LPOD-R C-, X- or Ku-Band Block Up Converter (BUC)/SSPA

Amplifiers

Model PS .5

Model PS 1

Model PS 1.5

Overview
Our LPOD-R family of Outdoor Amplifiers / Block Up Converters (BUCs) deliver rated power, guaranteed, to the transmit waveguide
flange at the 1 dB compression point. The LPOD-R is a cost-effective alternative to the LPOD, where the full LPODs support of internal
10 MHz and redundancy is not required. There are three LPOD-R models available PS .5, PS 1 and PS 1.5.
Each LPOD-R consists of a SSPA module with the Monitor/Control Processor (MCP), a power supply and a fan assembly. To ensure
the maximum usable output power with stable operation over a wide range of environmental conditions, the units feature a low loss
combining technique and MCP-based temperature-versus-gain compensation. The LPOD-R units are compact in size and weight,
lending itself to installations with limited available mounting space. Common installations for the LPOD-R are ship-borne antenna
systems, small flyaway systems, and Satellite News Gathering (SNG) vehicles.

Data Logging Capability


To greatly enhance system maintainability, the LPOD-R line includes a built in data logging capability. By recording critical operational
parameters (such as temperature, output power, mute status, etc.) at time stamped intervals, the user can quickly gather intelligence
not only about the unit itself, but also the units operational environment.

Enhanced Standard Features


The LPOD-R comes equipped with useful features that other manufacturers offer only as options. Included in the base price are
temperature compensation, power monitor, power factor corrected supply, and flexible remote monitor and control (M&C) capabilities.

Monitor & Control


The LPOD-R features flexible, remote monitor and control (M&C) capabilities that are unique to the industry.
Advanced FSK When used with our modems the LPOD-R provides enhanced functionality utilizing the industry-standard FSK
communications channel. Advanced FSK offers full control of single thread and, where applicable, redundant systems from the
modem front panel without additional cabling or cost. The LPOD-R can also be
accessed via the Ethernet M&C port of the modem and controlled via Embedded
Distant-end Monitor and Control (EDMAC).
Ethernet By using the Ethernet port on the LPOD-R, the unit can be controlled via a
web-based graphical user interface, Telnet and SNMP.
NetVue Integrated Management System The units can be managed by our
NetVue, which provides the level of network insight required to run optimal networks.
NetVue provides a single intuitive graphical user interface that acts as a user-friendly
front-end to monitor and control network equipment. It features a robust,
comprehensive network management and analytics engine that allows users to
intelligently maximize resources, ensure network uptime and provide the elevated
levels of service that are required to support fixed and remote sites in the field.
Optimized Efficiency The low power consumption (60W Nominal) of the LPOD R
Figure 1: NetVue Integrated
PS.5 10W Ku and 12W C band overcomes the BUC power limitations found in many
Management System
TDMA modems. This provides a very cost effective and convenient path to increased
throughput and link availability.

Solid State Advantage


Our extensive experience in the design of outdoor RF transceivers led to the LPOD familys efficient thermal and mechanical package.
The LPOD-R is constructed with highly reliable gallium arsenide field-effect transistors (GaAs FETs). With third-order intermodulation
products that are 4 to 6 dB better than TWT ratings, the CEFD unit replaces TWTs with saturated power levels of up to twice the
LPOD-Rs rated output. The LPOD-R also provides mean time between failures (MTBF) that is four to five times greater than the typical
TWT MTBF.

www.comtechefdata.com

Specifications
IF Input Frequency Note 1
950 1525 MHz
950 1750 MHz
950 1825 MHz
965 1265 MHz
950 1450 MHz
950 1450 MHz
950 1750 MHz
Model
PS.5-10Ku
PS.5-15Ku
PS.5-20Ku
PS1-20Ku
PS1-32Ku
PS1-40Ku
PS1.5-50Ku
PS1.5-60Ku
PS.5-15C
PS1-25C,X
PS1-32C,X
PS1-40C,X
PS1-50C,X
PS1-60C,X
PS1.5-75C,X
PS1.5-80C,X
PS1.5-100C,X
PS1.5-110C,X
PS1.5 -125C,X

RF Output Frequency
5.850 6.425 GHz
5.850 6.650 GHz (optional)
5.850 6.725 GHz (optional)
6.725 7.025 GHz
7.900 8.400 GHz
14.00 14.50 GHz
13.75 14.50 GHz (optional)

Psat (Typical)
40dBm (10 W)
41 dBm (15 W)
43 dBm (20 W)
43 dBm (20 W)
45 dBm (32 W)
46 dBm (40 W)
47 dBm (50 W)
48 dBm (60 W)
41 dBm (15 W)
44 dBm (25 W)
45 dBm (32 W)
46 dBm (40 W)
47 dBm (50 W)
48 dBm (60 W)
48.6 dBm (75 W)
49 dBm (80 W)
50 dBm (100 W)
50.4 dBm (110 W)
51 dBm (125 W)

Gain Min. (Typical)


All power levels
Max. IF Input level (no
damage)
Gain Adjust
Gain Flatness

Gain variation over temp


Input Return Loss
Output Return Loss
Noise Figure
RF Mute Isolation
AM/PM Conversion
3rd Order Intermod. Level
(2 tones, @ -3 dB Total Back
Off from P1 dB (-6 dBc
SCL), 1 MHz)

P1dB (Guaranteed)Note 1
39 dBm (8 W)
40 dBm (10 W)
42 dBm (16 W)
42 dBm (16 W)
44 dBm (25 W)
45 dBm (32 W)
46 dBm (40 W)
47 dBm (50 W)
40 dBm (10 W)
43 dBm (20 W)
44 dBm (25 W)
45 dBm (32 W)
46 dBm (40 W)
47 dBm (50 W)
48 dBm (60 W)
48.5 dBm (70 W)
49 dBm (80 W)
49.5 dBm (90 W)
50 dBm (100 W)

PS .5: 60 ( 65 dB), optional 70 (75 dB)


PS1, 1.5: 70 (75 dB)
+10 dBm
20 dB in 0.25 dB steps
2.0 dB full band (optional 2.5 dB full
band (-50 to +55C))
0.50 dB per 40 MHz (optional
1.0 dB per 40 MHz (-50 to +55C)
2.0 dB max., -40 to +55C
(optional 2.5 dB max. (-50 to +55C))
14 dB (1.5:1 VSWR)
17.7 dB (1.3:1 VSWR)
15 dB typ., 20 dB max. @ min.
attenuation
-60 dBc min.
2 typ., 3.5 max. @ Rated P1dB
-30 dBc typ., -25 dBc Guaranteed

Spurious Level
Harmonics
Carrier Related In-band
Non-Carrier Related In-band
LO Leakage

-50 dBc @ Prated -3dB


-60 dBc min. @ P1dB
-60 dBm max. (Input Terminated)
-25 dBm max.

Group Delay
Linear
Parabolic
Ripple

0.03 ns/MHz
.003 ns/MHz2
1.0 ns pk-pk

Data Logging parameters

Phase Noise (dBc/Hz)


Offset = 100 Hz
1 KHz
10 KHz
100 KHz
1 MHz

Non-Volatile RAM: Capacity 30 days @


90 minute intervals.
Includes:
RF Output Power
Mute Status
Heatsink Temperature

Typical (C/X/Ku)
-65
-75
-85
-95
-105

Spec (C/X/Ku)
-62
-72
-82
-92
-102

Environmental & Physical


Temperature
Operating

-40 to 131F (-40 to 55C)


(optional -50 to 55C or -40 to +60C)
-67 to 167F (-55 to 75C)
Designed to meet IP-66 (Dust tight, protected against
strong water jets)
100% condensing rain 2 per hour
10,000 AMSL
Normal commercial shipping and handling

Storage
Ingress
Protection
Humidity
Altitude
Shock
Input Voltage
PS .5 (10 W Ku/12 W C) 18 to 60 VDC, 60 W Nominal
PS .5 (20 W Ku)
18 to 60 VDC,110 W Nominal
PS.5 (Other Powers)
36 to 72 VDC
PS1, 1.5
90 to 240 VAC, 36 to 72 VDC
Weight / Dimensions (height x width x depth (in. excluding connectors))
PS .5
6 lbs Nominal / 3.3 x 4.65 x 7.7
PS1
14 lbs Nominal / 6.2 x 6.0 x 12.65
PS1.5
17 lbs Nominal / 6.5 x 6.2 x 12.8
Connectors
IF/RF Input Type N, female
Optional Type F, female (PS.5)
PS.5/1, C-Band: Type N, female, opt. CPR137G
PS1.5, C-Band: CPR137G
RF Output
PS1/1.5 X-Band: CPR112G
PS.5/1/1.5/ Ku-Band: WR75G
Supported
Ethernet (includes built-in HTML pages, SNMP, Telnet)
Interface
Standard Smart BUC FSK
Advanced FSK (provides full front panel control when
integrated with select Comtech EF Data modems)

Note:
1. Allow 1 dB degradation from 13.75 to 14.0 GHz and 6425 to 6725 MHz

2114 West 7th Street, Tempe, Arizona 85281 USA


Voice: +1.480.333.2200 Fax: +1.480.333.2540 Email: sales@comtechefdata.com
See all of Comtech EF Datas Patents and Patents Pending at http://patents.comtechefdata.com
Comtech EF Data reserves the right to change specifications of products described in this document at any time without notice and without obligation to notify any person of such changes. Information in
this document may differ from that published in other Comtech EF Data documents. Refer to the website or contact Customer Service for the latest released product information
2016 Comtech EF Data
ds-lpod-r.docx
2/19/2016

You might also like