FluidSIMENUS PDF
FluidSIMENUS PDF
FluidSIMENUS PDF
Users Guide
05/15
FluidSIM is a teaching tool for simulating pneumatics, hydraulics,
electrics/electronics and digital technique. It can be used in combi-
nation with the Festo Didactic GmbH & Co. KG training hardware,
but also independently. FluidSIM was developed as a joint venture
between the University of Paderborn, Festo Didactic GmbH & Co.
KG, Denkendorf, and Art Systems Software GmbH, Paderborn.
Contents
1. Welcome! 14
2. Installation 17
3. First steps 21
5. Edit circuit 33
6. Drawing frame 56
Index 685
Chapter 1
1. Welcome!
Welcome to FluidSIM!
Electro-pneumatics/vacuum technology
Electro-hydraulics/mobile hydraulics
Electrical engineering/electronics
Digital technology
GRAFCET
For the first time you can link all technologies in FluidSIM in a single
circuit or project. This means that if you have purchased all three
technology versions, you can utilize pneumatic, hydraulics, control
technology, electronics, digital technology etc. in any way you want
info@fluidsim.de
did@de.festo.com
You can also find the newest version on the following websites:
www.fluidsim.de
www.festo-didactic.de
Chapter 2
2. Installation
With your purchase of the full version of FluidSIM, you received one
or more DVD-ROMs and possibly a license connector. The installa-
tion procedure is described in the following sections.
Online activation
This variant allows fully automatic activation if the installation
PC has direct access to the internet.
Indirect activation
In this case the PC on which FluidSIM is to be installed does not
need to have direct internet access. Instead, the subsequent
dialog window gives you an internet address and an individual-
ly generated license key. You can then generate a matching ac-
tivation code by accessing the displayed internet address from
any computer. You then enter that activation code in the field
provided in the activation dialog box on the installation PC.
Please note that this type of license transfer (without prior deacti-
vation) is only possible a few times. Moreover, when you transfer a
license to a modified or new PC, activation is no longer possible on
the original PC. Once the license is transferred, you cannot activate
FluidSIM on the original PC without a prior deactivation.
If you are using the software with a license connector, do not plug
it in until you are prompted to do so by the installation program.
Note that there are two versions of the license connector: The
newer one is silver in color and has the product label CodeMeter.
If you have purchased FluidSIM as an update of an earlier version,
you can also continue to use your existing green WibuKey con-
nector if it has been reprogrammed accordingly.
Chapter 3
3. First steps
When you start FluidSIM, the system checks whether you have
installed more than one technology (pneumatics, hydraulics, elec-
tronics). If you have, the selection window appears listing the
available technologies. Here you specify which components and
program functions you wish to use in this program session. This
decision is especially important for network users because a li-
cense will be occupied for each technology until you exit FluidSIM.
You can restart FluidSIM at any time and select a different combina-
tion.
Available technologies The available technologies and the currently free licenses are
displayed here.
Next, the key concepts and terms are described which you will
encounter when using FluidSIM.
The attribute table allows you to save any desired data in the form
of attribute value pairs. The associated placeholders (attributes
with the same name) in the drawing frame are replaced by the
values entered.
Circuits The default location for circuits is in the FluidSIM folder con-
tained in the My Documents folder defined by the operating sys-
tem. These have the circ file suffix.
The Find Symbol dialog window then opens. You can enter your
search terms in the Search input line. Separate the individual
search terms using commas or spaces. Neither the order of the
search terms nor upper or lower case letters have any influence on
the search results.
You can see the symbols found in the two results lists. The library
hierarchy is displayed on the left-hand side although only those
branches appear which contain matching symbols. An alphabetical
list of the search hits is displayed on the right-hand side. The sym-
bol of the highlighted entry is shown in the preview. Once you have
found the symbol that you were looking for, you can select it using
the &OK button or by double-clicking on the appropriate row in
the results list. The symbol then hangs on the mouse pointer and
is placed by left-clicking on the drawing area.
View Defines the size of the symbols displayed. Small , Normal and
Large are available.
The standard library This library is delivered with FluidSIM and cannot be modified.
Symbol folders Circuit and symbol files saved on the disk can be used as libraries
in FluidSIM. The files from the selected folder are added as a library
via the Library menu and the Add Existing Symbol Folder...
menu item. The library hierarchy corresponds exactly to the folder
hierarchy. These libraries cannot be modified in FluidSIM. The files
must be modified directly.
User libraries You can create and subsequently edit new libraries via the Library
menu and the Add New Library... menu item (see section Create
Paste Inserts the symbols into the library from the clipboard. These
symbols can also be partial circuits.
Rename... Edits the text which libraries display below the symbol.
Add Existing Symbols... Opens a dialog window for selecting symbol files to be copied into
the library as new symbols.
Copy to Other Library Copies the selected symbols into another library. The available
libraries are listed in a submenu. Only the currently open libraries
are displayed here (appearing as tabs in the library window) which
are not write-protects (recognizable as no lock symbol is dis-
played).
New Sub-Folder... Creates a new hierarchy level below the active group. The active
group is the one belonging to the area below the mouse point and
can be recognized by the dark blue coloring.
Remove Sub-Folder Removes the hierarchy level which the mouse pointer is located in.
FluidSIM circuit files have the circ file suffix and are saved as
compressed XML files. An option in the Save tab under the Op-
tions... menu item from the Tools menu allows you to deactivate
this compression so that the circuit files can be viewed as plain
text. This can be useful for version management software, for
example.
However, please note that editing a circ file outside FluidSIM can
cause the file to become unreadable or corrupted upon re-import.
Chapter 4
4. Library and project window
To separate the window from the anchor move the mouse pointer
to the upper margin. Click and hold the left mouse button. Move
the window a small distance towards the center of the screen. Now
release the left mouse button. Now you need to move the library
window to the lower right and the project window to the lower left.
Once a window has been separated from the anchor it can be
moved freely.
Chapter 5
5. Edit circuit
You can insert symbols into the symbol window being edited using
the dialog window Find Symbol and by means of the libraries. You
can also transfer objects from every other window by selecting
them and dragging them to the desired window. Alternatively you
can also utilize the clipboard by selecting the items, choosing the
Copy menu item on the Edit menu, bringing the target window
into the foreground and selecting the Paste menu item on the
Edit menu. Using the mouse pointer to drag objects from one
window to another copies them. Dragging the objects from one
position to another within a window moves them. In order to copy
within a window you need to hold down the Shift key while
moving the mouse pointer. You can recognize operation by the
shape of the mouse pointer. During a move-operation a cross with
arrows appears, when copying a plus symbol also appears in
the lower right-hand corner of the cross.
Now press the left mouse button and move the mouse pointer
to the connector which you wish to connect with the first.
You can recognize when you are over the connector by the shape of
the mouse pointer . If the mouse pointer is over a connector
which is already connected to a line then the prohibited sign
appears and no line can be connected.
Release the mouse button once you have touched the second
connector.
Release the mouse button once you have touched the desired
point on the line.
T distributor Defines the representation of the basic T distributor. Here you can
select whether the distributor should be represented as a filled
circle or a simple intersection.
Once you have joined two connectors you can then adjust the
length of the lines. You can move the line segments in parallel by
moving the respective line segment. You can see when you have
touched the line on the basis of the line-selection shape of the
mouse pointer.
Press the left mouse button and move the line segment or-
thogonally to the desired position.
If you only want to move the individual line segment in the case
described above then release the mouse button after you highlight
the line segment. Click the segment again and move it while keep-
ing the mouse button pressed.
You can also define the style, color and drawing layer of the lines by
double-clicking a line segment or highlighting the line segment and
selecting the Properties... menu item from the Edit menu. The
Line Properties dialog window opens. Select the Drawing Properties
tab in this window. The settings are applied to the entire line sec-
tion as far as the next connector or T distributor.
Note: Working lines are typically displayed as solid lines, pilot lines
as dashed lines.
Please note that the way the lines are displayed during the simula-
tion depends on the physical status of the lines. The colors, line
styles, and line thicknesses will vary according to pressure, flow,
Identification You can enter a text identifying this connector into the input line. If
the Display option is activated then the identification is displayed
in the circuit diagram.
Display quantity values During the simulation, the calculated quantity values can be dis-
played not only with specialized measuring devices, but also direct-
ly at the connectors. For a quick overview, you can use View
Quantity Values... to show all values at all connectors with a
single click. As this is generally fairly confusing, you can also
choose to view the quantity values at selected connectors only. For
more details, see "Displaying quantity values".
Note: Please note that this symbol list is only available if a line is
not connected to the connector in question. If you wish to connect a
If you require a certain valve which you cannot find in the standard
FluidSIM library you can create your own valve symbol with the
help of the valve editor.
To set the valve body and the actuation types of the way valves
double-click the valve. The dialog window Properties then opens.
Click the Configure Valve tab to access the valve editor.
Left Actuation Right Actua- You can select the actuation types of the valve from the Manual-
tion ly, Mechanically and Pneumatically/Electrically (Hydraulical-
ly/Electrically resp.) categories for both sides of the valve. Click
the button with the mouse pointer and select a symbol element. A
valve can have multiple actuation types at the same time. If you do
not want an actuation type from a category then select the empty
field in the list. You can also define whether each side should have
a spring return, pilot control, pneumatic spring or external supply.
Initial Position Here you set which switching position the valve should use in the
normal position. Note: When determining this setting ensure that it
does not conflict with a possible spring return.
Dominant Signal This provides a graphical identification of whether the right or left
signal should dominate in the event of equally strong signals.
External Supply This creates an additional connector for connecting the external
supply for the controller.
If you require a certain cylinder which you cannot find in the stand-
ard FluidSIM library you can create your own cylinder symbol with
the help of the cylinder editor.
Cylinder Type Click the button with the mouse pointer to open the symbol ele-
ments list. Select a cylinder type. Set whether the cylinder should
be single-acting or double-acting.
Return Spring Specifies whether a spring for the return should be inserted into the
right or left cylinder chamber.
Piston Click the button with the mouse pointer and select a symbol ele-
ment for the piston. Set whether the cylinder should possess end
position cushioning and whether this should be adjustable.
Piston Position Using the slider you can specify the relative piston position in 25 %
steps. 0 % stands for the completely retracted and 100 % extended
piston.
To align objects with each other, select these and choose the de-
sired orientation from the Align menu item on the Edit menu or
click the appropriate button on the toolbar.
You can also rotate symbols with the help of the mouse pointer by
clicking and dragging the edge of the symbol. In order to do this
FluidSIM must be in Enable Rotate mode. This mode can be
activated or deactivated using the Enable Rotate menu item from
the Edit menu or by clicking the corresponding button on the
toolbar.
In Enable Rotate mode click the edge of the symbol and hold
down the mouse button.
Hold down the mouse button and move the mouse pointer
until the desired angle of rotation is achieved. The angle
changes in 15 degree steps.
Note: If you also press the Shift key then you can rotate the
symbol steplessly.
Note that the rotation of the drawing has no effect on the simula-
tion. If you want a load to be raised, for example, you need to enter
the desired angle under Mounting angle in the component pa-
rameters.
The component symbols can be scaled with the help of the mouse
pointer. In order to do this FluidSIM must be in Enable Scale
mode. This mode can be activated or deactivated using the Enable
Scale menu item from the Edit menu or by clicking the corre-
sponding button on the toolbar.
Hold down the mouse button and move the mouse pointer
until the desired size is reached. The scaling relationship is
changed in 0.25 steps. Note: If you also press the Shift key
then you can scale the symbol steplessly.
Chapter 6
6. Drawing fra me
Texts in the title block of a drawing frame are text components. You
can use the imported texts or insert new text components at the
desired positions. Editable texts are text components with Attribute
Link. These texts are replaced by the corresponding attribute val-
ues of the project and the circuit.
All of the objects belonging to a drawing frame are inserted into the
circuit diagram as a copy. Changing the file with the drawing frame
at a later date does not have any effect on the circuit diagram which
the drawing frame was inserted into.
When copying the objects belonging to the drawing frame all of the
attributes are generated with the drawing frames text components
refer to and which do not exist in the project or circuit.
Inherit From Project If this option is activated then the drawing frame specified in the
project is copied into the circuit. The path and the file used are
displayed in the Frame File line.
Pick... This button opens a dialog window in which an included frame can
be selected. These frame files are located in the frm directory and
are compiled in the project file frames.prj.
Remove Local Frame Removes the drawing frame from the circuit. The drawing frames
attributes remain attributes of the project or circuit.
All of the available frame files are displayed as a tree on the right-
hand side. The desired drawing frame can be selected in this tree.
The drawing frame is then displayed in the preview. In addition the
Attributes list displays all of the attributes of the texts from the
drawing frame which were defined as links.
If the page dividers are visible you can customize them using the
mouse so that they match the graphical representation of the
drawing frame, for example. This customization can be done in
different ways:
Figure 6/3:
The opposite margin is not moved and the columns or rows are
resized proportionally.
Figure 6/5:
Columns and rows can be inserted and removed using the and
buttons.
The label type and the number of rows and columns can be defined
using the button. The settings are saved as page properties. The
following dialog window is opened:
Adopt from drawing frame Selecting this option only makes senses for pages that do not
represent drawing frames. This option must be deactivated if the
current page represents a drawing frame that is to be inserted into
other pages later.
If this option is activated then all settings that have been defined in
the drawing frame will be adopted.
Adopt from current paths When this option is activated, the page dividers are automatically
derived from the current paths of the electrical circuit. You can
show or hide automatic current path numbering via the Display
Current Path Numbering menu.
Chapter 7
7. Additional tools for creating dr awings
7.1.1 Grid
For arranging the symbols and laying the lines it is often practical to
show a point or line grid. You can activate or deactivate the display
of the grid using the Show Grid menu item from the View menu.
You can also define further grid settings in the General tab under
the Options... menu item from the Tools menu.
Note: The grid snap function may not be desired as it prevents free
positioning. In this case you can hold down the Ctrl key during
the moving operation; this temporarily deactivates the grid snap
function.
FluidSIM supports the exact positions firstly via the grid snap and
secondly via automatically displaying red alignment lines while
moving the selected objects.
Observe the dashed red lines which appear when two or more
connectors lie above each other.
Note: The grid snap function may not be desired as it prevents free
positioning. In this case you can hold down the Ctrl key during
the moving operation; this temporarily deactivates the alignment
lines and the grid snap function.
Snap to Grid
Snap to Connector
Snap to Centre
Snap to Intersection
Press and hold the Ctrl key during a drawing operation to tempo-
rarily deactivate the object snap function.
7.1.4 Rulers
The rulers can be shown and hidden via View Show Rulers .
They are displayed at the left-hand as well as the upper edge of the
circuit window.
To be able to use the rulers, you need to activate the Expert Mode
option in the Options... menu.
You can select the drawing layer where newly inserted objects
should be placed under Default Layer . If you do not want the
symbol layer to be changed when objects are inserted then select
the Preserve Object Layer option.
7.3 Cross-references
The option also exists to reference any object within a project from
a cross-reference symbol. The cross-reference is uni-directional in
this case: from the cross-reference to the target object. This allows
several cross-references to reference the same object.
Open the Cross-reference dialog window from the Edit menu and
the Properties... menu item. Alternatively you can open this
dialog window by double-clicking the cross-reference symbol or
using the Properties... context menu.
Label Defines the labels via which the linked cross-references are identi-
fied.
Link If this option is activated then the label entered constitutes a link to
a target object. The cross-reference only works in the direction of
the target object in this case. This option can be combined with the
Show Location option to show the location of the target object.
Target Text If the Show Location option is activated then the location of the
target object will be displayed here. The representation of the
location is defined in the Cross Reference Representation tab in the
properties dialog window for the page or project.
Display Target Text If this option is activated then the above-mentioned text from the
Target Text field is displayed below the text for this cross-reference.
Jump to Target Activating this button opens the circuit window containing the
corresponding cross-reference. The associated symbol is indicated
by an animation.
The font type, text color and alignment of the texts to be displayed
can also be customized.
Inherit From Parent Node Defines whether the representation rules for the parent node
should be applied.
Jump to Target Using this button you can jump to the corresponding cross-
reference.
Switches to the mode for drawing a conduction line. You can start
by choosing whether you would like to draw a pneumatic, hydrau-
lic, electric, digital, or GRAFCET conduction line.
7.4.1 Interruption/Potential
If conduction lines extend over several pages then the line ends can
be assigned interruptions. Interruptions can be used to define that
a conduction line is only interrupted in the drawing and is contin-
ued somewhere else. An interruption can be assigned an identifica-
tion and linked with another interruption. The location of the linked
interruption can be displayed at the source interruption.
A dialog window opens where you can make various settings for
the interruption to be inserted.
Define multiple connectors Multiple interruptions can be set one after the other if this option is
active. You can cancel the action by pressing the Esc key.
Identification Defines the identification for the interruption. The identification will
be displayed in the circuit if the Display option is active.
Jump to Target If the interruption is linked with another interruption then this
button can be used to jump to the counterpart interruption.
Show Location If this option is activated and the interruption is linked with another
interruption then the location of the counterpart interruption will be
displayed as a page coordinate (e.g. page number/column).
You open a dialog window where you can make various settings for
the line to be dragged using the Insert Conduction Line... menu
item or the button on the toolbar.
Type of connection line Selects the conduction line type. The following are available:
Pneumatic and Electric.
Define multiple lines Multiple conduction lines can be set one after the other if this
option is active. You can cancel the action by pressing the Esc
key.
7.4.3 Line
Background Sets the location of the drawing element to the background. This
means that all of the circuit symbols are on top of this. For example
symbols are not covered by filled drawing elements.
Background Sets the location of the drawing element to the background. This
means that all of the circuit symbols are on top of this. In particular
it means that symbols are not covered by filled drawing elements,
for example.
Foreground Sets the location of the drawing element to the foreground. This
means that all of the circuit symbols are underneath this. In particu-
lar it means that symbols are covered by filled drawing elements,
for example.
You can move the existing vertices by clicking and dragging. The
mouse pointer changes to when you mouse over an existing
vertex. If the mouse pointer is over a line without a vertex is
displayed and a new vertex is inserted as soon as you click.
7.4.5 Rectangle
Background Sets the location of the drawing element to the background. This
means that all of the circuit symbols are on top of this. For example
symbols are not covered by filled drawing elements.
Foreground Sets the location of the drawing element to the foreground. This
means that all of the circuit symbols are underneath this. For ex-
ample symbols are covered by filled drawing elements.
Background Sets the location of the drawing element to the background. This
means that all of the circuit symbols are on top of this. For example
symbols are not covered by filled drawing elements.
Foreground Sets the location of the drawing element to the foreground. This
means that all of the circuit symbols are underneath this. For ex-
ample symbols are covered by filled drawing elements.
7.4.7 Ellipse
Background Sets the location of the drawing element to the background. This
means that all of the circuit symbols are on top of this. For example
symbols are not covered by filled drawing elements.
7.4.8 Text
7.4.9 Image
Background Sets the location of the drawing element to the background. This
means that all of the circuit symbols are on top of this. For example
symbols are not covered by filled drawing elements.
Foreground Sets the location of the drawing element to the foreground. This
means that all of the circuit symbols are underneath this. For ex-
ample symbols are covered by filled drawing elements.
External Link When this option is active FluidSIM only saves a link to the image
file. However if this option is deactivated then the image is embed-
ded in the circuit diagram. This is the preferable variant if you wish
to pass on or archive the circuit diagram.
You can use Check Drawing in the Page menu to have FluidSIM
check your drawing for possible drawing errors. FluidSIM displays
the following messages where necessary:
Superimposed objects
Open connectors
Superimposed lines
Missing translations
Unassigned cables
Unassigned terminals
Chapter 8
8. Simulating with FluidSI M
You can find these sample circuits under Circuits for exercises
(TP)... in the Didactics menu. The names of the folders match
those of the corresponding workbooks from Festo Didactic GmbH &
Co. KG. The sample circuits can be edited and simulated as desired.
However, bear in mind that your modifications may alter the func-
tion of the circuit and consequently also the training material. We
therefore recommend saving any modified sample circuits under a
different name or in their own folder.
Open the circuit demo1 and start the simulation via Execute
Start or using the symbol .
The calculation of the quantity values also forms the basis for the
exact, real-time-proportional animation of the cylinders.
When you switch from Simulation Mode to Edit Mode, the non-
adjustable components are automatically reset to their normal
state. In other words, the switches are set to their initial position,
the valves switch to their normal position, the cylinder pistons are
set to the position previously set for them, and all calculated quan-
tity values are deleted. Components used to adjust or harmonize
the system on the other hand, such as flow control valves, pres-
sure-reducing valves or potentiometers, retain the values set by the
user during the simulation.
In single step mode, the simulation will stop after a small step.
More exactly, clicking or Execute Single Step starts the
simulation for a short period of time (about 0.01-0.1 seconds of
simulation time in the real system) before switching back into
pause mode ( ).
You can switch into single step mode directly from an actively
running simulation. This makes it easy to focus on key moments in
the simulation.
4. A switch is actuated
This section assumes that you are already familiar with the basic
concepts involved in creating circuits. If necessary, read the section
Create a new circuit drawing" first.
To define the valves actuation type, double click the valve. The
valves property dialog opens.
If required, you can also set the standard nominal flow rate of the
valve.
Close the dialog box with &OK . As port 3 on the valve is only
needed as an air outlet, set a silencer there.
Select the third symbol (the simple silencer) and close the
dialog box.
Move the mouse pointer onto the valve and click the valve with
the pointing finger .
Once the cylinder has advanced, the pressure in the cylinder supply
line must inevitably increase. This situation is detected by FluidSIM
and the parameters are recalculated; the pressure at the com-
pressed air supply increases to the set operating pressure.
Drag another 3/n-way valve onto the drawing area and open
the valve configuration dialog box by double clicking (or by
Edit Properties... ). Construct a pneumatic valve (normally
closed), close the dialog box, put a silencer on port 3 again,
and arrange the components as follows:
Draw a line from the outlet port of the manually operated valve
to the control port of the pneumatic valve.
Save this circuit with (or with File Save File ). FluidSIM
automatically opens the file selection box if the file did not al-
ready exist; you can enter a file name in that box.
When you click a valve, the real behavior of the valve is simulated.
In our example, the clicked valve is switched over and recalculation
begins automatically. As a result, the indirectly activated pneumatic
valve is switched and the cylinder advances.
100 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
The following figure shows a 3/2-way valve in closed position and
in open position:
Stop the simulation and switch to Edit Mode. Select the state
diagram from the component library and move it into the circuit
window.
The state diagram records the quantity values for the most im-
portant components and displays them in graph form.
A dialog box opens where you can select the quantity values you
are interested in. In this instance, only the position is of interest, so
you can remove the check marks for the other values (velocity,
acceleration).
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 101
Figure 8/7: Circuit with state diagram for the cylinder
If the mouse pointer rests on the diagram for a second, a box ap-
pears showing the exact values for time and the relevant quantity
value. If you move the mouse along the curve, the display alters
accordingly, updating the values as the mouse pointer moves.
102 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 8/8: Display of the exact values in the state diagram
You can use multiple state diagrams in one window, and can also
display multiple components in the same diagram. You can add a
component to a state diagram by dragging it onto the diagram. A
dialog will open, where you can select the quantity values to be
logged and can assign different colors to them. Dragging onto the
diagram again opens the dialog box again, allowing you to change
your selection. If no quantity value is assigned to a component, it is
not displayed in the diagram.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 103
Figure 8/9: Simple hydraulic circuit
To define the valves actuation type, double click the valve. valves
property dialog opens.
If required, you can also set the hydraulic resistance of the valve.
104 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 8/10: Manually operated 4/2-way valve
Then all pressures and flow rates are calculated, the lines are
colored, and the cylinder advances:
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 105
Figure 8/11: Simulated circuit
Once the cylinder has advanced, the pressure in the cylinder supply
line should increase. This situation is detected by FluidSIM and the
parameters are recalculated; the pressure on the pump side in-
creases to the value predefined by the limit protection in the pump
unit.
106 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Drag a pressure relief valve and a second tank onto the draw-
ing area.
Save this circuit with (or with File Save File ). FluidSIM
automatically opens the file selection box if the file did not al-
ready exist; you can enter a file name here.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 107
The cylinder advances. Once it reaches its stop, a new situation is
created. This situation is detected by FluidSIM and the parameters
are recalculated; the pressure relief valve opens, and the resulting
distribution of pressure is shown:
108 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 8/14: Closed and open pressure relief valve
Move the mouse pointer onto the left-hand side of the direc-
tional control valve.
Click the left-hand side of the valve and hold down the mouse
button.
When you click a valve with the mouse, the real behavior of the
valve is simulated. In our example, the clicked valve is switched
over and recalculation begins automatically. As a result, the pres-
sure relief valve closes and the cylinder retracts. As soon as the
cylinder reaches its left-hand stop, the pressure relief valve opens
again.
Stop the simulation and switch to Edit Mode. Select the state
diagram from the component library and move it into the circuit
window.
The state diagram records the quantity values for the most im-
portant components and displays them in graph form.
A dialog box opens where you can select the quantity values you
are interested in. In this instance, only the position is of interest, so
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 109
you can remove the check marks for the other values (velocity,
acceleration).
If the mouse pointer rests on the diagram for a second, a box ap-
pears showing the exact values for time and the relevant quantity
value. If you move the mouse along the curve, the display alters
accordingly, updating the values as the mouse pointer moves.
110 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 8/16: Display of the exact values in the state diagram
You can use multiple state diagrams in one window, and can also
display multiple components in the same diagram. You can add a
component to a state diagram by dragging it onto the diagram. A
dialog will open, where you can select the quantity values to be
logged and can assign different colors to them. Dragging onto the
diagram again opens the dialog box again, allowing you to change
your selection. If no quantity value is assigned to a component, it is
not displayed in the diagram.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 111
Figure 8/17: Simple electronic circuit
Then all voltages and currents are calculated, and the potential
from the positive terminal of the electrical power source to the
pushbutton is colored.
The current now flows through the pushbutton to the ground via
the ammeter and the light:
112 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 8/18: Simulated circuit
The values for current and voltage can be read on the measuring
devices. So far, the circuit is a purely electric circuit, strictly speak-
ing. Now lets add an electronic component: the diode.
Stop the simulation and switch to Edit Mode. Modify the circuit
as shown in the figure and start the simulation.
Ensure that the diode is installed as shown. When you actuate the
pushbutton, you will see that the potential only reaches as far as
the diode:
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 113
Figure 8/19: Diode installed in reverse direction
114 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 8/20: Warning of error in line layout
Once the diode is installed correctly, the current will flow through
the diode and the light will light up:
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 115
Figure 8/21: Diode installed in forward direction
Stop the simulation and switch to Edit Mode. Modify the circuit
as shown.
116 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 8/22: Simple circuit with a potentiometer
Stop the simulation and switch to Edit Mode. Select the state
diagram from the component library and move it into the circuit
window.
The state diagram records the quantity values for the most im-
portant components and displays them in graph form.
A dialog box opens where you can select the quantity values you
are interested in. In this instance, only the amperage is of interest.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 117
Start the simulation, vary the resistance value of the potenti-
ometer, and observe the diagram.
If you move the mouse along the curve, the display alters accord-
ingly, updating the values as the mouse pointer moves. If you move
118 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
the mouse along the curve, the display alters accordingly, updating
the values as the mouse pointer moves.
You can use multiple state diagrams in one window, and can also
display multiple components in the same diagram. You can add a
component to a state diagram by dragging it onto the diagram. A
dialog will open, where you can select the quantity values to be
logged and can assign different colors to them. Dragging onto the
diagram again opens the dialog box again, allowing you to change
your selection. If no quantity value is assigned to a component, it is
not displayed in the diagram.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 119
Advanced concepts in simulating and creating circuits
Chapter 9
9. Advanced concepts in simulating and creating circuits
120 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 9/1: Adjustable parameters of the one-way flow control
valve
Show designation Shows the designations of the parameters displayed using the
Display option.
Show variable Shows the variables of the parameters displayed using the Display
option.
Show Unit Shows the units of measurement of the parameters displayed using
the Display option.
Display Check this box if you want that parameter to be displayed in the
circuit.
Variable Clicking this button takes you to a dialog box with assignment
options for accessing the parameter in GRAFCETs or for controlling
it with a game controller.
In the Opening level row, click the button for variable assign-
ment.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 121
Figure 9/2: Variable and controller assignment of a parameter
Predefined variable This is the standard, complete variable name. It is made up of the
identification entered by you and the internal parameter name. You
can use this variable name to access the parameter in GRAFCETs in
order to query it or modify its value.
User-defined alias If you do not like the predefined variable name, you can enter your
own name for it here. Note that this alias has to be unique across
the entire page or project. FluidSIM issues a warning if an alias
name is entered twice.
122 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Controller assignment As described in the "Adjusting component parameters during the
simulation" section, many component parameters can be altered
with the mouse during the simulation. FluidSIM also offers the
option of controlling parameters via connected game controllers
(e.g. Microsoft Xbox controller). This is especially practical when
you need to modify several parameters at the same time during a
simulation.
Axis Here you can define which axis you want to use to control the
parameter during the simulation. To assign an axis, simply click in
the field and briefly actuate the desired controller axis. FluidSIM
then enters the desired axis.
Dead-zone This value determines how much movement of the controller axis is
required to trigger a signal. This prevents unintended modification
of values from very small movements of the fingers.
Range Sometimes you may wish to use the game controller to control only
a certain range. This can be necessary above all because the con-
trol levers on most controllers spring back to their zero position
automatically as soon as they are released. Using the mouse to-
gether with the straight line on the graph, you can interactively
determine how the controller position relates to the parameter.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 123
Figure 9/3: Variable assignment of a simulation parameter
If the options Show all settings and Enter manually are select-
ed, you can specify parameters defining a velocity-dependent
characteristic curve and the mass moved by the cylinder. If you
select Calculate automatically, an heuristic is applied which
calculates the settings on the basis of the cylinder dimensions.
124 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 9/4: Friction curve of a pneumatic cylinder
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 125
Figure 9/5: External load on the cylinder
Moving mass Enter here the mass of the load that you want the cylinder to move.
The mass of the cylinder piston and piston rod is calculated auto-
matically by FluidSIM from the entered cylinder dimensions, so the
mass entered here refers only to the external load. In particular, an
entry of 0 does not mean that the moving parts in the cylinder
have no mass.
Friction The static friction and sliding friction define the friction of the
moving load on a surface. The internal friction in the cylinder is
calculated automatically by FluidSIM from the entered cylinder
dimensions. If the load is lifted or pulled without coming into con-
126 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
tact with a surface, enter 0 for both values. In practice it is very
difficult to arrive at reliable values for friction. FluidSIM therefore
offers set friction coefficients for some combinations of materials,
to provide a rough guide. If you compare other tables of friction
values, you will notice that the specifications (usually measured in
experiments) vary greatly from table to table. You should therefore
be cautious when interpreting the results of simulations influenced
by friction. Nonetheless, varying the friction values does allow you
to see clearly the physical effects of static and sliding friction. Note
also that the mounting angle influences the friction force from the
moved load. You can adjust the mounting angle on the Component
Parameters tab.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 127
9.2.3 Force profile
Constant force If you want a constant force to be applied over the entire range of
cylinder movement, select this option and enter a force.
Apply force profile Select this option if you want the force to change depending on the
cylinders position. By clicking the mouse in the graph field, you
can interactively set reference points which will be interpolated to
form a line. Alternatively, you can select an existing reference point
128 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
and numerically enter the two values in the input fields for the
piston position and the corresponding force.
You can use the sliders to adjust the displayed value ranges for
position and force. As the force on the y-axis covers an especially
wide numerical range, it is advisable to start by restricting that
interval so that the shape of the curve can be seen clearly.
Retraction = Extraction Select this option if you want to apply the same force profile for
advancing and retraction. Otherwise, remove the checkmark and
enter separate force profiles on the tabs Extraction and Retrac-
tion.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 129
9.2.4 Actuating labels
Here you can create new actuating labels or modify existing ones.
This dialog box is identical to the one that opens when you double
click an distance rule.
Displacement encoder In addition to the actuating labels you can also enter a special label
for a continuous displacement encoder or select from the list of
counterparts already present in the project.
130 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
9.3 Special settings for directional control valves
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 131
Figure 9/8: Hydraulic resistance curve
132 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
9.4.1 Simultaneous actuation of several components
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 133
currently active circuit window. In such cases, it is therefore possi-
ble to simulate one circuit while editing another.
The numerical values for all or some quantity values in a circuit can
be displayed even without measuring devices.
134 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 9/9: Dialog box for adjusting the quantity values display
Here you can define how every quantity value listed (Velocity,
Pressure, etc.) will be displayed.
For the display of pressure values, flow rates, and forces, you can
choose between different units of measurement. These settings
take effect when quantity values are displayed at connectors and
components and on state diagrams.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 135
All Display all values for this quantity value.
Display measurement units Activate this option if you also want the unit of measurement to be
displayed for the quantity values.
You can use the key in the Shortcut column to switch between
the display types None , Individual and All for that
particular quantity value without having to open the dialog box.
Open a circuit.
The dialog box for the connectors settings then opens. In the
Display quantity values field, you can choose which quantity
values are to be displayed at that connector when the Individual
option is activated for that parameter in the dialog box for quanti-
ty values display.
136 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
9.6 Displaying state diagrams
The state diagram records the quantity values for the most im-
portant components and displays them in graph form. Quantity
values or output variables all those values calculated by FluidSIM
during the simulation or set by the user, such as: position, velocity,
acceleration, force, switching position, pressure, flow rate, opening
level, revolutions/rpm, voltage, current, digital state, etc.
You can use multiple state diagrams in one window, and can also
display multiple components in the same diagram. You can add a
component to a state diagram by dragging it onto the diagram. A
selection dialog box will open, where you can select the quantity
values to be logged and can assign different colors to them. Drag-
ging onto the diagram again opens the dialog box again, allowing
you to change your selection.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 137
Figure 9/10: Dialog box for the state diagram
Display interval Here you can enter the start and end times of the interval during
which you want the quantity values to be logged. You do not nec-
essarily need to know before starting the simulation the times at
which the important events will occur; you can always change the
display interval as desired after the simulation because FluidSIM
always logs all values internally for the entire simulation period. If
you select the Adjust automatically field, the entered limits are
ignored and the time axis is scaled so that the entire simulation
time is displayed. Activate the Scroll automatically field if you
want the diagram to display the last n seconds. In this case, the
time axis will be displaced toward the left-hand side once the
simulation period exceeds the defined time window. In the input
field, you can specify the number of seconds to be displayed in the
time window.
Diagram columns Here you can select which columns you want to be displayed at the
left-hand side of the diagram. You can choose the columns De-
scription, Identification, and Quantity value in any combina-
tion.
138 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Log file If you wish, FluidSIM can create a log file of the quantity values.
Activate this option by entering the full path for the file in the input
field and select a suitable time increment. Please note that entering
very small increments may result in a very large volume of data.
You may need to reduce the simulation time or increase the time
increment.
Fill Area Defines whether the entire area is filled with the chosen color or
just the border of the diagram.
Layer In this drop-down list, you define the Layer of the diagram. You can
set the Layer by clicking the downward-pointing arrow to the right
of the list and selecting a layer. Depending on the setting for draw-
ing layers, the rectangle might not be displayed or might not be
able to be edited. In order to see the object or change its settings,
you have to temporarily activate the drawing layers with menu item
View Drawing Layers... .
Quantity values This list contains all the quantity values displayed in the diagram.
Every component is listed together with its identification, and all its
output variables are listed below it. Every variable can be selected
and deselected with a checkmark. Once you have marked a varia-
ble, you can use the buttons at lower right to define the color, line
style, and line thickness for it. You can use Add to select the
components you want. Delete deletes the marked component
together with its quantity values, and Find Target... takes you to
the relevant component in the circuit.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 139
and interchanged across all FluidSIM versions and can be combined
with the electronic components in FluidSIM-E.
Start the simulation and observe that the indicator light lights
up.
140 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
A label has a specific name and can be assigned to a component. If
two components have labels with the same name, they are con-
nected even if there is no visible line drawn between them.
You can enter the name for a label in a dialog box which you open
either by double clicking the component or by selecting the compo-
nent and clicking Edit Properties... . With electrically operated
valves (solenoid actuated), the labels are entered on the left and
the right by double clicking the appropriate connector, as op-
posed to clicking in the middle of the component.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 141
Figure 9/12: Simple electro-pneumatic circuit
Double click the valve solenoid or select the solenoid and click
Edit Properties... .
142 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 9/13: Dialog box for the valve solenoid
Identification This text field is for entering a label name. A label name can be up
to 32 characters long and can contain numerals and special charac-
ters as well as letters.
Enter the same label name there as for the solenoid (Y1).
In reality, the valve solenoid would not be activated directly via the
switch but via an intermediate relay. This is left out here for the
sake of simplicity.
The electrical current and the pressure and flow distribution are
calculated, and the resulting pressures are shown in color.
If you want to view the exact values for the quantity values, you can
activate them in the dialog box accessible via View Quantity
Values... . The activated quantity values are shown at the compo-
nent connection points. For more detailed information about this,
see "Displaying quantity values".
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 143
Operate the electrical switch.
144 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 9/15: Valve with mechanical actuation
A dialog box will open in which you can enter a label. If you enter
the same label on the cylinders distance rule, the valve will be
actuated mechanically when the cylinders piston rod reaches the
specified position.
A dialog box will open in which you can adjust the cylinders prop-
erties. Go to the Actuating labels tab.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 145
Figure 9/16: Cylinder configuration dialog box
146 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 9/17: Linking the displacement encoder to the cylinder
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 147
Figure 9/18: Dialog box for setting the text frame
Under Text Attributes you can set the option Frame Text.
If you have inadvertently moved a label text so far that you cannot
tell which component it belongs to, you can double click the label
to open the properties dialog box and then activate the associated
component with Find Target... .
148 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
9.8.1 Switches at cylinders
Drag the cylinder onto the drawing area and open its proper-
ties by double clicking. Go to the Actuating labels tab and en-
ter a label along with the start and end positions.
When you close the dialog box, the distance rule will appear auto-
matically above the cylinder. You can move or copy the distance
rule from one cylinder to another. When the distance rule comes
close to a cylinder, it slots automatically into the correct position.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 149
Figure 9/20: Dialog box for the distance rule
Label The text fields in the left-hand column are used to enter the label
names of proximity switches or limit switches in the electrical
circuit that you want the cylinder piston to actuate.
Position The text fields in the right-hand columns define the exact start and
end positions of the switches on the cylinder.
Enter Y1 as the label in the first row and enter 35 for both
the start and end positions, and close the dialog box by clicking
&OK .
A dash with the label name will appear immediately at the corre-
sponding position under the distance rule:
This means that this cylinder will activate the switch or valve la-
beled Y1 once its piston has moved 35 mm, assuming that the
same label was entered on the switch in the electrical part of the
circuit or on the mechanical connector of the valve.
150 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Once the cylinder in the above example passes the 35 mm position,
the switch will drop out again. If you want the actuation to be
maintained over a longer distance, enter the start and end posi-
tions accordingly in the dialog box.
9.8.2 Relays
In addition to the simple relay, there are also relays with switch-on
delay, relays with switch-off delay, and counting relays. They en-
sure that the linked switches are not actuated until a defined time
or number of pulses is reached. With these relays too, double
clicking will open the corresponding dialog boxes for entering the
values.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 151
9.8.3 Coupling mechanical switches
152 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 9/23: Dialog box for general electrical switches
This means that special symbols do not need to be used for these
switches in FluidSIM. The simple switch symbols can be used
instead:
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 153
You can open the dialog box for adjusting the parameters by dou-
ble clicking or with Edit Properties... .
154 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
9.10 Settings for simulation
Note that these settings are only used if no others are defined in
the page or project properties. Newly created pages and projects
are preset with the standard values set under Options... .
The EasyPort hardware can also be addressed using DDE and OPC
communication. This allows you to control even remote EasyPort
modules that are not connected locally (e.g. via a network connec-
tion). However, if the EasyPort modules are connected directly to
the simulating PC, it is recommended to set up the direct connec-
tion.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 155
Figure 9/26: Dialog box for the EasyPort components
Direct EasyPort connection Here you can set the serial port by which the hardware is connected
to the PC, which EasyPort module and port number is assigned to
the input/output component. If you do not know the exact number
of the serial port, leave the setting as Automatically. FluidSIM
then searches all COM ports for connected EasyPorts.
Older EasyPorts are fitted as standard with only a serial port, of the
kind used for many years on PCs and also in industrial applications.
Modern PCs and especially portable computers, however, increas-
ingly do not feature this connection. Nonetheless the serial port
interface can be retrofitted easily using an inexpensive USB-to-
serial converter, allowing the EasyPort to be connected and operat-
ed anyway. The converters software does this by setting up a
virtual COM port, which is assigned a number higher than the
physically existing ports (usually COM 5). The hardware can be
addressed in the usual way via this virtual port.
Connector color Defines the color of the connection indicators for the input/output
component when the EasyPort connection is active and when the
connection is not present or is disrupted.
Voltage range With the analog interface components, you can select the voltage
range. This can be either from 0V to 10V or from -10V to 10V.
156 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
If FluidSIM does not find any EasyPort hardware at the start of the
simulation, a corresponding warning is issued. You can start the
simulation anyway, but if you do so FluidSIM will not make any
further attempts to find EasyPorts until the simulation is closed and
restarted. If, on the other hand, the connection is terminated while
the simulation is running (e.g. by inadvertently pulling out the
connecting cable), the simulation will continue to run without the
EasyPort link, but FluidSIM will attempt to restore the connection.
As soon as the hardware is once again available at the set port, the
connection is restored and the simulation continues with EasyPort
communication.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 157
Figure 9/27: Dialog box for the OPC components
OPC server Enter the OPC server here or press the Pick... button and select it
from the list.
Item Enter the data item here or press the Pick... button and select it
from the list.
158 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 9/28: Dialog box for the DDE components
Server This is the server name that FluidSIM uses when it registers in the
system as a DDE server. As the server name is a global setting, it
cannot be changed directly in this dialog box. Pressing the Global
DDE server name... button takes you to the options dialog box
where you can change the server name for the entire system.
Topic Here, enter the topic via which you would like to address the
components.
Label Here, enter the label or the item via which you would like to
address the components.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 159
directional control valves, these components are controlled via a
proportional amplifier or via a valve solenoid. These valves, howev-
er, are represented by special symbols:
The term closed-loop control is used when the output variable (or
a quantity value affected by it) is used in turn as the input variable.
It is also quite possible for multiple output variables (and quantity
values dependent on them) to be combined together with addition-
al input variables, using a calculation rule. A classic example is
position control, where a cylinder needs to move to a certain posi-
160 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
tion. The valve is activated electrically so that the cylinder moves.
The cylinders position (resulting from the movement caused by the
valve setting) is used in turn as an input variable, to determine the
deviation between the cylinders position and its setpoint position.
Once the cylinder has reached its target position, the deviation is 0
and the valve returns to its mid-position (closed position). The
cylinder thus comes to a halt. If inertia or external disruption caus-
es the cylinder to move past its target, the valve switches over to
the other side, reversing the flow direction, and the cylinder moves
back. This is the simplest form of closed-loop control, known as P
control (proportional control).
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 161
valve solenoid, so that the valve connected to it is shifted to either
side to the maximum extent according to the signal voltage applied.
The voltage will now vary between 3 and 7 volts. As a result, the
valve will still shift symmetrically, but with less displacement from
the mid-position.
162 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
The sliders of the function generator for Frequency and Ampli-
tude have no function when the signal type is set to Constant.
This allows us to use it to simulate a manually adjustable potenti-
ometer.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 163
Figure 9/33: Simple open-loop control of the regulating valve
164 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 9/34: Properties dialog box for the function generator
The voltage will now vary between -4 and 4 volts. As a result, the
valve will still shift symmetrically, but with less displacement from
the mid-position.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 165
Start the simulation and click the function generator (with a
single click).
166 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 9/36: Simple closed-loop position control
Start the simulation and observe that the cylinder stops once it
has traveled half the distance.
Now we want to expand the circuit so that the cylinder can move to
any position we set on a slider during the simulation, as quickly as
possible but still accurately. This is done using a PID controller.
Construct the following circuit and set the parameter values for
the PID controller as shown.
Note that the regulating valve is mirrored from its position in the
example above.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 167
Figure 9/37: Position control with PID controller
Start the simulation and slowly move the y offset of the func-
tion generator between 0 and 10.
168 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
the cylinder pistons mid-position. It does not matter what position
the cylinder starts from; it will always stop at the specified target
position.
Vary the initial piston position and observe how the cylinder
reaches its setpoint position every time without fail.
Pneumatics are fast. So you can more clearly observe the effects
described below, set the stroke of the cylinder to 5000 mm.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 169
Figure 9/38: Position displacement and change in velocity during
closed-loop control
170 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 9/39: Position displacement and change in velocity with
amplified input signal
You can see clearly that the cylinder now moves at a constant
velocity for a long distance. It then brakes sharply and comes finally
to a stop.
However, you can see that the cylinder piston moves clearly beyond
its target, due to its inertia and the compressibility of the air, and
moves back and forth several times before finally coming to rest.
These oscillations around the setpoint position are typical for this
kind of simple closed-loop control. In practice, you would try to
reduce these oscillations by tweaking the parameters of the PID or
loop controller. However, at this stage we will stop at the simple
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 171
basic principles, and refer you to the literature on proportional and
closed-loop systems for further reading.
Start the simulation and observe how the cylinder retracts and
the valve moves further and further into its closed position.
This makes the cylinder slower and slower until it is fully retracted.
Strictly speaking this is not really position control, because the
cylinder would have stopped when it reached its physical stop
anyway. So now lets change the relationship in the displacement
encoder between the piston position and the output voltage. For
example, if we want the cylinder to stop in the middle, the valve
172 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
must be in its closed position at the exact time when the cylinder
reaches that position. As the output voltage is proportional to the
piston position, it is easy to calculate how the voltages at the two
limits (cylinder retracted/cylinder advanced) need to be selected in
order for the voltage to be 0 V halfway through the cylinder stroke:
Start the simulation and observe that the cylinder stops once it
has traveled half the distance.
Now we want to expand the circuit so that the cylinder can move to
any position we set on a slider during the simulation, as quickly as
possible but still accurately. This is done using a PID controller.
Construct the following circuit and set the parameter values for
the PID controller as shown.
Note that the pump unit and the tank are mirrored from their posi-
tions in the example above.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 173
Figure 9/42: Position control with PID controller
Start the simulation and slowly move the y offset of the func-
tion generator between -10 and 10.
174 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
ed and 10 V meaning fully advanced. The value 0 thus repre-
sents the cylinder pistons mid-position. It does not matter what
position the cylinder starts from; it will always stop at the specified
target position.
Vary the initial piston position and observe how the cylinder
reaches its setpoint position every time without fail.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 175
Figure 9/43: Position displacement and change in velocity during
closed-loop control
176 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Set the Proportional gain of the PID controller to 10 and start
the simulation.
You can see clearly that the cylinder now moves at a constant
velocity for a long distance. It then brakes sharply and comes
quickly to a stop.
If the cylinder had to move a load, its inertia would cause it to move
slightly beyond its target and it would have to move back and forth
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 177
several times before coming to rest. These oscillations around the
setpoint position are typical for this kind of simple closed-loop
control. In practice, you would try to reduce these oscillations by
tweaking the parameters of the PID or loop controller. However, at
this stage we will stop at the simple basic principles, and refer you
to the literature on proportional and closed-loop systems for fur-
ther reading.
Set the function generator to the sine function and the fre-
quency to 1 kHz. Now start the simulation and click the oscillo-
scope.
178 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 9/46: Modeling of a real oscilloscope
Turn the various dials and observe how the displayed curve
changes.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 179
9.15 Simulation of rotating machines
But things are not that simple in the case of machines with more
complex designs such as asynchronous AC motors, capacitor mo-
tors and synchronous motors. Here its much more difficult to arrive
at the characteristic parameters on the basis of the machines
specified performance data. The physical relationships which are
taken advantage of in order to generate rotary motion in these
180 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
motors are so complex, that the machines inner values cannot be
calculated directly from the nominal values.
The fact that the inner values can only be approximated and not
precisely calculated results in the following effects in the simula-
tion:
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 181
rameters based on the user entries, a similar machine is calcu-
lated which corresponds at least to the most important attrib-
utes. If this works, the symbol is identified in gray in order to
indicate that not all of the entries have been used. The parame-
ters which could not be taken into consideration are displayed
in the components characteristics dialog box. The affected en-
try fields are identified there in color.
182 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
GRAFCET
Chapter 10
10. GRAFCET
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 183
10.1.1 Drawing only (GrafEdit)
184 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
ments, but also permitting the GRAFCET actions to actively modify
the values of those elements. This means GRAFCET cannot only
take the place of an additional control, but can also initiate user
actions. For example, pressing a pushbutton or switching over a
manually operated valve can be simulated. This opens up a wide
range of control possibilities because the GRAFCET can query all
component parameters and also modify them when required. This
includes the initiation of switching operations, the adjustment of
flow control valves, and the modification of electrical resistances.
Like the other simulation settings, the GRAFCET mode can be set for
a single page, for an entire project node, and also in the global
settings. For example, you can set the global GRAFCET settings
under Tools Options... , GRAFCET tab and you can set the page-
specific GRAFCET settings under Page Properties... , GRAFCET
tab.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 185
10.3.1 Steps
Steps are either active or inactive and can be linked by actions. The
actions of active steps are executed. The sequence of a GRAFCET is
described by the transitions from a previous to a subsequent step.
Steps and transitions have to alternate in the plan.
Each step has to be assigned a name. All newly created steps are
consecutively numbered automatically. If a step is to be active at
the start of the sequence control, it is marked as the initial step.
186 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 10/2: Step
Active steps are marked with a point. Additionally, active steps are
framed in green.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 187
10.3.2 Actions
For a stored effective action, the set value of the variable remains
unchanged until it is changed by another action. This way of setting
a variable is referred to as allocation in the GRAFCET specifica-
tions.
At the start of a sequence, all the variable values are initialized with
0.
188 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Create the following GRAFCET. Select the action Simple ac-
tion in the properties dialogue and enter A under Varia-
ble/output. Then start the simulation.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 189
10.3.3 Transitions
t1 s / term / t2 s
190 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
The transition condition becomes true (1) t1 seconds after term
has changed its value from 0 to 1. This is called a rising edge.
The transition condition becomes false again (0) t2 seconds after
term has changed its value from 1 to 0. This is called a fall-
ing edge.
The short form t1 s / term is also allowed. The system then as-
sumes that t2 is 0 seconds.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 191
Figure 10/9: Transition dialog window
192 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 10/11: GRAFCET cycle
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 193
Figure 10/12: GRAFCET
194 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 10/14: GRAFCET-PLC component
You can open the properties dialog box by double clicking. You can
access the adjustable parameters on the Component Parameters
tab.
Related pages The GRAFCET plans on the specified pages will be assigned to the
GRAFCET-PLC component. If you do not specify any related pages,
the GRAFCET assigned will be the one on the same page as the
GRAFCET-PLC component.
Inputs This list defines the names of the input variables that can be evalu-
ated by the conditions of the related GRAFCET. Specifying a name is
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 195
optional. The input variable names I0 to I7 are created auto-
matically. The value of an input variables is set to 1 when a
voltage of at least 24 volts is applied to the corresponding electrical
connection and the GRAFCET-PLC component is connected to a
power supply.
Outputs This list defines the names of the output variables whose values
can be set by the actions of the related GRAFCET. Specifying a name
is optional. The output variable names Q0 to Q7 are created
automatically. A voltage of 24 volts is generated at the electrical
connection corresponding to an output variable if that output
variable has a value not equal to 0 and the GRAFCET-PLC compo-
nent is connected to a power supply. In any other situation, a
voltage of 0 volts is generated.
In the properties dialog box for the GRAFCET PLC component, the
alias E2 is entered for the input I2. The output Q5 was not
given an alias. As soon as the electrical switch is closed, there is a
potential at the input of I2; this potential causes the GRAFCET
variable I2 (and thereby also the alias E2) to change its value
from 0 to 1. As a consequence of this, the condition in the
action becomes true (1) and the value of variable Q5 is set to
196 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
1. This in turn leads to a potential being created at the output of
Q5 and the indicator light lights up.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 197
Figure 10/18: GRAFCET simulation
If the set GRAFCET mode permits it, GRAFCET elements can directly
access the variables of circuit components, with the GrafView
mode allowing only read access and the GrafControl mode allow-
ing both read and write access to the circuit variables. Also, to
permit this access, every variable used in GRAFCET needs to be
identifiable by a unique name. You can see the predefined name for
every variable in the component parameters dialog box. Clicking
the name of a variable opens another dialog box where you can
specify a user-defined alias. This alias is used like a global variable
and can be addressed directly in a GRAFCET.
198 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 10/19: Variables of a voltmeter
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 199
Figure 10/20: Access to circuit variables
200 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
10.5 Monitoring with GRAFCET actions
The settings for monitoring can be set along with the choice of
GRAFCET mode (see "Setting the GRAFCET mode").
Enable monitoring Here you can define whether you want the monitoring to be carried
out during the simulation.
Monitoring condition false If the monitoring condition of an active action is violated, the action
is marked in the color specified.
Action failed Once a monitoring condition fails, or in other words, once the
tolerance time is exceeded, the corresponding action is marked in
the color specified.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 201
Pause simulation on action If this option is activated, the simulation switches to pause mode
failed when a monitoring condition fails.
Play sound on action failed If this option is activated, an audio signal is sounded when a moni-
toring condition fails.
202 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 10/24: Specifying the monitoring condition
Monitoring condition The monitoring condition is entered in this field. Circuit variables
can be assigned to a unit of measurement by writing the desired
unit in square brackets after the variable. This is 1.3.v [m/s] in
the example shown.
Tolerance time In this field you enter the time period after which a violated condi-
tion is categorized as failed.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 203
Figure 10/25: Template of a monitoring condition
Monitoring condition You can use the two drop-down lists to select a template of a moni-
toring condition.
Component Here you can specify the identification of the component to which
the monitoring condition will refer. You can use the Browse...
button to select the component from an additional selection dialog
box.
Variables / Units Here the variables and units are listed which are used in the select-
ed template.
204 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Condition formula The condition generated from the template is shown as a formula in
this field. This formula is transferred into the input field for the
monitoring condition.
Start the simulation and observe how the GRAFCET controls the
circuit and advances and retracts the cylinder piston.
Now close the one-way flow control valve. The solenoid valve still
switches over as a result of the GRAFCET action, but the cylinder
cannot advance now. The monitoring condition of the action is now
violated and the action is marked in yellow to indicate this viola-
tion.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 205
Figure 10/27: Simulation with GRAFCET monitoring
After the set tolerance time of one second, the violated condition is
categorized as failed, the action is marked red, and the simulation
goes into pause mode.
206 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 10/28: Simulation with GRAFCET monitoring
The next sections introduce all GRAFCET concepts that are related
to FluidSIM.
10.6.1 Initialization
All the variables in a GRAFCET are preset with the value 0 at the
start of the simulation.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 207
10.6.2 Sequence rules
Since triggering a transition does not take any time, a step can
be activated and deactivated at the same time (even across
various intermediate steps). An active step remains active in
this situation. A loop of steps is only run through once at one
point in time (see example: Grafcet/Grafcet06.ct).
10.6.4 Synchronization
208 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
10.6.5 Transient sequence / unstable step / virtual triggering
FluidSIM does not check whether the two types of variable identifi-
cation contradict each other for a variable. If this case occurs, the
variable value is determined by an internal calculation, which the
user cannot predict (see example: Grafcet/Grafcet09.ct).
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 209
term in question is displayed in red. The simulation is only released
once all the terms are valid.
There are no limitations for the descriptions that can be shown for
conditions and actions, because these are only displayed and are
not used for simulation.
There are four different types of variables. All variables can be used
in conditions and assignations.
Action Variables Action variables are available throughout GRAFCET and can be set
in actions (see example: Grafcet/Grafcet10.ct).
Step Variables Step variables are inserted automatically for each step and have
the value 1 when and only when the corresponding step is active.
Step variables have the form X + step name. If, for example, the
step name is 12, then the associated variable is X12. Step
names are only ever valid within a partial GRAFCET or within the
global GRAFCET. This means that the same step name can be used
in different partial GRAFCETs. In order to be able to address step
variables across partial GRAFCETs in FluidSIM, the step variable has
to be preceded by the partial GRAFCET name. Example: Partial
GRAFCET 1 contains step 2 and is meant to be addressed in the
global GRAFCET. Within the global GRAFCET, the step variable name
G1.X2 has to be used. Within partial GRAFCET 1, X2 is
enough (see example: Grafcet/Grafcet11.ct). Variables of
macro-steps have the form XM + step name, macro inputs have
XE + step name and macro outputs have XS + step name (see
example: Grafcet/Grafcet15.ct).
210 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Partial GRAFCET Variables Partial GRAFCET variables are automatically inserted for each
partial GRAFCET and have the value 1 when and only when at
least one step in the corresponding partial GRAFCET is active.
Partial GRAFCET variables have the form XG + partial GRAFCET
name. If, for example, the partial GRAFCET name is 1, the asso-
ciated variable is XG1 (see example:
Grafcet/Grafcet12.ct).
Variables of circuit compo- The variables of circuit components can be used in GRAFCETs as
nents input and output variables (see "Access to variables of circuit
components").
+ (logical OR)
* (logical AND)
RE (rising edge)
FE (falling edge)
s / / s (delay)
Examples:
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 211
NOT a
NOT (a + b)
RE X1
RE (X1 * X2)
sin (sine)
cos (cosine)
or
212 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Examples:
1 s / X1 / 2s 3s/X3
Example: NOT(6s/X28)
d (days)
h (hours)
m (minutes)
s (seconds)
ms (milliseconds)
[C > 6 ] * X1
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 213
10.6.13 Target information
10.6.15 Macro-steps
214 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
10.6.16 Compulsory commands
G12 {8, 9, 11} Setting a specific situation. This example activates steps 8, 9 and
11 of partial GRAFCET 12.
G12 {*} Freezing a partial GRAFCET. In this example, the current situation
for partial GRAFCET 12 is maintained as it is. No further transitions
are triggered.
G12 Setting a blank situation. All steps in partial GRAFCET 12 are deac-
tivated in this example.
G12 {INIT} Setting the initial situation. In this example, the steps in partial
GRAFCET 12 that are marked as initial steps are activated.
You have to set the Activation link field in the properties dialogue
for steps within the enclosed partial GRAFCET that you wish to
activate when the enclosing step is activated.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 215
10.6.18 Action when a transition is triggered
216 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Dimension
Chapter 11
11. Dime nsion
The buttons
Horizontal
Vertical
Align
Angular
Flag
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 217
11.2 Settings for the dimension
Factor Determines the factor by which the real length is multiplied for the
displayed value. This is necessary if you are creating a drawing with
a scale other than 1:1.
218 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Line Style Defines the line style for the dimension.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 219
Component attributes
Chapter 12
12. Compone nt attributes
220 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
12.1 Component attributes in the Properties dialog window
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 221
Figure 12/2: Detail from the Properties dialog window for a compo-
nent: General properties
Symbol Name Displays the name of the circuit symbol. The symbol name is
mapped to appropriate products in the Festo product catalogue.
Users cannot edit the symbol name.
Part number The part number uniquely identifies a product within parts lists.
Layer In this selection list you define the drawing layer for the symbol.
Depending on the setting for the drawing layer it may not be possi-
ble to display or edit the symbol. In order to make the symbol
visible or change the settings you have to temporarily activate the
drawing layer on the Drawing Layers... menu item from the View
menu.
Identification Here you can assign an identification that uniquely identifies the
component in the circuit diagram. The identification is shown as
text in the circuit drawing if the Display option is selected.
Display in Parts Lists Deactivate this option if you do not want the symbol to appear in
the parts list.
222 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
12.2 User Defined Properties
You can enter your own component attributes in the User Defined
Properties tab.
Figure 12/3: Detail from the Properties dialog window for a compo-
nent: User Defined Properties tab
A row can be deleted by first clicking the row to highlight it. The
highlighted row can then be deleted using the Del key.
You can add any desired attributes by filling out the empty cells on
the last row.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 223
12.3 Drawing Properties
Figure 12/4: Detail from the Properties dialog window for a compo-
nent: Drawing Properties tab
Scale Defines the scaling in the x or y direction. The scaling factor can
also be defined with the help of the mouse pointer. This is de-
scribed in the Scale symbols section.
Rotation Defines the angle of rotation in degrees. The angle of rotation can
also be defined with the help of the mouse pointer. This is de-
scribed in the Rotate symbols section.
Override Color If this option is activated then another color can be selected for the
symbol.
224 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
12.4 Main and secondary components
Main and secondary components are linked using the symbol for
the secondary component. The circuit diagram detail shows a relay
comprising a coil as the main component and two contacts as the
secondary components. The contacts are to be linked with the coil.
This information is evaluated when displaying the contact image.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 225
Open the corresponding properties dialog window by double-
clicking a contact.
Main Component A compatible main component can be selected from a list. The main
component identification can also be entered directly as text.
Find Target... If the secondary component is logically linked with a main compo-
nent, a search can be performed for the associated main compo-
nent using this button.
226 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Select Q1 from the list of compatible main components.
Proceed in the same way for the second contact.
If you now change the coil identification to Q2, the logical links
mean that the identifications at the contacts will also be automati-
cally changed to Q2.
Examples of this are relays with the coil as the main component and
the contacts as secondary components as well as electromagnetic
directional control valves with the pneumatic symbol as the main
component and the valve solenoids as secondary components in
the electrical part of the circuit diagram.
The following circuit diagram shows a solenoid valve and the sym-
bols for two separate solenoid coils. No link has been established
yet between the solenoid valve and the coils.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 227
Figure 12/8: Solenoid valve and two separate coils
228 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 12/9: Properties dialog window, Connector Labels tab
Electric Connector (Left) The identification for the left-hand solenoid coil can be entered in
this list box or selected from a list. When you click in this field the
corresponding connector is highlighted in the preview. This helps to
locate the connector, particularly when dealing with turned or
mirrored symbols.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 229
Browse... Opens a dialog that shows all compatible solenoid coils as a tree in
accordance with the object hierarchy.
Link If this box is checked then the solenoid coil is logically linked with
the connector at the solenoid valve. If the solenoid coil is renamed
the link is retained and the identifications of the coils at the sole-
noid valve are changed to match the coil identifications.
Find Target... If the connector at the solenoid valve is logically linked with a coil a
search can be performed for the associated coil using this button.
Display If this box is checked the coils identification is shown as the identi-
fication for the solenoid valve connector.
230 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 12/11: Connector dialog window
The (electric) connectors of the solenoid valve are now linked with
the solenoid coils.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 231
Figure 12/13: Properties dialog window for a text component:
232 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 12/14: Detail from the Properties dialog window for a text
component: Edit Text tab
Edit Text Enter your text into the input field on the left-hand side. You can
also enter text with multiple lines. Press the Enter key to create a
line break.
Alignment Defines the horizontal or the vertical alignment of the text within
the text field.
Attribute Link If this option is activated a text that identifies a link to an attribute
is displayed instead of the text entered. The value of the selected
attribute is displayed in the circuit diagram. You can find a detailed
description of this function under Link text components with attrib-
utes. A predefined placeholder such as the page number can also
be selected using the Predefined variable... button.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 233
12.8 Link text components with attributes
Example:
Note: You can open the dialog window of an existing text compo-
nent by double-clicking it or using the Edit menu and the Prop-
erties... menu item.
Activate the Attribute Link option and then click the Browse...
button.
234 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 12/15: Browse Attributes dialog window
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 235
12.9 Text components with specified links
Alignment Defines the horizontal or the vertical alignment of the text within
the text field.
Note: You can also change the text size by selecting another font
size in the font type dialog window. You open this dialog window
using the Font... button under Text Attributes.
236 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Color... Defines the text color.
Find Target... The target of a linked text is the attribute which the text refers to.
This button opens the Properties dialog window of the object which
contains this attribute.
The following tabs are available for the common properties de-
pending on the objects highlighted.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 237
Figure 12/17: Properties dialog window, Drawing Properties tab:
several highlighted objects
Background Sets the location of the drawing element to the background. This
means that all of the circuit symbols are on top of this. In particular
this means that symbols are not covered by filled drawing ele-
ments, for example.
238 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Foreground Sets the location of the drawing element to the foreground. This
means that all of the circuit symbols are underneath this. In particu-
lar it means that symbols are covered by filled drawing elements,
for example.
Main Component A compatible main component can be selected from a list. The main
component identification can also be entered directly as text.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 239
Find Target... If the secondary component is logically linked with a main compo-
nent, a search can be performed for the associated main compo-
nent using this button.
240 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Parts list management and analyses
Chapter 13
13. Parts list manage ment a nd a nalyses
The use of parts lists is described below. The use and function of
the other analyses are described in the corresponding chapters.
You can customize the appearance of the parts list under Proper-
ties... in the Appearance tab. You can see the effects of the
settings straight away in the preview on the right-hand side.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 241
If the Lines per Page option is selected you can specify the num-
ber of lines to be displayed per page. The relevant pages will also
be output when the circuit diagram is printed. Buttons for naviga-
tion are displayed underneath the page if the list is split across
multiple pages.
A parts list is displayed as a table in the window. You can edit the
following options for editing the table:
Attributes which the user can edit can be entered directly into
the corresponding table field.
242 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
13.2 Find components from the parts on the circuit diagram
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 243
Figure 13/3: Finding components from the parts list
244 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
cuit diagram is already open in another window than the parts
list view remains in the active window. The already opened
window containing the circuit diagram is moved into the fore-
ground and an animation identifies the corresponding circuit
diagram symbol.
When you click a cell in the parts list table an animation identi-
fies the corresponding component in all of the opened windows
displaying the circuit diagram.
If you click a column header in the parts list table then both the
entire column of the parts list as well as the corresponding
components in the associated circuit diagram windows are se-
lected.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 245
Figure 13/4: Parts List Properties dialog window: Included Pages
tab
Accumulated Parts List Compiles the components with the same attributes.
Include This Pages Compo- Only lists the components of the corresponding circuit diagram.
nents Only
Include All Project Files Lists all of the components of the active project.
Include Selected Files: Lists all of the components of the selected circuit diagrams belong-
ing to the active project.
246 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 13/5: Parts List Properties dialog window: Listed Attributes
tab
List All Attributes Lists all of the component attributes within a parts list row.
List Selected Attributes: Only lists selected component attributes within a parts list row.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 247
Figure 13/6: Parts List Properties dialog window: Print Options tab
In this tab you can adjust the appearance of the parts list printout.
In the preview on the right-hand side you can immediately see the
effects of the adjustments. You can find information regarding
printing a parts list in the Print circuit diagram and parts list
section.
248 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
A dialog window for selecting a file or entering a new file name
appears. After you have entered a file and left the dialog field you
can define the following format settings for the export in the Parts
List Export dialog window:
Column Header If this option is selected then the names of the attributes appear in
the first row of the text file.
Quotation Marks Select this option to set the field elements in quotation marks.
In the Insert menu, select Tube List to insert a tube list into
the circuit diagram. Alternatively you can click the button.
In the selection dialog box that opens, select Tube List .
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 249
The mouse pointer changes to a crosshair. Click the position in the
circuit diagram where you want to insert the tube list. A dialog
window then opens where you can select the associated tubing and
customize the appearance.
Include This Pages Compo- Lists only the tubes in the associated circuit.
nents Only
Include All Project Files Lists all tubes in the active project.
Include Selected Files: Lists all tubes in the selected circuit in the active project.
250 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 13/9: Tube List dialog window, Appearance tab
You can customize the appearance of the tube list on the Appear-
ance tab. You can see the effects of the settings straight away in
the preview on the right-hand side.
If the Lines per Page option is selected, you can specify the
number of lines to be displayed per page. The relevant pages will
also be printed in a printout of the circuit diagram. Buttons for
navigation are displayed underneath the page if the list is split
across multiple pages.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 251
Manage projects
Chapter 14
14. Manage pr ojects
Project files possess the prj file suffix. By default they only contain
links to files contained in the project. If you wish to pass on a
project then you must either pass on all of the associated files
along with the project file or activate the Save Projects as Single
File option.
252 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
14.2 Project nodes
Under the Properties... menu item from the Project menu you
can define properties for the project. Properties that can be speci-
fied for both projects and circuits are described under Circuit and
project properties.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 253
Figure 14/1: Project dialog window: Archiving tab
Save Projects as Single File If this option is activated all of the files belonging to the project are
saved in a single file.
A circuit node is created beneath the project node for every circuit
file that belongs to the project. This also applies to parts lists since
they are saved as circuits. These are just displayed differently in the
window. All of the circuit-specific or parts list-specific properties are
saved with the circuit node.
Open...
254 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Close Windows Closes the window of the selected circuit or the selected parts list.
Remove From List Removes the selected circuit or the selected parts list from the
project.
Rename... Changes the description of the selected circuit or the selected parts
list.
Properties... In this dialog window you can enter data for the circuit or parts list.
Here you can define the circuit dimensions and orientation, both of
which are relevant for printing.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 255
Circuit and project properties
Chapter 15
15. Circuit and project pr operties
Properties The file name field displays the file name of the circuit or project
along with the complete path. The file name is carried over to the
input field for the Description and can be edited there. This entry
is displayed in the upper margin of the window as well as beside
the circuit or project node.
Page number Here you can specify a page number. The page number can be
made up of any character string. The page number can be defined
using the %PageNumber predefined placeholder. This placehold-
er can be used in text components and drawing frames among
others.
256 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Drawing Frame Here you can make settings for the drawing frame. This function is
described in the section Drawing frame.
15.1 Attributes
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 257
Figure 15/2: Attributes tab
Action The buttons in this column allow the following actions: if the attrib-
ute was created in the parent project node then the Find Target...
action is available. Clicking this opens the Project or Circuit dialog
window for the project node as the target that contains the corre-
sponding attribute. If the attribute was created in the same node
then the Delete action that allows you to delete the attribute is
available.
Inherit From Project If the attribute was created in the same node then this option is
deactivated and grayed out. This applies to all of the attributes of
the project node since it does not have a parent node. For child
nodes the value of the attribute from the project node is copied
when this option is activated. After deactivating this option it is
possible to locally overwrite the attribute value.
258 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
15.1.1 Predefined placeholders
%PageNumber
If analyses are split across several pages, the number of the sub-
page is added to the page number with a minus sign. If, for exam-
ple, the entered page number is 42-01 and the page displayed is
the third page in an analysis then the placeholder %PageNumber
is replaced by the character string 42-01-03.
%PageDescription The description for the page is specified in the properties dialog
window for the circuit diagram.
%PageFileName Stands for the file name of the page without the file path.
%PageFullFilePath Stands for the file name of the page with the full file path.
%PageFileDateTime Stands for the date and time of the most recent change to the
circuit diagram.
%PageFileDate Stands for the date of the most recent change to the circuit dia-
gram.
%PageFileTime Stands for the time of the most recent change to the circuit dia-
gram.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 259
15.2 Page Dividers
Page dividers can only be defined for pages. Editing of page divid-
ers is described under Page dividers.
260 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 15/3: Basic Unit Length tab
The Basic Unit Length tab is also in the project settings. The set-
tings made in this tab are used as a template for circuit diagrams
created from new in the project tree.
15.4 Encryption
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 261
Figure 15/4: Encryption tab
Enable Encryption This option activates and deactivates encryption. When encryption
is activated the password to be used can be entered in the Pass-
word input field.
262 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
15.5 Cross Reference Representation
This tab is used to define the settings for the cross-reference repre-
sentation. You can find further information under Cross-reference
representation. If the Inherit From Parent Node option is active then
the settings will be copied from the parent project node.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 263
Special functions for electric circuits
Chapter 16
16. Special functions for electric circuits
You open a dialog window where you can make the settings shown
using the Insert Conduction Line... menu item or the button
on the toolbar.
264 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 16/1: Settings for the potential lines to be created
You can then define the end points of the line with two consecutive
mouse clicks.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 265
Figure 16/3:
266 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
If the cable symbol represents a cable then a cable object must be
assigned to the symbol. Product properties can be saved in the
cable object and are analyzed in cable maps and cable lists, etc.
Several cable symbols can reference the same cable object. This is
the case if, for example, a cable has to be spread over several
pages.
Select the Cable menu item from the Insert menu or click
the button to define a cable or wiring.
If you want to use a cable instead of wiring you can assign a cable
object to the symbol using the properties dialog window for the
cable symbol.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 267
Figure 16/6: Cable Symbol dialog window, Wires tab
Cable Wiring Defines whether the cable symbol represents a cable or wiring
comprising single wires. Wiring is not listed in cable maps, etc. If
Wiring is selected then an identification can be specified that can
be displayed with Display Identification.
Wires In order to analyze cable maps the component connections that join
a wire must be determined. The connectors are automatically
entered in the list box if they can be uniquely assigned. If a unique
assignment is not possible, the relevant connector must be select-
ed manually via the list box. The identification for the individual
268 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
wires can also be entered. These are saved in the individual lines
(wires). The wire identifications are displayed at the cable symbol
using the Display button.
Reverse Direction The entries in the From and To column are automatically defined as
the direction of the wires when creating the cable symbol. Clicking
the Reverse Direction button reverses the directions of all of the
wires.
Renumber From: Clicking this button renumbers all of the wires defined by the cable
symbol, starting with the number entered in the list box.
In the Display Attributes tab you can select the attributes of the
associated cable object that are to be displayed at the cable sym-
bol.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 269
Figure 16/8: New Cable dialog window
Containing Page Indicates the page where the cable object will be saved. This is
important if various cable symbols on different pages reference the
same cable object. The cable object is only saved with one page.
Number of Wires Enter the number of lines (wires) in the cable here. The number can
be higher than the underlying lines if, for example, a concrete cable
has unconnected wires. If the associated cable symbols overscore
more lines than are defined in the cable object, a warning is output
when the page is checked and the corresponding entries are high-
lighted in color in the cable lists.
After you specify the identification for the cable and confirm the
dialog, the cable object is generated and the cable symbol is as-
signed to it.
270 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 16/9: Properties dialog window: Cable tab
Number of Wires Defines the number of lines (wires) in the cable. The number can be
higher than the lines overscored by the associated cable symbols if,
for example, a concrete cable has unconnected wires. If the associ-
ated cable symbols overscore more lines than are defined in the
cable object, a warning is output when the page is checked and the
corresponding entries are highlighted in color in the cable lists.
The associated cable symbols are listed in rows in the table. You
can jump to the associated cable symbol using the Find...
button.
The User Defined Properties tab in the properties dialog window for
the cable symbol lists the cable-specific product properties such as
Cable Type and Length. These properties and the entries in the
Cable tab are analyzed in the cable map, etc.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 271
16.2.1 Manage cables
All cables within a circuit can be listed and renamed using the
Manage Cables... menu item from the Page menu. You open the
properties dialog window for the relevant cable object using the
Properties... button.
You can also call up the cables of all circuits belonging to the pro-
ject using the Manage Cables... menu item from the Project
menu.
Containing Page Shows which circuit the cable is assigned to. You can edit this
assignment within a project.
You can add a new cable object to the project using the Create
New... button. Each cable object must be assigned to a page.
272 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Clicking the Create New... button first opens the following dialog
window where you can define the assignment.
After you click the Select button a dialog window opens where
you can define the name and number of wires for the new cable
object. The dialog window is described under Cables and wiring.
You can insert an associated cable map for a cable into the circuit
diagram. You do this by inserting a cable map into a circuit diagram
and then assigning a cable to this map.
To insert a cable map into the circuit diagram select the Cable
Map menu item from the Insert menu. Alternatively you can
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 273
click the button. Select Cable Map in the selection dialog
window that opens.
Properties... Opens the properties dialog window for the associated cable sym-
bol.
274 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
You can customize the appearance of the cable map in the Ap-
pearance tab. You can see the effects of the settings straight away
in the preview on the right-hand side.
If the Lines per Page option is selected you can specify the num-
ber of lines to be displayed per page. The relevant pages will also
be output when the circuit diagram is printed. Buttons for naviga-
tion are displayed underneath the page if the list is split across
multiple pages.
To insert a cable list into the circuit diagram select the Cable
List menu item from the Insert menu. Alternatively you can
click the button. Select Cable List in the selection dialog
window that opens.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 275
Figure 16/14: Cable List dialog window, Included Pages tab
Include This Pages Compo- Lists only the cables in the associated circuit.
nents Only
Include All Project Files Lists all cables in the active project.
Include Selected Files: Lists all cables in the selected circuit in the active project.
276 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 16/15: Cable List dialog window, Appearance tab
You can customize the appearance of the cable map in the Ap-
pearance tab. You can see the effects of the settings straight away
in the preview on the right-hand side.
If the cable symbols of a cable object overscore more lines than are
defined in the cable object, a warning is output when the page is
checked and the corresponding entries are highlighted in color in
the cable list.
If the Lines per Page option is selected you can specify the num-
ber of lines to be displayed per page. The relevant pages will also
be output when the circuit diagram is printed. Buttons for naviga-
tion are displayed underneath the page if the list is split across
multiple pages.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 277
Figure 16/16: Buttons for navigating through lists
To insert a wiring list into the circuit diagram select the Wir-
ing List menu item from the Insert menu. Alternatively you
can click the button. Select Wiring List in the selection di-
alog window that opens.
278 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 16/17: Wiring List dialog window, Included Pages tab
Include This Pages Compo- Lists only the wirings in the associated circuit.
nents Only
Include All Project Files Lists all wirings in the active project.
Include Selected Files: Lists all wirings in the selected circuit in the active project.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 279
Figure 16/18: Wiring List dialog window, Appearance tab
You can customize the appearance of the wiring list in the Appear-
ance tab. You can see the effects of the settings straight away in
the preview on the right-hand side.
If the Lines per Page option is selected you can specify the num-
ber of lines to be displayed per page. The relevant pages will also
be output when the circuit diagram is printed. Buttons for naviga-
tion are displayed underneath the page if the list is split across
multiple pages.
280 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 16/19: Buttons for navigating through lists
Figure 16/20:
As soon as you have set a new terminal in this way the dialog
window containing the settings for this terminal appears. You can
use this dialog window to assign the terminal to a terminal strip.
This assignment can also be made or changed later.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 281
Figure 16/21: Terminal dialog window
Display If this box is checked then the description entered will be displayed
beside the terminal.
Pos. Defines the position of the terminal within the associated terminal
strip. An entry is only possible once the terminal has been assigned
to a terminal strip.
Internal # External Changes the direction of the terminal. The direction is indicated in
the circuit by an arrow that shows which connector is inside the
control cabinet and which is outside. The tip of the arrow points
into the control cabinet.
Show Direction If this box is checked then the direction arrow is displayed at the
terminal.
Terminal Strip Defines the terminal strip containing the terminal in question. The
list contains the terminal strips already created. You call up the
properties dialog window for the selected terminal strip using
282 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Properties... . You can also create a new terminal strip using
Create New... .
Display Identification If this box is checked then the identification for the associated
terminal strip is displayed beside the terminal.
Figure 16/22:
The operation begins with a dialog window where you can make
some settings for the new terminals. Above all you need to first
select an existing terminal strip or create a new one. If a suitable
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 283
terminal strip does not already exist then a prompt to create a new
one will automatically appear.
Description Defines how the new terminals are to be numbered. The Enumerate
Manually option allows you to specify a start number from which
the numbering continues. Otherwise a free terminal from the se-
lected terminal strip is automatically used. The start number 2
was specified in the example shown.
Display If this box is checked then the description entered will be displayed
beside the terminal.
Direction Defines the direction of the new terminals. The direction is indicat-
ed in the circuit by an arrow that shows which connector is inside
the control cabinet and which is outside. The tip of the arrow points
into the control cabinet. The direction can also be changed later
using the properties dialog window for the individual terminals.
Terminal Strip Defines the terminal strip containing the terminals in question. The
list contains the terminal strips already created. You call up the
properties dialog window for the selected terminal strip using
284 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Properties... . You can also create a new terminal strip using
Create New... .
Display Identification If this box is checked then the identification for the associated
terminal strip is displayed beside the new terminals.
FluidSIM does not treat terminal strips as visible objects within the
circuit pages which explains why they cannot be interactively
selected using the mouse in order to highlight them, delete them or
change their properties. Terminal strips can either be managed via
the associated terminals or using the Manage Terminal Strips...
menu item under Page or Project .
All properties can also be changed later at any time. You open the
properties dialog window for a terminal strip via any terminal in
that terminal strip using the Properties... button.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 285
Figure 16/25: Terminal Strip dialog window
External Target If the target of a terminal inside the control cabinet is unique due to
the wiring, FluidSIM automatically enters the identification for the
connected component. Otherwise the list contains the identifica-
tions of all objects that can be reached from the terminal. The
target search can be controlled by selecting a junction symbol as a
T distributor.
Internal Target The targets of the terminals outside the control cabinet are listed
here. As with the internal targets, unique links are automatically
entered.
All terminal strips within a circuit can be listed and renamed using
the Manage Terminal Strips... menu item from the Page menu.
You open the properties dialog window for the relevant terminal
strip using the Properties... button.
286 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
You can also call up the cables of all terminal strips belonging to
the project using the Manage Terminal Strips... menu item from
the Project menu.
Containing Page Shows which circuit the terminal strip is assigned to. You can edit
this assignment within a project.
You can add a new terminal strip to the project using the Create
New... button. Each terminal strip must be assigned to a page.
Clicking the Create New... button first opens the following dialog
window where you can define the assignment.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 287
Figure 16/27: Browse Pages dialog window
After you click the Select button a dialog window opens where
you can define the properties of the new terminal strip. The dialog
window is described under Create terminal strips.
288 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
The mouse pointer changes to a crosshair. Click the position in the
circuit diagram where you want to insert the terminal diagram. A
dialog window then opens where you can assign the relevant
terminal strip and customize the appearance.
Properties... Opens the properties dialog window for the associated terminal
strip.
If the Lines per Page option is selected you can specify the num-
ber of lines to be displayed per page. The relevant pages will also
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 289
be output when the circuit diagram is printed. Buttons for naviga-
tion are displayed underneath the page if the list is split across
multiple pages.
You can set so-called links in a terminal strip. These links are drawn
in the circuit diagram as regular electric lines and marked as links.
The representation of the T distributors can be customized using
their properties dialog window.
290 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 16/29:
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 291
Figure 16/30:
The properties dialog window for the electric line opens. The op-
tions for setting the links are in the top right:
FluidSIM tracks the line across one distributor point at most. This
means that the specified link will find the contacts 7 and 8. This
link will be represented in the terminal diagram as follows.
292 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 16/32:
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 293
Figure 16/33:
294 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 16/34:
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 295
Figure 16/35: Contact Image dialog window
The Contacts tab lists all of the associated contacts. You can
jump to the corresponding contact in the circuit diagram using the
Jump to Target button.
296 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Circuit input and output
Chapter 17
17. Circuit input and output
FluidSIM circuits and parts lists can be printed by opening the Print
dialog window via the Print... menu item on the File menu.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 297
Figure 17/1: Print dialog window:
Printer Select the desired output device from the list of the available print-
ers.
Properties... This button enables you to open the dialog window for setting the
printer options.
Print to File Activate this option if you wish to write the print data to a file.
Print Project Files When you work in a project you can select which circuits and parts
lists are to be printed.
Copies
298 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Select the number of copies. If the printout consists of multiple
pages you can cause FluidSIM to print a correspondingly sorted
sequence.
Scale You can increase or decrease the output size by entering a scaling
factor. If the dimensions of the area to be printed are larger than
the printable area on the paper then the printout is spread across
multiple pages (tiled). You can see the page divisions in the print
preview.
Page Here you can specify additional margins in order to manually cus-
tomize the print area.
Margins You can select which page the print preview displays.
Files saved in the DXF format can be imported and retain most of
their element attributes. If several special points were taken into
account when creating the drawing using a CAD program then
FluidSIM can easily expand the symbol library.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 299
Figure 17/2: Export Page dialog window
You are then prompted to select a file name or enter a new one.
300 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Options
Chapter 18
18. Options
You can access the various program settings in the Options dialog
window via the Options... menu item on the Tools menu.
18.1 General
Frame fluidic identification Activate the Frame fluidic identification option if you want fluidic
identifications to be framed automatically. This simplifies the
depiction of circuits in accordance with standards.
Frame Electric Identification Activate the Frame Electric Identification option if you want electri-
cal identifications to be framed automatically. This simplifies the
depiction of circuits in accordance with standards.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 301
Zoom Here you can set how you can zoom in or out of the page view with
the mouse.
Display initially actuated When this option is activated, make switches that are actuated in
closer as opener their initial position are displayed as break switches. Conversely,
break switches that are actuated in their initial position are dis-
played as make switches.
Grid Here you can set the grid width and the style. To display the grid,
select the Show Grid menu item on the View menu.
18.2 Save
Compress Files FluidSIM normally compresses the saved files in order to save
space on the disk. If you deactivate the option the files are saved as
XML files without compression. You can find further information in
the Circuit files section.
302 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Create Backup Files The Create Backup Files option causes the previous versions of
saved files are created with the bak file suffix. This enables you to
restore previous versions.
Save New Projects as Single Project files generally consist of links to the files contained therein.
File However, where desired FluidSIM can also save the project along
with all of the associated circuit files in one single file. This serves
to simplify passing on or archiving the project, among other things.
You can set whether a project saves links or all of the associated
files using the Project dialog window Properties of the project.
This option defines the default setting for new projects.
Create Folder For New Pro- A folder with the project name where all project files are stored is
jects automatically generated when a new project is created if this op-
tion is active.
Page Files This is the default path for opening and saving circuits.
Project Files This is the default path for opening and saving projects.
Library Files This is the default path for opening and saving libraries.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 303
Drawing Frames This is the default path for opening and saving drawing frames.
18.4 Language
Program Defines the languages for the program interface including dialog
windows and messages.
18.5 Dimension
This tab is used to define the default settings for the dimensions.
You can find further information under Dimension.
304 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 18/5: Options dialog window: Dimension tab
Layer Defines the drawing layer where the newly generated dimensions
are placed.
Scale Factor Determines the factor by which the real length is multiplied for the
displayed value. This is necessary if you are creating a drawing with
a scale other than 1:1.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 305
18.6 Cross Reference Representation
This tab is used to define the default settings for the cross-
reference representation. You can find further information under
Cross-reference representation.
306 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
18.7 Connector Links
Allow connections between Only connectors of the same type can be connected if this option is
same connector types only active. For example a line from an electric connector to a pneumatic
connector cannot be created in this case.
Pneumatic Horizontal Pneumatic connectors that are on one horizontal line will be auto-
matically connected when a symbol is inserted or moved.
Pneumatic Vertical Pneumatic connectors that are on one vertical line will be automati-
cally connected when a symbol is inserted or moved.
Electric Horizontal Electric connectors that are on one horizontal line will be automati-
cally connected when a symbol is inserted or moved.
Electric Vertical Electric connectors that are on one vertical line will be automatical-
ly connected when a symbol is inserted or moved.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 307
18.8 Warnings
Show Warnings Different types of warnings that FluidSIM should or should not
deliver can be activated and deactivated here. These warnings
include Duplicated identification labels and Superimposed
objects.
Enable Background Check All of the circuits will be checked during editing if this option is
active. Only the criteria that would lead to the warnings specified
under Show Warnings are checked. Objects that caused an error
are highlighted in red in the circuit. If this option is not active then
the check must be initiated manually using the Page Check
Drawing menu.
308 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
18.9 Automatic Updates
Check for updates at startup FluidSIM can search on the Internet for a new version when the
program starts. You can activate or deactivate the automatic search
here.
Check for updates now... As soon as there is an Internet connection you can use this button
to initiate the search for a new FluidSIM version.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 309
18.10 Simulation
Display interval Normally FluidSIM calculates all data required for the simulation
automatically, without bothering the user with mathematical de-
tails. However, in some cases it can be useful to specify a certain
increment, for example, in order to achieve a more accurate display
of high frequencies in electronics. For instance, if you want a reso-
lution in the microsecond range, enter an increment of at least
0.000001 (or in scientific notation 1e-6).
Slow-motion factor You can use this factor to set the ratio of time in which the simulat-
ed processes should take place. A value of 1:1 means simulation
in real time; 1:10 would mean that the simulation takes place in
slow motion, in this case ten times slower than in reality. A ratio of
1:0.1, for example, would mean the simulation is accelerated ten
times. Specifications for real time or accelerated processes can only
be fulfilled if the computer has sufficient processing power.
310 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Line colors During the simulation, the pneumatic, hydraulic, electrical, and
digital lines will be colored according to their state. You can cus-
tomize the colors for each state.
Digital Technique (Compati- In digital technology, it is useful if unused inputs on AND, NAND,
bility with Siemens and NOT components are automatically set to Hi. Otherwise, for
LOGO!Soft) example, an AND gate with three inputs would not function as
expected if only two inputs were wired. So that the circuit does not
become cluttered with unnecessary permanently Hi level signals,
FluidSIM can set unused inputs on the relevant components to Hi
automatically. If you do not want this automatic function, you can
switch it off. To prevent misunderstandings regarding unused
digital inputs, FluidSIM displays a corresponding message at the
start of every simulation. If you do not want this message to ap-
pear, you can switch it off.
Note that these values are only used if no others are defined in the
page or project properties.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 311
18.11 GRAFCET
GRAFCET mode Here you can set the mode that FluidSIM will apply when handling
GRAFCETs during the simulation.
GrafEdit (GRAFCET is not In this mode, GRAFCETs are treated as drawings only. They are not
simulated) incorporated into the simulation. See also Drawing only (GrafEdit).
GrafView (GRAFCET visual- This mode uses GRAFCETs for visual presentation of the simulation.
izes simulation) The defined actions, however, have no effect on the simulation. In
particular, they do not in any way control the fluidic or electrical
components. See also Observation (GrafView).
GrafControl (GRAFCET con- In this mode, the GRAFCET has access to all the circuit variables
trols simulation) that can be set from outside. This allows it to switch valves over or
to adjust throttle valves See also Control (GrafControl).
Enable monitoring When this option is switched on, the GRAFCET monitors the proper
functioning of a fluidic or electrical circuit. For this purpose, you can
formulate conditions in the actions which will be checked during
the simulation. For more details, see Monitoring with GRAFCET
actions.
312 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Note that these settings are only used if no others are defined in
the page or project properties.
Here you can set the default values for the DDE interface.
Note that the server name is a global setting of the specific system
environment and is not saved with the circuit data. If you want to
use the DDE interface in other environments, ensure that the DDE
options are adapted accordingly. In particular, ensure that the DDE
connection is activated, because it is switched off by default for
security reasons.
Here you can set the default values for the environment parame-
ters.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 313
Note that these values are only used if no others are defined in the
page or project properties.
Fluid type This list contains typical oils and other fluids. If you select a prede-
fined fluid, the listed values will be set accordingly.
Note that these values are only used if no others are defined in the
page or project properties.
18.15 Sound
When you click the Sound tab in the Options... menu, a dialog
box appears with parameters for the sound settings:
314 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 18/15: Options dialog window: Sound tab
Enable sound You can activate/deactivate an audible signal for the components
Switch/Contact, Relay, Valve, Cylinder, and Buzzer.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 315
18.16 Text Sizes
This tab defines the font sizes to be used for objects newly inserted
into the circuit diagram.
Label/Attribute This group lists the font sizes used for identifications and cross-
references, etc.
List/Table This group lists the font sizes used for analyses and tables.
316 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Menu overview
Chapter 19
19. Menu overview
19.1 File
New
New / File...
Opens a new window for creating a new circuit drawing.
New / Project...
Opens the dialog window for creating a new project.
Open
Open / File...
Opens a new window for selecting an existing circuit drawing.
Open / Project...
Opens the dialog window for selecting an existing project.
Add
Adds files, etc. to the active project.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 317
Add / New Page...
Creates a new circuit file and adds it to the active project.
Close
Closes the active window or project, etc.
Close / File...
Closes the active window.
Close / Project...
Closes the active project.
Save File
Saves the circuit diagram in the active window to disk.
Save Project
Saves the active project.
318 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Save Project As...
Saves the active project under a new name on the data storage
medium. Files that are within the project folder are duplicated while
references to external files are left. With external file references you
must therefore consider that changes to these files affect all pro-
jects containing them.
DXF Import...
Opens the dialog window for selecting a saved DXF file. The select-
ed file is subsequently converted into a FluidSIM circuit diagram.
The original file remains unchanged.
Export...
Exports the circuit diagram in the active window to the data storage
medium as a BMP, JPG, GIF, WMF, PNG, DXF or TIF file.
Page Setup...
Sets up the printer properties for a page to be printed.
Print Preview
Opens a print preview as a page view.
Print...
Opens the FluidSIM Print dialog window to set the print options for
the active circuit.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 319
Recent Files
A file can be selected for opening from a list of the recently opened
files.
Recent Projects
The most recently opened projects can be selected for opening
from a list.
Exit
Ends FluidSIM.
19.2 Edit
Undo
Undoes the last editing action for the active circuit.
Redo
Takes back the last undo-action for the active circuit.
Cut
Deletes the selected objects and adds them to the clipboard.
Copy
Copies the selected objects to the clipboard
Paste
Pastes the objects from the clipboard into the active circuit.
320 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Delete
Deletes the selected objects from the active circuit.
Select All
Selects all of the objects from the active circuit.
Group
Groups the selected objects.
Create Cross-reference
Creates a cross-reference.
Ungroup/Break Off
Ungroups the selected groups or macro objects.
Enable Scale
Activates or deactivates the enable scaling mode which enables
the scaling of symbols with the help of the mouse pointer.
Enable Rotate
Activates or deactivates the enable rotate mode which enables
the rotation of symbols with the help of the mouse pointer.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 321
Align
Aligns the selected objects with each other.
Rotate
Rotates the selected objects by 90, 180 or 270 degrees anti-
clockwise. Grouped objects are rotated around the center point of
the group rectangle.
Mirror
Mirrors the selected objects horizontally or vertically. Grouped
objects are mirrored along the axis of the group rectangle.
Properties...
Opens the Properties dialog window for the selected circuit sym-
bols in order to enter the component properties.
19.3 Insert
322 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Conduction Line...
Opens a dialog window that defines the settings for one or more
conduction lines that are to be inserted in the circuit diagram after
the dialog window is confirmed.
Interruption/Potential...
Adds an interruption or an electric potential to the circuit diagram.
Parts List
Inserts a parts list into the circuit diagram.
Terminal
Inserts a terminal into the circuit diagram.
Multiple Terminals...
Inserts multiple terminals into the circuit diagram.
Terminal diagram
Inserts a terminal diagram into the circuit diagram.
Cable
Inserts a cable into the circuit diagram.
Cable Map
Inserts a cable map into the circuit diagram.
Cable List
Inserts a cable list into the circuit diagram.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 323
Wiring List
Inserts a wiring list into the circuit diagram.
Tube List
Inserts a tube list into the circuit diagram.
19.4 Draw
Line
Draws a line by defining two defined end points.
Poly Line
Draws a polyline by defining the vertices with successive mouse
clicks. The drawing operation can be cancelled by pressing the
Esc key or clicking the right mouse button. The last vertex must
be set with a double-click.
Rectangle
Draws a rectangle by defining two diagonally opposite corner
points.
Circle
Draws a circle by defining a middle point and a radius.
324 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Ellipse
Draws an ellipse by defining a middle point and a radii on parallel
axes.
Text
Inserts a text at the mouse position.
Picture
Inserts an image at the mouse position.
Dimension
Inserts a dimension symbol.
19.5 Page
Check Drawing
Checks the active circuit drawing for drawing errors.
Paper Size...
Opens a dialog window enabling you to set the paper size.
Manage Cables...
Opens a dialog window enabling you to manage the cable objects
in the circuit.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 325
Properties...
Opens an dialog window enabling you to set the circuit properties.
19.6 Execute
Stop
Switches the currently active circuit into Edit Mode.
Start
Starts the simulation (animation) in the currently active circuit.
Pause
Pauses the simulation in the currently active circuit without exiting
Simulation Mode.
Reset
Resets a circuit to its initial state when a simulation is running or
paused. The simulation is then restarted immediately.
Single Step
Stops the simulation after a small step. In other words, the simula-
tion is started for a short period of time before being switched back
into pause mode ( ). You can switch into single step mode directly
from an actively running simulation.
326 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Simulate until State Change
Starts the simulation and runs it until a state change happens; the
simulation is then paused ( ). A state change happens when a
cylinder piston moves against a stop, a valve switches over, or a
relay or a switch is actuated. You can switch into state change
mode directly from an actively running simulation.
Next topic
Switches to the next topic in a presentation.
19.7 Didactics
Component description
Opens the help page for the selected component. It contains the
DIN symbol for the component, a short description of the compo-
nent function, the terminal designations, and a list of any adjusta-
ble parameters, with value ranges for those parameters.
Component Library
Opens the reference containing information about the components
in the component library.
Didactics Material
Opens an overview of the didactics material. If you copied the film
files onto your hard disk during installation, the list of training film
chapters will also appear here.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 327
Circuits for exercises (TP)...
Opens a dialog box with exercise circuits for the Festo technology
packages.
Presentation...
Opens a dialog box that you can use to retrieve and create presen-
tations. Presentations allow you to combine separate training
topics into a cohesive teaching unit.
Extended Presentation...
Opens a dialog box that you can use to retrieve existing presenta-
tions in Microsoft PowerPoint format. The presentation files of the
extended presentations are located in the ppx subfolder of your
FluidSIM installation. You can create your own PowerPoint presen-
tations and add them by saving them in ppt or pps format to
the ppx folder.
19.8 Project
328 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Manage Cables...
Opens a dialog window enabling you to manage the cable objects
in the project.
Properties...
Opens the dialog window for entering the project properties.
19.9 View
Circuit Diagram
Switches from the parts list view to the circuit diagram view.
Parts List
Switches to the parts list view.
Library
Shows or hides the libraries window.
Project
Shows or hides the window for managing the project files.
Standard Size
Displays the circuit diagram in its original size.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 329
Previous View
Displays the previous view of the circuit diagram. Repeatedly
activating this function switches back and forth between the views
previously used.
Fit to Window
Set the zoom level to fit the entire circuit diagram into the window.
View Detail
Defines the new view by drawing a rectangle while holding down
the left mouse button.
Zoom In
Zooms the view of the circuit diagram in by one step. Three steps
correspond approximately to doubling the zoom factor.
Zoom Out
Zooms the view of the circuit diagram out by one step. Three steps
correspond approximately to halving the zoom factor.
Show Grid
Shows a background grid in the active circuit window. The grid
settings can be made in the General tab under the Options...
menu item from the Tools menu.
330 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Show Rulers
Shows or hides the rulers in the active circuit window.
Quantity Values...
Opens a dialog box for display of quantity values. Here you can
define how each quantity value listed (velocity, pressure,
current, ...) is to be displayed ( None , Individual , All ).
GRAFCET...
Opens a dialog box for display of GRAFCET descriptions. Here you
can set whether to display the descriptions or the formulas of
GRAFCET elements. Note that this option may overwrite the specific
settings of individual elements.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 331
Show Connector Descriptions
Shows or hides the connector descriptions. The Display option can
be selected in the properties dialog window for the connectors. This
option is only evaluated if Individual was selected.
332 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Display Contact Images
Shows or hides the contact images.
Drawing Layers...
Opens a Drawing Layers dialog window enabling you to set the
properties of the drawing layers.
19.10 Library
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 333
Rename Active Library...
Opens a dialog window for entering the name of the library. This
function is only available to libraries which the user has created.
For write-protected libraries the folder name is shown in the tab.
19.11 Tools
Options...
Opens the dialog window with program settings, file paths and
language options.
Expert Mode
Switches Expert Mode on and off. Expert Mode provides advanced
options for editing and simulation.
Restore Defaults...
Resets the program settings to the default values. This enables you
to undo unintentional settings made.
Note: Use this function if you feel that FluidSIM is behaving unex-
pectedly or files and windows have suddenly disappeared.
334 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
19.12 Window
New Window
Opens a window with an additional view of the active window.
Navigation Pane
Opens an overview window with a scaled-down view of the entire
circuit diagram. The currently visible area of the active window
appears as a white area. The non-visible area of the drawing is
shaded grey. By drawing a rectangle in the overview window with
the mouse pointer you can define the section of the circuit diagram
displayed in the active window. Simply left-clicking on the overview
window moves the visible area while retaining the zoom level.
Cascade
Arranges the windows so that they overlap.
Tile Horizontally
Arranges the windows into horizontal tiles.
Tile Vertically
Arranges the windows next to each other.
Close All
Closes all open windows.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 335
19.13 Help
Contents
Displays the contents of the FluidSIM help pages.
Index
Displays the index of the FluidSIM help pages.
Search
Displays the search dialog for the FluidSIM help pages.
Register as user...
Opens a dialog box via which you can register if you would like
assistance and information about FluidSIM.
About...
Displays the FluidSIM program information.
336 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Functional diagram
Chapter 20
20. Functional diagra m
You can find the function diagram in the standard FluidSIM library.
You can apply the functions from the Edit menu to the function
diagram. Double-click the function diagram or open the Functional
diagram using the Properties... menu item on the Edit menu.
The buttons in the upper toolbar of the editor are for editing a
function diagram. The following six buttons determine the editing
mode:
Edit Mode
If you hover the mouse pointer over a button for a short period of
time then a short description is displayed.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 337
Figure 20/1:
If the mouse pointer is moved outside the window area while the
left mouse button is held down the view automatically scrolls.
338 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 20/2:
Text columns Number If the number of text columns is changed than all of the table text
boxes are distributed horizontally and evenly.
Text columns Width If the width of the text columns is changed than all of the table text
boxes are distributed horizontally and evenly.
Diagram columns Number The diagram columns are located on the right-hand side of the
function diagram. The diagram curves can be drawn in this area.
The number of diagram columns can also be changed by dragging
the mouse pointer to the right-hand edge of the diagram.
Color The color which the grid lines are drawn in the diagram area.
The table textboxes are located on the left-hand side of the function
diagram.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 339
Figure 20/3:
Figure 20/4:
Color A selection from sixteen standard colors for the text to be dis-
played.
Width The width of the selected table column can be changed by dragging
the mouse pointer.
Height The height of the selected table column can be changed by drag-
ging the mouse pointer.
Horizontal adjustment The following alignment options are available: Left Center and
Right.
Vertical adjustment The following alignment options are available: Top, Center and
Bottom
340 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Alignment within a table cell If a text within a textbox should resemble a table then set a tab stop
between the text parts. The text is displayed in the textbox in ac-
cordance with the number of tab stops and the specified horizontal
and vertical alignment. To enter tab stops hold down the Ctrl
key.
Examples:
1.
2.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 341
20.1.3 Adjust the presentation of the diagrams
Figure 20/5:
Figure 20/6:
States Number The entry defines the number of states and thus the number of
horizontal lines in the diagram row.
342 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
States Base state Horizontal lines are drawn through the base state with a thin pencil.
Numbering Start column The start column defines which column the numbering should
begin with.
Numbering Start number The start number defines which number the numbering should
begin with.
Numbering Number The number specified how many steps need to be numbered.
Numbering Step width Defines the step width between two numbers.
Numbering Loop If this field is selected then an equals sign and the start number are
always displayed after the last number.
Representation Display If this field is selected then two arrows are displayed.
arrows
Representation Display grid If this field is selected then the background grid is displayed.
Representation Display text If this field is selected then a textbox is shown which can serve as a
1 label. This textbox belongs to the selected row and cannot be
moved to another row.
Representation Display text If this field is selected then an additional textbox is shown which
2 can serve as a label. This textbox belongs to the selected row and
cannot be moved to another row.
1. 2. 3. 4.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 343
If you hold down the left mouse button then supporting points can
be moved as in the selection mode.
Selected supporting points are shown in grey. Use the Del key to
delete a selected symbol.
1. 2.
If you hold down the left mouse button then signaling elements can
be moved as in the selection mode.
Selected signaling elements are shown in grey. Use the Del key
to delete a selected signaling element.
344 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 20/7:
Signal type
Display description If this field is selected then a text is shown which can serve as a
label for the signaling element.
1. 2. 3.
Selected textboxes are shown in grey. Use the Del key to delete
a selected textbox.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 345
In Edit Mode the size and position of a textbox can be changed
using the mouse pointer.
Adjust size:
1. 2. 3.
Move textbox:
1. 2. 3.
Figure 20/8:
346 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Color A selection from sixteen standard colors for the text to be dis-
played.
Frame If this field is selected then a frame is drawn around the textbox.
Horizontal adjustment The following alignment options are available: Left, Center and
Right.
Vertical adjustment The following alignment options are available: Top, Center and
Bottom
Table textboxes
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 347
supporting points then the supporting point is vertically or horizon-
tally aligned.
In the selection mode double-clicking can change the way the line
is displayed.
Figure 20/9:
Display description A framed label on the line and a label next to the framed label is
shown. The framed label can be moved freely along the line. The
additional label can be moved freely.
Start with arrow An arrow is displayed at the beginning of the line. The arrow can be
moved freely along the line.
End with arrow An arrow is displayed at the end of the line. The arrow can be
moved freely along the line.
If you click a finished signal line to activate the Freely move signal
lines mode then a signal logic is inserted. This logic point
(snap point) can then be freely moved along the line 1.
2. 3. + 4. .
In the selection mode you can change how the signal logic is dis-
played by double-clicking on it.
348 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 20/10:
In the Freely draw signal lines signal lines can be drawn from
signals. Left-click a signal and hold down the mouse button. Drag
the mouse pointer to a position which you have selected as the end
point of a signal line. The signal line will be drawn once you release
the mouse button.
1. 2. 3.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 349
mouse pointer over the second supporting point and release the
mouse button.
1. 2. 3.
1. 2. 3.
350 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
20.9 Additional editing functions
20.9.1 Zoom
Using the button the view is reset to the standard zoom level.
Using the button you can undo the last 50 editing steps.
Using the button you can redo the previously undone editing
steps.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 351
The Component Library
Chapter 21
21. The Component Library
Pump unit
Adjustable parameters
Opening pressure: 0 ... 40 MPa (6)
Revolution: 0 ... 5000 1/min (1450)
Displacement: 0.1 ... 5000 cm3 (1.6)
Internal leakage: 0 ... 10 l/(min.bar) (0.002)
352 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Pump unit (simplified)
Adjustable parameters
Delivery rate: 0 ... 500 l/min (2)
Maximum pressure: 0 ... 40 MPa (6)
Internal leakage: 0 ... 10 l/(min.bar) (0)
Adjustable parameters
Revolution: 0 ... 5000 1/min (1320)
Displacement: 0.1 ... 10000 cm3 (1.6)
Maximum pressure: 0.1 ... 40 MPa (6)
Internal leakage: 0 ... 10 l/(min.bar) (0)
Adjustable parameters
Revolution: 0 ... 5000 1/min (1320)
Displacement: 0.1 ... 10000 cm3 (1.6)
Flow rate ratio: 0 ... 100 % (100)
Maximum pressure: 0.01 ... 40 MPa (6)
Internal leakage: 0 ... 10 l/(min.bar) (0)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 353
Proportional pump
Adjustable parameters
Mode of control: Displacement control, Speed control (Displace-
ment control)
Displacement: 0.1 ... 5000 cm3 (1.6)
Revolution (min): 0 ... 5000 1/min (0)
Revolution (max): 0 ... 5000 1/min (1320)
Flow rate ratio (min): 0 ... 1 (0)
Flow rate ratio (max): 0 ... 1 (1)
Maximum pressure: 0.01 ... 40 MPa (6)
Internal leakage: 0 ... 10 l/(min.bar) (0)
The hydraulic power pack is suitable for all basic tests of mobile
hydraulics. The two pumps are both driven by one electric motor.
The vane pump with adjustable delivery rate has a load sensing
pump controller. The fixed displacement pump is secured by a
pressure relief valve. The pump/motor unit sits on the tank. The
return into the tank passes through a return flow filter. The ventila-
tion of the tank is also filtered. The oil level can be seen on the
sight glass with temperature display. The motor is switched on and
off from a control console and is safeguarded against overloading.
Adjustable parameters
Revolution: 0 ... 5000 1/min (910)
Displacement (Variable displacement pump): 0 ... 10000 cm3
(5.6044)
Opening pressure (Variable displacement pump): 0 ... 40 MPa (5)
354 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Spring preload: 0.1 ... 10 MPa (1.17)
Displacement (Fixed displacement pump): 0 ... 10000 cm3
(4.5055)
Opening pressure (Fixed displacement pump): 0 ... 40 MPa (5)
The steering unit is used to steer vehicles that are equipped with
hydrostatic steering.
Adjustable parameters
External torque: -10 ... 10 N.m (0)
Displacement: 0 ... 10000 cm3 (32)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.1)
The steering unit is used to steer vehicles that are equipped with
hydrostatic steering.
Adjustable parameters
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 355
External torque: -10 ... 10 N.m (0)
Displacement: 0 ... 10000 cm3 (32)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.1)
Tank
The tank is integrated into the pump unit and has a pressure of 0
MPa. It can be inserted into the circuit diagram as an independent
component.
The hose is available in 3 lengths: 600 mm, 1500 mm, and 3000
mm. The pressure loss in a hose is taken into account by specifying
a hydraulic resistance. In FluidSIM no pressure loss is simulated
with simple connections between two components.
Adjustable parameters
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.1)
Hydraulic reservoir
Adjustable parameters
356 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Volume: 0.01 ... 100 l (0.32)
Pre-load pressure: 0 ... 40 MPa (1)
Polytropic exponent: 0.5 ... 3 (1.4)
Hydraulic reservoir
Adjustable parameters
Volume: 0.01 ... 100 l (0.32)
Pre-load pressure: 0 ... 40 MPa (1)
Polytropic exponent: 0.5 ... 3 (1.4)
Adjustable parameters
Pre-load pressure: 0 ... 40 MPa (1)
Volume: 0.01 ... 100 l (0.32)
Opening pressure: 0 ... 35 MPa (8)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 357
Filter
Adjustable parameters
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.001)
Cooler
Adjustable parameters
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.001)
Heater
Adjustable parameters
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.001)
Connection (hydraulic)
358 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
may result in leaking oil; FluidSIM thus pops up a warning mes-
sage, if some hydraulic connection was left open. Note that at each
hydraulic connection values for the flow and pressure can be dis-
played.
Line (hydraulic)
Adjustable parameters
Physical model: Ideal connection,Simple resistance, Pipe model
(Hagen-Poiseuille/Blasius) (Ideal connection)
Length: 0.01 ... 1000 m (1)
Inner diameter: 0.1 ... 1000 mm (6.3)
Surface roughness: 0 ... 100 mm (0)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.08)
T-junction (hydraulic)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 359
21.1.2 Configurable Way Valves
The configurable 2/n way valve is a way valve with two connec-
tions, where both its body elements and its operation modes are
user-definable.
Adjustable parameters
Desired position: 0 ... 4 (0)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.164)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
The configurable 3/n way valve is a way valve with three connec-
tions, where both its body elements and its operation modes are
user-definable.
360 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Additionally, the hydraulic connections can be closed with blind
plugs.
Adjustable parameters
Desired position: 0 ... 4 (0)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.164)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
The configurable 4/n way valve is a way valve with three connec-
tions, where both its body elements and its operation modes are
user-definable.
Adjustable parameters
Desired position: 0 ... 4 (0)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.164)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 361
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
The configurable 5/n way valve is a way valve with three connec-
tions, where both its body elements and its operation modes are
user-definable.
Adjustable parameters
Desired position: 0 ... 4 (0)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.164)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
362 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Configurable 6/n way valve
The configurable 6/n way valve is a way valve with three connec-
tions, where both its body elements and its operation modes are
user-definable.
Adjustable parameters
Desired position: 0 ... 4 (0)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.164)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
The configurable 8/n way valve is a way valve with three connec-
tions, where both its body elements and its operation modes are
user-definable.
Adjustable parameters
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 363
Desired position: 0 ... 4 (0)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.164)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
This valve is derived from a configurable 2/n way valve. You find
this valve in the component library Frequently used Way Valves,
under the Library menu.
Adjustable parameters
Desired position: 0 ... 4 (0)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.164)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
364 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
If the cylinder piston actuate the stem, the flow from P to A is shut
off. This valve is derived from a configurable 2/n way valve. You
find this valve in the component library Frequently used Way
Valves, under the Library menu.
Adjustable parameters
Desired position: 0 ... 4 (0)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.164)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 365
3/2-way hand-lever valve
Adjustable parameters
Desired position: 0 ... 4 (0)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.164)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
Adjustable parameters
Desired position: 0 ... 4 (0)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.164)
Positioning time: 1e-4 ... 10 s (0.02)
366 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
Adjustable parameters
Desired position: 0 ... 4 (0)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.164)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 367
4/3-way hand-lever valve with shutoff position (i)
Adjustable parameters
Desired position: 0 ... 4 (0)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.164)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
Adjustable parameters
Desired position: 0 ... 4 (0)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.164)
Positioning time: 1e-4 ... 10 s (0.02)
368 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
Adjustable parameters
Desired position: 0 ... 4 (0)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.164)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 369
4/3-way hand-lever valve with floating position (ii)
Adjustable parameters
Desired position: 0 ... 4 (0)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.164)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
Adjustable parameters
Desired position: 0 ... 4 (0)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.164)
Positioning time: 1e-4 ... 10 s (0.02)
370 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
Adjustable parameters
Desired position: 0 ... 4 (0)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.164)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 371
21.1.4 Solenoid-actuated Directional Valves
Adjustable parameters
Desired position: 0 ... 4 (0)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.164)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
372 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
4/2-way solenoid valve (ii)
Adjustable parameters
Desired position: 0 ... 4 (0)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.164)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
Adjustable parameters
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 373
Desired position: 0 ... 4 (0)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.164)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
Adjustable parameters
Desired position: 0 ... 4 (0)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.164)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
374 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
Adjustable parameters
Desired position: 0 ... 4 (0)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.164)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 375
noids, the valve can be manually actuated. This valve is derived
from a configurable 4/n way valve. You find this valve in the com-
ponent library Frequently used Way Valves, under the Library
menu.
Adjustable parameters
Desired position: 0 ... 4 (0)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.164)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
Adjustable parameters
Desired position: 0 ... 4 (0)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.164)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
376 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
Adjustable parameters
Desired position: 0 ... 4 (0)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.164)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 377
21.1.5 Shutoff Valves
Shutoff valve
Adjustable parameters
Opening level: 0 ... 100 % (100)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.1)
Check valve
Adjustable parameters
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.09)
Adjustable parameters
Opening pressure: 0 ... 40 MPa (0.6)
Pressure regulation range: 0.01 ... 10 MPa (0.864)
378 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.09)
If the input pressure is higher than the output pressure, the check
valve opens. Otherwise it is shut. In addition, the check valve can
be opened via a control line, allowing flow in both directions.
Adjustable parameters
Area ratio: 0.1 ... 10 (3.3)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.093)
If the input pressure is higher than the output and nominal pres-
sure, the check valve opens. Otherwise it is shut. In addition, the
check valve can be opened via a control line, allowing flow in both
directions.
Adjustable parameters
Opening pressure: 0 ... 40 MPa (0.2)
Pressure regulation range: 0.01 ... 10 MPa (0.864)
Area ratio: 0.1 ... 10 (3.3)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.093)
Adjustable parameters
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.093)
Area ratio: 0.1 ... 10 (3.3)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 379
Double non-return valve, delockable
Adjustable parameters
Opening pressure: 0 ... 40 MPa (0.2)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.093)
Area ratio: 0.1 ... 10 (3.3)
Adjustable parameters
Area ratio: 0.1 ... 10 (3.3)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.093)
Adjustable parameters
Opening pressure: 0 ... 40 MPa (0.2)
Pressure regulation range: 0.01 ... 10 MPa (0.864)
Area ratio: 0.1 ... 10 (3.3)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.093)
380 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Shuttle valve
If one of the two input pressures is larger than zero, the shuttle
valve opens (OR function) and the higher input pressure becomes
the output pressure.
Adjustable parameters
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.09)
Two-pressure valve
If both input pressures are larger than zero, the two-pressure valve
opens (AND function) and the higher input pressure becomes the
output pressure.
Adjustable parameters
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.09)
Adjustable parameters
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 381
Opening pressure: 0 ... 40 MPa (3)
Pressure regulation range: 0.01 ... 10 MPa (3.8)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.17)
The valve restricts the pressure at port P to the set value compared
with the pressure at T.
Adjustable parameters
Opening pressure: 0 ... 40 MPa (3)
Pressure regulation range: 0.01 ... 10 MPa (3.5)
Hydraulic resistance (Pressure relief valve): 1e-6 ... 1000
bar.min2/l2 (0.08)
Hydraulic resistance (Non-return valve): 1e-6 ... 1000 bar.min2/l2
(0.06)
The valve restricts the pressure at port P to the set value compared
with the pressure at T.
If the hydraulic force at the sealing cone exceeds the spring force,
the sealing cone lifts out of the seat and allows oil to flow to port T.
The valve closes again once the pressure in port P drops again. The
cushioning piston acts like a shock absorber to increase stability.
The spring pretension can be adjusted at the hand wheel. Oil flows
through the non-return valve when the pressure at port T is greater
382 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
than at P. Since the spring chamber is separated from the oil by the
stem, the pressure in T has no effect on the limiting pressure.
Adjustable parameters
Nominal pressure: 0 ... 40 MPa (3)
Pressure regulation range: 0.01 ... 10 MPa (3.5)
Hydraulic resistance (Pressure relief valve): 1e-6 ... 1000
bar.min2/l2 (0.09)
Hydraulic resistance (Non-return valve): 1e-6 ... 1000 bar.min2/l2
(0.7)
Counterbalance valve
Adjustable parameters
Opening pressure: 0 ... 40 MPa (3.0)
Pressure regulation range: 0.01 ... 10 MPa (1)
Hydraulic resistance (Pressure control valve): 1e-6 ... 1000
bar.min2/l2 (0.1)
Area ratio: 0.1 ... 10 (3)
Hydraulic resistance (Non-return valve): 1e-6 ... 1000 bar.min2/l2
(0.1)
Adjustable parameters
Opening pressure: 0 ... 40 MPa (3)
Pressure regulation range: 0.01 ... 10 MPa (0.7)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.1)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 383
Shutoff/counteracting valve
Adjustable parameters
Opening pressure: 0 ... 40 MPa (3)
Pressure regulation range: 0.01 ... 10 MPa (0.7)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.1)
Adjustable parameters
Spring preload: 0 ... 40 MPa (0.8)
Pressure regulation range: 0.01 ... 10 MPa (0.24)
Hydraulic resistance (P-CF): 1e-6 ... 1000 bar.min2/l2 (0.9)
Hydraulic resistance (P-EF): 1e-6 ... 1000 bar.min2/l2 (0.9)
Hydraulic resistance (CF): 1e-6 ... 1000 bar.min2/l2 (10)
Hydraulic resistance (LS-EF): 1e-6 ... 1000 bar.min2/l2 (1450)
384 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Adjustable parameters
Opening pressure: 0 ... 40 MPa (3.5)
Pressure regulation range: 0.01 ... 10 MPa (3.5)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.08)
The valve is closed in the idle position. The hydraulic fluid drains off
at T, when the pressure difference at the connections P and T
exceeds the nominal pressure. If the pressure falls below the preset
value, the valve closes again. The flow direction is marked with an
arrow. The pilot operated pressure relief valve consists of a pilot
stage and a main stage. When open, there is less volumetric flow at
the pilot stage that leads to connection Y. The hydraulic resistance
relates to the completely opened valve.
Adjustable parameters
Opening pressure: 0 ... 40 MPa (3.5)
Pressure regulation range: 0.01 ... 10 MPa (3.5)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.08)
Shut-off-/counterbalancing valve
The valve connects port P with port T if the pressure set at control
port X is exceeded.
Adjustable parameters
Opening pressure: 0 ... 40 MPa (3)
Pressure regulation range: 0.01 ... 10 MPa (0.7)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.1)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 385
2-way pressure reducing valve
Adjustable parameters
Nominal pressure: 0 ... 40 MPa (1)
Pressure regulation range: 0.01 ... 10 MPa (0.2)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.1)
Adjustable parameters
Nominal pressure: 0 ... 40 MPa (1)
Pressure regulation range: 0.01 ... 10 MPa (0.2)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.1)
Adjustable parameters
386 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Nominal pressure: 0 ... 40 MPa (3)
Pressure regulation range: 0.01 ... 10 MPa (1.9)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.1)
Adjustable parameters
Opening pressure: 0 ... 40 MPa (0.4)
Pressure regulation range: 0.01 ... 10 MPa (0.15)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.06)
Adjustable parameters
Opening pressure: 0 ... 40 MPa (0.4)
Pressure regulation range: 0.01 ... 10 MPa (0.15)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.06)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 387
Pressure compensator, downstream
Adjustable parameters
Opening pressure: 0 ... 40 MPa (0.02)
Pressure regulation range: 0.01 ... 10 MPa (0.018)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.058)
Adjustable parameters
Opening pressure: 0 ... 40 MPa (0.02)
Pressure regulation range: 0.01 ... 10 MPa (0.018)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.058)
Adjustable parameters
Opening pressure: 0 ... 40 MPa (0.4)
Pressure regulation range: 0.01 ... 10 MPa (0.15)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.058)
388 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Pressure compensator for open centre load sensing
Adjustable parameters
Opening pressure: 0 ... 40 MPa (0.4)
Pressure regulation range: 0.01 ... 10 MPa (0.15)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.058)
Adjustable parameters
Maximum pressure: 0 ... 40 MPa (1.5)
Displacement (Left group): -100 ... 100 % (0)
Displacement (Right group): -100 ... 100 % (0)
Adjustable parameters
Opening pressure (Left group): 0 ... 40 MPa (3)
Pressure regulation range (Left group): 0.01 ... 10 MPa (3.8)
Hydraulic resistance (Left group): 1e-6 ... 1000 bar.min2/l2 (0.08)
Opening pressure (Right group): 0 ... 40 MPa (3)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 389
Pressure regulation range (Right group): 0.01 ... 10 MPa (3.8)
Hydraulic resistance (Right group): 1e-6 ... 1000 bar.min2/l2
(0.08)
Adjustable parameters
Nominal pressure: 0 ... 40 MPa (1)
Pressure regulation range: 0.01 ... 10 MPa (0.2)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.1)
Adjustable parameters
Nominal pressure: 0 ... 40 MPa (1)
Pressure regulation range: 0.01 ... 10 MPa (0.2)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.1)
390 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Opening pressure compensator
Adjustable parameters
Nominal pressure: 0 ... 40 MPa (1)
Pressure regulation range: 0.01 ... 10 MPa (0.2)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.1)
Adjustable parameters
Nominal pressure: 0 ... 40 MPa (1)
Pressure regulation range: 0.01 ... 10 MPa (0.2)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.1)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 391
the effective areas A, B and X, the adjacent pressures pA, pB and
pX, as well as the spring force. A+B=X is valid. If pA*A + pB*B >
pX*X + F, then the valve opens, otherwise it is closed. The valve
therefore operates purely pressure dependent and can, with the
appropriate control, assume directional-, flow- and pressure func-
tions. The spring force is specified by means of the nominal pres-
sure. This is the minimum pressure, with pressureless connections
at B and X, necessary at connection A to open the valve. Whether
the valve has one (A=B) or two (A <> B) effective areas can be speci-
fied in the properties window. The relevant symbol is automatically
depicted. The hydraulic resistance relates to the completely opened
valve.
Adjustable parameters
Opening pressure: 0 ... 40 MPa (0.5)
Area A: 0.1 ... 100 cm2 (6)
Area B: 0.1 ... 100 cm2 (3)
Pressure regulation range: 0.01 ... 10 MPa (0.05)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.01)
Adjustable parameters
Opening pressure: 0 ... 40 MPa (0.5)
Area: 0.1 ... 100 cm2 (6)
Pressure regulation range: 0.01 ... 10 MPa (0.05)
392 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.01)
The pressure switch takes the pressure and actuates the associat-
ed electrical pressure switch if the preset switching pressure is
exceeded.
Adjustable parameters
Switching pressure: -0.1 ... 40 MPa (3)
Hysteresis: 0 ... 10 MPa (0)
Nozzle
Adjustable parameters
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.19)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 393
Throttle valve
Adjustable parameters
Opening level: 0 ... 100 % (100)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.19)
Orifice
Adjustable parameters
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.19)
Orifice, adjustable
Adjustable parameters
Opening level: 0 ... 100 % (100)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.19)
394 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
resistance value can be set. This means that, in reality, different
throttle valves can generate different resistance values despite
identical settings.
Adjustable parameters
Opening level: 0 ... 100 % (100)
Hydraulic resistance (Flow control valve): 1e-6 ... 1000
bar.min2/l2 (0.07)
Hydraulic resistance (Non-return valve): 1e-6 ... 1000 bar.min2/l2
(0.05)
Adjustable parameters
Nominal flow: 0 ... 500 l/min (1)
Spring preload: 0 ... 10 MPa (0.6)
Pressure regulation range: 0.01 ... 10 MPa (0.05)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.3)
Adjustable parameters
Nominal flow: 0 ... 500 l/min (1)
Spring preload: 0 ... 10 MPa (0.45)
Pressure regulation range: 0.01 ... 10 MPa (0.05)
Hydraulic resistance (Flow control valve): 1e-6 ... 1000
bar.min2/l2 (0.4)
Hydraulic resistance (Non-return valve): 1e-6 ... 1000 bar.min2/l2
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 395
(0.08)
With sufficient pressure, the preset flow rate is kept constant in the
direction of the arrow. The surplus hydraulic fluid is drained at
connection T using a pressure compensator. The inlet pressure pA
is load dependent, i.e it changes with the outlet pressure pB. There-
fore a parallel circuit of several 3-way flow control valves is not
possible. In this case, the inlet pressures would be defined by the
valve with the lowest inlet pressure. Compared to the 2-way flow
control valve, the 3-way flow control valve is admittedly more
efficient in its energy consumption. The hydraulic resistance relates
to the completely closed pressure compensator.
Adjustable parameters
Nominal flow: 0 ... 500 l/min (1)
Spring preload: 0 ... 10 MPa (0.5)
Pressure regulation range: 0.01 ... 10 MPa (0.05)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.4)
The flow divider valve divides the flow from P into two equal flows
at A and B. This is achieved using two measuring orifices and two
variable control resistors. The control resistors are unified in a
pressure compensator. The hydraulic resistance relates to the
resistance of the individual measuring orifices and control resis-
tors.
Adjustable parameters
Hydraulic resistance (Pressure compensator): 1e-6 ... 1000
bar.min2/l2 (0.375)
Hydraulic resistance (Metering orifice): 1e-6 ... 1000 bar.min2/l2
(0.537)
396 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Flush valve with pressure relief valve
If differential pressure exceeds the required force for the spring, the
valve opens from B to the pressure-relief valve.
Adjustable parameters
Spring preload: 0 ... 40 MPa (0.25)
Hydraulic resistance (Directional valve): 1e-6 ... 1000 bar.min2/l2
(0.08)
Opening pressure: 0 ... 40 MPa (0.5)
Hydraulic resistance (Pressure control valve): 1e-6 ... 1000
bar.min2/l2 (0.08)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 397
leading edge as appropriate. The overlap of the leading edges can
be specified relative to the maximal slide distance. By the use of an
integrated electronic position controller for the slide distance,
beneficial static and dynamic characteristics are achieved that are
manifested in a minimal hysteresis (less than 0,2 %) and a re-
sponse time of less than 12 ms at a signal change of 0 - 100
Adjustable parameters
Control notch shape: Rectangular, Triangular (Rectangular)
Relative spool overlap: -50 ... 50 % (0)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (1.4)
Leakage: 0 ... 10 l/(min.bar) (0.00026)
Adjustable parameters
Control notch shape: Rectangular, Triangular (Triangular)
Relative spool overlap: -50 ... 50 % (25)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (3.2)
Leakage: 0 ... 10 l/(min.bar) (0.001)
398 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Proportional throttle valve
In order to alter the flow rate through the valve, the cross section of
the throttle valve is electrically manipulated with the assistance of
a proportional amplifier. The control voltage must be between 0 V
and 10 V. The deflection of the slide is proportional to the applied
voltage. At 0 V the valve is completely closed (in relation to the null
overlap). The hydraulic resistance relates to the completely opened
valve. The overlap of the leading edges can be specified relative to
the maximal slide distance.
Adjustable parameters
Control notch shape: Rectangular, Triangular (Triangular)
Relative spool overlap: -50 ... 50 % (0)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.1)
Leakage: 0 ... 10 l/(min.bar) (0)
Adjustable parameters
Min. Opening pressure: 0 ... 40 MPa (0)
Max. Opening pressure: 0 ... 40 MPa (10)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 399
Pressure regulation range: 0.01 ... 10 MPa (2)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.1)
Adjustable parameters
Min. Opening pressure: 0 ... 40 MPa (0)
Max. Opening pressure: 0 ... 40 MPa (10)
Pressure regulation range: 0.01 ... 10 MPa (2)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.05)
400 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
the electrically adjustable counter force with the assistance of a
proportional amplifier. If the pressure at connection A is below the
preset value, then the pilot control remains closed. The pressure on
both sides of the control slide valve is equal. A spring holds the
main stage control slide valve open and the hydraulic fluid flow
freely from connection P to connection A. If the pressure at connec-
tion A exceeds the preset value, then the pilot stage opens causing
less volumetric flow to flow to connection A. The pressure falls at
the throttle valve inside the control slide valve. Thus the pressure
at the spring side is lower than the pressure at connection A. Due to
the pressure difference, the control slide valve closes so far until
the spring force re-establishes an equilibrium of forces. As a result,
the flow resistance at the control edge between connections P and
A increases and the pressure at connection A sinks. The control
voltage must be between 0 V and 10 V. The minimum nominal
pressure defines the opening pressure at the pre stage via the
spring force at 0 V. The maximum nominal pressure defines the
opening pressure at 10 V. The hydraulic resistance relates to the
completely opened main stage leading edge.
Adjustable parameters
Min. Nominal pressure: 0 ... 40 MPa (0)
Max. Nominal pressure: 0 ... 40 MPa (3)
Pressure regulation range: 0.01 ... 10 MPa (0.1)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.05)
The valve is used to control volumetric flow. Flow rate and direction
of flow are controlled. The mid-position is spring centered. The
piston is pushed out of its mid-position and against the spring with
the hand lever.
Adjustable parameters
Displacement: -100 ... 100 % (0)
Hydraulic resistance (P1->T1): 1e-6 ... 1000 bar.min2/l2 (0.045)
Hydraulic resistance (P2->A,B): 1e-6 ... 1000 bar.min2/l2 (0.051)
Hydraulic resistance (T2->A,B): 1e-6 ... 1000 bar.min2/l2 (0.0362)
Leakage: 0 ... 10 l/(min.bar) (5E-06)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 401
Mobile valve block, Load sensing
The valve block has two slices, each with a proportional directional
control valve for controlling speed and direction. The directional
control valve in each slice has an upstream pressure compensator.
As a result, the slice functions like a proportional current regulator.
Adjustable parameters
Displacement (Left group): -100 ... 100 % (0)
Displacement (Right group): -100 ... 100 % (0)
21.1.10 Actuators
Configurable cylinder
Adjustable parameters
402 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Piston diameter: 1 ... 1000 mm (16)
Piston rod diameter: 0 ... 1000 mm (10)
Piston Position: 0 ... 5000 mm (0)
Maximum stroke: 1 ... 5000 mm (200)
Mounting angle: 0 ... 360 deg (0)
Parameter input: Calculate automatically, Enter manually (Calcu-
late automatically)
Break-away force: 0 ... 10000 N (65)
Coulomb friction force: 0 ... 10000 N (55)
Viscous friction: 0.1 ... 10000 N.s/m (215)
Parameter input: Calculate automatically, Enter manually (Calcu-
late automatically)
Moving mass: 0.01 ... 1000 kg (0.3)
Leakage: 0 ... 10 l/(min.bar) (0)
Spring pressure at x=0: 0 ... 40 MPa (0.4)
Spring pressure at x=x_max: 0 ... 40 MPa (1)
Damping length: 0 ... 100 mm (10)
Double acting cylinder with piston rod on one side. The piston of
the cylinder contains a permanent solenoid which can be used to
operate a proximity switch.
Adjustable parameters
Piston diameter: 1 ... 1000 mm (16)
Piston rod diameter: 0 ... 1000 mm (10)
Piston Position: 0 ... 5000 mm (0)
Maximum stroke: 1 ... 5000 mm (200)
Mounting angle: 0 ... 360 deg (0)
Parameter input: Calculate automatically, Enter manually (Calcu-
late automatically)
Break-away force: 0 ... 10000 N (65)
Coulomb friction force: 0 ... 10000 N (55)
Viscous friction: 0.1 ... 10000 N.s/m (215)
Parameter input: Calculate automatically, Enter manually (Calcu-
late automatically)
Moving mass: 0.01 ... 1000 kg (0.3)
Leakage: 0 ... 10 l/(min.bar) (0)
Spring pressure at x=0: 0 ... 40 MPa (0.4)
Spring pressure at x=x_max: 0 ... 40 MPa (1)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 403
Damping length: 0 ... 100 mm (10)
Adjustable parameters
Piston diameter: 1 ... 1000 mm (16)
Piston rod diameter: 0 ... 1000 mm (10)
Piston Position: 0 ... 5000 mm (0)
Maximum stroke: 1 ... 5000 mm (200)
Mounting angle: 0 ... 360 deg (0)
Parameter input: Calculate automatically, Enter manually (Calcu-
late automatically)
Break-away force: 0 ... 10000 N (65)
Coulomb friction force: 0 ... 10000 N (55)
Viscous friction: 0.1 ... 10000 N.s/m (215)
Parameter input: Calculate automatically, Enter manually (Calcu-
late automatically)
Moving mass: 0.01 ... 1000 kg (0.3)
Leakage: 0 ... 10 l/(min.bar) (0)
Spring pressure at x=0: 0 ... 40 MPa (0.4)
Spring pressure at x=x_max: 0 ... 40 MPa (1)
Damping length: 0 ... 100 mm (10)
Double acting cylinder with in and out piston rod and shock
adsorber at stroke end
Adjustable parameters
404 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Piston diameter: 1 ... 1000 mm (16)
Piston rod diameter: 0 ... 1000 mm (10)
Piston Position: 0 ... 5000 mm (0)
Maximum stroke: 1 ... 5000 mm (200)
Mounting angle: 0 ... 360 deg (0)
Parameter input: Calculate automatically, Enter manually (Calcu-
late automatically)
Break-away force: 0 ... 10000 N (65)
Coulomb friction force: 0 ... 10000 N (55)
Viscous friction: 0.1 ... 10000 N.s/m (215)
Parameter input: Calculate automatically, Enter manually (Calcu-
late automatically)
Moving mass: 0.01 ... 1000 kg (0.3)
Leakage: 0 ... 10 l/(min.bar) (0)
Spring pressure at x=0: 0 ... 40 MPa (0.4)
Spring pressure at x=x_max: 0 ... 40 MPa (1)
Damping length: 0 ... 100 mm (10)
Adjustable parameters
Piston diameter: 1 ... 1000 mm (16)
Piston rod diameter: 0 ... 1000 mm (10)
Piston Position: 0 ... 5000 mm (0)
Maximum stroke: 1 ... 5000 mm (200)
Mounting angle: 0 ... 360 deg (0)
Parameter input: Calculate automatically, Enter manually (Calcu-
late automatically)
Break-away force: 0 ... 10000 N (65)
Coulomb friction force: 0 ... 10000 N (55)
Viscous friction: 0.1 ... 10000 N.s/m (215)
Parameter input: Calculate automatically, Enter manually (Calcu-
late automatically)
Moving mass: 0.01 ... 1000 kg (0.3)
Leakage: 0 ... 10 l/(min.bar) (0)
Spring pressure at x=0: 0 ... 40 MPa (0.4)
Spring pressure at x=x_max: 0 ... 40 MPa (1)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 405
Damping length: 0 ... 100 mm (10)
Adjustable parameters
Piston diameter: 1 ... 1000 mm (16)
Piston rod diameter: 1 ... 1000 mm (10)
Piston Position: 0 ... 5000 mm (0)
Maximum stroke: 1 ... 10000 mm (200)
Mounting angle: 0 ... 360 deg (0)
Moving mass: 0.01 ... 1000 kg (0.6)
Opening pressure: 0 ... 40 MPa (12)
Break-away force: 0 ... 10000 N (65)
Coulomb friction force: 0 ... 10000 N (55)
Viscous friction: 0.1 ... 10000 N.s/m (215)
Adjustable parameters
Piston diameter: 1 ... 1000 mm (16)
Piston rod diameter: 1 ... 1000 mm (10)
Piston Position: 0 ... 5000 mm (0)
Maximum stroke: 1 ... 10000 mm (200)
Mounting angle: 0 ... 360 deg (0)
Moving mass: 0.01 ... 1000 kg (0.6)
Break-away force: 0 ... 10000 N (65)
Coulomb friction force: 0 ... 10000 N (55)
Viscous friction: 0.1 ... 10000 N.s/m (215)
406 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Hydraulic motor
Adjustable parameters
External torque: -1000 ... 1000 N.m (0)
Displacement: 0.001 ... 5 l (0.008)
Friction: 0.001 ... 100 N.m.s/rad (0.0108)
Moment of inertia: 0.0001 ... 10 kg.m2 (0.0001)
Leakage: 0 ... 10 l/(min.bar) (0.0126)
Semi-rotary actuator
Adjustable parameters
Initial Position: 0 ... 360 deg (0)
Rotation angle (max): 1 ... 360 deg (180)
Displacement: 0.01 ... 1000 l (0.1)
Friction: 0.01 ... 100 N.m.s/rad (0.1)
Moment of inertia: 1e-005 ... 1 kg.m2 (0.0001)
External torque: -1000 ... 1000 N.m (0)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 407
21.1.11 Measuring Devices
Manometer
Pressure indicator
Adjustable parameters
Switching pressure: -0.1 ... 40 MPa (3)
Adjustable parameters
408 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Minimum pressure: -40 ... 40 MPa (0)
Maximum pressure: -40 ... 40 MPa (10)
Voltage at p1: -100 ... 100 V (0)
Voltage at p2: -100 ... 100 V (10)
Flow meter
The flow meter measures the flow rate. Either the current flow or
the total quantity flowed can be displayed. The component image is
automatically adjusted accordingly.
Adjustable parameters
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.001)
Flow meter
Adjustable parameters
Displacement: 0.1 ... 5000 cm3 (8.2)
Friction: 0.001 ... 100 N.m.s/rad (0.0108)
Moment of inertia: 0.0001 ... 10 kg.m2 (0.0001)
Leakage: 0 ... 10 l/(min.bar) (0.0126)
Flow Direction: Ignore, Consider (Ignore)
Flow rate (min): -500 ... 500 l/min (0)
Flow rate (max): -500 ... 500 l/min (10)
Voltage (q1): -100 ... 100 V (0)
Voltage (q2): -100 ... 100 V (10)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 409
Flow meter, analog
This symbol represents the hydraulic part of the analog flow meter.
The analog flow meter measures the volumetric flow and trans-
forms it into a proportional electrical voltage signal. In the process,
only flow rates in the specified pressure ranges are considered.
Within this range, the flow rate in the voltage range from 0 V to 10 V
is represented, i.e. the minimum volumetric flow delivers 0 V and
the maximum volumetric flow 10 V.
Adjustable parameters
Flow Direction: Ignore, Consider (Ignore)
Flow rate (min): -500 ... 500 l/min (0)
Flow rate (max): -500 ... 500 l/min (10)
Voltage (q1): -100 ... 100 V (0)
Voltage (q2): -100 ... 100 V (10)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.001)
Adjustable parameters
410 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Operating pressure: 0 ... 2 MPa (0.6)
Max. flow rate: 0 ... 5000 l/min (1000)
Volume: 0.001 ... 1000 l (0.1)
Compressor
Adjustable parameters
Operating pressure: 0 ... 2 MPa (0.6)
Max. flow rate: 0 ... 5000 l/min (1000)
Volume: 0.001 ... 1000 l (0.1)
Compressor, adjustable
Adjustable parameters
Operating pressure: 0 ... 2 MPa (0.6)
Max. flow rate: 0 ... 5000 l/min (1000)
Volume: 0.001 ... 1000 l (0.1)
Adjustable parameters
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 411
Nominal pressure: 0 ... 2 MPa (0.4)
Standard nominal flow rate (Pressure regulator): 0.1 ... 5000
l/min (300)
Standard nominal flow rate (Filter): 0.1 ... 5000 l/min (1000)
Adjustable parameters
Nominal pressure: 0 ... 2 MPa (0.4)
Standard nominal flow rate (Pressure regulator): 0.1 ... 5000
l/min (300)
Standard nominal flow rate (Filter): 0.1 ... 5000 l/min (1000)
The filter with water separator cleans the compressed air of dirt,
pipe scale, rust and condensate. The pressure regulator adjusts the
compressed air supplied to the set operating pressure and com-
pensates for pressure fluctuations. The pressure gauge shows the
preset pressure. The on/off valve exhausts the entire control.
Manifold
412 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Air pressure reservoir
Adjustable parameters
Volume: 0.001 ... 1000 l (1)
Adjustable parameters
Volume: 0.001 ... 1000 l (1)
Filter
Adjustable parameters
Standard nominal flow rate: 0.1 ... 5000 l/min (1000)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 413
Filter, manual condensate drain
Adjustable parameters
Standard nominal flow rate: 0.1 ... 5000 l/min (1000)
Adjustable parameters
Standard nominal flow rate: 0.1 ... 5000 l/min (1000)
Water separator
Adjustable parameters
Standard nominal flow rate: 0.1 ... 5000 l/min (1000)
414 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Water separator, automatic condensate drain
Adjustable parameters
Standard nominal flow rate: 0.1 ... 5000 l/min (1000)
Lubricator
Adjustable parameters
Standard nominal flow rate: 0.1 ... 5000 l/min (1000)
Cooler
Adjustable parameters
Standard nominal flow rate: 0.1 ... 5000 l/min (1000)
Adsorption dryer
Adjustable parameters
Standard nominal flow rate: 0.1 ... 5000 l/min (1000)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 415
Connection (pneumatic)
Line (pneumatic)
Adjustable parameters
Physical model: Ideal connection,Simple resistance, Empirical
model (Ideal connection)
Length: 0.01 ... 1000 m (0.5)
Inner diameter: 0.1 ... 100 mm (2.5)
Standard nominal flow rate: 0.1 ... 5000 l/min (500)
T-junction (pneumatic)
416 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
21.2.2 Configurable Way Valves
The configurable 2/n way valve is a way valve with two connec-
tions, where both its body elements operation modes are user-
definable.
Adjustable parameters
Desired position: 0 ... 4 (0)
Standard nominal flow rate: 0.1 ... 5000 l/min (60)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
air spring left: 0.01 ... 100 cm2 (0.5)
air spring right: 0.01 ... 100 cm2 (0.5)
The configurable 3/n way valve is a way valve with two connec-
tions, where both its body elements operation modes are user-
definable.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 417
Additionally, the pneumatic connections can be closed with either
blind plugs or exhausts.
Adjustable parameters
Desired position: 0 ... 4 (0)
Standard nominal flow rate: 0.1 ... 5000 l/min (60)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
air spring left: 0.01 ... 100 cm2 (0.5)
air spring right: 0.01 ... 100 cm2 (0.5)
The configurable 4/n way valve is a way valve with two connec-
tions, where both its body elements operation modes are user-
definable.
Adjustable parameters
Desired position: 0 ... 4 (0)
Standard nominal flow rate: 0.1 ... 5000 l/min (60)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
418 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
air spring left: 0.01 ... 100 cm2 (0.5)
air spring right: 0.01 ... 100 cm2 (0.5)
The configurable 5/n way valve is a way valve with two connec-
tions, where both its body elements operation modes are user-
definable.
Adjustable parameters
Desired position: 0 ... 4 (0)
Standard nominal flow rate: 0.1 ... 5000 l/min (60)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
air spring left: 0.01 ... 100 cm2 (0.5)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 419
air spring right: 0.01 ... 100 cm2 (0.5)
The configurable 6/n way valve is a way valve with two connec-
tions, where both its body elements operation modes are user-
definable.
Adjustable parameters
Desired position: 0 ... 4 (0)
Standard nominal flow rate: 0.1 ... 5000 l/min (60)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
air spring left: 0.01 ... 100 cm2 (0.5)
air spring right: 0.01 ... 100 cm2 (0.5)
The configurable 8/n way valve is a way valve with two connec-
tions, where both its body elements operation modes are user-
definable.
420 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Additionally, the pneumatic connections can be closed with either
blind plugs or exhausts.
Adjustable parameters
Desired position: 0 ... 4 (0)
Standard nominal flow rate: 0.1 ... 5000 l/min (60)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
air spring left: 0.01 ... 100 cm2 (0.5)
air spring right: 0.01 ... 100 cm2 (0.5)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 421
urable 3/n way valve. You find this valve in the component library
Frequently used Way Valves, under the Library menu.
Adjustable parameters
Desired position: 0 ... 4 (0)
Standard nominal flow rate: 0.1 ... 5000 l/min (60)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
air spring left: 0.01 ... 100 cm2 (0.5)
air spring right: 0.01 ... 100 cm2 (0.5)
Adjustable parameters
Desired position: 0 ... 4 (0)
Standard nominal flow rate: 0.1 ... 5000 l/min (60)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
422 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
air spring left: 0.01 ... 100 cm2 (0.5)
air spring right: 0.01 ... 100 cm2 (0.5)
The idle return roller valve is operated when the roller is driven in a
specific direction by the switching cam of a cylinder. After releasing
the roller, the valve returns to its initial position through the use of
a return spring. Connection 1 is shut. When the roller is driven in
the opposite direction, the valve is not operated. In the Simulation
Mode, the valve can be switched manually by clicking on the com-
ponent, thus not requiring a cylinder to operate the valve. This
valve is derived from a configurable 3/n way valve. You find this
valve in the component library Frequently used Way Valves,
under the Library menu.
Adjustable parameters
Desired position: 0 ... 4 (0)
Standard nominal flow rate: 0.1 ... 5000 l/min (60)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 423
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
air spring left: 0.01 ... 100 cm2 (0.5)
air spring right: 0.01 ... 100 cm2 (0.5)
Pressurizing valve
Adjustable parameters
Desired position: 0 ... 4 (0)
Standard nominal flow rate: 0.1 ... 5000 l/min (60)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
air spring left: 0.01 ... 100 cm2 (0.5)
air spring right: 0.01 ... 100 cm2 (0.5)
424 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Pneumatic proximity switch, solenoid operated
Adjustable parameters
Desired position: 0 ... 4 (0)
Standard nominal flow rate: 0.1 ... 5000 l/min (60)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
air spring left: 0.01 ... 100 cm2 (0.5)
air spring right: 0.01 ... 100 cm2 (0.5)
Pressing the pushbutton operates the valve. The flow passes freely
from 1 to 2. Releasing the pushbutton allows the valve to return to
its starting position through the use of a return spring. Connection
1 is shut. By holding down the Shift key and simultaneously
clicking on the component with the mouse cursor, FluidSIM keeps
the valve in permanent operating position. Simply clicking on the
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 425
component cancels the operated state and returns the valve to its
starting position. This valve is derived from a configurable 3/n way
valve. You find this valve in the component library Frequently used
Way Valves, under the Library menu.
Adjustable parameters
Desired position: 0 ... 4 (0)
Standard nominal flow rate: 0.1 ... 5000 l/min (60)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
air spring left: 0.01 ... 100 cm2 (0.5)
air spring right: 0.01 ... 100 cm2 (0.5)
Adjustable parameters
426 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Desired position: 0 ... 4 (0)
Standard nominal flow rate: 0.1 ... 5000 l/min (60)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
air spring left: 0.01 ... 100 cm2 (0.5)
air spring right: 0.01 ... 100 cm2 (0.5)
Pressing the red striking button operates the valve. The flow passes
freely from 1 to 2. Releasing the button has no effect; the valve
remains in its operating position. Turning the button to the right
sets the striking button back to its original position and the valve
returns to its starting position through the use of a return spring.
Connection 1 is shut. This valve is derived from a configurable 3/n
way valve. You find this valve in the component library Frequently
used Way Valves, under the Library menu.
Adjustable parameters
Desired position: 0 ... 4 (0)
Standard nominal flow rate: 0.1 ... 5000 l/min (60)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 427
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
air spring left: 0.01 ... 100 cm2 (0.5)
air spring right: 0.01 ... 100 cm2 (0.5)
Turning the selection switch operates the valve. The flow passes
freely from 1 to 4. Releasing the switch has no effect; the valve
remains in its operating position. Turning the switch back to its
original position allows the flow to pass freely from 1 to 2. This
valve is derived from a configurable 5/n way valve. You find this
valve in the component library Frequently used Way Valves,
under the Library menu.
Adjustable parameters
Desired position: 0 ... 4 (0)
Standard nominal flow rate: 0.1 ... 5000 l/min (60)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
air spring left: 0.01 ... 100 cm2 (0.5)
air spring right: 0.01 ... 100 cm2 (0.5)
428 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
21.2.4 Solenoid Operated Directional Valves
Adjustable parameters
Desired position: 0 ... 4 (0)
Standard nominal flow rate: 0.1 ... 5000 l/min (60)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
air spring left: 0.01 ... 100 cm2 (0.5)
air spring right: 0.01 ... 100 cm2 (0.5)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 429
3/2-way solenoid valve, normally open
Adjustable parameters
Desired position: 0 ... 4 (0)
Standard nominal flow rate: 0.1 ... 5000 l/min (60)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
air spring left: 0.01 ... 100 cm2 (0.5)
air spring right: 0.01 ... 100 cm2 (0.5)
430 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
the component library Frequently used Way Valves, under the
Library menu.
Adjustable parameters
Desired position: 0 ... 4 (0)
Standard nominal flow rate: 0.1 ... 5000 l/min (60)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
air spring left: 0.01 ... 100 cm2 (0.5)
air spring right: 0.01 ... 100 cm2 (0.5)
Adjustable parameters
Desired position: 0 ... 4 (0)
Standard nominal flow rate: 0.1 ... 5000 l/min (60)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 431
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
air spring left: 0.01 ... 100 cm2 (0.5)
air spring right: 0.01 ... 100 cm2 (0.5)
Adjustable parameters
Desired position: 0 ... 4 (0)
Standard nominal flow rate: 0.1 ... 5000 l/min (60)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
432 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
air spring left: 0.01 ... 100 cm2 (0.5)
air spring right: 0.01 ... 100 cm2 (0.5)
Adjustable parameters
Desired position: 0 ... 4 (0)
Standard nominal flow rate: 0.1 ... 5000 l/min (60)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
air spring left: 0.01 ... 100 cm2 (0.5)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 433
air spring right: 0.01 ... 100 cm2 (0.5)
Adjustable parameters
Desired position: 0 ... 4 (0)
Standard nominal flow rate: 0.1 ... 5000 l/min (60)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
air spring left: 0.01 ... 100 cm2 (0.5)
air spring right: 0.01 ... 100 cm2 (0.5)
434 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
derived from a configurable 5/n way valve. You find this valve in
the component library Frequently used Way Valves, under the
Library menu.
Adjustable parameters
Desired position: 0 ... 4 (0)
Standard nominal flow rate: 0.1 ... 5000 l/min (60)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
air spring left: 0.01 ... 100 cm2 (0.5)
air spring right: 0.01 ... 100 cm2 (0.5)
Adjustable parameters
Desired position: 0 ... 4 (0)
Standard nominal flow rate: 0.1 ... 5000 l/min (60)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 435
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
air spring left: 0.01 ... 100 cm2 (0.5)
air spring right: 0.01 ... 100 cm2 (0.5)
Adjustable parameters
Desired position: 0 ... 4 (0)
Standard nominal flow rate: 0.1 ... 5000 l/min (60)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
436 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Pilot control right: 0.01 ... 100 cm2 (1)
air spring left: 0.01 ... 100 cm2 (0.5)
air spring right: 0.01 ... 100 cm2 (0.5)
Each of the two double-level low pressure amplifier units has the
function of a 3/2 directional valve that is normally closed. The
signal at connection 12 is raised to a higher boost pressure level
through the use of a double-level amplifier and is put out by con-
nection 2.
Adjustable parameters
Standard nominal flow rate: 0.1 ... 5000 l/min (60)
Shuttle valve
Adjustable parameters
Standard nominal flow rate: 0.1 ... 5000 l/min (108)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 437
Quick exhaust valve
Adjustable parameters
Standard nominal flow rate 1...2: 0.1 ... 5000 l/min (300)
Standard nominal flow rate 2...3: 0.1 ... 5000 l/min (550)
Adjustable parameters
Standard nominal flow rate: 0.1 ... 5000 l/min (550)
Check valve
Adjustable parameters
Standard nominal flow rate: 0.1 ... 5000 l/min (108)
438 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Check valve, spring loaded
Adjustable parameters
Opening pressure: 0 ... 2 MPa (0.1)
Pressure regulation range: 0.01 ... 1 MPa (0.05)
Standard nominal flow rate: 0.1 ... 5000 l/min (108)
Adjustable parameters
Area ratio: 0.1 ... 10 (3.3)
Standard nominal flow rate: 0.1 ... 5000 l/min (108)
Adjustable parameters
Opening pressure: 0 ... 2 MPa (0.1)
Pressure regulation range: 0.01 ... 1 MPa (0.05)
Area ratio: 0.1 ... 10 (3.3)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 439
Standard nominal flow rate: 0.1 ... 5000 l/min (108)
Adjustable parameters
Area ratio: 0.1 ... 10 (3.3)
Standard nominal flow rate: 0.1 ... 5000 l/min (108)
Adjustable parameters
Opening pressure: 0 ... 2 MPa (0.1)
Pressure regulation range: 0.01 ... 1 MPa (0.05)
Area ratio: 0.1 ... 10 (3.3)
Standard nominal flow rate: 0.1 ... 5000 l/min (108)
Nozzle
Adjustable parameters
Standard nominal flow rate: 0.1 ... 5000 l/min (100)
440 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Throttle valve
Adjustable parameters
Opening level: 0 ... 100 % (100)
Standard nominal flow rate: 0.1 ... 5000 l/min (100)
Orifice
Adjustable parameters
Standard nominal flow rate: 0.1 ... 5000 l/min (100)
Orifice, adjustable
Adjustable parameters
Opening level: 0 ... 100 % (100)
Standard nominal flow rate: 0.1 ... 5000 l/min (100)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 441
cross-section of the throttle is adjustable via a regular screw. In the
opposite direction the flow can pass through the check valve.
Adjustable parameters
Opening level: 0 ... 100 % (100)
Standard nominal flow rate (Flow control valve): 0.1 ... 5000 l/min
(45)
Standard nominal flow rate (Non-return valve): 0.1 ... 5000 l/min
(65)
Pneumatic counter
Adjustable parameters
Counter: 0 ... 9999 (3)
Standard nominal flow rate: 0.1 ... 5000 l/min (60)
Adjustable parameters
Delay time: 0.1 ... 100 s (3)
Standard nominal flow rate: 0.1 ... 5000 l/min (50)
442 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Time delay valve, normally open
After the pilot signal is applied at port 10, a preset time elapses
before the pneumatic timer is actuated. It returns to its initial
position via a return spring once the signal is removed. The time
delay is infinitely adjustable by means of a regulating screw. The
time delay is reset automatically within 200 ms.
Adjustable parameters
Delay time: 0.1 ... 100 s (3)
Standard nominal flow rate: 0.1 ... 5000 l/min (50)
Ring sensor
Adjustable parameters
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 443
Nominal pressure: 0 ... 2 MPa (0.4)
Pressure regulation range: 0.01 ... 1 MPa (0.05)
Standard nominal flow rate: 0.1 ... 5000 l/min (300)
Adjustable parameters
Nominal pressure: 0 ... 2 MPa (0.4)
Pressure regulation range: 0.01 ... 1 MPa (0.05)
Standard nominal flow rate: 0.1 ... 5000 l/min (300)
Adjustable parameters
Nominal pressure: 0 ... 2 MPa (0.4)
Pressure regulation range: 0.01 ... 1 MPa (0.05)
Standard nominal flow rate: 0.1 ... 5000 l/min (300)
444 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
the real components is component dependent and cannot be
changed.
Adjustable parameters
Nominal pressure: 0 ... 2 MPa (0.4)
Pressure regulation range: 0.01 ... 1 MPa (0.05)
Standard nominal flow rate: 0.1 ... 5000 l/min (300)
Adjustable parameters
Nominal pressure: 0 ... 2 MPa (0.4)
Pressure regulation range: 0.01 ... 1 MPa (0.05)
Standard nominal flow rate: 0.1 ... 5000 l/min (300)
Adjustable parameters
Nominal pressure: 0 ... 2 MPa (0.4)
Pressure regulation range: 0.01 ... 1 MPa (0.05)
Standard nominal flow rate: 0.1 ... 5000 l/min (300)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 445
Closing pressure compensator, adjustable
Adjustable parameters
Nominal pressure: 0 ... 2 MPa (0.4)
Pressure regulation range: 0.01 ... 1 MPa (0.05)
Standard nominal flow rate: 0.1 ... 5000 l/min (300)
Adjustable parameters
Nominal pressure: 0 ... 2 MPa (0.4)
Pressure regulation range: 0.01 ... 1 MPa (0.05)
Standard nominal flow rate: 0.1 ... 5000 l/min (300)
446 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Adjustable parameters
Nominal pressure: 0 ... 2 MPa (0.4)
Pressure regulation range: 0.01 ... 1 MPa (0.05)
Standard nominal flow rate: 0.1 ... 5000 l/min (300)
Adjustable parameters
Switching pressure: -0.1 ... 2 MPa (0.3)
Hysteresis: 0 ... 1 MPa (0)
Vacuum switch
The vacuum switch operates the linked pressure switch, when the
pressure falls below the adjustable switching pressure. If the sym-
bol is used as a pressure switch the respective switch is operated
when the pressure exceeds the switching pressure.
Adjustable parameters
Switching pressure: -0.1 ... 2 MPa (0.3)
Hysteresis: 0 ... 1 MPa (0)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 447
Differential pressure switch
Adjustable parameters
Switching pressure: -2 ... 2 MPa (0.3)
Hysteresis: 0 ... 1 MPa (0)
The vacuum suction nozzle creates its vacuum based on the ejector
principle. In this case, compressed air flows from connection 1 to 3,
creating a vacuum at connection 1v. A sucker can be connected to
the vacuum connection 1v. Stopping the input of compressed air at
connection 1 stops any suction also.
Adjustable parameters
Maximum vacuum: -0.999 ... 0 bar (-0.85)
Operating pressure for max. vacuum: 0.1 ... 20 bar (4.25)
Air consumption at 600 kPa: 1 ... 1000 l/min (11.6)
Max. suction rate: 0.1 ... 1000 l/min (6)
448 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Vacuum suction nozzle
The vacuum suction nozzle creates its vacuum based on the ejector
principle. In this case, compressed air flows from connection 1 to 3,
creating a vacuum at connection 1v. A sucker can be connected to
the vacuum connection 1v. Stopping the input of compressed air at
connection 1 stops any suction also.
Adjustable parameters
Maximum vacuum: -0.999 ... 0 bar (-0.85)
Operating pressure for max. vacuum: 0.1 ... 20 bar (4.25)
Air consumption at 600 kPa: 1 ... 1000 l/min (11.6)
Max. suction rate: 0.1 ... 1000 l/min (6)
Adjustable parameters
Maximum vacuum: -0.999 ... 0 bar (-0.85)
Operating pressure for max. vacuum: 0.1 ... 20 bar (4.25)
Air consumption at 600 kPa: 1 ... 1000 l/min (11.6)
Max. suction rate: 0.1 ... 1000 l/min (6)
Volume: 0.001 ... 10 l (0.05)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 449
Suction cup
The suction cup can be used together with the vacuum suction
nozzle to grip objects by suction. Lowering the cup onto an object
is simulated in FluidSIM in Simulation Mode by clicking on the
component. An additional click lifts the suction cup.
Adjustable parameters
Diameter: 1 ... 1000 mm (20)
Load to be lifted: 0.001 ... 1000 kg (0.1)
Safety factor: 0.1 ... 100 (1)
Adjustable parameters
Min. spring pressure: 0 ... 1 bar (0.1)
Max. Spring pressure: 0.01 ... 1 bar (0.2)
Min. Flow rate at p1-p2 = 50 kPa: 0.001 ... 1000 l/min (0.5)
Max. Flow rate at p1-p2 = 50 kPa: 0.1 ... 1000 l/min (4)
450 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Adjustable vacuum actuator valve
Adjustable parameters
Switching pressure: -0.1 ... 0 MPa (-0.025)
Standard nominal flow rate: 0.1 ... 5000 l/min (100)
Adjustable parameters
Switching pressure: 0 ... 20 bar (3)
Standard nominal flow rate: 0.1 ... 5000 l/min (100)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 451
When the necessary pressure is reached at the control connection
12 of the unit, the 3/2-way valve switches and the flow passes
freely from 1 to 2.
Adjustable parameters
Opening level: 0 ... 100 % (100)
Standard nominal flow rate (Flow control valve): 0.1 ... 5000 l/min
(10)
Volume: 0.001 ... 100 l (0.01)
Standard nominal flow rate (Directional valve): 0.1 ... 5000 l/min
(50)
Adjustable parameters
Opening level: 0 ... 100 % (100)
Standard nominal flow rate (Flow control valve): 0.1 ... 5000 l/min
(10)
Volume: 0.001 ... 100 l (0.01)
Standard nominal flow rate (Directional valve): 0.1 ... 5000 l/min
(50)
Adjustable parameters
Initial Position: Left, Right (Left)
Desired position: 0 ... 2 (0)
452 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Standard nominal flow rate: 0.1 ... 5000 l/min (60)
Adjustable parameters
Initial Position: Left, Right (Right)
Desired position: 0 ... 2 (0)
Standard nominal flow rate: 0.1 ... 5000 l/min (60)
Quickstepper
The control block for two-hand start ZSB is a pneumatic AND ele-
ment. If the inputs 11 and 12 are pressurized within max. 0.5 s one
after the other, the ZSB will switch through: an output signal is
present at port 2. Control takes place via two external 3/2-way
pushbutton valves. As long as both pushbutton valves are activat-
ed, outlet port 2 is pressurized. If one or both pushbuttons are
released, outlet port 2 is unpressurized. The system exhausts from
2 to 3.
Adjustable parameters
Opening level: 0 ... 100 % (100)
Standard nominal flow rate: 0.1 ... 5000 l/min (100)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 453
21.2.11 Continuous valves
Adjustable parameters
Standard nominal flow rate: 0.1 ... 5000 l/min (773)
21.2.12 Actuators
Configurable cylinder
454 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
possible. An end position cushioning (without, with, adjustable)
can also be defined. FluidSIM automatically adjusts the symbol
according to the preset configuration. In addition, a load to be
moved (including possible static and sliding friction) and a variable
force profile can be defined in the properties dialog. In the compo-
nent library of FluidSIM there are several pre-configured cylinders
that can be inserted in your circuit and directly used. Should no
suitable symbol be available, then simply choose the component
with the most similarity to the required component, open the prop-
erties dialog and adjust the configuration accordingly.
Adjustable parameters
Piston diameter: 1 ... 1000 mm (20)
Piston rod diameter: 0 ... 1000 mm (8)
Piston Position: 0 ... 5000 mm (0)
Maximum stroke: 1 ... 5000 mm (200)
Mounting angle: 0 ... 360 deg (0)
Parameter input: Calculate automatically, Enter manually (Calcu-
late automatically)
Reference pressure: 0.1 ... 20 bar (6)
Reference velocity: 0.1 ... 2 m/s (1)
Friction at dp_ref: 1 ... 5000 N (120)
Break-away force at dp_ref: 1 ... 5000 N (12)
Parameter input: Calculate automatically, Enter manually (Calcu-
late automatically)
Moving mass: 0.01 ... 1000 kg (0.3)
Leakage: 0 ... 10 l/(min.bar) (0)
Spring pressure at x=0: 0 ... 10 MPa (0.5)
Spring pressure at x=x_max: 0 ... 10 MPa (1)
Damping length: 1 ... 100 mm (10)
Adjustable parameters
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 455
Piston diameter: 1 ... 1000 mm (20)
Piston rod diameter: 0 ... 1000 mm (8)
Piston Position: 0 ... 5000 mm (0)
Maximum stroke: 1 ... 5000 mm (200)
Mounting angle: 0 ... 360 deg (0)
Parameter input: Calculate automatically, Enter manually (Calcu-
late automatically)
Reference pressure: 0.1 ... 20 bar (6)
Reference velocity: 0.1 ... 2 m/s (1)
Friction at dp_ref: 1 ... 5000 N (120)
Break-away force at dp_ref: 1 ... 5000 N (12)
Parameter input: Calculate automatically, Enter manually (Calcu-
late automatically)
Moving mass: 0.01 ... 1000 kg (0.3)
Leakage: 0 ... 10 l/(min.bar) (0)
Spring pressure at x=0: 0 ... 10 MPa (0.5)
Spring pressure at x=x_max: 0 ... 10 MPa (1)
Damping length: 1 ... 100 mm (10)
Adjustable parameters
Piston diameter: 1 ... 1000 mm (20)
Piston rod diameter: 0 ... 1000 mm (8)
Piston Position: 0 ... 5000 mm (0)
Maximum stroke: 1 ... 5000 mm (200)
Mounting angle: 0 ... 360 deg (0)
Parameter input: Calculate automatically, Enter manually (Calcu-
late automatically)
Reference pressure: 0.1 ... 20 bar (6)
Reference velocity: 0.1 ... 2 m/s (1)
Friction at dp_ref: 1 ... 5000 N (120)
Break-away force at dp_ref: 1 ... 5000 N (12)
Parameter input: Calculate automatically, Enter manually (Calcu-
late automatically)
Moving mass: 0.01 ... 1000 kg (0.3)
456 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Leakage: 0 ... 10 l/(min.bar) (0)
Spring pressure at x=0: 0 ... 10 MPa (0.5)
Spring pressure at x=x_max: 0 ... 10 MPa (1)
Damping length: 1 ... 100 mm (10)
Adjustable parameters
Piston diameter: 1 ... 1000 mm (20)
Piston rod diameter: 0 ... 1000 mm (8)
Piston Position: 0 ... 5000 mm (0)
Maximum stroke: 1 ... 5000 mm (200)
Mounting angle: 0 ... 360 deg (0)
Parameter input: Calculate automatically, Enter manually (Calcu-
late automatically)
Reference pressure: 0.1 ... 20 bar (6)
Reference velocity: 0.1 ... 2 m/s (1)
Friction at dp_ref: 1 ... 5000 N (120)
Break-away force at dp_ref: 1 ... 5000 N (12)
Parameter input: Calculate automatically, Enter manually (Calcu-
late automatically)
Moving mass: 0.01 ... 1000 kg (0.3)
Leakage: 0 ... 10 l/(min.bar) (0)
Spring pressure at x=0: 0 ... 10 MPa (0.5)
Spring pressure at x=x_max: 0 ... 10 MPa (1)
Damping length: 1 ... 100 mm (10)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 457
The in and out piston rod of the double acting cylinder is controlled
by alternating the compressed air input. The cushioning can be
adapted with two adjustment screws.
Adjustable parameters
Piston diameter: 1 ... 1000 mm (20)
Piston rod diameter: 0 ... 1000 mm (8)
Piston Position: 0 ... 5000 mm (0)
Maximum stroke: 1 ... 5000 mm (200)
Mounting angle: 0 ... 360 deg (0)
Parameter input: Calculate automatically, Enter manually (Calcu-
late automatically)
Reference pressure: 0.1 ... 20 bar (6)
Reference velocity: 0.1 ... 2 m/s (1)
Friction at dp_ref: 1 ... 5000 N (120)
Break-away force at dp_ref: 1 ... 5000 N (12)
Parameter input: Calculate automatically, Enter manually (Calcu-
late automatically)
Moving mass: 0.01 ... 1000 kg (0.3)
Leakage: 0 ... 10 l/(min.bar) (0)
Spring pressure at x=0: 0 ... 10 MPa (0.5)
Spring pressure at x=x_max: 0 ... 10 MPa (1)
Damping length: 1 ... 100 mm (10)
Double acting cylinder with two in and out piston rods and single
trestle.
This twin cylinder has two in and out piston rods that move in
parallel and that are coupled by a trestle. The construction guaran-
tees minimum torsion when positioning and moving tools or as-
semblies. Moreover, coming along with the same construction
height, the double piston rod conveys the double force as com-
pared to standard cylinders.
Adjustable parameters
Piston diameter: 1 ... 1000 mm (20)
Piston rod diameter: 0 ... 1000 mm (8)
Piston Position: 0 ... 5000 mm (0)
Maximum stroke: 1 ... 5000 mm (200)
Mounting angle: 0 ... 360 deg (0)
458 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Parameter input: Calculate automatically, Enter manually (Calcu-
late automatically)
Reference pressure: 0.1 ... 20 bar (6)
Reference velocity: 0.1 ... 2 m/s (1)
Friction at dp_ref: 1 ... 5000 N (120)
Break-away force at dp_ref: 1 ... 5000 N (12)
Parameter input: Calculate automatically, Enter manually (Calcu-
late automatically)
Moving mass: 0.01 ... 1000 kg (0.3)
Leakage: 0 ... 10 l/(min.bar) (0)
Spring pressure at x=0: 0 ... 10 MPa (0.5)
Spring pressure at x=x_max: 0 ... 10 MPa (1)
Damping length: 1 ... 100 mm (10)
Double acting cylinder with two in and out piston rods and double
trestle.
This twin cylinder has two in and out piston rods that move in
parallel and that are coupled by a double trestle. The construction
guarantees minimum torsion when positioning and moving tools or
assemblies. Moreover, coming along with the same construction
height, the double piston rod conveys the double force as com-
pared to standard cylinders.
Adjustable parameters
Piston diameter: 1 ... 1000 mm (20)
Piston rod diameter: 0 ... 1000 mm (8)
Piston Position: 0 ... 5000 mm (0)
Maximum stroke: 1 ... 5000 mm (200)
Mounting angle: 0 ... 360 deg (0)
Parameter input: Calculate automatically, Enter manually (Calcu-
late automatically)
Reference pressure: 0.1 ... 20 bar (6)
Reference velocity: 0.1 ... 2 m/s (1)
Friction at dp_ref: 1 ... 5000 N (120)
Break-away force at dp_ref: 1 ... 5000 N (12)
Parameter input: Calculate automatically, Enter manually (Calcu-
late automatically)
Moving mass: 0.01 ... 1000 kg (0.3)
Leakage: 0 ... 10 l/(min.bar) (0)
Spring pressure at x=0: 0 ... 10 MPa (0.5)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 459
Spring pressure at x=x_max: 0 ... 10 MPa (1)
Damping length: 1 ... 100 mm (10)
Adjustable parameters
Piston diameter: 1 ... 1000 mm (20)
Piston rod diameter: 1 ... 1000 mm (8)
Total stroke: 1 ... 2000 mm (200)
Piston Position: 0 ... 2000 mm (0)
Intermediate position: 0 ... 1000 mm (0)
External force: -10000 ... 10000 N (0)
Adjustable parameters
Piston diameter: 1 ... 1000 mm (20)
Piston rod diameter: 0 ... 1000 mm (8)
Piston Position: 0 ... 5000 mm (0)
Maximum stroke: 1 ... 5000 mm (200)
Mounting angle: 0 ... 360 deg (0)
Parameter input: Calculate automatically, Enter manually (Calcu-
late automatically)
Reference pressure: 0.1 ... 20 bar (6)
Reference velocity: 0.1 ... 2 m/s (1)
Friction at dp_ref: 1 ... 5000 N (120)
460 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Break-away force at dp_ref: 1 ... 5000 N (12)
Parameter input: Calculate automatically, Enter manually (Calcu-
late automatically)
Moving mass: 0.01 ... 1000 kg (0.3)
Leakage: 0 ... 10 l/(min.bar) (0)
Spring pressure at x=0: 0 ... 10 MPa (0.5)
Spring pressure at x=x_max: 0 ... 10 MPa (1)
Damping length: 1 ... 100 mm (10)
Adjustable parameters
Piston diameter: 1 ... 1000 mm (20)
Piston rod diameter: 0 ... 1000 mm (8)
Piston Position: 0 ... 5000 mm (0)
Maximum stroke: 1 ... 5000 mm (200)
Mounting angle: 0 ... 360 deg (0)
Parameter input: Calculate automatically, Enter manually (Calcu-
late automatically)
Reference pressure: 0.1 ... 20 bar (6)
Reference velocity: 0.1 ... 2 m/s (1)
Friction at dp_ref: 1 ... 5000 N (120)
Break-away force at dp_ref: 1 ... 5000 N (12)
Parameter input: Calculate automatically, Enter manually (Calcu-
late automatically)
Moving mass: 0.01 ... 1000 kg (0.3)
Leakage: 0 ... 10 l/(min.bar) (0)
Spring pressure at x=0: 0 ... 10 MPa (0.5)
Spring pressure at x=x_max: 0 ... 10 MPa (1)
Damping length: 1 ... 100 mm (10)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 461
Pneumatic linear drive with shape-fitting adaptor
Adjustable parameters
Piston diameter: 1 ... 1000 mm (20)
Piston rod diameter: 0 ... 1000 mm (8)
Piston Position: 0 ... 5000 mm (0)
Maximum stroke: 1 ... 5000 mm (200)
Mounting angle: 0 ... 360 deg (0)
Parameter input: Calculate automatically, Enter manually (Calcu-
late automatically)
Reference pressure: 0.1 ... 20 bar (6)
Reference velocity: 0.1 ... 2 m/s (1)
Friction at dp_ref: 1 ... 5000 N (120)
Break-away force at dp_ref: 1 ... 5000 N (12)
Parameter input: Calculate automatically, Enter manually (Calcu-
late automatically)
Moving mass: 0.01 ... 1000 kg (0.3)
Leakage: 0 ... 10 l/(min.bar) (0)
Spring pressure at x=0: 0 ... 10 MPa (0.5)
Spring pressure at x=x_max: 0 ... 10 MPa (1)
Damping length: 1 ... 100 mm (10)
Air motor
Adjustable parameters
External torque: -1000 ... 1000 N.m (0)
Displacement: 0.001 ... 5 l (0.1)
Friction: 0.001 ... 100 N.m.s/rad (3)
Moment of inertia: 0.0001 ... 10 kg.m2 (0.0001)
462 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Semi-Rotary actuator
Adjustable parameters
Initial Position: 0 ... 360 deg (0)
Rotation angle (max): 1 ... 360 deg (180)
Displacement: 0.01 ... 1000 l (0.1)
Friction: 0.01 ... 100 N.m.s/rad (0.1)
Moment of inertia: 1e-005 ... 1 kg.m2 (0.0001)
External torque: -1000 ... 1000 N.m (0)
Manometer
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 463
Pressure indicator
Adjustable parameters
Switching pressure: -0.1 ... 2 MPa (0.3)
Adjustable parameters
Minimum pressure: -2 ... 2 MPa (0)
Maximum pressure: -2 ... 2 MPa (1)
Voltage at p1: -100 ... 100 V (0)
Voltage at p2: -100 ... 100 V (10)
Adjustable parameters
Minimum pressure: -2 ... 2 MPa (0)
Maximum pressure: -2 ... 2 MPa (1)
Voltage at p1: -100 ... 100 V (0)
Voltage at p2: -100 ... 100 V (10)
464 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Flow meter
The flow meter measures the flow rate. Either the current flow or
the total quantity flowed can be displayed. The component image is
automatically adjusted accordingly.
Adjustable parameters
Standard nominal flow rate: 0.1 ... 5000 l/min (100)
Flow meter
The flow meter measures the flow rate. Either the current flow or
the total quantity flowed can be displayed. The component image is
automatically adjusted accordingly.
Adjustable parameters
Standard nominal flow rate: 0.1 ... 5000 l/min (100)
Adjustable parameters
Flow Direction: Ignore, Consider (Ignore)
Flow rate (min): -500 ... 500 l/min (0)
Flow rate (max): -500 ... 500 l/min (1000)
Voltage (q1): -100 ... 100 V (0)
Voltage (q2): -100 ... 100 V (10)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 465
Standard nominal flow rate: 0.1 ... 5000 l/min (2000)
Adjustable parameters
Output function: Make switch,Break switch (Make switch)
Switching function: Threshold value,Window comparator
(Threshold value)
Switching pressure 1: -0.1 ... 2 MPa (0.3)
Switching pressure 2: -0.1 ... 2 MPa (1)
Hysteresis: 0 ... 2 MPa (0)
Minimum voltage: 1 ... 300 V (13)
Idle current (24 V): 1 ... 10000 mA (32)
Adjustable parameters
466 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Output function: Make switch,Break switch (Make switch)
Switching function: Threshold value,Window comparator
(Threshold value)
Switching pressure 1: -0.1 ... 2 MPa (0.3)
Switching pressure 2: -0.1 ... 2 MPa (1)
Hysteresis: 0 ... 2 MPa (0)
Minimum pressure: -0.1 ... 2 MPa (0)
Maximum pressure: -0.1 ... 2 MPa (1)
Voltage at p1: -100 ... 100 V (0)
Voltage at p2: -100 ... 100 V (10)
Minimum voltage: 1 ... 300 V (13)
Idle current (24 V): 1 ... 10000 mA (32)
Flow sensor
The flow sensor is used to measure and monitor flow rate and air
consumption values. Measurement is carried out by means of a
thermal procedure, whereby the amount of heat drawn from a
heated surface of the sensor by the medium flowing past it is
calculated. The flow rate or the accumulated air consumption is
based on the amount of heat drawn.
Adjustable parameters
Output function: Make switch,Break switch (Make switch)
Switching function: Threshold value,Window comparator
(Threshold value)
Switching point 1 (Flow rate): -5000 ... 5000 l/min (10)
Switching point 2 (Flow rate): -5000 ... 5000 l/min (20)
Hysteresis (Flow rate): 0 ... 5000 l/min (0)
Switching point 1 (Volume): 0 ... 100000 l (100)
Switching point 2 (Volume): 0 ... 100000 l (200)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 467
Hysteresis (Volume): 0 ... 10000 l (0)
Min. Flow rate: -5000 ... 5000 l/min (0)
Max. Flow rate: -5000 ... 5000 l/min (100)
Voltage at q1: -100 ... 100 V (0)
Voltage at q2: -100 ... 100 V (10)
Minimum voltage: 1 ... 300 V (12)
Idle current (24 V): 1 ... 10000 mA (32)
Electrical connection 0V
Adjustable parameters
Voltage: 0 ... 400 V (0)
Adjustable parameters
Voltage: 0 ... 400 V (24)
468 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Function generator
Adjustable parameters
Signal type: Rectangle, Sine, Triangle, Constant, Profile (Sine)
Frequency: 0.01 ... 100000 Hz (1)
Amplitude: 0 ... 400 V (5)
y offset: -100 ... 100 V (0)
Min. Voltage: -400 ... 400 V (-30)
Max. Voltage: -400 ... 400 V (30)
Function generator
Adjustable parameters
Signal type: Rectangle, Sine, Triangle, Constant, Profile (Sine)
Frequency: 0.01 ... 100000 Hz (1)
Amplitude: 0 ... 400 V (5)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 469
y offset: -100 ... 100 V (0)
Min. Voltage: -400 ... 400 V (-30)
Max. Voltage: -400 ... 400 V (30)
470 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Connection (electrical)
Line (electrical)
T-junction (electrical)
DC motor
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 471
Adjustable parameters
External torque: 0 ... 20 N.m (0)
Idle revolution: 10 ... 20000 1/min (75)
Solenoid
Adjustable parameters
Resistance: 1 ... 10000 Ohm (20)
Indicator light
Adjustable parameters
Resistance: 0.01 ... 1E4 Ohm (193.5)
Minimum voltage: 0.1 ... 300 V (5)
Buzzer
Adjustable parameters
472 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Resistance: 0.01 ... 1E4 Ohm (100)
Minimum voltage: 0.1 ... 300 V (5)
Voltmeter
Adjustable parameters
Measure mode: Instantaneous value,Effective (RMS) voltage
(Instantaneous value)
Time interval: 0.001 ... 100 s (0.1)
Resistance: 1E-3 ... 10 MOhm (1)
Ammeter
Adjustable parameters
Measure mode: Instantaneous value,Effective (RMS) current
(Instantaneous value)
Time interval: 0.001 ... 100 s (0.1)
Resistance: 1e-006 ... 1 Ohm (1E-6)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 473
Displacement encoder
Adjustable parameters
Voltage (Cylinder retracted): -10 ... 10 V (0)
Voltage (Cylinder extracted): -10 ... 10 V (10)
Minimum voltage: 0.1 ... 300 V (13)
Resistance: 1 ... 10000 Ohm (100)
474 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Flow meter, analog
Position transmitter
Adjustable parameters
Voltage (Cylinder retracted): -100 ... 100 V (2)
Voltage (Cylinder extracted): -100 ... 100 V (10)
Current (Cylinder retracted): -10000 ... 10000 mA (4)
Current (Cylinder extracted): -10000 ... 10000 mA (20)
Minimum voltage: 1 ... 300 V (15)
Idle current (24 V): 1 ... 10000 mA (32)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 475
Signal converter
Adjustable parameters
Output function: Make switch,Break switch (Make switch)
Switching function: Threshold value,Window comparator
(Threshold value)
Switching point 1: -100 ... 100 V (1)
Switching point 2: -100 ... 100 V (8)
Hysteresis: 0 ... 100 V (0)
Switching time: 1e-5 ... 10 s (0.001)
Minimum voltage: 1 ... 300 V (15)
Idle current (24 V): 1 ... 10000 mA (32)
Break switch
476 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Make switch
Changeover switch
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 477
Changeover switch (switch-on delayed)
478 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
21.3.6 Limit Switches
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 479
Switch with roll (make)
480 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Reed contact (changeover)
Pushbutton (break)
Pushbutton (make)
Pushbutton (changeover)
Switch that changes over when actuated and changes back imme-
diately when released. In FluidSIM switches can be actuated per-
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 481
manently (locked) when continuing to hold down the mouse button
and pushing the Shift - key. This permanent actuation is released
by a simple click on the component.
482 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
switches are created by using a general break switch and setting a
label.
The switch closes when the preset switching pressure of the pneu-
matic or hydraulic pressure switch is exceeded. Pressure switches
are created by using a general make switch and setting a label.
The switch changes over when the preset switching pressure of the
pneumatic or hydraulic pressure switch is exceeded. Pressure
switches are created by using a general changeover switch and
setting a label.
Pressure switch
Pressure switch
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 483
21.3.9 Proximity Switches
484 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
21.3.10 Relay
Relay
Adjustable parameters
Resistance: 1 ... 10000 Ohm (550)
Minimum voltage: 0.1 ... 300 V (20)
The relay picks up after a preset time when current is supplied and
drops out immediately when current is removed.
Adjustable parameters
Delay time: 0 ... 999 s (5)
Resistance: 1 ... 10000 Ohm (550)
Minimum voltage: 0.1 ... 300 V (20)
Adjustable parameters
Delay time: 0 ... 999 s (5)
Resistance: 1 ... 10000 Ohm (550)
Minimum voltage: 0.1 ... 300 V (20)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 485
Relay counter
Adjustable parameters
Counter: 0 ... 9999 (5)
Resistance: 1 ... 10000 Ohm (550)
Minimum voltage: 0.1 ... 300 V (20)
Adjustable parameters
Duration: 1 ... 10000 ms (0.05)
Current limit: 0.01 ... 100 A (2)
486 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
21.3.11 Controller
Comparator
Adjustable parameters
Set value voltage: -300 ... 300 V (5)
Hysteresis: 0 ... 100 V (0)
Minimum voltage: 0.1 ... 300 V (13)
Resistance: 1 ... 10000 Ohm (100)
PID controller
Adjustable parameters
Range selection: -10 .. 10 V,0 .. 10 V (-10 .. 10 V)
Proportional gain: 0 ... 1000 (1)
Integral gain: 0 ... 1000 1/s (0)
Derivation gain: 0 ... 1000 ms (0)
Control quantity offset: -7 ... 7 V (0)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 487
Status controller
Adjustable parameters
Range selection: -10 .. 10 V,0 .. 10 V (-10 .. 10 V)
Deviation gain: 0 ... 10 (1)
Velocity damping: 0 ... 100 ms (0)
Acceleration damping: 0 ... 10 ms2 (0)
Total gain: 0 ... 1000 (1)
Control quantity offset: -7 ... 7 V (0)
488 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
21.3.12 EasyPort/OPC/DDE Components
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 489
Multi-pin plug distributor
Universal-I/O
490 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
21.4 Electrical Components (American Standard)
Adjustable parameters
Voltage: 0 ... 400 V (0)
Adjustable parameters
Voltage: 0 ... 400 V (24)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 491
linked via a label to a switch-off delay relay, the break switch
changes to a switch-off delay break switch in the circuit diagram.
492 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Make switch (switch-off delayed, ladder)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 493
Limit switch (make, ladder)
494 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Pushbutton (make, ladder)
Switch that changes over when actuated and changes back imme-
diately when released. In FluidSIM switches can be actuated per-
manently (locked) when continuing to hold down the mouse button
and pushing the Shift key. This permanent actuation is released
by a simple click on the component.
The switch closes when the preset switching pressure of the pneu-
matic or hydraulic pressure switch is exceeded. Pressure switches
are created by using a general make switch and setting a label.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 495
21.4.7 Relays
Relay
Adjustable parameters
Resistance: 1 ... 10000 Ohm (550)
Minimum voltage: 0.1 ... 300 V (20)
The relay picks up after a preset time when current is supplied and
drops out immediately when current is removed.
Adjustable parameters
Delay time: 0 ... 999 s (5)
Resistance: 1 ... 10000 Ohm (550)
Minimum voltage: 0.1 ... 300 V (20)
Adjustable parameters
Delay time: 0 ... 999 s (5)
Resistance: 1 ... 10000 Ohm (550)
Minimum voltage: 0.1 ... 300 V (20)
496 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
21.5 Electronic components
Adjustable parameters
Voltage: 0 ... 400 V (12)
Potential
Adjustable parameters
Voltage: -400 ... 400 V (5)
Ground
The ground symbol defines the 0 V reference potential for all signal
and operating voltages.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 497
Three-phase alternator
Adjustable parameters
Frequency: 0.01 ... 1000 Hz (50)
String voltage: 0 ... 400 V (7)
Connector panel
DC power supply
Adjustable parameters
Effective (RMS) voltage (min): 10 ... 400 V (90)
AC Frequency (min): 10 ... 100 Hz (30)
Voltage (DC): 0 ... 400 V (12)
Efficiency: 0.1 ... 1 (0.9)
498 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
DC power supply
L1
Adjustable parameters
Effective (RMS) voltage: 0 ... 400 V (230)
Frequency: 1 ... 100 Hz (50)
Phase shift: 0 ... 360 deg (0)
L2
Adjustable parameters
Effective (RMS) voltage: 0 ... 400 V (230)
Frequency: 1 ... 100 Hz (50)
Phase shift: 0 ... 360 deg (120)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 499
L3
Adjustable parameters
Effective (RMS) voltage: 0 ... 400 V (230)
Frequency: 1 ... 100 Hz (50)
Phase shift: 0 ... 360 deg (240)
Neutral conductor
PE
Resistor
Adjustable parameters
Resistance: 1e-6 ... 1E8 Ohm (100)
500 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Resistor, temperature-dependent (NTC)
Adjustable parameters
Reference Resistance: 1 ... 1E6 Ohm (5208)
Reference temperature: 0 ... 100 C (23)
Adjustable parameters
Light intensity: 0 ... 100 % (50)
Min. Resistance: 1 ... 1E6 Ohm (183)
Max. Resistance: 1 ... 1E6 Ohm (34324)
Potentiometer
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 501
Adjustable parameters
Potentiometer position: 0 ... 100 % (0)
Resistance: 1E-4 ... 100000 kOhm (1)
Capacitor
Adjustable parameters
Capacity: 1E-4 ... 1E7 uF (1)
Capacitor, polarized
502 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
If a constant voltage is applied to the connectors of an uncharged
capacitor, a current flows for a short period of time and one of the
electrodes is positively charged, the other one negatively. This
electric charge is retained when the capacitor is disconnected from
the voltage source. If charge resp. electric flow is extracted from the
capacitor, its voltage drops again.
Adjustable parameters
Capacity: 1E-4 ... 1E7 uF (1)
Inductor
Adjustable parameters
Inductance: 1E-3 ... 1E4 mH (100)
Transformer
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 503
the ratio of the number of windings of the corresponding coils to
each other.
Adjustable parameters
Inductance 1: 1E-3 ... 1E4 mH (595)
Inductance 2: 1E-3 ... 1E4 mH (66)
Coupling coefficient: 0 ... 1 (1)
21.5.3 Semiconductor
Diode
Adjustable parameters
Reference voltage: 0.1 ... 100 V (0.7)
Reference current: 1 ... 1000 mA (12.6)
Resistance in series: 0.001 ... 1000 Ohm (0.0341512)
Saturation current: 1e-15 ... 100 A (7.02767e-9)
504 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
To make the use of the LED as a simple signal indicator easier,
FluidSIM allows setting the color independent of the physical
characteristics.
Adjustable parameters
Reference voltage: 0.1 ... 100 V (2)
Reference current: 1 ... 1000 mA (25)
Resistance in series : 0.001 ... 1000 Ohm (12.5)
Saturation current: 1e-15 ... 100 A (1e-12)
Adjustable parameters
Reference voltage: 0.1 ... 100 V (2.2)
Reference current: 1 ... 1000 mA (30)
Resistance in series : 0.001 ... 1000 Ohm (12.5)
Saturation current: 1e-15 ... 100 A (1e-12)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 505
To make the use of the LED as a simple signal indicator easier,
FluidSIM allows setting the color independent of the physical
characteristics.
Adjustable parameters
Reference voltage: 0.1 ... 100 V (4)
Reference current: 1 ... 1000 mA (35)
Resistance in series : 0.001 ... 1000 Ohm (12.5)
Saturation current: 1e-15 ... 100 A (1e-12)
In this component, a green and a red LED with opposite polarity are
connected in parallel. Depending on the current direction either the
green or red LED lights up. Connected to alternating current with a
frequency higher than about 30 Hz, the human eye cannot recog-
nize the blinking and it seems as if both LEDs are lit simultaneously.
Adjustable parameters
Reference voltage: 0.1 ... 100 V (2)
Reference current: 1 ... 1000 mA (25)
Resistance in series : 0.001 ... 1000 Ohm (12.5)
Saturation current: 1e-15 ... 100 A (1e-12)
Zener diode
506 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
tain value, the so-called breakdown voltage. The voltage does not
increase by much after that, even if the electric current is increased.
Adjustable parameters
Reference voltage: 0.1 ... 100 V (0.7)
Reference current: 1 ... 10000 mA (9)
Saturation current: 1e-10 ... 100 A (1e-10)
Z-voltage: 0.1 ... 100 V (10)
Current at Z-voltage: 1 ... 10000 mA (15)
NPN transistor
There are two types of BJTs: NPN and PNP. The letters indicate the
order and doping type of the layers. Essentially, a BJT constitutes
two p-n junctions connected together in series (like that of a p-n
diode.) The three terminals are called collector (C), base (B) and
emitter (E).
Adjustable parameters
Forward current gain: 0.1 ... 1000 (120)
Reverse current gain: 0.1 ... 1000 (1)
Saturation current: 1e-16 ... 1e-3 A (8.81138e-14)
Forward early voltage: 1 ... 1000 V (64)
PNP transistor
There are two types of BJTs: NPN and PNP. The letters indicate the
order and doping type of the layers. Essentially, a BJT constitutes
two p-n junctions connected together in series (like that of a p-n
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 507
diode.) The three terminals are called collector (C), base (B) and
emitter (E).
Adjustable parameters
Forward current gain: 0.1 ... 1000 (230)
Reverse current gain: 0.1 ... 1000 (1)
Saturation current: 1e-16 ... 1e-3 A (8.81138e-14)
Forward early voltage: 1 ... 1000 V (64)
N-channel JFET
Adjustable parameters
Threshold voltage: -20 ... 0 V (-3)
Transconductance parameter: 1e-6 ... 1e-1 A/V2 (1.304e-3)
Channel-length modulation parameter: 1e-6 ... 1e-1 1/V (2.25e-3)
P-channel JFET
Adjustable parameters
Threshold voltage: 0 ... 20 V (2.5)
Transconductance parameter: 1e-6 ... 1e-1 A/V2 (1.271e-3)
508 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Channel-length modulation parameter: 1e-6 ... 1e-1 1/V (0.04)
N-channel MOSFET-Transistor
P-channel MOSFET
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 509
Unijunction transistor
Thyristor
DIAC
510 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
rises above a certain threshold voltage, it will switch through and
the p-n junction becomes conductive. Resistance will rise rapidly
again after the current that is flowing through the DIAC falls below a
certain value (the holding current.) This procedure is referred to as
resetting the DIAC.
TRIAC
A TRIAC has a control terminal G (gate) and two main terminals MT1
and MT2, where MT2 is usually directly connected to the casing. In
order to be able to use a single control terminal for both thyristors,
TRIACs contain two firing, or helper, thyristor junctions, so that it
can be flipped into the low-impedance state by using a positive and
negative control pulse.
Ohmmeter
Adjustable parameters
Voltage: 0.1 ... 9 V (9)
Series resistor: 1 ... 1000 kOhm (47)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 511
Oscilloscope
Adjustable parameters
Resistance: 1E-3 ... 10 MOhm (10)
Adjustable parameters
Time interval: 0.001 ... 100 s (0.1)
Wattmeter
512 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Adjustable parameters
Time interval: 0.001 ... 100 s (0.1)
21.5.5 Switches
Circuit breaker
The symbol for the circuit breaker shows the switch in its open
state. The circuit breaker is closed automatically when simulation
in FluidSIM is started, so that it doesnt have to be closed manually
for each simulation.
Adjustable parameters
Rated current: 0.1 ... 100 A (10)
Tripping characteristic: B,C (B)
Tripping temperature: 50 ... 150 C (80)
Multiple of nominal current: 1.5 ... 10 (2)
Tripping time: 0.1 ... 100 s (30)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 513
3-pole circuit breaker
The symbol for the circuit breaker shows the switch in its open
state. The circuit breaker is closed automatically when simulation
in FluidSIM is started, so that it doesnt have to be closed manually
for each simulation.
Adjustable parameters
Rated current: 0.1 ... 100 A (10)
Tripping characteristic: B,C (B)
Tripping temperature: 50 ... 150 C (80)
Multiple of nominal current: 1.5 ... 10 (2)
Tripping time: 0.1 ... 100 s (30)
514 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
motor circuit breaker has a 10 A tripping class. The thermal trigger
starts to trip as of an amperage of 1.2 times nominal current and
the electromagnetic trigger is tripped as of 7.2 times nominal
current. If overloading occurs in any single phase, all three phases
are interrupted when the circuit breaker is tripped. The circuit
breaker has to be closed manually after tripping.
The symbol for the motor circuit breaker shows the switch in its
open state. The circuit breaker is closed automatically when simu-
lation in FluidSIM is started, so that it doesnt have to be closed
manually for each simulation.
Adjustable parameters
Rated current: 0.1 ... 100 A (3)
Tripping temperature: 50 ... 150 C (80)
Adjustable parameters
Rated current: 0.1 ... 100 A (1)
Tripping temperature: 50 ... 150 C (80)
This type of safety relay is based on the safety switching device for
the emergency stop function and the safety door in Festo Didactics
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 515
equipment set TP 250, Safety in pneumatic systems. The PNOZ
S4 safety relay from Pilz is used in the equipment set. Correct
wiring of the safety switching device is described in the operating
instructions included with the PNOZ S4.
Adjustable parameters
Operating mode: Automatic/Manual start,Monitored reset with
falling edge,Monitored reset with rising edge (Automatic/Manual
start)
Min. Voltage: 0.1 ... 100 V (21.6)
21.5.6 Machines
Capacitor motor
516 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
The capacitor motors characteristic data (for example winding
resistances, inductances, number of pole pairs etc.) are automati-
cally ascertained in the background after entering the performance
data. Details can be found in the following separate section: Simu-
lation of rotating machines.
Adjustable parameters
Power: 0.001 ... 100 kW (0.25)
Revolution: 1 ... 30000 1/min (1400)
Voltage: 1 ... 10000 V (230)
Frequency: 30 ... 100 Hz (50)
Current: 0.1 ... 100 A (1.86)
Capacity (Starting capacitor): 0.1 ... 100 uF (25)
Capacity (Running capacitor): 0.1 ... 100 uF (10)
Direction of rotation: Left,Right (Right)
External torque: 0 ... 100 N.m (0)
Revolution (Switch): 1 ... 100000 1/min (1000)
Capacitor motor
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 517
ed here, for example. (The direction of rotation is usually reversed
via the connection. This can be selected with the connecting cable.)
Adjustable parameters
Power: 0.001 ... 100 kW (0.25)
Revolution: 1 ... 30000 1/min (1400)
Voltage: 1 ... 10000 V (230)
Frequency: 30 ... 100 Hz (50)
Current: 0.1 ... 100 A (1.86)
Capacity (Starting capacitor): 0.1 ... 100 uF (25)
Capacity (Running capacitor): 0.1 ... 100 uF (10)
External torque: 0 ... 100 N.m (0)
Revolution (Switch): 1 ... 100000 1/min (1000)
518 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
The inner wiring selected in the parameters determines how en-
tered machine performance data is interpreted in order to ascertain
the machines characteristics data such as winding resistances,
inductances, number of pole pairs etc. These characteristic ma-
chine data are ascertained automatically in the background after
the performance data have been entered. Details can be found in
the following separate section: Simulation of rotating machines. In
addition to the performance data, tightening torque and pull-out
torque can also be entered to the parameters as a ratio to nominal
torque. This makes it possible to specify the characteristic load
curve of an actual machine somewhat more accurately.
Adjustable parameters
Internal wiring: Star connection,Delta connection (Star connec-
tion)
Power: 0.001 ... 1000 kW (0.25)
Revolution: 1 ... 10000 1/min (1350)
Power factor cos : 0.1 ... 0.99 (0.78)
Line-to-line voltage: 1 ... 10000 V (400)
Phase current: 0.1 ... 100 A (0.77)
Frequency: 30 ... 100 Hz (50)
T_0 : T_N: 0.1 ... 10 (1.35)
T_B : T_N: 0.1 ... 10 (1.58)
External torque: 0 ... 100 N.m (0)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 519
test bench or a further motor can be connected here, for example.
(The direction of rotation is usually reversed via the connection.
This can be selected with the connecting cable.) The other electrical
terminals are used for connection to the electrical section of the
motor test bench.
Adjustable parameters
Internal wiring: Star connection,Delta connection (Star connec-
tion)
Power: 0.001 ... 1000 kW (0.25)
Revolution: 1 ... 10000 1/min (1350)
Power factor cos : 0.1 ... 0.99 (0.78)
Line-to-line voltage: 1 ... 10000 V (400)
Phase current: 0.1 ... 100 A (0.77)
Frequency: 30 ... 100 Hz (50)
T_0 : T_N: 0.1 ... 10 (1.35)
T_B : T_N: 0.1 ... 10 (1.58)
External torque: -0 ... 100 N.m (0)
520 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
next. A slotted, laminated rotor core is used. A cage made of die-
cast aluminum is inserted into the slots. The cage thus comprises a
system of short-circuited electrical conductors.
Adjustable parameters
Internal wiring: Star connection,Delta connection (Star connec-
tion)
Power: 0.001 ... 1000 kW (0.25)
Revolution: 1 ... 10000 1/min (1350)
Power factor cos : 0.1 ... 0.99 (0.78)
Line-to-line voltage: 1 ... 10000 V (400)
Phase current: 0.1 ... 100 A (0.77)
Frequency: 30 ... 100 Hz (50)
T_0 : T_N: 0.1 ... 10 (1.35)
T_B : T_N: 0.1 ... 10 (1.58)
External torque: 0 ... 100 N.m (0)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 521
3-phase squirrel-cage asynchronous motor
Adjustable parameters
Internal wiring: Star connection,Delta connection (Star connec-
tion)
Power: 0.001 ... 1000 kW (0.25)
Revolution: 1 ... 10000 1/min (1350)
Power factor cos : 0.1 ... 0.99 (0.78)
Line-to-line voltage: 1 ... 10000 V (400)
Phase current: 0.1 ... 100 A (0.77)
Frequency: 30 ... 100 Hz (50)
T_0 : T_N: 0.1 ... 10 (1.35)
522 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
T_B : T_N: 0.1 ... 10 (1.58)
External torque: 0 ... 100 N.m (0)
Synchronous motor
Adjustable parameters
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 523
Power: 0.001 ... 1000 kW (0.3)
Revolution: 1 ... 10000 1/min (1500)
Power factor cos : 0.1 ... 1 (0.97)
Line-to-line voltage: 1 ... 10000 V (400)
Phase current: 0.1 ... 100 A (0.66)
Frequency: 30 ... 100 Hz (50)
Voltage (Exciter, Max.): 1 ... 10000 V (150)
Current (Exciter, Max.): 0.1 ... 100 A (0.95)
I_f : I_f_max: 0.01 ... 1 (0.5)
External torque: 0 ... 100 N.m (0)
Synchronous motor
524 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
maximum excitation current 0.95 A * 0.5 = nominal excitation
current 0.475 A).
Adjustable parameters
Power: 0.001 ... 1000 kW (0.3)
Revolution: 1 ... 10000 1/min (1500)
Power factor cos : 0.1 ... 1 (0.97)
Line-to-line voltage: 1 ... 10000 V (400)
Phase current: 0.1 ... 100 A (0.66)
Frequency: 30 ... 100 Hz (50)
Voltage (Exciter, Max.): 1 ... 10000 V (150)
Current (Exciter, Max.): 0.1 ... 100 A (0.95)
I_f : I_f_max: 0.01 ... 1 (0.5)
External torque: 0 ... 100 N.m (0)
Universal motor
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 525
indicated as a ratio to nominal rotary speed with the parameter Idle
revolution : Rated speed. The absolute value of idling speed is
determined by multiplying nominal speed by the specified ratio
(e.g. nominal rotary speed 2000 rpm * 1.1 = idling speed 2200
rpm). The additional simulation value, Revolution (), is used to
read out average motor speed, so that design-related vibration due
to rotational speed is compensated for in the display in the case of
operation with alternating current.
Adjustable parameters
Characteristic data: Alternating current,Direct current (Alternating
current)
Power: 0.001 ... 1000 kW (0.2)
Revolution: 1 ... 30000 1/min (3000)
Voltage: 1 ... 10000 V (230)
Current: 0.1 ... 100 A (3)
Frequency: 30 ... 100 Hz (50)
U_N_AC : U_N_DC: 1 ... 10 (1.643)
n_0 : n_N: 1.001 ... 100 (1.46)
Direction of rotation: Left,Right (Right)
External torque: 0 ... 100 N.m (0)
Universal motor
526 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Terminal 1 is a rotary terminal mechanism. A motor test bench or a
further motor can be connected here, for example. (The direction of
rotation is usually reversed via the connection. This can be selected
with the connecting cable.)
Adjustable parameters
Characteristic data: Alternating current,Direct current (Alternating
current)
Power: 0.001 ... 1000 kW (0.2)
Revolution: 1 ... 30000 1/min (3000)
Voltage: 1 ... 10000 V (230)
Current: 0.1 ... 100 A (3)
Frequency: 30 ... 100 Hz (50)
U_N_AC : U_N_DC: 1 ... 10 (1.643)
n_0 : n_N: 1.001 ... 100 (1.46)
External torque: 0 ... 100 N.m (0)
DC permanent-magnet motor
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 527
or a further motor can be connected here, for example. (The direc-
tion of rotation is usually reversed via the connection. This can be
selected with the connecting cable.)
Adjustable parameters
Power: 0.001 ... 1000 kW (0.3)
Revolution: 1 ... 30000 1/min (2000)
Voltage: 1 ... 10000 V (220)
Current: 0.1 ... 100 A (1.8)
Inductance: 1e-6 ... 10 H (0.01)
n_0 : n_N: 1.001 ... 100 (1.1)
Direction of rotation: Left,Right (Right)
External torque: 0 ... 100 N.m (0)
528 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
these connections influences automatic calculation of winding
resistances. The desired performance values are only attained if the
motor is externally wired as specified in the parameters.
Adjustable parameters
Characteristic data: Shunt-wound machine,Series-wound machine
(Shunt-wound machine)
Power: 0.001 ... 1000 kW (0.3)
Revolution: 1 ... 30000 1/min (2000)
Voltage: 1 ... 10000 V (220)
Current: 0.1 ... 100 A (1.8)
Inductance (Armature): 1e-6 ... 10 H (0.01)
Voltage: 1 ... 10000 V (220)
Current: 0.1 ... 100 A (0.3)
Inductance (Exciter): 1e-6 ... 10 H (0.01)
n_0 : n_N: 1.001 ... 100 (1.1)
External torque: 0 ... 100 N.m (0)
DC series motor
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 529
absolute value of idling speed is determined by multiplying nominal
speed by the specified ratio (e.g. nominal rotary speed 2000 rpm *
1.1 = idling speed 2200 rpm).
Adjustable parameters
Power: 0.001 ... 1000 kW (0.3)
Revolution: 1 ... 30000 1/min (2000)
Voltage: 1 ... 10000 V (220)
Current: 0.1 ... 100 A (1.9)
n_0 : n_N: 1.001 ... 100 (1.7)
Direction of rotation: Left,Right (Right)
External torque: 0 ... 100 N.m (0)
Inductance (Armature): 1e-6 ... 10 H (0.001)
Inductance (Exciter): 1e-6 ... 10 H (0.001)
DC shunt motor
530 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Adjustable parameters
Power: 0.001 ... 1000 kW (0.3)
Revolution: 1 ... 30000 1/min (2000)
Voltage: 1 ... 10000 V (220)
Current: 0.1 ... 100 A (1.8)
Inductance (Armature): 1e-6 ... 10 H (0.001)
Voltage: 1 ... 10000 V (220)
Current: 0.1 ... 100 A (0.3)
Inductance (Exciter): 1e-6 ... 10 H (0.001)
n_0 : n_N: 1.001 ... 100 (1.1)
Direction of rotation: Left,Right (Right)
External torque: 0 ... 100 N.m (0)
The way in which the selected torque acts upon the connected
motor can be specified in the parameters of the motor test bench
under Controlled variable. Torque (braking) means that the select-
ed torque value acts upon the motor as friction or as reaction
torque in opposition to the motors torque. Torque (driving) means
that the motor test bench functions itself as a drive and applies the
corresponding torque to the connected axis of rotation. If a rota-
tional speed is specified, torque output or input is adjusted such
that the desired rotational speed is attained. With regard to the
regulation of rotational speed, maximum torque can be specified as
a separate parameter.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 531
This component represents the mechanical section of the motor
test bench from Festo Didactics equipment set TP 1410, Servo
brake and drive system.
Adjustable parameters
Controlled variable: Torque (braking),Torque (driving),Revolution
(Torque (braking))
Torque: -100 ... 100 N.m (0)
Revolution: 0 ... 30000 1/min (0)
Torque (max): 0.1 ... 100 N.m (10)
Moment of inertia: 1e-6 ... 10 kg.m2 (0.0001)
The Motor and terminals are used to connect the motors thermal
switch. Connect these two terminals to the motors M and termi-
nals. Input terminals L1, L2 and L3 at the top are used to connect
supply power. The motor is connected to output terminals L1, L2
and L3 at the bottom. The PE terminal is for the protective conduc-
tor.
Adjustable parameters
Time interval: 0.001 ... 100 s (0.1)
532 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
21.5.7 Controller
Summator
Adjustable parameters
y offset: -5 ... 5 V (0)
Efficiency: 0 ... 1 (0.9)
Minimum voltage: 0 ... 10 V (1.5)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 533
D element
Adjustable parameters
Derivation gain: 1 ... 1000 ms (2)
Time constant (PT1): 0.01 ... 100 ms (1)
Efficiency: 0 ... 1 (0.9)
Minimum voltage: 0 ... 10 V (1.5)
534 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
P element
Adjustable parameters
Proportional gain: 0 ... 1000 (1)
Efficiency: 0 ... 1 (0.9)
Minimum voltage: 0 ... 10 V (1.5)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 535
Hysteresis element
Adjustable parameters
Hysteresis: 0 ... 10 V (0)
Efficiency: 0 ... 1 (0.9)
Minimum voltage: 0 ... 10 V (1.5)
536 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
I element
Adjustable parameters
Integral gain: 1 ... 1000 1/s (100)
Efficiency: 0 ... 1 (0.9)
Minimum voltage: 0 ... 10 V (1.5)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 537
PT1 element
Adjustable parameters
Time: 0.001 ... 1 s (0.01)
Proportional gain: 0 ... 10 (1)
Efficiency: 0 ... 1 (0.9)
Minimum voltage: 0 ... 10 V (1.5)
538 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
PT2 element
Adjustable parameters
Time constant: 0.001 ... 1 s (0.01)
Proportional gain: 0 ... 10 (1)
Damping: 1e-5 ... 1000 s (1)
Efficiency: 0 ... 1 (0.9)
Minimum voltage: 0 ... 10 V (1.5)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 539
Differential amplifier
Adjustable parameters
Efficiency: 0 ... 1 (0.9)
Minimum voltage: 0 ... 10 V (1.5)
Limiter
540 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
replicated to another defined voltage range of the output sig-
nal/potential. In order to keep circuit wiring as straightforward as
possible, required earthing (0 V) is not led out as a terminal, but
rather wired internally.
The voltage range of the input and output signals is specified after
selecting the Operating mode option. The output signal is addition-
ally limited by the potentials applied to terminals A1 and A2 relative
to ground (0 V). If a positive potential is connected to A1 and a
negative potential to A2, the available output signal is no greater
than the smaller numeric value of the two (example: A1 = +15 V, A2
= -10 V => control range = 10 V). This can be further limited by
means of a parameter, in order to take losses from the control
electronics within the component into account.
Adjustable parameters
Operating mode: In [-10 V..10 V] > Out [0 V..10 V], In [-10 V..10 V]
> Out [-10 V..10 V],Enter manually (In [-10 V..10 V] > Out [0 V..10
V])
Efficiency: 0 ... 1 (0.9)
Min. Voltage (in): -400 ... 400 V (-10)
Max. Voltage (in): -400 ... 400 V (10)
Min. Voltage (out): -400 ... 400 V (-10)
Max. Voltage (out): -400 ... 400 V (10)
Minimum voltage: 0 ... 10 V (1.5)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 541
21.5.8 Controller (block diagram)
Summator
Adjustable parameters
y offset: -5 ... 5 V (0)
D element
Adjustable parameters
Derivation gain: 1 ... 1000 ms (2)
Time constant (PT1): 0.01 ... 100 ms (0.8)
542 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
P element
Adjustable parameters
Proportional gain: 0 ... 1000 (1)
Hysteresis element
Adjustable parameters
Hysteresis: 0 ... 10 V (0)
Minimum output voltage: -400 ... 400 V (-1)
Maximum output voltage: -400 ... 400 V (1)
I element
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 543
signal/potential at input 1 is summed up over time and results in
the output signal/potential at output 2. The speed at which the
input signal is integrated can be adjusted with the integral-action
coefficient. In order to keep circuit wiring as straightforward as
possible, required earthing (0 V) and supply voltage are not led out
as a terminals, but rather wired internally.
Adjustable parameters
Integral gain: 1 ... 1000 1/s (100)
PT1 element
Adjustable parameters
Time: 0.001 ... 1 s (0.01)
Proportional gain: 0 ... 10 (1)
PT2 element
Adjustable parameters
Time constant: 1e-5 ... 1 s (0.01)
Proportional gain: 0 ... 10 (1)
544 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Damping: 1e-5 ... 1000 s (1)
Differential amplifier
Limiter
The voltage range of the input and output signals is specified after
selecting the Operating mode option.
Adjustable parameters
Operating mode: In [-10 V..10 V] > Out [0 V..10 V], In [-10 V..10 V]
> Out [-10 V..10 V],Enter manually (In [-10 V..10 V] > Out [0 V..10
V])
Min. Voltage (in): -400 ... 400 V (-10)
Max. Voltage (in): -400 ... 400 V (10)
Min. Voltage (out): -400 ... 400 V (-10)
Max. Voltage (out): -400 ... 400 V (10)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 545
21.6 Digital Components
Digital input
Digital output
546 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Memory bits
Adjustable parameters
Initial state = Hi: ... (false)
Logic level HI
Logic level LO
Connection (digital)
Line (digital)
A digital line links two digital connections. Note that a digital con-
nection may be a simple digital connection or a T-junction.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 547
T-junction (digital)
AND
The output Q of the AND is only Hi when all inputs are Hi, that
is, if they are closed. If an input pin of this module is not connected,
its status is automatically Hi.
Edge-triggered AND
The output Q of the NAND is only Lo, when all inputs are Hi,
that is, if they are closed. If an input pin of this block is not con-
nected, its status is automatically Hi.
548 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
NAND With Edge Evaluation
OR
The output Q of the OR is only Hi, if at least one input is Hi, that
is, if it is closed. If an input pin of this block is not connected, its
status is automatically Lo.
The output Q of the NOR is only Hi when all inputs are Lo, that
is, if they are switched off. As soon as any input is switched on
(status Hi), the output of the NOR is set to Lo. If an input pin of
this block is not connected, its status is automatically Lo.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 549
21.6.3 Special Functions
Digital module
On delay
550 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Hi, the on delay time starts. If the status of input Trg is Hi at
least for the duration of the configured time, the output Q is set to
Hi on expiration of this time. The output follows the input with on
delay. The time is reset, when the status of the input changes again
to Lo before the time has expired. The output is reset to Lo,
when the status at the input is Lo.
Adjustable parameters
Delay time: 0 ... 100 s (3)
Off delay
The output is not reset until a configured time has expired. When
the input status turns to Hi, the output Q is switched instantane-
ously to Hi. If the status at input Trg changes from Hi to Lo,
the off delay starts. After expiration of the configured time, the
output is reset to Lo (off delay). When the input Trg is switched
on and off again, the off delay restarts. The input R (Reset) is used
to reset the delay time and the output before the configured time
has expired.
Adjustable parameters
Delay time: 0 ... 100 s (3)
On/Off delay
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 551
expiration of that time (the output follows the input off delayed). If
the status at the input returns to Hi before this time has expired,
the time is reset.
Adjustable parameters
On delay time: 0 ... 100 s (3)
Off delay time: 0 ... 100 s (6)
Retentive On delay
Adjustable parameters
Delay time: 0 ... 100 s (3)
Latching Relay
Pulse Relay
A short oneshot at the input is used to set and reset the output.
Output Q status is toggled at every Lo to Hi transition of the
status at input Trg, that is, the output is switched on or off. Use
input R to reset the pulse relay to initial state, that is, the output is
set to Lo.
552 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Wiping Relay - Pulse Output
Adjustable parameters
Delay time: 0 ... 100 s (3)
Adjustable parameters
Delay time: 0 ... 100 s (3)
Timer Switch
With the timer switch you can create timer switches referring to
days, weeks and years. Upon reach of the specified on-transition
time, the output Q of the timer switch is set to Hi and upon reach
of the specified off-transition time to Lo. If you have chosen the
option Repeat every, the on and off transition is repeated each
time according to the specified repetition time.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 553
Adjustable parameters
On time: 0 ... 1000 s (10)
Off time: 0.1 ... 1000 s (30)
Repeat every: 0.1 ... 1000 s (60)
Up/Down Counter
Adjustable parameters
Counter: 0 ... 9999 (5)
Adjustable parameters
Impulse time: 0.0005 ... 100 s (0.5)
554 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Asynchronous Pulse Generator
The pulse profile of the output can be changed via the configurable
pulse duration and pulse pause duration. It is possible to invert the
output with input INV. The input INV only negates the output, if the
block is enabled via EN.
Adjustable parameters
Impulse time: 0.01 ... 100 s (3)
Impulse pause time: 0.01 ... 100 s (1)
Adjustable parameters
On frequency: 0.01 ... 9999 Hz (6)
Off frequency: 0.01 ... 9999 Hz (2)
Time interval: 0.001 ... 100 s (5)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 555
21.7 GRAFCET Elements
21.7.1 GRAFCET
Step
Transition
You can give a transition a name, which is shown to the left of the
transition in brackets. Entering a transition condition is supported
by buttons for special symbols (AND, OR, NOT, falling edge, rising
edge, delay). Via Variable you can select an existing GRAFCET
variable from a list. Alternatively to the formula, you can show a
descriptive text. To do this, you have to select the option Display
description instead of formula. In the Connection ID/target in-
formation field, you can enter a step that links to the transitions
output without having to draw a connecting line. You can select an
existing step from a list.
Action
556 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
an Action on event, you can enter a condition that has to be
fulfilled before the action is executed. Entering a condition is sup-
ported by buttons for special symbols (AND, OR, NOT, falling edge,
rising edge, delay). Via Variable you can select an existing
GRAFCET variable from a list. Alternatively to the formula, you can
show a descriptive text. To do this, you have to select the option
Display description instead of formula. For an allocation (action
on activation, action on deactivation and action on event), you
can enter any term whose value is to be allocated to the action
variable. Entering a term is supported by buttons for special sym-
bols (AND, OR, NOT, falling edge, rising edge). Via Variable you
can select an existing GRAFCET variable from a list. Alternatively to
the formula, you can show a descriptive text. To do this, you have
to select the option Display description instead of formula. For a
compulsory command, you can enter the name of the partial
GRAFCET directly or select an existing partial GRAFCET from a list.
You can also enter the relevant steps directly or select them from a
list of existing steps. You have to separate the step names with
commas. You can select the special commands * and INIT using
the relevant buttons.
Synchronization
Partial GRAFCET
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 557
the frame and that the frame does not overlap with any foreign
elements or other frames.
GRAFCET-PLC-Component
GRAFCET-PLC-Component
GRAFCET-PLC-Component
GRAFCET-I/O
558 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
21.8 Miscellaneous
21.8.1 Miscellaneous
Connection (mechanical)
Valve solenoid
The valve solenoid switches the valve. By means of a label the valve
solenoid can be linked to a valve that is solenoid operated.
Adjustable parameters
Resistance: 1 ... 10000 Ohm (90)
Minimum voltage: 0.1 ... 300 V (20)
Adjustable parameters
Current (max): 0.01 ... 10 A (0.1)
Resistance: 1 ... 10000 Ohm (128)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 559
Minimum voltage: 0.1 ... 300 V (20)
Adjustable parameters
Current (max): 0.01 ... 30 A (0.1)
Jump current: 0 ... 25 % (0)
Resistance: 1 ... 10000 Ohm (100)
Minimum voltage: 0.1 ... 300 V (20)
Adjustable parameters
Current (max): 0.01 ... 30 A (0.1)
Jump current: 0 ... 25 % (0)
560 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Resistance: 1 ... 10000 Ohm (100)
Minimum voltage: 0.1 ... 300 V (20)
The valve solenoid switches the valve. By means of a label the valve
solenoid can be linked to a valve that is solenoid operated.
Adjustable parameters
Resistance: 1 ... 10000 Ohm (90)
Minimum voltage: 0.1 ... 300 V (20)
Distance rule
Status indicator
Cam switch
Text
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 561
The concept of text components in FluidSIM gives the user a way in
which to describe components in diagrams, assign identification
texts, or to provide commentary on the diagram. The text and the
appearance of text components can be customized to the users
liking.
State diagram
Functional diagram
Parts list
Rectangle
562 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Ellipse
Ellipses are graphic primitives, which can also be used within circuit
diagrams.
Bitmap
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 563
Learning, Teaching, and Visualizing Technologies
Chapter 22
22. Learning, T eachi ng, a nd Visual izi ng Technol ogies
The first three entries under the Didactics menu refer to selected
components and are context sensitive. More precisely:
564 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
22.1.1 Component Descriptions
You will find a photograph of the real-life part provided for most
components. In the case that a component cannot exist singularly
in a real system, FluidSIM displays a photo of the assembly group
that this component belongs to. Examples for such components
include the indicator light, relays, switches, and the electrical
power supply. Components, that do not exist in reality, simply have
no photo. Examples include the text component and the distance
rule.
Select the one-way flow control valve and click on the menu
item Component description under the Didactics menu.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 565
Figure 22/1: Technical page of the one-way flow control valve
566 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 22/2: Technical page of the throttle check valve
Under the heading Related topics, but also when appropriate in the
component description, cross references for related instruction
material and components are defined. By clicking on a cross refer-
ence, the related page will automatically be displayed.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 567
Select an air motor (4/2-way hand-lever valve in case of hy-
draulic version) and click on Component description under
the Didactics menu.
568 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 22/3: Page component-specific topics
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 569
Figure 22/4: Dialog box with component-specific topics
Please click the line with the relevant topic [35] Air
motor (hydraulics: [104] 4/2-way valve, two
pistons (1) ).
570 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 22/5: Function illustration of a air motor
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 571
Figure 22/6: Function illustration of a 4/2-way valve
572 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
An animation can be frozen with or by clicking on Pause in
the Execute menu. or Execute Stop stops an animation,
whereas or Execute Reset restarts an animation.
22.2.1 Tutorial
Below this menu option you can launch the tutorial Simulating
with FluidSIM, which contains a variety of interesting experiments
and an excursus. By means of these useful examples you will get to
know the possibilities of simulating with FluidSIM. Furthermore, for
the most important components the mathematic models used in
FluidSIM are also described.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 573
Figure 22/7: Tutorial (Pneumatics)
574 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 22/8: Tutorial (Hydraulics)
Below the menu option Component Library you will find descrip-
tions and photos of all FluidSIM -components.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 575
Figure 22/9: Component Library (Pneumatics)
576 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 22/10: Component Library (Hydraulics)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 577
Figure 22/11: Didactics Material (Pneumatics)
578 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 22/12: Didactics Material (Hydraulics)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 579
The following dialog box appears:
580 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 22/13: Dialog box for selecting and editing presentations
(Pneumatics)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 581
Figure 22/14: Dialog box for selecting and editing presentations
(Hydraulics)
New presentation... Clicking on New presentation... opens a second dialog box for
the creation of a new presentation.
Preview When the Preview setting is activated, the picture that pertains to
the selected presentation appears underneath the topics list.
582 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 22/15: Dialog box for editing presentations (Pneumatics)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 583
Figure 22/16: Dialog box for editing presentations (Hydraulics)
Available topics This field contains a list of all available topics dealing with Pneu-
matics basics, Hydraulics basics, Working principle, and
Exercise. Moreover, there exist two pictures that can be used to
announce a refreshment and a lunch break respectively. A double
click on a line in the Available Topics list inserts this line in the
Selected topics list above the highlighted bar. In this way a
presentation can be created or altered. Moreover, a user can inte-
grate his own circuit diagrams, DXF files, BMP- and WMF-picture
files, or even multimedia files such as sounds or video clips. To do
584 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
so, click on User file: A dialog box opens that allows for the
selection of the desired data source on the file system.
Selected topics This field contains a list of topics chosen for the current presenta-
tion.
Preview When the Preview setting is activated, the picture that pertains
to the selected topic appears underneath the respective list.
Within both topics lists the highlighted bar can be moved using the
arrow keys. Maybe it will be necessary to click and select the list
you want to work with. After creating a new presentation and clos-
ing the dialog box by clicking on &OK , FluidSIM asks you to
name the presentation file. Presentation files have the extension
.shw and are located in the subdirectory shw under the installa-
tion directory.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 585
Figure 22/17: Selection of an extended presentation
586 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 22/18: Actuators
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 587
Didactics Material Survey (Pneumatics)
Chapter 23
23. Didactics Material Survey (Pne umatics)
23.1 Basics
Circuit diagrams are drawn in such a way that signals, for instance
energy or potential values, are oriented downwards. The number-
ing of the components is derived from their respective function in
the diagram.
588 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
[3] Designating the elements, circuit diagram
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 589
23.2 Supply elements
The Symbols are from the DIN ISO 1219 Circuit symbols for fluidic
power components and systems. The symbols for the energy
supply system can be represented as individual components or as
combined elements.
590 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
[10] Compressed air filter
The compressed air passes through a baffle plate in the filter bowl.
The air is rotated, and the heavier dust particles and water droplets
are spun by centrifugal force against the inner wall of the filter bowl
and run down the wall of the housing. The air which has been
precleaned then passes through the filter element.
The lower the dew point the more the water will condense and
reduce the amount entrapped in the air. Using refrigeration meth-
ods, it is possible to achieve dew points of between 2{C} and
5{C}.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 591
[13] Air drying, adsorption
592 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
[16] Pressure regulator with vent hole
[17] Delivery
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 593
Discuss the advantages and disadvantages of piston compres-
sors.
[20] Distribution
594 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
atmospheric pressure fluctuates but is approximately 100 kPa (1
bar).
23.3 Actuators
The single acting cylinder and the double acting cylinder form the
basis for design variations. The use of cushioning to reduce loads
on the end caps and mountings during deceleration of the piston is
important for long-life and smooth operation.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 595
piston until the push-button is released. The next stage shows
retraction of the cylinder and the release of air via the exhaust port
of the 3/2-way valve.
596 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
The cylinder motion is controlled by air in both directions of motion.
The animation shows the advance and retraction sequences as
separate phases. The fully advanced position is related as long as
the push-button is actuated.
The first sequence shows the piston rod advancing. The second
stage the retraction. The speed of advance and retraction are fairly
constant under no load conditions.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 597
part of the stroke the speed is slowed to reduce impact on the
cylinder.
598 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
[33] Tandem double acting cylinder
The rotary actuator is compact with high torque ratings. The force is
transmitted to the drive shaft by a rotary vane. The range of angular
movement is adjustable with end stops. The angle can be adjusted
between 0 and 180. The adjustable stop system is separate to the
rotary vanes. This allows force to be absorbed by the stop blocks.
At the end positions, impacts are cushioned by elastic cushioning
rings.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 599
Discuss applications for the air motor.
600 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
[39] Methods of actuation (1)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 601
[42] 3/2-way valve, ball seat
The ball seat valve is compact with the possibility of fitting various
types of actuating heads. The limitation for directly actuated valves
is the force required to operate the stem. If the flow rate required is
very high, the valve ball will have a large working area. This re-
quires a large operating force. This limits the size of valve for this
design.
602 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
[44] 3/2-way valve, disc seat, normally open
A 3/2-way valve with free flow between ports 1 and 2 in the normal
condition, is referred to as normally open. Valves can be operated
manually, mechanically, electrically or pneumatically. The configu-
ration of the valve head is changed to meet the actuation method.
Upon operation of the actuating stem, the disc seat is sealed and
air supply port 1 is blocked. The air at port 2 is exhausted to at-
mosphere via port 3.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 603
The valve ports are labeled to ensure the correct connections are
made. The pilot valve is available in a range of sizes depending
upon the flow rate.
The valve is robust. Two stems directly operate the disc seats. The
load required to move the stems may be large for high flow rate
valves.
604 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Compare the construction with the 3/2-way valve.
The 4/2-way valve has four ports and two positions. A disc seat
4/2-way valve is similar in characteristic to the combination of two
3/2-way valves, one valve normally closed and the other normally
open. The plungers can be operated by an auxiliary mounted device
such as a roller lever or push-button. When the two plungers are
actuated simultaneously, 1 to 2 and 4 to 3 are closed by the first
movement. By pressing the valve plungers further against the
discs, opposing the reset spring force, the passages between 1 to 4
and from 2 to 3 are opened.
The 4/3-way valve has four ports and three positions. An example
of the 4/3-way valve is the plate slide valve with hand or foot
actuation. By turning two discs, channels are interconnected with
one another.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 605
[52] 5/2-way valve, longitudinal slide valve
The valve can be mounted onto a common sub-base for supply and
exhaust air. This compact arrangement also ensures adequate flow
is available to the valve.
The 5/2-way valve has five ports and two positions. The 5/2-way
valve is used for the control of cylinders primarily as a final control
element. In pneumatic valves, the gap between spool and housing
bore should not exceed 0.0020.004 mm. The valve is shown here
with pilot pressure applied at port 12. To avoid damage to seals,
the ports can be distributed around the circumference of the hous-
ing. The actuation travel is considerably larger than with seat
valves. The valve is shown here with pilot pressure at 14.
606 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
two manual override buttons to manually operate valve spool. The
animation shows the two switched positions. The air pilot signals
are applied from both directions. The manual override operations
are also shown. The manual overrides are used to manually actuate
the valve or initialize the valve position.
The 5/3-way valve has five ports and three positions. Signals ap-
plied at ports 14 or 12 operate the valve. If the valve is not actuated
it is closed in the mid-position. After actuation via a pilot signal at
port 14 air flows from 1 to 4. Port 2 exhausts via 3. After actuation
via a pilot signal at port 12 air flows from 1 to 2. Port 4 exhausts via
port 5.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 607
[57] Memory circuit, 5/2-way bistable valve
The valve 1V3 remains in the current position until the push-button
1S2 is operated. The cylinder then retracts. The cylinder remains
retracted until a new signal is generated at port 14 by the valve
1S1.
The flow control valves throttle the exhausting air in both directions
of piston motion. The cylinder remains retracted until a start signal
is generated at port 14 by the valve 1S1. The 5/2-way valve re-
mains in the current position with air supplied continuously to the
return side of the cylinder.
Discuss the situation when both 1S1 and 1S2 are operated
together.
608 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
[61] Direct control, unactuated
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 609
small capacity, the operation can be directly controlled by a push-
button control valve with spring return. On operating the push-
button, the air passes through the valve from port 1 to the port 4
and advances the piston rod. On release of the push-button, the
valve spring returns the control valve to its initial position and the
cylinder retracts. Air escapes from the cylinder via the exhaust port.
Since the cylinder is the only working element or actuator in the
circuit, it is designated 1A1. The final control element that advances
the cylinder is designated 1S1.
610 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
vances, the cylinder immediately returns to the initial position. The
control valve requires a sustained signal for it to remain operated.
The supply line can be short since the control valve can be
mounted close to the cylinder. The other advantage is that the
signal element (i.e. push-button 3/2 way valve) can be small,
as it only provides a signal to operate the control valve and is
not required to operate the cylinder directly.
The non-return or check valve will open due to the supply pressure
exceeding the resistance of the spring (if fitted) and the inertia of
the valve. The non-return valve is the basis for development of
many combined components. The shuttle valve, two pressure valve
and quick exhaust valve incorporate features of the non-return
valve.
Non return valves can stop the flow completely in one direction. In
the opposite direction the flow is free with a minimal pressure drop
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 611
due to the resistance of the valve. The one-way blocking action can
be effected by cones, balls, plates or diaphragms.
The two pressure valve has two inputs 1 and one output 2. The two
pressure valve is used mainly for interlocking controls, safety
controls, check functions or logic operations. The application of a
signal at a single input produces no pressure at output 2. If pres-
sure is applied at both inputs 1, the signal which is last applied
passes to the output 2. The two pressure circuit is equivalent to
two input signaling devices in series, i.e. one after the other.
612 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Discuss the logic function AND. Refer to the following topic
for additional conditions.
If the roller lever valve 1S2 is also operated, then the two pressure
valve will produce a 1-signal at port 2 which operates the control
valve, via pilot port 1V1, against the return spring and the cylinder
advances.
[75] Exercise: The logic AND function, the two pressure valve
Problem
[76] Exercise: The logic AND function, the two pressure valve
Solution
The two pressure valve is connected between the outlet lines of the
two 3/2 way valves. Operating the push-button, a 1-signal is gen-
erated at left input 1 of the two pressure valve. Once the part is
sensed as present, the 3/2 way roller valve generates a second 1-
signal, this time at the right input 1 of the two pressure valve. A
signal is passed through to port 2. This signal operates the control
valve pilot signal 14 against the spring return and the cylinder
advances. If either of the two signals created by the 3/2 way valves
is set to zero, the two pressure valve will release the 14 signal back
through the exhaust port of one of the 3/2 way valves. The return
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 613
spring in the control valve then switches the control valve to the
initial position. The control valve outlet port 2 is active and with
outlet port 4 exhausted to atmosphere the cylinder retracts. The
control valve can be a 4/2 or 5/2 way valve and can be sized to suit
the flow rate required for the cylinder speed.
[77] Exercise: The logic AND function, the two pressure valve
Note
614 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
1V1. This is an inadequate solution to the problem. A shuttle valve
is required.
The shuttle valve is connected to the junction between the two 3/2-
way push-button valves. Upon operation of one of the push-
buttons, a signal is generated at the X or Y port of the shuttle valve
and an output signal is emitted at port 2. The cylinder advances.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 615
valve. This signal passes through the shuttle valve and is emitted at
port 2. This operates the control valve via pilot port 14, and the
cylinder advances. A limit valve 1S2 senses that the cylinder has
fully extended. Pilot signal 2 from valve 1S2 actuates the 5/2 way
valve via port 12 and the cylinder retracts. The signal at port 12 is
only effective, if the opposing signal at port 14 is released. If both
of the signals produced via the push-button valves are set to zero,
then the shuttle valve will release the pilot signal 14 back through
the exhaust port of one of the 3/2 way valves. In other words, both
the push-button and the foot pedal must be inactive for retraction
to occur. The control valve can be a 4/2 way or 5/2 way valve and
can be sized to suit the flow rate required for the cylinder speed.
616 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
[88] Circuit: Quick exhaust valve
Initial position: In the initial state, the cylinder assumes the retract-
ed position. If both of the 3/2 way valves are actuated, pressure is
present at the output port 2 of the two pressure valve 1V4. This
reverses the 5/2 way control valve. The cylinder advances with air
being supplied via an unrestricted passage through the one-way
flow control valve 1V1. The actuator travels rapidly to its forward
end position since the pressure space on the piston rod side is
rapidly exhausted through the quick exhaust valve. If both 3/2 way
valves remain actuated, the cylinder remains in the forward end
position. If the push-button is released, the actuator is no longer
pressurized, since the control valve reverses via the return spring.
The actuator travels to its initial position under conditions of re-
stricted flow (valve 1V1) and therefore at a reduced speed.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 617
[91] Exercise: The quick exhaust valve Note
618 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
[95] Throttle valve
Compare the flow control with throttle valves and one-way flow
control valve topic 94.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 619
23.7 Pressure control valves
620 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
[100] Circuit: Pressure sequence valve
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 621
[103] Exercise: Pressure dependent control, embossing of plastic
Note
If the pressure does not reach the preset limit, then the cylin-
der will remain advanced. If the cylinder is obstructed during
extension to the forward position, the cylinder will not retract
due to the dependency upon operation of the limit vale 1S2.
The power circuit must be initialized by operating the 5/2 way
memory valve manually (via the manual overrides) with the air
off. The air can then be turned on.
The valve has a lock-able adjusting screw for setting time. The valve
is sized to meet the flow requirements.
Discuss the need for clean and stable air for accuracy. Discuss
the relationship between time delay and the reservoir size.
622 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
[106] Circuit: Time delay valve
The start conditions are the actuation of roller limit valve 1S3, a
delay of 5 seconds after the end of cycle and the operation of 1S1.
The two pressure valve 1V4 actuates the 5/2 way memory valve at
port 14. The cylinder advances at a preset speed via the flow con-
trol valve 1V2. The limit switch 1S3 is deactivated and therefore
even if the start button is still held, the signal at port 14 is exhaust-
ed by the removal of the limit switch signal, which resets the timer
1V6 until the cylinder has retracted again. The cylinder reaches the
limit valve 1S2 and produces a pilot signal for the time delay valve
1V5. The time delay valve opens port 2 if the preset time is reached.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 623
A pilot signal is produced 6 seconds after the limit valve 1S2 is
operated. The 5/2 way valve switches to the initial position and the
cylinder retracts and with speed controlled by the valve 1V1. The
roller limit valve 1S2 is deactivated and the pilot signal to the timer
1V5 is cut-off, removing the signal at port 12 of the 5/2 way valve.
624 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
[112] Exercise: Memory circuit and speed control of a cylinder
Note
The memory control valve 1V3 when first fitted could be in either of
two positions 14 or 12. It is not easy to predict the position of the
valve when fitted. If a manual override button is available the valve
should be manually set to the 12 position before turning on the air
to ensure that the cylinder remains retracted initially.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 625
[115] Signal overlap circuit I
The first overlap condition occurs at the start. The pilot signals at
the valve 1V2 from the valves 1S3 and 1S2 are opposed. The bista-
ble valve cannot move due to overlap.
The second overlap condition occurs in the third step. The valve
2V2 has signals generated by 2S1 and 2S2 opposing each other
and causing a signal overlap condition.
The first control valve 1V2 has an overlap problem in the first step.
The first of these signals must be out short and therefore valve 1S2
could be an idle return roller lever valve. The second overlap prob-
lem is with valve 2V2 in step 3, when the cylinder 2A1 is fully ad-
vanced. Valve 2S1 could be an idle return roller valve only active in
step 2 for a short duration.
626 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
[119] Idle return roller valve solution
The idle return roller limit switch can be used to remove the signal
overlap points, i.e. replace the roller lever limit switches identified,
with an idle return roller lever valve. Valves 1S2 and 2S1 generated
the signal overlap and therefore these valves should be idle return
roller valves.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 627
6 Sensors and relays Pressure switches 2:41
7 Sensors and relays Relays 3:34
8 Solenoid valves 2:48
9 Solenoid valves: Double-solenoid valves 1:47
10 Solenoid valves: Pilot control 3:58
11 Pilot control: Circuit-diagram conventions 4:14
12 Pilot control: Hard-wired controllers 4:58
13 Pilot control: Programmable Logic Control- 2:25
lers
23.11.1 Presentations
Presentation Title
All topics sorted by number
Basics
Supply elements
Actuators
Directional control valves
Shutoff valves
Flow control valves
Pressure control valves
Time delay valve
628 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Sequential circuit and signal overlap circuit
Educational films
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 629
Didactics Material Survey (Hydraulics)
Chapter 24
24. Didactics Material Survey (Hydra ulics)
24.1 Applications
[1] Lathe
630 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
[3] Mobile hydraulics: Excavator
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 631
direction of the hydraulic fluid. This drive section consists of cylin-
ders or hydraulic motors, depending on the application in question.
The light arrows show the signal flow, while the solid dark
arrows show the energy flow.
632 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
[9] Numbering in accordance with DIN ISO 1219-2
The DIN ISO Standard 1219-2 defines the code structure of the
components as a string consisting of the following four parts:
number of the plant, number of the circuit, component designation,
and component number. If the entire system consists of a single
plant only, the plant number may be dropped.
24.3 Symbols
The symbols shown are used in circuit diagrams for energy transfer
and hydraulic-fluid preparation.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 633
[12] Circuit symbols for energy transfer (2)
The direction of the arrows in the circuit symbols for the heater and
cooler correspond to the direction of heat flow.
The symbols for hydraulic motors are distinguished from the sym-
bols for hydraulic pumps by the fact that the arrows showing the
direction of flow are the other way round.
Single acting cylinders have one port, i.e. pressure fluid can be
applied only to the piston side. With these cylinders, the return
stroke is produced either by external force, shown in the symbol by
an opening bearing cap, or by a spring is shown within the symbol
in this latter case.
634 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
der by the two lines added to the end of the piston rod. The area
ratio is generally 2:1. In the case of cylinders with double- ended
piston rods, the symbol shows that the piston areas are of equal
size (synchronous cylinders).
This illustration shows the circuit symbols for 4/2- and 5/2-way
valves.
The illustration shows the circuit symbols for 4/3-way valves with
various mid-positions.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 635
ingly supplemented by a symbol indicating the actuation methods
shown, such as pushbuttons and pedals, a spring is always neces-
sary for resetting. Resetting can, however, also be achieved by
actuating the valve a second time, for example in the case of valves
with hand levers and detents.
This illustration shows the symbols for stem or push button, spring
and roller stem.
636 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
[24] Circuit symbols for non-return valves
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 637
Hydrostatic pressure has been ignored here. The term pressure
propagation is also used to mean the pulse velocity in liquids
(approx. 1000 m/s).
See topic 29
The fluid pressure p_1 exerts a force F_1 on the surface A_1 which
is transferred via the piston rod to the small piston. The force F_1
thus acts on the surface A_2 and produces the fluid pressure p2.
Since the piston area A_2 is smaller than the piston area A_1, the
pressure p_2 must be larger than the pressure p_1.
638 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
The pressure-transfer (pressure-intensification) effect is put to
practical use in pneumatic/hydraulic pressure intensifiers and
also in purely hydraulic systems when extremely high pres-
sures are required which a pump cannot deliver.
[35] Cavitation
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 639
bar), air dissolved in the oil is precipitated out. When the pressure
rises again due to a reduction in speed, the oil bursts into the gas
bubbles.
[36] Cavitation
The hydraulic power unit (power supply unit) provides the energy
required for the hydraulic installation. Its most important compo-
nents are the reservoir (tank) , drive (electric motor), hydraulic
pump, pressure relief valve (safety valve), filter and cooler. The
640 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
hydraulic power unit may also act as a carrier for other devices
(gauges, directional control valves).
The inner gear is driven by a motor. The teeth of the inner wheel
drive the outer gear wheel. The rotary motion creates a vacuum in
the gaps between the teeth, causing hydraulic fluid to be sucked in.
On the other side, the teeth engage once more and oil is displaced
from the tooth chambers.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 641
[42] Circuit diagram: Return flow filter
An oil filter situated in the return line to the tank has the advantage
that the filter is thus easy to maintain. A disadvantage, however, is
that contamination is removed from the hydraulic fluid only after it
has passed through the hydraulic components.
642 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
There are a number of different display methods. Either the
piston movement is directly visible or it is converted into an
electrical or visual indication by electrical contacts.
With this design of cooler, hydraulic fluid is fed through tubes over
which coolant (water) flows. The heat which is discharged can be
re-used.
Hydraulic fluid from the return line flows through a coiled pipe
which is cooled by a fan.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 643
Since this is an combination unit, a dot/dash line is placed
around the symbols representing the individual units.
644 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
[53] Poppet valves
The individual control edges of the pilot piston can have differ-
ent overlaps.
In the case of positive overlap, the left-hand piston does not open
the passage from P to A until the tank has been completely isolated
by the other piston. Pressure is immediately fed to the load device
(cylinder or hydraulic motor) with the result that this starts abrupt-
ly.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 645
[57] Control edges
The control edges of the pistons are often either sharp, chamfered
or notched. The profiling of the control edges means that the throt-
tling action of the flow when switching is gradual rather than ab-
rupt.
646 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
In this situation, for example, the piston rod is fully advanced;
the entire pump delivery is flowing at the preset system pres-
sure to the tank.
This illustration shows the correct circuit for the problem in topic
63. This circuit incorporates not only a brake valve on the piston-
rod side but also a non-return valve on the inlet side via which oil
can be taken in from a reservoir during the vacuum phase following
the closure of the directional control valve.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 647
The following animation shows the events which occur in the
two working lines.
The necessity of the brake valve can be demonstrated by topic 63.
Pressure shock arise, for example, when the pump delivers oil
in an almost unpressurized condition and the supply port of the
load device is abruptly closed by a directional control valve.
648 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
spring force. The passage from the supply port P to the tank port T
remains closed as long as no load acts on the pilot piston.
Pressure can be fed to the pilot piston via the pilot port X. As soon
as the pressure force at the pilot piston exceeds the preset spring
force, the pilot piston is displaced, allowing free flow.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 649
This valve is normally open. The outlet pressure (A) acts via a pilot
line on the left-hand surface of the pilot piston against an adjusta-
ble spring force.
The piston rod of the cylinder is now in its forward end position.
The pressure at outlet A thus continues to rise and the throttle
point closes completely.
650 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
[78] Circuit diagram: 2-way pressure regulator
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 651
increase causes the throttle gap to become narrower, resulting in a
pressure drop.
652 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
[86] 3-way pressure regulator (6)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 653
[90] 2/2-way valve as by-pass valve
In its initial position, the cylinder is advanced. If the 2/2- way valve
0V1 is actuated, the entire volumetric flow passes to the tank and
piston rod of the cylinder is reset by the external load m. If 0V1 is
not actuated, the system pressure set on the pressure limiter 0V2
builds up and the piston rod advances.
654 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
[94] Circuit diagram for pressure-less pump recirculation
The 3/2-way valve has working port A, a supply port P and a tank
port T. Volumetric flow can be routed from the supply port to the
working port or from the working port to the tank port. The third
port in each case is closed. In the normal position shown, P is
closed and flow released from A to T.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 655
[98] 3/2-way valve as final control element
The 3/2-way valve has a working port A, a supply port P and a tank
port T. The volumetric flow can be routed from the supply port to
the working port, or from the working port to the tank port. The
third port in each case is closed. In the normal position shown, P is
closed and flow is released from A to T.
656 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
[102] 3/2-way valve (slide principle) (2)
The 4/2-way valve has two working ports A and B, a supply port P
and a tank port T. The supply port is always connected to one of the
working ports, while the second working port is routed to the tank.
In the normal position, there is flow from P to B and from A to T.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 657
[106] 4/2-way valve, three pistons (1)
This 4/2-way valve has two working ports A and B, a supply port P
and a tank port T. The supply port is always connected to one of the
working ports, while the second working port is routed to the tank.
In the neutral position, there is flow from P to B and from A to T.
From the logic point of view, 4/3-way valves are 4/2- way valves
with an additional mid-position. There are various versions of this
mid-position (in the mid-position in the example shown, the supply
658 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
port P is directly connected to the tank T, see next illustration). In
the switching position shown, there is flow from P to B and from A
to T.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 659
[115] 4/3-way valve with pump bypass
The animations show the switching of the 4/3-way valve into the
three switching positions and the corresponding cylinder move-
ments. During the advance stroke, movement can be halted by
switching to the mid- position.
From the logic point of view, 4/3-way valves are 4/2- way valves
with an additional mid-position. There are various versions of this
mid-position (in the mid-position in the example shown, all ports
are closed in the mid- position, see next illustration). In the switch-
ing position shown, there is flow from P to B and from A to T.
The 4/3-way valve is in its mid-position; all ports apart from the
leakage-oil port are closed.
660 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
[119] 4/3-way valve with closed mid-position (4)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 661
[123] Way valve
Non-return valves block flow in one direction and allow free flow in
the other. In the direction of flow shown, the sealing element is
pressed against a seat by a spring and the hydraulic fluid.
662 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
[127] Circuit diagram: Pump protection
In the Graetz rectifier circuit (Graetz block), four non- return valves
are combined to form a function unit. The circuit diagram shows
how this operates in conjunction with a flow control valve; flow
passes through this valve from left to right during both the advance
and return strokes of the cylinder. The situation during the advance
stroke is shown.
The cylinder is on its return stroke. The rectifier circuit means that
flow once again passes through the flow control valve from left to
right.
During the return stroke shown here, flow control is carried out
on the outlet side.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 663
[131] Delockable non-return valve (1)
The released piston is pressurized via pilot port X. This lifts the
sealing element from its seat and releases flow from B to A.
664 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
[135] Delockable non-return valve
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 665
that the inlets A_1 and A_2 of the double non-return valve are
pressure-less and both cylinder supply lines are closed.
Its short narrowing means that the action of this gap flow control
valve is virtually independent of viscosity. The helix provides pre-
cise adjustability, since adjustment from fully open to fully closed
requires a 360 turn. The helix is, however, very costly to produce.
666 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
[142] Circuit diagram: Flow division using restrictor
Throttle and orifice valves control the volumetric flow rate in con-
junction with a pressure relief valve. The PRV opens when the
resistance of the flow control valve becomes greater than that of
the opening pressure set on the PRV. This produces a division of
flow.
The volumetric flow to the load device varies, i.e. the action of
flow control valves is load-dependent.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 667
[146] 2-way flow control valve (1)
When fluid flows through the valve, the pressure drop across the
adjustable restrictor is kept constant by the pressure compensator,
which varies the resistance at the upper throttle point in accord-
ance with the load at the inlet or outlet.
In the case of this flow control valve, the pressure difference is kept
constant by a adjustable restrictor, i.e. between p_1 and p_2. If the
pressure p_3 rises as the result of an external load, the overall
resistance of the valve is reduced by opening the regulating restric-
tor.
668 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
fitted in the by-pass to allow the flow control valve to be by-passed
on the return stroke.
In the case of a single acting cylinder, only the piston side is pres-
surized with hydraulic fluid. The cylinder can thus carry out work
only in one direction. The fluid which flows into the piston chamber
causes a pressure to build up the surface of the piston. The piston
travels into its forward end position. The return stroke is effected
by a spring, the dead weight of the piston rod or an external load.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 669
[152] Plunger cylinder
In the case of plunger cylinders, the piston and rod form a single
component. Due to the design of the cylinder, the return stroke can
only be effected by external forces. The cylinders can therefore
generally be installed only vertically.
Cylinder with end position cushioning are used to brake high stroke
speeds smoothly and prevent hard impacts at the end of the stroke.
Shortly before the end position is reached, the cross- section for
the outflow of fluid is reduced by the built-in cushioning pistons
and then finally closed. The hydraulic fluid is then forced to escape
through a flow control valve.
The piston is a short distance before its end position; the hydraulic
fluid on the piston-rod side must escape via the adjustable flow
control valve above the piston rod
670 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
This type of end position cushioning is used for stroke speed
between 6 m/min and 20 m/min. At higher speed, additional
cushioning or braking devices must be used.
The piston rod is on its return stroke; in this flow direction, the non-
return valve below the piston rod is opened, thus by-passing the
flow control valve. The piston rod retracts at maximum speed.
The illustration shows first the advance of the piston rod from a
mid-position to the forward end position, with cushioning at the
end of the advance movement. The non-return valve is open during
the return stroke.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 671
24.12 Gauges
672 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
24.13 Exercises
In order to draw the characteristic curve for the pump, the volu-
metric flow of hydraulic fluid delivered by the pump (Q) is plotted
against the operating pressure achieved (p). The manufacturers
characteristic curve exhibits a slight downward gradient, since the
new pump manifests increasing internal leakage losses as neces-
sary to provide internal lubrication. The newly-plotted curve shows
a clear deviation; the leakage oil losses have become greater at
higher operating pressures, the volumetric efficiency has become
worse. The main reason for this is pump wear. Regarding the circuit
diagram for the test assembly: The adjustable flow control valve
1V3 is adjusted in such a way that the pressure gauge 1Z1 shows
the desired system pressure. The pressure relief valve 1V2 is used
to limit the system pressure, while valve 1V1 acts as a safety valve
for the pump.
The measured values taken as the basis for this exercise do not
allow for the characteristic curve of the electric motor. The mo-
tor characteristic thus forms part of the calculated error.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 673
[164] Exercise: Bending machine (directly-controlled pressure
relief valve)
The volumetric flow which is discharged to the tank when the PRV
opens is entered on the horizontal axis. The characteristic curve
shows that the opening point of the PRV is 44 bar, although it is set
to 50 bar. This means that part of the pump delivery is diverted at
pressures greater than 44 bar. Pressures of more than 44 bar are
achieved during the bending process. Since, however, the flow is
divided from 44 bar onwards, the volumetric flow to the cylinder is
reduced from this point and the bending process slows down.
Measure to be taken: The PRTV can be set to 60 bar if the overall
installation has been designed for this higher pressure. Flow diver-
sion will then take place from a pressure of 54 bar onwards.
674 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
to another. A pressure of at least 30 bar is required for the transfer
of blocks by means of hydraulic cylinders. Every component
through which the hydraulic fluid flows represents a resistance and
causes a constant pressure loss. The question is, what pressure is
to be set at the pressure relief valve.
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 675
and a parts list prepared. A comparison is to be made of the behav-
ior of these two circuits during the advance and return strokes.
The requirements of the exercise are met by the first circuit dia-
gram only if the ladle represents a light load. If the ladle is very
heavy, the advance speed could rise to an unacceptably high level
during the advance stroke of the piston rod (ladle moving towards
furnace), and the ladle could as a result plunge too quickly into the
676 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
molten metal. This can be prevented by installing a back- pressure
valve in the B line between the valve and cylinder (tractive load).
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 677
stops, both the outlets A and B of the directional control valve
to the tank must be de-pressurized (A, B and T connected, P
closed).
678 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
[170] Exercise: Hydraulic crane (speed reduction)
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 679
must be added. The circuit diagram must be modified to ensure
that the flow control valve is not operative on the return stroke.
Finally, the relationship must be investigated between Q of the PRV
and the feed speed and between p_2 and the volumetric flow to the
load device.
680 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
switching positions should be described and the various piston
speeds and forces compared.
The drill feed and clamping device of a drilling machine are hydrau-
lically actuated. The hydraulic control system contains two cylin-
ders, a clamping cylinder 1A and a feed cylinder 2A. The clamping
pressure at cylinder 1A must be adjustable, since different
workpiece clamping forces are required. A pressure regulator is
used for this. The return stroke of the clamping cylinder must be at
maximum speed. The drilling feed must be adjustable for various
feed speeds, which must however remain constant under varying
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 681
load. It should also be noted that the drive spindle fitted to the
piston rod of the drilling cylinder acts as a tractive load. The return
stroke of the drilling cylinder should also be at maximum speed. A
circuit should be drafted with the above-mentioned characteristics.
682 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
24.14 Educational Films
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 683
24.15.1 Presentations
Presentation Title
All topics sorted by number
Applications
Components of a hydraulic system
Graphic and circuit symbols
Fundamental physical principles
Components of the power supply section
Valves in general
Pressure valves
Directional control valves
Non-return valves
Flow control valves
Hydraulic cylinders and motors
Measuring devices
Exercises
684 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Index
Index
3
3/2-way valve
ball seat _____________________________________ 601, 602
disc seat_____________________________________ 602, 603
pneumatically operated ________________________ 603, 604
roller operated____________________________________ 604
4
4/2-way valve
disc seat_________________________________________ 605
roller operated____________________________________ 605
4/3-way valve
turning disc principle_______________________________ 605
5
5/2-way valve
longitudinal slide principle __________________________ 606
suspended disc seat _______________________________ 607
5/3-way valve
pneumatically operated ____________________________ 607
A
air drying
absorption _______________________________________ 592
adsorption _______________________________________ 592
low temperature __________________________________ 591
air lubricator _____________________________________ 592, 593
air motor ____________________________________________ 600
air service unit _______________________________________ 590
C
circuit diagram
bistable valve ________________________________ 607, 608
direct control _____________________________________ 609
indirect control ___________________________________ 609
pressure sequence valve ___________________________ 621
quick exhaust valve ________________________________ 617
sequential control _________________________________ 625
shuttle valve _________________________________ 614, 615
signal overlap ________________________________ 626, 627
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 685
time delay valve___________________________________ 623
two pressure valve ____________________________ 612, 613
component
animation animation
component ______________________________________ 572
description didactics
component description ____________________________ 565
sectional view component
usage in circuit didactics
sectional view __________________________________ 567
compressed air filter filter ______________________________ 591
compressed air supply
axial flow compressor axial flow compressor ____________ 594
delivery _________________________________________ 593
distribution ______________________________________ 594
piston compressor piston compressor _________________ 594
cylinder
control cylinder
double acting ____________________________________ 597
single acting _____________________________________ 596
double acting _________________________________ 597, 598
mounting arrangements ____________________________ 598
seals____________________________________________ 598
single acting _____________________________________ 596
tandem double acting ______________________________ 599
D
Delay Switches ___________________________________ 477, 492
diagram symbol
designation of connections __________________________ 600
directional valve __________________________________ 600
flow control valve _________________________________ 618
linear actuator ____________________________________ 595
method of actuation _______________________________ 601
non-return valve diagram symbol
check valve ______________________________________ 611
numbering system _________________________________ 589
pressure control valve ______________________________ 620
rotary actuator____________________________________ 595
supply component_________________________________ 590
Dialog window
diagram properties ________________________________ 339
drawing areas ____________________________________ 342
Functional diagram ________________________________ 338
line options ______________________________________ 348
686 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
signal logic_______________________________________ 349
signaling elements ________________________________ 345
text options ______________________________________ 340
didactics
actuators ________________________________________ 595
applications ______________________________________ 630
basic pneumatics _________________________________ 588
cylinder didactics
motor __________________________________________ 669
directional control valves ___________________________ 600
educational film educational film
overview ____________________________________ 627, 683
exercises ________________________________________ 673
flow control valves ________________________________ 618
flow valves _______________________________________ 666
gauge ___________________________________________ 672
hydraulic plant____________________________________ 631
physical fundamentals _____________________________ 637
power unit _______________________________________ 640
presentation presentation
play ____________________________________________ 579
presentations
overview ________________________________________ 683
presentations presentation
overview ________________________________________ 628
pressure control valves _____________________________ 620
pressure valves ___________________________________ 646
sequential circuit didactics
signal overlap circuit ______________________________ 625
shutoff valves ________________________________ 611, 662
supply elements __________________________________ 590
symbols _________________________________________ 633
time delay valve___________________________________ 622
tutorial tutorial ___________________________________ 573
valves ___________________________________________ 644
way valves _______________________________________ 653
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 687
Digital Basic Functions _________________________________ 548
Digital Components ___________________________________ 546
Digital Special Functions _______________________________ 550
Digitale Constants ____________________________________ 546
DIN standard ________________________________________ 565
distance-step diagram _________________________________ 625
Druckschalter ________________________________________ 482
E
electrical components
american standard ________________________________ 491
ladder diagram style _______________________________ 491
Electrical Components _________________________________ 468
electronic components _________________________________ 497
exercise
bending machine __________________________________ 674
clamping device___________________________________ 678
drilling machine ___________________________________ 682
drying oven ______________________________________ 678
embossing press __________________________________ 676
feed control ______________________________________ 680
grinding machine__________________________________ 673
hydraulic crane ___________________________________ 679
ladle ____________________________________________ 677
planing machine __________________________________ 681
roller conveyor____________________________________ 675
F
function illustration
general sectional view______________________________ 575
G
GRAFCET Elements ____________________________________ 556
L
ladder diagram _______________________________________ 491
Limit Switches ___________________________________ 479, 493
M
measuring devices ____________________________________ 408
measuring instruments ________________________________ 463
menu
context sensitive context sensitive ____________________ 564
688 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Miscellaneous _______________________________________ 559
N
non return valve ______________________________________ 612
Numbering __________________________________________ 588
O
one-way flow control valve _________________________ 618, 619
P
Pneumatic Components ________________________________ 410
presentation
creation _________________________________________ 582
edit _____________________________________________ 582
pressure
absolute pressure
atmospheric _____________________________________ 595
pressure control valve _________________________________ 593
pressure switches ____________________________________ 393
Pressure Switches ____________________________________ 495
Proximity Switches ____________________________________ 484
Q
quick exhaust valve _______________________________ 616, 617
S
semi-rotary actuator___________________________________ 599
sequence valve _______________________________________ 620
Service Components __________________________________ 352
shuttle valve _________________________________________ 614
signal flow __________________________________________ 588
signal flow component _________________________________ 588
supply air throttling exhaust air throttling _________________ 619
supply elements ______________________________________ 410
switch
pressure operated _________________________________ 443
Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 689
T
Throttle valve ________________________________________ 619
time delay valve delay valve ________________________ 622, 623
two pressure valve ____________________________________ 612
V
valves
configurable _________________________________ 360, 417
directional _______________________________________ 364
directional valves _________________________________ 421
flow control ______________________________________ 393
flow control valves ________________________________ 437
groups __________________________________________ 451
pressure _________________________________________ 381
shutoff __________________________________________ 378
shutoff valves ____________________________________ 437
way valves ___________________________________ 360, 417
690 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM