Ibexu 04 Atex 1125 X
Ibexu 04 Atex 1125 X
Ibexu 04 Atex 1125 X
UNCERTIFIED TRANSLATION
[1]
[2]
[3]
[4]
Equipment:
[5]
Applicant:
[6]
Address:
Am Bahnhof 30
D-74638 Waldenburg
[7]
This equipment specified under [4] and any acceptable variation thereto is specified in
the schedule to this certificate, and the documents therein referred to.
[8]
IBExU Institut fr Sicherheitstechnik GmbH, notified body number 0637, in accordance with Article 9 of the Council Directive 94/9/EC of 23 March 1994, certifies that
this equipment has been found to comply with the Essential Health and Safety Requirements relating to the design and construction of equipment intended for use in
potentially explosive atmospheres given in Annex II to the Directive.
The test results are recorded in report IB-04-3-162 of 02.06.2004.
[9]
Compliance with the Essential Health and Safety Requirements has been assured by
compliance with EN 50281-1-1-1999.
[10]
If the sign X is placed after the certificate number, it indicates that the equipment is
subject to special conditions for safe use specified in the schedule to this certificate.
[11]
This EC-Type Examination Certificate relates only to the design and construction of
the specified equipment. If applicable, further requirements of this Directive apply to
the manufacture and supply of this equipment.
[12]
IBExU04ATEX1125 X
e II 2D T80C IP 66
(signature)
(Dr. Lsch)
Schedule
Page 1 of 3
IBExU04ATEX1125 X
Schedule
[14]
[15]
Description of equipment
The miniature limit switch Type 8064/2. is used as an auxiliary switch for signal control circuits and is designed for use in areas with combustible dust Zone 21 and Zone
22. It will comprise one or two interrupting chambers. The connection is provided by
means of an encapsulated connecting cable (open ended line).
Type designation
Miniature limit switch
Type series
Type attachment
Connecting cable = 2
Contact gap
short opening travel
(2 x 0,3 mm snap-action contact)
=1
=8
up to 500 V
400 V
250 V
2A
0,15 A
AC-15
DC-13
1 (single or double)
IP 66
Protection by enclosure
-55C to +75C
Test Report
The test results are set down in the test report IB-04-3-162 of 02.06.2004
The test and information documents are components of the test report and are presented there
Page 2 of 3
IBExU04ATEX1125 X
[17]
The manufacturer is under an obligation to carry out routine tests and the required
test for meeting the explosion proofness regulations for the miniature limit switch
Type 8064/2. in accordance with EN 50014-1997 + A1 + A2, section 24.
The quality of the connection cable shall satisfy the thermal and mechanical requirements within the functional range. If the connecting cable is not shielded, the
connecting cable must be protected from damage. The partly limit temperature
range of the cable (max. 70 C) has to be taken into account.
Special Conditions
-
The miniature limit switch Type 8064/2. shall be installed in such way, that the
mechanical protection against impact energy in accordance with EN 50014 section 23.4.3.1 is always guaranteed.
The open ends of the connecting cable are to be protected according to the requirements of the dust explosion protection (e.g. terminal box IP 6X).
The maximum surface temperature T 80 C is valid for the following ambient temperatures and maximum currents:
ambient temperature
rated thermal current
one interrupting chambers
rated thermal current
two interrupting chambers
[18]
60 C
75 C
7A
3A
6A
2A
By order
(signature)
(Dr. Lsch)
Page 3 of 3
IBExU04ATEX1125 X