Abb Fox System Specifications r8 RF 1khw002006
Abb Fox System Specifications r8 RF 1khw002006
Abb Fox System Specifications r8 RF 1khw002006
FOX515
FOX System Specification
User Manual
User Guide
FOX515 System Specification
Platform FOX515 Release R8
Release History:
Release 7B:
Release 8B:
Release 8C:
February 2007
Dezember 2008
August 2009
Dezember 2009
May 2010
Disclaimer:
Document number:
1KHW002006
ABB Ltd
Power Systems
Bruggerstrasse 72
5400 Baden Switzerland
ABB Switzerland Ltd, 2010
The right to modifications or deviations due to technical progress is reserved.
1KHW002006
page 2 of 68
ABB
Table of contents
1
General
ABB
9
9
Traffic functions
ATM traffic
IMA
CES
PDH traffic
SDH traffic
Ethernet over SDH Ethernet switching
Ethernet over SDH
Ethernet switching
Ethernet LAN to TDM WAN bridging
Power over Ethernet provisioning (PoE)
V5 functions
NGN Access Gateway
ADSL and SHDSL based broadband access aggregation
Conference functions
Protection
Monitoring of traffic signals
Diagnostic functions
11
11
11
12
12
13
14
15
15
16
16
17
17
18
20
21
21
22
Synchronisation
General
PETS
SETS
Maintenance and Diagnostics
Fault management
SSM and QL processing
23
23
23
23
25
25
26
27
27
27
28
29
29
29
29
30
Architecture
System
ABUS
31
31
32
page 3 of 68
1KHW002006
SBUS
PBUS
UBUS
32
32
32
Management communication
Element Manager
Management communication structures
Routing functions
34
34
34
35
37
37
37
37
38
38
39
39
39
39
39
Interfaces
Traffic interfaces
Synchronisation interfaces
Management interfaces
Alarm interfaces
Power interfaces
41
41
41
42
43
44
45
45
45
45
46
46
47
2
FOX515 (subrack R2) supplementary
specifications
1KHW002006
49
Powering
DC interface
Internal power supply
Power dissipation
49
49
49
50
Subracks
FOX515
FANU5 fan unit
DUPI4 dual supply input
51
49
51
53
55
55
55
page 4 of 68
ABB
Installation
Subrack, cable tray
Connection of signals
Connection of power supply
56
56
56
56
3
FOX512 (subrack R2) supplementary
specifications
ABB
59
Powering
DC interface
AC interface
DC battery backup interface
Power consumption
Internal power supply
Power dissipation
59
59
59
60
60
60
61
Subracks
FOX512
FANU2 (R2) fan unit
BATMO battery package
62
60
62
64
65
65
65
Installation
Subrack, cable tray
BATMO battery package
Connection of signals
Connection of power supply
66
66
66
66
67
page 5 of 68
1KHW002006
Referenced documents
1KHW002006
1KHW002000
1KHW002070
page 6 of 68
ABB
Technical support
ABB Technical Support is available as follows:
ABB
Phone:
+41 58 589 37 35
or:
Fax:
+41 58 585 16 82
E-Mail:
utility.communication@ch.abb.com
URL:
www.abb.com/utilitycommunications
page 7 of 68
1KHW002006
1KHW002006
page 8 of 68
ABB
General
System application
- Multiservice access
- Access multiplexing
- Multiplexing/demultiplexing
V5.1, V5.2
protocol and user ports
H.248 / RTP (POTS)
SIGTRAN (ISDN-BA)
H.248 / MEGACO
(Set up / release control)
ADSL, ADSL2(+) line IF
SHDSL, SHDSL.bis line IF
ATM Ethernet IWF
Voice over IP
Broadband
- video multicast
- IP services
Gbit-Ethernet uplinks
P0-nc (n = 1 ... 31)
P12s / P12x (structured and
unstructured)
STM-1
STM-4
P12x and P0-nc
DXC 1/1 and 1/0
VC-4, VC-3, VC-12
ATM cells
IP packets
MAC frames
PoE class 1 3
and manual power set
ABB
- Cross connecting
- Routing
Bridging
- Power provisioning over Ethernet (PoE)
:
:
:
page 9 of 68
1KHW002006
1KHW002006
- Transmission
Commissioning
- Traffic interfaces
- Traffic functions
- Functions
:
:
page 10 of 68
ABB
Traffic functions
ATM traffic
ATM traffic signals
- Cell format
- Service categories
:
:
UNI
CBR-rt (CBR.1)
CBR-nrt (CBR.1)
VBR-nrt (VBR.1)
UBR
- Services
- VP aggregating
- Interface (port)
- Oversubscription (egress traffic)
:
:
UNI (ATIOP)
1 100
- Cross connection
- Type
- Connections
:
:
PVCs
bi-directional
asymmetric
up 2048 VPC/VCCs
- Number
STM-1 interface
- Termination
- Multiplex Section Protection
:
:
physical section
with ATIOP
ADSL (DMT)
G.SHDSL
data services
PSTN user ports
ISDN user ports
IMA implementation
- Function unit
- Application
:
:
IMA
ABB
page 11 of 68
:
:
ACONV
provisioning of ATM cells via
P12 circuits according to
PHY-0086.001 (V.1.1)
up to 14 per unit
service classes CBR-rt, CBRnrt, VBR-nrt, UBR
1KHW002006
- IMA groups 2 14
- IMA group parameters (settable per interface)
- P12 links per group
up to 16
minimum required links per
group
Symmetrical configuration
and operation
100 ms
:
:
CTC
CTC and ITC
- Scrambling function
activated
- Maintenance functions
- Performance monitoring
IMA group
Link group
loop back
cell counters
CES implementation
- Function unit
- Application
:
:
:
:
:
:
- Maintenance functions
- Performance monitoring
8 Mbit/s signals
- Termination
- Protection 8 Mbit/s
:
:
- Multiplexing/demultiplexing from/into
2 Mbit/s signals
- Termination
- Protection 2 Mbit/s
:
:
- Adaptation
CES
ACONV
provisioning of
P12 circuits via ATM UNI
according to
AF-VTOA-0078.00 V2.0
up to 16 per unit
settable per service
2048 kbit/s (unstructured)
all functions of the FOX P12
traffic signal layer for
P0, P0-nc and P12x
synchronous (PBUS)
Adaptive
SRTS
all functions of the FOX P12
traffic signal layer
all functions of the FOX P12
traffic signal layer
PDH traffic
1KHW002006
page 12 of 68
ABB
- Cross connection
- Special functionalities
:
:
unstructured signals
structured, synchronous signals
structured and unstructured
V5.x
PRA
NT1-PRA
NT1-LL
physical section
:
:
:
n x 64 kbit/s
0 600 kbit/s
DXC 1/0
Subrate multiplexing
- Synchronous
- Asynchronous
- Transparent
data interfaces
(n x 64 kbit/s, n = 1 32)
and subrates 0.33...56 kbit/s)
PSTN interfaces
PSTN user ports
ISDN-PRA
- Termination
:
:
:
:
STM-4 according to
ITU-T G.707
for VC-12, VC-3 and VC-4
STM-1 according to
ITU-T G.707
for VC-12 and VC-3
VC-4 locally
VC-3 locally
VC-12 locally and remote
VC-12 and VC-3
VC-12, VC-3 and VC-4
VC-12, VC-3 and VC-4
Linear trail protection
SNCP
SNCP
SDH traffic
ABB
page 13 of 68
physical section
(optical and electrical)
with SYN4E or with SYNIO or
with 2 SYNUF
1KHW002006
:
:
P12
E12
E31/32
STM-1 (electrical or optical)
- SDH
- Ethernet
-electrical
- optical
10BASE-T / 100BASE-TX /
1000BASE-T
100BASE-FX
1000BASE-LX / SX
1KHW002006
Implementation
- Function unit
- Basic functions
- Physical interfaces
- Number of interfaces
- Interface types
:
:
up to 6
10BASE-T
100BASE-TX / 100BASE-FX
1000BASE-LX / SX
Transport (EoS)
- EoS
- Encapsulation procedure
- Link protection
encapsulation of Ethernet
traffic for the transport via
SDH (VC-12, VC-3)
GFP framing according to
G.7041 (frame mapped)
VC-12 / VC-3 level
according to G.707
Protocol or fixed mode according to ITU-T G.7042
SNCP/N (VC-12 / VC-3)
Ethernet switching
- Switching points
- VLAN support
- Maintenance functions
Physical layer
Transport layer
VC-12, VC-3 layer
- Performance monitoring
- Ethernet PHY MIB-2, RMON
- GFP encapsulation
- VC-12, VC-3
:
:
:
page 14 of 68
NEBRO
NEBRA
Transport (EoS)
Switching (Ethernet traffic)
ABB
SYN4E
- Basic functions
Transport (EoS)
- Physical interfaces
- Number of interfaces
- Interface types
:
:
4
10BASE-T, 100BASE-TX,
1000BASE-T
Transport (EoS)
- EoS
- Encapsulation procedure
- Link protection
encapsulation of Ethernet
traffic for the transport via
SDH (VC-12, VC-3, VC-4)
GFP framing according to
G.7041 (frame mapped)
VC-12 / VC-3 / VC-4 level
according to G.707
Protocol or fixed mode according to ITU-T G.7042
SNCP/N (VC-12 / VC-3 /
VC-4)
- Maintenance functions
Physical layer
Transport layer
VC-12, VC-3, VC-4 layer
- Performance monitoring
- Ethernet PHY MIB-2, RMON
- GFP encapsulation
- VC-12, VC-3, VC-4
:
:
:
Implementation
- Function unit
NEBRE, SWITE
Ethernet switching
ABB
- Basic functions
- Physical interfaces
- Number of interfaces
- Interface types
:
:
up to 6
10BASE-T
100BASE-TX / 100BASE-FX
1000BASE-LX / SX
Ethernet switching
- Switching points
up to 128
- VLAN support
- Maintenance functions
- Performance monitoring
- Ethernet PHY MIB-2, RMON
Physical layer
page 15 of 68
1KHW002006
ETER1
:
:
up to 4
10BASE-TX half/full duplex
100BASE-TX half/full duplex
Access / Trunk
flow control
up to 64
PPP / HDLC encapsulation
and framing
Multilink PPP
Access / Trunk
:
:
Ethernet bridging
- Bridge instances
up to 8 logically independent
instances
- VLAN support
- Maintenance functions
- Performance monitoring
- Ethernet PHY MIB-2, RSTP
Unfiltered events
Physical layer
:
:
Implementation
- Function unit
SWITE
- Interfaces
6 access ports
10BASE-T/100BASE-TX
automatic according to
IEEE 802.3af
Available power
- max. power per SWITE board
- max. power per SWITE interface
- supported IEEE 802.3af power classes
:
:
:
63W
27W (manual power set)
class 1, with up to 4W
class 2, with up to 7W
class 3, with up to 15.4W
IP traffic
1KHW002006
page 16 of 68
ABB
IP traffic signals
- Multiplexing/demultiplexing from/into
- Routing functions
:
:
- Bridging functions
:
:
:
:
:
:
PCONV
4
1
2
240
112
:
:
:
:
:
:
:
2 x 2 Mbit/s
PCON2
10
1
8
480
224
selectable for V5
MCAS
:
:
:
:
:
:
8 ISDN BA
8 ISDN BA
IPSMG
:
:
:
TDM <-> IP
RTP
ITU-T G.711, 64 kbit/s
PCM A-law, silent suppression (Appendix II)
P12s traffic
OSPF V2.0
Frame Relay
transparent MAC bridge
port based virtual LAN
star bridge
V5 functions
V5 protocol processing
- Function unit
- V5.1 interfaces
- V5.2 interfaces
- Max. number of V5.2 link accesses
- Capacity of PSTN user ports V5.2
- Capacity of ISDN BA user ports V5.2
incl. processing of p- and f-data
- Integrated IFs G.703 for V5 link access
- Function unit
- V5.1 interfaces
- V5.2 interfaces
- Max. number of V5.2 link accesses
- Capacity of PSTN user ports V5.2
- Capacity of ISDN BA user ports V5.2
incl. processing of p- and f-data
- Access for PSTN user ports
ABB
page 17 of 68
1KHW002006
- Echo cancelling
:
:
:
H.248 messages
H.248 / MEGACO
H.248.1 v1
primary and secondary
:
:
200 ms
- fixed mode
- adaptive mode
200
10000 BHCA
:
:
ITU-T Q.931
SIGTRAN (IUA/SCTP)
- VLAN
- VLAN tagging (control and media path)
- User priority (control and media path)
:
:
IEEE 802.1Q
IEEE 802.1p
:
:
:
:
:
:
:
:
:
:
8 ISDN BA
8 ISDN BA (on request)
:
:
- Gateway functions
- ATM <-> Ethernet Encapsulation
1KHW002006
page 18 of 68
ABB
IPoA
- Layer 2 switching / bridging
- Modes
- Access control
- Learned MAC addresses
- STP support
:
:
:
- VLAN support
- Tagging
:
:
- Port membership
- static
- dynamic
- DHCP
- TV multicast support
- Number of groups
up to 256
- Group memberships
static
dynamic, IGMPv2 snooping
(RFC 2236)
- Scheduling mechanism
:
:
- Access control
- Packet filtering
- Internet access control mechanisms
ABB
:
:
Uplinks
- Electrical interface
- Optical interfaces (IPLM1 only)
:
:
- Link Aggregation
100BASE-TX / 1000BASE-TX
100BASE-FX / 1000BASESX/LX SFP modules
LACP (IEEE 802.3ad)
ADSL access
- ADSL
ITU-T G.992.1
page 19 of 68
1KHW002006
- ADSL2
- ADSL2+
- Line rates
- Individually configurable
- upstream
- downstream
- Capacity
- Modularity
- Clusters
SHDSL access
- G.SHDSL
- G.SHDSL.bis
- Line rates
- Individually configurable
- ITU-T G.991.2
- ITU-T G.991.2 Annex F/G
- Pair bonding (2 pairs)
- Capacity
- Modularity
- Clusters
Management
- Unit and NE integration
:
:
ITU-T G.992.3
ITU-T G.992.5
:
:
:
in steps of 32 kbit/s
up to 1 Mbit/s
up to 24 Mbit/s
:
:
24 ports
up to 144 ports
:
:
ITU-T G.991.2
ITU-T G.991.2 Annex F/G
:
:
:
:
in steps of 8 kbit/s
200 kbit/s 2320 kbit/s
768 kbit/s 5696 kbit/s
SHDSL line according to ITUT G.994.1 Annex B
(for HS mode only)
:
:
24 ports
up to 144 ports
UCST / FOXMAN-UN
SNMP
CLI
(launch via UCST)
- IP DSLAM functionalities
Function unit
- Data type
:
:
:
:
:
:
:
:
:
Function unit
- Data type
:
:
:
:
:
Parameters
- Attenuation of input signal
- Attenuation of output signal
- Noise suppression
:
:
:
:
Conference functions
1KHW002006
page 20 of 68
COBUV
A-law coded voice in P0, incl.
CAS
bit-wise AND of all input signalling
64
21
8
settable per participant
0, 3, 6 and 9 dB
0, 3 dB
selectable
3 steps
NEMSG
A-law coded voice in P0, incl.
CAS
bit-wise AND of all input signalling
32
8
17
settable per participant
0, 3, 6 and 9 dB
0, 3, 6 and 9 dB
selectable
3 steps
ABB
Protection
Section protection
1 SYN4E
1 SYN4E
1 SYNIO
2 SYNUF
2 ATIOP
2 Mbit/s (P12s)
(with PBUS units only)
VC-4, VC-3, VC-12
(on SYN4E)
2 Mbit/s and 64 kbit/s
(P12x, P0 and P0-nc)
(with PBUS units only)
VC-4, VC-3, VC-12
(on SYN4E)
VC-12
VC-3
- ATM
Subnetwork protection for signals
- SNCP/N
:
- SNCP/I
:
:
Equipment protection
- Traffic unit type
- units without front interfaces
:
:
- Unit switch-over
Performance monitoring
Monitoring points
- PDH
ITU-T-G.826
- SDH
- ATM
-STM-1 UNI
- ATM traffic
ACONV
(EQP for SYNAC is a
FUTURE OPTION)
IPSMG
n+1
hot standby
non-revertive
automatic unit failure driven
and
UCST command
unit restart
restart of services
ABB
page 21 of 68
VC-4
RS and MS in STM-1
cell counters
1KHW002006
- Ethernet
- Ethernet PHY
:
:
Function unit
Test purposes
:
:
Diagnostic functions
1KHW002006
page 22 of 68
ABB
Synchronisation
General
Basic configurations
:
:
:
PETS
PETS and SETS
SETS only
(PETS locked to SETS)
Function units
- PETS
- SETS
:
:
COBU<X>
SYNI<X>, SYNUF, SYN4E,
ATIOP
Selection algorithm
- QL based
- Priority based
- Switching
- Configurable Hold off time
- Configurable wait to restore time
:
:
:
:
:
QL 1 ... 15
1 ... 7/8 (1 highest)
revertive
0-60 s
0-720 s
:
:
:
P12s terminated
P12s monitored
P0 signals
:
:
2 (ESI-1 2)
50 ppm
:
:
high Q
low Q
:
:
2.5 Hz
< 0.5 dB
:
:
40 Hz
< 0.5 dB
:
:
3 (ESO-1 3)
- source selected
- QL of NE (1 ... 15)
Equipment protection
Architecture
- NE level
PETS
Timing sources for PETS
- Traffic signals (up to 4)
SETS
ABB
page 23 of 68
1KHW002006
Select A
Select C
Squelch
2 Mbit/s
ESI-1 (T3)
2 MHz
Squelch
SETG
(PLL)
Select B
SETS
Int ernal
1KHW002006
Specification
- Optimised for 2048 kbit/s hierarchy
- Accuracy under free-running conditions
- Minimum pull in range
- Wander generation in locked mode
:
:
:
:
- Wander tolerance
:
:
:
:
:
:
1 Hz
10 Hz
lower than 0.2 dB
Figure 12/G.813
Figure 14/G.813
G.813 10.3
STM-1 MS (T1)
2 Mbit/s terminated (T2)
2 Mbit/s monitored (T2)
1 ESI-1 (T3)
:
:
:
:
:
page 24 of 68
1 ESO-4/SDH (T4)
- SETS locked
- Non SETS locked
- selected source
- QL of NE (1...15)
Figure A.1/ETS 417-6-1
0 to 60s
0 to 720s
ABB
Equipment protection
- SDH (SBUS)
- ATM (ABUS)
Selection
- Auto-selection (SETS Select B/A, PETS):
- Forced free-run
- Forced holdover
:
:
4.12
(QL-enabled mode corresponds
to QL based selection algorithm
QL disabled mode corresponds to Priority based selection algorithm)
Select A fix to Auto-selection
SETS Select B, PETS
SETS Select B (only if HO frequency available)
:
:
:
:
:
4.11.2.2
4.11.2.3
4.11.2.1
4.11.1.1
4.9
Status
- Timing Source
QL
Priority
Available
Failed
Not supervised
locked
free-run
holdover
(not applicable)
- PETS (COBU<X>)
Fault management
ABB
page 25 of 68
1KHW002006
1KHW002006
S1 byte of STM-4/1 MS
Mapping of the QL
- in receive direction
- in transmit direction
page 26 of 68
ABB
:
:
Traffic units
:
:
:
PCMCIA card
(removable)
8, 16 MB
:
:
:
:
:
:
Unit software
- EM controlled SW download (for ESW)
- Control units
- Traffic units
:
:
short interruption
250 s
insertion of one 0-bit corresponding to an interruption of
488 ns
interruption 4 ms
insertion of 1 4 0-bits corresponding to an interruption
of 1952 ns
50 ppm
NE software system
- CPE
ABB
page 27 of 68
COBU<X>
ABUS units
PBUS units
SBUS units
new UBUS units
MUSIC 200 (R4)
Line Runner SHDSL DTM
:
:
1KHW002006
NE incl. ESW
traffic functions
NE
traffic signals
Management functions
1KHW002006
Fault management
- Hardware failures
- ESW configuration/operation
- Failures and performance
Alarm generation and reporting
- Generation and severity
- Indication
:
:
:
NE and units
units and CPE
traffic signals
:
:
- Reporting
programmable
local indicators and relay
contacts
alarm lists
logbook
remote access
Inventory management
UCST R8B
FOXMAN-UN R8B
CLI
(launch via UCST)
page 28 of 68
ABB
:
:
- Inventory data
Functional level
- Diagnostic
- Traffic functions
Functional level
- Synchronisation functions
- System functions
Unit level
- Fault indicators
- Test loops
- State indication:
- Performance monitoring
:
:
:
:
:
COBUX, COBUV
Test signal generator
signal analyser
- Test signal
- Type
Central diagnostics
ABB
- Analyses
- 8-bit pattern
- Pseudo random bit pattern
:
:
- Channel connection
page 29 of 68
matching patterns
performance monitoring
channel delay
via cross connect
1KHW002006
FOX
Remote equipment
Synchronisation
SSI
(P12s signals only)
only if specified
not compatible
FOX-U
FOX-U/M (-U/E)
DSL product family
Backward compatibility
1KHW002006
page 30 of 68
ABB
Architecture
System
System architecture
fully modular
open architecture
Implementation
configurable
according to requirements
- Control units
type COBU<X>
- Subsystems
MIB of the NE
PETS
Processing of Management
Com
Control of BUS access
UBUS access
Diagnostics
Conference functions
COBUX, COBUV
- ECC
COBUX, COBUV
- Conference function
COBUV
- 8 x 2 Mbit/s
COBUX, COBUV
- 4 x 2 Mbit/s
COBUL
-128 x 2 Mbit/s
- 40 x 2 Mbit/s
control units R5
on removable units
Unit types
- Units with ABUS access
ABUS units
PBUS units
SBUS units
UBUS units
Special units
down loaded
System control
- UBUS highways
- PBUS highways
- ATM functionality
Functional levels of equipment protection
- System function level
ABB
page 31 of 68
1KHW002006
Configuration
Capacity
1215000 cells/s
Logical structure
ATM cells
UNI cell format
Physical structure
32 x 19.44 Mbit/s
per sector
linear with pairs of slots interleaved for MSP
- VC-4 terminating
- Through connection
Logical structure
63 x VC-12 (TU-12) or
3 x VC-3 (TU-3)
Physical structure
4 x 8 x 19.44 Mbit/s
per sector
linear with pairs of slots interleaved for MSP
Capacity
128 x 2 Mbit/s
with and without CAS
Logical structure
Physical structure
32 x 16 Mbit/s
non segmented linear
Capacity
8 x 2 Mbit/s
with and without CAS
Logical structure
Physical structure
8 x 4 Mbit/s
segments, non linear
ABUS
SBUS
Capacity
PBUS
UBUS
1KHW002006
page 32 of 68
ABB
ABB
page 33 of 68
1KHW002006
Management communication
Element Manager
Element Manager
UCST R8C
FOXMAN-UN R8C
:
:
:
:
:
:
P12s
P0-nc
P12
:
:
:
:
:
ATM cells
64 kbit/s, 192 kbit/s
576 kbit/s
ATM, IMA
:
:
:
:
CBR (CBR.1)
80.1 (70.8) kbit/s
240.4 (212) kbit/s
720.4 (636) kbit/s
5000 (600) s
1KHW002006
page 34 of 68
:
:
:
RFC 2364
(incl. AAL5 <-> P0-nc PPP
Relay function)
max. 32
64 1984 kbit/s (P0-nc)
16 kbit/s (TS0 in P12s)
ECC over PDH
ECC over ATM
(transport in ATM cells)
:
:
max. 8
192 kbit/s, 576 kbit/s
ABB
:
:
- ECC addressing
EOC
- Application
- Function unit
- Structure
:
:
:
:
:
:
:
:
9600 bit/s
19200 bit/s
LAN (WAN)
- Type
- NE interface
- EM(S) interface
:
:
:
Ethernet 10BASE-T
QX-interface
Ethernet 10BASE-T
Q-BUS
- Structure
local bus
based on RS-485
NE management
- NE interface to EOC
- EM(s) interface to EOC
- Addressing
Bandwidth
- Mixed NEs FOX-U/M (-U/E)/-U and FOX515
- NEs FOX515 only up to
- NE interfaces to Q-BUS
- Q1-slave interface
- Q1-master interface
- Purpose
- Implementation
- Function
- Management access to Q-BUS
- EM(S) direct access
- EM(S) access via Q1-master interface
- Addressing
- Bandwidth
- Mixed NEs FOX and legacy FOX
- NEs FOX only up to
:
:
:
:
9600 bit/s
57600 bit/s
COBUX, COBUV
COBUL
OSPF V2.0 (RFC 2178)
Routing functions
IP routing
- Function unit
- Routing protocol
- Router interfaces
- COBU<X>
- COBUX, COBUV
- COBUX, COBUV
ABB
page 35 of 68
:
:
:
:
F, Q1, QX,
OSI tunnel
ECC over
- PDH
- SDH
- ATM
1KHW002006
1KHW002006
OSI routing
- Function unit
- Routing protocol
- Router interfaces
:
:
:
COBUX, COBUV
IS-IS (level 1)
QX, OSI tunnels
HDLC routing
- Function unit
- Routing protocol
- Router interface
:
:
COBUX, COBUV
COBUL
proprietary
Q1-interface
page 36 of 68
ABB
non-blocking
structured and non structured
signals
:
:
2 Mbit/s
n x 64 kbit/s (n = 1 ... 31)
status monitor UCST
- Control
Broadcasting
2 Mbit/s
n x 64 kbit/s (n = 1 ... 31)
Delay assignment
- Single TS and consecutive TS n x 64 kbit/s
- Non consecutive TS n x 64 kbit/s
:
:
minimum delay
constant delay
min.
max.
14 s
48 s
min.
max.
min.
max.
21 s
380 s
21 s
501 s
min.
max.
min.
max.
21 s
378 s
21 s
499 s
min.
max.
min.
max.
125 s
248 s
125 s
369 s
min.
max.
min.
max.
125 s
246 s
125 s
367 s
typ.
typ.
139 s
583 s
- Constant delay
- Structured signals P12s (PBUS - UBUS)
- Minimum delay
- Constant delay
- Structured signals P12s (UBUS - PBUS))
- Minimum delay
- Constant delay
- Structured signals P12s (UBUS - UBUS)
- Minimum delay
- Constant delay
:
:
:
:
:
:
ABB
page 37 of 68
:
:
1KHW002006
typ.
90 s
- ADM:
- SYN4E STM-4 VC-4 SYN4E STM-4
- SYN4E STM-4 VC-12 SYN4E STM-4
- SYN4E STM-1 VC-4 SYN4E STM-1
- SYN4E STM-1 VC-12 SYN4E STM-1
:
:
:
:
typ.
typ.
typ.
typ.
16 s
47 s
16 s
47 s
- ADM:
- SYNIO <m> IF_1 SYNIO <m> IF_2
typ.
16 s
1KHW002006
page 38 of 68
ABB
:
:
max.
max.
1.125 ms
1.125 ms
MSP
STM-4 SDH
- Restoration time for bidirectional MSP on section
- SYN4E - SYN4E
- typical
:
- maximum
:
25 ms
< 50 ms
STM-1 SDH
- Restoration time for bidirectional MSP on section
- SYN4E - SYN4E
- SYNIO - SYNIO
- SYNUF - SYNUF
- typical
:
- maximum
:
25 ms
< 50 ms
:
:
:
not specified
not specified
not specified
STM-1 ATM
- Restoration time for MSP on section
- ATIOP ATIOP
- ATIOP - other vendor equipment
:
:
< 50 ms
not specified
IMA interface
ATIOP (STM-1) ACONV LOMIF
LOMIF ACONV ATIOP (STM-1)
- Restoration time ATM cells
- 1 link out of 2 fails
- 2 links out of 4 links fail
:
:
typical 8 ms
typical 8 ms
max. depending on
- link delay(s)
-M
- number of links
typically 50 ms
max. depending on
- link delay(s)
-M
- number of links
IMA
ABB
page 39 of 68
1KHW002006
1KHW002006
ACONV
- restoration time
not specified
depending on
- services
- traffic load
IPSMG
- restoration time
not specified
depending on
- services
- traffic load
page 40 of 68
ABB
Interfaces
Traffic interfaces
Implementation
Physical implementation
- Traffic interfaces
- Traffic functions
:
:
traffic units
traffic units and
control units
Released units
specified per NE
refer to release note FOX /
UCST R8C Release Note
FOX / UCST
Function unit
COBU<X>
ESI-1:
- Synchronisation system
- Frequency
- Galvanic isolation from NE and battery
- Impedance
- According ITU-T G.703, section 10
:
:
:
:
:
:
SETS/PETS
2048 kHz
yes
configurable
75 or
120 (R2A)
| Zin | 3 k
:
:
:
:
PETS
2048 kHz
yes
configurable
:
:
75
| Zin | 3 k
1.2/50 s impulses
U = 100 V
1 kV/50 Hz/60 s
Specification
Units implemented
Synchronisation interfaces
Inputs
- High impedance
ESI-2:
- Synchronisation system
- Frequency
- Galvanic isolation from NE and battery
- Impedance
- Impedance
- According ITU-T G.703, section 10
- High impedance
ABB
page 41 of 68
1KHW002006
- ECLK2MGUARD<X> to earth
1 kV/50 Hz/60 s
ESO-1:
- Synchronisation system
- Frequency
- Galvanic isolation from NE and battery
- Impedance according ITU-T G.703, section 10
:
:
:
:
PETS
2048 kHz
yes (R2A)
75
:
:
:
:
PETS
2048 kHz
no
75
ESO-4:
- Synchronisation system
- Frequency
- Galvanic isolation from NE and battery
- Impedance according ITU-T G.703, section 10
:
:
:
:
SETS
2048 kHz
yes (R2A)
75
120 (R2A)
1.2/50 s impulses
U = 100 V
:
:
:
:
(R2A)
1 kV/50 Hz/60 s
1 kV/50 Hz/60 s
no galvanic separation
F-interface
- Application Layer
- Transport Layer
- Network Layer
- Data Link Layer
- Physical Layer
:
:
:
:
:
proprietary layer 7
TCP
IP
PPP
RS-232
Q1-interface
- Application Layer
- Transport Layer
- Network Layer
- Data Link Layer
- Physical Layer
:
:
:
:
:
proprietary layer 7
TCP
IP
PPP
RS-485
QX-interface
- Application Layer
- Transport Layer
- Network Layer
- Data Link Layer
- Physical Layer
:
:
:
:
:
proprietary layer 7
TCP
IP
IEEE 802.3 Ethernet
10BASE-T
half-duplex
Outputs
Management interfaces
EMS and FOX
1KHW002006
page 42 of 68
ABB
Virtual LAN
via COBU<X>
Q1-master interface
- Application
- Physical Layer
:
:
:
:
Function unit
COBU<X>
Alarm inputs:
- Number
- User defined names for input signals
- Active signal level
:
:
:
4
yes
configurable via EM
- active ground
- active open.
MCN to FOX
Alarm interfaces
ABB
- Surge immunity
- Physical implementation
Alarm outputs:
- Number
- Type
:
:
page 43 of 68
2
solid state relays
double throw
overload protected
1KHW002006
- Use
- Physical implementation
alarm status of NE
- "Urgent Alarm
- "Non-urgent Alarm
COBU<X>
- Current admissible
- Resistance
- Open contact leakage current @ 75V
- Open contact max. voltage
- Immunity
- Surges
- Voltage (any alarm output lead to earth)
:
:
:
:
< 50 mA
< 50 Ohm
100 A
150 V
1 kV/50 Hz/60 s
:
:
active
not active
:
:
not active
not active
DC power interface
- Interface access
- Power converter units
:
:
FOX subrack *)
POSUM
POSUS
:
:
16 A
10 A
:
:
POSUA
POSUA
16 A
Power interfaces
1KHW002006
page 44 of 68
FOX515
FOX512
complementary specifications
below
ABB
:
:
:
EN 55022, class A
EN 55022, class B
EN 55022, class B
EN 55022, class B
IEC/EN 61000-4-3
IEC/EN 61000-4-6
Emission
Immunity
Electromagnetic field
80 MHz ... 2000 MHz, level 3, 10 V/m
Conducted common mode HF disturbance
150 kHz ... 80 MHz,
modulated 1 kHz 80% AM, 3 V
Fast transients/bursts
- on power supply IF (CDN)
- on traffic signal IFs (capacitive clamp)
Surge immunity
- Traffic and control IFs
:
:
:
IEC/EN 61000-4-4
1 kV
0.5 kV
:
:
- Differential mode
Electrostatic Discharge
- contact discharge
- air discharge
:
:
:
IEC/EN 61000-4-2
6 kV
8 kV
Safety according to
IEC/EN 60950-1
ESD
Safety
ABB
page 45 of 68
1KHW002006
Storage
All equipment (exclusive batteries) according to
Temperature range
Humidity
Biological and chemical active substances
Batteries (BATMO option)
:
:
:
:
Transport
Temperature ranges
- ambient air for unventilated enclosures
- ambient air for ventilated enclosures or outdoor
Humidity
Vibration random Acceleration Spectral Density
- ASD @ 10-200 Hz
- ASD @ 200-2000 Hz
Biological and chemical active substances
Batteries (BATMO option for FOX512)
:
:
:
-25C .. +70C
-25C .. +40C
according to class 2.2
:
:
:
:
1.0 m2s-3
0.3 m2s-3
Not specified
According to the specifications of the battery supplier
:
:
:
:
:
:
Not specified
Operation
1KHW002006
page 46 of 68
ABB
Dependability
Availability
Mean accumulated down time (MADT)
traffic between any two 2 Mbit/s ports of 2 NEs
:
:
:
> 20 years
refer to the unit descriptions.
MIL-HD BK-217F
MTTF
ABB
page 47 of 68
1KHW002006
1KHW002006
page 48 of 68
ABB
Powering
DC interface
Power supply interface according
Power consumption
- Maximum continuous current
- Maximum admissible power consumption
:
:
30 A
1200 Watt
Recommended fusing
:
:
1 interface
2 interfaces (DUPI4 option)
POSUM
POSUS
:
:
load sharing
5
:
:
n + 1 (n = 0 ... 4)
yes
Conversion
Protection
ABB
page 49 of 68
1KHW002006
Power dissipation
Maximum power dissipation
Maximum admissible power dissipation PD in
the FOX subrack (for ambient conditions)
- Natural air convection
(evenly distributed units in the subrack)
- Forced ventilation/air conditioning
- Range (with FANU5)
- Ventilation mandatory
:
:
PD 1200 W totally
PD > 150 W totally or
PD 11 W in any slot
provided that specified ambient conditions are fully met *)
FANU5
1KHW002006
page 50 of 68
ABB
Subracks
FOX515
Construction
Card cage for FOX units
Modularity
:
:
19-inch practice
subrack
cable tray
heat deflection shield
fan unit
:
:
direct
with adapters
Basic construction
- Sides and rear
- Top and bottom
- Front
:
:
:
:
metallic
sheet metal
perforated sheet metal
front cover
:
:
integrated connector(s)
single and dual power supply
supported
DUPI4 option
mechanically and electrically
integrated in the FOX515
subrack
:
:
Slots
- Number of slots
- Slot width
:
:
21
20.32 mm
4 TE
Segmentation of access
- ABUS
- PBUS
- SBUS
- UBUS
:
:
:
:
14 slots (2 sectors)
20 slots
14 slots (2 sectors)
21 slots
flexible
slot 11 dedicated
Unit construction
19-inch practice
1 HU (44.45 mm)
ABB
page 51 of 68
1KHW002006
:
:
direct
with adapters
front access
Number of fans
10
Operation
Temperature control of the fan speed
- minimum speed
- maximum speed
temperature controlled
:
:
20 C
35 C
Performance, average
- minimum speed (free blowing)
- air velocity
- transported air volume
- pressure drop
- noise
:
:
:
:
1 m/s
3
350 m /h
25 Pa
53 dBA @ 1 m
:
:
:
:
2 m/s
3
600 m /h
80 Pa
66 dBA @ 1 m
Types
- Optical indicators:
- Unit powered
- Partial unit failure
- Total unit failure
:
:
:
1 green LED
1 yellow LED
1 red LED
- Electrical contacts:
- Type
- Current
- Voltage drop @ 10 mA
- Open contact maximum voltage
:
:
:
:
:
solid state
10 mA
2V
-75 V
protected against reverse polarity
100 A
Connector
Voltage range
- nominal
- range
- switch on voltage (power up)
- switch off voltage (power down)
- resistance to reverse polarity
:
:
:
:
:
-48 VDC
-39.5 VDC -75 VDC
-35 VDC
-27 VDC
+75 VDC
:
:
0.6 A
1.2 A
Connector
Specification
Alarm interface
Power supply
1KHW002006
page 52 of 68
ABB
Ambient conditions
according to common features system specification, except
Operation
Temperature range
Minimum start up temperature
Humidity
:
:
:
Overall dimensions (W x H x D)
Construction
Weight FANU5 without packaging
Weight FANU5 power cable
Weight ETSI adapters 1 HU
:
:
:
:
:
:
:
> 5 years
> 1000 years
Power inputs
U1
U2
UTF
Alarm outputs
Supervision U1
Supervision U2
+75 VDC
30 A
10 W
Mechanical parameters
Reliability
MTTF @ 35C ambient temperature
Specifications
ABB
page 53 of 68
1KHW002006
Alarm interface
Alarm threshold voltage
-33 3 VDC
Electrical contacts:
- Type
- Current
- Voltage drop @ 10 mA
- Open contact maximum voltage
- Leakage current @ -75 V
:
:
:
:
:
solid state
10 mA
2V
-75 V
100 A
Connector
Installation
Mechanically integrated in
FOX515 subrack
Overall dimensions (W x H x D)
0.41 kg
MTTF @ 35C
1610 years
Mechanical parameters
Reliability
1KHW002006
page 54 of 68
ABB
:
:
:
:
Weight
ABB
6..81 kg
1.13 kg
Cable tray
Power cable with WAGO connector block
:
:
0.53 kg
0.08 kg
1.27 kg
:
:
:
:
:
0.09 kg
0.36 kg
0.41 kg
0.45 kg
0.49 kg
:
:
page 55 of 68
1KHW002006
Installation
Subrack, cable tray
Construction and installation
Height of subrack and cable tray
Installation into ETSI racks
Torques
- 19-inch / ETSI equipment and adapters M6 (4.8)
- DUPI4 unit
- Grounding/bonding terminal
- Unit front covers M2.5
:
:
:
19-inch practice
8 HU (= 355.6 mm)
with adapters
:
:
:
:
max. 4.7 Nm
max. 0.34 Nm
max. 2.0 Nm
max. 0.56 Nm
:
:
:
:
:
DIN 41 612
32 pins, rows a, c (b)
unit
proprietary
where applicable
yes
grounding bar, cable tray
Connection of signals
Male connector
Connector cover
Coding keys
Latching system
Strain relief
:
:
- Q1-interface
- Strain relief
SUBMINI D, 9 p./f.
10BASE-T (RJ-45)
half-duplex
DIN 41 612
8 pins, rows a, c
latching system
grounding bar, cable tray
- Alarm inputs/outputs
:
:
DIN 41 612
8 pins, rows a, c
DIN 41 612
8 pins, rows a, c
yes
grounding bar, cable tray
:
:
- Connector type
1 standard
2 with DUPI4 option
4 pin FAST-ON type connector
1KHW002006
page 56 of 68
ABB
- Connection
ABB
page 57 of 68
1KHW002006
1KHW002006
page 58 of 68
ABB
Powering
DC interface
Power supply interface according
Interface access
subrack
:
:
:
:
10.0 A
10 A slow blow
- Protected
1
on the cable tray
2
with DUPOS
Interface access
POSUA
:
:
:
:
Frequency
45 Hz 63 Hz
not possible
:
:
140 W
126 W
AC interface
ABB
page 59 of 68
1KHW002006
2.8 A
:
:
< 2.0 A
< 1.0 A
Interface access
POSUA
Charger interface
- nominal voltage @ 20C
- temperature compensation
:
:
-54.8 VDC
+110 mV/C
3A
:
:
:
:
:
3 m / 3 x 1.5 mm
:
:
320 W
180 W
POSUM
POSUS
POSUA
POSUA
:
:
:
1+1
yes
yes
:
:
no
no (only 1 unit)
protection of primary voltage
Power consumption
Protection
1KHW002006
page 60 of 68
ABB
- load sharing
- life insertion of converter units
:
:
:
:
with POSUM/POSUS
yes with POSUM/POSUS
:
:
yes
no
:
:
yes
not possible
PD 60 W totally and
PD < 11 W in any slot
Power dissipation
Vertical installation
Horizontal installation
Maximum admissible power dissipation
- Natural air convection (for specified ambient)
- Forced ventilation with FANU2 (R2) fan unit
:
:
not admitted
PD 320 W
ABB
page 61 of 68
1KHW002006
Subracks
FOX512
Construction
Card cage for FOX units
Modularity
:
:
proprietary subrack
versatile subrack with
- 19-inch adapter
- ETSI adapters
- wall-mounting adapter
:
:
with adapter
19-inch with adapters
with adapter
Basic construction
- Sides and rear
- Top and bottom
- Front
Connection of signal and power cables
- Power supply (DC)
- Shields of signal cables
- Cable installation and strain relief
:
:
:
:
metallic
sheet metal
perforated sheet metal
front cover
:
:
:
integrated connector
grounding bars in front
installation adapters with
cable tray
Slots
- Number of slots
8 standard
1 special for fan unit
20.32 mm
4 TE
Segmentation of access
- ABUS
- PBUS
- SBUS
- UBUS
:
:
:
:
5 slots
7 slots (incl. slot 11)
5 slots
8 slots (incl. slot 11)
flexible
slot 11 dedicated
Unit construction
Installation
Specification
1KHW002006
page 62 of 68
ABB
Number of fans
Operation
temperature controlled
- low speed
- high speed
:
:
< 27 C
> 45 C
Performance (average)
- low speed (free blowing)
- air velocity
- transported air volume
- noise
:
:
:
1 m/s
3
70 m /s
46 dBA @ 1 m
:
:
:
2 m/s
3
120 m /s
56 dBA @ 1 m
Types
- Optical indicator
- Local failure indicator
- Failure and alarm indication
:
:
1 red LED
integrated with the FOX
alarm system
- Electrical contacts
- Local contacts
- Failure and alarm indication
:
:
none
integrated with the FOX
alarm system
Supply circuit
-48 VDC
(internal power rail)
:
:
< 120 mA
< 250 mA
Alarm interface
Power supply
ABB
page 63 of 68
1KHW002006
Reliability
MTTF @ 35 C ambient temperature
- MTTF for partial failure
- MTTF for total unit failure
:
:
> 50 years
> 1000 years
Basic construction
- Sides
- Rear
- Top and bottom
- Front
Battery power cable
:
:
:
:
:
:
4 (48 VDC)
Battery type
- Nominal voltage
- Nominal capacity
Mechanical parameters:
- Dimensions max. (W x H x D)
- Weight
- Cable terminals
Recommended commercial grade batteries
:
:
maintenance-free
lead batteries
12 VDC
17 Ah
Batteries
:
:
:
:
77 x 168 x 183 mm
ca. 6.5 kg
bolts and nuts M5
YUASA NP17-12I
Panasonic LC-RD1217P
or equivalent products
up to 4 years
:
:
-10 C + 55 C
-10 C + 40 C
:
:
0 C
-20 C
1KHW002006
page 64 of 68
ABB
:
:
:
:
:
:
:
:
:
:
4.71 kg
4.07 kg
:
:
:
4.89 kg
5.06 kg
5.67 kg
:
:
:
0.64 kg
0.07 kg
0.11 kg
Weight of units
BATMO battery package
- case without batteries
- case with batteries
:
:
4.2 kg
ca. 32 kg
Weight
ABB
page 65 of 68
1KHW002006
Installation
Subrack, cable tray
Construction and installation
4 HU (= 177 mm)
Installation
- in 19-inch racks (horizontal, vertical)
- in ETSI racks (horizontal, vertical)
- on walls or in cabinets (vertical)
:
:
:
with adapter
with adapters
with adapter
Cable tray
19-inch adapter
wall-mounting adapter
Torques
- 19-inch / ETSI equipment and adapters M6 (4.8) :
- Angle bracket M4 (4.8)
:
- Unit front covers M2.5
:
max. 4.7 Nm
max. 1.3 Nm
max. 0.56 Nm
Installation
- wall- and cabinet-mounting
- ground installation
:
:
:
:
:
:
:
DIN 41 612
32 pins, rows a, c (b)
unit
proprietary
where applicable
yes
grounding bar, cable tray
:
:
- Q1-interface
- Strain relief
Auxiliary signals (control unit)
- Synchronisation inputs/outputs
SUBMINI D, 9 p./f.
10BASE-T (RJ-45)
half-duplex
DIN 41 612
8 pins, rows a, c
latching system
grounding bar, cable tray
- Alarm inputs/outputs
Connection of signals
1KHW002006
Male connector
Connector cover
Coding keys
Latching system
Strain relief
page 66 of 68
DIN 41 612
8 pins, rows a, c
DIN 41 612
ABB
:
:
8 pins, rows a, c
yes
grounding bar, cable tray
:
:
:
:
ABB
page 67 of 68
POSUA front
3-pin WAGO plug
1KHW002006