GE Hydril Catalogo PDF
GE Hydril Catalogo PDF
GE Hydril Catalogo PDF
Key Features
Designed specifically for subsea drilling applications, the
Hydril Pressure Control Annu-Flex enhances the best of
our GX annular BOPs performance and serviceability with
several distinguishing features:
A flex-joint design eliminates friction that causes binding
and galling as well as the need for lubrication and pressure
compensation commonly found in ball-type designs
An elastomer element, the key component of the subsea
flexible joint, is permanently bonded to an inner housing
and outer ring
A guide ring/wear bushing absorbs through-the-bore wear
during normal operations to protect the elastomer element
and the main housing
A housing/latched head to retain full working pressure rating
The Hydril Pressure Control Annu-Flex
Advantage
Only the Hydril Pressure Control Annu-Flex can offer the
performance and serviceability of our GX annular BOP in a
unit designed specifically for subsea drilling applications. With
its compact design and distinctive flex joint, the Annu-Flex
decreases overall stack height to free up critical space and
require fewer stack connections.
Engineering Data
DUAL SINGLE
Bore (inches) 18.75 18.75
Working Pressure (psi) 10,000 10,000
Hydraulic Operating Pressure (psi) 1,500 1,500
Gal. to Close (U.S. gal.) 58 per BOP 58
Gal. to Open (U.S. gal.) 58 per BOP 58
Stud to flange height (inches) Flanged Bottom 10 m 174.45 116.45
15 m 177.42 119.42
Clearance Diameter (inches) 84.00 84.00
Weight (lbs.) 112,118 65,000
GE imagination at work
2010 General Electric Company. All rights reserved.
HY_Annu-Flex_FS_080610
GE Oil & Gas
Drilling & Production
Key Features
Field-replaceable upper seal seats, bottom wear plates and
hydraulic manifold virtually eliminate the need to move the
unit to an authorized repair facility for service
The Hydril Pressure Control Compact Ram
Advantage
Since our engineers invented the annular BOP, world leaders Because testing requirements are becoming increasingly
in oil and gas drilling have depended on Hydril Pressure severe, we have upgraded test center capabilities well
Control equipment for reliable performance in applications beyond the HPHT limits sought by the industry today.
with extreme pressures, temperatures and other unusual Current capabilities include:
challenges. High-temperature testing to 500 F
Low-temperature testing to -80 F
We push the boundaries of pressure control every day at our
High-pressure testing to 50,000 psi
state-of-the-art testing facilities. Even when testing pushes
Shear testing for large-diameter and heavy-wall pipe
Hydril Pressure Control equipment beyond its capabilities,
Pressure testing with hang-off loads up to 600,000 lbs
we learn what failed, why and how. This knowledge forms
External Hydrostatic testing to 7,000 psi
a growing base for new and improved products. From it, we
identify new design goals to take pressure control even further.
Engineering Data
Extended Double
Bore (inches) 18.75 18.75 18.75 18.75
Working Pressure (psi) 5,000 10,000 15,000 15,000
Recommended Hydraulic Operating Pressure (psi) 1,500 1,500 1,500 1,500
Gal. to Close (U.S. gal.) Operator 22.00" - - 39.3 39.3
Operator 19.00" 29.7 29.7 29.2 29.2
Operator 15.50" - - 19.5 19.5
Operator 14.25" 16.4 16.4 - -
Gal. to Open (U.S. gal.) Operator 22.00" - - 36.6 36.6
Operator 19.00" 28.1 28.1 26.5 26.5
Operator 15.50" - - 16.8 16.8
Operator 14.25" 14.9 14.9 - -
Closing Ratio Operator 22.00" - - 14:64:1 14:64:1
Operator 19.00" 18:9:1 18:9:1 10:49:1 10:49:1
Operator 15.50" - - 7:27:1 7:27:1
Operator 14.25" 10:6:1 10:6:1 - -
Stud to Flange Height (inches) 59.00 63.00 75.00 60.00
Stud to Flange Weight (pounds) 34,000 35,000 53,100 31,000
Length (inches) 142.50 142.50 146.60 146.60
GE imagination at work
2010 General Electric Company. All rights reserved.
GE_HY_CRBOP_FS_080610
GE Oil & Gas
Drilling & Production
Key Features
The GK makes maintenance easy and lengthens the time
between packing unit changes and shop repairs. The key to
these benefits is a simple design that includes:
A single packing unit that closes on any size pipe or open
hole and handles stripping
Only two moving parts: the piston and packing unit, for
less wear and maintenance
An optional latched head for fast, easy access to the
packing unit and wear seals; the majority of GK annulars
have a screwed head design
The Hydril Pressure Control GK Advantage
The packing unit for the GK annular BOP can hold full-rated When the GK closes, the piston moves up, driving the
working pressure and will close on an open hole. Before elastomer and inserts inward where they quickly reach a
shipment, each packing unit is factory tested in a BOP to fixed position and form a steel ring that prevents the rubber
50% of working pressure on open hole and 100% on pipe. from moving upward under wellbore pressure. After the ring
The GK provides longer life when using genuine Hydril is formed, feedable elastomer continues to flow inward around
Pressure Control packing units, as shown in repeated testing. the inserts to create a positive seal on the drill string or open
hole. Because the elastomer is primarily in compression, it
resists tears, cuts and abrasions.
Engineering Data
Bore (inches) 7.0625 7.0625 7.0625 7.0625 7.0625 9.00 9.00 9.00 11.00 11.00
Working Pressure (psi) 3,000 5,000 10,000 15,000 20,000 3,000 5,000 10,000 3,000 5,000
Head Type Screwed Screwed Screwed Screwed Screwed Screwed Screwed Screwed Screwed Screwed
Hydraulic Operating Pressure (psi) 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500
Gal. to Close (U.S. gal.) 2.85 3.86 9.42 11.2 10.9 4.33 6.84 15.9 7.43 9.81
Gal. to Open (U.S. gal.) 2.24 3.3 7.08 7.5 7.2 3.41 5.8 11.95 5.54 7.98
Stud to Flange Height (inches) Flanged Rated 32.00 36.88 48.13 54.13 59.00 37.88 41.75 55.75 39.75 47.81
Bottom
5m - 36.88 - - - - 41.75 - - 47.81
10 m - - 48.13 - - - - 55.75 - 48.56
15 m - - 48.75 54.13 - - - - - -
Stud to Flange Weight (pounds) Flanged Rated 2,715 4,000 12,200 14,250 23,000 3,500 6,000 18,540 5,500 8,200
Bottom
5m - 4,000 - - - - 6,000 - - 8,200
10 m - - 12,200 - - - - 18,540 - -
15 m - - - 14,250 - - - - - -
Clearance Diameter (inches) 32.25 35.75 49.50 61.00 58.00 34.50 41.00 56.75 40.00 44.25
Bore (inches) 11.00 11.00 11.00 13.625 13.625 13.625 13.625 13.625 16.75 16.75
Working Pressure (psi) 5,000 10,000 10,000 3,000 3,000 5,000 5,000 10,000 5,000 5,000
Head Type Latched Screwed Latched Screwed Latched Screwed Latched Latched Screwed Latched
Hydraulic Operating Pressure (psi) 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500
Gal. to Close (U.S. gal.) 9.81 25.1 25.1 11.36 11.36 17.98 17.98 37.18 28.7 28.7
Gal. to Open (U.S. gal.) 7.98 18.97 18.97 8.94 8.94 14.16 14.16 12.59 19.93 19.93
Stud to Flange Height (inches) Flanged Rated 48.25 63.50 63.38 45.25 45.25 54.13 54.50 71.31 61.25 61.30
Bottom
5m 48.25 - - - - 54.13 54.50 - 61.25 61.30
10 m 49.00 63.50 63.38 - - 56.18 59.44 71.31 - -
15 m - 65.81 - - - - - - - -
Stud to Flange Weight (pounds) Flanged Rated - 26,140 - 8,784 - 13,800 13,250 - 20,835 21,230
Bottom
5m - - - - - 13,800 13,250 - 20,835 21,230
10 m - 26,140 - - - 14,500 13,900 - - -
15 m - - - - - - - - - -
Clearance Diameter (inches) 44.25 61.50 60.75 47.50 47.50 52.25 52.25 68.13 59.50 59.50
GE imagination at work
2010 General Electric Company. All rights reserved.
HY_GKBOP_FS_080610
GE Oil & Gas
Drilling & Production
Key Features
The key to the GLs excellent performance lies in its unique
design, which includes:
A Hydril Pressure Control packing unit that is specially
molded with two different styles of inserts to reduce closing
volume and increase closing cycles
A replaceable wear plate that eliminates metal-to-metal
contact between the packing unit inserts and the BOP head
A piston design that provides complete balance, more
reliable operation and ease of assembly
A latched head for fast, easy access to the packing unit
and wear seals
An opening chamber head that prevents debris from falling
into the chambers when replacing the packing unit
The Hydril Pressure Control GL Advantage
The GLs Long Life (LL) Packing Unit has been specifically
designed and tested to provide unsurpassed performance
and durability. In performance tests, it outlasted other
replacement units by a minimum of 5-to-1. The key to this
remarkable performance is a revolutionary asymmetrical
insert design which provides longer life and reliability. The
LL Packing Unit is designed to provide greater fatigue life
without compromising stripping performance and operating
characteristics.
Engineering Data
Bore (inches) 18.75 Dual 18.75 21.25
Working Pressure (psi) 5,000 5,000 5,000
Hydraulic Operating Pressure (psi) 1,500 1,500 1,500
Gal. to Close (U.S. gal.) 44 44 58
Gal. to Open (U.S. gal.) 44 44 58
Stud to Flange Height (inches) Flanged bottom 5m 65.25 112.00 77.50
10 m - - 84.25
Stud to Flange Weight (lbs) Flanged bottom 5m 35,000 63,100 45,000
10 m - - -
Clearance Diameter (inches) 76.00 76.00 78.25
GE imagination at work
2010 General Electric Company. All rights reserved.
GE_HY_GLABOP_FS_080610
GE Oil & Gas
Drilling & Production
Key Features
Well suited for surface and subsea operations, the GX makes
maintenance easy and lengthens the time between packing
unit changes and shop repairs. The key to these benefits is a
simple design that includes:
A single packing unit that closes on any size pipe or an
open hole and handles stripping
Only two moving parts, the piston and packing unit, for
less wear and maintenance
The Hydril Pressure Control GX Advantage
The packing unit for the GX annular BOP can hold full-rated a positive seal on the drill string or open hole. Because the
working pressure after more closing cycles and stripping elastomer is primarily in compression, it resists tears, cuts
than any other unit available. The GX produces extra uptime and abrasions.
from a significantly larger reservoir of engineered elastomer,
When stripping, the steel inserts again remain fixed. As
and a BOP design that precisely controls the position of
various diameters of pipe and tool joints pass through the
unique, flanged steel inserts.
closed unit, the elastomer flows in and out. Even at higher
When the GX closes, the packing unit rubber drives the inserts wellbore pressures, the GX packing unit maintains precise
inward, where they quickly reach a fixed position and form a control of seal-off tightness to permit a slight leak of drilling
steel ring that prevents the elastomer from extruding upward fluid that provides lubrication, optimizes pull-through forces
under wellbore pressure. After the ring is formed, feedable and further prolongs packer life.
elastomer continues to flow inward around the inserts to create
No matter what type of severe service awaits your BOPs,
expect more from the genuine Hydril Pressure Contol GX.
Engineering Data
Bore (inches) 11.00 11.00 13.625 13.625 18.75
Working Pressure (psi) 10,000 15,000 5,000 10,000 10,000
Hydraulic Operating Pressure (psi) 1,500 1,500 1,500 1,500 1,500
Gal. to Close (U.S. gal.) 17.9 24.1 15.5 24.1 58
Gal. to Open (U.S. gal.) 17.9 24.1 15.5 24.1 58
Stud to Flange Height (inches) Flanged bottom 5m - - 52.32 - -
10 m 57.12 - 54.31
15 m 59.44 - - 65.38 82.50
Stud to Flange Weight (pounds) Flanged bottom 5m - - - - -
10 m 21,385 - - 28,000 52,250
15 m 22,085 - - 28,885 54,360
Clearance Diameter (inches) 60.38 67.12 58.00 64.50 84.00
GE imagination at work
2010 General Electric Company. All rights reserved.
GE_HY_GXABOP_FS_080910
GE Oil & Gas
Drilling & Production
Key Features
Hydril Pressure Control IP dampeners are compact, easy to
handle and install, and generally do not require external
support. With an isolated body cavity that confines process
fluid to an elastomeric bladder, the IP features a cost-effective
carbon steel shell and a field-replaceable bottom plate the
only wetted shell material. Superior corrosion resistance
means IPs are especially well suited for corrosive applications
including waste disposal, salt water injection, and use with
acidic and caustic substances. Additional features include:
Capacities from 0.5 to 20 gallons
Elastomeric bladders for a variety of applications
Customized bottom connections and bottom plate materials
for use with most process liquids
The Hydril Pressure Control IP Advantage
Offering outstanding performance and a wide range of production operations. Combining efficiency and reliability
compatibility options, Hydril Pressure Control IP dampeners/ with superior corrosion resistance, these are the dampeners
accumulators were designed specifically for industrial and of choice for surge absorption, thermal expansion and
hydraulic accumulator applications.
Engineering Data
275 PSI Pressure Rating
Dimensions (inches)
Capacity (Gal) Model No. Width Shell Height Overall Height Weight (lbs)
See Note
1 IP-1-275 10.50 10.00 16.25 70
2 IP-2-275 12.75 11.50 17.50 85
5 IP-5-275 16.25 14.50 20.625 130
10 See Note
20 SS-20-275 24.00 20.75 27.00 450
NOTE: For 10-gallon units, use IP-10-1440 with ANSI 150 connections. For 1/2-gallon units, use IP-1/2-3600 with ANSI 150 connections.
NOTE: For 1/2-gallon unit, use IP-1/2-3600 with ANSI 600 connections.
GE imagination at work
2010 General Electric Company. All rights reserved.
HY_IPDampener_FS_080610
GE Oil & Gas
Drilling & Production
Key Features
Introduced more than 50 years ago, Hydril Pressure Control K
accumulators/dampeners have earned their reputation
for dependability and durability. A torispherical body shape
results in smoother flow and longer diaphragm life. A stabilizer
disk enhances reliability. And a field-replaceable bottom
plate eliminates costly shop repairs for greater efficiency
and economy. In addition, all our K units:
Are available in a variety of capacities, from 10 to 80 gallons
Meet a variety of specifications manufactured to DNV, CRN,
CE, ATEX, ABS-CDS and ISO 9001
Include ASME code stamping standard on most sizes, and
pressure ratings
The Hydril Pressure Control K Advantage
Proven onshore and off, our K pulsation dampeners are highly
effective under the toughest field conditions. All models are
engineered for reliability, long life and ease of operation. By
manufacturing our own elastomers, we also offer unrivaled
quality control as well as proven materials, compatibility and
availability.
Engineering Data
10 (GAL) CAPACITY
Dimensions (inches)
Model No. Width Shell Height Overall Height Weight (lbs)
K10-275 23.00 23.75 31.10 440
K10-1440 23.00 23.75 31.10 440
K10-3000 23.00 23.75 31.10 950
K10-5000 23.00 23.75 31.10 950
20 (GAL) CAPACITY
Dimensions (inches)
Model No. Width Shell Height Overall Height Weight (lbs)
SS-20-275 24.00 20.75 27.00 450
K20-1440 25.10 26.70 34.10 825
K20-3000 28.50 28.15 35.53 2,145
K20-5000 28.50 28.15 35.53 2,145
20-7500 30.50 29.50 37.60 3,150
80 (GAL) CAPACITY
Dimensions (inches)
Model No. Width Shell Height Overall Height Weight (lbs)
K80-275 38.29 37.31 44.69 2,575
K80-720 38.29 37.31 44.69 2,575
K80-1440 38.29 37.31 44.69 2,575
K80-2000 41.50 38.82 46.20 3,150
K80-3000 41.50 38.82 46.20 3,150
K80-3705 41.50 38.82 46.20 3,150
GE imagination at work
2010 General Electric Company. All rights reserved.
HY_KPulsDamp_FS_080610
GE Oil & Gas
Drilling & Production
C-PASAFE R-PASAFE
Key Features Engineering Data
Hydril Pressure Control PASAFE dampeners are extremely Outside
effective at reducing pulsation created by the stop and start Overall Width Diameter of
Item (inches) Body (inches) Weight (lbs)
motion of reciprocating pumps, as well as the acceleration-
R12-3600 25.00 18.00 310
induced water hammer caused by opening and closing of
R14-3705 33.00 21.00 360
the pump check valve. Their maintenance-free engineering
eliminates the need for internal parts replacement ever R24-1480 35.50 24.00 550
and ensures effective, trouble-free performance even under R80-5000 40.00 39.50 2,325
The Hydril Pressure Control PASAFE C001-1200SS or AXN 1.00 31.00 4.50 60
GE imagination at work
2010 General Electric Company. All rights reserved.
HY_PASAFE_PulsDamp_FS_080910
GE Oil & Gas
Drilling & Production
Engineering Data
GE imagination at work
2010 General Electric Company. All rights reserved.
GE_HY_QLRAMBOP_FS_080910
GE Oil & Gas
Drilling & Production
Universal seal-off
The HVR has a universal seal-off feature that is especially
useful on a drill string that does not have a constant Variable ram
diameter over its length or when multiple diameters of drill
pipe are used. Two BOPs with variable rams can be used on
a tapered string to provide a backup for all drill-pipe sizes.
This application eliminates having one pipe ram for small
diameter pipe and one for large diameter pipe.
of wear over time, or if the ram blocks are changed to 1834 5,000 278 - 5 3112204
Conventional
accommodate a different pipe size. 4 - 7 3112205
1834 5,000 278 - 5 3117341
Compact
Tested in the lab. Proven in the field. 3 - 5 3118836
rams has been proven by extensive testing in the lab 1834 10,000 3 - 5 3118836
and commercial use on wells operated around the world. 4 - 7 3117342
Lab testing conducted per API 16A procedures includes: 15,000 3 - 5 3116833
fatigue testing that has simulated over 1.5 years of service 5-7 3116836
by numerous cyclic operations, pressure tests of the ram 4 - 7 3118844
packers, and temperature testing to determine the high 2034 3,000 278 - 5 3112204
and low temperature limits of our standard packers. 4 - 7 3112205
21 4
1
2,000 2 8 - 5
7
3112204
5,000
2,000 4 - 7 3112205
5,000
Ram sizes for Hydril Pressure Control blowout preventers 18-15 rAM BOP ELASTOMER TEMPERATURE RATINGS
Bore Size (inches) 18-15 Compact/Conventional
Pipe Size 7 16
1
9 11 13 8
5
18 43
20 4
3
21 4
1
Ram Type Ram Size Cold Temperature Hot Temperature
Rating (F) Rating (F)
Wireline
Shear Pipe All 20 500
1.315 4 x 7 30 350
5 x 758 30 180
1.660
1.9
13-15 QUIK-LOQ RAM BOP ELASTOMER TEMPERATURE RATINGS
2116
13-15 Quik-Loq
2 8
3
658 **
7
758
858
958
1034
1338
16
* Hanging rams are standard for 1358-15,000, 1834-10,000, 1834-15,000 and are
optional for 1358-5000, 10,000, 2034-3000, 2114-2000, and 2114-5000.
**
Pipe ram 18" 658: This pipe ram is also good for Grant Prideco pipe ram 658 V150
drill pipe.
GE imagination at work
HY_Rams_081910
GE Oil & Gas
Drilling & Production
Engineering Data
3,000 psi BOP 5,000 psi BOP
Bore 7.0625" 180 mm 7.0625" 180 mm
Working Pressure 3,000 psi 21 mPa 1,500 psi 10.3 mPa
Hydraulic Operating Pressure 1,500 psi 10.3 mPa 10,000 psi 690 mPa
Gal. to Close .33 gal 1.25 L .33 gal 1.25 L
Gal. to Open .31 gal 1.16 L .31 gal 1.16 L
Closing Ratio 4.8:1 4.8:1 4.8:1 4.8:1
Stud to Flange Height Flange Bottom Double 22.06" 560.3 mm 22.06" 560.3 mm
Single 13.06" 331.7 mm 13.06" 331.7 mm
Stud to Flange Weight Flange Bottom Double 2,450 lbs 1,111 kg 2,450 lbs 1,111 kg
Single 1,450 lbs 658 kg 1,450 lbs 658 kg
Length 65.44" 1,662 mm 65.00" 1,662 mm
GE imagination at work
2010 General Electric Company. All rights reserved.
HY_SentryDW_FS_080910