Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

How Peristaltic Pump Works

Download as pdf or txt
Download as pdf or txt
You are on page 1of 12

The UKs leading pump specialist since 1971

michael smith engineers ltd for difficult liquid handling applications

How a
Peristaltic
Pump works

Freephone 0800 3167891 info@michael-smith-engineers.co.uk www.michael-smith-engineers.co.uk


The UKs leading pump specialist since 1971
michael smith engineers ltd for difficult liquid handling applications

Peristaltic Principle
The tubing is fixed between the tube-bed and the rotor
at each roller location the tubing is squeezed
position A, B and C

The rollers on the revolving rotor move across the


tubing
the tubing is continuously squeezed by the rollers which
push the liquid in the direction of the revolving rotor

The tubing behind the rollers recovers its shape,


creates a vacuum and draws liquid in behind it.

Freephone 0800 3167891 info@michael-smith-engineers.co.uk www.michael-smith-engineers.co.uk


The UKs leading pump specialist since 1971
michael smith engineers ltd for difficult liquid handling applications

Peristaltic Principle
A pillow of liquid is formed between the
rollers
the pillow is the pump chamber and
determines the volume per roller step and,
hence, the flow rate

the pillow volume not only depends on the


inner diameter (i.d.) of the tubing, but also
on the tubing properties, the drive and
pump-head specifications as well as the
liquid and the physical application
conditions

Freephone 0800 3167891 info@michael-smith-engineers.co.uk www.michael-smith-engineers.co.uk


The UKs leading pump specialist since 1971
michael smith engineers ltd for difficult liquid handling applications

Roller-step volume
The pillow volume determines the roller-step
volume which depends on:
Pump system Tubing
number of rollers inner diameter
pump-head design wall thickness
- e.g. spring-loaded tube-bed formulation
occlusion setting age of tubing
rotation speed

Liquid Application conditions


type of liquid suction lift / vacuum
temperature differential pressure
viscosity

Freephone 0800 3167891 info@michael-smith-engineers.co.uk www.michael-smith-engineers.co.uk


The UKs leading pump specialist since 1971
michael smith engineers ltd for difficult liquid handling applications

Flow rate
The flow rate is calculated as follows:
Volume per roller step (pillow volume)
x Number of rollers
= Volume per revolution

Volume per revolution


x Rotation speed per minute
= Flow rate per minute

Freephone 0800 3167891 info@michael-smith-engineers.co.uk www.michael-smith-engineers.co.uk


The UKs leading pump specialist since 1971
michael smith engineers ltd for difficult liquid handling applications

Advantages
no contact of the liquid with mechanical parts

tube is only part to wear

service and maintenance costs are minimal

easy to clean and sanitize

multi-channel systems available

Ismatec pumps available up to 24 channels

insensitive to dry-running

Freephone 0800 3167891 info@michael-smith-engineers.co.uk www.michael-smith-engineers.co.uk


The UKs leading pump specialist since 1971
michael smith engineers ltd for difficult liquid handling applications

Advantages
self-priming

excellent suction height


use tubing with small i.d., thick wall and stiff material

no siphoning effect when pump is stopped

immune to many chemicals


depends on the tubing material

suspensions and sludge can be pumped


with a solid content of up to 60%

Freephone 0800 3167891 info@michael-smith-engineers.co.uk www.michael-smith-engineers.co.uk


The UKs leading pump specialist since 1971
michael smith engineers ltd for difficult liquid handling applications

Advantages
virtually immune to abrasive media

liquids of high viscosity can be delivered

gentle delivery due to very low shearing forces


ideal for delicate suspensions
e.g. blood cells or bio-technological media are not damaged

some tubing material can be autoclaved

very high repeatability - suitable for auto-analyzers


pumps system must be calibrated

Freephone 0800 3167891 info@michael-smith-engineers.co.uk www.michael-smith-engineers.co.uk


The UKs leading pump specialist since 1971
michael smith engineers ltd for difficult liquid handling applications

Limitations
chemical inertness
depends on the tubing material

slight pulsation is inevitable

tubing requires recalibrating and changing


due to wear

at certain intervals depending on the application

very important for accurate and repeatable pumping

more frequently in comparison to gear and piston pumps

tubing may leak after extensive use

Freephone 0800 3167891 info@michael-smith-engineers.co.uk www.michael-smith-engineers.co.uk


The UKs leading pump specialist since 1971
michael smith engineers ltd for difficult liquid handling applications

Limitations
depending on the pump-head system the flow
rate is sensitive to varying differential pressure
conditions (all spring-loaded tube-beds!)

accuracy and repeatability of the flow rate also


depend on the tubing age and material used

max. differential pressure is lower in comparison


to gear and piston pumps
depends very much on tubing material and inner diameter
in relation to wall thickness

Freephone 0800 3167891 info@michael-smith-engineers.co.uk www.michael-smith-engineers.co.uk


The UKs leading pump specialist since 1971
michael smith engineers ltd for difficult liquid handling applications

Tubing size
The tubing is the pump chamber of the peristaltic
pump and, hence, one of the most important parts !
The following tubing specifications have particular
effects on the pumping process:
inner diameter (ID)
wall thickness (WT)
material (formulation)

Different combinations of these parameters change the


pumping behavior and consequently lead to different
results.

Freephone 0800 3167891 info@michael-smith-engineers.co.uk www.michael-smith-engineers.co.uk


The UKs leading pump specialist since 1971
michael smith engineers ltd for difficult liquid handling applications

Tubing Life
Life expectancy of the tubing depends on the
following features:
tubing material
drive speed
number of rollers
operating temperature
pressure conditions
liquid used
chemical composition, particles, etc
tube-bed and roller design

Ismatec catalogue provides overview of approximate


tubing life

Freephone 0800 3167891 info@michael-smith-engineers.co.uk www.michael-smith-engineers.co.uk

You might also like