STORM SEWER DESIGN (Metric Units)

This spreadsheet accompli shes a storm sewer design usi ng the rati onal method Enter the data in the grey shaded areas onl y.

Project Name: S.R.: Designed By:


Project Number: Date:

Location Discharge m = 176 n = 0.539 Drain Design Drain Profile


Remarks
Drai n Located From Sta. To Sta. Source of Drainage Manning Runoff CA Sum Tc to Total Tc to Rainfall Runoff Contri b. Total P ipe Pipe Fl ow Vel oci ty Pipe Capacity Pipe Elev. Upstr. Downstr. Upstr. Downstr.
On Drainage Area A (ha) roughn. Coeff. (ha) CA col 2 Sta* Col3 Sta ** Intensi ty (m3/ s) I nlfow Flow Dia. Slope (m/ s) (m3 /s) Length*** Change Ground Ground Invert E lev. Invert El ev.
coeff n C (ha) (mi n.) (min. ) (mm /hr) (m3 /s) (m3 /s) (mm) (m/m ) (m) El ev. Elev.

1 2 3 4 5 5a 6 7 8 8a 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
100 150 a 0.046 0.012 0.9 0.041 0.0414 5 5 73.921 0.008501 0.0085 300 0.008 1.3256 design is completed 40 0.31

* time of concentration of the flow to the inlet


* * assu ming tha t the p ipe i s flo win g slightly les s tha n half full up to c om plete ly full
* ** th e pip e's le ngth is the hor izontal projection of th e pi pe, in feet, fro m ce nters of app urtena nces