Brushless Vexta Motor AXH
Brushless Vexta Motor AXH
Brushless Vexta Motor AXH
AXH Series
More compact, Higher power.
DC power supply drive type package with brushless
DC motor and compact board-level driver.
The AXH series is optimal for incorporation as a set
in equipment where space-saving is required.
The AXH series comes with the motor and its
dedicated gearhead already assembled
(Combination Type).
AXH
AC Speed
Control Motor
Serie
71m
ie
100
m
53mm
26mm
m
42mm
H
Driver volume reduced
by approximately 60%
95mm
80mm
70
m
54 m
m
m
The total length of the motor section for the AXH series
has been designed to a thin 42mm.
High power output (50W) with the frame size of 80mm has
been realized.
80mm
Features
36mm
Torque
1000
2000
Speed [r/min]
3000
A-120
Features A-120
Specifications A-122
Safety Standards
Standards
UL1950
CSA C22.2 No.950
UL1950
CSA C22.2 No.950
Motor
Driver
Certification Body
UL
E208200
UL
E208200
Installation Conditions
The product is to be used as component within other equipment.
Overvoltage category
Pollution degree 2
Class equipment
Introduction
System Configuration
Driver
DC 24V
Power Supply
AXH
AXH Series
Example of System Configuration
(Body)
Motor Mounting
Bracket
SOL4M6
Flexible
Coupling
MCL401515
External Speed
Potentiometer
PAVR-20KZ
Motor Speed
Indicator
SDM496
US
Extension Cables
(1.5m)
FC02HBL
SC
Electromagnetic
Brake Motors
The system configuration shown above is an example. Other combinations are available.
Torque
Motors
Splash
Proof
Motors
AXH 4 50 K Series
AXHAXH Series
MSSW
Combination Type
AXH450K-30
(Sold separately)
AXU
Programmable
Controller
FBL
Combination Type
(Motor/Gearheads)
Reversible
Motors
Induction
Motors
Flexible Couplings
(Sold separately)
(Page A-301)
Gearheads
Product Lines
Combination Type
Model
AXH230K-
AXH450K-
Linear
Heads
Output Power
30W
50W
Gear Ratio
5, 10, 15, 20, 30, 50, 100, 200
5, 10, 15, 20, 30, 50, 100, 200
Accessories
Enter the gear ratio in the box () within the model number.
Before Using
a Standard
AC Motor
Output Power
30W
50W
Model
AXH230K-A
AXH450K-A
A-121
Standard AC Motors
Specifications
Rated
Output Power
Model
Combination Type
AXH230K-
AXH230K-A
W
30
Rated Torque
Starting Torque
Nm
kgfcm
0.12
1.2
0.20
2.0
Nm
kgfcm
0.15
1.5
0.24
2.4
3.5
DC24V 10
AXH450K-
AXH450K-A
50
Common Specifications
Item
Speed Control Method
Input Signals
Output Signals
Protection Functions 1
Specifications
Any one of the following methods.
1. By built-in potentiometer
2. By external potentiometer
3. By DC voltage (DC05V)
C-MOS negative logic
L : (ON) : 00.5V
H : (OFF) : 45V
START/STOP input
L : START
H : STOP
Brake input
L : RUN
H : Instantaneous stop
Direction of Rotation input
L : CW
H : CCW
L : Internal
Speed setting method
H : External
Alarm reset
L : Reset
H : Normal
Open collector output External use conditions DC 26.4V, 10mA max.
Common to SPEED (30P/R), Alarm
When the following are activated, the alarm signal will be output and the motor will come to a natural stop.
Overload Protection: This will be activated when a load exceeding the rated torque is applied to the motor for approximately 5 seconds or more.
Out-of-Phase Protection: This will be activated when the sensor wire inside the motor cable is disconnected.
Overvoltage Protection: This will be activated when the voltage applied to the driver exceeds DC24V by approximately 15% or more.
Under Voltage Protection: This will be activated when the voltage applied to the driver goes under DC24V by approximately 25% or more.
Over Speed Protection: This will be activated when the motor rotates at an abnormal speed far beyond 3500r/min.
Class E (120C)
Continuous
1 With the AXH series, the motor speed can not be controlled in applications where the motor shaft is turned by the load, as in lowering operations.
Also, if the load driven exceeds the permissible load inertia and during load lowering operation, the overvoltage protection function is activated and the
motor stops naturally.
2 Motor insulation is recognized as class A (105C) by UL standard.
General Specifications
Insulation Resistance
Item
Motor
100M or more when DC500V megger is applied between the windings
and the frame after continuous operation under normal ambient
temperature and humidity.
Driver
100M or more when DC500V megger is applied between the power supply input
and the frame after continuous operation under normal ambient temperature and
humidity.
Dielectric Strength
Sufficient to withstand AC0.5kV at 50Hz applied between the windings and the
frame for 1 minute after continuous operation under normal ambient temperature
and humidity.
Temperature Rise
Ambient Temperature
Ambient Humidity
Atmosphere
0C50C (nonfreezing)
85% maximum (noncondensing)
No corrosive gases or dust
AXH230K-
AXH450K-
20 500
5
0.54
5.4
10 250
10
1.1
11
6.7 167
15
1.6
16
5 125
20
2.2
22
3.3 83
30
3.1
31
2 50
50
5.2
52
1 25
100
6
60
0.5 12.5
200
6
60
0.9
9
1.8
18
2.7
27
3.6
36
5.2
52
8.6
86
16
160
16
160
Enter the gear ratio in the box () within the model number.
A colored background indicates gear shaft rotation in the same direction as the motor shaft; a white background indicates rotation in the opposite
direction.
A-122
Features A-120
Specifications A-122
Rated
Speed
Speed
Control Range
r/min
r/min
r/min
3000
2500
Speed Regulation
For Load
1003000
Speed ratio of
130
Maximum
Speed
For Voltage
For Temperature
1 Max.
Power supply voltage10%
at rated speed with no load
1 Max.
0rated torque,
at rated speed
1 Max.
0C50C,
at rated speed with no load
Introduction
Induction
Motors
AXH230K-
kgf
40
100
10
Enter the gear ratio in the box () within the model number.
AXU
AXH230K-A
AXH450K-A
AXH
Model
US
Gear Ratio
AXH230K-
10
6.2
25
15
14.0
56.3
20
24.8
100
30
55.8
225
50
155
625
100
155
625
200
155
625
5.5
22.5
22
90
49.5
203
88
360
198
810
550
2250
550
2250
550
2250
Electromagnetic
Brake Motors
AXH450K-
5
1.55
6.25
SC
Model
Enter the gear ratio in the box () within the model number.
Splash
Proof
Motors
Speed-Torque Characteristics
Torque
Motors
For the combination type, the values are for the motor alone.
Enter the gear ratio in the box () within the model number.
Values for DC24V with no extension cable
AXH450K-/AXH450K-A
[kgfcm] [Nm]
3
0.3
Starting Torque
of
Rated Torque
of
Rated Torque
0
1000
2000
Speed [r /min]
3000
Rated Torque
0.1
0
1000
2000
Speed [r /min]
3000
Before Using
a Standard
AC Motor
Torque
1.2 0.12
1 0.1
0.24
0.2
Accessories
Torque
1.5 0.15
2.4
2
Starting Torque
Linear
Heads
Rated Torque
Gearheads
AXH230K-/AXH230K-A
[kgfcm] [Nm]
2 0.2
MSSW
AXH450K-
FBL
5
10,15,20
30,50,100,200
5
10,15,20
30,50,100,200
Reversible
Motors
Model
A-123
Standard AC Motors
Unit = mm)
Mounting screws are included with the combination type. Dimensions for screw included Page A-321
Enter the gear ratio in the box () within the model number.
Motor/Gearhead
60
4-4.5
42
0
24
8 2
0.5
0.5
70
500
500
60
16
60
4-4.5
0
540.030
(h7)
0
100.015
(h7)
10
24
34(38) 32
8 43 4
25
60
42
7.5
0
80.015
(h7)
for GFH2G520
( ) for GFH2G30100
for GFH2G200
0.1
0
0.040
0
40.03
2.5
250.2
40.03
Motor/Gearhead
42
32
8 2
.5
0
94
.5
0
94
500
500
9.5
80
25
80
4-6.5
0
730.030
h7
80
4-6.5
13
34
41(46) 351
51 7 25
80
0
150.018
(h7)
42
0
100.015
h7
Housing:171822-8 (AMP)
Housing: 171822-8AMP
for GFH4G520
( ) for GFH4G30100
for GFH4G200
A-124
0.040
0
0.1
0
50.03
250.2
50.03
Features A-120
Specifications A-122
Driver
711
630.2
541
34.50.2
Induction
Motors
Introduction
AXHD30K
AXHD50K
Mass: 0.1kg
2-3.5
Reversible
Motors
3.5
AXU
300
US
SC
MSSW
261
220.2
640.2
FBL
3.5
Electromagnetic
Brake Motors
Splash
Proof
Motors
Torque
Motors
Gearheads
Linear
Heads
Accessories
Before Using
a Standard
AC Motor
A-125
Standard AC Motors
Brown
Alarm Output
Red
Speed Output
Orange
GND
Yellow
DC 05V _
1mA
Minimum +
External DC Power Supply
Green
24V
GND
1
2
ALARM Output
SPEED Output
GND
4
5
VRL
CN1
VRM
VRH
CN2
7 ALARM-RESET Input (I/O)
Brown
8 INT.VR./EXT. Input
Purple
Reset
Alarm Reset Input L(ON):
H(OFF): Normal
Speed Potentiometer L(ON): Internal
Selection Input
H(OFF): External
Rotation Direction L(ON) : CW
H(OFF): CCW
Switching Input
Run
Brake Input L(ON):
H(OFF): Brake
Start/Stop Input
1
2
Gray
White
Black
L(ON) :Start
H(OFF): Stop
10
CW/CCW
RUN/BRAKE
11
START/STOP
12
N.C.
CN3
INT.VR.
Motor
Motor
When the motor cable is extended, use an optional extension cable (sold separately, 1.5m).
Extension Cable Page A-309
2-Speed Switching/Stop
2500r/min
1000r/min
CWClockwise
Motor Operation Pattern
CCW (Counterclockwise)
START/STOP Input
"H"(OFF)
"L" (ON)
CW/CCW Input
"H"(OFF)
"L" (ON)
CW
RUN/BRAKE Input
"H"(OFF)
"L" (ON)
RUN
INT.VR./EXT.Input
"H"(OFF)
"L" (ON)
SPEED Output
"H"(OFF)
"L" (ON)
START
EXT.
START
INT.VR.
CCW
EXT.
CW
RUN
RUN
INT.VR.
EXT.
Run/stop, instantaneous stopping and rotation direction switching operations can all be controlled with the START/STOP,
RUN/BRAKE and CW/CCW signals.
If both the START/STOP signal and the RUN/BRAKE signal are set to L level (ON), the motor rotates. At this time, if the
CW/CCW signal is set to L level (ON), then the motor rotates clockwise as seen from the motor shaft side; if the CW/CCW
signal is set to H level (OFF), the motor rotates in the counterclockwise direction.
If the RUN/BRAKE signal is set to H level (OFF) while the START/STOP signal is L level (ON), the motor stops
instantaneously. If the START/STOP signal is set to H level (OFF) while the RUN/BRAKE signal is set to L level (ON), the
motor stops naturally.
The duration of each input signal must be 10msec or longer.
Do not operate (turn ON/OFF) two or more input signals simultaneously. There must be a minimum interval of 10msec
after an input signal is operated before another input signal can be operated.
A-126
Features A-120
Specifications A-122
Introduction
C-MOS
Input
0.1F
GND
Induction
Motors
Reversible
Motors
Run
Brake
Start
Stop
GND
VRL
VRM
VRH
ALARM-RESET Input
INT.VR./EXT. Input
CW/CCW
10
RUN/BRAKE
11
START/STOP
12
N.C.
US
CN2
I/O
SC
Control by Controller
Controller
Transistor
C-MOS type
Input
START/STOP
RUN/BRAKE
CW/CCW
INT.VR./EXT.
ALARM-RESET
Input
C-MOS
GND
GND
Driver
5V
START/STOP
RUN/BRAKE
CW/CCW
INT.VR./EXT.
ALARM-RESET
GND
Splash
Proof
Motors
GND
Controller
Driver
Electromagnetic
Brake Motors
CCW
SPEED Output
CW
MSSW
External
ALARM Output
AXH
ON
Internal
AXU
OFF
FBL
Torque
Motors
Gearheads
Linear
Heads
Accessories
Before Using
a Standard
AC Motor
A-127
Standard AC Motors
Output
External Use
Condition
DC26.4V Max.
10mA Max.
GND
Driver
Vcc
SPEED
ALARM
R
2SC2458
equivalent
GND
SPEED Output
The system outputs pulse signals (with a width of 0.3ms) at a rate
of 30 pulses per rotation of the motor output shaft synchronized
with the motor drive.
You can measure the SPEED output frequency and calculate the
motor speed.
0.3 ms
T
ALARM Output
The ALARM output is normally L level (ON) and goes H level (OFF) when there is an alarm.
ALARM-RESET
When the motor is stopped, setting this signal L level (ON), then returning it to H level (OFF) resets the alarm.
Please return either the START/STOP input or the RUN/BRAKE input to H level (OFF) before inputting the ALARM-RESET.
The ALARM-RESET is not accepted if both these signals are L level (ON).
Note:
Output signal is open collector output, so an external power supply (Vcc) is required.
Use a power supply of no more than DC26.4V and connect a limit resistance (R) such that the output current does not
exceed 10mA.
When using neither the speed output function nor the alarm output function, this connection is not required.
A-128
Features A-120
Specifications A-122
ON
OFF
8
Induction
Motors
High
Speed
External Potentiometer
3500
High Speed
3000
1 2 3
2500
2000
1500
AXU
1000
500
20
100
When setting the motor speed with an external DC voltage, do so in the following manner.
3500
US
3000
DC 05V
1mA Min.
4
5
2500
2000
SC
Speedr/min
Driver
1500
1000
DC voltageVDC
Torque
Motors
Driver Model
AXHD30K
AXHD50K
Gearheads
Motor Model
AXHM230K-GFH
AXHM450K-GFH
Enter the gear ratio in the box () within the model number.
Linear
Heads
Driver Model
AXHD30K
AXHD50K
Accessories
Output Power
Model
30W
AXH230K-A
50W
AXH450K-A
Splash
Proof
Motors
Electromagnetic
Brake Motors
500
Output Power
Model
30W
AXH230K-
50W
AXH450K-
MSSW
External DC Voltage
AXH
40
60
80
Scale plate value
Driver
FBL
Speedr/min
Reversible
Motors
When separating the motor speed setting from the driver, connect the optional external potentiometer as follows.
Before Using
a Standard
AC Motor
A-129