Process Control Presys
Process Control Presys
Process Control Presys
Instrumentos e Sistemas
EMENT SYS
AG
Calibrao
NBR ISO/IEC
17025
QUA ITY
L
CAL 0193
M
TE
PRESYS
MA
N
Instrumentation and
Process Control
OCP 0004
EF-0241-01
presys
TABLE OF CONTENTS
page
INDICATORS
Digital Multi-point Indicator - DMY-2015 / DMY-2015-PB (Profibus)
02
04
06
08
10
11
12
14
15
16
18
CONTROLLERS
Universal Process Controllers - Single Loop - DCY-2050-Light / DCY-2050-F-Light / DCY-2051-Light /
DCY-2051-F-Light / DCY-2060-Light / DCY-2060-F-Light
20
22
24
25
26
TRANSMITTERS / CONVERTERS
Universal Smart Transmitter - TY-2090 / TY-2090-F
28
30
31
32
34
Data Acquisition
Data Acquisition Module - TY-2095 / TY-2095-PB (Profibus)
36
ACCESSORIES / DIMENSIONALS
Internal Optional Modules / Configurators
38
Explosion-proof Panel
40
Dimensional Drawings
42
HART CONFIGURATOR
HART Field Communicator - FCY-15
46
presys
Digital Multi-point
Indicator
DMY-2015 and
DMY-2015-PB
Totalization function.
Many optional Modules are available:
- Up to 2 SPDT relays alarm modules.
- One retransmitter output 1-5 Vdc, 4-20 mA
or 0-10 Vdc, which can retransmit any input signal or the
mean of selected channels configuration. (item upon request).
- Galvanic isolation between inputs, outputs and power supply.
- Isolation between inputs is also available upon request.
- RS-232, RS-422/485 Communication (MODBUS RTU Protocol) or PROFIBUS (DP-V0)*.
- Aspersion-proof front-panel.
Configurable display for up to 4-digit of high visibility for the process variable indication. Another
display shows which channel is being displayed. Still has twelve LEDs that may indicate alarm
states for each channel.
presys
Order Code
Model
DMY-2015
DMY-2015-PB
Inputs
0 - 12 TC inputs
1 - 8 RTD inputs
2 - 6 TC and 4 RTD inputs
3 - 12 current inputs
4 - 12 voltage inputs
5 - 6 TC and 6 current inputs
6 - 6 TC and 6 voltage inputs
7 - 6 current and 6 voltage inputs
8 - 6 current and 4 RTD inputs
9 - 6 voltage and 4 RTD inputs
Output 1
0 - None
1 - SPDT Relay
2 - Open Collector Voltage
3 - Solid State Relay
Output 2
Same code as output 1
Power Supply
1 - 75 to 264 Vac 50/60 Hz or 100 to 360 Vdc (any polarity)
2 - 24 Vac or 24 Vdc (10 %)
3 - 12 Vdc (10 %)
4 - Others, upon request
Communication
0 - None
1 - MODBUS (RS-232)*
2 - MODBUS (RS-485)*
3 - MODBUS (RS-422)*
4 - PROFIBUS DP-V0 (RS-485)**
Specifications
Inputs
Thermocouple (J, K, T, E, R, S under ITS-90).
RTD Pt-100 under DIN 43760.
4-20 mA with input impedance of 250 .
1 to 5 Vdc with input impedance >10 M.
Outputs
Up to 2 SPDT relays rated for 3A/220 Vac.
Logic signal, open collector transistor, 24 Vdc/40 mA
maximum with isolation. Solid state relay,
2A/250 Vac with isolation.
Serial Communication
DMY-2015: RS-232 or RS-422/485 with 50 Vdc isolation.
MODBUS-RTU Communication Protocol.
DMY-2015-PB: PROFIBUS DP-V0: RS-485 Communication.
Indication
4-digit red leds display (14 mm) for process variable indication.
2-digit display for channel indication. 12 red leds for alarm
indication.
Totalization
Totalization of eight voltage or current inputs ranging from
0 to 9999, configured with the decimal point.
Configuration
By front-panel push-buttons
Sampling Rate
480 ms standard, for all inputs. One second display update rate.
Accuracy
0.1 % of full scale for TC, RTD, mA, Vdc.
Linearization
0.1 C for RTD and 0.2 C for TC.
Square Root Extraction
0.5 % of reading, for input above 10 % of span.
Programmable Cut-off from 0 to 5 %.
Cold Junction Compensation
2.0 C in ambient temperature range from 0 to 60 C.
Span Temperature Coefficient
0.005 % of span / C using 25 C as the reference temperature.
Power Supply
75 to 264 Vac 50/60 Hz or 100 to 360 Vdc
(10 W nominal); 24 Vac/dc (10 %); 12 Vdc (10 %).
Operating Range
0 to 60 C temperature and 90 % maximum relative humidity.
Dimensions
1/4 DIN (96 x 96 x 187 mm) HxWxD, (92 x 92 mm) HxW panel
cutout.
Weight
0.7 kg nominal.
Warranty
One year.
presys
Universal Digital
Indicator Single
DMY-2030-Light
DMY-2030-Light: Universal input for RTD, thermocouples, 0-55 mV, 4-20 mA,
1-5 Vdc and 0-10 Vdc.
4 digit display of high visibility.
Linearization for RTD and TC, square root extraction function.
Power supply of 75-264 Vac, 50/60 Hz or 100 to 360 Vdc; 24 Vac/dc and 12 Vdc,
as ordered.
Fully configurable by front-panel push-buttons. Configuration stored in non-volatile memory.
Many optional modules are available:
- Analog output modules of 4-20 mA, 1-5 Vdc and 0-10 Vdc.
- Up to 2 SPDT relay alarm modules.
- Aspersion-proof front-panel.
- Communication RS-232 or RS-422/485 with computer.
High accuracy.
presys
Order Code
DMY
Model
2030-Light
Output 1
0
1
2
3
None
4-20 mA
1-5 Vdc
0-10 Vdc
Output 2
0
1
2
3
None
SPDT Relay
Open Collector Voltage
Solid State Relay
Output 3
Same code as Output 2
Power Supply
1 - 75 to 264 Vac 50/60 Hz or 100 to 360 Vdc (any
polarity)
2 - 24 Vac or 24 Vdc (10 %)
3 - 12 Vdc (10 %)
4 - Others, upon request
Communication
0
1
2
3
None
RS-232
RS-485
RS-422
Specifications
Inputs
Configurable for TC (J, K, T, E, R, S under ITS-90), 0-55 mV,
RTD under DIN 43760, 4-20 mA, 1-5 Vdc and 0-10 Vdc.
Input impedance of 250 for mA, >10 M up to 5 Vdc and
2 M above 5 Vdc.
Outputs
4-20 mA (750 maximum load), 1-5 Vdc or 0-10 Vdc analog
retransmitter. Galvanically isolated module to 300 Vac from power
supply and inputs. Up to 2 SPDT relay modules, rated for 3A/220 Vac.
Logic signal, open collector transistor, 24 Vdc/40 mA maximum with
isolation. Solid state relay, 2A/250 Vac with isolation.
Serial Communication
RS-232 or RS-422/485 with 50 Vdc isolation. MODBUS-RTU
Communication Protocol.
Indication
4 digit red leds display (14 mm).
Configuration
By front-panel push-buttons and internal jumpers.
Sampling Rate
64 ms standard.
Accuracy
0.1 % of full scale for TC, RTD, mA, mV and Vdc inputs.
0.5 % of full scale for analog retransmitter output.
Linearization
0.1 C for RTD and 0.2 C for TC.
Square Root Extration
0.5 % of reading, for inputs above 10 % of span.
Programmable cut-off from 0 to 5 %.
Cold Junction Compensation
2.0 C in ambient temperature range from 0 to 60 C.
2-Wire Transmitter Power Supply
24 Vdc/50 mA maximum, isolated from output, with short-circuit
protection.
Span Temperature Coefficient
0.005 % of span / C using 25 C as the reference temperature
Power supply
75 to 264 Vac 50/60 Hz or 100 to 360 Vdc
(10 W nominal); 24 Vac/dc (10 %); 12 Vdc (10 %).
Operating Ambient
0 to 60 C temperature and 90 % maximum relative humidity.
Dimensions
1/8 DIN (48 x 96 x 187 mm) HxWxD, (45 x 92 mm) HxW
panel cutout.
Weight
0.5 kg nominal.
Warranty
One year.
presys
Frequency
Digital Indicator
Single
DMY-2030-F-Light
presys
Order Code
DMY
Model
2030-F-Light: Frequency
Input.
Output 1
0
1
2
3
4
5
6
None
4-20 mA
1-5 Vdc
0-10 Vdc
SPST Relay
Open Collector Voltage
Solid State Relay
Output 2
0
1
2
3
None
SPST Relay
Open Collector Voltage
Solid State Relay
Output 3
0
1
2
3
None
SPDT Relay
Open Collector Voltage
Solid State Relay
Output 4
Same code as Output 3
Power Supply
1 - 75 to 264 Vac 50/60 Hz or 100 to 360 Vdc (any
polarity)
2 - 24 Vac or 24 Vdc (10 %)
3 - 12 Vdc (10 %)
4 - Others, upon request
Communication
0
1
2
3
None
RS-232
RS-485
RS-422
Specifications
Input
One frequency input to connect signals in the wave shapes sine,
square, triangle, pulse with amplitude between 300 mVpp and
30 Vpp and dry contact input. 70 Vdc maximum voltage.
Input impedance greater than 60 k
(sine wave, 1 kHz).
Outputs
4-20 mA (750 maximum load), 1-5 Vdc or 0-10 Vdc analog
retransmitter. Galvanically isolated module to 300 Vac from power
supply and inputs. Up to 2 SPDT + 2 SPST relay modules, rated
for 3A/220 Vac. Logic signal, open collector transistor, 24 Vdc/40 mA
maximum with isolation. Solid state relay, 2A/250 Vac with isolation.
Serial Communication
RS-232 or RS-422/485 with 50 Vdc isolation.
MODBUS-RTU Communication Protocol.
Indication
4 digit red leds display (14 mm).
Configuration
By front-panel push-buttons and internal jumpers
Sampling Rate
71 ms standard.
Half second display update rate.
Accuracy
1 Display resolution for input.
0.5 % of full scale for analog retransmitter output.
Power Supply for frequency sensors
24 Vdc / 50 mA maximum, isolated from output with
short-circuit protection.
Power Supply
75 to 264 Vac 50/60 Hz or 100 to 360 Vdc
(10 W nominal); 24 Vac/dc (10 %); 12 Vdc (10 %).
Operating Range
0 to 60 C temperature and 90 % maximum relative
humidity.
Dimensions
1/8 DIN (48 x 96 x 187 mm) HxWxD, (45 x 92 mm)
HxW panel cutout.
Weight
0.5 kg nominal.
Warranty
One year.
presys
Universal
Process
Indicator
Dual
DMY-2030 / DMY-2030-F
DMY-2035 /
DMY-2035-F
DMY-2011 /
DMY-2011-F
DMY-2036 / DMY-2036-F
presys
Order Code
DMY
Model
Output 1
0
1
2
3
4
5
6
None
4-20 mA
1-5 Vdc
0-10 Vdc
SPST Relay
Open Collector Voltage
Solid State Relay
Output 2
Output 3
0
1
2
3
None
SPDT Relay
Open Collector Voltage
Solid State Relay
Output 4
Power Supply
Communication
0
1
2
3
None
RS-232
RS-485
RS-422
* Explosion-proof box:
Dimensions
Weight
11 kg approx.
Specifications
Inputs
DMY-2030/2011/2035/2036: Two configurable inputs for
thermocouple (J, K, T, E, R, S under ITS-90), 0-55 mV,
RTD Pt-100 under DIN 43760, 4-20 mA,1-5 Vdc and
0-10 Vdc. 4-20 mA with input impedance of 250 .
>10 M up to 5 Vdc and 2 M above 5 Vdc.
DMY-2030-F/2011-F/2035-F/2036-F: Two frequency inputs
for signals up to 30 kHz, from 300 mVpp to 30 Vpp.
Outputs
4-20 mA (750 maximum load), 1-5 Vdc or 0-10 Vdc
analog retransmitter. Up to 2 galvanically isolated modules
to 300 Vac from power supply and inputs. Up to 2 SPDT
relay modules and up to 2 SPST relay modules, rated for
3A/220 Vac. Logic signal, open collector transistor,
24 Vdc/40 mA maximum with isolation. Solid state relay,
2A/250 Vac with isolation.
Note: In the case of using an analog output, one can use
three alarm modules, or when using two analog outputs,
one can use up to two alarm modules.
Serial Communication
RS-232 or RS-422/485 with 50 Vdc isolation.
MODBUS-RTU Communication Protocol.
Indication
DMY-2030/2030-F: 4 digit red leds display (14 mm).
DMY-2011/2011-F: 2 x 4-digit red leds display (14 mm).
DMY-2035/2035-F: 2 x 4-digit red leds display (9 mm).
DMY-2036/2036-F: 2 x 4-digit red leds display (14 mm and
9 mm). Can be configured together with the decimal point.
Configuration
By front-panel push-buttons and internal jumpers
Sampling Rate
120 ms standard. One second display update rate.
Accuracy
0.1 % of full scale for TC, RTD, mA, mV and Vdc.
0.5 % of full scale for analog retransmitter output.
1 Display resolution for frequency input.
Linearization
0.1 C for RTD and 0.2 C for TC.
Square Root Extraction
0.5 % of reading, for input above 10 % of span.
Programmable Cut-off from 0 to 5 %.
Cold Junction Compensation
2.0 C in ambient temperature range from 0 to 60 C.
2-wire Transmitter Power Supply
24 Vdc/50 mA maximum, isolated from output with
short circuit protection.
Span Temperature Coefficient
0.005 % of span / C using 25 C as the reference
temperature.
Power Supply
75 to 264 Vac 50/60 Hz or 100 to 360 Vdc
(10 W nominal); 24 Vac/dc (10 %); 12 Vdc (10 %).
Operating Range
0 to 60 C temperature and 90 % maximum relative
humidity.
Dimensions
DMY-2030/2030-F:1/8 DIN (48 x 96 x 187 mm) HxWxD,
(45 x 92 mm) HxW panel cutout .
DMY-2011/2011-F:1/4 DIN (96 x 96 x 187 mm) HxWxD,
(92 x 92 mm) HxW panel cutout .
DMY-2035/2035-F: 1/8 DIN (96 x 48 x 187 mm) HxWxD,
(92 x 45 mm) HxW panel cutout .
DMY-2036/2036-F: 1/8 DIN (48 x 96 x 187 mm) HxWxD,
(45 x 92 mm) HxW panel cutout .
Weight
0.5 kg nominal (DMY-2030/2030-F/2035/2035-F/2036/2036-F)
0.6 kg nominal (DMY-2011/2011-F).
Warranty
One year.
presys
Process Indicator
and Totalizer Single
DMY-2030-TOT-Light
DMY-2030-TOT-F-Light
DMY-2030-TOT-Light: One universal input.
DMY-2030-TOT-F-Light: One frequency input.
Order Code
DMY
Model
2030-TOT-Light: mV, V, mA
input.
2030-TOT-F-Light: Frequency
input.
Output 1
0
1
2
3
4
5
6
None
4-20 mA
1-5 Vdc
0-10 Vdc
SPST Relay
Open Collector Voltage
Solid State Relay
Output 2
Same code as Output 1
Output 3
0
1
2
3
None
SPDT Relay
Open Collector Voltage
Solid State Relay
Output 4
Same code as Output 3
Power Supply
Communication
0
1
2
3
None
RS-232
RS-485
RS-422
* Explosion-proof box:
Dimensions: 310 x 310 x 200 mm (HxWxD)
Weight: 11 kg nominal
10
presys
Process Indicator
and Totalizer Dual
DMY-2030-TOT
DMY-2030-TOT-F
DMY-2030-TOT: Two inputs for mV, 4-20 mA, 1-5 Vdc and 0-10 Vdc.
DMY-2030-TOT-F: Two frequency inputs up to 30 kHz, from 300 mVpp to 30 Vpp.
8-digit display.
Specifications
Order Code
DMY
Model
Output 1
0
1
2
3
4
5
6
None
4-20 mA
1-5 Vdc
0-10 Vdc
SPST Relay
Open Collector Voltage
Solid State Relay
Output 2
Same code as Output 1
Output 3
0
1
2
3
None
SPDT Relay
Open Collector Voltage
Solid State Relay
Output 4
Same code as Output 3
Power Supply
1
2
3
4
Communication
0
1
2
3
None
RS-232
RS-485
RS-422
* Explosion-proof box:
Dimensions
Weight
11 kg nominal
Inputs
DMY-2030-TOT: Two configurable inputs 0-55 mV, 4-20 mA,
1-5 Vdc and 0-10 Vdc. 4-20 mA with input impedance of 250 .
>10 M up to 5 Vdc and 2 M above 5 Vdc.
DMY-2030-TOT-F: Two frequency inputs for signals up to 30 kHz,
from 300 mVpp to 30 Vpp.
Outputs
4-20 mA (750 maximum load), 1-5 Vdc or 0-10 Vdc analog
retransmitter. Up to 2 galvanically isolated modules to 300 Vac from
power supply and inputs. Up to 2 SPDT relay modules and up to
2 SPST relay modules, rated for 3A/220 Vac. Logic signal, open
collector transistor, 24 Vdc/40 mA maximum with isolation. Solid
state relay, 2A/250 Vac with isolation.
Serial Communication
RS-232 or RS-422/485 with 50 Vdc isolation. MODBUS-RTU
Communication Protocol.
Indication
8-digit red leds display (9 mm) for totalization and 5-digit for
indication. Can be configured together with the decimal point.
Totalization Range
0 to 99999999 configured together with the decimal point.
Configuration
By front-panel push-buttons and internal jumpers.
Sampling Rate
120 ms standard. One second display update rate.
Accuracy
0.1 % of full scale for TC, RTD, mA, mV and Vdc.
0.5 % of full scale for analog retransmitter output.
1 Display resolution for frequency input.
Square Root Extraction
0.5 % of reading, for input above 10 % of span. Programmable
Cut-off from 0 to 5 %.
2-wire Transmitter Power Supply
24 Vdc/50 mA maximum, isolated from output with short
circuit protection.
Span Temperature Coefficient
0.005 % of span / C using 25 C as the reference temperature.
Power Supply
75 to 264 Vac 50/60 Hz or 100 to 360 Vdc (10 W nominal);
24 Vac/dc (10 %); 12 Vdc (10 %).
Operating Range
0 to 60 C temperature and 90 % maximum relative humidity.
Dimensions
1/8 DIN (48 x 96 x 187 mm) HxWxD, (45 x 92 mm) HxW panel
cutout .
Weight
0.5 kg nominal.
Warranty
One year.
11
presys
12
presys
Order Code
DMY-
Model
2031-FCS: 2 x 4-digit display
2030-TOT-FCS: 1 x 8-digit
display
Output 1
0 - None
1 - SPST Relay
2 - Open Collector Voltage
3 - Solid State Relay
Output 2
Output 3
0 - None
1 - SPDT Relay
2 - Open Collector Voltage
3 - Solid State Relay
Output 4
Power Supply
1 - 75 to 264 Vac 50/60 Hz or 100 to 360 Vdc (any
polarity)
2 - 24 Vac or 24 Vdc (10 %)
3 - 12 Vdc (10 %)
4 -Others upon request
Communication
0 - None
1 - RS-232
2 - RS-485
3 - RS-422
Specifications
Inputs
Frequency inputs for signals up to 500 Hz, from 300 mVpp to
30 Vpp. DIN 19234 compliance for intrinsically safe NAMUR
sensors.
Outputs
SPST and SPDT relays rated for 3A/220 Vac.
Plug provided for up to 4 modules. Logic Signal, open collector
transistor, 24 Vdc/40 mA, maximum with isolation. Solid State Relay,
2A/250 Vac with isolation.
Serial Communication
RS-232 or RS-422/485 with 50 Vdc isolation. MODBUS-RTU
Communication Protocol.
Indication
DMY-2031-FCS: Two 4-digit red leds displays (9 and 14 mm).
DMY-2030-TOT-FCS: One 8-digit red leds display (9 mm).
Can be configured together with the decimal point.
Totalization Range
DMY-2031-FCS: 0 to 9999 counts.
DMY-2030-TOT-FCS: 0 to 99999999 counts.
Can be configured together with the decimal point.
Configuration
By front-panel push-buttons and internal jumpers.
2-wire Transmitter Power Supply
24 Vdc/50 mA maximum, isolated from output with
short circuit protection.
Power Supply
75 to 264 Vac 50/60 Hz or 100 to 360 Vdc (10 W nominal);
24 Vac/dc (10 %); 12 Vdc (10 %).
Operating Range
0 to 60 C temperature and 90 % maximum relative humidity.
Dimensions
1/8 DIN (48 x 96 x 187 mm) HxWxD, (45 x 92 mm) HxW
panel cutout.
Weight
0.5 kg nominal.
Warranty
One year.
*Explosion-proof box:
Dimensions
310 x 310 x 200 mm (HxWxD)
Weight
11 kg nominal
13
presys
Has characteristics that are common to Presys Line 2000: DMY-20XX, DCY-20XX and TY-20XX.
14
presys
Digital Indicator
for
Load Cell
DMY-2030-CC
Specially developed for use with load cell.
Input range from -30 mV to 30 mV.
Indication with peak hold, minimum and
maximum.
Order Code
DMY-2030-CC -
Output 1
0 - None
1 - 4-20 mA
2 - 1-5 Vdc
3 - 0-10 Vdc
4 - SPST Relay
5 - Open Collector Voltage
6 - Solid State Relay
Output 2
0 - None
1 - SPDT Relay
2 - Open Collector Voltage
3 - Solid State Relay
Output 3
Power Supply
Communication
0 - None
1 - RS-232
2 - RS-485
3 - RS-422
Specifications
Inputs
One -30 to 30 mV input.
Input impedance >10 M.
Outputs
4-20 mA (750 maximum load), 1-5 Vdc or 0-10 Vdc analog
retransmitter. Galvanically isolated module to 300 Vac from power
supply and inputs, one SPST relay module (replacing the analog output)
and up to 2 SPDT relay modules, rated for 3A/220 Vac. Logic signal,
open collector transistor, 24 Vdc/40 mA maximum with isolation.
Solid state relay, 2A/250 Vac with isolation.
Serial Communication
RS-232 or RS-422/485 with 50 Vdc isolation. MODBUS-RTU
Communication Protocol.
Indication
4 digit red leds display (14 mm).
Can be configured together with the decimal point.
Configuration
By front-panel push-buttons and internal jumpers.
Sampling Rate
64 ms standard.
Accuracy
0.1 % of full scale for inputs.
0.5 % of full scale for analog retransmitter output.
Span Temperature Coefficient
0.005 % of span / C using 25 C as the reference temperature.
Power Supply for load cell
10 Vdc/100 mA.
Power Supply
75 to 264 Vac 50/60 Hz or 100 to 360 Vdc
(10 W nominal); 24 Vac/dc (10 %); 12 Vdc (10 %).
Operating Ambient
0 to 60 C temperature and 90 % maximum relative humidity.
Dimensions
1/8 DIN (48 x 96 x 187 mm) HxWxD, (45 x 92 mm) HxW panel
cutout.
Weight
0.5 kg nominal.
Warranty
One year.
15
presys
16
presys
Order Code
DMY-2030-CV
Model
Output 1
0 - None
1 - 4-20 mA
2 - 1-5 Vdc
3 - 0-10 Vdc
4 - SPST Relay
5 - Open Collector Voltage
6 - Solid State Relay
Output 2
0 - None
1 - SPST Relay
2 - Open Collector Voltage
3 - Solid State Relay
Output 3
0 - None
1 - SPDT Relay
2 - Open Collector Voltage
3 - Solid State Relay
Output 4
Same code as Output 3
Power Supply
1 - 75 to 264 Vac 50/60 Hz or 100 to 360 Vdc (any
polarity)
2 - 24 Vac or 24 Vdc (10 %)
3 - 12 Vdc (10 %)
4 - Others, upon request
Communication
0 - None
1 - RS-232
2 - RS-485
3 - RS-422
Specifications
Inputs
Three configurable inputs for 4-20 mA, 1-5 Vdc.
250 input impedance for mA and >10 M
for 5 Vdc.
Outputs
4-20 mA (750 maximum load), 1-5 Vdc or 0-10 Vdc analog
retransmitter. Galvanically isolated module to 300 Vac from power
supply and inputs. Up to 2 SPST relay modules and up to 2 SPDT
relay modules, rated for 3A/220 Vac. Logic signal, open collector
transistor, 24 Vdc/40 mA maximum with isolation. Solid state relay,
2A/250 Vac with isolation.
Serial Communication
RS-232 or RS-422/485 with 50 Vdc isolation. MODBUS-RTU
Protocol
Indication
8-digit red leds display (9 mm) for totalization and 5 digits for
indication. Can be configured together with the decimal point.
Totalization
0 to 99999999. Can be configured together with the decimal point.
Configuration
By front-panel push-buttons and internal jumpers.
Sampling Rate
120 ms standard. One second display update.
Accuracy
0.1 % of full scale for mA and Vdc inputs.
0.5 % of full scale for analog retransmitter output.
Square Root Extraction
0.5 % of reading, for input above 10 % of span. Programmable
Cut-off from 0 to 5 %.
2-wire Transmitter Power Supply
24 Vdc/50 mA maximum, isolated from output with short circuit
protection
Span Temperature Coefficient
0.005 % of span / C using 25 C as the reference temperature.
Power Supply
75 to 264 Vac 50/60 Hz or 100 to 360 Vdc
(10 W nominal); 24 Vac/dc (10 %); 12 Vdc (10 %).
Operating Ambient
0 to 60 C temperature and 90 % maximum relative humidity.
Dimensions
1/8 DIN (48 x 96 x 187 mm) HxWxD, (45 x 92 mm) HxW panel
cutout.
Weight
0.5 kg nominal.
Warranty
One year.
*Explosion-proof box:
Dimensions
310 x 310 x 200 mm (HxWxD)
Weight
11 kg nominal
17
presys
DMY-2017
presys
Order Code
DMY -
Specifications
Model
2017-Light
2017
Input 1
Range
1 - 0 to 250 mmH2O
2 - 0 to 1 psi
3 - 0 to 5 psi
4 - 0 to 15 psi
5 - 0 to 30 psi
6 - 0 to 100 psi
7 - 0 to 250 psi
8 - 0 to 500 psi
9 - 0 to 1000 psi
10 - 0 to 3000 psi *
11 - 0 to 5000 psi *
Only
non-corrosive
gases
Fluids
compatible
with 316
stainless steel
Pressure Type
1 - Gauge
2 - Absolute
3 - Vacuum (0 to 1 atm)
Sensor Type
Input 2
Output 1
0 - None
1 - 4-20 mA
2 - 1-5 Vdc
3 - 0-10 Vdc
4 - SPST Relay
5 - Open Collector Voltage
6 - Solid State Relay
Output 2
Output 3
0 - None
1 - SPDT relay
2 - Open Collector Voltage
3 - Solid State Relay
Output 4
Power Supply
Communication
Inputs
DMY-2017-Light: One pressure input.
DMY-2017: One or two pressure inputs.
Input for gauge, absolute pressure or vacuum.
Ranges from 250 mmH2O to 5000 psi (gauge pressure).
Ranges from 15 psi to 1000 psi (Absolute pressure).
Ranges from 1 atm (Vacuum). Use with compressed air
and non-corrosive / conductive gases up to 5 psi.
Air or fluids compatible with 316 stainless steel above 5 psi.
DMY-2017: Auxiliar analog input (for simple version only),
configurable for thermocouple (J, K, T, E, R, S under
ITS-90), 0-55 mV, RTD under DIN 43760, 4-20 mA,
1-5 Vdc and 0-10 Vdc. 250 input impedance for mA,
>10 M up to 5 Vdc and 2 M above 5 Vdc.
Outputs
4-20 mA (750 maximum load), 1-5 Vdc or 0-10 Vdc
analog retransmitter. Up to 2 galvanically isolated modules
to 300 Vac from power supply and inputs. SPDT and SPST
relay modules, rated for 3A/220 Vac. Logic signal, open
collector transistor, 24 Vdc/40 mA maximum with isolation.
Solid state relay, 2A/250 Vac with isolation.
Note: Slot provided for up to 4 alarm modules
(taking the two slots of the analog outputs).
Serial Communication
RS-232 or RS-422/485 with 50 Vdc isolation.
MODBUS-RTU Communication Protocol.
Indication
4-digit red leds display (14 mm). Can be configured
together with the decimal point.
Engineering Units
psi, atm, inH2O, kgf/cm2, mH2O, mmH2O, inHg, mmHg,
cmHg, bar, mbar and kPa.
Configuration
By front-panel push-buttons and internal jumpers.
Sampling Rate
120 ms standard. One second display update rate.
Accuracy
1 % of full scale for 250 mmH2O range.
0.1 % of full scale for the other ranges.
0.1 % of full scale for TC, RTD, mA, mV and Vdc inputs.
0.5 % of full scale for analog retransmitter output.
750 maximum load.
2-wire Transmitter Power Supply
24 Vdc/50 mA maximum, isolated from output with
short circuit protection
Span Temperature Coefficient
0.01 % of span / C for pressure inputs.
0.005 % of span / C for auxiliar analog inputs.
Reference 25 C.
Power Supply
75 to 264 Vac 50/60 Hz or 100 to 360 Vdc
(10 W nominal); 24 Vac/dc (10 %); 12 Vdc (10 %).
Operating Range
0 to 60 C temperature and 90 % maximum relative
humidity.
Dimensions
1/4 DIN (96 x 96 x 187 mm) HxWxD, (92 x 92 mm) HxW
panel cutout.
Pneumatic / hydraulic connection
1/4" Union for plastic tubing for use with air or
1/4" Female NPT for use with other fluids.
Weight
1.0 kg nominal.
Warranty
One year.
0 - None
1 - RS-232
2 - RS-485
3 - RS-422
presys
DCY-2060-Light /
DCY-2060-F-Light
DCY-2050-Light /
DCY-2050-F-Light
DCY-2051-Light /
DCY-2051-F-Light
F-Light version for frequency inputs up to 30 kHz, from 300 mVpp to 30 Vpp.
Up to 2 universal output modules for 4-20 mA, 1-5 Vdc and 0-10 Vdc, one for control and
one for retransmission, relay, solid state relay and open collector voltage, isolated from inputs
and power supply.
Several optional:
- Up to 2 SPDT + 2 SPST relay alarm modules;
- RS-232 or RS-422/485 Communication;
20
presys
Order Code
DCY -
Model
Output 2
Output 3 (Alarm)
0 - None
1 - SPDT Relay
2 - Open Collector Voltage
3 - Solid State Relay
Output 4 (Alarm)
Power Supply
Communication
0 - None
1 - RS-232
2 - RS-485
3 - RS-422
Weight
11 kg nominal
Specifications
Inputs
DCY-2050-Light / 2051-Light / 2060-Light: Configurable input for
thermocouple (J, K, T, E, R, S under ITS-90), 0-55 mV, RTD Pt-100
under DIN43760, 4-20 mA, 1-5 Vdc and 0-10 Vdc. Input for remote
setpoint configurable for 4-20 mA, 1-5 Vdc and 0-10 Vdc. 250 input
impedance for mA, >10 M up to 5 Vdc and 2 M above 5 Vdc.
DCY-2050-F-Light / 2051-F-Light / 2060-F-Light: Frequency input for
signals up to 30 kHz, from 300 mVpp to 30 Vpp. DIN-19234 compliance
for intrinsecally safe NAMUR sensors.
Control Function
ON-OFF, PID, PID with AUTO-TUNE, Heating-cooling, Heating-cooling
proportional, Ratio, Remote Set point and programmable set
point.
Control Outputs
Analog 4-20 mA (750 maximum load), 1-5 Vdc or 0-10 Vdc.
One optional module galvanically isolated to 300 Vac from power supply
and inputs. SPST relay rated for 3A/220 Vac. Open collector transistor
(24 Vdc/40 mA maximum with isolation). Solid state relay (2A/250 Vac
with isolation).
Alarm Outputs
SPDT relay rated for 3A/220 Vac. Open collector transistor
(24 Vdc/40 mA maximum with isolation). Solid state relay (2A/250 Vac
with isolation).
Serial Communication
RS-232 or RS-422/485 with 50 Vdc isolation. MODBUS-RTU
Communication Protocol.
Indication
DCY-2050-Light / 2050-F-Light: Two 4-digit displays (9 mm).
DCY-2051-Light / 2051-F-Light: Two 4-digit displays (14 mm / 9 mm).
DCY-2060-Light / 2060-F-Light: Two 4-digit displays (14 mm).
Can be configured together with the decimal point.
Configuration
By front-panel push-buttons and internal jumpers.
Sampling Rate
130 ms standard. Half second display update rate.
Accuracy
0.1 % of full scale for TC, RTD, mA, mV and Vdc inputs.
0.5 % of full scale for analog retransmitter output.
1 display resolution for frequency input.
Linearization
0.1 C for RTD and 0.2 C for TC.
Square Root Extraction
0.5 % of reading, for inputs above 10 % of span.
Programmable Cut-off from 0 to 5 %.
Cold Junction Compensation
2.0 C at range from 0-60 C ambient temperature.
2-wire transmitter Power Supply
24 Vdc/50 mA maximum, isolated from output, with short circuit
protection.
Span Temperature Coefficient
0.005 % of span / C using 25 C as the reference temperature.
Power Supply
75 to 264 Vac 50/60 Hz or 100 to 360 Vdc
(10 W nominal); 24 Vac/dc (10 %); 12 Vdc (10 %).
Operating Range
0 to 60 C temperature and 90 % maximum relative humidity.
Dimensions
DCY-2050-Light/2050-F-Light: 1/8 DIN (96 x 48 x 187 mm) HxWxD,
(92 x 45 mm) HxW panel cutout.
DCY-2051-Light/2051-F-Light: 1/8 DIN (48 x 96 x 187 mm) HxWxD,
(45 x 92 mm) HxW panel cutout.
DCY-2060-Light/2060-F-Light: 1/4 DIN (96 x 96 x 187 mm) HxWxD,
(92 x 92 mm) HxW panel cutout.
Weight
0.5 kg nominal (DCY-2050-Light/2050-F-Light/2051-Light/2051-F-Light).
0.6 kg nominal (DCY-2060 Light/2060-F-Light).
Warranty
One year.
21
presys
DCY-2051 / DCY-2051-F
DCY-2060 / DCY-2060-F
DCY-2050 / DCY-2050-F
presys
Order Code
Specifications
DCY -
Model
Power Supply
1 - 75 to 264 Vac 50/60 Hz or 100 to 360 Vdc (any polarity)
2 - 24 Vac or 24 Vdc (10 %)
3 - 12 Vdc (10 %)
4 - Others, upon request
Communication
0 - None
1 - RS-232
2 - RS-485
3 - RS-422
Weight
11 kg nominal
Entradas
DCY-2050 / 2051 / 2060 / 2055: Configurable inputs for
thermocouple (J, K, T, E, R, S under ITS-90), 0-55 mV,
RTD Pt-100 under DIN43760, 4-20 mA, 1-5 Vdc and
0-10 Vdc. Input for remote setpoint configurable for
4-20 mA, 1-5 Vdc and 0-10 Vdc. 250 input impedance
for mA, >10 M up to 5 Vdc and 2 M above 5 Vdc.
DCY-2050-F / 2051-F / 2060-F:
Frequency inputs for signals up to 30 kHz, from 300 mVpp
to 30 Vpp. DIN-19234 compliance for intrinsecally safe
NAMUR sensors.
Control Functions
ON-OFF, PID, PID with AUTO-TUNE, Heating-cooling,
Ratio, Cascade, Remote Set point and programmable set point.
Control Outputs
Analog 4-20 mA (750 maximum load), 1-5 Vdc or 0-10 Vdc.
Up to two optional module galvanically isolated to 300 Vac from
power supply and inputs. SPST relay rated for 3A/220 Vac. Open
collector transistor (24 Vdc/40 mA maximum with isolation).
Solid state relay (2A/250 Vac with isolation).
Alarm Outputs
SPDT relay rated for 3A/220 Vac. Open collector transistor
(24 Vdc/40 mA maximum with isolation). Solid state relay
(2A/250 Vac with isolation).
Serial Communication
RS-232 or RS-422/485 with 50 Vdc isolation. MODBUS-RTU
Communication Protocol.
Indication
DCY-2050 / 2050-F: Two 4-digit displays (9 mm).
DCY-2051 / 2051-F: Two 4-digit displays (14 mm / 9 mm).
DCY-2060 / 2060-F: Two 4-digit displays (14 mm).
DCY-2055: Without local indication.
Can be configured together with the decimal point.
Configuration
DCY-2050 / DCY-2051 / DCY-2060: By front-panel push-buttons
and internal jumpers. DCY-2055: Via serial communication or
MCY-25 configuration module.
Sampling Rate
130 ms standard. Half second display update rate.
Accuracy
0.1 % of full scale for TC, RTD, mA, mV and Vdc inputs.
0.5 % of full scale for analog retransmitter output.
1 display resolution for frequency input.
Linearization
0.1 C for RTD and 0.2 C for TC.
Square Root Extraction
0.5 % of reading, for inputs above 10 % of span.
Programmable Cut-off from 0 to 5 %.
Cold Junction Compensation
2.0 C at range from 0-60 C ambient temperature.
2-wire transmitter Power Supply
24 Vdc/50 mA maximum, isolated from output, with short circuit
protection.
Span Temperature Coefficient
0.005 % of span / C for auxiliar input .Reference temperature: 25 C.
Power Supply
75 to 264 Vac 50/60 Hz or 100 to 360 Vdc
(10 W nominal); 24 Vac/dc (10 %); 12 Vdc (10 %).
Operating Range
0 to 60 C temperature and 90 % maximum relative humidity.
Dimensions
DCY-2050 / 2050-F: 1/8 DIN (96 x 48 x 187 mm) HxWxD,
(92 x 45 mm) HxW panel cutout.
DCY-2051 / 2051-F: 1/8 DIN (48 x 96 x 187 mm) HxWxD,
(45 x 92 mm) HxW panel cutout.
DCY-2060 / 2060-F: 1/4 DIN (96 x 96 x 187 mm) HxWxD,
(92 x 92 mm) HxW panel cutout.
DCY-2055: (140 x 53 x 175 mm) HxWxD.
Weight
0.5 kg nominal (DCY-2050/2051)
0.6 kg nominal (DCY-2060/2055)
Warranty
One year.
23
presys
3 Elements
Digital Controller
for Boiler Level
DCY-2050-LC / DCY-2051-LC
DCY-2060-LC
3 Elements control: boiler level, water flow and
steam flow.
Three standard inputs for 4-20 mA and 1-5 Vdc,
configurable.
Order Code
DCY -
-LC -
Model
Output 3 (Alarm)
0 - None
1 - SPDT Relay
2 - Open Collector
3 - Solid State Relay
Output 4 (Alarm)
Power Supply
Communication
0 - None
1 - RS-232
2 - RS-485
3 - RS-422
24
presys
Auto/Manual
Station
DCY-2058 /
DCY-2059
Two standard inputs for 4-20 mA, 1-5 Vdc and
0-10 Vdc.
Up to 2 analog outputs for 4-20 mA, 1-5 Vdc
and 0-10 Vdc, galvanically isolated from inputs
and power supply.
Configuration stored in non-volatile memory.
Order Code
DCY-
Model
Version
1 - Single Loop
2 - Dual Loop
Power Supply
Communication
0 - None
1 - RS-232
2 - RS-485
3 - RS-422
Specifications
Inputs
Two configurable inputs for 4-20 mA, 1-5 Vdc and 0-10 Vdc, selected by the user.
250 input impedance for mA, >10 M for 5 Vdc and 2 M above 5 Vdc.
Outputs
Analog 4-20 mA (750 maximum load), 1-5 Vdc or 0-10 Vdc. Up to 2 optional
modules galvanically isolated to 300 Vac from power supply and inputs
Serial Communication
RS-232 or RS-422/485 with 50 Vdc isolation. MODBUS-RTU
Communication Protocol.
Indication
DCY-2058: Two 4-digit red leds display (9 mm).
DCY-2059: Two 4-digit red leds display (9 mm and 14 mm).
Can be configured together with the decimal point.
Configuration
By front-panel push-buttons and internal jumpers.
Sampling Rate
Simple Station: 64 ms standard. Half second display update rate.
Dual Station: 120 ms standard. 0.6 seconds display update rate.
Accuracy
0.5 % of full scale for input indication and output generation.
2-wire transmitter Power Supply
24 Vdc/50 mA maximum, isolated from output, with short circuit protection.
Power Supply
75 to 264 Vac 50/60 Hz or 100 to 360 Vdc
(10 W nominal); 24 Vac/dc (10 %); 12 Vdc (10 %).
Operating Range
0 to 60 C temperature and 90 % maximum relative humidity.
Dimensions
DCY-2058: 1/8 DIN (96 x 48 x 187 mm) HxWxD,
(92 x 45 mm) HxW panel cutout.
DCY-2059: 1/8 DIN (48 x 96 x 187 mm) HxWxD,
(45 x 92 mm) HxW panel cutout.
Weight
0.5 kg nominal.
Warranty
One year.
25
presys
Ranges: 0 to 250 mmH2O, 1 psi, 5 psi, 15 psi, 30 psi, 100 psi, 250 psi, 500 psi and 1000 psi.
Gauge or absolute pressure and vacuum.
Auxiliar universal input for RTD, thermocouple, 0-55 mV, 4-20 mA, 1-5 Vdc and 0-10 Vdc.
Mounting options in weather-proof box.
High control capacity, performing the functions of:
- Auto-tune.
- ON-OFF, P-PI-PD-PID, ratio, cascade control.
- Remote Setpoint, programmable set point up to 10 segments
- Auto/manual station.
- Up to 2 analog output modules 4-20 mA, 1-5 Vdc and 0-10 Vdc.
- Up to 3 alarm modules with SPDT and SPST relays.
- Front Aspersion-proof.
- RS-232 or RS-422/485 Communication.
Ideal for
Pressure and
Temperature
Control
in
Reactors
75 to 264 Vac, 50/60 Hz or 100 to 360 Vdc; 24 Vac/dc and 12 Vdc power supply,
as ordered.
presys
Order Code
DCY-2057 -
Input
Range
1 - 0 to 250 mmH2O
*
2 - 0 to 1 psi
3 - 0 to 5 psi
4 - 0 to 15 psi
5 - 0 to 30 psi
6 - 0 to 100 psi
**
7 - 0 to 250 psi
8 - 0 to 500 psi
9 - 0 to 1000 psi
Pressure Type
1 - Gauge
2 - Absolute
3 - Vacuum (0 to 1 atm)
Sensor Type
Output 1 (Control)
0 - None
1 - 4-20 mA
2 - 1-5 Vdc
3 - 0-10 Vdc
4 - SPST Relay
5 - Open Collector Voltage
6 - External Solid State Relay
Output 2 (Alarm)
Output 3 (Alarm)
0 - None
1 - SPDT Relay
2 - Open Collector Voltage
3 - Solid State Relay
Output 4 (Alarm)
Power Supply
Specifications
Inputs
Input for vacuum, gauge or absolute pressure.
Ranges from 250 mmH2O to 1000 psi (Gauge Pressure).
Ranges from 15 psi to 1000 psi (Absolute Pressure). Range up to
1 atm (Vacuum). Use with compressed air and non-corrosive /
condutive gases, up to 5 psi. Above 5 psi, use with liquids and
fluids compatible with 316 stainless steel. Auxiliar analog input for TC
(J, K, T, E, R, S under ITS-90), 0-55 mV, RTD Pt-100, under
DIN-43760, 4-20 mA, 1-5 Vdc and 0-10 Vdc. 250 input impedance
for mA, >10 M up to 5 Vdc and 2 M above 5 Vdc.
Control Functions
ON-OFF, PID, PID with AUTO-TUNE, Ratio, Cascade and Remote
Set point.
Control Output
Analog 4-20 mA (750 maximum load), 1-5 Vdc or 0-10 Vdc.
Up to 2 optional module galvanically isolated to 300 Vac from power
supply and inputs. SPST Relay rated for 3A/220 Vca. Open collector
transistor (24 Vdc/40 mA maximum with isolation). Solid state relay
(2A/250 Vac maximum with isolation).
Alarm Outputs
SPDT relay rated for 3A/220 Vac. Open Collector Transistor (24 Vdc/40 mA
maximum with isolation). Solid state relay (2A/250 Vac with isolation).
Serial Communication
RS-232 or RS-422/485 with 50 Vdc isolation. MODBUS-RTU
Communication Protocol.
Indication
Two 4-digit red leds displays (14 mm) which can be configured together
with the decimal point.
Configuration
By front-panel push-buttons and internal jumpers.
Sampling Rate
130 ms standard. Half second display update rate.
Accuracy
1 % of full scale for the range of 250 mmH2O.
0.1 % of full scale for the other pressure ranges.
0.1 % of full scale for TC, RTD, mA, mV and Vdc inputs.
0.5 % of full scale for analog retransmitter output, 750 maximum load .
Linearization
0.1 C for RTD and 0.2 C for TC.
Square Root Extraction
0.5 % of reading, for inputs above 10 % of span.
Programmable Cut-off from 0 to 5 %.
Cold Junction Compensation
2.0 C at range from 0-60 C ambient temperature.
2-wire transmitter Power Supply
24 Vdc/50 mA maximum, isolated from output, with short circuit
protection.
Span Temperature Coefficient
0.005 % of span / C for auxiliar analog input.
0.01 % of span / C for pressure inputs.
Reference temperature: 25 C
Power Supply
75 to 264 Vac 50/60 Hz or 100 to 360 Vdc
(10 W nominal); 24 Vac/dc (10 %); 12 Vdc (10 %).
Operating Range
0 to 60 C temperature and 90 % maximum relative humidity.
Dimensions
1/4 DIN (96 x 96 x 187 mm) HxWxD, (92 x 92 mm) HxW panel cutout.
Weight
1.0 kg nominal.
Warranty
One year.
Communication
0 - None
1 - RS-232
2 - RS-485
3 - RS-422
27
presys
Universal
Smart
Transmitter
TY-2090 /
TY-2090-F
Transmitter and / or Alarm Monitor in one instrument, it may have up to four alarm modules.
TY-2090: Two universal standard inputs for RTD, TC, 0-55 mVdc, 4-20 mA, 1-5 Vdc and 0-10 Vdc.
TY-2090-F: Two frequency inputs, up to 30 kHz, from 300 mVpp to 30 Vpp.
One or two universal output for 4-20 mA, 1-5 Vdc, 0-10 Vdc, isolated from inputs.
Programmable via serial communication or through portable configurator.
Linearization for RTD and TC. Square root extraction.
Configuration stored in non-volatile memory.
DIN rail or surface assembly.
RS-232 or RS-422/485 Communication (optional).
28
presys
Order Code
TY -
Model
2090: Universal Inputs
2090-F: Frequency Inputs
Output 1
0 - None
1 - 4-20 mA
2 - 1-5 Vdc
3 - 0-10 Vdc
4 - SPST Relay
5 - Open Collector Voltage
6 - Solid State Relay
Output 2
Output 3
0 - None
1 - SPDT Relay
2 - Open Collector Voltage
3 - Solid State Relay
Output 4
Power Supply
1 - 75 to 264 Vac 50/60 Hz or 100 to 360 Vdc (any
polarity)
2 - 24 Vac or 24 Vdc (10 %)
3 - 12 Vdc (10 %)
4 - Other, upon request
Communication
0 - None
1 - RS-232
2 - RS-485
3 - RS-422
Specifications
Inputs
TY-2090: Configurable inputs for thermocouple (J, K, T, E,
R, S under ITS-90), 0-55 mV, RTD Pt-100 under DIN 43760,
4-20 mA, 1-5 Vdc and 0-10 Vdc. 250 input impedance for mA,
>10 M up to 5 Vdc and 2 M above 5 Vdc.
TY-2090-F: Frequency inputs for signals up to 30 kHz, from
300 mVpp to 30 Vpp. DIN-19234 compliance for intrinsically safe
NAMUR sensors.
Outputs
4-20 mA (750 maximum load), 1-5 Vdc or 0-10 Vdc analog
retransmitter. Up to 2 galvanically isolated module to 300 Vac
from power supply and inputs. Up to 2 SPST relay modules and
up to 2 SPDT relay modules, rated for 3A/220 Vac. Logic signal,
open collector transistor, 24 Vdc/40 mA maximum with isolation.
Solid state relay, 2A/250 Vac with isolation.
Serial Communication
RS-232 or RS-422/485 with 50 Vdc isolation. MODBUS-RTU
Communication Protocol.
Configuration
Via serial communication or MCY-20 configuration module.
Sampling Rate
120 ms standard.
Accuracy
0.1 % of full scale for TC, RTD, mA, mV and Vdc inputs, with
acquisition via RS-232 or RS-422/485 communication.
0.2 % of full scale for analog output and maximum load of 750.
1 display resolution for frequency input.
Linearization
0.1 C for RTD and 0.2 C for TC.
Square Root Extraction
0.5 % of reading, for inputs above 10 % of span.
Programmable Cut-off from 0 to 5 %.
Cold Junction Compensation
2.0 C at range from 0-60 C ambient temperature.
2-wire transmitter Power Supply
RS-232 or RS-422/485 with 50 Vdc isolation. MODBUS-RTU
Communication Protocol.
Span Temperature Coefficient
0.005 % of span / C using 25 C as the reference temperature
for acquisition by RS-232 or RS-422/485.
0.015 % of span / C using 25 C as the reference temperature
for analog output.
Power Supply
75 to 264 Vac 50/60 Hz or 100 to 360 Vdc (any polarity)
(10 W nominal); 24 Vac/dc (10 %); 12 Vdc (10 %).
Operating Range
0 to 60 C temperature and 90 % maximum relative humidity.
Dimensions
(140 x 53 x 175 mm) HxWxD.
Weight
0.5 kg nominal.
Warranty
One year.
* Explosion-proof box:
Dimensions
310 x 310 x 200 mm (HxWxD)
Weight
11 kg nominal
29
presys
Pressure to
Current
Converter (P/I)
TY-1110-DIN
Converts pressure signal normally 3 to 15 psi for
signal 4 to 20 mA, two-wire system using
semiconductor device (solid state).
Order Code:
TY-1110-DIN
Model
Input
3/15 - 3 to 15 psig.
Other values, upon request.
Note: Values within the maximum and minimum
limits of span, for absolute pressure or gauge.
Output
4/20 - 4 to 20 mAdc.
Power Supply
24 - 24 Vdc (2-wire system).
Connection
01 - Union for " flexible hose.
Code Example
TY-1110-DIN 3/15 4/20 24 01.
Defines a converter TY-1110-DIN pressure to current of input
3-15 psig and output 4-20 mAdc with 24Vdc power supply
and pneumatic connections type union for " flexible hose.
30
Specifications
Ranges
0 to 250 mmH2O minimum.
0 to 100 psig / psia maximum.
Pressure Type
Gauge or Absolute.
Accuracy
0.25 % of span.
Span Temperature Coefficient
0.05 % / C for process temperature variation.
0.01 % / C for ambient temperature variation.
Operating Range
-5 to + 60 C.
Overpressure
Up to two times the full scale pressure.
Power Supply
14 Vdc minimum; 45 Vdc maximum (2-wire system).
Pneumatic Connection
Union for flexible hose.
Case
Extruded anodized aluminum.
Dimensions
91 x 44 x 150 mm nominal (HxWxD).
Weight
0.5 kg nominal.
Warranty
One year.
Dimensional
presys
Electropneumatic
Converter
(I/P) Weather-proof
TY-1125-TEM
Model with weather-proof box for field mounting.
Specifications
Order Code:
TY-1125-TEM
Model
Input
4/20 - 4 to 20 mAdc.
10/50 - 10 to 50 mAdc.
Output
3/15 - 3 a 15 psi.
3/27 - 3 a 27 psi.
Accessories
Y1
Y3
Y4
Y5
Y6
Code Example
TY-1125 - TEM - 4/20 - 3/15 - Y1.
Defines a current to pressure converter for mounting in 2 inch
tube, in weather-proof box with 4-20 mA input and 3-15 psi
output.
Air Supply
1.6 scfm.
Pneumatic Supply
20 psi for 3-15 psi output, 30 psi maximum.
37 psi for 3-27 psi output, 40 psi maximum.
Air Demand
0.08 scfm.
Accuracy
0.5 % of span.
Repeatability
0.25 % of span.
Linearity
Less than or equal to 0.5%.
Hysteresis
Less than or equal to 0.2 %.
Temperature
-40 C + 80 C.
Connection
Cable gland Pg 9 (cable diameter: 4-10 mm) electrical part,
1/4 NPT pneumatic part.
Warranty
One year.
Dimensional
31
presys
32
presys
Simple to install, easy to use.
Specifications
Process monitoring through trend charts and circular;
Allows bargraphs viewing;
View data saved in disk or database;
Allows programming, collection and acquisitions viewing together
with the DMY-2015-DLY / TY-2095-DLY;
Allows online configuration of the Line 2000 instruments,
backup and configuration recovery;
MODBUS (RS-232/TCP) Communication Protocol;
Data export to spreadsheet;
Generates and saves alarm events;
It has user access control system.
COMFYS-2.2.
Allows remote configuration of the Line 2000 Presys instruments via
MODBUS RTU / TCP (requires converter);
It also allows the reading and storage of an instrument configuration,
as well as the subsequent reloading of it.
Available as a free download for use together with
Presys Instruments in our website.
Compatible with Windows XP or higher 32/64 bits.
33
presys
Multi-Loop Data-Logger
Module
DMY-2015-DLY
Available inputs for DMY-2015-DLY and TY-2095-DLY:
- 12 thermocouple inputs.
- 8 RTD inputs.
- 12 current inputs 4-20 mA.
- 12 voltage inputs 1-5 Vdc.
- Combinations of two types of input.
TY-2095-DLY
Data Logger function for storage of up to
256 000 readings.
ACK button.
34
presys
Order Code
Model
DMY-2015-DLY
TY-2095-DLY
Inputs
0 - 12 thermocouples
1 - 8 RTD
2 - 6 thermocouples and 4 RTD
3 - 12 current mA
4 - 12 voltage V
5 - 6 thermocouples and 6 current mA
6 - 6 thermocouples and 6 voltage V
7 - 6 current mA and 6 voltage V
8 - 6 current mA and 4 RTD
9 - 6 voltage V and 4 RTD
Output 1
0 - None
1 - SPDT Relay
2 - Open Collector Voltage
3 - Solid State Relay
Output 2
Power Supply
1 - 75 to 264 Vac 50/60 Hz or 100 to 360 Vdc (any
polarity)
2 - 24 Vac or 24 Vdc (10 %)
3 - 12 Vdc (10 %)
4 - Other, upon request
Communication
0 - None
1 - RS-232
2 - RS-485
3 - RS-422
Specifications
Inputs
Thermocouple (J, K, T, E, R, S under ITS - 90).
RTD Pt-100 under DIN 43760.
4-20 mA, 250 input impedance.
1-5 Vdc, input impedance >10 M.
Outputs
Two SPDT relay modules rated for 3A/220 Vac.
Logic signal, open collector transistor, 24 Vdc/40 mA
maximum with isolation. Solid state relay,
2A/250 Vac with isolation.
Serial Communication
RS-232 or RS-422/485 with 50 Vdc isolation.
MODBUS-RTU Communication Protocol.
Indication
DMY-2015-DLY: 4-digit red leds display (14 mm),
that can be configured together with the decimal point.
TY-2095-DLY: without local indication.
Configuration
DMY-2015-DLY: by front panel push buttons.
TY-2095-DLY: through the MCY-25 portable configurator.
Sampling Rate
660 ms standard, for all inputs. One second display update rate.
Accuracy
0.1 % of full scale for TC, RTD, mA, and Vdc.
Linearization
0.1 C for RTD and 0.2 C for TC.
Square Root Extraction
0.5 % of reading, for input above 10 % of span.
Programmable Cut-off from 0 to 5 %.
Cold Junction Compensation
2.0 C in ambient temperature range from 0 to 60 C.
Span Temperature Coefficient
0.005 % of span / C using 25 C as the reference temperature.
Power Supply
75 to 264 Vac 50/60 Hz or 100 to 360 Vdc
(10 W nominal); 24 Vac/dc (10 %); 12 Vdc (10 %).
Operating Range
0 to 60 C temperature and 90 % maximum relative humidity.
Dimensions
DMY-2015-DLY: 1/4 DIN (96 x 96 x 187 mm) HxWxD, (92 x 92 mm) HxW
panel cutout.
TY-2095-DLY: (140 x 93 x 173 mm) HxWxD.
Weight
0.7 kg nominal.
Warranty
One year.
35
presys
Data
Acquisition
Module
TY-2095 and
TY-2095-PB
Available models:
- 12 thermocouple inputs.
- 8 RTD inputs.
- 12 current 4-20 mA inputs.
- 12 voltage 1-5 Vdc inputs.
- Combination of two input types.
presys
Order Code
Model
TY-2095
TY-2095-PB
Inputs
0 - 12 thermocouples
1 - 8 RTD
2 - 6 thermocouples and 4 RTD
3 - 12 current mA
4 - 12 voltage V
5 - 6 thermocouples and 6 current mA
6 - 6 thermocouples and 6 voltage V
7 - 6 current mA and 6 voltage V
8 - 6 current mA and 4 RTD
9 - 6 voltage V and 4 RTD
Output 1
0 - None
1 - SPDT Relay
2 - Open Collector Voltage
3 - Solid State Relay
Output 2
Same code as Output 1
Power Supply
1 - 75 to 264 Vac 50/60 Hz or 100 to 360 Vdc (any
polarity)
2 - 24 Vac or 24 Vdc (10 %)
3 - 12 Vdc (10 %)
4 - Other, upon request
Communication
0 - None
1 - MODBUS (RS-232)*
2 - MODBUS (RS-485)*
3 - MODBUS (RS-422)*
4 - PROFIBUS DP-V0 (RS-485)**
Specifications
Inputs
Thermocouple (J, K, T, E, R, S under ITS - 90).
RTD Pt-100 under DIN 43760.
4-20 mA with input impedance of 250 .
1 to 5 Vdc with input impedance >10 M.
Outputs
Up to 2 SPDT relays rated for 3A/220 Vac.
Logic signal, open collector transistor, 24 Vdc/40 mA
maximum with isolation. Solid state relay,
2A/250 Vac with isolation.
Serial Communication
TY-2095: RS-232 or RS-422/485. MODBUS-RTU
Communication Protocol.
TY-2095-PB: PROFIBUS DP-V0: RS-485.
Indication
Without local indication. Maximum range from -999 to 9999
viewed through the MCY-25 Configuration Module.
Totalization
Totalization of eight voltage or current inputs ranging from
0 to 9999, configured with the decimal point.
Configuration
Through MCY-25 portable configurator.
Sampling Rate
480 ms standard, for all inputs. One second display update rate.
Accuracy
0.1 % of full scale for TC, RTD, mA, Vdc.
Linearization
0.1 C for RTD and 0.2 C for TC.
Square Root Extraction
0.5 % of reading, for input above 10 % of span.
Programmable Cut-off from 0 to 5 %.
Cold Junction Compensation
2.0 C in ambient temperature range from 0 to 60 C.
Span Temperature Coefficient
0.005 % of span / C using 25 C as the reference
temperature.
Power Supply
75 to 264 Vac 50/60 Hz or 100 to 360 Vdc
(10 W nominal); 24 Vac/dc (10 %); 12 Vdc (10 %).
Operating Range
0 to 60 C temperature and 90 % maximum relative humidity.
Dimensions
140 x 93 x 173 mm HxWxD.
Weight
0.7 kg nominal.
Warranty
One year.
37
presys
Accessories
Analog Output Module MSAN-20
Generates 4-20 mA, 1-5 Vdc, 0-10 Vdc signals. For use as a control
output or retransmitter output of the process variable.
RS-232 Communication
Module MCOM RS232
RS-232 interface for communication for connecting
one single instrument to the computer. Maximum
distance 15 meters.
38
presys
RS-485Communication
Module MCOM RS-485
RS-485 Communication Interface, to connect up to
31 instruments in a network with the computer.
Maximum distance 1200 meters.
External Thyristor
Power Unit MTY-48D10
Used for controlling loads up to 10 Aac. It is necessary
that the instrument has the Open Collector Module MSD-20.
Other types of thyristor unit are available on request.
Configurators
MCY-20/MCY-25/MCY-55
For use with instruments TY-2090, TY-2095,
DCY-2055. It allows its configuration by
keyboard and display.
Converter Unit
RS-232/485UNICONV232/485
Used for a network connection of the
instruments to the computer serial port.
39
Explosion-proof
Panel for
Line 2000
Instruments
The Presys Explosion-proof box was especially developed for instruments used in the
Industrial Process as Indicators, Controllers and Transmitters.
Main Features:
- Applicable in area of explosive atmosphere, consisting of combustible gases,
classified as Zone 1 Group IIB.
- Fully protected against dust and water jets.
- Certificate of Conformity to Electrical Equipment for Potentially Explosive Atmospheres,
by IEE-USP and TV RHEINLAND, with the marks Ex d IIB T6 Gb IP66.
- Fully programmable by the front panel push-buttons, via serial communication or
through portable configurator as specified model.
40
presys
Explosion-proof Models with Horizontal Display
DMY-2030, DMY-2030-F, DMY-2030-TOT, DMY-2030-TOT-F, DMY-2030-Light, DMY-2030-F-Light, DMY-2030-TOT-Light,
DMY-2030-TOT-F-Light, DMY-2030-CC, DMY-2030-CV, DMY-2030-TOT-FCS, DMY-2031-FCS, DMY-2036, DMY-2036-F,
DMY-2011, DMY-2011-F, DMY-2015, DMY-2015-PB, DCY-2051, DCY-2051-F, DCY-2051-Light, DCY-2051-F-Light,
DCY-2051-LC, DCY-2059, DCY-2060, DCY-2060-F, DCY-2060-Light, DCY-2060-F-Light, DCY-2060-LC.
Explosion-proof Models with Vertical Display
DMY-2035, DMY-2035-F, DCY-2050, DCY-2050-F, DCY-2050-Light, DCY-2050-F-Light, DMY-2050-LC, DCY-2058.
200mm
140mm
15mm(x4)
310mm
275mm
A M
Horizontal Display
Vertical Display
Without Display
POSITION
80mm
NOMINAL
(NPT)
3/4"
1"
1.1/4"
1.1/2"
C
ORDER CODE EXAMPLE: EXPLOSION-PROOF INDICATOR
CHOSEN POSITIONS
MODEL
41
presys
Dimensional
Drawings
GND Terminal
26.5 mm
148.5 mm
140 mm
91 mm
130.5 m m
Terminal block
4.5 mm
175 mm
53 mm
Side View
Front View
26.5 mm
146.5 mm
173 mm
Side View
42
93 mm
Front View
140 mm
91 mm
GND Terminal
4.5 mm
130.5 mm
Terminal block
presys
1/4 DIN Models
DMY-2011, DMY-2015, DMY-2015-PB, DMY-2015-DLY, DMY-2017,
DMY-2017-Light, DCY-2057, DCY-2060, DCY-2060-LC and DCY-2060-Light
91 m m
96 mm
12 mm
26,5
mm
148.5 mm
Front View
GND Terminal
187 mm
92 mm - 0.0
+0.8
Side View
Panel Cutout(*)
148.5 mm
187 mm
26.5
mm
GND Terminal
Side View
Front View
+0.6
92 m m - 0.0
+0.8
45 mm - 0.0
44 mm
12 mm
96 mm
91 mm
48 mm
Vista Superior
(*)Maximum panel thickness: 10 mm
presys
1/8 DIN Models with Horizontal Orientation
DMY-2030, DMY-2030-Light, DMY-2030-TOT, DMY-2030-TOT-Light, DMY-2030-CC,
DMY-2030-CV, DMY-2031-FCS, DMY-2030-TOT-FCS, DCY-2051, DCY-2051-LC,
DCY-2051-Light, DCY-2059 and DMY-2036
48 mm
44 mm
96 mm
Side View
Front View
+0.8
- 0.0
45 mm
+0.6
- 0.0
91 mm
92 mm
Panel Cutout(*)
26.5
mm
148.5 mm
12 mm
GND Terminal
187 mm
Upper View
Model: DMY-2032
20 mm
140 mm
26.5
mm
GND Terminal
130 mm
91 mm
235 mm
Front View
186.5 mm
92 mm - 0.0
+0.8
Side View
44
Panel Cutout(*)
presys
Weather-proof Models - IP 66
180 mm
INSTRUMENT FIXING
SUPPORT
TRANSPARENT
COVER
155 mm
DISPLAY
(1/8 or 1/4 DIN)
PR E SYS
LD2
245 mm
270 mm
LD1
INSTRUMENT
(1/8 OR 1/4 DIN)
SIDE VIEW
FRONTAL
VIEW
45 mm
171 mm
126 mm
UPPER VIEW
CLAMP
2 TUBE
CLAMP
2 TUBE
223.5 mm
SUPPORT
223.5 mm
SUPPORT
ASSEMBLY WITH 2 " TUBE SUPPORT
HORIZONTAL AND VERTICAL
45
presys
HART Field
Communicator
FCY-15
46
Instrumentos e Sistemas
EMENT SYS
AG
Calibrao
NBR ISO/IEC
17025
QUA ITY
L
CAL 0193
M
TE
PRESYS
MA
N
Instrumentation and
Process Control
OCP 0004
EF-0241-01