder oil pipe ........................................... 9.02
Heavy fuel oil (HFO) ................................................... 7.01
Heavy fuel oil specication, guiding .......................... 7.02
Holding down bolts, engine seating and ................... 5.11
HPS, Hydraulic Power Supply ................................. 16.01
H-type guide force moment .................................... 17.05
Hydraulic control oil system ..................................... 8.09
Hydraulic Cylinder Unit, HCU ................................... 1.06
Hydraulic oil back-ushing ....................................... 8.08
Hydraulic Power Supply ............................................ 1.06
Hydraulic Power Supply (HPS) ................................ 16.01
Hydraulic Power Supply unit .................................... 8.02
Hydraulic Power Supply unit and lubricating
oil pipes ................................................................. 8.02
Hydraulic Power Unit for Alpha CP propeller ........... 5.18
Hydraulic top bracing arrangement .......................... 5.15

I
IMO NOx emission limits ........................................... 2.12
Indicator cock ............................................................ 1.06
Inuence on the optimum propeller speed................ 2.02
Insulation, fuel oil pipe ............................................... 7.04

J
Jacket cooling water pipes .................................... 12.06
Jacket cooling water system .................................. 12.05
Jacket cooling water temperature control ................. 6.04
Jacket water cooler ...................................... 11.03, 12.04
Jacket water cooling pump .......................... 11.03, 12.07
Jacket water preheater ............................................ 12.07
Jacket water system ............................................... 11.03
Jacket water thermostatic valve .............................. 12.07

L
L16/24 GenSet data ................................................. 4.06
L21/31 GenSet data ................................................. 4.07
L23/30H GenSet data ............................................... 4.08
L27/38 GenSet data ................................................. 4.09
L28/32H GenSet data ............................................... 4.10
L32/40 GenSet data ................................................. 4.11
Layout diagram sizes ............................................... 2.03
Limits for continuous operation, operating curves .... 2.04
List of capacities ...................................................... 6.03
List of capacities and cooling water systems .......... 6.02
MAN B&W 98-50 ME/ME-C Engine Selection Guide
MAN B&W Index
Subject Section
MAN Diesel
Subject Section
L
List of capacities, S70ME-C8 ................................... 6.03
Load diagram, examples of the use of ...................... 2.04
Local Operating Panel (LOP) ................................... 16.01
LOP, Local Operating Panel .................................... 16.01
Low load operation, limits ......................................... 2.04
Lube oil system, ushing of ....................................... 8.05
Lubricating and cooling oil system ........................... 8.01
Lubricating of turbochargers ..................................... 8.01
Lubricating oil centrifuges and list of lubricating oils 8.04
Lubricating oil consumption ...................................... 1.03
Lubricating oil cooler ....................................... 8.05,11.03
Lubricating oil data .................................................... 1.04
Lubricating oil full ow lter ....................................... 8.05
Lubricating oil pipes for turbochargers .................... 8.03
Lubricating oil pipes, Hydraulic Power Supply
unit and ................................................................. 8.02
Lubricating oil pump .................................................. 8.05
Lubricating oil tank ................................................... 8.06
Lubricating oil temperature control valve .................. 8.05
Lubricating oils, list of ............................................... 8.04
Lubricator control system ......................................... 9.02

M
Main bearing .............................................................. 1.06
Main Operating Panel (MOP) ................................... 16.01
MAN B&W Alpha Cylinder Lubrication ...................... 1.06
MAN B&W Alpha cylinder lubrication system .......... 9.02
MAN B&W Alpha Cylinder Lubrication,
wiring diagram ...................................................... 9.02
MAN B&W Alpha Cylinder Lubricators on engine ..... 9.02
MAN Diesels Alpha Controllable Pitch (CP)
propeller ............................................................... 5.18
Marine diesel oil ........................................................ 7.01
Mass of water and oil ................................................ 5.08
Matching point (O) ..................................................... 2.04
ME advantages .......................................................... 1.01
ME Engine description ............................................. 1.06
Mechanical top bracing ............................................ 5.14
Mechanical-hydraulic system with HPS unit .......... 16.01
Moment compensators (2nd order),
basic design regarding ....................................... 17.02
Moment compensators (2nd order),
determine the need ............................................. 17.02
MOP, Main Operating Panel .................................... 16.01

N
Nodes and Compensators ...................................... 17.03
NOx reduction ........................................................... 2.12
NOx Reduction by SCR ............................................ 3.03
NOx reduction methods ............................................ 2.12

O
Oil, masses of ............................................................ 5.08
Operating curves and limits for continuous
operation ............................................................... 2.04
Outline, engine .......................................................... 5.05
Overcritical running ................................................. 17.06
Overhaul of engine, space requirements ................... 5.01
Overload operation, limits ......................................... 2.04

P
Performance curves ................................................. 1.05
Pipe connections, engine ................................. 5.05, 5.09
Pipes, air cooler cleaning ........................................ 14.05
Pipes, bedplate drain ................................................ 8.07
Pipes, exhaust gas .................................................. 15.02
Pipes, exhaust valve air spring ................................ 13.03
Pipes, re extinguishing for scavenge air space ..... 14.07
Pipes, jacket water cooling ..................................... 12.06
Pipes, scavenge air ................................................. 14.03
Pipes, seawater cooling .......................................... 12.03
Pipes, starting air ..................................................... 13.03
Pipes, turbocharger lubricating oil ............................ 8.03
Piping arrangements ................................................. 1.06
Piping, symbols for .........................................................A
Piston ........................................................................ 1.06
Piston rod .................................................................. 1.06
Pneumatic manoeuvring diagram .......................... 16.01
Power management system .................................... 16.01
Power Related Unbalance (PRU) ........................... 17.04
Power Take Off (PTO) ................................................ 4.01
Power Take Off/Gear Constant Ratio (PTO/GCR) ..... 4.04
Power Turbine Generator (PTG) ................................ 4.05
Power, Speed, Dimensions ...................................... 1.03
Preheater, jacket water ............................................ 12.07
Preheating of diesel engine ..................................... 12.08
Pressurised fuel oil system ....................................... 7.01
Propeller clearance .................................................... 5.18
Propeller curve .......................................................... 2.01
Propeller design point ............................................... 2.01
Propeller diameter and pitch, inuence on
optimum propeller speed ..................................... 2.02
Propeller, data sheet .................................................. 5.18
Propulsion and engine running points ....................... 2.01
Propulsion control station on the main bridge .......... 5.18
MAN B&W Index
MAN Diesel
Subject Section Subject Section
MAN B&W 98-50 ME/ME-C Engine Selection Guide
P
Propulsion Control System, Alphatronic 2000 .......... 5.18
PTG, Power Turbine Generator ................................. 4.05
PTO, engine preparations for .................................... 4.03
PTO/BW GCR ........................................................... 4.04
PTO/RCF .................................................................. 4.01
Pump capacities, pressures and ow velocities ...... 6.04
Pump, jacket water cooling .......................... 11.03, 12.04
Pump, seawater cooling .......................................... 12.04
Pumps, central cooling ............................................ 11.03
Pumps, fuel oil circulating ......................................... 7.05
Pumps, fuel oil supply ............................................... 7.05
Pumps, jacket water cooling ................................... 12.07
Pumps, lubricating oil ................................................ 8.05
Pumps, seawater cooling ........................................ 11.03

R
Recommendation for operation ................................ 2.04
Reduction station, control and safety air ................ 13.02
Reduction valve, turbocharger cleaning etc ............ 13.02
Remote control system ........................................... 16.01
Renk KAZ clutch for auxilliary propulsion systems ... 5.18
Reversing ................................................................... 1.06

S
Safety system .......................................................... 16.01
Scavenge air box drain system .............................. 14.06
Scavenge air cooler ............................. 1.06, 11.03, 12.04
Scavenge air cooler cleaning system ..................... 14.05
Scavenge air cooler requirements ........................... 14.02
Scavenge air pipes ................................................. 14.03
Scavenge air system ...................................... 1.06, 14.01
Sea margin and heavy weather ................................. 2.01
Seawater cooling pipes .......................................... 12.03
Seawater cooling pump .......................................... 12.04
Seawater cooling pumps ......................................... 11.03
Seawater cooling system ....................................... 12.02
Seawater systems .................................................. 12.01
Seawater thermostatic valve ................................... 12.04
Selective Catalytic Reduction (SCR) ......................... 3.03
Separate system for hydraulic control unit ............... 8.09
Servo oil system for VBS type CP propeller .............. 5.18
SFOC calculations .................................................... 2.09
SFOC calculations, example .................................... 2.10
SFOC for high efciency turbochargers ................... 2.07
SFOC guarantee ........................................................ 2.08
SFOC, engine congurations related to .................... 6.01
SFOC, reference conditions and guarantee ............. 2.08
SFOC, with constant speed ...................................... 2.09
S
SFOC, with xed pitch propeller ............................... 2.09
Shaftline earthing device .......................................... 5.17
Side mounted PTO/RCF, space requirement ............ 4.02
Silencer, exhaust gas .............................................. 15.04
Slow down system .................................................. 16.01
Small heating box with lter, suggestion for ............ 9.02
SMG/CFE Generators ............................................... 4.03
Soft blast cleaning, turbocharger cleaning .............. 15.02
Space requirement
for K80ME-C6 ....................................................... 5.02
for K80ME-C9 ....................................................... 5.02
for K98ME7 ........................................................... 5.02
for K98ME-C7 ....................................................... 5.02
for L60ME-C8 ....................................................... 5.02
for L70ME-C8 ....................................................... 5.02
for S50ME-C8 ....................................................... 5.02
for S60ME-C/ME-B8/-GI ...................................... 5.02
for S65ME-C8/-GI ................................................. 5.02
for S70ME-C8/-GI ................................................. 5.02
for S80ME-C8 ....................................................... 5.02
for S80ME-C9 ....................................................... 5.02
for S90ME-C8 ....................................................... 5.02
Space requirements and overhaul heights ............... 5.01
Space requirements for side mounted PTO/RCF
for K80MC-C/ME-C6 ............................................ 4.02
for K80ME-C9 ....................................................... 4.02
for K90MC-C/ME-C6 ............................................ 4.02
for K90ME9 ........................................................... 4.02
for K90ME-C9 ....................................................... 4.02
for K98MC/ME7 .................................................... 4.02
for K98MC-C/ME-C7 ............................................ 4.02
for L60MC-C/ME-C8 ............................................ 4.02
for L70MC-C/ME-C8 ............................................ 4.02
for S50MC-C/ME-C8 ............................................ 4.02
for S60MC-C/ME-C8/-GI ...................................... 4.02
for S65ME-C8/-GI ................................................. 4.02
S70MC-C/ME-C8/-GI ........................................... 4.02
for S80MC-C/ME-C8 ............................................ 4.02
for S90MC-C/ME-C8 ............................................ 4.02
Spark arrester, exhaust gas ..................................... 15.04
Specic Fuel Oil Consumption (SFOC) ..................... 1.04
Specic fuel oil consumption, ME versus
MC engines .......................................................... 2.06
Specied maximum continuous rating (M) ................ 2.04
Spray shields, fuel oil and lubricating oil pipe .......... 7.04
Start of engine, temperature at ............................... 12.08
Starting air compressors ......................................... 13.02
Starting air receivers ................................................ 13.02
Starting air systems, components for ..................... 13.02
MAN B&W 98-50 ME/ME-C Engine Selection Guide
MAN B&W Index
Subject Section
MAN Diesel
Subject Section
S
Starting air valve ........................................................ 1.06
Starting and control air pipes ................................ 13.03
Starting and control air systems ............................. 13.01
Static converter, frequency........................................ 4.03
Steam Turbine Generator (STG) ................................ 4.05
Step-up gear ............................................................. 1.06
STG, Steam Turbine Generator ................................. 4.05
Stufng box ............................................................... 1.06
Stufng box drain oil system ................................. 10.01
Symbols for piping ........................................................A
System, cylinder lubricating oil ................................. 9.01
System, Engine Control ........................................... 16.01
System, exhaust gas ............................................... 15.01
System, exhaust gas for main engine ......... 15.03, 15.04
System, re extinguishing for scavenge air space .. 14.07
System, fuel oil .......................................................... 7.01
System, jacket cooling water .................................. 12.05
System, jacket water ............................................... 11.03
System, lubricating and cooling oil ........................... 8.01
System, MAN B&W Alpha Cylinder Lubrication ........ 9.02
System, manoeuvring .............................................. 16.01
System, scavenge air .............................................. 14.01
System, scavenge air box drain .............................. 14.06
System, scavenge air cooler cleaning ..................... 14.05
System, seawater .................................................... 12.01
System, seawater cooling ....................................... 12.02
System, stufng box drain oil .................................. 10.01
Systems, control and starting air............................. 13.01
Systems, starting air ................................................ 13.01
Systems, turbocharger cleaning .............................. 15.02

T
Tank, deaerating ...................................................... 12.07
Tank, lubricating oil .................................................... 8.06
Telegraph system .................................................... 16.01
Temperature at start of engine .............................. 12.08
Temperature control valve, lubricating oil .................. 8.05
The ME Tier II Engine ............................................... 1.01
Thermostatic valve, central cooling ......................... 11.03
Thermostatic valve, jacket water ............................. 12.07
Thermostatic valve, seawater .................................. 12.04
Thrust bearing ........................................................... 1.06
Top bracing .............................................................. 17.05
Top bracing, engine .................................................. 5.13
Torsional vibration damper ........................................ 1.06
Torsional vibrations .................................................. 17.06
Tuning wheel .............................................................. 1.06
Tunnel gear with hollow exible coupling .................. 4.04
T
Turbines, combined ................................................... 4.05
Turbocharger arrangement and cleaning ................ 15.01
Turbocharger selection ............................................. 3.01
Turbocharger, exhaust ............................................... 1.06
Turbochargers, lubricating of ..................................... 8.01
Turning gear .................................................... 1.06, 13.02
Turning wheel ............................................................ 1.06

U
Undercritical running ............................................... 17.06

V
VBS type CP propeller and range ............................. 5.18
Venting box, fuel oil ................................................... 7.05
Vibration aspects .................................................... 17.01
Vibration limits valid for single order harmonics...... 17.05

W
Waste Heat Recovery Systems (WHR) ..................... 4.05
Water and oil in engine ............................................. 5.08
Water in fuel emulsication ...................................... 7.06
Water mist catcher, drain from ................................ 14.05
Water washing, turbocharger cleaning .................... 15.02
Water, masses of ....................................................... 5.08
Wiring diagram, MAN B&W Alpha Cylinder
Lubrication ............................................................ 9.02

X
X-type guide force moment ..................................... 17.05
MAN B&W
MAN Diesel
Engine Design

1
MAN B&W 1.01
Page 1 of 3
MAN Diesel
MAN B&W ME/MEC/MEGI-TII engines 198 74 69-4.0
The ever valid requirement of ship operators is
to obtain the lowest total operational costs, and
especially the lowest possible specic fuel oil
consumption at any load, and under the prevailing
operating conditions.
However, lowspeed twostroke main engines of
the MC type, with a chain driven camshaft, have
limited exibility with regard to fuel injection and
exhaust valve activation, which are the two most
important factors in adjusting the engine to match
the prevailing operating conditions.
A system with electronically controlled hydraulic
activation provides the required exibility, and
such systems form the core of the ME Engine
Control System, described later in detail in Chap-
ter 16.
Concept of the ME engine
The ME engine concept consists of a hydraulic-
mechanical system for activation of the fuel injec-
tion and the exhaust valves. The actuators are
electronically controlled by a number of control
units forming the complete Engine Control Sys-
tem.
MAN Diesel has specically developed both the
hardware and the software inhouse, in order to
obtain an integrated solution for the Engine Con-
trol System.
The fuel pressure booster consists of a simple
plunger powered by a hydraulic piston activated
by oil pressure. The oil pressure is controlled by
an electronically controlled proportional valve.
The exhaust valve is opened hydraulically by
means of a twostage exhaust valve actuator
activated by the control oil from an electronically
controlled proportional valve. The exhaust valves
are closed by the air spring.
In the hydraulic system, the normal lube oil is used
as the medium. It is ltered and pressurised by a
Hydraulic Power Supply unit mounted on the en-
gine or placed in the engine room.
The starting valves are opened pneumatically by
electronically controlled On/Off valves, which
make it possible to dispense with the mechani-
cally activated starting air distributor.
By electronic control of the above valves accord-
ing to the measured instantaneous crankshaft po-
sition, the Engine Control System fully controls the
combustion process.
System exibility is obtained by means of different
Engine running modes, which are selected either
automatically, depending on the operating condi-
tions, or manually by the operator to meet specic
goals. The basic running mode is Fuel economy
mode to comply with IMO NOx emission limita-
tion.
Engine design and IMO regulation compli-
ance
The ME-C engine is the shorter, more compact
version of the MC engine. It is well suited wherev-
er a small engine room is requested, for instance
in container vessels.
The ME-GI is a dual fuel engine burning natural
gas, otherwise sharing the same compact design
as the ME-C engine. It is designed for the highly
specialised LNG carrier market.
For MAN B&W ME/ME-C/ME-GI-TII designated
engines, the design and performance parameters
have been upgraded and optimised to comply
with the International Maritime Organisation (IMO)
Tier II emission regulations.
The potential derating and part load SFOC gures
for the Tier II engines have also been updated.
For engines built to comply with IMO Tier I emis-
sion regulations, please refer to the Marine Engine
IMO Tier I Project Guide.
The ME Tier II Engine
MAN B&W 1.01
Page 2 of 3
MAN Diesel
MAN B&W ME/MEC/MEGI-TII engines 198 74 69-4.0
ME Advantages
The advantages of the ME range of engines are
quite comprehensive, as seen below:
Lower SFOC and better performance param-
eters thanks to variable electronically controlled
timing of fuel injection and exhaust valves at any
load
Appropriate fuel injection pressure and rate
shaping at any load
Improved emission characteristics, with smoke-
less operation
Easy change of operating mode during opera-
tion
Simplicity of mechanical system with well -
proven simple fuel injection technology familiar
to any crew
Control system with more precise timing, giving
better engine balance with equalized thermal
load in and between cylinders
System comprising performance, adequate
monitoring and diagnostics of engine for longer
time between overhauls
Lower rpm possible for manoeuvring
Better acceleration, astern and crash stop per-
formance
Integrated Alpha Cylinder Lubricators
Upgradable to software development over the
lifetime of the engine
It is a natural consequence of the above that more
features and operating modes are feasible with
our fully integrated control system and, as such,
will be retrottable and eventually offered to own-
ers of ME engines.
Differences between MC/MC-C and
ME/ME-C engines
The electrohydraulic control mechanisms of the
ME engine replace the following components of
the conventional MC engine:
Chain drive for camshaft
Camshaft with fuel cams, exhaust cams and
indicator cams
Fuel pump actuating gear, including roller
guides and reversing mechanism
Conventional fuel pressure booster and VIT system
Exhaust valve actuating gear and roller guides
Engine driven starting air distributor
Electronic governor with actuator
Regulating shaft
Engine side control console
Mechanical cylinder lubricators.
The Engine Control System of the ME engine
comprises:
Control units
Hydraulic power supply unit
Hydraulic cylinder units, including:
Electronically controlled fuel injection, and
Electronically controlled exhaust valve activa-
tion
Electronically controlled starting air valves
Electronically controlled auxiliary blowers
Integrated electronic governor functions
Tacho system
Electronically controlled Alpha lubricators
MAN B&W 1.01
Page 3 of 3
MAN Diesel
MAN B&W ME/MEC/MEGI-TII engines 198 74 69-4.0
Local Operating Panel (LOP)
MAN Diesel PMI system, type PT/S offline,
cylinder pressure monitoring system.
The system can be further extended by optional
systems, such as:
Condition Monitoring System, CoCoSEDS
online
The main features of the ME engine are described
on the following pages.
MAN B&W MC/MC-C, ME/MEC/MEB/-GI engines 198 38 243.6
MAN B&W 1.02
Page 1 of 1
Engine Type Designation
6 S 70 M E B/C 7 -GI -TII
Engine programme
Diameter of piston in cm
S Super long stroke
L Long stroke
K Short stroke
Stroke/bore ratio
Number of cylinders
Concept
E Electronically controlled
C Camshaft controlled
Fuel injection concept
(blank) Fuel oil only
GI Gas injection
Emission regulation
TII IMO Tier level
Design
C Compact engine
B Exhaust valve controlled
by camshaft
Mark version
MAN B&W 1.03
Page 1 of 3
MAN Diesel
MAN B&W 98-50 ME/ME-C Engine Selection Guide 198 59 14-1.3
A
L min
B
C
H
2

H
3

H
1

Power, Speed, Dimensions
Cyl. L
1
kW
K98
ME7
Stroke:
2,660 mm
6 37,380
7 43,610
8 49,840
9 56,070
10 62,300
11 68,530
12 74,760
14 87,220

K98
ME-C7
Stroke:
2,400 mm
6 36,120
7 42,140
8 48,160
9 54,180
10 60,200
11 66,220
12 72,240
14 84,280
L
min
: m 6 cyl. 7 cyl. 8 cyl. 9 cyl. 10 cyl. 11 cyl. 12 cyl. 14 cyl.
Mark 7 mm 12,865 14,615 16,410 19,135 20,885 22,635 24,385 27,885
Dry mass:
ME7 t 1,067 1,220 1,437 1,581 1,755 1,895 2,058 2,328
ME-C7 t 1,046 1,211 1,393 1,532 1,680 1,912 1,975 2,246
Dimensions: A B C H
1
H
2
H
3
ME7 mm 1,750 4,640 1,700 13,375 13,075 -
ME-C7 mm 1,750 4,370 1,700 12,900 12,575 -
L
min
: 6 cyl. 7 cyl. 8 cyl. 9 cyl. 10 cyl. 11 cyl. 12 cyl.
Mark 9 mm 11,210 12,690 14,170 17,360 19,056 20,536 22,124
Dry mass:
ME9 t 945 1,070 1,200 1,400 1,560 1,685 1,820
ME-C9 t 905 1,025 1,150 1,340 1,490 1,615 1,740
Dimensions: A B C H
1
H
2
H
3
ME9 mm * 4,936 1,750 Data is available on request
ME-C9 mm * 4,760 1,700 Data is available on request
* Cyl. distance 6-8 cyl. 9 cyl. 10 cyl. 11 cyl. 12 cyl.
mm 1,480 1-6:1,480 1-5:1,480 1-6:1,480 1-6:1,480
mm - 7-9:1,588 6-10:1,588 7-11:1,588 7-12:1,588
Cyl. L
1
kW
K90
ME9
Stroke:
2,870 mm
6 34,320
7 40,040
8 45,760
9 51,480
10 57,200
11 62,920
12 68,640
K90
ME-C9
Stroke:
2,600 mm
6 34,380
7 40,110
8 45,840
9 51,570
10 57,300
11 63,030
12 68,760
L
min
: 6 cyl. 7 cyl. 8 cyl. 9 cyl.
Mark 8 mm 12,802 14,404 16,006 17,608
Dry mass:
ME-C8 t 1,010 1,136 1,290 1,450
Dimensions: A B C H
1
H
2
H
3
ME-C8 mm 1,602 5,000 1,800 14,500 13,650 14,100
Cyl. L
1
kW
S90
ME-C8
Stroke:
3,188 mm
6 31,620
7 36,890
8 42,160
9 47,430
* The Minimum SFOC at Part Load is somewhat dependent on the MCR layout
speed, i.e. the low SFOC fgure relates to 78 r/min, the higher to 72 r/min.
kW/cyl.
L1
L2
L3
L4
6,230
5,780
5,000
4,630
MEP
bar
SFOC
g/kWh
MCR
Minimum at
Part Load
19.2 174 170
15.4 168 164
90 97 r/min
kW/cyl.
L1
L2
L3
L4
6,020
5,620
4,830
4,510
MEP
bar
SFOC
g/kWh
MCR
Minimum at
Part Load
19.2 174 170
15.4 168 164
97 104 r/min
kW/cyl.
L1
L2
L3
L4
5,270
4,870
4,750
4,380
MEP
bar
SFOC
g/kWh
MCR
Minimum at
Part Load*
20.0 168 164-165
16.0 165 161-162
72 78 r/min
kW/cyl.
L1
L2
L3
L4
5,730
5,180
4,590
4,150
MEP
bar
SFOC
g/kWh
MCR
Minimum at
Part Load
20.0 174 170
16.0 168 164
94 104 r/min
kW/cyl.
L1
L2
L3
L4
5,720
5,110
4,580
4,090
MEP
bar
SFOC
g/kWh
MCR
Minimum at
Part Load
20.0 174 170
16.0 168 164
84 94 r/min
MAN B&W 1.03
Page 2 of 3
MAN Diesel
MAN B&W 98-50 ME/ME-C Engine Selection Guide 198 59 14-1.3
A
L min
B
C
H
2

H
3

H
1

L
min
: 6 cyl. 7 cyl. 8 cyl. 9 cyl.
Mark 9 mm 10,100 11,434 12,768 14,102
Mark 8 mm 11,431 12,855 14,279 -
Dry mass:
ME-C9 t 800 910 1,020 1,130
ME-C8 t 820 922 1,023 -
Dimensions: A B C H
1
H
2
H
3
ME-C9 mm 1,334 5,280 1,900 15,050 13,925 13,500
ME8 mm 1,424 5,000 1,736 14,325 13,175 12,950
Cyl. L
1
kW
S80
ME-C9
Stroke:
3,450 mm
6 27,060
7 31,570
8 36,080
9 40,590

S80
ME-C8
Stroke:
3,200 mm
6 25,080
7 29,260
8 33,440
L
min
: 6 cyl. 7 cyl. 8 cyl. 9 cyl. 10 cyl. 11 cyl. 12 cyl.
Mark 9 mm 10,100 11,434 12,768 14,102 16,676 18,010 19,344
Mark 6 mm 10,864 12,288 13,712 15,136 17,800 19,224 20,648
Dry mass:
ME-C9 t 705 790 890 985 1,130 1,220 1,315
ME-C6 t 734 780 898 1,001 1,107 1,199 1,292
Cyl. L
1
kW
K80
ME-C9
Stroke:
2,600 mm
6 27,180
7 31,710
8 36,240
9 40,770
10 45,300
11 49,830
12 54,360
K80
ME-C6
Stroke:
2,300 mm
6 21,660
7 25,270
8 28,880
9 32,490
10 36,100
11 39,710
12 43,320
Dimensions: A B C H
1
H
2
H
3
ME-C9 mm 1,334 4,480 1,650 12,400 11,825 11,675
ME-C6 mm 1,424 4,088 1,510 11,625 11,375 11,225
L
min
: 5 cyl. 6 cyl. 7 cyl. 8 cyl.
Mark 8 mm 8,308 9,498 10,688 11,878
Dry mass:
ME-C8 t 451 534 605 681
Dimensions: A B C H
1
H
2
H
3
ME-C8 mm 1,190 4,390 1,520 12,550 11,675 11,475
Cyl. L
1
kW
S70
ME-C8
Stroke:
2,800 mm
5 16,350
6 19,620
7 22,890
8 26,160
* The Minimum SFOC at Part Load is somewhat dependent on the MCR layout
speed, i.e. the low SFOC fgure relates to 78 r/min, the higher to 72 r/min.
kW/cyl.
L1
L2
L3
L4
4,510
4,160
4,060
3,750
MEP
bar
SFOC
g/kWh
MCR
Minimum at
Part Load*
20.0 168 164-165
18.0 165 161-162
72 78 r/min
kW/cyl.
L1
L2
L3
L4
4,180
3,860
3,760
3,470
MEP
bar
SFOC
g/kWh
MCR
Minimum at
Part Load*
20.0 168 164-165
18.0 165 161-162
72 78 r/min
kW/cyl.
L1
L2
L3
L4
3,610
3,090
2,890
2,470
MEP
bar
SFOC
g/kWh
MCR
Minimum at
Part Load
18.0 174 170
14.4 168 164
89 104 r/min
kW/cyl.
L1
L2
L3
L4
3,270
2,770
2,610
2,210
MEP
bar
SFOC
g/kWh
MCR
Minimum at
Part Load
20.0 171 167
16.0 165 161
77 91 r/min
kW/cyl.
L1
L2
L3
L4
MEP
bar
SFOC
g/kWh
MCR
Minimum at
Part Load
20.0 174 170
16.0 168 164
94 104 r/min
4,530
4,090
3,620
3,280
MAN B&W 1.03
Page 3 of 3
MAN Diesel
MAN B&W 98-50 ME/ME-C Engine Selection Guide 198 59 14-1.3
A
L min
B
C
H
2

H
3

H
1

Cyl. L
1
kW
L70
ME-C8
Stroke:
2,360 mm
5 16,350
6 19,620
7 22,890
8 26,160
Dimensions: A B C H
1
H
2
H
3
ME-C8 mm 1,190 3,980 1,262 11,250 10,550 10,575
L
min
: 5 cyl. 6 cyl. 7 cyl. 8 cyl.
Mark 8 mm 7,639 8,829 10,019 11,209
Dry mass:
ME-C8 t 437 506 569 642
Cyl. L
1
kW
S65
ME-C8
Stroke:
2,730 mm
5 14,350
6 17,220
7 20,090
8 22,960
Dimensions: A B C H
1
H
2
H
3
ME-C8 mm 1,084 4,124 1,410 11,950 11,225 11,025
L
min
: 5 cyl. 6 cyl. 7 cyl. 8 cyl.
Mark 8 mm 7,068 8,152 9,236 10,320
Dry mass:
ME-C8 t 382 451 512 575
L
min
: 5 cyl. 6 cyl. 7 cyl. 8 cyl.
Mark 8 mm 7,122 8,142 9,162 10,182
Dry mass:
ME-C8 t 321 366 414 463
Dimensions: A B C H
1
H
2
H
3
ME-C8 mm 1,020 3,770 1,300 10,750 10,000 9,725
Cyl. L
1
kW
S60
ME-C8
Stroke:
2,400 mm
5 11,900
6 14,280
7 16,660
8 19,040
Cyl. L
1
kW
L60
ME-C8
Stroke:
2,022 mm
5 11,700
6 14,040
7 16,380
8 18,720
9 21,060
Dimensions: A B C H
1
H
2
H
3
ME-C8 mm 1,020 3,490 1,134 9,675 9,125 8,925
L
min
: 5 cyl. 6 cyl. 7 cyl. 8 cyl. 9 cyl.
Mark 8 mm 7,122 8,142 9,162 10,182 11,202
Dry mass:
ME-C8 t 286 326 354 426 479
L
min
: 5 cyl. 6 cyl. 7 cyl. 8 cyl. 9 cyl.
Mark 8 mm 5,924 6,774 7,624 8,474 9,324
Dry mass:
ME-C8 t 180 211 241 271 293
Dimensions: A B C H
1
H
2
H
3
ME-C8 mm 850 3,150 1,085 9,000 8,475 8,250
Cyl. L
1
kW
S50
ME-C8
Stroke:
2,000 mm
5 8,300
6 9,960
7 11,620
8 13,280
9 14,940
kW/cyl.
L1
L2
L3
L4
3,270
2,750
2,620
2,200
MEP
bar
SFOC
g/kWh
MCR
Minimum at
Part Load
20.0 172 168
16.0 166 162
91 108 r/min
kW/cyl.
L1
L2
L3
L4
2,870
2,450
2,290
1,960
MEP
bar
SFOC
g/kWh
MCR
Minimum at
Part Load
20.0 171 167
16.0 165 161
81 95 r/min
kW/cyl.
L1
L2
L3
L4
2,380
2,010
1,900
1,610
MEP
bar
SFOC
g/kWh
MCR
Minimum at
Part Load
20.0 171 167
16.0 165 161
89 105 r/min
kW/cyl.
L1
L2
L3
L4
2,340
2,000
1,880
1,600
MEP
bar
SFOC
g/kWh
MCR
Minimum at
Part Load
20.0 172 168
16.0 166 162
105 123 r/min
kW/cyl.
L1
L2
L3
L4
1,660
1,410
1,330
1,130
MEP
bar
SFOC
g/kWh
MCR
Minimum at
Part Load
20.0 172 168
16.0 166 162
108 127 r/min
MAN B&W 1.04
Page 1 of 1
MAN Diesel
MAN B&W ME/ME-B/MEC engines 198 46 343.4
Engine Power Range and Fuel Oil Consumption
Engine Power
Power
Speed
L
3
L
4
L
2
L
1
Specic Fuel Oil Consumption (SFOC)
The gures given in this folder represent the val-
ues obtained when the engine and turbocharger
are matched with a view to obtaining the lowest
possible SFOC values while also fullling the IMO
NOX Tier II emission limitations.
Stricter emission limits can be met on request, us-
ing proven technologies.
The SFOC gures are given in g/kWh with a toler-
ance of 5% and are based on the use of fuel with
a lower caloric value of 42,700 kJ/kg (~10,200
kcal/kg) at ISO conditions:
Ambient air pressure .............................1,000 mbar
Ambient air temperature ................................ 25 C
Cooling water temperature ............................ 25 C
Although the engine will develop the power speci-
ed up to tropical ambient conditions, specic
fuel oil consumption varies with ambient condi-
tions and fuel oil lower caloric value. For calcula-
tion of these changes, see Chapter 2.
Lubricating oil data
The cylinder oil consumption gures stated in the
tables are valid under normal conditions.
During runningin periods and under special con-
ditions, feed rates of up to 1.5 times the stated
values should be used.
The following tables contain data regarding the
power, speed and specic fuel oil consumption of
the engine.
Engine power is specied in kW for each cylinder
number and layout points L
1
, L
2
, L
3
and L
4
:
Discrepancies between kW and metric horsepow-
er (1 BHP = 75 kpm/s = 0.7355 kW) are a conse-
quence of the rounding off of the BHP values.
L
1
designates nominal maximum continuous rating
(nominal MCR), at 100% engine power and 100%
engine speed.
L
2
, L
3
and L
4
designate layout points at the other
three corners of the layout area, chosen for easy
reference.
Fig. 1.04.01: Layout diagram for engine power and speed
Overload corresponds to 110% of the power at
MCR, and may be permitted for a limited period of
one hour every 12 hours.
The engine power gures given in the tables re-
main valid up to tropical conditions at sea level as
stated in IACS M28 (1978), i.e.:
Blower inlet temperature ................................ 45 C
Blower inlet pressure .............................1000 mbar
Seawater temperature .................................... 32 C
Relative humidity ..............................................60%
178 51 489.0
MAN B&W
Page 1 of 1
MAN Diesel
198 53 31-6.2 MAN B&W MC/MC-C, ME/ME-C/MEB/GI engines
Performance Curves
1.05
Updated engine and capacities data is
available from the CEAS program on
www.mandieselturbo.com under Products
Marine Engines & Systems Low Speed
CEAS - Engine Room Dimensioning.
MAN B&W 1.06
Page 1 of 6
MAN Diesel
MAN B&W ME/MEC engines 198 46 139.5
Please note that engines built by our licensees
are in accordance with MAN Diesel drawings and
standards but, in certain cases, some local stand-
ards may be applied; however, all spare parts are
interchangeable with MAN Diesel designed parts.
Some components may differ from MAN Diesels
design because of local production facilities or
the application of local standard components.
In the following, reference is made to the item
numbers specied in the Extent of Delivery (EoD)
forms, both for the Basic delivery extent and for
some Options.
Bedplate and Main Bearing
The bedplate is made with the thrust bearing in
the aft end of the engine. The bedplate consists
of high, welded, longitudinal girders and welded
cross girders with cast steel bearing supports.
For tting to the engine seating in the ship, long,
elastic holdingdown bolts, and hydraulic tighten-
ing tools are used.
The bedplate is made without taper for engines
mounted on epoxy chocks.
The oil pan, which is made of steel plate and is
welded to the bedplate, collects the return oil from
the forced lubricating and cooling oil system. The
oil outlets from the oil pan are normally vertical
and are provided with gratings.
Horizontal outlets at both ends can be arranged
for some cylinder numbers, however this must be
conrmed by the engine builder.
The main bearings consist of thin walled steel
shells lined with bearing metal. The main bearing
bottom shell can be rotated out and in by means
of special tools in combination with hydraulic tools
for lifting the crankshaft. The shells are kept in po-
sition by a bearing cap.
Frame Box
The frame box is of welded design. On the ex-
haust side, it is provided with relief valves for each
cylinder while, on the manoeuvring side, it is pro-
vided with a large hinged door for each cylinder.
The crosshead guides are welded on to the frame
box.
The frame box is bolted to the bedplate. The bed-
plate, frame box and cylinder frame are tightened
together by stay bolts.
Cylinder Frame and Stufng Box
The cylinder frame is cast, with the exception of
the S65MEC which is welded, and is provided
with access covers for cleaning the scavenge air
space, if required, and for inspection of scavenge
ports and piston rings from the manoeuvring side.
Together with the cylinder liner it forms the scav-
enge air space.
The cylinder frame is tted with pipes for the pis-
ton cooling oil inlet. The scavenge air receiver, tur-
bocharger, air cooler box and gallery brackets are
located on the cylinder frame. At the bottom of the
cylinder frame there is a piston rod stufng box,
provided with sealing rings for scavenge air, and
with oil scraper rings which prevent crankcase oil
from coming up into the scavenge air space.
Drains from the scavenge air space and the piston
rod stufng box are located at the bottom of the
cylinder frame.
ME Engine Description
MAN B&W 1.06
Page 2 of 6
MAN Diesel
MAN B&W ME/MEC engines 198 46 139.5
Cylinder Liner
The cylinder liner is made of alloyed cast iron
and is suspended in the cylinder frame with a
lowsituated ange. The top of the cylinder liner
is tted with a cooling jacket. The cylinder liner
has scavenge ports and drilled holes for cylinder
lubrication.
Cylinder liners prepared for installation of tem-
perature sensors is basic execution on engines
type 98 and 90 as well as on K80ME-C9 while an
option on all other engines.
Cylinder Cover
The cylinder cover is of forged steel, made in one
piece, and has bores for cooling water. It has a
central bore for the exhaust valve, and bores for
the fuel valves, a starting valve and an indicator
valve.
The cylinder cover is attached to the cylinder
frame with studs and nuts tightened with hydraulic
jacks.
Crankshaft
The crankshaft is of the semibuilt type, made
from forged or cast steel throws. For engines with
9 cylinders or more, the crankshaft is supplied in
two parts.
At the aft end, the crankshaft is provided with the
collar for the thrust bearing, a ange for tting the
gear wheel for the stepup gear to the hydraulic
power supply unit if tted on the engine, and the
ange for the turning wheel and for the coupling
bolts to an intermediate shaft.
At the front end, the crankshaft is tted with the
collar for the axial vibration damper and a ange
for the tting of a tuning wheel. The ange can
also be used for a Power Take Off, if so desired.
Coupling bolts and nuts for joining the crankshaft
together with the intermediate shaft are not nor-
mally supplied.
Thrust Bearing
The propeller thrust is transferred through the
thrust collar, the segments, and the bedplate, to
the end chocks and engine seating, and thus to
the ships hull.
The thrust bearing is located in the aft end of the
engine. The thrust bearing is of the B&WMichell
type, and consists primarily of a thrust collar on
the crankshaft, a bearing support, and segments
of steel lined with white metal.
Engines type 60 and larger with 9 cylinders or
more will be specied with the 360 degree type
thrust bearing, while the 240 degree type is used
in all other engines. MAN Diesels exible thrust
cam design is used for the thrust collar on a range
of engine types.
The thrust shaft is an integrated part of the crank-
shaft and it is lubricated by the engines lubricat-
ing oil system.
Stepup Gear
In case of engine driven HPS, the hydraulic oil
pumps are mounted on the aft of the engine, and
are driven from the crankshaft via stepup gear.
The stepup gear is lubricated from the main engine
system.
Turning Gear and Turning Wheel
The turning wheel is tted to the thrust shaft, and
it is driven by a pinion on the terminal shaft of the
turning gear, which is mounted on the bedplate.
The turning gear is driven by an electric motor
with builtin gear with brake.
A blocking device prevents the main engine from
starting when the turning gear is engaged. En-
gagement and disengagement of the turning gear
is effected manually by an axial movement of the
pinion.
The control device for the turning gear, consisting
of starter and manual control box, can be ordered
as an option.
MAN B&W 1.06
Page 3 of 6
MAN Diesel
MAN B&W ME/MEC engines 198 46 139.5
Axial Vibration Damper
The engine is tted with an axial vibration damper,
mounted on the fore end of the crankshaft. The
damper consists of a piston and a splittype hous-
ing located forward of the foremost main bearing.

The piston is made as an integrated collar on the
main crank journal, and the housing is xed to
the main bearing support. For functional check of
the vibration damper a mechanical guide is tted,
while an electronic vibration monitor can be sup-
plied as an option.
Tuning Wheel / Torsional Vibration Damper
A tuning wheel or torsional vibration damper may
have to be ordered separately, depending on the
nal torsional vibration calculations.
Connecting Rod
The connecting rod is made of forged or cast
steel and provided with bearing caps for the
crosshead and crankpin bearings.
The crosshead and crankpin bearing caps are se-
cured to the connecting rod with studs and nuts
tightened by means of hydraulic jacks.
The crosshead bearing consists of a set of
thinwalled steel shells, lined with bearing metal.
The crosshead bearing cap is in one piece, with
an angular cutout for the piston rod.
The crankpin bearing is provided with thinwalled
steel shells, lined with bearing metal. Lube oil is
supplied through ducts in the crosshead and con-
necting rod.
Piston
The piston consists of a piston crown and piston
skirt. The piston crown is made of heatresistant
steel. A piston cleaning ring located in the very
top of the cylinder liner scrapes off excessive ash
and carbon formations on the piston topland.
The piston has four ring grooves which are
hardchrome plated on both the upper and lower
surfaces of the grooves. The uppermost piston
ring is of the CPR type (Controlled Pressure Re-
lief), whereas the other three piston rings all have
an oblique cut. The uppermost piston ring is high-
er than the others. All four rings are alu-coated on
the outer surface for running-in.
The piston skirt is made of cast iron with a bronze
band.
Piston Rod
The piston rod is of forged steel and is surface-
hardened on the running surface for the stufng
box. The piston rod is connected to the crosshead
with four bolts. The piston rod has a central bore
which, in conjunction with a cooling oil pipe, forms
the inlet and outlet for cooling oil.
Crosshead
The crosshead is of forged steel and is provided
with cast steel guide shoes with white metal on
the running surface.
The telescopic pipe for oil inlet and the pipe for oil
outlet are mounted on the guide shoes.
Scavenge Air System
The air intake to the turbocharger takes place
directly from the engine room through the turbo-
charger intake silencer. From the turbocharger,
the air is led via the charging air pipe, air cooler
and scavenge air receiver to the scavenge ports
of the cylinder liners, see Chapter 14.
MAN B&W 1.06
Page 4 of 6
MAN Diesel
MAN B&W ME/MEC engines 198 46 139.5
Scavenge Air Cooler
For each turbocharger is tted a scavenge air
cooler of the monoblock type designed for sea-
water cooling, alternatively, a central cooling sys-
tem with freshwater can be chosen. The working
pressure is up to 4.5 bar.
The scavenge air cooler is so designed that the
difference between the scavenge air temperature
and the water inlet temperature at specied MCR
can be kept at about 12 C.
Auxiliary Blower
The engine is provided with electricallydriven
scavenge air blowers. The suction side of the
blowers is connected to the scavenge air space
after the air cooler.
Between the air cooler and the scavenge air re-
ceiver, nonreturn valves are tted which auto-
matically close when the auxiliary blowers supply
the air.
The auxiliary blowers will start operating con-
secutively before the engine is started in order to
ensure sufcient scavenge air pressure to obtain
a safe start.
Further information is given in Chapter 14.
Exhaust Gas System
From the exhaust valves, exhaust gas is led to
the exhaust gas receiver where the uctuating
pressure from the individual cylinders is equal-
ised, and the total volume of gas is led to the
turbocharger(s). After the turbocharger(s), the gas
is led to the external exhaust pipe system.
Compensators are tted between the exhaust
valves and the receiver, and between the receiver
and the turbocharger(s).
The exhaust gas receiver and exhaust pipes are
provided with insulation, covered by galvanised
steel plating.
A protective grating is installed between the ex-
haust gas receiver and the turbocharger.
Exhaust Turbocharger
The engines can be tted with either MAN, ABB or
MHI turbochargers. As an option, MAN TCA and
ABB A100-L turbochargers can be delivered with
variable nozzle technology that reduces the fuel
consumption at part load by controlling the scav-
enge air pressure.
The turbocharger choice selection is described in
Chapter 3, and the exhaust gas system in Chapter
15.
Reversing
Reversing of the engine is performed electronical-
ly and controlled by the Engine Control System,
by changing the timing of the fuel injection, the
exhaust valve activation and the starting valves.
The Hydraulic Power Supply
The hydraulic power supply (HPS) lters and pres-
surises the lube oil for use in the hydraulic system.
Depending on the engine type, the HPS consists
of 2-4 pumps driven either mechanically by the
engine or electrically. The hydraulic pressure is
300 bar.
An electrically driven HPS can be mounted on the
engine, usually aft, or in the engine room.
The engine driven HPS is mounted aft for engines
with chain drive aft (8 cylinders or less), and at the
middle for engines with chain drive located in the
middle (9 cylinders or more).
A combined HPS, mechanically driven with elec-
trically driven start-up/back-up pumps for take-
home power, is available as an option for ME/
ME-C engines type 98-60 while basic execution
for S50ME-C.
MAN B&W 1.06
Page 5 of 6
MAN Diesel
MAN B&W ME/MEC engines 198 46 139.5
Hydraulic Cylinder Unit
The hydraulic cylinder unit (HCU), one per cylin-
der, consists of a base plate on which a distributor
block is mounted. The distributor block is tted
with one or more accumulators to ensure that the
necessary hydraulic oil peak ow is available dur-
ing the fuel injection sequence.
The distributor block serves as a mechanical sup-
port for the hydraulically activated fuel pressure
booster and the hydraulically activated exhaust
valve actuator.
Fuel Oil Pressure Booster
The engine is provided with one hydraulically acti-
vated fuel oil pressure booster for each cylinder.
Fuel injection is activated by a multi-way valve
(FIVA), which is electronically controlled by the
Cylinder Control Unit (CCU) of the Engine Control
System.
Further information is given in Section 7.01.
Fuel Valves and Starting Air Valve
The cylinder cover is equipped with two or three
fuel valves, starting air valve, and indicator cock.
The opening of the fuel valves is controlled by
the high pressure fuel oil created by the fuel oil
pressure booster, and the valves are closed by a
spring.
An automatic vent slide allows circulation of fuel
oil through the valve and high pressure pipes
when the engine is stopped. The vent slide also
prevents the compression chamber from being
lled up with fuel oil in the event that the valve
spindle sticks. Oil from the vent slide and other
drains is led away in a closed system.
The fuel oil highpressure pipes are of the double-
wall type with built-in conical support. The pipes
are insulated but not heated.
The mechanically driven starting air distributor
used on the MC engines has been replaced by
one solenoid valve per cylinder, controlled by the
CCUs of the Engine Control System.
Slow turning before starting is a program incorpo-
rated in the basic Engine Control System.
The starting air system is described in detail in
Section 13.01.
The starting valve is opened by control air and is
closed by a spring. The integrated Engine Control
System controls the starting valve timing.
Exhaust Valve
The exhaust valve consists of the valve housing
and the valve spindle. The valve housing is made
of cast iron and is arranged for water cooling. The
housing is provided with a water cooled bottom
piece of steel with a ame hardened seat of the
W-seat design. The exhaust valve spindle is made
of Nimonic. The housing is provided with a spindle
guide.
The exhaust valve is tightened to the cylinder
cover with studs and nuts. The exhaust valve is
opened hydraulically by the electronic valve acti-
vation system and is closed by means of air pres-
sure.
The operation of the exhaust valve is controlled
by the proportional valve which also activates the
fuel injection.
In operation, the valve spindle slowly rotates, driv-
en by the exhaust gas acting on small vanes xed
to the spindle.
Sealing of the exhaust valve spindle guide is pro-
vided by means of Controlled Oil Level (COL), an
oil bath in the bottom of the air cylinder, above the
sealing ring. This oil bath lubricates the exhaust
valve spindle guide and sealing ring as well.
MAN B&W 1.06
Page 6 of 6
MAN Diesel
MAN B&W ME/MEC engines 198 46 139.5
Indicator Cock
The engine is tted with an indicator cock to
which the PMI pressure transducer can be con-
nected.
MAN B&W Alpha Cylinder Lubrication
The electronically controlled MAN B&W Alpha
cylinder lubrication system is applied to the ME
engines, and controlled by the ME Engine Control
System.
The main advantages of the MAN B&W Alpha cyl-
inder lubrication system, compared with the con-
ventional mechanical lubricator, are:
Improved injection timing
Increased dosage exibility
Constant injection pressure
Improved oil distribution in the cylinder liner
Possibility for prelubrication before starting.
More details about the cylinder lubrication system
can be found in Chapter 9.
Gallery Arrangement
The engine is provided with gallery brackets,
stanchions, railings and platforms (exclusive of
ladders). The brackets are placed at such a height
as to provide the best possible overhauling and
inspection conditions.
Some main pipes of the engine are suspended
from the gallery brackets, and the topmost gallery
platform on the manoeuvring side is provided with
overhauling holes for the pistons.
The engine is prepared for top bracings on the ex-
haust side, or on the manoeuvring side.
Piping Arrangements
The engine is delivered with piping arrangements
for:
Fuel oil
Heating of fuel oil pipes
Lubricating oil, piston cooling oil and
hydraulic oil pipes
Cylinder lubricating oil
Cooling water to scavenge air cooler
Jacket and turbocharger cooling water
Cleaning of turbocharger
Fire extinguishing in scavenge air space
Starting air
Control air
Oil mist detector
Various drain pipes.
All piping arrangements are made of steel piping,
except the control air and steam heating of fuel
pipes, which are made of copper.
The pipes are provided with sockets for local
instruments, alarm and safety equipment and,
furthermore, with a number of sockets for supple-
mentary signal equipment. Chapter 18 deals with
the instrumentation.
MAN B&W
Page of
MAN Diesel
Please see the specifc engine Project Guide
Engine Cross Section
198 58 86-4.0
1.07
MAN B&W
MAN Diesel
Engine Layout and Load
Diagrams, SFOC
2
MAN B&W 2.01
Page 1 of 2
MAN Diesel
198 38 338.4 MAN B&W MC/MCC, ME/MEGI/ME-B engines
Engine Layout and Load Diagrams
Introduction
The effective power P of a diesel engine is pro-
portional to the mean effective pressure p
e
and
engine speed n, i.e. when using c as a constant:
P = c x p
e
x n
so, for constant mep, the power is proportional to
the speed:
P = c x n
1
(for constant mep)
When running with a Fixed Pitch Propeller (FPP),
the power may be expressed according to the
propeller law as:
P = c x n
3
(propeller law)
Thus, for the above examples, the power P may
be expressed as a power function of the speed n
to the power of i, i.e.:
P = c x n
i
Fig. 2.01.01 shows the relationship for the linear
functions, y = ax + b, using linear scales.
The power functions P = c x n
i
will be linear func-
tions when using logarithmic scales:
log (P) = i x log (n) + log (c)
Fig. 2.01.01: Straight lines in linear scales
Fig. 2.01.02: Power function curves in logarithmic scales
Thus, propeller curves will be parallel to lines hav-
ing the inclination i = 3, and lines with constant
mep will be parallel to lines with the inclination i = 1.
Therefore, in the Layout Diagrams and Load Dia-
grams for diesel engines, logarithmic scales are
used, giving simple diagrams with straight lines.
Propulsion and Engine Running Points
Propeller curve
The relation between power and propeller speed
for a xed pitch propeller is as mentioned above
described by means of the propeller law, i.e. the
third power curve:
P = c x n
3
, in which:
P = engine power for propulsion
n = propeller speed
c = constant
Propeller design point
Normally, estimates of the necessary propeller
power and speed are based on theoretical cal-
culations for loaded ship, and often experimental
tank tests, both assuming optimum operating
conditions, i.e. a clean hull and good weather. The
combination of speed and power obtained may
be called the ships propeller design point (PD),
178 05 403.0
178 05 403.1
y
2
1
0
0 1 2
b
a
y=ax+b
x
y=log(P)
i = 0
i = 1
i = 2
i = 3
P = n x c
i
log (P) = i x log (n) + log (c)
x = log (n)
MAN B&W 2.01
Page 2 of 2
MAN Diesel
198 38 338.4 MAN B&W MC/MCC, ME/MEGI/ME-B engines
placed on the light running propeller curve 6. See
below gure. On the other hand, some shipyards,
and/or propeller manufacturers sometimes use a
propeller design point (PD) that incorporates all or
part of the socalled sea margin described below.
the socalled sea margin, which is traditionally
about 15% of the propeller design (PD) power.
Engine layout (heavy propeller)
When determining the necessary engine layout
speed that considers the inuence of a heavy run-
ning propeller for operating at high extra ship resis-
tance, it is (compared to line 6) recommended to
choose a heavier propeller line 2. The propeller
curve for clean hull and calm weather line 6 may
then be said to represent a light running (LR)
propeller.
Compared to the heavy engine layout line 2, we
recommend using a light running of 3.07.0% for
design of the propeller.
Engine margin
Besides the sea margin, a socalled engine mar-
gin of some 10% or 15% is frequently added. The
corresponding point is called the specied MCR
for propulsion (MP), and refers to the fact that the
power for point SP is 10% or 15% lower than for
point MP.
Point MP is identical to the engines specied
MCR point (M) unless a main engine driven shaft
generator is installed. In such a case, the extra
power demand of the shaft generator must also
be considered.
Constant ship speed lines
The constant ship speed lines , are shown at
the very top of the gure. They indicate the power
required at various propeller speeds in order to
keep the same ship speed. It is assumed that, for
each ship speed, the optimum propeller diameter
is used, taking into consideration the total propul-
sion efciency. See denition of in Section 2.02.
Note:
Light/heavy running, fouling and sea margin are
overlapping terms. Light/heavy running of the
propeller refers to hull and propeller deterioration
and heavy weather, whereas sea margin i.e. extra
power to the propeller, refers to the inuence of
the wind and the sea. However, the degree of light
running must be decided upon experience from
the actual trade and hull design of the vessel.
Fig. 2.01.03: Ship propulsion running points and engine
layout
Power, % af L
1
100% = 0,15
= 0,20
= 0,25 = 0,30
L
3
100%
L
4
L
2
Engine margin
(SP=90% of MP)
Sea margin
(15% of PD)
Engine speed, % of L
1
L
1
MP
SP
PD
HR
LR
2 6
PD
Line 2 Propulsion curve, fouled hull and heavy weather
(heavy running), recommended for engine layout
Line 6 Propulsion curve, clean hull and calm weather (light
running), for propeller layout
MP Specied MCR for propulsion
SP Continuous service rating for propulsion
PD Propeller design point
HR Heavy running
LR Light running
Fouled hull
When the ship has sailed for some time, the hull
and propeller become fouled and the hulls re-
sistance will increase. Consequently, the ships
speed will be reduced unless the engine delivers
more power to the propeller, i.e. the propeller will
be further loaded and will be heavy running (HR).
As modern vessels with a relatively high service
speed are prepared with very smooth propeller
and hull surfaces, the gradual fouling after sea
trial will increase the hulls resistance and make
the propeller heavier running.
Sea margin and heavy weather
If, at the same time the weather is bad, with head
winds, the ships resistance may increase com-
pared to operating in calm weather conditions.
When determining the necessary engine power, it
is normal practice to add an extra power margin,
178 05 415.3
MAN B&W 2.02
Page 1 of 2
MAN Diesel
198 38 782.5 MAN B&W MC/MC-C, ME/ME-GI/ME -B engines
D = Optimum propeller diameters
P/D = Pitch/diameter ratio
Shaft power
kW
8.500
8.600
8.700
8.800
8.900
9.000
9.100
9.200
9.300
9.400
9.500
70 80 90 100 110 120 130 r/min
Propeller
speed
P/D
1.00
0.95
0.90
0.85
0.80
D
7.4m
0.75
7.2m
7.0m
6.8m
6.6m
0.70
0.65
0.60
0.55
D
P/D
0.50
Fig. 2.02.01: Inuence of diameter and pitch on propeller design
Propeller diameter and pitch, inuence on the optimum propeller speed
In general, the larger the propeller diameter D,
the lower is the optimum propeller speed and the
kW required for a certain design draught and ship
speed, see curve D in the gure below.
The maximum possible propeller diameter de-
pends on the given design draught of the ship,
and the clearance needed between the propeller
and the aft body hull and the keel.
The example shown in the gure is an 80,000 dwt
crude oil tanker with a design draught of 12.2 m
and a design speed of 14.5 knots.
When the optimum propeller diameter D is in-
creased from 6.6 m to 7.2. m, the power demand
is reduced from about 9,290 kW to 8,820 kW, and
the optimum propeller speed is reduced from 120
r/min to 100 r/min, corresponding to the constant
ship speed coefcient = 0.28 (see denition of
in Section 2.02, page 2).
Once an optimum propeller diameter of maximum
7.2 m has been chosen, the corresponding op-
timum pitch in this point is given for the design
speed of 14.5 knots, i.e. P/D = 0.70.
However, if the optimum propeller speed of 100
r/min does not suit the preferred / selected main
engine speed, a change of pitch away from opti-
mum will only cause a relatively small extra power
demand, keeping the same maximum propeller
diameter:
going from 100 to 110 r/min (P/D = 0.62) requires
8,900 kW i.e. an extra power demand of 80 kW.
going from 100 to 91 r/min (P/D = 0.81) requires
8,900 kW i.e. an extra power demand of 80 kW.
In both cases the extra power demand is only
of 0.9%, and the corresponding equal speed
curves are =+0.1 and =0.1, respectively, so
there is a certain interval of propeller speeds in
which the power penalty is very limited.
178 47 032.0
MAN B&W 2.02
Page 2 of 2
MAN Diesel
198 38 782.5 MAN B&W MC/MC-C, ME/ME-GI/ME -B engines
Constant ship speed lines
The constant ship speed lines , are shown at
the very top of Fig. 2.02.02. These lines indicate
the power required at various propeller speeds to
keep the same ship speed provided that the op-
timum propeller diameter with an optimum pitch
diameter ratio is used at any given speed, taking
into consideration the total propulsion efciency.
Normally, the following relation between neces-
sary power and propeller speed can be assumed:
P
2
= P
1
x (n
2
/n
1
)

where:
P = Propulsion power
n = Propeller speed, and
= the constant ship speed coefcient.
For any combination of power and speed, each
point on lines parallel to the ship speed lines gives
the same ship speed.
When such a constant ship speed line is drawn
into the layout diagram through a specied pro-
pulsion MCR point MP
1
, selected in the layout
area and parallel to one of the lines, another
specied propulsion MCR point MP
2
upon this
line can be chosen to give the ship the same
speed for the new combination of engine power
and speed.
Fig. 2.02.02 shows an example of the required
power speed point MP
1
, through which a constant
ship speed curve = 0.25 is drawn, obtaining
point MP
2
with a lower engine power and a lower
engine speed but achieving the same ship speed.
Provided the optimum pitch/diameter ratio is used
for a given propeller diameter the following data
applies when changing the propeller diameter:
for general cargo, bulk carriers and tankers
= 0.25 0.30
and for reefers and container vessels
= 0.15 0.25
When changing the propeller speed by changing
the pitch diameter ratio, the constant will be dif-
ferent, see above.
Fig. 2.02.02: Layout diagram and constant ship speed lines
178 05 667.0
=0,15
=0,20
=0,25 =0,30
Constant ship speed lines
MP
2
MP
1
=0,25
1
2
3
4
m
e
p
1
0
0
%
9
5
%
9
0
%
8
5
%
8
0
%
7
5
%
7
0
%
Nominal propeller curve
75% 80% 85% 90% 95% 100% 105%
Engine speed
Power
110%
100%
90%
80%
70%
60%
50%
40%
MAN B&W 2.03
Page 1 of 1
MAN Diesel
198 69 11-0.1 MAN B&W MC/MC-C, ME/ME-C/ME-B/-GI-TII engines
L
4
L
2
L
1
L
3
L
4
L
2
L
1
L
3
L
4
L
2
L
1
L
3
L
4
L
2
L
1
L
3
L
4
L
2
L
1
L
3
Power
Speed
Power
Speed
Power
Speed
Power
Speed
Power
Speed
L
4
L
2
L
1
L
3
L
4
L
2
L
1
L
3
L
4
L
2
L
1
L
3
L
4
L
2
L
1
L
3
L
4
L
2
L
1
L
3
Power
Speed
Power
Speed
Power
Speed
Power
Speed
Power
Speed
100 - 80% power and
100 - 85% speed range
valid for the types:
K90MC-C/6
K80MC-C/ME-C6,
L60MC-C/ME-C8, S46MC-C8,
S46ME-B8, S42MC7, S40ME-
B9, S35MC7, S35ME-B9,
L35MC6, S26MC6,
S90MC-C/ME-C8,
S80MC-C8, S80ME-C8/9,
S70MC-C/ME-C8/-GI, S65ME-
C8/-GI, S60MC-C/ME-C8/-GI,
S60ME-B8, S50MC-C/ME-C8,
S50ME-B8/9
100 - 80% power and
100 - 90% speed range
valid for the types:
K90ME/ME-C9,
K80ME-C9
100 - 80% power and
100 - 93% speed range
valid for the types:
K98MC/MC-C7,
K98ME/ME-C7
100 - 90% power and
100 - 91.5% speed range
valid for the types:
S40MC-C9,
S35MC-C9,
Fig. 2.03.01 Layout diagram sizes
Layout Diagram Sizes
178 60 45-2.0
See also Section 2.05 for actual project.
100 - 80% power and
100 - 84% speed range
valid for the types:
L70MC-C/ME-C8,
MAN B&W 2.04
Page 1 of 10
MAN Diesel
198 69 93-5.1 MAN B&W ME/ME-C/ME-B/-GI-TII engines
Engine Layout and Load Diagram
Engine Layout Diagram
An engines layout diagram is limited by two con-
stant mean effective pressure (mep) lines L
1
L
3

and L
2
L
4
, and by two constant engine speed
lines L
1
L
2
and L
3
L
4
. The L
1
point refers to the
engines nominal maximum continuous rating, see
Fig. 2.04.01.
Within the layout area there is full freedom to se-
lect the engines specied SMCR point M which
suits the demand for propeller power and speed
for the ship.
On the horizontal axis the engine speed and on
the vertical axis the engine power are shown on
percentage scales. The scales are logarithmic
which means that, in this diagram, power function
curves like propeller curves (3rd power), constant
mean effective pressure curves (1st power) and
constant ship speed curves (0.15 to 0.30 power)
are straight lines.
Specied maximum continuous rating (M)
Based on the propulsion and engine running
points, as previously found, the layout diagram
of a relevant main engine may be drawnin. The
SMCR point (M) must be inside the limitation lines
of the layout diagram; if it is not, the propeller
speed will have to be changed or another main
engine type must be chosen.
Continuous service rating (S)
The continuous service rating is the power need-
ed in service including the specied sea margin
and heavy/light running factor of the propeller
at which the engine is to operate, and point S
is identical to the service propulsion point (SP)
unless a main engine driven shaft generator is
installed.
178 60 85-8.0
Fig. 2.04.01: Engine layout diagram
L
1
L
2
L
3
L
4
Speed
Power
O=M
S
1
Matching point (O)
For practical reasons we have chosen to use the
designation O for the matching point.
The matching point O is placed on line 1 of the
load diagram, see Fig. 2.04.01, and for technical
reasons the power of O always has to be equal to
the power of M. Point O normally coincides with
point M.
For ME and ME-C/-GI engines, the timing of the
fuel injection and the exhaust valve activation are
electronically optimised over a wide operating
range of the engine. Therefore the selection of
matching point only has a meaning in connection
with the turbocharger matching and the compres-
sion ratio.
For ME-B engines, only the fuel injection (and not
the exhaust valve activation) is electronically con-
trolled over a wide operating range of the engine,
and the compression ratio is nearly constant as
for an MC engine.
The lowest specic fuel oil consumption for the
ME and ME-C/-GI engines is optained at 70%
and for ME-B engines at 80% of the matching
point (O).
MAN B&W 2.04
Page 2 of 10
MAN Diesel
198 69 93-5.1 MAN B&W ME/ME-C/ME-B/-GI-TII engines
Engine shaft power, % of A
40
45
50
55
60
65
70
75
80
85
90
95
100
105
110
7
5
4
1 2 6
7
8 4 1
2
6
5
O=A=M
3
9
Engine speed, % of A
60 65 70 75 80 85 90 95 100 105 110
Denitions
The engines load diagram, see Fig. 2.04.02, de-
nes the power and speed limits for continuous as
well as overload operation of an installed engine
having a matching point O and a specied MCR
point M that conrms the ships specication.
Point A is a 100% speed and power reference
point of the load diagram, and is dened as the
point on the propeller curve (line 1), through the
matching point O, having the specied MCR
power. Normally, point M is equal to point A, but
in special cases, for example if a shaft generator
is installed, point M may be placed to the right of
point A on line 7.
The service points of the installed engine incorpo-
rate the engine power required for ship propulsion
and shaft generator, if installed.
Operating curves and limits for continuous
operation
The continuous service range is limited by four
lines: 4, 5, 7 and 3 (9), see Fig. 2.04.02. The pro-
peller curves, line 1, 2 and 6 in the load diagram
are also described below.

Line 1:
Propeller curve through specied MCR (M) engine
layout curve.
Line 2:
Propeller curve, fouled hull and heavy weather
heavy running.
Line 3 and line 9:
Line 3 represents the maximum acceptable speed
for continuous operation, i.e. 105% of A.
During trial conditions the maximum speed may
be extended to 107% of A, see line 9.
The above limits may in general be extended to
105% and during trial conditions to 107% of the
nominal L
1
speed of the engine, provided the tor-
sional vibration conditions permit.
The overspeed setpoint is 109% of the speed
in A, however, it may be moved to 109% of the
nominal speed in L
1
, provided that torsional vibra-
tion conditions permit.
Running at low load above 100% of the nominal L
1

speed of the engine is, however, to be avoided for
extended periods. Only plants with controllable
pitch propellers can reach this light running area.
Regarding i in the power function P = c x n
i
, see page 2.01.
A 100% reference point
M Specied MCR point
O Matching point
Line 1 Propeller curve through matching point (i = 3)
(engine layout curve)
Line 2 Propeller curve, fouled hull and heavy weather
heavy running (i = 3)
Line 3 Speed limit
Line 4 Torque/speed limit (i = 2)
Line 5 Mean effective pressure limit (i = 1)
Line 6 Propeller curve, clean hull and calm weather
light running (i = 3), for propeller layout
Line 7 Power limit for continuous running (i = 0)
Line 8 Overload limit
Line 9 Speed limit at sea trial
Point M to be located on line 7 (normally in point A)
178 05 427.5
Fig. 2.04.02: Standard engine load diagram
Engine Load Diagram
MAN B&W 2.04
Page 3 of 10
MAN Diesel
198 69 93-5.1 MAN B&W ME/ME-C/ME-B/-GI-TII engines
Recommendation
Continuous operation without limitations is al-
lowed only within the area limited by lines 4, 5,
7 and 3 of the load diagram, except on low load
operation for CP propeller plants mentioned in the
previous section.
The area between lines 4 and 1 is available for
operation in shallow waters, heavy weather and
during acceleration, i.e. for nonsteady operation
without any strict time limitation.
After some time in operation, the ships hull and
propeller will be fouled, resulting in heavier run-
ning of the propeller, i.e. the propeller curve will
move to the left from line 6 towards line 2, and
extra power is required for propulsion in order to
keep the ships speed.
In calm weather conditions, the extent of heavy
running of the propeller will indicate the need for
cleaning the hull and possibly polishing the pro-
peller.
Once the specied MCR (and the matching point)
have been chosen, the capacities of the auxiliary
equipment will be adapted to the specied MCR,
and the turbocharger specication and the com-
pression ratio will be selected.
If the specied MCR (and the matching point) is to
be increased later on, this may involve a change
of the pump and cooler capacities, change of the
fuel valve nozzles, adjusting of the cylinder liner
cooling, as well as rematching of the turbocharger
or even a change to a larger size of turbocharger.
In some cases it can also require larger dimen-
sions of the piping systems.
It is therefore of utmost importance to consider,
already at the project stage, if the specication
should be prepared for a later power increase.
This is to be indicated in the Extent of Delivery.
Line 4:
Represents the limit at which an ample air supply
is available for combustion and imposes a limita-
tion on the maximum combination of torque and
speed.
Line 5:
Represents the maximum mean effective pres-
sure level (mep), which can be accepted for con-
tinuous operation.
Line 6:
Propeller curve, clean hull and calm weather light
running, used for propeller layout/design.
Line 7:
Represents the maximum power for continuous
operation.
Limits for overload operation
The overload service range is limited as follows:
Line 8:
Represents the overload operation limitations.
The area between lines 4, 5, 7 and the heavy
dashed line 8 is available for overload running for
limited periods only (1 hour per 12 hours).
Line 9:
Speed limit at sea trial.
Limits for low load running
As the fuel injection is automatically controlled
over the entire power range, the engine is able to
operate down to around 15% of the nominal L
1

speed.
MAN B&W 2.04
Page 4 of 10
MAN Diesel
198 69 93-5.1 MAN B&W ME/ME-C/ME-B/-GI-TII engines
Extended load diagram for ships operating in extreme heavy running conditions
When a ship with xed pitch propeller is operat-
ing in normal sea service, it will in general be
operating in the hatched area around the design
propeller curve 6, as shown on the standard load
diagram in Fig. 2.04.02.
Sometimes, when operating in heavy weather, the
xed pitch propeller performance will be more
heavy running, i.e. for equal power absorption of
the propeller, the propeller speed will be lower
and the propeller curve will move to the left.
As the low speed main engines are directly cou-
pled to the propeller, the engine has to follow the
propeller performance, i.e. also in heavy running
propeller situations. For this type of operation,
there is normally enough margin in the load area
between line 6 and the normal torque/speed limi-
tation line 4, see Fig. 2.04.02. To the left of line 4
in torquerich operation, the engine will lack air
from the turbocharger to the combustion process,
i.e. the heat load limits may be exceeded and
bearing loads might also become too high.
For some special ships and operating conditions,
it would be an advantage when occasionally
needed to be able to operate the propeller/main
engine as much as possible to the left of line 6,
but inside the torque/speed limit, line 4.
Such cases could be for:
ships sailing in areas with very heavy weather
ships operating in ice
ships with two xed pitch propellers/two main
engines, where one propeller/one engine is de-
clutched for one or the other reason.
The increase of the operating speed range be-
tween line 6 and line 4 of the standard load dia-
gram, see Fig. 2.04.02, may be carried out as
shown for the following engine Example with an
extended load diagram for speed derated engine
with increased light running.
Extended load diagram for speed derated en-
gines with increased light running
The maximum speed limit (line 3) of the engines is
105% of the SMCR (Specied Maximum Continu-
ous Rating) speed, as shown in Fig. 2.04.02.
However, for speed and, thereby, power derated
engines it is possible to extend the maximum
speed limit to 105% of the engines nominal MCR
speed, line 3, but only provided that the torsional
vibration conditions permit this. Thus, the shaft-
ing, with regard to torsional vibrations, has to be
approved by the classication society in question,
based on the extended maximum speed limit.
When choosing an increased light running to be
used for the design of the propeller, the load dia-
gram area may be extended from line 3 to line 3,
as shown in Fig. 2.04.03, and the propeller/main
engine operating curve 6 may have a correspond-
ingly increased heavy running margin before ex-
ceeding the torque/speed limit, line 4.
A corresponding slight reduction of the propel-
ler efciency may be the result, due to the higher
propeller design speed used.
MAN B&W 2.04
Page 5 of 10
MAN Diesel
198 69 93-5.1 MAN B&W ME/ME-C/ME-B/-GI-TII engines
Examples of the use of the Load Diagram
In the following are some examples illustrating the
exibility of the layout and load diagrams.
Example 1 shows how to place the load diagram
for an engine without shaft generator coupled to
a xed pitch propeller.
Example 2 are diagrams for the same congura-
tion, but choosing a matching point on the left
of the heavy running propeller curve (2) provid-
ing an extra engine margin for heavy running
similar to the case in Fig. 2.04.03.
Example 3 shows the same layout for an engine
with xed pitch propeller (example 1), but with a
shaft generator.
Example 4 is a special case of example 3, where
the specied MCR is placed near the top of the
layout diagram.
In this case the shaft generator is cut off,
and the GenSets used when the engine runs
at specied MCR. This makes it possible to
choose a smaller engine with a lower power out-
put.
Example 5 shows diagrams for an engine
coupled to a controllable pitch propeller, with
or without a shaft generator, constant speed or
combinator curve operation.
For a specic project, the layout diagram for actu-
al project shown later in this chapter may be used
for construction of the actual load diagram.
80 100 105 85 55 90 95 60
Engine speed, % A
A 100% reference point
M Specified engine MCR
O Matching point
Engine shaft power, % A
Heavy
running
operation
Normal
operation
50
70
80
90
100
40
110
60
110 115120
L
1
A=O=M
L
2
5%
L
3
L
4
70 75 65
Normal load
diagram area
Extended light
running area
2
1
5 7
6 3 3
4
Line 1: Propeller curve through matching point (O)
layout curve for engine
Line 2: Heavy propeller curve
fouled hull and heavy seas
Line 3: Speed limit
Line 3: Extended speed limit, provided torsional vibration
conditions permit
Line 4: Torque/speed limit
Line 5: Mean effective pressure limit
Line 6: Increased light running propeller curve
clean hull and calm weather
layout curve for propeller
Line 7: Power limit for continuous running
178 60 79-9.0
Fig. 2.04.03: Extended load diagram for speed derated
engine with increased light running
MAN B&W 2.04
Page 6 of 10
MAN Diesel
198 69 93-5.1 MAN B&W ME/ME-C/ME-B/-GI-TII engines
Example 1: Normal running conditions.
Engine coupled to xed pitch propeller (FPP) and without shaft generator
Propulsion and engine
service curve for fouled
hull and heavy weather
Engine speed, % of L
1
100%
Power, % of L
1
100% 7
5
4
1 2 6
1
2
6
7
A=O=M=MP
S=SP
Engine speed, % of L
1
100%
Power, % of L
1
100%
Propulsion and engine
service curve for fouled
hull and heavy weather
7
5
4 1
2
6
3 3
5%L
1
S
A=O=M
3.3%A 5%A
L
1
L
2
L
3
L
4
L
1
L
2
L
3
L
4
M Specied MCR of engine
S Continuous service rating of engine
O Matching point of engine
A Reference point of load diagram
MP Specied MCR for propulsion
SP Continuous service rating of propulsion
Point A of load diagram is found:
Line 1 Propeller curve through matching point (O)
is equal to line 2
Line 7 Constant power line through specied MCR (M)
Point A Intersection between line 1 and 7
178 05 440.8
The specied MCR (M) and the matching point O and its pro-
peller curve 1 will normally be selected on the engine service
curve 2.
Point A is then found at the intersection between propeller
curve 1 (2) and the constant power curve through M, line 7. In
this case point A is equal to point M and point O.
Once point A has been found in the layout diagram, the load
diagram can be drawn, as shown in the gure, and hence the
actual load limitation lines of the diesel engine may be found
by using the inclinations from the construction lines and the
%gures stated.
Layout diagram Load diagram
Fig. 2.04.04: Normal running conditions. Engine coupled to a xed pitch propeller (FPP) and without a shaft generator
MAN B&W 2.04
Page 7 of 10
MAN Diesel
198 69 93-5.1 MAN B&W ME/ME-C/ME-B/-GI-TII engines
Example 2: Special running conditions.
Engine coupled to xed pitch propeller (FPP) and without shaft generator
M Specied MCR of engine
S Continuous service rating of engine
O Matching point of engine
A Reference point of load diagram
MP Specied MCR for propulsion
SP Continuous service rating of propulsion
Point A of load diagram is found:
Line 1 Propeller curve through matching point (O)
placed to the left of line 2
Line 7 Constant power line through specied MCR (M)
Point A Intersection between line 1 and 7
178 05 464.8
In this example, the matching point O has been selected more
to the left than in example 1, providing an extra engine margin
for heavy running operation in heavy weather conditions. In
principle, the light running margin has been increased for this
case.
Propulsion and engine
service curve for fouled
hull and heavy weather
Engine speed, % of L
1 100%
Power, % of L
1
100%
7
5
4
1 2 6
1 2 6
M=MP
7
A=O
S=SP
Propulsion and engine
service curve for fouled
hull and heavy weather
Engine speed, % of L
1 100%
Power, % of L
1
100%
1 2 6 4
5
7
3
S
M
A=O
3.3%A 5%A
5%L
1
3
L
1
L
2
L
3
L
4
L
1
L
2
L
3
L
4
Layout diagram Load diagram
Fig. 2.04.05: Special running conditions. Engine coupled to a xed pitch propeller (FPP) and without a shaft generator
MAN B&W 2.04
Page 8 of 10
MAN Diesel
198 69 93-5.1 MAN B&W ME/ME-C/ME-B/-GI-TII engines
Example 3: Normal running conditions.
Engine coupled to xed pitch propeller (FPP) and with shaft generator
M Specied MCR of engine
S Continuous service rating of engine
O Matching point of engine
A Reference point of load diagram
MP Specied MCR for propulsion
SP Continuous service rating of propulsion
SG Shaft generator power
Point A of load diagram is found:
Line 1 Propeller curve through matching point (O)
Line 7 Constant power line through specied MCR (M)
Point A Intersection between line 1 and 7
178 05 488.8
In example 3 a shaft generator (SG) is installed, and therefore
the service power of the engine also has to incorporate the
extra shaft power required for the shaft generators electrical
power production.
In the gure, the engine service curve shown for heavy run-
ning incorporates this extra power.
The matching point O = A = M will be chosen on this curve, as
shown.
Point A is then found in the same way as in example 1 and the
load diagram can be drawn as shown in the gure.
Engine speed, % of L
1 100%
Power, % of L
1
100%
7
5
4
1 2 6
1 2 6
Propulsion curve for fouled
hull and heavy weather
Engine
service
curve
7
A=O=M
S
SP
SG
SG
MP
Engine speed, % of L
1 100%
Power, % of L
1
100%
Propulsion curve for fouled
hull and heavy weather
Engine service curve for
fouled hull and heavy
weather incl. shaft
generator
4
1 2 6
A=O=M
S
SP
MP
3
5
7
3.3%A 5%A
5%L
1
3
L
1
L
2
L
3
L
4
L
1
L
2
L
3
L
4
Layout diagram Load diagram
Fig. 2.04.06: Normal running conditions. Engine coupled to a xed pitch propeller (FPP) and with a shaft generator
MAN B&W 2.04
Page 9 of 10
MAN Diesel
198 69 93-5.1 MAN B&W ME/ME-C/ME-B/-GI-TII engines
Example 4: Special running conditions.
Engine coupled to xed pitch propeller (FPP) and with shaft generator
M Specied MCR of engine
S Continuous service rating of engine
O Matching point of engine
A Reference point of load diagram
MP Specied MCR for propulsion
SP Continuous service rating of propulsion
SG Shaft generator
Point A and M of the load diagram are found:
Line 1 Propeller curve through point S
Point A Intersection between line 1 and line L
1
L
3
Point M Located on constant power line 7
through point A and with MPs speed
Point O Equal to point A
178 06 351.8
Also for this special case in example 4, a shaft generator is
installed but, compared to example 3, this case has a speci-
ed MCR for propulsion, MP, placed at the top of the layout
diagram.
This involves that the intended specied MCR of the engine
M will be placed outside the top of the layout diagram.
One solution could be to choose a larger diesel engine with
an extra cylinder, but another and cheaper solution is to re-
duce the electrical power production of the shaft generator
when running in the upper propulsion power range.
In choosing the latter solution, the required specied MCR
power can be reduced from point M to point M as shown.
Therefore, when running in the upper propulsion power range,
a diesel generator has to take over all or part of the electrical
power production.
However, such a situation will seldom occur, as ships are
rather infrequently running in the upper propulsion power
range.
Point A, having the highest possible power, is then found at
the intersection of line L
1
L
3
with line 1 and the correspond-
ing load diagram is drawn. Point M is found on line 7 at MPs
speed, and point O=A.
Propulsion curve
for fouled hull
and heavy weather
Power, % of L
1
100%
Engine speed, % of L
1
100%
7
5
4
1 2 6
1 2 6
7
SP
SG
MP
S
A=O
M
M
Propulsion curve
for fouled hull
and heavy weather
Power, % of L
1
100%
Engine speed, % of L
1
100%
1 2 6
7
SP
SG
MP
S
A=O
M
5%L
1
3.3%A 5%A
M
Engine service curve for fouled
hull and heavy weather
incl. shaft generator
4
3
3
L
1
L
2
L
3
L
4
L
1
L
2
L
3
L
4
Layout diagram Load diagram
Fig. 2.04.07: Special running conditions. Engine coupled to a xed pitch propeller (FPP) and with a shaft generator
MAN B&W 2.04
Page 10 of 10
MAN Diesel
198 69 93-5.1 MAN B&W ME/ME-C/ME-B/-GI-TII engines
Example 5: Engine coupled to controllable pitch propeller (CPP) with or without shaft generator
Engine speed
Power
7
5
4
1 2 6
3.3%A 5%A
5%L
1
7
5
1 4
3
S
L
1
L
2
L
3
L
4
Min. speed Max. speed
Combinator curve for
loaded ship and incl.
sea margin
Recommended range for
shaft generator operation
with constant speed
A=O=M
M Specied MCR of engine
O Matching point of engine
A Reference point of load diagram
S Continous service rating of engine
178 39 314.4
Fig. 2.04.08: Engine with Controllable Pitch Propeller
(CPP), with or without a shaft generator
Layout diagram without shaft generator
If a controllable pitch propeller (CPP) is applied,
the combinator curve (of the propeller) will nor-
mally be selected for loaded ship including sea
margin.
The combinator curve may for a given propeller
speed have a given propeller pitch, and this may
be heavy running in heavy weather like for a xed
pitch propeller.
Therefore it is recommended to use a light run-
ning combinator curve (the dotted curve which
includes the sea power margin) as shown in the
gure to obtain an increased operation margin of
the diesel engine in heavy weather to the limit indi-
cated by curves 4 and 5.
Layout diagram with shaft generator
The hatched area shows the recommended speed
range between 100% and 96.7% of the specied
MCR speed for an engine with shaft generator
running at constant speed.
The service point S can be located at any point
within the hatched area.
The procedure shown in examples 3 and 4 for
engines with FPP can also be applied here for en-
gines with CPP running with a combinator curve.
The matching point O
O may, as earlier described, be chosen equal to
point M, see below.
Load diagram
Therefore, when the engines specied MCR point
(M) has been chosen including engine margin,
sea margin and the power for a shaft generator, if
installed, point M may be used as point A of the
load diagram, which can then be drawn.
The position of the combinator curve ensures the
maximum load range within the permitted speed
range for engine operation, and it still leaves a
reasonable margin to the limit indicated by curves
4 and 5.
MAN B&W 2.05
Page 1 of 1
MAN Diesel
198 69 08-7.1 MAN B&W MC/ME Engine Selection Guide-TII
Fig. 2.05.01: Construction of layout diagram
70% 75% 80% 85% 90% 95% 100% 105% 110%
40%
50%
60%
70%
80%
90%
100%
110%
7
5
4
2 6 1
3.3%A 5%A
7
5
A
4
Engine speed, % of L
1
Power, % of L
1
5%L
1
L70MCC/MEC8
K90MCC6, K80MCC/MEC6, L60MCC/MEC8, S46MCC8, S46MEB8, S42MC7, S40MEB9, S35MC7, S35MEB9, L35MC6,
S26MC6, S90MCC/MEC8, S80MCC8, S80MEC8/9, S70MCC/MEC8/GI, S65MEC8/GI, S60MCC/MEC8/GI,
S60MEB8, S50MCC/MEC8, S50MEB8/9
K90ME/MEC9, K80MEC9
S40MCC9, S35MCC9
K98MC/MCC7, K98ME/MEC7
L
1
L
2
L
3
L
4
L
3
L
3
L
4
L
4
L
2
L
3
L
4
L
3
L
4
Diagram for actual project
This gure contains a layout diagram that can
be used for constructing the load diagram for an
actual project, using the %gures stated and the
inclinations of the lines.
178 60 36-8.1
MAN B&W 2.06
Page 1 of 1
MAN Diesel
198 38 36-3.3 MAN B&W ME/ME-C/ME-GI
Specic Fuel Oil Consumption, ME versus MC engines
Fig. 2.06.01: Example of part load SFOC curves for ME and MC with xed pitch propeller
198 97 389.2
As previously mentioned the main feature of the
ME engine is that the fuel injection and the ex-
haust valve timing are optimised automatically
over the entire power range, and with a minimum
speed down to around 15% of the L
1
speed.
Comparing the specic fuel oil comsumption
(SFOC) of the ME and the MC engines, it can be
seen from the gure below that the great advan-
tage of the ME engine is a lower SFOC at part
loads.
It is also noted that the lowest SFOC for the ME
engine is at 70% of O, whereas it was at 80% of O
for the MC engine.

For the ME engine only the turbocharger matching
and the compression ratio (shims under the piston
rod) remain as variables to be determined by the
engine maker / MAN Diesel.
The calculation of the expected specic fuel oil
consumption (SFOC) can be carried out by means
of the following gures for xed pitch propel-
ler and for controllable pitch propeller, constant
speed. Throughout the whole load area the SFOC
of the engine depends on where the matching
point (O) is chosen.
Engine power, % of matching point O
50% 60% 70% 80% 90% 100% 110%
-5
-4
-3
-2
-1
0
+1
+2
+3
ME
MC
SFOC
g/kWh
MAN B&W 2.07
Page 1 of 1
MAN Diesel
198 70 17-7.0 MAN B&W ME/ME-C/ME-GI-TII engines
SFOC for High Efciency Turbochargers
Fig. 2.07.01: Example of part load SFOC curves for high efciency turbochargers
178 60 95-4.0
Engine power, % of matching point O
50% 60% 70% 80% 90% 100%
SFOC
g/kWh
0
+2
2
4
High efficiency turbocharger
Consumption (SFOC) values, see example in
Fig. 2.07.01.
At part load running the lowest SFOC may be
obtained at 70% of the matched power = 70%
of the specied MCR.
All engine types 50 and larger are as standard
tted with high efciency turbochargers, option:
4 59 104.
The high efciency turbocharger is applied to
the engine in the basic design with the view to
obtaining the lowest possible Specic Fuel Oil
MAN B&W 2.08
Page 1 of 2
MAN Diesel
198 70 45-2.1 MAN B&W ME/ME-C/ME-GI/ME-B TII-engines
With
p
max
adjusted
Without
p
max
adjusted
Parameter
Condition
change
SFOC
change
SFOC
change
Scav. air coolant
temperature
per 10 C rise + 0.60% + 0.41%
Blower inlet tem-
perature
per 10 C rise + 0.20% + 0.71%
Blower inlet
pressure
per 10 mbar
rise
0.02% 0.05%
Fuel oil lower
caloric value
rise 1%
(42,700 kJ/kg)
1.00% 1.00%
SFOC reference conditions and guarantee
SFOC guarantee
The SFOC guarantee refers to the above ISO ref-
erence conditions and lower caloric value and is
valid for one running point only. The guaranteed
running point is equal to the powerspeed com-
bination in the matching point (O) = 100% SMCR
but, if requested, a running point between 85%
and 100% SMCR can be selected.
The SFOC guarantee is given with a tolerance
of 5%.
Recommended cooling water temperature
during normal operation
In general, it is recommended to operate the main
engine with the lowest possible cooling water
temperature to the air coolers, as this will reduce
the fuel consumption of the engine, i.e. the engine
performance will be improved.
However, shipyards often specify a constant
(maximum) central cooling water temperature
of 36 C, not only for tropical ambient tempera-
ture conditions, but also for lower ambient tem-
perature conditions. The purpose is probably to
reduce the electric power consumption of the
cooling water pumps and/or to reduce water con-
densation in the air coolers.
Thus, when operating with 36 C cooling water
instead of for example 10 C (to the air coolers),
the specic fuel oil consumption will increase by
approx. 2 g/kWh.
SFOC at reference conditions
The SFOC is given in g/kWh based on
the reference ambient conditions stated in
ISO 3046-1:2002(E) and ISO 15550:2002(E):
1,000 mbar ambient air pressure
25 C ambient air temperature
25 C scavenge air coolant temperature
and is related to a fuel oil with a lower caloric
value of 42,700 kJ/kg (~10,200 kcal/kg).
Any discrepancies between g/kWh and g/BHPh
are due to the rounding of numbers for the latter.
For lower caloric values and for ambient condi-
tions that are different from the ISO reference
conditions, the SFOC will be adjusted according
to the conversion factors in the table below.
With for instance 1 C increase of the scavenge
air coolant temperature, a corresponding 1 C in-
crease of the scavenge air temperature will occur
and involves an SFOC increase of 0.06% if p
max
is
adjusted to the same value.
MAN B&W 2.08
Page 2 of 2
MAN Diesel
MAN B&W ME/ME-C/ME-GI-TII engines 198 70 20-0.0
Examples of Graphic Calculation of SFOC
The following diagrams a, b and c, valid for xed
pitch propeller (b) and constant speed (c), respec-
tively, show the reduction of SFOC in g/kWh, rela-
tive to the SFOC for the nominal MCR L
1
rating.
The solid lines are valid at 100%, 70% and 50% of
matching point (O).
Point O is drawn into the abovementioned Dia-
grams b or c. A straight line along the constant
mep curves (parallel to L
1
L
3
) is drawn through
point O. The intersections of this line and the
curves indicate the reduction in specic fuel oil
consumption at 100, 70 and 50% of the matching
point, related to the SFOC stated for the nominal
MCR L
1
rating.
An example of the calculated SFOC curves are
shown in Diagram a, and is valid for an engine
with xed pitch propeller, see Fig. 2.10.01.
MAN B&W 2.09
Page 1 of 8
MAN Diesel
MAN B&W 98-50 ME/ME-C Engine Selection Guide 198 69 80-3.1
Fig. 2.09.01
SFOC Calculations for K98ME/ME-C7
178 60 93-0.0
Data at nominel MER (L
1
) SFOC at nominal MER (L
1
)
High efciency TC
Engine kW r/min g/kWh
6-12 and 14K98ME7 6.230 97 174
6-12 and 14K98ME-C7 6.020 104 174
Data matching point (O=M):
cyl. No.
Power: 100% of (O) kW
Speed: 100% of (O) r/min
SFOC found: g/kWh
40% 50% 60% 70% 80% 90% 100% 110%
Nominal SFOC
Diagram a
Part Load SFOC curve
% of matching point
SFOC
g/kWh
+4
+3
+2
+1
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
MAN B&W 2.09
Page 2 of 8
MAN Diesel
MAN B&W 98-50 ME/ME-C Engine Selection Guide 198 69 80-3.1
50%
m
atching p
o
int
70%
m
atching p
o
int
10
0%
m
atching p
o
int
1 2 3 4 5
4 5 6 7 8 9 10
0 1 2 3 4 5 6
m
ep
100%
95%
85%
80%
90%
Constant ship speed lines
105%
40%
50%
60%
70%
80%
90%
100%
Power, % of L1
Speed, % of L
1
75% 80% 85% 90% 95% 100%
Nominal propeller curve
=0.15
=0.25
=0.20
=0.30
Diagram b
R
e
d
u
c
tio
n
o
f S
F
O
C
in
g
/k
W
h
re
la
tiv
e
to
th
e
n
o
m
in
a
l in
L1
50%
m
atching p
o
int
70%
m
atching p
o
int
10
0%
m
atching p
o
int
0 1 2 3 4
4 5 6 7 8 9 10
0 1 2 3 4 5 6
m
ep
100%
95%
85%
80%
90%
Constant ship speed lines
105%
40%
50%
60%
70%
80%
90%
100%
Power, % of L1
Speed, % of L
1
75% 80% 85% 90% 95% 100%
Nominal propeller curve
=0.15
=0.25
=0.20
=0.30
Diagram c
R
e
d
u
c
tio
n
o
f S
F
O
C
in
g
/k
W
h
re
la
tiv
e
to
th
e
n
o
m
in
a
l in
L1
Fig. 2.09.02
Fig. 2.09.03
178 60 11-6.0
178 60 12-8.0
SFOC for K98ME/ME-C7 with xed pitch propeller
SFOC for K98ME/ME-C7 with constant speed
MAN B&W 2.09
Page 3 of 8
MAN Diesel
MAN B&W 98-50 ME/ME-C Engine Selection Guide 198 69 80-3.1
Fig. 2.09.01
SFOC Calculations for K90ME-C9, K90ME9 and K80ME-C9
178 60 93-0.0
Data at nominel MER (L
1
) SFOC at nominal MER (L
1
)
High efciency TC
Engine kW r/min g/kWh
6-12K90ME-C9 5.730 104 174
6-12K90ME9 5.720 94 174
6-12K80ME-C9 4.530 104 174
Data matching point (O=M):
cyl. No.
Power: 100% of (O) kW
Speed: 100% of (O) r/min
SFOC found: g/kWh
40% 50% 60% 70% 80% 90% 100% 110%
Nominal SFOC
Diagram a
Part Load SFOC curve
% of matching point
SFOC
g/kWh
+4
+3
+2
+1
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
MAN B&W 2.09
Page 4 of 8
MAN Diesel
MAN B&W 98-50 ME/ME-C Engine Selection Guide 198 69 80-3.1
50%
m
atching p
o
int
70%
m
atching p
o
int
10
0%
m
atching p
o
int
1 2 3 4 5
4 5 6 7 8 9 10
0 1 2 3 4 5 6
m
ep
100%
95%
85%
80%
90%
Constant ship speed lines
105%
40%
50%
60%
70%
80%
90%
100%
Power, % of L1
Speed, % of L
1
75% 80% 85% 90% 95% 100%
Nominal propeller curve
=0.15
=0.25
=0.20
=0.30
Diagram b
R
e
d
u
c
tio
n
o
f S
F
O
C
in
g
/k
W
h
re
la
tiv
e
to
th
e
n
o
m
in
a
l in
L1
50%
m
atching p
o
int
70%
m
atching p
o
int
10
0%
m
atching p
o
int
0 1 2 3 4
4 5 6 7 8 9 10
0 1 2 3 4 5 6
m
ep
100%
95%
85%
80%
90%
Constant ship speed lines
105%
40%
50%
60%
70%
80%
90%
100%
Power, % of L1
Speed, % of L
1
75% 80% 85% 90% 95% 100%
Nominal propeller curve
=0.15
=0.25
=0.20
=0.30
Diagram c
R
e
d
u
c
tio
n
o
f S
F
O
C
in
g
/k
W
h
re
la
tiv
e
to
th
e
n
o
m
in
a
l in
L1
Fig. 2.09.02
Fig. 2.09.03
178 60 09-4.0
178 60 10-4.0
SFOC for K90ME-C9, K90ME9 and K80ME-C9 with xed pitch propeller
SFOC for K90ME-C9, K90ME9 and K80ME-C9 with constant speed
MAN B&W 2.09
Page 5 of 8
MAN Diesel
MAN B&W 98-50 ME/ME-C Engine Selection Guide 198 69 80-3.1
Fig. 2.09.01
SFOC Calculations for S90ME-C8, S80ME-C9/8, K80ME-C6, S70ME-C8, S65ME-C8,
S60ME-C8, L60ME-C8 and S50ME-C8
178 60 93-0.0
Data at nominel MER (L
1
) SFOC at nominal MER (L
1
)
High efciency TC
Engine kW r/min g/kWh
6-9S90ME-C8 5,270 78 168
6-9S80ME-C9 4,510 78 168
6-8S80ME-C8 4,180 78 168
6-12K80ME-C6 3,610 104 174
5-8S70ME-C8 3,270 91 171
5-8S65ME-C8 2,870 95 171
5-8S60ME-C8 2,380 105 171
5-9L60ME-C8 2,340 123 172
5-9S50ME-C8 1,660 127 172
Data matching point (O=M):
cyl. No.
Power: 100% of (O) kW
Speed: 100% of (O) r/min
SFOC found: g/kWh
40% 50% 60% 70% 80% 90% 100% 110%
Nominal SFOC
Diagram a
Part Load SFOC curve
% of matching point
SFOC
g/kWh
+4
+3
+2
+1
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
MAN B&W 2.09
Page 6 of 8
MAN Diesel
MAN B&W 98-50 ME/ME-C Engine Selection Guide 198 69 80-3.1
50%
m
atching p
o
int
70%
m
atching p
o
int
10
0%
m
atching p
o
int
1 2 3 4 5
4 5 6 7 8 9 10
0 1 2 3 4 5 6
m
ep
100%
95%
85%
80%
90%
Constant ship speed lines
105%
40%
50%
60%
70%
80%
90%
100%
Power, % of L1
Speed, % of L
1
75% 80% 85% 90% 95% 100%
Nominal propeller curve
=0.15
=0.25
=0.20
=0.30
Diagram b
R
e
d
u
c
tio
n
o
f S
F
O
C
in
g
/k
W
h
re
la
tiv
e
to
th
e
n
o
m
in
a
l in
L1
50%
m
atching p
o
int
70%
m
atching p
o
int
10
0%
m
atching p
o
int
0 1 2 3 4
4 5 6 7 8 9 10
0 1 2 3 4 5 6
m
ep
100%
95%
85%
80%
90%
Constant ship speed lines
105%
40%
50%
60%
70%
80%
90%
100%
Power, % of L1
Speed, % of L
1
75% 80% 85% 90% 95% 100%
Nominal propeller curve
=0.15
=0.25
=0.20
=0.30
Diagram c
R
e
d
u
c
tio
n
o
f S
F
O
C
in
g
/k
W
h
re
la
tiv
e
to
th
e
n
o
m
in
a
l in
L1
Fig. 2.09.02
Fig. 2.09.03
178 60 07-0.0
178 60 08-2.0
SFOC for S90ME-C8, S80ME-C9/8, K80ME-C6, S70ME-C8, S65ME-C8, S60ME-C8,
L60ME-C8 and S50ME-C8 with xed pitch propeller
SFOC for S90ME-C8, S80ME-C9/8, K80ME-C6, S70ME-C8, S65ME-C8, S60ME-C8,
L60ME-C8 and S50ME-C8 with constant speed
MAN B&W 2.09
Page 7 of 8
MAN Diesel
MAN B&W 98-50 ME/ME-C Engine Selection Guide 198 69 80-3.1
Fig. 2.09.01
SFOC Calculations for L70ME-C8
178 60 93-0.0
Data at nominel MER (L
1
) SFOC at nominal MER (L
1
)
High efciency TC
Engine kW r/min g/kWh
5-8L70ME-C8 3,270 108 172
Data matching point (O=M):
cyl. No.
Power: 100% of (O) kW
Speed: 100% of (O) r/min
SFOC found: g/kWh
40% 50% 60% 70% 80% 90% 100% 110%
Nominal SFOC
Diagram a
Part Load SFOC curve
% of matching point
SFOC
g/kWh
+4
+3
+2
+1
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
MAN B&W 2.09
Page 8 of 8
MAN Diesel
MAN B&W 98-50 ME/ME-C Engine Selection Guide 198 69 80-3.1
50%
m
atching p
o
int
70%
m
atching p
o
int
10
0%
m
atching p
o
int
1 2 3 4 5
4 5 6 7 8 9 10
0 1 2 3 4 5 6
m
ep
100%
95%
85%
80%
90%
Constant ship speed lines
105%
40%
50%
60%
70%
80%
90%
100%
Power, % of L1
Speed, % of L
1
75% 80% 85% 90% 95% 100%
Nominal propeller curve
=0.15
=0.25
=0.20
=0.30
Diagram b
R
e
d
u
c
tio
n
o
f S
F
O
C
in
g
/k
W
h
re
la
tiv
e
to
th
e
n
o
m
in
a
l in
L1
50%
m
atching p
o
int
70%
m
atching p
o
int
10
0%
m
atching p
o
int
0 1 2 3 4
4 5 6 7 8 9 10
0 1 2 3 4 5 6
m
ep
100%
95%
85%
80%
90%
Constant ship speed lines
105%
40%
50%
60%
70%
80%
90%
100%
Power, % of L1
Speed, % of L
1
75% 80% 85% 90% 95% 100%
Nominal propeller curve
=0.15
=0.25
=0.20
=0.30
Diagram c
R
e
d
u
c
tio
n
o
f S
F
O
C
in
g
/k
W
h
re
la
tiv
e
to
th
e
n
o
m
in
a
l in
L1
Fig. 2.09.02
Fig. 2.09.03
178 60 03-3.0
178 60 04-5.0
SFOC for L70ME-C8 with xed pitch propeller
SFOC for L70ME-C8 with constant speed
MAN B&W 2.10
Page of 2
MAN Diesel
MAN B&W K90ME-C9-TII 198 69 67-3.0

Data at nominel MCR (L
1
): 6K90ME-C9
Power 00% 34,380 kW
Speed 00% 04 r/min
Nominal SFOC:
High effciency turbocharger 74 g/kWh
Example of specifed MCR = M
Power 29,223 kW (85% L

)
Speed 00.9 r/min (97% L

)
Turbocharger type High effciency
SFOC found in O=M 70.3 g/kWh
The matching point O used in the above example for
the SFOC calculations:
O

= 00% M = 85% L

power and 97% L

speed
SFOC calculations, example
MAN B&W 2.10
Page 2 of 2
MAN Diesel
MAN B&W K90ME-C9-TII 198 69 67-3.0
Fig. 2.10.01: Example of SFOC for derated 6K90ME-C9 with fxed pitch propeller and high effciency turbocharger
40% 50% 60% 70% 80% 90% 100% 110%
Nominal SFOC

Part Load SFOC curve
30%
% of specified MCR
SFOC
g/kWh
+1
+2
+3
+4
+5
+6
0
-1
-2
-3
-4
-5
-6
-7
-8
-9
-10
-11
g/kWh
SFOC
175
165
174
170
The reductions, see diagram b, in g/kWh compared to
SFOC in L

:
Power in Part load points
SFOC
g/kWh
SFOC
g/kWh
00% O 00% M -3.7 70.3
70% O 2 70% M -7.7 66.3
50% O 3 50% M -3.5 70.5
50%
m
atching p
o
int
70%
m
atching p
o
int
10
0%
m
atching p
o
int
-1 -2 -3 -4 -5
-4 -5 -6 -7 -8 -9 -10
0 -1 -2 -3 -4 -5 -6
m
ep
100%
95%
85%
80%
90%
Constant ship speed lines
105%
40%
50%
60%
70%
80%
90%
100%
Power, % of L1
Speed, % of L
1
75% 80% 85% 90% 95% 100%
Nominal propeller curve
=0.15
=0.25
=0.20
=0.30
Diagram b
R
e
d
u
c
tio
n
o
f S
F
O
C
in
g
/k
W
h
re
|a
tiv
e
to
th
e
n
o
m
in
a
| in
L1

178 60 76-3.0
178 60 87-1.0
MAN B&W 2.11
Page 1 of 1
MAN Diesel
MAN B&W ME/ME-C/ME-GI/ME-B engines 198 38 43-4.4
Once the matching point (O) of the engine has
been chosen, the specic fuel oil consumption at
an arbitrary point S
1
, S
2
or S
3
can be estimated
based on the SFOC at point 1 and 2.
These SFOC values can be calculated by using
the graphs for the relevant engine type for the
propeller curve I and for the constant speed curve
II, giving the SFOC at points 1 and 2, respectively.
Next the SFOC for point S
1
can be calculated as
an interpolation between the SFOC in points 1
and 2, and for point S
3
as an extrapolation.
The SFOC curve through points S
2
, on the left
of point 1, is symmetrical about point 1, i.e. at
speeds lower than that of point 1, the SFOC will
also increase.
The abovementioned method provides only an
approximate value. A more precise indication of
the expected SFOC at any load can be calculated
by using our computer program. This is a service
which is available to our customers on request.
Power, % of A (M)
110%
100%
90%
80%
70%
80% 90% 100% 110%
Speed, % of A
A=M
5
7
2
1
S
2
S
1
S
3
4 3
I II
Fig. 2.11.01: SFOC at an arbitrary load
198 95 962.2
Fuel Consumption at an Arbitrary Load
MAN B&W 2.12
Page 1 of 1
MAN Diesel
MAN B&W ME/MEC/ME-B/GI-TII engines 198 75 40-0.2
Emission Control
IMO NO
x
emission limits
All ME, ME-B and ME-C/-GI engines are, as
standard, delivered in compliance with the IMO
speed dependent NOx limit, measured accord-
ing to ISO 8178 Test Cycles E2/E3 for Heavy Duty
Diesel Engines. These are referred to in the Extent
of Delivery as EoD: 4 06 060 Economy mode with
the options: 4 06 060a Engine test cycle E3 or 4
06 060b Engine test cycle E2.
NO
x
reduction methods
The NO
x
content in the exhaust gas can be re-
duced with primary and/or secondary reduction
methods.
The primary methods affect the combustion pro-
cess directly by reducing the maximum combus-
tion temperature, whereas the secondary me-
thods are means of reducing the emission level
without changing the engine performance, using
external equipment.
030% NO
x
reduction
The ME engines can be delivered with several
operation modes, options: 4 06 063 Port load, 4
06 064 Special emission, 4 06 065 Other emission
limit, and 4 06 066 Dual fuel.
These operation modes may include a Low NOx
mode for operation in, for instance, areas with re-
striction in NOx emission.
For further information on engine operation
modes, see Extent of Delivery.
3050% NO
x
reduction
Water emulsication of the heavy fuel oil is a well
proven primary method. The type of homogeni-
zer is either ultrasonic or mechanical, using water
from the freshwater generator and the water mist
catcher.
The pressure of the homogenised fuel has to be
increased to prevent the formation of steam and
cavitation. It may be necessary to modify some of
the engine components such as the fuel oil pres-
sure booster, fuel injection valves and the engine
control system.
Up to 9598% NO
x
reduction
This reduction can be achieved by means of
secondary methods, such as the SCR (Selec-
tive Catalytic Reduction), which involves an
aftertreatment of the exhaust gas, see Section
3.02.
Plants designed according to this method have
been in service since 1990 on ve vessels, using
Haldor Topse catalysts and ammonia as the re-
ducing agent, urea can also be used.
The SCR unit can be located separately in the
engine room or horizontally on top of the engine.
The compact SCR reactor is mounted before
the turbocharger(s) in order to have the optimum
working temperature for the catalyst. However at-
tention have to be given to the type of HFO to be
used.
For further information about emission control,
please refer to our publication:
Exhaust Gas Emission Control Today and Tomorrow
The publications are available at
www.mandieselturbo.com under Products
Marine Engines & Systems Low Speed
Technical Papers.
MAN B&W
MAN Diesel
Turbocharger Selection &
Exhaust Gas By-pass
3
MAN B&W 3.01
Page 1 of 1
MAN Diesel
198 76 18-1.1 MAN B&W MC/MC-C/ME/ME-C/ME-C-GI/ME-B-TII engines
Updated turbocharger data based on the latest
information from the turbocharger makers are
available from the Turbocharger Selection pro-
gram on www.mandieselturbo.com under Prod-
ucts Marine Engines & Systems Low
Speed Turbocharger Selection.
The MAN B&W engines are designed for the ap-
plication of either MAN, ABB or Mitsubishi (MHI)
turbochargers.
The turbocharger choice is made with a view to
obtaining the lowest possible Specic Fuel Oil
Consumption (SFOC) values at the nominal MCR
by applying the best possible turbochargers.
The engines are, as standard, equipped with as
few turbochargers as possible, please refer to the
below mentioned Turbocharger Selection pro-
gramme.
In most cases one more turbocharger can be ap-
plied, than the number stated, if this is desirable
due to space requirements, or for other reasons.
Additional costs are to be expected.
However, we recommend the Turbocharger se-
lection programme on the Internet, which can be
used to identify a list of applicable turbochargers
for a specic engine layout.
For information about turbocharger arrangement
and cleaning systems, see Section 15.01.
Table 3.01.01: Turbocharger optional designs, MAN
B&W engines
Engines
Conventional
turbocharger
High efciency
turbocharger
Bore 50 Standard design
Bore 46 Standard design
Turbocharger Selection
MAN B&W
Page of
MAN Diesel
This section is not applicable
Exhaust Gas By-pass
3.02
198 58 95-9.0
MAN B&W 3.03
Page 1 of 2
MAN Diesel
198 58 94-7.2 MAN B&W MC/MC-C, ME/ME-C/ME-GI/ME-B Engines
The NOx in the exhaust gas can be reduced with
primary or secondary reduction methods. Primary
methods affect the engine combustion process
directly, whereas secondary methods reduce the
emission level without changing the engine per-
formance using equipment that does not form
part of the engine itself.
For further information about emission control we
refer to our publication:
Exhaust Gas Emission Control Today and Tomorrow
The publication is available at www.mandiesel-
turbo.com under Products Marine Engines &
Systems Low Speed Technical Papers.
Engine with Selective Catalytic Reduction System
Option: 4 60 135
If a reduction between 50 and 98% of NO
x
is re-
quired, the Selective Catalytic Reduction (SCR)
system has to be applied by adding ammonia or
urea to the exhaust gas before it enters a catalytic
converter.
The exhaust gas must be mixed with ammonia be-
fore passing through the catalyst, and in order to
encourage the chemical reaction the temperature
level has to be between 300 and 400 C. During
this process the NO
x
is reduced to N
2
and water.
This means that the SCR unit has to be located
before the turbocharger on twostroke engines
because of their high thermal efciency and there-
by a relatively low exhaust gas temperature.
The amount of ammonia injected into the ex-
haust gas is controlled by a process computer
and is based on the NO
x
production at different
loads measured during the testbed running. Fig.
3.03.01.
As the ammonia is a combustible gas, it is sup-
plied through a doublewalled pipe system, with
appropriate venting and tted with an ammonia
leak detector (Fig. 3.03.01) which shows a simpli-
ed system layout of the SCR installation.

NOx Reduction by SCR
MAN B&W 3.03
Page 2 of 2
MAN Diesel
198 58 94-7.2 MAN B&W MC/MC-C, ME/ME-C/ME-GI/ME-B Engines
Air
Process
computer
Evaporator
Ammonia
tank
Air outlet
Air intake
SCR reactor
Exhaust gas outlet
Deck
Support
Air
Orifice
Engine
NO and O analysers
x 2
High efficiency turbocharger
Preheating and sealing oil
Static mixer
198 99 271.0
Fig. 3.03.01: Layout of SCR system
MAN B&W
MAN Diesel
Electricity Production

4
MAN B&W 4.01
Page 1 of 6
MAN Diesel
198 59 11-6.1 MAN B&W MC/ME Engine Selection Guide
Electricity Production
PTO/GCR (Engines <70)
(Power Take Off/Gear Constant Ratio):
Generator coupled to a constant ratio stepup
gear, used only for engines running at constant
speed.
The DMG/CFE (Direct Mounted Generator/Con-
stant Frequency Electrical) and the SMG/CFE
(Shaft Mounted Generator/Constant Frequency
Electrical) are special designs within the PTO/CFE
group in which the generator is coupled directly to
the main engine crankshaft and the intermediate
shaft, respectively, without a gear. The electrical
output of the generator is controlled by electrical
frequency control.
Within each PTO system, several designs are
available, depending on the positioning of the
gear:
BW I: (Engines >46)
Gear with a vertical generator mounted onto the
fore end of the diesel engine, without any con-
nections to the ship structure.
BW II:
A freestanding gear mounted on the tank top
and connected to the fore end of the diesel en-
gine, with a vertical or horizontal generator.
BW III: (Engines >46)
A crankshaft gear mounted onto the fore end
of the diesel engine, with a sidemounted
generator without any connections to the ship
structure.
BW IV:
A freestanding stepup gear connected to the
intermediate shaft, with a horizontal generator.
The most popular of the gear based alternatives
are the BW III/RCF types for plants with a xed
pitch propeller (FPP) and the BW IV/GCR for
plants with a controllable pitch propeller (CPP).
The BW III/RCF requires no separate seating in
the ship and only little attention from the shipyard
with respect to alignment.
Introduction

Next to power for propulsion, electricity produc-
tion is the largest fuel consumer on board. The
electricity is produced by using one or more of the
following types of machinery, either running alone
or in parallel:
Auxiliary diesel generating sets
Main engine driven generators
Exhaust gas- or steam driven turbo generator
utilising exhaust gas waste heat (Thermo Ef-
ciency System)
Emergency diesel generating sets.
The machinery installed should be selected on the
basis of an economic evaluation of rst cost, ope-
rating costs, and the demand for manhours for
maintenance.
In the following, technical information is given re-
garding main engine driven generators (PTO) and
the auxiliary diesel generating sets produced by
MAN Diesel.
The possibility of using a turbogenerator driven by
the steam produced by an exhaust gas boiler can
be evaluated based on the exhaust gas data.
Power Take Off (PTO)
With a generator coupled to a Power Take Off
(PTO) from the main engine, electrical power
can be produced based on the main engines
low SFOC and the use of heavy fuel oil. Several
standardised PTO systems are available, see Fig.
4.01.01 and the designations in Fig. 4.01.02:
PTO/RCF
(Power Take Off/Renk Constant Frequency):
Generator giving constant frequency, based on
mechanicalhydraulical speed control.
PTO/CFE
(Power Take Off/Constant Frequency Electrical):
Generator giving constant frequency, based on
electrical frequency control.
MAN B&W 4.01
Page 2 of 6
MAN Diesel
198 59 11-6.1 MAN B&W MC/ME Engine Selection Guide
Total
Alternative types and layouts of shaft generators Design Seating efficiency (%)
1a 1b BW I/RCF On engine 8891
(vertical generator)
2a 2b BW II/RCF On tank top 8891
3a 3b BW III/RCF On engine 8891
4a 4b BW IV/RCF On tank top 8891
5a 5b DMG/CFE On engine 8488
6a 6b SMG/CFE On tank top 8488
7 BW I/GCR On engine 92
(vertical generator)
8 BW II/GCR On tank top 92
9 BW III/GCR On engine 92
10 BW IV/GCR On tank top 92
P
T
O
/
R
C
F
P
T
O
/
C
F
E
P
T
O
/
G
C
R
Fig. 4.01.01: Types of PTO
178 19 663.1
MAN B&W 4.01
Page 3 of 6
MAN Diesel
198 42 867.5 MAN B&W K98ME/ME-C, S90ME-C, K90ME/ME-C,
S80ME-C, K80ME-C
Power take off:
BW III S90MEC8/RCF 70060
50: 50 Hz
60: 60 Hz
kW on generator terminals
RCF: Renk constant frequency unit
CFE: Electrically frequency controlled unit
Mark version
Engine type on which it is applied
Layout of PTO: See Fig. 4.01.01
Make: MAN Diesel
178 06 490.0
Fig. 4.01.02: Example of designation of PTO
178 39 556.0
For further information, please refer to our publi-
cation titled:
Shaft Generators for MC and ME engines
The publication is available at www.mandiesel-
turbo.com under Products Marine Engines &
Systems Low Speed Technical Papers.
Designation of PTO
MAN B&W 4.01
Page 4 of 6
MAN Diesel
198 43 000.2 MAN B&W K98MC/MC-C/ME/ME-C, S90MC-C/ME-C,
K90MC-C/ME/ME-C, S80MC/MC-C/ME-C, K80MC-C/ME-C,
S70MC/MCC/ME-C/ME-GI, L70MCC/ME-C, S65ME-C/ME-GI,
S60MC/MC-C/ME-C/ME-GI/ME-B, L60MC-C/ME-C,
S50MC/MC-C/ME-C/ME-B
PTO/RCF
Side mounted generator, BWIII/RCF
(Fig. 4.01.01, Alternative 3)
The PTO/RCF generator systems have been de-
veloped in close cooperation with the German
gear manufacturer RENK. A complete package
solution is offered, comprising a exible coupling,
a stepup gear, an epicyclic, variableratio gear
with builtin clutch, hydraulic pump and motor,
and a standard generator, see Fig. 4.01.03.
For marine engines with controllable pitch pro-
pellers running at constant engine speed, the
hydraulic system can be dispensed with, i.e. a
PTO/GCR design is normally used.
Fig. 4.01.03 shows the principles of the PTO/RCF
arrangement. As can be seen, a stepup gear box
(called crankshaft gear) with three gear wheels
is bolted directly to the frame box of the main
engine. The bearings of the three gear wheels
are mounted in the gear box so that the weight of
the wheels is not carried by the crankshaft. In the
frame box, between the crankcase and the gear
drive, space is available for tuning wheel, counter-
weights, axial vibration damper, etc.
The rst gear wheel is connected to the crank-
shaft via a special exible coupling made in one
piece with a tooth coupling driving the crankshaft
gear, thus isolating it against torsional and axial
vibrations.
By means of a simple arrangement, the shaft in
the crankshaft gear carrying the rst gear wheel
and the female part of the toothed coupling can
be moved forward, thus disconnecting the two
parts of the toothed coupling.
Operating panel
in switchboard
RCFController
Hydrostatic pump
Multidisc clutch
Toothed coupling
Servo valve
Hydrostatic motor
Toothed
coupling
Generator
Annulus ring
Sun wheel
Planetary gear wheel
Crankshaft
Elastic damping coupling
Toothed coupling
Crankshaft gear
Fig. 4.01.03: Power take off with RENK constant frequency gear: BW III/RCF, option: 4 85 253
178 23 222.1
MAN B&W 4.01
Page 5 of 6
MAN Diesel
198 43 000.2 MAN B&W K98MC/MC-C/ME/ME-C, S90MC-C/ME-C,
K90MC-C/ME/ME-C, S80MC/MC-C/ME-C, K80MC-C/ME-C,
S70MC/MCC/ME-C/ME-GI, L70MCC/ME-C, S65ME-C/ME-GI,
S60MC/MC-C/ME-C/ME-GI/ME-B, L60MC-C/ME-C,
S50MC/MC-C/ME-C/ME-B
The power from the crankshaft gear is trans-
ferred, via a multidisc clutch, to an epicyclic
variableratio gear and the generator. These are
mounted on a common bedplate, bolted to brack-
ets integrated with the engine bedplate.
The BWIII/RCF unit is an epicyclic gear with a
hydrostatic superposition drive. The hydrostatic
input drives the annulus of the epicyclic gear in
either direction of rotation, hence continuously
varying the gearing ratio to keep the genera-
tor speed constant throughout an engine speed
variation of 30%. In the standard layout, this is
between 100% and 70% of the engine speed at
specied MCR, but it can be placed in a lower
range if required.
The input power to the gear is divided into two
paths one mechanical and the other hydrostatic
and the epicyclic differential combines the
power of the two paths and transmits the com-
bined power to the output shaft, connected to the
generator. The gear is equipped with a hydrostatic
motor driven by a pump, and controlled by an
electronic control unit. This keeps the generator
speed constant during single running as well as
when running in parallel with other generators.
The multidisc clutch, integrated into the gear in-
put shaft, permits the engaging and disengaging
of the epicyclic gear, and thus the generator, from
the main engine during operation.
An electronic control system with a RENK control-
ler ensures that the control signals to the main
electrical switchboard are identical to those for
the normal auxiliary generator sets. This applies
to ships with automatic synchronising and load
sharing, as well as to ships with manual switch-
board operation.
Internal control circuits and interlocking functions
between the epicyclic gear and the electronic
control box provide automatic control of the func-
tions necessary for the reliable operation and
protection of the BWIII/RCF unit. If any monitored
value exceeds the normal operation limits, a warn-
ing or an alarm is given depending upon the ori-
gin, severity and the extent of deviation from the
permissible values. The cause of a warning or an
alarm is shown on a digital display.
Extent of delivery for BWIII/RCF units
The delivery comprises a complete unit ready to
be builton to the main engine. Fig. 4.02.01 shows
the required space and the standard electrical
output range on the generator terminals.
Standard sizes of the crankshaft gears and the
RCF units are designed for:
700, 1200, 1800 and 2600 kW, while the generator
sizes of make A. van Kaick are:
Type
DSG
440 V
1800
kVA
60 Hz
r/min
kW
380 V
1500
kVA
50 Hz
r/min
kW
62 M24 707 566 627 501
62 L14 855 684 761 609
62 L24 1,056 845 940 752
74 M14 1,271 1,017 1,137 909
74 M24 1,432 1,146 1,280 1,024
74 L14 1,651 1,321 1,468 1,174
74 L24 1,924 1,539 1,709 1,368
86 K14 1,942 1,554 1,844 1,475
86 M14 2,345 1,876 2,148 1,718
86 L24 2,792 2,234 2,542 2,033
99 K14 3,222 2,578 2,989 2,391
In the event that a larger generator is required,
please contact MAN Diesel.
If a main engine speed other than the nominal is
required as a basis for the PTO operation, it must
be taken into consideration when determining the
ratio of the crankshaft gear. However, it has no
inuence on the space required for the gears and
the generator.
The PTO can be operated as a motor (PTI) as well
as a generator by making some minor modica-
tions.
178 34 893.1
MAN B&W 4.01
Page 6 of 6
MAN Diesel
198 43 000.2 MAN B&W K98MC/MC-C/ME/ME-C, S90MC-C/ME-C,
K90MC-C/ME/ME-C, S80MC/MC-C/ME-C, K80MC-C/ME-C,
S70MC/MCC/ME-C/ME-GI, L70MCC/ME-C, S65ME-C/ME-GI,
S60MC/MC-C/ME-C/ME-GI/ME-B, L60MC-C/ME-C,
S50MC/MC-C/ME-C/ME-B
Yard deliveries are:
1. Cooling water pipes to the builton lubricating
oil cooling system, including the valves.
2. Electrical power supply to the lubricating oil
standby pump built on to the RCF unit.
3. Wiring between the generator and the operator
control panel in the switchboard.
4. An external permanent lubricating oil llingup
connection can be established in connection
with the RCF unit. The system is shown in Fig.
4.03.03 Lubricating oil system for RCF gear.
The dosage tank and the pertaining piping
are to be delivered by the yard. The size of the
dosage tank is stated in the table for RCF gear
in Necessary capacities for PTO/RCF (Fig.
4.03.02).
The necessary preparations to be made on
the engine are specied in Figs. 4.03.01a and
4.03.01b.
Additional capacities required for BWIII/RCF
The capacities stated in the List of capacities for
the main engine in question are to be increased
by the additional capacities for the crankshaft
gear and the RCF gear stated in Fig. 4.03.02.
MAN B&W 4.02
Page of
MAN Diesel
MAN B&W K98MC/ME6/7 198 43 03-6.1
The stated kW at the generator terminals is available between 70% and 00% of the engine speed at specifed MCR
Space requirements have to be investigated case by case on plants with 2600 kW generator.
Dimension H: This is only valid for A. van Kaick generator type DSG, enclosure IP23,
frequency = 60 Hz, speed = 800 r/min
Fig. 4.02.01: Space requirement for side mounted generator PTO/RCF type BWlll K98C/RCF
178 36 29-6.1


kW generator
700 kW 1200 kW 1800 kW 2600 kW
A 3,5 3,5 3,255 3,255
B 623 623 623 623
C 3,775 3,775 4,055 4,055
D 4,75 4,75 4,455 4,455
F ,673 ,793 ,93 2,023
G 2,320 2,320 2,700 2,700
H 2,70 2,680 3,070 4,380
S 400 460 550 640
System mass (kg) with generator:
27,000 3,500 44,600 6,550
System mass (kg) without generator:
25,000 28,850 40,300 56,350
MAN B&W 4.02
Page of
MAN Diesel
MAN B&W K98MC-C/ME-C6/7 198 43 24-0.1
The stated kW at the generator terminals is available between 70% and 00% of the engine speed at specifed MCR
Space requirements have to be investigated case by case on plants with 2600 kW generator.
Dimension H: This is only valid for A. van Kaick generator type DSG, enclosure IP23,
frequency = 60 Hz, speed = 800 r/min
Fig. 4.02.01: Space requirement for side mounted generator PTO/RCF type BWlll K98C/RCF
178 36 29-6.1


kW generator
700 kW 1200 kW 1800 kW 2600 kW
A 3,5 3,5 3,255 3,255
B 623 623 623 623
C 3,775 3,775 4,055 4,055
D 4,75 4,75 4,455 4,455
F ,673 ,793 ,93 2,023
G 2,320 2,320 2,700 2,700
H 2,70 2,680 3,070 4,380
S 400 460 550 640
System mass (kg) with generator:
27,000 3,500 44,600 6,550
System mass (kg) without generator:
25,000 28,850 40,300 56,350
MAN B&W 4.02
Page of
MAN Diesel
MAN B&W S90MC-C/ME-C7/8 198 43 04-8.1
The stated kW at the generator terminals is available between 70% and 00% of the engine speed at specifed MCR
Space requirements have to be investigated case by case on plants with 2600 kW generator.
Dimension H: This is only valid for A. van Kaick generator type DSG, enclosure IP23,
frequency = 60 Hz, speed = 800 r/min
Fig. 4.02.01: Space requirement for side mounted generator PTO/RCF type BWlll S90C/RCF
178 36 29-6.1


kW generator
700 kW 1200 kW 1800 kW 2600 kW
A 3,342 3,342 3,482 3,482
B 623 623 623 623
C 4,002 4,002 4,282 4,282
D 4,294 4,294 4,574 4,574
F ,673 ,793 ,93 2,023
G 3,029 3,029 3,389 3,389
H ,449 ,95 2,326 3,656
S 430 530 620 70
System mass (kg) with generator:
36,250 4,500 55,00 7,550
System mass (kg) without generator:
34,250 38,850 50,800 66,350
MAN B&W 4.02
Page of
MAN Diesel
MAN B&W K90MC-C/ME-C6 198 43 25-2.1
The stated kW at the generator terminals is available between 70% and 00% of the engine speed at specifed MCR
Space requirements have to be investigated case by case on plants with 2600 kW generator.
Dimension H: This is only valid for A. van Kaick generator type DSG, enclosure IP23,
frequency = 60 Hz, speed = 800 r/min
Fig. 4.02.01: Space requirement for side mounted generator PTO/RCF type BWlll K90C/RCF
178 36 29-6.1


kW generator
700 kW 1200 kW 1800 kW 2600 kW
A 3,568 3,568 3,708 3,708
B 623 623 623 623
C 4,228 4,228 4,508 4,508
D 4,620 4,620 4,900 4,900
F ,673 ,793 ,93 2,023
G 3,025 3,025 3,385 3,385
H ,453 ,955 2,330 3,660
S 430 530 620 70
System mass (kg) with generator:
36,250 4,500 55,00 7,550
System mass (kg) without generator:
34,250 38,850 50,800 66,350
MAN B&W 4.02
Page of
MAN Diesel
MAN B&W K90ME9 198 58 51-6.0
The stated kW at the generator terminals is available between 70% and 00% of the engine speed at specifed MCR
Space requirements have to be investigated case by case on plants with 2600 kW generator.
Dimension H: This is only valid for A. van Kaick generator type DSG, enclosure IP23,
frequency = 60 Hz, speed = 800 r/min
Fig. 4.02.01: Space requirement for side mounted generator PTO/RCF type BWlll K90/RCF
178 36 29-6.1


kW generator
700 kW 1200 kW 1800 kW 2600 kW
A 3,568 3,568 3,708 3,708
B 623 623 623 623
C 4,228 4,228 4,508 4,508
D 4,620 4,620 4,900 4,900
F ,673 ,793 ,93 2,023
G 3,025 3,025 3,385 3,385
H ,453 ,955 2,330 3,660
S 430 530 620 70
System mass (kg) with generator:
36,250 4,500 55,00 7,550
System mass (kg) without generator:
34,250 38,850 50,800 66,350
MAN B&W 4.02
Page 1 of 1
MAN Diesel
This section is available on request
for
K90ME-C9
Space requirement for side mounted PTO/RCF
198 79 84-5.0 MAN B&W K90ME-C9
MAN B&W 4.02
Page of
MAN Diesel
MAN B&W S80MC-C/ME-C7/8, S80MC6 198 43 08-5.1
The stated kW at the generator terminals is available between 70% and 00% of the engine speed at specifed MCR
Space requirements have to be investigated case by case on plants with 2600 kW generator.
Dimension H: This is only valid for A. van Kaick generator type DSG, enclosure IP23,
frequency = 60 Hz, speed = 800 r/min
Fig. 4.02.01: Space requirement for side mounted generator PTO/RCF type BWlll S80C/RCF
178 36 29-6.1


kW generator
700 kW 1200 kW 1800 kW 2600 kW
A 3,396 3,396 3,536 3,536
B 747 747 747 747
C 4,056 4,056 4,336 4,336
D 4,450 4,450 4,730 4,730
F ,797 ,97 2,037 2,47
G 2,890 2,890 3,290 3,290
H ,603 2,0 2,445 3,770
S 390 480 520 660
System mass (kg) with generator:
3,750 36,500 49,600 66,550
System mass (kg) without generator:
29,750 33,850 45,300 6,350
MAN B&W 4.02
Page of
MAN Diesel
MAN B&W K80MC-C/ME-C6 198 43 09-7.1
The stated kW at the generator terminals is available between 70% and 00% of the engine speed at specifed MCR
Space requirements have to be investigated case by case on plants with 2600 kW generator.
Dimension H: This is only valid for A. van Kaick generator type DSG, enclosure IP23,
frequency = 60 Hz, speed = 800 r/min
Fig. 4.02.01: Space requirement for side mounted generator PTO/RCF type BWlll K80C/RCF
178 36 29-6.1


kW generator
700 kW 1200 kW 1800 kW 2600 kW
A 3,255 3,255 3,395 3,395
B 747 747 747 747
C 3,95 3,95 4,95 4,95
D 4,30 4,30 4,590 4,590
F ,797 ,97 2,037 2,47
G 2,778 2,778 3,78 3,78
H ,700 2,202 2,537 3,867
S 390 480 520 660
System mass (kg) with generator:
30,750 35,500 48,00 64,550
System mass (kg) without generator:
28,750 32,850 43,800 59,350
MAN B&W 4.02
Page of
MAN Diesel
MAN B&W K80ME-C9 198 54 80-1.1
The stated kW at the generator terminals is available between 70% and 00% of the engine speed at specifed MCR
Space requirements have to be investigated case by case on plants with 2600 kW generator.
Dimension H: This is only valid for A. van Kaick generator type DSG, enclosure IP23,
frequency = 60 Hz, speed = 800 r/min
Fig. 4.02.01: Space requirement for side mounted generator PTO/RCF type BWlll K80C/RCF
178 36 29-6.1


kW generator
700 kW 1200 kW 1800 kW 2600 kW
A 3,255 3,255 3,395 3,395
B 747 747 747 747
C 3,95 3,95 4,95 4,95
D 4,30 4,30 4,590 4,590
F ,797 ,97 2,037 2,47
G 2,733 2,733 3,33 3,33
H ,745 2,392 2,647 3,92
S 390 480 570 660
System mass (kg) with generator:
30,750 35,550 48,00 64,550
System mass (kg) without generator:
28,750 32,850 43,800 59,350
MAN B&W 4.02
Page of
MAN Diesel
MAN B&W S70MC-C/ME-C/ME-GI7/8 198 43 10-7.2
The stated kW at the generator terminals is available between 70% and 00% of the engine speed at specifed MCR
Space requirements have to be investigated case by case on plants with 2600 kW generator.
Dimension H: This is only valid for A. van Kaick generator type DSG, enclosure IP23,
frequency = 60 Hz, speed = 800 r/min
Fig. 4.02.01: Space requirement for side mounted generator PTO/RCF type BWlll S70C/RCF
178 36 29-6.1


kW generator
700 kW 1200 kW 1800 kW 2600 kW
A 3,073 3,073 3,23 3,23
B 633 633 633 633
C 3,733 3,733 4,03 4,03
D 4,30 4,30 4,40 4,40
F ,683 ,803 ,923 2,033
G 2,620 2,620 3,000 3,000
H ,925 2,427 2,82 4,42
S 400 460 550 640
System mass (kg) with generator:
26,250 30,500 42,600 58,550
System mass (kg) without generator:
24,250 27,850 38,300 53,350
MAN B&W 4.02
Page of
MAN Diesel
MAN B&W L70MC-C/ME-C7/8 198 43 11-9.1
The stated kW at the generator terminals is available between 70% and 00% of the engine speed at specifed MCR
Space requirements have to be investigated case by case on plants with 2600 kW generator.
Dimension H: This is only valid for A. van Kaick generator type DSG, enclosure IP23,
frequency = 60 Hz, speed = 800 r/min
Fig. 4.02.01: Space requirement for side mounted generator PTO/RCF type BWlll L70C/RCF
178 36 29-6.1


kW generator
700 kW 1200 kW 1800 kW 2600 kW
A 2,88 2,88 3,02 3,02
B 633 633 633 633
C 3,54 3,54 3,82 3,82
D 3,940 3,940 4,220 4,220
F ,683 ,803 ,923 2,033
G 2,685 2,685 3,065 3,065
H ,803 2,305 2,690 4,020
S 400 460 550 640
System mass (kg) with generator:
25,250 29,500 4,00 56,550
System mass (kg) without generator:
23,250 26,850 36,800 5,350
MAN B&W 4.02
Page of
MAN Diesel
MAN B&W S65ME-C/ME-GI8 198 49 15-9.1
The stated kW at the generator terminals is available between 70% and 00% of the engine speed at specifed MCR
Space requirements have to be investigated case by case on plants with 2600 kW generator.
Dimension H: This is only valid for A. van Kaick generator type DSG, enclosure IP23,
frequency = 60 Hz, speed = 800 r/min
Fig. 4.02.01: Space requirement for side mounted generator PTO/RCF type BWlll S65-C/RCF
178 36 29-6.1


kW generator
700 kW 1200 kW 1800 kW 2600 kW
A 2,867 2,867 3,007 3,007
B 632 632 632 632
C 3,527 3,527 3,807 3,807
D 3,923 3,923 4,203 4,203
F ,682 ,802 ,922 2,032
G 2,470 2,470 2,830 2,830
H 2,028 2,530 2,95 4,235
S 390 450 530 620
System mass (kg) with generator:
23,750 27,500 39,00 52,550
System mass (kg) without generator:
2,750 24,850 34,800 47,350
MAN B&W 4.02
Page 1 of 1
MAN Diesel
MAN B&W S60MC-C, S60ME-C/ME-GI, S60ME-B 198 43 21-5.2
The stated kW at the generator terminals is available between 70% and 100% of the engine speed at specied MCR
Space requirements have to be investigated case by case on plants with 2600 kW generator.
Dimension H: This is only valid for A. van Kaick generator type DSG, enclosure IP23,
frequency = 60 Hz, speed = 1800 r/min
Fig. 4.02.01: Space requirement for side mounted generator PTO/RCF type BWlll S60C/RCF
178 36 29-6.1
F
D
A
B
C
H G S
kW generator
700 kW 1200 kW 1800 kW 2600 kW
A 2,684 2,684 2,824 2,824
B 632 632 632 632
C 3,344 3,344 3,624 3,624
D 3,740 3,740 4,020 4,020
F 1,682 1,802 1,922 2,032
G 2,364 2,364 2,724 2,724
H 2,134 2,636 3,021 4,341
S 390 450 530 620
System mass (kg) with generator:
23,750 27,500 39,100 52,550
System mass (kg) without generator:
21,750 24,850 34,800 47,350
MAN B&W 4.02
Page of
MAN Diesel
MAN B&W L60MC-C/ME-C7/8 198 43 13-2.1
The stated kW at the generator terminals is available between 70% and 00% of the engine speed at specifed MCR
Space requirements have to be investigated case by case on plants with 2600 kW generator.
Dimension H: This is only valid for A. van Kaick generator type DSG, enclosure IP23,
frequency = 60 Hz, speed = 800 r/min
Fig. 4.02.01: Space requirement for side mounted generator PTO/RCF type BWlll L60C/RCF
178 36 29-6.1


kW generator
700 kW 1200 kW 1800 kW 2600 kW
A 2,647 2,647 2,787 2,787
B 632 632 632 632
C 3,307 3,307 3,587 3,587
D 3,699 3,699 3,979 3,979
F ,682 ,802 ,922 2,032
G 2,39 2,39 2,75 2,75
H 2,067 2,569 2,954 4,284
S 390 480 570 620
System mass (kg) with generator:
22,750 26,500 38,00 5,050
System mass (kg) without generator:
20,750 23,850 33,800 45,850
MAN B&W 4.02
Page of
MAN Diesel
MAN B&W S50MC-C/ME-C7/8, S50ME-B8 198 43 14-4.1
The stated kW at the generator terminals is available between 70% and 00% of the engine speed at specifed MCR
Space requirements have to be investigated case by case on plants with 2600 kW generator.
Dimension H: This is only valid for A. van Kaick generator type DSG, enclosure IP23,
frequency = 60 Hz, speed = 800 r/min
Fig. 4.02.01: Space requirement for side mounted generator PTO/RCF type BWlll S50C/RCF
178 05 117.0
H G S
FORE
F
B
A
C
D
kW generator
700 kW 1200 kW 1800 kW 2600 kW
A 2,455 2,455 2,595 2,595
B 776 776 776 776
C 3,5 3,5 3,395 3,395
D 3,50 3,50 3,790 3,790
F ,826 ,946 2,066 2,76
G 2,24 2,24 2,54 2,54
H 2,289 2,79 3,96 4,526
S 380 470 500 590
System mass (kg) with generator:
22,750 26,500 37,00 48,550
System mass (kg) without generator:
20,750 23,850 32,800 43,350
MAN B&W 4.03
Page 1 of 6
MAN Diesel
198 43 156.2 MAN B&W K98MC/MC-C/ME/ME-C, S90MC-C/ME-C,
K90MC-C/ME/ME-C, S80MC/MC-C/ME-C, K80MC-C/ME-C,
S70MC/MCC/ME-C/ME-GI, L70MCC/ME-C, S65ME-C/ME-GI,
S60MC/MC-C/ME-C/ME-GI/ME-B, L60MC-C/ME-C,
S50MC/MC-C/ME-C/ME-B
Toothed coupling
Alternator
Bedframe
RCFgear
(if ordered)
Crankshaft gear
16
15
13
14
12 10 21
2
11
6
2
2
8
18
17
3 4
5
7
1
2
9
19
20
22
Fig. 4.03.01a: Engine preparations for PTO
178 57 15-7.0
Engine preparations for PTO
MAN B&W 4.03
Page 2 of 6
MAN Diesel
198 43 156.2 MAN B&W K98MC/MC-C/ME/ME-C, S90MC-C/ME-C,
K90MC-C/ME/ME-C, S80MC/MC-C/ME-C, K80MC-C/ME-C,
S70MC/MCC/ME-C/ME-GI, L70MCC/ME-C, S65ME-C/ME-GI,
S60MC/MC-C/ME-C/ME-GI/ME-B, L60MC-C/ME-C,
S50MC/MC-C/ME-C/ME-B
Pos.
1 Special face on bedplate and frame box
2 Ribs and brackets for supporting the face and machined blocks for alignment of gear or stator housing
3 Machined washers placed on frame box part of face to ensure that it is ush with the face on the bedplate
4 Rubber gasket placed on frame box part of face
5 Shim placed on frame box part of face to ensure that it is ush with the face of the bedplate
6 Distance tubes and long bolts
7 Threaded hole size, number and size of spring pins and bolts to be made in agreement with PTO maker
8 Flange of crankshaft, normally the standard execution can be used
9 Studs and nuts for crankshaft ange
10 Free ange end at lubricating oil inlet pipe (incl. blank ange)
11 Oil outlet ange welded to bedplate (incl. blank ange)
12 Face for brackets
13 Brackets
14 Studs for mounting the brackets
15 Studs, nuts and shims for mounting of RCF/generator unit on the brackets
16 Shims, studs and nuts for connection between crankshaft gear and RCF/generator unit
17 Engine cover with connecting bolts to bedplate/frame box to be used for shop test without PTO
18 Intermediate shaft between crankshaft and PTO
19 Oil sealing for intermediate shaft
20 Engine cover with hole for intermediate shaft and connecting bolts to bedplate/frame box
21 Plug box for electronic measuring instrument for checking condition of axial vibration damper
22 Tacho encoder for ME control system or Alpha lubrication system on MC engine
23 Tacho trigger ring for ME control system or Alpha lubrication system on MC engine
Pos. no: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
BWIII/RCF A A A A B A B A A A A A B B A A A
BWIII/CFE A A A A B A B A A A A A B B A A A
BWII/RCF A A A A A A A
BWII/CFE A A A A A A A
BWI/RCF A A A A B A B A A A
BWI/CFE A A A A B A B A A A A A
DMG/CFE A A A B C A B A A A
A: Preparations to be carried out by engine builder
B: Parts supplied by PTOmaker
C: See text of pos. no.
178 89 342.0
Fig. 4.03.01b: Engine preparations for PTO
MAN B&W 4.03
Page 3 of 6
MAN Diesel
198 43 156.2 MAN B&W K98MC/MC-C/ME/ME-C, S90MC-C/ME-C,
K90MC-C/ME/ME-C, S80MC/MC-C/ME-C, K80MC-C/ME-C,
S70MC/MCC/ME-C/ME-GI, L70MCC/ME-C, S65ME-C/ME-GI,
S60MC/MC-C/ME-C/ME-GI/ME-B, L60MC-C/ME-C,
S50MC/MC-C/ME-C/ME-B
Crankshaft gear lubricated from the main engine lubricating oil system
The gures are to be added to the main engine capacity list:
Nominal output of generator kW 700 1,200 1,800 2,600
Lubricating oil ow m
3
/h 4.1 4.1 4.9 6.2
Heat dissipation kW 12.1 20.8 31.1 45.0
RCF gear with separate lubricating oil system:
Nominal output of generator kW 700 1,200 1,800 2,600
Cooling water quantity m
3
/h 14.1 22.1 30.0 39.0
Heat dissipation kW 55 92 134 180
El. power for oil pump kW 11.0 15.0 18.0 21.0
Dosage tank capacity m
3
0.40 0.51 0.69 0.95
El. power for Renkcontroller 24V DC 10%, 8 amp
From main engine:
Design lube oil pressure: 2.25 bar
Lube oil pressure at crankshaft gear: min. 1 bar
Lube oil working temperature: 50 C
Lube oil type: SAE 30
Fig. 4.03.02: Necessary capacities for PTO/RCF, BW III/RCF system
178 33 850.0
Cooling water inlet temperature: 36 C
Pressure drop across cooler: approximately 0.5 bar
Fill pipe for lube oil system store tank (~32)
Drain pipe to lube oil system drain tank (~40)
Electric cable between Renk terminal at gearbox
and operator control panel in switchboard: Cable
type FMGCG 19 x 2 x 0.5
The letters refer to the List of anges,
which will be extended by the engine builder,
when PTO systems are built on the main engine
Fig. 4.03.03: Lubricating oil system for RCF gear
178 25 235.0
Filling pipe
Deck
To main engine
DR
Main
engine
Engine
oil
DS
S S
C/D
To purifier
From purifier
Lube oil
bottom tank
The dimensions
of dosage tank
depend on actual
type of gear
C/D
MAN B&W 4.03
Page 4 of 6
MAN Diesel
198 43 156.2 MAN B&W K98MC/MC-C/ME/ME-C, S90MC-C/ME-C,
K90MC-C/ME/ME-C, S80MC/MC-C/ME-C, K80MC-C/ME-C,
S70MC/MCC/ME-C/ME-GI, L70MCC/ME-C, S65ME-C/ME-GI,
S60MC/MC-C/ME-C/ME-GI/ME-B, L60MC-C/ME-C,
S50MC/MC-C/ME-C/ME-B
DMG/CFE Generators
Option: 4 85 259
Fig. 4.01.01 alternative 5, shows the DMG/CFE
(Direct Mounted Generator/Constant Frequency
Electrical) which is a low speed generator with
its rotor mounted directly on the crankshaft and
its stator bolted on to the frame box as shown in
Figs. 4.03.04 and 4.03.05.
The DMG/CFE is separated from the crankcase
by a plate and a labyrinth stufng box.
The DMG/CFE system has been developed in co-
operation with the German generator manufactur-
ers Siemens and AEG, but similar types of gene-
rator can be supplied by others, e.g. Fuji, Taiyo
and Nishishiba in Japan.
For generators in the normal output range, the
mass of the rotor can normally be carried by the
foremost main bearing without exceeding the per-
missible bearing load (see Fig. 4.03.05), but this
must be checked by the engine manufacturer in
each case.
If the permissible load on the foremost main bear-
ing is exceeded, e.g. because a tuning wheel
is needed, this does not preclude the use of a
DMG/CFE.
Fig. 4.03.04: Standard engine, with direct mounted generator (DMG/CFE)
178 06 733.1
Static frequency converter system
Synchronous
condenser
Cubicles:
Distributor
Converter
Excitation
Control
To switchboard
Cooler
Oil seal cover
Rotor
Stator housing
Support
bearing
MAN B&W 4.03
Page 5 of 6
MAN Diesel
198 43 156.2 MAN B&W K98MC/MC-C/ME/ME-C, S90MC-C/ME-C,
K90MC-C/ME/ME-C, S80MC/MC-C/ME-C, K80MC-C/ME-C,
S70MC/MCC/ME-C/ME-GI, L70MCC/ME-C, S65ME-C/ME-GI,
S60MC/MC-C/ME-C/ME-GI/ME-B, L60MC-C/ME-C,
S50MC/MC-C/ME-C/ME-B
Stator shell
Stuffing box
Crankshaft
Air cooler
Main bearing No. 1
Pole wheel
Standard engine, with direct
mounted generator (DMG/CFE)
Support
bearing
Air cooler
Pole wheel
Stator shell
Stuffing box
Crankshaft
Main bearing No. 1
Standard engine, with direct mounted
generator and tuning wheel
Tuning wheel
Fig. 4.03.05: Standard engine, with direct mounted generator and tuning wheel
178 06 637.1
Mains, constant frequency
Excitation converter
Synchronous
condenser
G
Diesel engine
DMG
Static converter
Smoothing reactor
Fig. 4.03.06: Diagram of DMG/CFE with static converter
178 56 553.1
MAN B&W 4.03
Page 6 of 6
MAN Diesel
198 43 156.2 MAN B&W K98MC/MC-C/ME/ME-C, S90MC-C/ME-C,
K90MC-C/ME/ME-C, S80MC/MC-C/ME-C, K80MC-C/ME-C,
S70MC/MCC/ME-C/ME-GI, L70MCC/ME-C, S65ME-C/ME-GI,
S60MC/MC-C/ME-C/ME-GI/ME-B, L60MC-C/ME-C,
S50MC/MC-C/ME-C/ME-B
In such a case, the problem is solved by installing
a small, elastically supported bearing in front of
the stator housing, as shown in Fig. 4.03.05.
As the DMG type is directly connected to the
crankshaft, it has a very low rotational speed and,
consequently, the electric output current has a
low frequency normally of the order of 15 Hz.
Therefore, it is necessary to use a static fre-
quency converter between the DMG and the main
switchboard. The DMG/CFE is, as standard, laid
out for operation with full output between 100%
and 70% and with reduced output between 70%
and 50% of the engine speed at specied MCR.
Static converter
The static frequency converter system (see Fig.
4.03.06) consists of a static part, i.e. thyristors and
control equipment, and a rotary electric machine.
The DMG produces a threephase alternating
current with a low frequency, which varies in ac-
cordance with the main engine speed. This alter-
nating current is rectied and led to a thyristor in-
verter producing a threephase alternating current
with constant frequency.
Since the frequency converter system uses a DC
intermediate link, no reactive power can be sup-
plied to the electric mains. To supply this reactive
power, a synchronous condenser is used. The
synchronous condenser consists of an ordinary
synchronous generator coupled to the electric
mains.
Extent of delivery for DMG/CFE units
The delivery extent is a generator fully builton
to the main engine including the synchronous
condenser unit and the static converter cubicles
which are to be installed in the engine room.
The DMG/CFE can, with a small modication,
be operated both as a generator and as a motor
(PTI).
Yard deliveries are:
1. Installation, i.e. seating in the ship for the syn-
chronous condenser unit and for the static
converter cubicles
2. Cooling water pipes to the generator if water
cooling is applied
3. Cabling.
The necessary preparations to be made on
the engine are specied in Figs. 4.03.01a and
4.03.01b.
SMG/CFE Generators
The PTO SMG/CFE (see Fig. 4.01.01 alternative 6)
has the same working principle as the PTO DMG/
CFE, but instead of being located on the front end
of the engine, the alternator is installed aft of the
engine, with the rotor integrated on the intermedi-
ate shaft.
In addition to the yard deliveries mentioned for the
PTO DMG/CFE, the shipyard must also provide
the foundation for the stator housing in the case
of the PTO SMG/CFE.
The engine needs no preparation for the installa-
tion of this PTO system.
MAN B&W 4.04
Page 1 of 3
MAN Diesel
198 43 168.6 MAN B&W S70MC/MC-C/ME-C/ME-GI, L70MC-C/ME-C,
S65MC-C/ME-C/ME-GI, S60MC/MC-C/ME-C/ME-GI/ME-B,
L60MC-C/ME-C, S50MC/MC-C/ME-C/ME-B, S46MC-C/ME-B,
S42MC, S40MC-C/ME-B, S/L35MC, S35MC-C/ME-B, S26MC
PTO type: BW II/GCR
Power Take Off/Gear Constant Ratio
The PTO system type BWII/GCR illustrated in Fig.
4.01.01 alternative 5 can generate electrical power
on board ships equipped with a controllable pitch
propeller, running at constant speed.
The PTO unit is mounted on the tank top at the
fore end of the engine see Fig. 4.04.01. The PTO
generator is activated at sea, taking over the elec-
trical power production on board when the main
engine speed has stabilised at a level correspond-
ing to the generator frequency required on board.
The installation length in front of the engine, and
thus the engine room length requirement, natu-
rally exceeds the length of the engine aft end
mounted shaft generator arrangements. However,
there is some scope for limiting the space require-
ment, depending on the conguration chosen.
PTO type: BW IV/GCR
Power Take Off/Gear Constant Ratio
The shaft generator system, type PTO BW IV/
GCR, installed in the shaft line (Fig. 4.01.01 al-
ternative 6) can generate power on board ships
equipped with a controllable pitch propeller run-
ning at constant speed.
The PTO system can be delivered as a tunnel gear
with hollow exible coupling or, alternatively, as
a generator stepup gear with thrust bearing and
exible coupling integrated in the shaft line.
The main engine needs no special preparation for
mounting these types of PTO systems as they are
connected to the intermediate shaft.
The PTO system installed in the shaft line can also
be installed on ships equipped with a xed pitch
propeller or controllable pitch propeller running in
Fig. 4.04.01: Generic outline of Power Take Off (PTO) BW II/GCR
178 18 225.0
Support bearing, if required
Elastic coupling
Step-up gear
Generator
MAN B&W 4.04
Page 2 of 3
MAN Diesel
198 43 168.6 MAN B&W S70MC/MC-C/ME-C/ME-GI, L70MC-C/ME-C,
S65MC-C/ME-C/ME-GI, S60MC/MC-C/ME-C/ME-GI/ME-B,
L60MC-C/ME-C, S50MC/MC-C/ME-C/ME-B, S46MC-C/ME-B,
S42MC, S40MC-C/ME-B, S/L35MC, S35MC-C/ME-B, S26MC
combinator mode. This will, however, require an
additional RENK Constant Frequency gear (Fig.
4.01.01 alternative 2) or additional electrical equip-
ment for maintaining the constant frequency of
the generated electric power.
Tunnel gear with hollow exible coupling
This PTO system is normally installed on ships
with a minor electrical power take off load com-
pared to the propulsion power, up to approxi-
mately 25% of the engine power.
The hollow exible coupling is only to be dimensioned
for the maximum electrical load of the power take off
system and this gives an economic advantage for minor
power take off loads compared to the system with an
ordinary exible coupling integrated in the shaft line.
The hollow exible coupling consists of exible
segments and connecting pieces, which allow
replacement of the coupling segments without
dismounting the shaft line, see Fig. 4.04.02.
Fig. 4.04.02: Generic outline of BW IV/GCR, tunnel gear
178 18 250.1
Generator stepup gear and exible coupling
integrated in the shaft line
For higher power take off loads, a generator
stepup gear and exible coupling integrated in
the shaft line may be chosen due to rst costs of
gear and coupling.
The exible coupling integrated in the shaft line
will transfer the total engine load for both propul-
sion and electrical power and must be dimen-
sioned accordingly.
The exible coupling cannot transfer the thrust
from the propeller and it is, therefore, necessary
to make the gearbox with an integrated thrust
bearing.
This type of PTO system is typically installed on
ships with large electrical power consumption,
e.g. shuttle tankers.
MAN B&W 4.04
Page 3 of 3
MAN Diesel
198 43 168.6 MAN B&W S70MC/MC-C/ME-C/ME-GI, L70MC-C/ME-C,
S65MC-C/ME-C/ME-GI, S60MC/MC-C/ME-C/ME-GI/ME-B,
L60MC-C/ME-C, S50MC/MC-C/ME-C/ME-B, S46MC-C/ME-B,
S42MC, S40MC-C/ME-B, S/L35MC, S35MC-C/ME-B, S26MC
Auxiliary Propulsion System/Take Home System
From time to time an Auxiliary Propulsion System/
Take Home System capable of driving the CP pro-
peller by using the shaft generator as an electric
motor is requested.
MAN Diesel can offer a solution where the
CP propeller is driven by the alternator via a
twospeed tunnel gear box. The electric power is
produced by a number of GenSets. The main en-
gine is disengaged by a clutch (RENK KAZ) made
as an integral part of the shafting. The clutch is in-
stalled between the tunnel gear box and the main
engine, and conical bolts are used to connect and
disconnect the main engine and the shafting.
See Figure 4.04.03.
A thrust bearing, which transfers the auxiliary pro-
pulsion propeller thrust to the engine thrust bear-
ing when the clutch is disengaged, is built into the
RENK KAZ clutch. When the clutch is engaged,
the thrust is transferred statically to the engine
thrust bearing through the thrust bearing built into
the clutch.
To obtain high propeller efciency in the auxiliary
propulsion mode, and thus also to minimise the
auxiliary power required, a twospeed tunnel gear,
which provides lower propeller speed in the auxil-
iary propulsion mode, is used.
The twospeed tunnel gear box is made with a
friction clutch which allows the propeller to be
clutched in at full alternator/motor speed where
the full torque is available. The alternator/motor is
started in the declutched condition with a start
transformer.
The system can quickly establish auxiliary propul-
sion from the engine control room and/or bridge,
even with unmanned engine room.
Reestablishment of normal operation requires
attendance in the engine room and can be done
within a few minutes.
Fig. 4.04.03: Auxiliary propulsion system
178 57 16-9.0
Main engine
Renk KAZ clutch
Twospeed tunnel gearbox
Generator/motor
Oil distribution ring
Hydraulic coupling
Intermediate bearing
Flexible coupling
MAN B&W 4.05
Page 1 of 12
MAN Diesel
MAN B&W 98-70 MC/MC-C/ME/ME-C Engine Selection Guide 198 59 12-8.3
Waste Heat Recovery Systems (WHR)
The PTG system will produce power equivalent to
approx. 4% of the main engine SMCR, when the
engine is running at SMCR. For the STG system
this value is between 5 and 7% depending on
the system installed. When combining the two
systems, a power output equivalent to 10% of the
main engines SMCR is possible, when the engine
is running at SMCR.
As the electrical power produced by the system
needs to be used on board the ship, specifying
the correct size system for a specic project must
be considered carefully. In cases where the elec-
trical power consumption on board the ship is
low, a smaller system than possible for the engine
type may be considered. Another possibility is to
install a shaft generator/motor to absorb excess
power produced by the WHR. The main engine
will then be unloaded, or it will be possible to in-
crease the speed of the ship, without penalising
the fuelbill.
Because the energy from WHR is taken from
the exhaust gas of the main engine, this power
produced can be considered as free. In reality,
the main engine SFOC will increase slightly, but
the gain in electricity production on board the
ship will far surpass this increase in SFOC. As an
example, the SFOC of the combined output of
both the engine and the system with power and
steam turbine can be calculated to be as low as
155 g/kWh (ref. LCV 42,700 kJ/kg).
Due to the increasing fuel prices seen from 2004
and onwards many shipowners have shown inter-
est in efciency improvements of the power sys-
tems on board their ships. A modern two-stroke
diesel engine has one of the highest thermal ef-
ciencies of todays power systems, but even this
high efciency can be improved by combining the
diesel engine with other power systems.
One of the possibilities for improving the efcien-
cy is to install one or more systems utilising some
of the energy in the exhaust gas after the two-
stroke engine, which in MAN Diesel terms is des-
ignated as WHR (Waste Heat Recovery Systems).
WHR can be divided into different types of sub-
systems, depending on how the system utilises
the exhaust gas energy. Choosing the right sys-
tem for a specic project depends on the electric-
ity demand on board the ship and the acceptable
rst cost for the complete installation. MAN Diesel
uses the following designations for the current
systems on the market:
PTG (Power Turbine Generator):
An exhaust gas driven turbine connected to a
generator via a gearbox.
STG (Steam Turbine Generator):
A steam driven turbine connected to a generator
via a gearbox. The steam is produced in a large
exhaust gas driven boiler installed on the main
engine exhaust gas piping system.
Combined Turbines:
A combination of the two rst systems. The ar-
rangement is often that the power turbine is
connected to the steam turbine via a gearbox
and the steam turbine is further connected to a
large generator, which absorbs the power from
both turbines.
MAN B&W 4.05
Page 2 of 12
MAN Diesel
MAN B&W 98-70 MC/MC-C/ME/ME-C Engine Selection Guide 198 59 12-8.3
Gen.Set
Gen.Set
Shaft
generator/
motor
Main engine
Exhaust gas receiver
Power
turbine
To funnel
Gearbox
Main
switchboard
Butterfly
valve
Quick
closing
valve
Quick
closing
valve
Quick
opening
valve
Pipe
Electrical wiring
PTG
The power turbines of today are based on the
different turbocharger suppliers newest designs
of high-efcient turbochargers, i.e. MAN Diesels
TCA, ABBs TPL and Mitsubishis MA turbocharg-
ers. The power turbine basically, is the turbine
side of a normal high-efcient turbocharger with
some modications to the bearings and the tur-
bine shaft, in order to be able to connect it to a
gearbox instead of the normal connection to the
compressor side. The power turbine will be in-
stalled on a separate exhaust gas pipe from the
exhaust gas receiver, which bypasses the turbo-
chargers. The performance of the PTG and the
main engine will depend on a careful matching of
the engine turbochargers and the power turbine,
which means that the turbocharger/s and the
power turbine need to be from the same manu-
facturer. In Fig. 4.05.01, a simple diagram of the
PTG arrangement is shown. The quick-opening
and quick-closing valves are used in the event of
a black out on the grid, in which case the exhaust
gas will bypass the power turbine.
The newest generation of high-efcient turbo-
chargers allows bypassing of some of the main
engine exhaust gas, thereby creating a new bal-
ance of the air ow through the engine. In this
way, it is possible to extract power from the power
turbine equivalent of 4% of the main engines
SMCR, when the engine is running at SMCR.
178 57 09-8.0
Fig. 4.05.01: PTG diagram
MAN B&W 4.05
Page 3 of 12
MAN Diesel
MAN B&W 98-70 MC/MC-C/ME/ME-C Engine Selection Guide 198 59 12-8.3
Width
D
Reduction gear
Power turbine Generator
C
A
Maintenance space
B
178 56 95-2.0
Fig. 4.05.02: The size a 1,000 kW PTG system depending on the supplier
PTG-system A B C D
size m m m m
1,000 4,0 - 4.5 2.5 - 3.0 2.5 2.0
1,500 4.5 - 5.0 2.0 - 2.5 2.5 2.0
2,000 5,0 - 5.5 2.5 - 3.0 2.5 2.0 - 2.5
3,000 5.5 - 7,0 3.0 - 4.0 3.0 - 3.5 2.2 - 3.5
4,500 6,0 - 7.5 3.0 - 4.0 3.5 - 4.0 2.3 - 3.5
MAN B&W 4.05
Page 4 of 12
MAN Diesel
MAN B&W 98-70 MC/MC-C/ME/ME-C Engine Selection Guide 198 59 12-8.3
STG
In most cases the exhaust gas pipe system of
the main engine is equipped with a boiler system.
With this boiler, some of the energy in the exhaust
gas is utilised to produce steam for use on board
the ship. If the engine is WHR matched, the ex-
haust gas temperature will be between 50C and
65C higher than on a conventional engine, which
makes it possible to install a larger boiler sys-
tem and, thereby, produce more steam. In short,
MAN Diesel designates this system as STG. Fig.
4.05.03 shows an example of the arrangement of
STG. For WHR matching the engine, a bypass is
installed to increase the temperature of the ex-
haust gas and improve the boiler output.
Gen.Set
Gen.Set
Gen.Set
Shaft
Generator/
Motor
Main engine
Exhaust gas receiver
Economiser
Steam
turbine
LP steam
Condenser
HP steam
Hotwell
To funnel
Cooling
Water
Gearbox
Steam
regulating
valve
Feedwater
pump
To economiser
Pipe
Electrical wiring
Steam
Main switchboard
Butterfly
Valve
The extra steam produced in the boiler can be
utilised in a steam turbine, which can be used to
drive a generator for power production on board
the ship. An STG system could be arranged as
shown in Fig. 4.05.04, where a typical system size
is shown with the outline dimensions. The steam
turbine can either be a single or dual pressure tur-
bine, depending on the size of the system. Steam
pressures for a single pressure system is 7 to 10
bara, and for the dual pressure system, the high-
pressure cycle will be 9 to 10 bara and the low-
pressure cycle will be 4 to 5 bara.
178 56 96-4.0
Fig. 4.05.03: Steam diagram
MAN B&W 4.05
Page 5 of 12
MAN Diesel
MAN B&W 98-70 MC/MC-C/ME/ME-C Engine Selection Guide 198 59 12-8.3
Width
G
Condensate pump
Condenser Expansion joint
Steam turbine Reduction gear Generator
F
A
Maintenance space
B
O
v
e
r
h
a
u
l

h
e
i
g
h
t
C
Maintenance space
E
D
178 57 02-5.0
Fig. 4.05.04: Typical system for 1,000 kW STG system
PTG-system A B C D E F G
size m m m m m m m
1,000 4.5 - 5.0 2.0 - 2.5 3.5 - 4.0 3.0 - 4.0 3.0 - 4.0 3.0 - 4.0 2.5 - 3.0
1,500 5.5 - 7.5 2.5 - 3.0 3.5 - 4.0 4.5 - 5.5 4.0 - 5.0 5.5 - 6.5 2.5 - 3.0
2,000 7.0 - 9.0 3.0 - 4.0 4.8 - 5.1 5.0 - 6.0 4.5 - 5.0 7.0 - 8.0 2.8 - 3.3
3,000 7.0 - 9.0 3.0 - 4.0 4.8 - 5.1 5.0 - 6.0 5.0 - 5.5 8.0 - 9.0 3.0 - 3.5
5,000 8.0 -10.0 3.5 - 4.5 4.8 - 5.1 5.5 - 6.5 5.0 - 6.5 9.0 -10.0 3.5 - 4.0
MAN B&W 4.05
Page 6 of 12
MAN Diesel
MAN B&W 98-70 MC/MC-C/ME/ME-C Engine Selection Guide 198 59 12-8.3
Combined Turbines
Because the installation of the power turbine also
will result in an increase the exhaust gas tempera-
ture after the turbochargers, it is possible to in-
stall both the power turbine, the larger boiler and
steam turbine on the same engine. This means
that the energy from the exhaust gas is utilised in
the best way possible by todays components.
When looking at the system with both power and
steam turbine, it will often be the case that power
turbine and steam turbine are connected to the
same generator. In some cases, it is also possible
to have each turbine on a separate generator,
though mostly seen on stationary engines, where
the frequency control is simpler because of the
large grid that the generator can lean against.
For marine installations the power turbine is, in
most cases, connected to the steam turbine via a
gearbox, and the steam turbine is then connected
to the generator. It is also possible to have a gen-
erator with connections in both ends, and then
connect the power turbine in the one end and the
steam turbine in the other end. In both cases con-
trol of one generator only is needed.
For dimensions of a typical system see
Fig. 4.05.06.
As mentioned, the systems with steam turbines
require a larger boiler to be installed. The size
of the boiler system will be roughly three to four
times the size of an ordinary boiler system, but
the actual boiler size has to be calculated from
case to case.
Gen.Set
Gen.Set
Shaft
generator/
motor
Main engine
Exhaust gas receiver
Economiser
Steam
turbine
LP steam
Condenser
HP steam
To funnel
Cooling
water
Gearbox
To economiser
Feedwater
pump
Hotwell
Gearbox
Main switchboard
Power
turbine
Steam
regulating
valve
Butterfly
valve
Quick
Opening
Valve
Quick closing valve
Quick
closing
valve
Pipe
Electrical wiring
Steam
178 57 03-7.0
Fig. 4.05.05: Combined turbines diagram
MAN B&W 4.05
Page 7 of 12
MAN Diesel
MAN B&W 98-70 MC/MC-C/ME/ME-C Engine Selection Guide 198 59 12-8.3
Width:
G
Condensate pump
Condenser
Expansion joint
Reduction gear
Power turbine Steam turbine Reduction gear Generator
D
A
F
Maintenance space
B
Maintenance space
E
O
v
e
r
h
a
u
l

h
e
i
g
h
t

C
178 57 08-6.0
Fig. 4.05.06: Typical system
PTG-system A B C D E F G
size m m m m m m m
1,500 7.5 - 8.0 2.0 - 2.5 3.5 - 4.0 3.0 - 4.0 3.0 - 4.0 3.0 - 4.0 2.5 - 3.0
3,000 8.5 - 10.5 3.0 - 4.0 3.5 - 4.0 4.5 - 5.5 4.0 - 5.0 5.5 - 6.5 2.5 - 3.0
4,000 10.0 - 12.0 3.0 - 4.0 4.8 - 5.1 5.0 - 6.0 4.5 - 5.5 6.0 - 7.0 2.8 - 3.3
7,000 10.0 - 12.0 3.5 - 4.5 4.8 - 5.1 5.0 - 6.0 5.0 - 5.5 8.0 - 9.0 3.0 - 3.5
8,500 11.0 - 13.0 3.5 - 4.5 4.8 - 5.1 5.5 - 6.5 5.5 - 6.5 9.0 -10.0 3.5 - 4.0
MAN B&W 4.05
Page 8 of 12
MAN Diesel
MAN B&W 98-70 MC/MC-C/ME/ME-C Engine Selection Guide 198 59 12-8.3
WHR output
Because all the components come from different
manufacturers, the nal output and the system
efciency has to be calculated from case to case.
However, Fig. 4.05.07 shows a guidance of pos-
sible outputs based on theoretically calculated
outputs from the system.
Detailed information on the different systems
is found in our paper Thermo Efciency Sys-
tem, where the different systems are described
in greater detail. The paper is available at:
www.mandieselturbo.com under Products
Marine Engines & Systems Low Speed
Technical Papers, from where it can be down-
loaded.
Guidance output of WHR for K98ME/MC7 engine rated in L1 at ISO conditions
Cyl.
Engine power PTG STG Combined Turbines
% SMCR kWe kWe kWe
6
100 1,467 2,241 3,411
80 936 1,593 2,277
7
100 1,719 2,619 3,987
80 1,098 1,863 2,664
8
100 1,962 3,006 4,572
80 1,251 2,133 3,060
9
100 2,214 3,393 5,157
80 1,413 2,412 3,456
10
100 2,466 3,780 5,742
80 1,566 2,691 3,843
11
100 2,709 4,158 6,309
80 1,728 2,952 4,239
12
100 2,961 4,545 6,912
80 1,890 3,231 4,635
14
100 3,456 5,319 8,082
80 2,205 3,789 5,418
MAN B&W 4.05
Page 9 of 12
MAN Diesel
MAN B&W 98-70 MC/MC-C/ME/ME-C Engine Selection Guide 198 59 12-8.3
Guidance output of WHR for K98MC-C/ME-C7 engine rated in L1 at ISO conditions
Cyl.
Engine power PTG STG Combined Turbines
% SMCR kWe kWe kWe
6
100 1,422 2,178 3,312
80 909 1,548 2,214
7
100 1,656 2,547 3,870
80 1,053 1,809 2,583
8
100 1,899 2,925 4,428
80 1,206 2,079 2,961
9
100 2,142 3,303 5,004
80 1,359 2,340 3,348
10
100 2,376 3,672 5,571
80 1,512 2,610 3,735
11
100 2,619 4,050 6,138
80 1,665 2,880 4,113
12
100 2,862 4,428 6,696
80 1,818 3,150 4,491
14
100 3,339 5,175 7,830
80 2,133 3,690 5,256
Guidance output of WHR for S90MC-C/ME-C8 engine rated in L1 at ISO conditions
Cyl.
Engine power PTG STG Combined Turbines
% SMCR kWe kWe kWe
6
100 1,242 1,800 2,799
80 792 1,269 1,872
7
100 1,449 2,115 3,276
80 927 1,494 2,187
8
100 1,656 2,421 3,753
80 1,053 1,719 2,502
9
100 1,872 2,736 4,239
80 1,188 1,944 2,835
MAN B&W 4.05
Page 10 of 12
MAN Diesel
MAN B&W 98-70 MC/MC-C/ME/ME-C Engine Selection Guide 198 59 12-8.3
Guidance output of WHR for K90ME-C9 engine rated in L1 at ISO conditions
Cyl.
Engine power PTG STG Combined Turbines
% SMCR kWe kWe kWe
6
100 1,350 2,115 3,195
80 864 1,512 2,151
7
100 1,575 2,475 3,735
80 1,008 1,773 2,520
8
100 1,809 2,853 4,293
80 1,152 2,034 2,889
9
100 2,034 3,213 4,833
80 1,296 2,295 3,249
10
100 2,259 3,573 5,382
80 1,440 2,547 3,618
11
100 2,493 3,942 5,931
80 1,584 2,817 3,996
12
100 2,718 4,302 6,471
80 1,737 3,078 4,356
Guidance output of WHR for S80MC-C/ME-C8 engine rated in L1 at ISO conditions
Cyl.
Engine power PTG STG Combined Turbines
% SMCR kWe kWe kWe
6
100 981 1,440 2,223
80 630 1,017 1,485
7
100 1,152 1,683 2,601
80 729 1,188 1,728
8
100 1,314 1,926 2,979
80 837 1,368 1,989
Guidance output of WHR for S80ME-C9 engine rated in L1 at ISO conditions
Cyl.
Engine power PTG STG Combined Turbines
% SMCR kWe kWe kWe
6
100 1,062 1,575 2,430
80 675 1,116 1,629
7
100 1,242 1,854 2,853
80 792 1,323 1,917
8
100 1,422 2,124 3,267
80 900 1,512 2,187
9
100 1,593 2,394 3,681
80 1,017 1,701 2,466
MAN B&W 4.05
Page 11 of 12
MAN Diesel
MAN B&W 98-70 MC/MC-C/ME/ME-C Engine Selection Guide 198 59 12-8.3
Guidance output of WHR for K80MC-C/ME-C6 engine rated in L1 at ISO conditions
Cyl.
Engine power PTG STG Combined Turbines
% SMCR kWe kWe kWe
6
100 846 1,269 1,944
80 540 891 1,296
7
100 990 1,485 2,277
80 630 1,044 1,512
8
100 1,134 1,710 2,619
80 720 1,215 1,746
9
100 1,278 1,935 2,943
80 810 1,368 1,962
10
100 1,422 2,160 3,294
80 900 1,539 2,196
11
100 1,566 2,376 3,618
80 999 1,683 2,421
12
100 1,710 2,601 3,960
80 1,089 1,845 2,646
Guidance output of WHR for K80ME-C9 engine rated in L1 at ISO conditions
Cyl.
Engine power PTG STG Combined Turbines
% SMCR kWe kWe kWe
6
100 1,062 1,647 2,502
80 675 1,179 1,683
7
100 1,242 1,935 2,925
80 792 1,377 1,962
8
100 1,422 2,223 3,357
80 909 1,584 2,259
9
100 1,602 2,502 3,789
80 1,026 1,791 2,547
10
100 1,782 2,790 4,221
80 1,134 1,989 2,835
11
100 1,962 3,078 4,644
80 1,251 2,196 3,123
12
100 2,142 3,366 5,085
80 1,368 2,403 3,420
MAN B&W 4.05
Page 12 of 12
MAN Diesel
MAN B&W 98-70 MC/MC-C/ME/ME-C Engine Selection Guide 198 59 12-8.3
Guidance output of WHR for S70MC-C/ME-C8 engine rated in L1 at ISO conditions
Cyl.
Engine power PTG STG Combined Turbines
% SMCR kWe kWe kWe
5
100 639 918 1,422
80 405 639 945
6
100 765 1,116 1,728
80 486 783 1,143
7
100 900 1,305 2,025
80 567 927 1,350
8
100 1,026 1,494 2,322
80 657 1,053 1,539
Guidance output of WHR for L70MC-C/ME-C8 engine rated in L1 at ISO conditions
Cyl.
Engine power PTG STG Combined Turbines
% SMCR kWe kWe kWe
5
100 639 918 1,422
80 405 639 945
6
100 765 1,116 1,728
80 486 783 1,143
7
100 900 1,305 2,025
80 567 927 1,350
8
100 1,026 1,494 2,322
80 657 1,053 1,539
Table 4.05.07: Theoretically calculated outputs
MAN B&W
Page 1 of 1
MAN Diesel
This section is not applicable
for
65-26 MC/MC-C/ME-C/ME-C-GI/ME-B
Waste Heat Recovery Systems (WHR)
4.05
198 79 59-5.0 MAN B&W S65ME-C/-GI, S60MC/MC-C/ME-C/ME-C-GI/ME-B,
L60MC-C/ME-C, S50MC/MC-C/ME-C/ME-B, S46MC-C/ME-B,
S42MC, S40MC-C/ME-B, S35MC/MC-C/ME-B, L35MC, S26MC
MAN Diesel 4.06
Page 1 of 3
MAN Diesel
198 42 054.5 MAN B&W S80MC/MC-C/ME-C, K80MC-C/ME-C, S70MC/MC-C/ME-C/ME-GI,
L70MC-C/ME-C, S65ME-C/ME-GI, S60MC/MC-C/ME-C/ME-GI/ME-B,
L60MC-C/ME-C, S50MC/MC-C/ME-C/ME-B, S46MC-C/ME-B, S42MC,
S40MC-C/ME-B, S35MC/MC-C/ME-B, L35MC, S26MC
L16/24 GenSet Data
Bore: 160 mm Stroke: 240 mm
Power layout
1,200 r/min 60 Hz 1,000 r/min 50 Hz
Eng. kW Gen. kW Eng. kW Gen. kW
5L16/24 500 475 450 430
6L16/24 660 625 570 542
7L16/24 770 730 665 632
8L16/24 880 835 760 722
9L16/24 990 940 855 812
No. of Cyls. A (mm) * B (mm) * C (mm) H (mm)
**Dry weight
GenSet (t)
5 (1,000 r/min) 2,751 1,400 4,151 2,457 9.5
5 (1,200 r/min) 2,751 1,400 4,151 2,457 9.5
6 (1,000 r/min) 3,026 1,490 4,516 2,457 10.5
6 (1,200 r/min) 3,026 1,490 4,516 2,457 10.5
7 (1,000 r/min) 3,501 1,585 5,086 2,457 11.4
7 (1,200 r/min) 3,501 1,585 5,086 2,457 11.4
8 (1,000 r/min) 3,776 1,680 5,456 2,495 12.4
8 (1,200 r/min) 3,776 1,680 5,456 2,457 12.4
9 (1,000 r/min) 4,151 1,680 5,731 2,495 13.1
9 (1,200 r/min) 4,151 1,680 5,731 2,495 13.1
178 23 031.0
P Free passage between the engines, width 600 mm and height 2,000 mm
Q Min. distance between engines: 1,800 mm
* Depending on alternator
** Weight incl. standard alternator (based on a Leroy Somer alternator)
All dimensions and masses are approximate and subject to change without prior notice.
178 33 874.3
Fig. 4.06.01: Power and outline of L16/24
A
C
B
H
P
Q
830 1000
MAN Diesel 4.06
Page 2 of 3
MAN Diesel
MAN B&W S80MC/MC-C/ME-C, K80MC-C/ME-C, S70MC/MC-C/ME-C/ME-GI,
L70MC-C/ME-C, S65ME-C/ME-GI, S60MC/MC-C/ME-C/ME-GI/ME-B,
L60MC-C/ME-C, S50MC/MC-C/ME-C/ME-B, S46MC-C/ME-B, S42MC,
S40MC-C/ME-B, S35MC/MC-C/ME-B, L35MC, S26MC
198 42 054.5
L16/24 GenSet Data
Fig. 4.06.02a: List of capacities for L16/24 1,000 rpm, IMO Tier I. Tier II values available on request.
178 56 53-3.0
Cyl. 5 6 7 8 9
Max. continuous rating at 1,000 rpm kW 450 540 630 720 810
Engine Driven Pumps:
H.T. cooling water pump (2.0 bar)** m
3
/h 10.9 12.7 14.5 16.3 18.1
L.T. cooling water pump (1.7 bar)** m
3
/h 15.7 18.9 22.0 25.1 28.3
Lubricating oil (3-5.0 bar) m
3
/h 21 23 24 26 28
External Pumps:
Diesel oil pump (5 bar at fuel oil inlet A1) m/h 0.31 0.38 0.44 0.50 0.57
Fuel oil supply pump (4 bar discharge pressure) m/h 0.15 0.18 0.22 0.25 0.28
Fuel oil circulating pump (8 bar at fuel oil inlet A1) m/h 0.32 0.38 0.45 0.51 0.57
Cooling Capacities:
Lubricating oil kW 79 95 110 126 142
Charge air L.T. kW 43 51 60 68 77
*Flow L.T. at 36C inlet and 44C outlet m
3
/h 13.1 15.7 18.4 21.0 23.6
Jacket cooling kW 107 129 150 171 193
Charge air H.T kW 107 129 150 171 193
Gas Data:
Exhaust gas ow kg/h 3,321 3,985 4,649 5,314 5,978
Exhaust gas temp. C 330 330 330 330 330
Max. allowable back press. bar 0.025 0.025 0.025 0.025 0.025
Air consumption kg/h 3,231 3,877 4,523 5,170 5,816
Starting Air System:
Air consumption per start Nm 0.47 0.56 0.65 0.75 0.84
Air consumption per start Nm 0.80 0.96 1.12 1.28 1.44
Heat Radiation:
Engine kW 11 13 15 17 19
Alternator kW (see separate data from the alternator maker)
The stated heat balances are based on tropical conditions, the ows are based on ISO ambient condition.
* The outlet temperature of the H.T. water is xed to 80C, and
44C for L.T. water. At different inlet temperatures the ow will
change accordingly.
Example: if the inlet temperature is 25C, then the L.T. ow will
change to (44-36)/(44-25)*100 = 42% of the original ow. If the
temperature rises above 36C, then the L.T. outlet will rise ac-
cordingly.
** Max. permission inlet pressure 2.0 bar.
MAN Diesel 4.06
Page 3 of 3
MAN Diesel
198 42 054.5 MAN B&W S80MC/MC-C/ME-C, K80MC-C/ME-C, S70MC/MC-C/ME-C/ME-GI,
L70MC-C/ME-C, S65ME-C/ME-GI, S60MC/MC-C/ME-C/ME-GI/ME-B,
L60MC-C/ME-C, S50MC/MC-C/ME-C/ME-B, S46MC-C/ME-B, S42MC,
S40MC-C/ME-B, S35MC/MC-C/ME-B, L35MC, S26MC
Cyl. 5 6 7 8 9
Max continues rating 1,200 rpm kW 500 660 770 880 990
Engine driven pumps:
LT cooling water pump 2 bar m/h 27 27 27 27 27
HT cooling water pump 2 bar m/h 27 27 27 27 27
Lubricating oil main pump 8 bar m/h 21 21 35 35 35
Separate pumps:
Max. Delivery pressure of cooling water pumps bar 2.5 2.5 2.5 2.5 2.5
Diesel oil pump (5 bar at fuel oil inlet A1) m/h 0.35 0.46 0.54 0.61 0.69
Fuel oil supply pump (4 bar discharge pressure) m/h 0.17 0.22 0.26 0.30 0.34
Fuel oil circulating pump (8 bar at fuel oil inlet A1) m/h 0.35 0.46 0.54 0.62 0.70
Cooling capacity:
Lubricating oil kW 79 103 122 140 159
Charge air LT kW 40 57 70 82 95
Total LT system kW 119 160 192 222 254
Flow LT at 36C inlet and 44C outlet m/h 13 17 21 24 27
Jacket cooling kW 119 162 191 220 249
Charge air HT kW 123 169 190 211 230
Total HT system kW 242 331 381 431 479
Flow HT at 44Cinlet and 80C outlet m/h 6 8 9 10 11
Total from engine kW 361 491 573 653 733
LT ow at 36C inlet m/h 13 17 21 24 27
LT temp. Outlet engine
(at 36C and 1 string cooling water system)
C 60 61 60 60 59
Gas Data:
Exhaust gas ow kg/h 3,400 4,600 5,500 6,200 7,000
Exhaust gas temp. C 330 340 340 340 340
Max. Allowable back press. bar 0.025 0.025 0.025 0.025 0.025
Air consumption kg/h 3,280 4,500 5,300 6,000 6,800
Starting Air System:
Air consumption per start Nm 0.47 0.56 0.65 0.75 0.84
Air consumption per start Nm 0.80 0.96 1.12 1.28 1.44
Heat Radiation:
Engine kW 9 13 15 18 21
Alternator kW (see separate data from the alternator maker)
The stated heat balances are based on tropical conditions. The exhaust gas data (exhaust gas ow, exhaust gas temp.
and air consumption). are based on ISO ambient condition.
* The outlet temperature of the HT water is xed to 80C, and 44C for the LT water
At different inlet temperature the ow will change accordingly.
Example: If the inlet temperature is 25C then the LT ow will change to (44-36)/(44-25)*100 = 42% of the original ow.
If the temperature rises above 36C, then the L.T. outlet will rise acordingly.
L16/24 GenSet Data
Fig. 4.06.02b: List of capacities for L16/24 1,200 rpm, IMO Tier I. Tier II values available on request.
MAN Diesel 4.07
Page 1 of 3
MAN Diesel
198 42 066.5 MAN B&W S80MC/MC-C/ME-C, K80MC-C/ME-C, S70MC/MC-C/ME-C/ME-GI,
L70MC-C/ME-C, S65ME-C/ME-GI, S60MC/MC-C/ME-C/ME-GI/ME-B,
L60MC-C/ME-C, S50MC/MC-C/ME-C/ME-B, S46MC-C/ME-B, S42MC,
S40MC-C/ME-B, S35MC/MC-C/ME-B, L35MC, S26MC
L21/31 GenSet Data
Bore: 210 mm Stroke: 310 mm
Power layout
900 r/min 60 Hz 1,000 r/min 50 Hz
Eng. kW Gen. kW Eng. kW Gen. kW
5L21/31 1,000 950 1,000 950
6L21/31 1,320 1,254 1,320 1,254
7L21/31 1,540 1,463 1,540 1,463
8L21/31 1,760 1,672 1,760 1,672
9L21/31 1,980 1,881 1,980 1,881
178 23 043.2
Fig. 4.07.01: Power and outline of L21/31
P
1,200
1,400
H
Q
A B
C
P Free passage between the engines, width 600 mm and height 2000 mm.
Q Min. distance between engines: 2400 mm (without gallery) and 2600 mm (with galley)
* Depending on alternator
** Weight incl. standard alternator (based on a Uljanik alternator)
All dimensions and masses are approximate, and subject to changes without prior notice.
Cyl. no A (mm) * B (mm) * C (mm) H (mm)
**Dry weight
GenSet (t)
5 (900 rpm) 3,959 1,820 5,829 3,183 21.5
5 (1000 rpm) 3,959 1,870 5,829 3,183 21.5
6 (900 rpm) 4,314 2,000 6,314 3,183 23.7
6 (1000 rpm) 4,314 2,000 6,314 3,183 23.7
7 (900 rpm) 4,669 1,970 6,639 3,183 25.9
7 (1000 rpm) 4,669 1,970 6,639 3,183 25.9
8 (900 rpm) 5,024 2,250 7,274 3,289 28.5
8 (1000 rpm) 5,024 2,250 7,274 3,289 28.5
9 (900 rpm) 5,379 2,400 7,779 3,289 30.9
9 (1000 rpm) 5,379 2,400 7,779 3,289 30.9
MAN Diesel 4.07
Page 2 of 3
MAN Diesel
198 42 066.5 MAN B&W S80MC/MC-C/ME-C, K80MC-C/ME-C, S70MC/MC-C/ME-C/ME-GI,
L70MC-C/ME-C, S65ME-C/ME-GI, S60MC/MC-C/ME-C/ME-GI/ME-B,
L60MC-C/ME-C, S50MC/MC-C/ME-C/ME-B, S46MC-C/ME-B, S42MC,
S40MC-C/ME-B, S35MC/MC-C/ME-B, L35MC, S26MC
Fig. 4.07.02a: List of capacities for L21/31, 900 rpm, IMO Tier I. Tier II values available on request.
L21/31 GenSet Data
Cyl. 5 6 7 8 9
Maximum continuous rating at 900 rpm kW 950 1,320 1,540 1,760 1,980
Engine-driven pumps:
LT cooling water pump (1-2.5 bar) m/h 55 55 55 55 55
HT cooling water pump (1-2.5 bar) m/h 55 55 55 55 55
Lubricating oil pump (3-5 bar) m/h 31 31 41 41 41
External pumps:
Max. delivery pressure of cooling water pumps bar 2.5 2.5 2.5 2.5 2.5
Diesel oil pump (5 bar at fuel oil inlet A1) m/h 0.65 0.91 1.06 1.21 1.36
Fuel oil supply pump (4 bar discharge pressure) m/h 0.32 0.44 0.52 0.59 0.67
Fuel oil circulating pump (8 bar at fuel oil inlet A1) m/h 0.66 0.92 1.07 1.23 1.38
Cooling capacities:
Lubricating oil kW 195 158 189 218 247
LT charge air kW 118 313 366 418 468
Total LT system kW 313 471 555 636 715
LT ow at 36C inlet and 44C outlet* m/h 27.0 44.0 48.1 51.9 54.0
Jacket cooling kW 154 274 326 376 427
HT charge air kW 201 337 383 429 475
Total HT system kW 355 611 709 805 902
HT ow at 44C inlet and 80C outlet* m/h 8.5 19.8 22.6 25.3 27.9
Total from engine kW 668 1082 1264 1441 1617
LT ow from engine at 36C inlet m/h 27.0 43.5 47.6 51.3 53.5
LT outlet temperature from engine at 36C inlet C 55 58 59 61 63
( 1-string cooling water system )
Gas data:
Exhaust gas ow kg/h 6,679 9,600 11,200 12,800 14,400
Exhaust gas temperature at turbine outlet C 335 348 348 348 348
Maximum allowable back pressure bar 0.025 0.025 0.025 0.025 0.025
Air consumption kg/h 6,489 9,330 10,900 12,400 14,000
Starting air system:
Air consumption per start incl. air for jet assist Nm 1.0 1.2 1.4 1.6 1.8
Heat radiation:
Engine kW 49 50 54 58
Alternator kW ( See separate data from alternator maker )
The stated heat balances are based on 100% load and tropical
condition.
The mass ows and exhaust gas temperature are based on ISO
ambient condition.
* The outlet temperature of the HT water is xed to 80C, and
44C for the LT water.
At different inlet temperature the ow will change accordingly.
Example: If the inlet temperature is 25C then the LT ow will
change to (44-36)/(44-25)*100 = 42% of the original ow.
The HT ow will not change.
17856 53-3.0
MAN Diesel 4.07
Page 3 of 3
MAN Diesel
198 42 066.5 MAN B&W S80MC/MC-C/ME-C, K80MC-C/ME-C, S70MC/MC-C/ME-C/ME-GI,
L70MC-C/ME-C, S65ME-C/ME-GI, S60MC/MC-C/ME-C/ME-GI/ME-B,
L60MC-C/ME-C, S50MC/MC-C/ME-C/ME-B, S46MC-C/ME-B, S42MC,
S40MC-C/ME-B, S35MC/MC-C/ME-B, L35MC, S26MC
L21/31 GenSet Data
Fig. 4.07.02a: List of capacities for L21/31, 1,000 rpm, IMO Tier I. Tier II values available on request.
Cyl. 5 6 7 8 9
Maximum continuous rating at 1000 rpm kW 1,000 1,320 1,540 1,760 1,980
Engine-driven pumps:
LT cooling water pump (1-2.5 bar) m/h 61 61 61 61 61
HT cooling water pump (1-2.5 bar) m/h 61 61 61 61 61
Lubricating oil pump (3-5 bar) m/h 34 34 46 46 46
External pumps:
Max. delivery pressure of cooling water pumps bar 2.5 2.5 2.5 2.5 2.5
Diesel oil pump (5 bar at fuel oil inlet A1) m/h 0.69 0.92 1.08 1.23 1.38
Fuel oil supply pump (4 bar discharge pressure) m/h 0.34 0.45 0.53 0.60 0.68
Fuel oil circulating pump (8 bar at fuel oil inlet A1) m/h 0.70 0.93 1.09 1.25 1.40
Cooling capacities:
Lubricating oil kW 206 162 192 222 252
LT charge air kW 125 333 388 443 499
Total LT system kW 331 495 580 665 751
LT ow at 36C inlet and 44C outlet* m/h 35.5 47.8 52.1 56.2 60.5
Jacket cooling kW 163 280 332 383 435
HT charge air kW 212 361 411 460 509
Total HT system kW 374 641 743 843 944
HT ow at 44C inlet and 80C outlet* m/h 8.9 20.9 23.9 26.7 29.5
Total from engine kW 705 1136 1323 1508 1695
LT ow from engine at 36C inlet m/h 35.5 47.2 51.5 55.6 59.9
LT outlet temperature from engine at 36C inlet C 53 57 59 60 61
(1-string cooling water system)
Gas data:
Exhaust gas ow kg/h 6,920 10,200 11,900 13,600 15,300
Exhaust gas temperature at turbine outlet C 335 333 333 333 333
Maximum allowable back pressure bar 0.025 0.025 0.025 0.025 0.025
Air consumption kg/h 6,720 9,940 11,600 13,200 14,900
Starting air system:
Air consumption per start incl. air for jet assist Nm 1.0 1.2 1.4 1.6 1.8
Heat radiation:
Engine kW 21 47 50 54 56
Alternator kW ( See separate data from alternator maker )
The stated heat balances are based on 100% load and tropical
condition.
The mass ows and exhaust gas temperature are based on ISO
ambient condition.
* The outlet temperature of the HT water is xed to 80C, and
44C for the LT water.
At different inlet temperature the ow will change accordingly.
Example: If the inlet temperature is 25C then the LT ow will
change to (44-36)/(44-25)*100 = 42% of the original ow.
The HT ow will not change.
17856 53-3.0
MAN Diesel 4.08
Page 1 of 3
MAN Diesel
198 42 078.5 MAN B&W S80MC/MC-C/ME-C, K80MC-C/ME-C, S70MC/MC-C/ME-C/ME-GI,
L70MC-C/ME-C, S65ME-C/ME-GI, S60MC/MC-C/ME-C/ME-GI/ME-B,
L60MC-C/ME-C, S50MC/MC-C/ME-C/ME-B, S46MC-C/ME-B, S42MC,
S40MC-C/ME-B, S35MC/MC-C/ME-B, L35MC, S26MC
178 34 537.1 P Free passage between the engines, width 600 mm and height 2,000 mm
Q Min. distance between engines: 2,250 mm
* Depending on alternator
** Weight includes a standard alternator, make A. van Kaick
All dimensions and masses are approximate and subject to change without prior notice.
Fig. 4.08.01: Power and outline of L23/30H
A
C
B
H
1,270
Q
1,600
P
L23/30H GenSet Data
Bore: 225 mm Stroke: 300 mm
Power layout
720 r/min 60 Hz 750 r/min 50 Hz 900 r/min 60 Hz
Eng. kW Gen. kW Eng. kW Gen. kW Eng. kW Gen. kW
5L23/30H 650 620 675 640
6L23/30H 780 740 810 770 960 910
7L23/30H 910 865 945 900 1,120 1,065
8L23/30H 1,040 990 1,080 1,025 1,280 1,215
178 23 067.0
No. of Cyls. A (mm) * B (mm) * C (mm) H (mm)
**Dry weight
GenSet (t)
5 (720 r/min) 3,369 2,155 5,524 2,383 18.0
5 (750 r/min) 3,369 2,155 5,524 2,383 18.0
6 (720 r/min) 3,738 2,265 6,004 2,383 19.7
6 (750 r/min) 3,738 2,265 6,004 2,383 19.7
6 (900 r/min) 3,738 2,265 6,004 2,815 21.0
7 (720 r/min) 4,109 2,395 6,504 2,815 21.4
7 (750 r/min) 4,109 2,395 6,504 2,815 21.4
7 (900 r/min) 4,109 2,395 6,504 2,815 22.8
8 (720 r/min) 4,475 2,480 6,959 2,815 23.5
8 (750 r/min) 4,475 2,480 6,959 2,815 23.5
8 (900 r/min) 4,475 2,340 6,815 2,815 24.5
MAN Diesel 4.08
Page 2 of 3
MAN Diesel
198 42 078.5 MAN B&W S80MC/MC-C/ME-C, K80MC-C/ME-C, S70MC/MC-C/ME-C/ME-GI,
L70MC-C/ME-C, S65ME-C/ME-GI, S60MC/MC-C/ME-C/ME-GI/ME-B,
L60MC-C/ME-C, S50MC/MC-C/ME-C/ME-B, S46MC-C/ME-B, S42MC,
S40MC-C/ME-B, S35MC/MC-C/ME-B, L35MC, S26MC
Fig. 4.08.02a: List of capacities for L23/30H, 720/750 rpm, IMO Tier I.
L23/30H GenSet Data
Cyl. 5 6 7 8
Max. continuous rating at 720/750 RPM kW 650/675 780/810 910/945 1,040/1,080
Engine-driven Pumps:
Fuel oil feed pump (5.5-7.5 bar) m
3
/h 1.0 1.0 1.0 1.0
L.T. cooling water pump (1-2.5 bar) m
3
/h 55 55 55 55
H.T. cooling water pump (1-2.5 bar) m
3
/h 36 36 36 36
Lub. oil main pump (3-5 bar) m
3
/h 16 16 20 20
Separate Pumps:
Diesel oil pump (4 bar at fuel oil inlet A1) m/h 0.46/0.48 0.55/0.57 0.64/0.67 0.73/0.76
Fuel oil supply pump *** (4 bar discharge pressure) m
3
/h 0.22/0.23 0.27/0.28 0.31/0.33 0.36/0.37
Fuel oil circulating pump (8 bar at fuel oil inlet A1) m/h 0.46/0.48 0.56/0.58 0.65/0.67 0.74/0.77
L.T. cooling water pump* (1-2.5 bar) m
3
/h 35 42 48 55
L.T. cooling water pump** (1-2.5 bar) m
3
/h 48 54 60 73
H.T. cooling water pump (1-2.5 bar) m
3
/h 20 24 28 32
Lub. oil stand-by pump (3-5 bar) m
3
/h 14.0 15.0 16.0 17.0
Cooling Capacities:
Lubricating Oil:
Heat dissipation kW 69 84 98 112
L.T. cooling water quantity* m
3
/h 5.3 6.4 7.5 8.5
L.T. cooling water quantity** m
3
/h 18 18 18 25
Lub. oil temp. inlet cooler C 67 67 67 67
L.T. cooling water temp. inlet cooler C 36 36 36 36
Charge Air:
Heat dissipation kW 251 299 348 395
L.T. cooling water quantity m
3
/h 30 36 42 48
L.T. cooling water inlet cooler C 36 36 36 36
Jacket Cooling:
Heat dissipation kW 182 219 257 294
H.T. cooling water quantity m
3
/h 20 24 28 32
H.T. cooling water temp. inlet cooler C 77 77 77 77
Gas Data:
Exhaust gas ow kg/h 5,510 6,620 7,720 8,820
Exhaust gas temp. C 310 310 310 310
Max. allowable back. press. bar 0.025 0.025 0.025 0.025
Air consumption kg/s 1.49 1.79 2.09 2.39
Starting Air System:
Air consumption per start Nm
3
2.0 2.0 2.0 2.0
Heat Radiation:
Engine kW 21 25 29 34
Generator kW (See separat data from generator maker)
The stated heat dissipation, capacities of gas and engine-driven pumps are given at 720 RPM. Heat dissipation gas and pump capaci-
ties at 750 RPM are 4% higher than stated. If L.T. cooling are sea water, the L.T. inlet is 32 C instead of 36C.
Based on tropical conditions, except for exhaust ow and air consumption which are based on ISO conditions.
* Only valid for engines equipped with internal basic cooling water system nos. 1 and 2.
** Only valid for engines equipped with combined coolers, internal basic cooling water system no. 3.
*** To compensate for built on pumps, ambient condition, caloric value and adequate circulations ow. The ISO fuel oil consumption is
multiplied by 1.45.
MAN Diesel 4.08
Page 3 of 3
MAN Diesel
198 42 078.5 MAN B&W S80MC/MC-C/ME-C, K80MC-C/ME-C, S70MC/MC-C/ME-C/ME-GI,
L70MC-C/ME-C, S65ME-C/ME-GI, S60MC/MC-C/ME-C/ME-GI/ME-B,
L60MC-C/ME-C, S50MC/MC-C/ME-C/ME-B, S46MC-C/ME-B, S42MC,
S40MC-C/ME-B, S35MC/MC-C/ME-B, L35MC, S26MC
Fig. 4.08.02b: List of capacities for L23/30H, 900 rpm, IMO Tier I.
L23/30H GenSet Data
Cyl. 6 7 8
Max. continuous rating at 900 RPM kW 960 1,120 1,280
Engine-driven Pumps:
Fuel oil feed pump (5.5-7.5 bar) m
3
/h 1.3 1.3 1.3
L.T. cooling water pump (1-2.5 bar) m
3
/h 69 69 69
H.T. cooling water pump (1-2.5 bar) m
3
/h 45 45 45
Lub. oil main pump (3.5-5 bar) m
3
/h 20 20 20
Separate Pumps:
Diesel oil pump (4 bar at fuel oil inlet A1) m/h 0.69 0.81 0.92
Fuel oil supply pump*** (4 bar discharge pressure) m
3
/h 0.34 0.40 0.45
Fuel oil circulating pump (8 bar at fuel oil inlet A1) m/h 0.70 0.82 0.94
L.T. cooling water pump* (1-2.5 bar) m
3
/h 52 61 70
L.T. cooling water pump** (1-2.5 bar) m
3
/h 63 71 85
H.T. cooling water pump (1-2.5 bar) m
3
/h 30 35 40
Lub. oil stand-by pump (3.5-5 bar) m
3
/h 17 18 19
Cooling Capacities:
Lubricating Oil:
Heat dissipation kW 117 137 158
L.T. cooling water quantity* m
3
/h 7.5 8.8 10.1
SW L.T. cooling water quantity** m
3
/h 18 18 25
Lub. oil temp. inlet cooler C 67 67 67
L.T. cooling water temp. inlet cooler C 36 36 36
Charge Air:
Heat dissipation kW 369 428 487
L.T. cooling water quantity m
3
/h 46 53 61
L.T. cooling water inlet cooler C 36 36 36
Jacket Cooling:
Heat dissipation kW 239 281 323
H.T. cooling water quantity m
3
/h 30 35 40
H.T. cooling water temp. inlet cooler C 77 77 77
Gas Data:
Exhaust gas ow kg/h 8,370 9,770 11,160
Exhaust gas temp. C 325 325 325
Max. allowable back. press. bar 0.025 0.025 0.025
Air consumption kg/s 2.25 2.62 3.00
Startiang Air System:
Air consumption per start Nm
3
2.0 2.0 2.0
Haeat Radiation:
Engine kW 32 37 42
Generator kW (See separat data from generator maker)
If L.T. cooling are sea water, the L.T. inlet is 32 C instead of 36 C.
Based on tropical conditions, except for exhaust ow and air consumption which are based on ISO conditions.
* Only valid for engines equipped with internal basic cooling water system nos. 1 and 2.
** Only valid for engines equipped with combined coolers, internal basic cooling water system no. 3.
*** To compensate for built on pumps, ambient condition, caloric value and adequate circulations ow. The ISO fuel oil consumption is
multiplied by 1.45.
MAN Diesel 4.09
Page 1 of 3
MAN Diesel
198 42 091.5 MAN B&W K98MC/MC-C/ME/ME-C, S90MC-C/ME-C, K90MC-C/ME/ME-C,
S80MC/MC-C/ME-C, K80MC-C/ME-C, S70MC/MC-C/ME-C/ME-GI,
L70MC-C/ME-C, S65ME-C/ME-GI, S60MC/MC-C/ME-C/ME-GI/ME-B,
L60MC-C/ME-C, S50MC/MC-C/ME-C/ME-B, S46ME-B, S40ME-B, S35ME-B
L27/38 GenSet Data
Bore: 270 mm Stroke: 380 mm
Power layout
720 r/min 60 Hz 750 r/min 50 Hz
720/750 r/min
(MGO/MDO)
60/50 Hz
(MGO/MDO)
Eng. kW Gen. kW Eng. kW Gen. kW Eng. kW Gen. kW
5L27/38 1,500 1,440 1,600 1,536 - -
6L27/38 1,980 1,900 1,980 1,900 2,100 2,016
7L27/38 2,310 2,218 2,310 2,218 2,450 2,352
8L27/38 2,640 2,534 2,640 2,534 2,800 2,688
9L27/38 2,970 2,851 2,970 2,851 3,150 3,054
178 23 079.0
No. of Cyls. A (mm) * B (mm) * C (mm) H (mm)
**Dry weight
GenSet (t)
5 (720 r/min) 4,346 2,486 6,832 3,628 42.3
5 (750 r/min) 4,346 2,486 6,832 3,628 42.3
6 (720 r/min) 4,791 2,766 7,557 3,712 45.8
6 (750 r/min) 4,791 2,766 7,557 3,712 46.1
7 (720 r/min) 5,236 2,766 8,002 3,712 52.1
7 (750 r/min) 5,236 2,766 8,002 3,712 52.1
8 (720 r/min) 5,681 2,986 8,667 3,899 56.3
8 (750 r/min) 5,681 2,986 8,667 3,899 58.3
9 (720 r/min) 6,126 2,986 9,112 3,899 63.9
9 (750 r/min) 6,126 2,986 9,112 3,899 63.9
Fig. 4.09.01: Power and outline of L27/38
P Free passage between the engines, width 600 mm and height 2,000 mm
Q Min. distance between engines: 2,900 mm (without gallery) and 3,100 mm (with gallery)
* Depending on alternator
** Weight includes a standard alternator
All dimensions and masses are approximate and subject to change without prior notice.
178 33 898.2
A
C
B
H
1,480
P
Q
1,770
1,285
MAN Diesel 4.09
Page 2 of 3
MAN Diesel
198 42 091.5 MAN B&W K98MC/MC-C/ME/ME-C, S90MC-C/ME-C, K90MC-C/ME/ME-C,
S80MC/MC-C/ME-C, K80MC-C/ME-C, S70MC/MC-C/ME-C/ME-GI,
L70MC-C/ME-C, S65ME-C/ME-GI, S60MC/MC-C/ME-C/ME-GI/ME-B,
L60MC-C/ME-C, S50MC/MC-C/ME-C/ME-B, S46ME-B, S40ME-B, S35ME-B
Fig. 4.09.02a: List of capacities for L27/38, 720 rpm, IMO Tier I. Tier II values available on request.
178 48 636.1
L27/38 GenSet Data
Cyl. 5 6 7 8 9
Max continues rating 720 RPM kW 1,500 1,980 2,310 2,640 2,970
Engine driven pumps:
LT cooling water pump (2.5 bar) m/h 58 58 58 58 58
HT cooling water pump (2.5 bar) m/h 58 58 58 58 58
Lubricating oil main pump (8 bar) m/h 64 64 92 92 92
Separate pumps:
Max. Delivery pressure of cooling water pumps bar 2.5 2.5 2.5 2.5 2.5
Diesel oil pump (5 bar at fuel oil inlet A1) m/h 1.02 1.33 1.55 1.77 2.00
Fuel oil Supply pump (4 bar at discharge pressure) m/h 0.50 0.66 0.76 0.87 0.98
Fuel oil circulating pump (8 bar at fuel oil inlet A1) m/h 1.03 1.35 1.57 1.80 2.02
Cooling capacity:
Lubricating oil kW 206 283 328 376 420
Charge air LT kW 144 392 436 473 504
Total LT system kW 350 675 764 849 924
Flow LT at 36C inlet and 44C outlet m/h 38 58 58 58 58
Jacket cooling kW 287 486 573 664 754
Charge air HT kW 390 558 640 722 802
Total HT system kW 677 1,044 1,213 1,386 1,556
Flow HT at 44Cinlet and 80C outlet m/h 16 22 27 32 38
Total from engine kW 1,027 1,719 1,977 2,235 2,480
LT ow at 36C inlet m/h 38 58 58 58 58
LT temp. Outlet engine C 59 58 61 64 68
(at 36C and 1 string cooling water system)
Gas Data:
Exhaust gas ow kg/h 10,476 15,000 17,400 19,900 22,400
Exhaust gas temp. C 330 295 295 295 295
Max. Allowable back press. bar 0,025 0,025 0,025 0,025 0,025
Air consumption kg/h 10,177 14,600 17,000 19,400 21,800
Starting Air System:
Air consumption per start Nm
3
2,5 2,9 3,3 3,8 4,3
Heat Radiation:
Engine kW 53 64 75 68 73
Alternator kW (see separate data from the alternator maker)
The stated heat balances are based on tropical conditions.
The exhaust gas data (exhaust gas ow, exhaust gas temp.
and air consumption). are based on ISO ambient condition.
* The outlet temperature of the HT water is xed to 80C, and
44C for the LT water
At different inlet temperature the ow will change accordingly.
Example: If the inlet temperature is 25C then the LT ow will
change to (46-36)/(46-25)*100 = 53% of the original ow.
The HT ow will not change.
MAN Diesel 4.09
Page 3 of 3
MAN Diesel
198 42 091.5 MAN B&W K98MC/MC-C/ME/ME-C, S90MC-C/ME-C, K90MC-C/ME/ME-C,
S80MC/MC-C/ME-C, K80MC-C/ME-C, S70MC/MC-C/ME-C/ME-GI,
L70MC-C/ME-C, S65ME-C/ME-GI, S60MC/MC-C/ME-C/ME-GI/ME-B,
L60MC-C/ME-C, S50MC/MC-C/ME-C/ME-B, S46ME-B, S40ME-B, S35ME-B
L27/38 GenSet Data
Fig. 4.09.02b: List of capacities for L27/38, 750 rpm, IMO Tier I. Tier II values available on request.
Cyl. 5 6 7 8 9
Max continues rating 750 RPM kW 1,600 1,980 2,310 2,640 2,970
Engine driven pumps:
LT cooling water pump 2.5 bar m/h 70 70 70 70 70
HT cooling water pump 2.5 bar m/h 70 70 70 70 70
Lubricating oil main pump 8 bar m/h 66 66 96 96 96
Separate pumps:
Max. Delivery pressure of cooling water pumps bar 2.5 2.5 2.5 2.5 2.5
Diesel oil pump (5 bar at fuel oil inlet A1) m/h 1.10 1.34 1.57 1.79 2.01
Fuel oil supply pump (4 bar discharge pressure) m/h 0.54 0.66 0.77 0.88 0.99
Fuel oil circulating pump (8 bar at fuel oil inlet A1) m/h 1.11 1.36 1.59 1.81 2.04
Cooling capacity:
Lubricating oil kW 217 283 328 376 420
Charge air LT kW 155 392 436 473 504
Total LT system kW 372 675 764 849 924
Flow LT at 36C inlet and 44C outlet m/h 40 70 70 70 70
Jacket cooling kW 402 486 573 664 754
Charge air HT kW 457 558 640 722 802
Total HT system kW 859 1,044 1,213 1,386 1,556
Flow HT at 44Cinlet and 80C outlet m/h 21 22 27 32 38
Total from engine kW 1,231 1,719 1,977 2,235 2,480
LT ow at 36C inlet m/h 40 70 70 70 70
LT temp. Outlet engine C 62 55 58 61 64
(at 36C and 1 string cooling water system)
Gas Data:
Exhaust gas ow kg/h 11,693 15,000 17,400 19,900 22,400
Exhaust gas temp. C 330 305 305 305 305
Max. Allowable back press. bar 0.025 0.025 0.025 0.025 0.025
Air consumption kg/h 11,662 14,600 17,000 19,400 21,800
Starting Air System:
Air consumption per start Nm
3
2.5 2.9 3.3 3.8 4.3
Heat Radiation:
Engine kW 54 64 75 68 73
Alternator kW (see separate data from the alternator maker)
178 48 636.1
The stated heat balances are based on tropical conditions.
The exhaust gas data (exhaust gas ow, exhaust gas temp.
and air consumption). are based on ISO ambient condition.
* The outlet temperature of the HT water is xed to 80C, and
44C for the LT water
At different inlet temperature the ow will change accordingly.
Example: If the inlet temperature is 25C then the LT ow will
change to (46-36)/(46-25)*100 = 53% of the original ow.
The HT ow will not change.
MAN Diesel 4.10
Page 1 of 2
MAN Diesel
198 42 101.5 MAN B&W K98MC/MC-C/ME/ME-C, S90MC-C/ME-C, K90MC-C/ME/ME-C,
S80MC/MC-C/ME-C, K80MC-C/ME-C, S70MC/MC-C/ME-C/ME-GI,
L70MC-C/ME-C, S65ME-C/ME-GI, S60MC/MC-C/ME-C/ME-GI/ME-B,
L60MC-C/ME-C, S50MC/MC-C/ME-C/ME-B, S46ME-B, S40ME-B, S35ME-B
L28/32H GenSet Data
Bore: 280 mm Stroke: 320 mm
Power layout
720 r/min 60 Hz 750 r/min 50 Hz
Eng. kW Gen. kW Eng. kW Gen. kW
5L28/32H 1,050 1,000 1,100 1,045
6L28/32H 1,260 1,200 1,320 1,255
7L28/32H 1,470 1,400 1,540 1,465
8L28/32H 1,680 1,600 1,760 1,670
9L28/32H 1,890 1,800 1,980 1,880
178 23 092.0
No. of Cyls. A (mm) * B (mm) * C (mm) H (mm)
**Dry weight
GenSet (t)
5 (720 r/min) 4,279 2,400 6,679 3,184 32.6
5 (750 r/min) 4,279 2,400 6,679 3,184 32.6
6 (720 r/min) 4,759 2,510 7,269 3,184 36.3
6 (750 r/min) 4,759 2,510 7,269 3,184 36.3
7 (720 r/min) 5,499 2,680 8,179 3,374 39.4
7 (750 r/min) 5,499 2,680 8,179 3,374 39.4
8 (720 r/min) 5,979 2,770 8,749 3,374 40.7
8 (750 r/min) 5,979 2,770 8,749 3,374 40.7
9 (720 r/min) 6,199 2,690 8,889 3,534 47.1
9 (750 r/min) 6,199 2,690 8,889 3,534 47.1
P Free passage between the engines, width 600 mm and height 2,000 mm
Q Min. distance between engines: 2,655 mm (without gallery) and 2,850 mm (with gallery)
* Depending on alternator
** Weight includes a standard alternator, make A. van Kaick
All dimensions and masses are approximate and subject to change without prior notice.
178 33 921.3
Fig. 4.10.01: Power and outline of L28/32H
A
C
B
H P
1,490
Q
1,800
1,126
MAN Diesel 4.10
Page 2 of 2
MAN Diesel
198 42 101.5 MAN B&W K98MC/MC-C/ME/ME-C, S90MC-C/ME-C, K90MC-C/ME/ME-C,
S80MC/MC-C/ME-C, K80MC-C/ME-C, S70MC/MC-C/ME-C/ME-GI,
L70MC-C/ME-C, S65ME-C/ME-GI, S60MC/MC-C/ME-C/ME-GI/ME-B,
L60MC-C/ME-C, S50MC/MC-C/ME-C/ME-B, S46ME-B, S40ME-B, S35ME-B
Fig. 4.10.02: List of capacities for L28/32H, IMO Tier I.
L28/32H GenSet Data
Cyl. 5 6 7 8 9
Max. continuous rating at
720/
750 RPM
kW
1,050/
1,100
1,260/
1,320
1,470/
1,540
1,680/
1,760
1,890/
1,980
Engine-driven Pumps:
Fuel oil feed pump (5.5-7.5 bar) m
3
/h 1.4 1.4 1.4 1.4 1.4
L.T. cooling water pump (1-2.5 bar) m
3
/h 45 60 75 75 75
H.T. cooling water pump (1-2.5 bar) m
3
/h 45 45 60 60 60
Lub. oil main pump (3-5 bar) m
3
/h 23 23 31 31 31
Separate Pumps:
Diesel oil Pump (4 bar at fuel oil inlet A1) m/h 0.73/0.77 0.88/0.92 1.02/1.08 1.17/1.23 1.32/1.38
Fuel oil supply pump *** (4 bar discharge pressure) m
3
/h 0.36/0.38 0.43/0.45 0.50/0.53 0.57/0.60 0.64/0.68
Fuel oil circulating pump (8 bar at fuel oil inlet A1) m/h 0.74/0.78 0.89/0.93 1.04/1.09 1.18/1.25 1.33/1.40
L.T. cooling water pump* (1-2.5 bar) m
3
/h 45 54 65 77 89
L.T. cooling water pump** (1-2.5 bar) m
3
/h 65 73 95 105 115
H.T. cooling water pump (1-2.5 bar) m
3
/h 37 45 50 55 60
Lub. oil stand-by pump (3-5 bar) m
3
/h 22 23 25 27 28
Cooling Capacities:
Lubricating Oil:
Heat dissipation kW 105 127 149 172 194
L.T. cooling water quantity* m
3
/h 7.8 9.4 11.0 12.7 14.4
SW L.T. cooling water quantity** m
3
/h 28 28 40 40 40
Lub. oil temp. inlet cooler C 67 67 67 67 67
L.T. cooling water temp. inlet cooler C 36 36 36 36 36
Charge Air:
Heat dissipation kW 393 467 541 614 687
L.T. cooling water quantity m
3
/h 37 45 55 65 75
L.T. cooling water inlet cooler C 36 36 36 36 36
Jacket Cooling:
Heat dissipation kW 264 320 375 432 489
H.T. cooling water quantity m
3
/h 37 45 50 55 60
H.T. cooling water temp. inlet cooler C 77 77 77 77 77
Gas Data:
Exhaust gas ow kg/h 9,260 11,110 12,970 14,820 16,670
Exhaust gas temp. C 305 305 305 305 305
Max. allowable back. press. bar 0.025 0.025 0.025 0.025 0.025
Air consumption kg/s 2.51 3.02 3.52 4.02 4.53
Starting Air System:
Air consumption per start Nm
3
2.5 2.5 2.5 2.5 2.5
Heat Radiation:
Engine kW 26 32 38 44 50
Generator kW (See separat data from generator maker)
The stated heat dissipation, capacities of gas and engine-driven pumps are given at 720 RPM. Heat dissipation gas and pump capaci-
ties at 750 RPM are 4% higher than stated. If L.T. cooling are sea water, the L.T. inlet is 32 C instead of 36C.
Based on tropical conditions, except for exhaust ow and air consumption which are based on ISO conditions.
* Only valid for engines equipped with internal basic cooling water system nos. 1 and 2.
** Only valid for engines equipped with combined coolers, internal basic cooling water system no. 3.
*** To compensate for built on pumps, ambient condition, caloric value and adequate circulations ow. The ISO fuel oil consumption
is multiplied by 1.45.
MAN Diesel 4.11
Page 1 of 2
MAN Diesel
198 42 113.2 MAN B&W K98MC/MC-C/ME/ME-C,
S90MC-C/ME-C, K90MC-C/ME/ME-C
L32/40 GenSet Data
Bore: 320 mm Stroke: 400 mm
Power layout
720 r/min 60 Hz 750 r/min 50 Hz
Eng. kW Gen. kW Eng. kW Gen. kW
6L32/40 3,000 2,895 3,000 2,895
7L32/40 3,500 3,380 3,500 3,380
8L32/40 4,000 3,860 4,000 3,860
9L32/40 4,500 4,345 4,500 4,345
178 23 102.0
A B
C
H
P
Q
2,360 2,584
1,527
P Free passage between the engines, width 600 mm and height 2,000 mm
Q Min. distance between engines: 2,835 mm (without gallery) and 3,220 mm (with gallery)
* Depending on alternator
** Weight includes an alternator, Type B16, Make Siemens
All dimensions and masses are approximate and subject to change without prior notice.
178 34 557.3
Fig. 4.11.01: Power and outline of 32/40
No of Cyls. A (mm) * B (mm) * C (mm) H (mm)
**Dry weight
GenSet (t)
6 (720 r/min) 6,340 3,415 9,755 4,510 75.0
6 (750 r/min) 6,340 3,415 9,755 4,510 75.0
7 (720 r/min) 6,870 3,415 10,285 4,510 79.0
7 (750 r/min) 6,870 3,415 10,285 4,510 79.0
8 (720 r/min) 7,400 3,635 11,035 4,780 87.0
8 (750 r/min) 7,400 3,635 11,035 4,780 87.0
9 (720 r/min) 7,930 3,635 11,565 4,780 91.0
9 (750 r/min) 7,930 3,635 11,565 4,780 91.0
MAN Diesel 4.11
Page 2 of 2
MAN Diesel
198 42 113.2 MAN B&W K98MC/MC-C/ME/ME-C,
S90MC-C/ME-C, K90MC-C/ME/ME-C
L32/40 GenSet Data
Fig. 4.11.02: List of capacities for L32/40, IMO Tier I.
178 23 11-4.0
The stated heat balances are based on 100% load and tropical condition.
The mass fows and exhaust gas temperature are based on ISO ambient
condition.
Pump capacities of engine-driven pumps at 750 RPM are 4% higher than
stated.
z = Flushing oil of automatic flter.
500 kW/cyl
Cyl. 6 7 8 9
Max continues rating at: 720 RPM kW 3,000 3,500 4,000 4,500
750 RPM kW 3,000 3,500 4,000 4,500
Engine driven pumps:
LT cooling water pump 4.5 bar m/h 70 70 140 140
HT cooling water pump 4.5 bar m/h 70 70 70 70
Lubricating oil main pump 8 bar m/h 115 115 135 135
Pre-lubrication oil pump 1.5 bar m/h 21 21 27 34
Separate pumps:
Diesel oil pump (4 bar at fuel oil inlet A1) m/h 1.99 2.32 2.65 2.98
Fuel oil supply pump (4 bar discarge pressure) m/h 0.97 1.14 1.30 1.46
Fuel oil circulating pump (8 bar at fuel oil inlet A1) m/h 2.01 2.35 2.68 3.02
Fuel nozzle pump 3 bar m/h 1,0 1,2 1,4 1,6
LT cooling water pump 3 bar m/h 57 70 74 85
HT cooling water pump 4.3 bar m/h 42 49 56 63
Cooling capacity:
LT charge air kW 379 442 517 581
Lubrication oil engine kW 456 532 608 684
Lub. Seperator heat kW 25 29 33 38
Total Lub. Oil heat kW 481 561 641 721
Total heat dissipated LT side incl. Heat from Lub. Seperator kW 860 1,003 1,158 1,303
LT ow at 36C inlet engine m/h 57 70 74 85
Lub. Oil m/h 100 + z 110 + z 120 + z 130 + z
HT charge air kW 774 871 1011 1105
Jacket cooling kW 436 508 581 654
Total heat from HT side kW 1210 1380 1592 1759
HT temp. Inlet engine C 60 60 60 61
HT ow at 85C outlet engine m/h 42 49 56 63
Nozzel cooling kW 12 14 16 18
Gas Data:
Air consumption kg/h 21,600 25,200 28,800 32,400
Exhaust gas ow kg/h 22,200 25,900 29,600 33,300
Exhaust gas temperature at turbine outlet C 336 336 336 336
Starting air system:
Air consumption per start incl. Air for jet assist Nm 2,4 2,5 3,6 3,7
Heat ratiation:

Engine kW 109 127 145 164
Alternator kW (See separate data from alternator maker)
MAN B&W
MAN Diesel
Installation Aspects

5
MAN B&W 5.01
Page 1 of 1
MAN Diesel
198 43 754.7 MAN B&W MC/MCC, ME/MEC/ME-CGI/ME-B engines
Space Requirements and Overhaul Heights
A special crane beam for dismantling the turbo-
charger must be tted. The lifting capacity of the
crane beam for dismantling the turbocharger is
stated in Section 5.03.
The overhaul tools for the engine are designed
to be used with a crane hook according to DIN
15400, June 1990, material class M and load ca-
pacity 1Am and dimensions of the single hook
type according to DIN 15401, part 1.
The total length of the engine at the crankshaft
level may vary depending on the equipment to
be tted on the fore end of the engine, such as
adjustable counterweights, tuning wheel, moment
compensators or PTO.
The latest version of most of the drawings of
this section is available for download at www.
mandieselturbo.com under Products Marine
Engines & Systems Low Speed Installation
Drawings. First choose engine series, then engine
type and select from the list of drawings available
for download.
Space Requirements for the Engine
The space requirements stated in Section 5.02
are valid for engines rated at nominal MCR (L
1
).
The additional space needed for engines
equipped with PTO is stated in Chapter 4.
If, during the project stage, the outer dimensions
of the turbocharger seem to cause problems, it
is possible, for the same number of cylinders, to
use turbochargers with smaller dimensions by
increasing the indicated number of turbochargers
by one, see Chapter 3.
Overhaul of Engine
The distances stated from the centre of the crank-
shaft to the crane hook are for the normal lifting
procedure and the reduced height lifting proce-
dure (involving tilting of main components). The
lifting capacity of a normal engine room crane can
be found in Fig. 5.04.01.
The area covered by the engine room crane shall
be wide enough to reach any heavy spare part re-
quired in the engine room.
A lower overhaul height is, however, available by
using the MAN B&W DoubleJib crane, built by
Danish Crane Building A/S, shown in Figs. 5.04.02
and 5.04.03.
Please note that the distance E in Fig. 5.02.01,
given for a doublejib crane is from the centre
of the crankshaft to the lower edge of the deck
beam.
MAN B&W 5.02
Page 1 of 2
MAN Diesel
MAN B&W K98ME7-TII 198 74 46-6.0
Space Requirement
Fig. 5.02.01a: Space requirement for the engine, turbocharger on exhaust side (4 59 122) 515 90 52-7.1.0
C
o
f
f
e
r
d
a
m
C
y
l
.

1
A
A
Free space
for maintenance
K L M
A
F G
E
P
I J
V

Deck beam
H
3
H
1
/
H
2
0
Tank top
Lub. oil tank
C
B
D
C
o
f
f
e
r
d
a
m
Cofferdam
N
Engine room crane
Minimum access conditions around the engine to be used for an escape route is 600 mm.
The dimensions are given in mm, and are for guidance only. If the dimensions cannot be fullled, please contact MAN Diesel or our
local representative.
MAN B&W 5.02
Page 2 of 2
MAN Diesel
MAN B&W K98ME7-TII 198 74 46-6.0
Fig. 5.02.01b: Space requirement for the engine
Cyl. No. 6 7 8 9 10 11 12 14
A 1,750 Cylinder distance
B 1,750 Distance from crankshaft centre line to foundation
C 4,426 4,466 4,606 4,686 4,741 4,811 4,881 5,021
The dimension includes a cofferdam of 600 mm and must full minimum height to tank top accord-
ing to classication rules
D*
8,910 8,910 8,910 8,910 8,910 8,910 8,910 8,910 MAN Diesel TCA
Dimensions according to turbocharger choice at nominal MCR 8,750 8,860 8,860 8,750 8,750 8,860 8,860 8,860 ABB TPL
8,870 8,845 8,845 8,870 8,845 8,845 8,870 8,845 Mitsubishi MET
E*
5,325 5,567 5,376 5,754 6,027 6,164 6,301 6,566 MAN Diesel TCA
Dimensions according to turbocharger choice at nominal MCR 5,163 5,664 5,905 5,592 5,865 6,261 6,398 6,663 ABB TPL
5,093 5,490 5,731 5,522 5,950 6,087 5,884 6,489 Mitsubishi MET
F 4,850 See drawing: Engine Top Bracing, if top bracing tted on camshaft side
G
6,398 6,398 6,398 6,398 6,398 6,398 6,398 6,398 MAN Diesel TCA
The required space to the engine room casing includes mechanical top
bracing
6,036 6,725 6,725 6,036 6,036 6,725 6,725 6,725 ABB TPL
6,105 6,535 6,535 6,105 6,535 6,535 6,535 6,535 Mitsubishi MET
H1* 13,375 Minimum overhaul height, normal lifting procedure
H2* 13,075 Minimum overhaul height, reduced height lifting procedure
H3* -
The minimum distance from crankshaft centre line to lower edge of deck beam, when using MAN
B&W Double Jib Crane
I 2,320 Length from crankshaft centre line to outer side bedplate
J 640 Space for tightening control of holding down bolts
K See text
K must be equal to or larger than the propeller shaft, if the propeller shaft is to be drawn into the
engine room
L* 13,311 15,061 18,024 20,601 21,771 22,941 25,051 29,051 Minimum length of a basic engine, without 2
nd
order moment compensators
M 800 Free space in front of engine
N 5,560 Distance between outer foundation girders
O 3,950 Minimum crane operation area
P See tekst See drawing: Crane beam for Turbocharger for overhaul of turbocharger
V 0, 15, 30, 45, 60, 75, 90 Maximum 30 when engine room has minimum headroom above the turbocharger
* The min. engine room crane height is ie. dependent on the choice of crane, see the actual heights H1, H2 or
H3.

The min. engine room height is dependent on H1, H2, H3 or E+D.
Max. length of engine see the engine outline drawing
Length of engine with PTO see corresponding space requirement
517 10 58-9.0.0
MAN B&W 5.02
Page 1 of 2
MAN Diesel
MAN B&W K98ME-C7-TII 198 74 43-0.0
Space Requirement
Fig. 5.02.01a: Space requirement for the engine, turbocharger on exhaust side (4 59 122) 515 90 52-7.1.0
C
o
f
f
e
r
d
a
m
C
y
l
.

1
A
A
Free space
for maintenance
K L M
A
F G
E
P
I J
V

Deck beam
H
3
H
1
/
H
2
0
Tank top
Lub. oil tank
C
B
D
C
o
f
f
e
r
d
a
m
Cofferdam
N
Engine room crane
Minimum access conditions around the engine to be used for an escape route is 600 mm.
The dimensions are given in mm, and are for guidance only. If the dimensions cannot be fullled, please contact MAN Diesel or our
local representative.
MAN B&W 5.02
Page 2 of 2
MAN Diesel
MAN B&W K98ME-C7-TII 198 74 43-0.0
Fig. 5.02.01b: Space requirement for the engine
Cyl. No. 6 7 8 9 10 11 12 14
A 1,750 Cylinder distance
B 1,750 Distance from crankshaft centre line to foundation
C 4,461 4,541 4,621 4,711 4,761 4,831 4,901 5,021
The dimension includes a cofferdam of 600 mm and must full minimum height to tank top accord-
ing to classication rules
D*
8,650 8,650 8,650 8,650 8,650 8,650 8,650 8,650 MAN Diesel TCA
Dimensions according to turbocharger choice at nominal MCR 8,490 8,490 8,600 8,490 8,490 8,600 8,600 8,490 ABB TPL
8,610 8,585 8,585 8,610 8,610 8,585 8,610 8,585 Mitsubishi MET
E*
5,125 5,367 5,608 5,554 5,691 5,964 6,101 6,216 MAN Diesel TCA
Dimensions according to turbocharger choice at nominal MCR 4,963 5,205 5,705 5,392 5,529 6,061 6,198 6,054 ABB TPL
4,893 5,290 5,531 5,322 5,459 5,887 5,684 6,139 Mitsubishi MET
F 4,850 See drawing: Engine Top Bracing, if top bracing tted on camshaft side
G
6,395 6,395 6,395 6,395 6,395 6,395 6,395 6,395 MAN Diesel TCA
The required space to the engine room casing includes mechanical top
bracing
6,035 6,035 6,725 6,035 6,035 6,725 6,725 6,035 ABB TPL
6,105 6,635 6,635 6,105 6,105 6,635 6,105 6,635 Mitsubishi MET
H1* 12,900 Minimum overhaul height, normal lifting procedure
H2* 12,575 Minimum overhaul height, reduced height lifting procedure
H3* -
The minimum distance from crankshaft centre line to lower edge of deck beam, when using MAN
B&W Double Jib Crane
I 2,185 Length from crankshaft centre line to outer side bedplate
J 640 Space for tightening control of holding down bolts
K See text
K must be equal to or larger than the propeller shaft, if the propeller shaft is to be drawn into the
engine room
L* 13,311 15,084 16,811 19,801 21,551 23,301 25,051 28,606 Minimum length of a basic engine, without 2
nd
order moment compensators
M 800 Free space in front of engine
N 5,240 Distance between outer foundation girders
O 3,950 Minimum crane operation area
P See tekst See drawing: Crane beam for Turbocharger for overhaul of turbocharger
V 0, 15, 30, 45, 60, 75, 90 Maximum 30 when engine room has minimum headroom above the turbocharger
* The min. engine room crane height is ie. dependent on the choice of crane, see the actual heights H1, H2 or
H3.

The min. engine room height is dependent on H1, H2, H3 or E+D.
Max. length of engine see the engine outline drawing
Length of engine with PTO see corresponding space requirement
517 13 87-2.0.0
MAN B&W 5.02
Page 1 of 2
MAN Diesel
MAN B&W S90ME-C8-TII 198 74 41-7.0
Space Requirement
Fig. 5.02.01a: Space requirement for the engine, turbocharger on exhaust side (4 59 122) 515 90 52-7.1.0
C
o
f
f
e
r
d
a
m
C
y
l
.

1
A
A
Free space
for maintenance
K L M
A
F G
E
P
I J
V

Deck beam
H
3
H
1
/
H
2
0
Tank top
Lub. oil tank
C
B
D
C
o
f
f
e
r
d
a
m
Cofferdam
N
Engine room crane
Minimum access conditions around the engine to be used for an escape route is 600 mm.
The dimensions are given in mm, and are for guidance only. If the dimensions cannot be fullled, please contact MAN Diesel or our
local representative.
MAN B&W 5.02
Page 2 of 2
MAN Diesel
MAN B&W S90ME-C8-TII 198 74 41-7.0
Fig. 5.02.01b: Space requirement for the engine
* The min. engine room crane height is ie. dependent on the choice of crane, see the actual heights H1, H2 or
H3.

The min. engine room height is dependent on H1, H2, H3 or E+D.
Max. length of engine see the engine outline drawing
Length of engine with PTO see corresponding space requirement
516 32 28-6.1.0
Cyl. No. 5 6 7 8
A 1,602 Cylinder distance
B 1,850 Distance from crankshaft centre line to foundation
C 4,630 4,680 4,745 4,825
The dimension includes a cofferdam of 600 mm and must full minimum
height to tank top according to classication rules
D*
8,870 8,733 8,733 8,733 MAN Diesel TCA
Dimensions according to turbocharger choice at nomi-
nal MCR
8,710 8,710 8,710 - ABB TPL
8,652 8,652 8,652 8,788 Mitsubishi MET
E*
4,605 5,125 5,367 5,487 MAN Diesel TCA
Dimensions according to turbocharger choice at nomi-
nal MCR
4,617 4,963 5,205 5,584 ABB TPL
4,547 4,893 5,135 5,410 Mitsubishi MET
F 4,700 See drawing: Engine Top Bracing, if top bracing tted on camshaft side
G
- - - - MAN Diesel TCA
The required space to the engine room casing includes
mechanical top bracing
5,870 5,870 5,870 - ABB TPL
5,990 5,990 5,990 - Mitsubishi MET
H1* 14,500 Minimum overhaul height, normal lifting procedure
H2* 13,650 Minimum overhaul height, reduced height lifting procedure
H3* 14,100
The minimum distance from crankshaft centre line to lower edge of deck
beam, when using MAN B&W Double Jib Crane
I 2,500 Length from crankshaft centre line to outer side bedplate
J 640 Space for tightening control of holding down bolts
K See text
K must be equal to or larger than the propeller shaft, if the propeller shaft is
to be drawn into the engine room
L* 13,138 14,740 16,342 18,046 Minimum length of a basic engine, without 2
nd
order moment compensators
M 800 Free space in front of engine
N 5,838 Distance between outer foundation girders
O 3,600 Minimum crane operation area
P See tekst See drawing: Crane beam for Turbocharger for overhaul of turbocharger
V 0, 15, 30, 45, 60, 75, 90
Maximum 30 when engine room has minimum headroom above the turbo-
charger
MAN B&W 5.02
Page 1 of 2
MAN Diesel
MAN B&W S80ME-C9-TII 198 74 33-4.0
Space Requirement
Fig. 5.02.01a: Space requirement for the engine, turbocharger on exhaust side (4 59 122) 515 90 52-7.1.0
C
o
f
f
e
r
d
a
m
C
y
l
.

1
A
A
Free space
for maintenance
K L M
A
F G
E
P
I J
V

Deck beam
H
3
H
1
/
H
2
0
Tank top
Lub. oil tank
C
B
D
C
o
f
f
e
r
d
a
m
Cofferdam
N
Engine room crane
Minimum access conditions around the engine to be used for an escape route is 600 mm.
The dimensions are given in mm, and are for guidance only. If the dimensions cannot be fullled, please contact MAN Diesel or our
local representative.
MAN B&W 5.02
Page 2 of 2
MAN Diesel
MAN B&W S80ME-C9-TII 198 74 33-4.0
Fig. 5.02.01b: Space requirement for the engine
Cyl. No. 5 6 7 8
A 1,060 Cylinder distance
B 1,940 Distance from crankshaft centre line to foundation
C 3,965 4,010 4,095 4,150
The dimension includes a cofferdam of 600 mm and must full minimum
height to tank top according to classication rules
D*
- - - - MAN Diesel TCA
Dimensions according to turbocharger choice at nomi-
nal MCR
- - - - ABB TPL
- - - - Mitsubishi MET
E*
5,166 4,605 5,125 5,246 MAN Diesel TCA
Dimensions according to turbocharger choice at nomi-
nal MCR
5,263 4,617 4,963 4,084 ABB TPL
4,122 4,489 4,893 4,014 Mitsubishi MET
F - See drawing: Engine Top Bracing, if top bracing tted on camshaft side
G
- - - - MAN Diesel TCA
The required space to the engine room casing includes
mechanical top bracing
- - - - ABB TPL
5,780 - - - Mitsubishi MET
H1* 15,050 Minimum overhaul height, normal lifting procedure
H2* 13,925 Minimum overhaul height, reduced height lifting procedure
H3* 13,500
The minimum distance from crankshaft centre line to lower edge of deck
beam, when using MAN B&W Double Jib Crane
I 2,590 Length from crankshaft centre line to outer side bedplate
J 510 Space for tightening control of holding down bolts
K See text
K must be equal to or larger than the propeller shaft, if the propeller shaft is
to be drawn into the engine room
L* 10,700 12,034 13,368 16,002 Minimum length of a basic engine, without 2
nd
order moment compensators
M 800 Free space in front of engine
N 5,840 Distance between outer foundation girders
O - Minimum crane operation area
P See tekst See drawing: Crane beam for Turbocharger for overhaul of turbocharger
V 0, 15, 30, 45, 60, 75, 90
Maximum 30 when engine room has minimum headroom above the turbo-
charger
* The min. engine room crane height is ie. dependent on the choice of crane, see the actual heights H1, H2 or
H3.

The min. engine room height is dependent on H1, H2, H3 or E+D.
Max. length of engine see the engine outline drawing
Length of engine with PTO see corresponding space requirement
517 64 61-7.0.0
MAN B&W 5.02
Page 1 of 2
MAN Diesel
MAN B&W S80ME-C8-TII 198 74 39-5.0
Space Requirement
Fig. 5.02.01a: Space requirement for the engine, turbocharger on exhaust side (4 59 122) 515 90 52-7.1.0
C
o
f
f
e
r
d
a
m
C
y
l
.

1
A
A
Free space
for maintenance
K L M
A
F G
E
P
I J
V

Deck beam
H
3
H
1
/
H
2
0
Tank top
Lub. oil tank
C
B
D
C
o
f
f
e
r
d
a
m
Cofferdam
N
Engine room crane
Minimum access conditions around the engine to be used for an escape route is 600 mm.
The dimensions are given in mm, and are for guidance only. If the dimensions cannot be fullled, please contact MAN Diesel or our
local representative.
MAN B&W 5.02
Page 2 of 2
MAN Diesel
MAN B&W S80ME-C8-TII 198 74 39-5.0
Fig. 5.02.01b: Space requirement for the engine
Cyl. No. 5 6 7
A 1,424 Cylinder distance
B 1,786 Distance from crankshaft centre line to foundation
C 4,601 4,641 4,721
The dimension includes a cofferdam of 600 mm and must full minimum
height to tank top according to classication rules
D*
8,723 8,720 8,720 MAN Diesel TCA
Dimensions according to turbocharger choice at
nominal MCR
- 8,675 8,780 ABB TPL
8,778 8,740 8,681 Mitsubishi MET
E*
5,066 4,484 4,830 MAN Diesel TCA
Dimensions according to turbocharger choice at
nominal MCR
5,163 4,324 4,842 ABB TPL
4,989 4,368 4,775 Mitsubishi MET
F 4,100 See drawing: Engine Top Bracing, if top bracing tted on camshaft side
G
- - - MAN Diesel TCA
The required space to the engine room casing includes
mechanical top bracing
- - - ABB TPL
- - - Mitsubishi MET
H1* 14,325 Minimum overhaul height, normal lifting procedure
H2* 13,175 Minimum overhaul height, reduced height lifting procedure
H3* 12,950
The minimum distance from crankshaft centre line to lower edge of deck
beam, when using MAN B&W Double Jib Crane
I 2,500 Length from crankshaft centre line to outer side bedplate
J 510 Space for tightening control of holding down bolts
K See text
K must be equal to or larger than the propeller shaft, if the propeller shaft is
to be drawn into the engine room
L* 11,229 12,653 14,077 Minimum length of a basic engine, without 2
nd
order moment compensators
M 800 Free space in front of engine
N 5,710 Distance between outer foundation girders
O 3,200 Minimum crane operation area
P See tekst See drawing: Crane beam for Turbocharger for overhaul of turbocharger
V 0, 15, 30, 45, 60, 75, 90
Maximum 30 when engine room has minimum headroom above the turbo-
charger
* The min. engine room crane height is ie. dependent on the choice of crane, see the actual heights H1, H2 or
H3.

The min. engine room height is dependent on H1, H2, H3 or E+D.
Max. length of engine see the engine outline drawing
Length of engine with PTO see corresponding space requirement
517 52 68-4.0.0
MAN B&W 5.02
Page 1 of 2
MAN Diesel
MAN B&W K80ME-C9 198 79 03-2.0
Space Requirement
Fig. 5.02.01a: Space requirement for the engine, turbocharger on exhaust side (4 59 122) 515 90 52-7.1.0
C
o
f
f
e
r
d
a
m
C
y
l
.

1
A
A
Free space
for maintenance
K L M
A
F G
E
P
I J
V

Deck beam
H
3
H
1
/
H
2
0
Tank top
Lub. oil tank
C
B
D
C
o
f
f
e
r
d
a
m
Cofferdam
N
Engine room crane
Minimum access conditions around the engine to be used for an escape route is 600 mm.
The dimensions are given in mm, and are for guidance only. If the dimensions cannot be fullled, please contact MAN Diesel or our
local representative.
MAN B&W 5.02
Page 2 of 2
MAN Diesel
MAN B&W K80ME-C9 198 79 03-2.0
Fig. 5.02.01b: Space requirement for the engine
Cyl. No. 6 7 8 9 10 11 12
A 1,334 Cylinder distance
B 1,640 Distance from crankshaft centre line to foundation
C 4,145 4,190 4,265 4,575 4,445 4,500 4,575
The dimension includes a cofferdam of 600 mm and must full minimum
height to tank top according to classication rules
D*
- - 7,890 7,890 7,890 7,890 7,890 MAN Diesel TCA
Dimensions according to turbocharger choice at nominal
MCR
7,690 7,690 - - - - - ABB TPL
- 7,850 7,850 7,850 - - 7,850 Mitsubishi MET
E*
4,363 4,605 5,125 5,246 5,487 5,608 5,554 MAN Diesel TCA
Dimensions according to turbocharger choice at nominal
MCR
4,203 4,445 4,963 5,084 5,325 5,705 5,392 ABB TPL
4,247 4,547 4,893 5,014 5,410 5,531 5,322 Mitsubishi MET
F - See drawing: Engine Top Bracing, if top bracing tted on camshaft side
G
- - - - - - - MAN Diesel TCA
The required space to the engine room casing includes
mechanical top bracing
- - - - - - - ABB TPL
- - - - - - - Mitsubishi MET
H1* 12,400 Minimum overhaul height, normal lifting procedure
H2* 11,825 Minimum overhaul height, reduced height lifting procedure
H3* 11,675
The minimum distance from crankshaft centre line to lower edge of deck
beam, when using MAN B&W Double Jib Crane
I 2,200 Length from crankshaft centre line to outer side bedplate
J 510 Space for tightening control of holding down bolts
K See tekst
K must be equal to or larger than the propeller shaft, if the propeller shaft is to
be drawn into the engine room
L* 10,700 12,034 13,368 16,002 17,336 18,670 20,004 Minimum length of a basic engine, without 2
nd
order moment compensators
M 800 Free space in front of engine
N 5,110 Distance between outer foundation girders
O 3,025 Minimum crane operation area
P See tekst See drawing: Crane beam for Turbocharger for overhaul of turbocharger
V 0, 15, 30, 45, 60, 75, 90
Maximum 30 when engine room has minimum headroom above the turbo-
charger
* The min. engine room crane height is ie. dependent on the choice of crane, see the actual heights H1, H2 or
H3.

The min. engine room height is dependent on H1, H2, H3 or E+D.
Max. length of engine see the engine outline drawing
Length of engine with PTO see corresponding space requirement
520 18 92-4.0.0
MAN B&W 5.02
Page 1 of 2
MAN Diesel
MAN B&W K80ME-C6-TII 198 74 37-1.0
Space Requirement
Fig. 5.02.01a: Space requirement for the engine, turbocharger on exhaust side (4 59 122) 515 90 52-7.1.0
C
o
f
f
e
r
d
a
m
C
y
l
.

1
A
A
Free space
for maintenance
K L M
A
F G
E
P
I J
V

Deck beam
H
3
H
1
/
H
2
0
Tank top
Lub. oil tank
C
B
D
C
o
f
f
e
r
d
a
m
Cofferdam
N
Engine room crane
Minimum access conditions around the engine to be used for an escape route is 600 mm.
The dimensions are given in mm, and are for guidance only. If the dimensions cannot be fullled, please contact MAN Diesel or our
local representative.
MAN B&W 5.02
Page 2 of 2
MAN Diesel
MAN B&W K80ME-C6-TII 198 74 37-1.0
Fig. 5.02.01b: Space requirement for the engine
Cyl. No. 6 7 8 9 10 11 12
A 1,424 Cylinder distance
B 1,560 Distance from crankshaft centre line to foundation
C 4,000 4,060 4,145 4,225 4,275 4,325 4,380
The dimension includes a cofferdam of 600 mm and must full minimum
height to tank top according to classication rules
D*
- - 8,000 - - - - MAN Diesel TCA
Dimensions according to turbocharger choice at nominal
MCR
- - 7,680 7,680 7,680 7,680 - ABB TPL
- - 7,720 7,758 7,758 7,758 - Mitsubishi MET
E*
4,766 5,066 4,484 5,004 5,125 5,246 5,367 MAN Diesel TCA
Dimensions according to turbocharger choice at nominal
MCR
4,863 5,163 4,496 4,842 4,963 5,084 5,464 ABB TPL
4,689 4,002 4,368 4,772 4,893 4,014 5,290 Mitsubishi MET
F 4,500 See drawing: Engine Top Bracing, if top bracing tted on camshaft side
G
- - - - - - - MAN Diesel TCA
The required space to the engine room casing includes
mechanical top bracing
- - - - - - - ABB TPL
- - - - - - - Mitsubishi MET
H1* 11,625 Minimum overhaul height, normal lifting procedure
H2* 11,375 Minimum overhaul height, reduced height lifting procedure
H3* 11,275
The minimum distance from crankshaft centre line to lower edge of deck
beam, when using MAN B&W Double Jib Crane
I 2,044 Length from crankshaft centre line to outer side bedplate
J 510 Space for tightening control of holding down bolts
K See text
K must be equal to or larger than the propeller shaft, if the propeller shaft is to
be drawn into the engine room
L* 10,864 12,288 13,712 15,136 17,800 19,224 20,648 Minimum length of a basic engine, without 2
nd
order moment compensators
M 800 Free space in front of engine
N 5,220 Distance between outer foundation girders
O 3,200 Minimum crane operation area
P See tekst See drawing: Crane beam for Turbocharger for overhaul of turbocharger
V 0, 15, 30, 45, 60, 75, 90
Maximum 30 when engine room has minimum headroom above the turbo-
charger
* The min. engine room crane height is ie. dependent on the choice of crane, see the actual heights H1, H2 or
H3.

The min. engine room height is dependent on H1, H2, H3 or E+D.
Max. length of engine see the engine outline drawing
Length of engine with PTO see corresponding space requirement
517 53 98-9.0.0
MAN B&W 5.02
Page 1 of 2
MAN Diesel
MAN B&W S70ME-C8, S70ME-C8-GI-TII 198 74 35-8.0
Space Requirement
Fig. 5.02.01a: Space requirement for the engine, turbocharger on exhaust side (4 59 122) 515 90 52-7.1.0
C
o
f
f
e
r
d
a
m
C
y
l
.

1
A
A
Free space
for maintenance
K L M
A
F G
E
P
I J
V

Deck beam
H
3
H
1
/
H
2
0
Tank top
Lub. oil tank
C
B
D
C
o
f
f
e
r
d
a
m
Cofferdam
N
Engine room crane
Minimum access conditions around the engine to be used for an escape route is 600 mm.
The dimensions are given in mm, and are for guidance only. If the dimensions cannot be fullled, please contact MAN Diesel or our
local representative.
MAN B&W 5.02
Page 2 of 2
MAN Diesel
MAN B&W S70ME-C8, S70ME-C8-GI-TII 198 74 35-8.0
Fig. 5.02.01b: Space requirement for the engine
Cyl. No. 5 6 7 8
A 1,190 Cylinder distance
B 805 Distance from crankshaft centre line to foundation
C 4,072 4,162 4,202 4,267
The dimension includes a cofferdam of 600 mm and must full minimum
height to tank top according to classication rules
D*
8,010 8,010 8,010 8,010 MAN Diesel TCA
Dimensions according to turbocharger choice at nomi-
nal MCR
7,850 7,850 - 7,671 ABB TPL
7,970 7,970 7,725 7,725 Mitsubishi MET
E*
4,087 4,566 4,766 5,066 MAN Diesel TCA
Dimensions according to turbocharger choice at nomi-
nal MCR
4,099 4,404 4,863 4,083 ABB TPL
4,029 4,334 3,881 4,002 Mitsubishi MET
F 3,700 See drawing: Engine Top Bracing, if top bracing tted on camshaft side
G
5,045 5,415 5,415 5,415 MAN Diesel TCA
The required space to the engine room casing includes
mechanical top bracing
5,415 5,415 - 4,925 ABB TPL
5,415 5,415 4,925 4,925 Mitsubishi MET
H1* 12,550 Minimum overhaul height, normal lifting procedure
H2* 11,675 Minimum overhaul height, reduced height lifting procedure
H3* 11,425
The minimum distance from crankshaft centre line to lower edge of deck
beam, when using MAN B&W Double Jib Crane
I 2,195 Length from crankshaft centre line to outer side bedplate
J 460 Space for tightening control of holding down bolts
K See text
K must be equal to or larger than the propeller shaft, if the propeller shaft is
to be drawn into the engine room
L* 8,308 9,498 10,688 11,878 Minimum length of a basic engine, without 2
nd
order moment compensators
M 800 Free space in front of engine
N 4,970 Distance between outer foundation girders
O 2,850 Minimum crane operation area
P See tekst See drawing: Crane beam for Turbocharger for overhaul of turbocharger
V 0, 15, 30, 45, 60, 75, 90
Maximum 30 when engine room has minimum headroom above the turbo-
charger
* The min. engine room crane height is ie. dependent on the choice of crane, see the actual heights H1, H2 or
H3.

The min. engine room height is dependent on H1, H2, H3 or E+D.
Max. length of engine see the engine outline drawing
Length of engine with PTO see corresponding space requirement
517 55 69-2.0.0
MAN B&W 5.02
Page 1 of 2
MAN Diesel
MAN B&W L70ME-C8-TII 198 74 32-2.0
Space Requirement
Fig. 5.02.01a: Space requirement for the engine, turbocharger on exhaust side (4 59 122) 515 90 52-7.1.0
C
o
f
f
e
r
d
a
m
C
y
l
.

1
A
A
Free space
for maintenance
K L M
A
F G
E
P
I J
V

Deck beam
H
3
H
1
/
H
2
0
Tank top
Lub. oil tank
C
B
D
C
o
f
f
e
r
d
a
m
Cofferdam
N
Engine room crane
Minimum access conditions around the engine to be used for an escape route is 600 mm.
The dimensions are given in mm, and are for guidance only. If the dimensions cannot be fullled, please contact MAN Diesel or our
local representative.
MAN B&W 5.02
Page 2 of 2
MAN Diesel
MAN B&W L70ME-C8-TII 198 74 32-2.0
Fig. 5.02.01b: Space requirement for the engine
Cyl. No. 5 6 7 8
A 1,190 Cylinder distance
B 1,312 Distance from crankshaft centre line to foundation
C 3,767 3,852 3,892 3,982
The dimension includes a cofferdam of 600 mm and must full minimum
height to tank top according to classication rules
D*
7,580 7,580 7,580 7,580 MAN Diesel TCA
Dimensions according to turbocharger choice at nomi-
nal MCR
7,420 7,420 - 7,241 ABB TPL
7,540 7,540 7,295 7,295 Mitsubishi MET
E*
4,292 4,666 4,866 5,166 MAN Diesel TCA
Dimensions according to turbocharger choice at nomi-
nal MCR
4,304 4,504 4,963 4,203 ABB TPL
4,234 4,434 4,002 4,122 Mitsubishi MET
F 3,700 See drawing: Engine Top Bracing, if top bracing tted on camshaft side
G
- - - - MAN Diesel TCA
The required space to the engine room casing includes
mechanical top bracing
- - - - ABB TPL
- - 4,925 4,925 Mitsubishi MET
H1* 11,250 Minimum overhaul height, normal lifting procedure
H2* 10,550 Minimum overhaul height, reduced height lifting procedure
H3* 10,575
The minimum distance from crankshaft centre line to lower edge of deck
beam, when using MAN B&W Double Jib Crane
I 1,990 Length from crankshaft centre line to outer side bedplate
J 460 Space for tightening control of holding down bolts
K See text
K must be equal to or larger than the propeller shaft, if the propeller shaft is
to be drawn into the engine room
L* 8,308 9,498 10,688 11,878 Minimum length of a basic engine, without 2
nd
order moment compensators
M 800 Free space in front of engine
N 4,932 Distance between outer foundation girders
O 2,400 Minimum crane operation area
P See tekst See drawing: Crane beam for Turbocharger for overhaul of turbocharger
V 0, 15, 30, 45, 60, 75, 90
Maximum 30 when engine room has minimum headroom above the turbo-
charger
* The min. engine room crane height is ie. dependent on the choice of crane, see the actual heights H1, H2 or
H3.

The min. engine room height is dependent on H1, H2, H3 or E+D.
Max. length of engine see the engine outline drawing
Length of engine with PTO see corresponding space requirement
517 64 62-9.0.0
MAN B&W 5.02
Page 1 of 2
MAN Diesel
MAN B&W S65ME-C/ME-GI8-TII 198 78 08-6.0
Space Requirement
Fig. 5.02.01a: Space requirement for the engine, turbocharger on exhaust side (4 59 122) 515 90 52-7.1.0
C
o
f
f
e
r
d
a
m
C
y
l
.

1
A
A
Free space
for maintenance
K L M
A
F G
E
P
I J
V

Deck beam
H
3
H
1
/
H
2
0
Tank top
Lub. oil tank
C
B
D
C
o
f
f
e
r
d
a
m
Cofferdam
N
Engine room crane
Minimum access conditions around the engine to be used for an escape route is 600 mm.
The dimensions are given in mm, and are for guidance only. If the dimensions cannot be fullled, please contact MAN Diesel or our
local representative.
MAN B&W 5.02
Page 2 of 2
MAN Diesel
MAN B&W S65ME-C/ME-GI8-TII 198 78 08-6.0
Fig. 5.02.01b: Space requirement for the engine
Cyl. No. 5 6 7 8
A 1,105 Cylinder distance
B 1,460 Distance from crankshaft centre line to foundation
C 3,957 4,037 4,092 4,157
The dimension includes a cofferdam of 600 mm and must full minimum
height to tank top according to classication rules
D*
7,635 7,635 7,635 7,635 MAN Diesel TCA
Dimensions according to turbocharger choice at nomi-
nal MCR
7,285 7,476 7,486 7,486 ABB TPL
7,350 7,595 7,595 7,595 Mitsubishi MET
E*
3,987 4,466 4,766 4,866 MAN Diesel TCA
Dimensions according to turbocharger choice at nomi-
nal MCR
3,827 4,304 4,604 4,704 ABB TPL
3,871 4,234 4,534 4,185 Mitsubishi MET
F 3,460 See drawing: Engine Top Bracing, if top bracing tted on camshaft side
G
- 5,545 5,545 5,545 MAN Diesel TCA
The required space to the engine room casing includes
mechanical top bracing
- - - - ABB TPL
- - - - Mitsubishi MET
H1* 11,950 Minimum overhaul height, normal lifting procedure
H2* 11,225 Minimum overhaul height, reduced height lifting procedure
H3* 11,025
The minimum distance from crankshaft centre line to lower edge of deck
beam, when using MAN B&W Double Jib Crane
I 2,062 Length from crankshaft centre line to outer side bedplate
J 460 Space for tightening control of holding down bolts
K See text
K must be equal to or larger than the propeller shaft, if the propeller shaft is
to be drawn into the engine room
L* 7,614 8,698 9,782 10,866 Minimum length of a basic engine, without 2
nd
order moment compensators
M 800 Free space in front of engine
N 4,692 Distance between outer foundation girders
O 2,160 Minimum crane operation area
P See text See drawing: Crane beam for Turbocharger for overhaul of turbocharger
V 0, 15, 30, 45, 60, 75, 90
Maximum 30 when engine room has minimum headroom above the turbo-
charger
* The min. engine room crane height is ie. dependent on the choice of crane, see the actual heights H1, H2 or
H3.

The min. engine room height is dependent on H1, H2, H3 or E+D.
Max. length of engine see the engine outline drawing
Length of engine with PTO see corresponding space requirement
517 71 34-1.0.0
MAN B&W 5.02
Page 1 of 2
MAN Diesel
MAN B&W S60ME-C8/ME-B8 198 74 29-9.0
Space Requirement
Fig. 5.02.01a: Space requirement for the engine, turbocharger on exhaust side (4 59 122) 515 90 52-7.1.0
C
o
f
f
e
r
d
a
m
C
y
l
.

1
A
A
Free space
for maintenance
K L M
A
F G
E
P
I J
V

Deck beam
H
3
H
1
/
H
2
0
Tank top
Lub. oil tank
C
B
D
C
o
f
f
e
r
d
a
m
Cofferdam
N
Engine room crane
Minimum access conditions around the engine to be used for an escape route is 600 mm.
The dimensions are given in mm, and are for guidance only. If the dimensions cannot be fullled, please contact MAN Diesel or our
local representative.
MAN B&W 5.02
Page 2 of 2
MAN Diesel
MAN B&W S60ME-C8/ME-B8 198 74 29-9.0
Fig. 5.02.01b: Space requirement for the engine
Cyl. No. 5 6 7 8
A 1,020 Cylinder distance
B 1,350 Distance from crankshaft centre line to foundation
C 3,705 3,780 3,820 3,890
The dimension includes a cofferdam of 600 mm and must full minimum
height to tank top according to classication rules
D*
6,695 7,045 7,045 7,045 MAN Diesel TCA
Dimensions according to turbocharger choice at nomi-
nal MCR
6,700 6,700 6,886 6,886 ABB TPL
6,760 6,760 7,005 7,005 Mitsubishi MET
E*
3,642 3,987 4,292 4,666 MAN Diesel TCA
Dimensions according to turbocharger choice at nomi-
nal MCR
3,627 3,827 4,304 4,504 ABB TPL
3,546 3,871 4,234 4,434 Mitsubishi MET
F 3,400 See drawing: Engine Top Bracing, if top bracing tted on camshaft side
G
4,535 4,850 4,850 5,137 MAN Diesel TCA
The required space to the engine room casing includes
mechanical top bracing
4,680 4,680 - - ABB TPL
4,590 4,590 5,100 5,100 Mitsubishi MET
H1* 10,750 Minimum overhaul height, normal lifting procedure
H2* 10,000 Minimum overhaul height, reduced height lifting procedure
H3* 9,725
The minimum distance from crankshaft centre line to lower edge of deck
beam, when using MAN B&W Double Jib Crane
I 1,885 Length from crankshaft centre line to outer side bedplate
J 345 Space for tightening control of holding down bolts
K See text
K must be equal to or larger than the propeller shaft, if the propeller shaft is
to be drawn into the engine room
L* 7,122 8,142 9,162 10,182 Minimum length of a basic engine, without 2
nd
order moment compensators
M 800 Free space in front of engine
N 4,410 Distance between outer foundation girders
O 2,600 Minimum crane operation area
P See tekst See drawing: Crane beam for Turbocharger for overhaul of turbocharger
V 0, 15, 30, 45, 60, 75, 90
Maximum 30 when engine room has minimum headroom above the turbo-
charger
* The min. engine room crane height is ie. dependent on the choice of crane, see the actual heights H1, H2 or
H3.

The min. engine room height is dependent on H1, H2, H3 or E+D.
Max. length of engine see the engine outline drawing
Length of engine with PTO see corresponding space requirement
517 69 69-9.0.0
MAN B&W 5.02
Page 1 of 2
MAN Diesel
MAN B&W L60ME-C8-TII 198 77 97-6.0
Space Requirement
Fig. 5.02.01a: Space requirement for the engine, turbocharger on exhaust side (4 59 122) 515 90 52-7.1.0
C
o
f
f
e
r
d
a
m
C
y
l
.

1
A
A
Free space
for maintenance
K L M
A
F G
E
P
I J
V

Deck beam
H
3
H
1
/
H
2
0
Tank top
Lub. oil tank
C
B
D
C
o
f
f
e
r
d
a
m
Cofferdam
N
Engine room crane
Minimum access conditions around the engine to be used for an escape route is 600 mm.
The dimensions are given in mm, and are for guidance only. If the dimensions cannot be fullled, please contact MAN Diesel or our
local representative.
MAN B&W 5.02
Page 2 of 2
MAN Diesel
MAN B&W L60ME-C8-TII 198 77 97-6.0
Fig. 5.02.01b: Space requirement for the engine
Cyl. No. 5 6 7 8 9
A 1,020 Cylinder distance
B 1,132 Distance from crankshaft centre line to foundation
C 3,437 3,537 3,562 3,632 3,632
The dimension includes a cofferdam of 600 mm and must full minimum height to
tank top according to classication rules
D*
6,327 - - - - MAN Diesel TCA
Dimensions according to turbocharger choice at nominal
MCR
- - - - - ABB TPL
6,297 6,392 - - - Mitsubishi MET
E*
3,642 3,987 4,292 4,566 4,766 MAN Diesel TCA
Dimensions according to turbocharger choice at nominal
MCR
3,627 3,827 4,304 4,404 4,604 ABB TPL
3,555 3,746 4,176 4,334 4,534 Mitsubishi MET
F - See drawing: Engine Top Bracing, if top bracing tted on camshaft side
G
4,580 - - - - MAN Diesel TCA
The required space to the engine room casing includes me-
chanical top bracing
- - - - - ABB TPL
- - - - - Mitsubishi MET
H1* 9,650 Minimum overhaul height, normal lifting procedure
H2* 9,125 Minimum overhaul height, reduced height lifting procedure
H3* 8,925
The minimum distance from crankshaft centre line to lower edge of deck beam,
when using MAN B&W Double Jib Crane
I 1,745 Length from crankshaft centre line to outer side bedplate
J 345 Space for tightening control of holding down bolts
K See text
K must be equal to or larger than the propeller shaft, if the propeller shaft is to be
drawn into the engine room
L* 7,251 8,271 9,162 10,182 11,202 Minimum length of a basic engine, without 2
nd
order moment compensators
M 800 Free space in front of engine
N 4,130 Distance between outer foundation girders
O 2,650 Minimum crane operation area
P See tekst See drawing: Crane beam for Turbocharger for overhaul of turbocharger
V 0, 15, 30, 45, 60, 75, 90 Maximum 30 when engine room has minimum headroom above the turbocharger
* The min. engine room crane height is ie. dependent on the choice of crane, see the actual heights H1, H2 or
H3.

The min. engine room height is dependent on H1, H2, H3 or E+D.
Max. length of engine see the engine outline drawing
Length of engine with PTO see corresponding space requirement
519 47 85-1.0.0
MAN B&W 5.02
Page 1 of 4
MAN Diesel
MAN B&W S50ME-C8-TII 198 73 62-6.0
Space Requirement
Fig. 5.02.01a: Space requirement for the engine, turbocharger on exhaust side (4 59 122) 515 90 52-7.1.0
C
o
f
f
e
r
d
a
m
C
y
l
.

1
A
A
Free space
for maintenance
K L M
A
F G
E
P
I J
V

Deck beam
H
3
H
1
/
H
2
0
Tank top
Lub. oil tank
C
B
D
C
o
f
f
e
r
d
a
m
Cofferdam
N
Engine room crane
Minimum access conditions around the engine to be used for an escape route is 600 mm.
The dimensions are given in mm, and are for guidance only. If the dimensions cannot be fullled, please contact MAN Diesel or our
local representative.
MAN B&W 5.02
Page 2 of 4
MAN Diesel
MAN B&W S50ME-C8-TII 198 73 62-6.0
Fig. 5.02.01b: Space requirement for the engine
Cyl. No. 5 6 7 8 9
A 850 Cylinder distance
B 1,135 Distance from crankshaft centre line to foundation
C 3,158 3,198 3,278 3,308 3,388
The dimension includes a cofferdam of 600 mm and must full minimum
height to tank top according to classication rules
D*
5,536 5,536 5,536 5,961 5,961 MAN Diesel TCA
Dimensions according to turbocharger choice at
nominal MCR
5,561 5,561 5,557 5,557 5,561 ABB TPL
5,650 5,482 5,571 5,571 - Mitsubishi MET
E*
3,242 3,342 3,642 3,887 3,987 MAN Diesel TCA
Dimensions according to turbocharger choice at
nominal MCR
3,121 3,321 3,627 3,727 3,268 ABB TPL
3,011 3,355 3,546 3,646 2,871 Mitsubishi MET
F 3,175 See drawing: Engine Top Bracing, if top bracing tted on camshaft side
G
4,310 4,310 4,310 4,580 4,580 MAN Diesel TCA
The required space to the engine room casing in-
cludes mechanical top bracing
4,310 4,310 4,580 4,580 4,310 ABB TPL
4,310 - 4,580 4,580 - Mitsubishi MET
H1* 9,000 Minimum overhaul height, normal lifting procedure
H2* 8,475 Minimum overhaul height, reduced height lifting procedure
H3* 8,250
The minimum distance from crankshaft centre line to lower edge of deck
beam, when using MAN B&W Double Jib Crane
I 1,575 Length from crankshaft centre line to outer side bedplate
J 350 Space for tightening control of holding down bolts
K See text
K must be equal to or larger than the propeller shaft, if the propeller shaft
is to be drawn into the engine room
L* 5,924 6,774 7,624 8,474 9,324 Minimum length of a basic engine, without 2
nd
order moment compensators
M 800 Free space in front of engine
N 3,816 Distance between outer foundation girders
O 2,150 Minimum crane operation area
P See text See drawing: Crane beam for Turbocharger for overhaul of turbocharger
V 0, 15, 30, 45, 60, 75, 90
Maximum 30 when engine room has minimum headroom above the tur-
bocharger
* The min. engine room crane height is ie. dependent on the choice of crane, see the actual heights H1, H2 or
H3.

The min. engine room height is dependent on H1, H2, H3 or E+D.
Max. length of engine see the engine outline drawing
Length of engine with PTO see corresponding space requirement
517 71 37-7.0.0
MAN B&W 5.02
Page 3 of 4
MAN Diesel
MAN B&W S50ME-C8-TII 198 73 62-6.0
Fig. 5.02.02a: Space requirement for the engine, turbocharger on aft end (4 59 124) 517 78 19-6.0.0
A
K
A
M L
E
Y
D
V

Q
Lub. oil tank
Tank top
Cofferdam
Deck beam
Engine room crane
C
N
B
I J
U T
R S
O
Z
F
H
1
/
H
2
H
3
G
Free space
for maintenance
A
Minimum access conditions around the engine to be used for an escape route is 600 mm.
The dimensions are given in mm, and are for guidance only. If the dimensions cannot be fullled, please contact MAN Diesel or our
local representative.
MAN B&W 5.02
Page 4 of 4
MAN Diesel
MAN B&W S50ME-C8-TII 198 73 62-6.0
Fig. 5.02.02b: Space requirement for the engine, turbocharger on aft end (4 59 124)
Cyl. No. 5 6 7 8 9
A 850 Cylinder distance
B 1,135 Distance from crankshaft centre line to foundation
C 3,158 3,198 3,278 3,308 3,388
The dimension includes a cofferdam of 600 mm and must full minimum height to
tank top according to classication rules
D*
6,375 6,375 6,375 6,490 6,490 MAN Diesel TCA
Dimensions according to turbocharger choice at nominal
MCR
6,372 6,372 6,490 6,490 - ABB TPL
- - - - - Mitsubishi MET
E*
3,617 3,892 4,167 4,450 4,587 MAN Diesel TCA
Dimensions according to turbocharger choice at nominal
MCR
3,496 3,771 4,152 4,290 - ABB TPL
3,386 3,805 4,071 4,209 4,471 Mitsubishi MET
F - See drawing: Engine Top Bracing, if top bracing tted on camshaft side
G 2,780
MAN Diesel TCA
The required space to the engine room casing includes me-
chanical top bracing
ABB TPL
Mitsubishi MET
H1* 9,000 Minimum overhaul height, normal lifting procedure
H2* 8,475 Minimum overhaul height, reduced height lifting procedure
H3* 8,250
The minimum distance from crankshaft centre line to lower edge of deck beam,
when using MAN B&W Double Jib Crane
I 1,575 Length from crankshaft centre line to outer side bedplate
J 350 Space for tightening control of holding down bolts
K See text
K must be equal to or larger than the propeller shaft, if the propeller shaft is to be
drawn into the engine room
L* 5,924 6,774 7,624 8,474 9,324 Minimum length of a basic engine, without 2
nd
order moment compensators
M 800 Free space in front of engine
N 3,816 Distance between outer foundation girders
O 2,150 Minimum crane operation area
P See text See drawing: Crane beam for Turbocharger for overhaul of turbocharger
Q
1,600 1,600 1,600 1,515 1,515 MAN Diesel TCA
Dimensions according to turbocharger choice at nominal
MCR
1,654 1,654 1,700 1,700 - ABB TPL
- - - - - Mitsubishi MET
R
See text
Required crane coverage area and hook travelling width for turbocharger mainte-
nance and overhaul to be supplied by turbocharger maker
S
T
U
V 0, 15, 30, 45, 60, 75, 90 Maximum 30 when engine room has minimum headroom above the turbocharger
Y 4,240 4,220 4,624 4,624 - Space for water mist catcher overhaul.
Z 3,500 Space for air cooler element overhaul.
* The min. engine room crane height is ie. dependent on the choice of crane, see the actual heights H1, H2 or
H3.

The min. engine room height is dependent on H1, H2, H3 or E+D.
Max. length of engine see the engine outline drawing
Length of engine with PTO see corresponding space requirement
517 78 54-2.0.0
MAN B&W 5.03
Page 1 of 4
MAN Diesel
MAN B&W 98-50 MC/MC-C/ME/ME-C/-GI/ME-B Engine Selection Guide 198 79 62-9.0
Crane beam for overhaul of turbocharger
For the overhaul of a turbocharger, a crane beam
with trolleys is required at each end of the turbo-
charger.
Two trolleys are to be available at the compressor
end and one trolley is needed at the gas inlet end.
Crane beam no. 1 is for dismantling of turbocharg-
er components.
Crane beam no. 2 is for transporting turbocharger
components.
See Figs. 5.03.01a and 5.03.02.
The crane beams can be omitted if the main engine
room crane also covers the turbocharger area.
The crane beams are used and dimensioned for
lifting the following components:
Exhaust gas inlet casing
Turbocharger inlet silencer
Compressor casing
Turbine rotor with bearings
The crane beams are to be placed in relation to the
turbocharger(s) so that the components around the
gas outlet casing can be removed in connection
with overhaul of the turbocharger(s).
The crane beam can be bolted to brackets that
are fastened to the ship structure or to columns
that are located on the top platform of the engine.
The lifting capacity of the crane beam for the
heaviest component W, is indicated in Fig.
5.03.01b for the various turbocharger makes. The
crane beam shall be dimensioned for lifting the
weight W with a deection of some 5 mm only.
HB indicates the position of the crane hook in the
vertical plane related to the centre of the turbo-
charger. HB and b also species the minimum
space for dismantling.
For engines with the turbocharger(s) located on
the exhaust side, EoD No. 4 59 122, the letter
a indicates the distance between vertical cen-
trelines of the engine and the turbocharger.
Mitsubishi
Units MET66 MET71 MET90
W kg 1,500 1,800 3,500
HB mm 1,800 1,800 2,200
b m 800 800 800
178 52 340.1
Fig. 5.03.01a: Required height and distance
Crane beam
Turbocharger
Gas outlet flange
a
H
B
M
a
i
n

e
n
g
i
n
e
/
a
f
t

c
y
l
i
n
d
e
rCrane hook
b
E
n
g
i
n
e

r
o
o
m

s
i
d
e
Crane beam for
dismantling of
components
Crane beam for
transportation of
components
Fig. 5.03.01b: Example of required height and distance
and weight based on S80ME-C and S80MC-C engines.
For data on other engines, please see section 5.03,
Fig. 5.03.01b of the specic engine Project Guide.
The gures a are stated on the Engine and Gallery Outline
drawing, Section 5.06.
MAN B&W
Units TCA77 TCA88
W kg 2,000 3,000
HB mm 1,800 2,000
b m 800 1,000
ABB
Units A180 A185
W kg
Available on
request
HB mm
b m
ABB
Units TPL80 TPL85 TPL91
W kg 1,500 3,000 4,500
HB mm 1,900 2,200 2,350
b m 800 1,000 1,100
MAN B&W 5.03
Page 2 of 4
MAN Diesel
MAN B&W 98-50 MC/MC-C/ME/ME-C/-GI/ME-B Engine Selection Guide 198 79 62-9.0
Crane beam for turbochargers
Crane beam for transportation of components
Crane beam for dismantling of components
Spares
Crane beam for transportation of components
Crane beam for dismantling of components
178 52 746.0
Fig. 5.03.02: Crane beam for turbocharger
MAN B&W 5.03
Page 3 of 4
MAN Diesel
MAN B&W 98-50 MC/MC-C/ME/ME-C/-GI/ME-B Engine Selection Guide 198 79 62-9.0
Crane beam for overhaul of air cooler
For 98-50 engines
Overhaul/exchange of scavenge air cooler.
Valid for air cooler design for the following engines
with more than one turbochargers mounted on the
exhaust side.
1. Dismantle all the pipes in the area around the
air cooler.
2. Dismantle all the pipes around the inlet cover
for the cooler.
3. Take out the cooler insert by using the above
placed crane beam mounted on the engine.
4. Turn the cooler insert to an upright position.
5. Dismantle the platforms below the air cooler.
Engine room crane
5
4
8
1 2 3
6
7
6. Lower down the cooler insert between the gal-
lery brackets and down to the engine room
oor.
Make sure that the cooler insert is supported,
e.g. on a wooden support.
7. Move the air cooler insert to an area covered
by the engine room crane using the lifting
beam mounted below the lower gallery of the
engine.
8. By using the engine room crane the air cooler
insert can be lifted out of the engine room.
178 52 734.0 Fig.: 5.03.03: Crane beam for overhaul of air cooler, turbochargers located on exhaust side of the engine
MAN B&W 5.03
Page 4 of 4
MAN Diesel
MAN B&W 98-50 MC/MC-C/ME/ME-C/-GI/ME-B Engine Selection Guide 198 79 62-9.0
Crane beam
for A/C
4 3
5
2 1
1 2 3 4
5
517 93 99-9.0.0 Fig.: 5.03.04: Crane beam for overhaul of air cooler, turbocharger located on aft end of the engine
Overhaul/exchange of scavenge air cooler.
The text and gures are for guidance only.
Valid for all engines with aft mounted Turbocharger.
1. Dismantle all the pipes in the area around the
air cooler.
2. Dismantle all the pipes around the inlet cover
for the cooler.
3. Take out the cooler insert by using the above
placed crane beam mounted on the engine.
4. Turn the cooler insert to an upright position.
5. By using the engine room crane the air cooler
insert can be lifted out of the engine room.
Crane beam for overhaul of air cooler
For 50 engines
MAN B&W 5.04
Page 1 of 3
MAN Diesel
MAN B&W 98-50 ME/ME-C Engine Selection Guide 198 48 307.3
Fig. 5.04.01: Engine room crane
Engine room crane
1) The lifting tools for the engine are designed to t together
with a standard crane hook with a lifting capacity in ac-
cordance with the gure stated in the table. If a larger
crane hook is used, it may not t directly to the overhaul
tools, and the use of an intermediate shackle or similar
between the lifting tool and the crane hook will affect the
requirements for the minimum lifting height in the engine
room (dimension H).
2) The hatched area shows the height where an MAN B&W
Double-Jib Crane has to be used.
The crane hook travelling area must cover at least
the full length of the engine and a width in accord-
ance with dimension A given on the drawing (see
cross-hatched area).
It is furthermore recommended that the engine
room crane can be used for transport of heavy
spare parts from the engine room hatch to the
spare part stores and to the engine.
See example on this drawing.
The crane hook should at least be able to reach
down to a level corresponding to the centre line of
the crankshaft.
For overhaul of the turbocharger(s), trolley mount-
ed chain hoists must be installed on a separate
crane beam or, alternatively, in combination with
the engine room crane structure, see separate
drawing with information about the required lifting
capacity for overhaul of turbochargers.



Normal crane
Crankshaft
Deck beam
A A
A
1
)
H
1
/
H
2
2)
Deck
Deck beam
H
3
D
Deck
Crankshaft
MAN B&W Doublejib Crane
Recommended area to be covered
by the engine room crane
Spares
Engine room hatch
Minimum area
to be covered
by the engine
room crane



Normal crane
Crankshaft
Deck beam
A A
A
1
)
H
1
/
H
2
2)
Deck
Deck beam
H
3
D
Deck
Crankshaft
MAN B&W Doublejib Crane
Recommended area to be covered
by the engine room crane
Spares
Engine room hatch
Minimum area
to be covered
by the engine
room crane
519 24 62-8.0.0
MAN B&W 5.04
Page 2 of 3
MAN Diesel
MAN B&W 98-50 ME/ME-C Engine Selection Guide 198 48 307.3
The crane hook travelling area must cover at least
the full length of the engine and a width in accor-
dance with dimension A given on the drawing, see
crosshatched area.
It is furthermore recommended that the engine
room crane can be used for transport of heavy
spare parts from the engine room hatch to the
spare part stores and to the engine. See example
on this drawing.
The crane hook should at least be able to reach
down to a level corresponding to the centre line of
the crankshaft.
For overhaul of the turbocharger(s), trolley mount-
ed chain hoists must be installed on a separate
crane beam or, alternatively, in combination with
the engine room crane structure, see Crane beam
for overhaul of turbochargers with information
about the required lifting capacity for overhaul of
turbocharger(s).
Table 5.04.02: Engine room crane data.
Mass in kg including
lifting tools
Crane capacity in
tons selected
in accordance with
DIN and JIS
standard capacities
Crane
operating
width
in mm
Normal Crane
Height to crane hook in
mm for:
MAN B&W Double-Jib Crane
Normal
lifting
procedure
Reduced
height lift-
ing
procedure
involving
tilting of
main com-
ponents
(option)
Building-in height
in mm
A H1 H2 H3 D
E
n
g
i
n
e

t
y
p
e
C
y
l
i
n
d
e
r

c
o
v
e
r
c
o
m
p
l
e
t
e

w
i
t
h
e
x
h
a
u
s
t

v
a
l
v
e
C
y
l
i
n
d
e
r

l
i
n
e
r

w
i
t
h

c
o
o
l
i
n
g

j
a
c
k
e
t
P
i
s
t
o
n

w
i
t
h

r
o
d

a
n
d
s
t
u
f

n
g

b
o
x
N
o
r
m
a
l

c
r
a
n
e
M
A
N

B
&
W

D
o
u
b
l
e

J
i
b

C
r
a
n
e
M
i
n
i
m
u
m

d
i
s
t
a
n
c
e
M
i
n
i
m
u
m

h
e
i
g
h
t

f
r
o
m

c
e
n
t
r
e

l
i
n
e

c
r
a
n
k
s
h
a
f
t

t
o

c
e
n
t
r
e

l
i
n
e

c
r
a
n
e

h
o
o
k
M
i
n
i
m
u
m

h
e
i
g
h
t

f
r
o
m

c
e
n
t
r
e

l
i
n
e

c
r
a
n
k
s
h
a
f
t

t
o

c
e
n
t
r
e

l
i
n
e

c
r
a
n
e

h
o
o
k
M
i
n
i
m
u
m

h
e
i
g
h
t

f
r
o
m

c
e
n
t
r
e

l
i
n
e

c
r
a
n
k
-
s
h
a
f
t

t
o

u
n
d
e
r
s
i
d
e

d
e
c
k

b
e
a
m
A
d
d
i
t
i
o
n
a
l

h
e
i
g
h
t

r
e
-
q
u
i
r
e
d

f
o
r

r
e
m
o
v
a
l

o
f

e
x
h
a
u
s
t

v
a
l
v
e

c
o
m
-
p
l
e
t
e
w
i
t
h
o
u
t

r
e
m
o
v
-
i
n
g

a
n
y

e
x
h
a
u
s
t

s
t
u
d
K98ME7 10,850 9,100 6,050 12.5 2x6.3 3,950 13,375 13,075 - -
K98ME-C7 10,700 7,825 9,550 12.5 2x6.3 3,950 12,900 12,575 - -
S90ME-C8 8,850 9,150 5,400 10.0 2x6.3 3,600 14,500 13,650 14,100 350
K90ME9
Available on request
K90ME-C9
S80ME-C9 6,725 9,750 3,725 10.0 2x5.0 - 15,050 13,925 13,500 725
S80ME-C8 6,200 8,350 4,125 10.0 2x5.0 3,250 14,325 13,175 12,950 675
K80ME-C6 6,525 4,800 3,675 8.0 2x4.0 3,500 11,625 11,375 11,225 725
K80ME-C9 6,175 6,300 3,700 8.0 2x4.0 3,025 12,400 11,825 11,675 750
S70ME-C8 5,525 5,625 2,550 6.3 2x3.0 2,850 12,550 11,675 11,425 575
L70ME-C8 4,250 4,550 2,350 5.0 2x2.5 2,850 11,250 10,550 10,575 650
S65ME-C8 3,275 4,425 2,200 5.0 2x2.5 2,850 11,950 11,225 11,025 450
S60ME-C8 2,950 3,425 1,650 4.0 2x2.0 2,650 10,750 10,000 9,725 150
L60ME-C8 2,575 2,775 1,550 3.2 2x2.0 2,650 9,650 9,125 8,925 575
S50ME-C8 1,725 1,900 975 2.0 2x1.6 2,150 9,000 8,475 8,250 425
MAN B&W 5.04
Page 3 of 3
MAN Diesel
MAN B&W 98-50 ME/ME-C Engine Selection Guide 198 48 307.3
The DoubleJib crane
is available from:
Danish Crane Building A/S
P.O. Box 54
sterlandsvej 2
DK9240 Nibe, Denmark
Telephone: + 45 98 35 31 33
Telefax: + 45 98 35 30 33
Email: dcb@dcb.dk
178 24 863.0
Fig. 5.04.03: Overhaul with DoubleJib crane
Overhaul with MAN B&W DoubleJib crane
Deck beam
MAN B&W Double-Jib Crane
Centreline crankshaft
MAN B&W 5.05
Page 1 of 1
MAN Diesel
198 47 31-3.3 MAN B&W MC/ME Engine Selection Guide
Engine Outline
Please note that the information is to be found in
section 1.03 and in the Project Guide for the rel-
evant engine type.
The latest version of the dimensioned drawing
is available for download at www.mandiesel-
turbo.com under Products Marine Engines &
Systems Low Speed Installation Drawings.
First choose engine series, then engine type and
select Outline drawing for the actual number of
cylinders and type of turbocharger installation in
the list of drawings available for download.
MAN B&W 5.06
Page 1 of 1
MAN Diesel
198 48 54-7.2 MAN B&W MC/ME Engine Selection Guide
Gallery Outline
Please note that the information is to be found in
the Project Guide for the relevant engine type.
The latest version of the dimensioned drawing
is available for download at www.mandiesel-
turbo.com under Products Marine Engines &
Systems Low Speed Installation Drawings.
First choose engine series, then engine type and
select Outline drawing for the actual number of
cylinders and type of turbocharger installation in
the list of drawings available for download.
MAN B&W 5.07
Page 1 of 1
MAN Diesel
198 48 32-0.1 MAN B&W MC/ME Engine Selection Guide
Centre of Gravity
Please note that the information is to be found in
the Project Guide for the relevant engine type.
MAN B&W 5.08
Page 1 of 1
MAN Diesel
198 48 31-9.1 MAN B&W MC/ME Engine Selection Guide
Water and Oil in Engine
Please note that the information is to be found in
the Project Guide for the relevant engine type.
MAN B&W 5.09
Page 1 of 1
MAN Diesel
198 48 33-2.1 MAN B&W MC/ME Engine Selection Guide
Engine Pipe Connections
Please note that the information is to be found in
the Project Guide for the relevant engine type.
MAN B&W 5.10
Page 1 of 1
MAN Diesel
198 48 34-4.1 MAN B&W MC/ME Engine Selection Guide
Counteranges
Please note that the information is to be found in
the Project Guide for the relevant engine type.
MAN B&W 5.11
Page 1 of 1
MAN Diesel
198 49 23-1.2 MAN B&W MC/ME Engine Selection Guide
Engine Seating and Holding Down Bolts
Please note that the latest version of most of the
drawings of this section is available for download
at www.mandieselturbo.com under Products
Marine Engines & Systems Low Speed
Installation Drawings. First choose engine series,
then engine type and select Engine seating in the
general section of the list of drawings available for
download.
Engine Seating and Arrangement of
Holding Down Bolts
The dimensions of the seating stated in Fig.
5.12.01 are for guidance only.
Further information is to be found in the Project
Guide for the relevant engine type.
MAN B&W 5.12
Page 1 of 1
MAN Diesel
MAN B&W 98-50 ME/ME-C Engine Selection Guide 198 39 166.5
Fig. 5.12.01: Prole of engine seating, epoxy chocks
178 06 434.3
Engine Seating Prole
If required by classification society,
apply this bracket.
Thickness of bracket is the same
as thickness of floorplates.
M
K
L
J
Centre line
crankshaft
C
e
n
t
r
e

l
i
n
e

e
n
g
i
n
e
I
H
F
D
B
A
N
E
P
G
Slots to be
cut in vertical
floor plates to
clear nuts
where necessary.
Thickness of
floorplates
between main
engine girders.
C
Continous girder
to extend with
full dimensions
Engine type A B C D E F G H I J K L M N P
K98ME7 3,255 2,730 50 1,955 60 1,525 50 1,510 30 781 1,700 80 50 500 38
K98MEC7 3,120 2,570 50 1,825 60 1,375 50 1,360 30 781 1,700 80 50 500 38
S90MEC8 3,360 2,875 44 2,100 55 1,755 44 1,730 30 920 1,800 75 50 470 34
K90ME9
Available om request
K90MEC9
S80MEC9 3,340 2,880 40 2,225 50 1,845 40 1,830 25 785 1,890 70 50 440 34
S80MEC8 3,275 2,815 40 2,100 50 1,735 40 1,710 25 920 1,736 70 50 440 34
K80MEC9 2,975 2,515 40 1,860 50 1,380 40 1,365 25 580 1,640 70 50 440 34
K80MEC6 2,890 2,570 40 1,950 50 1,340 40 1,315 25 677 1,510 70 50 430 34
S70MEC8 2,880 2,485 36 1,890 45 1,530 36 1,515 22 805 1,520 65 50 400 34
L70MEC 2,670 2,430 36 1,965 45 1,405 36 1,385 20 755 1,262 65 50 400 34
S65MEC8 2,695 2,310 36 1,755 45 1,420 36 1,405 22 800 1,410 60 50 370 34
S60MEC8 2,410 2,175 30 1,855 40 1,330 30 1,315 20 700 1,300 60 50 400 25
L60MEC8 2,270 2,035 30 1,690 40 1,215 30 1,200 20 640 1,082 60 50 400 25
S50MEC 2,090 1,880 28 1,505 36 1,110 28 1,095 20 518 1,088 50 47 400 22
Table 5.12.02: Engine seating data
Dimensions are stated in mm
MAN B&W MC/MCC, ME/MEC/MEGI/ME-B engines 198 46 725.8
MAN B&W 5.13
Page 1 of 2
MAN Diesel MAN Diesel
The so-called guide force moments are caused by
the transverse reaction forces acting on the cross-
heads due to the connecting rod and crankshaft
mechanism. When the piston of a cylinder is not
exactly in its top or bottom position the gas force
from the combustion, transferred through the con-
necting rod, will have a component acting on the
crosshead and the crankshaft perpendicularly to
the axis of the cylinder. Its resultant is acting on
the guide shoe and together they form a guide
force moment.
The moments may excite engine vibrations mov-
ing the engine top athwart ships and causing a
rocking (excited by H-moment) or twisting (excited
by X-moment) movement of the engine. For en-
gines with less than seven cylinders, this guide
force moment tends to rock the engine in the
transverse direction, and for engines with seven
cylinders or more, it tends to twist the engine.
The guide force moments are harmless to the
engine except when resonance vibrations occur
in the engine/double bottom system. They may,
however, cause annoying vibrations in the super-
structure and/or engine room, if proper counter-
measures are not taken.
As a detailed calculation of this system is normally
not available, MAN Diesel recommends that top
bracing is installed between the engines upper
platform brackets and the casing side.
However, the top bracing is not needed in all
cases. In some cases the vibration level is lower if
the top bracing is not installed. This has normally
to be checked by measurements, i.e. with and
without top bracing.
If a vibration measurement in the rst vessel of a
series shows that the vibration level is acceptable
without the top bracing, we have no objection to
the top bracing being removed and the rest of
the series produced without top bracing. It is our
experience that especially the 7-cylinder engine
will often have a lower vibration level without top
bracing.
Without top bracing, the natural frequency of
the vibrating system comprising engine, ships
bottom, and ships side is often so low that reso-
nance with the excitation source (the guide force
moment) can occur close to the normal speed
range, resulting in the risk of vibration.
With top bracing, such a resonance will occur
above the normal speed range, as the natural fre-
quencies of the double bottom/main engine sys-
tem will increase. The impact of vibration is thus
lowered.
The top bracing is normally installed on the ex-
haust side of the engine, but can alternatively be
installed on the manoeuvring side. A combination
of exhaust side and manoeuvring side installation
is also possible.
The top bracing system is installed either as a
mechanical top bracing or a hydraulic top bracing.
Both systems are described below.
Mechanical top bracing
The mechanical top bracing comprises stiff con-
nections between the engine and the hull.
The top bracing stiffener consists of a double
bar tightened with friction shims at each end of
the mounting positions. The friction shims al-
low the top bracing stiffener to move in case of
displacements caused by thermal expansion of
the engine or different loading conditions of the
vessel. Furthermore, the tightening is made with a
well-dened force on the friction shims, using disc
springs, to prevent overloading of the system in
case of an excessive vibration level.
Engine Top Bracing
MAN B&W MC/MCC, ME/MEC/MEGI/ME-B engines 198 46 725.8
MAN B&W 5.13
Page 2 of 2
MAN Diesel MAN Diesel
The mechanical top bracing is to be made by the
shipyard in accordance with MAN Diesel instruc-
tions.
178 23 61-6.1
Fig. 5.13.01: Mechanical top bracing stiffener.
Option: 4 83 112
Hydraulic top bracing
The hydraulic top bracing is an alternative to the
mechanical top bracing used mainly on engines
with a cylinder bore of 50 or more. The installation
normally features two, four or six independently
working top bracing units.
The top bracing unit consists of a single-acting hy-
draulic cylinder with a hydraulic control unit and an
accumulator mounted directly on the cylinder unit.
The top bracing is controlled by an automatic
switch in a control panel, which activates the top
bracing when the engine is running. It is possi-
ble to programme the switch to choose a certain
rpm range, at which the top bracing is active. For
service purposes, manual control from the control
panel is also possible.
When active, the hydraulic cylinder provides a
pressure on the engine in proportion to the vibra-
tion level. When the distance between the hull and
engine increases, oil ows into the cylinder under
pressure from the accumulator. When the dis-
tance decreases, a non-return valve prevents the
oil from owing back to the accumulator, and the
pressure rises. If the pressure reaches a preset
maximum value, a relief valve allows the oil to ow
back to the accumulator, hereby maintaining the
force on the engine below the specied value.
By a different pre-setting of the relief valve, the
top bracing is delivered in a low-pressure version
(26 bar) or a high-pressure version (40 bar).
The top bracing unit is designed to allow dis-
placements between the hull and engine caused
by thermal expansion of the engine or different
loading conditions of the vessel.
178 57 48-8.0
Fig. 5.13.02: Outline of a hydraulic top bracing unit.
The unit is installed with the oil accumulator pointing
either up or down. Option: 4 83 123
AA
A
A
Hydraulic Control Unit
Oil Accumulator
Cylinder Unit
2
5
0
1
4
3
5
0
6
8
4
3
2
0
2
8
0
475
Engine side Hull side
MAN B&W 5.14
Page 1 of 1
MAN Diesel
MAN B&W 98-50 ME/ME-C Engine Selection Guide 198 79 39-2.0
Table 5.15.02: Mechanical top bracing force and
deection
Force per mechanical top bracing and maximum
horizontal deection at attachment to the hull
Cyl.: 5 6 7 8 9 10 11 12
Force per
bracing in
kN
Motor type Number of top bracings
K98ME-C
Available on request
K98ME
S90ME-C 6 6 7 7 209
K90ME-C 6 6 7 7 8 9 10 209
K90ME 6 6 7 7 8 9 10 209
S80ME-C 5 6 6 7 165
K80ME-C 5 6 6 7 8 9 10 165
S70ME-C 4 5 6 6 126
L70ME-C 4 5 6 6 126
S65ME-C 4 5 6 6 93
S60ME-C 4 5 6 6 93
L60ME-C 4 5 6 6 7 93
S50ME-C 4 5 5 6 6 64
Mechanical top bracing arrangement
Fig. 5.15.01: Mechanical top bracing arrangement
178 61 93-5.0
1
Centre line
crankshaft
MAN B&W 5.15
Page 1 of 1
MAN Diesel
MAN B&W 98-50 ME/ME-C Engine Selection Guide 198 39 213.6
Table 5.15.02: Hydraulic top bracing force and deection
Force per hydraulic top bracing and maximum
horizontal deection at attachment to the hull
Cyl.: 5 6 7 8 9 10 11 12 14
Force per
bracing in
kN
Motor type Number of top bracings
K98ME-C 4 4 4 4 4 6 6 8 125,7
K98ME 4 4 4 4 4 6 6 8 125,7
S90ME-C 4 4 4 4 125,7
K90ME-C 4 4 4 4 4 4 4 125,7
K90ME 4 4 4 4 4 4 4 125,7
S80ME-C 4 4 4 4 125,7
K80ME-C 4 4 4 4 4 4 4 125,7
S70ME-C 4 4 4 2 125,7
L70ME-C 4 4 4 2 125,7
S65ME-C 4 4 4 4 81,7
S60ME-C 4 4 4 4 81,7
L60ME-C 4 4 4 4 4 81,7
S50ME-C 2 2 2 2 2 81,7
Hydraulic top bracing arrangement
Fig. 5.15.01: Hydraulic top bracing arrangement
178 50 184.0
Centre line
crankshaft
Centre line
MAN B&W 5.16
Page 1 of 4
MAN Diesel
MAN B&W ME/ME-C/ME-GI/MEB engines 198 46 977.4
Components for Engine Control System
Installation of ECS in the Engine Control Room
The following items are to be installed in the ECR
(Engine Control Room):
2 pcs EICU (Engine Interface Control Unit)
(1 pcs only for ME-B engines)
1 pcs MOP (Main Operating Panel)
Touch display, 15
PC unit
1 pcs Track ball for MOP
1 pcs PMI system
Display, 19
PC unit
1 pcs Backup MOP
Display, 15
PC unit
Keyboard
1 pcs Printer
1 pcs Ethernet Hub
The EICU functions as an interface unit to ECR
related systems such as AMS (Alarm and Monitor-
ing System), RCS (Remote Control System) and
Safety System. On ME-B engines the EICU also
controls the HPS.
The MOP is the operators interface to the ECS.
From there the operator can control and see sta-
tus of the engine and the ECS. The MOP is a PC
with a at touch screen.
The Backup MOP consists of a PC unit with
keyboard and display and serves as a backup in
case the MOP should break down.
The PMI ofine system is equipped with a stand-
ard PC. The PMI system serves as a pressure
analyse system. See Section 18.02.
Optional items to be mounted in the ECR include
the CoCoSEDS which can be purchased sepa-
rately and applied on the PC for the PMI ofine
system. See Section 18.03.
MOP A MOP B
Printer
ECS Network A
Ethernet
Ethernet, supply with HUB, cable length 10 meter


E
t
h
e
r
n
e
t
PMI/CoCoS PC HUB
Serial AMS #
Ethernet (AMS)
Ship LAN #
ECS Network B
# Yard Supply
Ethernet
Fig. 5.16.01 Network and PC components for the ME/ME-B Engine Control System
178 57 50-3.0
MAN B&W 5.16
Page 2 of 4
MAN Diesel
MAN B&W ME/ME-C/ME-GI/MEB engines 198 46 977.4
MOP (Main Operating Panel)
Track ball
178 57 48-1.0
Fig. 5.16.02 MOP and track ball for the ME/ME-B Engine Control System
110
1
1
5
17
30
60
104.5 412
3
4
5
1
1
.
4
40
MAN B&W 5.16
Page 3 of 4
MAN Diesel
MAN B&W ME/ME-C/ME-GI/MEB engines 198 46 977.4
178 50 147.1
Fig. 5.16.03 The EICU cabinet and MOP PC unit for the ME/ME-B Engine Control System
EICU (Engine Interface Control Unit) Cabinet
400 210
5
0
0
Note 2
Note:
2 Clearance for air cooling 50mm
3 Clearance for Cable 150 mm
Note 3
528
381
2
5
0
6
6
457.8
420
478
MOP PC unit
MAN B&W 5.16
Page 4 of 4
MAN Diesel
MAN B&W ME/ME-C/ME-GI/MEB engines 198 46 977.4
PC parts for PMI/CoCoS
178 57 49-3.0
Fig. 5.16.04 PMI/CoCoS PC unit, display and printer for the ME/ME-B Engine Control System
205
4
0
4
.
7
2
3
4
3
413
238
537 450
1
4
4
458
2
1
1
442
19 Display
PC unit
Printer
MAN B&W 5.17
Page 1 of 3
MAN Diesel MAN Diesel
198 49 292.4 MAN B&W MC/MCC, ME/MEC/ME-GI/ME-B engines
Shaftline Earthing Device
Scope and eld of application
A difference in the electrical potential between the
hull and the propeller shaft will be generated due
to the difference in materials and to the propeller
being immersed in sea water.
In some cases, the difference in the electrical
potential has caused spark erosion on the thrust,
main bearings and journals of the crankshaft of
the engine.
In order to reduce the electrical potential between
the crankshaft and the hull and thus prevent spark
erosion, a highly efcient shaftline earthing device
must be installed.
The shaftline earthing device should be able to
keep the electrical potential difference below 50
mV DC. A shaft-to-hull monitoring equipment with
a mV-meter and with an output signal to the alarm
system must be installed so that the potential and
thus the correct function of the shaftline earthing
device can be monitored.
Note that only one shaftline earthing device is
needed in the propeller shaft system.
Design description
The shaftline earthing device consists of two silver
slip rings, two arrangements for holding brushes
including connecting cables and monitoring
equipment with a mV-meter and an output signal
for alarm.
The slip rings should be made of solid silver or
back-up rings of cobber with a silver layer all over.
The expected life span of the silver layer on the
slip rings should be minimum 5 years.
The brushes should be made of minimum 80%
silver and 20% graphite to ensure a sufcient
electrical conducting capability.
Resistivity of the silver should be less than 0.1
Ohm x m. The total resistance from the shaft to
the hull must not exceed 0.001 Ohm.
Cabling of the shaftline earthing device to the hull
must be with a cable with a cross section not less
than 45 mm. The length of the cable to the hull
should be as short as possible.
Monitoring equipment should have a 4-20 mA
signal for alarm and a mV-meter with a switch for
changing range. Primary range from 0 to 50 mV
DC and secondary range from 0 to 300 mV DC.
When the shaftline earthing device is working
correctly, the electrical potential will normally be
within the range of 10-50 mV DC depending of
propeller size and revolutions.
The alarm set-point should be 80 mV for a high
alarm. The alarm signals with an alarm delay of 30
seconds and an alarm cut-off, when the engine is
stopped, must be connected to the alarm system.
Connection of cables is shown in the sketch, see
Fig. 5.17.01.
MAN B&W 5.17
Page 2 of 3
MAN Diesel MAN Diesel
198 49 292.4 MAN B&W MC/MCC, ME/MEC/ME-GI/ME-B engines
Rudder
Voltage monitoring
for shafthull potential
difference
Shaftline
earthing device
V
Propeller shaft
Intermediate shaft
Intermediate shaft bearing
Current
Thrust bearing
Main bearings
Propeller
079 21 82-1.3.2.0
Fig. 5.17.02: Installation of shaftline earthing device in an engine plant without shaft-mounted generator
Shaftline earthing device installations
The shaftline earthing device slip rings must be
mounted on the foremost intermediate shaft as
close to the engine as possible, see Fig. 5.17.02
Brush holder
arrangement
Cable
connected
to the hull
Monitoring
equipment
with mVmeter
Cable
connected
to the hull
Cable
to alarm
system
Brush holder
arrangement
Slip ring
for monitoring
equipment
Slip ring
Fig. 5.17.01: Connection of cables for the shaftline earthing device
079 21 82-1.3.1.0
MAN B&W 5.17
Page 3 of 3
MAN Diesel MAN Diesel
198 49 292.4 MAN B&W MC/MCC, ME/MEC/ME-GI/ME-B engines
Rudder
Voltage monitoring
for shafthull potential
difference
Shaftline
earthing device
V
Propeller shaft
Intermediate shaft
Intermediate shaft bearing
Current
Thrust bearing
Main bearings
Propeller
Shaft mounted alternator
where the rotor is part of
the intermediate shaft
079 21 82-1.3.3.0
Fig. 5.17.03: Installation of shaftline earthing device in an engine plant with shaft-mounted generator
When a generator is tted in the propeller shaft
system, where the rotor of the generator is part of
the intermediate shaft, the shaftline earthing de-
vice must be mounted between the generator and
the engine, see Fig. 5.17.03
MAN B&W
Page 1 of 1
MAN Diesel
This section is not applicable
for
98-80 MC/MC-C/ME/ME-C
MAN Diesels Alpha Controllable Pitch Propeller and Alphatronic Propulsion Control
5.18
198 79 50-9.0 MAN B&W K98MC/MC-C/ME/ME-C, S90MC-C/ME-C,
K90MC-C/ME-C, S80MC-C/ME-C, K80MC-C/ME-C
MAN B&W 5.18
Page 1 of 8
MAN Diesel
198 46 953.5 MAN B&W S70MC, S70MC-C/ME-C/ME-C-GI, L70MC-C/ME-C,
S65ME-C/ME-C-GI, S60MC, S60MC-C/ME-C/ME-C-GI/ME-B,
L60MC-C/ME-C, S50MC, S50MC-C/ME-C/ME-B, S46MC-C/ME-B,
S42MC, S40MC-C/ME-B, S35MC, S35MC-C/ME-B, L35MC, S26MC
VBS type CP propeller designation and range
The VBS type CP propellers are designated ac-
cording to the diameter of their hubs, i.e. VBS2240
indicates a propeller hub diameter of 2,240 mm.
The standard VBS type CP propeller programme,
its diameters and the engine power range covered
is shown in Fig. 5.18.01.
The servo oil system controlling the setting of the
propeller blade pitch is shown in Fig.5.18.05.
MAN Diesels Alpha Controllable Pitch Propeller and Alphatronic Propulsion Control
MAN Diesels Alpha Controllable Pitch propeller
On MAN Diesels Alpha VBS type Controllable
Pitch (CP) propeller, the hydraulic servo motor
setting the pitch is built into the propeller hub. A
range of different hub sizes is available to select
an optimum hub for any given combination of
power, revolutions and ice class.
Standard blade/hub materials are NiAlbronze.
Stainless steel is available as an option. The pro-
pellers are based on no ice class but are avail-
able up to the highest ice classes.
0
1,000
2,000
3,000
4,000
5,000
6,000
7,000
8,000
9,000
0 5 10 15 20 25 30 35 40
Engine Power (1,000 kW)
10,000
Propeller Diameter (mm)
V
B
S
6
4
0
V
B
S
7
4
0
V
B
S
8
6
0
V
B
S
9
8
0
V
B
S
1
0
8
0
V
B
S
118
0
VB
S1280
VBS1380
VBS1460
VBS1560
VBS1680
VBS1800
VBS1940
VBS2080
VBS2240
178 22 239.1
Fig. 5.18.01: VBS type Controllable Pitch (CP) propeller diameter (mm)
MAN B&W 5.18
Page 2 of 8
MAN Diesel
198 46 953.5
MAN B&W S70MC, S70MC-C/ME-C/ME-C-GI, L70MC-C/ME-C,
S65ME-C/ME-C-GI, S60MC, S60MC-C/ME-C/ME-C-GI/ME-B,
L60MC-C/ME-C, S50MC, S50MC-C/ME-C/ME-B, S46MC-C/ME-B,
S42MC, S40MC-C/ME-B, S35MC, S35MC-C/ME-B, L35MC, S26MC
Data Sheet for Propeller
Identication: _______________________________
178 22 360.0
Table 5.18.02b: Data sheet for propeller design purposes
Type of vessel: ______________________________
For propeller design purposes please provide us
with the following information:
1. S: ______________ mm
W: _____________ mm
I: _______________ mm (as shown above)
2. Stern tube and shafting arrangement layout
3. Propeller aperture drawing
4. Complete set of reports from model tank (re-
sistance test, selfpropulsion test and wake
measurement). In case model test is not avail-
able the next page should be lled in.
5. Drawing of lines plan
6. Classication Society: __________
Ice class notation: _____________
7. Maximum rated power of shaft generator: kW
8. Optimisation condition for the propeller:
To obtain the highest propeller efciency
please identify the most common service con-
dition for the vessel.
Ship speed: ___________________________ kn
Engine service load: ____________________ %
Service/sea margin: ____________________ %
Shaft generator service load: ____________ kW
Draft: _________________________________ m
9. Comments:
I W S
Fig. 5.18.02a: Dimension sketch for propeller design purposes
MAN B&W 5.18
Page 3 of 8
MAN Diesel
198 46 953.5 MAN B&W S70MC, S70MC-C/ME-C/ME-C-GI, L70MC-C/ME-C,
S65ME-C/ME-C-GI, S60MC, S60MC-C/ME-C/ME-C-GI/ME-B,
L60MC-C/ME-C, S50MC, S50MC-C/ME-C/ME-B, S46MC-C/ME-B,
S42MC, S40MC-C/ME-B, S35MC, S35MC-C/ME-B, L35MC, S26MC
Main Dimensions
Symbol Unit Ballast Loaded
Length between perpendiculars LPP m
Length of load water line LWL m
Breadth B m
Draft at forward perpendicular TF m
Draft at aft perpendicular TA m
Displacement o m3
Block coefcient (LPP) CB
Midship coefcient CM
Waterplane area coefcient CWL
Wetted surface with appendages S m2
Centre of buoyancy forward of LPP/2 LCB m
Propeller centre height above baseline H m
Bulb section area at forward perpendicular AB m2
178 22 970.0
Table 5.18.03: Data sheet for propeller design purposes, in case model test is not available this table should be lled in
Propeller clearance
To reduce pressure impulses and vibrations emit-
ted from the propeller to the hull, MAN Diesel
recommend a minimum tip clearance as shown in
Fig. 5.18.04.
For ships with slender aft body and favourable
inow conditions the lower values can be used,
whereas full afterbody and large variations in
wake eld cause the upper values to be used.
In twinscrew ships the blade tip may protrude
below the base line.
Hub
Dismant-
ling
of cap
X mm
High skew
propeller
Y mm
Nonskew
propeller
Y mm
Baseline
clearance
Z mm
VBS 1280 390
1520%
of D
2025%
of D
Min.
50100
VBS 1380 420
VBS 1460 450
VBS 1560 480
VBS 1680 515
VBS 1800 555
VBS 1940 590
VBS 2080 635
VBS 2240 680
178 48 589.0
Fig. 5.18.04: Propeller clearance
178 22 372.0
Z
D
Y
X
Baseline
MAN B&W 5.18
Page 4 of 8
MAN Diesel
198 46 953.5
MAN B&W S70MC, S70MC-C/ME-C/ME-C-GI, L70MC-C/ME-C,
S65ME-C/ME-C-GI, S60MC, S60MC-C/ME-C/ME-C-GI/ME-B,
L60MC-C/ME-C, S50MC, S50MC-C/ME-C/ME-B, S46MC-C/ME-B,
S42MC, S40MC-C/ME-B, S35MC, S35MC-C/ME-B, L35MC, S26MC
If deviation occurs, a proportional valve is actu-
ated. Hereby high pressure oil is fed to one or the
other side of the servo piston, via the oil distribu-
tor ring, until the desired propeller pitch has been
reached.
The pitch setting is normally remote controlled,
but local emergency control is possible.
Fig. 5.18.05: Servo oil system for MAN Diesels Alpha VBS type CP propeller
178 22 384.1
Servo oil system for VBS type CP propeller
The design principle of the servo oil system for
MAN Diesels Alpha VBS type CP propeller is
shown in Fig. 5.18.05.
The VBS system consists of a servo oil tank unit,
the Hydraulic Power Unit, and a coupling ange
with electrical pitch feedback box and oil distribu-
tor ring.
The electrical pitch feedback box continuously
measures the position of the pitch feedback ring
and compares this signal with the pitch order sig-
nal.
Hydraulic Power Unit
Stern
tube oil
tank
Oil tank
forward
seal
Pitch
order
Servo
piston
Lip ring seals
Hydraulic
pipe
Pitch
feedback
Drain
tank
Propeller shaft
Oil distribution
ring
Stern
tube
Monoblock
hub
Zinc
anode
M M
PSL PSL
PAL
PAL PAH PI
M M
PI
LAL
TAH
TI
MAN B&W 5.18
Page 5 of 8
MAN Diesel
198 53 208.2 MAN B&W S70MC, S70MC-C/ME-C/ME-C-GI, L70MC-C/ME-C,
S65ME-C/ME-C-GI, S60MC, S60MC-C/ME-C/ME-C-GI/ME-B,
L60MC-C/ME-C, S50MC, S50MC-C/ME-C/ME-B, S46MC-C/ME-B,
S42MC, S40MC-C/ME-B, S35MC, S35MC-C/ME-B, L35MC, S26MC
178 22 396.0
Fig. 5.18.06: Hydraulic Power Unit for MAN Diesels Alpha CP propeller, the servo oil tank unit
Hydraulic Power Unit for Alpha CP propeller
The servo oil tank unit, the Hydraulic Power Unit
for MAN Diesels Alpha CP propeller shown in Fig.
5.18.06, consists of an oil tank with all other com-
ponents top mounted to facilitate installation at
yard.
Two electrically driven pumps draw oil from the oil
tank through a suction lter and deliver high pres-
sure oil to the proportional valve.
One of two pumps are in service during normal
operation, while the second will start up at power-
ful manoeuvring.
A servo oil pressure adjusting valve ensures mini-
mum servo oil pressure at any time hereby mini-
mizing the electrical power consumption.
Maximum system pressure is set on the safety
valve.
The return oil is led back to the tank via a thermo-
static valve, cooler and paper lter.
The servo oil unit is equipped with alarms accord-
ing to the Classication Societys requirements
as well as necessary pressure and temperature
indicators.
If the servo oil unit cannot be located with maxi-
mum oil level below the oil distribution ring, the
system must incorporate an extra, small drain
tank complete with pump, located at a suitable
level, below the oil distributor ring drain lines.
MAN B&W 5.18
Page 6 of 8
MAN Diesel
198 53 221.3 MAN B&W S70MC, S70MC-C/ME-C/ME-C-GI, L70MC-C/ME-C,
S65ME-C/ME-C-GI, S60MC, S60MC-C/ME-C/ME-C-GI/ME-B,
L60MC-C/ME-C, S50MC, S50MC-C/ME-C/ME-B, S46MC-C/ME-B,
S42MC, S40MC-C/ME-B, S35MC, S35MC-C/ME-B, L35MC, S26MC
RPM Pitch
Coordinated
Control
System
Handles
interface
Duplicated Network
Engine
safety
system
Engine speed
System failure alarm, Load reduction, Load red. Cancel alarm
Engine overload (max. load)
S
T
O
P
Governor limiter cancel
RPM Pitch
I
Start/Stop/Slow turning, Start blocking, Remote/Local
Ahead/
Astern
Remote/Local
Fuel Index
Charge Air Press.
Terminals for
propeller
monitoring
sensors
P
I
Pitch
Pitch Set
Local engine
control
Speed Set
Propulsion
Control
System
Bridge Wing
Shut down, Shut down reset/cancel
Propeller Pitch
Closed Loop
Control Box
Pitch
Operator
Panel (*)
Operator
Panel
Operator
Panel
Backup selected
Shaft Generator
/ PMS
Auxiliary Control
Equipment
Ships
Alarm
System
ES
Main Control Station
(Center) Bridge Wing
BU: BackUp Control
Bridge
Engine Control Room
Engine Room
STOP
P
I
P
I
S
T
A
R
T
Operator
Panel (*)
RPM Pitch RPM Pitch
ES: Emergency Stop
ES BU ES
Operator
Panel
(OPP)
Terminals for
engine monitoring
sensors
S
T
O
P
(
I
n

g
o
v
e
r
n
o
r
)
G
o
v
e
r
n
o
r
OVER
LOAD
178 22 406.1
Fig. 5.18.07: MAN Diesels Alphatronic 2000 Propulsion Control System
Alphatronic 2000 Propulsion Control System
MAN Diesels Alphatronic 2000 Propulsion Control
System (PCS) is designed for control of propul-
sion plants based on diesel engines with CP pro-
pellers. The plant could for instance include tunnel
gear with PTO/PTI, PTO gear, multiple engines on
one gearbox as well as multiple propeller plants.
As shown in Fig. 5.18.07, the propulsion control
system comprises a computer controlled system
with interconnections between control stations via
a redundant bus and a hard wired backup control
system for direct pitch control at constant shaft
speed.
The computer controlled system contains func-
tions for:
Machinery control of engine start/stop, engine
load limits and possible gear clutches.
Thrust control with optimization of propeller
pitch and shaft speed. Selection of combina-
tor, constant speed or separate thrust mode is
possible. The rates of changes are controlled to
ensure smooth manoeuvres and avoidance of
propeller cavitation.
A Load control function protects the engine
against overload. The load control function con-
tains a scavenge air smoke limiter, a load pro-
gramme for avoidance of high thermal stresses
in the engine, an automatic load reduction and
an engineer controlled limitation of maximum
load.
Functions for transfer of responsibility be-
tween the local control stand, engine control
room and control locations on the bridge are
incorporated in the system.
MAN B&W 5.18
Page 7 of 8
MAN Diesel
198 53 221.3 MAN B&W S70MC, S70MC-C/ME-C/ME-C-GI, L70MC-C/ME-C,
S65ME-C/ME-C-GI, S60MC, S60MC-C/ME-C/ME-C-GI/ME-B,
L60MC-C/ME-C, S50MC, S50MC-C/ME-C/ME-B, S46MC-C/ME-B,
S42MC, S40MC-C/ME-B, S35MC, S35MC-C/ME-B, L35MC, S26MC
2
8
8
BACK UP
CONTROL
ON/OFF
144
288
IN
CONTROL CONTROL
TAKE
BACK UP
CONTROL
ON/OFF
IN
CONTROL
TAKE
CONTROL
PROPELLER
RPM
PROPELLER
PITCH
178 22 418.1
Fig. 5.18.08: Main bridge station standard layout
Propulsion control station on the main bridge
For remote control, a minimum of one control sta-
tion located on the bridge is required.
This control station will incorporate three mod-
ules, as shown in Fig. 5.18.08:
Propulsion control panel with push buttons
and indicators for machinery control and a dis-
play with information of condition of operation
and status of system parameters.
Propeller monitoring panel with backup in-
struments for propeller pitch and shaft speed.
Thrust control panel with control lever for
thrust control, an emergency stop button and
push buttons for transfer of control between
control stations on the bridge.
MAN B&W 5.18
Page 8 of 8
MAN Diesel
198 53 221.3 MAN B&W S70MC, S70MC-C/ME-C/ME-C-GI, L70MC-C/ME-C,
S65ME-C/ME-C-GI, S60MC, S60MC-C/ME-C/ME-C-GI/ME-B,
L60MC-C/ME-C, S50MC, S50MC-C/ME-C/ME-B, S46MC-C/ME-B,
S42MC, S40MC-C/ME-B, S35MC, S35MC-C/ME-B, L35MC, S26MC
Renk KAZ Clutch for auxilliary propulsion sys-
tems
The Renk KAZ Clutch is a shaftline declutching
device for auxilliary propulsion systems which
meets the class notations for redundant propul-
sion.
The Renk KAZ clutch facilitates reliable and
simple take home and take away functions in
twostroke engine plants. It is described in Sec-
tion 4.04.
Further information about Alpha CP propeller
For further information about MAN Diesels Alpha
Controllable Pitch (CP) propeller and the Alpha-
tronic 2000 Remote Control System, please refer
to our publications:
CP Propeller Product Information
Alphatronic 2000 PCS Propulsion Control System
The publications are available at
www.mandieselturbo.com under Products
Marine Engines & Systems Low Speed
Technical Papers.
MAN B&W
MAN Diesel
List of Capacities:
Pumps, Coolers &
Exhaust Gas

6
MAN B&W 6.01
Page 1 of 1
MAN Diesel
198 70 67-9.2 MAN B&W K98ME/ME-C-TII, S90ME-C-TII, K90ME/ME-C-TII,
S80ME-C-TII, K80ME-C-TII, L/S70ME-C-TII, S65ME-C-TII,
L/S60ME-C-TII, S50ME-C-TII
Calculation of List of Capacities and Exhaust Gas Data
Updated engine and capacities data is available
from the CEAS program on www.mandiesel-
turbo.com under Products Marine Engines &
Systems Low Speed CEAS - Engine Room
Dimensioning.
This chapter describes the necessary auxiliary ma-
chinery capacities to be used for a nominally rated
engine. The capacities given are valid for seawater
cooling system and central cooling water system,
respectively. For derated engine, i.e. with a speci-
ed MCR and/or matching point different from the
nominally rated MCR point, the list of capacities
will be different from the nominal capacities.
Furthermore, among others, the exhaust gas data
depends on the ambient temperature conditions.
Based on examples for a derated engine, the way
of how to calculate the derated capacities, fresh-
water production and exhaust gas amounts and
temperatures will be described in details.
Nomenclature
In the following description and examples of the auxiliary machinery capacities, freshwater generator pro-
duction and exhaust gas data, the below nomenclatures are used:
Fig. 6.01.01: Nomenclature of basic engine ratings
Fig. 6.01.02: Nomenclature of coolers and volume ows, etc.
Engine congurations related to SFOC
The engine type is available in the following ver-
sion only with respect to the efciency of the tur-
bocharger:
With high efciency turbocharger, which is the
basic design and for which the lists of capacities
Section 6.03 are calculated.
Engine ratings Point / Index Power Speed
Nominal MCR point L
1
P
L1
n
L1
Specied MCR point M P
M
n
M
Matching point O P
O
n
O
Service point S P
S
n
S
Parameters
Q = Heat dissipation
V = Volume ow
M = Mass ow
T = Temperature
Cooler index
air scavenge air cooler
lub lube oil cooler
jw jacket water cooler
cent central cooler
Flow index
sw seawater ow
cw cooling/central water ow
exh exhaust gas
fw freshwater
MAN B&W 6.02
Page 1 of 1
MAN Diesel
198 74 63-3.0 MAN B&W MC/MC-C/ME/ME-C/ME-B/ME-GI-TII engines
List of Capacities and Cooling Water Systems
The capacities for the starting air receivers and
the compressors are stated in Fig. 6.03.01.
Heat radiation and air consumption
The radiation and convection heat losses to the
engine room is around 1% of the engine nominal
power (kW in L
1
).
The air consumption is approximately 98.2%
of the calculated exhaust gas amount, ie.
M
air
= M
exh
x 0.982.
Flanges on engine, etc.
The location of the anges on the engine are
shown in: Engine pipe connections, and the ang-
es are identied by reference letters stated in the
List of anges; both can be found in Chapter 5.
The diagrams use the Basic symbols for piping,
whereas the symbols for instrumentation accord-
ing to ISO 12191 and ISO 12192 and the in-
strumentation list found in Appendix A.
178 11 264.1
Fig. 6.02.01: Diagram for seawater cooling system
Scavenge air cooler
Seawater
32 C
45 C
Lubricating oil cooler
38 C
Jacket water cooler
80 C
Seawater outlet
Seawater outlet
Central
cooler
Seawater inlet
32 C
Central coolant
36 C
Scavenge
air
cooler (s)
Jaket
water
cooler
Lubricating
oil
cooler
80 C
43 C
45 C
Fig. 6.02.02: Diagram for central cooling water system
178 11 276.1
The List of Capacities contain data regarding the
necessary capacities of the auxiliary machinery
for the main engine only, and refer to a nominally
rated engine. Complying with IMO Tier II NO
x
limi-
tations.
The heat dissipation gures include 10% extra
margin for overload running except for the scav-
enge air cooler, which is an integrated part of the
diesel engine.
Cooling Water Systems
The capacities given in the tables are based on
tropical ambient reference conditions and refer to
engines with high efciency/conventional turbo-
charger running at nominal MCR (L
1
) for:
Seawater cooling system,
See diagram, Fig. 6.02.01 and nominal capaci-
ties in Fig. 6.03.01
Central cooling water system,
See diagram, Fig. 6.02.02 and nominal capaci-
ties in Fig. 6.03.01
MAN B&W 6.03
Page 1 of 1
MAN Diesel
MAN B&W ME/ME-C Engine Selection Guide 198 59 64-3.1
List of Capacities
Please note that the information is to be found in
the Project Guide for the relevant engine type.
Enclosed is an example of S70ME-C8-TII.
See www.mandieselturbo.com under Products
Marine Engines & Systems Low Speed
CEAS - Engine Room Dimensioning to calcu-
late list of capacities, enter engine specications.
MAN B&W 6.03
Page 1 of 4
MAN Diesel
MAN B&W S70ME-C8-TII 198 71 21-8.0
List of Capacities for 5S70ME-C8-TII at NMCR - IMO NO
x
Tier II compliance
Seawater cooling Central cooling
Conventional TC High eff. TC Conventional TC High eff. TC
---
1
x
T
C
A
7
7
-
2
1
1
x
A
1
8
5
-
L
3
4
1
x
M
E
T
8
3
M
A
---
1
x
T
C
A
7
7
-
2
1
1
x
A
1
8
5
-
L
3
4
1
x
M
E
T
8
3
M
A
Pumps
Fuel oil circulation m/h N.A. N.A. N.A. 6.5 6.5 6.5 N.A. N.A. N.A. 6.5 6.5 6.5
Fuel oil supply m/h N.A. N.A. N.A. 4.1 4.1 4.1 N.A. N.A. N.A. 4.1 4.1 4.1
Jacket cooling m/h N.A. N.A. N.A. 135.0 135.0 135.0 N.A. N.A. N.A. 135.0 135.0 135.0
Seawater cooling * m/h N.A. N.A. N.A. 530.0 530.0 540.0 N.A. N.A. N.A. 510.0 520.0 520.0
Main lubrication oil * m/h N.A. N.A. N.A. 325.0 325.0 330.0 N.A. N.A. N.A. 325.0 325.0 330.0
Central cooling * m/h - - - - - - - - - 410 410 410
Scavenge air cooler(s)
Heat diss. app. kW N.A. N.A. N.A. 6,820 6,820 6,820 N.A. N.A. N.A. 6,790 6,790 6,790
Central water flow m/h N.A. N.A. N.A. - - - N.A. N.A. N.A. 235 235 235
Seawater flow m/h N.A. N.A. N.A. 353 353 353 N.A. N.A. N.A. - - -
Lubricating oil cooler
Heat diss. app. * kW N.A. N.A. N.A. 1,280 1,310 1,320 N.A. N.A. N.A. 1,280 1,310 1,320
Lube oil flow * m/h N.A. N.A. N.A. 325.0 325.0 330.0 N.A. N.A. N.A. 325.0 325.0 330.0
Central water flow m/h N.A. N.A. N.A. - - - N.A. N.A. N.A. 175 175 175
Seawater flow m/h N.A. N.A. N.A. 177 177 187 N.A. N.A. N.A. - - -
Jacket water cooler
Heat diss. app. kW N.A. N.A. N.A. 2,370 2,370 2,370 N.A. N.A. N.A. 2,370 2,370 2,370
Jacket water flow m/h N.A. N.A. N.A. 135 135 135 N.A. N.A. N.A. 135 135 135
Central water flow m/h N.A. N.A. N.A. - - - N.A. N.A. N.A. 175 175 175
Seawater flow m/h N.A. N.A. N.A. 177 177 187 N.A. N.A. N.A. - - -
Central cooler
Heat diss. app. * kW N.A. N.A. N.A. - - - N.A. N.A. N.A. 10,440 10,470 10,480
Central water flow m/h N.A. N.A. N.A. - - - N.A. N.A. N.A. 410 410 410
Seawater flow m/h N.A. N.A. N.A. - - - N.A. N.A. N.A. 510 520 520
Starting air system, 30.0 bar g, 12 starts. Fixed pitch propeller - reversible engine
Receiver volume m N.A. N.A. N.A. 2 x 7.5 2 x 7.5 2 x 7.5 N.A. N.A. N.A. 2 x 7.5 2 x 7.5 2 x 7.5
Compressor cap. m N.A. N.A. N.A. 450 450 450 N.A. N.A. N.A. 450 450 450
Starting air system, 30.0 bar g, 6 starts. Controllable pitch propeller - non-reversible engine
Receiver volume m N.A. N.A. N.A. 2 x 4.0 2 x 4.0 2 x 4.0 N.A. N.A. N.A. 2 x 4.0 2 x 4.0 2 x 4.0
Compressor cap. m N.A. N.A. N.A. 240 240 240 N.A. N.A. N.A. 240 240 240
Other values
Fuel oil heater kW N.A. N.A. N.A. 170 170 170 N.A. N.A. N.A. 170 170 170
Exh. gas temp. C N.A. N.A. N.A. 245 245 245 N.A. N.A. N.A. 245 245 245
Exh. gas amount kg/h N.A. N.A. N.A. 146,500 146,500 146,500 N.A. N.A. N.A. 146,500 146,500 146,500
Air consumption kg/h N.A. N.A. N.A. 39.9 39.9 39.9 N.A. N.A. N.A. 39.9 39.9 39.9
* For main engine arrangements with built-on power take-off (PTO) of a MAN Diesel recommended type and/or torsional vibration
damper the engine's capacities must be increased by those stated for the actual system
For List of Capacities for derated engines and performance data at part load please visit http://www.manbw.dk/ceas/erd/
Table 6.03.01e: Capacities for seawater and central systems as well as conventional and high efficiency turbochargers stated at NMCR
MAN B&W 6.03
Page 2 of 4
MAN Diesel
198 71 21-8.0 MAN B&W S70ME-C8-TII
List of Capacities for 6S70ME-C8-TII at NMCR - IMO NO
x
Tier II compliance
Seawater cooling Central cooling
Conventional TC High eff. TC Conventional TC High eff. TC
---
1
x
T
C
A
8
8
-
2
1
1
x
A
1
9
0
-
L
3
4
1
x
M
E
T
8
3
M
A
---
1
x
T
C
A
8
8
-
2
1
1
x
A
1
9
0
-
L
3
4
1
x
M
E
T
8
3
M
A
Pumps
Fuel oil circulation m/h N.A. N.A. N.A. 7.8 7.8 7.8 N.A. N.A. N.A. 7.8 7.8 7.8
Fuel oil supply m/h N.A. N.A. N.A. 4.9 4.9 4.9 N.A. N.A. N.A. 4.9 4.9 4.9
Jacket cooling m/h N.A. N.A. N.A. 165.0 165.0 165.0 N.A. N.A. N.A. 165.0 165.0 165.0
Seawater cooling * m/h N.A. N.A. N.A. 640.0 640.0 640.0 N.A. N.A. N.A. 620.0 620.0 620.0
Main lubrication oil * m/h N.A. N.A. N.A. 390.0 385.0 390.0 N.A. N.A. N.A. 390.0 385.0 390.0
Central cooling * m/h - - - - - - - - - 495 495 495
Scavenge air cooler(s)
Heat diss. app. kW N.A. N.A. N.A. 8,190 8,190 8,190 N.A. N.A. N.A. 8,150 8,150 8,150
Central water flow m/h N.A. N.A. N.A. - - - N.A. N.A. N.A. 283 283 283
Seawater flow m/h N.A. N.A. N.A. 424 424 424 N.A. N.A. N.A. - - -
Lubricating oil cooler
Heat diss. app. * kW N.A. N.A. N.A. 1,530 1,560 1,550 N.A. N.A. N.A. 1,530 1,560 1,550
Lube oil flow * m/h N.A. N.A. N.A. 390.0 385.0 390.0 N.A. N.A. N.A. 390.0 385.0 390.0
Central water flow m/h N.A. N.A. N.A. - - - N.A. N.A. N.A. 212 212 212
Seawater flow m/h N.A. N.A. N.A. 216 216 216 N.A. N.A. N.A. - - -
Jacket water cooler
Heat diss. app. kW N.A. N.A. N.A. 2,840 2,840 2,840 N.A. N.A. N.A. 2,840 2,840 2,840
Jacket water flow m/h N.A. N.A. N.A. 165 165 165 N.A. N.A. N.A. 165 165 165
Central water flow m/h N.A. N.A. N.A. - - - N.A. N.A. N.A. 212 212 212
Seawater flow m/h N.A. N.A. N.A. 216 216 216 N.A. N.A. N.A. - - -
Central cooler
Heat diss. app. * kW N.A. N.A. N.A. - - - N.A. N.A. N.A. 12,520 12,550 12,540
Central water flow m/h N.A. N.A. N.A. - - - N.A. N.A. N.A. 495 495 495
Seawater flow m/h N.A. N.A. N.A. - - - N.A. N.A. N.A. 620 620 620
Starting air system, 30.0 bar g, 12 starts. Fixed pitch propeller - reversible engine
Receiver volume m N.A. N.A. N.A. 2 x 8.0 2 x 8.0 2 x 8.0 N.A. N.A. N.A. 2 x 8.0 2 x 8.0 2 x 8.0
Compressor cap. m N.A. N.A. N.A. 480 480 480 N.A. N.A. N.A. 480 480 480
Starting air system, 30.0 bar g, 6 starts. Controllable pitch propeller - non-reversible engine
Receiver volume m N.A. N.A. N.A. 2 x 4.5 2 x 4.5 2 x 4.5 N.A. N.A. N.A. 2 x 4.5 2 x 4.5 2 x 4.5
Compressor cap. m N.A. N.A. N.A. 270 270 270 N.A. N.A. N.A. 270 270 270
Other values
Fuel oil heater kW N.A. N.A. N.A. 205 205 205 N.A. N.A. N.A. 205 205 205
Exh. gas temp. C N.A. N.A. N.A. 245 245 245 N.A. N.A. N.A. 245 245 245
Exh. gas amount kg/h N.A. N.A. N.A. 175,800 175,800 175,800 N.A. N.A. N.A. 175,800 175,800 175,800
Air consumption kg/h N.A. N.A. N.A. 47.9 47.9 47.9 N.A. N.A. N.A. 47.9 47.9 47.9
* For main engine arrangements with built-on power take-off (PTO) of a MAN Diesel recommended type and/or torsional vibration
damper the engine's capacities must be increased by those stated for the actual system
For List of Capacities for derated engines and performance data at part load please visit http://www.manbw.dk/ceas/erd/
Table 6.03.01f: Capacities for seawater and central systems as well as conventional and high efficiency turbochargers stated at NMCR
MAN B&W 6.03
Page 3 of 4
MAN Diesel
MAN B&W S70ME-C8-TII 198 71 21-8.0
List of Capacities for 7S70ME-C8-TII at NMCR - IMO NO
x
Tier II compliance
Seawater cooling Central cooling
Conventional TC High eff. TC Conventional TC High eff. TC
---
1
x
T
C
A
8
8
-
2
1
1
x
T
P
L
9
1
-
B
1
2
2
x
M
E
T
6
6
M
A
---
1
x
T
C
A
8
8
-
2
1
1
x
T
P
L
9
1
-
B
1
2
2
x
M
E
T
6
6
M
A
Pumps
Fuel oil circulation m/h N.A. N.A. N.A. 9.1 9.1 9.1 N.A. N.A. N.A. 9.1 9.1 9.1
Fuel oil supply m/h N.A. N.A. N.A. 5.7 5.7 5.7 N.A. N.A. N.A. 5.7 5.7 5.7
Jacket cooling m/h N.A. N.A. N.A. 190.0 190.0 190.0 N.A. N.A. N.A. 190.0 190.0 190.0
Seawater cooling * m/h N.A. N.A. N.A. 750.0 750.0 750.0 N.A. N.A. N.A. 720.0 720.0 720.0
Main lubrication oil * m/h N.A. N.A. N.A. 455.0 455.0 460.0 N.A. N.A. N.A. 455.0 455.0 460.0
Central cooling * m/h - - - - - - - - - 570 580 580
Scavenge air cooler(s)
Heat diss. app. kW N.A. N.A. N.A. 9,560 9,560 9,560 N.A. N.A. N.A. 9,510 9,510 9,510
Central water flow m/h N.A. N.A. N.A. - - - N.A. N.A. N.A. 330 330 330
Seawater flow m/h N.A. N.A. N.A. 494 494 494 N.A. N.A. N.A. - - -
Lubricating oil cooler
Heat diss. app. * kW N.A. N.A. N.A. 1,770 1,840 1,820 N.A. N.A. N.A. 1,770 1,840 1,820
Lube oil flow * m/h N.A. N.A. N.A. 455.0 455.0 460.0 N.A. N.A. N.A. 455.0 455.0 460.0
Central water flow m/h N.A. N.A. N.A. - - - N.A. N.A. N.A. 240 250 250
Seawater flow m/h N.A. N.A. N.A. 256 256 256 N.A. N.A. N.A. - - -
Jacket water cooler
Heat diss. app. kW N.A. N.A. N.A. 3,310 3,310 3,310 N.A. N.A. N.A. 3,310 3,310 3,310
Jacket water flow m/h N.A. N.A. N.A. 190 190 190 N.A. N.A. N.A. 190 190 190
Central water flow m/h N.A. N.A. N.A. - - - N.A. N.A. N.A. 240 250 250
Seawater flow m/h N.A. N.A. N.A. 256 256 256 N.A. N.A. N.A. - - -
Central cooler
Heat diss. app. * kW N.A. N.A. N.A. - - - N.A. N.A. N.A. 14,590 14,660 14,640
Central water flow m/h N.A. N.A. N.A. - - - N.A. N.A. N.A. 570 580 580
Seawater flow m/h N.A. N.A. N.A. - - - N.A. N.A. N.A. 720 720 720
Starting air system, 30.0 bar g, 12 starts. Fixed pitch propeller - reversible engine
Receiver volume m N.A. N.A. N.A. 2 x 8.0 2 x 8.0 2 x 8.0 N.A. N.A. N.A. 2 x 8.0 2 x 8.0 2 x 8.0
Compressor cap. m N.A. N.A. N.A. 480 480 480 N.A. N.A. N.A. 480 480 480
Starting air system, 30.0 bar g, 6 starts. Controllable pitch propeller - non-reversible engine
Receiver volume m N.A. N.A. N.A. 2 x 4.5 2 x 4.5 2 x 4.5 N.A. N.A. N.A. 2 x 4.5 2 x 4.5 2 x 4.5
Compressor cap. m N.A. N.A. N.A. 270 270 270 N.A. N.A. N.A. 270 270 270
Other values
Fuel oil heater kW N.A. N.A. N.A. 240 240 240 N.A. N.A. N.A. 240 240 240
Exh. gas temp. C N.A. N.A. N.A. 245 245 245 N.A. N.A. N.A. 245 245 245
Exh. gas amount kg/h N.A. N.A. N.A. 205,100 205,100 205,100 N.A. N.A. N.A. 205,100 205,100 205,100
Air consumption kg/h N.A. N.A. N.A. 55.9 55.9 55.9 N.A. N.A. N.A. 55.9 55.9 55.9
* For main engine arrangements with built-on power take-off (PTO) of a MAN Diesel recommended type and/or torsional vibration
damper the engine's capacities must be increased by those stated for the actual system
For List of Capacities for derated engines and performance data at part load please visit http://www.manbw.dk/ceas/erd/
Table 6.03.01g: Capacities for seawater and central systems as well as conventional and high efficiency turbochargers stated at NMCR
MAN B&W 6.03
Page 4 of 4
MAN Diesel
198 71 21-8.0 MAN B&W S70ME-C8-TII
List of Capacities for 8S70ME-C8-TII at NMCR - IMO NO
x
Tier II compliance
Seawater cooling Central cooling
Conventional TC High eff. TC Conventional TC High eff. TC
---
1
x
T
C
A
8
8
-
2
5
1
x
T
P
L
9
1
-
B
1
2
2
x
M
E
T
6
6
M
A
---
1
x
T
C
A
8
8
-
2
5
1
x
T
P
L
9
1
-
B
1
2
2
x
M
E
T
6
6
M
A
Pumps
Fuel oil circulation m/h N.A. N.A. N.A. 10.4 10.4 10.4 N.A. N.A. N.A. 10.4 10.4 10.4
Fuel oil supply m/h N.A. N.A. N.A. 6.5 6.5 6.5 N.A. N.A. N.A. 6.5 6.5 6.5
Jacket cooling m/h N.A. N.A. N.A. 215.0 215.0 215.0 N.A. N.A. N.A. 215.0 215.0 215.0
Seawater cooling * m/h N.A. N.A. N.A. 850.0 850.0 850.0 N.A. N.A. N.A. 820.0 820.0 820.0
Main lubrication oil * m/h N.A. N.A. N.A. 520.0 520.0 520.0 N.A. N.A. N.A. 520.0 520.0 520.0
Central cooling * m/h - - - - - - - - - 650 660 660
Scavenge air cooler(s)
Heat diss. app. kW N.A. N.A. N.A. 10,920 10,920 10,920 N.A. N.A. N.A. 10,860 10,860 10,860
Central water flow m/h N.A. N.A. N.A. - - - N.A. N.A. N.A. 377 377 377
Seawater flow m/h N.A. N.A. N.A. 565 565 565 N.A. N.A. N.A. - - -
Lubricating oil cooler
Heat diss. app. * kW N.A. N.A. N.A. 2,000 2,080 2,050 N.A. N.A. N.A. 2,000 2,080 2,050
Lube oil flow * m/h N.A. N.A. N.A. 520.0 520.0 520.0 N.A. N.A. N.A. 520.0 520.0 520.0
Central water flow m/h N.A. N.A. N.A. - - - N.A. N.A. N.A. 273 283 283
Seawater flow m/h N.A. N.A. N.A. 285 285 285 N.A. N.A. N.A. - - -
Jacket water cooler
Heat diss. app. kW N.A. N.A. N.A. 3,780 3,780 3,780 N.A. N.A. N.A. 3,780 3,780 3,780
Jacket water flow m/h N.A. N.A. N.A. 215 215 215 N.A. N.A. N.A. 215 215 215
Central water flow m/h N.A. N.A. N.A. - - - N.A. N.A. N.A. 273 283 283
Seawater flow m/h N.A. N.A. N.A. 285 285 285 N.A. N.A. N.A. - - -
Central cooler
Heat diss. app. * kW N.A. N.A. N.A. - - - N.A. N.A. N.A. 16,640 16,720 16,690
Central water flow m/h N.A. N.A. N.A. - - - N.A. N.A. N.A. 650 660 660
Seawater flow m/h N.A. N.A. N.A. - - - N.A. N.A. N.A. 820 820 820
Starting air system, 30.0 bar g, 12 starts. Fixed pitch propeller - reversible engine
Receiver volume m N.A. N.A. N.A. 2 x 8.5 2 x 8.5 2 x 8.5 N.A. N.A. N.A. 2 x 8.5 2 x 8.5 2 x 8.5
Compressor cap. m N.A. N.A. N.A. 510 510 510 N.A. N.A. N.A. 510 510 510
Starting air system, 30.0 bar g, 6 starts. Controllable pitch propeller - non-reversible engine
Receiver volume m N.A. N.A. N.A. 2 x 4.5 2 x 4.5 2 x 4.5 N.A. N.A. N.A. 2 x 4.5 2 x 4.5 2 x 4.5
Compressor cap. m N.A. N.A. N.A. 270 270 270 N.A. N.A. N.A. 270 270 270
Other values
Fuel oil heater kW N.A. N.A. N.A. 275 275 275 N.A. N.A. N.A. 275 275 275
Exh. gas temp. C N.A. N.A. N.A. 245 245 245 N.A. N.A. N.A. 245 245 245
Exh. gas amount kg/h N.A. N.A. N.A. 234,400 234,400 234,400 N.A. N.A. N.A. 234,400 234,400 234,400
Air consumption kg/h N.A. N.A. N.A. 63.9 63.9 63.9 N.A. N.A. N.A. 63.9 63.9 63.9
* For main engine arrangements with built-on power take-off (PTO) of a MAN Diesel recommended type and/or torsional vibration
damper the engine's capacities must be increased by those stated for the actual system
For List of Capacities for derated engines and performance data at part load please visit http://www.manbw.dk/ceas/erd/
Table 6.03.01h: Capacities for seawater and central systems as well as conventional and high efficiency turbochargers stated at NMCR
MAN B&W 6.04
Page 1 of 12
MAN Diesel
198 71 52-9.0 MAN B&W S90ME-C8-TII, S80ME-C8/9-TII,
K80ME-C6-TII, S70ME-C/ME-GI8-TII,
S65ME-C/ME-GI8-TII, S60ME-C/ME-GI8-TII,
L60ME-C7/8-TII, S50ME-C8-TII
Auxiliary Machinery Capacities
The dimensioning of heat exchangers (coolers)
and pumps for derated engines can be calculated
on the basis of the heat dissipation values found
by using the following description and diagrams.
Those for the nominal MCR (L
1
), may also be used
if wanted.
The nomenclature of the basic engine ratings and
coolers, etc. used in this section is shown in Fig.
6.01.01 and 6.01.02.
Cooler heat dissipations
For the specied MCR (M) the following three dia-
grams in Figs. 6.04.01, 6.04.02 and 6.04.03 show
reduction factors for the corresponding heat dis-
sipations for the coolers, relative to the values
stated in the List of Capacities valid for nominal
MCR (L
1
).
The percentage power (P
M%
) and speed (n
M%
) of L
1

ie: P
M%
= P
M
/P
L1
x 100%
n
M%
= n
M
/n
L1
x 100%
for specied MCR (M) of the derated engine is
used as input in the abovementioned diagrams,
giving the % heat dissipation gures relative to
those in the List of Capacities,
Q
air%
= 100 x (P
M
/P
L1
)
1.68
x (n
M
/n
L1
)
0.83
x k
O
k
O
= 1 + 0.27 x (1 P
O
/P
M
) = 1
178 53 75-3.1
Fig. 6.04.01: Scavenge air cooler, heat dissipation Q
air%
in
point M, in % of the L
1
value Q
air, L1
and valid for P
O
= P
M
..
As matching point O = M, correction k
O
= 1
Q
jw%
= e
( 0.0811 x ln (n
M%
)

+ 0.8072 x ln (P
M%
) + 1.2614)
Fig. 6.04.02: Jacket water cooler, heat dissipation Q
jw%

in point M, in % of the L
1
value Q
jw, L1
178 59 46-9.0
Q
lub%
= 67.3009 x ln (n
M%
) + 7.6304 x ln (P
M%
)
245.0714
Fig. 6.04.03: Lubricating oil cooler, heat dissipation
Q
lub%
in point M, in % of the L
1
value Q
lub, L1
178 53 77-7.1
Specified MCR power, % of L
1
P
M%
110%
100%
90%
80%
70%
60%
80% 85% 90% 95% 105% 100% 110% n
M%
Specified MCR engine speed, % of L
1
L
2
L
4
L
1
L
3
82%
78%
86%
90%
94%
98%
100%
Q
jw%
O=M
Specified MCR power, % of L
1
P
M%
110%
100%
90%
80%
70%
60%
80% 85% 90% 95% 105% 100% 110% n
M%
Specified MCR engine speed, % of L
1
L
2
L
4
L
1
L
3
88%
90%
92%
94%
96%
98%
100%
Q
lub%
M
Specified MCR power, % of L
1
P
M%
110%
100%
90%
80%
70%
60%
80% 85% 90% 95% 105% 100% 110% n
M%
Specified MCR engine speed, % of L
1
L
2
L
4
L
1
L
3
Q
air%
100%
90%
80%
70%
65%
M
MAN B&W 6.04
Page 2 of 12
MAN Diesel
MAN B&W 98-50 ME/ME-C Engine Selection Guide 198 38 65-0.5
Pump pressures
Irrespective of the capacities selected as per the
above guidelines, the belowmentioned pump
heads at the mentioned maximum working tem-
peratures for each system shall be kept:
Pump head
bar
Max. working
temp C
Fuel oil supply pump 4 100
Fuel oil circulating pump 6 150
Lubricating oil pump:
K98ME-C7 4.9 70
K98ME7 4.8 70
K90ME9, S80MEC9,
S90ME-C8
4.7 70
K90ME-C9, S80ME-C8 4.6 70
K80ME-C9, L70ME-C8,
S70ME-C8, S65ME-C8
4.5 70
K80ME-C6 4.4 70
L60ME-C8, S60ME-C8 4.3 70
S50ME-C8 4.1 70
Seawater pump 2.5 50
Central cooling water pump 2.5 80
Jacket water pump 3.0 100

Flow velocities
For external pipe connections, we prescribe the
following maximum velocities:
Marine diesel oil ......................................... 1.0 m/s
Heavy fuel oil .............................................. 0.6 m/s
Lubricating oil ............................................. 1.8 m/s
Cooling water ............................................. 3.0 m/s
MAN B&W 6.04
Page 3 of 12
MAN Diesel
198 73 00-4.0 MAN B&W S70ME-C8-TII
Calculation of List of Capacities for Derated Engine
Example 1:
Pump and cooler capacities for a derated 6S70ME-C8-TII with high efciency MAN Diesel turbocharger
type TCA, xed pitch propeller and central cooling water system.
Nominal MCR, (L
1
) P
L1
: 19,620 kW (100.0%) and 91.0 r/min (100.0%)
Specied MCR, (M) P
M
: 16,677 kW (85.0%) and 81.9 r/min (90.0%)
Matching point, (O) P
O
: 16,677 kW (85.0%) and 81.9 r/min (90.0%), P
O
= 100.0% of P
M
Total cooling water ow through scavenge air
coolers
V
cw,air,M
= V
cw,air,L1
x Q
air%
/ 100

V
cw,air,M
= 283 x 0.831 = 235 m
3
/h
Cooling water ow through lubricating oil cooler
V
cw,lub,M
= V
cw,lub,L1
x Q
lub%
/ 100
V
cw,lub,M
= 212 x 0.917 = 194 m
3
/h
Cooling water ow through central cooler
(Central cooling water pump)
V
cw,cent,M
= V
cw,air,M
+ V
cw,lub,M
V
cw,cent,M
= 235 + 194 = 429 m
3
/h
Cooling water ow through jacket water cooler
(as for lube oil cooler)
V
cw,jw,M
= V
cw,lub,M
V
cw,jw,M
= 194 m
3
/h
Seawater pump for central cooler
As the seawater pump capacity and the central
cooler heat dissipation for the nominal rated en-
gine found in the List of Capacities are 620 m
3
/h
and 12,520 kW the derated seawater pump ow
equals:
Seawater pump:
V
sw,cent,M
= V
sw,cent,L1
x Q
cent,M
/ Q
cent,L1
= 620 x 10,689 / 12,520 = 529 m
3
/h
The method of calculating the reduced capaci-
ties for point M (n
M%
= 90.0% and P
M%
= 85.0%) is
shown below.
The values valid for the nominal rated engine are
found in the List of Capacities, Figs. 6.03.01 and
6.03.02, and are listed together with the result in
the gure on the next page.
Heat dissipation of scavenge air cooler
Fig. 6.04.01 which approximately indicates a Q
air%

= 83.1% heat dissipation, i.e.:
Q
air,M
=Q
air,L1
x Q
air%
/ 100
Q
air,M
= 8,150 x 0.831 = 6,773 kW
Heat dissipation of jacket water cooler
Fig. 6.04.02 indicates a Q
jw%
= 88.5% heat dissi-
pation; i.e.:
Q
jw,M
= Q
jw,L1
x Q
jw%
/ 100
Q
jw,M
= 2,840 x 0.885 = 2,513 kW
Heat dissipation of lube oil cooler
Fig. 6.04.03 indicates a Q
lub%
= 91.7% heat dissi-
pation; i.e.:
Q
lub,M
= Q
lub, L1
x Q
lub%
/ 100
Q
lub,M
= 1,530 x 0.917 = 1,403 kW
Heat dissipation of central water cooler
Q
cent,M
= Q
air,M
+ Q
jw,M
+ Q
lub, M
Q
cent,M
= 6,773 + 2,513 + 1,403 = 10,689 kW
MAN B&W 6.04
Page 4 of 12
MAN Diesel
198 73 00-4.0 MAN B&W S70ME-C8-TII
Nominal rated engine (L
1
)
High efciency
turbocharger (TCA)
Example 1
Specied MCR (M)
Shaft power at MCR 19,620 kW 16,677 kW
Engine speed at MCR at 91.0 r/min at 81.9 r/min
Power of matching point %MCR 100% 90%
Pumps:
Fuel oil circulating pump m
3
/h 7.8 7.8
Fuel oil supply pump m
3
/h 4.9 4.9
Jacket cooling water pump m
3
/h 165 165
Central cooling water pump m
3
/h 495 429
Seawater pump m
3
/h 620 529
Lubricating oil pump m
3
/h 390 390
Coolers:
Scavenge air cooler
Heat dissipation kW 8,150 6,773
Central water quantity m
3
/h 283 235
Lub. oil cooler
Heat dissipation kW 1,530 1,403
Lubricating oil quantity m
3
/h 390 390
Central water quantity m
3
/h 212 194
Jacket water cooler
Heat dissipation kW 2,840 2,513
Jacket cooling water quantity m
3
/h 165 165
Central water quantity m
3
/h 212 194
Central cooler
Heat dissipation kW 12,520 10,689
Central water quantity m
3
/h 495 429
Seawater quantity m
3
/h 620 529
Fuel oil heater: kW 205 205
Gases at ISO ambient conditions*
Exhaust gas amount kg/h 175,800 149,800
Exhaust gas temperature C 245 237.8
Air consumption kg/s 47.9 40.9
Starting air system: 30 bar (gauge)
Reversible engine
Receiver volume (12 starts) m
3
2 x 8.0 2 x 8.0
Compressor capacity, total m
3
/h 480 480
Non-reversible engine
Receiver volume (6 starts) m
3
2 x 4.5 2 x 4.5
Compressor capacity, total m
3
/h 270 270
Exhaust gas tolerances: temperature 15 C and amount 5%
The air consumption and exhaust gas gures are expected and refer to 100% specied MCR,
ISO ambient reference conditions and the exhaust gas back pressure 300 mm WC
The exhaust gas temperatures refer to after turbocharger
* Calculated in example 3, in this chapter
Example 1 Capacities of derated 6S70ME-C8-TII with high efciency MAN Diesel turbocharger type TCA and
central cooling water system.
MAN B&W 6.04
Page 5 of 12
MAN Diesel
MAN B&W K98ME/ME-C-TII, S90ME-C-TII, K90ME/ME-C-TII,
S80ME-C-TII, K80ME-C-TII, S70ME-C/ME-GI-TII, L70ME-C-TII,
S65ME-C/ME-GI-TII, S60ME-C/ME-B/ME-GI-TII,L60ME-C-TII
198 71 45-8.0
Freshwater Generator
If a freshwater generator is installed and is utilis-
ing the heat in the jacket water cooling system,
it should be noted that the actual available heat
in the jacket cooling water system is lower than
indicated by the heat dissipation gures valid for
nominal MCR (L
1
) given in the List of Capacities.
This is because the latter gures are used for
dimensioning the jacket water cooler and hence
incorporate a safety margin which can be needed
when the engine is operating under conditions
such as, e.g. overload. Normally, this margin is
10% at nominal MCR.
Calculation Method
For a derated diesel engine, i.e. an engine having
a specied MCR (M) equal to matching point (O)
different from L
1
, the relative jacket water heat dis-
sipation for point M and O may be found, as previ-
ously described, by means of Fig. 6.04.02.
At part load operation, lower than matching pow-
er, the actual jacket water heat dissipation will be
reduced according to the curves for xed pitch
propeller (FPP) or for constant speed, controllable
pitch propeller (CPP), respectively, in Fig. 6.04.04.
With reference to the above, the heat actually
available for a derated diesel engine may then be
found as follows:
1. Engine power equal to specied power M
(equal to matching point O).
For specied MCR (M) = matching power (O),
the diagram Fig. 6.04.02 is to be used, i.e.
giving the percentage correction factor Q
jw%

and hence for matching power P
O
:
Q
jw,O
= Q
jw,L1
x
Q
jw%

___

100
x 0.9 (0.88) [1]
2. Engine power lower than matching power.

For powers lower than the matching power,
the value Q
jw,O
found for point O by means of
the above equation [1] is to be multiplied by
the correction factor k
p
found in Fig. 6.04.04
and hence
Q
jw
= Q
jw,O
x k
p
15%/0% [2]
where
Part load correction factor for jacket
cooling water heat dissipation
Engine load, % of matching power (O)
FPP : Fixed pitch propeller
CPP : Controllable pitch propeller, constant speed
k
p
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
0 10 20 30 40 50 60 70 80 90 100%
FPP
CPP
178 06 643.2
Fig. 6.04.04: Correction factor kp for jacket cooling
water heat dissipation at part load, relative to heat dis-
sipation at matching power
FPP : k
p
= 0.742 x
P
S

__

P
O
+ 0.258
CPP : k
p
= 0.822 x
P
S

__

P
O
+ 0.178
Q
jw
= jacket water heat dissipation
Q
jw,L1
= jacket water heat dissipation at nominal
MCR (L
1
)
Q
jw%
= percentage correction factor from
Fig. 6.04.02
Q
jw,O
= jacket water heat dissipation at matching
power (O), found by means of equation [1]
k
p
= part load correction factor from Fig. 6.04.04
0.9 = factor for safety margin of cooler, tropical
ambient conditions
The heat dissipation is assumed to be more or less
independent of the ambient temperature conditions,
yet the safety margin/ambient condition factor of
about 0.88 instead of 0.90 will be more accurate for
ambient conditions corresponding to ISO tempera-
tures or lower. The heat dissipation tolerance from
15% to 0% stated above is based on experience.
MAN B&W 6.04
Page 6 of 12
MAN Diesel
MAN B&W K98ME/ME-C-TII, S90ME-C-TII, K90ME/ME-C-TII,
S80ME-C-TII, K80ME-C-TII, S70ME-C/ME-GI-TII, L70ME-C-TII,
S65ME-C/ME-GI-TII, S60ME-C/ME-B/ME-GI-TII,L60ME-C-TII
198 71 45-8.0
Jacket Cooling Water Temperature Control
When using a normal freshwater generator of the
singleeffect vacuum evaporator type, the fresh-
water production may, for guidance, be estimated
as 0.03 t/24h per 1 kW heat, i.e.:
M
fw
= 0.03 x Q
jw
t/24h 15%/0% [3]
where
M
fw
is the freshwater production in tons per 24
hours
and
Q
jw
is to be stated in kW
Valve A: ensures that T
jw
< 85 C
Valve B: ensures that T
jw
> 85 5 C = 80 C
Valve B and the corresponding bypass may be omitted if, for example, the freshwater generator is equipped with an automatic
start/stop function for too low jacket cooling water temperature
If necessary, all the actually available jacket cooling water heat may be utilised provided that a special temperature control system
ensures that the jacket cooling water temperature at the outlet from the engine does not fall below a certain level
Fig. 6.04.05: Freshwater generators. Jacket cooling water heat recovery ow diagram
178 23 700.0
Jacket cooling water system Freshwater generator system
Expansion tank
Jacket cooling
water circuit
min
Tjw
max
Tjw
L
M
K
Seawater
In Out
Condensator
Produced
freshwater
Evaporator
Brine out
B
Jacket water
cooler
Cooling
water
Deaerating tank
Jacket water pumps
Main engine
A
If necessary, all the actually available jacket cool-
ing water heat may be used provided that a special
temperature control system ensures that the jacket
cooling water temperature at the outlet from the
engine does not fall below a certain level. Such a
temperature control system may consist, e.g., of a
special bypass pipe installed in the jacket cooling
water system, see Fig. 6.04.05, or a special builtin
temperature control in the freshwater generator,
e.g., an automatic start/stop function, or similar.
If such a special temperature control is not applied,
we recommend limiting the heat utilised to maxi-
mum 50% of the heat actually available at specied
MCR, and only using the freshwater generator at
engine loads above 50%. Considering the cooler
margin of 10% and the minus tolerance of 15%,
this heat corresponds to 50 x(1.000.15)x0.9 = 38%
of the jacket water cooler capacity Q
jw,M
used for
dimensioning of the jacket water cooler.
MAN B&W 6.04
Page 7 of 12
MAN Diesel
198 73 01-6.0 MAN B&W S70ME-C8-TII
Calculation of Freshwater Production for Derated Engine
Example 2:
Freshwater production from a derated 6S70ME-C8-TII with high efciency MAN Diesel turbocharger type
TCA and xed pitch propeller.
Based on the engine ratings below, this example will show how to calculate the expected available jacket
cooling water heat removed from the diesel engine, together with the corresponding freshwater production
from a freshwater generator.
The calculation is made for the service rating (S) of the diesel engine being 80% of the specied MCR.
Nominal MCR, (L
1
) P
L1
: 19,620 kW (100.0%) and 91.0 r/min (100.0%)
Specied MCR, (M) P
M
: 16,677 kW (85.0%) and 81.9 r/min (90.0%)
Matching point, (O) P
O
: 16,677 kW (85.0%) and 81.9 r/min (90.0%), P
O
= 100.0% of P
M
Service rating, (S) P
S
: 13,342 kW and 76.0 r/min, P
S
= 80.0% of P
M
and P
S
= 80.0% of P
O
Ambient reference conditions: 20 C air and 18 C cooling water.
The expected available jacket cooling water heat
at service rating is found as follows:
Q
jw,L1
= 2,840 kW from List of Capacities
Q
jw%
= 88.5% using 85.0% power and 90.0%
speed for O in Fig. 6.04.02
By means of equation [1], and using factor 0.88 for
actual ambient condition the heat dissipation in
the matching point (O) is found:
Q
jw,O
= Q
jw,L1
x
Q
jw%

___

100
x 0.88
= 2,840 x
88.5

___

100
x 0.88 = 2,212 kW
By means of equation [2], the heat dissipation in
the service point (S) i.e. for 80.0% of matching
power, is found:
k
p
= 0.852 using 80.0% in Fig. 6.04.04
Q
jw
= Q
jw,O
x k
p
= 2,212 x 0.852 = 1,884 kW
15%/0%
For the service point the corresponding expected
obtainable freshwater production from a freshwa-
ter generator of the single effect vacuum evapora-
tor type is then found from equation [3]:
M
fw
= 0.03 x Q
jw
= 0.03 x 1,884 = 56.5 t/24h
15%/0%
MAN B&W 6.04
Page of 12
MAN Diesel
MAN B&W ME-B, ME/MEC, MEGI engines 198 43 181.2
Exhaust Gas Amount and Temperature
Infuencing factors
The exhaust gas data to be expected in practice
depends, primarily, on the following three factors:
a) The specifed MCR point of the engine (point M):
P
M
: power in kW at SMCR point
n
M
: speed in r/min at SMCR point
and to a certain degree on the matching point O
with the percentage power P
O%
= % of SMCR
power:
P
O%
= (P
O
/P
M
) x 100%
b) The ambient conditions, and exhaust gas
backpressure:
T
air
: actual ambient air temperature, in C
p
bar
: actual barometric pressure, in mbar
T
CW
: actual scavenge air coolant temperature,
in C
p
M
: exhaust gas backpressure in mm WC at
specifed MCR
c) The continuous service rating of the engine
(point S), valid for fxed pitch propeller or control-
lable pitch propeller (constant engine speed):
P
S
: continuous service rating of engine, in kW
Calculation Method
To enable the project engineer to estimate the ac-
tual exhaust gas data at an arbitrary service rating,
the following method of calculation may be used.
The partial calculations based on the above infu-
encing factors have been summarised in equations
[4] and [5].
Fig. 6.04.06: Summarising equations for exhaust gas amounts and temperatures
The partial calculations based on the infuencing
factors are described in the following:
a) Correction for choice of specifed MCR point
When choosing a specifed MCR point M other
than the nominal MCR point L
1
, the resulting
changes in specifc exhaust gas amount and
temperature are found by using as input in dia-
grams the corresponding percentage values (of
L
1
) for specifed MCR power P
M%
and speed n
M%
:
P
M%
= P
M
/P
L1
x 100%
n
M%
= n
M
/n
L1
x 100%
M
exh
= M
L1
x
P
M

___

P
L1
x 1 +
m
M%

______

100
x 1 +
M
amb%

_______

100
x 1 +
m
s%

_____

100
x
P
S%

____

100
kg/h +/5% [4]


T
exh
= T
L1
+ T
M
+ T
O
+ T
amb
+ T
S
C /+15 C [5]

where, according to List of capacities, i.e. referring to ISO ambient conditions and 300 mm WC
backpressure and specifed/matched in L
1
:
M
L1
: exhaust gas amount in kg/h at nominal MCR (L
1
)
T
L1
: exhaust gas temperature after turbocharger in C at nominal MCR (L
1
)

M
exh
: exhaust gas amount in kg/h, to be found
T
exh
: exhaust gas temperature in C, to be found
MAN B&W 6.04
Page 9 of 12
MAN Diesel
MAN B&W S90ME-C8, S80ME-C8/9, K80ME-C6,
S70ME-C/ME-GI8, S65ME-C/ME-GI8, S60ME-C/ME-GI8,
L60ME-C7/8, S50ME-C8
198 44 20-9.2
m
M%
: change of specic exhaust gas amount, in
% of specic gas amount at nominal MCR
(L
1
), see Fig. 6.04.07.
T
M
: change in exhaust gas temperature after
turbocharger relative to the L1 value, in C,
see Fig. 6.04.08. (P
O
= P
M
)
T
O
: extra change in exhaust gas temperature
when matching point O lower than 100% M:
P
O%
= (P
O
/P
M
) x 100%.
T
O
= 0.3 x (100 P
O%
) [6]
b) Correction for actual ambient conditions and
backpressure
For ambient conditions other than ISO
3046-1:2002 (E) and ISO 15550:2002 (E), and
backpressure other than 300 mm WC at
specied MCR point (M), the correction fac-
tors stated in the table in Fig. 6.04.09 may
be used as a guide, and the corresponding
relative change in the exhaust gas data may
be found from equations [7] and [8], shown in
Fig. 6.04.10.
Parameter Change
Change of
exhaust gas
temperature
Change of
exhaust gas
amount
Blower inlet temperature + 10 C + 16.0 C 4.1 %
Blower inlet pressure (barometric pressure) + 10 mbar 0.1 C + 0.3 %
Charge air coolant temperature (seawater temperature) + 10 C + 1.0 C + 1.9 %
Exhaust gas back pressure at the specied MCR point + 100 mm WC + 5.0 C 1.1 %
Fig. 6.04.09: Correction of exhaust gas data for ambient conditions and exhaust gas back pressure
m
M%
= 14 x ln (P
M
/P
L1
) 24 x ln (n
M
/n
L1
)
Fig. 6.04.07: Change of specic exhaust gas amount,
m
M%
in % of L
1
value and independent of P
O
T
M
= 15 x ln (P
M
/P
L1
) + 45 x ln (n
M
/n
L1
)
Fig. 6.04.08: Change of exhaust gas temperature, T
M

in point M, in C after turbocharger relative to L
1
value
and valid for P
O
= P
M
178 51 117.2
178 51 130.2
L
4
L
1
L
3
L
2
P
M%
M
110%
100%
90%
80%
70%
80% 85% 90% 95%
M%
Specified MCR engine speed, % of L
1
60%
105% 100% 110% n
Specified MCR power, % of L
1
0 C
T
m
10 C
8 C
6 C
4 C
12 C
2 C
L
2
L
4
L
1
L
3
P
M%
110%
100%
90%
80%
70%
80% 85% 90% 95%
M%
Specified MCR engine speed, % of L
1
60%
105% 100% 110% n
m
M%
M
1%
0%
1%
2%
3%
Specified MCR power, % of L
1
MAN B&W 6.04
Page 10 of 12
MAN Diesel
MAN B&W MC/MCC, ME/ME-B/MEC/MEGI-TII engines 198 71 40-9.0
M
amb%
= 0.41 x (T
air
25) + 0.03 x (p
bar
1000) + 0.19 x (T
CW
25 ) 0.011 x (p
M
300) % [7]
T
amb
= 1.6 x (T
air
25) 0.01 x (p
bar
1000) +0.1 x (T
CW
25) + 0.05 x (p
M
300) C [8]
where the following nomenclature is used:
M
amb%
: change in exhaust gas amount, in % of amount at ISO conditions
T
amb
: change in exhaust gas temperature, in C compared with temperatures at ISO conditions
P
S%
= (P
S
/P
M
) x 100%
m
S%
= 37 x (P
S
/P
M
)
3
87 x (P
S
/P
M
)
2
+ 31 x (P
S
/P
M
) + 19
Fig. 6.04.11: Change of specic exhaust gas amount, m
s%

in % at part load, and valid for FPP and CPP
P
S%
= (P
S
/P
M
) x 100%
T
S
= 280 x (P
S
/P
M
)
2
410 x (P
S
/P
M
) + 130
Fig. 6.04.12: Change of exhaust gas temperature, T
S
in
C at part load, and valid for FPP and CPP
178 24 623.0 178 24 635.0
c) Correction for engine load
Figs. 6.04.11 and 6.04.12 may be used, as
guidance, to determine the relative changes
in the specic exhaust gas data when running
at part load, compared to the values in the
specied MCR point, i.e. using as input P
S%
=
(P
S
/P
M
) x 100%:
m
s%
: change in specic exhaust gas amount,
in % of specic amount at specied MCR
point, see Fig. 6.04.11.
T
s
: change in exhaust gas temperature, in C,
see Fig. 6.04.12.
16
14
20
18
12
10
8
6
4
4
2
2
0
50 60 70 80 90 100 110 P
S%
Engine load, % specified MCR power
m
S%
M
50 60 70 80 90 100 110 P
S%
Engine load, % specified MCR power
M
20
15
10
5
0
-5
-10
-15
-20
-25
T
S
C
Fig. 6.04.10: Exhaust gas correction formula for ambient conditions and exhaust gas back pressure
MAN B&W 6.04
Page 11 of 12
MAN Diesel
MAN B&W S70ME-C8-TII 198 73 02-8.0
Calculation of Exhaust Data for Derated Engine
Example 3:
Expected exhaust gas data for a derated 6S70ME-C8-TII with high efciency MAN Diesel turbocharger
type TCA and xed pitch propeller.
Based on the engine ratings below, and by means of an example, this chapter will show how to calculate
the expected exhaust gas amount and temperature at service rating, and for a given ambient reference
condition different from ISO.
The calculation is made for the service rating (S) being 80% of the specied MCR power of the diesel engine.
Nominal MCR, (L
1
) P
L1
: 19,620 kW (100.0%) and 91.0 r/min (100.0%)
Specied MCR, (M) P
M
: 16,677 kW (85.0%) and 81.9 r/min (90.0%)
Matching point, (O) P
O
: 16,677 kW (85.0%) and 81.9 r/min (90.0%), P
O
= 100.0% of P
M
Service rating, (S) P
S
: 13,342 kW and 76.0 r/min, P
S
= 80.0% of P
M
Reference conditions
Air temperature T
air
........................................ 20 C
Scavenge air coolant temperature T
CW
......... 18 C
Barometric pressure p
bar
....................... 1,013 mbar
Exhaust gas backpressure
at specied MCR p
M
......................... 300 mm WC
a) Correction for choice of specied MCR point M
and matching point O:
P
M%
=
16,677

_____

19,620
x 100 = 85.0%
n
M%
=
81.9

___

91.0
x 100 = 90.0%
By means of Figs. 6.04.07 and 6.04.08:
m
M%
= + 0.25%
T
M
= 7.2 C
As the engine is matched in O lower than 100% M,
and P
O%
= 100.0% of P
M
we get by means of equation [6]
T
O
= 0.3 x (100 100.0) = 0.0 C
b) Correction for ambient conditions and
backpressure:
By means of equations [7] and [8]:
M
amb%
= 0.41 x (20 25) + 0.03 x (1,013 1,000)
+ 0.19 x (18 25) 0.011 x (300 300)%
M
amb%
= + 1.11%
T
amb
= 1.6 x (20 25) 0.01 x (1,013 1,000)
+ 0.1 x (18 25) + 0.05 x (300 300) C
T
amb
= 8.8 C
c) Correction for the engine load:
Service rating = 80% of specied MCR power
By means of Figs. 6.04.11 and 6.04.12:
m
S%
= + 7.1%
T
S
= 18.8 C
MAN B&W 6.04
Page 12 of 12
MAN Diesel
MAN B&W S70ME-C8-TII 198 73 02-8.0
Exhaust gas data at specied MCR (ISO)
At specied MCR (M), the running point may be in
equations [4] and [5] considered as a service point
where P
S%
= 100, m
s%
= 0.0 and T
s
= 0.0.
For ISO ambient reference conditions where
M
amb%
= 0.0 and T
amb
= 0.0, the corresponding
calculations will be as follows:
M
exh,M
= 175,800 x
16,677

_____

19,620
x (1 +
+0.25

____

100
) x (1 +
0.0

___

100
)
x (1 +
0.0

___

100
) x
100.0

____

100
= 149,804 kg/h
M
exh,M
= 149,800 kg/h 5%
T
exh,M
= 245 7.2 0.0 + 0 + 0 = 237.8 C
T
exh,M
= 237.8 C 15 C
The air consumption will be:
149,804 x 0.982 kg/h = 147,107 kg/h <=>
147,107/3,600 kg/s = 40.9 kg/s

Final calculation
By means of equations [4] and [5], the nal result is
found taking the exhaust gas ow M
L1
and tempera-
ture T
L1
from the List of Capacities:
M
L1
= 175,800 kg/h
M
exh
= 175,800 x
16,677

_____

19,620
x (1 +
+0.25

____

100
) x
(1 +
1.11

___

100
) x (1 +
7.1

___

100
) x
80

___

100
= 129,776 kg/h
M
exh
= 129,800 kg/h 5%
The exhaust gas temperature
T
L1
= 245 C
T
exh
= 245 7.2 0.0 8.8 18.8 = 210.2 C
T
exh
= 210.2 C 15 C
MAN B&W
MAN Diesel
Fuel
7
MAN B&W 7.01
Page 1 of 3
MAN Diesel
MAN B&W ME/MEC/MEGI/ME-B engines 198 42 282.7
The system is so arranged that both diesel oil and
heavy fuel oil can be used, see Fig. 7.01.01.
From the service tank the fuel is led to an electri-
cally driven supply pump by means of which a
pressure of approximately 4 bar can be main-
tained in the low pressure part of the fuel circulat-
ing system, thus avoiding gasication of the fuel in
the venting box in the temperature ranges applied.
The venting box is connected to the service tank
via an automatic deaerating valve, which will re-
lease any gases present, but will retain liquids.
From the low pressure part of the fuel system the
fuel oil is led to an electricallydriven circulating
pump, which pumps the fuel oil through a heater
and a full ow lter situated immediately before
the inlet to the engine.
The fuel injection is performed by the electroni-
cally controlled pressure booster located on the
Hydraulic Cylinder Unit (HCU), one per cylinder,
which also contains the actuator for the electronic
exhaust valve activation.
The Cylinder Control Units (CCU) of the Engine
Control System (described in Section 16.01) cal-
culate the timing of the fuel injection and the ex-
haust valve activation.
To ensure ample lling of the HCU, the capacity of
the electricallydriven circulating pump is higher
than the amount of fuel consumed by the diesel
engine. Surplus fuel oil is recirculated from the en-
gine through the venting box.
To ensure a constant fuel pressure to the fuel
injection pumps during all engine loads, a spring
loaded overow valve is inserted in the fuel oil
system on the engine.
The fuel oil pressure measured on the engine (at
fuel pump level) should be 78 bar, equivalent to a
circulating pump pressure of 10 bar.
Fuel considerations
When the engine is stopped, the circulating
pump will continue to circulate heated heavy fuel
through the fuel oil system on the engine, thereby
keeping the fuel pumps heated and the fuel valves
deaerated. This automatic circulation of preheated
fuel during engine standstill is the background
for our recommendation: constant operation on
heavy fuel.
In addition, if this recommendation was not fol-
lowed, there would be a latent risk of diesel oil and
heavy fuels of marginal quality forming incompat-
ible blends during fuel change over or when oper-
ating in areas with restrictions on sulpher content
in fuel oil due to exhaust gas emission control.
In special circumstances a changeover to diesel
oil may become necessary and this can be per-
formed at any time, even when the engine is not
running. Such a changeover may become neces-
sary if, for instance, the vessel is expected to be
inactive for a prolonged period with cold engine
e.g. due to:
docking
stop for more than ve days
major repairs of the fuel system, etc.
The builton overow valves, if any, at the supply
pumps are to be adjusted to 5 bar, whereas the
external bypass valve is adjusted to 4 bar. The
pipes between the tanks and the supply pumps
shall have minimum 50% larger passage area than
the pipe between the supply pump and the circu-
lating pump.
If the fuel oil pipe X at inlet to engine is made as
a straight line immediately at the end of the en-
gine, it will be necessary to mount an expansion
joint. If the connection is made as indicated, with
a bend immediately at the end of the engine, no
expansion joint is required.
Pressurised Fuel Oil System
MAN B&W 7.01
Page 2 of 3
MAN Diesel
198 76 609.1 MAN B&W K98ME/ME-C, S90ME-C, K90ME/ME-C,
S80ME-C, K80ME-C, S70ME-C/ME-GI, L70ME-C,
S65ME-C/ME-GI, S60ME-C/ME-GI/ME-B, L60ME-C
Fuel Oil System
Fig. 7.01.01: Fuel oil system
178 52 197.4
Diesel oil
Heavy fuel oil
Heated pipe with insulation
a) Tracing fuel oil lines: Max.150C
b) Tracing drain lines: By jacket cooling water
The letters refer to the list of Counteranges
Deck
PI TI
Heater
PI TI
From centrifuges
Circulating pumps Supply pumps
D* )
d* )
D* )
32 mm Nominal bore
Aut. deaerating valve
Top of fuel oil service tank
Venting tank
Arr. of main engine fuel oil system.
(See Fig. 7.03.01)
F
X
AF
#
)
a)
a)
BD
To HFO settling tank
AD
b)
To jacket water
cooling pump
To sludge tank
No valve in drain pipe
between engine and tank
Fuel oil
drain tank
overflow tank
If the fuel oil pipe to engine is made as a straight line
immediately before the engine, it will be necessary to
mount an expansion unit. If the connection is made
as indicated, with a bend immediately before the
engine, no expansion unit is required.
Full flow filter.
For filter type see engine spec.
Overflow valve
Adjusted to 4 bar
Heavy fuel oil
service tank
Diesel
oil
service
tank
TE 8005
#) Approximately the following quantity of fuel oil should be treated in
the centrifuges: 0.23 l/kwh as explained in Section 7.05. The capacity of
the centrifuges to be according to manufacturers recommendation.
* ) D to have min. 50% larger passage area than d.
PT 8002
VT 8004
MAN B&W 7.01
Page 3 of 3
MAN Diesel
MAN B&W K98ME/ME-C, S90ME-C, K90ME/ME-C,
S80ME-C, K80ME-C, S70ME-C/ME-GI, L70ME-C,
S65ME-C/ME-GI, S60ME-C/ME-GI/ME-B, L60ME-C
198 76 609.1
Drain of clean fuel oil from HCU, pumps, pipes
The HCU Fuel Oil Pressure Booster has a leakage
drain of clean fuel oil from the umbrella sealing
through AD to the fuel oil drain tank.
The ow rate in litres is approximately as listed in
Table 7.01.01.
Heating of fuel drain pipes
Owing to the relatively high viscosity of the heavy
fuel oil, it is recommended that the drain pipes
and the fuel oil drain tank are heated to min. 50 C,
but max. 100 C.
The drain pipes between engine and tanks can
be heated by the jacket water, as shown in Fig.
7.01.01 Fuel pipe heating as ange BD.
Fuel oil ow velocity and viscosity
For external pipe connections, we prescribe the
following maximum ow velocities:
Marine diesel oil .......................................... 1.0 m/s
Heavy fuel oil ............................................... 0.6 m/s
The fuel viscosity is inuenced by factors such as
emulsication of water into the fuel for reducing
the NO
x
emission. This is further described in Sec-
tion 7.06.
An emulsication arrangement for the main engine
is described in our publication:
Exhaust Gas Emission Control Today and
Tomorrow
Further information about fuel oil specications is
available in our publication:
Guidelines for Fuels and Lubes Purchasing
The publications are available at
www.mandieselturbo.com under Products
Marine Engines & Systems Low Speed
Technical Papers.
Engine
Flow rate,
litres/cyl. h.
K98ME/ME-C, S90ME-C 1.25
K90ME/ME-C, S/K80ME-C, S70ME-C/
ME-C-GI, L70ME-C, S65ME-C/-GI 0.75
S/L60ME-C, S60ME-C-GI 0.60
This drained clean oil will, of course, inuence the
measured SFOC, but the oil is not wasted, and the
quantity is well within the measuring accuracy of
the owmeters normally used.
The main purpose of the drain AF is to collect
pure fuel oil from the fuel pumps as well as the
unintentional leakage from the high pressure
pipes. The drain oil is led to a sludge tank and can
be pumped to the Heavy Fuel Oil service tank or
to the settling tank.
The AF drain is provided with a box for giving
alarm in case of leakage in a high pressure pipe.
The size of the sludge tank is determined on the
basis of the draining intervals, the classication
society rules, and on whether it may be vented
directly to the engine room.
Drains AD and AF are shown in Fig. 7.03.01.
Drain of contaminated fuel etc.
Leakage oil, in shape of fuel and lubricating oil
contaminated with water, dirt etc. and collected
by the HCU Base Plate top plate, is drained off
through the bedplate drains AE.
Drain AE is shown in Fig. 8.07.02.
Table 7.01.01: Approximate ow in HCU leakage drain.
MAN B&W 7.01
Page 2 of 3
MAN Diesel
MAN B&W S50MEC/ME-B, S46ME-B, S40ME-B,
S35ME-B
198 76 610.1
Fuel Oil System
Fig. 7.01.01: Fuel oil system
078 70 06-1.1.0a
Diesel oil
Heavy fuel oil
Heated pipe with insulation
a) Tracing fuel oil lines: Max.150C
b) Tracing drain lines: By jacket cooling water
The letters refer to the list of Counteranges
Deck
PI TI
Heater
PI TI
From centrifuges
Circulating pumps Supply pumps
D* )
d* )
D* )
32 mm Nominal bore
Aut. deaerating valve
Top of fuel oil service tank
Venting tank
Arr. of main engine fuel oil system.
(See Fig. 7.03.01)
F
X
AF
#
)
b)
a)
BD
To storage/settling tank
To freshwater cooling pump suction
To drain tank
Fuel oil
drain tank
If the fuel oil pipe to engine is made as a straight line
immediately before the engine, it will be necessary to
mount an expansion unit. If the connection is made
as indicated, with a bend immediately before the
engine, no expansion unit is required.
Full flow filter.
For filter type see engine spec.
Overflow valve
Adjusted to 4 bar
Heavy fuel oil
service tank
Diesel
oil
service
tank
TE 8005
#) Approximately the following quantity of fuel oil should be treated in
the centrifuges: 0.23 l/kwh as explained in Section 7.05. The capacity of
the centrifuges to be according to manufacturers recommendation.
* ) D to have min. 50% larger passage area than d.
PT 8002
VT 8004
MAN B&W 7.01
Page 3 of 3
MAN Diesel
MAN B&W S50MEC/ME-B, S46ME-B, S40ME-B,
S35ME-B
198 76 610.1
Engine
Flow rate,
litres/cyl. h.
S50ME-C, S50/46/40/35ME-B 0.60
Table 7.01.01: Approximate ow in HCU leakage drain.
Drain of clean fuel oil from HCU, pumps, pipes
The HCU Fuel Oil Pressure Booster has a leakage
drain of clean fuel oil from the umbrella sealing
through AF to the fuel oil drain tank.
The ow rate in litres is approximately as listed in
Table 7.01.01.
This drained clean oil will, of course, inuence the
measured SFOC, but the oil is not wasted, and the
quantity is well within the measuring accuracy of
the owmeters normally used.
The main purpose of the drain AF is to collect
pure fuel oil from the fuel pumps as well as the
unintentional leakage from the high pressure
pipes. From the drain tank, the drained fuel oil is
led to a storage tank or to the settling tank.
The AF drain is provided with a box for giving
alarm in case of leakage in a high pressure pipe.
The size of the sludge tank is determined on the
basis of the draining intervals, the classication
society rules, and on whether it may be vented
directly to the engine room.
Drain AF is shown in Fig. 7.03.01.
Drain of contaminated fuel etc.
Leakage oil, in shape of fuel and lubricating oil
contaminated with water, dirt etc. and collected
by the HCU Base Plate top plate, is drained off
through the bedplate drains AE.
Drain AE is shown in Fig. 8.07.02.
Heating of fuel drain pipes
Owing to the relatively high viscosity of the heavy
fuel oil, it is recommended that the drain pipes
and the fuel oil drain tank are heated to min. 50 C,
but max. 100 C.
The drain pipes between engine and tanks can
be heated by the jacket water, as shown in Fig.
7.01.01 Fuel pipe heating as ange BD.
Fuel oil ow velocity and viscosity
For external pipe connections, we prescribe the
following maximum ow velocities:
Marine diesel oil .......................................... 1.0 m/s
Heavy fuel oil ............................................... 0.6 m/s
The fuel viscosity is inuenced by factors such as
emulsication of water into the fuel for reducing
the NO
x
emission. This is further described in Sec-
tion 7.06.
An emulsication arrangement for the main engine
is described in our publication:
Exhaust Gas Emission Control Today and
Tomorrow
Further information about fuel oil specications is
available in our publication:
Guidelines for Fuels and Lubes Purchasing
The publications are available at
www.mandieselturbo.com under Products
Marine Engines & Systems Low Speed
Technical Papers.
MAN B&W 7.02
Page 1 of 1
MAN Diesel
MAN B&W MC/MC-C, ME/ME-C/ME-GI/ME-B engines 198 38 80-4.5
Fuel Oils
Marine diesel oil:
Marine diesel oil ISO 8217, Class DMB
British Standard 6843, Class DMB
Similar oils may also be used
Heavy fuel oil (HFO)
Most commercially available HFO with a viscosity
below 700 cSt at 50 C (7,000 sec. Redwood I at
100 F) can be used.
For guidance on purchase, reference is made
to ISO 8217:1996 and ISO 8217:2005, British
Standard 6843 and to CIMAC recommendations
regarding requirements for heavy fuel for diesel
engines, fourth edition 2003, in which the maxi-
mum acceptable grades are RMH 700 and RMK
700. The abovementioned ISO and BS standards
supersede BSMA 100 in which the limit was M9.
The data in the above HFO standards and speci-
cations refer to fuel as delivered to the ship, i.e.
before on-board cleaning.
In order to ensure effective and sufcient cleaning
of the HFO, i.e. removal of water and solid con-
taminants, the fuel oil specic gravity at 15 C (60
F) should be below 0.991, unless modern types
of centrifuges with adequate cleaning abilities are
used.
Higher densities can be allowed if special treat-
ment systems are installed.
Current analysis information is not sufcient for
estimating the combustion properties of the oil.
This means that service results depend on oil
properties which cannot be known beforehand.
This especially applies to the tendency of the oil
to form deposits in combustion chambers, gas
passages and turbines. It may, therefore, be nec-
essary to rule out some oils that cause difculties.
Guiding heavy fuel oil specication
Based on our general service experience we have,
as a supplement to the above mentioned stand-
ards, drawn up the guiding HFO specication
shown below.
Heavy fuel oils limited by this specication have,
to the extent of the commercial availability, been
used with satisfactory results on MAN B&W
twostroke low speed diesel engines.
The data refers to the fuel as supplied i.e. before
any on-board cleaning.
Guiding specication (maximum values)
Density at 15 C kg/m
3
< 1.010*
Kinematic viscosity
at 100 C cSt < 55
at 50 C cSt < 700
Flash point C > 60
Pour point C < 30
Carbon residue % (m/m) < 22
Ash % (m/m) < 0.15
Total sediment potential % (m/m) < 0.10
Water % (v/v) < 0.5
Sulphur % (m/m) < 4.5
Vanadium mg/kg < 600
Aluminum + Silicon mg/kg < 80
Equal to ISO 8217:2005 - RMK 700
/ CIMAC recommendation No. 21 - K700
* Provided automatic clariers are installed
m/m = mass v/v = volume
If heavy fuel oils with analysis data exceeding the
above gures are to be used, especially with re-
gard to viscosity and specic gravity, the engine
builder should be contacted for advice regarding
possible fuel oil system changes.
MAN B&W 7.03
Page 1 of 1
MAN Diesel
MAN B&W K98ME/ME-C, S90ME-C, K90ME/ME-C,
K80ME-C
198 39 48-9.4
Fuel Oil Pipes and Drain Pipes
The letters refer to list of Counteranges
The item No. refer to Guidance values automation
126 40 91-7.8.0a
Fig. 7.03.01: Fuel oil and drain pipes
Drain box with
leakage alarm
AF
To sludge tank
Bypass valve
AD
PT 8001 I AL
PI 8001
LS 8006 AH
Local operation panel
Cyl.1
F
X
High pressure pipes
Cyl.1
Fuel cutout system
Only for Germanischer Lloyd
Hydraulic Cylinder Unit
Fuel valve Fuel valve
PI 8001
TI 8005 TE 8005 I
ZV 8020 Z
MAN B&W 7.03
Page 1 of 1
MAN Diesel
MAN B&W S80ME-C, S70ME-C/ME-GI, L70ME-C,
S65ME-C/ME-GI, S60ME-C/ME-GI/ME-B, L60ME-C
198 76 46-7.0
Fuel Oil Pipes and Drain Pipes
The letters refer to list of Counteranges
The item No. refer to Guidance values automation
126 40 91-7.8.0b
Fig. 7.03.01: Fuel oil and drain pipes
Cyl.1
F
X
Drain box with
leakage alarm
AF
To sludge tank
Bypass valve
AD
PT 8001 I AL
PI 8001
LS 8006 AH
Local operation panel
ZV 8020 Z
Fuel valve
Cyl.1
Fuel cutout system
Only for Germanischer Lloyd
High pressure pipes
Hydraulic Cylinder Unit
Fuel valve
PI 8001
TI 8005 TE 8005 I
MAN B&W 7.03
Page 1 of 1
MAN Diesel
MAN B&W S50ME-C 198 76 68-3.0
Fuel Oil Pipes and Drain Pipes
The letters refer to list of Counteranges
The item No. refer to Guidance values automation
317 13 06-6.1.0
Fig. 7.03.01: Fuel oil and drain pipes
Fuel valves
Fore Aft
Leakage alarm
Leakage, high
press. pipes Shock absorber
Baseplate
Counterpressure valve Mixed oil drain
Fuel oil inlet
ELFI pump
Fuel oil outlet
(umbrella)
Fuel oil
return pipe
AF
AE
F
X
To sludge tank
To sludge tank
Clean HFO return to HFO service tank
or settling tank
Checking the condition
of the shock absorber
Baseplate
drain alarm AE
Drain for fuel oil
LS 4112 AH
PI 8001 TI 8005
TE 8005 I PT 8001 I AL
LS 8006 AH
Drain,
pump foot
ZV 8020 Z
Fuel cutout system
Only for Germanischer Lloyd
TE 8005 I
Supplied
with engine Yard supply
(Supplied with engine)
MAN B&W 7.04
Page of 3
MAN Diesel
198 40 518.3 MAN B&W MC/MCC, ME/ME-C/ME-GI/ME-B engines,
Engine Selection Guide
Fuel Oil Pipe Insulation
Flanges and valves
The fanges and valves are to be insulated by
means of removable pads. Flange and valve pads
are made of glass cloth, minimum 400 g/m
2
,
containing mineral wool stuffed to minimum 50
kg/m
3
.
Thickness of the pads to be:
Fuel oil pipes ................................................ 20 mm
Fuel oil pipes and heating pipes together .... 30 mm
The pads are to be ftted so that they lap over the
pipe insulating material by the pad thickness. At
fanged joints, insulating material on pipes should
not be ftted closer than corresponding to the
minimum bolt length.
Mounting
Mounting of the insulation is to be carried out in
accordance with the suppliers instructions.
Insulation of fuel oil pipes and fuel oil drain pipes
should not be carried out until the piping systems
have been subjected to the pressure tests speci-
fed and approved by the respective classifcation
society and/or authorities, Fig. 7.04.0.
The directions mentioned below include insulation
of hot pipes, fanges and valves with a surface
temperature of the complete insulation of maxi-
mum 55 C at a room temperature of maximum 38
C. As for the choice of material and, if required,
approval for the specifc purpose, reference is
made to the respective classifcation society.
Fuel oil pipes
The pipes are to be insulated with 20 mm mineral
wool of minimum 50 kg/m
3
and covered with
glass cloth of minimum 400 g/m
2
.
Fuel oil pipes and heating pipes together
Two or more pipes can be insulated with 30 mm
wired mats of mineral wool of minimum 50 kg/m
3

covered with glass cloth of minimum 400 g/m
2
.
Fig. 7.04.01: Details of fuel oil pipes insulation, option: 4 35 121. Example from 98-50 MC engine
178 50 65 0.2
"E"
Seen from cyl. side
Cyl. 1 Fore
Fuel oil inlet
Heating pipe
Fuel oil outlet
Heating pipe
A-A
B-B
Fuel oil inlet
E
Fuel oil outlet
Drain pipe fuel oil
Cyl. 1 A
A
F X
BF, BX
Fore
B
B
A-A
Funnel and
pipe 8mm
not to be insulated Fuel oil drain
umbrella
AF
AD
BD
MAN B&W 7.04
Page 2 of 3
MAN Diesel
MAN B&W MC/MCC, ME/ME-C/ME-GI/ME-B engines,
Engine Selection Guide
198 40 518.3
Fig. 7.04.02: Heat loss/Pipe cover
I
n
s
u
l
a
t
i
o
n

t
h
i
c
k
n
e
s
s
2
0
3
0
4
0
5
0
6
0
7
0
8
0
9
0
1
0
0
1
2
0
1
6
0
2
0
0
Temperature difference between pipe and room
C
Pipe diameter mm
Heat loss watt/meter pipe
178 50 602.0
Heat Loss in Piping
MAN B&W 7.04
Page 3 of 3
MAN Diesel
198 67 68-4.1 MAN B&W K98MC/MCC, K98ME/ME-C, S90MC-C, S90ME-C,
K90MC-C, K90ME/ME-C, S80MC/MC-C, S80ME-C, K80MC-C,
K80ME-C, S70MC, S/L70MC-C, S/L70ME-C, S70ME-GI, S65ME-GI,
S60MC, S/L60MC-C, S/L60ME-C, S60ME-B, S60ME-GI, S50MC,
Engine Selection Guide
Fuel Oil Pipe Heat Tracing
178 50 625.0
Fig. 7.04.03: Fuel oil pipe heat tracing
The letters refer to list of Counteranges
AF
AD
BD
BX
BF
F
X
Fuel pump
Shock absorber
Fuel valve
Drain cyl. frame
See drawing
Fuel oil pipes insulation
L
Fresh cooling
water outlet
Cyl. 1
The steam tracing of the fuel oil pipes is intended
to operate in two situations:
1. When the circulation pump is running, there
will be a temperature loss in the piping, see
Fig. 7.04.02. This loss is very small, therefore
tracing in this situation is only necessary with
very long fuel supply lines.
2. When the circulation pump is stopped with
heavy fuel oil in the piping and the pipes have
cooled down to engine room temperature, as
it is not possible to pump the heavy fuel oil.
In this situation the fuel oil must be heated to
pumping temperature of about 50 C.
To heat the pipe to pumping level we recom-
mend to use 100 watt leaking/meter pipe.
178 52 555.2
Fig. 7.04.04b: Spray Shields by clamping bands
In order to full IMO regulations, fuel oil and lubri-
cating oil pipe assemblies are to be enclosed by
spray shields as shown in Fig. 7.04.04a and b.
Antisplashing tape Clamping bands
Plate 0,5 mm. thickness
The tape is to be wrapped in accordance with
the makers instruction for class approval
The width is to cover
head of bolts and nuts
Overlap
Fig. 7.04.04a: Spray Shields by anti-splashing tape
To avoid leaks, the spray shields are to be in-
stalled after pressure testing of the pipe system.
Fuel Oil and Lubricating Oil Pipe Spray Shields
MAN B&W 7.04
Page of
MAN Diesel
198 67 69-6.0 MAN B&W S50MC-C7/8, S50ME-C7/8, S46MC-C7/8
Fuel Oil Pipe Heat Tracing
183 15 33-1.2.0a
Fig. 7.04.03: Fuel oil pipe heat tracing
The letters refer to list of Counterfanges
Aft Fore
BX
AF
X
F
BF
BD
From fresh cooling
water outlet
The steam tracing of the fuel oil pipes is intended
to operate in two situations:
1. When the circulation pump is running, there
will be a temperature loss in the piping, see
Fig. 7.04.02. This loss is very small, therefore
tracing in this situation is only necessary with
very long fuel supply lines.
2. When the circulation pump is stopped with
heavy fuel oil in the piping and the pipes have
cooled down to engine room temperature, as
it is not possible to pump the heavy fuel oil.
In this situation the fuel oil must be heated to
pumping temperature of about 50 C.
To heat the pipe to pumping level we recom-
mend to use 100 watt leaking/meter pipe.
178 52 555.2
Fig. 7.04.04b: Spray Shields by clamping bands
In order to fulfl IMO regulations, fuel oil and lubri-
cating oil pipe assemblies are to be enclosed by
spray shields as shown in Fig. 7.04.04a and b.
Anti-splashing tape Clamping bands
Plate 0,5 mm. thickness
The tape is to be wrapped in accordance with
the makers instruction for class approval
The width is to cover
head of bolts and nuts
Overlap
Fig. 7.04.04a: Spray Shields by anti-splashing tape
To avoid leaks, the spray shields are to be in-
stalled after pressure testing of the pipe system.
Fuel Oil and Lubricating Oil Pipe Spray Shields
MAN B&W 7.05
Page 1 of 3
MAN Diesel
MAN B&W MC/MC-C, ME/MEC/MEGI/ME-B engines 198 39 512.6
Components for Fuel Oil System
Fuel oil centrifuges
The manual cleaning type of centrifuges are not to
be recommended, neither for attended machinery
spaces (AMS) nor for unattended machinery spac-
es (UMS). Centrifuges must be selfcleaning, either
with total discharge or with partial discharge.
Distinction must be made between installations for:
Specic gravities < 0.991 (corresponding to ISO
8217 and British Standard 6843 from RMA to
RMH, and CIMAC from A to Hgrades
Specic gravities > 0.991 and (corresponding to
CIMAC Kgrades).
For the latter specic gravities, the manufacturers
have developed special types of centrifuges, e.g.:
Alfa Laval ........................................................ Alcap
Westfalia ....................................................... Unitrol
Mitsubishi .............................................. EHidens II
The centrifuge should be able to treat approxi-
mately the following quantity of oil:
0.23 litres/kWh
This gure includes a margin for:
Water content in fuel oil
Possible sludge, ash and other impurities in the
fuel oil
Increased fuel oil consumption, in connection
with other conditions than ISO standard condi-
tion
Purier service for cleaning and maintenance.
The size of the centrifuge has to be chosen ac-
cording to the suppliers table valid for the select-
ed viscosity of the Heavy Fuel Oil. Normally, two
centrifuges are installed for Heavy Fuel Oil (HFO),
each with adequate capacity to comply with the
above recommendation.
A centrifuge for Marine Diesel Oil (MDO) is not a
must. However, MAN Diesel recommends that at
least one of the HFO puriers can also treat MDO.
If it is decided after all to install an individual puri-
er for MDO on board, the capacity should be
based on the above recommendation, or it should
be a centrifuge of the same size as that for HFO.
The Nominal MCR is used to determine the to-
tal installed capacity. Any derating can be taken
into consideration in borderline cases where the
centrifuge that is one step smaller is able to cover
Specied MCR.
Fuel oil supply pump
This is to be of the screw or gear wheel type.
Fuel oil viscosity, specied .... up to 700 cSt at 50 C
Fuel oil viscosity maximum .......................1000 cSt
Pump head ......................................................4 bar
Fuel oil ow ........................ see List of Capacities
Delivery pressure ............................................4 bar
Working temperature ................................... 100 C
Minimum temperature .................................... 50 C
The capacity stated in List of Capacities is to be ful-
lled with a tolerance of: 0% to +15% and shall also
be able to cover the backushing, see Fuel oil lter.
Fuel oil circulating pump
This is to be of the screw or gear wheel type.
Fuel oil viscosity, specied .... up to 700 cSt at 50 C
Fuel oil viscosity normal ................................20 cSt
Fuel oil viscosity maximum .......................1000 cSt
Fuel oil ow ........................ see List of Capacities
Pump head ......................................................6 bar
Delivery pressure .......................................... 10 bar
Working temperature ................................... 150 C
The capacity stated in List of Capacities is to be ful-
lled with a tolerance of: 0% to +15% and shall also
be able to cover the backushing, see Fuel oil lter.
Pump head is based on a total pressure drop in
lter and preheater of maximum 1.5 bar.
MAN B&W 7.05
Page 2 of 3
MAN Diesel
MAN B&W MC/MC-C, ME/MEC/MEGI/ME-B engines 198 39 512.6
The heater is to be of the tube or plate heat ex-
changer type.
The required heating temperature for different oil
viscosities will appear from the Fuel oil heating
chart, Fig. 7.05.01. The chart is based on informa-
tion from oil suppliers regarding typical marine
fuels with viscosity index 7080.
Since the viscosity after the heater is the control-
led parameter, the heating temperature may vary,
depending on the viscosity and viscosity index of
the fuel.
Recommended viscosity meter setting is 1015 cSt.
Fig. 7.05.01: Fuel oil heating chart
Fuel oil viscosity specied ... up to 700 cSt at 50C
Fuel oil ow .................................... see capacity of
fuel oil circulating pump
Heat dissipation ................. see List of Capacities
Pressure drop on fuel oil side ........maximum 1 bar
Working pressure .......................................... 10 bar
Fuel oil inlet temperature .................approx. 100 C
Fuel oil outlet temperature ........................... 150 C
Steam supply, saturated .......................... 7 bar abs
To maintain a correct and constant viscosity of
the fuel oil at the inlet to the main engine, the
steam supply shall be automatically controlled,
usually based on a pneumatic or an electrically
controlled system.
Temperature
after heater
C
170
160
150
140
130
120
110
100
90
80
70
60
50
40
30
Normal heating limit
Approximate pumping limit
10 15 25 35 45 55 cST/100C
200 400 800 1500 3500 6000 sec.Rw/100 F
30 100 180 380 600 cST/50C
Approximate viscosity
after heater
cSt.
sec.
Rw.
7
10
12
15
20
30
43
52
59
69
87
125
60
178 06 280.1
Fuel Oil Heater
MAN B&W 7.05
Page of
MAN Diesel
MAN B&W MC/MC-C, ME/ME-C/ME-GI/ME-B engines,
MC/ME Engine selection guides
198 47 35-0.2
Fuel oil flter
The flter can be of the manually cleaned duplex
type or an automatic flter with a manually cleaned
bypass flter.
If a double flter (duplex) is installed, it should
have suffcient capacity to allow the specifed full
amount of oil to fow through each side of the flter
at a given working temperature with a max. 0.
bar pressure drop across the flter (clean flter).
If a flter with backfushing arrangement is
installed, the following should be noted. The re-
quired oil fow specifed in the List of capacities,
i.e. the delivery rate of the fuel oil supply pump and
the fuel oil circulating pump, should be increased
by the amount of oil used for the backfushing, so
that the fuel oil pressure at the inlet to the main en-
gine can be maintained during cleaning.
In those cases where an automatically cleaned
flter is installed, it should be noted that in order
to activate the cleaning process, certain makers of
flters require a greater oil pressure at the inlet to
the flter than the pump pressure specifed. There-
fore, the pump capacity should be adequate for
this purpose, too.
The fuel oil flter should be based on heavy fuel oil
of: 10 cSt at 80 C = 700 cSt at 50 C = 7000 sec
Redwood I/100 F.
Fuel oil fow ......................... see List of capacities
Working pressure .......................................... 10 bar
Test pressure ...................... according to class rule
Absolute fneness .......................................... 50 m
Working temperature .................. maximum 150 C
Oil viscosity at working temperature ............15 cSt
Pressure drop at clean flter ........maximum 0. bar
Filter to be cleaned at a pressure
drop of ........................................maximum 0.5 bar
Note:
Absolute fneness corresponds to a nominal fne-
ness of approximately 35 m at a retaining rate of
90%.
The flter housing shall be ftted with a steam jack-
et for heat tracing.
H
4
H
1
H
2
H
3
H
5
2
0
0
Top of fuel oil
service tank
60
vent pipe,
nominal: D3
Cone
lnlet pipe,
nominal: D2
Pipe,
nominal: D1
Outlet pipe,
nominal: D2
Fuel oil venting box
The design of the Fuel oil venting box is shown in
Fig. 7.05.02. The size is chosen according to the
maximum fow of the fuel oil circulation pump,
which is listed in section 6.0.
178 38 393.3
Flushing of the fuel oil system
Before starting the engine for the frst time, the
system on board has to be fushed in accordance
with MAN Diesels recommendations Flushing of
Fuel Oil System which is available on request.
Flow m
3
/h
Q (max.)*
Dimensions in mm
D1 D2 D H1 H2 H H4 H5
1. 150 2 15 100 600 171. 1,000 550
2.1 150 40 15 100 600 171. 1,000 550
5.0 200 65 15 100 600 171. 1,000 550
8.4 400 80 15 150 1,200 .5 1,800 1,100
11.5 400 90 15 150 1,200 .5 1,800 1,100
19.5 400 125 15 150 1,200 .5 1,800 1,100
29.4 500 150 15 150 1,500 402.4 2,150 1,50
4.0 500 200 15 150 1,500 402.4 2,150 1,50
* The maximum fow of the fuel oil circulation pump
Fig. 07.05.02: Fuel oil venting box
MAN B&W 7.06
Page 1 of 2
MAN Diesel
MAN B&W MC/MC-C, ME/ME-C/MEB/GI engines 198 38 828.4
The emulsication of water into the fuel oil reduc-
es the NO
x
emission with about 1% per 1% water
added to the fuel up to about 20% without modi-
cation of the engine fuel injection equipment.
A Water In Fuel emulsion (WIF) mixed for this pur-
pose and based on Heavy Fuel Oil (HFO) is stable
for a long time, whereas a WIF based on Marine
Diesel Oil is only stable for a short period of time
unless an emulsifying agent is applied.
As both the MAN B&W twostroke main engine
and the MAN Diesel GenSets are designed to run
on emulsied HFO, it can be used for a common
system.
It is supposed below, that both the main engine
and GenSets are running on the same fuel, either
HFO or a homogenised HFO-based WIF.
Special arrangements are available on request for
a more sophisticated system in which the GenSets
can run with or without a homogenised HFO-
based WIF, if the main engine is running on that.
Please note that the fuel pump injection capacity
shall be conrmed for the main engine as well as
the GenSets for the selected percentage of water
in the WIF.
Temperature and pressure
When water is added by emulsication, the fuel
viscosity increases. In order to keep the injection
viscosity at 10-15 cSt and still be able to operate
on up to 700 cSt fuel oil, the heating temperature
has to be increased to about 170 C depending on
the water content.
The higher temperature calls for a higher pressure
to prevent cavitation and steam formation in the
system. The inlet pressure is thus set to 13 bar.
In order to avoid temperature chock when mixing
water into the fuel in the homogeniser, the water
inlet temperature is to be set to 7090 C.
Safety system
In case the pressure in the fuel oil line drops, the
water homogenised into the Water In Fuel emul-
sion will evaporate, damaging the emulsion and
creating supply problems. This situation is avoid-
ed by installing a third, air driven supply pump,
which keeps the pressure as long as air is left in
the tank S, see Fig. 7.06.01.
Before the tank S is empty, an alarm is given and
the drain valve is opened, which will drain off the
WIF and replace it with HFO or diesel oil from the
service tank.
The drain system is kept at atmospheric pressure,
so the water will evaporate when the hot emulsion
enters the safety tank. The safety tank shall be
designed accordingly.
Impact on the auxiliary systems
Please note that if the engine operates on Water
In Fuel emulsion (WIF), in order to reduce the NO
x

emission, the exhaust gas temperature will de-
crease due to the reduced air / exhaust gas ratio
and the increased specic heat of the exhaust gas.
Depending on the water content, this will have an
impact on the calculation and design of the fol-
lowing items:
Freshwater generators
Energy for production of freshwater
Jacket water system
Waste heat recovery system
Exhaust gas boiler
Storage tank for freshwater
For further information about emulsication of wa-
ter into the fuel and use of Water In Fuel emulsion
(WIF), please refer to our publication titled:
Exhaust Gas Emission Control Today and
Tomorrow
The publication is available at
www.mandieselturbo.com under Products
Marine Engines & Systems Low Speed
Technical Papers.
Water In Fuel Emulsication
MAN B&W 7.06
Page 2 of 2
MAN Diesel
MAN B&W MC/MC-C, ME/ME-C/MEB/GI engines 198 38 828.4
Diesel oil
Heavy fuel oil
Heated pipe with insulation
a) Tracing fuel oil lines: Max. 150 C
b) Tracing fuel oil drain lines: Max. 90 C,
min. 50 C for installations with jacket cooling water
Number of auxiliary engines, pumps, coolers, etc.
are subject to alterations according to the actual
plant specication.
The letters refer to the list of Counteranges.
Fig. 7.06.01: System for emulsication of water into the fuel common to the main engine and MAN Diesel GenSets
198 99 018.3
From
centrifuges
Deck
Diesel
oil service
tank
Heavy fuel oil
service tank
Overflow valve
adjusted to
12 bar
Supply pumps
Filter
Booster
pump
Compressed
air
S
Safety pump
air operated
Fresh water
supply
To special
safety tank
Automatic
deaerating
valve
Venting box
Common fuel oil supply unit
Homogeniser
Full flow
filter
Water in oil
measuring
Circulating
pumps
Heater
BX F
BF
X
AD
AF BD
b)
a)
32 mm
Nom.
bore
Main engine
F.O.
drain
tank
To HFO service
or settling tank
A2
A1
A3
GenSet
A2
A1
A3
GenSet
A2
A1
A3
GenSet
To HFO service
or settling tank
Fuel oil
sludge tank
To freshwater cooling
pump suction
F. O. special
safety tank
Deaerating to be
controlled against
expansion of water
To HFO
service or
settling tank
Supply air tank
MAN B&W
MAN Diesel
Lubricating Oil

8
MAN B&W 8.01
Page 1 of 1
MAN Diesel
MAN B&W ME/MEC/MEGI engines 198 42 304.3
Lubricating and Cooling Oil System
Thermostatic valve
TI TI TI
Lube. oil
cooler
For initial fillling of pumps
Pos. 006: 25 mm valve
for cleaning process
Lube oil pumps
Engine
oil
PI PI
Fullflow filter
RU
AR
E
AB
Min. 15
Lube oil bottom tank
with cofferdam
To purifier From purifier
Deck
To drain tank
Pos. 005: throttle valve
Deaeration
Feeler, 45 C
*
S S
Servo oil backflushing
see Section 8.08
RW
The letters refer to list of Counteranges
* Venting for MAN Diesel or Mitsubishi turbochargers only
198 99 844.5
The lubricating oil is pumped from a bottom tank
by means of the main lubricating oil pump to the
lubricating oil cooler, a thermostatic valve and,
through a fullow lter, to the engine inlet RU, Fig.
8.01.01.
RU lubricates main bearings, thrust bearing, axial
vibration damper, piston cooling, crosshead bear-
ings, crankpin bearings. It also supplies oil to the
Hydraulic Power Supply unit and to moment com-
pensator and torsional vibration damper.
From the engine, the oil collects in the oil pan,
from where it is drained off to the bottom tank,
see Fig. 8.06.01a and b Lubricating oil tank, with
cofferdam. By class demand, a cofferdam must
be placed underneath the lubricating oil tank.
The engine crankcase is vented through AR by a
pipe which extends directly to the deck. This pipe
has a drain arrangement so that oil condensed in
the pipe can be led to a drain tank, see details in
Fig. 8.07.01.
Drains from the engine bedplate AE are tted on
both sides, see Fig. 8.07.02 Bedplate drain pipes.
For external pipe connections, we prescribe a
maximum oil velocity of 1.8 m/s.
Lubrication of turbochargers
Turbochargers with slide bearings are normally
lubricated from the main engine system. AB is
outlet from the turbocharger, see Figs. 8.03.01 to
8.03.04, which are shown with sensors for UMS.
Figs. 8.03.01 to 8.03.04 show the lube oil pipe ar-
rangements for different turbocharger makes.
Fig. 8.01.01 Lubricating and cooling oil system
MAN B&W 8.02
Page of 2
MAN Diesel
MAN B&W ME/ME-C/ME-GI engines 198 42 31-6.1
Hydraulic Power Supply Unit
Internally on the engine RU is connected to the
Hydraulic Power Supply unit (HPS) which supplies
the hydraulic oil to the Hydraulic Cylinder Units
(HCUs). The HPS unit can be either mounted onto
the engine and engine driven (EoD 4 40 60) or
delivered separately electrically driven, option 4
40 660. See fgs. 6.0.02 and 6.0.03 respec-
tively.
The hydraulic power supply unit shown in Fig.
8.02.0, consists of:
an automatic main flter with a redundance flter,
in parallel
two electrically driven pumps
three engine driven pumps
an safety and accumulator block
RW is the oil outlet from the automatic backfush-
ing flter.
At start one of the two electrically driven startup
pumps is activated, and it is stopped as soon as
the three engine driven pumps have taken over
the hydraulic oil supply.
The hydraulic oil is supplied to the Hydraulic Cyl-
inder Units (HCU) located at each cylinder, where
it is diverted to the electronic Fuel Injection sys-
tem, and to the electronic exhaust Valve Activa-
tion (FIVA) system, which perform the fuel injec-
tion and opens the exhaust valve. The exhaust
valve is closed by the conventional air spring.
The electronic signals to the FIVA valves are given
by the Engine Control System, see Chapter 6,
Engine Control System (ECS).
The Hydraulic power supply is available
in 2 versions
The standard version, EoD 4 40 660, is the clas-
sic ME power supply where the hydraulic power
is generated by engine driven pumps and start up
pressure is created by electric driven start pumps.
The capacity of the start up pumps is only suf-
fcient to make the start up pressure. The engine
can not run with the engine driven pumps out of
operation.
The optional version, EoD 4 40 66 is similar to
the standard version, but the electric driven start
up pumps have a capacity suffcient to give Take
Home power at least 5% engine power. The
electric power consumption should be taken into
consideration in the specifcation of the auxilliary
machinery capacity.
MAN B&W 8.02
Page 2 of 2
MAN Diesel
MAN B&W ME/ME-C/ME-GI engines 198 42 31-6.1
S
a
f
e
t
y

a
n
d

a
c
c
u
m
u
l
a
t
o
r

b
l
o
c
k
H
y
d
r
a
u
l
i
c

P
o
w
e
r

S
u
p
p
l
y

u
n
i
t
E
n
g
i
n
e
d
r
i
v
e
n
p
u
m
p
s
E
l
e
c
t
r
i
c
a
l
l
y

d
r
i
v
e
n
p
u
m
p
s
H
y
d
r
a
u
l
i
c

o
i
l
M
M
F
i
l
t
e
r

u
n
i
t
A
u
t
o
m
a
t
i
c
b
y
-
p
a
s
s
v
a
l
v
e
R
e
d
u
n
d
a
n
c
e

f
i
l
t
e
r
M
a
i
n

f
i
l
t
e
r
B
a
c
k
-
f
l
u
s
h
i
n
g

o
i
l
R
W
R
U
L
u
b
e

o
i
l

t
o

t
u
r
b
o
c
h
a
r
g
e
r T
o

h
y
d
r
a
u
l
i
c
c
y
l
i
n
d
e
r

u
n
i
t
C
r
o
s
s
h
e
a
d

b
e
a
r
i
n
g
s

&

p
i
s
t
o
n
M
a
i
n

b
e
a
r
i
n
g
s
S
y
s
t
e
m

o
i
l

o
u
t
l
e
t
A
x
i
a
l

v
i
b
r
a
t
i
o
n

d
a
m
p
e
r
S
A
R
A
f
t
F
o
r
e
P
I


8
1
0
8
P
I


8
1
0
8



I



A
L


Y
P
I


8
1
0
8



Z
W
T


8
8
1
2


I



A
H


Y
W
I


8
8
1
2
L
S


1
2
3
4


A
H
F
S


8
1
1
4



A
L



Y
T
I



8
1
1
3
T
I


8
1
1
3



i


A
H
T
E


8
1
0
6


I



A
H


Y
T
I


8
1
0
6
T
E


8
1
0
6


Z
T
E


8
1
0
6


I



A
H
L
S


1
2
3
6


A
H

Z
T
I



8
1
1
2
L
S


1
2
3
5


A
H
The letters refer to List of fanges
The pos. numbers refer to List of instruments
The piping is delivered with and ftted onto the engine
Fig. 8.02.01: Engine driven hydraulic power supply unit
Hydraulic power supply unit, Engine Driven
178 48 134.1
MAN B&W 8.03
Page 1 of 2
MAN Diesel
MAN B&W MC/MCC, ME/MEC/MEGI/ME-B engines,
Engine Selection Guide
198 42 328.3
Lubricating Oil Pipes for Turbochargers
From system oil
MAN Diesel TCA
turbocharger
AB
TE 8117 I AH
TI 8117
PI 8103
PT 8103 I AL
E
Fig. 8.03.01: MAN Diesel turbocharger type TCA
121 14 96-6.1.0
From system oil
ABB TPL
turbocharger
AB
TE 8117 I AH
TI 8117
PI 8103
PT 8103 I AL
Fig. 8.03.02: ABB turbocharger type TPL
126 40 85-8.3.0
MAN B&W 8.03
Page 2 of 2
MAN Diesel
MAN B&W MC/MCC, ME/MEC/MEGI/ME-B engines,
Engine Selection Guide
198 42 328.3
From system oil
MET turbocharger
AB
E
TE 8117 I AH
TI 8117
PI 8103
Fig. 8.03.03: Mitsubishi turbocharger type MET
126 40 87-1.2.0
MAN B&W 8.04
Page 1 of 1
MAN Diesel
MAN B&W MC/MC-C, ME/MEC/MEGI/ME-B engines,
Engine Selection Guide
198 38 865.6
Lubricating Oil Centrifuges and List of Lubricating Oils
For Unattended Machinery Spaces (UMS), auto-
matic centrifuges with total discharge or partial
discharge are to be used. Manual cleaning cen-
trifuges can only be used for Attended Machinery
Spaces (AMS).
The nominal capacity of the centrifuge is to be
according to the suppliers recommendation for
lubricating oil, based on the gure:
0.136 litre/kWh
The Nominal MCR is used as the total installed
power.
List of lubricating oils
The circulating oil (lubricating and cooling oil)
must be of the rust and oxidation inhibited type of
oil of SAE 30 viscosity grade.
In order to keep the crankcase and piston cooling
spaces clean of deposits, the oil should have ad-
equate dispersion and detergent properties.
Alkaline circulating oils are generally superior in
this respect.
The oils listed below have all given long-term sat-
isfactory service in MAN B&W engine installations:
Company
Circulating oil
SAE 30, BN 510
BP Energol OEHT 30
Castrol CDX 30
Chevron *) Veritas 800 Marine 30
ExxonMobil Mobilgard 300
Shell Melina 30 / S 30
Total Atlanta Marine D 3005
*) Includes Caltex, Chevron and Texaco
Also other brands have been used with satisfac-
tory results.
MAN B&W 8.05
Page 1 of 1
MAN Diesel
MAN B&W MC/MC-C, ME/ME-C/-GI, ME-B engines 198 38 87-7.4
Lubricating oil full ow lter
Lubricating oil ow .............. see List of capacities
Test pressure .....................according to class rules
Working temperature ............. approximately 45 C
Oil viscosity at working temp .............. 90 100 cSt
Pressure drop with clean lter ....maximum 0.2 bar
Filter to be cleaned
at a pressure drop .......................maximum 0.5 bar
The lter working pressure and absolute neness
is to be found in the Project Guide for the specic
engine.
Note:
8590% of all particles bigger than 25 m are
retained in surface lter with a lter neness of 40
m absolute, and 35 m for 50 m.
The ow capacity must be within a range from
100 to 112% of the capacity stated.
The full ow lter should be located as close as
possible to the main engine.
If a double lter (duplex) is installed, it should
have sufcient capacity to allow the specied full
amount of oil to ow through each side of the lter
at a given working temperature with a pressure
drop across the lter of maximum 0.2 bar (clean
lter).
If a lter with a backushing arrangement is in-
stalled, the following should be noted:
The required oil ow, specied in the List of
capacities, should be increased by the a mount
of oil used for the backushing, so that the
lubricating oil pressure at the inlet to the main
engine can be maintained during clean ing.
If an automatically cleaned lter is installed, it
should be noted that in order to activate the
cleaning process, certain makes of lter require
a higher oil pressure at the inlet to the lter than
the pump pressure specied. There fore, the
pump capacity should be adequate for this pur-
pose, too.
Flushing of lubricating oil system
Before starting the engine for the rst time, the lu-
bricating oil system on board has to be cleaned in
accordance with MAN Diesels recommendations:
Flushing of Main Lubricating Oil System, which is
available on request.
Components for Lubricating Oil System
MAN B&W 8.06
Page 1 of 1
MAN Diesel
198 48 559.1 MAN B&W MC/ME Engine Selection Guide
Lubricating Oil Tank
Please note that the information is to be found in
the Project Guide for the relevant engine type.
MAN B&W 8.07
Page 1 of 1
MAN Diesel
198 48 560.1 MAN B&W MC/ME Engine Selection Guide
Crankcase Venting and Bedplate Drain Pipes
Please note that the information is to be found in
the Project Guide for the relevant engine type.
MAN B&W 8.08
Page 1 of 1
MAN Diesel
MAN B&W ME/MEC/MEGI/ME-B engines
ME Engine Selection Guide
198 48 297.3
Hydraulic Oil Backushing
The special suction arrangement for purier suc-
tion in connection with the ME engine (Integrated
system).
The back-ushing oil from the self cleaning 6 m
hydraulic control oil lter unit built onto the engine
is contaminated and it is therefore not expedient to
lead it directly into the lubricating oil sump tank.
The amount of back-ushed oil is large, and it
is considered to be too expensive to discard
it. Therefore, we suggest that the lubricating
oil sump tank is modied for the ME engines in
order not to have this contaminated lubricating
hydraulic control oil mixed up in the total amount
of lubricating oil. The lubricating oil sump tank is
designed with a small back-ushing hydraulic
control oil drain tank to which the back-ushed
hydraulic control oil is led and from which the lu-
bricating oil purier can also suck.
This is explained in detail below and the principle
is shown in Fig. 8.08.01. Three suggestions for the
arrangement of the drain tank in the sump tank
are shown in Fig. 8.08.02 illustrates another sug-
gestion for a back-ushing oil drain tank.
The special suction arrangement for the purier is
consisting of two connected tanks (lubricating oil
sump tank and back-ushing oil drain tank) and
of this reason the oil level will be the same in both
tanks, as explained in detail below.
The oil level in the two tanks will be equalizing
through the branch pipe to back-ushing oil drain
tank, see Fig. 8.08.01. As the pipes have the
same diameters but a different length, the resis-
tance is larger in the branch pipe to back-ushing
oil drain tank, and therefore the purier will suck
primarily from the sump tank.
The oil level in the sump tank and the back-ush-
ing oil drain tank will remain to be about equal be-
cause the tanks are interconnected at the top.
When hydraulic control oil is back-ushed from
the lter, it will give a higher oil level in the back-
ushing hydraulic control oil drain tank and the
purier will suck from this tank until the oil level is
the same in both tanks. After that, the purier will
suck from the sump tank, as mentioned above.
Fig. 8.08.01: Backushing servo oil drain tank
178 52 518.2
Fig. 8.08.02: Alternative design for the
backushing servo oil drain tank
178 52 496.2
This special arrangement for purier suction will
ensure that a good cleaning effect on the lubrica-
tion oil is obtained.
If found protable the back-ushed lubricating oil
from the main lubricating oil lter (normally a 50 or
40 m lter) can also be returned into the special
back-ushing oil drain tank.
Oil level
5
0
D
/
3
D
8
X

5
0
D
/
3
D
Purifier
suction pipe
Lubricating
oil tank top
Venting
holes
Backflushed hydraulic
control oil from self
cleaning 6 m filter
Branch pipe to
backflushing
hydraulic control
oil drain tank
Sump
tank
Backflushing
hydraulic control
oil drain tank
Pipe 400
or 400
Lubricating
oil tank bottom
Oil level
Support
Venting holes
D D
D
/
3
D
/
3
Purifier
suction pipe
Lubricating
oil tank top
Backflushed hydraulic
controloil from self
cleaning 6 m filter
Sump
tank
Backflushing
hydraulic control
oil drain tank
Lubricating oil tank bottom
MAN B&W 8.09
Page of 4
MAN Diesel
MAN B&W ME/ME-C/ME-GI engines 198 48 523.2
Separate System for Hydraulic Control Unit
As an option, the engine can be prepared for the
use of a separate hydraulic control oil system
Fig. 8.09.0.
The separate hydraulic control oil system can be
built as a unit, or be built streamlined in the engine
room with the various components placed and
fastened to the steel structure of the engine room.
The design and the dimensioning of the various
components are based on the aim of having a reli-
able system that is able to supply lowpressure oil
to the inlet of the enginemounted highpressure
hydraulic control oil pumps at a constant pres-
sure, both at engine standby and at various en-
gine loads. The quality of the hydraulic control oil
must fulfl the same grade as for our standard in-
tegrated lube/cooling/hydrauliccontrol oil system,
i.e. ISO 4406 XX/6/3 equivalent to NAS 638
Class 7.
The hydraulic control oil system comprises:
Hydraulic control oil tank
2 Hydraulic control oil pumps (one for standby)
Pressure control valve
Hydraulic control oil cooler, watercooled by the
low temperature cooling water
Threeway valve, temperature controlled
Hydraulic control oil flter, duplex type or auto-
matic selfcleaning type
Hydraulic control oil fne flter with pump
Temperature indicator
Pressure indicator
2 Level alarms
Valves and cocks
Piping.
Hydraulic control oil tank
The tank can be made of mild steel plate or be a
part of the ship structure.
The tank is to be equipped with fange connec-
tions and the items listed below:
Oil flling pipe
Outlet pipe for pump suctions
Return pipe from engine
Drain pipe
Vent pipe.
The hydraulic control oil tank is to be placed at
least m below the hydraulic oil outlet fange, RZ.
Hydraulic control oil pump
The pump must be of the displacement type (e.g.
gear wheel or screw wheel pump).
The following data is specifed in Fig. 8.09.02:
Pump capacity
Pump head
Delivery pressure
Working temperature
Oil viscosity range.
Pressure control valve
The valve is to be of the selfoperating fow control-
ling type, which bases the fow on the predefned
pressure set point. The valve must be able to react
quickly from the fullyclosed to the fullyopen posi-
tion (t
max
= 4 sec), and the capacity must be the
same as for the hydraulic control oil lowpressure
pumps. The set point of the valve has to be within
the adjustable range specifed on a separate
drawing.
The following data is specifed in Fig. 8.09.02:
Flow rate
Adjustable differential pressure range across
the valve
Oil viscosity range.
Hydraulic control oil cooler
The cooler must be of the plate heat exchanger or
shell and tube type.
The following data is specifed in Fig. 8.09.02:
Heat dissipation
Oil fow rate
Oil outlet temperature
Maximum oil pressure drop across the cooler
Cooling water fow rate
Water inlet temperature
Maximum water pressure drop across the cooler.
Temperature controlled threeway valve
The valve must act as a control valve, with an ex-
ternal sensor.
The following data is specifed in Fig. 8.09.02:
Capacity
Adjustable temperature range
Maximum pressure drop across the valve.
MAN B&W 8.09
Page 2 of 4
MAN Diesel
MAN B&W ME/ME-C/ME-GI engines 198 48 523.2
Hydraulic control oil flter
The flter is to be of the duplex full fow type with
manual change over and manual cleaning or of
the automatic self cleaning type.
A differential pressure gauge is ftted onto the
flter
The following data is specifed in Fig. 8.09.02:
Filter capacity
Maximum pressure drop across the flter
Filter mesh size (absolute)
Oil viscosity
Design temperature.
Off-line hydraulic control oil fne flter or purifer
Fig. 8.09.0
The off-line fne flter unit or purifer must be able
to treat 5-20% of the total oil volume per hour.
The fne flter is an off-line flter and removes me-
tallic and non-metallic particles larger than 0,8
m as well as water and oxidation. The flter has a
pertaining pump and is to be ftted on the top of
the hydraulic control oil tank.
A suitable fne flter unit is:
Make: CJC, C.C. Jensen A/S, Svendborg,
Denmark - www.cjc.dk.
For oil volume <0,000 litres:
HDU 27/-MZ-Z with a pump fow of 5-20% of the
total oil volume per hour.
For oil volume >0,000 litres:
HDU 27/-GP-DZ with a pump fow of 5-20% of
the total oil volume per hour.
Temperature indicator
The temperature indicator is to be of the liquid
straight type.
Pressure indicator
The pressure indicator is to be of the dial type.
Level alarm
The hydraulic control oil tank has to have level
alarms for high and low oil level.
Piping
The pipes can be made of mild steel.
The design oil pressure is to be 0 bar.
The return pipes are to be placed vertical or laid
with a downwards inclination of minimum 5.
MAN B&W 8.09
Page 3 of 4
MAN Diesel
MAN B&W ME/ME-C/ME-GI engines 198 48 523.2
Oil Cooler
vent Pipe
Oil Tank Manhole
1303 l Pl 1310 l Tl
1301 l Pl
1320 AH AL LS
Engine
RY
RZ
Auto
filter
1302 AH PDS
To be positioned as close
as possible to the engine
Manual filter
Oil Filling
Pipe
Purifier or
Fine Filter Unit
Cooling water
outlet
Cooling water
inlet
Temperature Control
valve
Drain to Waste
Oil Tank
178 53 395.0
Fig. 8.09.01: Hydraulic control oil system, manual flter
MAN B&W
Page 4 of 4
MAN Diesel
Hydraulic Control Oil System
8.09
198 79 70-1.0 MAN B&W K98ME/ME-C7, S90ME-C8, K90ME/ME-C9,
S80ME-C8, S/L70ME-C8, S70ME-C8-GI, S/L60ME-C8,
S60ME-C8-GI
This section is available on request
for
K98ME/ME-C7, S90ME-C8, K90ME/ME-C9,
S80ME-C8, S/L70ME-C8, S/L60ME-C8
as well as for
S70ME-C8-GI, S60ME-C8-GI
MAN B&W 8.09
Page of
MAN Diesel
MAN B&W K80ME-C9 198 55 95-2.0
Hydraulic Control Oil System, K80ME-C9
Fig. 8.09.02: Hydraulic control oil system
178 56 36-6.0
Cylinder No.: 6 7 8 9 10 11 12
r/min 104 104 104 104 104 104 104
kW 27,180 31,710 36,240 40,770 45,300 49,830 54,360
Hydraulic Control Oil tank:
Volumen, approx. m
3
5 6 7 7,5 8,5 9,5 10
Hydraulic Control Oil Pump:
Pump capacity m
3
/h 80 90 105 120 130 15 155
Pump head bar
Delivery pressure bar
Design temperature C 70 70 70 70 70 70 70
Oil viscosity range cSt 15 - 90 15 - 90 15 - 90 15 - 90 15 - 90 15 - 90 15 - 90
Pressure Control Valve:
Lubricating oil fow m
3
/h 80 90 105 120 130 15 155
Adjustable pressure bar 2 - 2 - 2 - 2 - 2 - 2 - 2 -
Design temperature C 55 55 55 55 55 55 55
Oil viscosity range cSt 15 - 90 15 - 90 15 - 90 15 - 90 15 - 90 15 - 90 15 - 90
Hydraulic Control Oil Cooler:
Heat dissipation kW 295 30 390 0 85 535 585
Lubricating oil fow m
3
/h 80 90 105 120 130 15 155
Oil outlet temperature C 5 5 5 5 5 5 5
Oil pressure drop, max bar 0.5 0.5 0.5 0.5 0.5 0.5 0.5
Cooling water fow m
3
/h 2 9 56 63 70 77 8
S.W. inlet temperature C 32 32 32 32 32 32 32
F.W. inlet temperature C 36 36 36 36 36 36 36
Water press. drop, max. bar 0.2 0.2 0.2 0.2 0.2 0.2 0.2
Temperature Controlled Three-way Valve:
Lubricating oil fow m
3
/h 80 90 105 120 130 15 155
Adjustable temp. Range C 2 - 2 - 2 - 2 - 2 - 2 - 2 -
Design temperature C 70 70 70 70 70 70 70
Oil press. drop, max. bar 0.3 0.3 0.3 0.3 0.3 0.3 0.3
Hydraulic Control Oil Filter:
Lubricating oil fow m
3
/h 80 90 105 120 130 15 155
Absolute fneness micron 50 50 50 50 50 50 50
Design temperature C 55 55 55 55 55 55 55
Design pressure bar
Oil press. drop, max. bar 0.3 0.3 0.3 0.3 0.3 0.3 0.3
MAN B&W 8.09
Page of
MAN Diesel
MAN B&W K80ME-C6 198 51 47-2.1
Hydraulic Control Oil System, K80ME-C6
Fig. 8.09.02: Hydraulic control oil system
178 54 38-9.0
Cylinder No.: 6 7 8 9 10 11 12
r/min 10 10 10 10 10 10 10
kW 21,660 25,270 28,880 32,90 36,100 39,710 3,320
Hydraulic Control Oil tank:
Volumen, approx. m 5.5 6.5 7.5 8 9 10 11
Hydraulic Control Oil Pump:
Pump capacity m/h 85 100 115 130 15 160 170
Pump head bar
Delivery pressure bar
Design temperature C 70 70 70 70 70 70 70
Oil viscosity range cSt 15 - 90 15 - 90 15 - 90 15 - 90 15 - 90 15 - 90 15 - 90
Pressure Control Valve:
Lubricating oil fow m/h 85 100 115 130 15 160 170
Design pressure bar
Adjustable pressure bar 2 - 2 - 2 - 2 - 2 - 2 - 2 -
Design temperature C 55 55 55 55 55 55 55
Oil viscosity range cSt 15 - 90 15 - 90 15 - 90 15 - 90 15 - 90 15 - 90 15 - 90
Hydraulic Control Oil Cooler:
Heat dissipation kW 310 360 15 65 515 565 620
Lubricating oil fow m/h 85 100 115 130 15 160 170
Oil outlet temperature C 5 5 5 5 5 5 5
Design pressure, oil side bar
Oil pressure drop, max bar 0.5 0.5 0.5 0.5 0.5 0.5 0.5
Cooling water fow m/h 5 52 60 67 7 82 89
S.W. inlet temperature C 32 32 32 32 32 32 32
F.W. inlet temperature C 36 36 36 36 36 36 36
Water press. drop, max. bar 0.2 0.2 0.2 0.2 0.2 0.2 0.2
Temperature Controlled Three-way Valve:
Lubricating oil fow m/h 85 100 115 130 15 160 170
Design pressure bar
Temperature set point C 5 5 5 5 5 5 5
Design temperature C 70 70 70 70 70 70 70
Oil press. drop, max. bar 0.3 0.3 0.3 0.3 0.3 0.3 0.3
Hydraulic Control Oil Filter:
Lubricating oil fow m/h 85 100 115 130 15 160 170
Absolute fneness m 50 50 50 50 50 50 50
Design temperature C 55 55 55 55 55 55 55
Design pressure bar
Oil press. drop, max. bar 0.3 0.3 0.3 0.3 0.3 0.3 0.3
MAN B&W 8.09
Page 4 of 4
MAN Diesel
MAN B&W S65ME-C8 198 51 518.2
Hydraulic Control Oil System, S65ME-C8
Fig. 8.09.02: Hydraulic control oil system
178 54 42-4.0
Cylinder No.: 5 6 7 8
r/min 95 95 95 95
kW 14,350 17,220 20,090 22,960
Hydraulic Control Oil tank:
Volumen, approx. m 3 3.5 4 4.5
Hydraulic Control Oil Pump:
Pump capacity m/h 45 55 60 70
Pump head bar 4 4 4 4
Delivery pressure bar 4 4 4 4
Design temperature C 70 70 70 70
Oil viscosity range cSt 15 - 90 15 - 90 15 - 90 15 - 90
Pressure Control Valve:
Lubricating oil ow m/h 45 55 60 70
Design pressure bar 4 4 4 4
Adjustable pressure bar 2 - 4 2 - 4 2 - 4 2 - 4
Design temperature C 55 55 55 55
Oil viscosity range cSt 15 - 90 15 - 90 15 - 90 15 - 90
Hydraulic Control Oil Cooler:
Heat dissipation kW 155 185 215 245
Lubricating oil ow m/h 45 55 60 70
Oil outlet temperature C 45 45 45 45
Design pressure, oil side bar 4 4 4 4
Oil pressure drop, max bar 0.5 0.5 0.5 0.5
Cooling water ow m/h 23 27 31 36
S.W. inlet temperature C 32 32 32 32
F.W. inlet temperature C 36 36 36 36
Water press. drop, max. bar 0.2 0.2 0.2 0.2
Temperature Controlled Three-way Valve:
Lubricating oil ow m/h 45 55 60 70
Design pressure bar 4 4 4 4
Temperature set point C 45 45 45 45
Design temperature C 70 70 70 70
Oil press. drop, max. bar 0.3 0.3 0.3 0.3
Hydraulic Control Oil Filter:
Lubricating oil ow m/h 45 55 60 70
Absolute neness m 50 50 50 50
Design temperature C 55 55 55 55
Design pressure bar 4 4 4 4
Oil press. drop, max. bar 0.3 0.3 0.3 0.3
MAN B&W
MAN Diesel
Cylinder Lubrication

9
MAN B&W 9.01
Page 1 of 1
MAN Diesel
MAN B&W ME/MEC/ME-B engines 198 48 224.6
Company Cylinder oil
SAE 50, BN 60-80
Cylinder oil
SAE 50, BN 40-50
BP Energol CLO 50 M
Energol CL 605
Energol CL 505
Energol CL-DX 405
Castrol Cyltech 70 / 80AW Cyltech 40 SX / 50 S
Chevron *) Taro Special HT 70 Taro Special HT LS 40
ExxonMobil Mobilgard 570 Mobilgard L540
Shell Alexia 50 Alexia LS
Total Talusia Universal
Talusia HR 70
Talusia LS 40
*) Includes Caltex, Chevron and Texaco
Cylinder Lubricating Oil System
The cost of the cylinder lubricating oil is one of the
largest contributions to total operating costs, next
to the fuel oil cost. Another aspect is that the lu-
brication rate has a great inuence on the cylinder
condition, and thus on the overhauling schedules
and maintenance costs.
It is therefore of the utmost importance that the
cylinder lubricating oil system as well as its opera-
tion is optimised.
Cylinder oils
Cylinder oils should, preferably, be of the SAE 50
viscosity grade.
Modern highrated twostroke engines have a
relatively great demand for detergency in the cyl-
inder oil. Therefore cylinder oils should be chosen
according to the below list.
A BN 70 cylinder oil is to be used as the default
choice of oil and it may be used on all fuel types.
However, in case of the engine running on fuel
with sulphur content lower than 1.5% for more
than 1 to 2 weeks, we recommend to change to a
lower BN cylinder oil such as BN 40-50.
The cylinder oils listed below have all given long-
term satisfactory service during heavy fuel opera-
tion in MAN B&W engine installations:
Cylinder oil feed rate (dosage)
Adjustment of the cylinder oil dosage to the sul-
phur content in the fuel being burnt is further ex-
plained in Section 9.02.
Also other brands have been used with satisfac-
tory results.
MAN B&W 9.02
Page 1 of 6
MAN Diesel
MAN B&W K98ME/MEC, S90ME-C, K90ME/ME-C,
S80ME-C, K80ME-C, S70ME-C/ME-GI, L70ME-C,
S65ME-C/ME-GI, S60ME-C/ME-GI/ME-B, L60ME-C
198 38 890.8
MAN B&W Alpha Cylinder Lubrication System
The MAN B&W Alpha cylinder lubrication system,
see Figs. 9.02.02a and 9.02.02b, is designed to
supply cylinder oil intermittently, e.g. every four
engine revolutions with electronically controlled
timing and dosage at a dened position.
The cylinder lubricating oil is pumped from the
cylinder oil storage tank to the service tank, the
size of which depends on the owners and the
yards requirements, it is normally dimensioned
for minimum two days cylinder lubricating oil
consumption.
Cylinder lubricating oil is fed to the Alpha cylinder
lubrication system by gravity from the service
tank.
The storage tank and the service tank may alter-
natively be one and the same tank.
The oil fed to the injectors is pressurised by
means of the Alpha Lubricator which is placed
on the HCU and equipped with small multipiston
pumps.
The oil pipes tted on the engine is shown in Fig.
9.02.04.
The whole system is controlled by the Cylinder
Control Unit (CCU) which controls the injection
frequency on the basis of the enginespeed signal
given by the tacho signal and the fuel index.

Prior to start-up, the cylinders can be prelubric-
ated and, during the runningin period, the opera-
tor can choose to increase the lubricating oil feed
rate to a max. setting of 200%.
The MAN B&W Alpha Cylinder Lubricator is pref-
erably to be controlled in accordance with the Al-
pha ACC (Adaptive Cylinder oil Control) feed rate
system.
The yard supply should be according to the items
shown in Fig. 9.02.02a within the broken line. With
regard to the lter and the small box, plese see
Fig. 9.02.05.
Alpha Adaptive Cylinder Oil
Control (Alpha ACC)

It is a wellknown fact that the actual need for
cylinder oil quantity varies with the operational
conditions such as load and fuel oil quality. Con-
sequently, in order to perform the optimal lubrica-
tion costeffectively as well as technically the
cylinder lubricating oil dosage should follow such
operational variations accordingly.
The Alpha lubricating system offers the possibility
of saving a considerable amount of cylinder lubri-
cating oil per year and, at the same time, to obtain
a safer and more predictable cylinder condition.
Working principle
The basic feed rate control should be adjusted in
relation to the actual fuel quality and amount be-
ing burnt at any given time. The sulphur percent-
age is a good indicator in relation to wear, and an
oil dosage proportional to the sulphur level will
give the best overall cylinder condition.
The following two criteria determine the control:
The cylinder oil dosage shall be proportional to
the sulphur percentage in the fuel
The cylinder oil dosage shall be proportional to
the engine load (i.e. the amount of fuel entering
the cylinders).
The implementation of the above two criteria will
lead to an optimal cylinder oil dosage, proportion-
al to the amount of sulphur entering the cylinders.
MAN B&W 9.02
Page 2 of 6
MAN Diesel
198 38 890.8 MAN B&W K98ME/MEC, S90ME-C, K90ME/ME-C,
S80ME-C, K80ME-C, S70ME-C/ME-GI, L70ME-C,
S65ME-C/ME-GI, S60ME-C/ME-GI/ME-B, L60ME-C
Fig 9.02.01: Cylinder lubricating oil dosage with Alpha ACC at all loads (BN 70 cylinder oil) after running-in
Basic and minimum setting with Alpha ACC
The recommendations are valid for all plants,
whether controllable pitch or xed pitch propellers
are used.
Safe and very lubricatingeconomical control after
running-in is obtained with a basic setting accord-
ing to the formula:
Basic lubricating oil setting = 0.20 g/kWh x S%
with a minimum setting of 0.60 g/kWh, i.e. the set-
ting should be kept constant from about 3% sul-
phur and downwards.
Due to the sulphur dependency, the average cyl-
inder oil dosages rely on the sulphur distribution
in worldwide fuel bunkers. Based on deliveries all
over the world, the resulting yearly specic cylin-
der oil dosage is close to 0.65 g/kWh.
Further information on cylinder oil as a function of
fuel oil sulphur content and alkalinity of lubricating
oil is available from MAN Diesel.
Absolute dosage (g/kWh)
0.00
Sulphur %
0.10
0.20
0.30
0.40
0.50
0.60
0.70
0.80
0.90
1.00
1.10
1.20
1.30
1.40
0 0.5 1 1.5 2 2.5 3 3.5 4
178 61 196.0
MAN B&W 9.02
Page 1 of 6
MAN Diesel
198 76 119.0 MAN B&W S50MEC/ME-B, S46ME-B, S40ME-B,
S35ME-B
MAN B&W Alpha Cylinder Lubrication System
The MAN B&W Alpha cylinder lubrication system,
see Figs. 9.02.02a and 9.02.02b, is designed to
supply cylinder oil intermittently, e.g. every four
engine revolutions with electronically controlled
timing and dosage at a dened position.
The cylinder lubricating oil is pumped from the
cylinder oil storage tank to the service tank, the
size of which depends on the owners and the
yards requirements, it is normally dimensioned
for minimum two days cylinder lubricating oil
consumption.
Cylinder lubricating oil is fed to the Alpha cylinder
lubrication system by gravity from the service
tank.
The storage tank and the service tank may alter-
natively be one and the same tank.
The oil fed to the injectors is pressurised by
means of the Alpha Lubricator which is placed
on the HCU and equipped with small multipiston
pumps.
The oil pipes tted on the engine is shown in Fig.
9.02.04.
The whole system is controlled by the Cylinder
Control Unit (CCU) which controls the injection
frequency on the basis of the enginespeed signal
given by the tacho signal and the fuel index.

Prior to start-up, the cylinders can be prelubric-
ated and, during the runningin period, the opera-
tor can choose to increase the lubricating oil feed
rate to a max. setting of 200%.
The MAN B&W Alpha Cylinder Lubricator is pref-
erably to be controlled in accordance with the Al-
pha ACC (Adaptive Cylinder oil Control) feed rate
system.
The yard supply should be according to the items
shown in Fig. 9.02.02a within the broken line. With
regard to the lter and the small box, plese see
Fig. 9.02.05.
Alpha Adaptive Cylinder Oil
Control (Alpha ACC)

It is a wellknown fact that the actual need for
cylinder oil quantity varies with the operational
conditions such as load and fuel oil quality. Con-
sequently, in order to perform the optimal lubrica-
tion costeffectively as well as technically the
cylinder lubricating oil dosage should follow such
operational variations accordingly.
The Alpha lubricating system offers the possibility
of saving a considerable amount of cylinder lubri-
cating oil per year and, at the same time, to obtain
a safer and more predictable cylinder condition.
Working principle
The basic feed rate control should be adjusted in
relation to the actual fuel quality and amount be-
ing burnt at any given time. The sulphur percent-
age is a good indicator in relation to wear, and an
oil dosage proportional to the sulphur level will
give the best overall cylinder condition.
The following two criteria determine the control:
The cylinder oil dosage shall be proportional to
the sulphur percentage in the fuel
The cylinder oil dosage shall be proportional to
the engine load (i.e. the amount of fuel entering
the cylinders).
The implementation of the above two criteria will
lead to an optimal cylinder oil dosage, proportion-
al to the amount of sulphur entering the cylinders.
MAN B&W 9.02
Page 2 of 6
MAN Diesel
MAN B&W S50MEC/ME-B, S46ME-B, S40ME-B,
S35ME-B
198 76 119.0
Fig 9.02.01: Cylinder lubricating oil dosage with Alpha ACC at all loads (BN 70 cylinder oil) after running-in
Basic and minimum setting with Alpha ACC
The recommendations are valid for all plants,
whether controllable pitch or xed pitch propellers
are used.
Safe and very lubricatingeconomical control after
running-in is obtained with a basic setting accord-
ing to the formula:
Basic lubricating oil setting = 0.26 g/kWh x S%
with a minimum setting of 0.60 g/kWh, i.e. the
setting should be kept constant from about 2.3%
sulphur and downwards.
Sulphur %
Absolute dosage (g/kWh)
0.00
0.10
0.20
0.30
0.40
0.50
0.60
0.70
0.80
0.90
1.00
1.10
1.20
1.30
1.40
0 0.5 1 1.5 2 2.5 3 3.5 4
178 61 184.0
Due to the sulphur dependency, the average cyl-
inder oil dosages rely on the sulphur distribution
in worldwide fuel bunkers. Based on deliveries all
over the world, the resulting yearly specic cylin-
der oil dosage is close to 0.7 g/kWh.
Further information on cylinder oil as a function of
fuel oil sulphur content and alkalinity of lubricating
oil is available from MAN Diesel.
MAN B&W 9.02
Page 3 of 6
MAN Diesel
MAN B&W ME/MEC/MEGI/ME-B engines 198 76 120.0
Fig. 9.02.02a: Cylinder lubricating oil system with dual service tanks for two different TBN cylinder oils
0079 33 17-1.0.0
In case of low engine room temperature, it can be
difcult to keep the cylinder oil temperature at 45
C at the MAN B&W Alpha Lubricator, mounted on
the hydraulic cylinder.
Therefore the cylinder oil pipe from the small tank,
see Figs. 9.02.02a and 9.02.02b, in the vessel and
of the main cylinder oil pipe on the engine is insu-
lated and electricallly heated.
The engine builder is to make the insulation and
heating on the main cylinder oil pipe on the en-
gine. Moreover, the engine builder is to mount the
junction box and the thermostat on the engine.
See Fig. 9.02.03.
The ship yard is to make the insulation of the
cylinder oil pipe in the engine room. The heat-
ing cable supplied by the engine builder is to be
mounted from the small tank to the juntion box on
the engine. See Figs. 9.02.02a and 9.02.02b.
Deck
AC
Cylinder oil
storage or
service tank
Heater with set
point of 45C
Small box for
heater element
Level
alarm
LS 8212 AL
TI
100
Heating cable
engine builder
supply
Terminal box
El. connection
101
Filling pipe
Cylinder oil
storage or
service tank
Internal connection
changes both at the
same time
TBN
70/80
TBN
30/40
M
i
n
.


2
,
0
0
0

m
m
M
i
n
.


3
,
0
0
0

m
m
Heating cable
Insulation
Lubricating
oil pipe
Alutape
Sensor
Pipe with insulation and
el. heat tracing
Filling pipe
S
h
i
p

b
u
i
l
d
e
r
Cylinder Oil Pipe Heating
MAN B&W 9.02
Page 4 of 6
MAN Diesel
MAN B&W ME/MEC/GI engines 198 55 20-9.2
Feedback sensor
Flow sensor Flow sensor
L
u
b
r
i
c
a
t
o
r

L
u
b
r
i
c
a
t
o
r

Cylinder
liner
Cylinder
liner
Feedback sensor
Solenoid valve Solenoid valve
Cylinder
Control Unit
To other
cylinders
Hydraulic
Cylinder Unit
Hydraulic
Cylinder Unit

200 bar
system oil
Cylinder
Control Unit
Terminal box
Temperature
switch
F
o
r
w
a
r
d

c
y
l

A
f
t

c
y
l

Terminal box
Temperature switch
AC Cylinder lubrication
Power Input
Heating cable
ship builder
supply
Power
Input
Heating cable
ship builder
supply

Fig. 9.02.02b: Cylinder lubricating oil system. Example from 80/70/65ME-C engines
178 49 834.6b
Fig. 9.02.03: Electric heating of cylinder oil pipes
178 53 716.0
MAN B&W 9.02
Page 5 of 6
MAN Diesel
MAN B&W ME/MEC/GI engines 198 55 20-9.2
6050MEC 8065MEC 9890ME/MEC
Lubricator
Drain
AC
Solonoid valve
Feedback sensor
ZV 8204 C
ZT 8203 C
TE 8202 I AH
The letters refer to list of Counterflanges
The item No refer to Guidance Values Automation
Flow sensor
178 54 68-8.3
Fig. 9.02.04: Cylinder lubricating oil pipes
MAN B&W 9.02
Page 6 of 6
MAN Diesel
MAN B&W ME/MEC/MEB/-GI engines 198 79 37-9.0
Box, 37 l
XC 8212 AL
From cylinder oil service
tank/storage tank
Flange: 140
4x18 PCD 100
(EN36F00420)
250
mesh filter
Level switch
9
2
5
1
5
4
113
460
7
4
425
850
920
91
1
1
2
To venting of cylinder
oil service tank
Flange: 140
4x18 PCD 100
(EN36F00420)
4x19
for mounting
Coupling box for
heating element
and level switch
Temperature
indicator
To engine
connection AC
Flange 140
4x18 PCD 100
(EN362F0042)
Heating element 750 W
Set point 40 C
Drain from tray G 3/8
1
9
3
2
3
9
260
268
410
178 52 758.1
Fig. 9.02.05: Suggestion for small heating box with lter
MAN B&W
MAN Diesel
Piston Rod Stufng
Box Drain Oil
10
MAN B&W 10.01
Page 1 of 1
MAN Diesel
MAN B&W MC/MCC, ME/MEC/MEGI/ME-B engines 198 39 740.5
Stufng Box Drain Oil System
For engines running on heavy fuel, it is important
that the oil drained from the piston rod stufng
boxes is not led directly into the system oil, as
the oil drained from the stufng box is mixed with
sludge from the scavenge air space.
The performance of the piston rod stufng box on
the engines has proved to be very efcient, pri-
marily because the hardened piston rod allows a
higher scraper ring pressure.
The amount of drain oil from the stufng boxes is
about 5 10 litres/24 hours per cylinder during
normal service. In the runningin period, it can be
higher.
The relatively small amount of drain oil is led to
the general oily waste drain tank or is burnt in the
incinerator, Fig. 10.01.01. (Yards supply).
32 mm
nom. bore
Yards supply
Oily waste drain tank
AG
LS AH
Drain
tank
198 97 448.1
Fig. 10.01.01: Stufng box drain oil system
MAN B&W
MAN Diesel
Central Cooling
Water System
11
MAN B&W 11.01
Page 1 of 1
MAN Diesel
MAN B&W MC/MCC, ME/MEC/ME-B/GI engines 198 46 965.4
The water cooling can be arranged in several con-
gurations, the most common system choice be-
ing a Central cooling water system.
Advantages of the central cooling system:
Only one heat exchanger cooled by seawater,
and thus, only one exchanger to be overhauled
All other heat exchangers are freshwater cooled
and can, therefore, be made of a less expensive
material
Few noncorrosive pipes to be installed
Reduced maintenance of coolers and compo-
nents
Increased heat utilisation.
Disadvantages of the central cooling system:
Three sets of cooling water pumps (seawater,
central water and jacket water.
Higher rst cost.
For information on the alternative Seawater Cool-
ing System, see Chapter 12.
An arrangement common for the main engine
and MAN Diesel auxiliary engines is available on
request.
For further information about common cooling
water system for main engines and auxiliary en-
gines please refer to our publication:
Uni-concept Auxiliary Systems for Two-Stroke Main
Engines and Four-Stroke Auxiliary Engines
The publication is available at
www.mandieselturbo.com under Products
Marine Engines & Systems Low Speed
Technical Papers.
Central Cooling Water System
MAN B&W 11.02
Page 1 of 2
MAN Diesel
MAN B&W MC/MCC, ME/MEC/ME-B/GI engines 198 38 99-7.3
Central Cooling Water System
Fig. 11.02.01: Central cooling system
The central cooling water system is characterised
by having only one heat exchanger cooled by
seawater, and by the other coolers, including the
jacket water cooler, being cooled by the freshwa-
ter low temperature (FWLT) system.
In order to prevent too high a scavenge air tem-
perature, the cooling water design temperature in
the FWLT system is normally 36 C, correspond-
ing to a maximum seawater temperature of 32 C.
Our recommendation of keeping the cooling water
inlet temperature to the main engine scavenge
air cooler as low as possible also applies to the
central cooling system. This means that the tem-
perature control valve in the FWLT circuit is to be
set to minimum 10 C, whereby the temperature
follows the outboard seawater temperature when
this exceeds 10 C.
For external pipe connections, we prescribe the
following maximum water velocities:
Jacket water ................................................ 3.0 m/s
Central cooling water (FWLT) .................... 3.0 m/s
Seawater ..................................................... 3.0 m/s
Central cooling water
Jacket cooling water
Sea water
Sea water
outlet
Thermostatic
valve
Thermostatic
valve
Scavenge
air cooler(s)
Main engine
Expansion tank
for fresh water
Lub. oil
cooler
Jacket
water cool.
Fresh water
generator
Jacket water
pumps
F3
P K
M L
N
F3 F3
G2 G2 G2 G1 G1 G1
Central
cooler
Central cooling
water pumps
Sea water
pumps
Sea water
inlet
Sea water
inlet
Sea water
pump aux.
eng. (port
service)
Central cooling
water pump aux.
eng. (port service)
Deaerating tank
alarm device
Deaerating
tank

Open at sea
Closed in port
Closed at sea
Open in port
Deaerating
Port service
A
A
A
B
B
B
B
178 50 218.1
MAN B&W 11.02
Page 2 of 2
MAN Diesel
MAN B&W MC/MCC, ME/MEC/ME-B/GI engines 198 38 99-7.3
Central Cooling System, common for Main Engine and MAN Diesel GenSets
Design features and working principle
The camshaft lubricating oil cooler, is omitted in
plants using the unilubricating oil system for the
main engine.
The low and high temperature systems are direct-
ly connected to gain the advantage of preheating
the main engine and GenSets during standstill.
As all fresh cooling water is inhibited and common
for the central cooling system, only one common
expansion tank, is necessary for deaeration of
both the low and high temperature cooling sys-
tems. This tank accommodates the difference in
water volume caused by changes in the tempera-
ture.
To prevent the accumulation of air in the cooling
water system, a deaerating tank, is located below
the expansion tank.
An alarm device is inserted between the deaerat-
ing tank and the expansion tank so that the oper-
ating crew can be warned if excess air or gas is
released, as this signals a malfunction of engine
components.
Operation at sea
The seawater cooling pump, supplies seawater
from the sea chests through the central cooler,
and overboard. Alternatively, some shipyards use
a pumpless scoop system.
On the freshwater side, the central cooling water
pump, circulates the lowtemperature fresh water,
in a cooling circuit, directly through the lubricating
oil cooler of the main engine, the GenSets and the
scavenge air cooler(s).
The jacket water cooling system for the GenSets
is equipped with enginedriven pumps and a by
pass system integrated in the lowtemperature
system.
The main engine jacket system has an independ-
ent pump circuit with a jacket water pump, circu-
lating the cooling water through the main engine
to the fresh water generator, and the jacket water
cooler.
A thermostatically controlled 3way valve, at the
jacket cooler outlet mixes cooled and uncooled
water to maintain an outlet water temperature of
8085 C from the main engine.
Operation in port
During operation in port, when the main engine
is stopped but one or more GenSets are running,
valves A are closed and valves B are opened.
A small central water pump, will circulate the
necessary ow of water for the air cooler, the lu-
bricating oil cooler, and the jacket cooler of the
GenSets. The auxiliary enginesdriven pumps and
the previously mentioned integrated loop ensure
a satisfactory jacket cooling water temperature at
the GenSets outlet.
The main engine and the stopped GenSets are
preheated as described for the jacket water sys-
tem.
The other data for the jacket cooling water system
can be found in Chapter 06.06.
For further information about a common cooling
water system for main engines and MAN Diesel
auxiliary engines please refer to our publication:
Uni-concept Auxiliary Systems for Two-Stroke Main
Engines and Four-Stroke Auxiliary Engines
The publication is available at
www.mandieselturbo.com under Products
Marine Engines & Systems Low Speed
Technical Papers.
MAN B&W 11.03
Page 1 of 2
MAN Diesel
MAN B&W MC/MCC, ME/MEC/ME-B/GI engines 198 39 872.5
Components for Central Cooling Water System
Central cooling water pumps
The pumps are to be of the centrifugal type.
Central cooling water ow ... see List of Capacities
Pump head ................................................... 2.5 bar
Delivery pressure ............... depends on location of
expansion tank
Test pressure .....................according to class rules
Working temperature ..................................... 80 C
Design temperature ...................................... 100 C
The ow capacity must be within a range from
100 to 110% of the capacity stated.
The List of Capacities covers the main engine
only. The differential pressure provided by the
pumps is to be determined on the basis of the to-
tal actual pressure drop across the cooling water
system.
Central cooling water thermostatic valve
The low temperature cooling system is to be
equipped with a threeway valve, mounted as a
mixing valve, which bypasses all or part of the
fresh water around the central cooler.
The sensor is to be located at the outlet pipe from
the thermostatic valve and is set so as to keep a
temperature level of minimum 10 C.
Seawater cooling pumps
The pumps are to be of the centrifugal type.
Seawater ow ..................... see List of Capacities
Pump head ................................................... 2.5 bar
Test pressure .....................according to class rules
Working temperature, normal .....................032 C
Working temperature .................... maximum 50 C
The ow capacity must be within a range from
100 to 110% of the capacity stated.
The differential pressure of the pumps is to be de-
termined on the basis of the total actual pressure
drop across the cooling water system.
Central cooler
The cooler is to be of the shell and tube or plate
heat exchanger type, made of seawater resistant
material.
Heat dissipation ..................... see List of Capacities
Central cooling water ow ..... see List of Capacities
Central cooling water temperature, outlet ......... 36 C
Pressure drop on central cooling side ....max. 0.2 bar
Seawater ow ........................ see List of Capacities
Seawater temperature, inlet ............................. 32 C
Pressure drop on
seawater side ................................ maximum 0.2 bar
The pressure drop may be larger, depending on
the actual cooler design.
The heat dissipation and the seawater ow gures
are based on MCR output at tropical conditions,
i.e. a seawater temperature of 32 C and an ambi-
ent air temperature of 45 C.
Overload running at tropical conditions will slightly
increase the temperature level in the cooling sys-
tem, and will also slightly inuence the engine
performance.
MAN B&W 11.03
Page 2 of 2
MAN Diesel
MAN B&W MC/MCC, ME/MEC/ME-B/GI engines 198 39 872.5
Jacket water system
Due to the central cooler the cooling water inlet
temperature is about 4 C higher for for this sys-
tem compared to the seawater cooling system.
The input data are therefore different for the scav-
enge air cooler, the lube oil cooler and the jacket
water cooler.
The heat dissipation and the central cooling water
ow gures are based on an MCR output at tropi-
cal conditions, i.e. a maximum seawater tempera-
ture of 32 C and an ambient air temperature of
45 C.
Jacket water cooling pump
The pumps are to be of the centrifugal type.
Jacket water ow ............... see List of Capacities
Pump head ...................................................3.0 bar
Delivery pressure ............... depends on location of
expansion tank
Test pressure .....................according to class rules
Working temperature ..................................... 80 C
Design temperature ...................................... 100 C
The ow capacity must be within a range from
100 to 110% of the capacity stated.
The stated of capacities cover the main engine
only. The pump head of the pumps is to be de-
termined on the basis of the total actual pressure
drop across the cooling water system.
Scavenge air cooler
The scavenge air cooler is an integrated part of
the main engine.
Heat dissipation ..................... see List of Capacities
Central cooling water ow ..... see List of Capacities
Central cooling temperature, inlet .................... 36 C
Pressure drop on FWLT water side .... approx. 0.5 bar
Lubricating oil cooler
See Chapter 8 Lubricating Oil.
Jacket water cooler
The cooler is to be of the shell and tube or plate
heat exchanger type.
Heat dissipation ................. see List of Capacities
Jacket water ow ............... see List of Capacities
Jacket water temperature, inlet ...................... 80 C
Pressure drop on jacket water side ....max. 0.2 bar
Central cooling water ow ... see List of Capacities
Central cooling water
temperature, inlet ..............................approx. 42 C
Pressure drop on Central
cooling water side ................................max. 0.2 bar
The other data for the jacket cooling water system
can be found in Chapter 12.
For further information about a common cooling
water system for main engines and MAN Diesel
auxiliary engines, please refer to our publication:
Uni-concept Auxiliary Systems for Two-Stroke Main
Engines and Four-Stroke Auxiliary Engines
The publication is available at
www.mandieselturbo.com under Products
Marine Engines & Systems Low Speed
Technical Papers.
MAN B&W
MAN Diesel
Seawater
Cooling System
12
MAN B&W 12.01
Page 1 of 1
MAN Diesel
MAN B&W MC/MCC, ME/MEC/MEGI/ME-B engines 198 38 924.4
The water cooling can be arranged in several con-
gurations, the most simple system choices being
seawater and central cooling water system:
A seawater cooling system and a jacket cool-
ing water system
The advantages of the seawater cooling system
are mainly related to rst cost, viz:
Only two sets of cooling water pumps (seawater
and jacket water)
Simple installation with few piping systems.
Whereas the disadvantages are:
Seawater to all coolers and thereby higher
maintenance cost
Expensive seawater piping of noncorrosive ma-
terials such as galvanised steel pipes or CuNi
pipes.
Seawater Systems
MAN B&W 12.02
Page 1 of 1
MAN Diesel
MAN B&W MC/MCC, ME/MEC/MEGI/ME-B engines 198 38 936.5
Seawater Cooling System
Fig. 12.02.01: Seawater cooling system
The letters refer to list of Counteranges
The seawater cooling system is used for cooling,
the main engine lubricating oil cooler, the jacket
water cooler and the scavenge air cooler, see Fig.
12.02.01.
The lubricating oil cooler for a PTO stepup gear
should be connected in parallel with the other
coolers. The capacity of the seawater pump is
based on the outlet temperature of the seawater
being maximum 50 C after passing through the
coolers with an inlet temperature of maximum
32 C (tropical conditions), i.e. a maximum tem-
perature increase of 18 C.
The valves located in the system tted to adjust
the distribution of cooling water ow are to be
provided with graduated scales.
The interrelated positioning of the coolers in the
system serves to achieve:
The lowest possible cooling water inlet tem-
perature to the lubricating oil cooler in order to
obtain the cheapest cooler. On the other hand,
in order to prevent the lubricating oil from stiff-
ening in cold services, the inlet cooling water
temperature should not be lower than 10 C
The lowest possible cooling water inlet tempera-
ture to the scavenge air cooler, in order to keep
the fuel oil consumption as low as possible.
198 98 132.5
Seawater
pumps
Seawater
outlet
Seawater
inlet
Seawater
inlet
Thermostatic
valve
Jacket water
cooler
Lubricating
oil cooler
Scavenge
air cooler
N
P
MAN B&W 12.03
Page of
MAN Diesel
MAN B&W MC/MCC, ME/ME-B/MEC/MEGI engines 198 49 30-2.1
Seawater Cooling Pipes
Please note that the information is to be found in
the Project Guide for the relevant engine type.
MAN B&W 12.04
Page 1 of 1
MAN Diesel
MAN B&W MC/MCC, ME/MEC/MEGI/ME-B engines 198 39 811.3
Components for Seawater Cooling System
Scavenge air cooler
The scavenge air cooler is an integrated part of
the main engine.
Heat dissipation ................. see List of Capacities
Seawater ow .................... see List of Capacities
Seawater temperature,
for seawater cooling inlet, max. ..................... 32 C
Pressure drop on
cooling water side ........... between 0.1 and 0.5 bar
The heat dissipation and the seawater ow are
based on an MCR output at tropical conditions,
i.e. seawater temperature of 32 C and an ambient
air temperature of 45 C.
Seawater thermostatic valve
The temperature control valve is a threeway valve
which can recirculate all or part of the seawater to
the pumps suction side. The sensor is to be locat-
ed at the seawater inlet to the lubricating oil cooler,
and the temperature level must be a minimum of
+10 C.
Seawater ow ..................... see List of Capacities
Temperature range,
adjustable within .................................+5 to +32 C
Seawater cooling pump
The pumps are to be of the centrifugal type.
Seawater ow ..................... see List of Capacities
Pump head ................................................... 2.5 bar
Test pressure ...................... according to class rule
Working temperature .................... maximum 50 C
The ow capacity must be within a range from
100 to 110% of the capacity stated.
Lubricating oil cooler
See Chapter 8 Lubricating Oil.
Jacket water cooler
The cooler is to be of the shell and tube or plate
heat exchanger type, made of seawater resistant
material.
Heat dissipation ................. see List of Capacities
Jacket water ow ............... see List of Capacities
Jacket water temperature, inlet ...................... 80 C
Pressure drop
on jacket water side ....................maximum 0.2 bar
Seawater ow ..................... see List of Capacities
Seawater temperature, inlet .......................... 38 C
Pressure drop on
seawater side ..............................maximum 0.2 bar
The heat dissipation and the seawater ow are
based on an MCR output at tropical conditions,
i.e. seawater temperature of 32 C and an ambient
air temperature of 45 C.
MAN B&W 12.05
Page 1 of 1
MAN Diesel
MAN B&W MC/MCC, ME/MEC/MEGI/ME-B engines 198 38 948.6
PT 8413 I
LS 8412 AL
Jacket cooling water
Sea water
Fuel oil
The letters refer to list of Counterflanges, Fig. 5.10.01
Venting pipe or automatic
venting valve to be arranged
in one end of discharge pipe.
(Opposite end of discharge
to pump)
Tracing of fuel oil
drain pipe
Drain from bedplate/cleaning
turbocharger to waste tank
M
L
AF
*) BD
AH
AN
K
AE AE
Main
engine
Alarm must be given if excess air
is separated from the water in the
deaerating tank
Orifice for adjustment of
cooling water pressure
PI
TI
TI TI
PI
Preheater
Jacket water pumps,
3 bar head
Water inlet for
cleaning turbocharger
Fresh cooling water drain
Expansion tank
Low level alarm
Alarm device box,
see Fig. 12.07.02
Normally closed valve.
To be opened when the
system is filled with
cooling water. (Manually
or automatically)
Freshwater
generator
Jacket water
cooler

Deaerating tank,
see Fig. 12.07.01
From tracing of fuel oil drain pipe *)
High level alarm
Regulating valve
Preheater pump
*) Flange BD and the tracing line are not applicable on MC/MCC engines type 42 and smaller
Jacket Cooling Water System
The jacket cooling water system is used for cool-
ing the cylinder liners, cylinder covers and ex-
haust valves of the main engine and heating of the
fuel oil drain pipes, see Fig. 12.05.01.
The jacket water pump) draws water from the
jacket water cooler outlet and delivers it to the
engine.
At the inlet to the jacket water cooler there is a
thermostatically controlled regulating valve, with
a sensor at the engine cooling water outlet, which
keeps the main engine cooling water outlet at a
temperature of 80 C.
The engine jacket water must be carefully treated,
maintained and monitored so as to avoid corro-
sion, corrosion fatigue, cavitation and scale for-
mation. It is recommended to install a preheater
if preheating is not available from the auxiliary
engines jacket cooling water system.
The venting pipe in the expansion tank should end
just below the lowest water level, and the expan-
sion tank must be located at least 5 m above the
engine cooling water outlet pipe.
The freshwater generator, if installed, may be con-
nected to the seawater system if the generator
does not have a separate cooling water pump.
The generator must be coupled in and out slowly
over a period of at least 3 minutes.
For external pipe connections, we prescribe the
following maximum water velocities:
Jacket water ................................................ 3.0 m/s
Seawater ..................................................... 3.0 m/s
Fig. 12.05.01: Jacket cooling water system
178 50 172.5
MAN B&W 12.06
Page 1 of 1
MAN Diesel
198 49 31-4.1 MAN B&W MC/ME Engine Selection Guide
Jacket Cooling Water Pipes
Please note that the information is to be found in
the Project Guide for the relevant engine type.
MAN B&W 12.07
Page 1 of 1
MAN Diesel
MAN B&W MC/MCC, ME/ME-B/MEC/MEGI engines 198 38 96-1.4
Components for Jacket Cooling Water System
The preheater capacity depends on the required
preheating time and the required temperature
increase of the engine jacket water. The tem-
perature and time relationships are shown in Fig.
12.08.01.
In general, a temperature increase of about 35 C
(from 15 C to 50 C) is required, and a preheating
time of 12 hours requires a preheater capacity of
about 1% of the engine`s nominal MCR power.
Expansion tank
The total expansion tank volume has to be ap-
proximate 10% of the total jacket cooling water
amount in the system.
Fresh water treatment
MAN Diesels recommendations for treatment of
the jacket water / freshwater are available on re-
quest.
Freshwater generator
If a generator is installed in the ship for produc-
tion of freshwater by utilising the heat in the jacket
water cooling system it should be noted that the
actual available heat in the jacket water system
is lower than indicated by the heat dissipation
gures given in the List of capacities. This is
because the latter gures are used for dimension-
ing the jacket water cooler and hence incorporate
a safety margin which can be needed when the
engine is operating under conditions such as, e.g.
overload. Normally, this margin is 10% at nominal
MCR.
The calculation of the heat actually available at
specied MCR for a derated diesel engine is stat-
ed in Chapter 6 List of capacities.
For illustration of installation of fresh water gen-
erator see Fig. 12.05.01.
Jacket water thermostatic valve
The temperature control system can be equipped
with a threeway valve mounted as a diverting
valve, which bypass all or part of the jacket water
around the jacket water cooler.
The sensor is to be located at the outlet from the
main engine, and the temperature level must be
adjustable in the range of 7090 C.
Jacket water preheater
When a preheater is installed in the jacket cool-
ing water system, its water ow, and thus the
preheater pump capacity (4 46 625), should be
about 10% of the jacket water main pump capac-
ity. Based on experience, it is recommended that
the pressure drop across the preheater should be
approx. 0.2 bar. The preheater pump and main
pump should be electrically interlocked to avoid
the risk of simultaneous operation.
MAN B&W 12.08
Page 1 of 1
MAN Diesel
MAN B&W MC/MCC, ME/MEC/MEGI/ME-B engines 198 39 860.2
Temperature at Start of Engine
In order to protect the engine, some minimum
temperature restrictions have to be considered
before starting the engine and, in order to avoid
corrosive attacks on the cylinder liners during
starting.
Normal start of engine
Normally, a minimum engine jacket water temper-
ature of 50 C is recommended before the engine
is started and run up gradually to 90% of speci-
ed MCR speed.
For running between 90% and 100% of specied
MCR speed, it is recommended that the load be
increased slowly i.e. over a period of 30 minutes.
Start of cold engine
In exceptional circumstances where it is not pos-
sible to comply with the above-mentioned recom-
mendation, a minimum of 20 C can be accepted
before the engine is started and run up slowly to
90% of specied MCR speed.
However, before exceeding 90% specied MCR
speed, a minimum engine temperature of 50 C
should be obtained and, increased slowly i.e.
over a period of at least 30 minutes.
The time period required for increasing the jacket
water temperature from 20 C to 50 C will de-
pend on the amount of water in the jacket cooling
water system, and the engine load.
Note:
The above considerations are based on the as-
sumption that the engine has already been well
runin.
Fig. 12.08.01: Jacket water preheater
178 16 631.0
Preheating of diesel engine
Preheating during standstill periods
During short stays in port (i.e. less than 45 days),
it is recommended that the engine is kept pre-
heated, the purpose being to prevent temperature
variation in the engine structure and correspond-
ing variation in thermal expansions and possible
leakages.
The jacket cooling water outlet temperature should
be kept as high as possible and should before
startingup be increased to at least 50 C, either
by means of cooling water from the auxiliary en-
gines, or by means of a builtin preheater in the
jacket cooling water system, or a combination.
Temperature
increase of
jacket water
Preheater
capacity in
% of nominal
MCR power
1.25%
1.50% 0.75%
0.50%
1.00%
60
50
40
30
20
10
0
0 10 20 30 40 50 60 70
hours
Preheating time
C
MAN B&W
MAN Diesel
Starting and Control Air

13
MAN B&W 13.01
Page 1 of 1
MAN Diesel
198 38 985.4 MAN B&W Engine Selection Guide,
MC/MCC, ME/MEC/ME-B/-GI engines
Fig. 13.01.01: Starting and control air systems
The starting air of 30 bar is supplied by the start-
ing air compressors to the starting air receivers
and from these to the main engine inlet A.
Through a reduction station, ltered compressed
air at 7 bar is supplied to the control air for ex-
haust valve air springs, through engine inlet B
Through a reduction valve, compressed air is sup-
plied at 10 bar to AP for turbocharger cleaning
(soft blast), and a minor volume used for the fuel
valve testing unit.
Please note that the air consumption for control
air, safety air, turbocharger cleaning, sealing air
for exhaust valve and for fuel valve testing unit are
momentary requirements of the consumers.
The components of the starting and control air
systems are further desribed in Section 13.02.
Starting air and control air for the GenSets can be
supplied from the same starting air receivers, as
for the main engine.
For information about a common starting air sys-
tem for main engines and MAN Diesel auxiliary
engines, please refer to our publication:
Uni-concept Auxiliary Systems for Two-Stroke Main
Engines and Four-Stroke Auxiliary Engines
The publication is available at
www.mandieselturbo.com under Products
Marine Engines & Systems Low Speed
Technical Papers.
079 61 01-7.1.1a
Oil & water
separator
To bilge
Reduction station
Pipe, DN25 mm
Pipe a, DN *)
Starting air
receiver 30 bar
Starting air
receiver 30 bar
Filter,
40 m
To
bilge
Main
engine
Air compressors
To fuel valve
testing unit
B C
1
) AP
A
Reduction valve
PI
PI Pipe, DN25 mm
The letters refer to list of Counteranges
*) The nominal dimension of Pipe a depends on the engine type
1) Engine inlet C is only applicable for MC and MC-C engines
Starting and Control Air Systems
MAN B&W 13.02
Page 1 of 1
MAN Diesel
198 60 578.1 MAN B&W ME/MEC/MEGI,
S60ME-B, S50ME-B
Components for Starting Air System
Starting air compressors
The starting air compressors are to be of the
watercooled, twostage type with intercooling.
More than two compressors may be installed to
supply the total capacity stated.
Air intake quantity:
Reversible engine,
for 12 starts ....................... see List of capacities
Nonreversible engine,
for 6 starts ......................... see List of capacities
Delivery pressure ........................................ 30 bar
Starting air receivers
The volume of the two receivers is:
Reversible engine,
for 12 starts ..................... see List of capacities *
Nonreversible engine,
for 6 starts ....................... see List of capacities *
Working pressure ........................................ 30 bar
Test pressure .................... according to class rule
* The volume stated is at 25 C and 1,000 mbar
Reduction station for control and safety air
In normal operating, each of the two lines supplies
one engine inlet. During maintenance, three isolat-
ing valves in the reduction station allow one of the
two lines to be shut down while the other line sup-
plies both engine inlets, see Fig. 13.01.01.
Reduction ......................... from 3010 bar to 7 bar
(Tolerance 10%)
Flow rate, free air .............. 2,100 Normal liters/min
equal to 0.035 m
3
/s
Filter, neness ............................................. 40 m
Reduction valve for turbocharger cleaning etc
Reduction ..........................from 3010 bar to 7 bar
(Tolerance 10%)
Flow rate, free air ............. 2,600 Normal liters/min
equal to 0.043 m
3
/s
The consumption of compressed air for control air,
exhaust valve air springs and safety air as well as
air for turbocharger cleaning and fuel valve testing
is covered by the capacities stated for air receiv-
ers and compressors in the list of capacities.
Starting and control air pipes
The piping delivered with and tted onto the main
engine is shown in the following gures in Section
13.03:
Fig. 13.03.01 Starting air pipes
Fig. 13.03.02 Air spring pipes, exhaust valves
Turning gear
The turning wheel has cylindrical teeth and is t-
ted to the thrust shaft. The turning wheel is driven
by a pinion on the terminal shaft of the turning
gear, which is mounted on the bedplate.
Engagement and disengagement of the turning
gear is effected by displacing the pinion and ter-
minal shaft axially. To prevent the main engine
from starting when the turning gear is engaged,
the turning gear is equipped with a safety arrange-
ment which interlocks with the starting air system.
The turning gear is driven by an electric motor
with a builtin gear and brake. Key specications
of the electric motor and brake are stated in Sec-
tion 13.04.
MAN B&W 13.03
Page 1 of 1
MAN Diesel
198 59 03-3.2 MAN B&W MC/ME Engine Selection Guide
Starting and Control Air Pipes
Please note that the information is to be found in
the Project Guide for the relevant engine type.
MAN B&W
MAN Diesel
Scavenge Air

14
MAN B&W 14.01
Page 1 of 1
MAN Diesel
MAN B&W MC/MCC, ME/MEC/ME-B/GI engines 198 48 60-6.3
Scavenge Air System
The engine is supplied with scavenge air from
turbochargers, located on the exhaust side of the
engine. However, some engines can be tted with
one turbocharger located on the aft end of the
engine.
The compressor of the turbocharger draws air
from the engine room, through an air lter, and
the compressed air is cooled by the scavenge
air cooler, one per turbocharger. The scavenge
air cooler is provided with a water mist catcher,
which prevents condensate water from being car-
ried with the air into the scavenge air receiver and
to the combustion chamber.
Fig. 14.01.01: Scavenge Air System
The scavenge air system is an integrated part of
the main engine, see Figs. 14.01.01 and
14.02.01.
The engine power gures and the data in the list
of capacities are based on MCR at tropical condi-
tions, i.e. a seawater temperature of 32 C, or a
freshwater temperature of 36 C, and an ambient
air intake temperature of 45 C.
178 07 274.2
Exhaust gas
receiver
Turbocharger
Scavenge
gas receiver
Scavenge
air cooler
Water mist
catcher
Exhaust valve
Cylinder liner
MAN B&W 14.02
Page 1 of 2
MAN Diesel
198 40 09-0.3 MAN B&W ME/ME-C/-GI engines
Running with auxiliary blower
Running with turbocharger
Auxiliary Blowers
The engine is provided with a minimum of two
electrically driven auxiliary blowers, the actual
number depending on the number of cylinders as
well as the turbocharger make and amount.
The auxiliary blowers are tted onto the main
engine. Between the scavenge air cooler and the
scavenge air receiver, nonreturn valves are t-
ted which close automatically when the auxiliary
blowers start supplying the scavenge air.
Auxiliary blower operation
The auxiliary blowers start operating consecu-
tively before the engine is started and will ensure
complete scavenging of the cylinders in the start-
ing phase, thus providing the best conditions for a
safe start.
During operation of the engine, the auxiliary blow-
ers will start automatically whenever the blower
inlet pressure drops below a preset pressure,
corresponding to an engine load of approximately
25-35%.
The blowers will continue to operate until the
blower inlet pressure again exceeds the preset
pressure plus an appropriate hysteresis (i.e. taking
recent pressure history into account), correspond-
ing to an engine load of approximately 30-40%.
Emergency running
If one of the auxiliary blowers is out of function,
the other auxiliary blower will function in the sys-
tem, without any manual adjustment of the valves
being necessary.
Fig. 14.02.01: Scavenge air system
178 44 705.1
MAN B&W 14.02
Page 2 of 2
MAN Diesel
MAN B&W ME/ME-C/-GI engines 198 40 09-0.3
Control of the Auxiliary Blowers
The control system for the auxiliary blowers is
integrated in the Engine Control System. The aux-
iliary blowers can be controlled in either automatic
(default) or manual mode.
In automatic mode, the auxiliary blowers are
started sequentially at the moment the engine is
commanded to start. During engine running, the
blowers are started and stopped according to
preset scavenge air pressure limits.
When the engine stops, the blowers are stopped
after 10 minutes to prevent overheating of the
blowers. When a start is ordered, the blower will
be started in the normal sequence and the actual
start of the engine will be delayed until the blow-
ers have started.
In manual mode, the blowers can be controlled
individually from the ECR (Engine Control Room)
panel irrespective of the engine condition.
Referring to Fig. 14.02.02, the Auxiliary Blower
Starter Panels control and protect the Auxiliary
Blower motors, one panel with starter per blower.
The starter panels with starters for the auxiliary
blower motors are not included, they can be or-
dered as an option: 4 55 653. (The starter panel
design and function is according to MAN Diesels
diagram, however, the physical layout and choice
of components has to be decided by the manu-
facturer).
Heaters for the blower motors are available as an
option: 4 55 155.
Scavenge air cooler requirements
The data for the scavenge air cooler is specied in
the description of the cooling water system chosen.
For further information, please refer to our publi-
cation titled:
Inuence of Ambient Temperature Conditions
The publication is available at
www.mandieselturbo.com under Products
Marine Engines & Systems Low Speed
Technical Papers.
Fig. 14.02.02: Diagram of auxiliary blower control system
Engine Control System
Engine room
Motor
heater
Motor
heater
Motor
heater
Motor
heater
Motor
heater
Power
cable
Power
cable
Power
cable
Power
cable
Power
cable
Aux. blower
starter panel 1
Auxiliary
blower
Auxiliary
blower
Auxiliary
blower
Auxiliary
blower
Auxiliary
blower
M M M M M
Aux. blower
starter panel 2
Aux. blower
starter panel 3
Aux. blower
starter panel 4
Aux. blower
starter panel 5
178 61 30-2.0
MAN B&W 14.03
Page 1 of 1
MAN Diesel
198 48 63-1.1 MAN B&W MC/ME Engine Selection Guide
Scavenge Air Pipes
Please note that the information is to be found in
the Project Guide for the relevant engine type.
MAN B&W 14.04
Page 1 of 1
MAN Diesel
198 48 64-3.1 MAN B&W MC/ME Engine Selection Guide
Electric Motor for Auxiliary Blower
Please note that the information is to be found in
the Project Guide for the relevant engine type.
MAN B&W 14.05
Page 1 of 2
MAN Diesel
198 76 84-9.0 MAN B&W K98MC/MC-C/ME/MEC, S90MC-C/MEC,
K90MC-C/ME/MEC, S80MC/MC-C/MEC, K80MC-C/MEC,
S70MC/MC-C/MEC/MEGI, L70MC-C/MEC, S65MEC/MEGI,
S60MC/MC-C/MEC/MEGI/ME-B, L60MC-C/MEC, S50ME-B9
The air side of the scavenge air cooler can be
cleaned by injecting a grease dissolving media
through AK to a spray pipe arrangement tted to
the air chamber above the air cooler element.
Drain from water mist catcher
Sludge is drained through AL to the drain water
collecting tank and the polluted grease dissolvent
returns from AM, through a lter, to the chemical
cleaning tank. The cleaning must be carried out
while the engine is at standstill.
Dirty water collected after the water mist catcher
is drained through DX and led to the bilge tank
via an open funnel, see Fig. 14.05.02.
The AL drain line is, during running, used as a
permanent drain from the air cooler water mist
catcher. The water is led through an orice to pre-
vent major losses of scavenge air.
The system is equipped with a drain box with a
level switch, indicating any excessive water level.
The piping delivered with and tted on the engine
is shown in Fig 14.05.01.
Auto Pump Overboard System
It is common practice on board to lead drain wa-
ter directly overboard via a collecting tank. Before
pumping the drain water overboard, it is recom-
mended to measure the oil content. If above
15ppm, the drain water should be lead to the
clean bilge tank / bilge holding tank.
If required by the owner, a system for automatic
disposal of drain water with oil content monitoring
could be built as outlined in Fig. 14.05.02.
The letters refer to list of Counteranges
The item no refer to Guidance values automation
Fig. 14.05.01: Air cooler cleaning pipes
Scavenge Air Cooler Cleaning System
LS 8611 AH
AK AK
AL AM
DX
DX
178 56 35-4.2
MAN B&W 14.05
Page 1 of 2
MAN Diesel
198 76 89-8.0 MAN B&W S50MC/MC-C, S50MEC, S50ME-B8,
S46MC-C, S46ME-B
The air side of the scavenge air cooler can be
cleaned by injecting a grease dissolving media
through AK to a spray pipe arrangement tted to
the air chamber above the air cooler element.
Drain from water mist catcher
Sludge is drained through AL to the drain water
collecting tank and the polluted grease dissolvent
returns from AM, through a lter, to the chemical
cleaning tank. The cleaning must be carried out
while the engine is at standstill.
The AL drain line is, during running, used as a
permanent drain from the air cooler water mist
catcher. The water is led through an orice to pre-
vent major losses of scavenge air.
The system is equipped with a drain box with a
level switch, indicating any excessive water level.
The piping delivered with and tted on the engine
is shown in Fig 14.05.01.
Auto Pump Overboard System
It is common practice on board to lead drain wa-
ter directly overboard via a collecting tank. Before
pumping the drain water overboard, it is recom-
mended to measure the oil content. If above
15ppm, the drain water should be lead to the
clean bilge tank / bilge holding tank.
If required by the owner, a system for automatic
disposal of drain water with oil content monitoring
could be built as outlined in Fig. 14.05.02.
The letters refer to list of Counteranges
The item no refer to Guidance values automation
Fig. 14.05.01: Air cooler cleaning pipes, shown on engine with turbocharger located on exhaust side
Scavenge Air Cooler Cleaning System
AK
AL AM
AK
LS 8611 AH
178 59 17-1.2
MAN B&W 14.05
Page 2 of 2
MAN Diesel
MAN B&W Engine Selection Guide 198 39 02-2.5
The letters refer to list of Counteranges
Fig. 14.05.03: Air cooler cleaning system with Air Cooler Cleaning Unit, option: 4 55 665
Air cooler Air cooler
Sludge pump suction
AM
Heating coil
To fit the chemical
makers requirement
AK
Recirculation
AL
DX
DN=50 mm
DN=50 mm
Circulation pump
Filter
1 mm mesh size
Drain from air cooler
cleaning & water mist
catcher in air cooler
DN=25 mm
PI
Freshwater
(from hydrophor)
TI
Chemical
cleaning tank
079 21 94-1.0.0a
Air Cooler Cleaning Unit
DX AL
Clean bilge tank /
bilge holding tank
Drain water
collecting tank
Overboard
High level alarm
Start pump
Stop pump
Low level alarm
Oil in water
monitor
(15ppm oil) H
u
l
l
To oily water
separator
Fig. 14.05.02: Suggested automatic disposal of drain water, if required by owner (not a demand from MAN Diesel)
079 21 94-1.0.0c
Auto Pump Overboard System
Information on tank capacity is to be found in
the Project Guide for the relevant engine type.
MAN B&W 14.06
Page 1 of 1
MAN Diesel
MAN B&W MC/MCC, ME/MEC/ME-B/GI engines 198 39 13-0.5
Scavenge Air Box Drain System
The scavenge air box is continuously drained
through AV to a small pressurised drain tank,
from where the sludge is led to the sludge tank.
Steam can be applied through BV, if required, to
facilitate the draining. See g. 14.06.01.
The continuous drain from the scavenge air box
must not be directly connected to the sludge tank
owing to the scavenge air pressure. The pres-
surised drain tank must be designed to withstand
full scavenge air pressure and, if steam is applied,
to withstand the steam pressure available.
Fig. 14.06.01: Scavenge air box drain system
The system delivered with and tted on the engine
is shown in Fig. 14.03.02 Scavenge air space,
drain pipes.
Further information on number of cylinders
and capacity of drain tank
The information is to be found in the Project Guide
for the relevant engine type.
079 61 03-0.2.0
Deck/Roof
Drain
tank
DN 50 mm
DN 65 mm
Sludge tank
for fuel oil
centrifuges
Orifice 10 mm
DN 15 mm
BV AV
Steam inlet pressure 310 bar.
If steam is not available, 7 bar
compressed air can be used.
DN 50 mm
Normally closed.
Tank to be emptied
during service with
valve open.
Normally open.
To be closed in case of fire
in the scavenge air box.
Min. distance
1,000 mm
Min. 15
The letters refer to list of Counteranges
MAN B&W 14.07
Page 1 of 2
MAN Diesel
MAN B&W MC/MCC, ME/MEC/ME-B/GI engines 198 48 65-5.4
Fire Extinguishing System for Scavenge Air Space
Fire in the scavenge air space can be extin-
guished by steam, this being the standard ver-
sion, or, optionally, by water mist or CO
2
.
The external system, pipe and ange connections
are shown in Fig. 14.07.01, comprising:
Fire extinguishing system for scavenge air space,
basic: 4 55 140 Steam
or option: 4 55 142 Water mist
or option: 4 55 143 CO
2
The corresponding internal system tted on the
engine is shown in Fig. 14.07.02, comprising:
Fire extinguishing in scavenge air space (steam)
or
Fire extinguishing in scavenge air space (water
mist) or
Fire extinguishing in scavenge air space (CO
2
).
Further information on Steam, Freshwater and
CO
2
test pressure and quantities
The information is to be found in the Project Guide
for the relevant engine type.
079 61 02-9.0.1d
AT AT
AT
Basic solution: Steam extinguishing
(Option for 26MC)
Steam pressure: 310 bar
DN 40mm
(20mm for 35MC/MCC/MEB, 26MC)
Normal position
open to bilge
Normal position
open to bilge
Option: Water mist extinguishing
(Basic for 26MC)
Fresh water presssure: min. 3.5 bar
DN 40mm
(20mm for 35MC/MCC/MEB, 26MC)
Option: CO
2
extinguishing
CO
2
test pressure: 150 bar
DN 20mm
CO
2
bottles
CO
2

At least two bottles ought to be installed.
In most cases, one bottle should be sufficient
to extinguish fire in three cylilnders, while two
or more bottles would be required to extinguish
fire in all cylinders.
To prevent the fire from spreading to the next
cylinder(s), the ballvalve of the neighbouring
cylinder(s) should be opened in the event of
fire in one cylinder.
Fig. 14.07.01: Fire extinguishing system for scavenge air space
The letters refer to list of Counteranges
MAN B&W 14.07
Page 2 of 2
MAN Diesel
MAN B&W MC/MCC, ME/MEC/ME-B/GI engines 198 48 65-5.4
126 40 81-0.6.0a
TE 8610 I AH Y
Cyl. 1
AT
Extinguishing agent:
CO
2
, Steam or Freshwater
Exhaust side
Manoeuvering side
Drain pipe, bedplate
(Only for steam or freshwater)
The letters refer to list of Counteranges
Fig. 14.07.02: Fire extinguishing pipes in scavenge air space
126 40 81-0.6.0b
TE 8610 I AH Y
Cyl. 1
AT
Extinguishing agent:
CO
2
, Steam or Freshwater
Exhaust side
Manoeuvering side
Drain pipe, bedplate
(Only for steam or freshwater)
K90MCC6/7, K80MCC6, S60MC6:
General design (except K90MCC6/7, K80MCC6, S60MC6):
Fire Extinguishing Pipes in Scavenge Air Space
MAN B&W
MAN Diesel
Exhaust Gas

15
MAN B&W 15.01
Page 1 of 1
MAN Diesel
MAN B&W MC/ME Engine Selection Guide 198 39 046.3
Exhaust Gas System
Exhaust valve
Cylinder liner
Exhaust gas
receiver
Turbocharger
Scavenge air
receiver
Scavenge
air cooler
Water mist
catcher
Fig. 15.01.01: Exhaust gas system on engine
The exhaust gas is led from the cylinders to the
exhaust gas receiver where the uctuating pres-
sures from the cylinders are equalised and from
where the gas is led further on to the turbocharg-
ers at a constant pressure. See Fig. 15.01.01.
Compensators are tted between the exhaust
valve housings and the exhaust gas receiver and
between the receiver and the turbocharger. A pro-
tective grating is placed between the exhaust gas
receiver and the turbocharger. The turbocharger
is tted with a pickup for monitoring and remote
indication of the turbocharger speed.
The exhaust gas receiver and the exhaust pipes
are provided with insulation, covered by steel
plating.
Turbocharger arrangement and cleaning systems
The turbochargers are arranged on the exhaust
side of the engine. However, some engines can be
tted with one turbocharger located on the aft end.
The engine is designed for the installation of MAN,
ABB or MHI turbochargers, the number can be
from one to four.
All makes of turbochargers are tted with an ar-
rangement for soft blast cleaning of the turbine
side. Water washing of the compressor side is ei-
ther tted or available as an option for some turbo-
chargers as indicated in Figs. 15.02.02 - 15.02.04.
Further information is found in the Project Guide
for the relevant engine.
178 07 274.1
MAN B&W 15.02
Page 1 of 3
MAN Diesel
MAN B&W K98MC/MC-C, K98ME/MEC, S90MC-C/MEC,
K90MC-C, K90ME/MEC, S80MC/MC-C, S80MEC,
K80MC-C, K80MEC, S70MC/MC-C, S70MEC/MEGI,
L70MC-C, L70MEC, S60ME-C/ME-G, L60ME-C
198 40 709.3
Cyl. 1
Flange connection D
Turbocharger
To scavenge air receiver
Exhaust gas receiver
PI 8706
PI 8601 TI 8702
TI 8701
TC 8701 I AH YH ST 8801 I
TI 8707
*) AL: Deviation alarm/Cylinder 50C
YL: Deviation alarm/Cylinder 60C
*)
TC 8702 I AH AL YH YL
Exhaust Gas Pipes
Fig. 15.02.01: Exhaust gas pipes
121 15 27-9.2.0
The letters refer to list of Counteranges
The item no. refer to Guidance Values Automation
MAN B&W 15.02
Page 1 of 3
MAN Diesel
MAN B&W S65MC-C, S65ME-C/ME-GI, S60MC/60MC-C,
S60ME-B, L60MC-C
198 64 029.1
Exhaust Gas Pipes
Fig. 15.02.01a: Exhaust gas pipes, with turbocharger located on exhaust side of engine, option 4 59 122
121 15 27-9.2.0
Cyl. 1
Flange connection D
Turbocharger
To scavenge air receiver
Exhaust gas receiver
PI 8706
PI 8601 TI 8702
TI 8701
TC 8701 I AH YH ST 8801 I
TI 8707
*) AL: Deviation alarm/Cylinder 50C
YL: Deviation alarm/Cylinder 60C
*)
TC 8702 I AH AL YH YL
The letters refer to list of Counteranges
The item no. refer to Guidance Values Automation
TI 8707
PI 8706 TI 8701
TC 8701 I AH YH
*)
TC 8702 I AH AL YH YL
*) AL: Deviation alarm/Cylinder 50C
YL: Deviation alarm/Cylinder 60C
Fore Aft
Exhaust gas receiver
To scavenge air receiver
Turbocharger
Flange connection D
ST 8801 IR
PI 8601
TI 8702
The letters refer to list of Counteranges
The item no. refer to Guidance Values Automation
The piping is delivered with and tted onto the engine
178 38 692.2
Fig.15.02.01b: Exhaust gas pipes, with turbocharger located on aft end of engine, option 4 59 124
MAN B&W 15.02
Page 1 of 2
MAN Diesel
MAN B&W S50MC6, S50MC-C/MEC7/8, S50ME-B8/9,
S46MC-C7/8, S46ME-B8, S42MC7, S40ME-B9, S40MC-C9,
S35MC-C9, S35MC7, L35MC6, S35ME-B9, S26MC6
198 40 699.4
Exhaust Gas Pipes
Fig. 15.02.01b: Exhaust gas pipes, with turbocharger located on exhaust side of engine, option 4 59 123
121 15 27-9.2.0
TI 8707
PI 8706 TI 8701
TC 8701 I AH YH
*)
TC 8702 I AH AL YH YL
*) AL: Deviation alarm/Cylinder 50C
YL: Deviation alarm/Cylinder 60C
Fore Aft
Exhaust gas receiver
To scavenge air receiver
Turbocharger
Flange connection D
ST 8801 IR
PI 8601
TI 8702
The letters refer to List of anges
The position numbers refer to List of instruments
The piping is delivered with and tted onto the engine
178 38 692.2
Fig.15.02.01a: Exhaust gas pipes, with turbocharger located on aft end of engine, option 4 59 121
Cyl. 1
Flange connection D
Turbocharger
To scavenge air receiver
Exhaust gas receiver
PI 8706
PI 8601 TI 8702
TI 8701
TC 8701 I AH YH ST 8801 I
TI 8707
*) AL: Deviation alarm/Cylinder 50C
YL: Deviation alarm/Cylinder 60C
*)
TC 8702 I AH AL YH YL
The letters refer to list of Counteranges
The item no. refer to Guidance Values Automation
MAN B&W 15.02
Page 2 of 3
MAN Diesel
198 40 710.5 MAN B&W K98MC/MC-C, K98ME/MEC, S90MC-C, S90MEC,
K90MC-C, K90ME/ME-C, S80MC/MC-C, S80MEC, K80MC-C,
K80MEC, S70MC, S/L70MC-C, S/L70MEC, S70MEGI,
S65ME-C/ME-GI, S60MC, S/L60MC-C, S/L60MEC,
S60ME-GI/ME-B
Cleaning Systems
Fig. 15.02.02: MAN Diesel TCA turbocharger, water washing of turbine side
121 15 21-8.0.0
PI 8804
AN
Compressor cleaning
MAN Diesel TCA turbocharger
To bedplate drain, AE
MAN B&W 15.02
Page 2 of 2
MAN Diesel
198 79 164.0 MAN B&W S50MC6, S50MC-C/MEC7/8, S50ME-B8/9,
S46MC-C7/8, S46ME-B8, S42MC7, S40ME-B9, S40MC-C9,
S35MC-C9, S35MC7, L35MC6, S35ME-B9, S26MC6
Cleaning Systems
Fig. 15.02.02: MAN Diesel TCA turbocharger, water washing of compressor side, option: 4 59 145
178 61 90-0.0
178 61 87-7.0.0
Compressor cleaning
MAN Diesel TCA turbocharger
To bedplate drain, AE
AP
Drain
Dry cleaning turbine side
PI 8803
ABB Turbocharger
Compressor cleaning
To bedplate drain, AE
Fig. 15.02.03: Soft blast cleaning of turbine side and water washing of compressor side for ABB turbochargers
MAN B&W 15.02
Page 3 of 3
MAN Diesel
MAN B&W K98MC/MC-C, K98ME/MEC, S90MC-C,
S90MEC, K90MC-C, K90ME/ME-C, S80MC/MC-C,
S80MEC, K80MC-C, K80MEC
198 40 722.3
Cleaning Systems
Fig. 15.02.04: Soft blast cleaning of turbine side
121 36 88-3.2.0
Fig. 15.02.03: Water washing of turbine and compressor sides for ABB, TPL turbochargers
121 36 75-1.0.0
PI 8804
ABB TPL Turbocharger
Compressor cleaning
To bedplate drain, AE
Water cleaning nozzle
Drain cock
Inlet valve
Water inlet
AN
AP
Drain
Scavenge air receiver
Dry cleaning turbine side
PI 8803
MAN B&W 15.02
Page 3 of 3
MAN Diesel
MAN B&W S70MC, S/L70MC-C, S/L70MEC, S70MEGI,
S65ME-C/ME-GI, S60MC, S/L60MC-C, S/L60MEC,
S60ME-GI/ME-B
198 40 734.7
Cleaning Systems
Fig. 15.02.04: Soft blast cleaning of turbine side
126 40 93-0.2.0
Fig. 15.02.03: Water washing of turbine and compressor sides for ABB, TPL turbochargers
121 36 75-1.0.0
PI 8804
ABB TPL Turbocharger
Compressor cleaning
To bedplate drain, AE
Water cleaning nozzle
Drain cock
Inlet valve
Water inlet
AN
AP
Drain
Dry cleaning turbine side
PI 8803
At the specied MCR of the engine, the total
backpressure in the exhaust gas system after the
turbocharger (as indicated by the static pressure
measured in the piping after the turbocharger)
must not exceed 350 mm WC (0.035 bar).
In order to have a backpressure margin for the
nal system, it is recommended at the design
stage to initially use a value of about 300 mm WC
(0.030 bar).
The actual backpressure in the exhaust gas
system at specied MCR depends on the gas
velocity, i.e. it is proportional to the square of the
exhaust gas velocity, and hence inversely propor-
tional to the pipe diameter to the 4th power. It has
by now become normal practice in order to avoid
too much pressure loss in the pipings to have an
exhaust gas velocity at specied MCR of about
35 m/sec, but not higher than 50 m/sec.
Exhaust gas piping system for main engine
The exhaust gas piping system conveys the gas
from the outlet of the turbocharger(s) to the at-
mosphere.
The exhaust piping is shown schematically in
Fig. 15.04.01.
The exhaust system for the main engine com-
prises:
Exhaust gas pipes
Exhaust gas boiler
Silencer
Spark arrester (if needed)
Expansion joints (compensators)
Pipe bracings.
In connection with dimensioning the exhaust gas
piping system, the following parameters must be
observed:
Exhaust gas ow rate
Exhaust gas temperature at turbocharger outlet
Maximum pressure drop through exhaust gas
system
Maximum noise level at gas outlet to atmos-
phere
Maximum force from exhaust piping on
turbocharger(s)
Sufcient axial and lateral elongation ability of
expansion joints
Utilisation of the heat energy of the exhaust gas.
Items that are to be calculated or read from tables
are:
Exhaust gas mass ow rate, temperature and max-
imum back pressure at turbocharger gas outlet
Diameter of exhaust gas pipes
Utilisation of the exhaust gas energy
Attenuation of noise from the exhaust pipe outlet
Pressure drop across the exhaust gas system
Expansion joints.
Exhaust Gas System for Main Engine
MAN B&W 15.03
Page 1 of 1
MAN Diesel
198 39 058.2 MAN B&W MC/ME Engine Selection Guide
MAN B&W 15.04
Page 1 of 2
MAN Diesel
198 39 071.2 MAN B&W MC/ME Engine Selection Guide
Components of the Exhaust Gas System
It should be noted that the exhaust gas tempera-
ture and ow rate are inuenced by the ambient
conditions, for which reason this should be con-
sidered when the exhaust gas boiler is planned.
At specied MCR, the maximum recommended
pressure loss across the exhaust gas boiler is nor-
mally 150 mm WC.
This pressure loss depends on the pressure loss-
es in the rest of the system as mentioned above.
Therefore, if an exhaust gas silencer/spark arrest-
er is not installed, the acceptable pressure loss
across the boiler may be somewhat higher than
the max. of 150 mm WC, whereas, if an exhaust
gas silencer/spark arrester is installed, it may be
necessary to reduce the maximum pressure loss.
The above mentioned pressure loss across the
exhaust gas boiler must include the pressure loss-
es from the inlet and outlet transition pieces.
Fig. 15.04.01a: Exhaust gas system, one turbocharger
178 42 783.2
Exhaust gas compensator after turbocharger
When dimensioning the compensator for the
expansion joint on the turbocharger gas outlet
transition piece, the exhaust gas piece and com-
ponents are to be so arranged that the thermal
expansions are absorbed by expansion joints. The
heat expansion of the pipes and the components
is to be calculated based on a temperature in-
crease from 20 C to 250 C.
Exhaust gas boiler
Engine plants are usually designed for utilisation
of the heat energy of the exhaust gas for steam
production or for heating the thermal oil system.
The exhaust gas passes an exhaust gas boiler
which is usually placed near the engine top or in
the funnel.
Turbocharger gas
outlet flange
D4
D4
D4
D4
Exhaust gas outlet
to the atmosphere
Slide support
Fixed support
Exhaust gas compensator
Main engine with turbochargers
on exhaust side
Transition piece
Exhaust gas
silencer
Exhaust gas
boiler
D0
Fig. 15.04.01b: Exhaust gas system, two or more TCs
178 33 467.4
Exhaust gas outlet
to the atmosphere
Slide support
Fixed support
Exhaust gas compensator
Main engine with
turbocharger on aft end
D0
D0
D0
Exhaust gas
silencer
Exhaust gas
boiler
MAN B&W 15.04
Page 2 of 2
MAN Diesel
MAN B&W MC/ME Engine Selection Guide 198 40 77-1.1
Exhaust gas silencer
The typical octave band sound pressure levels
from the diesel engines exhaust gas system at a
distance of one meter from the top of the exhaust
gas uptake are available on request.
The need for an exhaust gas silencer can be de-
cided based on the requirement of a maximum
permissible noise level at a specic position.
The exhaust gas noise data is valid for an exhaust
gas system without boiler and silencer, etc.
The noise level is at nominal MCR at a distance of
one metre from the exhaust gas pipe outlet edge
at an angle of 30 to the gas ow direction.
For each doubling of the distance, the noise level
will be reduced by about 6 dB (fareld law).
When the noise level at the exhaust gas outlet to
the atmosphere needs to be silenced, a silencer
can be placed in the exhaust gas piping system
after the exhaust gas boiler.
The exhaust gas silencer is usually of the absorp-
tion type and is dimensioned for a gas velocity of
approximately 35 m/s through the central tube of
the silencer.
An exhaust gas silencer can be designed based
on the required damping of noise from the ex-
haust gas given on the graph.
In the event that an exhaust gas silencer is re-
quired this depends on the actual noise level
requirement on the bridge wing, which is normally
maximum 6070 dB(A) a simple ow silencer of
the absorption type is recommended. Depending
on the manufacturer, this type of silencer nor-
mally has a pressure loss of around 20 mm WC at
specied MCR.
Spark arrester
To prevent sparks from the exhaust gas being
spread over deck houses, a spark arrester can be
tted as the last component in the exhaust gas
system.
It should be noted that a spark arrester contrib-
utes with a considerable pressure drop, which is
often a disadvantage.
It is recommended that the combined pressure
loss across the silencer and/or spark arrester
should not be allowed to exceed 100 mm WC at
specied MCR. This depends, of course, on the
pressure loss in the remaining part of the system,
thus if no exhaust gas boiler is installed, 200 mm
WC might be allowed.
MAN B&W
MAN Diesel
Engine Control System

16
MAN B&W 16.01
Page 1 of 9
MAN Diesel
MAN B&W ME/MEC engines 198 48 476.6
The Engine Control System for the ME engine is
prepared for conventional remote control, having
an interface to the Bridge Control system and the
Local Operating Panel (LOP).
A Multi-Purpose Controller (MPC) is applied as
control unit for specic tasks described below:
ACU, CCU, ECU, and EICU. The control units are
all built on the same identical piece of hardware
and differ only in the software installed.
The layout of the Engine Control System is shown
in Figs. 16.01.01a and b, the mechanicalhydraulic
system is shown in Figs. 16.01.02a and b, and the
pneumatic system, shown in Fig. 16.01.03.
The ME system has a high level of redundancy.
It has been a requirement to its design that no
single failure related to the system may cause the
engine to stop. Furthermore, the ME system has
been designed so that a single failure in most cas-
es will not, or only slightly, affect the performance
or power availability.
Main Operating Panel (MOP)
In the engine control room a MOP screen is lo-
cated, which is a Personal Computer with a touch
screen as well as a trackball from where the engi-
neer can carry out engine commands, adjust the
engine parameters, select the running modes, and
observe the status of the control system.
A conventional marine approved PC is also lo-
cated in the engine control room serving as a
backup unit for the MOP.
Engine Control Unit (ECU)
For redundancy purposes, the control system
comprises two ECUs operating in parallel and
performing the same task, one being a hot
standby for the other. If one of the ECUs fail, the
other unit will take over the control without any
interruption.
The ECUs perform such tasks as:
Speed governor functions, start/stop sequenc-
es, timing of fuel injection, timing of exhaust
valve activation, timing of starting valves, etc.
Continuous running control of auxiliary func-
tions handled by the ACUs
Alternative running modes and programs.
Cylinder Control Unit (CCU)
The control system includes one CCU per cyl-
inder. The CCU controls the electronic exhaust
Valve Activation (FIVA) and the Starting Air Valves
(SAV), in accordance with the commands received
from the ECU.
All the CCUs are identical, and in the event of a
failure of the CCU for one cylinder only this cylin-
der will automatically be put out of operation.
It should be noted that any electronic part could
be replaced without stopping the engine, which
will revert to normal operation immediately after
the replacement of the defective unit.
Auxiliary Control Unit (ACU)
The control of the auxiliary equipment on the en-
gine is normally divided among three ACUs so
that, in the event of a failure of one unit, there is
sufcient redundancy to permit continuous opera-
tion of the engine.
The ACUs perform the control of the auxiliary
blowers, the control of the electrically and engine
driven hydraulic oil pumps of the Hydraulic Power
Supply (HPS) unit, etc.
Engine Control System ME
MAN B&W 16.01
Page 2 of 9
MAN Diesel
MAN B&W ME/MEC engines 198 48 476.6
Engine Interface Control Unit (EICU)
The two EICUs perform such tasks as interface
with the surrounding control systems, see Fig.
16.01.01a and b. The two redundant EICU units
operate in parallel.
The EICUs are located either in the Engine Control
Room (ECR) or in the engine room.
In basic execution, the EICUs are a placed in the
Cabinet for EICUs, EoD: 4 65 601. Optionally, the
EICUs can be placed in the ECS Common Control
Cabinet, option: 4 65 602, with the ACUs, CCUs
and ECUs. See Figs. 16.01a and b.
Local Operating Panel (LOP)
In normal operating the engine can be controlled
from either the bridge or from the engine control
room.
Alternatively, the LOP can be activated. This re-
dundant control is to be considered as a substi-
tute for the previous Engine Side Control console
mounted directly onto the MC engine.
The LOP is as standard placed on the engine.
From the LOP, the basic functions are available,
such as starting, engine speed control, stopping,
reversing, and the most important engine data are
displayed.
Control Network
The MOP, the backup MOP and the MPCs are
interconnected by means of the doubled Control
Network, A and B respectively.
The maximum length of Control Network cabling
between the furthermost units on the engine and
in the Engine Control Room (an EICU or a MOP) is
160 meter.
Should the layout of the ship make longer Control
Network cabling necessary, a Control Network
Repeater must be inserted to amplify the signals
and divide the cable into segments no longer than
160 meter. For instance, where the Engine Control
Room and the engine room are located far apart.
Power Supply
Hydraulic Power Supply (HPS)
The purpose of the HPS unit is to deliver the
necessary high pressure hydraulic oil ow to the
Hydraulic Cylinder Units (HCU) on the engine at
the required pressure (approx. 300 bar) during
startup as well as in normal service.
As hydraulic medium, normal lubricating oil is
used, and it is in the standard execution taken
from the main lubricating oil system of the engine.
The HPS unit can be driven either mechanically
from the engine crankshaft, see Fig. 16.01.02.
The multiple pump conguration with standby
pumps ensures redundancy with regard to the
hydraulic power supply. The control of the engine
driven pumps and electrical pumps are divided
between the three ACUs.
The high pressure pipes between the HPS unit
and the HCU are of the double walled type, hav-
ing a leak detector. Emergency running is possible
using the outer pipe as pressure containment for
the high pressure oil supply.
The sizes and capacities of the HPS unit depend
on the engine type. Further details about the HPS
and the lubricating oil/hydraulic oil system can be
found in Chapter 8.
Supply voltage, nominal 24 V DC
Supply voltage, operational
limits
20 V - 30 V
Supply voltage, max. ripple
voltage
1 Vpp or 1 Vrms,
whichever is lowest
MAN B&W 16.01
Page 3 of 9
MAN Diesel
MAN B&W ME/MEC engines 198 79 23-5.1
A
c
t
u
a
t
o
r
s
S
e
n
s
o
r
s
A
c
t
u
a
t
o
r
s
S
e
n
s
o
r
s
On Bridge
In Engine Control Room
In Engine Room/On Engine
ECU A
EICU A EICU B
ECU B
Backup Operation Panel
MOP B
Bridge Panel
Local Operation
Panel LOP
Auxiliary
Blower 1
Auxiliary
Blower 2
ECR Panel
ACU 1
CCU
Cylinder 1
CCU
Cylinder n
ACU 3 ACU 2
SAV
Cylinder n
Main Operation Panel
MOP A
Fuel
booster
position
Cylinder 1
Exhaust
valve
position
Cylinder 1
Exhaust
valve
position
Cylinder n
Fuel
booster
position
Cylinder n
FIVA
Valve
Cylinder n
AL
Cylinder 1
SAV
Cylinder 1
AL
Cylinder n
Angle Encoders
Marker Sensor
FIVA
Valve
Cylinder 1

MM

P
u
m
p

1
M

M

M

M

M
Auxiliary
Blower 3
Auxiliary
Blower 4
P
u
m
p

2
P
u
m
p

1
P
u
m
p

2
P
u
m
p

3
P
u
m
p

4
P
u
m
p

5
Cabinet for EICU
Engine Control System Layout with Cabinet for EICU
178 61 91-2.0
Fig. 16.01.01a: Engine Control System layout with cabinet for EICU for mounting in
ECR or ER, EoD: 4 65 601
MAN B&W 16.01
Page 4 of 9
MAN Diesel
MAN B&W ME/MEC engines 198 79 23-5.1
A
c
t
u
a
t
o
r
s
S
e
n
s
o
r
s
A
c
t
u
a
t
o
r
s
S
e
n
s
o
r
s
On Bridge
In Engine Control Room
In Engine Room/On Engine
ECU A
EICU A EICU B
ECU B
Backup Operation Panel
MOP B
Bridge Panel
Local Operation
Panel LOP
Auxiliary
Blower 1
Auxiliary
Blower 2
ECR Panel
ACU 1
CCU
Cylinder 1
CCU
Cylinder n
ACU 3 ACU 2
SAV
Cylinder n
Main Operation Panel
MOP A
Fuel
booster
position
Cylinder 1
Exhaust
valve
position
Cylinder 1
Exhaust
valve
position
Cylinder n
Fuel
booster
position
Cylinder n
FIVA
Valve
Cylinder n
AL
Cylinder 1
SAV
Cylinder 1
AL
Cylinder n
Angle Encoders
Marker Sensor
FIVA
Valve
Cylinder 1

MM

P
u
m
p

1
M

M

M

M

M
Auxiliary
Blower 3
Auxiliary
Blower 4
ME ECS Common Control Cabinet
in Engine Control Room/Engine Room
P
u
m
p

2
P
u
m
p

1
P
u
m
p

2
P
u
m
p

3
P
u
m
p

4
P
u
m
p

5
Engine Control System Layout with Common Control Cabinet
178 61 76-9.1
Fig. 16.01.01b: Engine Control System layout with ECS Common Control Cabinet for mounting in
ECR or ER, option: 4 65 602
MAN B&W 16.01
Page 5 of 9
MAN Diesel
MAN B&W ME/MEC engines 198 79 24-7.0
Mechanicalhydraulic System with Hydraulic Power Supply Unit on Engine
Fig. 16.01.02: Mechanicalhydraulic System with Hydraulic Power Supply Unit on Engine, 300 bar, common supply
515 75 30-9.2.0
Main filter
To AE
Electrically
driven
pumps
Engine
driven
pumps
Safety and
accumulator block
RW
Backflushing oil
Filter unit
RU
Stepup gear
To AE
Main tank
Distributor block
Return to tank
Lubricating
and cooling
oil pipes
Alarm box
Alarm box
ME lubricator
P
T


1
2
0
4

n


Z
L
P
T


1
2
0
4

3


Z
L
Only 98 engine
Return oil
standpipe
FIVA
with pilot valve
Stepup
Return to
tank
Fuel oil drain
Fuel oil inlet
Fuel pump
Exhaust
Valve
Actuator
Exhaust valve
Fuel valves
Hydraulic piston
High pressure pipes
Umbrella
sealing
Hydraulic
piston
Activation
piston
Fuel oil outlet
X
F
AD
Oil supply to
hydraulic 'pushrod'
for exhaust valve
I
Hydraulic pushrod
Hydraulic
piston
HPS unit
M M
ZV 8204 C
ZT 8203 C
LS 8208 C
ZT 4111 C
Return to
tank
Return to
tank
LS 4112 AH
PT 12011 C
ZV 1202 B
PT 12012 C
PT 12013 C
ZV 1202 A
ZV 1243 C
P
T


1
2
0
4

2


Z
L
P
T


1
2
0
4

1


Z
L
TE 1270 I AH Y
LS 1235 AH
LS 1236 AH Z
ZT 4114 C
XC 1231 AL
The letters refer to list of Counteranges
Th item No. refer to Guidance Values Automation
MAN B&W 16.01
Page 6 of 9
MAN Diesel
MAN B&W ME/MEC engines 198 79 24-7.0
Mechanicalhydraulic System with Hydraulic Power Supply Unit in Ship
Fig. 16.01.02b: Mechanicalhydraulic System with Hydraulic Power Supply Unit in ship, 300 bar, common supply.
Example from S90/80ME-C engine
515 75 49-1.1.0
M M M M
Main filter
To AE
Safety and
accumulator block
RW
Backflushing oil
Filter unit
RU
Stepup gear
To AE
Main tank
Distributor block
Return to tank
Lubricating
and cooling
oil pipes
Alarm box
Alarm box
ME lubricator
P
T


1
2
0
4

n


Z
L P
T


1
2
0
4

3


Z
L
Return oil
standpipe
FIVA
with pilot valve
Return to
tank
Fuel oil drain
Fuel oil inlet
Fuel pump
Exhaust
Valve
Actuator
Exhaust valve
Fuel valves
Hydraulic piston
High pressure pipes
Umbrella
sealing
Hydraulic
piston
Activation
piston
Fuel oil outlet
X
F
AD
Oil supply to
hydraulic 'pushrod'
for exhaust valve
I
Hydraulic pushrod
Hydraulic
piston
HPS unit
ZV 8204 C
ZT 8203 C
LS 8208 C
ZT 4111 C
Return to
tank
Return to
tank
LS 4112 AH
PT 12011 C
PT 12012 C
PT 12013 C
ZV 1243 C
P
T


1
2
0
4

2


Z
L
P
T


1
2
0
4

1


Z
L
LS 1235 AH
LS 1236 AH Z
ZT 4114 C
XC 1231 AL
The letters refer to list of Counteranges
Th item No. refer to Guidance Values Automation
MAN B&W 16.01
Page 7 of 9
MAN Diesel
MAN B&W ME/MEC engines 198 79 259.0
To support the navigator, the vessels are
equipped with a ship control system, which in-
cludes subsystems to supervise and protect the
main propulsion engine.
Alarm system
The alarm system has no direct effect on the ECS.
The alarm alerts the operator of an abnormal con-
dition.
The alarm system is an independent system, in
general covering more than the main engine itself,
and its task is to monitor the service condition
and to activate the alarms if a normal service limit
is exceeded.
The signals from the alarm sensors can be used
for the slow down function as well as for remote
indication.
Slow down system
Some of the signals given by the sensors of the
alarm system are used for the Slow down re-
quest signal to the ECS of the main engine.
Safety system
The engine safety system is an independent sys-
tem with its respective sensors on the main en-
gine, fullling the requirements of the respective
classication society and MAN Diesel.
If a critical value is reached for one of the meas-
uring points, the input signal from the safety
system must cause either a cancellable or a
noncancellable shut down signal to the ECS.
The safety system must be compatible with the
remote control system.
Telegraph system
This system enables the navigator to transfer the
commands of engine speed and direction of rota-
tion from the Bridge, the engine control room or
the Local Operating Panel (LOP), and it provides
signals for speed setting and stop to the ECS.
The engine control room and the LOP are pro-
vided with combined telegraph and speed setting
units.
Remote Control system
The remote control system normally has two alter-
native control stations:
the bridge control
the engine control room control
The remote control system is to be delivered by
an approved supplier and it must be compatible
with the safety system.
Power Management System
The system handles the supply of electrical power
onboard, i. e. the starting and stopping of the gen-
erating sets as well as the activation / deactivation
of the main engine Shaft Generator (SG), if tted.
The normal function involves starting, synchro-
nising, phasingin, transfer of electrical load and
stopping of the generators based on the electrical
load of the grid on board.
The activation / deactivation of the SG is to be
done within the engine speed range which fulls
the specied limits of the electrical frequency.
Engine Control System Interface to Surrounding Systems
MAN B&W 16.01
Page 8 of 9
MAN Diesel
MAN B&W ME/MEC engines 198 79 259.0
Auxiliary equipment system
The input signals for Auxiliary system ready are
given partly through the Remote Control system
based on the status for:
fuel oil system
lube oil system
cooling water systems
and partly from the ECS itself:
turning gear disengaged
main starting valve open
control air valve for sealing air open
control air valve for air spring open
auxiliary blowers running
hydraulic power supply ready.
Monitoring systems
In addition to the PMI system type PT/S offline
required for the installation of the ME engine, PMI
online and CoCoSEDS can be used to improve
the monitoring of the engine.
A description of the systems can be found in
Chapter 18 of this project guide.
Instrumentation
Chapter 18 in the Project Guide for the specic
engine type includes lists of instrumentation for:
The CoCoSEDS online system
The class requirements and MAN Diesels re-
quirements for alarms, slow down and shut
down for Unattended Machinery Spaces.
MAN B&W 16.01
Page 9 of 9
MAN Diesel
MAN B&W ME/MEC engines 198 79 260.0
Service/blocked
39 38
30
34
35
ZS 1116A+B C
ZS 1117A+B C
ZV 11201 C
ZV 1121A C
PT 8501B IAC
PT 8501A IAC
ZS 1111A+B C
ZS 1112A+B C
ZV 1121B C
ZV 1114 C
ZS 1110A+B C
ZS 1109A+B C
PT 8505 AL YL
PT 8503A IALC
PT 8503B IALC
Starting air
supply 30 bar
A
41
40 Slow turning
valve
Open

1
5
x
2

1
5
x
2
Open
Main starting
valve
50
58
59
51
Starting
valves
32
36
Safety relief
valve
16x2 20x2.5 20x2.5

1
6
x
2
20x2.5

1
6
x
2
Turning gear
20
29
28
1
2
3 4 6
5
B
Control
air supply
7 bar
10
Connected to
oil mist detector
11
15
Exhaust valve
37
Pneumatic Manoeuvring Diagram
178 49 738.2
Fig. 16.01.03: Pneumatic Manoeuvring Diagram
MAN B&W
MAN Diesel
Vibration Aspects

17
MAN B&W 17.01
Page 1 of 1
MAN Diesel
198 41 405.3 MAN B&W MC/MCC, ME/MEC/MEGI/ME-B engines
Vibration Aspects
The vibration characteristics of the twostroke low
speed diesel engines can for practical purposes
be split up into four categories, and if the adequate
countermeasures are considered from the early
project stage, the inuence of the excitation sour-
ces can be minimised or fully compensated.
In general, the marine diesel engine may inuence
the hull with the following:
External unbalanced moments
These can be classied as unbalanced 1st and
2nd order external moments, which need to be
considered only for certain cylinder numbers
Guide force moments
Axial vibrations in the shaft system
Torsional vibrations in the shaft system.
The external unbalanced moments and guide force
moments are illustrated in Fig. 17.01.01.
In the following, a brief description is given of their
origin and of the proper countermeasures needed
to render them harmless.
External unbalanced moments
The inertia forces originating from the unbalanced
rotating and reciprocating masses of the engine
create unbalanced external moments although the
external forces are zero.
Of these moments, the 1st order (one cycle per revo-
lution) and the 2nd order (two cycles per revolution)
need to be considered for engines with a low num-
ber of cylinders. On 7cylinder engines, also the 4th
order external moment may have to be examined.
The inertia forces on engines with more than 6 cylin-
ders tend, more or less, to neutralise themselves.
Countermeasures have to be taken if hull resonance
occurs in the operating speed range, and if the vibra-
tion level leads to higher accelerations and/or velo ci-
ties than the guidance values given by international
standards or recommendations (for instance related
to special agreement between shipowner and ship-
yard). The natural frequency of the hull depends
on the hulls rigidity and distribution of masses,
whereas the vibration level at resonance depends
mainly on the magnitude of the external moment
and the engines position in relation to the vibration
nodes of the ship.
C C
A
B
D
A Combustion pressure
B Guide force
C Staybolt force
D Main bearing force
1st order moment vertical 1 cycle/rev.
2nd order moment, vertical 2 cycle/rev.
1st order moment, horizontal
1 cycle/rev.
Guide force moment,
H transverse Z cycles/rev.
Z is 1 or 2 times number of cylinder
Fig. 17.01.01: External unbalanced moments and guide
force moments
Guide force moment,
X transverse Z cycles/rev.
Z = 1, 2, 3 ... 11, 12, 14
178 06 828.2
MAN B&W 17.02
Page 1 of 2
MAN Diesel
198 80 02-6.0 MAN B&W Engine Selection Guide
2nd Order Moments on 4, 5 and 6-cylinder Engines
The 2nd order moment acts only in the vertical
direction. Precautions need only to be considered
for 4, 5 and 6-cylinder engines in general.
Resonance with the 2nd order moment may oc-
cur in the event of hull vibrations with more than
3 nodes. Contrary to the calculation of natural
frequency with 2 and 3 nodes, the calculation of
the 4 and 5-node natural frequencies for the hull
is a rather comprehensive procedure and often
not very accurate, despite advanced calculation
methods.
A 2nd order moment compensator comprises two
counterrotating masses running at twice the en-
gine speed.
Compensator solutions
Several solutions are available to cope with the
2nd order moment, as shown in Fig. 17.03.02, out
of which the most cost efcient one can be cho-
sen in the individual case.
The information about compensator solutions is
to be found in the Project Guide for the relevant
engine type.
Determine the need
A decision regarding the vibrational aspects and
the possible use of compensators must be taken
at the contract stage. If no experience is available
from sister ships, which would be the best basis
for deciding whether compensators are necessary
or not, it is advisable to make calculations to de-
termine which of the solutions should be applied.
If the compensator is initially omitted, measure-
ments taken during the sea trial, or later in service
and with fully loaded ship, will be able to show if a
compensator has to be tted at all.
Preparation for compensators
If no calculations are available at the contract
stage, we advise to make preparations for the t-
ting of an electrically driven moment compensator
in the steering compartment, see Section 17.03.
The information about preparation for compensa-
tors is to be found in the Project Guide for the rel-
evant engine type.
Basic design regarding compensators
The information is to be found in the Project Guide
for the relevant engine type.
The available options for 5 and 6-cylinder engines
are listed in the Extent of Delivery. For 4-cylinder
engines, the information is available on request.
Natural frequency
cycles/min.
S50MEC
S60MEC
S70MEC
S80MEC
S90MEC 150
100
50
4
n
o
d
e
3
n
o
d
e
2 n
ode
20,000 40,000 60,000
dwt
80,000
200
250
300
5

n
o
d
e
Cycles/min. *)
*) Frequency of engine moment
M2V = 2 x engine speed
Fig. 17.02.01: Statistics of vertical hull vibrations in tank-
ers and bulk carriers, example from S90-50ME-C
178 60 917.0
MAN B&W 17.02
Page 2 of 2
MAN Diesel
198 80 02-6.0 MAN B&W Engine Selection Guide
178 16 787.0
This section is only applicable for engines type
70 and smaller.
1st order moments act in both vertical and hori-
zontal direction. For our twostroke engines with
standard balancing these are of the same magni-
tudes.
For engines with ve cylinders or more, the 1st
order moment is rarely of any signicance to the
ship. It can, however, be of a disturbing magnitude
in fourcylinder engines.
Resonance with a 1st order moment may occur
for hull vibrations with 2 and/or 3 nodes. This
resonance can be calculated with reasonable ac-
curacy, and the calculation will show whether a
compensator is necessary or not on fourcylinder
engines.
A resonance with the vertical moment for the 2
node hull vibration can often be critical, whereas
the resonance with the horizontal moment occurs
at a higher speed than the nominal because of the
higher natural frequency of horizontal hull vibra-
tions.
Balancing 1st order moments
As standard, fourcylinder engines are tted with
1st order moment balancers in shape of adjust-
able counterweights, as illustrated in Fig. 17.02.02.
These can reduce the vertical moment to an insig-
nicant value (although, increasing correspond-
ingly the horizontal moment), so this resonance is
easily dealt with. A solution with zero horizontal
moment is also available.
1st order moment compensators
In rare cases, where the 1st order moment will
cause resonance with both the vertical and the
horizontal hull vibration mode in the normal speed
range of the engine, a 1st order compensator can
be introduced as an option, reducing the 1st order
moment to a harmless value.
Adjustable
counterweights
Adjustable
counterweights
Fixed
counterweights
Fixed
counterweights
Aft
Fore
Fig. 17.02.02: Examples of counterweights
Since resonance with both the vertical and the
horizontal hull vibration mode is rare, the standard
engine is not prepared for the tting of 1st order
moment compensators.
Data on 1st order moment compensators and
preparation as well as options in the Extent of De-
livery are available on request.
1st Order Moments on 4cylinder Engines
MAN B&W 17.03
Page 1 of 2
MAN Diesel
198 42 221.5 MAN B&W K98MC/MC-C/ME/ME-C, S90MC-C/ME-C,
K90MC-C/ME/ME-C, S80MC/MC-C/ME-C, K80MC-C/ME-C,
S70MC/MC-C/ME-C/ME-GI, L70MC-C/ME-C, S65ME-C/ME-GI,
S60MC/MC-C/ME-C/ME-GI/ME-B, L60MC-C/ME-C,
S50MC/MC-C/ME-B8, S46MC-C/ME-B, S42MC, S/L35MC, S26MC
178 57 45-6.0
Fig. 17.03.01: MAN Diesel 2nd order electrically driven moment compensator, separately mounted,
option: 4 31 255
If it is decided not to use chain driven moment
compensators and, furthermore, not to prepare
the main engine for compensators to be tted
later, another solution can be used, if annoying
2nd order vibrations should occur: An electrically
driven moment compensator synchronised to the
correct phase relative to the external force or mo-
ment can neutralise the excitation.
This type of compensator needs an extra seating
tted, preferably, in the steering gear room where
vibratory deections are largest and the effect of
the compensator will therefore be greatest.
The electrically driven compensator will not give
rise to distorting stresses in the hull, but it is more
expensive than the engine-mounted compensa-
tors. It does, however, offer several advantages
over the engine mounted solutions:
When placed in the steering gear room, the
compensator is not as sensitive to the position-
ing of the node as the compensators 2) and 3)
mentioned in Section 17.02.
The decision whether or not to install compen-
sators can be taken at a much later stage of a
project, since no special version of the engine
structure has to be ordered for the installation.
No preparation for a later installation nor an ex-
tra chain drive for the compensator on the fore
end of the engine is required. This saves the
cost of such preparation, often left unused.
Compensators could be retrot, even on ships
in service, and also be applied to engines with a
higher number of cylinders than is normally con-
sidered relevant, if found necessary.
The compensator only needs to be active at
speeds critical for the hull girder vibration. Thus,
it may be activated or deactivated at specied
speeds automatically or manually.
Combinations with and without moment com-
pensators are not required in torsional and axial
vibration calculations, since the electrically
driven moment compensator is not part of the
mass-elastic system of the crankshaft.
Furthermore, by using the compensator as a vi-
bration exciter a ships vibration pattern can easily
be identied without having the engine running,
e.g. on newbuildings at an advanced stage of
construction. If it is veried that a ship does not
need the compensator, it can be removed and re-
used on another ship.
It is a condition for the application of the rotating
force moment compensator that no annoying lon-
gitudinal hull girder vibration modes are excited.
Based on our present knowledge, and conrmed
by actual vibration measurements onboard a ship,
we do not expect such problems.
Further to compensating 2nd order moments,
electrically driven moment compensators are also
available for balancing other forces and moments.
The available options are listed in the Extent of
Delivery.
Electrically Driven Moment Compensator
MAN B&W 17.03
Page 2 of 2
MAN Diesel
198 42 221.5 MAN B&W K98MC/MC-C/ME/ME-C, S90MC-C/ME-C,
K90MC-C/ME/ME-C, S80MC/MC-C/ME-C, K80MC-C/ME-C,
S70MC/MC-C/ME-C/ME-GI, L70MC-C/ME-C, S65ME-C/ME-GI,
S60MC/MC-C/ME-C/ME-GI/ME-B, L60MC-C/ME-C,
S50MC/MC-C/ME-B8, S46MC-C/ME-B, S42MC, S/L35MC, S26MC
Fig. 17.03.02: Compensation of 2nd order vertical external moments
178 27 104.1
Moment compensator
Fore end, option: 4 31 213
2 2
Centre line
crankshaft
4 Node
3 Node
Compensating moment
F2C x Lnode
outbalances M2V
M2V
F2C
Node AFT
Lnode
Moment from compensator
M2C reduces M2V
M2C
M2V
3 and 4node vertical hull girder mode
Moment compensator
Aft end, option: 4 31 203
Electrically driven moment compensator
Compensating moment
F
D
x Lnode
outbalances M2V
M2V
Node Aft
L
D
n
o
d
e
F
D
2
2
MAN B&W 17.03
Page 1 of 2
MAN Diesel
198 69 781.1 MAN B&W S50MEC7/8, S50ME-B9, S40MC-C9, S40ME-B9,
S35MC-C9, S35ME-B9
178 57 45-6.0
Fig. 17.03.01: MAN Diesel 2nd order electrically driven
moment compensator, separately mounted, option: 4 31 255
If annoying 2nd order vibrations should occur:
An, an electrically driven moment compensator
synchronised to the correct phase relative to the
external force or moment can neutralise the exci-
tation.
This type of compensator needs an extra seating
tted, preferably, in the steering gear room where
vibratory deections are largest and the effect of
the compensator will therefore be greatest.
The electrically driven compensator will not give
rise to distorting stresses in the hull and it offers
several advantages over the engine mounted solu-
tions:
When placed in the steering gear room, the
compensator is not particularly sensitive to the
positioning of the node.
The decision whether or not to install compen-
sators can be taken at a much later stage of a
project, since no special version of the engine
structure has to be ordered for the installation.
Compensators could be retrot, even on ships
in service, and also be applied to engines with a
higher number of cylinders than is normally con-
sidered relevant, if found necessary.
The compensator only needs to be active at
speeds critical for the hull girder vibration. Thus,
it may be activated or deactivated at specied
speeds automatically or manually.
Combinations with and without moment com-
pensators are not required in torsional and axial
vibration calculations, since the electrically
driven moment compensator is not part of the
mass-elastic system of the crankshaft.
Furthermore, by using the compensator as a vi-
bration exciter a ships vibration pattern can easily
be identied without having the engine running,
e.g. on newbuildings at an advanced stage of
construction. If it is veried that a ship does not
need the compensator, it can be removed and re-
used on another ship.
It is a condition for the application of the rotating
force moment compensator that no annoying lon-
gitudinal hull girder vibration modes are excited.
Based on our present knowledge, and conrmed
by actual vibration measurements onboard a ship,
we do not expect such problems.
Balancing other forces and moments
Further to compensating 2nd order moments,
electrically driven moment compensators are also
available for balancing other forces and moments.
The available options are listed in the Extent of
Delivery.
Electrically Driven Moment Compensator
MAN B&W 17.03
Page 2 of 2
MAN Diesel
198 69 781.1 MAN B&W S50MEC7/8, S50ME-B9, S40MC-C9, S40ME-B9,
S35MC-C9, S35ME-B9
Fig. 17.03.02: Compensation of 2nd order vertical external moments
178 61 15-9.0
4 Node
3 Node
3 and 4node vertical hull girder mode
Electrically driven moment compensator
Compensating moment
F
D
x Lnode
outbalances M2V
M2V
Node Aft
L
D
n
o
d
e
F
D
Nodes and Compensators
MAN B&W 17.04
Page 1 of 2
MAN Diesel
198 79 90-4.0 MAN B&W ME/ME-C Engine Selection Guide
Power Related Unbalance
To evaluate if there is a risk that 1st and 2nd or-
der external moments will excite disturbing hull
vibrations, the concept Power Related Unbal-
ance (PRU) can be used as a guidance, see
Tables 17.04.01a, b and c below.
PRU =
External moment

___________

Engine power
Nm/kW
With the PRUvalue, stating the external moment
relative to the engine power, it is possible to give
an estimate of the risk of hull vibrations for a spe-
cic engine.
Based on service experience from a great number
of large ships with engines of different types and
cylinder numbers, the PRUvalues have been
classied in four groups as follows:
PRU Nm/kW Need for compensator
0 - 60 Not relevant
60 - 120 Unlikely
120 - 220 Likely
220 - Most likely
5 cyl. 6 cyl. 7 cyl. 8 cyl. 9 cyl. 10 cyl. 11 cyl. 12 cyl. 14 cyl.
S90ME-C8 5,270 kW/cyl at 78 r/min
PRU acc. to 1st order, Nm/kW N.a. 0.0 10.8 2.1 29.0 N.a. N.a. N.a. N.a.
PRU acc. to 2nd order, Nm/kW N.a. 169.7 42.2 0.0 36.9 N.a. N.a. N.a. N.a.
S80ME-C9 4,510 kW/cyl at 78 r/min
PRU acc. to 1st order, Nm/kW N.a. 0.0 7.6 2.7 20.3 N.a. N.a. N.a. N.a.
PRU acc. to 2nd order, Nm/kW N.a. 122.5 30.5 0.0 26.7 N.a. N.a. N.a. N.a.
S80ME-C8 4,180 kW/cyl at 78 r/min
PRU acc. to 1st order, Nm/kW N.a. 0.0 9.1 26.6 N.a. N.a. N.a. N.a. N.a.
PRU acc. to 2nd order, Nm/kW N.a. 142.8 35.5 0.0 N.a. N.a. N.a. N.a. N.a.
S70ME-C8 3,270 kW/cyl at 91 r/min
PRU acc. to 1st order, Nm/kW 16.0 0.0 6.8 20.0 N.a. N.a. N.a. N.a. N.a.
PRU acc. to 2nd order, Nm/kW 184.5 107.0 26.6 0.0 N.a. N.a. N.a. N.a. N.a.
S65ME-C8 2,870 kW/cyl at 95 r/min
PRU acc. to 1st order, Nm/kW 15.8 0.0 6.7 19.8 N.a. N.a. N.a. N.a. N.a.
PRU acc. to 2nd order, Nm/kW 188.2 109.1 27.1 0.0 N.a. N.a. N.a. N.a. N.a.
S60ME-C8 2,380 kW/cyl at 105 r/min
PRU acc. to 1st order, Nm/kW 13.7 0.0 5.8 17.2 N.a. N.a. N.a. N.a. N.a.
PRU acc. to 2nd order, Nm/kW 158.7 92.0 22.9 0.0 N.a. N.a. N.a. N.a. N.a.
S50ME-C8 1,660 kW/cyl at 127 r/min
PRU acc. to 1st order, Nm/kW 11.1 0.0 4.7 13.8 12.6 N.a. N.a. N.a. N.a.
PRU acc. to 2nd order, Nm/kW 127.5 74.0 18.4 0.0 16.1 N.a. N.a. N.a. N.a.
Based on external moments in layout point L
1
N.a. Not applicable
*) Available on request
Data for 4-cylinder engines (ie. for types 70 and smaller) is available on request
Table 17.04.01a: Power Related Unbalance (PRU) values in Nm/kW for S-ME/ME-C engines
MAN B&W 17.04
Page 2 of 2
MAN Diesel
198 79 90-4.0 MAN B&W ME/ME-C Engine Selection Guide
Table 17.04.01b: Power Related Unbalence (PRU) values in Nm/kW for L-ME/ME-C engines
5 cyl. 6 cyl. 7 cyl. 8 cyl. 9 cyl. 10 cyl. 11 cyl. 12 cyl. 14 cyl.
L70ME-C8 3,270 kW/cyl at 108 r/min
PRU acc. to 1st order, Nm/kW 19.3 0.0 8.2 24.1 N.a. N.a. N.a. N.a. N.a.
PRU acc. to 2nd order, Nm/kW 200.1 116.0 28.9 0.0 N.a. N.a. N.a. N.a. N.a.
L60ME-C8 2,340 kW/cyl at 123 r/min
PRU acc. to 1st order, Nm/kW 15.4 0.0 6.5 19.2 16.0 N.a. N.a. N.a. N.a.
PRU acc. to 2nd order, Nm/kW 159.6 92.5 23.0 0.0 26.4 N.a. N.a. N.a. N.a.
Based on external moments in layout point L
1
N.a. Not applicable
*) Available on request
Data for 4-cylinder engines (ie. for types 70 and smaller) is available on request
Table 17.04.01c: Power Related Unbalance (PRU) values in Nm/kW for K-ME/ME-C engines
5 cyl. 6 cyl. 7 cyl. 8 cyl. 9 cyl. 10 cyl. 11 cyl. 12 cyl. 14 cyl.
K98ME7 6,230 kW/cyl at 97 r/min
PRU acc. to 1st order, Nm/kW N.a. 0.0 14.4 6.1 20.4 15.4 2.0 0.0 5.7
PRU acc. to 2nd order, Nm/kW N.a. 188.2 46.8 0.0 16.7 14.3 2.7 0.0 0.0
K98ME-C7 6,020 kW/cyl at 104 r/min
PRU acc. to 1st order, Nm/kW N.a. 0.0 14.8 6.3 20.9 15.7 2.0 0.0 5.8
PRU acc. to 2nd order, Nm/kW N.a. 180.9 45.0 0.0 16.1 13.9 2.6 0.0 0.0
K90ME9 5,720 kW/cyl at 94 r/min
PRU acc. to 1st order, Nm/kW N.a. 0.0 10.5 1.4 28.1 18.6 1.4 0.0 N.a.
PRU acc. to 2nd order, Nm/kW N.a. 143.8 35.8 0.0 31.3 5.8 2.0 0.0 N.a.
K90ME-C9 5,730 kW/cyl at 104 r/min
PRU acc. to 1st order, Nm/kW N.a. 0.0 11.3 33.1 30.2 20.0 1.5 0.0 N.a.
PRU acc. to 2nd order, Nm/kW N.a. 148.8 37.0 0.0 32.4 6.0 2.0 0.0 N.a.
K80ME-C9 4,530 kW/cyl at 104 r/min
PRU acc. to 1st order, Nm/kW N.a. 0.0 9.6 28.0 25.6 19.6 2.8 0.0 N.a.
PRU acc. to 2nd order, Nm/kW N.a. 132.8 33.0 0.0 28.9 5.0 3.9 0.0 N.a.
K80ME-C6 3,610 kW/cyl at 104 r/min
PRU acc. to 1st order, Nm/kW N.a. 0.0 12.2 35.9 32.8 1.4 0.5 0.0 N.a.
PRU acc. to 2nd order, Nm/kW N.a. 151.9 37.8 0.0 33.1 0.9 0.8 0.0 N.a.
Based on external moments in layout point L
1
N.a. Not applicable
*) Available on request
Calculation of External Moments
In the table at the end of this chapter, the exter-
nal moments (M
1
) are stated at the speed (n
1
) and
MCR rating in point L
1
of the layout diagram.
For other speeds (n
A
), the corresponding external mo-
ments (M
A
) are calculated by means of the formula:
M
A
= M
1
x
{

n
A

__

n
1

}

2
kNm
(The tolerance on the calculated values is 2.5%).
MAN B&W 17.05
Page 1 of 3
MAN Diesel
MAN B&W MC/MCC, ME/MEC/MEGI/ME-B engines 198 42 233.4
Guide Force Moments
Top bracing level
Middle position of guide plane
Crankshaft centre line
Engine seating level
M
x
DistX
Cyl.X
X
L
x
L
L
z
Xtype Htype
L
x
L
Z
M
H
L
z
178 06 816.4
Fig. 17.05.01: Htype and Xtype guide force moments
The socalled guide force moments are caused
by the transverse reaction forces acting on the
crossheads due to the connecting rod/crankshaft
mechanism. These moments may excite engine
vibrations, moving the engine top athwartships
and causing a rocking (excited by Hmoment) or
twisting (excited by Xmoment) movement of the
engine as illustrated in Fig. 17.05.01.
The guide force moments corresponding to the
MCR rating (L
1
) are stated in Table 17.07.01.
Top bracing
The guide force moments are harmless except
when resonance vibrations occur in the engine/
double bottom system.
As this system is very difcult to calculate with the
necessary accuracy, MAN Diesel strongly recom-
mend, as standard, that top bracing is installed
between the engines upper platform brackets
and the casing side.
The vibration level on the engine when installed in
the vessel must comply with MAN Diesel vibration
limits as stated in Fig. 17.05.02.
We recommend using the hydraulic top bracing
which allow adjustment to the loading conditions
of the ship. Mechanical top bracings with stiff
connections are available on request.
With both types of top bracing, the above-men-
tioned natural frequency will increase to a level
where resonance will occur above the normal en-
gine speed. Details of the top bracings are shown
in Chapter 05.
Denition of Guide Force Moments
Over the years it has been discussed how to de-
ne the guide force moments. Especially now that
complete FEMmodels are made to predict hull/
engine interaction, the propeller denition of these
moments has become increasingly important.
Htype Guide Force Moment (M
H
)
Each cylinder unit produces a force couple con-
sisting of:
1. A force at crankshaft level
2. Another force at crosshead guide level. The po-
sition of the force changes over one revolution
as the guide shoe reciprocates on the guide.
MAN B&W 17.05
Page 2 of 3
MAN Diesel
MAN B&W MC/MCC, ME/MEC/MEGI/ME-B engines 198 42 233.4

5x10
1
mm/s
1 mm/s
10 mm/s
10
2
mm/s
5x10
2
mm/s
60 100 1.000 6.000 c/min
1
0

3
m
m
1
0

2
m
m
1
0

1
m
m
1
0
5

m
m
/
s 2
1
0
4

m
m
/
s 2
1
0
3

m
m
/
s 2
D
i
s
p
l
a
c
e
m
e
n
t
A
c
c
e
l
e
r
a
t
i
o
n

1
0

m
m
/
s 2
1
0
2

m
m
/
s 2
1

m
m
1
0

m
m
Velocity

2
m
m
50mm/s

1
0
m
/
s 2

1
m
m
25mm/s
1 Hz 10 Hz 100 Hz
Frequency
Zone : Acceptable
Zone : Vibration will not damage the main engine, however,
under adverse conditions, annoying/harmful vibration
responses may appear in the connected structures
Zone : Not acceptable
078 81 27-6.1
Fig.17.05.02: Vibration limits
Vibration Limits Valid for Single Order Harmonics
MAN B&W 17.05
Page 3 of 3
MAN Diesel
MAN B&W ME/ME-C engines 198 45 170.7
As the deection shape for the Htype is equal
for each cylinder, the N
th
order Htype guide force
moment for an Ncylinder engine with regular r-
ing order is:
N x M
H(one cylinder)
For modelling purposes, the size of the forces in
the force couple is:
Force = M
H
/L [kN]
where L is the distance between crankshaft level
and the middle position of the crosshead guide
(i.e. the length of the connecting rod).
As the interaction between engine and hull is at
the engine seating and the top bracing positions,
this force couple may alternatively be applied in
those positions with a vertical distance of (L
Z
).
Then the force can be calculated as:
Force
Z
= M
H
/L
Z
[kN]
Any other vertical distance may be applied so as
to accomodate the actual hull (FEM) model.
The force couple may be distributed at any
number of points in the longitudinal direction. A
reasonable way of dividing the couple is by the
number of top bracing and then applying the forc-
es at those points.
Force
Z, one point
= Force
Z, total
/N
top bracing, total
[kN]
Xtype Guide Force Moment (M
X
)
The Xtype guide force moment is calculated
based on the same force couple as described
above. However, as the deection shape is twist-
ing the engine, each cylinder unit does not con-
tribute with an equal amount. The centre units
do not contribute very much whereas the units at
each end contributes much.
A socalled Bimoment can be calculated (Fig.
17.05.01):
Bimoment = [forcecouple(cyl.X) x distX]
in kNm
2
The Xtype guide force moment is then dened
as:
M
X
= BiMoment/L kNm
For modelling purpose, the size of the four (4)
forces can be calculated:
Force = M
X
/L
X
[kN]
where:
L
X
is the horizontal length between force points.
Similar to the situation for the Htype guide force
moment, the forces may be applied in positions
suitable for the FEM model of the hull. Thus the
forces may be referred to another vertical level
L
Z
above the crankshaft centre line. These forces
can be calculated as follows:
Force
Z, one point
=
M
x
x L

_____

L x L
[kN]
In order to calculate the forces, it is necessary
to know the lengths of the connecting rods = L,
which are:
Engine Type L in mm
K98ME6/7 3,220
K98MEC6/7 3,090
S90MEC7/8 3,270
K90ME9 3,320
K90ME-C9 3,120
K90ME-C6 3,159
S80MEC9 3,450
S80MEC7/8 3,280
K80MEC9 2,975
K80MEC6 2,920
S70ME-C7/8 2,870
L70MEC7/8 2,660
S65MEC8 2,730
S60MEC7/8 2,460
L60MEC7/8 2,280
S50MEC7/8 2,050
MAN B&W 17.06
Page 1 of 2
MAN Diesel
198 42 245.4 MAN B&W MC/MC-C, ME/ME-C/GI, ME-B engines
When the crank throw is loaded by the gas pressure
through the connecting rod mechanism, the arms of
the crank throw deect in the axial direction of the
crankshaft, exciting axial vibrations. Through the thrust
bearing, the system is connected to the ships hull.
Generally, only zeronode axial vibrations are of
interest. Thus the effect of the additional bending
stresses in the crankshaft and possible vibrations of
the ship`s structure due to the reaction force in the
thrust bearing are to be consideraed.
An axial damper is tted as standard on all engines, min-
imising the effects of the axial vibrations, EoD: 4 31 111.

Torsional Vibrations
The reciprocating and rotating masses of the engine
including the crankshaft, the thrust shaft, the inter-
mediate shaft(s), the propeller shaft and the propeller
are for calculation purposes considered a system of
rotating masses (inertias) interconnected by torsional
springs. The gas pressure of the engine acts through
the connecting rod mechanism with a varying torque
on each crank throw, exciting torsional vibration in
the system with different frequencies.
In general, only torsional vibrations with one and
two nodes need to be considered. The main critical
order, causing the largest extra stresses in the shaft
line, is normally the vibration with order equal to the
number of cylinders, i.e., six cycles per revolution on
a six cylinder engine. This resonance is positioned at
the engine speed corresponding to the natural tor-
sional frequency divided by the number of cylinders.
The torsional vibration conditions may, for certain
installations require a torsional vibration damper, op-
tion: 4 31 105.
Plants with 11 or 12-cylinder engines type 98-80 re-
quire a torsional vibration damper.
Based on our statistics, this need may arise for the
following types of installation:
Plants with controllable pitch propeller
Plants with unusual shafting layout and for special
owner/yard requirements
Plants with 8cylinder engines.
The socalled QPT (Quick Passage of a barred speed
range Technique), is an alternative to a torsional
vibration damper, on a plant equipped with a control-
lable pitch propeller. The QPT could be implemented
in the governor in order to limit the vibratory stresses
during the passage of the barred speed range.
The application of the QPT, option: 4 31 108, has to
be decided by the engine maker and MAN Diesel
based on nal torsional vibration calculations.
Sixcylinder engines, require special attention. On
account of the heavy excitation, the natural frequen-
cy of the system with one-node vibration should
be situated away from the normal operating speed
range, to avoid its effect. This can be achieved by
changing the masses and/or the stiffness of the
system so as to give a much higher, or much lower,
natural frequency, called undercritical or overcritical
running, respectively.
Owing to the very large variety of possible shafting
arrangements that may be used in combination with
a specic engine, only detailed torsional vibration cal-
culations of the specic plant can determine whether
or not a torsional vibration damper is necessary.
Undercritical running
The natural frequency of the one-node vibration is
so adjusted that resonance with the main critical
order occurs about 3545% above the engine speed
at specied MCR.
Such undercritical conditions can be realised by
choosing a rigid shaft system, leading to a relatively
high natural frequency.
The characteristics of an undercritical system are
normally:
Relatively short shafting system
Probably no tuning wheel
Turning wheel with relatively low inertia
Large diameters of shafting, enabling the use of
shafting material with a moderate ultimate tensile
strength, but requiring careful shaft alignment,
(due to relatively high bending stiffness)
Without barred speed range.
Axial Vibrations
MAN B&W 17.06
Page 2 of 2
MAN Diesel
198 42 269.3 MAN B&W MC/MC-C, ME/ME-C/MEB/GI engines
When running undercritical, signicant varying
torque at MCR conditions of about 100150% of
the mean torque is to be expected.
This torque (propeller torsional amplitude) induces
a signicant varying propeller thrust which, under
adverse conditions, might excite annoying longi-
tudinal vibrations on engine/double bottom and/or
deck house.
The yard should be aware of this and ensure that
the complete aft body structure of the ship, in-
cluding the double bottom in the engine room, is
designed to be able to cope with the described
phenomena.
Overcritical running
The natural frequency of the onenode vibration
is so adjusted that resonance with the main criti-
cal order occurs about 3070% below the engine
speed at specied MCR. Such overcritical con-
ditions can be realised by choosing an elastic
shaft system, leading to a relatively low natural
frequency.
The characteristics of overcritical conditions are:
Tuning wheel may be necessary on crankshaft
fore end
Turning wheel with relatively high inertia
Shafts with relatively small diameters, requiring
shafting material with a relatively high ultimate
tensile strength
With barred speed range, EoD: 4 07 015, of
about 10% with respect to the critical engine
speed.
Torsional vibrations in overcritical conditions may,
in special cases, have to be eliminated by the use
of a torsional vibration damper.
Overcritical layout is normally applied for engines
with more than four cylinders.
Please note:
We do not include any tuning wheel or torsional
vibration damper in the standard scope of supply,
as the proper countermeasure has to be found af-
ter torsional vibration calculations for the specic
plant, and after the decision has been taken if and
where a barred speed range might be acceptable.
For further information about vibration aspects,
please refer to our publications:
An Introduction to Vibration Aspects
Vibration Characteristics of Two-stroke Engines
The publications are available at
www.mandieselturbo.com under Products
Marine Engines & Systems Low Speed
Technical Papers.
Critical Running
MAN B&W
Page 1 of 1
MAN Diesel
This section is available on request
for
K98ME7, S80ME-C8
as well as for
S60ME-B8, S46ME-B8
External Forces and Moments
198 80 01-4.0
17.07
MAN B&W K98ME7, S80ME-C8,
S60ME-B8, S46ME-B8
MAN B&W 17.07
Page of
MAN Diesel
MAN B&W K98ME-C7 198 57 38-0.1
External Forces and Moments, K98ME-C7 Layout point L
1
- SFOC
Table 17.07.01
No of cylinder : 6 7 8 9 0 2 4
Firing type :
-5-3-4-
2-6
-7-2-5-4-
3-6
-8-3-4-7-
2-5-6
-6-7-3-5-
8-2-4-9
-8-7-3-
5-9-4-2-
0-6
-5--6-
2-7-9-4-3-
8-0
-8-2-4-
2-9-0-5-
3-7--6
-9-3-8-
4-3-0-
4-6-2-7-
-2-5
External forces [kN] :
. Order : Horizontal 0 0 0 9 9 2 0 0
. Order : Vertical 0 0 0 9 9 2 0 0
2. Order : Vertical 0 0 0 20 3 0 0
4. Order : Vertical 0 0 0 58 46 60 0 0
6. Order : Vertical 2 0 0 3 3 0 0
External moments [kNm] :
. Order : Horizontal a) 0 624 303 ,35 948 34 0 490
. Order : Vertical a) 0 624 303 ,35 948 34 0 490
2. Order : Vertical 6,540 c) ,899 0 873 840 70 0 0
4. Order : Vertical 267 758 308 378 63 680 533 0
6. Order : Vertical 0 0 59 29 4 0 0
Guide force H-moments in [kNm] :
x No. of cyl. 2,098 ,534 ,00 545 92 64 205 228
2 x No. of cyl. 02 4 3 - - - - -
3 x No. of cyl. - - - - - - - -
Guide force X-moments in [kNm] :
. Order : 0 35 53 573 580 68 0 247
2. Order : 0 29 0 3 48 3 0 0
3. Order : ,436 ,57 2,309 2,728 3,284 3,976 4,975 670
4. Order : ,383 3,929 ,597 ,960 3,007 3,524 2,765 0
5. Order : 0 34 4,907 ,86 93 3,28 0 34
6. Order : 0 53 0 3,380 ,694 244 0 0
7. Order : 0 0 6 583 2,430 257 0 36
8. Order : 270 2 0 4 254 ,584 539 0
9. Order : 352 39 5 6 83 23 ,220 359
0. Order : 75 22 0 97 3 53 0 0
. Order : 0 34 97 77 7 222 0 57
2. Order : 0 0 39 35 6 77 0 0
3. Order : 0 2 23 49 33 6 0 2
4. Order : 32 0 0 64 55 25 0 0
5. Order : 80 2 23 39 58 277 2
6. Order : 28 8 0 6 0 53 56 0
a) st order moments are, as standard, balanced so as to obtain equal values for horizontal and vertical moments for
all cylinder numbers.
c) 6-cylinder engines can be ftted with 2nd order moment compensators on the aft and fore end, reducing the 2nd
order external moment.
MAN B&W 17.07
Page of
MAN Diesel
MAN B&W S90ME-C8 198 60 36-3.1
No of cylinder : 6 7 8 9
Firing type : -5-3-4-2-6 -7-2-5-4-3-6 -8-3-4-7-2-5-6 -6-7-3-5-8-2-4-9
External forces [kN] :
. Order : Horizontal 0 0 0 0
. Order : Vertical 0 0 0 0
2. Order : Vertical 0 0 0 0
4. Order : Vertical 0 0 0 0
6. Order : Vertical 28 0 0 0
External moments [kNm] :
. Order : Horizontal a) 0 398 88 ,374
. Order : Vertical a) 0 398 88 ,374
2. Order : Vertical 5,370 c) ,559 0 ,753
4. Order : Vertical 362 ,027 47 520
6. Order : Vertical 0 2 0 32
Guide force H-moments in [kNm] :
x No. of cyl. 2,900 2,43 ,523 958
2 x No. of cyl. 3 39 4 -
3 x No. of cyl. - - - -
Guide force X-moments in [kNm] :
. Order : 0 30 68 ,069
2. Order : 736 24 0 240
3. Order : ,424 ,557 2,36 2,790
4. Order : ,45 4,23 ,675 2,089
5. Order : 0 388 5,655 ,926
6. Order : 0 63 0 4,76
7. Order : 0 0 9 70
8. Order : 323 25 0 86
9. Order : 469 52 3 6
0. Order : 08 306 0 29
. Order : 0 66 246 9
2. Order : 0 9 37 63
3. Order : 0 2 27 43
4. Order : 34 0 0 49
5. Order : 82 2 60
6. Order : 30 9 0 0
External Forces and Moments, S90ME-C8 Layout point L
1
- SFOC
Table 17.07.01
a) st order moments are, as standard, balanced so as to obtain equal values for horizontal and vertical moments for
all cylinder numbers.
c) 6-cylinder engines can be ftted with 2nd order moment compensators on the aft and fore end, reducing the 2nd
order external moment.
MAN B&W 17.07
Page of
MAN Diesel
MAN B&W K90ME9 198 60 40-9.1
External Forces and Moments, K90ME9 Layout point L
1
- SFOC
Table 17.07.01
a) st order moments are, as standard, balanced so as to obtain equal values for horizontal and vertical moments for
all cylinder numbers.
c) 6-cylinder engines can be ftted with 2nd order moment compensators on the aft and fore end, reducing the 2nd
order external moment.
No of cylinder : 6 7 8 9 0 2
Firing type : -5-3-4-2-6
-7-2-5-4-
3-6
-8-3-4-7-
2-5-6
-6-7-3-5-
8-2-4-9
-8-7-3-5-
9-4-2-0-6
-5--6-
2-7-9-4-3-
8-0
-8-2-4-2-
9-0-5-3-7-
-6
External forces [kN] :
. Order : Horizontal 0 0 0 0 3 2 0
. Order : Vertical 0 0 0 0 3 2 0
2. Order : Vertical 0 0 0 0 52 3 0
4. Order : Vertical 0 0 0 0 53 68 0
6. Order : Vertical 7 0 0 0 5 4 0
External moments [kNm] :
. Order : Horizontal a) 0 49 62 ,445 ,062 88 0
. Order : Vertical a) 0 49 62 ,445 ,062 88 0
2. Order : Vertical 4,935 c) ,433 0 ,6 333 23 0
4. Order : Vertical 254 722 294 366 564 662 508
6. Order : Vertical 0 0 73 36 6 0
Guide force H-moments in [kNm] :
x No. of cyl. 2,400 ,772 ,259 738 239 88 208
2 x No. of cyl. 04 2 26 - - - -
3 x No. of cyl. - - - - - - -
Guide force X-moments in [kNm] :
. Order : 0 260 38 898 660 55 0
2. Order : 363 05 0 8 24 9 0
3. Order : ,209 ,322 ,998 2,402 2,94 3,45 4,269
4. Order : ,85 3,368 ,368 ,706 2,63 3,085 2,370
5. Order : 0 30 4,458 ,494 88 2,794 0
6. Order : 0 48 0 3,89 ,564 233 0
7. Order : 0 0 4 28 2,258 245 0
8. Order : 243 9 0 65 225 ,453 486
9. Order : 329 37 47 77 200 ,62
0. Order : 73 208 0 9 52 0
. Order : 0 2 83 4 66 204 0
2. Order : 0 8 3 38 50 63 0
3. Order : 0 2 04 35 2 6 0
4. Order : 27 0 0 38 32 07 0
5. Order : 68 2 0 35 35 38 240
6. Order : 24 7 0 8 98 36 49
MAN B&W 17.07
Page of
MAN Diesel
MAN B&W K90ME-C9 198 60 37-5.1
External Forces and Moments, K90ME-C9 Layout point L
1
- SFOC
Table 17.07.01
a) st order moments are, as standard, balanced so as to obtain equal values for horizontal and vertical moments for
all cylinder numbers.
c) 6-cylinder engines can be ftted with 2nd order moment compensators on the aft and fore end, reducing the 2nd
order external moment.
No of cylinder : 6 7 8 9 0 2
Firing type : -5-3-4-2-6
-7-2-5-4-
3-6
-8-3-4-7-
2-5-6
-6-7-3-5-
8-2-4-9
-8-7-3-5-
9-4-2-0-6
-5--6-
2-7-9-4-3-
8-0
-8-2-4-2-
9-0-5-3-7-
-6
External forces [kN] :
. Order : Horizontal 0 0 0 0 22 2 0
. Order : Vertical 0 0 0 0 22 2 0
2. Order : Vertical 0 0 0 0 54 3 0
4. Order : Vertical 0 0 0 0 5 65 0
6. Order : Vertical 5 0 0 0 4 4 0
External moments [kNm] :
. Order : Horizontal a) 0 452 ,58 ,560 ,47 95 0
. Order : Vertical a) 0 452 ,58 ,560 ,47 95 0
2. Order : Vertical 5,8 c) ,486 0 ,670 345 28 0
4. Order : Vertical 243 69 28 350 540 633 486
6. Order : Vertical 0 0 65 32 5 0
Guide force H-moments in [kNm] :
x No. of cyl. 2,26 ,578 ,24 652 25 77 20
2 x No. of cyl. - 9 2 - - - -
3 x No. of cyl. - - - - - - -
Guide force X-moments in [kNm] :
. Order : 0 252 844 868 638 53 0
2. Order : 54 45 0 50 0 4 0
3. Order : ,064 ,64 ,492 2,5 2,566 3,007 3,759
4. Order : ,27 3,202 ,30 ,622 2,50 2,932 2,253
5. Order : 0 286 3,583 ,46 78 2,648 0
6. Order : 0 45 0 3,006 ,474 29 0
7. Order : 0 0 96 2 2,39 233 0
8. Order : 23 8 0 6 23 ,38 462
9. Order : 309 35 3 45 73 88 ,093
0. Order : 70 99 0 9 45 0
. Order : 0 2 55 4 66 204 0
2. Order : 0 8 32 42 52 65 0
3. Order : 0 2 9 36 5 6 0
4. Order : 28 0 0 40 39 2 0
5. Order : 7 2 7 4 37 44 250
6. Order : 25 7 0 8 0 39 50
MAN B&W 17.07
Page of
MAN Diesel
MAN B&W S80ME-C9 198 54 75-4.1
External Forces and Moments, S80ME-C9 Layout point L
1
- SFOC (Mode: ECON)
a) st order moments are, as standard, balanced so as to obtain equal values for horizontal and vertical moments for
all cylinder numbers.
c) 6-cylinder engines can be ftted with 2nd order moment compensators on the aft and fore end, reducing the 2nd
order external moment.
No of cylinder : 6 7 8 9
Firing type : -5-3-4-2-6 -7-2-5-4-3-6 -8-3-4-7-2-5-6 -6-7-3-5-8-2-4-9
External forces [kN] :
. Order : Horizontal. 0 0 0 0
. Order : Vertical. 0 0 0 0
2. Order : Vertical 0 0 0 0
4. Order : Vertical 0 0 0 0
6. Order : Vertical 23 0 0 0
External moments [kNm] :
. Order : Horizontal. a) 0 239 98 823
. Order : Vertical. a) 0 239 98 823
2. Order : Vertical 3,34 c) 962 0 ,082
4. Order : Vertical 236 672 273 340
6. Order : Vertical 0 0 93
Guide force Hmoments in [kNm] :
x No. of cyl. 2,537 ,872 ,323 83
2 x No. of cyl. - - 43 -
3 x No. of cyl. - - - -
Guide force Xmoments in [kNm] :
. Order : 0 209 86 722
2. Order : 689 200 0 225
3. Order : ,85 ,296 ,98 2,377
4. Order : ,04 2,882 ,7 ,460
5. Order : 0 268 4,007 ,328
6. Order : 0 44 0 2,953
7. Order : 0 0 7
8. Order : 22 7 0 59
9. Order : 34 35 4 49
0. Order : 72 203 0 9
. Order : 0 6 78 3
2. Order : 0 7 30 34
3. Order : 0 2 07 35
4. Order : 27 0 0 39
5. Order : 68 2 36
6. Order : 24 7 0 8
Table 17.07.01
MAN B&W 17.07
Page of
MAN Diesel
MAN B&W K80ME-C9 198 55 92-7.2
External Forces and Moments, K80ME-C9 Layout point L
1
- SFOC
a) st order moments are, as standard, balanced so as to obtain equal values for horizontal and vertical moments for
all cylinder numbers.
c) 6-cylinder engines can be ftted with 2nd order moment compensators on the aft and fore end, reducing the 2nd
order external moment.
Table 17.07.01
No of cylinder : 6 7 8 9 0 2
Firing type : -5-3-4-2-6
-7-2-5-4-
3-6
-8-3-4-7-
2-5-6
-6-7-3-5-
8-2-4-9
-8-7-3-5-
9-4-2-0-6
-5--6-
2-7-9-4-3-
8-0
-8-2-4-2-
9-0-5-3-7-
-6
External forces [kN] :
. Order : Horizontal 0 0 0 0 9 0
. Order : Vertical 0 0 0 0 9 0
2. Order : Vertical 0 0 0 0 42 2 0
4. Order : Vertical 0 0 0 0 44 56 0
6. Order : Vertical 4 0 0 0 4 3 0
External moments [kNm] :
. Order : Horizontal a) 0 303 ,06 ,045 888 4 0
. Order : Vertical a) 0 303 ,06 ,045 888 4 0
2. Order : Vertical 3,6 ,048 0 ,79 228 94 0
4. Order : Vertical 9 54 220 274 427 502 38
6. Order : Vertical 0 0 49 28 4 0
Guide force H-moments in [kNm] :
x No. of cyl. ,785 ,304 928 543 69 49 209
2 x No. of cyl. 05 4 5 - - - -
3 x No. of cyl. - - - - - - -
Guide force X-moments in [kNm] :
. Order : 0 88 630 648 55 87 0
2. Order : 259 75 0 84 6 4 0
3. Order : 856 937 ,200 ,483 2,090 2,449 3,059
4. Order : 873 2,480 ,008 ,256 ,955 2,300 ,745
5. Order : 0 224 2,84 ,2 49 2,093 0
6. Order : 0 36 0 2,080 ,88 8 0
7. Order : 0 0 75 94 ,692 87 0
8. Order : 80 4 0 48 65 ,090 360
9. Order : 244 27 24 0 57 49 870
0. Order : 52 48 0 4 0 09 0
. Order : 0 96 23 53 65 0
2. Order : 0 8 3 22 52 65 0
3. Order : 0 2 9 36 7 6 0
4. Order : 25 0 0 36 27 02 0
5. Order : 63 2 6 0 34 30 226
6. Order : 22 6 0 7 92 26 45
MAN B&W 17.07
Page of
MAN Diesel
MAN B&W K80ME-C6 198 39 39-4.4
A
v
a
i
l
a
b
l
e

o
n

r
e
q
u
e
s
t
External Forces and Moments, K80ME-C6 Layout point L
1
- SFOC
a) st order moments are, as standard, balanced so as to obtain equal values for horizontal and vertical moments for
all cylinder numbers.
c) 6-cylinder engines can be ftted with 2nd order moment compensators on the aft and fore end, reducing the 2nd
order external moment.
Table 17.07.01
No of cylinder : 6 7 8 9 0 2
Firing type : -5-3-4-2-6
-7-2-5-4-
3-6
-8-3-4-7-
2-5-6
-6-7-3-5-
8-2-4-9
-8-7-3-5-
9-4-2-0-6
-5--6-
2-7-9-4-3-
8-0
-8-2-4-2-
9-0-5-3-7-
-6
External forces [kN] :
. Order : Horizontal 0 0 0 0 0
. Order : Vertical 0 0 0 0 0
2. Order : Vertical 0 0 0 0 0 2 0
4. Order : Vertical 0 0 0 0 47 38 0
6. Order : Vertical 8 0 0 0 0 2 0
External moments [kNm] :
. Order : Horizontal a) 0 309 ,037 ,066 49 9 0
. Order : Vertical a) 0 309 ,037 ,066 49 9 0
2. Order : Vertical 3,288 c) 954 0 ,073 32 33 0
4. Order : Vertical 38 393 60 99 278 357 276
6. Order : Vertical 0 0 0 29 2 2 0
Guide force H-moments in [kNm] :
x No. of cyl. 962 647 359 84 28 98
2 x No. of cyl. - - - - - -
3 x No. of cyl. - - - - - -
Guide force X-moments in [kNm] :
. Order : 62 544 559 26 0 0
2. Order : 33 0 37 0
3. Order : 882 ,30 ,397 ,737 2,26 2,828
4. Order : 2,39 869 ,084 ,5 ,944 ,505
5. Order : 8 2,273 898 358 ,673 0
6. Order : 28 0 ,659 ,229 36 0
7. Order : 0 60 76 ,398 43 0
8. Order : 0 36 50 82 273
9. Order : 20 7 0 58 06 64
0. Order : 5 0 29 83 0
. Order : 90 6 0 5 5 0
2. Order : 8 32 25 57 65 0
3. Order : 2 95 37 57 6 0
4. Order : 0 0 37 62 03 0
5. Order : 2 6 05 53 22 23
6. Order : 6 0 7 65 2 40
MAN B&W 17.07
Page 1 of 1
MAN Diesel
MAN B&W S70ME-C8/-GI 198 60 38-7.1
External Forces and Moments, S70ME-C8/-GI Layout point L
1
- SFOC
Table 17.07.01
a) 1st order moments are, as standard, balanced so as to obtain equal values for horizontal and vertical moments for
all cylinder numbers.
c) 5 and 6-cylinder engines can be tted with 2nd order moment compensators on the aft and fore end, reducing the
2nd order external moment.
No of cylinder : 5 6 7 8
Firing type : 1-4-3-2-5 1-5-3-4-2-6 1-7-2-5-4-3-6 1-8-3-4-7-2-5-6
External forces [kN] :
1. Order : Horizontal 0 0 0 0
1. Order : Vertical 0 0 0 0
2. Order : Vertical 0 0 0 0
4. Order : Vertical 0 0 0 0
6. Order : Vertical 0 15 0 0
External moments [kNm] :
1. Order : Horizontal a) 261 0 156 522
1. Order : Vertical a) 261 0 156 522
2. Order : Vertical 3,016 c) 2,098 c) 609 0
4. Order : Vertical 18 141 402 163
6. Order : Vertical 1 0 1 0
Guide force H-moments in [kNm] :
1 x No. of cyl. 2,077 1,536 1,144 822
2 x No. of cyl. 172 70 80 82
3 x No. of cyl. 55 - - -
Guide force X-moments in [kNm] :
1. Order : 226 0 134 451
2. Order : 678 472 137 0
3. Order : 485 876 958 1,228
4. Order : 87 670 1,905 774
5. Order : 0 0 173 2,173
6. Order : 48 0 28 0
7. Order : 337 0 0 61
8. Order : 212 148 11 0
9. Order : 11 214 24 21
10. Order : 0 49 140 0
11. Order : 4 0 81 104
12. Order : 24 0 5 19
13. Order : 22 0 1 55
14. Order : 2 16 0 0
15. Order : 0 41 1 4
16. Order : 2 15 4 0
MAN B&W 17.07
Page of
MAN Diesel
MAN B&W L70ME-C8 198 60 39-9.0
External Forces and Moments, L70ME-C8 Layout point L
1
- SFOC
Table 17.07.01
a) st order moments are, as standard, balanced so as to obtain equal values for horizontal and vertical moments for
all cylinder numbers.
c) 5 and 6-cylinder engines can be ftted with 2nd order moment compensators on the aft and fore end, reducing the
2nd order external moment.
No of cylinder : 5 6 7 8
Firing type : -4-3-2-5 -5-3-4-2-6 -7-2-5-4-3-6 -8-3-4-7-2-5-6
External forces [kN] :
. Order : Horizontal 0 0 0 0
. Order : Vertical 0 0 0 0
2. Order : Vertical 0 0 0 0
4. Order : Vertical 0 0 0 0
6. Order : Vertical 0 0 0
External moments [kNm] :
. Order : Horizontal a) 35 0 88 630
. Order : Vertical a) 35 0 88 630
2. Order : Vertical 3,272 c) 2,276 c) 66 0
4. Order : Vertical 6 24 353 43
6. Order : Vertical 0 0
Guide force H-moments in [kNm] :
x No. of cyl. ,667 ,209 903 654
2 x No. of cyl. 39 75 77 73
3 x No. of cyl. 5 - - -
Guide force X-moments in [kNm] :
. Order : 20 0 25 49
2. Order : 337 235 68 0
3. Order : 34 67 675 865
4. Order : 76 586 ,664 676
5. Order : 0 0 50 ,882
6. Order : 40 0 24 0
7. Order : 287 0 0 52
8. Order : 82 27 0 0
9. Order : 9 8 20 8
0. Order : 0 43 22 0
. Order : 4 0 80 03
2. Order : 28 0 6 22
3. Order : 24 0 62
4. Order : 2 7 0 0
5. Order : 0 4 4
6. Order : 2 4 4 0
MAN B&W 17.07
Page 1 of 1
MAN Diesel
MAN B&W S65ME-C8/-GI 198 49 04-0.3
External Forces and Moments, S65ME-C8/-GI Layout point L
1
- SFOC
Table 17.07.01
a) 1st order moments are, as standard, balanced so as to obtain equal values for horizontal and vertical moments for
all cylinder numbers.
c) 5 and 6-cylinder engines can be tted with 2nd order moment compensators on the aft and fore end, reducing the
2nd order external moment.
No of cylinder : 5 6 7 8
Firing type : 1-4-3-2-5 1-5-3-4-2-6 1-7-2-5-4-3-6 1-8-3-4-7-2-5-6
External forces [kN] :
1. Order : Horizontal 0 0 0 0
1. Order : Vertical 0 0 0 0
2. Order : Vertical 0 0 0 0
4. Order : Vertical 0 0 0 0
6. Order : Vertical 0 16 0 0
External moments [kNm] :
1. Order : Horizontal a) 227 0 135 454
1. Order : Vertical a) 227 0 135 454
2. Order : Vertical 2,699 c) 1,877 c) 545 0
4. Order : Vertical 18 134 380 155
6. Order : Vertical 1 0 1 0
Guide force H-moments in [kNm] :
1 x No. of cyl. 1,799 1,322 971 699
2 x No. of cyl. 143 70 80 82
3 x No. of cyl. 55 - - -
Guide force X-moments in [kNm] :
1. Order : 187 0 111 374
2. Order : 448 311 90 0
3. Order : 302 547 598 766
4. Order : 69 532 1,511 614
5. Order : 0 0 144 1,803
6. Order : 39 0 23 0
7. Order : 274 0 0 49
8. Order : 173 120 9 0
9. Order : 9 173 19 17
10. Order : 0 39 112 0
11. Order : 3 0 68 87
12. Order : 23 0 5 18
13. Order : 21 0 1 53
14. Order : 2 16 0 0
15. Order : 0 40 1 4
16. Order : 2 14 4 0
MAN B&W 17.07
Page 1 of 1
MAN Diesel
MAN B&W S60ME-C8/-GI 198 70 23-6.1
External Forces and Moments, S60ME-C8/-GI Layout point L
1
- SFOC
a) 1st order moments are, as standard, balanced so as to obtain equal values for horizontal and vertical moments for
all cylinder numbers.
c) 5 and 6-cylinder engines can be tted with 2nd order moment compensators on the aft and fore end, reducing the
2nd order external moment.
Table 17.07.01
No of cylinder : 5 6 7 8
Firing type : 1-4-3-2-5 1-5-3-4-2-6 1-7-2-5-4-3-6 1-8-3-4-7-2-5-6
External forces [kN] :
1. Order : Horizontal 0 0 0 0
1. Order : Vertical 0 0 0 0
2. Order : Vertical 0 0 0 0
4. Order : Vertical 0 0 0 0
6. Order : Vertical 0 11 0 0
External moments [kNm] :
1. Order : Horizontal a) 163 0 97 326
1. Order : Vertical a) 163 0 97 326
2. Order : Vertical 1,884 c) 1,311 c) 380 0
4. Order : Vertical 11 88 251 102
6. Order : Vertical 1 0 0 0
Guide force H-moments in [kNm] :
1 x No. of cyl. 1,296 962 721 519
2 x No. of cyl. 112 44 49 51
3 x No. of cyl. 34 - - -
Guide force X-moments in [kNm] :
1. Order : 139 0 83 279
2. Order : 414 288 84 0
3. Order : 302 547 598 766
4. Order : 54 419 1,190 483
5. Order : 0 0 108 1,356
6. Order : 30 0 18 0
7. Order : 213 0 0 38
8. Order : 134 93 7 0
9. Order : 7 137 15 14
10. Order : 0 32 92 0
11. Order : 2 0 52 67
12. Order : 15 0 3 12
13. Order : 13 0 1 34
14. Order : 1 10 0 0
15. Order : 0 25 1 2
16. Order : 1 9 3 0
MAN B&W 17.07
Page of
MAN Diesel
MAN B&W L60ME-C8 198 70 24-8.0
External Forces and Moments, L60ME-C8 Layout point L
1
- SFOC
a) st order moments are, as standard, balanced so as to obtain equal values for horizontal and vertical moments for
all cylinder numbers.
c) 5 and 6-cylinder engines can be ftted with 2nd order moment compensators on the aft and fore end, reducing the
2nd order external moment.
Table 17.07.01
No of cylinder : 5 6 7 8 9
Firing type : -4-3-2-5 -5-3-4-2-6 -7-2-5-4-3-6 -8-3-4-7-2-5-6
-9-2-5-7-3-6-
4-8
External forces [kN] :
. Order : Horizontal 0 0 0 0 0
. Order : Vertical 0 0 0 0 0
2. Order : Vertical 0 0 0 0 0
4. Order : Vertical 0 0 0 0 0
6. Order : Vertical 0 7 0 0 0
External moments [kNm] :
. Order : Horizontal a) 80 0 07 360 338
. Order : Vertical a) 80 0 07 360 338
2. Order : Vertical ,870 c) ,30 c) 378 0 557
4. Order : Vertical 9 7 20 82 297
6. Order : Vertical 0 0 0 9
Guide force H-moments in [kNm] :
x No. of cyl. ,043 759 569 42 255
2 x No. of cyl. 87 47 49 46 -
3 x No. of cyl. 32 - - - -
Guide force X-moments in [kNm] :
. Order : 28 0 76 256 240
2. Order : 297 207 60 0 88
3. Order : 266 48 526 675 404
4. Order : 49 375 ,066 433 ,570
5. Order : 0 0 94 ,78 ,353
6. Order : 25 0 5 0 427
7. Order : 8 0 0 33 54
8. Order : 5 80 6 0 9
9. Order : 6 4 3 0
0. Order : 0 27 77 0 7
. Order : 2 0 5 65 8
2. Order : 8 0 4 4 27
3. Order : 5 0 39 45
4. Order : 0 0 45
5. Order : 0 26 3 2
6. Order : 9 3 0 4
MAN B&W 17.07
Page of
MAN Diesel
MAN B&W S50ME-C8 198 70 26-1.0
External Forces and Moments, S50ME-C8 Layout point L
1
- SFOC
a) st order moments are, as standard, balanced so as to obtain equal values for horizontal and vertical moments for
all cylinder numbers.
Table 17.07.01
A
v
a
i
l
a
b
l
e

o
n

r
e
q
u
e
s
t
A
v
a
i
l
a
b
l
e

o
n

r
e
q
u
e
s
t
A
v
a
i
l
a
b
l
e

o
n

r
e
q
u
e
s
t
No of cylinder : 5 6 7 8 9
Firing type : -4-3-2-5 -5-3-4-2-6 -7-2-5-4-3-6
-8-3-4-7-2-
5-6
-6-7-3-5-8-
2-4-9
External forces [kN] :
. Order : Horizontal 0 0 0 0 0
. Order : Vertical 0 0 0 0 0
2. Order : Vertical 0 0 0 0 0
4. Order : Vertical 0 0 0 0 0
6. Order : Vertical 0 7 0 0 0
External moments [kNm] :
. Order : Horizontal a) 92 0 55 83 88
. Order : Vertical a) 92 0 55 83 88
2. Order : Vertical ,060 738 24 0 24
4. Order : Vertical 6 50 4 57 72
6. Order : Vertical 0 0 0 0 6
Guide force H-moments in [kNm] :
x No. of cyl. 302 85
2 x No. of cyl. 29 -
3 x No. of cyl. - -
Guide force X-moments in [kNm] :
. Order : 60 64
2. Order : 0 59
3. Order : 483 597
4. Order : 285 355
5. Order : 794 34
6. Order : 0 602
7. Order : 22 28
8. Order : 0 4
9. Order : 8 0
0. Order : 0 5
. Order : 38 3
2. Order : 7 28
3. Order : 9 7
4. Order : 0 9
5. Order : 2 26
6. Order : 0 2
MAN B&W
MAN Diesel
Appendix

A
MAN B&W Appendix A
Page 1 of 3
MAN Diesel
MAN B&W MC/MCC, ME/MEC/MEGI/ME-B engines 198 38 662.3
No. Symbol Symbol designation
1 General conventional symbols
1.1 Pipe
1.2 Pipe with indication of direction of ow
1.3 Valves, gate valves, cocks and aps
1.4 Appliances
1.5 Indicating and measuring instruments
2 Pipes and pipe joints
2.1 Crossing pipes, not connected
2.2 Crossing pipes, connected
2.3 Tee pipe
2.4 Flexible pipe
2.5 Expansion pipe (corrugated) general
2.6 Joint, screwed
2.7 Joint, anged
2.8 Joint, sleeve
2.9 Joint, quickreleasing
2.10 Expansion joint with gland
2.11 Expansion pipe
2.12 Cap nut
2.13 Blank ange
No. Symbol Symbol designation
2.14 Spectacle ange
2.15 Bulkhead tting water tight, ange
2.16 Bulkhead crossing, nonwatertight
2.17 Pipe going upwards
2.18 Pipe going downwards
2.19 Orice
3 Valves, gate valves, cocks and aps
3.1 Valve, straight through
3.2 Valves, angle
3.3 Valves, three way
3.4 Nonreturn valve (ap), straight
3.5 Nonreturn valve (ap), angle
3.6
Nonreturn valve (ap), straight, screw
down
3.7
Nonreturn valve (ap), angle, screw
down
3.8 Flap, straight through
3.9 Flap, angle
3.10 Reduction valve
3.11 Safety valve
3.12 Angle safety valve
3.13 Selfclosing valve
Symbols for Piping
MAN B&W Appendix A
Page 2 of 3
MAN Diesel
MAN B&W MC/MCC, ME/MEC/MEGI/ME-B engines 198 38 662.3
No. Symbol Symbol designation
3.14 Quickopening valve
3.15 Quickclosing valve
3.16 Regulating valve
3.17 Kingston valve
3.18 Ballvalve (cock)
3.19 Buttery valve
3.20 Gate valve
3.21 Doubleseated changeover valve
3.22 Suction valve chest
3.23
Suction valve chest with nonreturn
valves
3.24
Doubleseated changeover valve,
straight
3.25 Doubleseated changeover valve, angle
3.26 Cock, straight through
3.27 Cock, angle
3.28 Cock, threeway, Lport in plug
3.29 Cock, threeway, Tport in plug
3.30 Cock, fourway, straight through in plug
3.31 Cock with bottom connection
3.32
Cock, straight through, with bottom
conn.
3.33 Cock, angle, with bottom connection
3.34
Cock, threeway, with bottom connec-
tion
No. Symbol Symbol designation
4 Control and regulation parts
4.1 Handoperated
4.2 Remote control
4.3 Spring
4.4 Mass
4.5 Float
4.6 Piston
4.7 Membrane
4.8 Electric motor
4.9 Electromagnetic
5 Appliances
5.1 Mudbox
5.2 Filter or strainer
5.3 Magnetic lter
5.4 Separator
5.5 Steam trap
5.6 Centrifugal pump
5.7 Gear or screw pump
5.8 Hand pump (bucket)
5.9 Ejector
5.10 Various accessories (text to be added)
MAN B&W Appendix A
Page 3 of 3
MAN Diesel
MAN B&W MC/MCC, ME/MEC/MEGI/ME-B engines 198 38 662.3
Fig. A.01.01: Symbols for piping
The symbols used are in accordance with ISO/R 5381967, except symbol No. 2.19
178 30 614.1
No. Symbol Symbol designation
5.11 Piston pump
6 Fittings
6.1 Funnel
6.2 Bellmounted pipe end
6.3 Air pipe
6.4 Air pipe with net
6.5 Air pipe with cover
6.6 Air pipe with cover and net
6.7 Air pipe with pressure vacuum valve
6.8
Air pipe with pressure vacuum valve with
net
6.9 Deck ttings for sounding or lling pipe
6.10
Short sounding pipe with selfclosing
cock
6.11 Stop for sounding rod
No. Symbol Symbol designation
7
Indicating instruments with ordinary
symbol designations
7.1 Sight ow indicator
7.2 Observation glass
7.3 Level indicator
7.4 Distance level indicator
7.5 Counter (indicate function)
7.6 Recorder