Process Control Presys

Download as pdf or txt
Download as pdf or txt
You are on page 1of 50

R

Instrumentos e Sistemas

EMENT SYS
AG

Calibrao
NBR ISO/IEC
17025

QUA ITY
L

CAL 0193

M
TE

PRESYS

Rua Luiz da Costa Ramos, 260


So Paulo - SP - 04157-020
Tel: (11) 3056.1900
Fax: (11) 5073.3366
http://www.presyscorp.com
E-mail: vendas@presys.com.br

MA
N

Instrumentation and
Process Control

OCP 0004

EF-0241-01

presys
TABLE OF CONTENTS

page

INDICATORS
Digital Multi-point Indicator - DMY-2015 / DMY-2015-PB (Profibus)

02

Universal Digital Indicator - Single - DMY-2030-Light

04

Frequency Digital Indicator - Single - DMY-2030-F-Light

06

Universal Process Indicator - Dual - DMY-2030 / DMY-2030-F / DMY-2011 / DMY-2011-F / DMY-2035 /


DMY-2035-F / DMY-2036 / DMY-2036-F

08

Process Indicator and Totalizer - Single - DMY-2030-TOT-Light / DMY-2030-TOT-F-Light

10

Process Indicator and Totalizer - Dual - DMY-2030-TOT / DMY-2030-TOT-F

11

Process Counter - Dual - DMY-2030-TOT-FCS / DMY-2031-FCS

12

Universal Process Indicator (Large Digits) - DMY-2032 / DMY-2032-F

14

Digital Indicator for Load Cell - DMY-2030-CC

15

Flow Calculator - DMY-2030-CV

16

Pressure Indicator - Single or Dual - DMY-2017-Light / DMY-2017

18

CONTROLLERS
Universal Process Controllers - Single Loop - DCY-2050-Light / DCY-2050-F-Light / DCY-2051-Light /
DCY-2051-F-Light / DCY-2060-Light / DCY-2060-F-Light

20

Universal Process Controllers - Dual Loop - DCY-2050 / DCY-2050-F / DCY-2051 / DCY-2051-F /


DCY-2060 / DCY-2060-F / DCY-2055

22

3 Elements Digital Controller for Boiler Level - DCY-2050-LC / DCY-2051-LC / DCY-2060-LC

24

Auto/Manual Station - DCY-2058 / DCY-2059

25

Pressure Controller - DCY-2057

26

TRANSMITTERS / CONVERTERS
Universal Smart Transmitter - TY-2090 / TY-2090-F

28

Pressure to Current Converter (P/I) - TY-1110-DIN

30

Eletropneumatic Converter (I/P) Weather-proof - TY-1125-TEM

31

VIRTUAL RECORDER / DATA LOGGER


Virtual Recorder VR-2000 - 3.3

32

Multi-Loop Data-Logger Module - DMY-2015-DLY / TY-2095-DLY

34

Data Acquisition
Data Acquisition Module - TY-2095 / TY-2095-PB (Profibus)

36

ACCESSORIES / DIMENSIONALS
Internal Optional Modules / Configurators

38

Explosion-proof Panel

40

Dimensional Drawings

42

HART CONFIGURATOR
HART Field Communicator - FCY-15

46

presys

Digital Multi-point
Indicator
DMY-2015 and
DMY-2015-PB

Models available for:


- 12 THERMOCOUPLE INPUTS.
- 8 RTD INPUTS.
- 12 CURRENT INPUTS 4-20 mA.

- 12 VOLTAGE INPUTS 1-5 Vdc.


- COMBINATION OF 2 INPUT TYPES.

Totalization function.
Many optional Modules are available:
- Up to 2 SPDT relays alarm modules.
- One retransmitter output 1-5 Vdc, 4-20 mA
or 0-10 Vdc, which can retransmit any input signal or the
mean of selected channels configuration. (item upon request).
- Galvanic isolation between inputs, outputs and power supply.
- Isolation between inputs is also available upon request.
- RS-232, RS-422/485 Communication (MODBUS RTU Protocol) or PROFIBUS (DP-V0)*.
- Aspersion-proof front-panel.

Configurable display for up to 4-digit of high visibility for the process variable indication. Another
display shows which channel is being displayed. Still has twelve LEDs that may indicate alarm
states for each channel.

*Only available for DMY-2015-PB model.


2

presys
Order Code

Model
DMY-2015
DMY-2015-PB

Inputs
0 - 12 TC inputs
1 - 8 RTD inputs
2 - 6 TC and 4 RTD inputs
3 - 12 current inputs
4 - 12 voltage inputs
5 - 6 TC and 6 current inputs
6 - 6 TC and 6 voltage inputs
7 - 6 current and 6 voltage inputs
8 - 6 current and 4 RTD inputs
9 - 6 voltage and 4 RTD inputs

Output 1
0 - None
1 - SPDT Relay
2 - Open Collector Voltage
3 - Solid State Relay

Output 2
Same code as output 1

Power Supply
1 - 75 to 264 Vac 50/60 Hz or 100 to 360 Vdc (any polarity)
2 - 24 Vac or 24 Vdc (10 %)
3 - 12 Vdc (10 %)
4 - Others, upon request

Communication
0 - None
1 - MODBUS (RS-232)*
2 - MODBUS (RS-485)*
3 - MODBUS (RS-422)*
4 - PROFIBUS DP-V0 (RS-485)**

Case Protection Grade


0 - General usage, protected place
1 - Front aspersion-proof
2 - Weather-proof - IP 66
3 - Explosion-proof (EX d IIB T6 Gb IP 66), horizontal display***

Specifications
Inputs
Thermocouple (J, K, T, E, R, S under ITS-90).
RTD Pt-100 under DIN 43760.
4-20 mA with input impedance of 250 .
1 to 5 Vdc with input impedance >10 M.
Outputs
Up to 2 SPDT relays rated for 3A/220 Vac.
Logic signal, open collector transistor, 24 Vdc/40 mA
maximum with isolation. Solid state relay,
2A/250 Vac with isolation.
Serial Communication
DMY-2015: RS-232 or RS-422/485 with 50 Vdc isolation.
MODBUS-RTU Communication Protocol.
DMY-2015-PB: PROFIBUS DP-V0: RS-485 Communication.
Indication
4-digit red leds display (14 mm) for process variable indication.
2-digit display for channel indication. 12 red leds for alarm
indication.
Totalization
Totalization of eight voltage or current inputs ranging from
0 to 9999, configured with the decimal point.
Configuration
By front-panel push-buttons
Sampling Rate
480 ms standard, for all inputs. One second display update rate.
Accuracy
0.1 % of full scale for TC, RTD, mA, Vdc.
Linearization
0.1 C for RTD and 0.2 C for TC.
Square Root Extraction
0.5 % of reading, for input above 10 % of span.
Programmable Cut-off from 0 to 5 %.
Cold Junction Compensation
2.0 C in ambient temperature range from 0 to 60 C.
Span Temperature Coefficient
0.005 % of span / C using 25 C as the reference temperature.
Power Supply
75 to 264 Vac 50/60 Hz or 100 to 360 Vdc
(10 W nominal); 24 Vac/dc (10 %); 12 Vdc (10 %).
Operating Range
0 to 60 C temperature and 90 % maximum relative humidity.
Dimensions
1/4 DIN (96 x 96 x 187 mm) HxWxD, (92 x 92 mm) HxW panel
cutout.
Weight
0.7 kg nominal.
Warranty
One year.

* Available only for DMY-2015 model


** Available only for DMY-2015-PB model
*** Explosion-proof box:
Dimensions
310 x 310 x 200 mm (HxWxD)
Weight
11 kg approx.

presys

Universal Digital
Indicator Single
DMY-2030-Light

DMY-2030-Light: Universal input for RTD, thermocouples, 0-55 mV, 4-20 mA,
1-5 Vdc and 0-10 Vdc.
4 digit display of high visibility.
Linearization for RTD and TC, square root extraction function.
Power supply of 75-264 Vac, 50/60 Hz or 100 to 360 Vdc; 24 Vac/dc and 12 Vdc,
as ordered.
Fully configurable by front-panel push-buttons. Configuration stored in non-volatile memory.
Many optional modules are available:
- Analog output modules of 4-20 mA, 1-5 Vdc and 0-10 Vdc.
- Up to 2 SPDT relay alarm modules.
- Aspersion-proof front-panel.
- Communication RS-232 or RS-422/485 with computer.
High accuracy.

presys
Order Code

DMY

Model
2030-Light

Output 1
0
1
2
3

None
4-20 mA
1-5 Vdc
0-10 Vdc

Output 2
0
1
2
3

None
SPDT Relay
Open Collector Voltage
Solid State Relay

Output 3
Same code as Output 2

Power Supply
1 - 75 to 264 Vac 50/60 Hz or 100 to 360 Vdc (any
polarity)
2 - 24 Vac or 24 Vdc (10 %)
3 - 12 Vdc (10 %)
4 - Others, upon request

Communication
0
1
2
3

None
RS-232
RS-485
RS-422

Case Protection Grade


0 - General usage, protected place
1 - Front Aspersion-proof
2 - Weather-proof - IP 66
3 - Explosion-proof (Ex d IIB T6 Gb IP 66), horizontal display*
* Explosion-proof box:
Dimensions
310 x 310 x 200 mm (HxWxD)
Weight
11 kg approx.

Specifications
Inputs
Configurable for TC (J, K, T, E, R, S under ITS-90), 0-55 mV,
RTD under DIN 43760, 4-20 mA, 1-5 Vdc and 0-10 Vdc.
Input impedance of 250 for mA, >10 M up to 5 Vdc and
2 M above 5 Vdc.
Outputs
4-20 mA (750 maximum load), 1-5 Vdc or 0-10 Vdc analog
retransmitter. Galvanically isolated module to 300 Vac from power
supply and inputs. Up to 2 SPDT relay modules, rated for 3A/220 Vac.
Logic signal, open collector transistor, 24 Vdc/40 mA maximum with
isolation. Solid state relay, 2A/250 Vac with isolation.
Serial Communication
RS-232 or RS-422/485 with 50 Vdc isolation. MODBUS-RTU
Communication Protocol.
Indication
4 digit red leds display (14 mm).
Configuration
By front-panel push-buttons and internal jumpers.
Sampling Rate
64 ms standard.
Accuracy
0.1 % of full scale for TC, RTD, mA, mV and Vdc inputs.
0.5 % of full scale for analog retransmitter output.
Linearization
0.1 C for RTD and 0.2 C for TC.
Square Root Extration
0.5 % of reading, for inputs above 10 % of span.
Programmable cut-off from 0 to 5 %.
Cold Junction Compensation
2.0 C in ambient temperature range from 0 to 60 C.
2-Wire Transmitter Power Supply
24 Vdc/50 mA maximum, isolated from output, with short-circuit
protection.
Span Temperature Coefficient
0.005 % of span / C using 25 C as the reference temperature
Power supply
75 to 264 Vac 50/60 Hz or 100 to 360 Vdc
(10 W nominal); 24 Vac/dc (10 %); 12 Vdc (10 %).
Operating Ambient
0 to 60 C temperature and 90 % maximum relative humidity.
Dimensions
1/8 DIN (48 x 96 x 187 mm) HxWxD, (45 x 92 mm) HxW
panel cutout.
Weight
0.5 kg nominal.
Warranty
One year.

presys

Frequency
Digital Indicator
Single

DMY-2030-F-Light

Input frequency up to 30 kHz, from 300 mVpp to 30 Vpp.


4 1/2 digit display of high visibility.
Power supply of 75-264 Vac, 50/60 Hz or 100 to 360 Vdc; 24 Vac/dc and 12 Vdc,
as ordered.
Fully configurable by front-panel push-buttons. Configuration stored in non-volatile memory.
Many optional modules are available:
- Analog output modules of 4-20 mA, 1-5 Vdc and 0-10 Vdc.
- Up to 2 digital output modules with SPST relay + 2 with SPDT relay modules.
- Aspersion-proof front-panel.
- Communication RS-232 or RS-422/485 with computer
High accuracy.

presys
Order Code

DMY

Model
2030-F-Light: Frequency
Input.

Output 1
0
1
2
3
4
5
6

None
4-20 mA
1-5 Vdc
0-10 Vdc
SPST Relay
Open Collector Voltage
Solid State Relay

Output 2
0
1
2
3

None
SPST Relay
Open Collector Voltage
Solid State Relay

Output 3
0
1
2
3

None
SPDT Relay
Open Collector Voltage
Solid State Relay

Output 4
Same code as Output 3

Power Supply
1 - 75 to 264 Vac 50/60 Hz or 100 to 360 Vdc (any
polarity)
2 - 24 Vac or 24 Vdc (10 %)
3 - 12 Vdc (10 %)
4 - Others, upon request

Communication
0
1
2
3

None
RS-232
RS-485
RS-422

Specifications
Input
One frequency input to connect signals in the wave shapes sine,
square, triangle, pulse with amplitude between 300 mVpp and
30 Vpp and dry contact input. 70 Vdc maximum voltage.
Input impedance greater than 60 k
(sine wave, 1 kHz).
Outputs
4-20 mA (750 maximum load), 1-5 Vdc or 0-10 Vdc analog
retransmitter. Galvanically isolated module to 300 Vac from power
supply and inputs. Up to 2 SPDT + 2 SPST relay modules, rated
for 3A/220 Vac. Logic signal, open collector transistor, 24 Vdc/40 mA
maximum with isolation. Solid state relay, 2A/250 Vac with isolation.
Serial Communication
RS-232 or RS-422/485 with 50 Vdc isolation.
MODBUS-RTU Communication Protocol.
Indication
4 digit red leds display (14 mm).
Configuration
By front-panel push-buttons and internal jumpers
Sampling Rate
71 ms standard.
Half second display update rate.
Accuracy
1 Display resolution for input.
0.5 % of full scale for analog retransmitter output.
Power Supply for frequency sensors
24 Vdc / 50 mA maximum, isolated from output with
short-circuit protection.
Power Supply
75 to 264 Vac 50/60 Hz or 100 to 360 Vdc
(10 W nominal); 24 Vac/dc (10 %); 12 Vdc (10 %).
Operating Range
0 to 60 C temperature and 90 % maximum relative
humidity.
Dimensions
1/8 DIN (48 x 96 x 187 mm) HxWxD, (45 x 92 mm)
HxW panel cutout.
Weight
0.5 kg nominal.
Warranty
One year.

Case Protection Grade


0 - General usage, protected place
1 - Front Aspersion-proof
2 - Weather-proof - IP 66
3 - Explosion-proof (Ex d IIB T6 Gb IP 66), horizontal display*
* Explosion-proof box:
Dimensions
310 x 310 x 200 mm (HxWxD)
Weight
11 kg approx.

presys

Universal
Process
Indicator
Dual
DMY-2030 / DMY-2030-F

DMY-2030 / 2011 / 2035 / 2036:

Two universal inputs for RTD, TC, mV, 4-20 mA,


1-5 Vdc and 0-10 Vdc.

DMY-2030F / 2011F / 2035F / 2036F:

Two frequency inputs up to 30 kHz, from 300 mVpp


to 30 Vpp.

High visibility displays.


Linearization for RTD and thermocouple. Square
root extraction.

Configuration stored in non-volatile memory.

Many optional modules are available:


- Up to 2 analog output modules 4-20 mA,
1-5 Vdc, 0-10 Vdc.
- Up to 2 SPST relay modules + up to 2
SPDT relay modules.
- Aspersion-proof front-panel.
- Communication RS-232 or RS-422/485
with computer

Simultaneous display of channels on models


with two displays.

DMY-2035 /
DMY-2035-F
DMY-2011 /
DMY-2011-F

DMY-2036 / DMY-2036-F

presys
Order Code

DMY

Model

2030 - Universal Inputs


2011 - Universal Inputs
2035 - Universal Inputs
2036 - Universal Inputs
2030-F - Frequency Inputs
2011-F - Frequency Inputs
2035-F - Frequency Inputs
2036-F - Frequency Inputs

Output 1
0
1
2
3
4
5
6

None
4-20 mA
1-5 Vdc
0-10 Vdc
SPST Relay
Open Collector Voltage
Solid State Relay

Output 2

Same code as Output 1

Output 3
0
1
2
3

None
SPDT Relay
Open Collector Voltage
Solid State Relay

Output 4

Same code as Output 3

Power Supply

1 - 75 to 264 Vac 50/60 Hz or 100 to 360 Vdc (any


polarity)
2 - 24 Vac or 24 Vdc (10 %)
3 - 12 Vdc (10 %)
4 - Others, upon request

Communication
0
1
2
3

None
RS-232
RS-485
RS-422

Case Protection Grade


0 - General usage, protected place
1 - Front Aspersion-proof
2 - Weather-proof - IP 66
3 - Explosion-proof (Ex d IIB T6 Gb IP 66), horizontal display*
4 - Explosion-proof (Ex d IIB T6 Gb IP 66), vertical display*

* Explosion-proof box:
Dimensions

310 x 310 x 200 mm (HxWxD)

Weight

11 kg approx.

Specifications
Inputs
DMY-2030/2011/2035/2036: Two configurable inputs for
thermocouple (J, K, T, E, R, S under ITS-90), 0-55 mV,
RTD Pt-100 under DIN 43760, 4-20 mA,1-5 Vdc and
0-10 Vdc. 4-20 mA with input impedance of 250 .
>10 M up to 5 Vdc and 2 M above 5 Vdc.
DMY-2030-F/2011-F/2035-F/2036-F: Two frequency inputs
for signals up to 30 kHz, from 300 mVpp to 30 Vpp.
Outputs
4-20 mA (750 maximum load), 1-5 Vdc or 0-10 Vdc
analog retransmitter. Up to 2 galvanically isolated modules
to 300 Vac from power supply and inputs. Up to 2 SPDT
relay modules and up to 2 SPST relay modules, rated for
3A/220 Vac. Logic signal, open collector transistor,
24 Vdc/40 mA maximum with isolation. Solid state relay,
2A/250 Vac with isolation.
Note: In the case of using an analog output, one can use
three alarm modules, or when using two analog outputs,
one can use up to two alarm modules.
Serial Communication
RS-232 or RS-422/485 with 50 Vdc isolation.
MODBUS-RTU Communication Protocol.
Indication
DMY-2030/2030-F: 4 digit red leds display (14 mm).
DMY-2011/2011-F: 2 x 4-digit red leds display (14 mm).
DMY-2035/2035-F: 2 x 4-digit red leds display (9 mm).
DMY-2036/2036-F: 2 x 4-digit red leds display (14 mm and
9 mm). Can be configured together with the decimal point.
Configuration
By front-panel push-buttons and internal jumpers
Sampling Rate
120 ms standard. One second display update rate.
Accuracy
0.1 % of full scale for TC, RTD, mA, mV and Vdc.
0.5 % of full scale for analog retransmitter output.
1 Display resolution for frequency input.
Linearization
0.1 C for RTD and 0.2 C for TC.
Square Root Extraction
0.5 % of reading, for input above 10 % of span.
Programmable Cut-off from 0 to 5 %.
Cold Junction Compensation
2.0 C in ambient temperature range from 0 to 60 C.
2-wire Transmitter Power Supply
24 Vdc/50 mA maximum, isolated from output with
short circuit protection.
Span Temperature Coefficient
0.005 % of span / C using 25 C as the reference
temperature.
Power Supply
75 to 264 Vac 50/60 Hz or 100 to 360 Vdc
(10 W nominal); 24 Vac/dc (10 %); 12 Vdc (10 %).
Operating Range
0 to 60 C temperature and 90 % maximum relative
humidity.
Dimensions
DMY-2030/2030-F:1/8 DIN (48 x 96 x 187 mm) HxWxD,
(45 x 92 mm) HxW panel cutout .
DMY-2011/2011-F:1/4 DIN (96 x 96 x 187 mm) HxWxD,
(92 x 92 mm) HxW panel cutout .
DMY-2035/2035-F: 1/8 DIN (96 x 48 x 187 mm) HxWxD,
(92 x 45 mm) HxW panel cutout .
DMY-2036/2036-F: 1/8 DIN (48 x 96 x 187 mm) HxWxD,
(45 x 92 mm) HxW panel cutout .
Weight
0.5 kg nominal (DMY-2030/2030-F/2035/2035-F/2036/2036-F)
0.6 kg nominal (DMY-2011/2011-F).
Warranty
One year.

presys

Process Indicator
and Totalizer Single
DMY-2030-TOT-Light
DMY-2030-TOT-F-Light
DMY-2030-TOT-Light: One universal input.
DMY-2030-TOT-F-Light: One frequency input.
Order Code

DMY

Model

2030-TOT-Light: mV, V, mA
input.
2030-TOT-F-Light: Frequency
input.

Output 1
0
1
2
3
4
5
6

None
4-20 mA
1-5 Vdc
0-10 Vdc
SPST Relay
Open Collector Voltage
Solid State Relay

Output 2
Same code as Output 1

Output 3
0
1
2
3

None
SPDT Relay
Open Collector Voltage
Solid State Relay

Output 4
Same code as Output 3

Power Supply

1 - 75 to 264 Vac 50/60 Hz or 100 to 360 Vdc (any


polarity)
2 - 24 Vac or 24 Vdc (10 %)
3 - 12 Vdc (10 %)
4 - Others, upon request

Communication
0
1
2
3

None
RS-232
RS-485
RS-422

Case Protection Grade


0
1
2
3

General Usage, protected place


Front Aspersion-proof
Weather-proof - IP 66
Explosion-proof (Ex d IIB T6 Gb IP 66), horizontal display*

* Explosion-proof box:
Dimensions: 310 x 310 x 200 mm (HxWxD)
Weight: 11 kg nominal

10

8-digit configurable display.


Digital input for partial totalization reset.
Specifications
Inputs
DMY-2030-TOT-Light: Configurable input for 0-55 mV, 4-20 mA, 1-5 Vdc and
0-10 Vdc. 4-20 mA with input impedance of 250 . >10 M up to 5 Vdc
and 2 M above 5 Vdc.
DMY-2030-TOT-F-Light: frequency input for signals up to 30 kHz, from
300 mVpp to 30 Vpp digital input. 70 V maximum DC voltage. Input impedance
greater than 60 k (sine, 1 kHz).
Outputs
4-20 mA (750 maximum load), 1-5 Vdc or 0-10 Vdc analog retransmitter.
Up to 2 galvanically isolated modules to 300 Vac from power supply and inputs.
Up to 2 SPDT relay modules and up to 2 SPST relay modules, rated for
3A/220 Vac. Logic signal, open collector transistor, 24 Vdc/40 mA maximum
with isolation. Solid state relay, 2A/250 Vac with isolation.
Serial Communication
RS-232 or RS-422/485 with 50 Vdc isolation. MODBUS-RTU
Communication Protocol.
Indication
8-digit red leds display (9 mm) for totalization and 5-digit for indication.
Can be configured together with the decimal point.
Totalization Range
0 to 99999999 configured together with the decimal point.
Configuration
By front-panel push-buttons and internal jumpers.
Sampling Rate
120 ms standard. One second display update rate.
Accuracy
0.1 % of full scale for TC, RTD, mA, mV and Vdc.
0.5 % of full scale for analog retransmitter output.
1 Display resolution for frequency input.
Linearization
14 configurable input points.
Square Root Extraction
0.5 % of reading, for input above 10 % of span.
Programmable Cut-off from 0 to 5 %.
2-wire Transmitter Power Supply
24 Vdc/50 mA maximum, isolated from output with short circuit protection.
Span Temperature Coefficient
0.005 % of span / C using 25 C as the reference temperature.
Power Supply
75 to 264 Vac 50/60 Hz or 100 to 360 Vdc (10 W nominal);
24 Vac/dc (10 %); 12 Vdc (10 %).
Operating Range
0 to 60 C temperature and 90 % maximum relative humidity.
Dimensions
1/8 DIN (48 x 96 x 187 mm) HxWxD, (45 x 92 mm) HxW panel cutout.
Weight
0.5 kg nominal.
Warranty
One year.

presys

Process Indicator
and Totalizer Dual
DMY-2030-TOT
DMY-2030-TOT-F
DMY-2030-TOT: Two inputs for mV, 4-20 mA, 1-5 Vdc and 0-10 Vdc.
DMY-2030-TOT-F: Two frequency inputs up to 30 kHz, from 300 mVpp to 30 Vpp.
8-digit display.
Specifications
Order Code

DMY

Model

2030-TOT: mA, Vdc and mV inputs


2030-TOT-F: Frequency inputs

Output 1
0
1
2
3
4
5
6

None
4-20 mA
1-5 Vdc
0-10 Vdc
SPST Relay
Open Collector Voltage
Solid State Relay

Output 2
Same code as Output 1

Output 3
0
1
2
3

None
SPDT Relay
Open Collector Voltage
Solid State Relay

Output 4
Same code as Output 3

Power Supply
1
2
3
4

75 to 264 Vac 50/60 Hz or 100 to 360 Vdc (any polarity)


24 Vac or 24 Vdc (10%)
12 Vdc (10%)
Others, upon request

Communication
0
1
2
3

None
RS-232
RS-485
RS-422

Case Protection Grade


0
1
2
3

General usage, protected place


Front Aspersion-proof
Weather-proof - IP 66
Explosion-proof (Ex d IIB T6 Gb IP 66), horizontal display*

* Explosion-proof box:
Dimensions

310 x 310 x 200 mm (HxWxD)

Weight

11 kg nominal

Inputs
DMY-2030-TOT: Two configurable inputs 0-55 mV, 4-20 mA,
1-5 Vdc and 0-10 Vdc. 4-20 mA with input impedance of 250 .
>10 M up to 5 Vdc and 2 M above 5 Vdc.
DMY-2030-TOT-F: Two frequency inputs for signals up to 30 kHz,
from 300 mVpp to 30 Vpp.
Outputs
4-20 mA (750 maximum load), 1-5 Vdc or 0-10 Vdc analog
retransmitter. Up to 2 galvanically isolated modules to 300 Vac from
power supply and inputs. Up to 2 SPDT relay modules and up to
2 SPST relay modules, rated for 3A/220 Vac. Logic signal, open
collector transistor, 24 Vdc/40 mA maximum with isolation. Solid
state relay, 2A/250 Vac with isolation.
Serial Communication
RS-232 or RS-422/485 with 50 Vdc isolation. MODBUS-RTU
Communication Protocol.
Indication
8-digit red leds display (9 mm) for totalization and 5-digit for
indication. Can be configured together with the decimal point.
Totalization Range
0 to 99999999 configured together with the decimal point.
Configuration
By front-panel push-buttons and internal jumpers.
Sampling Rate
120 ms standard. One second display update rate.
Accuracy
0.1 % of full scale for TC, RTD, mA, mV and Vdc.
0.5 % of full scale for analog retransmitter output.
1 Display resolution for frequency input.
Square Root Extraction
0.5 % of reading, for input above 10 % of span. Programmable
Cut-off from 0 to 5 %.
2-wire Transmitter Power Supply
24 Vdc/50 mA maximum, isolated from output with short
circuit protection.
Span Temperature Coefficient
0.005 % of span / C using 25 C as the reference temperature.
Power Supply
75 to 264 Vac 50/60 Hz or 100 to 360 Vdc (10 W nominal);
24 Vac/dc (10 %); 12 Vdc (10 %).
Operating Range
0 to 60 C temperature and 90 % maximum relative humidity.
Dimensions
1/8 DIN (48 x 96 x 187 mm) HxWxD, (45 x 92 mm) HxW panel
cutout .
Weight
0.5 kg nominal.
Warranty
One year.

11

presys

Process Counter DUAL


DMY-2030-TOT-FCS
DMY-2031-FCS
Ideal for counting of sacks, barrels, etc. or pulses of any sector.
Up to four digital output modules with SPDT and SPST relays.
RS-232 or RS-422/485 Communication.
DMY-2030 -TOT-FCS: Up to 8-digit configurable display.
DMY-2031-FCS: Two 4-digit displays (14 mm and 9 mm).
Robust construction in order to withstand the harshest conditions of industrial use.
Universal power supply of 75 to 264 Vac, 50/60 Hz or 100 to 360 Vdc; 24 Vac/dc and 12 Vdc,
as ordered.

Aspersion-proof Front-panel (optional).


Configuration stored in non-volatile memory.

12

presys
Order Code

DMY-

Model
2031-FCS: 2 x 4-digit display
2030-TOT-FCS: 1 x 8-digit
display

Output 1
0 - None
1 - SPST Relay
2 - Open Collector Voltage
3 - Solid State Relay

Output 2

Same code as Output 1

Output 3
0 - None
1 - SPDT Relay
2 - Open Collector Voltage
3 - Solid State Relay

Output 4

Same code as Output 3

Power Supply
1 - 75 to 264 Vac 50/60 Hz or 100 to 360 Vdc (any
polarity)
2 - 24 Vac or 24 Vdc (10 %)
3 - 12 Vdc (10 %)
4 -Others upon request

Communication
0 - None
1 - RS-232
2 - RS-485
3 - RS-422

Case Protection Grade


0 - General usage, protected place
1 - Front Aspersion-proof
2 - Weather-proof - IP 66
3 - Explosion-proof (Ex d II B6 Gb IP 66), horizontal display*

Specifications
Inputs
Frequency inputs for signals up to 500 Hz, from 300 mVpp to
30 Vpp. DIN 19234 compliance for intrinsically safe NAMUR
sensors.
Outputs
SPST and SPDT relays rated for 3A/220 Vac.
Plug provided for up to 4 modules. Logic Signal, open collector
transistor, 24 Vdc/40 mA, maximum with isolation. Solid State Relay,
2A/250 Vac with isolation.
Serial Communication
RS-232 or RS-422/485 with 50 Vdc isolation. MODBUS-RTU
Communication Protocol.
Indication
DMY-2031-FCS: Two 4-digit red leds displays (9 and 14 mm).
DMY-2030-TOT-FCS: One 8-digit red leds display (9 mm).
Can be configured together with the decimal point.
Totalization Range
DMY-2031-FCS: 0 to 9999 counts.
DMY-2030-TOT-FCS: 0 to 99999999 counts.
Can be configured together with the decimal point.
Configuration
By front-panel push-buttons and internal jumpers.
2-wire Transmitter Power Supply
24 Vdc/50 mA maximum, isolated from output with
short circuit protection.
Power Supply
75 to 264 Vac 50/60 Hz or 100 to 360 Vdc (10 W nominal);
24 Vac/dc (10 %); 12 Vdc (10 %).
Operating Range
0 to 60 C temperature and 90 % maximum relative humidity.
Dimensions
1/8 DIN (48 x 96 x 187 mm) HxWxD, (45 x 92 mm) HxW
panel cutout.
Weight
0.5 kg nominal.
Warranty
One year.

*Explosion-proof box:
Dimensions
310 x 310 x 200 mm (HxWxD)
Weight
11 kg nominal

13

presys

Universal Process Indicator


(Large Digits)
DMY-2032 and DMY-2032-F
Display of 4 large digits (57 mm) that allows easy viewing up to 20 meters away.
DMY-2032: two universal inputs
DMY-2032-F: two frequency inputs.
Other specifications are identical to the DMY-2030 and DMY-2030-F and same order code, in
model field fill as DMY-2032 or DMY-2032-F.

Has characteristics that are common to Presys Line 2000: DMY-20XX, DCY-20XX and TY-20XX.

14

presys

Digital Indicator
for
Load Cell
DMY-2030-CC
Specially developed for use with load cell.
Input range from -30 mV to 30 mV.
Indication with peak hold, minimum and

10V / 100mA power supply for load cell.


TARE function configurable.

maximum.
Order Code

DMY-2030-CC -

Output 1

0 - None
1 - 4-20 mA
2 - 1-5 Vdc
3 - 0-10 Vdc
4 - SPST Relay
5 - Open Collector Voltage
6 - Solid State Relay

Output 2

0 - None
1 - SPDT Relay
2 - Open Collector Voltage
3 - Solid State Relay

Output 3

Same code as Output 2

Power Supply

1 - 75 to 264 Vac 50/60 Hz or 100 to 360 Vdc (any


polarity)
2 - 24 Vac or 24 Vdc (10 %)
3 - 12 Vdc (10 %)
4 - Others, upon request

Communication
0 - None
1 - RS-232
2 - RS-485
3 - RS-422

Case Protection Grade

0 - General usage, protected place


1 - Front Aspersion-proof
2 - Weather-proof - IP 66
3 - Explosion-proof (Ex d IIB T6 Gb IP 66), horizontal display*
* Explosion-proof box:
Dimensions
310 x 310 x 200 mm (HxWxD)
Weight
11 kg nominal

Specifications
Inputs
One -30 to 30 mV input.
Input impedance >10 M.
Outputs
4-20 mA (750 maximum load), 1-5 Vdc or 0-10 Vdc analog
retransmitter. Galvanically isolated module to 300 Vac from power
supply and inputs, one SPST relay module (replacing the analog output)
and up to 2 SPDT relay modules, rated for 3A/220 Vac. Logic signal,
open collector transistor, 24 Vdc/40 mA maximum with isolation.
Solid state relay, 2A/250 Vac with isolation.
Serial Communication
RS-232 or RS-422/485 with 50 Vdc isolation. MODBUS-RTU
Communication Protocol.
Indication
4 digit red leds display (14 mm).
Can be configured together with the decimal point.
Configuration
By front-panel push-buttons and internal jumpers.
Sampling Rate
64 ms standard.
Accuracy
0.1 % of full scale for inputs.
0.5 % of full scale for analog retransmitter output.
Span Temperature Coefficient
0.005 % of span / C using 25 C as the reference temperature.
Power Supply for load cell
10 Vdc/100 mA.
Power Supply
75 to 264 Vac 50/60 Hz or 100 to 360 Vdc
(10 W nominal); 24 Vac/dc (10 %); 12 Vdc (10 %).
Operating Ambient
0 to 60 C temperature and 90 % maximum relative humidity.
Dimensions
1/8 DIN (48 x 96 x 187 mm) HxWxD, (45 x 92 mm) HxW panel
cutout.
Weight
0.5 kg nominal.
Warranty
One year.

15

presys

Flow Calculator DMY-2030-CV


Three 4-20mA and 1-5Vdc standard inputs for flow, temperature and pressure signals.
Calculation of flow rate with/without temperature and/or pressure correction, with/without squared root extraction.
Totalization of the corrected flow and preset.
Flow signal linearization up to 21 points.
Includes water steam table.

Flow Measurement Solution with Temperature and Pressure


Compensation Integrated with Totalization
The flow measurement using the principle of differential pressure orifice plate is one of the methods most frequently
used involving transport of fluids and gases. The method is very widespread, this is due to the following factors:

Simplicity and low cost of installation;


Easy maintenance for measuring elements;
Low values of measurement uncertainties.
Flow measurement by differential pressure has many potential uses and application, mainly by the use of flow
measurement compensated in pressure and temperature.
The Flow Calculator DMY-2030-CV has extruded aluminum metal case. Provides three inputs which can be used
for connection with standard analog signals from the differential pressure sensors, gauge pressure and temperature, and
is also the standard 24 Vdc power supply for two-wire transmitter. Presents the signs of the three inputs through
5 digits, performing the aggregation of flow corrected with 8-digit count, and have reset by the front panel or through
external dry contact.

16

presys
Order Code

DMY-2030-CV

Model
Output 1
0 - None
1 - 4-20 mA
2 - 1-5 Vdc
3 - 0-10 Vdc
4 - SPST Relay
5 - Open Collector Voltage
6 - Solid State Relay

Output 2
0 - None
1 - SPST Relay
2 - Open Collector Voltage
3 - Solid State Relay

Output 3
0 - None
1 - SPDT Relay
2 - Open Collector Voltage
3 - Solid State Relay

Output 4
Same code as Output 3

Power Supply
1 - 75 to 264 Vac 50/60 Hz or 100 to 360 Vdc (any
polarity)
2 - 24 Vac or 24 Vdc (10 %)
3 - 12 Vdc (10 %)
4 - Others, upon request

Communication
0 - None
1 - RS-232
2 - RS-485
3 - RS-422

Case Protection Grade


0 - General usage, protected place
1 - Front Aspersion-proof
2 - Weather-proof - IP 66
3 - Explosion-proof (Ex d IIB T6 Gb IP 66), horizontal display*

Specifications
Inputs
Three configurable inputs for 4-20 mA, 1-5 Vdc.
250 input impedance for mA and >10 M
for 5 Vdc.
Outputs
4-20 mA (750 maximum load), 1-5 Vdc or 0-10 Vdc analog
retransmitter. Galvanically isolated module to 300 Vac from power
supply and inputs. Up to 2 SPST relay modules and up to 2 SPDT
relay modules, rated for 3A/220 Vac. Logic signal, open collector
transistor, 24 Vdc/40 mA maximum with isolation. Solid state relay,
2A/250 Vac with isolation.
Serial Communication
RS-232 or RS-422/485 with 50 Vdc isolation. MODBUS-RTU
Protocol
Indication
8-digit red leds display (9 mm) for totalization and 5 digits for
indication. Can be configured together with the decimal point.
Totalization
0 to 99999999. Can be configured together with the decimal point.
Configuration
By front-panel push-buttons and internal jumpers.
Sampling Rate
120 ms standard. One second display update.
Accuracy
0.1 % of full scale for mA and Vdc inputs.
0.5 % of full scale for analog retransmitter output.
Square Root Extraction
0.5 % of reading, for input above 10 % of span. Programmable
Cut-off from 0 to 5 %.
2-wire Transmitter Power Supply
24 Vdc/50 mA maximum, isolated from output with short circuit
protection
Span Temperature Coefficient
0.005 % of span / C using 25 C as the reference temperature.
Power Supply
75 to 264 Vac 50/60 Hz or 100 to 360 Vdc
(10 W nominal); 24 Vac/dc (10 %); 12 Vdc (10 %).
Operating Ambient
0 to 60 C temperature and 90 % maximum relative humidity.
Dimensions
1/8 DIN (48 x 96 x 187 mm) HxWxD, (45 x 92 mm) HxW panel
cutout.
Weight
0.5 kg nominal.
Warranty
One year.

*Explosion-proof box:
Dimensions
310 x 310 x 200 mm (HxWxD)
Weight
11 kg nominal

17

presys

Pressure Indicator Single


DMY-2017-Light

An input for pressure, use with gases and liquids.


Range from 250 mmH2O to 5000 psi, gauge pressure, absolute or vacuum.
Other characteristics in common to the line 2000 (DMY-20XX; DCY-20XX; TY-20XX).

Pressure Indicator Dual

DMY-2017

Two inputs for pressure, use with gases and liquids.


Range from 250 mmH2O to 5000 psi, gauge pressure, absolute or vacuum.
Other characteristics in common to the line 2000 (DMY-20XX; DCY-20XX; TY-20XX).
18

presys
Order Code

DMY -

Specifications

Model

2017-Light
2017

Input 1
Range

1 - 0 to 250 mmH2O
2 - 0 to 1 psi
3 - 0 to 5 psi
4 - 0 to 15 psi
5 - 0 to 30 psi
6 - 0 to 100 psi
7 - 0 to 250 psi
8 - 0 to 500 psi
9 - 0 to 1000 psi
10 - 0 to 3000 psi *
11 - 0 to 5000 psi *

Only
non-corrosive
gases

Fluids
compatible
with 316
stainless steel

Pressure Type

1 - Gauge
2 - Absolute
3 - Vacuum (0 to 1 atm)

Sensor Type

1 - For air or non-corrosive


gases
2 - For fluids compatible with 316 stainless
steel

Input 2

Only for the model DMY-2017


Same code as Input 1 when used for pressure.
When not being used for pressure, or if the model is
DMY-2017-Light, fill the blanks with 0-0-0 and it
can be used as analog auxiliary input for Vdc, mA,
RTD, TC.

Output 1

0 - None
1 - 4-20 mA
2 - 1-5 Vdc
3 - 0-10 Vdc
4 - SPST Relay
5 - Open Collector Voltage
6 - Solid State Relay

Output 2

Same code as Output 1 (Only for the model DMY-2017)

Output 3

0 - None
1 - SPDT relay
2 - Open Collector Voltage
3 - Solid State Relay

Output 4

Same code as Output 3

Power Supply

1 - 75 to 264 Vac 50/60 Hz or 100 to 360 Vdc (any polarity)


2 - 24 Vac or 24 Vdc (10 %)
3 - 12 Vdc (10 %)
4 - Others, upon request

Communication

Inputs
DMY-2017-Light: One pressure input.
DMY-2017: One or two pressure inputs.
Input for gauge, absolute pressure or vacuum.
Ranges from 250 mmH2O to 5000 psi (gauge pressure).
Ranges from 15 psi to 1000 psi (Absolute pressure).
Ranges from 1 atm (Vacuum). Use with compressed air
and non-corrosive / conductive gases up to 5 psi.
Air or fluids compatible with 316 stainless steel above 5 psi.
DMY-2017: Auxiliar analog input (for simple version only),
configurable for thermocouple (J, K, T, E, R, S under
ITS-90), 0-55 mV, RTD under DIN 43760, 4-20 mA,
1-5 Vdc and 0-10 Vdc. 250 input impedance for mA,
>10 M up to 5 Vdc and 2 M above 5 Vdc.
Outputs
4-20 mA (750 maximum load), 1-5 Vdc or 0-10 Vdc
analog retransmitter. Up to 2 galvanically isolated modules
to 300 Vac from power supply and inputs. SPDT and SPST
relay modules, rated for 3A/220 Vac. Logic signal, open
collector transistor, 24 Vdc/40 mA maximum with isolation.
Solid state relay, 2A/250 Vac with isolation.
Note: Slot provided for up to 4 alarm modules
(taking the two slots of the analog outputs).
Serial Communication
RS-232 or RS-422/485 with 50 Vdc isolation.
MODBUS-RTU Communication Protocol.
Indication
4-digit red leds display (14 mm). Can be configured
together with the decimal point.
Engineering Units
psi, atm, inH2O, kgf/cm2, mH2O, mmH2O, inHg, mmHg,
cmHg, bar, mbar and kPa.
Configuration
By front-panel push-buttons and internal jumpers.
Sampling Rate
120 ms standard. One second display update rate.
Accuracy
1 % of full scale for 250 mmH2O range.
0.1 % of full scale for the other ranges.
0.1 % of full scale for TC, RTD, mA, mV and Vdc inputs.
0.5 % of full scale for analog retransmitter output.
750 maximum load.
2-wire Transmitter Power Supply
24 Vdc/50 mA maximum, isolated from output with
short circuit protection
Span Temperature Coefficient
0.01 % of span / C for pressure inputs.
0.005 % of span / C for auxiliar analog inputs.
Reference 25 C.
Power Supply
75 to 264 Vac 50/60 Hz or 100 to 360 Vdc
(10 W nominal); 24 Vac/dc (10 %); 12 Vdc (10 %).
Operating Range
0 to 60 C temperature and 90 % maximum relative
humidity.
Dimensions
1/4 DIN (96 x 96 x 187 mm) HxWxD, (92 x 92 mm) HxW
panel cutout.
Pneumatic / hydraulic connection
1/4" Union for plastic tubing for use with air or
1/4" Female NPT for use with other fluids.
Weight
1.0 kg nominal.
Warranty
One year.

0 - None
1 - RS-232
2 - RS-485
3 - RS-422

Case Protection Grade

0 - General usage, protected place


1 - Front Aspersion-proof
2 - Weather-proof - IP 66
* Provided only with remote display.
19

presys

DCY-2060-Light /
DCY-2060-F-Light

DCY-2050-Light /
DCY-2050-F-Light

DCY-2051-Light /
DCY-2051-F-Light

Universal Process Controllers - Single Loop


Universal standard input for RTD, thermocouples, 0-55 mV, 4-20 mA,
1-5 Vdc and 0-10 Vdc and remote setpoint input for 4-20 mA, 1-5 Vdc and 0-10 Vdc.

F-Light version for frequency inputs up to 30 kHz, from 300 mVpp to 30 Vpp.
Up to 2 universal output modules for 4-20 mA, 1-5 Vdc and 0-10 Vdc, one for control and
one for retransmission, relay, solid state relay and open collector voltage, isolated from inputs
and power supply.

High control capacity, performing the functions of:


- Auto-Tune.
- ON-OFF, P-PI-PD-PID, ratio control.
- Heating-cooling, time-proportional.
- Remote setpoint, programmable setpoint up to ten segments.
- Auto/manual station.

Several optional:
- Up to 2 SPDT + 2 SPST relay alarm modules;
- RS-232 or RS-422/485 Communication;

Linearization for RTD and TC and also square root extraction.


Configuration stored in non-volatile memory.

20

presys
Order Code

DCY -

Model

2050-Light: Universal Input


2051-Light: Universal Input
2060-Light: Universal Input
2050-F-Light: Frequency Input
2051-F-Light: Frequency Input
2060-F-Light: Frequency Input

Output 1 (Only for Control)


0 - None
1 - 4-20 mA
2 - 1-5 Vdc
3 - 0-10 Vdc
4 - SPST Relay
5 - Open Collector Voltage
6 - Solid State Relay

Output 2

(Retransmitter or auxiliar cooling control)


Same code as Output 1

Output 3 (Alarm)

0 - None
1 - SPDT Relay
2 - Open Collector Voltage
3 - Solid State Relay

Output 4 (Alarm)

Same code as Output 3

Power Supply

1 - 75 to 264 Vac 50/60 Hz or 100 to 360 Vdc (any


polarity)
2 - 24 Vac or 24 Vdc (10 %)
3 - 12 Vdc (10 %)
4 - Others, upon request

Communication
0 - None
1 - RS-232
2 - RS-485
3 - RS-422

Case Protection Grade

0 - General usage, protected place


1 - Front Aspersion-proof
2 - Weather-proof - IP 66
3 - Explosion-proof (Ex d IIB T6 Gb IP 66), horizontal display*
4 - Explosion-proof (EX d IIB T6 Gb IP 66), vertical display*
* Explosion-proof box:
Dimensions

310 x 310 x 200 mm (HxWxD)

Weight

11 kg nominal

Specifications
Inputs
DCY-2050-Light / 2051-Light / 2060-Light: Configurable input for
thermocouple (J, K, T, E, R, S under ITS-90), 0-55 mV, RTD Pt-100
under DIN43760, 4-20 mA, 1-5 Vdc and 0-10 Vdc. Input for remote
setpoint configurable for 4-20 mA, 1-5 Vdc and 0-10 Vdc. 250 input
impedance for mA, >10 M up to 5 Vdc and 2 M above 5 Vdc.
DCY-2050-F-Light / 2051-F-Light / 2060-F-Light: Frequency input for
signals up to 30 kHz, from 300 mVpp to 30 Vpp. DIN-19234 compliance
for intrinsecally safe NAMUR sensors.
Control Function
ON-OFF, PID, PID with AUTO-TUNE, Heating-cooling, Heating-cooling
proportional, Ratio, Remote Set point and programmable set
point.
Control Outputs
Analog 4-20 mA (750 maximum load), 1-5 Vdc or 0-10 Vdc.
One optional module galvanically isolated to 300 Vac from power supply
and inputs. SPST relay rated for 3A/220 Vac. Open collector transistor
(24 Vdc/40 mA maximum with isolation). Solid state relay (2A/250 Vac
with isolation).
Alarm Outputs
SPDT relay rated for 3A/220 Vac. Open collector transistor
(24 Vdc/40 mA maximum with isolation). Solid state relay (2A/250 Vac
with isolation).
Serial Communication
RS-232 or RS-422/485 with 50 Vdc isolation. MODBUS-RTU
Communication Protocol.
Indication
DCY-2050-Light / 2050-F-Light: Two 4-digit displays (9 mm).
DCY-2051-Light / 2051-F-Light: Two 4-digit displays (14 mm / 9 mm).
DCY-2060-Light / 2060-F-Light: Two 4-digit displays (14 mm).
Can be configured together with the decimal point.
Configuration
By front-panel push-buttons and internal jumpers.
Sampling Rate
130 ms standard. Half second display update rate.
Accuracy
0.1 % of full scale for TC, RTD, mA, mV and Vdc inputs.
0.5 % of full scale for analog retransmitter output.
1 display resolution for frequency input.
Linearization
0.1 C for RTD and 0.2 C for TC.
Square Root Extraction
0.5 % of reading, for inputs above 10 % of span.
Programmable Cut-off from 0 to 5 %.
Cold Junction Compensation
2.0 C at range from 0-60 C ambient temperature.
2-wire transmitter Power Supply
24 Vdc/50 mA maximum, isolated from output, with short circuit
protection.
Span Temperature Coefficient
0.005 % of span / C using 25 C as the reference temperature.
Power Supply
75 to 264 Vac 50/60 Hz or 100 to 360 Vdc
(10 W nominal); 24 Vac/dc (10 %); 12 Vdc (10 %).
Operating Range
0 to 60 C temperature and 90 % maximum relative humidity.
Dimensions
DCY-2050-Light/2050-F-Light: 1/8 DIN (96 x 48 x 187 mm) HxWxD,
(92 x 45 mm) HxW panel cutout.
DCY-2051-Light/2051-F-Light: 1/8 DIN (48 x 96 x 187 mm) HxWxD,
(45 x 92 mm) HxW panel cutout.
DCY-2060-Light/2060-F-Light: 1/4 DIN (96 x 96 x 187 mm) HxWxD,
(92 x 92 mm) HxW panel cutout.
Weight
0.5 kg nominal (DCY-2050-Light/2050-F-Light/2051-Light/2051-F-Light).
0.6 kg nominal (DCY-2060 Light/2060-F-Light).
Warranty
One year.

21

presys

DCY-2051 / DCY-2051-F

DCY-2060 / DCY-2060-F
DCY-2050 / DCY-2050-F

Universal Process Controllers - Dual Loop


Two standard universal inputs for RTD, thermocouples, 0-55 mV, 4-20 mA,1-5 Vdc and 0-10 Vdc.
F versions for frequency inputs up to 30 kHz, from 300 mVpp to 30 Vpp.
Up to 2 universal output modules for 4-20 mA, 1-5 Vdc and 0-10 Vdc, one for control and
one for retransmission, relay, solid state relay and open collector voltage isolated from inputs
and power supply.
Reduced dimensions and high control capacity, performing the functions of:
- Auto-Tune.
- ON-OFF, P-PI-PD-PID, ratio, cascade control.
- Heating-cooling, time-proportional.
- Remote setpoint, programmable setpoint up to ten segments.
- Auto/manual station.
Several optional:
- Up to 3 SPDT and SPST relay alarm modules;
- RS-232 or RS-422/485 Communication;
Linearization for RTD and TC and also square root extraction.
Configuration stored in non-volatile memory.
Also available in the model DCY-2055, without local indication, configurable via serial communication
or through portable programmer.
22

presys
Order Code

Specifications
DCY -

Model

2050: Universal Inputs


2051: Universal Inputs
2060: Universal Inputs
2055: Universal Inputs (without
local indication)
2050-F: Frequency Inputs
2051-F: Frequency Inputs
2060-F: Frequency Inputs

Output 1 (Only for Control)


0 - None
1 - 4-20 mA
2 - 1-5 Vdc
3 - 0-10 Vdc
4 - SPST Relay
5 - Open Collector Voltage
6 - Solid State Relay

Output 2 (Control or Alarm)


Same code as Output 1

Output 3 (Alarm or aux. cooling control 1)


0 - None
1 - SPDT Relay
2 - Open Collector Voltage
3 - Solid State Relay

Output 4 (Alarm or aux. cooling control 2)


Same code as output 3

Power Supply
1 - 75 to 264 Vac 50/60 Hz or 100 to 360 Vdc (any polarity)
2 - 24 Vac or 24 Vdc (10 %)
3 - 12 Vdc (10 %)
4 - Others, upon request

Communication
0 - None
1 - RS-232
2 - RS-485
3 - RS-422

Case Protection Grade


0 - General usage, protected place
1 - Front Aspersion-proof
2 - Weather-proof - IP 66
3 - Explosion-proof (Ex d IIB T6 Gb IP 66), horizontal display*
4 - Explosion-proof (EX d IIB T6 Gb IP 66), vertical display*
* Explosion-proof box:
Dimensions

310 x 310 x 200 mm (HxWxD)

Weight

11 kg nominal

Entradas
DCY-2050 / 2051 / 2060 / 2055: Configurable inputs for
thermocouple (J, K, T, E, R, S under ITS-90), 0-55 mV,
RTD Pt-100 under DIN43760, 4-20 mA, 1-5 Vdc and
0-10 Vdc. Input for remote setpoint configurable for
4-20 mA, 1-5 Vdc and 0-10 Vdc. 250 input impedance
for mA, >10 M up to 5 Vdc and 2 M above 5 Vdc.
DCY-2050-F / 2051-F / 2060-F:
Frequency inputs for signals up to 30 kHz, from 300 mVpp
to 30 Vpp. DIN-19234 compliance for intrinsecally safe
NAMUR sensors.
Control Functions
ON-OFF, PID, PID with AUTO-TUNE, Heating-cooling,
Ratio, Cascade, Remote Set point and programmable set point.
Control Outputs
Analog 4-20 mA (750 maximum load), 1-5 Vdc or 0-10 Vdc.
Up to two optional module galvanically isolated to 300 Vac from
power supply and inputs. SPST relay rated for 3A/220 Vac. Open
collector transistor (24 Vdc/40 mA maximum with isolation).
Solid state relay (2A/250 Vac with isolation).
Alarm Outputs
SPDT relay rated for 3A/220 Vac. Open collector transistor
(24 Vdc/40 mA maximum with isolation). Solid state relay
(2A/250 Vac with isolation).
Serial Communication
RS-232 or RS-422/485 with 50 Vdc isolation. MODBUS-RTU
Communication Protocol.
Indication
DCY-2050 / 2050-F: Two 4-digit displays (9 mm).
DCY-2051 / 2051-F: Two 4-digit displays (14 mm / 9 mm).
DCY-2060 / 2060-F: Two 4-digit displays (14 mm).
DCY-2055: Without local indication.
Can be configured together with the decimal point.
Configuration
DCY-2050 / DCY-2051 / DCY-2060: By front-panel push-buttons
and internal jumpers. DCY-2055: Via serial communication or
MCY-25 configuration module.
Sampling Rate
130 ms standard. Half second display update rate.
Accuracy
0.1 % of full scale for TC, RTD, mA, mV and Vdc inputs.
0.5 % of full scale for analog retransmitter output.
1 display resolution for frequency input.
Linearization
0.1 C for RTD and 0.2 C for TC.
Square Root Extraction
0.5 % of reading, for inputs above 10 % of span.
Programmable Cut-off from 0 to 5 %.
Cold Junction Compensation
2.0 C at range from 0-60 C ambient temperature.
2-wire transmitter Power Supply
24 Vdc/50 mA maximum, isolated from output, with short circuit
protection.
Span Temperature Coefficient
0.005 % of span / C for auxiliar input .Reference temperature: 25 C.
Power Supply
75 to 264 Vac 50/60 Hz or 100 to 360 Vdc
(10 W nominal); 24 Vac/dc (10 %); 12 Vdc (10 %).
Operating Range
0 to 60 C temperature and 90 % maximum relative humidity.
Dimensions
DCY-2050 / 2050-F: 1/8 DIN (96 x 48 x 187 mm) HxWxD,
(92 x 45 mm) HxW panel cutout.
DCY-2051 / 2051-F: 1/8 DIN (48 x 96 x 187 mm) HxWxD,
(45 x 92 mm) HxW panel cutout.
DCY-2060 / 2060-F: 1/4 DIN (96 x 96 x 187 mm) HxWxD,
(92 x 92 mm) HxW panel cutout.
DCY-2055: (140 x 53 x 175 mm) HxWxD.
Weight
0.5 kg nominal (DCY-2050/2051)
0.6 kg nominal (DCY-2060/2055)
Warranty
One year.

23

presys

3 Elements
Digital Controller
for Boiler Level
DCY-2050-LC / DCY-2051-LC
DCY-2060-LC
3 Elements control: boiler level, water flow and
steam flow.
Three standard inputs for 4-20 mA and 1-5 Vdc,
configurable.
Order Code

DCY -

-LC -

Model

2050: 1/8 DIN case, vertical display


2051: 1/8 DIN case horizontal display
2060: 1/4 DIN case.

Output 1 (2 elements control)


0 - None
1 - 4-20 mA
2 - 1-5 Vdc
3 - 0-10 Vdc

Output 2 (3 elements control)


Same code as Output 1

Output 3 (Alarm)
0 - None
1 - SPDT Relay
2 - Open Collector
3 - Solid State Relay

Output 4 (Alarm)

Same code as Output 3

Power Supply

1 - 75 to 264 Vac 50/60 Hz or 100 to 360 Vdc (any polarity)


2 - 24 Vac or 24 Vdc (10 %)
3 - 12 Vdc (10 %)
4 - Others, upon request

Communication
0 - None
1 - RS-232
2 - RS-485
3 - RS-422

Case Protection Grade

0 - General usage, protected place


1 - Front Aspersion-proof
2 - Weather-proof - IP 66
3 - Explosion-proof (Ex d IIB T6 Gb IP 66), horizontal display*
4 - Explosion-proof (EX d IIB T6 Gb IP 66), vertical display*
* Explosion-proof box:
Dimensions
310 x 310 x 200 mm (HxWxD)
Weight
11 kg nominal

24

Two analog outputs for 4-20 mA, 1-5 Vdc


and 0-10 Vdc, one for control 3 elements
control and one for 2 elements control.
Specifications
Inputs
Configurable for 4-20 mA and 1-5 Vdc. 250 input impedance for mA
and >10 M for 5 Vdc.
Functions
P-PI-PD-PID Control. Flow totalization. Auto/Manual Station.
Control Outputs
Analog 4-20 mA (750 maximum load), 1-5 Vdc or 0-10 Vdc, configurable.
Alarm Outputs
Up to 2 SPDT rated for 3A/220 Vac.
Open collector transistor (24 Vdc/40 mA maximum with isolation). Solid state
relay (2A/250 Vac with isolation).
Serial Communication
RS-232 or RS-422/485 with 50 Vdc isolation. MODBUS-RTU
Communication Protocol.
Indication
DCY-2050-LC: Two 4-digit displays (9 mm).
DCY-2051-LC: Two 4-digit displays (14 mm/9 mm).
DCY-2060-LC: Two 4-digit displays (14 mm).
Can be configured together with the decimal point.
Configuration
By front-panel push-buttons and internal jumpers.
Sampling Rate
120 ms standard. Half second display update rate.
Accuracy
0.1 % of full scale for mA and Vdc inputs.
0.5 % of full scale for analog output.
Square Root Extraction
0.5 % of reading, for inputs above 10 % of span. Programmable Cut-off from
0 to 5 %.
2-wire Transmitter Power Supply
24 Vdc/50 mA maximum, isolated from output, with short circuit protection.
Span Temperature Coefficient
0.005 % of span / C for auxiliar input. Reference temperature: 25 C.
Power Supply
75 to 264 Vac 50/60 Hz or 100 to 360 Vdc (10 W nominal);
24 Vac/dc (10 %); 12 Vdc (10 %).
Operating Range
0 to 60 C temperature and 90 % maximum relative humidity.
Dimensions
DCY-2050-LC: 1/8 DIN (96 x 48 x 187 mm) HxWxD, (92 x 45 mm) HxW panel cutout.
DCY-2051-LC: 1/8 DIN (48 x 96 x 187 mm) HxWxD, (45 x 92 mm) HxW panel cutout.
DCY-2060-LC: 1/4 DIN (96 x 96 x 187 mm) HxWxD, (92 x 92 mm) HxW panel cutout.
Weight
0.5 kg nominal (DCY-2050-LC/2051-LC) / 0.6 kg nominal (DCY-2060-LC).
Warranty
One year.

presys

Auto/Manual
Station
DCY-2058 /
DCY-2059
Two standard inputs for 4-20 mA, 1-5 Vdc and

Configurable as Auto-Manual Station, Manual

0-10 Vdc.
Up to 2 analog outputs for 4-20 mA, 1-5 Vdc
and 0-10 Vdc, galvanically isolated from inputs
and power supply.
Configuration stored in non-volatile memory.

Station or Automatic Station.


11 linearization points of the output signal.
RS-232 or RS-422/485 Communication.
Universal Power Supply: 75 to 264 Vac,
50/60 Hz, 24 Vac/dc or 12 Vdc, as ordered.

Order Code

DCY-

Model

2058: 1/8 DIN case, vertical display


2059: 1/8 DIN case, horizontal display

Version

1 - Single Loop
2 - Dual Loop

Power Supply

1 - 75 to 264 Vac 50/60 Hz or 100 to 360 Vdc


(any polarity)
2 - 24 Vac or 24 Vdc (10 %)
3 - 12 Vdc (10 %)
4 - Others, upon request

Communication
0 - None
1 - RS-232
2 - RS-485
3 - RS-422

Case Protection Grade

0 - General usage, protected place


1 - Front Aspersion-proof
2 - Weather-proof - IP 66
3 - Explosion-proof (Ex d IIB T6 Gb IP 66), horizontal display*
4 - Explosion-proof (Ex d IIB T6 Gb IP 66), vertical display*
* Explosion-proof box:
Dimensions
310 x 310 x 200 mm (HxWxD)
Weight
11 kg nominal

Specifications
Inputs
Two configurable inputs for 4-20 mA, 1-5 Vdc and 0-10 Vdc, selected by the user.
250 input impedance for mA, >10 M for 5 Vdc and 2 M above 5 Vdc.
Outputs
Analog 4-20 mA (750 maximum load), 1-5 Vdc or 0-10 Vdc. Up to 2 optional
modules galvanically isolated to 300 Vac from power supply and inputs
Serial Communication
RS-232 or RS-422/485 with 50 Vdc isolation. MODBUS-RTU
Communication Protocol.
Indication
DCY-2058: Two 4-digit red leds display (9 mm).
DCY-2059: Two 4-digit red leds display (9 mm and 14 mm).
Can be configured together with the decimal point.
Configuration
By front-panel push-buttons and internal jumpers.
Sampling Rate
Simple Station: 64 ms standard. Half second display update rate.
Dual Station: 120 ms standard. 0.6 seconds display update rate.
Accuracy
0.5 % of full scale for input indication and output generation.
2-wire transmitter Power Supply
24 Vdc/50 mA maximum, isolated from output, with short circuit protection.
Power Supply
75 to 264 Vac 50/60 Hz or 100 to 360 Vdc
(10 W nominal); 24 Vac/dc (10 %); 12 Vdc (10 %).
Operating Range
0 to 60 C temperature and 90 % maximum relative humidity.
Dimensions
DCY-2058: 1/8 DIN (96 x 48 x 187 mm) HxWxD,
(92 x 45 mm) HxW panel cutout.
DCY-2059: 1/8 DIN (48 x 96 x 187 mm) HxWxD,
(45 x 92 mm) HxW panel cutout.
Weight
0.5 kg nominal.
Warranty
One year.

25

presys

Pressure Controller DCY-2057


Direct input for pressure, gases and liquids.

Ranges: 0 to 250 mmH2O, 1 psi, 5 psi, 15 psi, 30 psi, 100 psi, 250 psi, 500 psi and 1000 psi.
Gauge or absolute pressure and vacuum.

Auxiliar universal input for RTD, thermocouple, 0-55 mV, 4-20 mA, 1-5 Vdc and 0-10 Vdc.
Mounting options in weather-proof box.
High control capacity, performing the functions of:

- Auto-tune.
- ON-OFF, P-PI-PD-PID, ratio, cascade control.
- Remote Setpoint, programmable set point up to 10 segments
- Auto/manual station.

Several options available:

- Up to 2 analog output modules 4-20 mA, 1-5 Vdc and 0-10 Vdc.
- Up to 3 alarm modules with SPDT and SPST relays.
- Front Aspersion-proof.
- RS-232 or RS-422/485 Communication.

Ideal for
Pressure and
Temperature
Control
in
Reactors

Robust construction in order to support the harshest conditions of industrial use.

75 to 264 Vac, 50/60 Hz or 100 to 360 Vdc; 24 Vac/dc and 12 Vdc power supply,
as ordered.

High level of accuracy, also performs square root extraction.


Fully programmable from the front panel. Configuration stored in non-volatile memory.
26

presys
Order Code

DCY-2057 -

Input
Range

1 - 0 to 250 mmH2O
*
2 - 0 to 1 psi
3 - 0 to 5 psi
4 - 0 to 15 psi
5 - 0 to 30 psi
6 - 0 to 100 psi
**
7 - 0 to 250 psi
8 - 0 to 500 psi
9 - 0 to 1000 psi

Pressure Type

1 - Gauge
2 - Absolute
3 - Vacuum (0 to 1 atm)

Sensor Type

1 - For air or non-corrosive gases


2 - For fluids compatible with
316 Stainless Steel (sealed)
* air or non-corrosive gases
** sealed

Output 1 (Control)

0 - None
1 - 4-20 mA
2 - 1-5 Vdc
3 - 0-10 Vdc
4 - SPST Relay
5 - Open Collector Voltage
6 - External Solid State Relay

Output 2 (Alarm)

Same code as Output 1

Output 3 (Alarm)

0 - None
1 - SPDT Relay
2 - Open Collector Voltage
3 - Solid State Relay

Output 4 (Alarm)

Same code as Output 3

Power Supply

1 - 75 to 264 Vac 50/60 Hz or 100 to 360 Vdc (any


polarity)
2 - 24 Vac or 24 Vdc (10 %)
3 - 12 Vdc (10 %)
4 - Others, upon request

Specifications
Inputs
Input for vacuum, gauge or absolute pressure.
Ranges from 250 mmH2O to 1000 psi (Gauge Pressure).
Ranges from 15 psi to 1000 psi (Absolute Pressure). Range up to
1 atm (Vacuum). Use with compressed air and non-corrosive /
condutive gases, up to 5 psi. Above 5 psi, use with liquids and
fluids compatible with 316 stainless steel. Auxiliar analog input for TC
(J, K, T, E, R, S under ITS-90), 0-55 mV, RTD Pt-100, under
DIN-43760, 4-20 mA, 1-5 Vdc and 0-10 Vdc. 250 input impedance
for mA, >10 M up to 5 Vdc and 2 M above 5 Vdc.
Control Functions
ON-OFF, PID, PID with AUTO-TUNE, Ratio, Cascade and Remote
Set point.
Control Output
Analog 4-20 mA (750 maximum load), 1-5 Vdc or 0-10 Vdc.
Up to 2 optional module galvanically isolated to 300 Vac from power
supply and inputs. SPST Relay rated for 3A/220 Vca. Open collector
transistor (24 Vdc/40 mA maximum with isolation). Solid state relay
(2A/250 Vac maximum with isolation).
Alarm Outputs
SPDT relay rated for 3A/220 Vac. Open Collector Transistor (24 Vdc/40 mA
maximum with isolation). Solid state relay (2A/250 Vac with isolation).
Serial Communication
RS-232 or RS-422/485 with 50 Vdc isolation. MODBUS-RTU
Communication Protocol.
Indication
Two 4-digit red leds displays (14 mm) which can be configured together
with the decimal point.
Configuration
By front-panel push-buttons and internal jumpers.
Sampling Rate
130 ms standard. Half second display update rate.
Accuracy
1 % of full scale for the range of 250 mmH2O.
0.1 % of full scale for the other pressure ranges.
0.1 % of full scale for TC, RTD, mA, mV and Vdc inputs.
0.5 % of full scale for analog retransmitter output, 750 maximum load .
Linearization
0.1 C for RTD and 0.2 C for TC.
Square Root Extraction
0.5 % of reading, for inputs above 10 % of span.
Programmable Cut-off from 0 to 5 %.
Cold Junction Compensation
2.0 C at range from 0-60 C ambient temperature.
2-wire transmitter Power Supply
24 Vdc/50 mA maximum, isolated from output, with short circuit
protection.
Span Temperature Coefficient
0.005 % of span / C for auxiliar analog input.
0.01 % of span / C for pressure inputs.
Reference temperature: 25 C
Power Supply
75 to 264 Vac 50/60 Hz or 100 to 360 Vdc
(10 W nominal); 24 Vac/dc (10 %); 12 Vdc (10 %).
Operating Range
0 to 60 C temperature and 90 % maximum relative humidity.
Dimensions
1/4 DIN (96 x 96 x 187 mm) HxWxD, (92 x 92 mm) HxW panel cutout.
Weight
1.0 kg nominal.
Warranty
One year.

Communication
0 - None
1 - RS-232
2 - RS-485
3 - RS-422

Case Protection Grade

0 - General usage, protected place


1 - Front Aspersion-proof
2 - Weather-proof - IP 66

27

presys

Universal
Smart
Transmitter
TY-2090 /
TY-2090-F

Transmitter and / or Alarm Monitor in one instrument, it may have up to four alarm modules.
TY-2090: Two universal standard inputs for RTD, TC, 0-55 mVdc, 4-20 mA, 1-5 Vdc and 0-10 Vdc.
TY-2090-F: Two frequency inputs, up to 30 kHz, from 300 mVpp to 30 Vpp.
One or two universal output for 4-20 mA, 1-5 Vdc, 0-10 Vdc, isolated from inputs.
Programmable via serial communication or through portable configurator.
Linearization for RTD and TC. Square root extraction.
Configuration stored in non-volatile memory.
DIN rail or surface assembly.
RS-232 or RS-422/485 Communication (optional).

28

presys
Order Code

TY -

Model
2090: Universal Inputs
2090-F: Frequency Inputs

Output 1
0 - None
1 - 4-20 mA
2 - 1-5 Vdc
3 - 0-10 Vdc
4 - SPST Relay
5 - Open Collector Voltage
6 - Solid State Relay

Output 2

Same code as Output 1

Output 3
0 - None
1 - SPDT Relay
2 - Open Collector Voltage
3 - Solid State Relay

Output 4

Same code as Output 3

Power Supply
1 - 75 to 264 Vac 50/60 Hz or 100 to 360 Vdc (any
polarity)
2 - 24 Vac or 24 Vdc (10 %)
3 - 12 Vdc (10 %)
4 - Other, upon request

Communication
0 - None
1 - RS-232
2 - RS-485
3 - RS-422

Case Protection Grade


0 - General usage, protected place, surface assembly
1 - General usage, protected place, DIN rail assembly
2 - Weather-proof - IP 66
3 - Explosion-proof (Ex d IIB T6 Gb IP 66), without display*
4 - Dust-proof

Specifications
Inputs
TY-2090: Configurable inputs for thermocouple (J, K, T, E,
R, S under ITS-90), 0-55 mV, RTD Pt-100 under DIN 43760,
4-20 mA, 1-5 Vdc and 0-10 Vdc. 250 input impedance for mA,
>10 M up to 5 Vdc and 2 M above 5 Vdc.
TY-2090-F: Frequency inputs for signals up to 30 kHz, from
300 mVpp to 30 Vpp. DIN-19234 compliance for intrinsically safe
NAMUR sensors.
Outputs
4-20 mA (750 maximum load), 1-5 Vdc or 0-10 Vdc analog
retransmitter. Up to 2 galvanically isolated module to 300 Vac
from power supply and inputs. Up to 2 SPST relay modules and
up to 2 SPDT relay modules, rated for 3A/220 Vac. Logic signal,
open collector transistor, 24 Vdc/40 mA maximum with isolation.
Solid state relay, 2A/250 Vac with isolation.
Serial Communication
RS-232 or RS-422/485 with 50 Vdc isolation. MODBUS-RTU
Communication Protocol.
Configuration
Via serial communication or MCY-20 configuration module.
Sampling Rate
120 ms standard.
Accuracy
0.1 % of full scale for TC, RTD, mA, mV and Vdc inputs, with
acquisition via RS-232 or RS-422/485 communication.
0.2 % of full scale for analog output and maximum load of 750.
1 display resolution for frequency input.
Linearization
0.1 C for RTD and 0.2 C for TC.
Square Root Extraction
0.5 % of reading, for inputs above 10 % of span.
Programmable Cut-off from 0 to 5 %.
Cold Junction Compensation
2.0 C at range from 0-60 C ambient temperature.
2-wire transmitter Power Supply
RS-232 or RS-422/485 with 50 Vdc isolation. MODBUS-RTU
Communication Protocol.
Span Temperature Coefficient
0.005 % of span / C using 25 C as the reference temperature
for acquisition by RS-232 or RS-422/485.
0.015 % of span / C using 25 C as the reference temperature
for analog output.
Power Supply
75 to 264 Vac 50/60 Hz or 100 to 360 Vdc (any polarity)
(10 W nominal); 24 Vac/dc (10 %); 12 Vdc (10 %).
Operating Range
0 to 60 C temperature and 90 % maximum relative humidity.
Dimensions
(140 x 53 x 175 mm) HxWxD.
Weight
0.5 kg nominal.
Warranty
One year.

* Explosion-proof box:
Dimensions
310 x 310 x 200 mm (HxWxD)
Weight
11 kg nominal

29

presys

Pressure to
Current
Converter (P/I)
TY-1110-DIN
Converts pressure signal normally 3 to 15 psi for
signal 4 to 20 mA, two-wire system using
semiconductor device (solid state).

Has no moving parts, does not require the usual


periodic maintenance on pneumatic tools using
nozzle-baffle systems, holes, diaphragms etc.

Order Code:
TY-1110-DIN
Model
Input
3/15 - 3 to 15 psig.
Other values, upon request.
Note: Values within the maximum and minimum
limits of span, for absolute pressure or gauge.

Output
4/20 - 4 to 20 mAdc.

Power Supply
24 - 24 Vdc (2-wire system).

Connection
01 - Union for " flexible hose.

Code Example
TY-1110-DIN 3/15 4/20 24 01.
Defines a converter TY-1110-DIN pressure to current of input
3-15 psig and output 4-20 mAdc with 24Vdc power supply
and pneumatic connections type union for " flexible hose.

30

Specifications
Ranges
0 to 250 mmH2O minimum.
0 to 100 psig / psia maximum.
Pressure Type
Gauge or Absolute.
Accuracy
0.25 % of span.
Span Temperature Coefficient
0.05 % / C for process temperature variation.
0.01 % / C for ambient temperature variation.
Operating Range
-5 to + 60 C.
Overpressure
Up to two times the full scale pressure.
Power Supply
14 Vdc minimum; 45 Vdc maximum (2-wire system).
Pneumatic Connection
Union for flexible hose.
Case
Extruded anodized aluminum.
Dimensions
91 x 44 x 150 mm nominal (HxWxD).
Weight
0.5 kg nominal.
Warranty
One year.

Dimensional

Dimensional Drawing (only for mounting in protected place)

presys

Electropneumatic
Converter
(I/P) Weather-proof
TY-1125-TEM
Model with weather-proof box for field mounting.
Specifications

Order Code:
TY-1125-TEM
Model
Input
4/20 - 4 to 20 mAdc.
10/50 - 10 to 50 mAdc.

Output
3/15 - 3 a 15 psi.
3/27 - 3 a 27 psi.

Accessories
Y1
Y3
Y4
Y5
Y6

Mounting device 2 inch tube.


Filter with pressure regulator and pressure gauge.
Filter.
Pressure regulator.
Pressure gauge.

Code Example
TY-1125 - TEM - 4/20 - 3/15 - Y1.
Defines a current to pressure converter for mounting in 2 inch
tube, in weather-proof box with 4-20 mA input and 3-15 psi
output.

Air Supply
1.6 scfm.
Pneumatic Supply
20 psi for 3-15 psi output, 30 psi maximum.
37 psi for 3-27 psi output, 40 psi maximum.
Air Demand
0.08 scfm.
Accuracy
0.5 % of span.
Repeatability
0.25 % of span.
Linearity
Less than or equal to 0.5%.
Hysteresis
Less than or equal to 0.2 %.
Temperature
-40 C + 80 C.
Connection
Cable gland Pg 9 (cable diameter: 4-10 mm) electrical part,
1/4 NPT pneumatic part.
Warranty
One year.

Dimensional

NOTA: The filter regulator is coalescent type, of less than


5 microns, and therefore, suitable for use with TY-1125
converters.
WARNING: Be careful with the compressed air, make sure
it is within the standards for instrumentation.

31

presys

Virtual Recorder VR-2000 - 3.3

RECORDER and DATA-LOGGER simulator software.


Circular graphics printing with the same look of
traditional physical recorders. Also offers online
and historical trend graphs.

Receives signals for register of any instrument of


line 2000, mainly DMY-2015, DMY-2015-DLY,
TY-2095 and TY-2095-DLY.

It offers extensive and advanced set of functions of


DATA-LOGGER and EVENTS RECORDER.

Compatible with Windows XP or higher, 32/64 bits.

32

presys
Simple to install, easy to use.

Example of VR-2000 use with the TY-2095 measuring 12 temperature


points from thermocouple inputs. It can simulate 12 records of a pen each
or 6 records of two pens, or any desired combination.

As a Data-Logger, operating together with the DMY-2015-DLY,


it allows configuration and acquisitions in field with posterior data
recovery to export in spreadsheet and visualization graphics.
Incorporates the configurator module of the Line 2000 instruments, COMFYS-2.2.

Specifications
Process monitoring through trend charts and circular;
Allows bargraphs viewing;
View data saved in disk or database;
Allows programming, collection and acquisitions viewing together
with the DMY-2015-DLY / TY-2095-DLY;
Allows online configuration of the Line 2000 instruments,
backup and configuration recovery;
MODBUS (RS-232/TCP) Communication Protocol;
Data export to spreadsheet;
Generates and saves alarm events;
It has user access control system.

COMFYS-2.2.
Allows remote configuration of the Line 2000 Presys instruments via
MODBUS RTU / TCP (requires converter);
It also allows the reading and storage of an instrument configuration,
as well as the subsequent reloading of it.
Available as a free download for use together with
Presys Instruments in our website.
Compatible with Windows XP or higher 32/64 bits.
33

presys

Multi-Loop Data-Logger
Module

DMY-2015-DLY
Available inputs for DMY-2015-DLY and TY-2095-DLY:
- 12 thermocouple inputs.
- 8 RTD inputs.
- 12 current inputs 4-20 mA.
- 12 voltage inputs 1-5 Vdc.
- Combinations of two types of input.

Several optional are available:

TY-2095-DLY
Data Logger function for storage of up to
256 000 readings.

High level of accuracy. RTD and thermocouple

linearization; square root extraction for mA and V


inputs.

DMY-2015-DLY: 4-digit display of high


visibility and 2-digit display to indicate the

- 2 alarm modules with SPDT relay.

channel. Fully configurable from the front panel.

- Aspersion-proof front panel.

ACK button.

- RS-232 or RS-422/485 communication.

TY-2095-DLY: DIN rail or surface mounting.


Configurable via serial communication or
through configuration module.

34

presys
Order Code

Model

DMY-2015-DLY
TY-2095-DLY

Inputs

0 - 12 thermocouples
1 - 8 RTD
2 - 6 thermocouples and 4 RTD
3 - 12 current mA
4 - 12 voltage V
5 - 6 thermocouples and 6 current mA
6 - 6 thermocouples and 6 voltage V
7 - 6 current mA and 6 voltage V
8 - 6 current mA and 4 RTD
9 - 6 voltage V and 4 RTD

Output 1

0 - None
1 - SPDT Relay
2 - Open Collector Voltage
3 - Solid State Relay

Output 2

Same code as Output 1

Power Supply
1 - 75 to 264 Vac 50/60 Hz or 100 to 360 Vdc (any
polarity)
2 - 24 Vac or 24 Vdc (10 %)
3 - 12 Vdc (10 %)
4 - Other, upon request

Communication
0 - None
1 - RS-232
2 - RS-485
3 - RS-422

Case Protection Grade


DMY-2015-DLY:
0 - General usage, protected place
1 - Front Aspersion-proof
2 - Weather-proof - IP 66
TY-2095-DLY:
0 - General usage, protected place, surface mounting
1 - General usage, protected place, DIN rail mounting
2 - Weather-proof - IP 66
3 - Dust-proof

Specifications
Inputs
Thermocouple (J, K, T, E, R, S under ITS - 90).
RTD Pt-100 under DIN 43760.
4-20 mA, 250 input impedance.
1-5 Vdc, input impedance >10 M.
Outputs
Two SPDT relay modules rated for 3A/220 Vac.
Logic signal, open collector transistor, 24 Vdc/40 mA
maximum with isolation. Solid state relay,
2A/250 Vac with isolation.
Serial Communication
RS-232 or RS-422/485 with 50 Vdc isolation.
MODBUS-RTU Communication Protocol.
Indication
DMY-2015-DLY: 4-digit red leds display (14 mm),
that can be configured together with the decimal point.
TY-2095-DLY: without local indication.
Configuration
DMY-2015-DLY: by front panel push buttons.
TY-2095-DLY: through the MCY-25 portable configurator.
Sampling Rate
660 ms standard, for all inputs. One second display update rate.
Accuracy
0.1 % of full scale for TC, RTD, mA, and Vdc.
Linearization
0.1 C for RTD and 0.2 C for TC.
Square Root Extraction
0.5 % of reading, for input above 10 % of span.
Programmable Cut-off from 0 to 5 %.
Cold Junction Compensation
2.0 C in ambient temperature range from 0 to 60 C.
Span Temperature Coefficient
0.005 % of span / C using 25 C as the reference temperature.
Power Supply
75 to 264 Vac 50/60 Hz or 100 to 360 Vdc
(10 W nominal); 24 Vac/dc (10 %); 12 Vdc (10 %).
Operating Range
0 to 60 C temperature and 90 % maximum relative humidity.
Dimensions
DMY-2015-DLY: 1/4 DIN (96 x 96 x 187 mm) HxWxD, (92 x 92 mm) HxW
panel cutout.
TY-2095-DLY: (140 x 93 x 173 mm) HxWxD.
Weight
0.7 kg nominal.
Warranty
One year.

35

presys

Data
Acquisition
Module
TY-2095 and
TY-2095-PB

Available models:
- 12 thermocouple inputs.
- 8 RTD inputs.
- 12 current 4-20 mA inputs.
- 12 voltage 1-5 Vdc inputs.
- Combination of two input types.

Eight voltage or current inputs totalization.


Available optionals:
- Up to two SPDT relay alarm modules.
- RS-232, RS-422/485 Communication (MODBUS RTU Protocol) or PROFIBUS (DP-V0)*.

Features DIN rail or surface mounting.


High level of accuracy. RTD and thermocouple linearization; square root extraction for mA and V inputs.
Configurable via serial communication or through portable configurator.

*Available only for the model TY-2095-PB


36

presys
Order Code

Model
TY-2095
TY-2095-PB

Inputs
0 - 12 thermocouples
1 - 8 RTD
2 - 6 thermocouples and 4 RTD
3 - 12 current mA
4 - 12 voltage V
5 - 6 thermocouples and 6 current mA
6 - 6 thermocouples and 6 voltage V
7 - 6 current mA and 6 voltage V
8 - 6 current mA and 4 RTD
9 - 6 voltage V and 4 RTD

Output 1
0 - None
1 - SPDT Relay
2 - Open Collector Voltage
3 - Solid State Relay

Output 2
Same code as Output 1

Power Supply
1 - 75 to 264 Vac 50/60 Hz or 100 to 360 Vdc (any
polarity)
2 - 24 Vac or 24 Vdc (10 %)
3 - 12 Vdc (10 %)
4 - Other, upon request

Communication
0 - None
1 - MODBUS (RS-232)*
2 - MODBUS (RS-485)*
3 - MODBUS (RS-422)*
4 - PROFIBUS DP-V0 (RS-485)**

Case Protection Grade


0 - General usage, protected place, surface mounting
1 - General usage, protected place, DIN rail mounting
2 - Weather-proof - IP 66
3 - Explosion-proof (Ex d IIB T6 Gb 66), without display***
4 - Dust-proof

Specifications
Inputs
Thermocouple (J, K, T, E, R, S under ITS - 90).
RTD Pt-100 under DIN 43760.
4-20 mA with input impedance of 250 .
1 to 5 Vdc with input impedance >10 M.
Outputs
Up to 2 SPDT relays rated for 3A/220 Vac.
Logic signal, open collector transistor, 24 Vdc/40 mA
maximum with isolation. Solid state relay,
2A/250 Vac with isolation.
Serial Communication
TY-2095: RS-232 or RS-422/485. MODBUS-RTU
Communication Protocol.
TY-2095-PB: PROFIBUS DP-V0: RS-485.
Indication
Without local indication. Maximum range from -999 to 9999
viewed through the MCY-25 Configuration Module.
Totalization
Totalization of eight voltage or current inputs ranging from
0 to 9999, configured with the decimal point.
Configuration
Through MCY-25 portable configurator.
Sampling Rate
480 ms standard, for all inputs. One second display update rate.
Accuracy
0.1 % of full scale for TC, RTD, mA, Vdc.
Linearization
0.1 C for RTD and 0.2 C for TC.
Square Root Extraction
0.5 % of reading, for input above 10 % of span.
Programmable Cut-off from 0 to 5 %.
Cold Junction Compensation
2.0 C in ambient temperature range from 0 to 60 C.
Span Temperature Coefficient
0.005 % of span / C using 25 C as the reference
temperature.
Power Supply
75 to 264 Vac 50/60 Hz or 100 to 360 Vdc
(10 W nominal); 24 Vac/dc (10 %); 12 Vdc (10 %).
Operating Range
0 to 60 C temperature and 90 % maximum relative humidity.
Dimensions
140 x 93 x 173 mm HxWxD.
Weight
0.7 kg nominal.
Warranty
One year.

* Only available for the model TY-2095


** Only available for the model TY-2095-PB
*** Explosion-proof box:
Dimensions
310 x 310 x 200 mm (HxWxD)
Weight
11 kg nominal

37

presys

Accessories
Analog Output Module MSAN-20
Generates 4-20 mA, 1-5 Vdc, 0-10 Vdc signals. For use as a control
output or retransmitter output of the process variable.

Relay Output Module MALRE-20


Electromechanical relay for use in control or alarm, current up to 3A
in 220 Vac. It has RC circuit (snubber) to eliminate the noise
caused by contacts opening / closing . Depending on the application,
this snubber must be disabled to allow the passage of a little AC current.

Solid State Relay


Output Module MALRS-20
Semiconductor relay for current up to 1A. Suitable for inductive
loads, especially solenoids and contactors. It can not be used in
direct current.

Pulsed Output Module MSD-20


Also called Logic Output or Open Collector Output.
Generates 24 V voltage signal in PWM. Used to
activate external power units such as thyristor unit.

RS-232 Communication
Module MCOM RS232
RS-232 interface for communication for connecting
one single instrument to the computer. Maximum
distance 15 meters.
38

presys
RS-485Communication
Module MCOM RS-485
RS-485 Communication Interface, to connect up to
31 instruments in a network with the computer.
Maximum distance 1200 meters.

Power Filter FLAY-02


Used when the mains power signal has
great intensity of high frequency noise.

Filter for Input


Signal FLSY-03/FLSY-06
With three or six pins, for filtering electrical noise
present in the input signal.

External Thyristor
Power Unit MTY-48D10
Used for controlling loads up to 10 Aac. It is necessary
that the instrument has the Open Collector Module MSD-20.
Other types of thyristor unit are available on request.

Configurators

MCY-20/MCY-25/MCY-55
For use with instruments TY-2090, TY-2095,
DCY-2055. It allows its configuration by
keyboard and display.

Converter Unit

RS-232/485UNICONV232/485
Used for a network connection of the
instruments to the computer serial port.

39

Explosion-proof
Panel for
Line 2000
Instruments

The Presys Explosion-proof box was especially developed for instruments used in the
Industrial Process as Indicators, Controllers and Transmitters.

Main Features:
- Applicable in area of explosive atmosphere, consisting of combustible gases,
classified as Zone 1 Group IIB.
- Fully protected against dust and water jets.
- Certificate of Conformity to Electrical Equipment for Potentially Explosive Atmospheres,
by IEE-USP and TV RHEINLAND, with the marks Ex d IIB T6 Gb IP66.
- Fully programmable by the front panel push-buttons, via serial communication or
through portable configurator as specified model.

40

presys
Explosion-proof Models with Horizontal Display
DMY-2030, DMY-2030-F, DMY-2030-TOT, DMY-2030-TOT-F, DMY-2030-Light, DMY-2030-F-Light, DMY-2030-TOT-Light,
DMY-2030-TOT-F-Light, DMY-2030-CC, DMY-2030-CV, DMY-2030-TOT-FCS, DMY-2031-FCS, DMY-2036, DMY-2036-F,
DMY-2011, DMY-2011-F, DMY-2015, DMY-2015-PB, DCY-2051, DCY-2051-F, DCY-2051-Light, DCY-2051-F-Light,
DCY-2051-LC, DCY-2059, DCY-2060, DCY-2060-F, DCY-2060-Light, DCY-2060-F-Light, DCY-2060-LC.
Explosion-proof Models with Vertical Display
DMY-2035, DMY-2035-F, DCY-2050, DCY-2050-F, DCY-2050-Light, DCY-2050-F-Light, DMY-2050-LC, DCY-2058.

200mm

140mm

15mm(x4)

Explosion-proof Models Without Display


DCY-2055, TY-2090, TY-2090-F, TY-2095.

310mm

275mm

A M

Horizontal Display

Vertical Display

Without Display

NOTE: Command buttons with mounting option for 1, 2, 3, 4 buttons or none.

Threaded Entrances Layout.

POSITION

80mm

NOMINAL
(NPT)

3/4"
1"
1.1/4"
1.1/2"

C
ORDER CODE EXAMPLE: EXPLOSION-PROOF INDICATOR

DMY-2030 - 0 - 0 - 0 - 0 - 1 - 0 - 3 (G3/4 + H1 + I3/4)

CHOSEN POSITIONS

CASE PROTECTION GRADE


SERIAL COMMUNICATION
POWER SUPPLY
OUTPUT 4
OUTPUT 3
OUTPUT 2
OUTPUT 1

MODEL

41

presys

Dimensional

Drawings

Models: TY-2090 and DCY-2055


DIN rail adapter

GND Terminal

26.5 mm

148.5 mm

140 mm

91 mm

130.5 m m

Terminal block

4.5 mm

175 mm

53 mm

Side View

Front View

Models: TY-2095/ TY-2095-PB/ TY-2095-DLY


DIN rail adapter

26.5 mm

146.5 mm
173 mm

Side View
42

93 mm

Front View

140 mm

91 mm

GND Terminal

4.5 mm

130.5 mm

Terminal block

presys
1/4 DIN Models
DMY-2011, DMY-2015, DMY-2015-PB, DMY-2015-DLY, DMY-2017,
DMY-2017-Light, DCY-2057, DCY-2060, DCY-2060-LC and DCY-2060-Light

91 m m

96 mm

12 mm

26,5
mm

148.5 mm

Front View
GND Terminal

187 mm

92 mm - 0.0

+0.8

Side View

Panel Cutout(*)

1/8 DIN Models with Vertical Orientation


DMY-2035, DCY-2050, DCY-2050-LC, DCY-2050-Light and DCY-2058

148.5 mm
187 mm

26.5
mm

GND Terminal

Side View

Front View

+0.6

92 m m - 0.0

+0.8

45 mm - 0.0

44 mm

12 mm

96 mm

91 mm

48 mm

Vista Superior
(*)Maximum panel thickness: 10 mm

Panel Cutout (*)


43

presys
1/8 DIN Models with Horizontal Orientation
DMY-2030, DMY-2030-Light, DMY-2030-TOT, DMY-2030-TOT-Light, DMY-2030-CC,
DMY-2030-CV, DMY-2031-FCS, DMY-2030-TOT-FCS, DCY-2051, DCY-2051-LC,
DCY-2051-Light, DCY-2059 and DMY-2036

48 mm

44 mm

96 mm

Side View

Front View

+0.8
- 0.0

45 mm

+0.6
- 0.0

91 mm

92 mm

Panel Cutout(*)
26.5
mm

148.5 mm

12 mm

GND Terminal

187 mm

Upper View

Model: DMY-2032

20 mm

140 mm

26.5
mm

GND Terminal

130 mm

91 mm

235 mm

Front View

186.5 mm

92 mm - 0.0

+0.8

Side View

(*)Maximum panel thickness: 10 mm

44

Panel Cutout(*)

presys
Weather-proof Models - IP 66
180 mm

INSTRUMENT FIXING
SUPPORT
TRANSPARENT
COVER

155 mm

DISPLAY
(1/8 or 1/4 DIN)
PR E SYS
LD2

245 mm

270 mm

LD1

INSTRUMENT
(1/8 OR 1/4 DIN)

SIDE VIEW

FRONTAL
VIEW

2 PG9 CABLE GLAND


ELECTRICAL INPUTS

DRILLING FOR WALL FIXING

45 mm

171 mm

126 mm

USE SCREW DIAMETER = 6.0 mm


SCREW HEAD MAXIMUM DIAMETER = 10.0 mm
MINIMUM LENGTH = 30.0 mm

BOX FOR WALL FIXING

UPPER VIEW

CLAMP

2 TUBE

CLAMP
2 TUBE

223.5 mm

SUPPORT

223.5 mm

SUPPORT
ASSEMBLY WITH 2 " TUBE SUPPORT
HORIZONTAL AND VERTICAL

45

presys

HART Field
Communicator

FCY-15

Hart Configurator, with DD library, configures device specific parameters.


25 Vdc Power supply for 2-wire transmitters.
Configurable 250 internal resistor.
5.7'' high visibility touch screen display.
Portable, powered by rechargeable batteries for field use.
Configurador Hart Full.
USB software update.

46

Instrumentos e Sistemas

EMENT SYS
AG

Calibrao
NBR ISO/IEC
17025

QUA ITY
L

CAL 0193

M
TE

PRESYS

Rua Luiz da Costa Ramos, 260


So Paulo - SP - 04157-020
Tel: (11) 3056.1900
Fax: (11) 5073.3366
http://www.presyscorp.com
E-mail: vendas@presys.com.br

MA
N

Instrumentation and
Process Control

OCP 0004

EF-0241-01