Seamless and Welded Ferritic/Austenitic Stainless Steel Tubing for General Service 1 This standard is issued under the xed designation A 789/A 789M; the number immediately following the designation indicates the year of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A superscript epsilon (e) indicates an editorial change since the last revision or reapproval. 1. Scope * 1.1 This specication 2 covers grades of nominal wall thick- ness, stainless steel tubing for services requiring general corrosion resistance, with particular emphasis on resistance to stress corrosion cracking. These steels are susceptible to embrittlement if used for prolonged periods at elevated tem- peratures. NOTE 1For tubing smaller than 1 2 in. [12.7 mm] in outside diameter, the elongation values given for strip specimens in Table 1 shall apply. Mechanical property requirements do not apply to tubing smaller than 1 8 in. [3.2 mm] in outside diameter or with walls thinner than 0.015 in. [0.4 mm]. 1.2 The values stated in either inch-pound units or SI units are to be regarded separately as standard. Within the text, the SI units are shown in brackets. The values stated in each system are not exact equivalents; therefore, each system must be used independently of the other. Combining values from the two systems may result in nonconformance with the speci- cation. The inch-pound units shall apply unless the M desig- nation of this specication is specied in the order. 2. Referenced Documents 2.1 ASTM Standards: A 480/A 480M Specication for General Requirements for Flat-Rolled Stainless and Heat-Resisting Steel Plate, Sheet, and Strip 3 A 1016/A 1016M Specication for General Requirements for Ferritic Alloy Steel, Austenitic Alloy Steel, and Stain- less Steel Tubes 4 E 527 Practice for Numbering Metals and Alloys (UNS) 4 2.2 SAE Standard: 5 SAE J 1086 Practice for Numbering Metals and Alloys (UNS) 3. Ordering Information 3.1 Orders for product under this specication should in- clude the following, as required, to describe the desired material adequately: 3.1.1 Quantity (feet, metres, or number of lengths), 3.1.2 Name of product (seamless or welded tubes), 3.1.3 Grade (see Table 2), 3.1.4 Size (outside diameter and nominal wall thickness), 3.1.5 Length (specic or random), 3.1.6 Optional requirements (product analysis for welded tubes, Section 8; hydrostatic test or nondestructive electric test, Section 10), 3.1.7 Test report required (section on inspection of Speci- cation A 1016/A 1016M), 3.1.8 Specication designation, and 3.1.9 Special requirements. 1 This specication is under the jurisdiction of ASTM Committee A01 on Steel, Stainless Steel, and Related Alloys and is the direct responsibility of Subcommittee A01.10 on Stainless and Alloy Steel Tubular Products. Current edition approved Nov. 10, 2002. Published December 2002. Originally approved in 1981. Last previous edition approved in 2002 as A 789/A 789M 02. 2 For ASME Boiler and Pressure Vessel Code applications, see related Speci- cation SA789 in Section II of that Code. 3 Annual Book of ASTM Standards, Vol 01.03. 4 Annual Book of ASTM Standards, Vol 01.01. 5 Available from Society of Automotive Engineers (SAE), 400 Commonwealth Dr., Warrendale, PA 15096-0001. TABLE 1 Tensile and Hardness Requirements UNS Designation Tensile Strength, min, ksi [MPa] Yield Strength, min, ksi [MPa] Elongation in 2 in. or 50 mm, min, % Hardness, max Brinell HRC S31803 90 [620] 65 [450] 25 290 30 S32205 95 [655] 70 [485] 25 290 30 S31500 92 [630] 64 [440] 30 290 30 S32550 110 [760] 80 [550] 15 297 31 S31200 100 [690] 65 [450] 25 280 . . . S31260 A 100 [690] 65 [450] 25 290 30 S32001 90 [620] 65 [450] 25 290 30 S32304 OD 1 in. [25 mm] and Under 100 [690] 65 [450] 25 . . . . . . OD over 1 in. [25 mm] 87 [600] 58 [400] 25 290 30 S39274 116 [800] 80 [550] 15 310 . . . S32750 116 [800] 80 [550] 15 300 32 S32760 109 [750] 80 [550] 25 300 . . . S32900 90 [620] 70 [485] 20 271 28 S32950 B 100 [690] 70 [480] 20 290 30 S39277 120 [825] 90 [620] 25 290 30 S32520 112 [770] 80 [550] 25 310 . . . S32906 Wall below 0.40 in. (10 mm) 116 [800] 94 [650] 25 300 32 Wall 0.40 in. (10 mm) and above 109 [750] 80 [550] 25 300 32 S32003 90 [620] 65 [450] 25 290 30 A Prior to A 789/A 789M 87, the values for S31260 were: 92 ksi tensile strength, 54 ksi yield strength, and 30 % elongation. B Prior to A 789/A 789M 89, the tensile strength value was 90 ksi for UNS S32950. 1 *A Summary of Changes section appears at the end of this standard. Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States. NOTICE: This standard has either been superseded and replaced by a new version or withdrawn. Contact ASTM International (www.astm.org) for the latest information 4. General Requirements 4.1 product furnished under this specication shall conform to the applicable requirements of Specication A 1016/ A 1016M, unless otherwise provided herein. 5. Manufacture 5.1 The tubes shall be made by the seamless or welded process with no ller metal added. 6. Heat Treatment 6.1 All tubes shall be furnished in the heat-treated condition in accordance with the procedures shown in Table 3. For seamless tubes, as an alternate to nal heat treatment in a continuous furnace or batch-type furnace, immediately follow- ing hot forming while the temperature of the tubes is not less than the specied minimum solution treatment temperature, tubes may be individually quenched in water or rapidly cooled by other means. 7. Chemical Composition 7.1 The steel shall conform to the chemical requirements prescribed in Table 2. 8. Product Analysis 8.1 An analysis of either one billet or one length of at-rolled stock or one tube shall be made from each heat. The chemical composition thus determined shall conform to the requirements specied. 8.2 A product analysis tolerance of Table labeled A1.1 in Specication A 480/A 480M shall apply. The product analysis tolerance is not applicable to the carbon content for material with a specied maximum carbon of 0.04 % or less. 8.3 If the original test for product analysis fails, retests of two additional billets, lengths of at-rolled stock, or tubes shall be made. Both retests for the elements in question shall meet the requirements of this specication; otherwise, all remaining material in the heat shall be rejected or, at the option of the producer, each billet or tube may be individually tested for acceptance. Billets, lengths of at-rolled stock, or tubes that do not meet the requirements of this specication shall be re- jected. NOTE 2For ange and aring requirements, the term lot applies to all tubes prior to cutting of the same nominal size and wall thickness that are produced from the same heat of steel. When nal heat treatment is in a batch-type furnace, a lot shall include only those tubes of the same size and from the same heat that are heat treated in the same furnace charge. When the nal heat treatment is in a continuous furnace, or when heat TABLE 2 Chemical Requirements UNS Designation A C Mn P S Si Ni Cr Mo N Cu Others S31803 0.030 max 2.00 max 0.030 max 0.020 max 1.00 max 4.56.5 21.023.0 2.53.5 0.080.20 . . . . . . S32205 0.030 max 2.00 max 0.030 max 0.020 max 1.00 max 4.56.5 22.023.0 3.03.5 0.140.20 . . . . . . S31500 0.030 max 1.202.00 0.030 max 0.030 max 1.402.00 4.35.2 18.019.0 2.503.00 0.050.1 . . . . . . S32550 0.04 max 1.50 max 0.040 max 0.030 max 1.00 max 4.56.5 24.027.0 2.93.9 0.100.25 1.502.50 . . . S31200 0.030 max 2.00 max 0.045 max 0.030 max 1.00 max 5.56.5 24.026.0 1.202.00 0.140.20 . . . . . . S31260 0.030 max 1.00 max 0.030 max 0.030 max 0.75 max 5.57.5 24.026.0 2.53.5 0.100.30 0.200.80 W 0.100.50 S32001 0.030 max 4.006.00 0.040 max 0.030 max 1.00 max 1.03.0 19.521.5 0.60 max 0.050.17 1.00 max . . . S32304 0.030 max 2.50 max 0.040 max 0.040 max 1.00 max 3.05.5 21.524.5 0.050.60 0.050.20 0.050.60 . . . S39274 0.030 max 1.00 max 0.030 max 0.020 max 0.80 max 6.08.0 24.026.0 2.53.5 0.240.32 0.200.80 W 1.502.50 S32750 0.030 max 1.20 max 0.035 max 0.020 max 0.80 max 6.08.0 24.026.0 3.05.0 0.240.32 0.50 max . . . S32760 0.05 max 1.00 max 0.030 max 0.010 max 1.00 max 6.08.0 24.026.0 3.04.0 0.200.30 0.501.00 W 0.501.00 40 min B S32900 0.08 max 1.00 max 0.040 max 0.030 max 0.75 max 2.55.0 23.028.0 1.002.00 . . . . . . . . . S32950 0.030 max 2.00 max 0.035 max 0.010 max 0.60 max 3.55.2 26.029.0 1.002.50 0.150.35 . . . . . . S39277 0.025 max 0.80 max 0.025 max 0.002 max 0.80 max 6.58.0 24.026.0 3.004.00 0.230.33 1.202.00 W 0.801.21 S32520 0.030 max 1.50 max 0.035 max 0.020 max 0.80 max 5.58.0 23.025.0 3.5. 0.200.35 0.503.00 . . . S32906 0.030 max 1.50 max 0.80 min 0.030 max 0.030 max 0.50 max 7.5 max 5.8 min 30.0 max 28.0 min 2.60 max 1.50 min 0.40 .30 0.80 . . . . . . . . . S32003 0.030 max 2.00 max 0.030 max 0.020 max 1.00 max 3.0-4.0 19.5-22.5 1.50-2.00 0.14-0.20 . . . . . . A New designation established in accordance with Practice E 527 and SAE J1086. B % Cr + 3.3 3 % Mo + 163 % N. TABLE 3 Heat Treatment UNS Designation Temperature Quench S32003 18502050F [10101120C] rapid cooling in air or water S31803 18702010F [10201100C] rapid cooling in air or water S32205 18702010F [10201100C] rapid cooling in air or water S31500 18001900F [9801040C] rapid cooling in air or water S32550 1900F [1040C] min rapid cooling in air or water S31200 19202010F [10501100C] rapid cooling in water S31260 18702010F [10201100C] rapid cooling in water S32001 18001950F [9821066C] rapid cooling in air or water S32304 17001920F [9251050C] rapid cooling in air or water S39274 19202060F [10251125C] rapid cooling in air or water S32750 18802060F [10251125C] rapid cooling in air or water S32760 20102085F [11001140C] rapid cooling in air or water S32900 17001750F [925955C] rapid cooling in air or water S32950 18201880F [9901025C] air cool S39277 19752155F [10801180C] rapid cooling in air or water S32520 19752050F [10801120C] rapid cooling in air or water S32906 19001980F [10401080C] rapid cooling in air or water A 789/A 789M 02a 2 treated condition is obtained directly by quenching after hot forming, the number of tubes of the same size and from the same heat in a lot shall be determined from the size of the tubes as prescribed in Table 4. NOTE 3For tension and hardness test requirements, the term lot applies to all tubes prior to cutting, of the same nominal diameter and wall thickness that are produced from the same heat of steel. When nal heat treatment is in a batch-type furnace, a lot shall include only those tubes of the same size and the same heat that are heat treated in the same furnace charge. When the nal heat treatment is in a continuous furnace, or when heat treated condition is obtained directly by quenching after hot forming, a lot shall include all tubes of the same size and heat, heat treated in the same furnace at the same temperature, time at heat, and furnace speed, or all tubes of the same size and heat, hot formed and quenched in the same production run. 9. Mechanical Tests Required 9.1 Tension TestsOne tension test shall be made on a specimen for lots of not more than 50 tubes. Tension tests shall be made on specimens from two tubes for lots of more than 50 tubes (see Note 3). 9.2 Flaring Test (for Seamless Tubes)One test shall be made on specimens from one end of one tube from each lot (see Note 2) of nished tubes. The minimum expansion of the inside diameter shall be 10 %. 9.3 Flange Test (for Welded Tubes)One test shall be made on specimens from one end of one tube from each lot (see Note 2) of nished tubes. 9.4 Hardness TestBrinell or Rockwell hardness tests shall be made on specimens from two tubes from each lot (see Note 3). 9.5 When more than one heat is involved, the tension, aring, anging, and hardness test requirements shall apply to each heat. 9.6 Reverse Flattening TestFor welded tubes, one reverse attening test shall be made on a specimen from each 1500 ft [450 m] of nished tubing. 10. Hydrostatic or Nondestructive Electric Test 10.1 Each tube shall be subjected to the nondestructive electric test or the hydrostatic test. The type of test to be used shall be at the option of the manufacturer, unless otherwise specied in the purchase order. 10.2 The hydrostatic test shall be in accordance with Speci- cation A 1016/A 1016M, except that in the calculation of the hydrostatic test pressure 64000(441.2) shall be substituted for 32000(220.6). 11. Tensile and Hardness Properties 11.1 The material shall conform to the tensile and hardness properties prescribed in Table 1. 12. Permissible Variations in Dimensions 12.1 Variations in outside diameter, wall thickness, and length from those specied shall not exceed the amounts prescribed in Table 5. 12.2 The permissible variations in outside diameter given in Table 5 are not sufficient to provide for ovality in thin-walled tubes, as dened in the table. In such tubes, the maximum and minimum diameters at any cross section shall deviate from the nominal diameter by no more than twice the permissible variation in outside diameter given in Table 5; however, the mean diameter at that cross section must still be within the given permissible variation. 13. Surface Condition 13.1 All tubes shall be free of excessive mill scale, suitable for inspection. A slight amount of oxidation will not be considered as scale. Any special nish requirements shall be subject to agreement between the manufacturer and the pur- chaser. 14. Product Marking 14.1 In addition to the marking prescribed in Specication A 1016/A 1016M, the marking shall indicate whether the tubing is seamless or welded. 15. Keywords 15.1 duplex stainless steel; ferritic/austenitic stainless steel; seamless steel tube; stainless steel tube; steel tube; welded steel tube TABLE 4 Number of Tubes in a Lot Heat Treated by the Continuous Process or by Direct Quench after Hot Forming Size of Tube Size of Lot 2 in. [50.8 mm] and over in outside diameter and 0.200 in. [5.1 mm] and over in wall thickness not more than 50 tubes Less than 2 in. [50.8 mm] but over 1 in. [25.4 mm] in outside diameter or over 1 in. [25.4 mm] in outside diameter and under 0.200 in. [5.1 mm] in wall thickness not more than 75 tubes 1 in. [25.4 mm] or less in outside diameter not more than 125 tubes A 789/A 789M 02a 3 SUPPLEMENTARY REQUIREMENTS The following supplementary requirement shall apply only when specied by the purchaser in the inquiry, contract, or order. S1. Air-Underwater Pressure Test S1.1 When specied, each tube shall be examined by the air underwater pressure test. SUMMARY OF CHANGES This section identies the location of changes to this specication that have been incorporated since the last issue, A 789/A 789M-02: (1) Modied hardness values in Table 1: Tensile and Hardness Requirements. ASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentioned in this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the risk of infringement of such rights, are entirely their own responsibility. This standard is subject to revision at any time by the responsible technical committee and must be reviewed every ve years and if not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standards and should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of the responsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you should make your views known to the ASTM Committee on Standards, at the address shown below. This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the above address or at 610-832-9585 (phone), 610-832-9555 (fax), or service@astm.org (e-mail); or through the ASTM website (www.astm.org). TABLE 5 Permissible Variations in Dimensions Group Size, Outside Diameter, in. [mm] Permissible Variations in Outside Diameter, in. [mm] Permissible Variations in Wall Thickness, A % Permissible Variations in Cut Length, in. B [mm] Thin Walled Tubes C Over Under 1 Up to 1 2 [12.7], excl 60.005 [0.13] 615 1 8 [3] 0 . . . 2 1 2 to 1 1 2 [12.7 to 38.1], excl 60.005 [0.13] 610 1 8 [3] 0 less than 0.065 in. [1.6 mm] nominal 3 1 1 2 to 3 1 2 [38.1 to 88.9], excl 60.010 [0.25] 610 3 16 [5] 0 less than 0.095 in. [2.4 mm] nominal 4 3 1 2 to 5 1 2 [88.9 to 139.7], excl 60.015 [0.38] 610 3 16 [5] 0 less than 0.150 in. [3.8 mm] nominal 5 5 1 2 to 8 [139.7 to 203.2], incl 60.030 [0.76] 610 3 16 [5] 0 less than 0.150 in. [3.8 mm] nominal A When tubes as ordered require wall thicknesses 3 4 in. [19 mm] or over, or an inside diameter 60 % or less of the outside diameter, a wider variation in wall thickness is required. On such sizes a variation in wall thickness of 12.5 % over or under will be permitted. For tubes less than 1 2 in. [12.7 mm] in inside diameter that cannot be successfully drawn over a mandrel, the wall thickness may vary6 15 % from that specied. B These tolerances apply to cut lengths up to and including 24 ft [7.3 m]. For lengths greater than 24 ft [7.3 m], the above over-tolerances shall be increased by 1 8 in. [3 mm] for each 10 ft [3 m] or fraction thereof over 24 ft or 1 2 in. [13 mm], whichever is the lesser. C Ovality provisions of 12.2 apply. A 789/A 789M 02a 4