Accutech TM10 Datasheet Letter
Accutech TM10 Datasheet Letter
Accutech TM10 Datasheet Letter
Accutech TM10
Functional
Sensor Type
Location
Field Unit
Frequency Range
Power
Integrated battery
Network Capacity
Features
Remote Configuration
Interface
Accutech Manager, WindowsTM-based GUI software, providing network-wide fault and performance-management features and
field unit configuration capabilities
Turbine Meter
Electronic Accuracy
and Stability
Flow Rate accurate to 0.01% of reading (not including turbine meter and pickup)
Applies to all pulse frequencies above low cut-off of 1Hz
Physical Connection
1in. female NPT connection to Turbine Meter Union for easy removal, pickup installation and replacement
Magnetic Pickup
Two-wire, connector supplied. See supported model numbers in the Sensor Pickup section of the model code
Frequency Range
1Hz. to 10KHz
RF Characteristics
Self-Diagnostics
Low battery alarm indicates the need to replace the battery (approximately one month warning)
Contains extensive self-checking software and hardware that continuously monitors operation. Any sensor or device
parameter that is out of spec is identified and reported
General
Operating Ambient
Environment
Materials of Construction
Power
Random Vibration
Characteristics
Electromagnetic Compatibility
Operates within specification in fields from 80 to 1,000MHz with field strengths to 30V/m. Meets EN 50082-1 General
Electromagnetic
Self-contained power
1: C Cell, (standard)
Standard Accutech field units include a single C-Cell lithium battery that offers 3+ years of maintenance-free service
(up to 10 years depending on data rates and battery options).
Disclaimer: Schneider Electric reserves the right to change product specifications. For more information visit www.schneider-electric.com.
Model
TBUATM
Code
Type
Wireless Turbine Meter Totaliser Field Unit
Code
J
Q
Code
P
Code
N
Code
869MHz (Europe)
00
01
10
10ft. (3.05m) cable with N-Male connector for remote antenna configurations
25
25ft. (7.62m) cable with N-Male connector for remote antenna configurations
Code
Integral (direct connect of Magnetic pick-up below, or customer supplied - no Junction Box)
Code
00
None (Intrinsic Safety rating Option J is available for Customer Supplied pick-ups meeting specifications)
01
Magnetic pick-up, Electronic Data Devices model 4.303 - for turbine meters with an I.D. >= 7/8
02
Magnetic pick-up, Electronic Data Devices model 4.5050 - for turbine meters with an I.D. <= 3/4
Code
None (customer-supplied)
Code
Stainless Steel Union, for Integral Sensor Mounting only (Shipped Assembled)
NEMA 4X - Stainless Steel Rear Entry, for Remote Sensor Mounting only
3.82
(97.0mm)
3.82
(97.0mm)
4.68
(119.0mm)
10.04
(255.1mm)
Approx.
NEXT
Accutech
ENTER
1 NPT (Female)
3.82
(97.0mm)
4.68
(119.0mm)
NEXT
Accutech
ENTER
1 NPT (Female)
23,03
(584.8mm)
| www.schneider-electric.com
11.08
(281.6mm)
Approx.