Side Channel Blower: G-2RB 2RB 810
Side Channel Blower: G-2RB 2RB 810
Side Channel Blower: G-2RB 2RB 810
G-2RB
2RB 810
Performance curve for Compressor
mbar
mbar
power requirement P
on the pump shaft (kW)
power requirement P
on the pump shaft (kW)
mbar
mbar
mbar
mbar
Each G-2RB type can be applied both as vacuum pump and compressor in
continuous operation over the total stated performance curve range. The
motors are available as standard for the input voltage range of 50 and 60 Hz
and for protection category IP 55 as well as approbated for UL and CSA.
Order No.
FreRated
quency power
Hz
kW
Input voltage
Input
current
Permissible total
differential pressure )
Sound
pressure
level )
Weight
ca.
Vacuum
mbar
Compressor
mbar
dB(A)
kg
2RB810-7AH07
2RB810-7AH07
50
60
4.0
4.6
600Y...720Y
660Y...720Y
9.5D
9.5D
5.5Y
5.5Y
-200
-160
200
160
70
74
54
54
A 342
A 343
A 344
A 345
2RB810-7AH17
2RB810-7AH17
2RB810-7AH27
2RB810-7AH27
50
60
50
60
5.5
6.3
7.5
8.6
600Y...720Y
660Y...720Y
600Y...720Y
660Y...720Y
12.9D
12.9D
16.7D
17.3D
7.4Y
7.45Y
9.6Y
10.0Y
-300
-300
-320
-350
300
280
430
400
70
74
70
74
63
63
66
66
Dimensions: (inches)
17.62
20.05
9.46
4.87
6.69
2.57
2 1/2"
NPT (2)
0.59 (4)
5.98
14.02
17.05
Specifications subject to change without notice. Please contact factory for specification updates.
185...225 V D/320...390 V Y
200...240 V D/345...415 V Y
345...415 V D
60Hz
200...240 V D/345...415 V Y
200...275 V D/380...480 V Y
380...480 V D
500 V D
575 V D
Machines according to the ATEX norm 94/4 EG are available
for the whole performance range.
Following types available: Category 3 G, 3/2 G, 3 D and 3/2 D.
H 1
H 6
H 7
C 5
All G-2RB achieve the standards and norms of the low voltage directive
(LVD)2006/95/EC, rotating electrotechnical motor EN 60034-1-2004,
electromagnetic compatibility(EMC)EN55014-1/2,EN61000-2/-3/-4/-6.
1) For standard UL for ELECTRIC MOTOR UL 1004-1.
2) Relief-valve are available for limiting differential pressure.
3) Measuring-surface sound-pressure level acc. to DIN EN 21680, measured
at a distance of 1 m. The pump is throttled to an average suction pressure,
a hose is connected to the discharge side (compressor) / suction side
(vacuum pump), but is not fitted with relief valves.
The motors are designed according to the DIN EN 60 034 / DIN IEC 34-1 and
temperature class F.
For the three phase machines the tolerances are +/- 10 % for fixed voltage and
+/- 5 % for voltage range.
The single phase machines are designed with a +/- 5 % tolerances. If only 90 %
of the maxium allowed pressure will be used for the continuousoperating then
the allowed voltage range add to +/- 10 %.
For all single and three phase machines which designed according to the UL and
CSA norm (UL 1004-1) the maximum allowed voltage tolerances are - 10 % resp.
+ 6 %.
The frequency tolerance is maximum +/- 2 %.
Changes in particular the quoted performance curve, datas and weights without prior notice. The figures are without obligations.