Article 1 Relay No. 50 (Relay Device Number 50) means nothing relays.
Answer 1: Undervoltage Relay
Answer 2: Instantaneous Overcurrent Relay.
Answer 3: AC Time Overcurrent Relay.
Answer 4: Frequency Relay
Article: 2 Which is not a way to detect faults (Faults) in the electrical system of the relay.
Answer 1: level measurement (Level Detection).
Answer 2: Comparison of different streams (Differential Current Comparison).
Answer 3: Comparison of phase (Phase Angle Comparison).
Answer 4: Compare the speed of the flow of current when a short circuit occurs.
Article: 3 Standard IEC 60617 (IEC Relay Symbols) of the relay shown. Means any relay
Article: 15 Relay Number 51 standard ANSI Standard refers to any type of relay.
Answer 1: Ground Protective Relay.
Answer 2: AC Time Overcurrent Relay.
Answer 3: Reverse-Phase or Phase-Balance Current Relay.
Answer 4: Instantaneous Overcurrent Relay.
Article: 16 Relay Number 21 standard ANSI Standard refers to any type of relay.
Answer 1: Ground Protective Relay.
Answer 2: AC Time Overcurrent Relay.
Answer 3: Distance Relay
Answer 4: Reverse-Phase or Phase-Balance Current Relay.
Article: 17 Relay Number 67 standard ANSI Standard refers to any type of relay.
Answer 1: AC Time Overcurrent Relay.
Answer 2: Reverse-Phase or Phase-Balance Current Relay.
Answer 3: Ground Protective Relay.
Answer 4: AC Directional Overcurrent Relay.
Article: 18 Relay Number 49 standard ANSI Standard refers to any type of relay.
Answer 1: Thermal Relay
Answer 2: Under Voltage Relay.
Answer 4: Ground Protective Relay.
Article: 19 What is the principle of detecting a fault (Detection of Fault) Relay.
Answer 1: Relay operation when the electrical system is higher than the level set.
Answer 2: Relay operation when the electrical system is well below the level set.
Answer 3: Relay working on the second volume of electricity is very different than the setting.
Answer 4: All of the above.
Article: 20 High Impedance Relay is a relay of any kind.
Article: 40 Within the structure of the relay Microprocessor or Digital Relays used in modern times to
include Anti - Alias Filter to do anything.
Answer 1: Use a noise filter before entering the relay.
Answer 2: Use a separate circuit and to reduce the signs before the relay.
Answer 3: Use the power electronic circuits within the relay.
Answer 4: Use the signal within the relay.
Article: 41 Relay Number 21N standard ANSI Standard means a relay of any kind.
Answer 1: Ground Fault Over Voltage Relay.
Answer 2: Ground Fault Under Voltage Relay.
Answer 3: Ground Fault Distance Relay.
Answer 4: Ground Fault High Impedance Relay.
Article: 42 Over-Voltage Relay will resume Contact type "a" to each other when.
Answer 1: voltage reaches a preset value.
Answer 2: High voltage exceeds a preset value.
Answer 3: voltage is lower than the set value.
Answer 4: pressure dropping to zero.
Article: 43 The main function of the Relays
Answer 1: a cutting device directly on the circuit Faults.
Answer 2: The Circuit Breaker is a circuit breaker when the Faults.
Answer 3: a device to detect the position of the Faults in the power system.
Answer 4: a device fault occurred in the electrical system.
Article: 44 The device uses data analysis and signal processing within the Digital Relays.
Answer 1: Memory Unit
Answer 2: Microprocessor Unit
Answer 3: Analog to Digital Converter.
Answer 4: Sample and Hold Device.
Article: 50 Device ID Number 52-a standard ANSI Standard refers to any type of device.
Answer 1: Auxiliary Contact normally open (Normally Open).
Answer 2: Auxiliary Contact normally closed (Normally Close).
Answer 3: Auxiliary Relay Normally Open (Normally Open).
Answer 4: Auxiliary Relay is normally closed (Normally Close).
Article: 51 Device ID No. 52-b standard ANSI Standard refers to any type of device.
Answer 1: Auxiliary Contact normally open (Normally Open).
Answer 2: Auxiliary Contact normally closed (Normally Close).
Answer 3: Auxiliary Relay Normally Open (Normally Open).
Answer 4: Auxiliary Relay is normally closed (Normally Close).
Article: 52 Under-Voltage Relay is activated when the pressure is lower than the value set by the.
Answer 1: The relay Contact type "a" to each other.
Answer 2: The relay Contact type "b" to each other.
Answer 3: Relay to break Contact type "a" from each other.
Answer 4: Relay to break Contact type "b" from each other.
Article: 53 It does not differentiate between. Instantaneous Relay with Inverse Time Relay
Answer 1: Instantaneous Relay structure Hinged Armature but the Inverse Time Relay is Induction Type.
Answer 2: Instantaneous Relay Armature Attractive structure, but of an Inverse Time Relay Induction
Disc.
Answer 3: Instantaneous Relay is active once the current flowing through the Coil Fault exceeds the
value set, but Inverse Time Relay will be proportional to the amount of running time.
Current
Answer 4: Instantaneous Relay create easier Inverse Time Relay.
Article: 54 The following text Which is correct A. Solid State Relay is a relay that has no moving parts B.
Solid State Relay is a relay that does not require external power from C.
Microprocessor Relay is a relay that can perform many functions in one. D.Microprocessor Relay is a
relay circuit within a complex structure.
Article: 62 Standard IEC 60617 (IEC Relay Symbols) of the relay shown. Means any relay
Article: 89 Which is not a major factor in determining the time Grading Margin for grading work time
overcurrent relays.
Answer 1: Time to break the cycle of Circuit Breaker.
Answer 2: excessive running time (Overshoot Time) of the relay.
Answer 3: The time allowance (Allowance) for errors.
Answer 4: fixed period of short circuit.
Article: 90 The definition of "overcurrent (Overcurrent)" to protect the power system have a look what.
Answer 1: There are two ways to Short Circuits Inrush Current.
Answer 2: There are two ways to Short Circuits Interrupting Current.
Answer 3: There are two ways to Short Circuits Over Load.
Answer 4: There are three types of Short Circuits, Over Load and Transient.
Article: 91 The symbol of "Instantaneous Overcurrent Relay" by IEC (IEC Symbols) is any.
Article: 92 The symbol of "Inverse Time Overcurrent Relay" by IEC (IEC Symbols) is any.
Article: 93 The symbol of "Inverse Time Earth Fault Overcurrent Relay" by IEC (IEC Symbols) is any.
`
Article: 94 The symbol of "Phase-Directional Overcurrent Relay" by the IEC (IEC Symbols) is any.
Article: 95 The symbol of the "Ground-Directional Overcurrent Relay" by the IEC (IEC Symbols) is any.
Article: 96 Electrical short circuit current of a maximum of 8,000 A relay overcurrent protection. By
commuting flows through the transformer (CT) with a flow rate of 500/5 A test to calculate.
For the Plug Setting Multiplier (PSM) will be how much. When adjusting the flow at 150%.
Answer 1: 6.0
Answer 2: 8.76
Answer 3: 9.56
Answer 4: 10.67
Article: 97 The working conditions of Directional Overcurrent Relay is any.
Answer 1: When the relay flow visibility. Greater than or equal to the current setting. The relay run
Answer 2: When the relay flow visibility. Greater than or equal to the current setting. The right direction
The relay run
Answer 3: When the relay flow visibility. Greater than or equal to the current setting. And the opposite
direction The relay run
Answer 4: When the relay flow visibility. Less than or equal to the current setting. The right direction
The relay run
Article: 98 Phase Directional Overcurrent Relay and Ground Directional Overcurrent Relay compliant
IEEE C37.2 (ANSI Device Numbers) means any number of relays.
order
Answer 1: 67 and 67N.
Answer 2: 51 and 51N.
Answer 3: 50 and 50N.
Answer 4: 32 and 32N.
Article: 99 Phase Directional Overcurrent Relay Electromechanical Form Able to use any of them.
Answer 1: 30 degree Connection.
Answer 1: 5 A
Answer 2: 4 A
Answer 3: 3 A
Answer 4: 2.5 A
Article: 105 Overcurrent Relay through the current transformer ratio (CT) has a Current Ratio 1000/1 A
is set to run at 125%, the start of the Relay is how much.
Answer 1: 2.0 A
Answer 2: 1.5 A
Answer 3: 1.25 A
Answer 4: 1.0 A
Article: 106 Overcurrent Relay through the current transformer ratio (CT) has a Current Ratio 1000/5 A
is set to run at 100% if the current size of 10,000 A Fault Find the PSM would be.
how much
Answer 1: PSM = 5.
Answer 2: PSM = 10.
Answer 3: PSM = 15.
Answer 4: PSM = 20.
Article: 107 In a three-phase 3-wire power system protection with Earth Fault Protection "Residual
Connected" will be used to carry current transformer (CT) How many characters.
Answer 1: using CT alone.
Answer 2: The use of CT 2.
Answer 3: CT use all three options.
Answer 4: CT use all four options.
Article: 108 Protection Earth Fault Protection of three-phase generator is grounded with Ground Return
must carry current transformer (CT) How many characters.
Answer 1: All four of the CT.
Answer 2: CT use all three options.
Answer 4: The current signal, which has a window of CT looped through the three-phase wiring is
Polarizing Signal.
Article: 142 Radial distribution model shown below. The relays are both working Curve Standard Inverse
(SI) [IEC 60255] When Discrimination. The relay Bus A And using a Bus B Grading Margin = 0.35 seconds
and adjust the settings as indicated. To calculate the time to work on the Fault relay at Bus B Fig.