520l0344 Folletos
520l0344 Folletos
520l0344 Folletos
Technical Information
powersolutions.danfoss.com
Technical Information
Revision History
Table of Revisions
Date
Changed
Rev
Feb 2014
HE
Jan 2014
HD
Various changes
BA - HC
Jan 2005
New Edition
AA
Technical Information
Contents
General description
Safety in application
Function
Electrical actuation
Technical Information
Contents
PVHC................................................................................................................................................................................................... 36
Technical characteristics
Hydraulic systems
Dimensions
General...............................................................................................................................................................................................38
PVP, pump side module.............................................................................................................................................................. 38
Pressure relief valve characteristic in PVP........................................................................................................................38
PVB, basic modules oil flow characteristics.......................................................................................................................... 38
Pressure-compensated PVB, open or closed center PVP .......................................................................................... 39
PVB without pressure compensation, open center PVP.............................................................................................40
PVB without pressure compensation, closed center PVP.......................................................................................... 42
PVLP, shock and PVLA, suction valves...............................................................................................................................43
Pressure build-up for pressure controlled spools.........................................................................................................44
Pressure control spool flow characteristics.......................................................................................................................... 45
Examples of how to use the characteristics for pressure control spools...................................................................45
Characteristics for float position main spools..................................................................................................................... 46
Manually actuated PVG 32 fixed displ. pump.................................................................................................................. 48
Electrically actuated PVG 32 variable displ. pump......................................................................................................... 49
Oil.........................................................................................................................................................................................................50
Mineral oil....................................................................................................................................................................................50
Non-flammable fluids............................................................................................................................................................. 50
Particle content, degree of contamination...........................................................................................................................50
Biodegradable oils....................................................................................................................................................................50
Filtration............................................................................................................................................................................................ 50
System filters.............................................................................................................................................................................. 50
Internal filters............................................................................................................................................................................. 51
PVM, control lever positions...................................................................................................................................................... 55
Surface treatment.......................................................................................................................................................................... 55
Order specification
Standard FC spools........................................................................................................................................................................64
Standard FC spools, hydraulic actuation...............................................................................................................................65
FC spools for mechanical float position, PVMF................................................................................................................... 65
FC spools for friction detent, PVMR.........................................................................................................................................65
FC spools with linear flow characteristic .............................................................................................................................. 66
Standard PC spools .......................................................................................................................................................................67
Standard PC spools, hydraulic actuation...............................................................................................................................68
PVB, basic valves.............................................................................................................................................................................69
PVP, pump side module.............................................................................................................................................................. 70
PVE, electrical actuation.............................................................................................................................................................. 72
Please state.......................................................................................................................................................................................74
Standard and option assembly................................................................................................................................................. 74
Technical Information
Contents
Reordering........................................................................................................................................................................................74
Pressure setting limits.................................................................................................................................................................. 74
PVG 32 order specification form...............................................................................................................................................76
Technical Information
General description
PVG 32 is a hydraulic load sensing valve designed to give maximum flexibility. From a simple load sensing
directional valve, to an advanced electrically controlled load-independent proportional valve.
The PVG 32 modular system makes it possible to build up a valve group to meet requirements precisely.
The compact external dimensions of the valve remain unchanged whatever combination is specified.
Features of PVG 32
Oil flow to an individual function is independent of the load pressure of this function
Oil flow to one function is independent of the load pressure of other functions
PVG modules
PVP, pump side modules
Technical Information
General description
PVB, basic modules
Interchangeable spools
Depending on requirements the basic module can be supplied with:
Actuation modules
The basic module is always fitted with mechanical actuator PVM and PVMD, which can be combined with
the following as required:
PVRE, PVRET
PVREL
PVRES
Prof 1
Prof 1 CIP
JS120
Technical Information
General description
Electrical and hydraulic remote control units
PVRE, electrical control unit, 162F
155N0003
155N0001
Prof 1, 162F
PVG 32 with open center PVP (fixed displ. pump) PVB with flow control spool
When the pump is started and the main spools in the individual basic modules (11) are in the neutral
position, oil flows from the pump, through connection P, across the pressure adjustment spool (6) to
tank. The oil flow led across the pressure adjustment spool determines the pump pressure (stand-by
pressure).
When one or more of the main spools are actuated, the highest load pressure is fed through the shuttle
valve circuit (10) to the spring chamber behind the pressure adjustment spool (6), and completely or
partially closes the connection to tank to maintain pump pressure.
Pump pressure is applied to the right-hand side of the pressure adjustment spool (6).
The pressure relief valve (1) will open should the load pressure exceed the set value, diverting pump flow
back to tank.
In a pressure-compensated basic module the compensator (14) maintains a constant pressure drop
across the main spool both when the load changes and when a module with a higher load pressure is
actuated.
With a non pressure-compensated basic module incorporating a load drop check valve (18) in channel P,
the check valve prevents return oil flow.
The basic module can be supplied without the load drop check valve in channel P for functions with overcenter valves.
The shock valves PVLP (13) with fixed setting and the suction valves PVLA (17) on ports A and B are used
for the protection of the individual working function against overload and/or cavitation.
An adjustable LS pressure limiting valve (12) can be built into the A and B ports of pressure-compensated
basic modules to limit the pressure from the individual working functions.
Technical Information
General description
Please see the sectional drawing below for better understanding of this example.
The LS pressure limiting valves save energy compared with the shock valves PVLP:
with PVLP all the oil flow to the working function will be led across the combined shock and suction
valves to tank if the pressure exceeds the fixed setting.
with LS pressure limiting valves an oil flow of about 2 l/min [0.5 US gal/min] will be led across the LS
pressure limiting valve to tank if the pressure exceeds the valve setting.
PVG 32 with closed center PVP (variable displ. pump) PVB with flow control spool
In the closed center version of PVP an orifice (5) and a plug (7) have been fitted instead of the plug (4).
This means that the pressure adjustment spool (6) will only open to tank when the pressure in channel P
exceeds the set value of the pressure relief valve (1).
In load sensing systems the load pressure is led to the pump control via the LS connection (8).
In the neutral position the pump load sense control sets the displacement so that leakage in the system is
compensated, to maintain the set stand-by pressure.
When a main spool is actuated the pump load sense control will adjust the displacement so that the set
differential pressure (margin) between P and LS is maintained.
The pressure relief valve (1) in PVP should be set at a pressure of approx. 30 bar [435 psi] above maximum
system pressure (set on the pump or external pressure relief valve).
Technical Information
General description
PVG 32 sectional drawing
1
4+5
A
LS
8
9
12 7
13
11
10
14
16
LS B
P LS A
17 15
A
19
18
20
V310106.A
10
11 Main spool
14 Pressure compensator
15 LS connection, port A
16 LS connection, port B
8 LS connection
9 LS signal
10 Shuttle valve
Technical Information
General description
Load sensing for variable displ. pump supply
The pump receives fluid directly from the reservoir through the inlet line. A screen in the inlet line
protects the pump from large contaminants.
The pump outlet feeds directional control valves such as PVG-32, hydraulic integrated circuits (HIC), and
other types of control valves.
The PVG valve directs and controls pump flow to cylinders, motors and other work functions. A heat
exchanger cools the fluid returning from the valve. A filter cleans the fluid before it returns to the
reservoir.
Flow in the circuit determines the speed of the actuators. The position of the PVG valve spool determines
the flow demand. A hydraulic pressure signal (LS signal) communicates demand to the pump control.
The pump control monitors the pressure differential between pump outlet and the LS signal, and
regulates servo pressure to control the swashplate angle. Swashplate angle determines pump flow.
Actuator load determines system pressure. The pump control monitors system pressure and will decrease
the swashplate angle to reduce flow if system pressure reaches the pump control setting.
A secondary system relief valve in the PVG valve acts as a back-up to control system pressure.
Pictorial circuit diagram
K/LFrame Series 45
open circuit axial
piston pump with
load sensing contro l
PVG 32
multi-sec tion
load
sensing
contro l
valve
Bi-directional
gear moto r
System pressur e
Servo pressur e
Heat exchanger
Reservoir
Filter
Actuator pressur e
Load sense pressur e
Actuator retur n
P101 658E
11
Technical Information
Safety in application
All makes and all types of control valves (incl. proportional valves) can fail, thus the necessary protection
against the serious consequences of function failure should always be built into the system. For each
application an assessment should be made for the consequences of pressure failure and uncontrolled or
blocked movements.
To determine the degree of protection that is required to be built into the application, system tools such
an FMEA (Failure Mode and Effect Analysis) and Hazard and Risk Analysis can be used.
FMEA IEC EN 61508
FMEA (Failure Mode and Effect Analysis) is a tool used for analyzing potential risks. This analytical
technique is utilized to define, identify, and prioritize the elimination or reduction of known and/or
potential failures from a given system before it is released for production. Please refer to IEC FMEA
Standard 61508.
Hazard and Risk Analysis ISO 12100-1 / 14121
This analysis is a tool used in new applications as it will indicate whether there are special safety
considerations to be met according to the machine directives EN 13849. Dependent on the determined
levels conformity this analysis will detirmine if any extra requirements for the product design,
development process, production process or maintenance, i.e. the complete product life cycle.
W Warning
All makes/brands and types of directional control valves inclusive proportional valves can fail and
cause serious damage. It is therefore important to analyze all aspects of the application.
Because the proportional valves are used in many different operation conditions and applications,
the manufacturer of the application is alone responsible for making the final selection of the products
and assuring that all performance, safety and warning requirements of the application are met.
The process of choosing the control system and safety levels is governed by the machine directives
EN 13849 (Safety related requirements for control systems).
Control system example
Example of a control system for manlift using PVE Fault monitoring input signals and signals from
external sensors to ensure the PLUS+1 main controllers correct function of the manlift.
12
Technical Information
Safety in application
Control system example
Legend:
1 Main power supply
2 Emergency stop/man present switch
3 HMI/Joystick control
4 Movement detection sensors
5 Main controller
6 PVG control valve
7 Hydraulic deactivation
13
Technical Information
Safety in application
Electrical block diagram for above illustration
HMI / Joystick
Joystick
neutral switch
Control
Signal
Supply
Main controller
Neutral Supply
Detection Control
Signal
Conditioning
Signal
Conditioning
Fault
Monitoring
PVE fault output
Failure
Detection
PVE
Hydraulic deactivation
P301 317
Warning
It is the responsibility of the equipment manufacturer that the control system incorporated in the
machine is declared as being in conformity with the relevant machine directives.
14
Technical Information
Safety in application
Typical wiring block diagram example
A
Emergency
stop
PVE 1
C
Man present
switch
PVEH
with AMP
connector
US
UDC2
1)
signal
neutral
OFF
Delay
PVE 2
C
PVEH
with AMP
connector
US
UDC2
1)
signal
neutral
Error
OFF
Delay
E1
Error
E2
2) Alarm
logic
Output
OR
3) Memory
AND
high=on
low=off
Hydraulic
deactivation
P301 318
Warning
It is the responsebilty of the equipment manufacturer that the control system incorporated in the
machine is declared as being in confirmity with the relevant machine directives.
15
Technical Information
Safety in application
PVG32 Mainly used in system with fixed displacement pumps
16
Technical Information
Function
Load sensing controls
The LS control matches system requirements for both pressure and flow in the circuit regardless of the
working pressure. Used with a closed center control valve, the pump remains in low-pressure standby
mode with zero flow until the valve is opened. The LS setting determines standby pressure.
Typical operating curve
PC setting
Flow
Q max
Pressure
P101 968E
P101 967
Most load sensing systems use parallel, closed center, control valves with special porting that allows the
highest work function pressure (LS signal) to feed back to the LS control.
Margin pressure is the difference between system pressure and the LS signal pressure. The LS control
monitors margin pressure to read system demand. A drop in margin pressure means the system needs
more flow. A rise in margin pressure tells the LS control to decrease flow.
LS control with bleed orifice (do not use with PVG valves)
The load sense signal line requires a bleed orifice to prevent high-pressure lockup of the pump control.
Most load-sensing control valves include this orifice. An optional internal bleed orifice is available, for use
with control valves that do not internally bleed the LS signal to tank.
Integral PC function
The LS control also performs as a PC control, decreasing pump flow when system pressure reaches the PC
setting. The pressure compensating function has priority over the load sensing function.
For additional system protection, install a relief valve in the pump outlet line.
Load sensing system characteristics:
17
Technical Information
Function
PC setting
Remote PC setting
Flow
Q max
Pressur e
P101 969E
P101 966
The remote PC control uses a pilot line connected to an external hydraulic valve. The external valve
changes pressure in the pilot line, causing the PC control to operate at a lower pressure. When the pilot
line is vented to reservoir, the pump maintains pressure at the load sense setting.
When pilot flow is blocked, the pump maintains pressure at the PC setting. An on-off solenoid valve can
be used in the pilot line to create a low-pressure standby mode. A proportional solenoid valve, coupled
with a microprocessor control, can produce an infinite range of operating pressures between the low
pressure standby setting and the PC setting.
Size the external valve and plumbing for a pilot flow of 3.8l/min [1US gal/min]. For additional system
protection, install a relief valve in the pump outlet line.
Remote pressure compensated system characteristics:
18
Technical Information
Function
PC setting
Flow
Q max
0
0
Pressur e
P101 166E
P101 965
Once the closed center valve is opened, the PC control senses the immediate drop in system pressure
and increases pump flow by increasing the swashplate angle.
The pump continues to increase flow until system pressure reaches the PC setting.
If system pressure exceeds the PC setting, the PC control reduces the swashplate angle to maintain
system pressure by reducing flow. The PC control continues to monitor system pressure and changes
swashplate angle to match the output flow with the work function pressure requirements.
If the demand for flow exceeds the capacity of the pump, the PC control directs the pump to maximum
displacement. In this condition, actual system pressure depends on the actuator load.
For additional system protection, install a relief valve in the pump outlet line.
C Caution
Do not use the PVG 32 with LB control.
Pressure compensated system characteristics
19
Technical Information
Function
PVPC adapter for external pilot oil supply
PVPC with check valve for open center PVP
PVPC with check valve is used in systems where it is necessary to operate the PVG 32 valve by means of
the electrical remote control without pump flow. When the external solenoid valve is opened, oil from
the pressure side of the cylinder is fed via the PVPC through the pressure reducing valve to act as the
pilot supply for the electrical actuators. This means that a load can be lowered by means of the remote
control lever without starting the pump.
The built-in check valve prevents the oil from flowing via the pressure adjustment spool to tank. With the
pump functioning normally the external solenoid valve is closed to ensure that the load is not lowered
due to the pilot supply oil flow requirement of approximately 1 l/min [0.25 US gal/min]. With closed
center PVP the external pilot oil supply can be connected to the pressure gauge connection without the
use of a PVPC plug.
PVPC with check valve for OC PVP
20
Technical Information
Function
Hydraulic diagram
21
Technical Information
Function
PVPC without check valve OC/CC PVP
Hydraulic diagram
22
Technical Information
Function
When the main pump flow fails, the external shuttle valve ensures that the oil flow from the manually
operated emergency pump is used to pilot open the over center valve and lower the load. The load can
only be lowered using the mechanical operating lever of the PVG 32 valve.
PVMR, friction detent
The friction detent PVMR allows the directional
spool to be held in any position, resulting in
infinitely variable, reversible, pressure
compensated flow.
P A F (Push-in)
P A F (Pull-out)
23
Technical Information
Function
The interaction between the small dead band of the spools and the hysteresis of the PVEM actuator of
20% involves a risk of building up a LS pressure in neutral position.
In a few systems load sensing pump pressure may result in unstable adjustment of the oil flow and a
tendency towards system hunting.
This may be the case with working functions that have a large moment of inertia or over-center valves. In
such systems main spools for pressure control can be advantageous.
PVBS, main spools for pressure control
The spools are designed in such a way that the pump pressure is controlled by the spool travel. The main
spool must be displaced until the pump pressure just exceeds the load pressure before the working
function is applied. If the main spool is held in this position, the pump pressure will remain constant
even if the load pressure changes giving a stable system.
The use of pressure control spools, however, also means that:
Due to these factors it is recommended that pressure control spools are only used when it is known for
certain that problems with stability will arise or already have arisen, and in applications where constant
pressure is needed e.g. drill holding.
Background
Instability in load sense control systems in certain applications with oscillations in the range of 1/2 - 2 Hz
can cause severe instability problems while trying to control functions in an application.
Critical applications are usually related to functions with an important inertia torque and/or functions
with secondarily fitted pressure controlled components e.g. over-center valves.
Examples:
a slewing function
main lifting/lowering function of a crane
The problem usually manifests itself in prolonged oscillation phenomena (Fig. 1), in a relatively constant
sequence of oscillations (Fig. 2) or in the worst case in an amplified sequence of oscillations (Fig. 3).
Fig. 1 Prolonged sequence
P
Prolonged sequence
time
Constant sequence
time
Amplified sequence
time
P005 627E
To control the oscillation phenomena the "pressure control spool" was developed and is a patented
system which can minimize most of the oscillation issues.
24
Technical Information
Function
Principle
The idea was to create a system operating independently of a constantly changing load pressure.
Therefore, we changed the well-known LS principle (Fig. 4), so that compensated pump pressure is part
of the LS system (Fig. 5) after the pressure compensator and before the metering range of the main spool.
Upon actuation of the spool, it will be led via a fixed and a variable orifice.
Fig. 4 Flow controlled spool
P005 625
P005 626
Application
Pressure controlled spools should in principle only be used when you have stability issues. Typical
applications on a crane:
Lifting/lowering movement
Slewing movement with cylinders
For the main lifting/lowering function on a crane it is recommended to fit a "half" pressure control
spool. This means that the spool is designed with a normal flow control on the lifting port and
pressure control connected to the port where the pilot signal to the over-center valve is acting. You
will thus maintain a load-independent lifting movement and achieve a stable but load-depending
lowering movement.
As the load pressure on slewing movements is usually steady - irrespective of the crane being loaded
or not it will be advantageous to use a "full" pressure control spool for A and B port.
In both cases we recommend the use of a basic valve, PVB, with pressure compensator. The pressure
compensator will ensure the individual load-independency between the basic valves.
It is further recommended to use the LS pressure relief valves as not only will they ensure individual
pressure limitation but also make it possible to adjust the maximum oil flow to the function.
25
Technical Information
Function
It is not recommended to use shock valves as pressure limiting valves in connection with pressure control
spools.
Sizing
The size of "half" (e.g: P - A = flow control P - B pressure control) pressure control spools is determined on
basis of max. flow demand on the lifting port. If e.g. a max. pressure compensated flow of 65 l/min for the
lifting movement, you choose a 65 L/min spool (size D). The metering characteristic has then a given size.
As it is often requested to limit the use of the crane boom for downward push/force mode and the LS
pressure limitation can be used. It will appear from the characteristics enclosed what effect a pressure
limitation, PLS will have on max. flow on the lowering port.
The size for a "full" pressure control spool is determined on basis of known load pressure, PLS max, and
requested max. flow.
It will appear from the characteristics enclosed that if the load PLS is low and the pump pressure, Pp, is
high as a result of max. stroked spool you will get a large flow.
If PLS is approaching PLS max. the flow will be reduced and the dead band increased. Max. oil flow can be
reduced by approx. 50% without limiting max. pressure.
The reduction is made by limiting the spool travel from 7 mm to 5.5 mm.
Limitation
If a pressure controlled spool is chosen for stability reasons consideration should be made to features
related to the pressure control principle.
Deadband will change according to the load conditions and the valve section will become loaddependent and that the pump pressure may exceed the load pressure.
With all of the above in mind, a pressure controlled spool will minimize oscillation and obtain a stable
function that can be controlled smooth and precise.
PVPX, electrical LS unloading valve
PVPX is a solenoid LS unloading valve. PVPX is fitted into the pump side module enabling a connection to
be made between the LS and the tank lines. Thus the LS signal can be relieved to tank by means of an
electric signal.
For a PVP pump side module in open center version the relief to tank of the LS signal means that the
pressure in the system is reduced to the sum of the tank port pressure plus the neutral flow pressure for
the pump side module.
For a PVP pump side module in closed center version the relief to tank of the LS signal means that the
pressure is reduced to the sum of the tank port pressure for the pump side module plus the stand-by
pressure of the pump.
PVPX, electrical LS unloading valve
26
Technical Information
The characteristics in this catalog are typical measured values. During measuring a mineral based
hydraulic oil with a viscosity of 21 mm2/s [102 SUS] at a temperature of 50 C [122 F] was used.
PVG 32 technical data
Max. pressure
Port P continuous1)
350 bar
[5075 psi]
Port P intermittent 5)
400 bar
[5800 psi]
350 bar
[5075 psi]
420 bar
[6090 psi]
Port T, static/dynamic
25/40 bar
[365/580 psi]
Port P3) 4)
140/230 l/min
[37/61 US gal/min]
100 l/min
[26.4 US gal/min]
125 l/min
[33 US gal/min]
7 mm
[ 0.28 in]
Proportional range
4.8 mm
0.19 in]
Float position
8 mm
[ 0.32 in]
Standard
1.5 mm
[ 0.06 in]
Linear characteristic
0.8 mm
[ 0.03 in]
20 cm3/min
[1.85 in3/min]
25 cm3/min
[2.15 in3/min]
Oil temperature
(inlet temperature)
Recommended temperature
30 60 C
[86 140F]
Min. temperature
-30 C
[-22 F]
+90 C
[194 F]
Ambient temperature
Max. temperature
-30 60 C
[-22 140 F]
Oil viscosity
Operating range
12 - 75 mm2/s
Min. viscosity
4 mm2/s
[39 SUS]
Max. viscosity
460 mm2/s
[2128 SUS]
Max. contamination
(ISO 4406)
23/19/16
23/19/16
5 l/min
[0.13 US gal/min]
Filtration
(See chapter Filtration)
Oil consumtion in pilot oil pressure reduction valve
1) With PVSI end plate. With PVS end plate max. 300 bar [4351 psi].
2) For 130 l/min contact Danfoss Product Application Engineering.
3) In open circuit systems with short P-hoses/tubes, attention should be paid to pressure peaks at flows
>100 l/min [26.4 US gal/min] .
4) For system with mid inlet PVPVM.
5) Intermittent pressure at max. 250,000 cycles of full PVG life time cycles, with PVSI end plate. The
maximum intermittent pressure at max. 250,000 cycles stresses the need to confirm application duty
cycle before proceeding with specification. For further information contact Danfoss Product Application
Engineering.
Rated Pressure
Product
27
Technical Information
PVM + PVE
PVM + PVH
PVM + PVMR
PVM+PVMF
2.2 0.2
[19.5 1.8]
2.2 0.2
[19.5 1.8]
2.5 0.2
[22.1 1.8]
17
[3.8]
22
[5.0]
2.8 0.2
[24.8 1.8]
2.8 0.2
[24.8 1.8]
6.9 0.2
[61.0 1.8]
60 [13.5]
28 [6.3]
8.5 [73.3]
No
2x6
Control range
control lever
19.5
proportional
13.4
float position
22.3
For PVE please see the PVE, Series 4 for PVG 32/100/120 Technical Information, 520L0553.
PVE technical data
Technical data for PVEO and PVEM
Supply voltage UDC
28
rated
12 VDC
24 VDC
range
11 V to 15 V
22 V to 30 V
max. ripple
5%
0.65 A @ 12 V
0.33 A @ 24 V
Technical Information
neutral
0.5 x UDC
A-port B-port
0.25 mA
12 K
Power consumption
8W
0.50 mA
Function
Disconnected by means of
neutral switch
Disconnected by means
of neutral switch
Constant voltage
Constant voltage
Hysteresis *
PVEO,
On/Off
PVEO-R,
On/Off
PVEM, Prop.
med.
max.
0.235 s
0.41 s
0.700 s
rated
0.180 s
0.35 s
0.450 s
min.
0.120 s
0.25 s
0.230 s
max.
0.175 s
0.33 s
0.175 s
rated
0.090 s
0.27 s
0.090 s
min.
0.065 s
0.25 s
0.065 s
max.
0.700 s
rated
0.450 s
min.
0.230 s
max.
0.700 s
rated
0.450 s
min.
0.230 s
rated
20%
* Hysteresis (control signal/spool travel) is indicated at rated voltage and f = 0.02 Hz for one cycle.
(one cycle = neutral full A full B neutral)
Technical data for PVEA, PVEH and PVES
PVEA, PVEH and PVES
Supply voltage UDC
rated
11 V to 32 V
range
11 V to 32 V
max. ripple
5%
PVEH/PVES (PVEA)
0.57 (33) A @ 12 V
Signal voltage
neutral
0.5 x UDC
A-port B-port
0.25 mA to 0.70 mA
12 K
Input capacitor
0.3 (17) A @ 24 V
100 F
Power consumption
PVEH/PVES (PVEA)
7 (3.5) W
(PVEH/PVES)
Max. load
100 mA
Active
Passive
60 mA
29
Technical Information
Function
Disconnected by means
of neutral switch
Disconnected by means
of neutral switch
Constant voltage
Constant voltage
Hysteresis *
PVEA
Prop. fine
s
PVEH
Prop. high
s
PVES
Prop. super
s
max.
0.50
0.23
0.23
rated
0.32
0.15
0.15
min.
0.25
0.12
0.12
max.
0.55
0.175
0.175
rated
0.40
0.09
0.09
min.
0.30
0.065
0.065
max.
0.50
0.20
0.20
rated
0.32
0.12
0.12
min.
0.25
0.05
0.05
max.
0.25
0.10
0.10
rated
0.20
0.09
0.09
min.
0.15
0.065
0.065
rated
2%
4%
0%
Typical hysteresis characteristics for control signal vs spool travel af different PVE types*
Spool position
* Hysteresis (control signal/spool travel) is indicated at rated voltage and f = 0.02 Hz. (one cycle = neutral
full A full B neutral)
The following technical data are from typical test results. For the hydraulic system a mineral based
hydraulic oil with a viscosity of 21 mm2/s [102 SUS] and a temperature of 50 C [122 F] were used.
Pilot oil consumption PVEA, PVEH, PVES, PVEO and PVEM
Function
PVEA
Prop. fine
PVEH
Prop. high
PVES
Prop. super
PVEO
ON/OFF
PVEM
Prop. medium
Neutral without
supply voltage
0.3 l/min
[0.079 US gal/min]
0.4 l/min
[0.106 US gal/min]
0.1 l/min
[0.026 US gal/min]
0.1 l/min
[0.026 US gal/min]
0.1 l/min
[0.026 US gal/min]
0.1 l/min
[0.026 US gal/min]
30
Technical Information
Pilot oil consumption PVEA, PVEH, PVES, PVEO and PVEM (continued)
Function
PVEA
Prop. fine
PVEH
Prop. high
PVES
Prop. super
PVEO
ON/OFF
PVEM
Prop. medium
0.7 l/min
[0.185 US gal/min]
0.8 l/min
[0.211 US gal/min]
0.7 l/min
[0.185 US gal/min]
0.5 l/min
[0.132 US gal/min]
Oil temperature
recommended range
12 - 75 mm2/s
minimum
4 mm2/s
[39 SUS]
maximum
460 mm2/s
[2128 SUS]
recommended range
30 - 60C
[86 -140F]
minimum
-30C
[-22F]
90C
[194F]
maximum
-30 60C
[-22 140F]
IP65
Oil temperature
(Inlet)
Recommended temperature
Min. temperature
-30C [-22F]
Max. temperature
90C [194F]
155C [311F]
Ambient temperature
Oil viscosity
Operating range
Min. viscosity
Max. viscosity
300 ms
Rated voltage
12 V
10%
1.55 A
0.78 A
0.5 A
Power consumption
1A
19 W
12 W
24 V
31
Technical Information
Electrical actuation
Electrical control of PVG
Valve actuation with electrical actuators has been supported by Danfoss for a long time. The actuation
can be controlled directly by joystick, by a PLUS+1 controller or by a broad range of third part
controllers. The actuator controls the spool by building up pilot oil pressure on the end of the spool. For
the PVE a pilot oil pressure between 10 and 15 bar is used. For the PVHC a pilot oil pressure between 20
and 25 bar is used.
PVG with PVE
Oil
B port
PVE
A port
PVB
PVM
Electronics
Neutral spring
NC Solenoid valves
NO solenoid valves
LVDT
PVBS
V310072.B
32
Technical Information
Electrical actuation
PVE characteristic - control by voltage
PVEP
control range
2.5V
5V
7.5V
PVEU
fixed
Hysteresis (Control signal /spool travel) is indicated at rated voltage and f = 0.02 Hz for one cycle (one
cycle = neutral full A full B neutral).
The values are typical test data for exact ranges, see PVE Technical Information, 520L0553.
33
Technical Information
Electrical actuation
The standard PVEs are proportional activated actuator except PVEO which is on/off.
The PVEs have fault-monitoring.
Fault monitoring overview
Type
Fault
monitoring
Error mode
LED light
Memory
(reset
needed)
PVEO
PVEM
No fault
monitoring
PVEA
PVEH
PVEP
PVES
PVEU
Active
500 ms
(PVEA: 750 ms)
No fault
Low
<2V
Green
High
UDC
Flashing red
Yes
Transducer (LVDT)
Constant red
250 ms
(PVEA: 750 ms)
No fault
Low
<2V
Green
High
~UDC
Flashing red
No
Transducer (LVDT)
Constant red
Active
500 ms
750 ms
High
~UD
Constant red
Power supply:
AMP version
12 V
24 V
Connectors:
AMP
DIN/Hirshmann
Deutsch
DIN/Hirschmann version
Deutsch version
PVEO/PVEO-R
U DC
U DC
157-502.11
34
Yes
Technical Information
Electrical actuation
PVEM
The PVEM is a proportional activated actuator. The PVEM has not fault-monitoring.
Variants:
Power supply: 12 / 24 V
Connectors:DIN/Hirshmann
PVEA, PVEH, PVES, PVEU
Variants:
Power supply: 11 32 V
Connectors:
AMP version
AMP
DIN/Hirshmann
Deutsch
DIN/Hirschmann version
Deutsch version
LED
PVEP
The PVEP is controlled with separate PWM control
signals for A and B direction.
Deutsch version
PVES-SP
LED
Not
connected
Error
Us
Spool position
3
2
1
4
5
6
UDC
35
Technical Information
Electrical actuation
PVED has digital communication, that allows a wide range of feedback, setpoint and highly costumized
settings. CAN bus serial communication makes wiring much easier. Only one cable per PVG group.
Power supply: 11 32 V PVE with Deutsch connector incl. female connector
Connectors:
Deutsch (PVED-CC)
AMP (PVED-CC and
PVED-CX)
For more information on PVED please see the PVED-CC, Series 4 Technical Information, 520L0665.
PVHC
For PVG controlled by PVHC, hysteresis is influenced by lever (PVM). The PVHC control is done by dual
Pulse Width Modulated (PVM) high current supply 100-400 Hz PWM control signals.
The PVHC does not have neither fault monitoring nor internal closed loop control of the spool.
Power supply:
12 V
24 V
44.4 [1.748]
5.7
[0.224]
Deutsch
AMP
26.75
[1.053]
26.75
[1.053]
74.0
[2.913]
74.0
[2.913]
16.5
[0.650]
5.75
[0.226]
P301 123
92.25
[3.631]
92.25
[3.631]
16.5
[0.650]
36
5.7
[0.224]
33.0 [1.299]
33.0 [1.299]
Connectors:
44.4 [1.748]
5.75
[0.226]
P301 124
Technical Information
Electrical actuation
PVHC characteristic - Spool stroke vs current
Spool stroke, mm
7
6
5
Ideal curve
4
3
Hysteresis
500/1000 mA
280/560 mA
280/560 mA
500/1000 mA
1600
@ 12V
800
1400
700
1200
600
1000
Current in mA
500
800
400
600
300
400
200
200
100
200
100
400
200
600
300
800
400
1000
500
1200
600
1400
700
800
1600
@ 24V
V310 000.A
PVHC current response and hysteresis @ 25 bar Pp, 21 ctS, 25 C. The ideal curve is determined by the
main spool neutral spring. The PVHC has high hysteresis. The hysteresis is affected by viscosity, friction,
flow forces, dither frequency and modulation frequency. The spool position will shift when conditions are
changed e.g. temperature change.
37
Technical Information
Technical characteristics
General
The characteristics in this catalog are typical measured values. During measuring a mineral based
hydraulic oil with a viscosity of 21 mm2/s [102 SUS] at a temperature of 50C [122F] was used.
PVP, pump side module
Pressure relief valve characteristic in PVP
The pressure relief valve is set at an oil flow of 15 l/min [4.0 US gal/min].
Setting range:
38
Technical Information
Technical characteristics
Linear oil flow depending on spool type
US = Signal voltage; UDC = Supply voltage; 1 = First PVB after PVP; 8 = Eighth PVB after
Pressure-compensated PVB, open or closed center PVP
The oil flow is dependent on the supplied pump oil flow. The characteristics are plotted for a pump oil
flow, QP, corresponding to the rated max. spool oil flow, QN. Increasing the pump oil flow to 1,4 QN will
give the same oil flow on the eighth as on the first basic module.
Please note, the letters AA, A, B, etc. denote spool types. The characteristic below is shown for spool
travel in both directions. All other characteristics are shown for spool travel in one direction only.
39
Technical Information
Technical characteristics
Progressive oil flow characteristic depending on spool type
PVM
PVM
PVE
PWM for PVEP/T
control range
157-61.im
US = Signal voltage; UDC = Supply voltage; 1 = First PVB after PVP; 8 = Eighth PVB after
PVB without pressure compensation, open center PVP
The spool flow is dependent on the supplied oil flow, QP.
The characteristics apply to supply oil flow of 130 l/min [34.3 US gal/min] with the actuation of one basic
module and the supply flow level.
If several basic modules are activated at the same time, the characteristic depends on the load pressure
of the actuated basic modules.
40
Technical Information
Technical characteristics
Oil flow as a function of spool travel characteristic
41
Technical Information
Technical characteristics
PVB without pressure compensation, closed center PVP
Set pressure difference between pump pressure and LS signal = 10 bar [145 psi].
Set pressure difference between pump pressure and LS signal = 20 bar [290 psi].
42
Technical Information
Technical characteristics
The oil flow is dependent on the pressure difference between the pump pressure and the LS signal.
Normally the pressure difference is set at the LS pump regulator. Also take into consideration pressure
drop from the pump to the PVG valve group. e.g. long pipeline.
Oil flow characteristics for PVB at
Load-independent, pressure-compensated
43
Technical Information
Technical characteristics
44
Technical Information
Technical characteristics
Pressure control spool flow characteristics
Size A:
Size B:
Example 1
Size C:
Size D:
Example 2
Size E:
Given:
Given:
45
Technical Information
Technical characteristics
Example 1: Determining the oil flow
Spool type B
Pressure setting PP: 160 bar [2320 psi]
Load pressure, LSA/B: 100 bar [1450 psi]
Result:
Result:
Normally a smaller spool can be chosen with pressure control. It is our experience that the spool can be
one size smaller than with normal flow control.
Characteristics for float position main spools
Characteristic of oil flow, spool travel and voltage
8 mm [0.19 in] spool displacement in direction A gives max. oil flow to port A
8 mm [0.19 in] spool displacement in direction B gives max. oil flow to port B
8 mm [0.32 in] spool displacement in direction B gives completely open float position A/B T.
The spools have 4,8 mm spool travel in direction A and 8 mm travel in direction B:
For more information regarding electrical actuation of float spools please see PVE series 4 Technical
Information, 520L0553.
46
Technical Information
Technical characteristics
Pressure drop A/B T at max. spool travel within the proportional range (4.8 mm) [0.19 in]
Spools D and E have the same opening area for forward flow and return flow.
Spool E can give 100 l/min [26.4 US gal/min] pressure compensated oil flow due to a higher pressure
drop across spool E. This occurs during spool actuation only.
Pressure drop A/B T in float position
47
Technical Information
Hydraulic systems
Manually actuated PVG 32 fixed displ. pump
Example schematic of manually actuated PVG 32 fixed displacement pump
48
Technical Information
Hydraulic systems
Electrically actuated PVG 32 variable displ. pump
Example schematic of electrically actuated PVG 32 variable displacement pump (electrical actuator, shock valves, relief valve)
49
Technical Information
complying with the demands on viscosity, water content, temperature and filtering etc. (see chapters
below and technical data).
adapting the operating conditions to the directions of the oil supplier.
Before using other biodegradable fluids, please consult the Danfoss organization. Oil filtration must
prevent particle content from exceeding an acceptable level, i.e., an acceptable degree of contamination.
Maximum contamination for PVG 32 is 23/19/16 (see ISO 4406. Calibration in accordance with the ACFTD
method). In our experience a degree of contamination of 23/19/16 can be maintained by using a filter
fineness as described in the next section.
For more information, please see the Danfoss literature:
Filtration
Effective filtration is the most important precondition in ensuring that a hydraulic system performs
reliably and has a long working life. Filter manufacturers issue instructions and recommendations. It is
advisable to follow these.
System filters
Where demands on safety and reliability are very high a pressure filter with bypass and indicator is
recommended. Experience shows that a 10 m nominal filter (or finer) or a 20 m absolute filter (or finer)
is suitable. It is our experience that a return filter is adequate in a purely mechanically operated valve
50
Technical Information
51
Technical Information
Dimensions
PVG 32 Dimensions
52
Technical Information
Dimensions
N: LS pressure limiting valve
O: Tank connection; G, 16 mm [1 1/16-12; 0.75 in] deep
P: Pressure relief valve
Q: Pump connection; G, 14 mm [7/8-14; 0.65 in] deep or G, 16 mm [1 1/16-12; 0.75 in] deep
R: LSA and LSB connections; G, 12 mm deep [9/16-18, 0.5 in] deep
S : Pp, pilot pressure connection G
PVB
L1
L2
10
11
12
mm
82
130
178
226
274
322
370
418
466
514
562
610
[in]
[3.23]
[5.12]
[7.01]
[8.90]
[10.79]
[12.68]
[14.57]
[16.46]
[18.35]
[20.24]
[562]
[610]
mm
140
189
238
287
336
385
434
483
527
576
622
670
in]
[5.51]
[7.44]
[9.37]
[11.30]
[13.23]
[15.16]
[17.09]
[19.02]
[20.95]
[22.87]
[622]
[670]
53
Technical Information
Dimensions
44 [
110[4.33]
max.200.5[7.894]
6.5
1.73
85[3.35]
33[1.30]
P
V
M
D
~1
65[
2]
6.5[0.256]
7[0.28]
49.5[1.949]
P
V
H
7[0.28]
32[1.26]
85[3.35]
58.5[2.303]
45[1.77]
P
V
M
R
/
F
0]
A-A
60[2.36]
17[0.67]
7[0.28]
129[5.08]
95[3.74]
13[0.51]
85.5[3.366]
B-B
PVEO
107[4.21]
110[4.33]
max.290.50[11.437]
60[2.36]
89.5[3.524]
117[4.61]
7[0.28]
139[5.472]
C-C
PVEM/PVEH/
PVES
107[4.21]
110[4.33]
max.290.50[11.437]
60[2.36]
V310141.A
54
Technical Information
Dimensions
PVM, control lever positions
Base with an angle of 37.5
19.
19.5
19
19
.5
.5
37.5
67
.5
.5
97
.5
127
22.5
52
.5
82
.5
11
172.5
187.5
142.5
2.5
157.5
V310018.A
V310014.A
The angle of the handle is determined by which side of the handle that is mount towards the base. If a
22.5 angle is needed the "dot" on the handle is not visible. If 37.5 is needed the dot should be visible.
Surface treatment
The PVG valve has as standard, an untreated surface. In certain applications, depend on different factors,
such as: salty environment, large temperature changes, high humidity, rust can develope on the surface.
This will not affect the performance of the PVG valve group. To prevent/reduce rust development,
Danfoss recommend the PVG valve group to be painted. Rust on the surface is not seen as a valid
complaint issue, neither on painted or unpainted PVG valve groups.
55
Technical Information
Description
Open center pump side module for pumps
with fixed displacement.
For purely mechanically actuated valve
groups
Code number
P=G
T=G
157B5000
P = 7/814
T = 1 1/1612
157B5200
P, T = G
157B5100
P, T = 1 1/1612
157B5300
P=G
T=G
157B5001
P = 7/814
T = 1 1/1612
157B5201
P, T = G
157B5101
P, T = 1 1/1612
157B5301
P=G
T=G
157B5010
P = 7/814
T = 1 1/1612
157B5210
P, T = G
157B5110
P, T = 1 1/1612
157B5310
P=G
T=G
157B5011
P = 7/814
T = 1 1/1612
157B5211
P, T = G
157B5111
P, T = 1 1/1612
157B5311
P=G
T=G
157B5012
P = 7/814
T = 1 1/1612
157B5212
P, T = G
157B5112
P, T = 1 1/1612
157B5312
P=G
T=G
157B5013
P = 7/814
T = 1 1/1612
157B5213
P, T = G
157B5113
P, T = 1 1/1612
157B5313
Connections:
P = G in; 14 mm deep or G in; 16 mm deep / LS, M = G in; 12 mm deep / T = G in; 16 mm deep.
P = 7/814; 0.65 in deep or 1 1/1612; 0.75 in deep / LS, M = 20; 0.47 in deep / T = 1 1/1612; 0.75 in
deep.
56
Technical Information
Description
Code number
P, T = G
157B5102
P, T = G
157B5103
P, T = G
157B5180
P, T = 1 1/1612
LS connection =
9/1618
157B5380
P, T = G
157B5181
P, T = 1 1/1612
LS connection =
9/1618
157B5381
P, T = G
157B5190
P, T = 1 1/1612
LS connection =
9/1618
157B5390
P, T = G
157B5191
P, T = 1 1/1612
LS connection =
9/1618
157B5391
Connections:
P, T = G in; 16 mm deep / LS, M = G in; 12 mm deep
P, T = 1 1/1612; 0.75 in deep / LS, M = 20; 0.47 in deep.
57
Technical Information
Description
No facilities for
shock valves A/B
G
14 mm deep
157B6000
157B6030
7/814
0.65 in deep
157B6400
157B6430
G
14 mm deep
157B6100
157B6130
7/814
0.65 in deep
157B6500
157B6530
G
14 mm deep
157B6136
7/814
0.65 in deep
157B6536
G
14 mm deep
157B6200
157B6230
7/814
0.65 in deep
157B6600
157B6630
G
14 mm deep
11071832
7/814
0.65 in deep
V310411.A
58
Code number
Technical Information
PVB, basic modules without adjustable LSA/B pressure limiting valves (continued)
Symbol
Description
Code number
No facilities for
shock valves A/B
G
14 mm deep
157B6206
157B6236
7/814
0.65 in deep
11036629
11036630
Description
Code number
No facilities for
shock valves A/B
Facilities for
shock valves A/B
With non-damped
compensator valve
Adjustable LSA/B pressure
limiting valves
External LS connection port
A/B.
Also used for float position
spools
G
14 mm
deep
157B6203
157B6233
7/814
0.65 in
deep
157B6603
157B6633
G
14 mm
deep
157B6208
157B6238
7/814
0.65 in
deep
11036631
2032
2050
2063
2080
2100
2125
2140
2150
2160
2175
2190
bar
32
50
63
80
100
125
140
150
160
175
190
psi
460
725
914
1160
1450
1813
2031
2175
2320
2538
2755
59
Technical Information
Description
Shock and suction valve for port A and/or B.
(Not adjustable).
Lifetime 200.000 actuations.
Description
Code
number
157B2001
157B2002
60
Description
Code number
with stop screws w/o stop screws
157B3171
157B3191
157B3173
157B3193
157B3174
157B3194
157B3184
Technical Information
Description
Material
Code No.
Anodized
aluminium
157B0001
no
aluminium
157B0009
yes
cast iron
157B0021
no
Description
Material
Code number
Anodized
aluminium
157B0004
no
aluminium
157B0012
yes
cast iron
157B0024
Description
Material
Code number
Anodized
PVMF,
Mechanical float position lock
aluminium
157B0005
no
Description
Material
Code number
Anodized
aluminium
157B0007
no
aluminium
157B0010
yes
cast iron
157B0014
no
aluminium
157B0008
no
aluminium
157B0011
yes
cast iron
157B0016
no
Description
Mounting
threads
Code number
BSP
157B2000
SAE
157B2020
G 1/8 10 mm deep
BSP
157B2011
SAE
157B2021
V310062.A
LX
V310063.A
61
Technical Information
Description
Mounting
threads
Code number
BSP
157B2014
SAE
157B2004
G 1/4 10 mm deep
BSP
157B2015
SAE
157B2005
V310062.A
LX
V310063.A
10
11
12
PVBs
8000
8001
8002
8003
8004
8005
8006
8007
8008
8009
8010
8061
8062
PVB + PVPVM -
8021
8022
8023
8024
8025
8026
8027
8028
8029
8030
8081
8082
0.15
[0.3]
0.25
[0.6]
0.30
[0.7]
0.40
[0.9]
0.45
[1.0]
0.50
[1.1]
0.60
[1.3]
0.65
[1.4]
0.70
[1.6]
0.80
[1.7]
0.85
[1.8]
0.9 [2.0]
Description
Code number
12 V
157B4236
24 V
157B4238
12 V
157B4246
24 V
157B4248
12 V
157B4256
24 V
157B4258
Plug
157B5601
Description
PVP,
Plug without check valve for open
or closed center
62
Code number
G 1/2,
12 mm deep
157B5400
1/2 in - 20;
0.47 in deep
Technical Information
Description
PVP,
Plug with check valve for
open center
Code number
G 1/2,
12 mm deep
157B5600
1/2 in - 20;
0.47 in deep
157B5700
63
Technical Information
ISO symbol
Symbol
F
E
D
C
B
130
100
65
40
25
[34.3] [26.4] [17.2] [10.6] [6.6]
A
10
[2.6]
AA
5 [1.3]
AA
A
5 [1.3] 10
[2.6]
B
25
[6.6]
C
D
E
F
40
65
100
130
[10.6] [17.2] [26.4] [34.3]
7026
7020
7025
7005
7000
7001
7002
7003
7004
7006
7105
7100
7101
7102
7103
7104
7106
7200
7201
7202
7203
7204
7301
7302
7303
7304
7401
7402
7403
7404
7406
7501
7502
7503
7504
7024
7023
7022
7021
4-way, 3-position
Closed neutral position
7126
7124
7123
7122
7121
7120
7125
4-way, 3-position
Throttled, open neutral position
-
3-way, 3-position
Closed neutral position, P A
-
3-way, 3-position
Closed neutral position, P B
-
7424
7423
7422
7421
4-way, 3-position
Throttled, A T in neutral position
-
7524
7523
7522
7521
4-way, 3-position
Throttled, B T in neutral position
-
7624
7623
7622
7621
7620
157-139.10
157-140.10
4-way, 4-position
Closed neutral position
Float P B F
64
Technical Information
ISO symbol
E
100
[26.4]
D
65
[17.2]
C
40
[10.6]
B
25
[6.6]
A
10
[2.6]
AA
5
[1.3]
AA
5
[1.3]
A
10
[2.6]
B
25
[6.6]
C
40
[10.6]
D
65
[17.2]
E
100
[26.4]
9024
9023
9022
9021
9020
9025
9005
9000
9001
9002
9003
9004
9105
9100
9101
9102
9103
9104
4-way, 3-position
closed neutral position
9124
9123
9122
9121
9120
9125
4-way, 3-position
Throttled open neutral position
ISO symbol
Symbol
F
E
D
C
B
130
100
65
40
25
[34.3] [26.4] [17.2] [10.6] [6.6]
A
10
[2.6]
AA
5
[1.3]
AA
5
[1.3]
A
10
[2.6]
B
25
[6.6]
C
D
E
F
40
65
100
130
[10.6] [17.2] [26.4] [34.3]
9820
9825
9824
9823
9822
9821
4-way, 4 position
Closed neutral position
PAF
-
9624
623
9622
9621
157-140.10
157-139.10
4-way, 4-position
Closed neutral position
Float P B F
D
65
[17.2]
C
40
[10.6]
B
25
[6.6]
A
10
[2.6]
ISO symbol
AA
5
[1.3]
A
10
[2.6]
B
25
[6.6]
C
40
[10.6]
D
65
[17.2]
E
100
[26.4]
65
Technical Information
9723
9722
9721
9700
9701
9702
9703
9704
9710
9711
9712
9713
9714
4-way, 3-position
closed neutral position
9734
9733
9732
9731
9730
4-way, 3-position
Throttled open neutral position
ISO symbol
Symbol
F
E
D
C
B
130
100
65
40
25
[34.3] [26.4] [17.2] [10.6] [6.6]
A
10
[2.6]
AA
5
[1.3]
AA
5
[1.3]
A
10
[2.6]
B
25
[6.6]
C
D
E
F
40
65
100
130
[10.6] [17.2] [26.4] [34.3]
9750
9751
9752
9753
9754
9760
9761
9762
9763
9764
9794
9804
9774
9773
9772
9771
4-way, 3-position
Closed neutral position
-
9784
9783
9782
9781
4-way, 3-position
Throttled, open neutral position
-
4-way, 3-position
Throttled, A T in neutral position
-
4-way, 3-position
B T in neutral position
66
Technical Information
ISO symbol
E
100
[26.4]
D
65
[17.2]
C
40
[10.6]
B
25
[6.6]
A
10
[2.6]
AA
5
[1.3]
AA
5
[1.3]
A
10
[2.6]
B
25
[6.6]
C
40
[10.6]
D
65
[17.2]
E
100
[26.4]
7033
7032
7031
7030
7035
7015
7010
7011
7012
7013
7115
7110
7111
7112
7113
7040
7041
7042
7043
7044
7050
7051
7052
7053
7054
7150
7151
7152
7153
7154
7150
7151
7152
7153
7154
7452
7453
4-way, 3-position
Closed neutral position, PC A and B
7134
7133
7132
7131
7130
7135
7063
7062
7061
4-way, 3-position
Closed neutral position, PC A
7074
7073
7072
7071
4-way, 3-position
Closed neutral position, PC B
7164
7163
7162
7161
4-way, 3-position
Throttled, open neutral position, PC A
7174
7173
7172
7171
4-way, 3-position
Throttled, open neutral position, PC B
-
7473
7472
7471
7470
4-way, 3-position
Throttled, A T neutral position, PC B
67
Technical Information
7563
7562
7541
7542
7543
4-way, 3-position
Throttled, B T neutral position , PC A
ISO symbol
E
100
[26.4]
D
65
[17.2]
C
40
[10.6]
B
25
[6.6]
A
10
[2.6]
AA
5
[1.3]
AA
5
[1.3]
A
10
[2.6]
B
25
[6.6]
C
40
[10.6]
D
65
[17.2]
E
100
[26.4]
9015
9010
9011
9012
9042
9043
9044
9052
9053
9054
4-way, 3-position
Closed neutral position, PC A and B
-
4-way, 3-position
Closed neutral position, PC A
-
4-way, 3-position
Closed neutral position, PC B
68
Technical Information
0
0
1-13
16
14
a
15
V310168.A
78 - 14 UNF
78 - 14 UNF
157B6000
157B6400
157B6030
157B6430
157B6100
157B6500
157B6130
157B6530
157B6136
157B6536
157B6200
157B6600
157B6230
157B6630
69
Technical Information
78 - 14 UNF
78 - 14 UNF
157B6206
157B6236
157B6203
157B6603
157B6233
157B6633
157B6208
157B6238
Weight
3.1 [6.8]
kg [lb]
3.0 [6.6]
PVPC, plugs
Description
in - 20
Weight
kg
[lb]
157B5400
0.05
0.1
157B5600
157B5700
0.05
0.1
Alu
Alu anodized
Cast iron
Angle
without stop
screws
157B3171
157B3191
157B3184
157B3161
22,5/37,5
157B3194
22,5/37,5
157B3173
157B3193
157B3186
Weight kg [lb]
0.4 [0.9]
Standard
0.8 [1.8]
10
11
12
PVBs
8000
8001
8002
8003
8004
8005
8006
8007
8008
8009
8010
8061
8062
PVB +
PVPVM
8021
8022
8023
8024
8025
8026
17B8027 8028
8029
8030
8081
8082
Weight
kg [lb]
0.1 [0.2]
0.15 [0.3] 0.25 [0.6] 0.30 [0.7] 0.40 [0.9] 0.45 [1.0] 0.50 [1.1] 0.60 [1.3] 0.65 [1.4] 0.70 [1.6] 0.80 [1.7] 0.85 [1.8] 0.9 [2.0]
Open
center
70
for PVE
P = G1/2, T = G3/4
157B5000
157B5010
157B5012
157B5200
157B5210
157B5212
Technical Information
157B5100
157B5102
157B5110
157B5112
157B5180
157B5190
157B5310
157B5312
157B5380
157B5390
P = G1/2 , T = G3/4,
157B5001
157B5011
157B5013
157B5201
157B5211
157B5213
P = G3/4, T = G3/4,
157B5101
157B5103
157B5111
157B5113
157B5181
157B5191
157B5311
157B5313
157B5381
157B5391
P = G3/4, T = G3/4
Closed
center
kg [lb]
3 [6.6]
Code No.
AMP
Weight
kg [lb]
12 V
157B4236
157B4981
0.3 [0.7]
24 V
157B4238
157B4982
12 V
157B4246
157B4983
24 V
157B4248
157B4984
12 V
157B4256
157B4985
24 V
157B4258
157B4986
Plug
157B5601
0.06 [.13]
BSP
SAE
Weight
kg [lb]
157B2000
157B2020
0.5 [1.1]
157B2011
157B2021
157B2014
157B2004
157B2015
157B2005
1.7 [3.6]
157B203
2
157B205
0
157B206
3
157B208
0
157B210
0
157B212
5
157B214
0
157B215
0
157B216
0
157B217
5
157B219
0
bar
32
50
63
80
100
125
140
150
160
175
190
psi
460
725
914
1160
1450
1813
2031
2175
2320
2538
2755
157B221
0
157B223
0
157B224
0
157B225
0
157B226
5
157B228
0
157B230
0
157B232
0
157B235
0
157B238
0
157B240
0
bar
210
230
240
250
265
280
300
320
350
380
400
psi
3045
3335
3480
3625
3845
4061
4351
4641
5075
5511
5801
Code no.
Settings
71
Technical Information
Code No.
Hirsch
AMP
Deut.
12 V
157B4216
157B4901
157B4291
24 V
157B4228
157B4902
157B4292
12 V
157B4217
157B4903
24 V
157B4229
157B4904
12 V
157B4116
24 V
157B4128
12 V
157B4416
24 V
157B4428
157B4734
157B4735
157B4792
-
157B4736
157B4737
157B4796
-
157B4032
157B4033
157B4034
157B4035
157B4092
157B4093
157B4332
-
157B4338
157B4392
-
157B4036
157B4037
157B4096
-
157B4832
157B4833
157B4834
157B4835
157B4892
-
PVEO, on-off
PVEO-R, on/off
Weight
kg [lb]
0.6 [1.3]
0.9 [2.0]
1.0 [2.2]
0.9 [2.0]
1.0 [2.2]
Code No.
Material
Anodized
Weight
kg [lb]
PVMD
Cover for PVB
PVMR
(Friction Detent)
157B0001
aluminium
157B0009
157B0021
cast iron
N/A
0.9 [2.0]
157B0004
aluminium
no
0.3 [0.6]
157B0012
yes
cast iron
N/A
157B0005
aluminium
no
aluminium
no
157B0010
Hydraulic actuation PVH G1/4
157B0014
cast iron
N/A
157B0008
aluminium
no
157B0016
0.2 [0.4]
yes
157B0011
0.1 [0.2]
yes
157B0024
PVMF
(Mech. float position)
72
no
yes
cast iron
N/A
0.9 [2.0]
Technical Information
Code No.
Weight
kg
[lb]
Plug A or B
157B2002
0.04
0.09
Valve A or B
157B2001
0.05
0.1
73
Technical Information
Order specification
An order form for PVG 32 hydraulic valve is shown on the next page.
The form can be obtained from the Danfoss Sales Organization.
Both the module selection chart on the previous pages and the order form are divided into fields 0,
1-1-12, 13, 14, 15, a, b, and c.
Each module has its own field:
0:
b:
74
Technical Information
Order specification
The figures in the table have been calculated according to the following expressions:
Max. pressure setting of LSA and LSB valves relative to PVLP shock valve
Pressure
setting
for PVLP
bar 32
50
63
80
100
125
140
150
160
175
190
210
230
240
250
265
280
300
320
350
380
400
psi
72
5
91
4
11
60
145
0
181
3
203
1
217
5
232
0
283
8
275
5
304
5
333
5
348
0
362
5
384
3
406
1
435
1
464
1
507
5
551
1
580
1
40
50
64
80
100
112
120
130
145
160
180
200
210
220
235
250
270
290
320
350
370
58
0
72
0
93
0
116
0
145
0
162
5
174
0
188
5
210
0
232
0
261
0
290
0
304
5
319
0
340
8
362
5
391
5
420
5
464
1
507
5
536
6
46
0
75
Technical Information
Order specification
PVG 32 order specification form
Separate specification pads are available under the literature no. 520L0515.
76
Technical Information
77
Technical Information
78
Technical Information
79
Products we oer:
Danfoss Power Solutions is a global manufacturer and supplier of high-quality hydraulic and
electronic components. We specialize in providing state-of-the-art technology and solutions that
excel in the harsh operating conditions of the mobile o-highway market. Building on our extensive
applications expertise, we work closely with our customers to ensure exceptional performance for a
broad range of o-highway vehicles.
Displays
Electrohydraulic Power
We help OEMs around the world speed up system development, reduce costs and bring vehicles to
market faster.
Danfoss Your Strongest Partner in Mobile Hydraulics.
Steering
Electrohydraulics
Integrated Systems
We oer expert worldwide support for our customers, ensuring the best possible solutions for
outstanding performance. And with an extensive network of Global Service Partners, we also provide
comprehensive global service for all of our components.
Microcontrollers and
Software
Orbital Motors
PLUS+1 GUIDE
Proportional Valves
Sensors
Steering
Transit Mixer Drives
Comatrol
www.comatrol.com
Schwarzmller-Inverter
www.schwarzmuellerinverter.com
Local address:
Turolla
www.turollaocg.com
Valmova
www.valmova.com
Hydro-Gear
www.hydro-gear.com
Daikin-Sauer-Danfoss
www.daikin-sauer-danfoss.com
Danfoss
Power Solutions US Company
2800 East 13th Street
Ames, IA 50010, USA
Phone: +1 515 239 6000
Danfoss
Power Solutions GmbH & Co. OHG
Krokamp 35
D-24539 Neumnster, Germany
Phone: +49 4321 871 0
Danfoss
Power Solutions ApS
Nordborgvej 81
DK-6430 Nordborg, Denmark
Phone: +45 7488 2222
Danfoss
Power Solutions
(Shanghai) Co. Ltd.
Building #22, No. 1000 Jin Hai Rd
Jin Qiao, Pudong New District
Shanghai, China 201206
Phone: +86 21 3418 5200
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to
products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
www.danfoss.com