P80PB
P80PB
P80PB
Standby Model:P88E/B
Rating Range
3P4W
QUALITY STANDARDS
The SUPERWATT generator set compliance with all main
standards, such as ISO8528 GB/T2820-97), GB755
BS5000, VDE0530, ISO3046, IEC34-1, CSA22-2, AS1359,
ISO14001.
1500RPM 50Hz
Standby:
kW
k VA
70.4
88
Prime:
kW
k VA
64
80
WARRANTY
ALTERNATOR RATINGS
Alternator Model
UCI224G(STAMFORD)
50Hz
1500rpm
50Hz
1500rpm
Cont.H -125K/40
Cont.H -125K/40
380
400
415
440
380
400
415
440
190
200
208
220
190
200
208
220
220
230
240
254
220
230
240
N/A
Rating capacity(kVA)
85.0
85.0
85.0
75.0
78.0
80.0
80.0
76.0
Rating power(kW)
68.0
68.0
68.0
60.0
62.0
64.0
63.0
61.0
Power efficiency(%)
89.8
90.2
90.4
90.8
90.5
90.5
90.5
90.5
Input power(kW)
75.7
75.4
75.2
69.6
68.5
70.7
69.6
67.4
Standby.H -125K/40
Standby.H -150K/40
380
400
415
440
380
400
415
190
200
208
220
190
200
208
220
220
230
240
254
220
230
240
N/A
Rating capacity(kVA)
87.5
87.5
87.5
76.9
83.0
84.0
83.0
83.0
Rating power(kW)
70.0
70.0
70.0
61.5
66.0
67.0
66.0
66.0
Power efficiency(%)
89.7
90.1
90.3
90.7
90.1
90.1
90.1
90.1
Input power(kW)
78.0
77.7
77.5
71.4
73.3
74.4
73.3
73.3
440
RATINGS: All three-phase units are rated at 0.8 power factor. Standby ratings : Standby
ratings apply to installations served by a reliable utility source. The standby rating is for
this rating. Ratings are in according with ISO-3046/1,BS 5514 ,AS 2789 , and DIN 6271.
Prime Power Ratings: Prime power ratings apply to installations where utility power is
unavailable or unreliable. At varying load, the number of generator set operating hours
is unlimited. A 10% overload capacity is available for one hour in twelve. Ratings are in
accordance with IS0-8528/1, overload capacity in accordance with ISO-3046/1,BS 5514,
AS 2789, and DIN 6271. For limited running time and base load ratings, consult the
factory. The generator set manufacturer reserves the right to change the design or
specifications without notice and without any obligation or liability whatsoever.
GENERAL GUIDELINES FOR DERATION: Altitude: Derate 2.0% per 300m(984 ft.)
elevation above 1000m(3279 ft.) up to a maximum elevation of 2450m(8000 ft.).More than
2450m(8000ft), please contacts with us or our dealer seek the help.
Temperature: Derate 6.0% per 11
(20
) temperature above 40 (104
).
ALTERNATOR
1500RPM 50Hz
Specification
Stator winding
Winding pitch
Winding leads
Maximum overspeed
Altitude
1.5%
Class H
IP23
The 2/3 pitch design avoids excessive neutral currents. With the
2/3 pitch and carefully selected pole and tooth designs,
ensuresvery low waveform distortion.
0.8
Double layer concentric
Two thirds
12
2250 Rev/min
Self excited machines do not
sustain a short circuit current
Type
Exciter type
Voltage regulator
Voltage regulation
Insulation
Protection
Rated power factor
DIESEL ENGINE
1104A-44TG2 diesel engines are manufactured by Perkins
Engines Company Limited(UK).
Engine Electrical
1500RPM 50Hz
Negative
12V
60A
12V
3KW
Cylinder arrangement
4
Vertical in-line
105 rev/min
Cycle
Four stroke
Battery voltage
12V
Induction system
Turbocharged
Fuel
Compression ratio
Bore
17.25:1
105 mm (4.13 in)
Fuel System
1500RPM 50Hz
Type of injection
Fuel injection pump
Fuel injector
Nozzle opening pressure
Direct
Rotary type
Multi-hole
29.0Mpa(4208lbf/in 2 )
1500RPM 50Hz
Electrical
63litres/hr(16.6UK gals/hr)
Application Data
1500RPM 50Hz
EngineSpecifications
PERKINS
Manufacturer
Number of cylinders
Stroke
Cubic capacity
Direction of rotation
Firing order
1, 3,4,2
80.7kW
463kg (1019 lb)
0.75%
Fixed
Dry
6.35 m/s(20.8ft/s)
5.14 m3 /min(181.5ft 3 /min)
Pressure
Maximum suction head
Governor type
Fuel specification
Density (kg/l @ 15
Exhaust
30-75kPa(4.35-10.875 lbf/in 2 )
25kPa(3.625lbf/in 2 )
Electronic governor
)
1500RPM 50Hz
Viscosity (mm2/s @ 40
Sulphur Content
Cetane Number
580
Exhaust System
Total system
Minimum
Relief valve opens
Normal oil temperature
2.5 - 3.5
0.1%-0.2%
45 minimum
Fuel consumption
1500RPM 50Hz
Power rating %
Lubrication
Lubrication system
0.835 - 0.845
)
1500RPM
50Hz
Litres/hr(UK gals/hr)
110
100
20.5 (4.5)
18.7 (4.1)
75
14.0 (3.0)
50
25
9.7(2.1)
5.2(1.1)
Application Data
Cooling System
Radiator
1500RPM 50Hz
Face area
Rows and materials
0.276 m 2 (2.97 ft 2 )
Double row aluminium
Width of matrix
Height of matrix
Fan
1500RPM 50Hz
Diameter
Drive ratio
Number of blades
Material
Type
Coolant
1500RPM 50Hz
110
(230 )
Protection:
TBA
TBA
( )
( )
TBAkPa( lbf/in2 )
Thermostat operation range
75 - 87 (167 - 189 )
Recommended coolant:
50% ethylene glycol with a corrosion inhibitor
(BS 6580 :1992 or ASTM D3306-89 or AS2108)
and 50% clean fresh water.
CONTROLLERS
(Optional)
Panel introduction:
Indicator or digital type frequency, voltmeter and ampere meter
demonstration unit's electrical parameter.
The big red button uses for the operator to stop the genset
peremptorily
The controller.
Panel introduction:
Indicator type frequency, voltmeter and ampere meter
demonstration unit's electrical parameter.
The voltage change-over switch and the rheotrope uses for to
choose the different phase voltage and current to display.
The big red button uses for the operator to stop the genset
peremptorily
The oil pressure gauge, coolant temperature gauge and the
battery voltage gauge.
The controller. And an integral anti-tamper LCD hours run
counter is also provided.
If the customer needs to use the preheating function, we will be
able to increase the preheating button.
Protection:
Low Oil Pressure
High Engine Temperature
Auxiliary Shutdown
Over speed
Function:
Communication: RS232 connection, uses the industry rank
MODBUS protocol can easily communicate with others
intelligence control system.
Display function: LCD screen can display the generator's
parameter and the control system's running information.
Set up parameter: Engineer can set up the controller parameter
from the control panel or through the PC, 6 programmable
fan-out may satisfy the user each kind of demand.
Protection: The control system can protect the generator set ,
manage each kind of electrical failure.
Control Function of ATS.
DC Supply: 8 to 35 V Continuous.
NOTE: More functions or please refer to website www.genset.cn. Extra demand
please contacts our sales engineer.
DC Supply: 8 to 35 V Continuous.
Paralleling System
Controller System
Accessories
Enclosed Unit
Miscellaneous Accessories
Sound Enclosure
Weather Enclosure (with enclosed critical silencer)
Weather Housing (with roof-mounted critical silencer)
Trailer(Causes the genset easily to move)
Open Unit
Exhaust Silencer, Critical kit
Open Style
Cooling System
Block Heater
(recommended for ambient temperatures below 0
Overall Size, L W H
)
mm
2240 730
Weight(radiator model),net,Kg
1470
1080
Fuel System
Auxiliary Fuel Pump
Soundproof Style
Overall Size, L W H
Weight(radiator model),net,Kg
mm
Electrical System
Battery Charger, Equalize/Float Type
NOTE : This drawing is provided for reference only and should not be used for planning
installation. Contact your local distributor for more detailed information.