Transformers
Transformers
Transformers
POWER QUALITY
Transformers
& shunts
Measurement
and Instrumentation
Transformers and shunts
Overview of ranges p. 102
Selection guide p. 104
Info & advice p. 110
Standard industrial transformers p. 112
TCR TCRO TC CLIP ranges
Shunts p. 144
76-2 77-2 SHMI SHEL SHMO ranges
101
Overview of product ranges
Standard industrial transformers
> Measurement and instrumentation Current transformers (CTs) & shunts
TCR TCR
Wound primary Cable/busbar primary
> page 113 > page 114
JVO JVP
Cable/busbar primary Busbar primary
> page 126 > page 127
102
ENERGY PERFORMANCE
Transformers for price metering
POWER QUALITY
Single-phase, single-rating Single-phase, multi-rating
JVP 1045B JVO 40-100 JVO 40-100S JVO 90-160S JVS 1145S
> page 134 > page 135 > page 136 > page 137 > page 138
Transformers
& shunts
Three-phase, single-rating Three-phase, multi-rating
TRI 500 TRI 700
> page 139 > page 140
shunts
Class 0.5 Class 1
76/2 77/2 range SHMI range SHEL range
> page 145 > page 147 > page 149
SHMO range
DIN rail mounting
> page 150
103
Choosing your standard industrial
Choosing your adaptable industrial current transformer: page 112
Choosing your transformer for energy metering: page 114
> Measurement and instrumentation Current transformers (CTs)
TCR TCR
Wound primary Cable/busbar primary
TCR 10 TCR 11 TCR 15 TCR 21 TCR 31 TCR 41 TCR 51 TCR 61 TCR 71 TCR 75
104
ENERGY PERFORMANCE
current transformer
POWER QUALITY
TCR TCRO TC CLIP
Busbar primary Split core Split core
Transformers
& shunts
TCR 80 TCR 90 TCR 100 TCRO 2030 TCRO 5080 TCRO 8080 TCRO 80120 TCRO 80160 TCC 241 TCC 242 TCC 364 TCC 366
24 24 36 36
100 x 20 100 x 30 1025 x 60 20 x 30 50 x 80 80 x 80 80 x 120 80 x 160
105
Choosing your adaptable industrial
Choosing your standard industrial current transformer: page 110
Choosing your transformer for energy metering: page 114
> Measurement and instrumentation Current transformers (CTs)
JVR JVO
Wound primary Cable primary
JVR 64 JVR 75 JVR 86 JVO 12-46 JVO 18-51 JVO 21-64 JVO 21-75 JVO 32-75 JVO 36-75 J3R 80 B
Primary 5A
10 A
15 A
20 A
25 A
30 A
40 A
50 A
60 A
75 A
100 A
125 A
150 A
200 A
250 A
300 A
400 A
500 A
600 A
750 A
800 A
1000 A
1200 A
1250 A
1500 A
2000 A
2500 A
3000 A
Strengths Primary connection via threaded A wide choice of primaries.
rod for more compact size.
106
ENERGY PERFORMANCE
current transformer
POWER QUALITY
JVO JVP
Cable/busbar primary Busbar primary
Transformers
& shunts
JVO 25 CR JVO 32 CR JVP 624 JVP 1025 JVP 1045
JVO version for cable or busbar primary. A wide choice of busbars from 60 to 100 mm.
107
Choosing your current transformer for
Choosing your standard industrial current transformer: page 104
Choosing your adaptable industrial current transformer: page 106
> Measurement and instrumentation Current transformers (CTs)
JVS JVS
Cable/busbar primary Busbar primary
> page 130 > page 132
JVS 25B JVS 26B JVS 30B JVS 38B JVS 39B JVS 40 JVS 50 JVS 60
108
ENERGY PERFORMANCE
energy and price metering
POWER QUALITY
Single-phase Single-phase multi-rating Three-phase Three-phase multi-rating
single-rating single-rating
> pages 134-135 > pages 136-137-138 > page 139 > page 140
Transformers
& shunts
JVO JVS TRI 700
JVO 40-100S TRI 700 S TRI 700 S TRI 700 S
JVP 1045 B JVO 40-100 90-160 S 1145 S TRI 500 100-200-
bi-rating 50-100/5 A 100-200/5 A 200-500/5 A
tri-rating tri-rating 500/5 A
Accuracy class (according
0.5 0.5 0.2s 0.2s 0.2s 0.5 0.2s 0.2s 0.2s 0.5
to EN 600044-1)
Cable primary
42 mm 40 mm 90 mm 40 mm
(diameter in mm)
63 x 12
Busbar primary (mm) 100 x 40
100 x 12
Cable clamp
(section in mm) 22 to 240 mm2 50 to 240 mm2 50 to 240 mm2 50 to 240 mm2 50 to 240 mm2
50 A
100 A
150 A
Primary 200 A
(secondary 5 A) 300 A
500 A
1000 A
2000 A
109
Info & advice
> Measurement and instrumentation Current transformers (CTs) & shunts
TRANSFORMERS
Function
Current transformers power low-voltage measuring
instruments and isolate them from the network. They
supply their secondary winding with a standard current
proportional to the primary current. They are divided
into four main families:
- wound primaries;
- split-core primaries;
- cable primaries;
- busbar primaries. The transformers accuracy class can then be deduced
These transformers can be used with all types of measuring from the results obtained by referring to the table op-
instruments: posite (provided as an example):
ammeters, energy meters, power monitors, etc. - Class 3 for a CT with a ratio of 150/5
- Class 1 for a CT with a ratio of 200/5
How to choose a current transformer? - Class 0.5 for a CT with a ratio of 250/5
The choice is based on two main criteria:
Power (VA) on Class
- the current on the primary (transformation ratio Ip / 5 A); Primary 0.5 1 3
- the type of installation. 100 A - 1 1.5
In other words, the choice depends on the type of 125 A - 1 1.5
cable or busbar on the installation and the intensity of 150 A 1 1.75 2.5
the currents flowing through them. 200 A 1.5 2.75 3.75
250 A 2 3.25 3.75
300 A 2.5 3.25 4
Determining a CTs accuracy class 400 A
500 A
3
3.5
3.75
3.75
5
5
The accuracy class of a current transformer depends 600 A 3.75 5 7.5
on the transformers apparent power (VA) and the
consumption of the entire measurement line. It is the
result of the measurement errors of each element in
the line and must therefore be less than or equal to Accuracy limit tables according to
the accuracy class of the measuring instrument which the IEC 60044-1 standard
it supplies, particularly for energy metering where
accuracy has a direct impact on billing. For a given Limit errors Table 1
accuracy class, the measurement lines consumption Class Error (in %) depending on In (in %)
must not exceed the current transformers apparent 5 20 100 120
power (VA). 0.2 0.75 0.35 0.20 0.20
0.5 1.50 0.75 0.50 0.50
1 3.00 1.50 1.00 1.00
Example of measurement chain
consumption at 20 C Limit errors Table 2
Power dissipated per metre of line (2 ways) Class Error (in %) depending on In (in %)
1 5 20 100 120
Copper-wire section (mm) Secondary 5 A Secondary 1 A
0.2 S 0.75 0.35 0.20 0.20 0.20
1.5 0.61 0.025 VA 0.5 S 1.50 0.75 0.50 0.50 0.50
2.5 0.37 0.015 VA
4 0.23 0.009 VA
6 0.15 0.006 VA
110
ENERGY PERFORMANCE
SELECTING A TRANSFORMER
POWER QUALITY
Enerdis current transformers offer 4 types of connection:
Transformers
WOUND PRIMARY CABLE PRIMARY BUSBAR PRIMARY SPLIT CORE PRIMARY
& shunts
for currents less than 200 A for currents between 40 and 2,500 A for currents between 750 and 5,000 A for easy connection to an existing installation
using a busbar or cable primary
Supply Use
accuracy class
For a consumption of 12,000 MWh/year and a cost of You must never open the secondary circuit of a CT supplied
e 0.10/kWh on the primary. The very high voltage created may cause
CT class 1: 120,000 kWh = e 12,000 bodily harm or irreparable damage to the transformer.
CT class 0.5: 60,000 kWh = e 6,000 Before working on the secondary of a CT, it must be short-
CT class 0.2S: 2,500 kWh = e 2,500 circuited.
This calculation takes into account neither the class of the When a CT is not in use (secondary open) the secondary must
measuring instruments, nor loss occurring on the network cables. be short-circuited before powering up the system.
111
TCR Range
CTs designed for submetering. Accuracy class 0.5/1/3
> Measurement and instrumentation Current transformers (CTs)
COMPACT DESIGN
POWER QUALITY
75
25 x 25 mm aperture
104.5 M4 and M6 Primary: 16 mm2 wire
82
Secondary: 4 mm2 wire
10.5 10.5 75 40
40
Transformers
50 75
43 32
43 32 52.5 70
& shunts
75 134
108 M6 M4
43 M6 M4 20 48
32
104
104
82
82 PRIMARY
104.5
82
85
45
M10X25 10 5,5
10 5,5
P1 S1 SECONDARY
10.5 10.5 40 5.5 50 P1 S1
50 50 50 P2 S2
80 P2 S2 DIN 46277 (EN 50022)
134 FIXATION
108
50
32 50
Power (VA) class Weight Power (VA) class Weight Power (VA) class Weight
Primary 0.5 M10X25 1 3 (kg) Primary 1 (kg) Primary 0.5 1 3 (kg)
5 A 15 20 30 0.70 5 A 5 0.50 5 A 2.5 5 7 0.28
40
10 A 50 15 5.5 20 30 0.70 10 A 5 0.50 10 A 2.5 5 7 0.28
80
15 A 15 20 30 0.70 15 A 5 0.50 15 A 2.5 5 7 0.28
20 A 15 20 30 0.70 20 A 5 0.50 20 A 2.5 5 7 0.28
25 A 15 20 30 0.70 25 A 5 0.50 25 A 2.5 5 7 0.28
30 A 15 20 30 0.70 30 A 5 0.50 30 A 2.5 5 7 0.28
40 A 15 20 30 0.70 40 A 5 0.50 40 A 2.5 5 7 0.28
50 A 15 20 30 0.80 50 A 5 0.50 50 A 2.5 5 7 0.28
60 A 15 20 30 0.80 60 A 5 0.50
75 A 15 20 30 0.75
100 A 15 20 30 0.70
125 A 15 20 30 0.70
150 A 15 20 30 0.70
T O O R D E R
113
TCR Range
Cable/busbar primary
> Measurement and instrumentation Current transformers (CTs)
49 58 49 60.5
58 64
32 32 44
4.5
4.5
4.5
5.6
5.6
5.6
P2 P2
P2
48
48
80.5
S1 S2 S2
70
15.6
S1 S2
10.6
20.6
70
5.5
20.6
10.6
26
.3
3
P1 P1 P1
20
22.
29
34
29
2.5
2.5
39 39
2.5
58 49 60.5 46
49 64
58 25.6 32 30.6 59 44 30.6
32 59 71
4.5
4.5
5.6
5.6
5.6
P2 P2
P2
80.5
60
248
S2 S1 S2
10.6
48
20.6
S1 S2
6
15.6
70
20.6
10.6
P1
5.5
3
.3
P1 P1
22.
20
34
29
29
2.5
2.5
39 39 46
2.5
30.6
25.6 71
59 30.6 59
Power (VA) class Weight Power (VA) class Weight Power (VA) class Weight
Primary 0.5 1 3 (kg) Primary 0.5 1 3 (kg) Primary 0.5 1 3 (kg)
40 A - - 1.5 0.41 100 A - 1 1.5 0.53 100 A 1.75 3.75 7.5 0.53
50 A - - 3 0.42 125 A - 1 2 0.53 125 A 3.75 7.5 10 0.53
60 A - 1.25 3.5 0.43 150 A 1 2 2.5 0.53 150 A 5 7.5 10 0.53
75 A - 2 3.5 0.44 200 A 2.5 3 3.5 0.54 200 A 7.5 10 10 0.54
100 A 1.5 2.5 3.75 0.44 250 A 3.5 3.75 5 0.54 250 A 7.5 10 15 0.54
125 A 1.75 3.5 5 0.45 300 A 3.5 3.75 5 0.51 300 A 10 10 15 0.51
150 A 2.5 3.5 5 0.29 400 A 3.5 5 7.5 0.51 400 A 10 10 15 0.51
200 A 3.75 5 5 0.30 500 A 5 7.5 10 0.51 500 A 15 15 20 0.51
250 A 5 7.5 7.5 0.31 600 A 5 7.5 10 0.52 600 A 15 20 25 0.51
T O O R D E R
114
ENERGY PERFORMANCE
POWER QUALITY
TCR 51 TCR 61
Cable 28 mm Cable 44 mm
Bar: 20 x 25 mm - 30 x 15 mm Bar: 50 x 30 mm - 60 x 12 mm
40 x 10 mm
64 60.5 84.5 76
Transformers
44
4.5
50
4.5
& shunts
5.6
5.6
P2
60 P2
12.5
30.6
80.5
S1 S2
102
10.6
25.2
60
28.5
44
S1 S2
P1
P1
46
34
2.5
64 60.5 84.5 46 76
50.6
40.6 60.6
44 71
4.5
50 78
5.6
5.6
P2
60
P2
12.5
30.6
S1 S2
10.6
25.2
102
8.5
60
44
P1 S1 S2
P1
46
2.5
46
0.6 50.6
71
60.6
78
T O O R D E R
115
TCR Range
Cable/busbar primary
> Measurement and instrumentation Current transformers (CTs)
TCR 71 TCR 75
Cable 63 mm Bar: 3 x 100 mm x 10 mm
Bar: 50 x 50 mm - 60 x 37 mm
80 x 30 mm
129 50
4,5
108 76
4,5
50
M5 6,6
50
M5
130
50,8
37,6
30,6
63
150
54
86
61
70
50,6
60,6 64 101 78
78
80,6
6,6
P2
6,6
64
S1 S2
P1
64
106
86
M5
78
50
800 A 7.5 10
63
15 0.66 4000 A 35 40 60 1.87
1000 A 10 15 20 0.72
1200 A
4,5 10 15 20
61 0.68
1500 A 15 20 25 0.84
130
2000 A 15 20 25 0.82
2500 A 15 20 30 0.88
3000 A 15 20 30 0.88
T O O R D E R
116
ENERGY PERFORMANCE
TCR Range
Busbar primary
POWER QUALITY
TCR 80 TCR 90 TCR 100
Bar: 100 x 20 mm Bar: 100 x 30 mm Bar: 125 x 60 mm
124 44
95 115 32 32
Transformers
43 32 43 32 60 32
& shunts
38
128
187.5
202.5 193 72
103 103
165
185
55
82.5
27
90
78 62
23 40
59 44
32
63 71 57
Power (VA) class Weight Power (VA) class Weight Power (VA) class Weight
Primary 0.5 1 3 (kg) Primary 0.5 1 3 (kg) Primary 0.5 1 3 (kg)
750 A 15 20 30 0.80 1500 A 15 30 40 0.76 1000 A 15 20 30 0.75
800 A 15 20 30 0.80 2000 A 20 40 50 0.82 1200 A 15 20 30 0.80
1000 A 15 20 30 0.76 2500 A 20 40 50 0.78 1500 A 15 20 30 0.83
1200 A 15 20 30 0.76 3000 A 20 45 60 0.90 2000 A 15 20 30 0.92
1500 A 15 30 40 0.76 4000 A 35 50 70 0.90 2500 A 20 30 40 1.01
2000 A 20 40 50 0.76 3000 A 30 40 60 1.09
4000 A 35 50 70 1.21
5000 A 40 60 80 1.44
T O O R D E R
117
TCRO range
CTs designed for insertion on electrical installations
without opening the conductor.
> Measurement and instrumentation Current transformers (CTs)
PRODUCT
ADVANTAGES
PRIMARY
from 200 to 5,000 A
and wide choice of
primary options
FULLY OPENING
primary
A
> 3CT Mounting
Gmax
D
> Mounting accessories
B B E Dimensions Plate mounting Busbar clamp
Model A B C D E F G Model fittings
TCRO 2030 269 90 40 200 111 122 20 TCRO 2030
TCRO 5080 344 115 32 280 166 98 50 TCRO 5080
C
118
ENERGY PERFORMANCE
POWER QUALITY
TCRO 2030 TCRO 5080 TCRO 8080
Bar: 20 x 30 mm Bar: 50 x 80 mm Bar: 80 x 80 mm
20 20 20 50 50 50 80 80 80
Transformers
& shunts
30 110
30 11030 110 80 145
80 14580 145 80 145
80 14580 145
40 59 40 59 40 59 32 59 32 59 32 59 32 59 32 59 32 59
Power80(VA) class
80 80 Weight 80 Power
80 (VA)
80 class Weight Power (VA) class Weight
Primary 0.5 1 3 (kg) Primary 0.5 1 3 (kg) Primary 0.5 1 3 (kg)
100 A - - 1.5 0.75 250 A 1 2 4 0.90 250 A 1 2 4 1.00
150 A - - 2 0.75 300 A 1.5 3 6 0.90 300 A 1.5 3 6 1.00
200 A - 1.5 2.5 120 0.75
185
120 185120 400
185A 1.5 3 160 245
10 0.90245
160 245160 400 A 1.5 3 10 1.00
250 A - 2 4 0.75 500 A 2.5 5 15 0.90 500 A 2.5 5 15 1.00
300 A 1.5 4 6 0.75 600 A 2.5 5 17.5 0.90 600 A 2.5 5 17.5 1.00
400 A 2.5 6 10 0.75 800 A 3 7 18 0.90 800 A 3 7 18 1.00
144 144 144 1000 A 184 5 184 10 20
184 0.90 1000 A 5 10 20 1.00
32 59 32 59 32 59 52 59 52 59 52 59
T O O R D E R
119
TCRO Range 20 20 50 5080 80
89 89 114 114
144 144
TCRO 80120 40 59 40 32
59 59 TCRO 80160 32325959
80 8080 80
144 144
184 184
32 59 52325959 52 59
T O O R D E R
120
ENERGY PERFORMANCE
TC CLIP Range
Very compact current transformer for inclusion on electrical installations
without disconnecting the power cables
POWER QUALITY
PRODUCT
ADVANTAGES
Transformers
IMPLEMENTATION
& shunts
without cutting off the
power
VERY
COMPACT
PRIMARY
from 100 to 600 A
121
TCC241 / TCC242 TCC364 / TCC366
> Measurement and instrumentation Current transformers (CTs)
Cable 24 mm Cable 36 mm
16.8
23.4
23.4
35.9
91.4
91.4
74.5
64.1
74.5
41.1
47
47
57
57
S1 S2 S1 S2 S1 S2 S1 S2 S1 S2
P1 P2 P1
P2 P1 P2 P1
P2 P1
P1 P2 P2 P1 P1 P2 P2 P1 P1
T O O R D E R
> page 70
122
ENERGY PERFORMANCE
JVR-JVO-JVP Ranges
CTs designed to supply analogue or digital measurement instruments.
Accuracy class 0.5/1/3
POWER QUALITY
PRODUCT
ADVANTAGES Sealable cover
M5 terminals with
2 grooves for dual
COMPLETE RANGE: connection on secondary
Transformers
primary from 1 to 3,000 A
& shunts
and 5 A or 1 A secondary
TOTALLY ADAPTABLE
RANGE
for specific requirements
(primary, secondary,
power class, frequency)
B B E
Dimensions
Model A B C D E F G For 1CT 2CT 3CT
JVO 25 CR 227 76 45 184.5 109.5 137 32.5 model mounting rail mounting rail mounting rail
F
JVO 32 CR 260 87 58 214.5 128.5 176 40.5 JVR ACCE 7652 ACCE 7653 ACCE 7655
JVP 624 296 99 35 220 122 107 22 JVO 12-18 ACCE 7650 ACCE 7651 ACCE 7654
Gmax
A D JVP 1025 344 115 45 252 138 137 22 JVO 21-25-32-36 ACCE 7652 ACCE 7653 ACCE 7655
JVP 1045 404 135 45 312 178 137 42 J3R 80 B ACCE 7640
123
Sealable cover
JVR-JVO-JVP Ranges
79
16.5
42 38
93
79
JVR 64 JVR 75 42
16.5
38
JVR 86 45
16.5/20
45
104,5
79
93
16.5 16.5/20 16.5/20
42 38 45 45 56 58
64 84 75 94/101 86 107/114
2 mounting points (M6) 2 mounting points (M6) 2 mounting points (M6)
Power (VA) class Weight Power (VA) class Weight Power (VA) class Weight
Primary 0.5 1 3 (kg) Primary 0.5 1 3 (kg)
104,5
Primary 0.5 1 3 (kg)
5 A * 5 5 0.45 5 A * 10 10 0.6 5 A * 20 30 1.2
93
T O O R D E R
124
ENERGY PERFORMANCE
JVR-JVO-JVP Ranges
JVO Cable primary
POWER QUALITY
JVO 12-46 JVO 18-51 JVO 21-64
Cable 12 mm Cable 18 mm Cable 21 mm
12 18 21
63 56 70 62
Transformers
79 71
& shunts
29 32 37
30 30 32 30 38
42
46 51 64
2 mounting points (M5) 2 mounting points (M5) 2 mounting points (M6)
Power (VA) class Weight Power (VA) class Weight Power (VA) class Weight
Primary 0.5 1 3 (kg) Primary 0.5 1 3 (kg) Primary 0.5 1 3 (kg)
40 A - - 1.5 0.20 100 A - - 2 0.25 100 A - - 4 0.35
50 A - - 2 0.20 125 A - 2.5 3 0.25 125 A - - 5 0.35
60 A - - 2.5 0.20 150 A - 3 4 0.25 150 A - - 5 0.35
75 A - - 3 0.20 200 A - 4 6 0.25 200 A - 5 5 0.35
100 A - - 4 0.20 250 A - 5 7 0.25 250 A - 5 5 0.35
125 A - - 5 0.20 300 A - 5 8 0.25 300 A * 5 10 0.35
150 A - - 5 0.20 400 A * 5 10 0.35
500 A * 10 20 0.35
600 A * 10 20 0.35
*On request
T O O R D E R
125
JVR-JVO-JVP Ranges
JVO Cable primary
> Measurement and instrumentation Current transformers (CTs)
21 32 36
93 85 93 85 93 85
44 44 44
45 45 45 45 45 45
75 75 75
2 mounting points (M6) 2 mounting points (M6) 2 mounting points (M6)
Power (VA) class Weight Power (VA) class Weight Power (VA) class Weight
Primary 0.5 1 3 (kg) Primary 0.5 1 3 (kg) Primary 0.5 1 3 (kg)
50 A - - 5 0.65 100 A - - 5 0.65 100 A - - 5 0.45
60 A - - 5 0.65 125 A - - 5 0.65 125 A - - 5 0.45
75 A - - 10 0.65 150 A - 5 10 0.65 150 A - - 10 0.45
100 A - 4 10 0.65 200 A - 5 10 0.65 200 A - 5 10 0.45
125 A - 5 10 0.65 250 A * 5 15 0.65 250 A * 5 15 0.45
150 A * 10 15 0.65 300 A * 10 15 0.65 300 A * 5 15 0.45
200 A * 10 15 0.65 400 A * 10 15 0.65 400 A * 5 15 0.45
250 A * 15 20 0.65 500 A * 10 20 0.65 500 A * 10 20 0.45
300 A * 15 20 0.65 600 A * 10 20 0.65 600 A * 20 20 0.45
400 A * 20 30 0.65 *On request *On request
500 A * 30 30 0.65
600 A * 30 30 0.65
*On request
T O O R D E R
Example JVR 32-75 500 A 1A 0.5 10 VA 50 Hz > page 123 > page 143
JVR 21-75
JVR 32-75
JVR 36-75
126
ENERGY PERFORMANCE
JVR-JVO-JVP Ranges
JVO Cable primary
POWER QUALITY
J3R 80 B JVO 25 CR JVO 32 CR
Cable 66 mm Cable 25 mm Cable 32 mm
Bar: 32 x 10 mm Bar: 40 x 10 mm
Transformers
& shunts
32,5 10,5 93 85 40,5 10,5 104,5 96,5
154
44 50
76
66
75 45 56 58
42 86
2 mounting points (M6) 2 mounting points (M6)
Power (VA) class Weight Power (VA) class Weight Power (VA) class Weight
Primary 0.5 1 3 (kg) Primary 0.5 1 3 (kg) Primary 0.5 1 3 (kg)
200 A - 5 10 1.6 100 A - - 5 0.6 100 A - - 5 0.9
250 A - 5 10 1.6 125 A - - 5 0.6 125 A - - 10 0.9
300 A 5 10 15 1.6 150 A - - 5 0.6 150 A - 5 15 0.9
400 A 10 20 25 1.6 200 A - 5 10 0.6 200 A - 5 15 0.9
500 A 15 20 25 1.6 250 A * 5 15 0.6 250 A * 10 20 0.9
600 A 15 20 25 1.6 300 A * 5 15 0.6 300 A * 10 30 0.9
750 A 15 20 25 1.6 400 A * 10 15 0.6 400 A * 15 30 0.9
800 A 15 20 25 1.6 500 A * 20 20 0.6 500 A * 15 30 0.9
1000 A 15 20 25 1.6 600 A * 20 20 0.6 600 A * 15 30 0.9
1250 A 15 20 25 1.6 *On request *On request
1500 A 15 20 25 1.6
T O O R D E R
Example JVR 25 CR 600 A 1A 0.5 10 VA 60 Hz > page 123 > page 143
J3R 80 B
JVO 25 CR
JVO 32 CR
127
JVR-JVO-JVP Ranges
JVP Busbar primary
> Measurement and instrumentation Current transformers (CTs)
Power (VA) class Weight Power (VA) class Weight Power (VA) class Weight
Primary 0.5 1 3 (kg) Primary 0.5 1 3 (kg) Primary 0.5 1 3 (kg)
100 A - - 5 1.2 200 A - - 5 2 300 A - 5 5 2.5
125 A - - 5 1.2 250 A - - 5 2 400 A * 5 10 2.5
150 A - - 5 1.2 300 A - 10 20 2 500 A * 10 15 2.5
200 A - - 5 1.2 400 A * 5 30 2 600 A * 15 15 2.5
250 A - 5 15 1.2 500 A * 15 15 2 750 A * 20 20 2.5
300 A - 5 15 1.2 600 A * 15 15 2 800 A * 20 20 2.5
400 A 750 A * 20 20 2
* 10 15 1.2 800 A
1000 A * 30 30 2.5
500 A * 15 20 1.2 * 20 30 2 1250 A * 30 30 2.5
600 A 1000 A * 30 30 2
* 20 20 1.2 1250 A
1500 A * 30 30 2.5
750 A * 30 30 2
* 20 20 1.2 1500 A
2000 A * 30 30 2.5
800 A * 30 30 2
* 20 20 1.2 2000 A * 30 30 2
2500 A * 30 30 2.5
1000 A * 20 20 1.2 2500 A 3000 A * 30 30 2.5
* 30 30 2
*On request 3000 A *On request
* 30 30 2
*On request
T O O R D E R
128
ENERGY PERFORMANCE
JVS Range
CTs designed to supply IEC 687 electronic measurement instruments,
power monitors, digital transducers, etc.
POWER QUALITY
PRODUCT
ADVANTAGES Captive sealable
terminal covers
CHOICE OF PRIMARY
Transformers
from 100 to 5,000 A
& shunts
ACCURACY CLASS:
0.2 S for high-performance
applications
129
JVS Range
Cable/busbar primary
> Measurement and instrumentation Current transformers (CTs)
4.5
4.5
5.6
5.6
P2 P2
60
80.5
80.5
60
S1 S2
10.6
S1 S2
25.2
10.6
20.6
28,5
26
P1 P1
34
34
2.5
2.5
46 46
60.5 30.6 60.5 40.6
64 71 64
44 71
44
4.5
5.6
5.6
Cable 26 mm Cable 28 mm
P2 P2
Bar: 20 x 20 mm Bar: 20 x 25 mm
60
60
80.5
S1 S2 S1 S2
10.6
20.6
10.6
25.2
28,5
26
P1 P1
25 x 12 mm 30 x 15 mm
34
30 x 10 mm 40 x 10 mm
2.5
2.5
46 46
30.6 40.6
71 71
T O O R D E R
130
ENERGY PERFORMANCE
JVS Range
Cable/busbar primary
POWER QUALITY
JVS 30B JVS 38B JVS 39B
Cable 44 mm Cable 63 mm Bar: 3 x 100 x 10 mm
Bar: 50 x 30 mm Bar: 50 x 50 mm
60 x 12 mm 60 x 30 mm
80 x 30 mm
84.5 69 108 50
4.5
50 129
Transformers
4.5
4.5
50 M5 6.6
& shunts
5.6
50
P2 M5
12.5
30.6
130
50.8
37.6
30.6
102
60
44
63
S1 S2
P1
86
150
46
54
61
50.6
70
50.6
60.6
69 78 60.6 64
78 101 78
50 80.6
5.6
6.6
6.6
P2 P2
60
64
S1 S2
64
S1 S2
P1 P1
106
86
M5
78
78
50
63
1200 A 10 0.63 2500 A 10 0.88 4000 A 25 1.83
1500 A 10 0.65 3000 A 10 0.88
61
4.5
130
T O O R D E R
131
JVS Range
Busbar primary
> Measurement and instrumentation Current transformers (CTs)
JVS 40 JVS 50
Bar: 100 x 20 mm Bar: 100 x 30 mm
115
95 43 32
43 32
187,5 202,5
165
103 103
180
82,5
90
40
23 44
59 32
63
T O O R D E R
132
ENERGY PERFORMANCE
POWER QUALITY
JVS 60
Bar: 125 x 60 mm
124 44
32 60 32
32
Transformers
38
& shunts
193 72
128
55
27
78 62
71 57
T O O R D E R
Primary Secondary 5A
1000 A JVS60-1000/5
1500 A JVS60-1500/5
2000 A JVS60-2000/5
2500 A JVS60-2500/5
3000 A JVS60-3000/5
4000 A JVS60-4000/5
5000 A JVS60-5000/5
133
Single-phase, single-rating: JVP1045B
Transformers for tariff metering
JVP1045 B
> Measurement and instrumentation Current transformers (CTs)
Busbar primary
PRODUCT
ADVANTAGES
DELIVERED
WITH SEALABLE
PROTECTIVE COVER
for the secondary.
Simple M5 terminals
DIRECT MOUNTING
on primary busbar by
means of plate and
tightening screw or panel
mounting with mounting
plate
T O O R D E R
Barre 100 x 40 mm 65
Power (VA) in class 0.5 Weight Capot
plombable
7.5 15 (kg)
Primary Secondary 5A
181,5
105
134
ENERGY PERFORMANCE
Single-phase, single-rating: JVO 40-100
Transformers for tariff metering
JVO 40-100
POWER QUALITY
Cable primary
PRODUCT
ADVANTAGES
DELIVERED
Transformers
WITH SEALABLE
& shunts
TERMINAL COVER
for the secondary.
Simple M5 terminals with
two grooves for double
connection
MOUNTING ON
SYMMETRICAL
MOUNTING RAIL
or panel mounting
T O O R D E R
100
3-CT mounting rail ACCE 7681
135
Single-phase, multi-rating: JVO 40-100 S
Transformers for tariff metering ERDF application
JVO 40-100 S
> Measurement and instrumentation Current transformers (CTs)
Cable primary 40 mm
PRODUCT
ADVANTAGES
CLASS 0.2s
ACCORDING TO
IEC60044-1
Particularly SUITABLE
FOR ERDF-QUALIFIED
BI-RATING AND
TRI-RATING
ELECTRONIC METERS
> Dimensions
Bi-rating
136
ENERGY PERFORMANCE
Single-phase, multi-rating: JVO 90-160 S
Transformers for tariff metering ERDF application
JVO 90-160 S
POWER QUALITY
Cable primary 90 mm
PRODUCT
ADVANTAGES
CLASS 0.2s
Transformers
& shunts
ACCORDING TO
IEC60044-1
Particularly SUITABLE
FOR ERDF-QUALIFIED
TRI-RATING
ELECTRONIC METERS
> Dimensions
137
Single-phase, multi-rating: JVP 1145 S
Transformers for tariff metering ERDF application
JVP 1145 S
> Measurement and instrumentation Current transformers (CTs)
Cable primary
PRODUCT
ADVANTAGES
CLASS 0.2s
ACCORDING TO
IEC60044-1
Particularly SUITABLE
FOR ERDF-QUALIFIED
TRI-RATING
ELECTRONIC METERS
> Dimensions
138
ENERGY PERFORMANCE
Single-phase, multi-rating: TRI 500
Transformers for tariff metering
TRI 500
POWER QUALITY
PRODUCT
ADVANTAGES
Compliant
Transformers
with NF-C-42-502
& shunts
standard
Designed for
three-phase LV
metering
> General specifications
Maximum network voltage: 500Vac
Dielectric test voltage: 2 kV - 50 Hz - 1 min
Rated withstand voltage: 8 kV
Frequency response: 50 Hz
Primary via cable clamp: conductors from 50 to 240 mm2
Input
measurement
Output
32
430
Thickness of
the base
= 20
70
107
67 60 60 55
T O O R D E R
Primary 5A Secondary
Power (VA) Weight
Primary Class 0.5 (kg) 50 A TRI5 7823
50 A 15 7.50 100 A TRI5 7825
100 A 15 7.50 150 A TRI5 7826
150 A 15 7.50
200 A TRI5 7827
200 A 15 7.50
300 A 15 7.50 300 A TRI5 7828
500 A 15 7.50 500 A TRI5 7831
139
Three-phase, multi-rating: TRI 700
Transformers for tariff metering ERDF application
> Measurement and instrumentation Current transformers (CTs)
PRODUCT
ADVANTAGES
CHOICE OF PRIMARY
CONDUCTOR type: copper
> General specifications
Primary via cable clamp: Rated thermal current:
or aluminium Conductor cross-section from 50 mm to 240mm Bi-rating / tri-rating model: 1.2 Ipn
Transformation ratio: Operating temperature:
B uilt-in short-circuiting TRI700S bi-rating model 50 A - 100 A / 5 A Bi-rating / tri-rating model: -25C to +40C
switch TRI700S bi-rating model 100 A - 200 A / 5 A Type of casing:
TRI700S bi-rating model 200 A - 500 A / 5 A Bi-rating / tri-rating model:
TRI700 tri-rating model 100 A - 200 A - 500A / 5 A Self-extinguishing thermoplastic (UL94V0)
Accuracy class: Protection rating:
Bi-rating model 0.2s; tri-rating model: 0.5 With additional cover: IP40
Precision power: Mechanical shock resistance:
Bi-rating model: 7.5 VA; tri-rating model: 3.75 VA Bi-rating / tri-rating model: (IK7)
Maximum network voltage: Rated withstand voltage:
Bi-rating / tri-rating model: 720 Vac Bi-rating / tri-rating model: 3 kV
Rated frequency: (RMS value) at 50 Hz for 1 minute
Bi-rating / tri-rating model: 50/60 Hz Lightning impulse withstand voltage:
Rated thermal short-circuit current (Ith): Bi-rating / tri-rating model:
Bi-rating / tri-rating model: (8 kV) (peak value) Wave 1.2/50 s
80 Ipn with a maximum of 20 kA for 1 s Insulation class:
Rated dynamic current (Idyn): Bi-rating / tri-rating model:
Bi-rating / tri-rating model: 2.5 Ith E (heating limit: 75 K)
Safety factor: Weight: Bi-rating / tri-rating model: 7 Kg
TRI700S 50 - 100 / 5 A:
FS = 2.3 (50 A); FS = 4.2 (100 A)
TRI700S 100-200/5 A: T O O R D E R
FS = 2.3 (100 A); FS = 4.2 (200 A) Model Reference
TRI700S 200 - 500 / 5 A:
TRI 700 tri-rating P01379514
FS = 2,3 (200 A); FS = 5 (500 A)
TRI700 100 - 200 - 500 / 5 A: TRI 700 S bi-rating 50 - 100 / 5 A P01379515
FS = 3 (100 A); FS = 4 (200 A); FS = 6 (500 A) TRI 700 S bi-rating 100 - 200 / 5 A P01379516
TRI 700 S bi-rating 200 - 500 / 5 A P01379517
> Dimensions
140
ENERGY PERFORMANCE
Current summation: JVM 15
CT designed for adding or subtracting instantaneous values from the
secondaries of 2 or 3 current transformers. Used to supply measuring or
metering instruments on installations with several feeder and feed points.
POWER QUALITY
PRODUCT
ADVANTAGES
COMPACT DESIGN
Transformers
& shunts
M
ounting on plate
or rail
Operating conditions:
Temperature: -5C to +60C
Relative humidity: 93% at 40C Power (VA) class Weight
Protection: Primary 0.5 1 3 (kg)
Protection rating: 5+5 A 15 20 30 1.20
IP 40 (module casing) and IP 10 (terminals) 5+5+5 A 15 20 30 1.20
Dry winding with self-extinguishing ABS
covering (UL 94 VO)
Primary Secondary 5A
Model 1 CT slide 2 CT slide 3 CT slide 5+5 A JVMA 7523
rail mounting rail mounting rail mounting 5+5+5 A JVMA 7524
JVM 15 ACCE 7652 ACCE 7653 ACCE 7655 Sealable cover ACCE 7668
141
Current summation: TCS
CT designed to add together the instantaneous current values
from the secondaries of 2 to 4 current transformers. In this way,
it provides data for the measurement or metering equipment
> Measurement and instrumentation Current transformers (CTs)
PRODUCT
ADVANTAGES
MADE-TO-MEASURE
PRODUCT
with different totalized
CT ratios
> Dimensions
Power (VA) in class 0.5 Weight
6 0.9 kg
T O O R D E R
Primary 5 A Secondary
5+5 A TCS 02N
5+5+5 A TCS 03N
5+5+5+5 A TCS 04N
Different primary
5+5 A TCS 02C
5+5+5 A TCS 03C
5+5+5+5 A TCS 04C
142
ENERGY PERFORMANCE
Transformer short-circuit switch
Protection against the dangers caused by opening the secondary
circuit on low-voltage measurement CTs
POWER QUALITY
PRODUCT Mounting on DIN
rail or plate
ADVANTAGES
PROTECTS USERS
Transformers
AND EQUIPMENT
& shunts
AGAINST
OVERVOLTAGES
caused by opening the
CT 5 A or 1 A secondary
AUTOMATIC
SHORT-CIRCUITING
of CT secondary to which
it is permanently connected
Equipment connected on
CT secondary side can be
operated by user without Four terminals
supply interruption available for 6 mm2 wires Connection diagram
143