Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

520l0344 Folletos

Download as pdf or txt
Download as pdf or txt
You are on page 1of 80

MAKING MODERN LIVING POSSIBLE

Technical Information

Proportional Valve Group


PVG 32

powersolutions.danfoss.com

Technical Information

PVG 32 Proportional Valve Group

Revision History

Table of Revisions

Date

Changed

Rev

Feb 2014

Spec. sheet update

HE

Jan 2014

Converted to Danfoss layout DITA CMS

HD

Feb 2006 - Aug 2013

Various changes

BA - HC

Jan 2005

New Edition

AA

520L0344 Rev HE Feb 2014

Technical Information

PVG 32 Proportional Valve Group

Contents
General description

Safety in application

Function

PVG 32 technical data

Electrical actuation

Features of PVG 32........................................................................................................................................................................... 6


PVG modules .....................................................................................................................................................................................6
PVP, pump side modules..........................................................................................................................................................6
PVB, basic modules.....................................................................................................................................................................7
Actuation modules..................................................................................................................................................................... 7
Remote control units ......................................................................................................................................................................7
PVG 32 with open center PVP (fixed displ. pump) PVB with flow control spool.....................................................8
PVG 32 with closed center PVP (variable displ. pump) PVB with flow control spool............................................ 9
PVG 32 sectional drawing........................................................................................................................................................... 10
Load sensing for variable displ. pump supply.....................................................................................................................11
Control system example..............................................................................................................................................................12
Typical wiring block diagram example.............................................................................................................................14
PVG32 Mainly used in system with fixed displacement pumps...........................................................................16
PVG100 Alternative LS dump or pilot supply disconnect...................................................................................... 16
PVG120 Pump disconnect/block for variable pumps.............................................................................................. 16
Load sensing controls...................................................................................................................................................................17
LS control with bleed orifice (do not use with PVG valves).......................................................................................17
Integral PC function................................................................................................................................................................. 17
Load sensing system characteristics:.................................................................................................................................17
Remote pressure compensated controls.............................................................................................................................. 17
Remote pressure compensated system characteristics:............................................................................................ 18
Typical applications for remote pressure compensated systems:..........................................................................18
PVG 32 main spool with pressure compensated control................................................................................................ 18
Pressure compensated system characteristics.............................................................................................................. 19
Typical applications for pressure compensated systems...........................................................................................19
PVPC adapter for external pilot oil supply............................................................................................................................ 20
PVPC with check valve for open center PVP................................................................................................................... 20
PVPC without check valve for open or closed center PVP.........................................................................................21
PVMR, friction detent....................................................................................................................................................................23
PVMF, mechanical float position lock.....................................................................................................................................23
PVBS, main spools for flow control (standard).................................................................................................................... 23
PVBS, main spools for flow control (linear characteristic)............................................................................................... 23
PVBS, main spools for pressure control................................................................................................................................. 24
Background.................................................................................................................................................................................24
Principle....................................................................................................................................................................................... 25
Application..................................................................................................................................................................................25
Sizing.............................................................................................................................................................................................26
Limitation.................................................................................................................................................................................... 26
PVPX, electrical LS unloading valve.........................................................................................................................................26
PVH, hydraulic actuation............................................................................................................................................................. 28
PVM, mechanical actuation........................................................................................................................................................28
PVE technical data......................................................................................................................................................................... 28
PVPX, electrical LS unloading valve.........................................................................................................................................31
Electrical control of PVG.............................................................................................................................................................. 32
Closed loop control....................................................................................................................................................................... 33
PVEO................................................................................................................................................................................................... 34
PVEM...................................................................................................................................................................................................35
PVEA, PVEH, PVES, PVEU.............................................................................................................................................................. 35
PVEP.................................................................................................................................................................................................... 35
PVED-CC and PVED-CX.................................................................................................................................................................35

520L0344 Rev HE Feb 2014

Technical Information

PVG 32 Proportional Valve Group

Contents
PVHC................................................................................................................................................................................................... 36
Technical characteristics

Hydraulic systems

Other operating conditions

Dimensions

General...............................................................................................................................................................................................38
PVP, pump side module.............................................................................................................................................................. 38
Pressure relief valve characteristic in PVP........................................................................................................................38
PVB, basic modules oil flow characteristics.......................................................................................................................... 38
Pressure-compensated PVB, open or closed center PVP .......................................................................................... 39
PVB without pressure compensation, open center PVP.............................................................................................40
PVB without pressure compensation, closed center PVP.......................................................................................... 42
PVLP, shock and PVLA, suction valves...............................................................................................................................43
Pressure build-up for pressure controlled spools.........................................................................................................44
Pressure control spool flow characteristics.......................................................................................................................... 45
Examples of how to use the characteristics for pressure control spools...................................................................45
Characteristics for float position main spools..................................................................................................................... 46
Manually actuated PVG 32 fixed displ. pump.................................................................................................................. 48
Electrically actuated PVG 32 variable displ. pump......................................................................................................... 49
Oil.........................................................................................................................................................................................................50
Mineral oil....................................................................................................................................................................................50
Non-flammable fluids............................................................................................................................................................. 50
Particle content, degree of contamination...........................................................................................................................50
Biodegradable oils....................................................................................................................................................................50
Filtration............................................................................................................................................................................................ 50
System filters.............................................................................................................................................................................. 50
Internal filters............................................................................................................................................................................. 51
PVM, control lever positions...................................................................................................................................................... 55
Surface treatment.......................................................................................................................................................................... 55

Modules symbols, description and code numbers


PVP, pump side modules.............................................................................................................................................................56
PVB, basic modules........................................................................................................................................................................58
PVLP, shock and suction valve (fitted in PVB)...................................................................................................................... 59
PVLA, suction valve (fitted in PVB)........................................................................................................................................... 60
PVM, mechanical actuation........................................................................................................................................................60
PVH, hydraulic actuation............................................................................................................................................................. 61
PVS, end plate..................................................................................................................................................................................61
PVAS, assembly kit.........................................................................................................................................................................62
PVPX, electrical LS unloaded valve.......................................................................................................................................... 62
PVPC, plug for external pilot oil supply..................................................................................................................................62
Module selection chart

Order specification

Standard FC spools........................................................................................................................................................................64
Standard FC spools, hydraulic actuation...............................................................................................................................65
FC spools for mechanical float position, PVMF................................................................................................................... 65
FC spools for friction detent, PVMR.........................................................................................................................................65
FC spools with linear flow characteristic .............................................................................................................................. 66
Standard PC spools .......................................................................................................................................................................67
Standard PC spools, hydraulic actuation...............................................................................................................................68
PVB, basic valves.............................................................................................................................................................................69
PVP, pump side module.............................................................................................................................................................. 70
PVE, electrical actuation.............................................................................................................................................................. 72
Please state.......................................................................................................................................................................................74
Standard and option assembly................................................................................................................................................. 74

520L0344 Rev HE Feb 2014

Technical Information

PVG 32 Proportional Valve Group

Contents
Reordering........................................................................................................................................................................................74
Pressure setting limits.................................................................................................................................................................. 74
PVG 32 order specification form...............................................................................................................................................76

520L0344 Rev HE Feb 2014

Technical Information

PVG 32 Proportional Valve Group

General description

PVG 32 is a hydraulic load sensing valve designed to give maximum flexibility. From a simple load sensing
directional valve, to an advanced electrically controlled load-independent proportional valve.
The PVG 32 modular system makes it possible to build up a valve group to meet requirements precisely.
The compact external dimensions of the valve remain unchanged whatever combination is specified.
Features of PVG 32

Load-independent flow control:

Oil flow to an individual function is independent of the load pressure of this function
Oil flow to one function is independent of the load pressure of other functions

Good regulation characteristics


Energy-saving
Up to 12 basic modules per valve group
Several types of connection threads
Low weight
Compact design and installation

PVG modules
PVP, pump side modules

Built-in pressure relief valve


Pressure gauge connection
Versions:

Open center version for systems with fixed displacement pumps


Closed center version for systems with variable displacement pumps
Pilot oil supply for electrical actuator built into the pump side module
Pilot oil supply for hydraulic actuation built into the pump side module
Versions prepared for electrical LS unloading valve PVPX

520L0344 Rev HE Feb 2014

Technical Information

PVG 32 Proportional Valve Group

General description
PVB, basic modules

Interchangeable spools
Depending on requirements the basic module can be supplied with:

Integrated pressure compensator in channel P


Load holding check valve in channel P
Shock/suction valves for A and B ports
LS pressure limiting valves individually adjustable for ports A and B
Different interchangeable spool variants
All versions suitable for mechanical, hydraulic and electrical actuation

Actuation modules
The basic module is always fitted with mechanical actuator PVM and PVMD, which can be combined with
the following as required:

Electrical actuator (11 - 32 V ===):

PVES proportional, Super


PVEH proportional, High performance
PVEH-F proportional high performance, Float
PVEA proportional low hysteresis
PVEM proportional, Medium performance
PVEO ON/OFF
PVEU proportional, voltage control, 0-10 V
PVED-CC Digital CAN controlled J1939/ISOBUS
PVED-CX Digital CAN controlled CANopen X-tra safety
PVEP PWM voltage controlled (11-32 V)
PVHC High Current actuator for PVG

PVMF, cover for Mechanical Float

Electrical remote control units:

PVMR, cover for Mechanical detent


PVH, cover for Hydraulic actuation

Remote control units

PVRE, PVRET
PVREL
PVRES
Prof 1
Prof 1 CIP
JS120

JS1000 Ball grip


JS1000 PRO grip
JS2000
JS6000
JS7000

Hydraulic remote control unit: PVRHH

520L0344 Rev HE Feb 2014

Technical Information

PVG 32 Proportional Valve Group

General description
Electrical and hydraulic remote control units
PVRE, electrical control unit, 162F

PVRH, hydraulic control unit, 155N

155N0003

PVREL, electrical control unit, 155U

155N0001

155N0004 155N0005 155N0002

PVRES, electrical control unit, 155B

Prof 1, 162F

PVG 32 with open center PVP (fixed displ. pump) PVB with flow control spool
When the pump is started and the main spools in the individual basic modules (11) are in the neutral
position, oil flows from the pump, through connection P, across the pressure adjustment spool (6) to
tank. The oil flow led across the pressure adjustment spool determines the pump pressure (stand-by
pressure).
When one or more of the main spools are actuated, the highest load pressure is fed through the shuttle
valve circuit (10) to the spring chamber behind the pressure adjustment spool (6), and completely or
partially closes the connection to tank to maintain pump pressure.
Pump pressure is applied to the right-hand side of the pressure adjustment spool (6).
The pressure relief valve (1) will open should the load pressure exceed the set value, diverting pump flow
back to tank.
In a pressure-compensated basic module the compensator (14) maintains a constant pressure drop
across the main spool both when the load changes and when a module with a higher load pressure is
actuated.
With a non pressure-compensated basic module incorporating a load drop check valve (18) in channel P,
the check valve prevents return oil flow.
The basic module can be supplied without the load drop check valve in channel P for functions with overcenter valves.
The shock valves PVLP (13) with fixed setting and the suction valves PVLA (17) on ports A and B are used
for the protection of the individual working function against overload and/or cavitation.
An adjustable LS pressure limiting valve (12) can be built into the A and B ports of pressure-compensated
basic modules to limit the pressure from the individual working functions.

520L0344 Rev HE Feb 2014

Technical Information

PVG 32 Proportional Valve Group

General description
Please see the sectional drawing below for better understanding of this example.
The LS pressure limiting valves save energy compared with the shock valves PVLP:

with PVLP all the oil flow to the working function will be led across the combined shock and suction
valves to tank if the pressure exceeds the fixed setting.
with LS pressure limiting valves an oil flow of about 2 l/min [0.5 US gal/min] will be led across the LS
pressure limiting valve to tank if the pressure exceeds the valve setting.

PVG 32 with closed center PVP (variable displ. pump) PVB with flow control spool
In the closed center version of PVP an orifice (5) and a plug (7) have been fitted instead of the plug (4).
This means that the pressure adjustment spool (6) will only open to tank when the pressure in channel P
exceeds the set value of the pressure relief valve (1).
In load sensing systems the load pressure is led to the pump control via the LS connection (8).
In the neutral position the pump load sense control sets the displacement so that leakage in the system is
compensated, to maintain the set stand-by pressure.
When a main spool is actuated the pump load sense control will adjust the displacement so that the set
differential pressure (margin) between P and LS is maintained.
The pressure relief valve (1) in PVP should be set at a pressure of approx. 30 bar [435 psi] above maximum
system pressure (set on the pump or external pressure relief valve).

520L0344 Rev HE Feb 2014

Technical Information

PVG 32 Proportional Valve Group

General description
PVG 32 sectional drawing
1

4+5
A

LS
8
9
12 7

13

11
10

14

16

LS B

P LS A
17 15
A

19

18

20
V310106.A

10

1 Pressure relief valve

11 Main spool

2 Pressure reduction valve for pilot oil supply

12 LS pressure limiting valve

3 Pressure gauge connection

13 Shock and suction valve, PVLP

4 Plug, open center

14 Pressure compensator

5 Orifice, closed center

15 LS connection, port A

6 Pressure adjustment spool

16 LS connection, port B

7 Plug, closed center

17 Suction valve, PVLA

8 LS connection

18 Load drop check valve

9 LS signal

19 Pilot oil supply for PVE

10 Shuttle valve

20 Max. oil flow adjustment screws for A/B ports

520L0344 Rev HE Feb 2014

Technical Information

PVG 32 Proportional Valve Group

General description
Load sensing for variable displ. pump supply
The pump receives fluid directly from the reservoir through the inlet line. A screen in the inlet line
protects the pump from large contaminants.
The pump outlet feeds directional control valves such as PVG-32, hydraulic integrated circuits (HIC), and
other types of control valves.
The PVG valve directs and controls pump flow to cylinders, motors and other work functions. A heat
exchanger cools the fluid returning from the valve. A filter cleans the fluid before it returns to the
reservoir.
Flow in the circuit determines the speed of the actuators. The position of the PVG valve spool determines
the flow demand. A hydraulic pressure signal (LS signal) communicates demand to the pump control.
The pump control monitors the pressure differential between pump outlet and the LS signal, and
regulates servo pressure to control the swashplate angle. Swashplate angle determines pump flow.
Actuator load determines system pressure. The pump control monitors system pressure and will decrease
the swashplate angle to reduce flow if system pressure reaches the pump control setting.
A secondary system relief valve in the PVG valve acts as a back-up to control system pressure.
Pictorial circuit diagram
K/LFrame Series 45
open circuit axial
piston pump with
load sensing contro l

Double-ac ting cylinder

PVG 32
multi-sec tion
load
sensing
contro l
valve

Bi-directional
gear moto r

System pressur e
Servo pressur e
Heat exchanger
Reservoir

Filter

Actuator pressur e
Load sense pressur e
Actuator retur n

P101 658E

520L0344 Rev HE Feb 2014

Suction / case drain /


system retur n

11

Technical Information

PVG 32 Proportional Valve Group

Safety in application

All makes and all types of control valves (incl. proportional valves) can fail, thus the necessary protection
against the serious consequences of function failure should always be built into the system. For each
application an assessment should be made for the consequences of pressure failure and uncontrolled or
blocked movements.
To determine the degree of protection that is required to be built into the application, system tools such
an FMEA (Failure Mode and Effect Analysis) and Hazard and Risk Analysis can be used.
FMEA IEC EN 61508
FMEA (Failure Mode and Effect Analysis) is a tool used for analyzing potential risks. This analytical
technique is utilized to define, identify, and prioritize the elimination or reduction of known and/or
potential failures from a given system before it is released for production. Please refer to IEC FMEA
Standard 61508.
Hazard and Risk Analysis ISO 12100-1 / 14121
This analysis is a tool used in new applications as it will indicate whether there are special safety
considerations to be met according to the machine directives EN 13849. Dependent on the determined
levels conformity this analysis will detirmine if any extra requirements for the product design,
development process, production process or maintenance, i.e. the complete product life cycle.

W Warning
All makes/brands and types of directional control valves inclusive proportional valves can fail and
cause serious damage. It is therefore important to analyze all aspects of the application.
Because the proportional valves are used in many different operation conditions and applications,
the manufacturer of the application is alone responsible for making the final selection of the products
and assuring that all performance, safety and warning requirements of the application are met.
The process of choosing the control system and safety levels is governed by the machine directives
EN 13849 (Safety related requirements for control systems).
Control system example
Example of a control system for manlift using PVE Fault monitoring input signals and signals from
external sensors to ensure the PLUS+1 main controllers correct function of the manlift.

12

520L0344 Rev HE Feb 2014

Technical Information

PVG 32 Proportional Valve Group

Safety in application
Control system example

Legend:
1 Main power supply
2 Emergency stop/man present switch
3 HMI/Joystick control
4 Movement detection sensors
5 Main controller
6 PVG control valve
7 Hydraulic deactivation

520L0344 Rev HE Feb 2014

13

Technical Information

PVG 32 Proportional Valve Group

Safety in application
Electrical block diagram for above illustration

Main power supply


(battery)

Emergency stop and


Man present switch

HMI / Joystick
Joystick
neutral switch
Control
Signal

Motion detection sensor


Main control valve

Supply

Main controller
Neutral Supply
Detection Control

Signal
Conditioning

Signal
Conditioning

Fault
Monitoring
PVE fault output

Failure
Detection

PVE

Hydraulic deactivation
P301 317

Warning
It is the responsibility of the equipment manufacturer that the control system incorporated in the
machine is declared as being in conformity with the relevant machine directives.

Typical wiring block diagram example


Example of a typical wiring block diagram using PVEH with neutral power off switch and fault monitoring
output for hydraulic deactivation.

14

520L0344 Rev HE Feb 2014

Technical Information

PVG 32 Proportional Valve Group

Safety in application
Typical wiring block diagram example
A

Emergency
stop

PVE 1
C

Man present
switch

Neutral detection / Supply control

PVEH

with AMP
connector
US
UDC2

1)
signal

neutral

OFF
Delay

PVE 2
C

PVEH

Neutral detection / Supply control

with AMP
connector
US
UDC2

1)
signal

neutral

Error

OFF
Delay

E1

Error

E2

2) Alarm
logic
Output
OR

3) Memory

AND

high=on
low=off

Fault detection output

Hydraulic
deactivation
P301 318

A Emergency stop / man present switch


B PVE Faultmonitoring signals
C Neutral signal detection.
D Hydraulic deactivation
System Control Logic e.g. PLUS+1 for signal monitoring and triggering signal for deactivation of the
hydraulic system.

Warning

It is the responsebilty of the equipment manufacturer that the control system incorporated in the
machine is declared as being in confirmity with the relevant machine directives.

520L0344 Rev HE Feb 2014

15

Technical Information

PVG 32 Proportional Valve Group

Safety in application
PVG32 Mainly used in system with fixed displacement pumps

PVSK, commonly used in crane application - full flow dump


PVPX, LS dump to tank

PVG100 Alternative LS dump or pilot supply disconnect

PVPP, pilot oil supply shut off


External cartridge valve connecting LS Pressure to Tank
External cartridge valve connecting main Pressure to Tank

PVG120 Pump disconnect/block for variable pumps

16

PVPE, full flow dump for the PVG 120


External cartridge valve connecting LS Pressure to Tank

520L0344 Rev HE Feb 2014

Technical Information

PVG 32 Proportional Valve Group

Function
Load sensing controls
The LS control matches system requirements for both pressure and flow in the circuit regardless of the
working pressure. Used with a closed center control valve, the pump remains in low-pressure standby
mode with zero flow until the valve is opened. The LS setting determines standby pressure.
Typical operating curve

Load sensing circuit

PC setting

Flow

Q max

Pressure

P101 968E

P101 967

Most load sensing systems use parallel, closed center, control valves with special porting that allows the
highest work function pressure (LS signal) to feed back to the LS control.
Margin pressure is the difference between system pressure and the LS signal pressure. The LS control
monitors margin pressure to read system demand. A drop in margin pressure means the system needs
more flow. A rise in margin pressure tells the LS control to decrease flow.
LS control with bleed orifice (do not use with PVG valves)
The load sense signal line requires a bleed orifice to prevent high-pressure lockup of the pump control.
Most load-sensing control valves include this orifice. An optional internal bleed orifice is available, for use
with control valves that do not internally bleed the LS signal to tank.
Integral PC function
The LS control also performs as a PC control, decreasing pump flow when system pressure reaches the PC
setting. The pressure compensating function has priority over the load sensing function.
For additional system protection, install a relief valve in the pump outlet line.
Load sensing system characteristics:

Variable pressure and flow


Low pressure standby mode when flow is not needed
System flow adjusted to meet system requirements
Lower torque requirements during engine start-up
Single pump can supply flow and regulate pressure for multiple circuits
Quick response to system flow and pressure requirements

Remote pressure compensated controls


The remote PC control is a two-stage control that allows multiple PC settings. Remote PC controls are
commonly used in applications requiring low and high pressure PC operation.

520L0344 Rev HE Feb 2014

17

Technical Information

PVG 32 Proportional Valve Group

Function

Typical operating curve

Closed center circuit with remote PC

PC setting

Remote PC setting

Flow

Q max

Pressur e

P101 969E

P101 966

The remote PC control uses a pilot line connected to an external hydraulic valve. The external valve
changes pressure in the pilot line, causing the PC control to operate at a lower pressure. When the pilot
line is vented to reservoir, the pump maintains pressure at the load sense setting.
When pilot flow is blocked, the pump maintains pressure at the PC setting. An on-off solenoid valve can
be used in the pilot line to create a low-pressure standby mode. A proportional solenoid valve, coupled
with a microprocessor control, can produce an infinite range of operating pressures between the low
pressure standby setting and the PC setting.
Size the external valve and plumbing for a pilot flow of 3.8l/min [1US gal/min]. For additional system
protection, install a relief valve in the pump outlet line.
Remote pressure compensated system characteristics:

Constant pressure and variable flow


High or low pressure standby mode when flow is not needed
System flow adjusts to meet system requirements
Single pump can provide flow to multiple work functions
Quick response to system flow and pressure requirements

Typical applications for remote pressure compensated systems:

Modulating fan drives


Anti-stall control with engine speed feedback
Front wheel assist
Road rollers
Combine harvesters
Wood chippers

PVG 32 main spool with pressure compensated control


The PC control maintains constant system pressure in the hydraulic circuit by varying the output flow of
the pump. Used with a closed center control valve, the pump remains in high pressure standby mode at
the PC setting with zero flow until the function is actuated.

18

520L0344 Rev HE Feb 2014

Technical Information

PVG 32 Proportional Valve Group

Function

Typical operating curve

Simple closed center circuit

PC setting

Flow

Q max

0
0

Pressur e

P101 166E

P101 965

Once the closed center valve is opened, the PC control senses the immediate drop in system pressure
and increases pump flow by increasing the swashplate angle.
The pump continues to increase flow until system pressure reaches the PC setting.
If system pressure exceeds the PC setting, the PC control reduces the swashplate angle to maintain
system pressure by reducing flow. The PC control continues to monitor system pressure and changes
swashplate angle to match the output flow with the work function pressure requirements.
If the demand for flow exceeds the capacity of the pump, the PC control directs the pump to maximum
displacement. In this condition, actual system pressure depends on the actuator load.
For additional system protection, install a relief valve in the pump outlet line.

C Caution
Do not use the PVG 32 with LB control.
Pressure compensated system characteristics

Constant pressure and variable flow


High pressure standby mode when flow is not needed
System flow adjusts to meet system requirements
Single pump can provide flow to multiple work functions
Quick response to system flow and pressure requirements

Typical applications for pressure compensated systems

Constant force cylinders (bailers, compactors, refuse trucks)


On/off fan drives
Drill rigs
Sweepers
Trenchers

520L0344 Rev HE Feb 2014

19

Technical Information

PVG 32 Proportional Valve Group

Function
PVPC adapter for external pilot oil supply
PVPC with check valve for open center PVP
PVPC with check valve is used in systems where it is necessary to operate the PVG 32 valve by means of
the electrical remote control without pump flow. When the external solenoid valve is opened, oil from
the pressure side of the cylinder is fed via the PVPC through the pressure reducing valve to act as the
pilot supply for the electrical actuators. This means that a load can be lowered by means of the remote
control lever without starting the pump.
The built-in check valve prevents the oil from flowing via the pressure adjustment spool to tank. With the
pump functioning normally the external solenoid valve is closed to ensure that the load is not lowered
due to the pilot supply oil flow requirement of approximately 1 l/min [0.25 US gal/min]. With closed
center PVP the external pilot oil supply can be connected to the pressure gauge connection without the
use of a PVPC plug.
PVPC with check valve for OC PVP

20

520L0344 Rev HE Feb 2014

Technical Information

PVG 32 Proportional Valve Group

Function
Hydraulic diagram

PVPC without check valve for open or closed center PVP


PVPC without check valve is used in systems where it is necessary to supply the PVG 32 valve with oil
from a manually operated emergency pump without directing oil flow to the pilot oil supply (oil
consumption about 0.5 l/min) [0.13 US gal/min].
When the main pump is working normally, the oil is directed through the PVPC plug via the pressure
reduction valve to the electrical actuators.

520L0344 Rev HE Feb 2014

21

Technical Information

PVG 32 Proportional Valve Group

Function
PVPC without check valve OC/CC PVP

Hydraulic diagram

22

520L0344 Rev HE Feb 2014

Technical Information

PVG 32 Proportional Valve Group

Function
When the main pump flow fails, the external shuttle valve ensures that the oil flow from the manually
operated emergency pump is used to pilot open the over center valve and lower the load. The load can
only be lowered using the mechanical operating lever of the PVG 32 valve.
PVMR, friction detent
The friction detent PVMR allows the directional
spool to be held in any position, resulting in
infinitely variable, reversible, pressure
compensated flow.

PVMR, friction detent

This can be sustained indefinitely without having


to continue to hold the mechanical lever.
Friction detent spool position may be affected by
high differential actuator flow forces and system
vibration resulting in work function flow reduction.

PVMF, mechanical float position lock


Allows the float spool to be held in the float position after release of the mechanical handle.
PVMF, standard mount only

PVMF, optional mount only

P A F (Push-in)

P A F (Pull-out)

PVBS, main spools for flow control (standard)


When using standard flow control spools, the pump pressure is determined by the highest load pressure.
This is done either via the pressure adjustment spool in open center PVP (fixed displacement pumps) or
via the pump control (variable displacement pumps).
In this way the pump pressure will always correspond to the load pressure plus the stand-by pressure of
the pressure adjustment spool or the pump control. This will normally give optimum and stable
adjustment of the oil flow.
PVBS, main spools for flow control (linear characteristic)
PVBS main spools with linear characteristic have less dead band than standard spools and a proportional
ratio between control signal and oil flow in the range beyond the dead band. PVBS with linear
characteristic must never be used together with PVEM electrical actuators.

520L0344 Rev HE Feb 2014

23

Technical Information

PVG 32 Proportional Valve Group

Function
The interaction between the small dead band of the spools and the hysteresis of the PVEM actuator of
20% involves a risk of building up a LS pressure in neutral position.
In a few systems load sensing pump pressure may result in unstable adjustment of the oil flow and a
tendency towards system hunting.
This may be the case with working functions that have a large moment of inertia or over-center valves. In
such systems main spools for pressure control can be advantageous.
PVBS, main spools for pressure control
The spools are designed in such a way that the pump pressure is controlled by the spool travel. The main
spool must be displaced until the pump pressure just exceeds the load pressure before the working
function is applied. If the main spool is held in this position, the pump pressure will remain constant
even if the load pressure changes giving a stable system.
The use of pressure control spools, however, also means that:

the oil flow is load dependent


the dead band is load dependent
the pump pressure can exceed the load pressure by more than is usual
the pressure drop across main spool varies (energy consumption)

Due to these factors it is recommended that pressure control spools are only used when it is known for
certain that problems with stability will arise or already have arisen, and in applications where constant
pressure is needed e.g. drill holding.
Background
Instability in load sense control systems in certain applications with oscillations in the range of 1/2 - 2 Hz
can cause severe instability problems while trying to control functions in an application.
Critical applications are usually related to functions with an important inertia torque and/or functions
with secondarily fitted pressure controlled components e.g. over-center valves.
Examples:

a slewing function
main lifting/lowering function of a crane

The problem usually manifests itself in prolonged oscillation phenomena (Fig. 1), in a relatively constant
sequence of oscillations (Fig. 2) or in the worst case in an amplified sequence of oscillations (Fig. 3).
Fig. 1 Prolonged sequence
P

Fig. 2 Constant sequence

Prolonged sequence

time

Fig. 3 Amplified sequence

Constant sequence

time

Amplified sequence

time

P005 627E

To control the oscillation phenomena the "pressure control spool" was developed and is a patented
system which can minimize most of the oscillation issues.

24

520L0344 Rev HE Feb 2014

Technical Information

PVG 32 Proportional Valve Group

Function
Principle
The idea was to create a system operating independently of a constantly changing load pressure.
Therefore, we changed the well-known LS principle (Fig. 4), so that compensated pump pressure is part
of the LS system (Fig. 5) after the pressure compensator and before the metering range of the main spool.
Upon actuation of the spool, it will be led via a fixed and a variable orifice.
Fig. 4 Flow controlled spool

Fig. 5 Pressure controlled spool

P005 625

The opening area of the variable orifice is at


maximum at initial actuation and 0 at full stroke of
the spool and then the pressure created between
the two orifices is led into the LS system in the
usual way.

P005 626

Pump pressure vs. spool travel curve

In this way the pump pressure is built up


depending on the spool travel, i.e. the spool will
then have to be stroked to a position that the
pump pressure is higher than the actual load
pressure to make the oil flow from PA/B. When
the load changes for a fixed spool position the flow
to for the function will also change.
The valve section is now a load-dependent valve,
but ensuring a constant pump pressure which is
important in obtaining a stable function.

Application
Pressure controlled spools should in principle only be used when you have stability issues. Typical
applications on a crane:

Lifting/lowering movement
Slewing movement with cylinders
For the main lifting/lowering function on a crane it is recommended to fit a "half" pressure control
spool. This means that the spool is designed with a normal flow control on the lifting port and
pressure control connected to the port where the pilot signal to the over-center valve is acting. You
will thus maintain a load-independent lifting movement and achieve a stable but load-depending
lowering movement.
As the load pressure on slewing movements is usually steady - irrespective of the crane being loaded
or not it will be advantageous to use a "full" pressure control spool for A and B port.

In both cases we recommend the use of a basic valve, PVB, with pressure compensator. The pressure
compensator will ensure the individual load-independency between the basic valves.
It is further recommended to use the LS pressure relief valves as not only will they ensure individual
pressure limitation but also make it possible to adjust the maximum oil flow to the function.

520L0344 Rev HE Feb 2014

25

Technical Information

PVG 32 Proportional Valve Group

Function
It is not recommended to use shock valves as pressure limiting valves in connection with pressure control
spools.
Sizing
The size of "half" (e.g: P - A = flow control P - B pressure control) pressure control spools is determined on
basis of max. flow demand on the lifting port. If e.g. a max. pressure compensated flow of 65 l/min for the
lifting movement, you choose a 65 L/min spool (size D). The metering characteristic has then a given size.
As it is often requested to limit the use of the crane boom for downward push/force mode and the LS
pressure limitation can be used. It will appear from the characteristics enclosed what effect a pressure
limitation, PLS will have on max. flow on the lowering port.
The size for a "full" pressure control spool is determined on basis of known load pressure, PLS max, and
requested max. flow.
It will appear from the characteristics enclosed that if the load PLS is low and the pump pressure, Pp, is
high as a result of max. stroked spool you will get a large flow.
If PLS is approaching PLS max. the flow will be reduced and the dead band increased. Max. oil flow can be
reduced by approx. 50% without limiting max. pressure.
The reduction is made by limiting the spool travel from 7 mm to 5.5 mm.
Limitation
If a pressure controlled spool is chosen for stability reasons consideration should be made to features
related to the pressure control principle.
Deadband will change according to the load conditions and the valve section will become loaddependent and that the pump pressure may exceed the load pressure.
With all of the above in mind, a pressure controlled spool will minimize oscillation and obtain a stable
function that can be controlled smooth and precise.
PVPX, electrical LS unloading valve
PVPX is a solenoid LS unloading valve. PVPX is fitted into the pump side module enabling a connection to
be made between the LS and the tank lines. Thus the LS signal can be relieved to tank by means of an
electric signal.
For a PVP pump side module in open center version the relief to tank of the LS signal means that the
pressure in the system is reduced to the sum of the tank port pressure plus the neutral flow pressure for
the pump side module.
For a PVP pump side module in closed center version the relief to tank of the LS signal means that the
pressure is reduced to the sum of the tank port pressure for the pump side module plus the stand-by
pressure of the pump.
PVPX, electrical LS unloading valve

26

520L0344 Rev HE Feb 2014

Technical Information

PVG 32 Proportional Valve Group

PVG 32 technical data

The characteristics in this catalog are typical measured values. During measuring a mineral based
hydraulic oil with a viscosity of 21 mm2/s [102 SUS] at a temperature of 50 C [122 F] was used.
PVG 32 technical data
Max. pressure

Oil flow rated

Port P continuous1)

350 bar

[5075 psi]

Port P intermittent 5)

400 bar

[5800 psi]

Port A/B continous

350 bar

[5075 psi]

Port A/B intermittent 5)

420 bar

[6090 psi]

Port T, static/dynamic

25/40 bar

[365/580 psi]

Port P3) 4)

140/230 l/min

[37/61 US gal/min]

Port A/B, with press. comp.2)

100 l/min

[26.4 US gal/min]

Port A/B witout press. comp.

125 l/min

[33 US gal/min]

7 mm

[ 0.28 in]

Spool travel, standard


Spool travel, float position

Proportional range

4.8 mm

0.19 in]

Float position

8 mm

[ 0.32 in]

Standard

1.5 mm

[ 0.06 in]

Linear characteristic

0.8 mm

[ 0.03 in]

Max. internal leakage


at 100 bar [1450 psi] and 21 mm2/s [102 SUS]

A/B T without shock valve

20 cm3/min

[1.85 in3/min]

A/B T with shock valve

25 cm3/min

[2.15 in3/min]

Oil temperature
(inlet temperature)

Recommended temperature

30 60 C

[86 140F]

Min. temperature

-30 C

[-22 F]

Dead band, flow control spools

+90 C

[194 F]

Ambient temperature

Max. temperature

-30 60 C

[-22 140 F]

Oil viscosity

Operating range

12 - 75 mm2/s

[65 - 347 SUS]

Min. viscosity

4 mm2/s

[39 SUS]

Max. viscosity

460 mm2/s

[2128 SUS]

Max. contamination
(ISO 4406)

23/19/16

23/19/16

5 l/min

[0.13 US gal/min]

Filtration
(See chapter Filtration)
Oil consumtion in pilot oil pressure reduction valve

1) With PVSI end plate. With PVS end plate max. 300 bar [4351 psi].
2) For 130 l/min contact Danfoss Product Application Engineering.
3) In open circuit systems with short P-hoses/tubes, attention should be paid to pressure peaks at flows
>100 l/min [26.4 US gal/min] .
4) For system with mid inlet PVPVM.
5) Intermittent pressure at max. 250,000 cycles of full PVG life time cycles, with PVSI end plate. The
maximum intermittent pressure at max. 250,000 cycles stresses the need to confirm application duty
cycle before proceeding with specification. For further information contact Danfoss Product Application
Engineering.
Rated Pressure
Product

Maximum continuous P-port pressure

PVG 32 with PVS

300 bar [4351 psi]

PVG 32 with PVSI

350 bar [5076 psi]

520L0344 Rev HE Feb 2014

27

Technical Information

PVG 32 Proportional Valve Group

PVG 32 technical data

Rated Pressure (continued)


Product

Maximum continuous P-port pressure

PVG 32 with PVBZ

250 bar [3626 psi]

PVG 32 with HIC steel

350 bar [5076 psi]

PVG 32 with HIC aluminium

210 bar [3046 psi]

PVG 120/32 with PVS

300 bar [4351 psi]

PVG 120/32 with PVSI

350 bar [5076 psi]

PVG 100/32 with PVS

300 bar [4351 psi]

PVG 100/32 with PVSI

350 bar [5076 psi]

PVH, hydraulic actuation


Technical data for PVH
Control range pressure

5 15 bar [75 220 psi]

Max. pilot pressure

30 bar [435 psi]

Max. pressure on port T


(The hydraulic remote control lever should be connected directly to
tank.)

10 bar [145 psi]

PVM, mechanical actuation


Technical data for PVM
Spool displacement

Operating Torque Nm [lbfin]


PVM + PVMD

PVM + PVE

PVM + PVH

PVM + PVMR

PVM+PVMF

from neutral position

2.2 0.2
[19.5 1.8]

2.2 0.2
[19.5 1.8]

2.5 0.2
[22.1 1.8]

17
[3.8]

22
[5.0]

max. spool travel

2.8 0.2
[24.8 1.8]

2.8 0.2
[24.8 1.8]

6.9 0.2
[61.0 1.8]

into float position

60 [13.5]

away from float position

28 [6.3]

from any other position

8.5 [73.3]

Control lever position

No

2x6

Control range

control lever

19.5

proportional

13.4

float position

22.3

For PVE please see the PVE, Series 4 for PVG 32/100/120 Technical Information, 520L0553.
PVE technical data
Technical data for PVEO and PVEM
Supply voltage UDC

Current consumption at rated voltage

28

520L0344 Rev HE Feb 2014

rated

12 VDC

24 VDC

range

11 V to 15 V

22 V to 30 V

max. ripple

5%
0.65 A @ 12 V

0.33 A @ 24 V

Technical Information

PVG 32 Proportional Valve Group

PVG 32 technical data

Technical data for PVEO and PVEM (continued)


Signal voltage (PVEM)

neutral

0.5 x UDC

A-port B-port

0.25 UDC to 0.75 UDC

Signal current at rated voltage (PVEM)

0.25 mA

Input impedance in relation to 0.5 UDC

12 K

Power consumption

8W

0.50 mA

Reaction time for PVEO and PVEM


Supply voltage

Function

Disconnected by means of
neutral switch

Reaction time from neutral


position to max. spool travel

Disconnected by means
of neutral switch

Constant voltage

Reaction time from max.


spool travel to neutral
position
Reaction time from neutral
position to max. spool
position

Constant voltage

Reaction time from max.


spool travel to neutral
position

Hysteresis *

PVEO,
On/Off

PVEO-R,
On/Off

PVEM, Prop.
med.

max.

0.235 s

0.41 s

0.700 s

rated

0.180 s

0.35 s

0.450 s

min.

0.120 s

0.25 s

0.230 s

max.

0.175 s

0.33 s

0.175 s

rated

0.090 s

0.27 s

0.090 s

min.

0.065 s

0.25 s

0.065 s

max.

0.700 s

rated

0.450 s

min.

0.230 s

max.

0.700 s

rated

0.450 s

min.

0.230 s

rated

20%

* Hysteresis (control signal/spool travel) is indicated at rated voltage and f = 0.02 Hz for one cycle.
(one cycle = neutral full A full B neutral)
Technical data for PVEA, PVEH and PVES
PVEA, PVEH and PVES
Supply voltage UDC

rated

11 V to 32 V

range

11 V to 32 V

max. ripple

5%

Current consumption at rated voltage

PVEH/PVES (PVEA)

0.57 (33) A @ 12 V

Signal voltage

neutral

0.5 x UDC

A-port B-port

0.25 UDC to 0.75 UDC

Signal current at rated voltage

0.25 mA to 0.70 mA

Input impedance in relation to 0.5 UDC

12 K

Input capacitor

0.3 (17) A @ 24 V

100 F

Power consumption

PVEH/PVES (PVEA)

7 (3.5) W

(PVEH/PVES)

Max. load

100 mA

Active

Reaction time at fault

500 ms (PVEA: 750 ms)

Passive

Reaction time at fault

250 ms (PVEA: 750 ms)

520L0344 Rev HE Feb 2014

60 mA

29

Technical Information

PVG 32 Proportional Valve Group

PVG 32 technical data

Reaction time for PVEA, PVEH and PVES


Supply voltage

Function

Disconnected by means
of neutral switch

Reaction time from neutral


position to max. spool travel

Disconnected by means
of neutral switch

Constant voltage

Constant voltage

Reaction time from max. spool


travel to neutral position

Reaction time from neutral


position to max. spool travel

Reaction time from max. spool


travel to neutral position

Hysteresis *

PVEA
Prop. fine
s

PVEH
Prop. high
s

PVES
Prop. super
s

max.

0.50

0.23

0.23

rated

0.32

0.15

0.15

min.

0.25

0.12

0.12

max.

0.55

0.175

0.175

rated

0.40

0.09

0.09

min.

0.30

0.065

0.065

max.

0.50

0.20

0.20

rated

0.32

0.12

0.12

min.

0.25

0.05

0.05

max.

0.25

0.10

0.10

rated

0.20

0.09

0.09

min.

0.15

0.065

0.065

rated

2%

4%

0%

Typical hysteresis characteristics for control signal vs spool travel af different PVE types*
Spool position

* Hysteresis (control signal/spool travel) is indicated at rated voltage and f = 0.02 Hz. (one cycle = neutral
full A full B neutral)
The following technical data are from typical test results. For the hydraulic system a mineral based
hydraulic oil with a viscosity of 21 mm2/s [102 SUS] and a temperature of 50 C [122 F] were used.
Pilot oil consumption PVEA, PVEH, PVES, PVEO and PVEM
Function

PVEA
Prop. fine

PVEH
Prop. high

PVES
Prop. super

PVEO
ON/OFF

PVEM
Prop. medium

Neutral without
supply voltage

0.3 l/min
[0.079 US gal/min]

Locked with supply


voltage

0.4 l/min
[0.106 US gal/min]

0.1 l/min
[0.026 US gal/min]

0.1 l/min
[0.026 US gal/min]

0.1 l/min
[0.026 US gal/min]

0.1 l/min
[0.026 US gal/min]

30

520L0344 Rev HE Feb 2014

Technical Information

PVG 32 Proportional Valve Group

PVG 32 technical data

Pilot oil consumption PVEA, PVEH, PVES, PVEO and PVEM (continued)
Function

PVEA
Prop. fine

PVEH
Prop. high

PVES
Prop. super

PVEO
ON/OFF

PVEM
Prop. medium

0.7 l/min
[0.185 US gal/min]

0.8 l/min
[0.211 US gal/min]

0.7 l/min
[0.185 US gal/min]

0.5 l/min
[0.132 US gal/min]

One actuation (neutral 2 cm3 [0,12 in3]


max) with supply
voltage
Continuous actuations 1 l/min
with supply voltage
[0.26 US gal/min]
Oil viscosity *

Oil temperature

recommended range

12 - 75 mm2/s

[65 - 347 SUS]

minimum

4 mm2/s

[39 SUS]

maximum

460 mm2/s

[2128 SUS]

recommended range

30 - 60C

[86 -140F]

minimum

-30C

[-22F]

90C

[194F]

Ambient temperature recommended range

maximum

-30 60C

[-22 140F]

Filtering in the hydraulic system

Max. allowed degree of contamination: 23/19/16


(ISO 4406, 1999 version)

* Max. start up viscosity 2500 mm2/s.


PVPX, electrical LS unloading valve
PVPX technical data
Max. operating pressure

350 bar [5075 psi]

Enclosure to IEC 529

IP65

Max. pressure drop at an oil flow of 0.1 l/min [2.6 US gal/min]

2 bar [30 psi]

Oil temperature
(Inlet)

Recommended temperature

30C to 60C [86F to 140F]

Min. temperature

-30C [-22F]

Max. temperature

90C [194F]

Max. coil surface temperature

155C [311F]

Ambient temperature

-30C to 60C [-22F to 140F]

Oil viscosity

Operating range

12 to 75 mm2/s [65 to 347 SUS]

Min. viscosity

4 mm2/s [39 SUS]

Max. viscosity

460 mm2/s [2128 SUS]

Response time for LS pressure relief

300 ms

Rated voltage

12 V

Max. premissible deviation from rated supply voltage

10%

Current consumption at rated voltage at 22C [72F] coil temperature

1.55 A

0.78 A
0.5 A

Power consumption

at 110C [230F] coil temperature

1A

at 22C [72F] coil temperature

19 W

at 110C [230F] coil temperature

12 W

520L0344 Rev HE Feb 2014

24 V

31

Technical Information

PVG 32 Proportional Valve Group

Electrical actuation
Electrical control of PVG
Valve actuation with electrical actuators has been supported by Danfoss for a long time. The actuation
can be controlled directly by joystick, by a PLUS+1 controller or by a broad range of third part
controllers. The actuator controls the spool by building up pilot oil pressure on the end of the spool. For
the PVE a pilot oil pressure between 10 and 15 bar is used. For the PVHC a pilot oil pressure between 20
and 25 bar is used.
PVG with PVE

Valve section with naming - standard mounted - seen from PVP


P -> A
Pilot oil supply

Oil
B port

PVE

A port
PVB

PVM

Electronics

Neutral spring

NC Solenoid valves
NO solenoid valves

LVDT

PVBS
V310072.B

A detailed description of the variants is presented in:


PVE-Series 4 for PVG 32, PVG 100 and PVG 120 Technical Information, 520L0553, covers all analogue PVE
PVEO, PVEH, PVES, PVEA, PVEM, PVEU, PVEP and the current controlled PVHC.
Electrohydraulic Actuator PVED-CC Series 4 Technical Information, 520L0665, covers the ISOBUS/SAE
J1939 CAN controlled PVED-CC.
Electrohydraulic Actuator PVED-CX Series 4 Technical Information, 11070179, covers the IEC61508 SIL2
certified CANopen controlled PVED-CX.

32

520L0344 Rev HE Feb 2014

Technical Information

PVG 32 Proportional Valve Group

Electrical actuation
PVE characteristic - control by voltage

PVEP

control range
2.5V

5V

7.5V

PVEU

fixed

Closed loop control


The PVE variants PVEA/H/M/S/U/P and the PVED-CC/-CX has a closed loop control supported by a spool
position sensor that ensures integrity towards flow forces and oil viscosity.
Hysteresis for PVE variants*
Spool position

Hysteresis (Control signal /spool travel) is indicated at rated voltage and f = 0.02 Hz for one cycle (one
cycle = neutral full A full B neutral).
The values are typical test data for exact ranges, see PVE Technical Information, 520L0553.

520L0344 Rev HE Feb 2014

33

Technical Information

PVG 32 Proportional Valve Group

Electrical actuation

PVEU is available with PVEH and PVES hysteresis


PVEP, PVED-CC and PVED-CX are available with PVES hysteresis

The standard PVEs are proportional activated actuator except PVEO which is on/off.
The PVEs have fault-monitoring.
Fault monitoring overview
Type

Fault
monitoring

Delay before error


out

Error mode

Error output Fault output


status
on PVE 1)

LED light

Memory
(reset
needed)

PVEO
PVEM

No fault
monitoring

PVEA
PVEH
PVEP
PVES
PVEU

Active

500 ms
(PVEA: 750 ms)

No fault

Low

<2V

Green

Input signal faults

High

UDC

Flashing red

Yes

Transducer (LVDT)

Constant red

Close loop fault


Passive

250 ms
(PVEA: 750 ms)

No fault

Low

<2V

Green

Input signal faults

High

~UDC

Flashing red

No

Transducer (LVDT)

Constant red

Close loop fault


PVE
Float
six pin

Active

500 ms

Float not active

750 ms

Float still active

High

~UD

Constant red

1) Measured between fault output pin and ground.


PVEO
The PVEO is an on/off activated actuator. The PVEO has not fault-monitoring.
Variants:

Power supply:

PVEO-R with a ramp delayed actuation


PVEO-DI with direction indication feedback
Anodized aluminum block
ATEX certified

AMP version

12 V
24 V

Connectors:

AMP
DIN/Hirshmann
Deutsch

DIN/Hirschmann version

Deutsch version

PVEO/PVEO-R

U DC

U DC

157-502.11

34

520L0344 Rev HE Feb 2014

Yes

Technical Information

PVG 32 Proportional Valve Group

Electrical actuation
PVEM
The PVEM is a proportional activated actuator. The PVEM has not fault-monitoring.
Variants:

PVEM -R with a ramp delayed actuation


PVEM for float in B-direction and max. flow B at 4.8 mm

Power supply: 12 / 24 V
Connectors:DIN/Hirshmann
PVEA, PVEH, PVES, PVEU
Variants:

Power supply: 11 32 V

Connectors:

-F for float in B-direction


max. flow B at 4.8 mm
-F for float in A-direction
max. flow A at 5.5 mm
PVES-SP with spool position feedback
Anodized aluminum block
ATEX certified

AMP version

AMP
DIN/Hirshmann
Deutsch

DIN/Hirschmann version

Deutsch version

LED

PVEA, PVEH, PVES, PVEU


and PVEH float A

PVEH, PVEM, PVES,


PVEH float B and PVEM float B

PVEA, PVEH, PVES, PVEU


and PVEH float B

PVEP
The PVEP is controlled with separate PWM control
signals for A and B direction.

Deutsch version
PVES-SP

The PVEP has hysteresis and fault monitoring like


the PVES.
Power supply: 11 32 V
Connector: Deutsch

LED
Not
connected
Error
Us

Spool position

3
2
1

4
5
6
UDC

PVED-CC and PVED-CX


The CAN controlled PVE embedded microcontrollers support the same high spool controllability as the
PVES and additional has high quality feedbacks, safety monitoring and detailed diagnostics.

520L0344 Rev HE Feb 2014

35

Technical Information

PVG 32 Proportional Valve Group

Electrical actuation
PVED has digital communication, that allows a wide range of feedback, setpoint and highly costumized
settings. CAN bus serial communication makes wiring much easier. Only one cable per PVG group.
Power supply: 11 32 V PVE with Deutsch connector incl. female connector
Connectors:

Deutsch (PVED-CC)
AMP (PVED-CC and
PVED-CX)

For more information on PVED please see the PVED-CC, Series 4 Technical Information, 520L0665.
PVHC
For PVG controlled by PVHC, hysteresis is influenced by lever (PVM). The PVHC control is done by dual
Pulse Width Modulated (PVM) high current supply 100-400 Hz PWM control signals.
The PVHC does not have neither fault monitoring nor internal closed loop control of the spool.
Power supply:

12 V
24 V

PVHC with AMP version


5.7
[0.224]

44.4 [1.748]

PVHC with Deutsch version


5.7
[0.224]

5.7
[0.224]

Deutsch
AMP

26.75
[1.053]

26.75
[1.053]

74.0
[2.913]
74.0
[2.913]

16.5
[0.650]

5.75
[0.226]
P301 123

520L0344 Rev HE Feb 2014

92.25
[3.631]

92.25
[3.631]

16.5
[0.650]

36

5.7
[0.224]

33.0 [1.299]

33.0 [1.299]

Connectors:

44.4 [1.748]

5.75
[0.226]
P301 124

Technical Information

PVG 32 Proportional Valve Group

Electrical actuation
PVHC characteristic - Spool stroke vs current
Spool stroke, mm
7
6
5
Ideal curve
4
3

Hysteresis

500/1000 mA

280/560 mA

280/560 mA

500/1000 mA

1600

@ 12V

800

1400
700

1200
600

1000

Current in mA

500

800
400

600
300

400
200

200

100

200
100

400
200

600
300

800
400

1000
500

1200
600

1400
700

800

1600

@ 24V

V310 000.A

PVHC current response and hysteresis @ 25 bar Pp, 21 ctS, 25 C. The ideal curve is determined by the
main spool neutral spring. The PVHC has high hysteresis. The hysteresis is affected by viscosity, friction,
flow forces, dither frequency and modulation frequency. The spool position will shift when conditions are
changed e.g. temperature change.

520L0344 Rev HE Feb 2014

37

Technical Information

PVG 32 Proportional Valve Group

Technical characteristics
General
The characteristics in this catalog are typical measured values. During measuring a mineral based
hydraulic oil with a viscosity of 21 mm2/s [102 SUS] at a temperature of 50C [122F] was used.
PVP, pump side module
Pressure relief valve characteristic in PVP
The pressure relief valve is set at an oil flow of 15 l/min [4.0 US gal/min].
Setting range:

30 to 350 bar [435 to 5075 psi] with PVSI end plate


30 to 300 bar [435 to 4351 psi] with PVS end plate

Pressure relief valve characteristic

Neutral by-pass pressure drop characteristic (open


center)

PVB, basic modules oil flow characteristics


The oil flow for the individual spool depends on:

38

type of basic module (with/without compensation)


type of pump (fixed or variable displacement).

520L0344 Rev HE Feb 2014

Technical Information

PVG 32 Proportional Valve Group

Technical characteristics
Linear oil flow depending on spool type

US = Signal voltage; UDC = Supply voltage; 1 = First PVB after PVP; 8 = Eighth PVB after
Pressure-compensated PVB, open or closed center PVP
The oil flow is dependent on the supplied pump oil flow. The characteristics are plotted for a pump oil
flow, QP, corresponding to the rated max. spool oil flow, QN. Increasing the pump oil flow to 1,4 QN will
give the same oil flow on the eighth as on the first basic module.
Please note, the letters AA, A, B, etc. denote spool types. The characteristic below is shown for spool
travel in both directions. All other characteristics are shown for spool travel in one direction only.

520L0344 Rev HE Feb 2014

39

Technical Information

PVG 32 Proportional Valve Group

Technical characteristics
Progressive oil flow characteristic depending on spool type

PVM
PVM
PVE
PWM for PVEP/T
control range
157-61.im

US = Signal voltage; UDC = Supply voltage; 1 = First PVB after PVP; 8 = Eighth PVB after
PVB without pressure compensation, open center PVP
The spool flow is dependent on the supplied oil flow, QP.
The characteristics apply to supply oil flow of 130 l/min [34.3 US gal/min] with the actuation of one basic
module and the supply flow level.
If several basic modules are activated at the same time, the characteristic depends on the load pressure
of the actuated basic modules.

40

520L0344 Rev HE Feb 2014

Technical Information

PVG 32 Proportional Valve Group

Technical characteristics
Oil flow as a function of spool travel characteristic

Oil flow QA/B as a function of supplied pump oil flow (QP)


The pressure drop of any oil flowing back to tank (QP - QA/B) is read on the curve for neutral flow pressure
in PVP.
Characteristic for fully displaced flow control spools

520L0344 Rev HE Feb 2014

41

Technical Information

PVG 32 Proportional Valve Group

Technical characteristics
PVB without pressure compensation, closed center PVP

Set pressure difference between pump pressure and LS signal = 10 bar [145 psi].

Set pressure difference between pump pressure and LS signal = 20 bar [290 psi].

42

520L0344 Rev HE Feb 2014

Technical Information

PVG 32 Proportional Valve Group

Technical characteristics
The oil flow is dependent on the pressure difference between the pump pressure and the LS signal.
Normally the pressure difference is set at the LS pump regulator. Also take into consideration pressure
drop from the pump to the PVG valve group. e.g. long pipeline.
Oil flow characteristics for PVB at

@ pressure drop at max. main spool travel

@ pressure drop for open spool in neutral position

Load-independent, pressure-compensated

LS pressure limiting, pressure-compensated PVB

PVLP, shock and PVLA, suction valves


PVLP is set at an oil flow of 10 l/min [2.6 US gal/min]. The shock valve PVLP is designed to absorb shock
effects. Consequently, it should not be used as a pressure relief valve.
If the working function requires the use of a pressure relief valve, a PVB basic module with built-in LSA/B
pressure limiting valve should be used.

520L0344 Rev HE Feb 2014

43

Technical Information

PVG 32 Proportional Valve Group

Technical characteristics

PVLP, shock valve characteristic

Pressure build-up for pressure controlled spools


Max. oil flow can be reduced by about
50% without limitation of maximum
pressure by limiting the main spool
travel from 7 mm [0.28 in] to 5.5 mm
[0.22 in].

44

520L0344 Rev HE Feb 2014

PVLA, suction valve characteristic

Technical Information

PVG 32 Proportional Valve Group

Technical characteristics
Pressure control spool flow characteristics
Size A:

Size B:

Example 1

Size C:

Size D:

Example 2

Size E:

Examples of how to use the characteristics for pressure control spools


Example 1: Determining the oil flow

Example 2: Determining the spool size

Given:

Given:

520L0344 Rev HE Feb 2014

45

Technical Information

PVG 32 Proportional Valve Group

Technical characteristics
Example 1: Determining the oil flow

Example 2: Determining the spool size

Spool type B
Pressure setting PP: 160 bar [2320 psi]
Load pressure, LSA/B: 100 bar [1450 psi]

Max. oil flow, QA/B: 90 l/min [23.8 US gal/min]


Pressure setting PP: 150 bar [2175 psi]
Load pressure, PLSA: 125 bar [1810 psi]

Result:

Result:

Oil flow = 75 l/min [19.8 US gal/min]

D spool (see Pressure control spool flow


characteristics, size D)

Normally a smaller spool can be chosen with pressure control. It is our experience that the spool can be
one size smaller than with normal flow control.
Characteristics for float position main spools
Characteristic of oil flow, spool travel and voltage

8 mm [0.19 in] spool displacement in direction A gives max. oil flow to port A
8 mm [0.19 in] spool displacement in direction B gives max. oil flow to port B
8 mm [0.32 in] spool displacement in direction B gives completely open float position A/B T.

The spools have 4,8 mm spool travel in direction A and 8 mm travel in direction B:
For more information regarding electrical actuation of float spools please see PVE series 4 Technical
Information, 520L0553.

46

520L0344 Rev HE Feb 2014

Technical Information

PVG 32 Proportional Valve Group

Technical characteristics
Pressure drop A/B T at max. spool travel within the proportional range (4.8 mm) [0.19 in]

Spools D and E have the same opening area for forward flow and return flow.
Spool E can give 100 l/min [26.4 US gal/min] pressure compensated oil flow due to a higher pressure
drop across spool E. This occurs during spool actuation only.
Pressure drop A/B T in float position

520L0344 Rev HE Feb 2014

47

Technical Information

PVG 32 Proportional Valve Group

Hydraulic systems
Manually actuated PVG 32 fixed displ. pump
Example schematic of manually actuated PVG 32 fixed displacement pump

48

520L0344 Rev HE Feb 2014

Technical Information

PVG 32 Proportional Valve Group

Hydraulic systems
Electrically actuated PVG 32 variable displ. pump
Example schematic of electrically actuated PVG 32 variable displacement pump (electrical actuator, shock valves, relief valve)

520L0344 Rev HE Feb 2014

49

Technical Information

PVG 32 Proportional Valve Group

Other operating conditions


Oil
The main duty of the oil in a hydraulic system is to transfer energy. It must also lubricate the moving parts
in hydraulic components, protect them against corrosion, and transport dirt particles and heat out of the
system. It is therefore important to choose the correct oil with the correct additives. This gives normal
operation and long working life.
Mineral oil
For systems with PVG 32 valves Danfoss recommends the use of mineral-based hydraulic oil containing
additives: Type HLP (DIN 51524) or HM (ISO 6743/4).
Non-flammable fluids
Phosphate-esters (HFDR fluids) can be used without special precautions. However, dynamic seals must be
replaced with FPM (Viton) seals. Please contact the Danfoss Sales Organization if the PVG 32 valve is to be
used with phosphate-esters.
The following fluids should only be used according to agreement with the Danfoss Sales Organization
for:

Water-glycol mixtures (HFC fluids)


Water-oil emulsions (HFB fluids)
Oil-water emulsions (HFAE fluids)

Particle content, degree of contamination


Biodegradable oils
PVG 32 valves can be used in systems with rapeseed oil. The use of rapeseed oil is conditioned by:

complying with the demands on viscosity, water content, temperature and filtering etc. (see chapters
below and technical data).
adapting the operating conditions to the directions of the oil supplier.

Before using other biodegradable fluids, please consult the Danfoss organization. Oil filtration must
prevent particle content from exceeding an acceptable level, i.e., an acceptable degree of contamination.
Maximum contamination for PVG 32 is 23/19/16 (see ISO 4406. Calibration in accordance with the ACFTD
method). In our experience a degree of contamination of 23/19/16 can be maintained by using a filter
fineness as described in the next section.
For more information, please see the Danfoss literature:

Design Guidelines for Hydraulic Fluid Cleanliness Technical Information, 520L0467


Hydraulic Fluids and Lubricants Technical Information, 521L0463
Experience with Biodegradable Hydraulic Fluids Technical Information, 521L0465.

Filtration
Effective filtration is the most important precondition in ensuring that a hydraulic system performs
reliably and has a long working life. Filter manufacturers issue instructions and recommendations. It is
advisable to follow these.
System filters
Where demands on safety and reliability are very high a pressure filter with bypass and indicator is
recommended. Experience shows that a 10 m nominal filter (or finer) or a 20 m absolute filter (or finer)
is suitable. It is our experience that a return filter is adequate in a purely mechanically operated valve

50

520L0344 Rev HE Feb 2014

Technical Information

PVG 32 Proportional Valve Group

Other operating conditions


system. The fineness of a pressure filter must be selected as described by the filter manufacturer so that a
particle level of 23/19/16 is not exceeded. The filter must be fitted with pressure gauge or dirt indicator to
make it possible to check the condition of the filter. In systems with differential cylinders or accumulators
the return filter must be sized to suit the max. return oil flow. Pressure filters must be fitted to suit max.
pump oil flow.
Internal filters
The filters built into PVG 32 are not intended to filter the system but to protect important components
against large particles. Such particles can appear in the system as a result of pump damage, hose fracture,
use of quick-couplings, filter damage, starting up, contamination, etc. The filter in the electrical actuator
PVE protecting the solenoid valves has a mesh of 150 m. Bursting pressure drop for internal filters is 25
bar [360 psi].

520L0344 Rev HE Feb 2014

51

Technical Information

PVG 32 Proportional Valve Group

Dimensions
PVG 32 Dimensions

F: Shock and suction valve, PVLP


G: Pressure gauge connection: G, 12 mm [9/16-18, 0.5 in] deep
H: Plug for external pilot oil supply, PVPC: G, 12 mm [ 20, 0.47 in] deep
I: Electrical LS unloading valve, PVPX
J: LS connection: G, 12 mm [20; 0.47 in or 9/16-18, 0.5 in] deep
K: Fixing holes: M8 min. 10 [5/1618; 0.39 in] deep
L: Port A and B: G, 14 mm [7/8 14; 0.65 in] deep
M: LX connection: PVS; G 1/8, 10 mm [3/8 24; 0.39 in] deep and PVSI; G, 12 mm [ -20; 0.47 in] deep

52

520L0344 Rev HE Feb 2014

Technical Information

PVG 32 Proportional Valve Group

Dimensions
N: LS pressure limiting valve
O: Tank connection; G, 16 mm [1 1/16-12; 0.75 in] deep
P: Pressure relief valve
Q: Pump connection; G, 14 mm [7/8-14; 0.65 in] deep or G, 16 mm [1 1/16-12; 0.75 in] deep
R: LSA and LSB connections; G, 12 mm deep [9/16-18, 0.5 in] deep
S : Pp, pilot pressure connection G
PVB
L1
L2

10

11

12

mm

82

130

178

226

274

322

370

418

466

514

562

610

[in]

[3.23]

[5.12]

[7.01]

[8.90]

[10.79]

[12.68]

[14.57]

[16.46]

[18.35]

[20.24]

[562]

[610]

mm

140

189

238

287

336

385

434

483

527

576

622

670

in]

[5.51]

[7.44]

[9.37]

[11.30]

[13.23]

[15.16]

[17.09]

[19.02]

[20.95]

[22.87]

[622]

[670]

520L0344 Rev HE Feb 2014

53

Technical Information

PVG 32 Proportional Valve Group

Dimensions

44 [

110[4.33]
max.200.5[7.894]

6.5

1.73

85[3.35]

33[1.30]

P
V
M
D

~1
65[

2]

6.5[0.256]

7[0.28]

49.5[1.949]

P
V
H

7[0.28]

32[1.26]

85[3.35]
58.5[2.303]

45[1.77]

P
V
M
R
/
F

0]

A-A

60[2.36]

17[0.67]

7[0.28]

129[5.08]
95[3.74]

13[0.51]

85.5[3.366]

B-B

PVEO

107[4.21]

110[4.33]
max.290.50[11.437]

60[2.36]

89.5[3.524]

117[4.61]
7[0.28]

139[5.472]

C-C

PVEM/PVEH/
PVES

107[4.21]

110[4.33]
max.290.50[11.437]

60[2.36]

V310141.A

F : G 1/4, 12 mm deep [1/2 in - 20, 0.47 in deep]

54

520L0344 Rev HE Feb 2014

Technical Information

PVG 32 Proportional Valve Group

Dimensions
PVM, control lever positions
Base with an angle of 37.5

Base with an angle of 22.5

19.

19.5

19

19

.5

.5

37.5

67
.5
.5

97

.5

127

22.5

52

.5

82

.5

11

172.5

187.5

142.5

2.5

157.5

V310018.A
V310014.A

The angle of the handle is determined by which side of the handle that is mount towards the base. If a
22.5 angle is needed the "dot" on the handle is not visible. If 37.5 is needed the dot should be visible.
Surface treatment
The PVG valve has as standard, an untreated surface. In certain applications, depend on different factors,
such as: salty environment, large temperature changes, high humidity, rust can develope on the surface.
This will not affect the performance of the PVG valve group. To prevent/reduce rust development,
Danfoss recommend the PVG valve group to be painted. Rust on the surface is not seen as a valid
complaint issue, neither on painted or unpainted PVG valve groups.

520L0344 Rev HE Feb 2014

55

Technical Information

PVG 32 Proportional Valve Group

Modules symbols, description and code numbers


PVP, pump side modules
Symbol

Description
Open center pump side module for pumps
with fixed displacement.
For purely mechanically actuated valve
groups

Code number
P=G
T=G

157B5000

P = 7/814
T = 1 1/1612

157B5200

P, T = G

157B5100

P, T = 1 1/1612

157B5300

P=G
T=G

157B5001

P = 7/814
T = 1 1/1612

157B5201

For purely mechanically actuated valve


groups.

P, T = G

157B5101

P, T = 1 1/1612

157B5301

Open center pump side module for pumps


with fixed displacement.
With pilot oil supply for electrically actuated
valves.

P=G
T=G

157B5010

P = 7/814
T = 1 1/1612

157B5210

P, T = G

157B5110

P, T = 1 1/1612

157B5310

P=G
T=G

157B5011

P = 7/814
T = 1 1/1612

157B5211

P, T = G

157B5111

P, T = 1 1/1612

157B5311

P=G
T=G

157B5012

P = 7/814
T = 1 1/1612

157B5212

P, T = G

157B5112

P, T = 1 1/1612

157B5312

P=G
T=G

157B5013

P = 7/814
T = 1 1/1612

157B5213

P, T = G

157B5113

P, T = 1 1/1612

157B5313

Closed center pump side module for pumps


with vaiable displacement.

Closed center pump side module for pumps


with variable displacement.
With pilot oil supply for electrically actuated
valves.

Open center pump side module for pumps


with fixed displacement.
With pilot oil supply for electrically actuated
valves
Connection for electrical LS unloading valve,
PVPX (not incl.)

Closed center pump side module for pumps


with variable displacement
With pilot oil supply
Connection for electrical LS unloading valve,
PVPX (not incl.)

Connections:
P = G in; 14 mm deep or G in; 16 mm deep / LS, M = G in; 12 mm deep / T = G in; 16 mm deep.
P = 7/814; 0.65 in deep or 1 1/1612; 0.75 in deep / LS, M = 20; 0.47 in deep / T = 1 1/1612; 0.75 in
deep.

56

520L0344 Rev HE Feb 2014

Technical Information

PVG 32 Proportional Valve Group

Modules symbols, description and code numbers

PVP, pump side modules


Symbol

Description

Code number

Open center pump side module for pumps with fixed


displacement.
For mechanical actuated valves.
Connection for LS unloading valve, PVPX (not incl)

P, T = G

157B5102

Closed center pump side module for pumps with


vaiable displacement.
For mechanical actuated valves.
Connection for LS unloading valve, PVPX (not incl)

P, T = G

157B5103

Open center pump side module for pumps with fixed


displacement.
With pilot oil supply for electrical actuation and
connection for pilot oil pressure
Incl. check valve

P, T = G

157B5180

P, T = 1 1/1612
LS connection =
9/1618

157B5380

Closed center pump side module for pumps with


variable displacement.
With pilot oil supply for electrical actuation and
connection for pilot oil pressure
Incl. check valve

P, T = G

157B5181

P, T = 1 1/1612
LS connection =
9/1618

157B5381

Open center pump side module for pumps with fixed


displacement.
With pilot oil supply for hydraulic actuation and
connection for pilot oil pressure

P, T = G

157B5190

P, T = 1 1/1612
LS connection =
9/1618

157B5390

Closed center pump side module pumps with variable


displacement
With pilot oil supply for hydraulic actuation and
connection for pilot oil pressure

P, T = G

157B5191

P, T = 1 1/1612
LS connection =
9/1618

157B5391

Connections:
P, T = G in; 16 mm deep / LS, M = G in; 12 mm deep
P, T = 1 1/1612; 0.75 in deep / LS, M = 20; 0.47 in deep.

520L0344 Rev HE Feb 2014

57

Technical Information

PVG 32 Proportional Valve Group

Modules symbols, description and code numbers


PVB, basic modules
PVB, basic modules without adjustable LSA/B pressure limiting valves
Symbol

Description

No facilities for
shock valves A/B

Facilities for shock


valves A/B

Without load drop check valve and


pressure compensator.
Can be used where load holding
valves prevent oil from flowing
back through channel P.

G
14 mm deep

157B6000

157B6030

7/814
0.65 in deep

157B6400

157B6430

Load drop check valve.

G
14 mm deep

157B6100

157B6130

7/814
0.65 in deep

157B6500

157B6530

Load drop check valve.


LSA/B shuttle valve.
To be used with float position
spools.

G
14 mm deep

157B6136

7/814
0.65 in deep

157B6536

Non-damped compensator valve

G
14 mm deep

157B6200

157B6230

7/814
0.65 in deep

157B6600

157B6630

G
14 mm deep

11071832

7/814
0.65 in deep

Without compensator valve


LSA/B shuttle valve

V310411.A

58

Code number

520L0344 Rev HE Feb 2014

Technical Information

PVG 32 Proportional Valve Group

Modules symbols, description and code numbers

PVB, basic modules without adjustable LSA/B pressure limiting valves (continued)
Symbol

Description

Code number

With damped compensator valve

No facilities for
shock valves A/B

Facilities for shock


valves A/B

G
14 mm deep

157B6206

157B6236

7/814
0.65 in deep

11036629

11036630

PVB, basic modules with adjustable LSA/B pressure limiting valves


Symbol

Description

Code number
No facilities for
shock valves A/B

Facilities for
shock valves A/B

With non-damped
compensator valve
Adjustable LSA/B pressure
limiting valves
External LS connection port
A/B.
Also used for float position
spools

G
14 mm
deep

157B6203

157B6233

7/814
0.65 in
deep

157B6603

157B6633

Damped compensator valve


Adjustable LSA/B pressure
limiting valves
External LS connection port
A/B

G
14 mm
deep

157B6208

157B6238

7/814
0.65 in
deep

11036631

PVLP, shock and suction valve (fitted in PVB)


PVLP, shock/ and anti-cavitation valves
Code no.
157B....
Settings

2032

2050

2063

2080

2100

2125

2140

2150

2160

2175

2190

bar

32

50

63

80

100

125

140

150

160

175

190

psi

460

725

914

1160

1450

1813

2031

2175

2320

2538

2755

520L0344 Rev HE Feb 2014

59

Technical Information

PVG 32 Proportional Valve Group

Modules symbols, description and code numbers

PVLP, shock and suction valve


Symbol

Description
Shock and suction valve for port A and/or B.
(Not adjustable).
Lifetime 200.000 actuations.

PVLA, suction valve (fitted in PVB)


PVLA, suction valve
Symbol

Description

Code
number

Suction valve for port A and/or B.

157B2001

Plug for connecting the nonactive port to


tank, when using a single acting spool.

157B2002

PVM, mechanical actuation


PVM, mechanical actuation
Symbol

60

Description

Code number
with stop screws w/o stop screws

PVM, Standard, spring centered


Individual oil flow adjustment to ports A and B

157B3171

157B3191

Without actuation lever and base.


Shaft for mounting of actuation lever

157B3173

157B3193

PVM, as standard, witout actuation lever.


With base for mounting of actuation lever

157B3174

157B3194

PVM, Standard, spring. Individual oil flow


adjustment to ports A and B. (Anodized)

157B3184

520L0344 Rev HE Feb 2014

Technical Information

PVG 32 Proportional Valve Group

Modules symbols, description and code numbers

PVMD, cover for mechanical actuation


Symbol

Description

Material

Code No.

Anodized

PVMD, Cover for purely mechanically operated valve

aluminium

157B0001

no

aluminium

157B0009

yes

cast iron

157B0021

no

Description

Material

Code number

Anodized

PVMR, Friction detent

aluminium

157B0004

no

aluminium

157B0012

yes

cast iron

157B0024

Description

Material

Code number

Anodized

PVMF,
Mechanical float position lock

aluminium

157B0005

no

Description

Material

Code number

Anodized

PVH, Cover for Hydraulic actuation


PVH 9/16-18 UNF

aluminium

157B0007

no

aluminium

157B0010

yes

cast iron

157B0014

no

aluminium

157B0008

no

aluminium

157B0011

yes

cast iron

157B0016

no

PVMR, friction detent


Symbol

PVMF, mechanical float position


Symbol

PVH, hydraulic actuation


PVH, hydraulic actuation
Symbol

PVH, Cover for Hydraulic actuation


PVH G1/4

PVS, end plate


PVS, end plate
Symbol

Description

Mounting
threads

Code number

PVS, without active elements.


No connections

BSP

157B2000

SAE

157B2020

G 1/8 10 mm deep

BSP

157B2011

3/8 in - 24; 0,39 in deep

SAE

157B2021

V310062.A

LX

V310063.A

PVS, without active elements.


Max. intermittend LX pressure
250 bar [3625 psi]

520L0344 Rev HE Feb 2014

61

Technical Information

PVG 32 Proportional Valve Group

Modules symbols, description and code numbers

PVS, end plate (continued)


Symbol

Description

Mounting
threads

Code number

PVSI, without active elements


Without connections.

BSP

157B2014

SAE

157B2004

G 1/4 10 mm deep

BSP

157B2015

1/2 in - 20; 0,47 in deep

SAE

157B2005

V310062.A

LX

PVSI, without active elements


LX connections.
Max. intermittend LX pressure:
350 bar [5075 psi]

V310063.A

For mounting threats please see the chapter Dimensions.


PVAS, assembly kit
PVAS, assembly kit
Code no,
157B...

10

11

12

PVBs

8000

8001

8002

8003

8004

8005

8006

8007

8008

8009

8010

8061

8062

PVB + PVPVM -

8021

8022

8023

8024

8025

8026

8027

8028

8029

8030

8081

8082

Weight kg [lb] 0.1[0.2]

0.15
[0.3]

0.25
[0.6]

0.30
[0.7]

0.40
[0.9]

0.45
[1.0]

0.50
[1.1]

0.60
[1.3]

0.65
[1.4]

0.70
[1.6]

0.80
[1.7]

0.85
[1.8]

0.9 [2.0]

PVPX, electrical LS unloaded valve


PVPX, electrical LS unloaded valve
Symbol

Description

Code number

PVPX, Normally open:


LS pressure relieved with no signal to PVPX

12 V

157B4236

24 V

157B4238

PVPX, Normally closed:


LS pressure relieved with no signal to PVPX

12 V

157B4246

24 V

157B4248

PVPX, Normally open with manual override:


LS pressure relieved with no signal to PVPX
Manual override DE-selects LS-pump

12 V

157B4256

24 V

157B4258

Plug

157B5601

PVPC, plug for external pilot oil supply


PVPC, plug for external pilot oil supply
Symbol

Description
PVP,
Plug without check valve for open
or closed center

62

520L0344 Rev HE Feb 2014

Code number
G 1/2,
12 mm deep

157B5400

1/2 in - 20;
0.47 in deep

Technical Information

PVG 32 Proportional Valve Group

Modules symbols, description and code numbers

PVPC, plug for external pilot oil supply (continued)


Symbol

Description
PVP,
Plug with check valve for
open center

520L0344 Rev HE Feb 2014

Code number
G 1/2,
12 mm deep

157B5600

1/2 in - 20;
0.47 in deep

157B5700

63

Technical Information

PVG 32 Proportional Valve Group

Module selection chart


Standard FC spools
PVB is with LSA/B shuttle valve

Code number 157B....

PVB is without LSA/B shuttle valve

Press. compensated flow: l/min [US gal/min]

ISO symbol

Press. compensated flow l/min [US gal/min]

Symbol

F
E
D
C
B
130
100
65
40
25
[34.3] [26.4] [17.2] [10.6] [6.6]

A
10
[2.6]

AA
5 [1.3]

AA
A
5 [1.3] 10
[2.6]

B
25
[6.6]

C
D
E
F
40
65
100
130
[10.6] [17.2] [26.4] [34.3]

7026

7020

7025

7005

7000

7001

7002

7003

7004

7006

7105

7100

7101

7102

7103

7104

7106

7200

7201

7202

7203

7204

7301

7302

7303

7304

7401

7402

7403

7404

7406

7501

7502

7503

7504

7024

7023

7022

7021

4-way, 3-position
Closed neutral position
7126

7124

7123

7122

7121

7120

7125

4-way, 3-position
Throttled, open neutral position
-

3-way, 3-position
Closed neutral position, P A
-

3-way, 3-position
Closed neutral position, P B
-

7424

7423

7422

7421

4-way, 3-position
Throttled, A T in neutral position
-

7524

7523

7522

7521

4-way, 3-position
Throttled, B T in neutral position
-

7624

7623

7622

7621

7620

157-139.10

157-140.10

4-way, 4-position
Closed neutral position
Float P B F

64

520L0344 Rev HE Feb 2014

Technical Information

PVG 32 Proportional Valve Group

Module selection chart


Standard FC spools, hydraulic actuation
PVB is with LSA/B shuttle valve

Code number 157B....

Press. compensated flow: l/min [US gal/min]

ISO symbol

PVB is without LSA/B shuttle valve


Symbol

Press. compensated flow: l/min [US gal/min]

E
100
[26.4]

D
65
[17.2]

C
40
[10.6]

B
25
[6.6]

A
10
[2.6]

AA
5
[1.3]

AA
5
[1.3]

A
10
[2.6]

B
25
[6.6]

C
40
[10.6]

D
65
[17.2]

E
100
[26.4]

9024

9023

9022

9021

9020

9025

9005

9000

9001

9002

9003

9004

9105

9100

9101

9102

9103

9104

4-way, 3-position
closed neutral position
9124

9123

9122

9121

9120

9125

4-way, 3-position
Throttled open neutral position

FC spools for mechanical float position, PVMF


PVB is with LSA/B shuttle valve
Press. compensated flow: l/min [US gal/min]

Code number 157B....

PVB is without LSA/B shuttle valve

ISO symbol

Press. compensated flow l/min [US gal/min]

Symbol

F
E
D
C
B
130
100
65
40
25
[34.3] [26.4] [17.2] [10.6] [6.6]

A
10
[2.6]

AA
5
[1.3]

AA
5
[1.3]

A
10
[2.6]

B
25
[6.6]

C
D
E
F
40
65
100
130
[10.6] [17.2] [26.4] [34.3]

9820

9825

9824

9823

9822

9821

4-way, 4 position
Closed neutral position
PAF
-

9624

623

9622

9621

157-140.10

157-139.10

4-way, 4-position
Closed neutral position
Float P B F

FC spools for friction detent, PVMR


PVB is with LSA/B shuttle valve

Code number 157B....

Press. compensated flow: l/min [US gal/min]


E
100
[26.4]

D
65
[17.2]

C
40
[10.6]

B
25
[6.6]

A
10
[2.6]

ISO symbol

AA
5
[1.3]

520L0344 Rev HE Feb 2014

PVB is without LSA/B shuttle valve


Symbol

Press. compensated flow: l/min [US gal/min]


AA
5
[1.3]

A
10
[2.6]

B
25
[6.6]

C
40
[10.6]

D
65
[17.2]

E
100
[26.4]

65

Technical Information

PVG 32 Proportional Valve Group

Module selection chart

PVB is with LSA/B shuttle valve


9724

9723

9722

9721

Code number 157B....


9720

PVB is without LSA/B shuttle valve

9700

9701

9702

9703

9704

9710

9711

9712

9713

9714

4-way, 3-position
closed neutral position
9734

9733

9732

9731

9730

4-way, 3-position
Throttled open neutral position

FC spools with linear flow characteristic


PVB is with LSA/B shuttle valve

Code number 157B....

PVB is without LSA/B shuttle valve

Press. compensated flow: l/min [US gal/min]

ISO symbol

Press. compensated flow: l/min [US gal/min]

Symbol

F
E
D
C
B
130
100
65
40
25
[34.3] [26.4] [17.2] [10.6] [6.6]

A
10
[2.6]

AA
5
[1.3]

AA
5
[1.3]

A
10
[2.6]

B
25
[6.6]

C
D
E
F
40
65
100
130
[10.6] [17.2] [26.4] [34.3]

9750

9751

9752

9753

9754

9760

9761

9762

9763

9764

9794

9804

9774

9773

9772

9771

4-way, 3-position
Closed neutral position
-

9784

9783

9782

9781

4-way, 3-position
Throttled, open neutral position
-

4-way, 3-position
Throttled, A T in neutral position
-

4-way, 3-position
B T in neutral position

66

520L0344 Rev HE Feb 2014

Technical Information

PVG 32 Proportional Valve Group

Module selection chart


Standard PC spools
PVB is with LSA/B shuttle valve

Code number 157B....

Press. compensated flow: l/min [US gal/min]

ISO symbol

PVB is without LSA/B shuttle valve


Symbol

Press. compensated flow: l/min [US gal/min]

E
100
[26.4]

D
65
[17.2]

C
40
[10.6]

B
25
[6.6]

A
10
[2.6]

AA
5
[1.3]

AA
5
[1.3]

A
10
[2.6]

B
25
[6.6]

C
40
[10.6]

D
65
[17.2]

E
100
[26.4]

7033

7032

7031

7030

7035

7015

7010

7011

7012

7013

7115

7110

7111

7112

7113

7040

7041

7042

7043

7044

7050

7051

7052

7053

7054

7150

7151

7152

7153

7154

7150

7151

7152

7153

7154

7452

7453

4-way, 3-position
Closed neutral position, PC A and B
7134

7133

7132

7131

7130

7135

4-way, 3-position Throttled, open neutral position,


PC A and B
7064

7063

7062

7061

4-way, 3-position
Closed neutral position, PC A
7074

7073

7072

7071

4-way, 3-position
Closed neutral position, PC B
7164

7163

7162

7161

4-way, 3-position
Throttled, open neutral position, PC A
7174

7173

7172

7171

4-way, 3-position
Throttled, open neutral position, PC B
-

7473

7472

7471

7470

4-way, 3-position
Throttled, A T neutral position, PC B

520L0344 Rev HE Feb 2014

67

Technical Information

PVG 32 Proportional Valve Group

Module selection chart

PVB is with LSA/B shuttle valve


-

7563

7562

Code number 157B....


-

PVB is without LSA/B shuttle valve

7541

7542

7543

4-way, 3-position
Throttled, B T neutral position , PC A

Standard PC spools, hydraulic actuation


PVB is with LSA/B shuttle valve

Code number 157B....

Press. compensated flow: l/min [US gal/min]

ISO symbol

PVB is without LSA/B shuttle valve


Symbol

Press. compensated flow: l/min [US gal/min]

E
100
[26.4]

D
65
[17.2]

C
40
[10.6]

B
25
[6.6]

A
10
[2.6]

AA
5
[1.3]

AA
5
[1.3]

A
10
[2.6]

B
25
[6.6]

C
40
[10.6]

D
65
[17.2]

E
100
[26.4]

9015

9010

9011

9012

9042

9043

9044

9052

9053

9054

4-way, 3-position
Closed neutral position, PC A and B
-

4-way, 3-position
Closed neutral position, PC A
-

4-way, 3-position
Closed neutral position, PC B

68

520L0344 Rev HE Feb 2014

Technical Information

PVG 32 Proportional Valve Group

Module selection chart


PVB, basic valves

0
0
1-13
16

14
a
15

V310168.A

PVB, basic valves


Description

No facilities for shock valves A and B

Facilities for shock valves A and B

78 - 14 UNF

78 - 14 UNF

Without compensator /check valve

157B6000

157B6400

157B6030

157B6430

With check valve

157B6100

157B6500

157B6130

157B6530

With check valve and LSA/B shuttle valve

157B6136

157B6536

With compensator valve

157B6200

157B6600

157B6230

157B6630

520L0344 Rev HE Feb 2014

69

Technical Information

PVG 32 Proportional Valve Group

Module selection chart

PVB, basic valves (continued)


Description

No facilities for shock valves A and B

Facilities for shock valves A and B

78 - 14 UNF

78 - 14 UNF

With damped compensator valve

157B6206

157B6236

With compensator valve, LSA/B relief valve and LSA/B shuttle


valve

157B6203

157B6603

157B6233

157B6633

With damped compensator valve,


LSA/B relief valve and LSA/B shuttle valve

157B6208

157B6238

Weight

3.1 [6.8]

kg [lb]

3.0 [6.6]

PVPC, plugs
Description

in - 20

Weight
kg

[lb]

External pilot supply

157B5400

0.05

0.1

External pilot supply incl. check valve

157B5600

157B5700

0.05

0.1

PVM, mechanical actuation


Description

Alu

Alu anodized

Cast iron

Angle

with stop screws

without stop
screws

with stop screws

with stop screws

157B3171

157B3191

157B3184

157B3161

22,5/37,5

Standard with base, without arm and button 157B3174

157B3194

22,5/37,5

Standard without base, without arm and


button

157B3173

157B3193

157B3186

Weight kg [lb]

0.4 [0.9]

Standard

0.8 [1.8]

PVAS, assembly kit


Code no. 0
157B....

10

11

12

PVBs

8000

8001

8002

8003

8004

8005

8006

8007

8008

8009

8010

8061

8062

PVB +
PVPVM

8021

8022

8023

8024

8025

8026

17B8027 8028

8029

8030

8081

8082

Weight
kg [lb]

0.1 [0.2]

0.15 [0.3] 0.25 [0.6] 0.30 [0.7] 0.40 [0.9] 0.45 [1.0] 0.50 [1.1] 0.60 [1.3] 0.65 [1.4] 0.70 [1.6] 0.80 [1.7] 0.85 [1.8] 0.9 [2.0]

PVP, pump side module


PVP, pump side module
Description

Open
center

70

Without pilot supply

With pilot supply

for PVE

for PVE with


for PVE
facilit. for PVPX

for PVE and


facilit. for
PVPX

for PVE and pilot


oil pressure takeoff

for PVH and pilot


oil pressure takeoff

P = G1/2, T = G3/4

157B5000

157B5010

157B5012

P = 7/8 -14, T = 11/16 -12

157B5200

157B5210

157B5212

520L0344 Rev HE Feb 2014

Technical Information

PVG 32 Proportional Valve Group

Module selection chart

PVP, pump side module (continued)


Description

Without pilot supply


for PVE

for PVE with


for PVE
facilit. for PVPX

for PVE and


facilit. for
PVPX

for PVE and pilot


oil pressure takeoff

for PVH and pilot


oil pressure takeoff

157B5100

157B5102

157B5110

157B5112

157B5180

157B5190

P = 1 1/16 -12, T = 11/16 -12 157B5300

157B5310

157B5312

157B5380

157B5390

P = G1/2 , T = G3/4,

157B5001

157B5011

157B5013

P = 7/8 -14, T = 11/16 -12

157B5201

157B5211

157B5213

P = G3/4, T = G3/4,

157B5101

157B5103

157B5111

157B5113

157B5181

157B5191

157B5311

157B5313

157B5381

157B5391

P = G3/4, T = G3/4
Closed
center

P = 11/16 -12, T = 1 1/16 -12 157B5301


Weight

With pilot supply

kg [lb]

3 [6.6]

PVPX, electrical LS pressure relief valves


Description/
Supply voltage
Normally open
Normally closed
Normally open with manual override

Code No. Hirsch.

Code No.
AMP

Weight
kg [lb]

12 V

157B4236

157B4981

0.3 [0.7]

24 V

157B4238

157B4982

12 V

157B4246

157B4983

24 V

157B4248

157B4984

12 V

157B4256

157B4985

24 V

157B4258

157B4986

Plug

157B5601

0.06 [.13]

PVS and PVSI, end plate


Description

BSP

SAE

Weight
kg [lb]

PVS, without connections

157B2000

157B2020

0.5 [1.1]

PVS, with LX connection


G 1/8 [3/8 -24 UNF]

157B2011

157B2021

PVSI, without connections

157B2014

157B2004

PVSI, with LX connections


G 1/4 [1/2 -20 UNF]

157B2015

157B2005

1.7 [3.6]

PVLP, shock/ and anti-cavitation valves


Code no.
Settings

157B203
2

157B205
0

157B206
3

157B208
0

157B210
0

157B212
5

157B214
0

157B215
0

157B216
0

157B217
5

157B219
0

bar

32

50

63

80

100

125

140

150

160

175

190

psi

460

725

914

1160

1450

1813

2031

2175

2320

2538

2755

157B221
0

157B223
0

157B224
0

157B225
0

157B226
5

157B228
0

157B230
0

157B232
0

157B235
0

157B238
0

157B240
0

bar

210

230

240

250

265

280

300

320

350

380

400

psi

3045

3335

3480

3625

3845

4061

4351

4641

5075

5511

5801

Code no.
Settings

520L0344 Rev HE Feb 2014

71

Technical Information

PVG 32 Proportional Valve Group

Module selection chart


PVE, electrical actuation
PVE, electrical actuation
Description

Code No.
Hirsch

AMP

Deut.

12 V

157B4216

157B4901

157B4291

24 V

157B4228

157B4902

157B4292

12 V

157B4217

157B4903

24 V

157B4229

157B4904

PVEM, prop. medium


Standard

12 V

157B4116

24 V

157B4128

PVEM, prop. medium Float


>B

12 V

157B4416

24 V

157B4428

PVEA, active fault mon.


PVEA, passive fault mon.

157B4734
157B4735

157B4792
-

PVEA-DI, active fault mon.


PVEA-DI, passive fault mon.

157B4736
157B4737

157B4796
-

PVEH active fault mon.


PVEH passive fault mon.

157B4032
157B4033

157B4034
157B4035

157B4092
157B4093

PVEH float > B, act. fault


PVEH float > A, act. fault

157B4332
-

157B4338

157B4392
-

PVEH- DI active fault mon.


PVEH - DI passive fault mon.

157B4036
157B4037

157B4096
-

PVES, active fault mon.


PVES, passive fault mon.

157B4832
157B4833

157B4834
157B4835

157B4892
-

PVEO, on-off
PVEO-R, on/off

Weight
kg [lb]
0.6 [1.3]

0.9 [2.0]
1.0 [2.2]
0.9 [2.0]

1.0 [2.2]

PVMD, PVMR, PVMF, PVH covers


Description

Code No.

Material

Anodized

Weight
kg [lb]

PVMD
Cover for PVB

PVMR
(Friction Detent)

157B0001

aluminium

157B0009
157B0021

cast iron

N/A

0.9 [2.0]

157B0004

aluminium

no

0.3 [0.6]

157B0012

yes
cast iron

N/A

157B0005

aluminium

no

Hydraulic actuation PVH 9/16-18 UNF 157B0007

aluminium

no

157B0010
Hydraulic actuation PVH G1/4

157B0014

cast iron

N/A

157B0008

aluminium

no

157B0016

0.2 [0.4]

yes

157B0011

520L0344 Rev HE Feb 2014

0.1 [0.2]

yes

157B0024
PVMF
(Mech. float position)

72

no

yes
cast iron

N/A

0.9 [2.0]

Technical Information

PVG 32 Proportional Valve Group

Module selection chart

PVLA, anti-cavitation valve


Description

Code No.

Weight
kg

[lb]

Plug A or B

157B2002

0.04

0.09

Valve A or B

157B2001

0.05

0.1

520L0344 Rev HE Feb 2014

73

Technical Information

PVG 32 Proportional Valve Group

Order specification

An order form for PVG 32 hydraulic valve is shown on the next page.
The form can be obtained from the Danfoss Sales Organization.
Both the module selection chart on the previous pages and the order form are divided into fields 0,
1-1-12, 13, 14, 15, a, b, and c.
Each module has its own field:
0:

Pump side module PVP


Plug for external pilot oil supply PVPC
Electrical LS unloading valve PVPX

1-12: Basic valves PVB


13: Main spool PVBS
a: Mechanical actuator PVM (or PVE when option mounted)
c:

Cover for mechanical actuation PVMD


Cover for hydraulic actuation PVH
Electrical actuators PVE (or PVM when option mounted)

b:

Shock and suction valve PVLP


Suction valve PVLA

14: End plate PVS


15: Assembly kit PVAS
Please state

Code numbers of all modules required


Required setting (P) for pump side module
Required setting of LSA/B pressure limiting valves, see pressure setting guidance below.

Standard and option assembly


The PVG 32 valve group is assembled the way the module selection chart shows if the code number for
PVM is written in field 'a', and the code number for PVMD, PVE or PVH in field 'c'.
The valve group is assembled so that the mechanical actuator is mounted on the opposite end of the
basic module, if the code number for PVM is written in field 'c' of the order form and the code numbers
for PVMD, PVE or PVH in field 'a'.
Reordering
The space at the top right-hand corner of the form is for Danfoss to fill in. The code number for the whole
of the specified valve group (PVG No.) is entered here.
In the event of a repeat order all you have to do is enter the number Danfoss has given on the initial
confirmation of order.
Pressure setting limits
The maximum setting pressure for the pressure limiting valves LSA or LSB depends on the chosen
pressure setting for shock valve PVLP. The maximum values recommended to avoid interaction can be
read in the following table.

74

520L0344 Rev HE Feb 2014

Technical Information

PVG 32 Proportional Valve Group

Order specification
The figures in the table have been calculated according to the following expressions:

PVLP 150 bar: LSA/B 0.8 PPVLP


PVLP >150 bar: PPVLP - LSA/B 30 bar.

Max. pressure setting of LSA and LSB valves relative to PVLP shock valve
Pressure
setting
for PVLP

bar 32

50

63

80

100

125

140

150

160

175

190

210

230

240

250

265

280

300

320

350

380

400

psi

72
5

91
4

11
60

145
0

181
3

203
1

217
5

232
0

283
8

275
5

304
5

333
5

348
0

362
5

384
3

406
1

435
1

464
1

507
5

551
1

580
1

40

50

64

80

100

112

120

130

145

160

180

200

210

220

235

250

270

290

320

350

370

58
0

72
0

93
0

116
0

145
0

162
5

174
0

188
5

210
0

232
0

261
0

290
0

304
5

319
0

340
8

362
5

391
5

420
5

464
1

507
5

536
6

46
0

Max. for LSA/B bar psi

Min. for LSA/B

30 bar [435 psi]

520L0344 Rev HE Feb 2014

75

Technical Information

PVG 32 Proportional Valve Group

Order specification
PVG 32 order specification form

Separate specification pads are available under the literature no. 520L0515.

76

520L0344 Rev HE Feb 2014

Technical Information

PVG 32 Proportional Valve Group

520L0344 Rev HE Feb 2014

77

Technical Information

PVG 32 Proportional Valve Group

78

520L0344 Rev HE Feb 2014

Technical Information

PVG 32 Proportional Valve Group

520L0344 Rev HE Feb 2014

79

Products we oer:

Bent Axis Motors


Closed Circuit Axial Piston

Danfoss Power Solutions is a global manufacturer and supplier of high-quality hydraulic and
electronic components. We specialize in providing state-of-the-art technology and solutions that
excel in the harsh operating conditions of the mobile o-highway market. Building on our extensive
applications expertise, we work closely with our customers to ensure exceptional performance for a
broad range of o-highway vehicles.

Displays
Electrohydraulic Power

We help OEMs around the world speed up system development, reduce costs and bring vehicles to
market faster.
Danfoss Your Strongest Partner in Mobile Hydraulics.

Pumps and Motors

Steering

Electrohydraulics

Go to www.powersolutions.danfoss.com for further product information.

Hydraulic Power Steering

Wherever o-highway vehicles are at work, so is Danfoss.

Integrated Systems

We oer expert worldwide support for our customers, ensuring the best possible solutions for
outstanding performance. And with an extensive network of Global Service Partners, we also provide
comprehensive global service for all of our components.

Joysticks and Control


Handles

Microcontrollers and

Please contact the Danfoss Power Solution representative nearest you.

Software

Open Circuit Axial Piston


Pumps

Orbital Motors
PLUS+1 GUIDE
Proportional Valves
Sensors
Steering
Transit Mixer Drives

Comatrol
www.comatrol.com
Schwarzmller-Inverter
www.schwarzmuellerinverter.com

Local address:

Turolla
www.turollaocg.com
Valmova
www.valmova.com
Hydro-Gear
www.hydro-gear.com
Daikin-Sauer-Danfoss
www.daikin-sauer-danfoss.com

Danfoss
Power Solutions US Company
2800 East 13th Street
Ames, IA 50010, USA
Phone: +1 515 239 6000

Danfoss
Power Solutions GmbH & Co. OHG
Krokamp 35
D-24539 Neumnster, Germany
Phone: +49 4321 871 0

Danfoss
Power Solutions ApS
Nordborgvej 81
DK-6430 Nordborg, Denmark
Phone: +45 7488 2222

Danfoss
Power Solutions
(Shanghai) Co. Ltd.
Building #22, No. 1000 Jin Hai Rd
Jin Qiao, Pudong New District
Shanghai, China 201206
Phone: +86 21 3418 5200

Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to
products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.

520L0344 Rev HE Feb 2014

www.danfoss.com

Danfoss A/S, 2014

You might also like