Lab Viva Question
Lab Viva Question
Lab Viva Question
The magnetic field in a d.c generator is normally produced by an electromagnets rather than
the permanent magnets.
On the basis of field excitation, generators are classified into two types, namely
1.separately excited d.c. generators
2.self excited d.c. generators
4. Give the classification of self excited generators based on the field winding
connected to the armature
Based on the field winding connected to the armature, the self excited generators are
classified into three types
(i)series generator
(ii)shunt generator
(iii)compound generator
1.
Clockwise when viewed from the end opposite to the driven end
2.
It means the gradual increase in the generator voltage to its maximum value after the
generator is started from rest
3.
4.
5.
Give the classification of self excited generators based on the field winding
connected to the armature
Based on the field winding connected to the armature, the self excited generators are
classified into three types
(i)series generator
(ii)shunt generator
(iii)compound generator
2. What will happen if both armature and field currents are reversed?
The motor will run in original direction
5. What will happen if a shunt motor is directly connected to the supply line?
The motor will damage
A compound wound motor has two field windings; one is connected in parallel with the
armature and the other is in series with the armature.
4.A Metallic Sphere Is Charged Negatively. Will Its Mass Increases, Decreases Or
Remains Same?
When sphere is negatively charged, it means electrons have been added to it, since
electrons has finite mass, the mass of the negatively charged sphere will increase.
5.suggest a method to determine the power factor by using various meters available.
Use an ammeter, voltmeter, wattmeter to measure the RMS current in the circuit, the rms
voltage across the circuit and the average power delivered are found. From this the power factor
is found.
1.
In a dc series motor flux per pole depends upon the armature current. If the load
decreased, armature current and flux per pole is decreased. Consequently, the speed of
the motor may rise may rise to dangerously high values. For this reason, we never
permit a dc series motor to operate on no loads.
2.
If current direction through a series motor is reversed, the polarities of the field poles and
the armature conductors both are reversed, resulting in a pushing effort between them in
the same direction. Because of this, series motor operate on ac supply.
In a dc motor, TIA. For a dc series motor. At first IA. So that TaIA2. If current
increases two-fold, Then the torque increases four fold. So starting torque of motor is
very high. So it is used to start at heavy loads.
5. The Element Of A Heater Is Very Hot While The Wires Carrying Current
Are Cold. Why?
Heat produced depends upon the resistance of the conductor. The elements (made of
nichrome) of the heater is very hot due to its high resistance while the lead wires are
cold due to its low resistance.
4. Incorrect voltage
1.What is a transformer?
It is a static device, which transfers power from one circuit to other circuit without any
change in frequency.
N2
I1
N1
I2
causes
The iron losses are minimized by using high grade core material like silicon steel
having very low Hysteresis loop and manufacturing the core in the form of
laminations.
REVIEW QUESTIONS:
1.Give the condition for maximum efficiency of the transformer.
Copper loss=Iron loss
The ratio of output in kWh of a transformer over a 24-hour period is known as all day
efficiency.
all-day=
kWh output in 24 hours
KWh input in 24 hours
5.How will you reduce the eddy current loss in the core?
By having laminated core the area of the core can be reduced thereby reducing the eddy
current loss.