Read Med
Read Med
Read Med
Plus.
Note: Please switch off HighScore or HighScore Plus while installing the PAN-ICSD!
The PAN-ICSD has become a search-match (reference) database.
A direct link between reference patterns and corresponding structure data exists, there is
no need to export / import .CIF or .CRY files.
No time-limit on the PAN-ICSD (use as long as you like) license.
The PAN-ICSD is not bound to a single PC (usage on multiple PCs within one
department is possible, but customers need to obey to the restrictions for analysis
software from PANalytical).
Possibility to use it either in combination with ICDD PDF products or stand-alone.
No upgrades are available (only complete new releases are sold).
The retrieval software "FindIt" is not part of the PAN-ICSD, use HighScore (Plus)
reference pattern retrieval functions instead.
The PAN-ICSD now contains subfile information (User Inorganic, User Metallic, User
Mineral, User Organic).
Using the PAN-ICSD database is explained in the help system of HighScore (Plus) and in the
help file PANICSD.chm, which is in the installation directory of the PAN-ICSD database.
1.
2.
Operating Systems
The PAN-ICSD database is designed and tested for the Windows XP 32-bit / Windows 7 64-bit
operating systems. It might run under Windows VISTA too, but this was never tested. The Internet
Explorer v.6.0 or higher is required to support XRDML files and to view the help system.
Recommended configuration
Operating system
Windows 7 64-bit professional operating system
Processor
Pentium 5 or compatible, 2 GHz (or faster)
Internal memory
2 Gbytes (2-4 Gbytes for simultaneous analysis of many scans as in
screening experiments)
Free hard disk space ~2 Gbytes
Monitor
Super VGA monitor (17 inch or more) with a desktop area of 1024*768
pixel.
Minimum configuration
To run the software a PC configuration that meets the (minimum) hardware requirements for the
Windows operation system will be sufficient.
For Windows XP Professional edition (32-bit), see
http://support.microsoft.com/kb/314865;
for Windows Vista Business edition (32-bit), see
http://support.microsoft.com/kb/919183;
for Windows 7 (64-bit) operating systems, see
http://windows.microsoft.com/en-us/windows7/products/system-requirements.
3.
Installation
1. If your disk drive is not configured for "Autoinsert" notification, start "Setup.exe" from the
root folder on the DVD.
2. Select "Custom Installation" if you want to change the folder the software is installed in.
3. It is a good idea to defragment the target drive before installing the PAN-ICSD.
4. Since the PAN-ICSD can only be used in combination with the HighScore (PW3209) or
5.
6.
4.
4. The reference numbers for existing structures are fixed now and do not change from
release to release.
5. The PAN-ICSD now contains subfile information (User Inorganic, User Metallic, User
Mineral, User Organic).
The database contents changed due to revisions and editing by FIZ / NIST.
5.
Known inconveniences
The following structures have no stick diagrams associated, because they could not be converted
into a reference pattern, but they can be opened with their collection code:
56190; No scattering data found for: T1