Liebert Precision Cooling
Liebert Precision Cooling
Liebert Precision Cooling
And if you dont get rid of the heat, you are going to have problems.
The first step in taking control of this situation is to understand the threats
to your system reliability and exactly what you can do about them.
Mission-Critical Cooling Provides Because Every Facility Is Unique, Todays systems offer a choice
Protection Under All Conditions Mission-Critical Systems Are of compressor types, micro-
Yes, computers have changed but Designed to Meet The Cooling processor controls and other
the threats to their operation are Needs Of Any Critical Space optional features designed to
as real as ever. An air conditioning A mission-critical cooling system reduce power consumption
system that maintains the can be engineered to match just and maximize energy savings.
temperature and humidity at the about any type or size of facility.
proper levels in your critical facility There are downflow systems for Mission-Critical Systems
is an absolute necessity for the raised floor facilities and upflow Are Designed To Operate
viability of your business. units where the floors are not Year-Round
raised. Supplemental systems Because most critical computing
Mission-Critical Systems Keep can be used where equipment and communications facilities
Moisture And Air Cleanliness is tightly packed in racks. function on a 24 x 7 basis
Right Where They Need To Be Compact models are ideal for so must the environmental
Ordinary building air conditioning small or remote facilities. equipment that is protecting it.
and heating systems are designed to Mission-critical cooling is designed
keep people comfortable. Computers Mission-Critical Cooling Systems to run around-the-clock, no
and other sensitive electronics Are Engineered To Get The Most matter what the outside
require a system that provides From Every Energy Dollar weather conditions.
humidity control to meet equipment Energy efficiency is no longer just an
specifications and air filtration option for users of air conditioning.
designed to keep airborne particles
from causing problems.
2
INFRASTRUCTURE
ECO AVAILABILITY FLEX CAPACITY HIGH DENSITY
MANAGEMENT
Balancing high levels Adapting to IT changes for Delivering architectures
Improving performance
of availability and continuous optimization from 1060 kW/Rack to
of the IT infrastructure
efficiency and design flexibility minimize space and cost
and environment
True data center efficiency is not limited to lower energy usage it Efficiency Without Compromise provides a path to optimize data center
must encompass efficiency across all aspects of design, operation infrastructure around design, operating and management efficiencies
and management. Focusing purely on energy efficiency can result in while maintaining or improving availability. This is achieved through
compromising the efficiency or reliability of other critical IT operations. the proper selection and utilization of cooling, power and monitoring
Emerson Network Power delivers Efficiency Without Compromise by technologies, supported by key services and local expertise.
identifying and improving on areas of opportunity to create both energy
savings and improved operation and workflow.
3
You Need To Start With The Right Kind Of Cooling
Some operations may be tempted to utilize standard comfort cooling systems to save money or to avoid using additional floorspace
within their facility. But while these moves may provide some benefits in the short term they must be balanced against the
cost of potential downtime and equipment damage caused by serious overheating, as well as the risk of financial loss.
Comfort Air
4
Mission-Critical Air Typical Comfort Air
What Makes A Mission-Critical Air Required Attributes Conditioning Systems Conditioning Systems
Conditioning System So Different? High sensible heat ratio Computer environments People produce an equal
to provide high cooling produce high heat/no amount of heat and humidity
There are several key areas that differentiate mission-critical capacity/minimum humidity
dehumidification
cooling from ordinary comfort air conditioning systems. Design
Considerations High-efficiency Typical MERV rating of 5 Minimum MERV rating of 8
Each of these performance criteria has a major impact on the For Any air filtration
Computer Room
Environment
proper environmental protection of your critical facility. Humidity control Integral with control system Typically an add-on system
with separate controls
Temperature And Humidity Control Year-round operation Positive operation with Typically used May to October
Mission-Critical Systems are specifically designed to outside temperatures as
low as -30 F
handle the heat loads generated by electronic equipment.
They utilize fast-response microprocessor control systems High density loads 1 per minute; 2 per minute 3-4 per hour
require more room at 200w/sq. ft.
to adjust quickly to changing conditions within the Additional air changes
room, while providing you with complete supervision of Design
Considerations More tons of cooling One ton of cooling for every One ton of cooling for every
temperature and humidity at all times. Liebert lets you Required For per square foot 10- 60 square feet of space 200-400 square feet of space
High Density
choose from several humidification methods including Environments Control staging Fast-acting, multiple Slow response systems,
integral infrared and steam generation units. cooling stages maintain typically only on/off control
tight control
Air Flow Management
Providing the proper volume of air to the specific location Full System Power Comparison - 100% Load
in a data center is as important as the temperature control. 100 900
Mission-Critical Air
Microprocessor control
High Volume
systems manage cooling,
Air distribution
heating, humidification,
(500-600 CFM
and dehumidification.
per-ton) manages
high density
heat loads
5
Knurr Racks
Labs & Testing Sensitive computers and equipment Low profile casters
used for diagnosing patients, analyzing data, allows 42u cabinet to roll
performing critical tests, and operating electronic tools through standard doorway
and lab instruments.
Production Smart factories backed by a complex
electronic network, from computer-controlled
machinery and processes to electronic sensors,
business systems and utility equipment.
6
Telecom Wireline / Wireless Spaces
Emergency Shelters
Mechanical Rooms
Computer Rooms
Network Closets
Data Centers
Production
Precision Computer Cooling
and Fluid-Cooling Systems
Liebert InteleCool 2 8
Liebert XD-Piping 12
Liebert Mini-Mate 2 14
Liebert DataMate 15
Liebert CRV 18
Liebert CW 20
Liebert DS 22
Liebert SmartAisle TM 25
Facility-Wide Surge
Suppression Products
DC Power Products
7
Liebert InteleCool 2
Painted steel or
aluminum cabinets
Heavy-duty double
width blower
High efficiency
R-407C scroll
compressor
Optional Economizer
with spring-return
actuator
Choice of compressor
on right or left side
of unit
Copper-tube,
aluminum fin coils
8
Liebert InteleCool 2 Product Features Include:
elf-contained design with all components enclosed in a painted
S
ith right hand or left hand compressor location, the space used
W
utside air options include economizer for cooling using outside air
O
and fresh air damper which allows a continuous amount of air to be
introduced through the unit.
Economizer Option
The Liebert InteleCool 2 can be equipped with an
economizer system that uses modulating dampers
to draw in filtered, outside ambient air for cooling
when the exterior temperature drops below a
pre-set level. These outside air temperature settings
are field adjustable. The economizer saves energy
and reduces component wear.
Controls
For the highest levels of reliability and
to minimize site downtime critical shelters
can be equipped with two Liebert InteleCool 2
units and an autochangeover system that
balances runtime and automatically switches
from one unit to another unit if required.
9
Liebert MCR, Liebert XDF, Liebert XDK
closets, computer rooms, and other Mobile design for quick deployment lets
you put a self-contained mini-computer
room right where you need it, today or
locations with a small number of racks. tomorrow.
These rack-based components must be Agency approved as a system pre-qualified
and ready for installation.
protected with the same level of cooling, ECM (Environmental Control Module)
computer-grade air conditioning load
power and physical security support matched to UPS.
10
Liebert XDF Liebert XDK-W
The air-cooled Liebert XDF extreme density Another innovative solution for protecting high
enclosure is a fully self-contained plug-and-play density applications is the Liebert XDK-W rack
($000)
$15,000
1.00
Can cool more than 30kW per rack.
0.80 15% Lower
0.60
Power Usage
Fan modules as your needs change
Pump (XD) The smaller chiller
0.50 Pump (CW)
Chiller plant and lower without the need for an HVAC
0.40
fan load result in
0.30 significant energy
technician.
0.20 32% Lower
savings. A 27%
0.10 27% Lower
energy savings is
0.00 very conservative.
CW CRAC CW CRAC Liebert XD Liebert XD
at 100% at 50% at 100% at 50%
Capacity Capacity Capacity Capacity
exchangers.
12
Liebert XDO
HOT AISLE
HOT AISLE
COLD AISLE
COLD AISLE
Liebert XD Piping is
pre-fabricated distribution
piping that is installed in
Liebert XDV anticipation of a growing
system. Liebert XD Cooling
modules are then added,
disconnected, or repositioned
as required and are quickly
HOT AISLE
HOT AISLE
COLD AISLE
COLD AISLE
The Liebert XD units work extremely well with the hot aisle/cold aisle design
of raised floor applications by efficiently drawing hot air out of equipment
racks and moving cool air into the cold aisle.
Water-Cooled Approach
In-Row Cooling The Most Energy The Heart Of The Liebert RackCooler
Thats Right In Line Efficient Cooling Water-based System
With Your Needs Available The Liebert XDR-W Rack
The Liebert XDP-W Coolant Cooler utilizes a cooling
The modular Liebert XDH Liebert XDR Rack Door Pumping Unit is the key to unit that is attached to the
Horizontal Row Cooler Cooling Module replaces the performance, efficiency back door of the enclosure.
is placed directly in line the back door of a server and space saving of the Fans in the module move air
with rack enclosures. enclosure, providing Liebert XDR-W RackCooler from the equipment in the
Air from the hot aisle is cooling without increasing and Liebert XDK-W water- rack, through a cooling coil
drawn in through the the rack footprint. The cooled rack enclosure. and expel it from the back of
rear of the unit, cooled, module uses the server
The unit houses the isolating the unit, chilled to the point
and then discharged fans within the protected
heat exchanger between the where the impact on the
through the front of the rack to provide airflow,
Liebert XDR-W/XDK-W circuit room is close to neutral. This
unit into the cold aisle. providing the most
The modular and adap- energy efficient design. fluid and building chilled makes the Liebert XDR-W an
tive design of the Liebert water, the control valve, ideal solution in applications
XDH allows it to be easily the dual redundant pumps where the hot aisle/cold aisle
added as the demand and the system controls. It arrangement is not practical.
for cooling increases. controls the fluid temperature The Liebert XDR-W can be
Available with Smart to always be above the actual configured to eliminate hot
Module integrated con- room dewpoint to avoid spots or uneven heat loads
trol board, for increased condensation. The Liebert within the room.
module control and XDP-W can be used with
monitoring. other brands of rack cooling
equipment.
13
Liebert Mini-Mate2
Available in 1, 1.5, 2, 3, 5 & 8 ton capacities, the Liebert Mini-Mate2s flexible design provides
air distribution for direct supply/return (1-3 tons) or ducted applications (1-8 tons). It includes
controls for temperature, humidification and dehumidification for year-round operation.
Models are available with air-cooled, water/glycol-cooled, freecooling Econ-O-Coil or chilled
water heat rejection systems.
Self-contained or split systems allows for 1-3 ton models with grille/plenum to fit
fitting systems with a variety of architectures. 2x4 ceiling grid for direct supply and
Reliable refrigeration components featuring return air distribution.
rotary or scroll compressors and copper Filter box, fan speed and/or blower
tube aluminum fin coils for high efficiency. options to handle ducted applications.
Easy-to-use menu-driven microprocessor Choice of hot water, stainless steel or
control. Optional room sensors available. stainless steel with SCR reheat.
Hot gas bypass for low load applications.
Building
Cooling
Tower
Free-Cooling Option When water temperature goes below
45F (7.2C), cooling switches over to
Free-Cooling operation. A separate
chilled water source can also be used
Free with Air-Cooled system.
Cooling
Coil
Water/
Glycol
Condenser
14
16
Liebert DataMate
Li eb ert Mi ni - Mate2
Ideal for applications where people and sensitive electronics must occupy the same
space, the Liebert DataMate provides 1.5, 2 or 3 tons of cooling capacity from a compact
unit that requires little or no floorspace. Its low profile permits floor mount or wall mount
installation, allowing more room for critical equipment.
Built with rugged components, the Liebert DataMate is designed to control temperature and
humidity around-the-clock for year-round operation. The Liebert DataMate can manage the
15
Liebert Challenger 3000
Designed to fit in the crowded confines of an equipment room or laboratory, the Liebert Challenger 3000
offers an extremely compact footprint for facilities where space is at a premium. This versatile unit is
available in single circuit, self-contained or split systems to fit a variety of site plans.
All of Liebert Challenger 3000s critical The Compact Liebert Challenger 3000
components are accessible from the front, Is A Perfect Match For Many Critical
so the unit can be installed in a corner or Applications:
Small data centers.
flush against other equipment.
Laboratories and medical imaging suites.
The Liebert Challenger 3000 provides Telecommunications switching facilities.
complete environmental control, including Industrial process control rooms.
temperature, humidity and air filtration.
A choice of humidification control includes
an infrared humidifier, to provide
instantaneous water vapor, or a steam
generating unit. Electric, SCR and hot
water reheat options are also offered.
Vibration-Isolated
Fan Deck
Corrosion-Resistant
Steel Frame
Stainless Steel
Finned-Tube Reheat
Infrared Humidifier
For Precise Humidity
Control
Digital Scroll
Compressor
16
Li eb ert C hal l eng er 3000
Liebert Challenger 3000 Product Liebert iCOM Optimized System Performance
Features include:
3 and 5 ton capacities.
Reliable refrigeration components featuring scroll
compressors, A-frame evaporator coils, all factory
pre-piped, wired, and tested in a rugged, easy-
access tubular-steel frame.
Designed for upflow or downflow floor mounting
in self-contained or split-systems.
A choice of air-cooled, water/glycol-cooled,
The standard Small Graphic Display offers a
GLYCOOL Econ-O-Coil or chilled water heat 128 x 64 dot matrix screen that simultaneously
17
Liebert CRV
18
Liebert CRV: Reliable, Flexible And Economical
Li eb ert C RV
Designed for hot-aisle/cold-aisle configuration, Liebert CRV Product Features
Include:
the Liebert CRV is available in 20 kW and 35 kW
rovides 24/7 precision environmental
P
air-cooled or water/glycol-cooled systems, or a 40 control: cooling, humidity control and
kW chilled-water system. air filtration.
Adjustable airflow baffles maximize
19
Liebert CW
Data centers
Telecommunications central switching offices
Industrial process control centers
Laboratories
Medical facilities
EC Plug Fans are available on all Liebert CW downflow models.
Shown in underfloor configuration.
20
Economical Chilled Water Systems
Li eb ert C W
By taking advantage of your existing central air conditioning
chiller, the Liebert CW provides thrifty, durable cooling and
humidity control around the clock, throughout the year.
The Liebert CW chilled water system offers rugged, yet
EC Plug Fans in underfloor configuration
affordable cooling and humidity control where a central (available on all Liebert CW downflow models)
water chiller is available as a year-round cooling source.
Economizer operation
For economical, free-cooling operation, Liebert CW is
compatible with the Liebert Air Economizer solution,
Premium efficiency centrifugal fans,
and also works with Chiller Plant Series Economizer
and optional Variable Speed Drive fan
applications. Economizers can reduce operating costs
motors, are available on all models
by up to 50%, based on regional ambient conditions.
21
Liebert DS
Fully cleanable
Paradenser tubes
are located for
convenient
maintenance
Liebert DS Upflow
22
A Choice Of Compressors Offers
Higher Efficiency, Adaptability
Li eb ert DS
And Reliable Operation
Only Liebert offers you a choice of energy efficient compressor systems
Liebert iCOM Control System
to suit your specific application and budget requirements.
The Liebert iCOM control system featured on
the Liebert DS brings high-level supervision to
100% 100%
88%
75% 76%
50%
38%
25%
Liebert PB Series
Through the wall indoor heat rejection unit for those
applications where outdoor heat rejection location is not
practical, like high-rise buildings or areas with restricted
access. Available with Lee-Temp head pressure control.
Liebert 2 fan Condenser
minimal noise level. This is accomplished as the result 70 Vacuum Standard Air Cooled
Condenser/Drycooler
60 Conversational speech
of the Liebert fan blade design combined with a cabinet Liebert Quiet-Line Air Cooled
50 Bird chirping Condenser/Drycooler
structure that minimizes air resistance. In applications
40 Quiet residential area
where noise restrictions are a concern and further sound 30 Whispered conversation at 6 feet
condensers and drycoolers offer levels as low as 57 dBA. 10 Threshold of good hearing
unit operating noise even further through the use of For very low noise applications, the Liebert Quiet-Line models achieve
lower speed motors and a larger coil surface. additional sound reduction with slow speed motors (570 rpm).
24
SmartAisle TM
The heart of the SmartAisle system is the unique Liebert iCOM control 89F
system that dynamically optimizes the operating parameters of your
Precision
IT Racks
IT Racks
Cooling
precision cooling environment.
54F 70F
SmartAisle is Ideally Suited For:
ot aisle/cold aisle applications.
H 54F
aised floor data centers with perimeter cooling.
R
on-raised floor data centers using row-based precision cooling systems
N Measurable Energy Efficiency
such as Liebert CRV or Liebert XD.
SmartAisle TM
etrofit to existing racks.
R Traditional Operation
85F
75F
Configure Smartaisle To Maximize Energy Efficiency And 94F
89F
System Availability:
Speed
Speed
Precision
L iebert iCOM control.
IT Racks
IT Racks
Cooling
Precision
IT Racks
IT Racks
Cooling
Fan
Temperature and airflow sensors. 80F
Fan
62F
90%
54F 70F
100%
Knurr DCM cabinets.
Plexiglass roof panel system/containment curtain. 62F
54F
Sealed entry doors.
Liebert Precision Cooling systems. SmartAisle With Integrated Containment:
Roof-mounted wiring module.
Liebert iCOM
SmartAisle is Designed To:
85F
Optimize Cooling System Efficiency.
94F 92F
Eliminate Hot/Cold Air Mixing.
97F
Fan Speed
IT Racks
Cooling
Fan Speed
Increase Capacity.
Precision
IT Racks
IT Racks
Cooling
62F 80F
67%90%
Precision
IT Racks
IT Racks
Cooling
62F
25
Environmental System Monitoring:
The Key To Continuous Operation
The reliability of your computing and communications Different People Need To Know
Different Things
systems will be a direct result of the reliability of the
environmental systems that help maintain their proper Liebert offers you more monitoring solutions than anyone
else because getting the right information about your
operation. This requires monitoring of these support
support equipment to the right people with the right
systems as assurance that vital functions will continue level of urgency is so important to system availability.
without interruption.
We do this by allowing you to receive and use information
What You Dont Know Can Hurt You from your Liebert equipments microprocessor controls
no matter where it is located or what communications
A small problem in a critical facility can quickly escalate
protocol, operating platform or building management
into a disaster knowing what is happening with your
system is being used. In-band, out-of-band and web-based
support equipment, so you can keep that protective
monitoring are all available. From enterprise monitoring
envelope at peak operating efficiency, is vital to system
systems to individual pieces of communications hardware,
reliability. Liebert offers full-scale monitoring and control
you will know the exact problem so that you can
of critical support systems by providing the ability to
implement the right solution.
gather operating information from each piece of
equipment and pull it together in one central location.
Control
Liebert
Nform Liebert SiteScan Web
Distributed Centralized
Liebert
MultiLink
Monitoring
26
Maximizing Your Investment Through Adaptive Monitoring
Liebert Nform
Liebert IntelliSlot Web
27
From Design To Final Assembly
Heres What Makes The Difference
Everything we do is focused towards youthe customer. The Liebert design and manufacturing philosophy covers every aspect
of the product from advanced engineeringto providing detailed equipment drawingsto manufacturing quality in our ISO
9000 certified production facilitiesto assuring on-time delivery. We want you, your consultants and your contractors to
depend on Liebert and our ability to always meet your needs from start to finish.
Whatever It Takes To Meet The Needs We also offer other resources and tools to help create
Of Our Customers the right product solution. Our Special Features
Liebert utilizes state-of-the-art tools, including Authorization capability allows cost-effective
advanced computer-aided design and simulation customization. Submittals and guide specs help you
tools, to constantly refine the design of our select the right system configuration. Comprehensive
products, including: literature and technical manuals make sure that you
have the most complete and up-to-date information on
Solid Edge a CAD/CAM system that utilizes 3D
the operation of your Liebert product.
technology to reduce design times and improve
product quality.
CFD software that is designed to calculate airflow,
heat transfer and contamination distribution by
simulating building heating and ventilation systems.
It employs the techniques of computational fluid
dynamics (CFD) in order to address the design and
optimization of these systems.
CFD software permits Liebert
engineers to optimize air flow
within each system. Side
views of Computational Fluid
Dynamics (CFD) by Fluent.
28
Its important to know that whether its
scheduled preventive maintenanceor
an emergency situation, service support
will be quickly and expertly handled.
There are many places where Liebert Full scale analysis and evaluation of After you purchase your Liebert
equipment is vital such as computer our air conditioning products during precision cooling system, there
rooms, telecommunications centers, all phases of development and will always be someone who can
high density Internet hosting sites, production is your assurance of the answer any questions or operational
colocation facilities and industrial most advanced performance and problems you may have.
control rooms. Our application highest quality. We are committed to providing
engineers are experienced in all of comprehensive service training
A Company-Wide
these situations and can make sure programs to all of our service
Commitment To Excellence
you always get a cooling solution engineers and technicians. Lieberts
Our employees take great pride in service capabilities, including
that is tailored to your exact needs.
the products they build. Liebert preventive maintenance programs,
To help maximize the performance
products are manufactured under can increase the availability of
and energy efficiency of the unit
the stringent manufacturing and your precision cooling equipment
selected, they also utilize tools
quality control processes of ISO by reducing downtime due to
such as Coolsim and 6-Sigma,
9000 certification, using the latest component failure. This is especially
simulation software packages for the
computer-controlled equipment. All valuable to companies who do not
improvement of airflow distribution
phases of production are carefully have a dedicated technician on-site
in data centers.
monitored and controlled. to troubleshoot equipment.
29
Precision Cooling Solutions To Keep You Up And Running
Emerson Network Power offers more ways to handle your Liebert precision cooling maintenance and emergency service require-
ments than any other source. Service and support specialists are located everywhere you need them to be.
The Best Coverage In The Business Additional Service Offerings That Make
Field service is provided by Liebert Services technicians augmented A Difference
with The Liebert Service Partner Network a nationwide network Liebert Services can also help to improve your data center perfor-
of locally-based service partners, with factory-trained technicians mance and energy efficiency.
that handle service support and maintenance of Liebert precision Enterprise remote monitoring.
cooling products. Warranty inspection at the time of start-up by Liebert iCOM controls networking/upgrading.
these technicians can ensure proper operation and tune the per- Thermal assessments and CFD modeling.
formance of the unit to the application. This can be instrumental in Energy efficiency assessments.
assuring a long unit life.
Remote Monitoring
The variety of service offerings includes warranty service, emer- Enhance your data center reliability and visibility with comprehensive
gency service, preventive maintenance and professional services. alarm management, diagnostics and response services that are tai-
We offer 24 x 7 x 365 emergency dispatch service through our lored to your specific needs. For both flexibility and reliability, we can
Customer Resolution Center. This facility provides immediate access monitor via the Web or through dial-up. By using network interface
to factory-trained technicians, located within your own area, who cards, we provide significantly more alarm types for diagnostics. And
are quickly dispatched to your location when service is required. our Customer Resolution Center is ready to respond as soon as an
Preventive maintenance solutions provide you with a choice of alarm occurs.
coverage options each designed to meet your specific support
requirements. These offerings are ideal for those who require the Our ability to poll your equipments operational data at regular
peak operating efficiency, reliability and uptime that only a compre- intervals provides unsurpassed predictive maintenance capabilities.
hensive maintenance program can deliver. Certified technicians analyze your data, identifying issues before they
become problems and maximizing availability.
We also offer a site management program that creates a custom-
ized service package for your operation by offering a single point of
contact for all your service needs. It gives you a proactive action plan
to provide operational support and guidance for your critical facility.
Full Service And Preventive Maintenance Programs For Precision Cooling Equipment
Service Guaranteed Emergency Preventative Prev. Maintenance Service
Program 4 hr Response Service Maintenance Schedules Description
Parts, Labor & Travel Preferred Service (8) PMs per year 7x24
Preferred 7 Days 7 Days Choose 2 or 4 or 8 Preventative
7 Days Preferred Service (4) PMs per year 7x24
PMs 7x24 24 Hours 24 Hours Maintenance visits per year
24 Hours Preferred Service (2) PMs per year 7x24
Parts, Labor & Travel Essential Service (8) PMs per year 8x5
Essential 7 Days M through F Choose 2 or 4 or 8 Preventative
7 Days Essential Service (4) PMs per year 8x5
PMs 8x5 24 Hours 8:00 am - 5:00 pm Maintenance visits per year
24 Hours Essential Service (2) PMs per year 8x5
Maintenance with belts & filters (8) PMs per year 7x24
Maintenance with belts & filters (6) PMs per year 7x24
PM Only 7 Days 7 Days Choose 2 or 4 or 8 Preventative Maintenance with belts & filters (2) PMs per year 7x24
Billable
7x24 24 Hours 24 Hours Maintenance visits per year Maintenance only (8) PMs per year 7x24
Maintenance only (4) PMs per year 7x24
Maintenance only (2) PMs per year 7x24
Maintenance with belts & filters (8) PMs per year 8x5
Maintenance with belts & filters (6) PMs per year 8x5
PM Only 7 Days M through F Choose 2 or 4 or 8 Preventative Maintenance with belts & filters (2) PMs per year 8x5
Billable
8x5 24 Hours 8:00 am - 5:00 pm Maintenance visits per year Maintenance only (8) PMs per year 8x5
Maintenance only (4) PMs per year 8x5
Maintenance only (2) PMs per year 8x5
Labor Only
Basic PMs 7 Days M through F Choose 2 or 4 Preventative Basic Service (4) PMs w/ B&F per year 8x5
7 Days
8x5 24 Hours 8:00 am - 5:00 pm Maintenance visits per year Basice Service (2) PMs w/B&F per year 8x5
24 Hours
Labor Only
Basic PMs 7 Days 7 Days Choose 2 or 4 Preventative Basic Service (4) PMs w/ B&F per year 8x5
7 Days
7x24 24 Hours 24 Hours Maintenance visits per year Basice Service (2) PMs w/B&F per year 8x5
24 Hours
30
Liebert: The World Leader In Mission-Critical
Power And Cooling Technologies
You Know About Our Complete Line Liebert Integrated Racks And Cabinets Protection
Of Environmental Control Systems Wherever Its Needed
From high-capacity mission-critical cooling systems to compact Rack-based equipment has formed the foundation of todays IT
and above-ceiling units to our targeted cooling products network. To house and protect these systems, Liebert offers a
designed for the demanding requirements of high density complete line of rack, cabinets and integrated protection enclosures
electronic installations there is a Liebert solution designed to for rack-mounted components. From open racks employed in large
cool and protect your critical computing and communications data centers to self-contained, integrated enclosures with cooling
equipment. We make the industrys widest range of mission- and power protection used in remote locations, there is a Liebert
critical environmental control, including air conditioners, fluid rack solution for every application.
chillers and heat rejection systems from 1.0 to more than 60
tons, in a variety of configurations and cooling technologies. Monitoring Solutions From Liebert The Smart
Decision To Make
Liebert Offers A Full Range
Liebert is the only source that supplies the protection infrastructure
Of Power Protection Solutions
and all the tools you need to know how it is operating every minute
A steady flow of power, and the means to get it to each piece of every day.
of equipment in a critical facility, is a key to systems reliability.
From one-on-one supervision of a single piece of equipment to
The proper functioning of these systems depends on the qual-
full-scale monitoring and control of several far-flung facilities, no
ity of power and the ability to ride through outages of any dura-
one knows more about what it takes to keep you in the know
tion. Only Liebert offers the breadth of power supply products
about your critical systems than Liebert.
to meet any of these needs.
31
Ensuring The High Availability Of
Mission-Critical Data And Applications.
are supported globally by local Emerson Network Power service technicians. Liebert Emerson Network Power
European Headquarters
AC power, precision cooling and monitoring products and services from Emerson Via Leonardo Da Vinci 8
Network Power deliver Efficiency Without Compromise by helping customers Zona Industriale Tognana
35028 Piove Di Sacco (PD)
optimize their data center infrastructure to reduce costs and deliver high availability. Italy