Manual Del Medidor de Campo
Manual Del Medidor de Campo
Manual Del Medidor de Campo
TM-192/TM-192D
HB2TM1920000
Table of Contents
T1 Introduction ............................................................................1
2 Application..............................................................................1
3 Features..................................................................................2
4 Identifying Parts.....................................................................3
5 Measurement Procedures ...................................................4
6 Clock setup ..............................................................................6
7 Auto power off setup ...............................................................7
8 Continuity data logging setup..............................................8
9 Clear data logger memory .......................................................9
10 Erase all data logger memory ................................................10
11 Single data memory ...............................................................11
12 Viewing logged reading control key......................................11
13 Specifications.........................................................................12
14 Battery replacement ...............................................................13
15 External DC Power .............................................................13
16 Safety Precaution ...................................................................14
17 Software installation (192D) ..............................................14
18 Note........................................................................................14
TM-192/D
1 Introduction
Safety precautions should be taken against electric appliances
in places including medical institutions, schools and residential
districts, where people usually stay for a long time, to prevent
patients, babies and senior citizens from exposure to high
electromagnetic waves.
An electromagnetic wave simply means the wave motion of the
electromagnetic field (EMF).
The change in electric fields produces magnetic fields, and the
change in magnetic fields can also generate electric fields. The
fluctuation of correlation between each other is known as
electromagnetic waves", which is a form of energy similar to
light and heat that can be transmitted either by radiation in the
air or by an electric conductor.
It is suggested that rearrangements should be made in families
and work locations where electromagnetic fields are detected
the strongest in order to avoid prolonged exposure to excessive
electromagnetic fields.
2 Application
z This meter is applied to measuring electromagnetic fields
of extremely low frequency (ELF) of 30 to 2000Hz.
z It is capable of measuring the electromagnetic field
radiation intensity that is produced from electric
transmission equipment, power line, microwave oven, air
conditioner, refrigerator, computer monitor, video/audio
device and so forth.
z The magnetic field unit is Tesla (T), Gauss (G),
milli-Gauss (mG) or micro-Tesla (T).
z 1 T10,000 G z 1 G1,000 mG
z 1T10 mG
EN-1
3 Features
z Uses three internal orthogonal sensors to test a wide
range of ELF magnetic fields, independent of
measurement angle .
z The tester is designed to provide user a quick, reliable
and easy way to measure magnetic field radiation levels
around power lines, home appliances and industrial
devices.
z The tester is a cost-effective hand-held instrument that
was designed and calibrated to measure magnetic field
radiation at different bandwidths from 30HZ to 2000HZ.
z Display micro Tesla(u T) or milli Gauss(m G) units.
z Data hold (HOLD)maximum Hold(MAX)and minimum
Hold(MIN)function.
z Auto range or manual range select mode.
z Datalogging capacity with Memory Size500 data sets
or 9999 data sets(192D).
z USB PC interface (192D).
z Time and calendar function.
z Low battery indication .
z Over load display OL.
z Auto power OFF function .
4 Identifying Parts 1. LCD display.
2. Power key.
3. maximum Hold and
minimum Hold key.
4. Data Hold key.
5. Record dada and Setup
function left key.
6. Range and Setup
function up key.
7. Reading and Setup
function right key.
8. Setup function key.
9. Units and Setup function
down key.
10. Enter key.
11. Calibrate point for Triple
axis.
12. External power DC 9V.
13. USB interface
(TM-192D).
14. Tripod mounting screw.
15. Battery cover.
5 Measurement Procedures
z Press key turn on the meter, press key again to
(T) unit.
measurement again.
(2.SET).
time.
record. .
record.
WARNING
If the symbol appears on the LCD, please
replace the battery immediately
15 External DC Power
z External AC to DC adapter: Voltage 9VDC(8~14VDCMax)
z Supply current300mADC
z Socketpin Positive, Ground Casing External
Diameter 6.3mm internal Diameter 2.0 mm
16 Safety Precaution
z For cleaning the instrument use a soft dry cloth. Never
use a wet cloth, solvents or water, etc.
z Operation Altitude: Up to 2000M.
z Operating Environment: Indoors use. This instrument has
been designed for being used in an environment of
pollution degree 2.
18 Note