Professional Documents
Culture Documents
Dynex PF 1300 Specs
Dynex PF 1300 Specs
82,55
82,50
( )
2.50
(63,5)
OUTLET PORT NO. 6 S.A.E.;
OR 3/8 MEDIUM PRESSURE CONED AND
THREADED, .5625-18 U.N.F.2B THREADED
(AUTOCLAVE, BUTECH M/P OR EQUIVALENT);
OR G 1/4 (B.S.P.)
.875
.873
22,23
22,17
( )
.990
.980
25,15
24,89
( )
SQUARE KEY
.25 x 1.0 (6,4 x 25)
5.00
(127,0)
3.95
(100,3)
INLET PORT
NO. 16 S.A.E.
7.59
(192,8)
CONED AND
THREADED PORT
7.69
(195,3)
S.A.E. OR
B.S.P. PORT
.25
(6,4)
.50
(12,7)
1.62
(41,1)
1.52
(38,6)
8.19
(208,0)
BLEED PORT FOR
VERTICAL MOUNTING
1/8-27 N.P.T.F.
2.63
(66,8)
B.S.P.,
S.A.E.
PORT
2.44
(61,9)
CONED AND
THREADED
PORT
INSTALLATION AND OPERATING
Refer to separate Bulletin PSI.CB for
general installation and operating
recommendations.
All dimensions are shown in inches
(millimeters in parentheses) and are
nominal.
Note that Models PF1301, PF1303, PF1305
and PF1308 have three pistons. Other
models have five pistons.
Mounting
S.A.E. A 2-bolt pattern with 0.25 inch
(6,4 mm) pilot engagement.
Shaft
Standard keyed shaft, 0.875 inch
(22,20 mm) diameter;
Optional spline shaft, 0.873/0.872 inch
diameter standard S.A.E. 13 tooth,
16/32 D.P. 30 involute spline.
Outlet Port Options
Standard pressure models are available
with S.A.E. ports. High pressure H
option models require the use of outlet
port option A (Autoclave Medium
Pressure, Butech M/P or equivalent
fittings), or outlet port option B (British
Standard Pipe fittings).
Hydraulic Fluid Viscosity Guidelines
Operating
Start-up Minimum Maximum
SUS cSt SUS cSt SUS cSt
31 1,3 927 200 927 200
If fluid conditions fall outside of the range shown, contact the sales department.
Inlet Conditions
Pumps using water-based fluids require
a flooded inlet up to 1800 rpm rated
speed. Higher viscosity fluids may require
pressurized inlet conditions.
Contact the sales department for
applications requiring continuous duty
operation at speeds higher or lower
than shown in the Typical Performance
Curves.
Orientation/Drive
Shaft horizontal with inlet vertically up
is preferred. Vertical shaft mounting is
possible, but requires connecting a line
to the bleed port to remove air from the
pump housing.
Seal Options
Standard seals are Buna-N (Nitrile) with
Polyurethane (Disogrin) o-rings in the
cover. Options include Fluorocarbon
(Viton or Fluorel) with Polyurethane
(Disogrin) o-rings in the cover, all
Fluorocarbon with high pressure shaft
seal, or EPR seals for use with some
phosphate ester fluids. Refer to Typical
Model Code.
Weight (Mass)
36 lb (16 kg)
FLUID RECOMMENDATIONS
For information on fluid recommendations
and minimum filtration levels, see page 5.
3
Typical performance curves are based on 33 SUS (1,9 cSt) water glycol fluid with flooded inlet. Contact the sales department
for applications requiring continuous duty operation at speeds higher or lower than shown.
Typical Performance Curves
Output Flow
(At 1800 rpm, at maximum pressure)
01
Standard: 0.31 (1,18 L/min)
H Option: 0.30 gpm (1,14 L/min)
03
Standard: 0.43 (1,63 L/min)
H Option: 0.42 gpm (1,58 L/min)
05
Standard: 0.55 (2,08 L/min)
H Option: 0.54 gpm (2,03 L/min)
08
Standard: 0.73 (2,76 L/min)
H Option: 0.72 gpm (2,73 L/min)
15
Standard: 0.91 (3,45 L/min)
H Option: 0.89 gpm (3,37 L/min)
18
Standard: 1.21 (4,58 L/min)
H Option: 1.20 gpm (4,54 L/min)
20 Standard: 1.42 (5,37 L/min)
Output flows based on typical performance
at maximum pressure. Refer to performance
curves for flows at lower pressure.
Models PF1301, PF1303, PF1305 and
PF1308 have three pistons. Other models
have five pistons.
PF13 01 H S D A 1 0
Operating Pressure
No Code Standard Pressure
H High Pressure
Requires A or B port option.
Pump Type
PF13
Fixed Displacement
Checkball Pump
Drive Shaft
No Code Keyed, .875 inch (22,23 mm) diameter
S S.A.E. Spline, .875 inch (22,23 mm) diameter
Ports
No Code Inlet No. 16 S.A.E.; Outlet No. 6 S.A.E.
A
Inlet No. 16 S.A.E.; Outlet 3/8 Medium
Pressure Coned and Threaded,
0.5625-18 U.N.F.-2B Threaded
Not recommended for operation above 8000 psi (560 bar).
Contact the fitting manufacturer for the pressure rating
of the fitting.
High pressure port uses Autoclave Medium Pressure,
Butech M/P or equivalent fitting.
Outlet port uses British Standard Pipe fitting. Not
recommended for operation above 10 000 psi (700 bar).
Design
Number
Modification
Number
TYPICAL MODEL CODE
Seals
D Standard: Buna-N (Nitrile) with Polyurethane (Disogrin
or Fluorel
) o-rings in
the cover and High Pressure Shaft Seal
XE All EPR with High Pressure Shaft Seal
or Fluorel
Operating
Start-up Optimum
Pump
Models
Minimum Maximum
SUS cSt SUS cSt SUS cSt SUS cSt
Fixed Displacement Pumps:
PF500-10 52 8 1911 413 3706 800 98 to 324 20 to 70
PF1000-10 59 10 1911 413 3706 800 98 to 324 20 to 70
PF2000 59 10 1911 413 1911 413 98 to 324 20 to 70
PF2000