Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Abb Fox System Specifications r8 RF 1khw002006

Download as pdf or txt
Download as pdf or txt
You are on page 1of 68

ABB Power Systems

FOX515
FOX System Specification
User Manual

User Guide FOX515 System Specification (R8)

User Guide
FOX515 System Specification
Platform FOX515 Release R8

Release History:

Release 7B:
Release 8B:
Release 8C:

February 2007
Dezember 2008
August 2009
Dezember 2009
May 2010

Copyright and Confidentiality: All rights of this document remain with


ABB Ltd (ABB). This document contains confidential information which is
the property of ABB. It must be held in confidence by the recipient and
may not be used for any purposes except those specifically authorised by
contract or otherwise in writing by ABB. This document may not be
copied in whole or in part, or any of its contents disclosed by the recipient
to any third party, without the prior written agreement of ABB.

Disclaimer:

ABB has taken reasonable care in compiling this document, however


ABB accepts no liability whatsoever for any error or omission in the
information contained herein and gives no other warranty or undertaking
as to its accuracy.
ABB reserves the right to amend this document at any time without prior
notice.

Document number:

1KHW002006

ABB Ltd
Power Systems
Bruggerstrasse 72
5400 Baden Switzerland
ABB Switzerland Ltd, 2010
The right to modifications or deviations due to technical progress is reserved.

1KHW002006

page 2 of 68

ABB

User Guide FOX515 System Specification (R8)

Table of contents
1

Common features system specification

General

ABB

9
9

Traffic functions
ATM traffic
IMA
CES
PDH traffic
SDH traffic
Ethernet over SDH Ethernet switching
Ethernet over SDH
Ethernet switching
Ethernet LAN to TDM WAN bridging
Power over Ethernet provisioning (PoE)
V5 functions
NGN Access Gateway
ADSL and SHDSL based broadband access aggregation
Conference functions
Protection
Monitoring of traffic signals
Diagnostic functions

11
11
11
12
12
13
14
15
15
16
16
17
17
18
20
21
21
22

Synchronisation
General
PETS
SETS
Maintenance and Diagnostics
Fault management
SSM and QL processing

23
23
23
23
25
25
26

System control and management functions


Control system
NE software system
Management functions

27
27
27
28

Performance control and diagnostic functions


System level
Functional level
Central diagnostics

29
29
29
29

Compatibility with other FOX equipment

30

Architecture
System
ABUS

31
31
32

page 3 of 68

1KHW002006

User Guide FOX515 System Specification (R8)

SBUS
PBUS
UBUS

32
32
32

Management communication
Element Manager
Management communication structures
Routing functions

34
34
34
35

Cross connections and delays


PBUS cross connect
Traffic signal delays PBUS and UBUS
Traffic signal delays SBUS and PBUS
ATM cell delays
Traffic delay CES

37
37
37
37
38
38

Protection switching restoration times


SNCP
MSP
IMA
N+1 equipment protection

39
39
39
39
39

Interfaces
Traffic interfaces
Synchronisation interfaces
Management interfaces
Alarm interfaces
Power interfaces

41
41
41
42
43
44

EMC/ESD and safety


EMC
ESD
Safety

45
45
45
45

Ambient and dependability


Ambient conditions
Dependability

46
46
47

2
FOX515 (subrack R2) supplementary
specifications

1KHW002006

49

Powering
DC interface
Internal power supply
Power dissipation

49
49
49
50

Subracks
FOX515
FANU5 fan unit
DUPI4 dual supply input

51
49
51
53

Dimensions and weight


Dimensions
Weight

55
55
55

page 4 of 68

ABB

User Guide FOX515 System Specification (R8)

Installation
Subrack, cable tray
Connection of signals
Connection of power supply

56
56
56
56

3
FOX512 (subrack R2) supplementary
specifications

ABB

59

Powering
DC interface
AC interface
DC battery backup interface
Power consumption
Internal power supply
Power dissipation

59
59
59
60
60
60
61

Subracks
FOX512
FANU2 (R2) fan unit
BATMO battery package

62
60
62
64

Dimensions and weight


Dimensions
Weight

65
65
65

Installation
Subrack, cable tray
BATMO battery package
Connection of signals
Connection of power supply

66
66
66
66
67

page 5 of 68

1KHW002006

User Guide FOX515 System Specification (R8)

Precautions and safety


For generic information on precautions and safety refer to the precautions and safety user guide.

Referenced documents

1KHW002006

1KHW002000

Precautions and safety User Guide

1KHW002070

Release Note FOX / UCST

page 6 of 68

ABB

User Guide FOX515 System Specification (R8)

Technical support
ABB Technical Support is available as follows:

ABB Switzerland Ltd


Power Systems
Utility Communications
Bruggerstrasse 72
5400 Baden
Switzerland

ABB

Phone:

+41 58 589 37 35

or:

+41 844 845 845 (Call Center)

Fax:

+41 58 585 16 82

E-Mail:

utility.communication@ch.abb.com

URL:

www.abb.com/utilitycommunications

page 7 of 68

1KHW002006

User Guide FOX515 System Specification (R8)

1KHW002006

page 8 of 68

ABB

User Guide FOX515 System Specification (R8)

Common features system specification

Common features system


specification

General
System application
- Multiservice access

- Traffic signal types

- Access multiplexing
- Multiplexing/demultiplexing

data and voice


PDH traffic
SDH traffic
VC-12, VC-3, VC-4
CAS

- Special traffic processing


- V5.x

- NGN Access Gateway

- Broadband Access Aggregation

V5.1, V5.2
protocol and user ports
H.248 / RTP (POTS)
SIGTRAN (ISDN-BA)
H.248 / MEGACO
(Set up / release control)
ADSL, ADSL2(+) line IF
SHDSL, SHDSL.bis line IF
ATM Ethernet IWF
Voice over IP
Broadband
- video multicast
- IP services
Gbit-Ethernet uplinks
P0-nc (n = 1 ... 31)
P12s / P12x (structured and
unstructured)
STM-1
STM-4
P12x and P0-nc
DXC 1/1 and 1/0
VC-4, VC-3, VC-12
ATM cells
IP packets
MAC frames
PoE class 1 3
and manual power set

- Bit-rates of traffic signals

ABB

- Cross connecting

- Routing
Bridging
- Power provisioning over Ethernet (PoE)

:
:
:

page 9 of 68

data and voice services


local and remote interfaces
PDH traffic
SDH traffic
ATM traffic
IP traffic

1KHW002006

Common features system specification

1KHW002006

User Guide FOX515 System Specification (R8)

- Transmission

- Any mixture of above

Commissioning
- Traffic interfaces

- Traffic functions
- Functions

:
:

page 10 of 68

P0-nc (n = 1 ... 31)


P12
O22
E31/32
STM-1 (SDH)
(optical and electrical)
STM-4 (SDH)
(optical)
ATM cells
STM-1 (ATM)
(optical)
10BASE-T
100BASE-TX / FX
1000BASE-T / LX / SX
up to subrack and system
capacity
modular hardware
and software
core and modular functions
unit hardware and software

ABB

User Guide FOX515 System Specification (R8)

Common features system specification

Traffic functions
ATM traffic
ATM traffic signals
- Cell format
- Service categories

:
:

UNI
CBR-rt (CBR.1)
CBR-nrt (CBR.1)
VBR-nrt (VBR.1)
UBR

ATM traffic functions


- Termination

- Services

VC-4 / ATM cells


IMA according to
AF-PHY-0088.001 V1.1
CES 2 Mbit/s (AAL1)
according to
AF-VTOA-0078.00 V2.0
LES (AAL2)
according to
AF-VMOA-0145.00 V2.0

- VP aggregating
- Interface (port)
- Oversubscription (egress traffic)

:
:

UNI (ATIOP)
1 100

- Cross connection
- Type
- Connections

:
:

PVCs
bi-directional
asymmetric
up 2048 VPC/VCCs

- Number

- Traffic control functions


- Ingress traffic (towards ABUS)

UPC (Usage Parameter Control)


CAC (Connection Admission
Control)
VP shaping (ATIOP)
CAC

- Egress traffic (from ABUS)

STM-1 interface
- Termination
- Multiplex Section Protection

:
:

physical section
with ATIOP

Support of remote ATM services


- Local FOX transmission interfaces

- Remote services (third party IAD/CPE)

ADSL (DMT)
G.SHDSL
data services
PSTN user ports
ISDN user ports

IMA implementation
- Function unit
- Application

:
:

IMA

- Number of IMA groups


Support of service classes
- 1 IMA group per unit

ABB

page 11 of 68

:
:

ACONV
provisioning of ATM cells via
P12 circuits according to
PHY-0086.001 (V.1.1)
up to 14 per unit
service classes CBR-rt, CBRnrt, VBR-nrt, UBR

1KHW002006

Common features system specification

User Guide FOX515 System Specification (R8)

- IMA groups 2 14
- IMA group parameters (settable per interface)
- P12 links per group

- Cell frame length


- IMA group parameters (fixed)
- Group Symmetry Mode

1 service class (selectable)

up to 16
minimum required links per
group

32, 64, 128, 256 cells

- Maximum Differential Delay between links


- IMA group link synchronisation
- Transmission
- Reception

Symmetrical configuration
and operation
100 ms

:
:

CTC
CTC and ITC

- Scrambling function

activated

- Maintenance functions

- Performance monitoring

IMA group
Link group
loop back
cell counters

CES implementation
- Function unit
- Application

:
:

- Number of CES interfaces


- CES group parameters
- Type
- Supported functions

:
:
:
:

- Synchronisation of PDH traffic

- Maintenance functions

- Performance monitoring

8 Mbit/s signals
- Termination
- Protection 8 Mbit/s

:
:

- Multiplexing/demultiplexing from/into

2 Mbit/s signals
- Termination
- Protection 2 Mbit/s

:
:

- Adaptation

CES

ACONV
provisioning of
P12 circuits via ATM UNI
according to
AF-VTOA-0078.00 V2.0
up to 16 per unit
settable per service
2048 kbit/s (unstructured)
all functions of the FOX P12
traffic signal layer for
P0, P0-nc and P12x
synchronous (PBUS)
Adaptive
SRTS
all functions of the FOX P12
traffic signal layer
all functions of the FOX P12
traffic signal layer

PDH traffic

1KHW002006

page 12 of 68

physical section (optical)


1+1 physical section protection
4 P12 signals
unstructured or structured according to ITU-T G.704
physical section
1+1 physical section protection
SNCP/N and SNCP/I
structured, synchronous and

ABB

User Guide FOX515 System Specification (R8)

Common features system specification

- Termination and monitoring

- Cross connection
- Special functionalities

:
:

unstructured signals
structured, synchronous signals
structured and unstructured
V5.x
PRA
NT1-PRA
NT1-LL

physical section

:
:
:

n x 64 kbit/s
0 600 kbit/s
DXC 1/0

Subrate multiplexing
- Synchronous

- Asynchronous

- Transparent

48/56 kbit/s (V.110/X.30)


0.6 38.4 kbit/s (V.110/X.30)
0.6 19.2 kbit/s (I.460)
0.6 38.4 kbit/s (V.110/X.30)
0.6 19.2 kbit/s (I.460)
0 0.3 kbit/s (V.110/X.30)

Support of local voice interfaces

PSTN (subscriber line)


PSTN (exchange line)
Magneto line
Voice / E+M

Support of remote PDH services and interfaces


- Local FOX transmission interfaces

DSL (CAP, PAM16)


SHDSL (PAM16)
8 Mbit/s optical

- Remote services (FOX CPE)

data interfaces
(n x 64 kbit/s, n = 1 32)
and subrates 0.33...56 kbit/s)
PSTN interfaces
PSTN user ports
ISDN-PRA

SDH traffic functions


- Multiplexing/demultiplexing from/into

- Termination

:
:
:
:

STM-4 according to
ITU-T G.707
for VC-12, VC-3 and VC-4
STM-1 according to
ITU-T G.707
for VC-12 and VC-3
VC-4 locally
VC-3 locally
VC-12 locally and remote
VC-12 and VC-3
VC-12, VC-3 and VC-4
VC-12, VC-3 and VC-4
Linear trail protection
SNCP
SNCP

n x 64 kbit/s traffic signals


- Termination
- Transport rates
- Synchronous
- Transparent
- Cross connection

SDH traffic

ABB

Add and drop


Through connection
Cross connection
Protection VC-12

- Protection VC-3 and VC-4


STM-4 and STM-1 interface
- Termination

- Multiplex Section Protection

page 13 of 68

physical section
(optical and electrical)
with SYN4E or with SYNIO or
with 2 SYNUF

1KHW002006

Common features system specification

User Guide FOX515 System Specification (R8)

Support of remote SDH services


- Local FOX transmission interfaces
- Remote services (FOX CPE)

:
:

DSL (CAP, PAM16)


VC-12 termination and
data interfaces

Supported tributary traffic


- PDH

P12
E12
E31/32
STM-1 (electrical or optical)

- SDH
- Ethernet
-electrical

- optical

10BASE-T / 100BASE-TX /
1000BASE-T
100BASE-FX
1000BASE-LX / SX

Ethernet over SDH Ethernet switching

1KHW002006

Implementation
- Function unit

- Basic functions

- Physical interfaces
- Number of interfaces
- Interface types

:
:

up to 6
10BASE-T
100BASE-TX / 100BASE-FX
1000BASE-LX / SX

Transport (EoS)
- EoS

- Encapsulation procedure

- Virtual concatenation (VCAT)

- LCAS (Link Capacity Adjustment Scheme)

- Link protection

encapsulation of Ethernet
traffic for the transport via
SDH (VC-12, VC-3)
GFP framing according to
G.7041 (frame mapped)
VC-12 / VC-3 level
according to G.707
Protocol or fixed mode according to ITU-T G.7042
SNCP/N (VC-12 / VC-3)

Ethernet switching
- Switching points

- Number of VLAN instances

- VLAN support

Port and tag based


Tag stacking
Traffic prioritisation (4 levels)
4 queues (queuing profiles)
Rapid Spanning Tree
according to IEEE 802.1w

- Maintenance functions

Physical layer
Transport layer
VC-12, VC-3 layer

- Performance monitoring
- Ethernet PHY MIB-2, RMON
- GFP encapsulation
- VC-12, VC-3

:
:
:

packet (octet) counters


frame counters
counters

page 14 of 68

NEBRO
NEBRA
Transport (EoS)
Switching (Ethernet traffic)

Ethernet interfaces (6 / unit)


EoS endpoints (8 / unit)
up to 128

ABB

User Guide FOX515 System Specification (R8)

Common features system specification

Ethernet over SDH


Implementation
- Function unit

SYN4E

- Basic functions

Transport (EoS)

- Physical interfaces
- Number of interfaces
- Interface types

:
:

4
10BASE-T, 100BASE-TX,
1000BASE-T

Transport (EoS)
- EoS

- Encapsulation procedure

- Virtual concatenation (VCAT)

- LCAS (Link Capacity Adjustment Scheme)

- Link protection

encapsulation of Ethernet
traffic for the transport via
SDH (VC-12, VC-3, VC-4)
GFP framing according to
G.7041 (frame mapped)
VC-12 / VC-3 / VC-4 level
according to G.707
Protocol or fixed mode according to ITU-T G.7042
SNCP/N (VC-12 / VC-3 /
VC-4)

- Maintenance functions

Physical layer
Transport layer
VC-12, VC-3, VC-4 layer

- Performance monitoring
- Ethernet PHY MIB-2, RMON
- GFP encapsulation
- VC-12, VC-3, VC-4

:
:
:

packet (octet) counters


frame counters
counters

Implementation
- Function unit

NEBRE, SWITE

Ethernet switching

ABB

- Basic functions
- Physical interfaces
- Number of interfaces
- Interface types

Switching (Ethernet traffic)

:
:

up to 6
10BASE-T
100BASE-TX / 100BASE-FX
1000BASE-LX / SX

Ethernet switching
- Switching points

Ethernet interfaces (6 / unit)

- Number of VLAN instances

up to 128

- VLAN support

Port and tag based


Tag stacking
Traffic prioritisation (4 levels)
4 queues (queuing profiles)
Rapid Spanning Tree
according to IEEE 802.1w

- Maintenance functions
- Performance monitoring
- Ethernet PHY MIB-2, RMON

Physical layer

packet (octet) counters

page 15 of 68

1KHW002006

Common features system specification

User Guide FOX515 System Specification (R8)

Ethernet LAN to TDM WAN bridging


Implementation
- Function unit
- Basic functions
- Physical interfaces
- Number of LAN interfaces
- Interface types

Number of WAN interfaces


Interface types

ETER1

Bridging (Ethernet traffic)

:
:

up to 4
10BASE-TX half/full duplex
100BASE-TX half/full duplex
Access / Trunk
flow control
up to 64
PPP / HDLC encapsulation
and framing
Multilink PPP
Access / Trunk

:
:

Protection on WAN interfaces

1+1 SNCP/I for P0nc and


P12x signals
1+1 LTP for P0nc signals

Ethernet bridging
- Bridge instances

up to 8 logically independent
instances

- VLAN support

Port and tag based


shared VLAN learning
independent VLAN learning
star topology bridging
Traffic prioritisation (4 levels)
4 queues (queuing profiles)
Rapid Spanning Tree
according to IEEE 802.1w

- Maintenance functions
- Performance monitoring
- Ethernet PHY MIB-2, RSTP
Unfiltered events

Physical layer

:
:

packet (octet) counters


RSTP bridge counters
protection switching events

Implementation
- Function unit

SWITE

- Interfaces

- Powered device detection

6 access ports
10BASE-T/100BASE-TX
automatic according to
IEEE 802.3af

Available power
- max. power per SWITE board
- max. power per SWITE interface
- supported IEEE 802.3af power classes

:
:
:

Power over Ethernet provisioning (PoE)

63W
27W (manual power set)
class 1, with up to 4W
class 2, with up to 7W
class 3, with up to 15.4W

IP traffic

1KHW002006

page 16 of 68

ABB

User Guide FOX515 System Specification (R8)

Common features system specification

IP traffic signals
- Multiplexing/demultiplexing from/into
- Routing functions

:
:

- Bridging functions

Support of remote PDH services


- Local FOX transmission interfaces

- Remote services (FOX CPE)

DSL (CAP, 2B1Q, PAM16)


SHDSL (PAM16)
LAN interfaces
(n x 64 kbit/s, n=1 32)
routing and bridging functions

:
:
:
:
:
:

PCONV
4
1
2
240
112

:
:
:
:
:
:
:

2 x 2 Mbit/s
PCON2
10
1
8
480
224

selectable for V5
MCAS

PSTN User Ports


- SUBH1, PHLC3
- SUBH3, PHLC2
- PHLC1 (2 x SUBH3)
- MUSIC 700 - LESI8

:
:
:
:

10 sub. line IFs


30 sub. line IFs
60 sub. line IFs
8 sub. line IFs

ISDN-BA User Ports


- ISBUQ (2B1Q)
- ISBUT (4B3T)

:
:

8 ISDN BA
8 ISDN BA

IPSMG

:
:
:

TDM <-> IP
RTP
ITU-T G.711, 64 kbit/s
PCM A-law, silent suppression (Appendix II)

P12s traffic
OSPF V2.0
Frame Relay
transparent MAC bridge
port based virtual LAN
star bridge

V5 functions
V5 protocol processing
- Function unit
- V5.1 interfaces
- V5.2 interfaces
- Max. number of V5.2 link accesses
- Capacity of PSTN user ports V5.2
- Capacity of ISDN BA user ports V5.2
incl. processing of p- and f-data
- Integrated IFs G.703 for V5 link access
- Function unit
- V5.1 interfaces
- V5.2 interfaces
- Max. number of V5.2 link accesses
- Capacity of PSTN user ports V5.2
- Capacity of ISDN BA user ports V5.2
incl. processing of p- and f-data
- Access for PSTN user ports

NGN Access Gateway


Access Gateway characteristics
- Function unit
- Media Gateway functions
- Voice conversion
- Voice (IP) transport protocol
- Codec types, characteristics

ABB

page 17 of 68

1KHW002006

Common features system specification

User Guide FOX515 System Specification (R8)

- Modem- and FAX service

- Echo cancelling

- In-band signalling (DTMF, dial tone, ringing etc) :


DTMF relay service
:
- Clear channel
:

G.729 A (Codec) and B (silence suppression)


in-band transport supported
FAX relay service ITU-T T.38
ITU-T G.168
16 ms 128 ms
detection and generation
according to RFC 2833
64 kbit/s
(ISDN-BA B-channels)

- Signalling and control functions


- PSTN signalling conversion
- Set up / release control
- Interface to MGC

:
:
:

H.248 messages
H.248 / MEGACO
H.248.1 v1
primary and secondary

- Jitter buffer (accommodate IP delay variation)

- Max. number of active channels


- Traffic handling capacity (@ PDR < 0.04%)

:
:

200 ms
- fixed mode
- adaptive mode
200
10000 BHCA

:
:

ITU-T Q.931
SIGTRAN (IUA/SCTP)

Differentiated services (control and media traffic)

- VLAN
- VLAN tagging (control and media path)
- User priority (control and media path)

:
:

IEEE 802.1Q
IEEE 802.1p

User port access


Uplink interface
Functional parameterisation
Interoperability

:
:
:
:

16 x P12s (480 POTS)


10BASE-T / 100BASE-TX
Custom parameter sets
approved for selected MGC
brands

PSTN User Ports


- SUBH1, PHLC3
- SUBH3, PHLC2
- PHLC1 (or 2 x SUBH3)
- MUSIC 700 - LESI8

:
:
:
:

10 subscriber line IFs


30 subscriber line IFs
60 subscriber line IFs
8 subscriber line IFs

ISDN-BA User Ports


- ISBUQ (2B1Q)
- ISBUT (4B3T)

:
:

8 ISDN BA
8 ISDN BA (on request)

Access Gateway characteristics


- Function units
- ADSL
- SHDSL

:
:

IPLM1, IPLM2, IPLM4


IPLM6

- Gateway functions
- ATM <-> Ethernet Encapsulation

Bridge mode (RFC 1483)


PPPoE (RFC 2516)
IPoE
PPPoA

- Signalling Gateway (ISDN-BA signalling)


- D-channel frames
- Interface to ASP
- Network IF
- Quality of service and resource allocation

ADSL and SHDSL based broadband access aggregation

1KHW002006

page 18 of 68

ABB

User Guide FOX515 System Specification (R8)

Common features system specification

IPoA
- Layer 2 switching / bridging
- Modes

- Access control
- Learned MAC addresses
- STP support

:
:
:

- VLAN support
- Tagging

- Flooding and broadcasting


- Bridging modes for VLAN

:
:

- Port membership
- static

- dynamic

Frame tagging (IEEE 802.1q


and 802.1ad)
Tag stacking
Supported
Residential bridging
Restricted full bridging
Unrestricted full bridging
Lists of egress, inhibited,
untagged ports
GARP VLAN Registration
Protocol (GVRP)

- DHCP

Relay agent (RFC 2131)


Option 82 (RFC 3046)

- TV multicast support
- Number of groups

up to 256

- Group memberships

static
dynamic, IGMPv2 snooping
(RFC 2236)

- Quality of Service (QoS)


- Queues

- Scheduling mechanism

- Input rate limiting (IRL)


- Output rate limiting (ORL)

:
:

4 per ATM port


8 per physical Ethernet port
Strict priority
Minimum and maximum
bandwidth guarantees
Weighted excess bandwidth
distribution
per AAL5 interface (profiles)
per ATM / Ethernet port

- Access control
- Packet filtering
- Internet access control mechanisms

ABB

Static bridge forwarding


Dynamic bridging
Fix MAC address
(IEEE 802.1d)
Global / per port
up to 4000
ADSL/SHDSL ports

:
:

Filters / rules and decision


trees
MAC based authentication
MAC address control lists
IP address control lists
Sticky Bridge Ports
Forwarding database (FDB)
conflict traps
MAC address tracking
Dedicated queue for the control
plane per ADSL/SHDSL port

Uplinks
- Electrical interface
- Optical interfaces (IPLM1 only)

:
:

- Link Aggregation

100BASE-TX / 1000BASE-TX
100BASE-FX / 1000BASESX/LX SFP modules
LACP (IEEE 802.3ad)

ADSL access
- ADSL

ITU-T G.992.1

page 19 of 68

1KHW002006

Common features system specification

User Guide FOX515 System Specification (R8)

- ADSL2
- ADSL2+
- Line rates
- Individually configurable
- upstream
- downstream
- Capacity
- Modularity
- Clusters
SHDSL access
- G.SHDSL
- G.SHDSL.bis
- Line rates
- Individually configurable
- ITU-T G.991.2
- ITU-T G.991.2 Annex F/G
- Pair bonding (2 pairs)
- Capacity
- Modularity
- Clusters
Management
- Unit and NE integration

:
:

ITU-T G.992.3
ITU-T G.992.5

:
:
:

in steps of 32 kbit/s
up to 1 Mbit/s
up to 24 Mbit/s

:
:

24 ports
up to 144 ports

:
:

ITU-T G.991.2
ITU-T G.991.2 Annex F/G

:
:
:
:

in steps of 8 kbit/s
200 kbit/s 2320 kbit/s
768 kbit/s 5696 kbit/s
SHDSL line according to ITUT G.994.1 Annex B
(for HS mode only)

:
:

24 ports
up to 144 ports

UCST / FOXMAN-UN
SNMP
CLI
(launch via UCST)

- IP DSLAM functionalities

Function unit
- Data type

:
:

- Processing for CAS signalling

- Max. number of participants


- Max. number of conferences
- Proposed max. number of participants
Parameters
- Attenuation of input signal
- Attenuation of output signal
- Noise suppression

:
:
:
:
:
:
:

Function unit
- Data type

:
:

- Processing for CAS signalling

- Max. number of participants


- Max. number of conferences
- Max. number of participants per conference

:
:
:

Parameters
- Attenuation of input signal
- Attenuation of output signal
- Noise suppression

:
:
:
:

Conference functions

1KHW002006

page 20 of 68

COBUV
A-law coded voice in P0, incl.
CAS
bit-wise AND of all input signalling
64
21
8
settable per participant
0, 3, 6 and 9 dB
0, 3 dB
selectable
3 steps
NEMSG
A-law coded voice in P0, incl.
CAS
bit-wise AND of all input signalling
32
8
17
settable per participant
0, 3, 6 and 9 dB
0, 3, 6 and 9 dB
selectable
3 steps

ABB

User Guide FOX515 System Specification (R8)

Common features system specification

Protection
Section protection

Implemented by units with


transmission interface

Multiplex Section protection STM-4


- SDH

1 SYN4E

Multiplex Section protection STM-1


- SDH

1 SYN4E
1 SYNIO
2 SYNUF

2 ATIOP

2 Mbit/s (P12s)
(with PBUS units only)
VC-4, VC-3, VC-12
(on SYN4E)
2 Mbit/s and 64 kbit/s
(P12x, P0 and P0-nc)
(with PBUS units only)
VC-4, VC-3, VC-12
(on SYN4E)
VC-12
VC-3

- ATM
Subnetwork protection for signals
- SNCP/N

:
- SNCP/I

:
:

Linear trail protection

Equipment protection
- Traffic unit type
- units without front interfaces

- units with LAN front interfaces


- Protection type

:
:

- Unit switch-over

- Implications of EQP switch-over

Performance monitoring
Monitoring points
- PDH

ITU-T-G.826

- SDH

2 Mbit/s traffic signals


SULIC-NTU
(64 kbit/s TS required)
UNIDA
(64 kbit/s TS required)
VC-12
VC-3
VC-4
RS and MS in STM-1
RS and MS in STM-4

- ATM
-STM-1 UNI

- ATM traffic

ACONV
(EQP for SYNAC is a
FUTURE OPTION)
IPSMG
n+1
hot standby
non-revertive
automatic unit failure driven
and
UCST command
unit restart
restart of services

Monitoring of traffic signals

ABB

page 21 of 68

VC-4
RS and MS in STM-1
cell counters

1KHW002006

Common features system specification

User Guide FOX515 System Specification (R8)

- Ethernet
- Ethernet PHY

event counters MIB-2


interface statistics
RMON
event counters MIB-2
interface statistics
RMON
GFP encapsulation counters

- Ethernet over SDH

Trail monitoring with TTI


- PDH
- SDH

:
:

2 Mbit/s (ECC mode)


VC-12
VC-3
VC-4
RS in STM-1
RS in STM-4

Function unit
Test purposes

:
:

COBUV and COBUX


channel performance
signal delays

Diagnostic functions

1KHW002006

page 22 of 68

ABB

User Guide FOX515 System Specification (R8)

Common features system specification

Synchronisation
General
Basic configurations

:
:
:

PETS
PETS and SETS
SETS only
(PETS locked to SETS)

Function units
- PETS
- SETS

:
:

COBU<X>
SYNI<X>, SYNUF, SYN4E,
ATIOP

Selection algorithm
- QL based
- Priority based
- Switching
- Configurable Hold off time
- Configurable wait to restore time

:
:
:
:
:

QL 1 ... 15
1 ... 7/8 (1 highest)
revertive
0-60 s
0-720 s

:
:
:

P12s terminated
P12s monitored
P0 signals

- External 2048 kHz sources (ITU-T G.703)


- Internal source

:
:

2 (ESI-1 2)
50 ppm

Filter for clock recovery selectable

:
:

high Q
low Q

:
:

2.5 Hz
< 0.5 dB

:
:

40 Hz
< 0.5 dB

Synchronisation outputs (ESO)


- Number
- Squelching configurable per

:
:

3 (ESO-1 3)
- source selected
- QL of NE (1 ... 15)

Equipment protection

requires two control units

Architecture
- NE level

- Inter sector SETS synchronisation

- SETS block diagram (per sector)

1 SETS system per


ABUS/SBUS sector
Agent sector synchronises to
Prime sector
see figure below

PETS
Timing sources for PETS
- Traffic signals (up to 4)

Jitter transfer characteristic


- High Q
- Max. Bandwidth
- Jitter gain
- Low Q
- Max. Bandwidth
- Jitter gain

SETS

ABB

page 23 of 68

1KHW002006

Common features system specification

User Guide FOX515 System Specification (R8)

In ESO-4/ESO-SDH (T4) non


SETS locked mode, Select A
and Select B may share the
same timing sources, but they
are autonomous in terms of
selection.
Sync Sources:
SDH (T1)
STM-1
PDH (T2)

Select A

Select C

Squelch

2 Mbit/s

ESO-4/ SDH (T4)


2MHz

ESI-1 (T3)
2 MHz

Squelch

SETG
(PLL)

Select B

Int ernal Timing (T0)


SBUS, STM-1

SETS

Int ernal

1KHW002006

Specification
- Optimised for 2048 kbit/s hierarchy
- Accuracy under free-running conditions
- Minimum pull in range
- Wander generation in locked mode

:
:
:
:

- Wander tolerance

- Jitter tolerance for 2048 kHz, 2048 kbit/s

Option 1, ITU-T G.813


better than 4.6 ppm
4.6 ppm
Table 1, 2, 3 /G.813
Figure 1, 2 /G.813
Table 8, 9, 10 /G.813
Figure 5, 6, 7 /G.813
Figure 9/G.813

- Noise transfer characteristic


- Min Bandwidth
- Max. Bandwidth
- Gain in the pass band
- Short-term phase transient response
- Long-term phase transient response
- Phase response to input signal interruption

:
:
:
:
:
:

1 Hz
10 Hz
lower than 0.2 dB
Figure 12/G.813
Figure 14/G.813
G.813 10.3

Timing sources for SETS


- Traffic signals

- External 2048 kHz input (ITU-T G.703)

STM-1 MS (T1)
2 Mbit/s terminated (T2)
2 Mbit/s monitored (T2)
1 ESI-1 (T3)

Synchronisation Output (ESO)


- Number
- Mode of operation

:
:

- Squelching configurable per

Synchronisation Selection Process (Select B)


QL /SF hold off time
QL /SF wait to restore time

:
:
:

page 24 of 68

1 ESO-4/SDH (T4)
- SETS locked
- Non SETS locked
- selected source
- QL of NE (1...15)
Figure A.1/ETS 417-6-1
0 to 60s
0 to 720s

ABB

User Guide FOX515 System Specification (R8)

Common features system specification

Equipment protection
- SDH (SBUS)

- ATM (ABUS)

Relevant Standard Document

ETS 300 417-6-1

Selection
- Auto-selection (SETS Select B/A, PETS):

- Forced free-run
- Forced holdover

:
:

4.12
(QL-enabled mode corresponds
to QL based selection algorithm
QL disabled mode corresponds to Priority based selection algorithm)
Select A fix to Auto-selection
SETS Select B, PETS
SETS Select B (only if HO frequency available)

Timing source (SETS Select B, Select A, PETS)


- Forced switch according to ETS 300 417-6-1
- Manual switch
- Clear switch
- Set lockout
- Clear WTR

:
:
:
:
:

4.11.2.2
4.11.2.3
4.11.2.1
4.11.1.1
4.9

Status
- Timing Source

QL
Priority
Available
Failed
Not supervised

- SETS Clock operation mode

locked
free-run
holdover

- PETS Clock operation mode

(not applicable)

SETS (STM-4/1 aggregate unit)

Loss of External Clock source


Loss of clock source
PDH<X>/SDH<Y>
Loss of SEC Timing input
Loss of ESO Timing inputs
SEC Source not Primary
ESO Source not Primary
SETS in Holdover
SETS HW Failure
SEC Source out of limits

- PETS (COBU<X>)

Loss of external clock 1, 2

with 1 SYN4E unit or


with 2 SYNIF / SYNIC or
SYNUF units in the same
SBUS sector
with 2 ATIOP units in the
same ABUS sector

Maintenance and Diagnostics

Fault management

ABB

page 25 of 68

1KHW002006

Common features system specification

User Guide FOX515 System Specification (R8)

Wrong impedance external


clock 1, 2
Loss of clock source PDH<X>

SSM and QL processing


SSM transmission
- in SDH signals
- in PDH signals
- SSM mode
- FOX proprietary ECC mode

1KHW002006

S1 byte of STM-4/1 MS

any Sa bit of 2 Mbit/s acc. to


G.704
Sa4 in bit of 2 Mbit/s acc. to
G.704,

Mapping of the QL
- in receive direction

SETS mapping table


overrides QL by QL 1 to 15
depending on received QL

- in transmit direction

SETS mapping table


overrides QL by QL 1 to 15
depending on NE QL

Unit routing table, ESO

SETS, PETS timing source configuration

override by Do not use


(QL = 15, SSI = 0, ESO =
squelched) depending on timing
source selected to avoid network
timing loops
assignment of a fix QL

page 26 of 68

ABB

User Guide FOX515 System Specification (R8)

Common features system specification

System control and management functions


Control system
Basic control system
Central system control

:
:

Traffic units

distributed processor system


dedicated unit with master
processor
local slave processors

Management Information Base (MIB)


- Configuration data
- Unit software (units with SW download only)

:
:
:

control unit (COBU<X>)


MIB
MIB

Physical implementation of MIB

Capacity of PCMCIA card

PCMCIA card
(removable)
8, 16 MB

Equipment protection of the control unit


- Type of protection

:
:

- MIB of redundant unit


- Control unit switch-over

:
:

- Implications of the switch-over on traffic signals:


- automatic and UCST commanded switchover
- UBUS (UNIDA - UNIDA X.24)
:
- PBUS (LOMIF - LOMIF 2 Mbit/s transparent)

- removal of active control unit


- UBUS (UNIDA - UNIDA X.24)
- PBUS (LOMIF - LOMIF 2 Mbit/s transparent)

:
:

Real time clock

Unit software
- EM controlled SW download (for ESW)
- Control units
- Traffic units

:
:

1+1 (slots 11 and 12)


hot standby
non-revertive
permanently updated
automatic failure driven and
UCST command

short interruption
250 s
insertion of one 0-bit corresponding to an interruption of
488 ns
interruption 4 ms
insertion of 1 4 0-bits corresponding to an interruption
of 1952 ns
50 ppm

NE software system

- CPE

- FTP server based SW download (for ESW)


- CPE
- IP DSLAM
- ADSL
- SHDSL

ABB

page 27 of 68

COBU<X>
ABUS units
PBUS units
SBUS units
new UBUS units
MUSIC 200 (R4)
Line Runner SHDSL DTM

MUSIC 700 family

:
:

IPLM1, IPLM2, IPLM4


IPLM6

1KHW002006

Common features system specification

User Guide FOX515 System Specification (R8)

- Embedded Software (ESW)

legacy UBUS units

Configuration management for

NE incl. ESW
traffic functions

Performance management for

NE
traffic signals

Management functions

1KHW002006

Fault management
- Hardware failures
- ESW configuration/operation
- Failures and performance
Alarm generation and reporting
- Generation and severity
- Indication

:
:
:

NE and units
units and CPE
traffic signals

:
:

- Reporting

programmable
local indicators and relay
contacts
alarm lists
logbook
remote access

Inventory management

for hardware and software

Management tools and versions


- FOX platform (NEs, units and CPEs)

- IP DSLAM functionality (IPLM<X>)

UCST R8B
FOXMAN-UN R8B
CLI
(launch via UCST)

page 28 of 68

ABB

User Guide FOX515 System Specification (R8)

Common features system specification

Performance control and diagnostic functions


System level
System level
- Alarm system
- Alarm indicators
- Lists

:
:

- Inventory data

- Software installation status

Functional level
- Diagnostic
- Traffic functions

LED and relay contacts


NE fault list
logbook
for hardware and NE software system
for ESW installation and
installation progress

Functional level

- Synchronisation functions

- System functions

protected cross connections


U/PBUS usage
MSP
equipment protection
PETS, SETS
ESO SDH
system control /
equipment protection ECC
and OSPF router

Unit level
- Fault indicators

- Test loops
- State indication:
- Performance monitoring

:
:
:

Central diagnostic for traffic signal channels


- Units with diagnostic function
- Functional blocks

:
:

COBUX, COBUV
Test signal generator
signal analyser

- Test signal
- Type

8-bit pattern and


pseudo random bit patterns
n x 64 kbit/s and 2 Mbit/s
unstructured

unit hardware and traffic


signals
unit specific
Traffic signals
Traffic signals G. 826
(selected units)

Central diagnostics

ABB

- Structure and bandwidth

- Analyses
- 8-bit pattern
- Pseudo random bit pattern

:
:

- Channel connection

page 29 of 68

matching patterns
performance monitoring
channel delay
via cross connect

1KHW002006

Common features system specification

User Guide FOX515 System Specification (R8)

Compatibility with other FOX equipment


Compatible platform

FOX

Accommodation of legacy units in subrack

FOX traffic units (release for


FOX subracks as specified in
the release note)

Remote equipment

CPEs compatible with FOX


traffic units

Interfaces (applications based on the platform)

external traffic and management

Synchronisation

SSI
(P12s signals only)

- New units to existing systems

only if specified

- New front access connectors to existing system

not compatible

- UCST to legacy systems

FOX-U
FOX-U/M (-U/E)
DSL product family

Backward compatibility

1KHW002006

page 30 of 68

ABB

User Guide FOX515 System Specification (R8)

Common features system specification

Architecture
System
System architecture

fully modular
open architecture

Implementation

configurable
according to requirements

- Control units

type COBU<X>

- Subsystems

MIB of the NE
PETS
Processing of Management
Com
Control of BUS access
UBUS access
Diagnostics
Conference functions

- Control units and supported features


- Diagnostics

COBUX, COBUV

- ECC

COBUX, COBUV

- Conference function

COBUV

- 8 x 2 Mbit/s

COBUX, COBUV

- 4 x 2 Mbit/s

COBUL

-128 x 2 Mbit/s

COBUX 212, 219 (R5)


COBUV 217, 220 (R5)
COBUL 216 (R4)

- 40 x 2 Mbit/s

COBUX 213, 223 (R5)


COBUV 218, 224 (R5)

control units R5

system control and


PETS
SETS
power supply

traffic units without front access or LAN interfaces

Implementation of external interfaces

on removable units

Unit types
- Units with ABUS access

ABUS units

- Units with PBUS access

PBUS units

- Units with SBUS access

SBUS units

- Units with UBUS access

UBUS units

- Units without (traffic) bus access

Special units

Unit software (EWS)

down loaded

System control

- UBUS highways

- PBUS highways

- ATM functionality
Functional levels of equipment protection
- System function level

- Traffic function level

ABB

page 31 of 68

1KHW002006

Common features system specification

User Guide FOX515 System Specification (R8)

Compatibility to existing FOX equipment

for traffic units and functions

Configuration

software based with


UCST and FOXMAN-UN

Capacity

1215000 cells/s

Logical structure

ATM cells
UNI cell format

Physical structure

32 x 19.44 Mbit/s
per sector
linear with pairs of slots interleaved for MSP

- VC-4 terminating

2 x STM-1 (63 x VC-12 or


3 x VC-3))

- Add and drop to/from STM-4/1

VC-12 and VC-3

- Through connection

VC-12 and VC-3

Logical structure

63 x VC-12 (TU-12) or
3 x VC-3 (TU-3)

Physical structure

4 x 8 x 19.44 Mbit/s
per sector
linear with pairs of slots interleaved for MSP

Capacity

128 x 2 Mbit/s
with and without CAS

Logical structure

linear 128 x 2 Mbit/s


with and without CAS

Physical structure

32 x 16 Mbit/s
non segmented linear

Capacity

8 x 2 Mbit/s
with and without CAS

Logical structure

2 sets of highways each 4 x 2


Mbit/s
with and without CAS

Physical structure

8 x 4 Mbit/s
segments, non linear

ABUS

SBUS
Capacity

PBUS

UBUS

1KHW002006

page 32 of 68

ABB

User Guide FOX515 System Specification (R8)

Common features system specification

1 segment with overlapping


highway sets

ABB

page 33 of 68

1KHW002006

Common features system specification

User Guide FOX515 System Specification (R8)

Management communication
Element Manager
Element Manager

UCST R8C

Element Manager System

FOXMAN-UN R8C

:
:
:

MCN for FOX


COBUV, COBUX
unnumbered PPP links with
dynamic OSPF routing

:
:
:

P12s
P0-nc
P12

:
:
:

STM-4/1 SOH bytes


192 kbit/s, 576 kbit/s
RS and MS (STM-4/1)

:
:

ATM cells
64 kbit/s, 192 kbit/s
576 kbit/s
ATM, IMA

Management communication structures


ECC
- Application
- Function unit
- Structure
- ECC channels (MCN network)
- ECC over PDH
- Transport
- Bandwidth
- Traffic signal layer
- ECC over SDH
- Transport
- Bandwidth
- Traffic signal layer
- ECC over ATM
- Transport
- Bandwidth
- Traffic signal layer
- ATM characteristics
- QoS
- PCR
- CDVT

:
:
:
:

CBR (CBR.1)
80.1 (70.8) kbit/s
240.4 (212) kbit/s
720.4 (636) kbit/s
5000 (600) s

(Values in brackets apply up to the UCST R6A SP01)


- Encapsulation over ATM Adaptation Layer 5 :

- NE interfaces for PDH based ECC


- Number of channels
- Bandwidth PDH channels
- Use of interfaces

- NE interfaces for SDH based ECC


- Number of channels
- Bandwidth SDH channels
- Internal interfaces

1KHW002006

page 34 of 68

:
:
:

RFC 2364
(incl. AAL5 <-> P0-nc PPP
Relay function)
max. 32
64 1984 kbit/s (P0-nc)
16 kbit/s (TS0 in P12s)
ECC over PDH
ECC over ATM
(transport in ATM cells)

:
:

max. 8
192 kbit/s, 576 kbit/s

ECC over SDH


(tunnelling in OSI DCN)

ABB

User Guide FOX515 System Specification (R8)

Common features system specification

- Cumulated bandwidth PDH and SDH per NE


- NE ECC interface to MCN

:
:

- EM(S) interface to ECC

- ECC addressing

EOC
- Application
- Function unit
- Structure

:
:
:

max. 2048 kbit/s


P0-nc
(internal cross connect)
QX-interface (10BASE-T)
F-interface (RS-232C)
Tunnelling for
- OSI DCN
- ECC over ATM
IP addresses

:
:
:

management of legacy FOX


COBUV, COBUX
proprietary multi-path
based on SIFOX
SIFOX / F-interface
SIFOX / RS-232 C
proprietary EOC addresses

:
:

9600 bit/s
19200 bit/s

LAN (WAN)
- Type
- NE interface
- EM(S) interface

:
:
:

Ethernet 10BASE-T
QX-interface
Ethernet 10BASE-T

Q-BUS
- Structure

local bus
based on RS-485

NE management

access to remote Q-BUS via


remote FOX
COBUX, COBUV
remote replication of the managing Q-BUS interface

- NE interface to EOC
- EM(s) interface to EOC
- Addressing
Bandwidth
- Mixed NEs FOX-U/M (-U/E)/-U and FOX515
- NEs FOX515 only up to

- NE interfaces to Q-BUS
- Q1-slave interface
- Q1-master interface
- Purpose
- Implementation
- Function
- Management access to Q-BUS
- EM(S) direct access
- EM(S) access via Q1-master interface
- Addressing
- Bandwidth
- Mixed NEs FOX and legacy FOX
- NEs FOX only up to

:
:

RS-232 C via RS-232 C / RS485 converter


via FOX with Q1-master
interface
proprietary EOC addresses

:
:

9600 bit/s
57600 bit/s

COBUX, COBUV
COBUL
OSPF V2.0 (RFC 2178)

Routing functions
IP routing
- Function unit
- Routing protocol
- Router interfaces
- COBU<X>
- COBUX, COBUV
- COBUX, COBUV

ABB

page 35 of 68

:
:
:
:

F, Q1, QX,
OSI tunnel
ECC over
- PDH
- SDH
- ATM

1KHW002006

Common features system specification

User Guide FOX515 System Specification (R8)

(ECC functionality not available with COBUL)

1KHW002006

OSI routing
- Function unit
- Routing protocol
- Router interfaces

:
:
:

COBUX, COBUV
IS-IS (level 1)
QX, OSI tunnels

HDLC routing
- Function unit

- Routing protocol
- Router interface

:
:

COBUX, COBUV
COBUL
proprietary
Q1-interface

page 36 of 68

ABB

User Guide FOX515 System Specification (R8)

Common features system specification

Cross connections and delays


PBUS cross connect
Type
Capacity
- 2 Mbit/s equivalents max.
- 64 kbit/s equivalents max.
Protection between access ports
- Bi-directional (quality criteria for input selection)

non-blocking
structured and non structured
signals

:
:

128 x 2048 kbit/s


4096 x 64 kbit/s

2 Mbit/s
n x 64 kbit/s (n = 1 ... 31)
status monitor UCST

- Control

Broadcasting

2 Mbit/s
n x 64 kbit/s (n = 1 ... 31)

Delay assignment
- Single TS and consecutive TS n x 64 kbit/s
- Non consecutive TS n x 64 kbit/s

:
:

minimum delay
constant delay

Delays (access points cross connect)


- Unstructured signals P12x (PBUS - PBUS)

min.
max.

14 s
48 s

- Structured signals P12s (PBUS - PBUS)


- Minimum delay

min.
max.
min.
max.

21 s
380 s
21 s
501 s

min.
max.
min.
max.

21 s
378 s
21 s
499 s

min.
max.
min.
max.

125 s
248 s
125 s
369 s

min.
max.
min.
max.

125 s
246 s
125 s
367 s

typ.
typ.

139 s
583 s

Traffic signal delays PBUS and UBUS

- Constant delay
- Structured signals P12s (PBUS - UBUS)
- Minimum delay
- Constant delay
- Structured signals P12s (UBUS - PBUS))
- Minimum delay
- Constant delay
- Structured signals P12s (UBUS - UBUS)
- Minimum delay
- Constant delay

:
:

:
:

:
:

Traffic signal delays SBUS and PBUS


Delays (2 Mbit/s traffic signal reference)
- TM (loop on STM-4 or STM-1):
- SYNAM SYN4E SYN4E SYNAM
- LOMIF SYN4E SYN4E LOMIF

ABB

page 37 of 68

:
:

1KHW002006

Common features system specification

User Guide FOX515 System Specification (R8)

- TM (loop on STM-1; X = F, O, C):


- SYNAM SYNI<X> SYNI<X> SYNAM

typ.

90 s

- ADM:
- SYN4E STM-4 VC-4 SYN4E STM-4
- SYN4E STM-4 VC-12 SYN4E STM-4
- SYN4E STM-1 VC-4 SYN4E STM-1
- SYN4E STM-1 VC-12 SYN4E STM-1

:
:
:
:

typ.
typ.
typ.
typ.

16 s
47 s
16 s
47 s

- ADM:
- SYNIO <m> IF_1 SYNIO <m> IF_2

typ.

16 s

ATM cell delays


STM-1 interface
- ATIOP (STM-1) ATIOP (STM-1)
IMA interface
- ATIOP (STM-1) ACONV (IMA, 2 links)
loopback
ACONV (IMA, 2 links) ATIOP (STM-1)
ADSL interface
- ATIOP (STM-1) ADAC<X>
ADSL modem (ATM)

Traffic delay CES


Delay of E1 signal(s) via CES
- LOMIF (P12) ACONV ATIOP (STM-1)
loopback
ACONV ATIOP (STM-1) LOMIF (P12)

1KHW002006

page 38 of 68

ABB

User Guide FOX515 System Specification (R8)

Common features system specification

Protection switching restoration times


SNCP
Restoration time for a traffic signal with
- P0_SNCP/I
- PBUS
- UBUS

:
:

max.
max.

1.125 ms
1.125 ms

MSP
STM-4 SDH
- Restoration time for bidirectional MSP on section
- SYN4E - SYN4E
- typical
:
- maximum
:

25 ms
< 50 ms

STM-1 SDH
- Restoration time for bidirectional MSP on section
- SYN4E - SYN4E
- SYNIO - SYNIO
- SYNUF - SYNUF
- typical
:
- maximum
:

25 ms
< 50 ms

- SYN4E - other vendor equipment


- SYNIO - other vendor equipment
- SYNUF - other vendor equipment

:
:
:

not specified
not specified
not specified

STM-1 ATM
- Restoration time for MSP on section
- ATIOP ATIOP
- ATIOP - other vendor equipment

:
:

< 50 ms
not specified

IMA interface
ATIOP (STM-1) ACONV LOMIF
LOMIF ACONV ATIOP (STM-1)
- Restoration time ATM cells
- 1 link out of 2 fails
- 2 links out of 4 links fail

:
:

- Restoration time E1 (CES via IMA)

typical 8 ms
typical 8 ms
max. depending on
- link delay(s)
-M
- number of links
typically 50 ms
max. depending on
- link delay(s)
-M
- number of links

IMA

N+1 equipment protection

ABB

page 39 of 68

1KHW002006

Common features system specification

1KHW002006

User Guide FOX515 System Specification (R8)

ACONV
- restoration time

not specified
depending on
- services
- traffic load

IPSMG
- restoration time

not specified
depending on
- services
- traffic load

page 40 of 68

ABB

User Guide FOX515 System Specification (R8)

Common features system specification

Interfaces
Traffic interfaces

Implementation
Physical implementation
- Traffic interfaces
- Traffic functions

:
:

traffic units
traffic units and
control units

Characteristics and specifications


- Summary of units and specifications
- Details

refer to technical unit descriptions

Released units

specified per NE
refer to release note FOX /
UCST R8C Release Note
FOX / UCST

Function unit

COBU<X>

ESI-1:
- Synchronisation system
- Frequency
- Galvanic isolation from NE and battery
- Impedance
- According ITU-T G.703, section 10

:
:
:
:
:
:

SETS/PETS
2048 kHz
yes
configurable
75 or
120 (R2A)
| Zin | 3 k

:
:
:
:

PETS
2048 kHz
yes
configurable

:
:

75
| Zin | 3 k

Resistibility to surge voltages ESI-1 and ESI-2

1.2/50 s impulses
U = 100 V

Insulation signal pins of ESI-1 and ESI-2


- ECLK2MIN<X>

1 kV/50 Hz/60 s

Specification

Units implemented

Synchronisation interfaces
Inputs

- High impedance
ESI-2:
- Synchronisation system
- Frequency
- Galvanic isolation from NE and battery
- Impedance
- Impedance
- According ITU-T G.703, section 10
- High impedance

ABB

page 41 of 68

1KHW002006

Common features system specification

User Guide FOX515 System Specification (R8)

- ECLK2MGUARD<X> to earth

1 kV/50 Hz/60 s

ESO-1:
- Synchronisation system
- Frequency
- Galvanic isolation from NE and battery
- Impedance according ITU-T G.703, section 10

:
:
:
:

PETS
2048 kHz
yes (R2A)
75

ESO-2 and ESO-3:


- Synchronisation system
- Frequency
- Galvanic isolation from NE and battery
- Impedance according ITU-T G.703, section 10

:
:
:
:

PETS
2048 kHz
no
75

ESO-4:
- Synchronisation system
- Frequency
- Galvanic isolation from NE and battery
- Impedance according ITU-T G.703, section 10

:
:
:
:

SETS
2048 kHz
yes (R2A)
75
120 (R2A)

Resistibility to surge voltages ESO-1 ESO-4

1.2/50 s impulses
U = 100 V

Insulation signal pins


- ESO-1 and ESO-4
- ECLK2MOUT<X>
- ECLK2MGUARD<X>
- ESO-2 and ESO-3

:
:
:
:

(R2A)
1 kV/50 Hz/60 s
1 kV/50 Hz/60 s
no galvanic separation

F-interface
- Application Layer
- Transport Layer
- Network Layer
- Data Link Layer
- Physical Layer

:
:
:
:
:

proprietary layer 7
TCP
IP
PPP
RS-232

Q1-interface
- Application Layer
- Transport Layer
- Network Layer
- Data Link Layer
- Physical Layer

:
:
:
:
:

proprietary layer 7
TCP
IP
PPP
RS-485

QX-interface
- Application Layer
- Transport Layer
- Network Layer
- Data Link Layer
- Physical Layer

:
:
:
:
:

proprietary layer 7
TCP
IP
IEEE 802.3 Ethernet
10BASE-T
half-duplex

Outputs

Management interfaces
EMS and FOX

1KHW002006

page 42 of 68

ABB

User Guide FOX515 System Specification (R8)

Common features system specification

OSI-tunnel for TCP/IP management com.

Virtual LAN
via COBU<X>

Q1-master interface
- Application

- Physical Layer

Remote Q-bus master access


via COBUX, COBUV
RS-485

ECC interfaces MCN to FOX


- ECC over PDH

- ECC over SDH

- ECC over ATM

- FOX internal access for all ECCs

units supporting the


P12 traffic layer
units supporting the
RS and MS traffic layer (STM1)
units supporting the
ATM and/or IMA traffic layer
P0-nc via UBUS

:
:
:
:

P0-nc via UBUS


E1, E2 and F1
D1 D3
D4 D12

Function unit

COBU<X>

Alarm inputs:
- Number
- User defined names for input signals
- Active signal level

:
:
:

4
yes
configurable via EM
- active ground
- active open.

- Thresholds for detection


- Reference

- "Ground state range

- "Open state range

positive leg of the battery


(earth)
-8 V ... +75 V
with respect to reference
-75 V -16 V
with respect to reference
a current sink of at least 1 mA
with an impedance not higher
than 20 kOhm
to 1.2/50s surge impulses
with
U = 2000 V
COBU<X>

MCN to FOX

Access to SOH of STM-4/1


Access to SOH bytes
Order wire (EOW) and user channel
RS DCC (ECC via SDH)
MS DCC (ECC via SDH)

Alarm interfaces

ABB

- Load equivalent of input @ voltage of -16 V

- Surge immunity

- Physical implementation

Alarm outputs:
- Number
- Type

:
:

page 43 of 68

2
solid state relays
double throw
overload protected

1KHW002006

Common features system specification

User Guide FOX515 System Specification (R8)

- Use

- Physical implementation

alarm status of NE
- "Urgent Alarm
- "Non-urgent Alarm
COBU<X>

- Current admissible
- Resistance
- Open contact leakage current @ 75V
- Open contact max. voltage
- Immunity
- Surges
- Voltage (any alarm output lead to earth)

:
:
:
:

< 50 mA
< 50 Ohm
100 A
150 V

to 1.2/50 s surge impulses


with
U = 2000 V
to 0.5A applied for 10 s

1 kV/50 Hz/60 s

:
:

active
not active

:
:

not active
not active

DC power interface
- Interface access
- Power converter units

:
:

FOX subrack *)
POSUM
POSUS

- DC/DC (primary to secondary voltage)


- POSUM @ +/-5 VDC (total)
- POSUS @ +5 VDC

:
:

16 A
10 A

:
:

POSUA
POSUA

16 A

- Current (between the alarm output leads)


- Insulation (any alarm output lead to earth)
Conditions at the alarm outputs in case of
- power fail
- "Urgent Alarm" output
- "Non-urgent Alarm" output
- inactive control unit
- "Urgent Alarm" output
- "Non-urgent Alarm" output

Power interfaces

AC power interface (FOX512 only)


- Interface access
- Power converter unit
- DC/DC (primary to secondary voltage)
- POSUA @ +/-5 VDC (total)

*) For details of the subrack power interfaces, refer to :

1KHW002006

page 44 of 68

FOX515
FOX512
complementary specifications
below

ABB

User Guide FOX515 System Specification (R8)

Common features system specification

EMC/ESD and safety


EMC

Product family standard


Public Telecommunication network equipment

EN 300 386 V1.3.3

Interference voltage 0.15 MHz ... 30 MHz


- DC power supply IF
- AC power supply IF (POSUA)
- traffic signal IFs

:
:
:

EN 55022, class A
EN 55022, class B
EN 55022, class B

Radiated field 30 MHz ... 1000 MHz

EN 55022, class B

IEC/EN 61000-4-3

IEC/EN 61000-4-6

Emission

Immunity
Electromagnetic field
80 MHz ... 2000 MHz, level 3, 10 V/m
Conducted common mode HF disturbance
150 kHz ... 80 MHz,
modulated 1 kHz 80% AM, 3 V
Fast transients/bursts
- on power supply IF (CDN)
- on traffic signal IFs (capacitive clamp)
Surge immunity
- Traffic and control IFs

:
:
:

IEC/EN 61000-4-4
1 kV
0.5 kV

- Power supply interface


- Common mode

:
:

EN 300 386 V1.3.2 and


ITU-T K.20
IEC/EN 61000-4-5
1 kV
1.2/50 s (8/20s)
0.5 kV
1.2/50 s (8/20s)

- Differential mode

Electrostatic Discharge
- contact discharge
- air discharge

:
:
:

IEC/EN 61000-4-2
6 kV
8 kV

Safety according to

IEC/EN 60950-1

ESD

Safety

ABB

page 45 of 68

1KHW002006

Common features system specification

User Guide FOX515 System Specification (R8)

Ambient and dependability


Ambient conditions

Storage
All equipment (exclusive batteries) according to

ETS 300 019-1-1


class 1.2
-25C ... +55C
according to class 1.2
Not specified
According to the specifications of the battery supplier

Temperature range
Humidity
Biological and chemical active substances
Batteries (BATMO option)

:
:
:
:

All equipment (exclusive batteries) according to

ETS 300 019-1-2


class 2.2

Transport

Temperature ranges
- ambient air for unventilated enclosures
- ambient air for ventilated enclosures or outdoor
Humidity
Vibration random Acceleration Spectral Density
- ASD @ 10-200 Hz
- ASD @ 200-2000 Hz
Biological and chemical active substances
Batteries (BATMO option for FOX512)

:
:
:

-25C .. +70C
-25C .. +40C
according to class 2.2

:
:
:
:

1.0 m2s-3
0.3 m2s-3
Not specified
According to the specifications of the battery supplier

All equipment (exclusive batteries) according to

ETS 300 019-1-3


class 3.2

Temperature range system (extended)


- Operation
- without forced ventilation *)
- with forced ventilation
- Start up temperature
Humidity

:
:
:
:

-20C ... +55C


-20C ... +70C
-20C
according to class 3.2
up to 95%, non-condensing

Direct ambient temperature range units (PBUS,


ABUS, SBUS, new UBUS, control, power units)
- Range of operation
- Compliant with specifications

:
:

-20C ... +85C


0C +70C

Biological and chemical active substances

Not specified

Batteries (BATMO option for FOX512)

According to the specifications of the battery supplier

Operation

*) forced ventilation is mandatory for some units

1KHW002006

page 46 of 68

ABB

User Guide FOX515 System Specification (R8)

Common features system specification

Dependability
Availability
Mean accumulated down time (MADT)
traffic between any two 2 Mbit/s ports of 2 NEs

< 10 min. per year


(excluding failures of the
transmission media)

Calculated MTTF for all categories of failures


- Single unit
- Detailed MTTF figures per unit
Predictions based on

:
:
:

> 20 years
refer to the unit descriptions.
MIL-HD BK-217F

MTTF

MTTF values of operating systems are available on request.

ABB

page 47 of 68

1KHW002006

Common features system specification

1KHW002006

User Guide FOX515 System Specification (R8)

page 48 of 68

ABB

User Guide FOX515 System Specification (R8)

FOX515 (subrack R2) supplementary specifications

FOX515 (subrack R2)


supplementary specifications

Powering
DC interface
Power supply interface according

Voltage range for operation

ETS 300 132-2


interface A
-40 VDC -72 VDC

Power consumption
- Maximum continuous current
- Maximum admissible power consumption

:
:

30 A
1200 Watt

Recommended fusing

max. 30 A slow blow

Connection points for power supply circuits


- External supply circuit(s)

1 interface or 2 interfaces (for


dual power supply)
on the cable tray

- Subrack power interfaces


- Single power supply
- Dual power supply

:
:

1 interface
2 interfaces (DUPI4 option)

DC/DC power conversion

POSUM
POSUS

Operation of power supply units


- Parallel operation of units
- Number of units operating in parallel

:
:

load sharing
5

Protection and load sharing


- Protection type
- Life insertion of converter units

:
:

n + 1 (n = 0 ... 4)
yes

Internal power supply

Conversion

Protection

ABB

page 49 of 68

1KHW002006

FOX515 (subrack R2) supplementary specifications

User Guide FOX515 System Specification (R8)

Power dissipation
Maximum power dissipation
Maximum admissible power dissipation PD in
the FOX subrack (for ambient conditions)
- Natural air convection
(evenly distributed units in the subrack)
- Forced ventilation/air conditioning
- Range (with FANU5)
- Ventilation mandatory

depending on traffic interfaces

PD 150 W totally and


PD < 11 W in any slot

:
:

PD 1200 W totally
PD > 150 W totally or
PD 11 W in any slot
provided that specified ambient conditions are fully met *)

- Fan unit for FOX515

FANU5

*) forced ventilation is mandatory for some units

1KHW002006

page 50 of 68

ABB

User Guide FOX515 System Specification (R8)

FOX515 (subrack R2) supplementary specifications

Subracks
FOX515

Construction
Card cage for FOX units
Modularity

:
:

19-inch practice
subrack
cable tray
heat deflection shield
fan unit

Installation into racks


- 19 inch
- ETSI (applicable standard ETS 300 119-4)

:
:

direct
with adapters

Basic construction
- Sides and rear
- Top and bottom
- Front

:
:
:
:

metallic
sheet metal
perforated sheet metal
front cover

Connection of power supply


- Connection principle
- Supply modes

:
:

- Support of dual power supply

integrated connector(s)
single and dual power supply
supported
DUPI4 option
mechanically and electrically
integrated in the FOX515
subrack

Connection of signal cables


- Shields of signal cables
- Cable installation and strain relief

:
:

grounding bars in front


matching cable tray

Slots
- Number of slots
- Slot width

:
:

21
20.32 mm
4 TE

Segmentation of access
- ABUS
- PBUS
- SBUS
- UBUS

:
:
:
:

14 slots (2 sectors)
20 slots
14 slots (2 sectors)
21 slots

Allocation of units to slots

flexible
slot 11 dedicated

Unit construction

19-inch practice
1 HU (44.45 mm)

Capacity and slots

FANU5 fan unit


Construction

ABB

page 51 of 68

1KHW002006

FOX515 (subrack R2) supplementary specifications

User Guide FOX515 System Specification (R8)

Installation into racks


- 19-inch
- ETSI (applicable standard ETS 300 119-4)

:
:

direct
with adapters

Connection of signal and power cable

front access

Number of fans

10

Operation
Temperature control of the fan speed
- minimum speed
- maximum speed

temperature controlled

:
:

20 C
35 C

Performance, average
- minimum speed (free blowing)
- air velocity
- transported air volume
- pressure drop
- noise

:
:
:
:

1 m/s
3
350 m /h
25 Pa
53 dBA @ 1 m

- maximum speed (free blowing)


- air velocity
- transported air volume
- pressure drop
- noise

:
:
:
:

2 m/s
3
600 m /h
80 Pa
66 dBA @ 1 m

Types
- Optical indicators:
- Unit powered
- Partial unit failure
- Total unit failure

:
:
:

1 green LED
1 yellow LED
1 red LED

- Electrical contacts:
- Type
- Current
- Voltage drop @ 10 mA
- Open contact maximum voltage

:
:
:
:
:

solid state
10 mA
2V
-75 V
protected against reverse polarity
100 A

Connector

Molex Mini-Fit Jr.

Voltage range
- nominal
- range
- switch on voltage (power up)
- switch off voltage (power down)
- resistance to reverse polarity

:
:
:
:
:

-48 VDC
-39.5 VDC -75 VDC
-35 VDC
-27 VDC
+75 VDC

Power consumption (-48 VDC battery)


- minimum speed (all fans operating, T < 20 C)
- maximum speed (all fans operating, T > 35 C)

:
:

0.6 A
1.2 A

Connector

Molex Mini-Fit Jr.

Specification

Alarm interface

- Leakage current @ -75 V

Power supply

1KHW002006

page 52 of 68

ABB

User Guide FOX515 System Specification (R8)

FOX515 (subrack R2) supplementary specifications

Ambient conditions
according to common features system specification, except
Operation
Temperature range
Minimum start up temperature
Humidity

:
:
:

-10C ... +70C


-25C
up to 95%, non-condensing

Overall dimensions (W x H x D)
Construction
Weight FANU5 without packaging
Weight FANU5 power cable
Weight ETSI adapters 1 HU

:
:
:
:
:

482.6 x 43.6 x 248.6 mm


19 inch and ETSI mounting
2.79 kg
0.06 kg
0.05 kg

- MTTF for partial unit failure


- MTTF for total unit failure

:
:

> 5 years
> 1000 years

Power inputs

U1
U2

Power output to FOX

UTF

Alarm outputs

Supervision U1
Supervision U2

Input voltage range

-39.5 ... -75 VDC

Maximum reverse polarity

+75 VDC

Maximum output current

30 A

Typical power dissipation at maximum current

10 W

Mechanical parameters

Reliability
MTTF @ 35C ambient temperature

DUPI4 dual supply input


Interfaces

Specifications

ABB

page 53 of 68

1KHW002006

FOX515 (subrack R2) supplementary specifications

User Guide FOX515 System Specification (R8)

Alarm interface
Alarm threshold voltage

-33 3 VDC

Electrical contacts:
- Type
- Current
- Voltage drop @ 10 mA
- Open contact maximum voltage
- Leakage current @ -75 V

:
:
:
:
:

solid state
10 mA
2V
-75 V
100 A

Connector

Molex Mini-Fit Jr.

Installation

Mechanically integrated in
FOX515 subrack

Overall dimensions (W x H x D)

438 x 31.7 x 52.6 mm

Weight without packaging

0.41 kg

MTTF @ 35C

1610 years

Mechanical parameters

Reliability

1KHW002006

page 54 of 68

ABB

User Guide FOX515 System Specification (R8)

FOX515 (subrack R2) supplementary specifications

Dimensions and weight


Dimensions
19-inch subrack without front cover (W x H x D)
19-inch subrack with front cover (W x H x D)
Cable tray (W x H x D)
Heat deflection shield (W x H x D)

:
:
:
:

482.6 x 309.5 x 280.4 mm


482.6 x 309.5 x 284.1 mm
482.6 x 87.1 x 240.2 mm
482.6 x 87.8 x 228 mm

Construction and layout

19-inch and ETSI mounting


practice

Weight

ABB

19-inch subrack (without units) without front cover :


Front cover
:

6..81 kg
1.13 kg

Cable tray
Power cable with WAGO connector block

:
:

0.53 kg
0.08 kg

Heat deflection shield

1.27 kg

ETSI adapters (set)


- 2 HU
- 8 HU
- 9 HU
- 10 HU
- 11 HU

:
:
:
:
:

0.09 kg
0.36 kg
0.41 kg
0.45 kg
0.49 kg

Weight of options (FANU5, DUPI4)


Weight of units

:
:

refer to option specification


refer to unit descriptions

page 55 of 68

1KHW002006

FOX515 (subrack R2) supplementary specifications

User Guide FOX515 System Specification (R8)

Installation
Subrack, cable tray
Construction and installation
Height of subrack and cable tray
Installation into ETSI racks
Torques
- 19-inch / ETSI equipment and adapters M6 (4.8)
- DUPI4 unit
- Grounding/bonding terminal
- Unit front covers M2.5

:
:
:

19-inch practice
8 HU (= 355.6 mm)
with adapters

:
:
:
:

max. 4.7 Nm
max. 0.34 Nm
max. 2.0 Nm
max. 0.56 Nm

Traffic signals (new FOX units)

:
:
:
:
:

DIN 41 612
32 pins, rows a, c (b)
unit
proprietary
where applicable
yes
grounding bar, cable tray

Connection of signals

Male connector
Connector cover
Coding keys
Latching system
Strain relief

Traffic signals (old FOX units)


Management interfaces (control unit)
- F-interface
- QX-interface

refer to FOX-U description

:
:

- Q1-interface

- Strain relief

SUBMINI D, 9 p./f.
10BASE-T (RJ-45)
half-duplex
DIN 41 612
8 pins, rows a, c
latching system
grounding bar, cable tray

Auxiliary signals (control unit)


- Synchronisation inputs/outputs

- Alarm inputs/outputs

- Latching system and coding keys


- Strain relief

:
:

DIN 41 612
8 pins, rows a, c
DIN 41 612
8 pins, rows a, c
yes
grounding bar, cable tray

EMC protection of signal interfaces


- Signal cables with shields
- Signal cables without shields

:
:

grounding bar of subrack


toroidal core ferrite

Mechanical shock and vibration

ETS 300 019-1-3

Subrack (internal access for power supply)


- Number of power interfaces

- Connector type

1 standard
2 with DUPI4 option
4 pin FAST-ON type connector

Cable tray (external access for power supply)


- Number of power interfaces

Connection of power supply

1KHW002006

page 56 of 68

ABB

User Guide FOX515 System Specification (R8)

FOX515 (subrack R2) supplementary specifications

- Connection

Power cables (subrack connector WAGO block)


- Cable provisioning
:
- Cross section per cable section

ABB

page 57 of 68

2 with DUPI4 option


4 pin WAGO connector
block(s)
1 cable provided with
- subrack
- DUPI4 option
2
5 mm

1KHW002006

FOX515 (subrack R2) supplementary specifications

1KHW002006

page 58 of 68

User Guide FOX515 System Specification (R8)

ABB

User Guide FOX515 System Specification (R8)

FOX512 (subrack R2) supplementary specifications

FOX512 (subrack R2)


supplementary specifications

Powering
DC interface
Power supply interface according

ETS 300 132-2


interface A

Interface access

subrack

Nominal input voltages (POSUM/POSUS)


- -48 VDC, voltage range
- -60 VDC, voltage range

:
:

-40.5 VDC -57 VDC


-50.5 VDC -72 VDC

Maximum continuous input current


Recommended fusing

:
:

10.0 A
10 A slow blow

Connection points for power supply circuits


- Standard

- Protected

1
on the cable tray
2
with DUPOS

Power supply interface according

ETS 300 132-1


interface A

Interface access

POSUA

Nominal input voltages


- 115 VAC, voltage range
max. 90 % of rated power
- 230 VAC, voltage range
max. 90 % of rated power

:
:
:
:

88 VAC 132 VAC


88 VAC 99 VAC
176 VAC 264 VAC
176 VAC 198 VAC

Frequency

45 Hz 63 Hz

Operation of POSUA from DC power sources

not possible

Max. converted power (internal -48 VDC rail)


- Nominal power @ 115/230 VAC
- 88 99 VAC / 176 198 VAC

:
:

140 W
126 W

AC interface

ABB

page 59 of 68

1KHW002006

FOX512 (subrack R2) supplementary specifications

User Guide FOX515 System Specification (R8)

Max. current (internal -48 VDC rail)

2.8 A

Maximum continuous input current


- 115 VAC
- 230 VAC

:
:

< 2.0 A
< 1.0 A

Interface access

POSUA

Charger interface
- nominal voltage @ 20C
- temperature compensation

:
:

-54.8 VDC
+110 mV/C

Max. power drain from battery

3A

Protection of the battery from excessive


discharging
- Switch OFF for battery drain
- Switch ON for battery drain

:
:
:

via FET switch (POSUA)


UTF = -42 VDC 1.5 VDC
after mains restart

Interface protection BATMO side


- Protection via
- Time to high impedance

:
:

self-healing PTC fuse


< 60 ms

Max. cable length between POSUA and BATMO

3 m / 3 x 1.5 mm

Maximum admissible power consumption


- DC power interface
- Mains power interface

:
:

320 W
180 W

DC/DC (primary to secondary voltage)

POSUM
POSUS
POSUA

AC/DC (mains to primary voltage)

POSUA

DC/DC conversion with the POSUM/POSUS


- unit protection
- load sharing
- life insertion of converter units

:
:
:

1+1
yes
yes

AC/DC conversion with the POSUA


- unit protection
- protection of the AC/DC conversion

:
:

no
no (only 1 unit)
protection of primary voltage

DC battery backup interface

Power consumption

Internal power supply


Conversion

Protection

1KHW002006

page 60 of 68

ABB

User Guide FOX515 System Specification (R8)

FOX512 (subrack R2) supplementary specifications

- load sharing
- life insertion of converter units

:
:

via battery backup


not applicable
no

DC/DC conversion with the POSUA


- protection of DC/DC conversion
- load sharing
- life insertion of
- POSUM/POSUS
- POSUA

:
:

with POSUM/POSUS
yes with POSUM/POSUS

:
:

yes
no

Concurrent power supply of the FOX512 via


mains (POSUA) and the
- BATMO battery backup
- DC power supply terminal of the subrack

:
:

yes
not possible

Maximum power dissipation

depending on traffic interfaces and installation

Maximum admissible power dissipation


- Natural air convection (for specified ambient)

PD 60 W totally and
PD < 11 W in any slot

- Forced ventilation or air conditioning


Mandatory for PD range

60 W < PD < 320 W totally or


11 W < PD < 40 W in any slot

Power dissipation

Vertical installation

provided specified ambient


conditions are fully met *)

Horizontal installation
Maximum admissible power dissipation
- Natural air convection (for specified ambient)
- Forced ventilation with FANU2 (R2) fan unit

:
:

not admitted
PD 320 W

provided specified ambient conditions are fully met *)


*) forced ventilation is mandatory for some units

ABB

page 61 of 68

1KHW002006

FOX512 (subrack R2) supplementary specifications

User Guide FOX515 System Specification (R8)

Subracks
FOX512

Construction
Card cage for FOX units
Modularity

:
:

proprietary subrack
versatile subrack with
- 19-inch adapter
- ETSI adapters
- wall-mounting adapter

Installation into racks


- 19-inch
- ETSI (applicable standard ETS 300 119-4)

:
:

with adapter
19-inch with adapters

Installation on walls and in cabinets

with adapter

Basic construction
- Sides and rear
- Top and bottom
- Front
Connection of signal and power cables
- Power supply (DC)
- Shields of signal cables
- Cable installation and strain relief

:
:
:
:

metallic
sheet metal
perforated sheet metal
front cover

:
:
:

integrated connector
grounding bars in front
installation adapters with
cable tray

Slots
- Number of slots

- Slot width (standard slots)

8 standard
1 special for fan unit
20.32 mm
4 TE

Segmentation of access
- ABUS
- PBUS
- SBUS
- UBUS

:
:
:
:

5 slots
7 slots (incl. slot 11)
5 slots
8 slots (incl. slot 11)

Allocation of units to slots

flexible
slot 11 dedicated

Unit construction

proprietary for the FOX512


subrack

Installation

in slot 1of the subrack

Connection of signals and power

all internal connections

Capacity and slots

FANU2 (R2) fan unit


Construction

Specification

1KHW002006

page 62 of 68

ABB

User Guide FOX515 System Specification (R8)

FOX512 (subrack R2) supplementary specifications

Number of fans

Operation

temperature controlled
- low speed
- high speed

Temperature control of the fan speed


- low speed
- high. speed

:
:

< 27 C
> 45 C

Performance (average)
- low speed (free blowing)
- air velocity
- transported air volume
- noise

:
:
:

1 m/s
3
70 m /s
46 dBA @ 1 m

- high speed (free blowing)


- air velocity
- transported air volume
- noise

:
:
:

2 m/s
3
120 m /s
56 dBA @ 1 m

Types
- Optical indicator
- Local failure indicator
- Failure and alarm indication

:
:

1 red LED
integrated with the FOX
alarm system

- Electrical contacts
- Local contacts
- Failure and alarm indication

:
:

none
integrated with the FOX
alarm system

Connection to the COBU<X>

all internal connections

Supply circuit

-48 VDC
(internal power rail)

Power consumption (-48 VDC rail, typical)


- low speed (both fans operating, T = 27 C)
- high speed (both fans operating, T > 45 C)

:
:

< 120 mA
< 250 mA

Connection of power supply

all internal connections

Alarm interface

Power supply

ABB

page 63 of 68

1KHW002006

FOX512 (subrack R2) supplementary specifications

User Guide FOX515 System Specification (R8)

Reliability
MTTF @ 35 C ambient temperature
- MTTF for partial failure
- MTTF for total unit failure

:
:

> 50 years
> 1000 years

Connection of power supply, alarm signals

all internal connections

Basic construction
- Sides
- Rear
- Top and bottom
- Front
Battery power cable

:
:
:
:
:
:

Proprietary metal case


sheet metal
open
sheet metal
front cover
3-pin WAGO plug

Number of batteries (12 VDC) required

4 (48 VDC)

Battery type

- Nominal voltage
- Nominal capacity
Mechanical parameters:
- Dimensions max. (W x H x D)
- Weight
- Cable terminals
Recommended commercial grade batteries

:
:

maintenance-free
lead batteries
12 VDC
17 Ah

BATMO battery package


Battery case

Batteries

Expected lifetime for


- 20 % loss of capacity
- operation at 20 C
Performance vs. temperature
- Operation (with reduced performance)
- Temperature range for correct charging
- Reduction of the battery capacity by
- 20 % at
- 50 % at

:
:
:
:

77 x 168 x 183 mm
ca. 6.5 kg
bolts and nuts M5
YUASA NP17-12I
Panasonic LC-RD1217P
or equivalent products

up to 4 years

:
:

-10 C + 55 C
-10 C + 40 C

:
:

0 C
-20 C

Other battery types might have different parameter specifications.

1KHW002006

page 64 of 68

ABB

User Guide FOX515 System Specification (R8)

FOX512 (subrack R2) supplementary specifications

Dimensions and weight


Dimensions
Subrack without front cover (W x H x D)
Subrack with 19-inch adapter (horizontal view)
- without front cover (W x H x D)
- with front cover (W x H x D)
Subrack with ETSI adapters (horizontal view)
- without front cover (W x H x D)
- with front cover (W x H x D)

177.0 x 458.8 x 279.7 mm

:
:

482.6 x 177.0 x 279.7 mm


482.6 x 177.0 x 283 mm

:
:

532.6 x 177.0 x 279.7 mm


532.6 x 177.0 x 283 mm

Subrack with wall-mounting adapter


- without front cover (W x H x D)
- with front cover (W x H x D)

:
:

177.0 x 510 x 286.2 mm


177.0 x 510 x 289.5 mm

Construction and layout

proprietary, adaptable for 19inch and ETSI mounting


practice
(refer to figures)

BATMO battery package


- without rear flanges ( W x H x D)
- with flanges ( W x H x D)

:
:

188 x 425 x 206 mm


227 x 425 x 206 mm

Subrack (without units, FANU2)


- with front cover
- without front cover

:
:

4.71 kg
4.07 kg

Subrack with front cover (without units)


- with 19-inch adapter
- with ETSI adapters
- with wall-mounting adapter

:
:
:

4.89 kg
5.06 kg
5.67 kg

FANU2 fan unit


Dummy cover for FANU2 slot
Dust filter unit

:
:
:

0.64 kg
0.07 kg
0.11 kg

Weight of units
BATMO battery package
- case without batteries
- case with batteries

refer to unit descriptions

:
:

4.2 kg
ca. 32 kg

Weight

ABB

page 65 of 68

1KHW002006

FOX512 (subrack R2) supplementary specifications

User Guide FOX515 System Specification (R8)

Installation
Subrack, cable tray
Construction and installation

proprietary with installation


adapters for
horizontal and vertical installation

Width (horizontal height) of subrack

4 HU (= 177 mm)

Installation
- in 19-inch racks (horizontal, vertical)
- in ETSI racks (horizontal, vertical)
- on walls or in cabinets (vertical)

:
:
:

with adapter
with adapters
with adapter

Cable tray

19-inch adapter
wall-mounting adapter

Torques
- 19-inch / ETSI equipment and adapters M6 (4.8) :
- Angle bracket M4 (4.8)
:
- Unit front covers M2.5
:

max. 4.7 Nm
max. 1.3 Nm
max. 0.56 Nm

Installation
- wall- and cabinet-mounting
- ground installation

:
:

via screws or similar.


stand alone on the ground

Traffic signals (new FOX units)

:
:
:
:
:

DIN 41 612
32 pins, rows a, c (b)
unit
proprietary
where applicable
yes
grounding bar, cable tray

Traffic signals (old FOX units)

refer to FOX-U description

Management interfaces (control unit)


- F-interface
- QX-interface

:
:

- Q1-interface

- Strain relief
Auxiliary signals (control unit)
- Synchronisation inputs/outputs

SUBMINI D, 9 p./f.
10BASE-T (RJ-45)
half-duplex
DIN 41 612
8 pins, rows a, c
latching system
grounding bar, cable tray

- Alarm inputs/outputs

BATMO battery package

Connection of signals

1KHW002006

Male connector
Connector cover
Coding keys
Latching system
Strain relief

page 66 of 68

DIN 41 612
8 pins, rows a, c
DIN 41 612

ABB

User Guide FOX515 System Specification (R8)

FOX512 (subrack R2) supplementary specifications

- Latching system and coding keys


- Strain relief

:
:

8 pins, rows a, c
yes
grounding bar, cable tray

EMC protection of signal interfaces


- Signal cables with shields
- Signal cables without shields

:
:

grounding bar of subrack


toroidal core ferrite

Mechanical shock and vibration

ETS 300 019-1-3

Subrack (internal access for power supply)

Cable tray (external access for power supply)


Mains

:
:

3-pin FAST-ON type connection


(cable provided with subrack)
3-pin WAGO connector block
POSUA front
3-pin apparatus plug

Interface for the external backup battery

Connection of power supply

ABB

page 67 of 68

POSUA front
3-pin WAGO plug

1KHW002006

For more information please contact:


ABB Switzerland Ltd
Power Systems
Utility Communications
Bruggerstrasse 72
5400 Baden
Switzerland
Phone: +41 58 589 37 35
or: +41 844 845 845 (Call Center)
Fax: +41 58 585 16 82
E-Mail: utility.communication@ch.abb.com
www.abb.com/utilitycommunications

You might also like