Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

FluidSIMENUS PDF

Download as pdf or txt
Download as pdf or txt
You are on page 1of 690

FluidSIM 5

Users Guide

05/15
FluidSIM is a teaching tool for simulating pneumatics, hydraulics,
electrics/electronics and digital technique. It can be used in combi-
nation with the Festo Didactic GmbH & Co. KG training hardware,
but also independently. FluidSIM was developed as a joint venture
between the University of Paderborn, Festo Didactic GmbH & Co.
KG, Denkendorf, and Art Systems Software GmbH, Paderborn.
Contents

1. Welcome! 14

2. Installation 17

2.1 Technical requirements 17


2.2 Installation with program activation 18
2.2.1 Important information about online activation 18
2.3 Installation with a license connector 19
2.4 Installing the full version from DVD-ROM 19

3. First steps 21

3.1 Create a new circuit drawing 21


3.2 Organize symbols, libraries and circuit diagrams 25
3.3 Insert symbol from menu 26
3.4 Symbol libraries 28
3.4.1 Create user library 29
3.5 Circuit files 30

4. Library and project window 31

4.1 Change window position 31


4.2 Automatic show and hide 31

5. Edit circuit 33

5.1 Insert and arrange symbols 33


5.2 Connect connectors / ports 33
5.3 Automatically connect connectors 35
5.4 Insert T distributor 37
5.5 Move lines 40
5.6 Direct connection via straight connection line 42
5.7 Define the characteristics of lines 43
5.8 Delete line 45

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 3


5.9 Set the properties of the connectors 45
5.10 Configure a way valve 47
5.11 Configure cylinders 49
5.12 Group symbols 51
5.13 Create macro objects 51
5.14 Delete symbol groups and macro objects 52
5.15 Align symbols 52
5.16 Mirror symbols 52
5.17 Rotate symbols 53
5.18 Scale symbols 54

6. Drawing frame 56

6.1 Editable labels 56


6.2 Use a drawing frame 57
6.3 Page dividers 61

7. Additional tools for creating drawings 65

7.1 Drawing tools 65


7.1.1 Grid 65
7.1.2 Alignment lines 65
7.1.3 Object snap 66
7.1.4 Rulers 67
7.2 Drawing levels 67
7.3 Cross-references 69
7.3.1 Create cross-references from symbols 71
7.3.2 Cross-reference representation 71
7.3.3 Manage cross-references 72
7.4 Drawing functions and graphical elements 74
7.4.1 Interruption/Potential 75
7.4.2 Conduction line 78
7.4.3 Line 80
7.4.4 Polyline (set of connected lines) 82
7.4.5 Rectangle 83
7.4.6 Circle 85
7.4.7 Ellipse 86

4 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM


7.4.8 Text 88
7.4.9 Image 88
7.5 Check drawing 90

8. Simulating with FluidSIM 91

8.1 Simulation of existing circuits 91


8.2 The different simulation modes 93
8.2.1 Reset and restart of the simulation 94
8.2.2 Single step mode 94
8.2.3 Simulation to a state change 94
8.3 Simulating circuits you create yourself 95
8.3.1 Example with a pneumatic circuit 95
8.3.2 Example with a hydraulic circuit 103
8.3.3 Example with an electronic circuit 111

9. Advanced concepts in simulating and creating circuits 120

9.1 Adjusting the component parameters 120


9.2 Special settings for cylinders 124
9.2.1 Cylinder friction and cylinder mass 124
9.2.2 External load and friction 125
9.2.3 Force profile 128
9.2.4 Actuating labels 130
9.3 Special settings for directional control valves 131
9.3.1 Hydraulic resistance 131
9.4 Additional simulation functions 132
9.4.1 Simultaneous actuation of several components 133
9.4.2 Simulation of individual pages and entire projects 133
9.5 Displaying quantity values 134
9.5.1 Display of direction of quantity values in FluidSIM 136
9.6 Displaying state diagrams 137
9.7 Coupling hydraulics, pneumatics, electrics and mechanics
139
9.7.1 Display styles for labels 147
9.8 Operating switches 148
9.8.1 Switches at cylinders 149

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 5


9.8.2 Relays 151
9.8.3 Coupling mechanical switches 152
9.8.4 Automatic switch altering 152
9.9 Adjusting component parameters during the simulation 153
9.10 Settings for simulation 155
9.11 Use of the EasyPort-hardware 155
9.12 OPC and DDE communication with other applications 157
9.13 Open-loop and closed-loop control by using continuous
valves 159
9.13.1 Open-loop control in pneumatics 161
9.13.2 Open-loop control in hydraulics 163
9.13.3 Closed-loop control in pneumatics 166
9.13.4 Closed-loop control in hydraulics 172
9.14 Use of the oscilloscope in electronics 178
9.15 Simulation of rotating machines 180

10. GRAFCET 183

10.1 The various GRAFCET modes 183


10.1.1 Drawing only (GrafEdit) 184
10.1.2 Observation (GrafView) 184
10.1.3 Control (GrafControl) 184
10.2 Setting the GRAFCET mode 185
10.3 GRAFCET elements 185
10.3.1 Steps 186
10.3.2 Actions 188
10.3.3 Transitions 190
10.3.4 Stored effective actions (allocations) 193
10.3.5 GRAFCET-PLC component 194
10.4 Access to variables of circuit components 198
10.5 Monitoring with GRAFCET actions 201
10.6 Quick reference for the FluidSIM-relevant GRAFCET concepts
207
10.6.1 Initialization 207
10.6.2 Sequence rules 208
10.6.3 Sequence selection 208
10.6.4 Synchronization 208

6 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM


10.6.5 Transient sequence / unstable step / virtual triggering 209
10.6.6 Determining the values of GRAFCET variables 209
10.6.7 Checking the entries 209
10.6.8 Admissible characters for steps and variables 210
10.6.9 Variable names 210
10.6.10 Functions and formula entry 211
10.6.11 Delays / time limits 212
10.6.12 Boolean value of an assertion 213
10.6.13 Target information 214
10.6.14 Partial GRAFCETs 214
10.6.15 Macro-steps 214
10.6.16 Compulsory commands 215
10.6.17 Enclosing step 215
10.6.18 Action when a transition is triggered 216

11. Dimension 217

11.1 Draw dimension 217


11.2 Settings for the dimension 218

12. Component attributes 220

12.1 Component attributes in the Properties dialog window 221


12.2 User Defined Properties 223
12.3 Drawing Properties 224
12.4 Main and secondary components 225
12.5 Linking main and secondary components 225
12.6 Link solenoid valves and solenoid coils 227
12.7 Attributes of the text components 231
12.8 Link text components with attributes 234
12.9 Text components with specified links 236
12.10 Change the properties of multiple objects simultaneously
237
12.10.1 Drawing Properties 237
12.10.2 Main Component 239

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 7


13. Parts list management and analyses 241

13.1 Display parts list 242


13.2 Find components from the parts on the circuit diagram 243
13.3 Set parts list properties 245
13.4 Export parts list 248
13.5 Insert tube list 249

14. Manage projects 252

14.1 Create new project 252


14.2 Project nodes 253
14.2.1 Project archiving 253
14.3 Circuit and parts list nodes 254

15. Circuit and project properties 256

15.1 Attributes 257


15.1.1 Predefined placeholders 259
15.2 Page Dividers 260
15.3 Basic Unit Length 260
15.4 Encryption 261
15.5 Cross Reference Representation 263

16. Special functions for electric circuits 264

16.1 Potentials and conduction lines 264


16.2 Cables and wiring 266
16.2.1 Manage cables 272
16.2.2 Insert cable map 273
16.2.3 Insert cable list 275
16.2.4 Insert wiring list 278
16.3 Terminals and terminal strips 281
16.3.1 Set terminals 281
16.3.2 Set multiple terminals 283
16.3.3 Create terminal strips 285
16.3.4 Manage terminal strips 286

8 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM


16.4 Terminal diagram 288
16.4.1 Set links 290
16.5 Contact images 294

17. Circuit input and output 297

17.1 Print circuit diagram and parts list 297


17.2 Import DXF file 299
17.3 Export circuit 299

18. Options 301

18.1 General 301


18.2 Save 302
18.3 Folder Locations 303
18.4 Language 304
18.5 Dimension 304
18.6 Cross Reference Representation 306
18.7 Connector Links 307
18.8 Warnings 308
18.9 Automatic Updates 309
18.10 Simulation 310
18.11 GRAFCET 312
18.12 DDE Connection 313
18.13 Environment parameters 313
18.14 Fluid properties 314
18.15 Sound 314
18.16 Text Sizes 316

19. Menu overview 317

19.1 File 317


19.2 Edit 320
19.3 Insert 322
19.4 Draw 324
19.5 Page 325
19.6 Execute 326

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 9


19.7 Didactics 327
19.8 Project 328
19.9 View 329
19.10 Library 333
19.11 Tools 334
19.12 Window 335
19.13 Help 336

20. Functional diagram 337

20.1 Edit Mode 338


20.1.1 Set diagram properties 338
20.1.2 Table textboxes 339
20.1.3 Adjust the presentation of the diagrams 342
20.2 Draw diagram curve 343
20.3 Insert signal elements 344
20.4 Insert text boxes 345
20.5 Draw signal lines and insert signal connections 347
20.5.1 Free-draw signal lines 347
20.5.2 Drawing signal lines from signals 349
20.5.3 Draw signal lines from diagram support points 349
20.6 Insert additional signal lines 350
20.7 Insert row 350
20.8 Delete row 350
20.9 Additional editing functions 351
20.9.1 Zoom 351
20.9.2 Undo editing steps 351

21. The Component Library 352

21.1 Hydraulic Components 352


21.1.1 Service Components 352
21.1.2 Configurable Way Valves 360
21.1.3 Mechanically Actuated Directional Valves 364
21.1.4 Solenoid-actuated Directional Valves 372
21.1.5 Shutoff Valves 378
21.1.6 Pressure Control Valves 381

10 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM


21.1.7 Pressure Switches 393
21.1.8 Flow Control Valves 393
21.1.9 Continuous valves 397
21.1.10 Actuators 402
21.1.11 Measuring Devices 408
21.2 Pneumatic Components 410
21.2.1 Supply Elements 410
21.2.2 Configurable Way Valves 417
21.2.3 Mechanically Operated Directional Valves 421
21.2.4 Solenoid Operated Directional Valves 429
21.2.5 Pneumatically Operated Directional Valves 433
21.2.6 Shutoff Valves and Flow Control Valves 437
21.2.7 Pressure Operated Switches 443
21.2.8 Pressure Operated Switches 447
21.2.9 Vacuum Technique 448
21.2.10 Valve Groups 451
21.2.11 Continuous valves 454
21.2.12 Actuators 454
21.2.13 Measuring Instruments 463
21.3 Electrical Components 468
21.3.1 Power Supply 468
21.3.2 Actuators / Signal Devices 471
21.3.3 Measuring Instruments / Sensors 473
21.3.4 General Switches 476
21.3.5 Delay Switches 477
21.3.6 Limit Switches 479
21.3.7 Manually Operated Switches 481
21.3.8 Pressure Switches 482
21.3.9 Proximity Switches 484
21.3.10 Relay 485
21.3.11 Controller 487
21.3.12 EasyPort/OPC/DDE Components 489
21.4 Electrical Components (American Standard) 491
21.4.1 Power Supply 491
21.4.2 General Switches 491
21.4.3 Delay Switches 492
21.4.4 Limit Switches 493

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 11


21.4.5 Manually Operated Switches 494
21.4.6 Pressure Switches 495
21.4.7 Relays 496
21.5 Electronic components 497
21.5.1 Power supply 497
21.5.2 Passive components 500
21.5.3 Semiconductor 504
21.5.4 Measuring instruments / Sensors 511
21.5.5 Switches 513
21.5.6 Machines 516
21.5.7 Controller 533
21.5.8 Controller (block diagram) 542
21.6 Digital Components 546
21.6.1 Constants and Terminals 546
21.6.2 Basic Functions 548
21.6.3 Special Functions 550
21.7 GRAFCET Elements 556
21.7.1 GRAFCET 556
21.8 Miscellaneous 559
21.8.1 Miscellaneous 559

22. Learning, Teaching, and Visualizing Technologies 564

22.1 Information about Single Components 564


22.1.1 Component Descriptions 565
22.1.2 Component Illustrations 567
22.2 Selecting Didactics Material from a List 573
22.2.1 Tutorial 573
22.2.2 Component Library 575
22.2.3 Didactics Material 577
22.3 Presentations: Combining Instructional Material 579
22.4 Extended Presentations in the Microsoft PowerPoint Format
585

23. Didactics Material Survey (Pneumatics) 588

23.1 Basics 588

12 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM


23.2 Supply elements 590
23.3 Actuators 595
23.4 Directional control valves 600
23.5 Shutoff valves 611
23.6 Flow control valves 618
23.7 Pressure control valves 620
23.8 Time delay valve 622
23.9 Sequential circuit and signal overlap circuit 625
23.10 Educational Films 627
23.10.1 Educational Films 627
23.11 Standard Presentations 628
23.11.1 Presentations 628

24. Didactics Material Survey (Hydraulics) 630

24.1 Applications 630


24.2 Components of a Hydraulic Plant 631
24.3 Symbols 633
24.4 Some Physical Fundamentals 637
24.5 Components of a Power Unit 640
24.6 Fundamentals of Valves 644
24.7 Pressure Valves 646
24.8 Way Valves 653
24.9 Shutoff Valves 662
24.10 Flow Valves 666
24.11 Hydraulic Cylinders and Motors 669
24.12 Gauges 672
24.13 Exercises 673
24.14 Educational Films 683
24.14.1 Educational Films 683
24.15 Standard Presentations 683
24.15.1 Presentations 684

Index 685

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 13


Welcome!

Chapter 1
1. Welcome!

Welcome to FluidSIM!

Thank you for purchasing the FluidSIM training software. This


users guide functions both as an introduction to FluidSIM and as a
reference manual outlining the possibilities, concepts and opera-
tion of the software package. This guide is not designed for the
teaching of training content in fluid engineering or electronics; if
you require materials for that purpose, there are textbooks availa-
ble from Festo Didactic GmbH & Co. KG.

FluidSIM permits the creation and simulation of circuits in the


following fields:

Electro-pneumatics/vacuum technology

Electro-hydraulics/mobile hydraulics

Electrical engineering/electronics

There are specialized versions of the program for each of these


technologies, referred to in the following as FluidSIM-P, FluidSIM-H
and FluidSIM-E respectively.

All three versions also contain components for drawing creation


and simulation of:

Digital technology

GRAFCET

Some of the functions and components described in this manual


may not be available, depending on which program versions you
purchased. In places where the programming differences between
the technologies are only minor, general examples are given, and
the specific differences are mentioned. When specialized functions
are explained, such as closed-loop control in pneumatics and in
hydraulics, a separate chapter is devoted to each function.

For the first time you can link all technologies in FluidSIM in a single
circuit or project. This means that if you have purchased all three
technology versions, you can utilize pneumatic, hydraulics, control
technology, electronics, digital technology etc. in any way you want

14 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM


in a single technical system. FluidSIM ensures that you can only
join connections which are also physically possible.

A major feature of FluidSIM is its close linkage between CAD func-


tionality and simulation. On the one hand, FluidSIM allows DIN-
compliant drawing of fluidic and electronic circuit diagrams; on the
other hand, it is capable of using physical component descriptions
to carry out a realistic, dynamic simulation of the drawn circuit. This
practically eliminates the separation between drawing creation and
simulation.

When developing FluidSIM, special emphasis was placed on mak-


ing operation intuitive and easy to learn. This approach makes it
possible for you to learn to design and simulate fluidic and elec-
tronic circuit diagrams in a very short time. To provide access to
professional functions not present in this simple operating inter-
face, FluidSIM also has an Expert Mode which can be switched on
as needed.

FluidSIM-P was created by the Knowledge-based Systems


workgroup at the University of Paderborn. FluidSIM-H is the result
of cooperative research between the Instrumentation and Control
department at Gerhard Mercator University in Duisburg, and
Knowledge-based Systems at the University of Paderborn. On hand
for mechanical engineering matters was Dr Ralf Lemmen. FluidSIM-
E was developed as an entirely new module by Art Systems Soft-
ware GmbH.

Planning and development of FluidSIM: Dr Daniel Curatolo, Dr


Marcus Hoffmann and Dr Benno Stein.

Users of this software are encouraged to contribute tips, criticism,


and suggestions for improvement of FluidSIM via email.

info@fluidsim.de

did@de.festo.com

You can also find the newest version on the following websites:

www.fluidsim.de

www.festo-didactic.de

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 15


16 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Installation

Chapter 2
2. Installation

With your purchase of the full version of FluidSIM, you received one
or more DVD-ROMs and possibly a license connector. The installa-
tion procedure is described in the following sections.

The full version of FluidSIM is available in two versions: a version


that supports automatic Online activation, and the version with a
license connector for insertion in a USB port.

2.1 Technical requirements

You need a computer running Windows XP (SP3), Windows Vista,


Windows 7 or Windows 8.

If you intend to simulate complex circuits, a computer with dual


processor is recommended. Stand-alone tablet PCs without a
physically connected mouse are not ideal because creating draw-
ings is impractical using only swipe and gesture control.

During simulation, most of the adjustable components can be


controlled using a game controller as an alternative to the mouse.
You can use any game controller which Windows recognizes and
which appears in the Control Panel. You may need the matching
device drivers for Windows.

Additional drivers may be necessary in order to link FluidSIM to


external hardware. Compatible drivers for Festos EasyPort can be
found in the Support subfolder on the DVD. Communication with
other applications via OPC requires special auxiliary modules,
which are likewise located in the Support folder. For more details
about OPC, see the section OPC and DDE communication with other
applications.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 17


2.2 Installation with program activation

We recommend activating the program via a PC connected to the


internet. During installation, you will be prompted to activate
FluidSIM. There are three ways of doing so:

Online activation
This variant allows fully automatic activation if the installation
PC has direct access to the internet.

Indirect activation
In this case the PC on which FluidSIM is to be installed does not
need to have direct internet access. Instead, the subsequent
dialog window gives you an internet address and an individual-
ly generated license key. You can then generate a matching ac-
tivation code by accessing the displayed internet address from
any computer. You then enter that activation code in the field
provided in the activation dialog box on the installation PC.

Call Festo to receive your activation code


If you do not have an internet connection or if the internet con-
nection fails, you can call our service staff on weekdays during
standard office hours and they will provide you with your acti-
vation code.

2.2.1 Important information about online activation

During program activation, the individual features of your PCs


hardware are linked to the product ID and used to generate an
activation code which is valid only for that PC. If at some later time
you intend to modify your PC substantially or want to use a new PC,
you can transfer the license. To do so, you first have to deactivate
the license on the original PC, by uninstalling the program. You can
find the deinstallation procedure in the Control Panel in Add or
Remove Programs or Programs.

18 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM


If the PC on which you installed FluidSIM is no longer functional or
deactivation fails for some other reason, as an exception you can
transfer the license without prior deactivation.

Please note that this type of license transfer (without prior deacti-
vation) is only possible a few times. Moreover, when you transfer a
license to a modified or new PC, activation is no longer possible on
the original PC. Once the license is transferred, you cannot activate
FluidSIM on the original PC without a prior deactivation.

2.3 Installation with a license connector

Depending on whether you purchased a multiple or single user


license, this special connector is either connected directly to the
local users computer or is on a license server at a central location
in your network.

In the case of network licensing, the connector defines how many


instances of FluidSIM can run simultaneously on the network. If you
try to start more instances of FluidSIM than are permitted, you will
see a corresponding error message. If the license server is down or
the license connector is no longer present, you will be able to save
any circuits you are working on before FluidSIM terminates. As
soon as the license server becomes available again, you can re-
sume your work.

Detailed information on network installation of FluidSIM can be


found in the installation guide included as a booklet in the product
packaging, and also in electronic form as a PDF file in the Doc
folder on the installation DVD.

2.4 Installing the full version from DVD-ROM

If you are using the software with a license connector, do not plug
it in until you are prompted to do so by the installation program.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 19


Switch on your computer and log on with administrator rights.

Insert the DVD-ROM.

Usually the installation program starts automatically. If it doesnt,


please start it manually.

After a few seconds the start screen of the installation program


appears. Here you can select whether you have received the ver-
sion for online activation or a license connector with the FluidSIM
package.

Note that there are two versions of the license connector: The
newer one is silver in color and has the product label CodeMeter.
If you have purchased FluidSIM as an update of an earlier version,
you can also continue to use your existing green WibuKey con-
nector if it has been reprogrammed accordingly.

For online activation, you do not need a license connector; instead


you require your individual product ID which is printed on the back
of the DVD case.

Follow the instructions of the installation program. If you are


not sure how to answer any of the questions, simply click
Next .

20 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM


First steps

Chapter 3
3. First steps

3.1 Create a new circuit drawing

When you start FluidSIM, the system checks whether you have
installed more than one technology (pneumatics, hydraulics, elec-
tronics). If you have, the selection window appears listing the
available technologies. Here you specify which components and
program functions you wish to use in this program session. This
decision is especially important for network users because a li-
cense will be occupied for each technology until you exit FluidSIM.
You can restart FluidSIM at any time and select a different combina-
tion.

Figure 3/1: Select Technologies dialog window

Available technologies The available technologies and the currently free licenses are
displayed here.

FluidSIM remembers the last selection and suggests it when the


program is next started. If you frequently use different combina-
tions, you can create links which will allow you to start FluidSIM
directly with the corresponding selection.

Next, the key concepts and terms are described which you will
encounter when using FluidSIM.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 21


Start FluidSIM with the selection you require.

In the menu File , select New / File... .

An empty circuit window opens in which you can insert symbols


and connect them with lines. First you should set the drawing size.

In the Page menu, select Paper Size... .

22 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM


Figure 3/2: Page dialog window, Drawing Size tab: setting the
drawing size

If you use a drawing frame, then FluidSIM can automatically adjust


the paper size. If you wish to define the drawing size manually, then
deactivate the Adopt from drawing frame option and select the
dimensions and orientation you require for the drawing. If the
drawings dimensions are larger than your printers printing area
then you can distribute your drawing across several pages (tile).

To retain a better overview you can create attributes for every


circuit drawing.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 23


Click the Attributes tab.

Figure 3/3: Page dialog window, Attributes tab: creating attrib-


utes

The attribute table allows you to save any desired data in the form
of attribute value pairs. The associated placeholders (attributes
with the same name) in the drawing frame are replaced by the
values entered.

24 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM


You can also access this dialog window directly by using the Page
menu and the Properties... menu item.

3.2 Organize symbols, libraries and circuit diagrams

In order to support the organization of the different document


types in FluidSIM all of the circuit files are assigned to one of three
groups.

Symbols Symbols are formal, abstract models providing a graphical repre-


sentation of the function of a component or component group. This
can consist of simple circuit symbols or entire circuits. Symbols can
be inserted into their own circuits and linked between the connect-
ing points. The insert can be performed either via the Insert menu
or via drag and drop from a library window. Symbols can be com-
piled into library files with the lib file suffix.

Libraries Libraries are hierarchically organized collections of symbols. In


addition to the standard library, which users cannot modify, users
can compile any desired number of their own libraries. You can find
functions for organizing the libraries on the Library menu as well
as on the context menu of the currently active library. To switch
libraries use the tab in the upper margin of the library window.
Library files have the lib file suffix.

Circuits The default location for circuits is in the FluidSIM folder con-
tained in the My Documents folder defined by the operating sys-
tem. These have the circ file suffix.

Note: It is worthwhile to create a new sub-folder in the FluidSIM


directory for every customer or every project.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 25


3.3 Insert symbol from menu

To find a specific symbol you can either enter characteristic key


words in the Find Symbol dialog windows or navigate through the
hierarchical structure.

Where necessary open a new window and select the Find


Symbol Description... entry on the Insert menu.

The Find Symbol dialog window then opens. You can enter your
search terms in the Search input line. Separate the individual
search terms using commas or spaces. Neither the order of the
search terms nor upper or lower case letters have any influence on
the search results.

26 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM


Figure 3/4: Find Symbol dialog window

You can see the symbols found in the two results lists. The library
hierarchy is displayed on the left-hand side although only those
branches appear which contain matching symbols. An alphabetical
list of the search hits is displayed on the right-hand side. The sym-
bol of the highlighted entry is shown in the preview. Once you have
found the symbol that you were looking for, you can select it using
the &OK button or by double-clicking on the appropriate row in
the results list. The symbol then hangs on the mouse pointer and
is placed by left-clicking on the drawing area.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 27


With the Fuzzy Search option you can activate a tolerance in order
to achieve results despite minor typing errors or spelling variants.

3.4 Symbol libraries

FluidSIM is capable of managing multiple libraries, each of which is


displayed in a tab in the library window. Libraries which cannot be
modified in FluidSIM are labeled with a lock symbol in the tab.
This applies to standard library as well as to symbol folders which
FluidSIM does not manage itself or for which the registered user
does on possess write authorization.

Every library is displayed hierarchically. Every hierarchy level can by


shown or hidden by clicking on the group name. Right-clicking in a
library opens a context menu offering the following menu items for
editing the library:

View Defines the size of the symbols displayed. Small , Normal and
Large are available.

Expand All Opens all of the hierarchy levels.

Collapse All Closes all of the hierarchy levels.

There are three types of library:

The standard library This library is delivered with FluidSIM and cannot be modified.

Symbol folders Circuit and symbol files saved on the disk can be used as libraries
in FluidSIM. The files from the selected folder are added as a library
via the Library menu and the Add Existing Symbol Folder...
menu item. The library hierarchy corresponds exactly to the folder
hierarchy. These libraries cannot be modified in FluidSIM. The files
must be modified directly.

User libraries You can create and subsequently edit new libraries via the Library
menu and the Add New Library... menu item (see section Create

28 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM


user library). Using drag and drop you can move the symbols and
groups within the library as desired.

3.4.1 Create user library

In order to be able to access frequently used symbols (or circuits)


more quickly multiple symbols can be compiled into libraries.
Libraries are saved as files with the lib file suffix. You can create
new libraries using the Library and the Add New Library... menu
item. Right-clicking in the new library opens a context menu with
which you can modify the library.

The following options are available:

Copy Copies the selected symbols to the clipboard

Paste Inserts the symbols into the library from the clipboard. These
symbols can also be partial circuits.

Delete Removes the selected symbols from the library.

Rename... Edits the text which libraries display below the symbol.

Add Existing Symbols... Opens a dialog window for selecting symbol files to be copied into
the library as new symbols.

Copy to Other Library Copies the selected symbols into another library. The available
libraries are listed in a submenu. Only the currently open libraries
are displayed here (appearing as tabs in the library window) which
are not write-protects (recognizable as no lock symbol is dis-
played).

New Sub-Folder... Creates a new hierarchy level below the active group. The active
group is the one belonging to the area below the mouse point and
can be recognized by the dark blue coloring.

Remove Sub-Folder Removes the hierarchy level which the mouse pointer is located in.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 29


Rename Sub-Folder... Enables you to rename the hierarchy level which the mouse pointer
is located in.

3.5 Circuit files

FluidSIM circuit files have the circ file suffix and are saved as
compressed XML files. An option in the Save tab under the Op-
tions... menu item from the Tools menu allows you to deactivate
this compression so that the circuit files can be viewed as plain
text. This can be useful for version management software, for
example.

However, please note that editing a circ file outside FluidSIM can
cause the file to become unreadable or corrupted upon re-import.

30 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM


Library and project window

Chapter 4
4. Library and project window

4.1 Change window position

The library window is anchored on the left-hand side by default and


the project window (when a project is open) is on the right-hand
side.

To separate the window from the anchor move the mouse pointer
to the upper margin. Click and hold the left mouse button. Move
the window a small distance towards the center of the screen. Now
release the left mouse button. Now you need to move the library
window to the lower right and the project window to the lower left.
Once a window has been separated from the anchor it can be
moved freely.

To re-anchor the window move the mouse pointer to the upper


margin. Click and hold the left mouse button. Move the window as
far as possible to the right or the left. Now release the left mouse
button. This window snaps into place. This enables you to anchor
the library window to the right and the project window to the left,
for example. You can also anchor both windows on the same side.
In this case you can move the desired window into the foreground
by clicking the associated tab.

4.2 Automatic show and hide

The tabs offer an additional, practical function: Automatically


showing and hiding the library or project window. Click the associ-
ated vertical tab Library or Project at the edge of the window.
This causes the window to be hidden providing a larger area for the
drawing. In order to make the window visible again move the
mouse pointer over the tab; the window opens once again. As soon
as you have performed your operations in this window and move
the mouse pointer to a circuit window the library window and / or

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 31


the project window are automatically hidden. To deactivate the
function click the associated tab again (this then appears de-
pressed).

32 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM


Edit circuit

Chapter 5
5. Edit circuit

5.1 Insert and arrange symbols

You can insert symbols into the symbol window being edited using
the dialog window Find Symbol and by means of the libraries. You
can also transfer objects from every other window by selecting
them and dragging them to the desired window. Alternatively you
can also utilize the clipboard by selecting the items, choosing the
Copy menu item on the Edit menu, bringing the target window
into the foreground and selecting the Paste menu item on the
Edit menu. Using the mouse pointer to drag objects from one
window to another copies them. Dragging the objects from one
position to another within a window moves them. In order to copy
within a window you need to hold down the Shift key while
moving the mouse pointer. You can recognize operation by the
shape of the mouse pointer. During a move-operation a cross with
arrows appears, when copying a plus symbol also appears in
the lower right-hand corner of the cross.

5.2 Connect connectors / ports

In order to connect two component connectors with a line move the


mouse pointer to the component connector. You can recognize a
connector by the small circle at the end of a symbols connection
line. As soon as you have touched the line the mouse pointer trans-
forms into a crosshair .

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 33


Figure 5/1: Mouse pointer as a crosshair over a component con-
nector.

Now press the left mouse button and move the mouse pointer
to the connector which you wish to connect with the first.

You can recognize when you are over the connector by the shape of
the mouse pointer . If the mouse pointer is over a connector
which is already connected to a line then the prohibited sign
appears and no line can be connected.

Release the mouse button once you have touched the second
connector.

FluidSIM automatically lays a line between the two connectors.

34 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM


Figure 5/2: Line between two connectors

Support points can be set when dragging lines. To do so simply


release the mouse button while dragging the line and click the
desired points. The line is completed as soon as you click a second
connector or the same point twice. You can cancel the action by
pressing the Esc key or the right mouse button.

5.3 Automatically connect connectors

FluidSIM supports two methods of automatically connecting con-


nectors. The first is to drop a symbol on an existing line. To be able
to use this method, the symbol must have at least two connectors
that precisely fit onto one or more existing lines and the lines that

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 35


will be produced must not cross the symbol. The following two
illustrations show this function.

Figure 5/3: Circuit before the connectors are automatically con-


nected

Figure 5/4: Circuit after the connectors are automatically connected

Another method of automatically connecting connectors is to


position symbols so that their connectors can be horizontally or
vertically connected with free connectors from other symbols. After
the symbol has been dropped the corresponding lines are automat-
ically drawn if they do not cross any symbols. The free connectors
can also be T distributors.

You can define how different objects' connectors are automatically


connected in the Connector Links tab under the Options... menu

36 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM


item from the Tools menu. The following two illustrations show
this function.

Figure 5/5: Circuit before the connectors are automatically con-


nected

Figure 5/6: Circuit after the connectors are automatically connected

5.4 Insert T distributor

You do not need to utilize a special symbol in order to insert a T


distributor. FluidSIM automatically inserts a T distributor when you
lay a component connection on a line or lay a line segment to a
connection. If you wish to connect two lines then you can also draw
one line segment to another; FluidSIM then inserts two T distribu-
tors and connects these with a new line.

Move the mouse points to a connector and press the left


mouse button.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 37


As soon as you touch the line the mouse pointer transforms into a
crosshair .

Release the mouse button once you have touched the desired
point on the line.

FluidSIM inserts a T distributor and automatically lays a line.

Figure 5/7: Line connection with inserted T distributor

Every T distributor can connect up to 4 lines with each other.

The default representation for the T distributor can be selected via


the corresponding drop-down list on the toolbar.

You can customize the representation of the T distributor by dou-


ble-clicking the T distributor or highlighting the T distributor and
selecting the Properties... menu item from the Edit menu. The

38 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM


Properties dialog window opens. Select the Representation
tab.

Figure 5/8: T distributor dialog window. Tab: Representation

T distributor Defines the representation of the basic T distributor. Here you can
select whether the distributor should be represented as a filled
circle or a simple intersection.

Cross-Link Defines that the T distributor should be represented as an electric


link. This representation has a knock-on effect on the connected
lines, which are automatically marked as links.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 39


Junction Defines that the T distributor should be represented as an electric
junction. This representation has a knock-on effect on the termi-
nals' target search. With a junction, the target in the direction of a
straight line or right angle is found first and then the target via an
angled branch.

5.5 Move lines

Once you have joined two connectors you can then adjust the
length of the lines. You can move the line segments in parallel by
moving the respective line segment. You can see when you have
touched the line on the basis of the line-selection shape of the
mouse pointer.

Press the left mouse button and move the line segment or-
thogonally to the desired position.

Figure 5/9: Moving a line segment

Release the left mouse button; FluidSIM adjusts the adjoining


line segments in such a way that they remain connected.

If you move a line segment with is directly connected to a compo-


nent connector then FluidSIM may insert additional line segments
in order to prevent gaps.

40 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM


If you move a line segment that is horizontally or vertically con-
nected with other line segments via T distributors then these line
segments are moved together with the T distributors.

Figure 5/10: Moving multiple line segments

Figure 5/11: Moving multiple line segments

If you only want to move the individual line segment in the case
described above then release the mouse button after you highlight
the line segment. Click the segment again and move it while keep-
ing the mouse button pressed.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 41


Figure 5/12: Moving an individual line segment

5.6 Direct connection via straight connection line

Normally connection lines in technical circuits are always drawn


orthogonally. However, it can sometimes be desirable to create a
direct connection between two connectors via a diagonal line. To
achieve this, first connect the two connectors in the standard way.
Then select any segment on the line and right-click to open the
context menu. Select Straight connection line to create a direct
connection.

Figure 5/13: Direct connections between two connectors

To switch back to an orthogonal line, open the context menu again


and select Orthogonal line segments.

42 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM


5.7 Define the characteristics of lines

Lines, like other symbols, can be assigned an identification, cata-


logue properties and user-defined properties. You can find further
information on this under Component attributes in the Properties
dialog window.

You can also define the style, color and drawing layer of the lines by
double-clicking a line segment or highlighting the line segment and
selecting the Properties... menu item from the Edit menu. The
Line Properties dialog window opens. Select the Drawing Properties
tab in this window. The settings are applied to the entire line sec-
tion as far as the next connector or T distributor.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 43


Figure 5/14: Line Properties dialog window: defining the properties
of a pneumatic or electric line

Layer Sets the drawing layer of the line.

Color Sets the color of the line.

Line Style Sets the line style of the line.

Line Width Sets the line thickness of the line.

Note: Working lines are typically displayed as solid lines, pilot lines
as dashed lines.

Please note that the way the lines are displayed during the simula-
tion depends on the physical status of the lines. The colors, line
styles, and line thicknesses will vary according to pressure, flow,

44 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM


voltage, etc.. You can define how the lines are displayed during the
simulation on the Simulation tab under Options... in the Tools
menu. When you exit Simulation Mode, the lines once again appear
the way you defined them in Edit Mode.

5.8 Delete line

To delete a line you can either highlight an associated line segment


and press the Del key or select the Delete menu item from the
Edit menu or highlight a component connector and press the
Del key. In these cases it is the line rather than the connector
itself that is deleted.

If you delete a T distributor which three or four lines are attached to


then all of the lines are deleted. If, on the other hand, only two lines
are connected then only the T distributor is deleted and the two
lines combined into one.

5.9 Set the properties of the connectors

You can assign a component connector an identification and a


blanking plug or silencer by double-clicking on the connector or by
selecting the connector and choosing the Properties... menu item
on the Edit menu. The Connector dialog window then opens.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 45


Figure 5/15: Connector dialog window: setting the properties of a
connector

Identification You can enter a text identifying this connector into the input line. If
the Display option is activated then the identification is displayed
in the circuit diagram.

Whether or not the identification is actually displayed depends on


the option selected under Show Connector Descriptions .

Display quantity values During the simulation, the calculated quantity values can be dis-
played not only with specialized measuring devices, but also direct-
ly at the connectors. For a quick overview, you can use View
Quantity Values... to show all values at all connectors with a
single click. As this is generally fairly confusing, you can also
choose to view the quantity values at selected connectors only. For
more details, see "Displaying quantity values".

Terminator Open the symbol list containing connector terminators by clicking


the button using the arrow. Select a suitable silencer or a blanking
plug.

Note: Please note that this symbol list is only available if a line is
not connected to the connector in question. If you wish to connect a

46 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM


line to a sealed connector you first have to remove the blanking
plug or silencer. To do this select the empty field in the symbol list
with the connector terminators. The alignment of the connector
terminator can be set via the radio buttons.

5.10 Configure a way valve

If you require a certain valve which you cannot find in the standard
FluidSIM library you can create your own valve symbol with the
help of the valve editor.

Insert a 5/n-way valve into a circuit window from the Stand-


ard Symbols / Pneumatic Symbols / Valves / Configurable Way
Valves library (insert a hydraulic valve in case of FluidSIM-H).

To set the valve body and the actuation types of the way valves
double-click the valve. The dialog window Properties then opens.
Click the Configure Valve tab to access the valve editor.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 47


Figure 5/16: Properties dialog window: Configure Valve tab

Left Actuation Right Actua- You can select the actuation types of the valve from the Manual-
tion ly, Mechanically and Pneumatically/Electrically (Hydraulical-
ly/Electrically resp.) categories for both sides of the valve. Click
the button with the mouse pointer and select a symbol element. A
valve can have multiple actuation types at the same time. If you do
not want an actuation type from a category then select the empty
field in the list. You can also define whether each side should have
a spring return, pilot control, pneumatic spring or external supply.

Valve Body A configurable valve can possess a maximum of four switching


positions. One valve body can be selected for each switching posi-
tion. Click the associate button with the mouse points to open the

48 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM


symbol elements list. Select a symbol element for each switching
position. If you want to use less than four switching positions then
select the empty field on the list for the positions not required.

Initial Position Here you set which switching position the valve should use in the
normal position. Note: When determining this setting ensure that it
does not conflict with a possible spring return.

Dominant Signal This provides a graphical identification of whether the right or left
signal should dominate in the event of equally strong signals.

External Supply This creates an additional connector for connecting the external
supply for the controller.

5.11 Configure cylinders

If you require a certain cylinder which you cannot find in the stand-
ard FluidSIM library you can create your own cylinder symbol with
the help of the cylinder editor.

Insert a double-acting cylinder into a circuit window from the


Standard Symbols / Pneumatic Symbols / Pneumatic Drives /
Configurable Cylinders library. In the case of FluidSIM-H, se-
lect a hydraulic cylinder accordingly.

To configure the cylinder double-clock on the cylinder. The dialog


window Properties then opens. Click the Configure Cylinder tab.
This brings you to the cylinder editor.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 49


Figure 5/17: Properties dialog window: Configure Cylinder tab

Cylinder Type Click the button with the mouse pointer to open the symbol ele-
ments list. Select a cylinder type. Set whether the cylinder should
be single-acting or double-acting.

Return Spring Specifies whether a spring for the return should be inserted into the
right or left cylinder chamber.

Piston Click the button with the mouse pointer and select a symbol ele-
ment for the piston. Set whether the cylinder should possess end
position cushioning and whether this should be adjustable.

50 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM


Piston Rod Click the button with the mouse pointer and select a symbol ele-
ment for the piston rod.

Piston Position Using the slider you can specify the relative piston position in 25 %
steps. 0 % stands for the completely retracted and 100 % extended
piston.

5.12 Group symbols

If you wish to combine multiple symbols into a group select these


and choose the Group menu item on the Edit menu. Groups can
also be nested, i.e. already grouped objects can be grouped again.

A group primarily serves as a drawing aid and does not represent


any new components. Every element in a group is included in a
parts list in exactly the same way as without being grouped. Dou-
ble-clicking on a group element opens the dialog window Proper-
ties of group element clicked.

If you wish to combine multiple symbols into a new component with


its own attributes create a macro object.

5.13 Create macro objects

If you wish to combine multiple symbols into a new component with


its own attributes then highlight these and select the Create Mac-
ro Object menu item from the Edit menu. This creates a new
macro object. Macro objects are included in the parts lists as inde-
pendent components. The original symbols are removed from the
parts lists. It is no longer possible to edit their component attrib-
utes.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 51


5.14 Delete symbol groups and macro objects

To delete a group or a macro object select the group or the macro


object and select the Ungroup/Break Off menu item from the
Edit menu. This always deletes the outermost group. In order to
delete nested groups you must repeat the operation.

5.15 Align symbols

To align objects with each other, select these and choose the de-
sired orientation from the Align menu item on the Edit menu or
click the appropriate button on the toolbar.

5.16 Mirror symbols

The symbols can be both horizontally and vertically mirrored. Select


the desired mirror axis from the Mirror menu item on the Edit
menu or click the appropriate button on the toolbar. If you
select multiple objects at the same time then every object will be
mirrored separately. If you wish the operation to use a common
mirror axis then group the objects before the operation.

The geometrical properties can be entered directly via the Drawing


Properties tab. Enter a minus sign in front of the corresponding
scaling factor in order to mirror the symbol.

52 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM


5.17 Rotate symbols

The symbols can be rotated in 90 degree steps or with the help of


the mouse pointer. To rotate objects in 90 degree steps, select the
desired angle from the Rotate menu item on the Edit menu or
click the appropriate button on the toolbar. If you select multiple
objects at the same time then every object will be rotated separate-
ly. If you wish the operation to use a common axis of rotation then
group the objects before the operation.

You can also rotate symbols with the help of the mouse pointer by
clicking and dragging the edge of the symbol. In order to do this
FluidSIM must be in Enable Rotate mode. This mode can be
activated or deactivated using the Enable Rotate menu item from
the Edit menu or by clicking the corresponding button on the
toolbar.

Note: Activating the Enable Scale mode deactivates the Enable


Rotate mode and vice versa.

In Enable Rotate mode click the edge of the symbol and hold
down the mouse button.

Figure 5/18: Rotate symbol

The current angle of rotation and guides are displayed.

Hold down the mouse button and move the mouse pointer
until the desired angle of rotation is achieved. The angle
changes in 15 degree steps.

Note: If you also press the Shift key then you can rotate the
symbol steplessly.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 53


Figure 5/19: Rotate symbol

The angle of rotation can also be entered directly in the properties


dialog window in the Drawing Properties tab.

Note that the rotation of the drawing has no effect on the simula-
tion. If you want a load to be raised, for example, you need to enter
the desired angle under Mounting angle in the component pa-
rameters.

5.18 Scale symbols

The component symbols can be scaled with the help of the mouse
pointer. In order to do this FluidSIM must be in Enable Scale
mode. This mode can be activated or deactivated using the Enable
Scale menu item from the Edit menu or by clicking the corre-
sponding button on the toolbar.

Note: Activating the Enable Scale mode deactivates the Enable


Rotate mode and vice versa.

In Enable Scale mode click the edge or corner of the symbol


and hold down the mouse button.

54 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM


Figure 5/20: Scale symbol

The current scaling relationship to the current original size is dis-


played.

Hold down the mouse button and move the mouse pointer
until the desired size is reached. The scaling relationship is
changed in 0.25 steps. Note: If you also press the Shift key
then you can scale the symbol steplessly.

Figure 5/21: Scale symbol

You can simultaneously mirror the symbol by moving the mouse


pointer over the middle of the symbol to the opposite side.

Figure 5/22: Mirror symbol

The scaling factor can also be entered directly in the Properties


dialog window in the Drawing Properties tab.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 55


Drawing frame

Chapter 6
6. Drawing fra me

In FluidSIM drawing frames are circuit diagrams which consists of


a title block and the frame with the field divisions. They can also be
displayed in other circuit diagrams. Existing CAD drawing frames
can be imported using the DXF import menu item on the File
menu. No order to make a drawing frame usable in different pro-
jects and circuit diagrams a number of texts in the title block must
be editable. These texts are Author, Creation date, Project name,
Page name and Page number, for example. In FluidSIM these are
text components with Attribute Link.

6.1 Editable labels

Texts in the title block of a drawing frame are text components. You
can use the imported texts or insert new text components at the
desired positions. Editable texts are text components with Attribute
Link. These texts are replaced by the corresponding attribute val-
ues of the project and the circuit.

Double-click a text component to open the Properties dialog


window.

Enter the name of the attribute to be linked, e.g. creator, in


the text field and activate the Attribute Link option.

Note: You can also use an imported text as an attribute name.

The attribute name is utilized as a placeholder. These attributes are


displayed in angle brackets in the circuit diagram with the draw-
ing frame. These attributes are replaced by the corresponding
attribute values when using the drawing frame in a project or circuit
diagrams. Edit the attribute values in the Properties dialog window
of the project or the circuit diagram. Clicking on a text component
of the drawing frame opens the Properties dialog window of the
project or the circuit which contains the attribute which the text
component refers to.

56 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM


6.2 Use a drawing frame

Drawing frames can be copied into a project and/or a circuit dia-


gram. Insert the drawing frame via the Properties dialog window of
a project or a circuit.

All of the objects belonging to a drawing frame are inserted into the
circuit diagram as a copy. Changing the file with the drawing frame
at a later date does not have any effect on the circuit diagram which
the drawing frame was inserted into.

When copying the objects belonging to the drawing frame all of the
attributes are generated with the drawing frames text components
refer to and which do not exist in the project or circuit.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 57


Figure 6/1: Page dialog window: inserting a drawing frame

Inherit From Project If this option is activated then the drawing frame specified in the
project is copied into the circuit. The path and the file used are
displayed in the Frame File line.

Pick... This button opens a dialog window in which an included frame can
be selected. These frame files are located in the frm directory and
are compiled in the project file frames.prj.

Edit Opens the frame file for editing.

Remove Local Frame Removes the drawing frame from the circuit. The drawing frames
attributes remain attributes of the project or circuit.

58 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM


Reload Frame Attributes When inserting a drawing frame the attributes of the text compo-
nents of the drawing frame are listed. These attributes are saved
with the project or the circuit drawing and can be edited and delet-
ed. The Reload Frame Attributes button reloads all of the attrib-
utes from the drawing frame, thus updating the attribute list of the
project or the circuit drawing.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 59


Figure 6/2: Select Drawing Frame dialog window

All of the available frame files are displayed as a tree on the right-
hand side. The desired drawing frame can be selected in this tree.
The drawing frame is then displayed in the preview. In addition the
Attributes list displays all of the attributes of the texts from the
drawing frame which were defined as links.

60 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM


Browse... Opens a dialog window to select a circuit file to be used as a frame.

6.3 Page dividers

A circuit diagram or page can be logically divided into rows and


columns, which can be labeled with numbers or letters. These page
dividers are usually shown in the drawing frame and serve as a
means of orientation within the page. Above all they allow the
current paths (columns) of contacts to be specified in the contact
images.

The graphical representation of the page dividers matches the


logical page dividers in the drawing frames provided. The logical
page dividers can be shown and hidden via the Show Page Divid-
ers menu item from the View menu or via the button. They
are displayed at the left-hand as well as the upper edge of the
circuit window.

To be able to display and edit page dividers, you need to activate


the Expert Mode option in the Options... menu.

If the page dividers are visible you can customize them using the
mouse so that they match the graphical representation of the
drawing frame, for example. This customization can be done in
different ways:

Click and hold the mouse buttons in a column or row to move


the entire column or row.

Figure 6/3:

Click and hold the mouse buttons at the outer margin of a


column or row to move the margin of the column or row.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 61


Figure 6/4:

The opposite margin is not moved and the columns or rows are
resized proportionally.

Click and hold the mouse buttons at the margin of an inner


division in a column or row to move the margin of the column
or row.

Figure 6/5:

In this case only the adjacent columns or rows are resized.

Columns and rows can be inserted and removed using the and
buttons.

The label type and the number of rows and columns can be defined
using the button. The settings are saved as page properties. The
following dialog window is opened:

62 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM


Figure 6/6: Page dialog window, Page Dividers tab

Adopt from drawing frame Selecting this option only makes senses for pages that do not
represent drawing frames. This option must be deactivated if the
current page represents a drawing frame that is to be inserted into
other pages later.

If this option is activated then all settings that have been defined in
the drawing frame will be adopted.

Adopt from current paths When this option is activated, the page dividers are automatically
derived from the current paths of the electrical circuit. You can
show or hide automatic current path numbering via the Display
Current Path Numbering menu.

Setup manually Permits manual division of the rows and columns.

Rows Defines the settings for the horizontal rows.

Columns Defines the settings for the vertical columns.

Number Defines the number of page dividers.

Numbering Numbers, lowercase letters or uppercase letters can be used for


numbering.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 63


First Item Defines the first numbering item. The numbering will be continued
on analogously from this item.

Descending Order Changes the numbering order.

Reset Resets the page dividers to default values.

64 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM


Additional tools for creating drawings

Chapter 7
7. Additional tools for creating dr awings

7.1 Drawing tools

7.1.1 Grid

For arranging the symbols and laying the lines it is often practical to
show a point or line grid. You can activate or deactivate the display
of the grid using the Show Grid menu item from the View menu.
You can also define further grid settings in the General tab under
the Options... menu item from the Tools menu.

In order to simplify handling the connectors snap into place when


they are close to a grid line. This makes it easier to find the precise
position when moving the connectors.

Note: The grid snap function may not be desired as it prevents free
positioning. In this case you can hold down the Ctrl key during
the moving operation; this temporarily deactivates the grid snap
function.

7.1.2 Alignment lines

Connectors between symbols should be exactly horizontal or verti-


cal wherever possible. Then they can be connected with a straight
line.

FluidSIM supports the exact positions firstly via the grid snap and
secondly via automatically displaying red alignment lines while
moving the selected objects.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 65


Open a circuit file which contains multiple objects. Select one
of these and slowly move it back and forth above and next to
other objects.

Observe the dashed red lines which appear when two or more
connectors lie above each other.

Figure 7/1: Automatically display the alignment lines

In order to simplify handling the connectors snap into place when


they are close to an alignment line. This makes it easier to find the
precise position when moving the connectors.

Note: The grid snap function may not be desired as it prevents free
positioning. In this case you can hold down the Ctrl key during
the moving operation; this temporarily deactivates the alignment
lines and the grid snap function.

7.1.3 Object snap

Various snap points can be activated for precise drawing. During a


drawing operation the mouse pointer snaps into place as soon as it
is close to a snap point. The following snap functions are available:

Snap to Grid

Snap to Connector

66 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM


Snap to End Point

Snap to Mid Point

Snap to Centre

Snap to Intersection

Press and hold the Ctrl key during a drawing operation to tempo-
rarily deactivate the object snap function.

To be able to use object snap, you need to activate the Expert


Mode option in the Options... menu.

7.1.4 Rulers

The rulers can be shown and hidden via View Show Rulers .
They are displayed at the left-hand as well as the upper edge of the
circuit window.

To be able to use the rulers, you need to activate the Expert Mode
option in the Options... menu.

7.2 Drawing levels

FluidSIM supports 256 drawing levels which can be shown / hidden


and locked / unlocked individually. In addition you can also define
the color and line thickness for every drawing level. Using the
Drawing Layers... menu item on the View menu you can set the
properties of the individual layers and also insert a description.

Note: The drawing frame is located on layer 0 by default.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 67


Figure 7/2: Drawing Layers dialog window

The drawing layer settings can be copied over as default settings


from the current circuit using the Inherit From Page button.

You can select the drawing layer where newly inserted objects
should be placed under Default Layer . If you do not want the
symbol layer to be changed when objects are inserted then select
the Preserve Object Layer option.

Objects located on a drawing layer for which the Edit option is


deactivated are visible but cannot be highlighted and therefore
neither moved nor deleted. This enables you to lock a drawing
frame, for example, if it was inserted manually and not via the
Properties dialog window for the circuit or project. In order to still
be able to edit objects on layers of this type you must activate the
Edit option for the corresponding layer.

68 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM


Drawing layers for which the Display option is deactivated are
neither visible nor can they be edited.

7.3 Cross-references

Cross-references serve to link connected parts of a circuit drawing


when the entire drawing is spread across multiple pages. This
allows lines to be interrupted, for example, and continued on an-
other page.

FluidSIM offers two types of cross-references. Paired cross-


references consist of two cross-reference symbols that reference
each other. The two cross-reference symbols are linked via a
unique label that is entered for both symbols.

The option also exists to reference any object within a project from
a cross-reference symbol. The cross-reference is uni-directional in
this case: from the cross-reference to the target object. This allows
several cross-references to reference the same object.

Both types enable you to jump directly from a cross-reference to


the associated target. With the paired cross-reference the target is
the corresponding cross-reference, otherwise an object.

You jump to the corresponding target either using the Jump to


Target button in the properties dialog window for the cross-
reference symbol or by highlighting the cross-reference and select-
ing the Jump to Target menu item from the context menu.

The circuit drawings involved must belong to the same project.

Open the Cross-reference dialog window from the Edit menu and
the Properties... menu item. Alternatively you can open this
dialog window by double-clicking the cross-reference symbol or
using the Properties... context menu.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 69


Figure 7/3: Cross-reference dialog window

Text This text is displayed in the cross-reference

Label Defines the labels via which the linked cross-references are identi-
fied.

Link If this option is activated then the label entered constitutes a link to
a target object. The cross-reference only works in the direction of
the target object in this case. This option can be combined with the
Show Location option to show the location of the target object.

Target Text If the Show Location option is activated then the location of the
target object will be displayed here. The representation of the
location is defined in the Cross Reference Representation tab in the
properties dialog window for the page or project.

70 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM


If Show Description is activated then the text of the corresponding
cross-reference is displayed for paired cross-references, otherwise
the description of the target object is displayed.

Display Target Text If this option is activated then the above-mentioned text from the
Target Text field is displayed below the text for this cross-reference.

Jump to Target Activating this button opens the circuit window containing the
corresponding cross-reference. The associated symbol is indicated
by an animation.

The font type, text color and alignment of the texts to be displayed
can also be customized.

7.3.1 Create cross-references from symbols

You can generate a cross-reference from one or more symbols. To


do so highlight the corresponding symbols and select the Edit
Create Cross-reference menu item or the Create Cross-reference
menu item from the context menu. The highlighted symbols are
combined into a group that constitutes a cross-reference with two
additional texts. One of these texts shows the label used and the
other the target text for the cross-reference.

7.3.2 Cross-reference representation

The location of the target object can be shown in cross-references.


How it is represented can be specified in the Cross Reference
Representation tab in the properties dialog window for the circuit
or project. The location can be composed from the Page number,
Page, Page Column, Page Row and Object Identification
components. These reference the target object. Separators can be
placed before and after each component. The default representa-
tion is:

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 71


/ Page number. Page Column The description for the page and the
page number are specified in the Properties dialog window for the
circuit.

To be able to use the options for displaying cross-references, you


need to activate the Expert Mode option in the Options... menu.

The page number is a predefined placeholder that can be used in


text components and drawing frames among other things.

Figure 7/4: Cross Reference Representation tab

Inherit From Parent Node Defines whether the representation rules for the parent node
should be applied.

Example A sample location that conforms to the specified rules is displayed


here.

Reset Resets the cross-reference representation to the default setting.

7.3.3 Manage cross-references

All paired cross-references in a project are listed in a dialog window


that is opened using the Project Manage Cross References...

72 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM


menu item. Using this dialog you can jump to all paired cross-
references in the project.

To be able to use the options for managing cross-references, you


need to activate the Expert Mode option in the Options... menu.

Figure 7/5: Manage Cross References... tab

Label Contains the label for the corresponding cross-reference.

Containing Page A page containing the cross-reference in question can be selected


in the drop-down list.

Jump to Target Using this button you can jump to the corresponding cross-
reference.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 73


7.4 Drawing functions and graphical elements

Graphical elements can be inserted into a circuit using the Draw


menu or by activating the drawing function on the toolbar. In order
to prevent you from unintentionally moving other symbols when
drawing you enter a special mode for the drawing function in which
you can only perform the selected drawing functions. After every
drawing operation FluidSIM returns to the normal editing mode. To
insert another drawing element you must select the associated
menu item or the corresponding drawing function on the toolbar
again.

Note: If you wish to draw several elements in a row without leaving


the special drawing mode then you can select the menu item or the
corresponding drawing function on the toolbar while holding down
the Shift key. The drawing mode then remains active until the
menu item or the drawing function is deactivated by selecting it
again or another drawing function is selected without the Shift
key being pressed.

The drawing functions toolbar contains the following buttons:

Switches to the normal editing mode.

Switches to the mode for drawing a line.

Switches to the mode for drawing a polyline.

Switches to the mode for drawing a rectangle.

Switches to the mode for drawing a circle.

Switches to the mode for drawing a ellipse.

Switches to the mode for drawing a text.

Switches to the mode for drawing an image.

Switches to the mode for drawing a conduction line. You can start
by choosing whether you would like to draw a pneumatic, hydrau-
lic, electric, digital, or GRAFCET conduction line.

74 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM


The graphical elements are drawn in the color shown.

The graphical elements are drawn in the line style shown.

The graphical elements are drawn in the line thickness shown.

The line beginnings are drawn with the symbol shown.

The line ends are drawn with the symbol shown.

7.4.1 Interruption/Potential

If conduction lines extend over several pages then the line ends can
be assigned interruptions. Interruptions can be used to define that
a conduction line is only interrupted in the drawing and is contin-
ued somewhere else. An interruption can be assigned an identifica-
tion and linked with another interruption. The location of the linked
interruption can be displayed at the source interruption.

If an electric interruption is used with an electric line then this


interruption is a potential. The use of electric potentials is de-
scribed under Potentials and conduction lines.

You can insert an interruption into an existing line or position it


freely in a circuit.

Select the Interruption/Potential... menu item from the


Insert menu.

A dialog window opens where you can make various settings for
the interruption to be inserted.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 75


Figure 7/6: Interruption/Potential... dialog window

Type of connector Defines whether a fluidic or electric interruption (potential) is to be


inserted.

Define multiple connectors Multiple interruptions can be set one after the other if this option is
active. You can cancel the action by pressing the Esc key.

You can edit the properties for an interruption by double-clicking it.


The following dialog window opens.

76 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM


Figure 7/7: Interruption/Potential dialog window

Layer Defines the drawing layer for the interruption.

Identification Defines the identification for the interruption. The identification will
be displayed in the circuit if the Display option is active.

Target Interruptions can reference each other in pairs. The counterpart


interruption can be selected from a list or entered directly in the list
box. Browse... opens a dialog window where all interruptions are
displayed in a tree and can be selected. Only interruptions that are
not linked will be shown in the list if the Only Free Interrup-
tions/Potentials option is active.

Jump to Target If the interruption is linked with another interruption then this
button can be used to jump to the counterpart interruption.

Show Location If this option is activated and the interruption is linked with another
interruption then the location of the counterpart interruption will be
displayed as a page coordinate (e.g. page number/column).

Representation A symbol that defines the representation of the interruption can be


selected from a list. To illustrate the representation the relevant
symbol always additionally shows the intersection of two lines.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 77


7.4.2 Conduction line

A conduction line is drawn by defining two end points. A pneumatic


or electric line of this type consists of two connectors with a line
between them. Both connectors can be used as the starting point
for further connections. The conduction lines can only be drawn
horizontally or vertically.

You open a dialog window where you can make various settings for
the line to be dragged using the Insert Conduction Line... menu
item or the button on the toolbar.

78 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM


Figure 7/8: Conduction Line... dialog window

Type of connection line Selects the conduction line type. The following are available:
Pneumatic and Electric.

Define multiple lines Multiple conduction lines can be set one after the other if this
option is active. You can cancel the action by pressing the Esc
key.

If multiple conduction lines with the same distance between them


are to be drawn horizontally or vertically then change the number in
the Number of lines field. You specify the distance to be main-
tained between the lines using Distance.

Under Start Point Appearance and End Point Appearance you


can define the representation of the respective end point. If the
Display Identification option is selected then the identification for

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 79


the start point is displayed. In order to guarantee that the same
identification is displayed for the start point and the end point, a
text reference for the start point is displayed for the end point
instead of its identification.

Interruptions are used as end points for conduction lines.

After confirming the dialog window you switch to a special mode


where you define the end points of the line with two consecutive
mouse clicks. Alternatively you can also draw a line by clicking and
dragging.

An electric conduction line can constitute a potential line. This is


described under Potentials and conduction lines.

7.4.3 Line

A line is drawn by defining two points. In contrast to a conduction


line this line is purely a drawing element. As such it can be drawn
with any desired angle but does not allow connections with pneu-
matic or electric connectors.

The line-specific properties can be defined in the Drawing Proper-


ties tab of the Properties dialog window for the line:

80 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM


Figure 7/9: Properties dialog window for a line: Drawing Properties
tab

Start Point Defines the x/y coordinate of the start point.

End Point Defines the x/y coordinate of the end point.

Scale Defines the scaling in the x or y direction.

Rotation Defines the angle of rotation in degrees.

Override Color Defines the color of the drawing element.

Line Style Defines the line style.

Line Width Defines the line thickness.

Start Cap Defines how the beginning of the line is displayed.

End Cap Defines how the end of the line is displayed.

Background Sets the location of the drawing element to the background. This
means that all of the circuit symbols are on top of this. For example
symbols are not covered by filled drawing elements.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 81


Foreground Sets the location of the drawing element to the foreground. This
means that all of the circuit symbols are underneath this. For ex-
ample symbols are covered by filled drawing elements.

Reset Reset the settings to the default values.

7.4.4 Polyline (set of connected lines)

A polyline (also called a set of connected lines or polygonal chain)


is drawn by defining two or more points. Each mouse click sets a
further vertex. The polyline is ended by clicking the same point
twice.

The properties of the polyline can be defined in the Drawing Proper-


ties tab in the Properties dialog window:

Figure 7/10: Properties dialog window for a polyline: Drawing


Properties tab

Scale Defines the scaling in x or y direction.

82 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM


Rotation Defines the angle of rotation in degrees.

Override Color Defines the color of the drawing element.

Line Style Defines the line style.

Line Width Defines the line width.

Start Cap Defines how the beginning of the line is displayed.

End Cap Defines how the end of the line is displayed.

Background Sets the location of the drawing element to the background. This
means that all of the circuit symbols are on top of this. In particular
it means that symbols are not covered by filled drawing elements,
for example.

Foreground Sets the location of the drawing element to the foreground. This
means that all of the circuit symbols are underneath this. In particu-
lar it means that symbols are covered by filled drawing elements,
for example.

To change the vertices of a polyline or to set new vertices switch to


the polyline editing mode by selecting the Edit Edit Poly Line
menu item or activating the button on the toolbar.

You can move the existing vertices by clicking and dragging. The
mouse pointer changes to when you mouse over an existing
vertex. If the mouse pointer is over a line without a vertex is
displayed and a new vertex is inserted as soon as you click.

7.4.5 Rectangle

A rectangle is drawn by defining two diagonally opposite corner


points.

The rectangle-specific properties can be defined in the Drawing


Properties tab of the Properties dialog window for the rectangle:

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 83


Figure 7/11: Properties dialog window for a rectangle: Drawing
Properties tab

Scale Defines the scaling in the x or y direction.

Rotation Defines the angle of rotation in degrees.

Override Color Defines the color of the drawing element.

Fill Area Fills the rectangle with the color listed.

Line Style Defines the line style.

Line Width Defines the line thickness.

Background Sets the location of the drawing element to the background. This
means that all of the circuit symbols are on top of this. For example
symbols are not covered by filled drawing elements.

Foreground Sets the location of the drawing element to the foreground. This
means that all of the circuit symbols are underneath this. For ex-
ample symbols are covered by filled drawing elements.

84 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM


7.4.6 Circle

A circle is drawn by defining a middle point and a radius. You can


draw a circular arc by subsequently entering the beginning and
final angles into the Drawing Properties tab in the Properties dialog
window of the circle.

The circle-specific properties can be defined in the Drawing Proper-


ties tab of the Properties dialog window for the circle:

Figure 7/12: Properties dialog window for a circle: Drawing Proper-


ties tab

Scale Defines the scaling in the x or y direction.

Arc Defines the starting and final angles of a circular arc.

Rotation Defines the angle of rotation in degrees.

Override Color Defines the color of the drawing element.

Fill Area Fills the circle with the color listed.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 85


Line Style Defines the line style.

Line Width Defines the line thickness.

Start Cap Defines how the beginning of the line is displayed.

End Cap Defines how the end of the line is displayed.

Background Sets the location of the drawing element to the background. This
means that all of the circuit symbols are on top of this. For example
symbols are not covered by filled drawing elements.

Foreground Sets the location of the drawing element to the foreground. This
means that all of the circuit symbols are underneath this. For ex-
ample symbols are covered by filled drawing elements.

7.4.7 Ellipse

An ellipse is drawn by defining a middle point and two radii with


parallel axes. You can draw an ellipse by subsequently entering the
beginning and final angles into the Drawing Properties tab in the
Properties dialog window of the ellipse.

The ellipse-specific properties can be defined in the Drawing Prop-


erties tab of the Properties dialog window for the ellipse:

86 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM


Figure 7/13: Properties dialog window for an ellipse: Drawing
Properties tab

Scale Defines the scaling in the x or y direction.

Arc Defines the starting and final angles of an ellipse.

Rotation Defines the angle of rotation in degrees.

Override Color Defines the color of the drawing element.

Fill Area Fills the circle with the color listed.

Line Style Defines the line style.

Line Width Defines the line thickness.

Start Cap Defines how the beginning of the line is displayed.

End Cap Defines how the end of the line is displayed.

Background Sets the location of the drawing element to the background. This
means that all of the circuit symbols are on top of this. For example
symbols are not covered by filled drawing elements.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 87


Foreground Sets the location of the drawing element to the foreground. This
means that all of the circuit symbols are underneath this. For ex-
ample symbols are covered by filled drawing elements.

7.4.8 Text

A text is inserted at the position of the mouse pointer by clicking.


The dialog window Properties for entering the text and setting the
attributes then opens.

7.4.9 Image

An image is inserted at the position of the mouse pointer by click-


ing. The dialog window for selecting an existing image file then
opens.

Large background images can massively decrease the processing


speed as the screen has to be re-drawn whenever symbols are
moved or edited.

The image-specific properties can be defined in the Drawing Prop-


erties and Picture tabs of the Properties dialog window for the
image:

88 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM


Figure 7/14: Properties dialog window for an image: Drawing
Properties tab

Scale Defines the scaling in the x or y direction.

Rotation Defines the angle of rotation in degrees.

Override Color Defines the color of the drawing element.

Background Sets the location of the drawing element to the background. This
means that all of the circuit symbols are on top of this. For example
symbols are not covered by filled drawing elements.

Foreground Sets the location of the drawing element to the foreground. This
means that all of the circuit symbols are underneath this. For ex-
ample symbols are covered by filled drawing elements.

File Defines the image file for the image.

External Link When this option is active FluidSIM only saves a link to the image
file. However if this option is deactivated then the image is embed-
ded in the circuit diagram. This is the preferable variant if you wish
to pass on or archive the circuit diagram.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 89


7.5 Check drawing

You can use Check Drawing in the Page menu to have FluidSIM
check your drawing for possible drawing errors. FluidSIM displays
the following messages where necessary:

Duplicated identification labels

Unresolved link targets

Superimposed objects

Lines through connectors

Open connectors

Duplicated cross-reference labels

Superimposed lines

Cyclic object references

Objects outside the drawing area

Missing translations

Ambiguous terminal strip references

Unassigned cables

Unassigned terminals

Duplicated terminal references

Two digital outputs are connected to each other.

Digital loop detected.

Connection errors found in the GRAFCET diagram.

If messages are displayed then the corresponding objects are


selected after confirmation in the dialog window.

90 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM


Simulating with FluidSIM

Chapter 8
8. Simulating with FluidSI M

8.1 Simulation of existing circuits

FluidSIM comes supplied with a series of functional circuits. These


include circuits used in training material, which are discussed in
more detail in the various basic and advanced level workbooks
from Festo Didactic GmbH & Co. KG.

You can find these sample circuits under Circuits for exercises
(TP)... in the Didactics menu. The names of the folders match
those of the corresponding workbooks from Festo Didactic GmbH &
Co. KG. The sample circuits can be edited and simulated as desired.
However, bear in mind that your modifications may alter the func-
tion of the circuit and consequently also the training material. We
therefore recommend saving any modified sample circuits under a
different name or in their own folder.

Open the circuit demo1 and start the simulation via Execute
Start or using the symbol .

FluidSIM switches to Simulation Mode and starts the simulation of


the circuit. In Simulation Mode, the mouse pointer changes into the
hand symbol .

At the start of the simulation, FluidSIM first creates a physical


model of the entire system. Construction of the model is usually a
complex operation, which can take several seconds depending on
the complexity of the circuit and the speed of the computer. Con-
tinuous calculation of the model using mathematical methods then
follows. It cannot always be guaranteed that the subsequent dy-
namic simulation will take place in real time. The percentage of real
time achieved is displayed by FluidSIM in the status bar at the
lower edge of the screen.

The line animation display during the simulation can be customized


in Options... .

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 91


The exact numerical values for the pressures, flow rates, voltages,
and currents are displayed on the connected measuring devices.
Section "Displaying quantity values" describes how you can dis-
play the numerical values for all or some quantity values in the
circuit even without measuring devices.

The simulation is based on physical models which were calibrated


with the pneumatic, hydraulic, and electric components in the Festo
Didactic GmbH & Co. KG equipment sets. The calculated values
should therefore closely match the values recorded by your meas-
urements. When comparing the two, please bear in mind that in
practice, measurements can be subject to large fluctuations. The
reasons for differences range from component tolerances and tube
length, to air and oil temperatures.

The calculation of the quantity values also forms the basis for the
exact, real-time-proportional animation of the cylinders.

Real-time-proportional guarantees the following property: If in


reality a cylinder moves twice as fast as another one, for example,
that will also occur in the animation. In other words, the real-time
ratio is retained in the simulation.

Manually operated valves and switches can be switched by clicking


them with the mouse:

Move the mouse pointer onto the left-hand switch.

The mouse pointer changes into a hand with pointing finger


indicating that the switch beneath can be flipped.

Click the switch.

When you click a manually operated switch, its real behavior is


simulated. In our example, the clicked switch is closed and recalcu-
lation begins automatically. Following the calculation, the new
pressure and flow values are displayed and the cylinders move into
their initial positions.

The switching of components is only possible while a simulation is


running ( ) or when a simulation is paused ( ).

92 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM


If you wish to simulate another circuit, you do not need to close the
currently loaded circuit. FluidSIM allows you to have multiple
circuits open at the same time and to simulate them either sepa-
rately from one another or as a total system within one project.

Click or Execute Stop to switch the currently active


circuit from Simulation Mode to Edit Mode.

When you switch from Simulation Mode to Edit Mode, the non-
adjustable components are automatically reset to their normal
state. In other words, the switches are set to their initial position,
the valves switch to their normal position, the cylinder pistons are
set to the position previously set for them, and all calculated quan-
tity values are deleted. Components used to adjust or harmonize
the system on the other hand, such as flow control valves, pres-
sure-reducing valves or potentiometers, retain the values set by the
user during the simulation.

By clicking (alternatively: Execute Pause ) you can switch


from Edit Mode to Simulation Mode without starting the simulation.
This is useful if you want to switch any components before starting
a simulation (e.g. to simulate a protection circuit where two switch-
es need to be pressed at the same time).

8.2 The different simulation modes

In addition to the functions for simulating circuits as presented in


the previous section ( , , ) there are also the following sup-
plementary functions:

Simulation reset and restart

Simulation in single step mode

Simulation up to a state change

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 93


8.2.1 Reset and restart of the simulation

With or Execute Reset , a running or paused simulation of a


circuit is reset and the circuit is returned to its initial state. The
simulation is then restarted immediately.

8.2.2 Single step mode

In single step mode, the simulation will stop after a small step.
More exactly, clicking or Execute Single Step starts the
simulation for a short period of time (about 0.01-0.1 seconds of
simulation time in the real system) before switching back into
pause mode ( ).

You can switch into single step mode directly from an actively
running simulation. This makes it easy to focus on key moments in
the simulation.

8.2.3 Simulation to a state change

Clicking or Execute Simulate until State Change causes the


simulation to start and run until a state change happens; the simu-
lation then pauses ( ). A state change happens when one of the
following takes place:

1. A cylinder piston moves against a stop

2. A valve switches over or is actuated

3. A relay switches over

4. A switch is actuated

94 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM


You can switch into state change mode directly from an actively
running simulation.

8.3 Simulating circuits you create yourself

This section assumes that you are already familiar with the basic
concepts involved in creating circuits. If necessary, read the section
Create a new circuit drawing" first.

Circuit diagrams can be created and modified in Edit Mode only.


You can identify Edit Mode by the mouse arrow pointer .

8.3.1 Example with a pneumatic circuit

Create the circuit shown in the figure.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 95


Figure 8/1: Simple pneumatic circuit

To define the valves actuation type, double click the valve. The
valves property dialog opens.

Go to the Configure Valve tab. Then, in the top drop-down


list on the left side, select a manual actuation with detenting.
On the right side, click the Spring-returned field.

If required, you can also set the standard nominal flow rate of the
valve.

Close the dialog box with &OK . As port 3 on the valve is only
needed as an air outlet, set a silencer there.

Double click the port.

96 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM


A dialog box opens where you can select a Terminator by clicking
the downward-pointing arrow to the right of the list and selecting
the blanking plug or a silencer symbol.

Select the third symbol (the simple silencer) and close the
dialog box.

The valve should now look like this:

Figure 8/2: Manually operated 3/2-way valve

Now try to simulate this circuit.

Start the simulation with (or with Execute Start or with


F9 ).

Move the mouse pointer onto the valve and click the valve with
the pointing finger .

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 97


Figure 8/3: Simulated circuit

Once the cylinder has advanced, the pressure in the cylinder supply
line must inevitably increase. This situation is detected by FluidSIM
and the parameters are recalculated; the pressure at the com-
pressed air supply increases to the set operating pressure.

Click the valve to make the cylinder retract.

In complex circuits, or for the transmission of high switching forces,


valves may also be activated indirectly. In the following we will
replace the direct manual activation of the valve with indirect
pneumatic activation.

Activate Edit Mode with (or with Execute Stop or with


F5 ).

98 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM


Select and delete the line that connects the cylinder and the
valve.

Drag another 3/n-way valve onto the drawing area and open
the valve configuration dialog box by double clicking (or by
Edit Properties... ). Construct a pneumatic valve (normally
closed), close the dialog box, put a silencer on port 3 again,
and arrange the components as follows:

Figure 8/4: Circuit with unconnected components

Connect the new valves outlet port to the cylinder.

Draw a line from the outlet port of the manually operated valve
to the control port of the pneumatic valve.

If necessary, drag the line segments until the drawing is ar-


ranged clearly.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 99


The circuit should now look something like this:

Figure 8/5: Circuit with indirect activation

Save this circuit with (or with File Save File ). FluidSIM
automatically opens the file selection box if the file did not al-
ready exist; you can enter a file name in that box.

Start the simulation with and click the manually operated


valve.

When you click a valve, the real behavior of the valve is simulated.
In our example, the clicked valve is switched over and recalculation
begins automatically. As a result, the indirectly activated pneumatic
valve is switched and the cylinder advances.

FluidSIM not only animates the switching of manually actuated


components, but nearly all components which have multiple states.

100 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
The following figure shows a 3/2-way valve in closed position and
in open position:

Figure 8/6: Closed and open 3/2-way valve

When non-detenting components are clicked, they remain actuated


as long as the mouse button is held down.

Stop the simulation and switch to Edit Mode. Select the state
diagram from the component library and move it into the circuit
window.

The state diagram records the quantity values for the most im-
portant components and displays them in graph form.

Move the state diagram to a free space in the circuit drawing


and drag and drop the cylinder onto the diagram.

A dialog box opens where you can select the quantity values you
are interested in. In this instance, only the position is of interest, so
you can remove the check marks for the other values (velocity,
acceleration).

Start the simulation and observe the diagram.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 101
Figure 8/7: Circuit with state diagram for the cylinder

Set the simulation to Pause and move the mouse pointer


onto the curve on the diagram.

If the mouse pointer rests on the diagram for a second, a box ap-
pears showing the exact values for time and the relevant quantity
value. If you move the mouse along the curve, the display alters
accordingly, updating the values as the mouse pointer moves.

102 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 8/8: Display of the exact values in the state diagram

You can use multiple state diagrams in one window, and can also
display multiple components in the same diagram. You can add a
component to a state diagram by dragging it onto the diagram. A
dialog will open, where you can select the quantity values to be
logged and can assign different colors to them. Dragging onto the
diagram again opens the dialog box again, allowing you to change
your selection. If no quantity value is assigned to a component, it is
not displayed in the diagram.

This concludes the example. Further editing and simulation con-


cepts are described in the next section.

8.3.2 Example with a hydraulic circuit

Create the circuit shown in the figure.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 103
Figure 8/9: Simple hydraulic circuit

To define the valves actuation type, double click the valve. valves
property dialog opens.

Go to the Configure Valve tab. Then, in the top drop-down


list on the left side, select a manual actuation and the valve
bodies Crosswise and Parallel. Then on the right side, click
the Spring-returned field.

If required, you can also set the hydraulic resistance of the valve.

Close the dialog box with &OK .

The valve should now look like this:

104 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 8/10: Manually operated 4/2-way valve

Now try to simulate this circuit.

Start the simulation with (or with Execute Start or with


F9 ).

Then all pressures and flow rates are calculated, the lines are
colored, and the cylinder advances:

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 105
Figure 8/11: Simulated circuit

Once the cylinder has advanced, the pressure in the cylinder supply
line should increase. This situation is detected by FluidSIM and the
parameters are recalculated; the pressure on the pump side in-
creases to the value predefined by the limit protection in the pump
unit.

To limit the pressure to a lower value, you have to safeguard the


pump unit with a pressure relief valve.

Activate Edit Mode with (or with Execute Stop or with


F5 ).

106 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Drag a pressure relief valve and a second tank onto the draw-
ing area.

If necessary, drag the line segments until the drawing is ar-


ranged clearly.

The circuit should now look something like this:

Figure 8/12: Circuit with pressure relief valve

Save this circuit with (or with File Save File ). FluidSIM
automatically opens the file selection box if the file did not al-
ready exist; you can enter a file name here.

Start the simulation with .

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 107
The cylinder advances. Once it reaches its stop, a new situation is
created. This situation is detected by FluidSIM and the parameters
are recalculated; the pressure relief valve opens, and the resulting
distribution of pressure is shown:

Figure 8/13: Circuit with open pressure relief valve

FluidSIM not only animates the switching of manually actuated


components, but nearly all components which have multiple states.

The following figure shows a pressure relief valve in closed position


and in open position:

108 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 8/14: Closed and open pressure relief valve

Remember that manually operated valves and switches can be


switched during Simulation Mode by clicking them with the mouse:

Move the mouse pointer onto the left-hand side of the direc-
tional control valve.

The mouse pointer changes into a hand with pointing finger


indicating that the valve can be switched over.

Click the left-hand side of the valve and hold down the mouse
button.

When you click a valve with the mouse, the real behavior of the
valve is simulated. In our example, the clicked valve is switched
over and recalculation begins automatically. As a result, the pres-
sure relief valve closes and the cylinder retracts. As soon as the
cylinder reaches its left-hand stop, the pressure relief valve opens
again.

When non-detenting components are clicked, they remain actuated


as long as the mouse button is held down.

Stop the simulation and switch to Edit Mode. Select the state
diagram from the component library and move it into the circuit
window.

The state diagram records the quantity values for the most im-
portant components and displays them in graph form.

Move the state diagram to a free space in the circuit drawing


and drag and drop the cylinder onto the diagram.

A dialog box opens where you can select the quantity values you
are interested in. In this instance, only the position is of interest, so

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 109
you can remove the check marks for the other values (velocity,
acceleration).

Start the simulation and observe the diagram.

Figure 8/15: Circuit with state diagram for the cylinder

Set the simulation to Pause and move the mouse pointer


onto the curve on the diagram.

If the mouse pointer rests on the diagram for a second, a box ap-
pears showing the exact values for time and the relevant quantity
value. If you move the mouse along the curve, the display alters
accordingly, updating the values as the mouse pointer moves.

110 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 8/16: Display of the exact values in the state diagram

You can use multiple state diagrams in one window, and can also
display multiple components in the same diagram. You can add a
component to a state diagram by dragging it onto the diagram. A
dialog will open, where you can select the quantity values to be
logged and can assign different colors to them. Dragging onto the
diagram again opens the dialog box again, allowing you to change
your selection. If no quantity value is assigned to a component, it is
not displayed in the diagram.

This concludes the example. Further editing and simulation con-


cepts are described in the next section.

8.3.3 Example with an electronic circuit

Create the circuit shown in the figure.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 111
Figure 8/17: Simple electronic circuit

Now try to simulate this circuit.

Start the simulation with (or with Execute Start or with


F9 ).

Then all voltages and currents are calculated, and the potential
from the positive terminal of the electrical power source to the
pushbutton is colored.

Click the pushbutton and hold down the mouse button.

The current now flows through the pushbutton to the ground via
the ammeter and the light:

112 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 8/18: Simulated circuit

The values for current and voltage can be read on the measuring
devices. So far, the circuit is a purely electric circuit, strictly speak-
ing. Now lets add an electronic component: the diode.

Stop the simulation and switch to Edit Mode. Modify the circuit
as shown in the figure and start the simulation.

Ensure that the diode is installed as shown. When you actuate the
pushbutton, you will see that the potential only reaches as far as
the diode:

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 113
Figure 8/19: Diode installed in reverse direction

Remove the diode and install it the other way around.

In this case rotating or mirroring the diode is not enough because


while that would turn the component around, it would not change
the line connections. That means that the lines would run through
the component and the drawing would look correct.

FluidSIM detects drawing errors of this kind, highlights the critical


sections, and issues a warning:

114 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 8/20: Warning of error in line layout

Once the diode is installed correctly, the current will flow through
the diode and the light will light up:

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 115
Figure 8/21: Diode installed in forward direction

In practice it is important in electronics to pay attention to the exact


currents and voltages. Electronic components are very sensitive
and can be destroyed quickly if subjected to excessive loads.

Next, the pushbutton will be replaced by a potentiometer.

Stop the simulation and switch to Edit Mode. Modify the circuit
as shown.

116 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 8/22: Simple circuit with a potentiometer

The potentiometer allows the resistance to be modified using a


rotating or sliding controller. In FluidSIM you can click the potenti-
ometer during the simulation and modify the resistance value as
with a real potentiometer.

Start the simulation and display the amperages using View


Quantity Values... . Alternatively, you can also press the I key
repeatedly. Now click the potentiometer and watch how the
current flow changes.

Stop the simulation and switch to Edit Mode. Select the state
diagram from the component library and move it into the circuit
window.

The state diagram records the quantity values for the most im-
portant components and displays them in graph form.

Move the state diagram to a free space in the circuit drawing


and drag and drop the ammeter onto the diagram.

A dialog box opens where you can select the quantity values you
are interested in. In this instance, only the amperage is of interest.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 117
Start the simulation, vary the resistance value of the potenti-
ometer, and observe the diagram.

Figure 8/23: Circuit with state diagram for the ammeter

Set the simulation to Pause and move the mouse pointer


onto the curve on the diagram.

If you move the mouse along the curve, the display alters accord-
ingly, updating the values as the mouse pointer moves. If you move

118 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
the mouse along the curve, the display alters accordingly, updating
the values as the mouse pointer moves.

Figure 8/24: Display of the exact values in the state diagram

You can use multiple state diagrams in one window, and can also
display multiple components in the same diagram. You can add a
component to a state diagram by dragging it onto the diagram. A
dialog will open, where you can select the quantity values to be
logged and can assign different colors to them. Dragging onto the
diagram again opens the dialog box again, allowing you to change
your selection. If no quantity value is assigned to a component, it is
not displayed in the diagram.

This concludes the example. Further editing and simulation con-


cepts are described in the next section.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 119
Advanced concepts in simulating and creating circuits

Chapter 9
9. Advanced concepts in simulating and creating circuits

This section describes advanced concepts and functions for simula-


tion and circuit creation in FluidSIM.

9.1 Adjusting the component parameters

Most of the symbols in FluidSIMs component library are basic


symbols representing various different versions of a component.
You can use the properties dialog box to customize the compo-
nents parameters, size, characteristic curves etc..

In Expert Mode there are sometimes many more parameters


available, depending on the component. These allow you to modify,
for example, spring forces, friction, or effective area. These parame-
ters are hidden in the standard mode. To avoid having to switch
Expert Mode on and off continuously, you can use the Show all
settings option to temporarily display all parameters or to hide the
advanced settings.

Drag a one-way flow control valve (throttle check valve) onto


the drawing area and open the properties dialog box by double
clicking.

You can access the adjustable parameters on the Component


Parameters tab.

120 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 9/1: Adjustable parameters of the one-way flow control
valve

Show designation Shows the designations of the parameters displayed using the
Display option.

Show variable Shows the variables of the parameters displayed using the Display
option.

Show Unit Shows the units of measurement of the parameters displayed using
the Display option.

Display Check this box if you want that parameter to be displayed in the
circuit.

Variable Clicking this button takes you to a dialog box with assignment
options for accessing the parameter in GRAFCETs or for controlling
it with a game controller.

In the Opening level row, click the button for variable assign-
ment.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 121
Figure 9/2: Variable and controller assignment of a parameter

Predefined variable This is the standard, complete variable name. It is made up of the
identification entered by you and the internal parameter name. You
can use this variable name to access the parameter in GRAFCETs in
order to query it or modify its value.

User-defined alias If you do not like the predefined variable name, you can enter your
own name for it here. Note that this alias has to be unique across
the entire page or project. FluidSIM issues a warning if an alias
name is entered twice.

122 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Controller assignment As described in the "Adjusting component parameters during the
simulation" section, many component parameters can be altered
with the mouse during the simulation. FluidSIM also offers the
option of controlling parameters via connected game controllers
(e.g. Microsoft Xbox controller). This is especially practical when
you need to modify several parameters at the same time during a
simulation.

Axis Here you can define which axis you want to use to control the
parameter during the simulation. To assign an axis, simply click in
the field and briefly actuate the desired controller axis. FluidSIM
then enters the desired axis.

Dead-zone This value determines how much movement of the controller axis is
required to trigger a signal. This prevents unintended modification
of values from very small movements of the fingers.

Range Sometimes you may wish to use the game controller to control only
a certain range. This can be necessary above all because the con-
trol levers on most controllers spring back to their zero position
automatically as soon as they are released. Using the mouse to-
gether with the straight line on the graph, you can interactively
determine how the controller position relates to the parameter.

Controller assignment is not available for the simulation variables


calculated by FluidSIM (piston positions, velocities, pressures, flow
rates, etc.) because these variables only permit read access. Simi-
larly, these variables cannot be assigned in GRAFCETs. FluidSIM
displays a warning if an attempt is made to modify a simulation
variable.

Simulation variables therefore have only the option of variable


assignment.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 123
Figure 9/3: Variable assignment of a simulation parameter

9.2 Special settings for cylinders

To adapt a cylinder, drag a representative cylinder into the circuit


and open the properties dialog box. It contains settings that you
can use to determine the appearance and function of the compo-
nent. See section "Configure cylinders" for the basic functions for
configuring the cylinder properties.

9.2.1 Cylinder friction and cylinder mass

If the options Show all settings and Enter manually are select-
ed, you can specify parameters defining a velocity-dependent
characteristic curve and the mass moved by the cylinder. If you
select Calculate automatically, an heuristic is applied which
calculates the settings on the basis of the cylinder dimensions.

Clicking an input field in the Cylinder friction section activates a


... button that can be used to open a dialog box containing a
graph displaying the cylinder friction as a function of the cylinder
velocity.

124 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 9/4: Friction curve of a pneumatic cylinder

9.2.2 External load and friction

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 125
Figure 9/5: External load on the cylinder

Moving mass Enter here the mass of the load that you want the cylinder to move.
The mass of the cylinder piston and piston rod is calculated auto-
matically by FluidSIM from the entered cylinder dimensions, so the
mass entered here refers only to the external load. In particular, an
entry of 0 does not mean that the moving parts in the cylinder
have no mass.

Friction The static friction and sliding friction define the friction of the
moving load on a surface. The internal friction in the cylinder is
calculated automatically by FluidSIM from the entered cylinder
dimensions. If the load is lifted or pulled without coming into con-

126 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
tact with a surface, enter 0 for both values. In practice it is very
difficult to arrive at reliable values for friction. FluidSIM therefore
offers set friction coefficients for some combinations of materials,
to provide a rough guide. If you compare other tables of friction
values, you will notice that the specifications (usually measured in
experiments) vary greatly from table to table. You should therefore
be cautious when interpreting the results of simulations influenced
by friction. Nonetheless, varying the friction values does allow you
to see clearly the physical effects of static and sliding friction. Note
also that the mounting angle influences the friction force from the
moved load. You can adjust the mounting angle on the Component
Parameters tab.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 127
9.2.3 Force profile

Figure 9/6: Force profile of the cylinder

Constant force If you want a constant force to be applied over the entire range of
cylinder movement, select this option and enter a force.

Apply force profile Select this option if you want the force to change depending on the
cylinders position. By clicking the mouse in the graph field, you
can interactively set reference points which will be interpolated to
form a line. Alternatively, you can select an existing reference point

128 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
and numerically enter the two values in the input fields for the
piston position and the corresponding force.

You can use the sliders to adjust the displayed value ranges for
position and force. As the force on the y-axis covers an especially
wide numerical range, it is advisable to start by restricting that
interval so that the shape of the curve can be seen clearly.

Retraction = Extraction Select this option if you want to apply the same force profile for
advancing and retraction. Otherwise, remove the checkmark and
enter separate force profiles on the tabs Extraction and Retrac-
tion.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 129
9.2.4 Actuating labels

Figure 9/7: Actuating labels on the cylinder

Here you can create new actuating labels or modify existing ones.
This dialog box is identical to the one that opens when you double
click an distance rule.

Displacement encoder In addition to the actuating labels you can also enter a special label
for a continuous displacement encoder or select from the list of
counterparts already present in the project.

130 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
9.3 Special settings for directional control valves

To adapt a directional control valve, drag a representative cylinder


into the circuit and open the properties dialog box. It contains
settings that you can use to determine the appearance and function
of the component. See section "Configure a way valve" for the
basic functions for configuring the valve properties.

9.3.1 Hydraulic resistance

For hydraulic valves, you can adjust the hydraulic resistance. In


practice the hydraulic resistance is often given by a curve or a pair
of values (pressure drop/flow rate). In the field Hydraulic re-
sistance you can either enter a specific value or alternatively click
the ... button. That takes you to a dialog box where you can
define the parabola either by interactively clicking in the graph field
or by entering a pair of values.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 131
Figure 9/8: Hydraulic resistance curve

9.4 Additional simulation functions

This section describes additional functions for the simulation of


circuit diagrams.

132 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
9.4.1 Simultaneous actuation of several components

So that you can actuate multiple pushbuttons or spring-returned


valves at the same time, you can put them in a permanently actuat-
ed state. You can permanently actuate a pushbutton (or valve with
manual actuation) by clicking it with the mouse while pressing the
Shift key. You can release this permanent actuation by clicking
once on the component.

Sometimes it may be necessary for multiple actuated objects to be


released at the same time. In that case, when clicking the object,
hold down the Ctrl key instead of the Shift key. The switched
components then remain in the actuated state until you release the
Ctrl key again, at which time all the objects actuated in this way
return to their initial position simultaneously.

For more complex switching operations or continuous adjustments,


we recommend using a game controller. For more details, see
"Adjusting the component parameters".

9.4.2 Simulation of individual pages and entire projects

In FluidSIM it is possible for multiple circuits to be open at the same


time. Circuits whose pages belong to a project are simulated as an
entire system. This is practical if, for example, you want to create
the hydraulic or pneumatic part and the electrical part on separate
pages. You can also divide large drawings across multiple pages
and define the line connections using interruption points. When a
circuit belonging to a project is simulated, all the other pages of the
project switch into Simulation Mode as well when the simulation is
started. While the simulation is running, it is therefore not possible
to edit any pages belonging to the open project.

In contrast, if pages that do not belong to the project are edited or


simulated, the editing or simulation always applies only to the

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 133
currently active circuit window. In such cases, it is therefore possi-
ble to simulate one circuit while editing another.

9.5 Displaying quantity values

The numerical values for all or some quantity values in a circuit can
be displayed even without measuring devices.

In the View menu, click Quantity Values... to open the


dialog box for the display of quantity values:

134 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 9/9: Dialog box for adjusting the quantity values display

Here you can define how every quantity value listed (Velocity,
Pressure, etc.) will be displayed.

For the display of pressure values, flow rates, and forces, you can
choose between different units of measurement. These settings
take effect when quantity values are displayed at connectors and
components and on state diagrams.

None Do not display any values for this quantity value.

Individual Display values only at connection points previously selected by the


user.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 135
All Display all values for this quantity value.

Display measurement units Activate this option if you also want the unit of measurement to be
displayed for the quantity values.

You can use the key in the Shortcut column to switch between
the display types None , Individual and All for that
particular quantity value without having to open the dialog box.

Proceed as follows to select connection points for the display of


individual quantity values:

Open a circuit.

In Edit Mode, double click a component connector, or select


the menu item Edit Properties... .

The dialog box for the connectors settings then opens. In the
Display quantity values field, you can choose which quantity
values are to be displayed at that connector when the Individual
option is activated for that parameter in the dialog box for quanti-
ty values display.

9.5.1 Display of direction of quantity values in FluidSIM

Vectorial quantity values are characterized by their quantity and


their direction. In circuit diagrams, the direction is displayed at the
component connectors by a mathematical sign (+ = into a com-
ponent, = out of a component). If the amount of the quantity
value is close to zero, the exact numerical value is not displayed.
Instead, > 0 is displayed for a small positive value and < 0 for a
small negative value.

In the case of fluidic flows, the direction is also indicated by an


arrow in the middle of the line segment. The visual impression is
reinforced by conveyor-belt-style animation of the lines.

136 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
9.6 Displaying state diagrams

The state diagram records the quantity values for the most im-
portant components and displays them in graph form. Quantity
values or output variables all those values calculated by FluidSIM
during the simulation or set by the user, such as: position, velocity,
acceleration, force, switching position, pressure, flow rate, opening
level, revolutions/rpm, voltage, current, digital state, etc.

You can use multiple state diagrams in one window, and can also
display multiple components in the same diagram. You can add a
component to a state diagram by dragging it onto the diagram. A
selection dialog box will open, where you can select the quantity
values to be logged and can assign different colors to them. Drag-
ging onto the diagram again opens the dialog box again, allowing
you to change your selection.

In Edit Mode, double click a state diagram, or select the menu


item Edit Properties... .

The following dialog box will open:

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 137
Figure 9/10: Dialog box for the state diagram

Display interval Here you can enter the start and end times of the interval during
which you want the quantity values to be logged. You do not nec-
essarily need to know before starting the simulation the times at
which the important events will occur; you can always change the
display interval as desired after the simulation because FluidSIM
always logs all values internally for the entire simulation period. If
you select the Adjust automatically field, the entered limits are
ignored and the time axis is scaled so that the entire simulation
time is displayed. Activate the Scroll automatically field if you
want the diagram to display the last n seconds. In this case, the
time axis will be displaced toward the left-hand side once the
simulation period exceeds the defined time window. In the input
field, you can specify the number of seconds to be displayed in the
time window.

Diagram columns Here you can select which columns you want to be displayed at the
left-hand side of the diagram. You can choose the columns De-
scription, Identification, and Quantity value in any combina-
tion.

138 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Log file If you wish, FluidSIM can create a log file of the quantity values.
Activate this option by entering the full path for the file in the input
field and select a suitable time increment. Please note that entering
very small increments may result in a very large volume of data.
You may need to reduce the simulation time or increase the time
increment.

Color Defines the color of the diagram.

Fill Area Defines whether the entire area is filled with the chosen color or
just the border of the diagram.

Layer In this drop-down list, you define the Layer of the diagram. You can
set the Layer by clicking the downward-pointing arrow to the right
of the list and selecting a layer. Depending on the setting for draw-
ing layers, the rectangle might not be displayed or might not be
able to be edited. In order to see the object or change its settings,
you have to temporarily activate the drawing layers with menu item
View Drawing Layers... .

Quantity values This list contains all the quantity values displayed in the diagram.
Every component is listed together with its identification, and all its
output variables are listed below it. Every variable can be selected
and deselected with a checkmark. Once you have marked a varia-
ble, you can use the buttons at lower right to define the color, line
style, and line thickness for it. You can use Add to select the
components you want. Delete deletes the marked component
together with its quantity values, and Find Target... takes you to
the relevant component in the circuit.

9.7 Coupling hydraulics, pneumatics, electrics and mechanics

All three available technology versions, FluidSIM-P, FluidSIM-H and


FluidSIM-E, allow you to create basic electrical circuits. In the
pneumatics and hydraulics versions, they are used primarily to
control the fluidic components. Because these simple electrical
components are simulated completely with full physical accuracy,
just as much as the electronic components are, they can be used

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 139
and interchanged across all FluidSIM versions and can be combined
with the electronic components in FluidSIM-E.

The following figure shows a small example:

Figure 9/11: Simple electrical circuit

Create this circuit on your computer.

Start the simulation and observe that the indicator light lights
up.

There are electrical components that link electrical circuits with


pneumatic or hydraulic circuits. These include switches that are
operated pneumatically or hydraulically, and solenoids for the
control of valves.

As the electrical circuit is drawn separately from the fluidic circuit,


you need a way of creating a definite link between electrical com-
ponents (e.g. a valve solenoid) and fluidic components (e.g. a
certain valve position). One way of doing this is with so-called
labels.

140 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
A label has a specific name and can be assigned to a component. If
two components have labels with the same name, they are con-
nected even if there is no visible line drawn between them.

You can enter the name for a label in a dialog box which you open
either by double clicking the component or by selecting the compo-
nent and clicking Edit Properties... . With electrically operated
valves (solenoid actuated), the labels are entered on the left and
the right by double clicking the appropriate connector, as op-
posed to clicking in the middle of the component.

The following example illustrates how labels are used in FluidSIM.

Activate Edit Mode with or with Execute Stop .

Expand the circuit as shown in the following figure:

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 141
Figure 9/12: Simple electro-pneumatic circuit

So that the valve can be controlled by the solenoid, these compo-


nents need to be linked using labels.

Double click the valve solenoid or select the solenoid and click
Edit Properties... .

The following dialog box appears:

142 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 9/13: Dialog box for the valve solenoid

Identification This text field is for entering a label name. A label name can be up
to 32 characters long and can contain numerals and special charac-
ters as well as letters.

Enter a name (e.g. Y1) for this label.

Double click the outside of the solenoid on the valve to open


the dialog box for the label name.

Enter the same label name there as for the solenoid (Y1).

The solenoid is now connected to the valve.

In reality, the valve solenoid would not be activated directly via the
switch but via an intermediate relay. This is left out here for the
sake of simplicity.

Start the simulation.

The electrical current and the pressure and flow distribution are
calculated, and the resulting pressures are shown in color.

If you want to view the exact values for the quantity values, you can
activate them in the dialog box accessible via View Quantity
Values... . The activated quantity values are shown at the compo-
nent connection points. For more detailed information about this,
see "Displaying quantity values".

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 143
Operate the electrical switch.

The valve then switches over and the cylinder advances:

Figure 9/14: Simulation of the electro-pneumatic circuit

In addition to manual actuation or electrical control, some valves


can also be switched over mechanically by the piston rod of a
cylinder or by a permanent magnet on the piston. Mechanical
linkages like this are created in the same way as those with electri-
cal components: The connection is established by applying a label
to the cylinders distance rule and another to the mechanical con-
nector on the valve.

Drag a configurable valve into a circuit window and specify a


mechanical actuation (e.g. the stem).

144 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 9/15: Valve with mechanical actuation

Double click the end of the stem.

A dialog box will open in which you can enter a label. If you enter
the same label on the cylinders distance rule, the valve will be
actuated mechanically when the cylinders piston rod reaches the
specified position.

A special instance of this type of linkage is the connection of a


cylinder to a displacement encoder. You can use such connections
to construct closed-loop control systems in combination with
proportional valves, for example. Further information about propor-
tional control systems can be found in section "Open-loop and
closed-loop control by using continuous valves".

Double click a cylinder.

A dialog box will open in which you can adjust the cylinders prop-
erties. Go to the Actuating labels tab.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 145
Figure 9/16: Cylinder configuration dialog box

Enter a label under Displacement encoder.

Add the displacement encoder from the component library to


the circuit and double click to open the properties dialog box.
Enter the same label there as you entered for the cylinder.

146 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 9/17: Linking the displacement encoder to the cylinder

The displacement encoder returns a voltage at its output which is


proportional to the piston position of the linked cylinder. When the
cylinder is fully retracted, this voltage will be the set minimum;
when the cylinder is fully advanced, it will be set maximum.

9.7.1 Display styles for labels

As with component designations, it is often desirable to surround


labels with a rectangular frame. You can select this in the basic
settings for fluidic and electrical labels in the Options... menu.
However, you can also set the frame for specific texts to be differ-
ent from the standard frame. To do so, double click the specific
text:

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 147
Figure 9/18: Dialog box for setting the text frame

Under Text Attributes you can set the option Frame Text.

FluidSIM automatically positions the labels so that they appear at


an appropriate position near the component or connector. Howev-
er, you can also move the labels using the mouse or the keyboard.
To do so, click the label and drag it to the desired position. To
modify the position with the keyboard, select the label (or the
associated connector) and move the label using the cursor keys.

If you have inadvertently moved a label text so far that you cannot
tell which component it belongs to, you can double click the label
to open the properties dialog box and then activate the associated
component with Find Target... .

9.8 Operating switches

This section describes how switches can be actuated by cylinders,


relays, pressure, or by other switches.

148 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
9.8.1 Switches at cylinders

Limit switches, proximity switches, and mechanically actuated


valves can be activated by the piston of the cylinder. To make this
possible, first you have to place a distance rule on the cylinder so
that the switches can be positioned.

Drag the cylinder onto the drawing area and open its proper-
ties by double clicking. Go to the Actuating labels tab and en-
ter a label along with the start and end positions.

When you close the dialog box, the distance rule will appear auto-
matically above the cylinder. You can move or copy the distance
rule from one cylinder to another. When the distance rule comes
close to a cylinder, it slots automatically into the correct position.

The correct position for a distance rule depends on the cylinder


type. Distance rules can be positioned over the cylinder housing, in
front of the cylinder housing (next to the advanced piston rod) or in
both positions at the same time:

Figure 9/19: Examples of distance rule positions

To modify the labels or positions or to add more, you can either


open the properties for the associated cylinder or enter these
details directly on the distance rule.

Double click the distance rule.

The following dialog box appears:

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 149
Figure 9/20: Dialog box for the distance rule

Label The text fields in the left-hand column are used to enter the label
names of proximity switches or limit switches in the electrical
circuit that you want the cylinder piston to actuate.

Position The text fields in the right-hand columns define the exact start and
end positions of the switches on the cylinder.

Enter Y1 as the label in the first row and enter 35 for both
the start and end positions, and close the dialog box by clicking
&OK .

A dash with the label name will appear immediately at the corre-
sponding position under the distance rule:

Figure 9/21: Cylinder with distance rule

This means that this cylinder will activate the switch or valve la-
beled Y1 once its piston has moved 35 mm, assuming that the
same label was entered on the switch in the electrical part of the
circuit or on the mechanical connector of the valve.

150 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Once the cylinder in the above example passes the 35 mm position,
the switch will drop out again. If you want the actuation to be
maintained over a longer distance, enter the start and end posi-
tions accordingly in the dialog box.

To place labels on electrical switches, double click the component.


Valves with mechanical actuation have a special connector for this
purpose, which may be on the end of the stem or in the center of
the roller, for example. If there is already a label on the component
or connector, you can also double click the label directly and then
click Find Target... to open the corresponding dialog box for
editing the label.

9.8.2 Relays

A relay or solenoid can be used to actuate multiple switches or


contacts simultaneously. It is of course necessary to link the relay
to the relevant switches. Therefore in FluidSIM, relays too have
labels, which can be used to define an association with switches in
the usual way. When you double click a relay, the dialog box for the
label name will open.

The following figure shows an electrical circuit diagram in which a


relay simultaneously actuates two break switches and two make
switches:

Figure 9/22: Relay with linked switches

In addition to the simple relay, there are also relays with switch-on
delay, relays with switch-off delay, and counting relays. They en-
sure that the linked switches are not actuated until a defined time
or number of pulses is reached. With these relays too, double
clicking will open the corresponding dialog boxes for entering the
values.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 151
9.8.3 Coupling mechanical switches

The mechanical linkage of mechanical (manually operated) switch-


es is accomplished in FluidSIM by assigning a label. If multiple
mechanical switches have the same label, actuating one of them
will cause all the identically labeled switches to be actuated with it.

9.8.4 Automatic switch altering

FluidSIM identifies delay switches, limit switches, and pressure


switches by their method of installation and by their labels and
automatically adds the corresponding symbol to the switch in the
electrical circuit: for switch-on delayed, for off-delayed, for
mechanical actuated switches and for pressure switches. In the
case of switches actuated by the cylinder piston, you can choose
how they are displayed in the properties dialog box for the closer,
opener, and changeover:

152 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 9/23: Dialog box for general electrical switches

This means that special symbols do not need to be used for these
switches in FluidSIM. The simple switch symbols can be used
instead:

Figure 9/24: Simple switch symbols

9.9 Adjusting component parameters during the simulation

Most components have parameters that can be adjusted in Edit


Mode. Some of these components have already been discussed in
earlier sections.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 153
You can open the dialog box for adjusting the parameters by dou-
ble clicking or with Edit Properties... .

Several components can be adjusted during the simulation in the


same way as they would be in reality. For example, the operating
pressure of the compressed air supply, the delivery rate of the
pump, the opening level of the throttle valve, or the resistance of
the potentiometer can be altered continuously. To do this, you do
not need to open the properties dialog box and then close it with
&OK ; all you need to do is click once on the component to open a
window with sliders. Your changes take effect on the simulation
immediately. As soon as you click another component or an empty
space in the window, the dialog window with the sliders disappears
automatically.

In Simulation Mode, when you move the mouse over a component


that allows such real-time adjustments, the mouse pointer changes
into the slider symbol .

Figure 9/25: Adjusting the opening level during the simulation

For precision adjustment, some sliders allow you to select the


control range. However, you can also enter the numeric value
directly as a number in the input field.

Most parameters can also be controlled using a game controller.


For details, see "Adjusting the component parameters".

154 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
9.10 Settings for simulation

In the Options... menu, basic parameters and options for the


simulation can be set under Simulation, Environment parameters,
Fluid properties, and Sound.

Note that these settings are only used if no others are defined in
the page or project properties. Newly created pages and projects
are preset with the standard values set under Options... .

9.11 Use of the EasyPort-hardware

FluidSIM can directly address EasyPorts connected to the serial


ports of the PC. No additional drivers or auxiliary programs are
required. These days, however, serial ports are rare outside indus-
trial environments. To use the EasyPort via a USB cable, you may
require drivers that you will find on the installation DVD and which
you can also download online from Festo Didactic GmbH & Co. KG.

The EasyPort hardware is linked to the components in FluidSIM via


special electrical input/output components, which each have either
eight digital inputs/outputs or two analog outputs/four analog
inputs.

The EasyPort hardware can also be addressed using DDE and OPC
communication. This allows you to control even remote EasyPort
modules that are not connected locally (e.g. via a network connec-
tion). However, if the EasyPort modules are connected directly to
the simulating PC, it is recommended to set up the direct connec-
tion.

Drag a digital input or output component from the component


library into a circuit window and open the properties dialog box
by double clicking or via the menu item Edit Properties... .

The following dialog box will open:

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 155
Figure 9/26: Dialog box for the EasyPort components

Direct EasyPort connection Here you can set the serial port by which the hardware is connected
to the PC, which EasyPort module and port number is assigned to
the input/output component. If you do not know the exact number
of the serial port, leave the setting as Automatically. FluidSIM
then searches all COM ports for connected EasyPorts.

Older EasyPorts are fitted as standard with only a serial port, of the
kind used for many years on PCs and also in industrial applications.
Modern PCs and especially portable computers, however, increas-
ingly do not feature this connection. Nonetheless the serial port
interface can be retrofitted easily using an inexpensive USB-to-
serial converter, allowing the EasyPort to be connected and operat-
ed anyway. The converters software does this by setting up a
virtual COM port, which is assigned a number higher than the
physically existing ports (usually COM 5). The hardware can be
addressed in the usual way via this virtual port.

Connector color Defines the color of the connection indicators for the input/output
component when the EasyPort connection is active and when the
connection is not present or is disrupted.

Voltage range With the analog interface components, you can select the voltage
range. This can be either from 0V to 10V or from -10V to 10V.

156 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
If FluidSIM does not find any EasyPort hardware at the start of the
simulation, a corresponding warning is issued. You can start the
simulation anyway, but if you do so FluidSIM will not make any
further attempts to find EasyPorts until the simulation is closed and
restarted. If, on the other hand, the connection is terminated while
the simulation is running (e.g. by inadvertently pulling out the
connecting cable), the simulation will continue to run without the
EasyPort link, but FluidSIM will attempt to restore the connection.
As soon as the hardware is once again available at the set port, the
connection is restored and the simulation continues with EasyPort
communication.

9.12 OPC and DDE communication with other applications

FluidSIM is capable of exchanging data with other applications,


allowing it to work together with a PLC, for example. A prerequisite
for this link is that the other application has an OPC interface or a
DDE interface. The link is established using the same interface
components as for the use of FluidSIM with the EasyPort.

Drag an input or output component from the component


library into a circuit window and open the properties dialog box
by double clicking or via the menu item Edit Properties... .

The following dialog box will open:

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 157
Figure 9/27: Dialog box for the OPC components

In the Connect EasyPort via list, select the OPC connection


option.

OPC server Enter the OPC server here or press the Pick... button and select it
from the list.

Item Enter the data item here or press the Pick... button and select it
from the list.

In order to establish communication via a DDE interface, first en-


sure that the DDE interface is active. You can do this with the global
option under DDE Connection.

In the Connect EasyPort via list, select the DDE connection


option.

158 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 9/28: Dialog box for the DDE components

Server This is the server name that FluidSIM uses when it registers in the
system as a DDE server. As the server name is a global setting, it
cannot be changed directly in this dialog box. Pressing the Global
DDE server name... button takes you to the options dialog box
where you can change the server name for the entire system.

Topic Here, enter the topic via which you would like to address the
components.

Label Here, enter the label or the item via which you would like to
address the components.

9.13 Open-loop and closed-loop control by using continuous


valves

In addition to simple directional control valves, which only have


discrete switching positions, FluidSIM also offers some continuous
valves. These are characterized by their ability to adopt a continu-
ous range of intermediate positions. Like electrically actuated

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 159
directional control valves, these components are controlled via a
proportional amplifier or via a valve solenoid. These valves, howev-
er, are represented by special symbols:

Figure 9/29: Proportional valve solenoid and amplifier

The separate proportional valve solenoid is used for position-


controlled continuous valves where the control and amplifier com-
ponent is built into the valve.

If you inadvertently use a label to link a directional control valve to


a proportional valve solenoid, or a proportional valve to a simple
valve solenoid, FluidSIM issues a warning.

The following two sections provide a brief introduction to the


options for open-loop control and closed-loop control with
FluidSIM.

The term open-loop control means that an output variable


changes as a function of an input variable. In this specific case, the
voltage on the proportional valve solenoid or amplifier represents
an input variable. The valve piston of the proportional valve is
shifted in a particular direction to a greater or lesser distance as a
function of the value (and the direction) of the electrical current
caused by that voltage (by means of an amplifier). This piston
displacement is the output variable. If the pressure at the valve
port is constant, the flow rate can be controlled in this way. If, on
the other hand, the flow rate is constant, the pressure drop will
change as a function of the opening level, determined by the valve
position.

The term closed-loop control is used when the output variable (or
a quantity value affected by it) is used in turn as the input variable.
It is also quite possible for multiple output variables (and quantity
values dependent on them) to be combined together with addition-
al input variables, using a calculation rule. A classic example is
position control, where a cylinder needs to move to a certain posi-

160 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
tion. The valve is activated electrically so that the cylinder moves.
The cylinders position (resulting from the movement caused by the
valve setting) is used in turn as an input variable, to determine the
deviation between the cylinders position and its setpoint position.
Once the cylinder has reached its target position, the deviation is 0
and the valve returns to its mid-position (closed position). The
cylinder thus comes to a halt. If inertia or external disruption caus-
es the cylinder to move past its target, the valve switches over to
the other side, reversing the flow direction, and the cylinder moves
back. This is the simplest form of closed-loop control, known as P
control (proportional control).

9.13.1 Open-loop control in pneumatics

In order to understand how the continuous components function,


please construct the following circuit (power supply, function
generator, voltmeter, proportional valve solenoid, regulating
valve):

Figure 9/30: Simple open-loop control of the regulating valve

Do not forget to fit silencers on the valves five pneumatic ports, in


order to prevent warnings from FluidSIM.

Start the simulation and observe the regulating valve.

The function generator generates a signal between 0 and 10 volts.


This varying voltage is converted by a proportional amplifier in the
valve into a corresponding current that actuates the proportional

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 161
valve solenoid, so that the valve connected to it is shifted to either
side to the maximum extent according to the signal voltage applied.

To switch over the valve to a lesser extent, the valve requires a


lesser maximum voltage. You can set that by opening the proper-
ties dialog box for the function generator, by double clicking.

Figure 9/31: Properties dialog box for the function generator

Enter 2 as the Amplitude, close the dialog box, and restart


the simulation.

The voltage will now vary between 3 and 7 volts. As a result, the
valve will still shift symmetrically, but with less displacement from
the mid-position.

Open the function generator properties again and set 3 as the


y offset.

The function generator now supplies a voltage between 1 and 5


volts, with the valve moving further to the left than to the right.

Open the function generator properties again and set Con-


stant as the signal type.

162 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
The sliders of the function generator for Frequency and Ampli-
tude have no function when the signal type is set to Constant.
This allows us to use it to simulate a manually adjustable potenti-
ometer.

Start the simulation and click the function generator (with a


single click).

A window opens showing the sliders of the function generator.

Figure 9/32: Adjusting the function generator during the simulation

Change the y offset very gradually, while observing how the


valve moves as a function of the slider setting.

9.13.2 Open-loop control in hydraulics

In order to understand how the continuous components function,


please construct the following circuit (power supply, function
generator, voltmeter, proportional valve solenoid, regulating
valve):

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 163
Figure 9/33: Simple open-loop control of the regulating valve

Do not forget to fit blanking plugs on the valves four hydraulic


ports, in order to prevent warnings from FluidSIM.

Start the simulation and observe the regulating valve.

The function generator generates a signal between -10 and 10


volts. This varying voltage is converted by a proportional amplifier
in the valve into a corresponding current that actuates the propor-
tional valve solenoid, so that the valve connected to it is shifted to
either side to the maximum extent according to the signal voltage
applied.

To switch over the valve to a lesser extent, the valve requires a


lesser maximum voltage. You can set that by opening the proper-
ties dialog box for the function generator by double clicking.

164 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 9/34: Properties dialog box for the function generator

Enter 4 as the Amplitude, close the dialog box, and restart


the simulation.

The voltage will now vary between -4 and 4 volts. As a result, the
valve will still shift symmetrically, but with less displacement from
the mid-position.

Open the function generator properties again and set 2 as the


y offset.

The function generator now supplies a voltage between -2 and 6


volts, with the valve moving further to the left than to the right.

Open the function generator properties again and set Con-


stant as the signal type.

The sliders of the function generator for Frequency and Ampli-


tude have no function when the signal type is set to Constant.
This allows us to use it to simulate a manually adjustable potenti-
ometer.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 165
Start the simulation and click the function generator (with a
single click).

A window opens showing the sliders of the function generator.

Figure 9/35: Adjusting the function generator during the simulation

Change the y offset very gradually, while observing how the


valve moves as a function of the slider setting.

9.13.3 Closed-loop control in pneumatics

Your task now is to set up a simple system of closed-loop position


control. To do so, modify the circuit as shown in the following
figure. Remember that you need to remove the silencers on the
valve ports before you can drag lines. Instead of the function gen-
erator, it is now the displacement encoder that supplies the input
voltage for the proportional valve solenoid. So you can apply the
label to the cylinder, open its properties dialog box, go to the
Configure Cylinder tab and set the Sensing option.

166 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 9/36: Simple closed-loop position control

Note that the regulating valve is mirrored horizontally in this exam-


ple.

Start the simulation and observe that the cylinder stops once it
has traveled half the distance.

Now we want to expand the circuit so that the cylinder can move to
any position we set on a slider during the simulation, as quickly as
possible but still accurately. This is done using a PID controller.

Construct the following circuit and set the parameter values for
the PID controller as shown.

Note that the regulating valve is mirrored from its position in the
example above.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 167
Figure 9/37: Position control with PID controller

Start the simulation and slowly move the y offset of the func-
tion generator between 0 and 10.

The cylinder moves until it reaches its setpoint position, where it


stops. The cylinders target position is proportional to the voltage
set on the function generator, with 0 V equating to fully retracted
and 10 V meaning fully advanced. The value 5 thus represents

168 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
the cylinder pistons mid-position. It does not matter what position
the cylinder starts from; it will always stop at the specified target
position.

Vary the initial piston position and observe how the cylinder
reaches its setpoint position every time without fail.

To study the closed-loop control procedure more closely, lets


examine the cylinders displacement and velocity up to its setpoint
position. You can do this by adding a state diagram, adjusting it to
a suitable size, and dragging the cylinder onto the diagram. A
dialog box will open where you should select the two quantity
values Position and Velocity.

Pneumatics are fast. So you can more clearly observe the effects
described below, set the stroke of the cylinder to 5000 mm.

Set the y offset of the function generator to 5 and the start


position of the cylinder to 0 and start the simulation.

The cylinder advances to the middle, losing velocity continuously


until it comes to a stop.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 169
Figure 9/38: Position displacement and change in velocity during
closed-loop control

It is often desirable for the cylinder to move at maximum velocity


until it reaches its setpoint position and then to stop as suddenly as
possible. You can do this by amplifying the position signal of the
displacement encoder, which will accelerate the switchover of the
regulating valve. This makes use of the fact that the PID controller
limits the output voltage for the proportional valve solenoid to 10
V.

Set the Proportional gain of the PID controller to 3 and start


the simulation.

170 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 9/39: Position displacement and change in velocity with
amplified input signal

You can see clearly that the cylinder now moves at a constant
velocity for a long distance. It then brakes sharply and comes finally
to a stop.

However, you can see that the cylinder piston moves clearly beyond
its target, due to its inertia and the compressibility of the air, and
moves back and forth several times before finally coming to rest.
These oscillations around the setpoint position are typical for this
kind of simple closed-loop control. In practice, you would try to
reduce these oscillations by tweaking the parameters of the PID or
loop controller. However, at this stage we will stop at the simple

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 171
basic principles, and refer you to the literature on proportional and
closed-loop systems for further reading.

9.13.4 Closed-loop control in hydraulics

Your task now is to set up a simple system of closed-loop position


control. To do so, modify the circuit as shown in the following
figure. Remember that you need to remove the blanking plugs on
the valve ports before you can drag lines. Instead of the function
generator, it is now the displacement encoder that supplies the
input voltage for the proportional valve solenoid. So you can apply
the label to the cylinder, open its properties dialog box, go to the
Configure Cylinder tab and set the Sensing option.

Figure 9/40: Simple closed-loop position control

Start the simulation and observe how the cylinder retracts and
the valve moves further and further into its closed position.

This makes the cylinder slower and slower until it is fully retracted.
Strictly speaking this is not really position control, because the
cylinder would have stopped when it reached its physical stop
anyway. So now lets change the relationship in the displacement
encoder between the piston position and the output voltage. For
example, if we want the cylinder to stop in the middle, the valve

172 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
must be in its closed position at the exact time when the cylinder
reaches that position. As the output voltage is proportional to the
piston position, it is easy to calculate how the voltages at the two
limits (cylinder retracted/cylinder advanced) need to be selected in
order for the voltage to be 0 V halfway through the cylinder stroke:

Figure 9/41: Adjusting the voltage limits for the displacement


encoder

Start the simulation and observe that the cylinder stops once it
has traveled half the distance.

Now we want to expand the circuit so that the cylinder can move to
any position we set on a slider during the simulation, as quickly as
possible but still accurately. This is done using a PID controller.

Construct the following circuit and set the parameter values for
the PID controller as shown.

Note that the pump unit and the tank are mirrored from their posi-
tions in the example above.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 173
Figure 9/42: Position control with PID controller

Start the simulation and slowly move the y offset of the func-
tion generator between -10 and 10.

The cylinder moves until it reaches its setpoint position, where it


stops. The cylinders target position is proportional to the voltage
set on the function generator, with -10 V equating to fully retract-

174 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
ed and 10 V meaning fully advanced. The value 0 thus repre-
sents the cylinder pistons mid-position. It does not matter what
position the cylinder starts from; it will always stop at the specified
target position.

Vary the initial piston position and observe how the cylinder
reaches its setpoint position every time without fail.

To study the closed-loop control procedure more closely, lets


examine the cylinders displacement and velocity up to its setpoint
position. You can do this by adding a state diagram, adjusting it to
a suitable size, and dragging the cylinder onto the diagram. A
dialog box will open where you should select the two quantity
values Position and Velocity.

Set the y offset of the function generator to 0 and the start


position of the cylinder to 0 and start the simulation.

The cylinder advances to the middle, losing velocity continuously


until it comes to a stop.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 175
Figure 9/43: Position displacement and change in velocity during
closed-loop control

It is often desirable for the cylinder to move at maximum velocity


until it reaches its setpoint position and then to stop as suddenly as
possible. You can do this by amplifying the position signal of the
displacement encoder, which will accelerate the switchover of the
regulating valve. This makes use of the fact that the PID controller
limits the output voltage for the proportional valve solenoid to 10
V.

176 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Set the Proportional gain of the PID controller to 10 and start
the simulation.

Figure 9/44: Position displacement and change in velocity with


amplified input signal

You can see clearly that the cylinder now moves at a constant
velocity for a long distance. It then brakes sharply and comes
quickly to a stop.

If the cylinder had to move a load, its inertia would cause it to move
slightly beyond its target and it would have to move back and forth

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 177
several times before coming to rest. These oscillations around the
setpoint position are typical for this kind of simple closed-loop
control. In practice, you would try to reduce these oscillations by
tweaking the parameters of the PID or loop controller. However, at
this stage we will stop at the simple basic principles, and refer you
to the literature on proportional and closed-loop systems for fur-
ther reading.

9.14 Use of the oscilloscope in electronics

For graphic display of the physical simulation variables, the state


diagram is available. However, for visual representation of high-
frequency and periodic signals, an oscilloscope is better. FluidSIM
has such an oscilloscope in its electronics library, which can be
installed in electrical circuits and connected like other measuring
devices (e.g. voltmeter und ammeter). Any number of oscilloscopes
can be installed and used at the same time.

Create a circuit comprising a function generator and an oscillo-


scope.

Figure 9/45: Simple circuit with function generator and oscillo-


scope

Set the function generator to the sine function and the fre-
quency to 1 kHz. Now start the simulation and click the oscillo-
scope.

A dialog window opens with a display modeled on a real oscillo-


scope.

178 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 9/46: Modeling of a real oscilloscope

Turn the various dials and observe how the displayed curve
changes.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 179
9.15 Simulation of rotating machines

A complete mathematical model and very accurate values for the


machines characteristic data are required in order to ensure cor-
rect physical simulation of a rotating electric machine. Characteris-
tic data include, for example, resistance and inductance of the
stator and rotor windings, the number of pole pairs and idling
speed without load.

However, these values are not included in the manufacturers


specifications or on the rating plates of common electric motors.
The values specified there describe the status of the motor at
nominal load. These usually include mechanical output power and
motor speed at a specified voltage, amperage and line frequency.

However, these data alone do not permit physically correct simula-


tion of an electric motor. The machines above mentioned inner
values are required.

And thus FluidSIM attempts to ascertain these required inner


values on the basis of the specified performance data in different
ways, especially in light of the fact that for some machines these
parameters are not easy to measure. And thus theres no need for
you, as a user, to get involved with the complicated internal layout
of a machine, and all you have to do is enter the machines perfor-
mance data, for example from the rating plate, after which the
machine can be simulated.

In the case of electric machines with a simple layout, above all DC


motors due to their engineering design, the characteristic data can
be readily derived from the performance data and directly calculat-
ed. Idling speed is additionally required in order to be able to
obtain unambiguous values.

But things are not that simple in the case of machines with more
complex designs such as asynchronous AC motors, capacitor mo-
tors and synchronous motors. Here its much more difficult to arrive
at the characteristic parameters on the basis of the machines
specified performance data. The physical relationships which are
taken advantage of in order to generate rotary motion in these

180 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
motors are so complex, that the machines inner values cannot be
calculated directly from the nominal values.

For this reason, FluidSIM attempts to ascertain the characteristic


data on the basis of various heuristic estimates and, to some ex-
tent, dynamic simulations, so that they are matched as well as
possible to the entered performance data. These calculations are
executed in the background after the machines parameters have
been entered or changed. When estimating the characteristic data,
FluidSIM always attempts to select data in such a way as to ensure
that the machines specified performance data are approached as
closely as possible, and that the machines specified performance
represents its maximum performance.

The fact that the inner values can only be approximated and not
precisely calculated results in the following effects in the simula-
tion:

Under certain circumstances it might not be possible to start


the simulation immediately.
After entering the parameters of a rotating electric machine, it
may take a moment before the simulation can be started. This
is because the machines characteristic data are calculated in
the background after the its parameters have been entered
(e.g. winding resistance). The simulation cannot be started un-
til these parameters have been determined. These data are al-
ways determined once only after parameter values have been
entered or changed. As long as the parameters are not
changed, theres no need to repeat the calculation.

Changed performance data in the simulation


FluidSIM always attempts to ascertain the characteristic pa-
rameters which best suit the attributes based on the entered
performance data. If you use the performance data of an actual
machine, this should usually work. But even if the entered per-
formance data do not correspond to an actual machine,
FluidSIM nevertheless attempts to find values for the charac-
teristic data so that a simulation can be run for the machine.
However, in this case some of the performance data in the sim-
ulation might not correspond with the entered data. Flow of
current through the machine, for example, serves as an addi-
tional degree of freedom for the calculation of the characteris-
tic data, which may deviate from the value in the simulation en-
tered by yourself. If FluidSIM doesnt find any appropriate pa-

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 181
rameters based on the user entries, a similar machine is calcu-
lated which corresponds at least to the most important attrib-
utes. If this works, the symbol is identified in gray in order to
indicate that not all of the entries have been used. The parame-
ters which could not be taken into consideration are displayed
in the components characteristics dialog box. The affected en-
try fields are identified there in color.

The simulation cannot be run with the selected parameters.


After entering the parameters, the characteristic data of the
electric machine are determined in the background. During this
process the program might discover that a given component
cannot be physically implemented with the entered data. In this
case the respective symbol is identified in the circuit diagram
and a corresponding error text is displayed. If this is the case,
check to make sure that you have entered all of the parameters
from the manufacturers specifications or the rating plate cor-
rectly. The parameters which might be incorrect are displayed
in the components characteristics dialog box. The affected en-
try fields are identified there in color.

The goal of the process run by FluidSIM is to provide you with a


correct physical simulation of electric machines without requiring
you to be precisely familiar with the details.

182 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
GRAFCET

Chapter 10
10. GRAFCET

This chapter provides an introduction to creating and simulating


GRAFCET plans with FluidSIM. See norm DIN EN 60848 for the
complete specification of the GRAFCET description language. Festo
Didactic provides a range of training documentation for more
detailed introductions to GRAFCET.

Unlike an SPS programming language, such as Sequential Function


Chart (SFC), GRAFCET is a graphic description language that de-
scribes the logical behavior and operation of a control system or a
process - regardless of the technical software and hardware imple-
mentation. FluidSIM can be used to both create and simulate
GRAFCET plans. The term GRAFCET is also used as a synonym for a
GRAFCET plan. It should be obvious from the context whether the
word GRAFCET refers to the plan or the language.

A GRAFCET essentially describes two aspects of a control system,


according to specified rules: the actions (commands) to be carried
out and the sequence of execution. The elementary components of
a GRAFCET are steps, actions and transitions and can be used in the
same way as pneumatic or electrical components. To achieve a
uniform operating concept, the GRAFCET elements feature connec-
tions that can be used to link them to each other (as with all other
FluidSIM components).

10.1 The various GRAFCET modes

FluidSIM accommodates various GRAFCET training aims by means


of three modes, which differ in terms of the degree of interaction
they provide between GRAFCET on the one hand and the pneumat-
ic, hydraulic, and/or electrical circuits on the other hand.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 183
10.1.1 Drawing only (GrafEdit)

The simplest mode, also referred to as GrafEdit in the following


sections, allows you to draw GRAFCET diagrams. Simulation or
animation of a GRAFCET is not possible in this mode. You can draw
a GRAFCET together with a fluidic or electrical circuit on one page or
on a separate page within a project. However, in this mode the
GRAFCET has no effect on circuit function, and the component
states are not transmitted to the GRAFCET. The GRAFCET is a draw-
ing only, with no action. This mode can be useful in practice in
order to prepare the draft circuit conceptually with a GRAFCET and
to verify it without the assistance of FluidSIM.

10.1.2 Observation (GrafView)

In this mode (also called GrafView), a GRAFCET can be drawn as


described above, but unlike the simple GrafEdit mode, the condi-
tions in GRAFCET objects can linked directly to variables in a corre-
sponding circuit (see section "Access to variables of circuit compo-
nents"). The GRAFCET can only have read access to the circuit
elements. The GRAFCET observes the circuit during the simulation
and is processed and visually presented according to the condi-
tions in transitions and actions.

This mode is practical for simple checking of whether the intended


function of the GRAFCET sequence matches the simulated system
characteristics. In this mode, the processing of the actions of the
GRAFCET has no effect on the other circuit elements. Control of the
circuit is therefore not possible.

10.1.3 Control (GrafControl)

The GrafControl mode expands the GrafView mode by not only


allowing read access to the fluidic and/or electrical circuit ele-

184 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
ments, but also permitting the GRAFCET actions to actively modify
the values of those elements. This means GRAFCET cannot only
take the place of an additional control, but can also initiate user
actions. For example, pressing a pushbutton or switching over a
manually operated valve can be simulated. This opens up a wide
range of control possibilities because the GRAFCET can query all
component parameters and also modify them when required. This
includes the initiation of switching operations, the adjustment of
flow control valves, and the modification of electrical resistances.

10.2 Setting the GRAFCET mode

Like the other simulation settings, the GRAFCET mode can be set for
a single page, for an entire project node, and also in the global
settings. For example, you can set the global GRAFCET settings
under Tools Options... , GRAFCET tab and you can set the page-
specific GRAFCET settings under Page Properties... , GRAFCET
tab.

So it is always clear which GRAFCET mode is active, FluidSIM in


Simulation Mode applies a colored border to pages containing a
GRAFCET. A gray frame shows that the GRAFCET is not simulated,
i.e. that GrafEdit mode is active. A blue frame indicates the
GrafView mode, in which the GRAFCET can read simulation parame-
ters. Finally, the red frame shows that the GRAFCET is in GrafControl
mode, meaning that it has both read and write access to the com-
ponent parameters.

10.3 GRAFCET elements

The following sections describe the individual elements offered by


FluidSIM to allow creation of GRAFCET plans that comply with the
GRAFCET standard.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 185
10.3.1 Steps

Steps are either active or inactive and can be linked by actions. The
actions of active steps are executed. The sequence of a GRAFCET is
described by the transitions from a previous to a subsequent step.
Steps and transitions have to alternate in the plan.

The creation and simulation of GRAFCETs in FluidSIM is illustrated


in the following using simple examples.

Drag a step into a newly created circuit diagram.

Figure 10/1: Simple step

Each step has to be assigned a name. All newly created steps are
consecutively numbered automatically. If a step is to be active at
the start of the sequence control, it is marked as the initial step.

Open the steps dialog box by double clicking it or via the


menu item Edit Properties... and select Initial step as the
type.

186 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 10/2: Step

Figure 10/3: Initial step

Start simulation with or via the menu ( Execute Start ).

Figure 10/4: Active step

Active steps are marked with a point. Additionally, active steps are
framed in green.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 187
10.3.2 Actions

To execute commands, you can link any number of actions to a


step. Actions do not have to be directly linked to a step; you can
also link them to each other. To make it easier to create the draw-
ing, it is enough to place actions next to each other, without having
to draw connecting lines. If the connections for the elements over-
lap each other, they are automatically connected.

Figure 10/5: Actions

Actions can be defined by a textual description or by setting (or


changing) variable values. If you want to simulate a GRAFCET with
FluidSIM, the variable values are taken into account in the simula-
tion. When displaying a GRAFCET graphically, you can decide
whether the variable name or the descriptive text is shown in an
action. If you want to display the description, you can set the
checkmark next to Display description instead of formula in the
actions properties dialogue (see example:
Grafcet/Grafcet18.ct). At View GRAFCET... , you can
specify whether the descriptions are displayed instead of the for-
mulae for all GRAFCET components.

There are two types of action: continuously effective and stored


effective actions. For a continuously effective action, its associated
variable is set to the Boolean value (logical value) TRUE (1),
provided that the step connected to the action is active. If the step
is inactive, the value is set to FALSE (0). This way of setting a
variable is referred to as assignation in the GRAFCET specifica-
tions.

For a stored effective action, the set value of the variable remains
unchanged until it is changed by another action. This way of setting
a variable is referred to as allocation in the GRAFCET specifica-
tions.

At the start of a sequence, all the variable values are initialized with
0.

188 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Create the following GRAFCET. Select the action Simple ac-
tion in the properties dialogue and enter A under Varia-
ble/output. Then start the simulation.

Figure 10/6: Action dialog window

Figure 10/7: Executed action

Step 1 is active and the action connected to the step is executed.


Variable A is set to 1. The value of an action variable is shown
during simulation in brackets after the variables name.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 189
10.3.3 Transitions

Transitions are used to describe the sequence of a control system.


To do this, add the following information to GRAFCET:

Figure 10/8: GRAFCET

Select 2 as the name of the second (simple) step. The transi-


tion conditions that specify when the system moves from one
step to the next are still missing. A transition is considered re-
leased once all the immediately preceding steps are active. A
transition is triggered once it has been released and its condi-
tion has the value 1. A transition with the value 1 is dis-
played in green in FluidSIM. You can show a descriptive text in-
stead of the formula, as with the actions.

A Boolean value is automatically generated for each step. The


name begins with an X, followed by the name of the step. In the
example here, the variables X1 and X2 are generated. The
value of a step variable is 1 if the step is active; otherwise it is
0.

Transition conditions can be time-dependent. These have the


following form:

t1 s / term / t2 s

Where t1 and t2 have to be replaced by numbers and term by a


Boolean term (s = seconds, ms = milliseconds).

190 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
The transition condition becomes true (1) t1 seconds after term
has changed its value from 0 to 1. This is called a rising edge.
The transition condition becomes false again (0) t2 seconds after
term has changed its value from 1 to 0. This is called a fall-
ing edge.

The short form t1 s / term is also allowed. The system then as-
sumes that t2 is 0 seconds.

Enter the transition conditions into the transitions' properties


dialogue as shown and then start the simulation.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 191
Figure 10/9: Transition dialog window

Figure 10/10: GRAFCET

The following cycle runs through:

192 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 10/11: GRAFCET cycle

10.3.4 Stored effective actions (allocations)

In the next example, a counter is to be implemented. This works


using a stored effective action (allocation) and an action on an
event.

To do this, add the following information to GRAFCET:

Select Action on activation for the action of the second step,


C as the variable and C + 1 as the allocation. C will work
as a counter. For the second action of the first step, select Ac-
tion on event, B as the variable with the allocation. 1 and
[ C>2] as the condition/event. Then start the simulation.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 193
Figure 10/12: GRAFCET

Each time step 2 is activated, C is raised by one. As soon as C


has the value 3 and step 1 is activated, B receives value 1.

Figure 10/13: GRAFCET simulation

10.3.5 GRAFCET-PLC component

The GRAFCET-PLC component is a control device based on a PLC,


the characteristics of which are described by a related GRAFCET.
The GRAFCET is simulated in isolation regardless of the set
GRAFCET mode, meaning that it has no direct access to the varia-
bles of other circuit components. The GRAFCET can only access the
input and output variables of the related GRAFCET-PLC component.

194 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 10/14: GRAFCET-PLC component

A GRAFCET-PLC component needs to be assigned to a GRAFCET.


This is normally the GRAFCET on the same page. However, you can
also specify a separate page in the project where the related
GRAFCET is located.

You can open the properties dialog box by double clicking. You can
access the adjustable parameters on the Component Parameters
tab.

Figure 10/15: Adjustable parameters of the GRAFCET-PLC compo-


nent

Related pages The GRAFCET plans on the specified pages will be assigned to the
GRAFCET-PLC component. If you do not specify any related pages,
the GRAFCET assigned will be the one on the same page as the
GRAFCET-PLC component.

Inputs This list defines the names of the input variables that can be evalu-
ated by the conditions of the related GRAFCET. Specifying a name is

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 195
optional. The input variable names I0 to I7 are created auto-
matically. The value of an input variables is set to 1 when a
voltage of at least 24 volts is applied to the corresponding electrical
connection and the GRAFCET-PLC component is connected to a
power supply.

Outputs This list defines the names of the output variables whose values
can be set by the actions of the related GRAFCET. Specifying a name
is optional. The output variable names Q0 to Q7 are created
automatically. A voltage of 24 volts is generated at the electrical
connection corresponding to an output variable if that output
variable has a value not equal to 0 and the GRAFCET-PLC compo-
nent is connected to a power supply. In any other situation, a
voltage of 0 volts is generated.

The following simple example illustrates the use of the GRAFCET


PLC component.

Figure 10/16: GRAFCET with its related PLC component

In the properties dialog box for the GRAFCET PLC component, the
alias E2 is entered for the input I2. The output Q5 was not
given an alias. As soon as the electrical switch is closed, there is a
potential at the input of I2; this potential causes the GRAFCET
variable I2 (and thereby also the alias E2) to change its value
from 0 to 1. As a consequence of this, the condition in the
action becomes true (1) and the value of variable Q5 is set to

196 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
1. This in turn leads to a potential being created at the output of
Q5 and the indicator light lights up.

Figure 10/17: GRAFCET simulation

If a GRAFCET is connected to a GRAFCET-PLC component, the


GRAFCET can only access the inputs and outputs of that related PLC
component. As the GRAFCET and PLC component may be on sepa-
rate pages, a frame around the GRAFCET during simulation indi-
cates that it is in this restricted PLC mode.

As soon as the switch is opened again, the following situation


arises:

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 197
Figure 10/18: GRAFCET simulation

10.4 Access to variables of circuit components

If the set GRAFCET mode permits it, GRAFCET elements can directly
access the variables of circuit components, with the GrafView
mode allowing only read access and the GrafControl mode allow-
ing both read and write access to the circuit variables. Also, to
permit this access, every variable used in GRAFCET needs to be
identifiable by a unique name. You can see the predefined name for
every variable in the component parameters dialog box. Clicking
the name of a variable opens another dialog box where you can
specify a user-defined alias. This alias is used like a global variable
and can be addressed directly in a GRAFCET.

198 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 10/19: Variables of a voltmeter

Read access to the variables listed in the component dialog box is


permitted. The complete variable name that can be used in a
GRAFCET is made up of the component identification, a dot . as a
separator, and the variable designation. The complete variable
name of the voltage of a voltmeter -M1 is therefore -M1.U, for
example. Alternatively, the user-defined alias can be used.

The complete variable name of the actuated state of a manually


operated switch -S is -S.state. For the sake of simplicity, an
alias with the switchs identification is created automatically. In this
example, therefore, -S can be used directly in a GRAFCET instead
of -S.state.

In the GrafControl GRAFCET mode, write access is possible only


to those variables which can actually be modified interactively
during the simulation. With a voltmeter, for example, the resistance
can be specified only in Edit Mode. It cannot be modified during the
simulation.

The following circuit (Grafcet/Grafcet19.circ) illustrates


access to circuit variables.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 199
Figure 10/20: Access to circuit variables

The GrafControl GRAFCET mode is set in the circuit properties,


otherwise the action could not act directly on the circuit. The condi-
tion checks if the voltage of voltmeter -M1 is greater than 10
volts. The complete variable name of the voltage is -M1.U as
described above, and is displayed on the action in the circuit. Once
the simulation starts, the voltage can be increased interactively in
the function generator. If the voltage exceeds 10 volts, the action
becomes active.

Figure 10/21: Access to circuit variables

The variable -S1 is set, which is an (automatic) alias of -


S1.state. This sets the state of switch -S1 to 1 (actuated) and
the switch opens.

200 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
10.5 Monitoring with GRAFCET actions

A GRAFCET can be used to monitor the proper functioning of a


fluidic or electrical circuit. The monitoring functionality in FluidSIM
allows you to check whether GRAFCET actions executed in a circuit
resulted in the desired behavior. This is done by evaluating so-
called monitoring conditions in the active actions during the simu-
lation. If a monitoring condition is violated, meaning that its value
is 0 (FALSE), the corresponding action is marked with a color and
the violation of the condition is tolerated for a defined time. Once
that time is exceeded, the monitoring is categorized as failed.

The settings for monitoring can be set along with the choice of
GRAFCET mode (see "Setting the GRAFCET mode").

Figure 10/22: Settings for GRAFCET monitoring

Enable monitoring Here you can define whether you want the monitoring to be carried
out during the simulation.

Monitoring condition false If the monitoring condition of an active action is violated, the action
is marked in the color specified.

Action failed Once a monitoring condition fails, or in other words, once the
tolerance time is exceeded, the corresponding action is marked in
the color specified.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 201
Pause simulation on action If this option is activated, the simulation switches to pause mode
failed when a monitoring condition fails.

Play sound on action failed If this option is activated, an audio signal is sounded when a moni-
toring condition fails.

The following example is designed to illustrate the use of GRAFCET


monitoring (Grafcet/Grafcet21_Hyd.circ or
Grafcet/Grafcet21_Pneu.circ).

Figure 10/23: Circuit diagram with GRAFCET monitoring

The single action in the GRAFCET activates the solenoid valve


directly. This should cause the cylinder piston to advance. A moni-
toring condition in the action will be used to check if the cylinder
actually did advance. A small positive velocity indicates the advanc-
ing of the piston.

To formulate the monitoring condition, open the properties dialog


box for the action by double clicking.

202 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 10/24: Specifying the monitoring condition

Monitoring condition The monitoring condition is entered in this field. Circuit variables
can be assigned to a unit of measurement by writing the desired
unit in square brackets after the variable. This is 1.3.v [m/s] in
the example shown.

Tolerance time In this field you enter the time period after which a violated condi-
tion is categorized as failed.

The Templates button opens a dialog box where a condition can


be compiled interactively.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 203
Figure 10/25: Template of a monitoring condition

Monitoring condition You can use the two drop-down lists to select a template of a moni-
toring condition.

Component Here you can specify the identification of the component to which
the monitoring condition will refer. You can use the Browse...
button to select the component from an additional selection dialog
box.

Variables / Units Here the variables and units are listed which are used in the select-
ed template.

Parameter Parameters can be adjusted in some templates. For example, in the


template Cylinder is in interval, you can specify the limits x1 and
x2 of the interval.

204 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Condition formula The condition generated from the template is shown as a formula in
this field. This formula is transferred into the input field for the
monitoring condition.

Start the simulation and observe how the GRAFCET controls the
circuit and advances and retracts the cylinder piston.

Figure 10/26: Simulation with GRAFCET monitoring

Now close the one-way flow control valve. The solenoid valve still
switches over as a result of the GRAFCET action, but the cylinder
cannot advance now. The monitoring condition of the action is now
violated and the action is marked in yellow to indicate this viola-
tion.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 205
Figure 10/27: Simulation with GRAFCET monitoring

After the set tolerance time of one second, the violated condition is
categorized as failed, the action is marked red, and the simulation
goes into pause mode.

206 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 10/28: Simulation with GRAFCET monitoring

10.6 Quick reference for the FluidSIM-relevant GRAFCET


concepts

The next sections introduce all GRAFCET concepts that are related
to FluidSIM.

10.6.1 Initialization

All the variables in a GRAFCET are preset with the value 0 at the
start of the simulation.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 207
10.6.2 Sequence rules

A transition is considered released once all the immediately


preceding steps are active. A transition is triggered once it has
been released and its condition has the value 1. A transition
with the value 1 is shown in green in FluidSIM, regardless of
whether the step linked to it is active or inactive.

The relevant transition is triggered at the same time and does


not take any time.

Since triggering a transition does not take any time, a step can
be activated and deactivated at the same time (even across
various intermediate steps). An active step remains active in
this situation. A loop of steps is only run through once at one
point in time (see example: Grafcet/Grafcet06.ct).

10.6.3 Sequence selection

A step can branch off into various partial sequences. In the


GRAFCET specifications, these partial sequences have to be exclu-
sive. Since this can generally only be checked during the sequence,
this exclusivity is not required in FluidSIM (see example:
Grafcet/Grafcet07.ct).

10.6.4 Synchronization

The GRAFCET synchronization component can be used to imple-


ment synchronizations (see example:
Grafcet/Grafcet08.ct).

208 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
10.6.5 Transient sequence / unstable step / virtual triggering

As described in Sequence rules, triggering a transition does not


take any time. As a consequence of this, multiple consecutive steps
can be activated at the same point in time one after the other. This
sequence is called transient (continuous).

The intermediate steps in the sequence chain are referred to as


unstable. The continuously effective actions connected to them are
not displayed in the simulation. The allocations in the stored effec-
tive actions are carried out. Triggering the intermediate steps and
their associated transitions is called virtual triggering (see example:
Grafcet/Grafcet06.ct).

10.6.6 Determining the values of GRAFCET variables

Variables of continuously effective actions (allocations) receive the


value 1 if the corresponding action is linked to an active step and
any action condition present has the value 1.

Variables of stored effective actions (assignation) are changed if


the corresponding action is linked to an active step and the rele-
vant action event occurs (e.g. action on event or on activation).

FluidSIM does not check whether the two types of variable identifi-
cation contradict each other for a variable. If this case occurs, the
variable value is determined by an internal calculation, which the
user cannot predict (see example: Grafcet/Grafcet09.ct).

10.6.7 Checking the entries

FluidSIM checks the validity of entries for conditions and assigna-


tions. If this kind of term does not match the specifications, the

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 209
term in question is displayed in red. The simulation is only released
once all the terms are valid.

10.6.8 Admissible characters for steps and variables

Steps and variables cannot contain any spaces. Function names


that can be used in a GRAFCET expression are not permitted.

There are no limitations for the descriptions that can be shown for
conditions and actions, because these are only displayed and are
not used for simulation.

10.6.9 Variable names

There are four different types of variables. All variables can be used
in conditions and assignations.

Action Variables Action variables are available throughout GRAFCET and can be set
in actions (see example: Grafcet/Grafcet10.ct).

Step Variables Step variables are inserted automatically for each step and have
the value 1 when and only when the corresponding step is active.
Step variables have the form X + step name. If, for example, the
step name is 12, then the associated variable is X12. Step
names are only ever valid within a partial GRAFCET or within the
global GRAFCET. This means that the same step name can be used
in different partial GRAFCETs. In order to be able to address step
variables across partial GRAFCETs in FluidSIM, the step variable has
to be preceded by the partial GRAFCET name. Example: Partial
GRAFCET 1 contains step 2 and is meant to be addressed in the
global GRAFCET. Within the global GRAFCET, the step variable name
G1.X2 has to be used. Within partial GRAFCET 1, X2 is
enough (see example: Grafcet/Grafcet11.ct). Variables of
macro-steps have the form XM + step name, macro inputs have
XE + step name and macro outputs have XS + step name (see
example: Grafcet/Grafcet15.ct).

210 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Partial GRAFCET Variables Partial GRAFCET variables are automatically inserted for each
partial GRAFCET and have the value 1 when and only when at
least one step in the corresponding partial GRAFCET is active.
Partial GRAFCET variables have the form XG + partial GRAFCET
name. If, for example, the partial GRAFCET name is 1, the asso-
ciated variable is XG1 (see example:
Grafcet/Grafcet12.ct).

Variables of circuit compo- The variables of circuit components can be used in GRAFCETs as
nents input and output variables (see "Access to variables of circuit
components").

10.6.10 Functions and formula entry

A range of functions can be used in conditions and assignations.


These functions are displayed according to the GRAFCET specifica-
tions (e.g. upwards arrow for rising edge). Entering GRAFCET-
specific functions is supported by the buttons in the dialogues with
the relevant labels:

+ (logical OR)

* (logical AND)

NOT (logical NOT)

RE (rising edge)

FE (falling edge)

s / / s (delay)

s / (delay, short form)

NOT(s /) (time limit)

If the functions NOT, RE or FE refer to a term, the term has to


be placed in brackets.

Examples:

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 211
NOT a

NOT (a + b)

RE X1

RE (X1 * X2)

The following additional mathematical functions are available:

abs (absolute amount)

sign (algebraic sign: +1, 0, -2)

max (maximum of two numbers)

min (minimum of two numbers)

^ (to the power of, e.g. a^3)

sqrt (square root)

exp (to the power of constant e)

log (natural logarithm)

sin (sine)

cos (cosine)

10.6.11 Delays / time limits

Delays have the following form (see example:


Grafcet/Grafcet03.ct):

Time in seconds s / Boolean term / time in seconds

or

Time in seconds s / Boolean term

212 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Examples:

1 s / X1 / 2s 3s/X3

Time limits have the following form:

NOT (time in seconds s / Boolean term)

Example: NOT(6s/X28)

In addition to s for seconds, the following units of time can also


be used.

d (days)

h (hours)

m (minutes)

s (seconds)

ms (milliseconds)

Time specifications can also be combined, e.g. 2s500ms for 2.5


seconds.

10.6.12 Boolean value of an assertion

In GRAFCET, you can use Boolean values to calculate an assertion,


for example: a counter C should be larger than 6 and step X1
should be activated. C is larger than 6 can be calculated as with
a variable. To do this, the assertion has to be set in square brack-
ets. So in this example:

[C > 6 ] * X1

If a Boolean assertion is positioned on its own in a condition, then


you can omit the square brackets in FluidSIM, for example C > 6
instead of [C > 6]. (See example:Grafcet/Grafcet13.ct)

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 213
10.6.13 Target information

If you want to interrupt an operative connection from a transition to


a step, you can enter the name of the target step in the transitions
properties dialogue (see example: Grafcet/Grafcet14.circ).

10.6.14 Partial GRAFCETs

Partial GRAFCETs can be used to separate a GRAFCET into different


hierarchy levels. This function is most often used for enclosing
steps and compulsory commands. The name of a partial GRAFCET is
always preceded by a G.

In order to determine partial GRAFCETs in FluidSIM, the partial


GRAFCET frame has to be placed over the relevant GRAFCET part
and you have to assign a name in the properties dialogue. The
preceding G is not part of the name that you have to enter; it is
added automatically by FluidSIM and shown at the bottom left of
the partial GRAFCET frame. You can alter the size of the partial
GRAFCET frame by dragging its edges with the mouse (see exam-
ple: Grafcet/Grafcet11.ct). It is important that all the ele-
ments of the partial GRAFCET are located entirely within the rele-
vant frame and that there are no foreign elements overlapping
the frame.

10.6.15 Macro-steps

Macro-steps can be specified using a steps properties dialogue.


The preceding M is not a part of the name that you have to enter;
it is added automatically by FluidSIM. You can specify macro inputs
and macro outputs in the same way. The preceding E and S in
these cases are not part of the name either and are automatically
added by FluidSIM (see example: Grafcet/Grafcet15.circ).

214 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
10.6.16 Compulsory commands

Compulsory commands can be used to control partial GRAFCETs


regardless of their normal sequence. There is an entry mask to help
you enter these commands in FluidSIM. There are four types of
compulsory command. They are shown here using four examples
(see example: grafcet/Grafcet16.circ).

G12 {8, 9, 11} Setting a specific situation. This example activates steps 8, 9 and
11 of partial GRAFCET 12.

G12 {*} Freezing a partial GRAFCET. In this example, the current situation
for partial GRAFCET 12 is maintained as it is. No further transitions
are triggered.

G12 Setting a blank situation. All steps in partial GRAFCET 12 are deac-
tivated in this example.

G12 {INIT} Setting the initial situation. In this example, the steps in partial
GRAFCET 12 that are marked as initial steps are activated.

10.6.17 Enclosing step

Enclosing steps can be specified using a steps properties dialogue.


You can either enter the enclosed partial GRAFCETs directly or
select them from a list. You have to separate individual partial
GRAFCETs with a comma or a blank space.

During simulation, the name of the enclosing step is shown at the


top left of the partial GRAFCET frame, as soon as the step is activat-
ed (see example: Grafcet/Grafcet17.ct).

You have to set the Activation link field in the properties dialogue
for steps within the enclosed partial GRAFCET that you wish to
activate when the enclosing step is activated.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 215
10.6.18 Action when a transition is triggered

An action on triggering is a stored effective action which is execut-


ed when the transition connected to the action is triggered. The
action is usually connected to the transition by a straight line (see
example Grafcet/Grafcet20.circ).

216 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Dimension

Chapter 11
11. Dime nsion

FluidSIM allows both automatic and manual dimensioning.

11.1 Draw dimension

The buttons

Horizontal

Vertical

Align

Angular

Flag

activate the corresponding mode for drawing the dimension ar-


rows. Alternatively you can also access the dimensioning functions
in the Draw menu under Dimension .

Horizontal, vertical and diagonal dimensioning is done by defining


two points for the distance as well as then clicking to position the
dimension text. Angular dimensioning requires the center point to
be defined as well as two points for the angle. The fourth click in
turn defines the position of the dimension text. The Flag dimen-
sion function can also be used for general labeling of important
points in the circuit. Two points for a line with any pitch and a final
click for the text are needed for this.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 217
11.2 Settings for the dimension

Figure 11/1: Dimension dialog window

Layer Defines the drawing layer for the dimension.

Automatic Dimensioning Activates or deactivates automatic adaptation of the dimension


when the dimension length is changed.

Length If the Automatic Dimensioning option is deactivated you can enter


any number that will be displayed as the length dimension. A unit
can also be selected. Show Unit defines whether the unit should be
displayed.

Decimals Defines the number of decimal places.

Factor Determines the factor by which the real length is multiplied for the
displayed value. This is necessary if you are creating a drawing with
a scale other than 1:1.

Color Defines the color for the dimension.

218 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Line Style Defines the line style for the dimension.

Line Width Defines the line width for the dimension.

Dimensions, like all other objects in FluidSIM, can be moved, rotat-


ed, mirrored and scaled. The display value of the dimension is
automatically adapted during scaling if the Automatic Dimension-
ing option is activated.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 219
Component attributes

Chapter 12
12. Compone nt attributes

The FluidSIM circuit symbols largely correspond to the components


in the equipment sets from Festo Didactic GmbH & Co. KG. The
parameters of the components are also entered accordingly in
FluidSIM. Open the Properties dialog window for a component by
double clicking a symbol or by opening the Edit menu and select-
ing Properties... .

220 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
12.1 Component attributes in the Properties dialog window

Figure 12/1: Properties dialog window for a component:

The properties of a component are saved in attribute value pairs.


The attributes are divided into different groups. The first group
contains the general properties:

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 221
Figure 12/2: Detail from the Properties dialog window for a compo-
nent: General properties

Symbol Name Displays the name of the circuit symbol. The symbol name is
mapped to appropriate products in the Festo product catalogue.
Users cannot edit the symbol name.

Description Contains a more detailed description or the complete name of the


circuit symbol where applicable. Users can edit this. The identifica-
tion is shown as text in the circuit drawing if the Display option is
selected.

Part number The part number uniquely identifies a product within parts lists.

Layer In this selection list you define the drawing layer for the symbol.
Depending on the setting for the drawing layer it may not be possi-
ble to display or edit the symbol. In order to make the symbol
visible or change the settings you have to temporarily activate the
drawing layer on the Drawing Layers... menu item from the View
menu.

Identification Here you can assign an identification that uniquely identifies the
component in the circuit diagram. The identification is shown as
text in the circuit drawing if the Display option is selected.

Note: FluidSIM automatically assigns a unique identification when


inserting or copying circuit symbols. An automatically assigned
identification text begins with a question mark and can be edited by
the user (FluidSIM shows a warning if you are assigning an identifi-
cation that already exists).

Display in Parts Lists Deactivate this option if you do not want the symbol to appear in
the parts list.

222 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
12.2 User Defined Properties

You can enter your own component attributes in the User Defined
Properties tab.

Figure 12/3: Detail from the Properties dialog window for a compo-
nent: User Defined Properties tab

In order to edit an entry the corresponding row must be selected by


clicking on it. Clicking on the table cell to be modified again then
enables you to edit the entry in the cell.

A row can be deleted by first clicking the row to highlight it. The
highlighted row can then be deleted using the Del key.

You can add any desired attributes by filling out the empty cells on
the last row.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 223
12.3 Drawing Properties

You can enter a number of drawing properties that influence how


the symbols are displayed in the circuit diagram in the Drawing
Properties tab.

Figure 12/4: Detail from the Properties dialog window for a compo-
nent: Drawing Properties tab

Scale Defines the scaling in the x or y direction. The scaling factor can
also be defined with the help of the mouse pointer. This is de-
scribed in the Scale symbols section.

Rotation Defines the angle of rotation in degrees. The angle of rotation can
also be defined with the help of the mouse pointer. This is de-
scribed in the Rotate symbols section.

Override Color If this option is activated then another color can be selected for the
symbol.

Reset Resets the geometrical settings to the default values: Scaling to 1,


rotation to 0 and Override Color deactivated.

224 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
12.4 Main and secondary components

As described under Component attributes in the Properties dialog


window, the FluidSIM circuit symbols largely correspond to the
components in the Festo product catalogue. These symbols are
called main components. However there are also secondary com-
ponents, which do not correspond to components in the Festo
product catalogue. These secondary components are usually sym-
bolic representations of a partial aspect of an associated main
component.

All product properties are stored in the main component. The


secondary components only have a description and a reference to
the associated main component. In electrical engineering in par-
ticular, components such as relays are divided into main and sec-
ondary components where the coil is the main component and the
contacts are the secondary components.

12.5 Linking main and secondary components

Main and secondary components are linked using the symbol for
the secondary component. The circuit diagram detail shows a relay
comprising a coil as the main component and two contacts as the
secondary components. The contacts are to be linked with the coil.
This information is evaluated when displaying the contact image.

Figure 12/5: Relay comprising coil with two contacts

The symbol identifications are the defaults used in FluidSIM. The


symbols are not linked together yet.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 225
Open the corresponding properties dialog window by double-
clicking a contact.

Figure 12/6: Properties dialog window for a contact

Description Defines a description for the secondary component. In the case of a


contact, this is shown in the terminal diagram.

Main Component A compatible main component can be selected from a list. The main
component identification can also be entered directly as text.

Browse... Opens a dialog that shows all compatible main components as a


tree in accordance with the object hierarchy.

Link If this box is checked then the secondary component is logically


linked with the main component. If the main component is then
renamed, the link is retained and the identification of the linked
secondary component is adapted as appropriate to the main com-
ponent identification.

Find Target... If the secondary component is logically linked with a main compo-
nent, a search can be performed for the associated main compo-
nent using this button.

Display If this box is checked then the main components identification is


shown as the identification for the secondary component.

226 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Select Q1 from the list of compatible main components.
Proceed in the same way for the second contact.

Selecting from the list of compatible main components automatical-


ly establishes the logical links between the contacts and the coil.
The circuit diagram should now look as follows:

Figure 12/7: Relay comprising coil with two contacts

If you now change the coil identification to Q2, the logical links
mean that the identifications at the contacts will also be automati-
cally changed to Q2.

Examples of this are relays with the coil as the main component and
the contacts as secondary components as well as electromagnetic
directional control valves with the pneumatic symbol as the main
component and the valve solenoids as secondary components in
the electrical part of the circuit diagram.

12.6 Link solenoid valves and solenoid coils

The coils belonging to solenoid valves are usually displayed sepa-


rately in the electrical part of a circuit diagram. The link between a
solenoid valve and the associated coils is defined at the solenoid
valve symbol.

The following circuit diagram shows a solenoid valve and the sym-
bols for two separate solenoid coils. No link has been established
yet between the solenoid valve and the coils.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 227
Figure 12/8: Solenoid valve and two separate coils

There are two ways of establishing a link between a solenoid valve


and a coil. The first is using the properties dialog window for the
solenoid valve.

Open the appropriate properties dialog window by double-


clicking the solenoid valve and select the Connector Labels tab.

228 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 12/9: Properties dialog window, Connector Labels tab

This tab shows all of the solenoid valves connectors. Connectors


refer, among other things, to the logical connection options for the
solenoid coils. The input fields of the left-hand electric connector
are described below. The descriptions apply analogously to the
right-hand connector and other types of logical connectors.

Electric Connector (Left) The identification for the left-hand solenoid coil can be entered in
this list box or selected from a list. When you click in this field the
corresponding connector is highlighted in the preview. This helps to
locate the connector, particularly when dealing with turned or
mirrored symbols.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 229
Browse... Opens a dialog that shows all compatible solenoid coils as a tree in
accordance with the object hierarchy.

Link If this box is checked then the solenoid coil is logically linked with
the connector at the solenoid valve. If the solenoid coil is renamed
the link is retained and the identifications of the coils at the sole-
noid valve are changed to match the coil identifications.

Find Target... If the connector at the solenoid valve is logically linked with a coil a
search can be performed for the associated coil using this button.

Display If this box is checked the coils identification is shown as the identi-
fication for the solenoid valve connector.

Select -K1 from the list of compatible solenoid coils.

Figure 12/10: Left connector linked with coil -K1

The second way of linking a solenoid valve with a coil is to double-


click the solenoid valves connector directly. The coil connectors are
represented like pneumatic connectors within the solenoid valve by
means of small circles.

Double-click the right connector of the solenoid valve.

A dialog window whose fields correspond to the entries for a con-


nector in the Connector Labels tab of the Properties dialog window.

230 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 12/11: Connector dialog window

Select -K2 from the list of compatible solenoid coils.

The (electric) connectors of the solenoid valve are now linked with
the solenoid coils.

Figure 12/12: Link solenoid valve and solenoid coils

12.7 Attributes of the text components

In FluidSIM text components serve, firstly, to insert comments and


labels and, secondly, can be defined by the labels and accessories
without displaying a symbol. Open the dialog window Properties of
the text component by double-clicking on a text or via the Proper-
ties... menu item on the Edit menu.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 231
Figure 12/13: Properties dialog window for a text component:

A text component possess all of the attributes of a standard com-


ponent. The text properties are located on the Edit Text tab.

232 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 12/14: Detail from the Properties dialog window for a text
component: Edit Text tab

Edit Text Enter your text into the input field on the left-hand side. You can
also enter text with multiple lines. Press the Enter key to create a
line break.

Alignment Defines the horizontal or the vertical alignment of the text within
the text field.

Font... Defines the text font.

Color... Defines the text color.

Frame Text Draws a frame around the text field.

Attribute Link If this option is activated a text that identifies a link to an attribute
is displayed instead of the text entered. The value of the selected
attribute is displayed in the circuit diagram. You can find a detailed
description of this function under Link text components with attrib-
utes. A predefined placeholder such as the page number can also
be selected using the Predefined variable... button.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 233
12.8 Link text components with attributes

Text components can also display attributes of other components,


values of predefined placeholders, attributes of a circuit or the
project. The text component must be linked to the corresponding
attribute for this. The linked attribute is defined in the input field of
the Edit Text tab in the Properties dialog window for the text
component. The activated Attribute Link option defines that the text
in the text field should not be displayed but rather interpreted as a
link.

Example:

Assuming that your project is called Project1 and possesses the


Supplier attribute with the value Festo. You project contains
the Circuit1 circuit and you would like to display the value of the
Supplier attribute, in this example namely the value Festo, in
this circuit diagram.

Insert a text component into the circuit drawing by selecting


the text element on the drawing elements toolbar and then left-
clicking the circuit drawing. The Properties dialog window for
the text component then opens.

Note: You can open the dialog window of an existing text compo-
nent by double-clicking it or using the Edit menu and the Prop-
erties... menu item.

Activate the Attribute Link option and then click the Browse...
button.

A window opens displaying the hierarchy of all of the available


attributes. Please note that only those objects are listed that have
an identification assigned by the user. Identifications beginning
with a question mark ? are not listed. These are identifications
that have been automatically assigned by FluidSIM. The desired
attribute is located under Attribute Tree - Project1 - Supplier.

234 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 12/15: Browse Attributes dialog window

Select Supplier and then click the Select button.

The Project1.Supplier value is displayed in the input field and


Festo in the preview. The complete and unique name of the
attribute contains all of the hierarchy levels beginning at the pro-
ject. The individual layers in the name are separated by a full stop.
It is also possible to enter only the attribute name into the input
field. In this example: Supplier. The hierarchy is then searched
from the bottom up for the attribute, beginning with the text com-
ponents. If the attribute searched for is not found in that compo-
nent then the circuit and then the project are searched for the
attribute.

If the attribute is not found then the attribute name is displayed in


the circuit diagram in angle brackets. The missing attribute can be
created at a later point in time. The link is then created automatical-
ly.

The concept of linking text components with attributes is also


utilized for labeling von drawing frames.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 235
12.9 Text components with specified links

Text components are automatically generated for displayable


component attributes and connector labels which are linked to the
corresponding attributes. Open the Display Attribute dialog window
with which you can adjust how the text is displayed by double-
clicking on the text component or via the Properties... menu item
on the Edit menu.

Figure 12/16: Display Attribute dialog window

Alignment Defines the horizontal or the vertical alignment of the text within
the text field.

Scale Defines the scaling factor of the text in the x or y direction.

Note: You can also change the text size by selecting another font
size in the font type dialog window. You open this dialog window
using the Font... button under Text Attributes.

Rotation Defines texts angle of rotation in degrees.

Font... Defines the text font.

236 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Color... Defines the text color.

Frame Text Draws a frame around the text field.

Find Target... The target of a linked text is the attribute which the text refers to.
This button opens the Properties dialog window of the object which
contains this attribute.

12.10 Change the properties of multiple objects simultaneously

If multiple objects are selected, choosing the Properties... menu


item on the Edit menu opens a dialog window with a limited
selection of properties. It only contains those properties which
meaningfully relate to all of the selected objects. This enables you
to change the font for multiple texts in a single operation, for ex-
ample. The more different object types (symbols, connectors,
drawing elements, texts, etc.) that are selected, the less common
properties are available.

The following tabs are available for the common properties de-
pending on the objects highlighted.

12.10.1 Drawing Properties

The dialog elements available within a tab depend on the objects


highlighted.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 237
Figure 12/17: Properties dialog window, Drawing Properties tab:
several highlighted objects

Font... Defines the font type of the text.

Frame Text Draws a frame around the text field.

Scale Defines the scaling factor of the text in the x or y direction.

Rotation Defines the angle of rotation of the text field in degrees.

Override Color Defines the color of the drawing element.

Line Style Defines the line style.

Line Width Defines the line width.

Start Cap Defines how the beginning of the line is displayed.

End Cap Defines how the end of the line is displayed.

Background Sets the location of the drawing element to the background. This
means that all of the circuit symbols are on top of this. In particular
this means that symbols are not covered by filled drawing ele-
ments, for example.

238 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Foreground Sets the location of the drawing element to the foreground. This
means that all of the circuit symbols are underneath this. In particu-
lar it means that symbols are covered by filled drawing elements,
for example.

Reset Reset the settings to the default values.

12.10.2 Main Component

Figure 12/18: Properties dialog window, Drawing Properties tab:


several highlighted objects

Main Component A compatible main component can be selected from a list. The main
component identification can also be entered directly as text.

Browse... Opens a dialog that shows all compatible main components as a


tree in accordance with the object hierarchy.

Link If this box is checked then the secondary component is logically


linked with the main component. If the main component is then
renamed, the link is retained and the identification of the linked
secondary component is adapted as appropriate to the main com-
ponent identification.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 239
Find Target... If the secondary component is logically linked with a main compo-
nent, a search can be performed for the associated main compo-
nent using this button.

240 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Parts list management and analyses

Chapter 13
13. Parts list manage ment a nd a nalyses

Various analyses can be inserted into a circuit diagram using the


Insert menu item. Alternatively you can also use the button on
the toolbar. The following dialog window opens.

Figure 13/1: List/Table... dialog window

The following analyses can be inserted into the circuit diagram


using this dialog: Parts List , Terminal diagram , Cable Map ,
Cable List , Wiring List and Tube List .

The use of parts lists is described below. The use and function of
the other analyses are described in the corresponding chapters.

FluidSIM creates parts lists that are automatically updated in the


background while the circuits are being edited.

If a parts list has been added to a circuit diagram as described


above it can be used like a symbol. The use of parts lists as a spe-
cial page type is described under Display parts list.

You can customize the appearance of the parts list under Proper-
ties... in the Appearance tab. You can see the effects of the
settings straight away in the preview on the right-hand side.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 241
If the Lines per Page option is selected you can specify the num-
ber of lines to be displayed per page. The relevant pages will also
be output when the circuit diagram is printed. Buttons for naviga-
tion are displayed underneath the page if the list is split across
multiple pages.

Figure 13/2: Buttons for navigating through lists

13.1 Display parts list

We recommend setting up one file specifically for the parts list in a


project. If you wish to create a circuit drawing without creating a
project you can switch the view for this circuit to the parts list view.
Selecting the Parts List menu item from the View menu enables
you to switch from the circuit view to the parts list view. Conversely,
selecting the Circuit Diagram menu item from the View menu
enables you to switch from the parts list view to the circuit view.

A parts list is displayed as a table in the window. You can edit the
following options for editing the table:

Attributes which the user can edit can be entered directly into
the corresponding table field.

Clicking on the column header sorts the rows on the basis of


the column clicked. Clicking on the head of the same column
again reverses the sorting order.

You can adjust the column width by dragging the edges of a


column header.

You can change the order of the columns by dragging and


dropping a column header in another position.

242 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
13.2 Find components from the parts on the circuit diagram

FluidSIM enables you to easily find components on the parts list in


the circuit diagram and vice versa.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 243
Figure 13/3: Finding components from the parts list

You have the following options:

Clicking on the Find... button on the Find Target parts list


column switches to the circuit diagram display and an anima-
tion identifies the corresponding components. If the same cir-

244 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
cuit diagram is already open in another window than the parts
list view remains in the active window. The already opened
window containing the circuit diagram is moved into the fore-
ground and an animation identifies the corresponding circuit
diagram symbol.

When you click a cell in the parts list table an animation identi-
fies the corresponding component in all of the opened windows
displaying the circuit diagram.

If you click a column header in the parts list table then both the
entire column of the parts list as well as the corresponding
components in the associated circuit diagram windows are se-
lected.

If you click a component in a circuit diagram then both this


component and the corresponding row in the open parts lists
are selected.

13.3 Set parts list properties

In the parts list view clicking on the Properties... button opens


the Parts List Properties dialog window.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 245
Figure 13/4: Parts List Properties dialog window: Included Pages
tab

Accumulated Parts List Compiles the components with the same attributes.

Single Position Parts List Lists all of the components individually

Sort as Number Interprets the column contents as numbers, so that 10 appears


after 2, for example.

Include This Pages Compo- Only lists the components of the corresponding circuit diagram.
nents Only
Include All Project Files Lists all of the components of the active project.

Include Selected Files: Lists all of the components of the selected circuit diagrams belong-
ing to the active project.

246 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 13/5: Parts List Properties dialog window: Listed Attributes
tab

List All Attributes Lists all of the component attributes within a parts list row.

List Selected Attributes: Only lists selected component attributes within a parts list row.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 247
Figure 13/6: Parts List Properties dialog window: Print Options tab

In this tab you can adjust the appearance of the parts list printout.
In the preview on the right-hand side you can immediately see the
effects of the adjustments. You can find information regarding
printing a parts list in the Print circuit diagram and parts list
section.

13.4 Export parts list

You can export the parts list as a text file.,

Click the Export... button in the parts list view.

248 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
A dialog window for selecting a file or entering a new file name
appears. After you have entered a file and left the dialog field you
can define the following format settings for the export in the Parts
List Export dialog window:

Figure 13/7: Parts List Export dialog window

Column Header If this option is selected then the names of the attributes appear in
the first row of the text file.

Quotation Marks Select this option to set the field elements in quotation marks.

Delimiter The selected separator is used to separate the columns.

13.5 Insert tube list

You can insert a tube list into a circuit diagram.

In the Insert menu, select Tube List to insert a tube list into
the circuit diagram. Alternatively you can click the button.
In the selection dialog box that opens, select Tube List .

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 249
The mouse pointer changes to a crosshair. Click the position in the
circuit diagram where you want to insert the tube list. A dialog
window then opens where you can select the associated tubing and
customize the appearance.

Figure 13/8: Tube List dialog window, Included Pages tab

Include This Pages Compo- Lists only the tubes in the associated circuit.
nents Only
Include All Project Files Lists all tubes in the active project.

Include Selected Files: Lists all tubes in the selected circuit in the active project.

250 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 13/9: Tube List dialog window, Appearance tab

You can customize the appearance of the tube list on the Appear-
ance tab. You can see the effects of the settings straight away in
the preview on the right-hand side.

If the Lines per Page option is selected, you can specify the
number of lines to be displayed per page. The relevant pages will
also be printed in a printout of the circuit diagram. Buttons for
navigation are displayed underneath the page if the list is split
across multiple pages.

Figure 13/10: Buttons for navigating through lists

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 251
Manage projects

Chapter 14
14. Manage pr ojects

FluidSIM supports the management of projects by compiling differ-


ent files under one name in a single project file. This has the fol-
lowing benefits: When opening a project all of the associated data
is loaded. It is possible to rapidly access files belonging to a project
via the project window. Parts lists whose elements are located in
different circuit diagram files can be maintained in one project.

14.1 Create new project

Select the New... / Project... menu item from the Project


menu and enter a file name for the new project.

Project files possess the prj file suffix. By default they only contain
links to files contained in the project. If you wish to pass on a
project then you must either pass on all of the associated files
along with the project file or activate the Save Projects as Single
File option.

When creating a new project, a project folder is automatically


created to store the project file and all other files belonging to the
project. This automatically created project folder has the same
name as the project file. If you create the project file in an empty
folder this will be used for the project (i.e. another new folder will
not be created underneath it). The automatic creation of project
directories can be activated and deactivated in the options under
Save.

In the project window a project is represented hierarchically as a


list. The top element is the project node. Below this are the associ-
ated circuit nodes and parts list nodes which can be differentiated
from each other via the symbol in front of the name.

252 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
14.2 Project nodes

Every project possesses one project node as the uppermost ele-


ment. All of the project-specific properties are saved with the pro-
ject node. Right-clicking on a project node opens a context menu.
You can also find the menu items on the Project menu. Here you
can find the functions for adding and removing files, among other
things.

Under the Properties... menu item from the Project menu you
can define properties for the project. Properties that can be speci-
fied for both projects and circuits are described under Circuit and
project properties.

14.2.1 Project archiving

Project files generally consist of links to the files contained therein.


However, where desired FluidSIM can also save the project along
with all of the associated files in one single file. Among other
things, this makes it easier to pass on the project. Activate the Save
Projects as Single File option in the Archiving tab.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 253
Figure 14/1: Project dialog window: Archiving tab

Save Projects as Single File If this option is activated all of the files belonging to the project are
saved in a single file.

Please note the advice displayed under this option.

14.3 Circuit and parts list nodes

A circuit node is created beneath the project node for every circuit
file that belongs to the project. This also applies to parts lists since
they are saved as circuits. These are just displayed differently in the
window. All of the circuit-specific or parts list-specific properties are
saved with the circuit node.

Right-clicking a circuit node opens a context menu containing the


following menu items:

Open...

Opens the selected circuit or the selected parts list in a window.


Double-clicking on the node in the project tree also opens the
window.

254 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Close Windows Closes the window of the selected circuit or the selected parts list.

Remove From List Removes the selected circuit or the selected parts list from the
project.

Rename... Changes the description of the selected circuit or the selected parts
list.

Properties... In this dialog window you can enter data for the circuit or parts list.

Note: Please note that the additional parts list-specific properties


can be set using the window view of the parts list.

Figure 14/2: Page dialog window: Drawing Size tab

Here you can define the circuit dimensions and orientation, both of
which are relevant for printing.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 255
Circuit and project properties

Chapter 15
15. Circuit and project pr operties

Circuits and projects have a host of common properties. The prop-


erties set in the project can be used by circuits in the project. All of
the properties that can be specified for both circuits and projects
are listed below. The screenshots shown are dialog windows for the
circuits.

Figure 15/1: Properties dialog window

Properties The file name field displays the file name of the circuit or project
along with the complete path. The file name is carried over to the
input field for the Description and can be edited there. This entry
is displayed in the upper margin of the window as well as beside
the circuit or project node.

Page number Here you can specify a page number. The page number can be
made up of any character string. The page number can be defined
using the %PageNumber predefined placeholder. This placehold-
er can be used in text components and drawing frames among
others.

256 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Drawing Frame Here you can make settings for the drawing frame. This function is
described in the section Drawing frame.

15.1 Attributes

Any number of attributes can be created for every circuit or node in


a project. The attributes are listed in a table in the Attributes tab.
New attributes can be entered in the empty cells at the end of the
table. The use of attributes is described in the section Attributes of
the nodes in a project.

The attributes of a project node are automatically copied to all


circuit and parts list nodes (inherited) and are thus available in all
of the circuit drawings. This concept is particularly useful for the
drawing frames if project attributes are to be displayed in the
circuit diagram, for example. You can find further information in the
section Link text components with attributes.

Circuit attributes copied from a project cannot be edited initially.


The corresponding row in the Attributes tab of the Page dialog
window is grayed out and the Inherit From Project option in the
column is activated.

However it is possible to overwrite a copied attribute in a circuit.


The option in the Inherit From Project column must be deactivat-
ed for this. The value of the attribute can then be edited. This
function can be used to assign individual page numbers in the
drawing frame, for example. If the Inherit From Project option is
reactivated then the attribute value is copied from the project
again.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 257
Figure 15/2: Attributes tab

Attribute This column contains the name of the attribute.

Value This column contains the value of the attribute.

Action The buttons in this column allow the following actions: if the attrib-
ute was created in the parent project node then the Find Target...
action is available. Clicking this opens the Project or Circuit dialog
window for the project node as the target that contains the corre-
sponding attribute. If the attribute was created in the same node
then the Delete action that allows you to delete the attribute is
available.

Inherit From Project If the attribute was created in the same node then this option is
deactivated and grayed out. This applies to all of the attributes of
the project node since it does not have a parent node. For child
nodes the value of the attribute from the project node is copied
when this option is activated. After deactivating this option it is
possible to locally overwrite the attribute value.

Comment Here you can enter a comment about the attribute.

258 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
15.1.1 Predefined placeholders

FluidSIM provides a host of predefined placeholders. These place-


holders can be used in text components and drawing frames among
others.

The placeholders begin with a percentage sign. The following


predefined placeholders are some of those available:

%PageNumber

The page number is specified in the properties dialog window for


the circuit diagram.

If analyses are split across several pages, the number of the sub-
page is added to the page number with a minus sign. If, for exam-
ple, the entered page number is 42-01 and the page displayed is
the third page in an analysis then the placeholder %PageNumber
is replaced by the character string 42-01-03.

%PageDescription The description for the page is specified in the properties dialog
window for the circuit diagram.

%PageFileName Stands for the file name of the page without the file path.

%PageFullFilePath Stands for the file name of the page with the full file path.

%PageFileDateTime Stands for the date and time of the most recent change to the
circuit diagram.

%PageFileDate Stands for the date of the most recent change to the circuit dia-
gram.

%PageFileTime Stands for the time of the most recent change to the circuit dia-
gram.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 259
15.2 Page Dividers

Page dividers can only be defined for pages. Editing of page divid-
ers is described under Page dividers.

15.3 Basic Unit Length

The symbols in the FluidSIM symbol libraries are created according


to various DIN ISO standards. Instead of specifying absolute units
of length, the standards simply use a relative basic unit of length
M. All of the symbols have been created with reference to this
basic unit of length M. The actual size of the symbol is not de-
fined until the symbol is inserted into a circuit.

Information on how to convert the basic unit of length M is stored


with the circuit diagram. You can change the set values for a circuit
diagram by calling up the properties dialog window for the circuit
diagram using the Page Properties... menu. You will find the
relevant settings in the Basic Unit Length tab.

260 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 15/3: Basic Unit Length tab

As soon as the value of M is changed, the sizes of the existing


symbols are recalculated with respect to the specified basic unit of
length. The specification has no effect on elements in the drawing
frame.

The Basic Unit Length tab is also in the project settings. The set-
tings made in this tab are used as a template for circuit diagrams
created from new in the project tree.

15.4 Encryption

Projects and circuit diagrams can be encrypted. The encryption


method used is AES-128.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 261
Figure 15/4: Encryption tab

Enable Encryption This option activates and deactivates encryption. When encryption
is activated the password to be used can be entered in the Pass-
word input field.

262 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
15.5 Cross Reference Representation

Figure 15/5: Cross Reference Representation tab

This tab is used to define the settings for the cross-reference repre-
sentation. You can find further information under Cross-reference
representation. If the Inherit From Parent Node option is active then
the settings will be copied from the parent project node.

Example Illustrates the effects of the settings using an example.

Reset Resets the settings to the settings defined in FluidSIM.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 263
Special functions for electric circuits

Chapter 16
16. Special functions for electric circuits

16.1 Potentials and conduction lines

The creation of horizontal and vertical potential lines is supported


by drawing conduction lines. The end points of the conduction line
consist of potentials that also serve as interruptions. In the dialog
window for drawing conduction lines you can specify whether the
potentials should have an identification.

In this example we want to draw three horizontal potential lines


where each line comes from a preceding sheet 1 and is continued
on a sheet 3.

You open a dialog window where you can make the settings shown
using the Insert Conduction Line... menu item or the button
on the toolbar.

264 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 16/1: Settings for the potential lines to be created

You can then define the end points of the line with two consecutive
mouse clicks.

Figure 16/2: Three horizontal potential lines

The identifications of the potentials can be changed. In this exam-


ple we want to rename the potential from L4 to L6.

Double-click the left-hand potential L1. Then enter L4 for the


identification in the dialog window.

Then following prompt then opens.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 265
Figure 16/3:

FluidSIM supports the automatic renaming of the potentials linked


with the source potential. If you answer Yes, the potential L1 on
the right-hand side will also be renamed L4.

Rename the potentials L2 and L3 to L5 and L6 in the same way.

Then enter the corresponding markers for the predecessors or


successors in the properties dialog windows for the potentials.
If the corresponding cross-references have the same markers in
the respective predecessor and successor pages, the potential
lines might look as follows.

Figure 16/4: Three horizontal potential lines with cross-references

16.2 Cables and wiring

Cables and wiring are represented in the circuit diagram by a spe-


cial cable symbol. All of the lines defined by the cable symbol are
assigned to a cable or to wiring. You can define for the symbol
whether it is a cable or wiring.

Wiring only summarizes the defined lines (wires) graphically in the


circuit diagram and is assigned the identification W by default.
Wiring is not listed in analyses such as cable maps and cable lists.
Unlike a cable, wiring cannot be assigned to a product. With wiring,
product information can only be saved in the lines.

266 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
If the cable symbol represents a cable then a cable object must be
assigned to the symbol. Product properties can be saved in the
cable object and are analyzed in cable maps and cable lists, etc.
Several cable symbols can reference the same cable object. This is
the case if, for example, a cable has to be spread over several
pages.

Figure 16/5: Cable symbol

Select the Cable menu item from the Insert menu or click
the button to define a cable or wiring.

This activates a mode that allows you to insert a cable symbol by


making two consecutive clicks. All of the lines that are defined by
the cable symbol are initially assigned to wiring.

If you want to use a cable instead of wiring you can assign a cable
object to the symbol using the properties dialog window for the
cable symbol.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 267
Figure 16/6: Cable Symbol dialog window, Wires tab

Layer Defines the drawing layer for the cable symbol.

Cable Wiring Defines whether the cable symbol represents a cable or wiring
comprising single wires. Wiring is not listed in cable maps, etc. If
Wiring is selected then an identification can be specified that can
be displayed with Display Identification.

If Cable is selected then an existing cable object can be assigned to


the cable symbol using a drop-down list. A new cable object can be
created using the Create New... button. Clicking Properties...
opens the properties dialog window for the selected cable object.

Wires In order to analyze cable maps the component connections that join
a wire must be determined. The connectors are automatically
entered in the list box if they can be uniquely assigned. If a unique
assignment is not possible, the relevant connector must be select-
ed manually via the list box. The identification for the individual

268 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
wires can also be entered. These are saved in the individual lines
(wires). The wire identifications are displayed at the cable symbol
using the Display button.

Reverse Direction The entries in the From and To column are automatically defined as
the direction of the wires when creating the cable symbol. Clicking
the Reverse Direction button reverses the directions of all of the
wires.

Renumber From: Clicking this button renumbers all of the wires defined by the cable
symbol, starting with the number entered in the list box.

Figure 16/7: Cable Symbol dialog window, Display Attributes tab

In the Display Attributes tab you can select the attributes of the
associated cable object that are to be displayed at the cable sym-
bol.

Click the Create New... button to create a new cable symbol.

The following dialog window opens.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 269
Figure 16/8: New Cable dialog window

Containing Page Indicates the page where the cable object will be saved. This is
important if various cable symbols on different pages reference the
same cable object. The cable object is only saved with one page.

Identification Enter the identification for the cable here.

Number of Wires Enter the number of lines (wires) in the cable here. The number can
be higher than the underlying lines if, for example, a concrete cable
has unconnected wires. If the associated cable symbols overscore
more lines than are defined in the cable object, a warning is output
when the page is checked and the corresponding entries are high-
lighted in color in the cable lists.

After you specify the identification for the cable and confirm the
dialog, the cable object is generated and the cable symbol is as-
signed to it.

Click the Properties... button to edit the properties of the


cable object.

270 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 16/9: Properties dialog window: Cable tab

Number of Wires Defines the number of lines (wires) in the cable. The number can be
higher than the lines overscored by the associated cable symbols if,
for example, a concrete cable has unconnected wires. If the associ-
ated cable symbols overscore more lines than are defined in the
cable object, a warning is output when the page is checked and the
corresponding entries are highlighted in color in the cable lists.

The associated cable symbols are listed in rows in the table. You
can jump to the associated cable symbol using the Find...
button.

The User Defined Properties tab in the properties dialog window for
the cable symbol lists the cable-specific product properties such as
Cable Type and Length. These properties and the entries in the
Cable tab are analyzed in the cable map, etc.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 271
16.2.1 Manage cables

All cables within a circuit can be listed and renamed using the
Manage Cables... menu item from the Page menu. You open the
properties dialog window for the relevant cable object using the
Properties... button.

You can also call up the cables of all circuits belonging to the pro-
ject using the Manage Cables... menu item from the Project
menu.

Figure 16/10: Manage Cables... dialog window

Containing Page Shows which circuit the cable is assigned to. You can edit this
assignment within a project.

You can add a new cable object to the project using the Create
New... button. Each cable object must be assigned to a page.

272 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Clicking the Create New... button first opens the following dialog
window where you can define the assignment.

Figure 16/11: Browse Pages dialog window

After you click the Select button a dialog window opens where
you can define the name and number of wires for the new cable
object. The dialog window is described under Cables and wiring.

16.2.2 Insert cable map

You can insert an associated cable map for a cable into the circuit
diagram. You do this by inserting a cable map into a circuit diagram
and then assigning a cable to this map.

To insert a cable map into the circuit diagram select the Cable
Map menu item from the Insert menu. Alternatively you can

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 273
click the button. Select Cable Map in the selection dialog
window that opens.

The mouse pointer changes to a crosshair. Click the position in the


circuit diagram where you want to insert the cable map. A dialog
window then opens where you can assign the relevant cable and
customize the appearance.

Figure 16/12: Cable Map dialog window

Cable Defines the relevant cable.

Properties... Opens the properties dialog window for the associated cable sym-
bol.

274 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
You can customize the appearance of the cable map in the Ap-
pearance tab. You can see the effects of the settings straight away
in the preview on the right-hand side.

If the Lines per Page option is selected you can specify the num-
ber of lines to be displayed per page. The relevant pages will also
be output when the circuit diagram is printed. Buttons for naviga-
tion are displayed underneath the page if the list is split across
multiple pages.

Figure 16/13: Buttons for navigating through lists

16.2.3 Insert cable list

You can insert a cable list into a circuit diagram.

To insert a cable list into the circuit diagram select the Cable
List menu item from the Insert menu. Alternatively you can
click the button. Select Cable List in the selection dialog
window that opens.

The mouse pointer changes to a crosshair. Click the position in the


circuit diagram where you want to insert the cable list. A dialog
window then opens where you can select the associated cable and
customize the appearance.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 275
Figure 16/14: Cable List dialog window, Included Pages tab

Include This Pages Compo- Lists only the cables in the associated circuit.
nents Only
Include All Project Files Lists all cables in the active project.

Include Selected Files: Lists all cables in the selected circuit in the active project.

276 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 16/15: Cable List dialog window, Appearance tab

You can customize the appearance of the cable map in the Ap-
pearance tab. You can see the effects of the settings straight away
in the preview on the right-hand side.

If the cable symbols of a cable object overscore more lines than are
defined in the cable object, a warning is output when the page is
checked and the corresponding entries are highlighted in color in
the cable list.

If the Lines per Page option is selected you can specify the num-
ber of lines to be displayed per page. The relevant pages will also
be output when the circuit diagram is printed. Buttons for naviga-
tion are displayed underneath the page if the list is split across
multiple pages.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 277
Figure 16/16: Buttons for navigating through lists

16.2.4 Insert wiring list

You can insert a wiring list into a circuit diagram.

To insert a wiring list into the circuit diagram select the Wir-
ing List menu item from the Insert menu. Alternatively you
can click the button. Select Wiring List in the selection di-
alog window that opens.

The mouse pointer changes to a crosshair. Click the position in the


circuit diagram where you want to insert the wiring list. A dialog
window then opens where you can select the associated wiring and
customize the appearance.

278 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 16/17: Wiring List dialog window, Included Pages tab

Include This Pages Compo- Lists only the wirings in the associated circuit.
nents Only
Include All Project Files Lists all wirings in the active project.

Include Selected Files: Lists all wirings in the selected circuit in the active project.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 279
Figure 16/18: Wiring List dialog window, Appearance tab

You can customize the appearance of the wiring list in the Appear-
ance tab. You can see the effects of the settings straight away in
the preview on the right-hand side.

If the Lines per Page option is selected you can specify the num-
ber of lines to be displayed per page. The relevant pages will also
be output when the circuit diagram is printed. Buttons for naviga-
tion are displayed underneath the page if the list is split across
multiple pages.

280 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 16/19: Buttons for navigating through lists

16.3 Terminals and terminal strips

16.3.1 Set terminals

You can set individual terminals or multiple terminals in one step.

Select the Terminal menu item from the Insert menu or


click the button to define an individual electric terminal.

This activates a mode that allows you to insert a terminal by click-


ing a free point on the electric line.

Figure 16/20:

As soon as you have set a new terminal in this way the dialog
window containing the settings for this terminal appears. You can
use this dialog window to assign the terminal to a terminal strip.
This assignment can also be made or changed later.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 281
Figure 16/21: Terminal dialog window

Description Contains the description of the terminal or the terminal designa-


tion.

Display If this box is checked then the description entered will be displayed
beside the terminal.

Layer Defines the drawing layer for the line.

Pos. Defines the position of the terminal within the associated terminal
strip. An entry is only possible once the terminal has been assigned
to a terminal strip.

Internal # External Changes the direction of the terminal. The direction is indicated in
the circuit by an arrow that shows which connector is inside the
control cabinet and which is outside. The tip of the arrow points
into the control cabinet.

Show Direction If this box is checked then the direction arrow is displayed at the
terminal.

Terminal Strip Defines the terminal strip containing the terminal in question. The
list contains the terminal strips already created. You call up the
properties dialog window for the selected terminal strip using

282 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Properties... . You can also create a new terminal strip using
Create New... .

Display Identification If this box is checked then the identification for the associated
terminal strip is displayed beside the terminal.

16.3.2 Set multiple terminals

As well as the option of setting individual terminals, FluidSIM also


offers a mode that allows you to set multiple terminals one after
the other. You can keep inserting terminals by simply clicking on
the electric lines until you leave the mode again.

To insert multiple terminals select the Multiple Terminals...


menu item from the Insert menu or click the button.

Figure 16/22:

The operation begins with a dialog window where you can make
some settings for the new terminals. Above all you need to first
select an existing terminal strip or create a new one. If a suitable

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 283
terminal strip does not already exist then a prompt to create a new
one will automatically appear.

Figure 16/23: Define Multiple Terminals dialog window

Description Defines how the new terminals are to be numbered. The Enumerate
Manually option allows you to specify a start number from which
the numbering continues. Otherwise a free terminal from the se-
lected terminal strip is automatically used. The start number 2
was specified in the example shown.

Display If this box is checked then the description entered will be displayed
beside the terminal.

Direction Defines the direction of the new terminals. The direction is indicat-
ed in the circuit by an arrow that shows which connector is inside
the control cabinet and which is outside. The tip of the arrow points
into the control cabinet. The direction can also be changed later
using the properties dialog window for the individual terminals.

Layer Defines the drawing layer for the line.

Terminal Strip Defines the terminal strip containing the terminals in question. The
list contains the terminal strips already created. You call up the
properties dialog window for the selected terminal strip using

284 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Properties... . You can also create a new terminal strip using
Create New... .

Display Identification If this box is checked then the identification for the associated
terminal strip is displayed beside the new terminals.

16.3.3 Create terminal strips

FluidSIM does not treat terminal strips as visible objects within the
circuit pages which explains why they cannot be interactively
selected using the mouse in order to highlight them, delete them or
change their properties. Terminal strips can either be managed via
the associated terminals or using the Manage Terminal Strips...
menu item under Page or Project .

A terminal strip is always part of a specific circuit. To define a new


terminal strip you must therefore define a circuit file in addition to
the description and number of terminals.

Figure 16/24: New Terminal Strip dialog window

All properties can also be changed later at any time. You open the
properties dialog window for a terminal strip via any terminal in
that terminal strip using the Properties... button.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 285
Figure 16/25: Terminal Strip dialog window

External Target If the target of a terminal inside the control cabinet is unique due to
the wiring, FluidSIM automatically enters the identification for the
connected component. Otherwise the list contains the identifica-
tions of all objects that can be reached from the terminal. The
target search can be controlled by selecting a junction symbol as a
T distributor.

Internal Target The targets of the terminals outside the control cabinet are listed
here. As with the internal targets, unique links are automatically
entered.

Find... Jumps to the associated terminal in the circuit diagram.

16.3.4 Manage terminal strips

All terminal strips within a circuit can be listed and renamed using
the Manage Terminal Strips... menu item from the Page menu.
You open the properties dialog window for the relevant terminal
strip using the Properties... button.

286 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
You can also call up the cables of all terminal strips belonging to
the project using the Manage Terminal Strips... menu item from
the Project menu.

Figure 16/26: Manage Terminal Strips... dialog window

Containing Page Shows which circuit the terminal strip is assigned to. You can edit
this assignment within a project.

You can add a new terminal strip to the project using the Create
New... button. Each terminal strip must be assigned to a page.
Clicking the Create New... button first opens the following dialog
window where you can define the assignment.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 287
Figure 16/27: Browse Pages dialog window

After you click the Select button a dialog window opens where
you can define the properties of the new terminal strip. The dialog
window is described under Create terminal strips.

16.4 Terminal diagram

You can insert an associated terminal diagram for a terminal strip


into the circuit diagram. You do this by inserting a terminal diagram
into a circuit diagram and then assigning a terminal strip to this
diagram.

Select the Terminal diagram menu item from the Insert


menu or click the button to insert a terminal diagram into
the circuit diagram. Alternatively you can click the button.
Select Terminal diagram in the selection dialog window that
opens.

288 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
The mouse pointer changes to a crosshair. Click the position in the
circuit diagram where you want to insert the terminal diagram. A
dialog window then opens where you can assign the relevant
terminal strip and customize the appearance.

Figure 16/28: Terminal diagram - Properties dialog window

Terminal Strip Defines the associated terminal strip.

Properties... Opens the properties dialog window for the associated terminal
strip.

You can customize the appearance of the terminal diagram in the


Print Options tab. You can see the effects of the settings straight
away in the preview on the right-hand side.

If the Lines per Page option is selected you can specify the num-
ber of lines to be displayed per page. The relevant pages will also

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 289
be output when the circuit diagram is printed. Buttons for naviga-
tion are displayed underneath the page if the list is split across
multiple pages.

The entries in the Description, Identification and Connector


columns are taken from the object properties of the associated
targets.

16.4.1 Set links

You can set so-called links in a terminal strip. These links are drawn
in the circuit diagram as regular electric lines and marked as links.
The representation of the T distributors can be customized using
their properties dialog window.

The following example shows a circuit diagram with a terminal strip


X1 with 10 terminals and the associated terminal diagram. A link
plug is to be placed at level 1 between terminals 7 and 8 and
at level 2 between terminals 8 and 9, and a wire link is to be
placed between terminals 9 and 10.

290 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 16/29:

Double-click the electric line between terminals 7 and 8.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 291
Figure 16/30:

The properties dialog window for the electric line opens. The op-
tions for setting the links are in the top right:

Figure 16/31: Detail of the Line (electric) dialog window

Link Defines that this line is to be treated as a link.

Link Plug Defines that the link is a link plug.

Level Specifies the level if a link plug was selected.

Wire Link Defines that the link is a wire link.

Set Link, Link Plug and Level 3.

FluidSIM tracks the line across one distributor point at most. This
means that the specified link will find the contacts 7 and 8. This
link will be represented in the terminal diagram as follows.

292 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 16/32:

Proceed in the same way to set a link plug between 8 and


9 at level 2 and a wire link between 9 and 10.

The terminal diagram then has the following appearance.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 293
Figure 16/33:

16.5 Contact images

The contact images can be displayed within a circuit diagram be-


neath relay coils and similar symbols. The contact images list all the
contacts of the associated relay coil and show which current paths
these contacts are in. The division of the page or circuit diagram
can be defined using the page dividers.

To do this select the Display Contact Images menu item from


the View menu.

The contact images of the current circuit diagram are shown or


hidden.

Contact images can be highlighted, moved and aligned like other


symbols.

294 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 16/34:

You can have all of the contacts in a contact image displayed in a


list and customize the appearance by double-clicking the contact
image or highlighting the contact image and selecting the Proper-
ties... menu item from the Edit menu.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 295
Figure 16/35: Contact Image dialog window

You can customize the representation of the contact image in the


Print Options tab.

The Contacts tab lists all of the associated contacts. You can
jump to the corresponding contact in the circuit diagram using the
Jump to Target button.

296 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Circuit input and output

Chapter 17
17. Circuit input and output

17.1 Print circuit diagram and parts list

FluidSIM circuits and parts lists can be printed by opening the Print
dialog window via the Print... menu item on the File menu.

In FluidSIM a parts list is the representation of a circuit as a table. If


you wish to print an individual parts list then the corresponding
circuit must be shown in the parts list display.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 297
Figure 17/1: Print dialog window:

Printer Select the desired output device from the list of the available print-
ers.

Properties... This button enables you to open the dialog window for setting the
printer options.

Print to File Activate this option if you wish to write the print data to a file.

Print Project Files When you work in a project you can select which circuits and parts
lists are to be printed.

Copies

298 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Select the number of copies. If the printout consists of multiple
pages you can cause FluidSIM to print a correspondingly sorted
sequence.

Scale You can increase or decrease the output size by entering a scaling
factor. If the dimensions of the area to be printed are larger than
the printable area on the paper then the printout is spread across
multiple pages (tiled). You can see the page divisions in the print
preview.

Note: Please note that it may not always be possible to precisely


comply with the page margins. Therefore you should plan a certain
amount of leeway for the page margin.

Page Here you can specify additional margins in order to manually cus-
tomize the print area.

Margins You can select which page the print preview displays.

17.2 Import DXF file

Files saved in the DXF format can be imported and retain most of
their element attributes. If several special points were taken into
account when creating the drawing using a CAD program then
FluidSIM can easily expand the symbol library.

17.3 Export circuit

The FluidSIM circuits can be saved as a file with a variety of differ-


ent formats. The BMP, JPG, GIF, WMF, PNG, DXF, TIF and PDF for-
mats are available. Once you have selected the Export... menu
item from the File menu a dialog window opens where you can
define the different settings for the export. The settings depend on
the format selected.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 299
Figure 17/2: Export Page dialog window

You are then prompted to select a file name or enter a new one.

Select a suitable resolution for the image file.

Please note that a high resolution generates extremely large files


which mean the export may take longer. However you can cancel
the image export at any time.

300 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Options

Chapter 18
18. Options

You can access the various program settings in the Options dialog
window via the Options... menu item on the Tools menu.

18.1 General

Figure 18/1: Options dialog window: General tab

View In order to simplify connection of connectors FluidSIM draws a


small circle around the connectors on the circuit symbols. Deacti-
vate the Display Snap Radius option in order to disable the display
of the snap-in circles.

Frame fluidic identification Activate the Frame fluidic identification option if you want fluidic
identifications to be framed automatically. This simplifies the
depiction of circuits in accordance with standards.

Frame Electric Identification Activate the Frame Electric Identification option if you want electri-
cal identifications to be framed automatically. This simplifies the
depiction of circuits in accordance with standards.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 301
Zoom Here you can set how you can zoom in or out of the page view with
the mouse.

Display initially actuated When this option is activated, make switches that are actuated in
closer as opener their initial position are displayed as break switches. Conversely,
break switches that are actuated in their initial position are dis-
played as make switches.

Grid Here you can set the grid width and the style. To display the grid,
select the Show Grid menu item on the View menu.

As well as absolute values such as mm you can also specify the


relative basic unit length M.

18.2 Save

Figure 18/2: Options dialog window: Save tab

Compress Files FluidSIM normally compresses the saved files in order to save
space on the disk. If you deactivate the option the files are saved as
XML files without compression. You can find further information in
the Circuit files section.

302 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Create Backup Files The Create Backup Files option causes the previous versions of
saved files are created with the bak file suffix. This enables you to
restore previous versions.

Save New Projects as Single Project files generally consist of links to the files contained therein.
File However, where desired FluidSIM can also save the project along
with all of the associated circuit files in one single file. This serves
to simplify passing on or archiving the project, among other things.
You can set whether a project saves links or all of the associated
files using the Project dialog window Properties of the project.
This option defines the default setting for new projects.

Create Folder For New Pro- A folder with the project name where all project files are stored is
jects automatically generated when a new project is created if this op-
tion is active.

18.3 Folder Locations

Figure 18/3: Options dialog window: Folder Locations tab

Page Files This is the default path for opening and saving circuits.

Project Files This is the default path for opening and saving projects.

Library Files This is the default path for opening and saving libraries.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 303
Drawing Frames This is the default path for opening and saving drawing frames.

18.4 Language

Figure 18/4: Options dialog window: Language tab

Program Defines the languages for the program interface including dialog
windows and messages.

18.5 Dimension

This tab is used to define the default settings for the dimensions.
You can find further information under Dimension.

304 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 18/5: Options dialog window: Dimension tab

All of the settings are only applied to newly generated dimensions.


They have no effect on existing dimensions in the circuit.

Layer Defines the drawing layer where the newly generated dimensions
are placed.

Automatic Dimensioning Activates and deactivates automatic dimensioning. If this option is


activated then the displayed dimension value is automatically
adapted if the dimension is scaled.

Unit Defines the unit to be used for the dimension.

Show Unit Defines whether the unit should be displayed.

Decimals Defines the number of decimal places.

Scale Factor Determines the factor by which the real length is multiplied for the
displayed value. This is necessary if you are creating a drawing with
a scale other than 1:1.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 305
18.6 Cross Reference Representation

Figure 18/6: Options dialog window: Cross Reference Representa-


tion tab

This tab is used to define the default settings for the cross-
reference representation. You can find further information under
Cross-reference representation.

The settings are only applied to newly generated projects or cir-


cuits. They have no effect on existing objects.

Example Illustrates the effects of the settings using an example.

Reset Resets the settings to the settings defined in FluidSIM.

306 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
18.7 Connector Links

Figure 18/7: Options dialog window: Connector Links tab

Allow connections between Only connectors of the same type can be connected if this option is
same connector types only active. For example a line from an electric connector to a pneumatic
connector cannot be created in this case.

FluidSIM supports the automatic connection of connectors. The


following settings define which connections should be automatical-
ly created.

Pneumatic Horizontal Pneumatic connectors that are on one horizontal line will be auto-
matically connected when a symbol is inserted or moved.

Pneumatic Vertical Pneumatic connectors that are on one vertical line will be automati-
cally connected when a symbol is inserted or moved.

Electric Horizontal Electric connectors that are on one horizontal line will be automati-
cally connected when a symbol is inserted or moved.

Electric Vertical Electric connectors that are on one vertical line will be automatical-
ly connected when a symbol is inserted or moved.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 307
18.8 Warnings

Figure 18/8: Options dialog window: Warnings tab

Show Warnings Different types of warnings that FluidSIM should or should not
deliver can be activated and deactivated here. These warnings
include Duplicated identification labels and Superimposed
objects.

Enable Background Check All of the circuits will be checked during editing if this option is
active. Only the criteria that would lead to the warnings specified
under Show Warnings are checked. Objects that caused an error
are highlighted in red in the circuit. If this option is not active then
the check must be initiated manually using the Page Check
Drawing menu.

308 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
18.9 Automatic Updates

Figure 18/9: Options dialog window: Automatic Updates tab

Check for updates at startup FluidSIM can search on the Internet for a new version when the
program starts. You can activate or deactivate the automatic search
here.

Check for updates now... As soon as there is an Internet connection you can use this button
to initiate the search for a new FluidSIM version.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 309
18.10 Simulation

Figure 18/10: Options dialog window: Simulation tab

Display interval Normally FluidSIM calculates all data required for the simulation
automatically, without bothering the user with mathematical de-
tails. However, in some cases it can be useful to specify a certain
increment, for example, in order to achieve a more accurate display
of high frequencies in electronics. For instance, if you want a reso-
lution in the microsecond range, enter an increment of at least
0.000001 (or in scientific notation 1e-6).

Note that simulation in real time is no longer possible if the incre-


ments are very small.

Slow-motion factor You can use this factor to set the ratio of time in which the simulat-
ed processes should take place. A value of 1:1 means simulation
in real time; 1:10 would mean that the simulation takes place in
slow motion, in this case ten times slower than in reality. A ratio of
1:0.1, for example, would mean the simulation is accelerated ten
times. Specifications for real time or accelerated processes can only
be fulfilled if the computer has sufficient processing power.

310 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Line colors During the simulation, the pneumatic, hydraulic, electrical, and
digital lines will be colored according to their state. You can cus-
tomize the colors for each state.

Digital Technique (Compati- In digital technology, it is useful if unused inputs on AND, NAND,
bility with Siemens and NOT components are automatically set to Hi. Otherwise, for
LOGO!Soft) example, an AND gate with three inputs would not function as
expected if only two inputs were wired. So that the circuit does not
become cluttered with unnecessary permanently Hi level signals,
FluidSIM can set unused inputs on the relevant components to Hi
automatically. If you do not want this automatic function, you can
switch it off. To prevent misunderstandings regarding unused
digital inputs, FluidSIM displays a corresponding message at the
start of every simulation. If you do not want this message to ap-
pear, you can switch it off.

Note that these values are only used if no others are defined in the
page or project properties.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 311
18.11 GRAFCET

Figure 18/11: Options dialog window: GRAFCET tab

GRAFCET mode Here you can set the mode that FluidSIM will apply when handling
GRAFCETs during the simulation.

GrafEdit (GRAFCET is not In this mode, GRAFCETs are treated as drawings only. They are not
simulated) incorporated into the simulation. See also Drawing only (GrafEdit).

GrafView (GRAFCET visual- This mode uses GRAFCETs for visual presentation of the simulation.
izes simulation) The defined actions, however, have no effect on the simulation. In
particular, they do not in any way control the fluidic or electrical
components. See also Observation (GrafView).

GrafControl (GRAFCET con- In this mode, the GRAFCET has access to all the circuit variables
trols simulation) that can be set from outside. This allows it to switch valves over or
to adjust throttle valves See also Control (GrafControl).

Enable monitoring When this option is switched on, the GRAFCET monitors the proper
functioning of a fluidic or electrical circuit. For this purpose, you can
formulate conditions in the actions which will be checked during
the simulation. For more details, see Monitoring with GRAFCET
actions.

312 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Note that these settings are only used if no others are defined in
the page or project properties.

18.12 DDE Connection

Figure 18/12: Options dialog window: DDE Connection tab

Here you can set the default values for the DDE interface.

Note that the server name is a global setting of the specific system
environment and is not saved with the circuit data. If you want to
use the DDE interface in other environments, ensure that the DDE
options are adapted accordingly. In particular, ensure that the DDE
connection is activated, because it is switched off by default for
security reasons.

18.13 Environment parameters

Figure 18/13: Options dialog window: Environment parameters tab

Here you can set the default values for the environment parame-
ters.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 313
Note that these values are only used if no others are defined in the
page or project properties.

18.14 Fluid properties

Figure 18/14: Options dialog window: Fluid properties tab

Fluid type This list contains typical oils and other fluids. If you select a prede-
fined fluid, the listed values will be set accordingly.

Note that these values are only used if no others are defined in the
page or project properties.

18.15 Sound

When you click the Sound tab in the Options... menu, a dialog
box appears with parameters for the sound settings:

314 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 18/15: Options dialog window: Sound tab

Enable sound You can activate/deactivate an audible signal for the components
Switch/Contact, Relay, Valve, Cylinder, and Buzzer.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 315
18.16 Text Sizes

Figure 18/16: Options dialog window: Text Sizes tab

This tab defines the font sizes to be used for objects newly inserted
into the circuit diagram.

Label/Attribute This group lists the font sizes used for identifications and cross-
references, etc.

List/Table This group lists the font sizes used for analyses and tables.

316 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Menu overview

Chapter 19
19. Menu overview

19.1 File

New

New / File...
Opens a new window for creating a new circuit drawing.

New / Project...
Opens the dialog window for creating a new project.

Open

Open / File...
Opens a new window for selecting an existing circuit drawing.

Open / Project...
Opens the dialog window for selecting an existing project.

Add
Adds files, etc. to the active project.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 317
Add / New Page...
Creates a new circuit file and adds it to the active project.

Add / New Parts List...


Creates a new parts list and adds it to the active project.

Add / Existing Files...


Opens the dialog window for selecting existing files to be added to
the active project.

Close
Closes the active window or project, etc.

Close / File...
Closes the active window.

Close / Project...
Closes the active project.

Save File
Saves the circuit diagram in the active window to disk.

Save File As...


Saves the circuit diagram in the active window to disk under a new
name.

Save Project
Saves the active project.

318 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Save Project As...
Saves the active project under a new name on the data storage
medium. Files that are within the project folder are duplicated while
references to external files are left. With external file references you
must therefore consider that changes to these files affect all pro-
jects containing them.

Save as Component Library...


Saves the active project as a library. As a result a new library sym-
bol is generated for every circuit. The new library bears the name of
the project with the lib file suffix.

DXF Import...
Opens the dialog window for selecting a saved DXF file. The select-
ed file is subsequently converted into a FluidSIM circuit diagram.
The original file remains unchanged.

Export...
Exports the circuit diagram in the active window to the data storage
medium as a BMP, JPG, GIF, WMF, PNG, DXF or TIF file.

Page Setup...
Sets up the printer properties for a page to be printed.

Print Preview
Opens a print preview as a page view.

Print...
Opens the FluidSIM Print dialog window to set the print options for
the active circuit.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 319
Recent Files
A file can be selected for opening from a list of the recently opened
files.

Recent Projects
The most recently opened projects can be selected for opening
from a list.

Exit
Ends FluidSIM.

19.2 Edit

Undo
Undoes the last editing action for the active circuit.

Redo
Takes back the last undo-action for the active circuit.

Cut
Deletes the selected objects and adds them to the clipboard.

Copy
Copies the selected objects to the clipboard

Paste
Pastes the objects from the clipboard into the active circuit.

320 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Delete
Deletes the selected objects from the active circuit.

Select All
Selects all of the objects from the active circuit.

Group
Groups the selected objects.

Create Macro Object


Creates a macro object out of the selected objects.

Create Cross-reference
Creates a cross-reference.

Ungroup/Break Off
Ungroups the selected groups or macro objects.

Enable Scale
Activates or deactivates the enable scaling mode which enables
the scaling of symbols with the help of the mouse pointer.

Enable Rotate
Activates or deactivates the enable rotate mode which enables
the rotation of symbols with the help of the mouse pointer.

Edit Poly Line


Activates or deactivates the Edit Polyline mode that allows you to
edit a polyline.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 321
Align
Aligns the selected objects with each other.

Rotate
Rotates the selected objects by 90, 180 or 270 degrees anti-
clockwise. Grouped objects are rotated around the center point of
the group rectangle.

Mirror
Mirrors the selected objects horizontally or vertically. Grouped
objects are mirrored along the axis of the group rectangle.

Properties...
Opens the Properties dialog window for the selected circuit sym-
bols in order to enter the component properties.

The Connector dialog window is opened for the selected compo-


nent connector enabling you to enter the connector properties.

When a line segment is highlighted a dialog window opens ena-


bling you to enter the line properties.

If multiple objects are selected then a dialog window with a limited


selection of properties appears. It only contains those properties
which affect all of the selected objects.

19.3 Insert

Find Symbol Description...


Opens the search dialog for selecting a symbol via its appearance
or its description.

322 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Conduction Line...
Opens a dialog window that defines the settings for one or more
conduction lines that are to be inserted in the circuit diagram after
the dialog window is confirmed.

Interruption/Potential...
Adds an interruption or an electric potential to the circuit diagram.

Parts List
Inserts a parts list into the circuit diagram.

Terminal
Inserts a terminal into the circuit diagram.

Multiple Terminals...
Inserts multiple terminals into the circuit diagram.

Terminal diagram
Inserts a terminal diagram into the circuit diagram.

Cable
Inserts a cable into the circuit diagram.

Cable Map
Inserts a cable map into the circuit diagram.

Cable List
Inserts a cable list into the circuit diagram.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 323
Wiring List
Inserts a wiring list into the circuit diagram.

Tube List
Inserts a tube list into the circuit diagram.

19.4 Draw

This menu contains functions for freely drawing graphical elements


such as lines, rectangles, circles, etc as well as for inserting texts
and images.

Line
Draws a line by defining two defined end points.

Poly Line
Draws a polyline by defining the vertices with successive mouse
clicks. The drawing operation can be cancelled by pressing the
Esc key or clicking the right mouse button. The last vertex must
be set with a double-click.

Rectangle
Draws a rectangle by defining two diagonally opposite corner
points.

Circle
Draws a circle by defining a middle point and a radius.

324 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Ellipse
Draws an ellipse by defining a middle point and a radii on parallel
axes.

Text
Inserts a text at the mouse position.

Picture
Inserts an image at the mouse position.

Dimension
Inserts a dimension symbol.

19.5 Page

Check Drawing
Checks the active circuit drawing for drawing errors.

Paper Size...
Opens a dialog window enabling you to set the paper size.

Manage Terminal Strips...


Opens a dialog window enabling you to manage the terminal strips
in the circuit.

Manage Cables...
Opens a dialog window enabling you to manage the cable objects
in the circuit.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 325
Properties...
Opens an dialog window enabling you to set the circuit properties.

19.6 Execute

Stop
Switches the currently active circuit into Edit Mode.

Start
Starts the simulation (animation) in the currently active circuit.

Pause
Pauses the simulation in the currently active circuit without exiting
Simulation Mode.

If Pause is clicked when in Edit Mode, the currently active circuit


switches to Simulation Mode without starting the simulation. This
allows you to set component states before starting the simulation.

Reset
Resets a circuit to its initial state when a simulation is running or
paused. The simulation is then restarted immediately.

Single Step
Stops the simulation after a small step. In other words, the simula-
tion is started for a short period of time before being switched back
into pause mode ( ). You can switch into single step mode directly
from an actively running simulation.

326 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Simulate until State Change
Starts the simulation and runs it until a state change happens; the
simulation is then paused ( ). A state change happens when a
cylinder piston moves against a stop, a valve switches over, or a
relay or a switch is actuated. You can switch into state change
mode directly from an actively running simulation.

Next topic
Switches to the next topic in a presentation.

19.7 Didactics

Component description
Opens the help page for the selected component. It contains the
DIN symbol for the component, a short description of the compo-
nent function, the terminal designations, and a list of any adjusta-
ble parameters, with value ranges for those parameters.

Tutorial Simulating with FluidSIM'


Opens the tutorial Simulating with FluidSIM.

Component Library
Opens the reference containing information about the components
in the component library.

Didactics Material
Opens an overview of the didactics material. If you copied the film
files onto your hard disk during installation, the list of training film
chapters will also appear here.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 327
Circuits for exercises (TP)...
Opens a dialog box with exercise circuits for the Festo technology
packages.

Presentation...
Opens a dialog box that you can use to retrieve and create presen-
tations. Presentations allow you to combine separate training
topics into a cohesive teaching unit.

Extended Presentation...
Opens a dialog box that you can use to retrieve existing presenta-
tions in Microsoft PowerPoint format. The presentation files of the
extended presentations are located in the ppx subfolder of your
FluidSIM installation. You can create your own PowerPoint presen-
tations and add them by saving them in ppt or pps format to
the ppx folder.

19.8 Project

Add Current Window


Adds the active window to the file list of the open project.

Remove Current Window


Removes the active window from the file list of the open project.

Manage Terminal Strips...


Opens a dialog window enabling you to manage the terminal strips
in the project.

328 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Manage Cables...
Opens a dialog window enabling you to manage the cable objects
in the project.

Manage Cross References...


Opens a dialog window enabling you to manage the cross-
references in the project.

Properties...
Opens the dialog window for entering the project properties.

19.9 View

Circuit Diagram
Switches from the parts list view to the circuit diagram view.

Parts List
Switches to the parts list view.

Library
Shows or hides the libraries window.

Project
Shows or hides the window for managing the project files.

Standard Size
Displays the circuit diagram in its original size.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 329
Previous View
Displays the previous view of the circuit diagram. Repeatedly
activating this function switches back and forth between the views
previously used.

Fit to Window
Set the zoom level to fit the entire circuit diagram into the window.

View Detail
Defines the new view by drawing a rectangle while holding down
the left mouse button.

Zoom In
Zooms the view of the circuit diagram in by one step. Three steps
correspond approximately to doubling the zoom factor.

Zoom Out
Zooms the view of the circuit diagram out by one step. Three steps
correspond approximately to halving the zoom factor.

Show Page Borders


Shows or hides the page borders in the form of a red rectangle. This
rectangle displays the borders of the paper format defined on the
Paper Size... menu. Using the print preview you can decide
whether and how the drawing is distributed among multiple sheets
when printing.

Show Grid
Shows a background grid in the active circuit window. The grid
settings can be made in the General tab under the Options...
menu item from the Tools menu.

330 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Show Rulers
Shows or hides the rulers in the active circuit window.

Show Page Dividers


Shows or hides the page dividers in columns and rows. Cross-
references can refer to the column and row containing a symbol.
The position and number of the columns and rows can be interac-
tively defined via the page dividers shown.

Quantity Values...
Opens a dialog box for display of quantity values. Here you can
define how each quantity value listed (velocity, pressure,
current, ...) is to be displayed ( None , Individual , All ).

Show Flow Direction


When this option is active, small arrows are placed on pneumatic
and hydraulic lines as a visual indication of the flow direction.

Show Flow Animation


When this option is active, the flow in pneumatic and hydraulic
lines is made visible by animating the lines like conveyor belts.

GRAFCET...
Opens a dialog box for display of GRAFCET descriptions. Here you
can set whether to display the descriptions or the formulas of
GRAFCET elements. Note that this option may overwrite the specific
settings of individual elements.

Display Current Path Numbering


When this option is active, the current path designations are shown
in the electrical circuits. The division of the page or circuit diagram
can be defined using the page dividers.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 331
Show Connector Descriptions
Shows or hides the connector descriptions. The Display option can
be selected in the properties dialog window for the connectors. This
option is only evaluated if Individual was selected.

Show Connector Descriptions / All


Shows all connector descriptions regardless of the settings at the
connectors.

Show Connector Descriptions / Individual


Shows only the connector descriptions for those connectors with
the Display option activated.

Show Connector Descriptions / None


Hides all connector descriptions regardless of the settings at the
connectors.

Show Terminal Directions


Shows or hides the direction arrows at the terminals. The tip of the
arrow points into the control cabinet here.

Show Terminal Directions / All


Shows all arrows regardless of the settings at the terminals.

Show Terminal Directions / Individual


Shows only the arrows for those terminals with the Show Direction
option activated.

Show Terminal Directions / None


Hides all arrows regardless of the settings at the terminals.

332 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Display Contact Images
Shows or hides the contact images.

Drawing Layers...
Opens a Drawing Layers dialog window enabling you to set the
properties of the drawing layers.

19.10 Library

Add New Library...


Creates a new library.

Add Existing Library...


Opens the dialog window enabling you to select a saved library file
with the lib file suffix. The library saved in the file is added to the
library window.

Add Existing Symbol Folder...


Opens the dialog window for selecting an existing folder. The entire
contents of the selected folder, including all of the circuit symbols
and sub-folders contained therein are displayed as a library.

Close Current Library


Removes the active library from the list in the library window. The
library file is not deleted by this action and can be opened again
using the Library menu and the Add Existing Library... menu
item.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 333
Rename Active Library...
Opens a dialog window for entering the name of the library. This
function is only available to libraries which the user has created.
For write-protected libraries the folder name is shown in the tab.

Sort Current Library Alphabetically


Sorts the contents of the active library alphabetically. This function
is only available to libraries which the user has created. Write-
protected libraries are automatically sorted and cannot be resorted
by the user.

19.11 Tools

Options...
Opens the dialog window with program settings, file paths and
language options.

Expert Mode
Switches Expert Mode on and off. Expert Mode provides advanced
options for editing and simulation.

Restore Defaults...
Resets the program settings to the default values. This enables you
to undo unintentional settings made.

Note: Use this function if you feel that FluidSIM is behaving unex-
pectedly or files and windows have suddenly disappeared.

334 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
19.12 Window

New Window
Opens a window with an additional view of the active window.

Navigation Pane
Opens an overview window with a scaled-down view of the entire
circuit diagram. The currently visible area of the active window
appears as a white area. The non-visible area of the drawing is
shaded grey. By drawing a rectangle in the overview window with
the mouse pointer you can define the section of the circuit diagram
displayed in the active window. Simply left-clicking on the overview
window moves the visible area while retaining the zoom level.

Cascade
Arranges the windows so that they overlap.

Tile Horizontally
Arranges the windows into horizontal tiles.

Tile Vertically
Arranges the windows next to each other.

Close All
Closes all open windows.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 335
19.13 Help

Contents
Displays the contents of the FluidSIM help pages.

Index
Displays the index of the FluidSIM help pages.

Search
Displays the search dialog for the FluidSIM help pages.

Register as user...
Opens a dialog box via which you can register if you would like
assistance and information about FluidSIM.

Check for updates...


As soon as there is an Internet connection you can use this menu
item to initiate the search for a new FluidSIM version.

About...
Displays the FluidSIM program information.

336 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Functional diagram

Chapter 20
20. Functional diagra m

You can find the function diagram in the standard FluidSIM library.
You can apply the functions from the Edit menu to the function
diagram. Double-click the function diagram or open the Functional
diagram using the Properties... menu item on the Edit menu.

The buttons in the upper toolbar of the editor are for editing a
function diagram. The following six buttons determine the editing
mode:

Edit Mode

Draw diagram curves

Insert signal elements

Insert text boxes

Draw signal lines and insert signal connections

Insert additional signal lines

The selected mode is highlighted in white or displayed as a pressed


button. shows that signal lines can be drawn in the diagram
area by clicking, for example.

If you hover the mouse pointer over a button for a short period of
time then a short description is displayed.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 337
Figure 20/1:

20.1 Edit Mode

This mode serves to adjust the objects in the function diagram.


Elements in the diagram can be moved. Changing the size of text
boxes is only possible in this mode.

Movement and dragging operations can be cancelled using the


Esc key.

If the mouse pointer is moved outside the window area while the
left mouse button is held down the view automatically scrolls.

Double-clicking on a diagram element (diagram row, text box,


signaling element, etc.) opens a dialog window in which you can
make the desired adjustments.

20.1.1 Set diagram properties

Clicking on the button opens a dialog window in


which you can set the diagram properties.

338 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 20/2:

Text columns Number If the number of text columns is changed than all of the table text
boxes are distributed horizontally and evenly.

Text columns Width If the width of the text columns is changed than all of the table text
boxes are distributed horizontally and evenly.

Diagram columns Number The diagram columns are located on the right-hand side of the
function diagram. The diagram curves can be drawn in this area.
The number of diagram columns can also be changed by dragging
the mouse pointer to the right-hand edge of the diagram.

Diagram columns Width

Color The color which the grid lines are drawn in the diagram area.

Row height Defines the row height of all of the rows.

20.1.2 Table textboxes

The table textboxes are located on the left-hand side of the function
diagram.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 339
Figure 20/3:

Double-clicking on a table textbox opens the corresponding dialog


window.

Figure 20/4:

Font size The font size of the text to be shown.

Color A selection from sixteen standard colors for the text to be dis-
played.

Width The width of the selected table column can be changed by dragging
the mouse pointer.

Height The height of the selected table column can be changed by drag-
ging the mouse pointer.

Horizontal adjustment The following alignment options are available: Left Center and
Right.

Vertical adjustment The following alignment options are available: Top, Center and
Bottom

340 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Alignment within a table cell If a text within a textbox should resemble a table then set a tab stop
between the text parts. The text is displayed in the textbox in ac-
cordance with the number of tab stops and the specified horizontal
and vertical alignment. To enter tab stops hold down the Ctrl
key.

Examples:

1.

2.

Insert text boxes

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 341
20.1.3 Adjust the presentation of the diagrams

The area in which curves can be drawn is located on the right-hand


side of a diagram row.

Figure 20/5:

Double-clocking on this area opens a corresponding window in


which you can define the appearance of the drawing area. Please
ensure that no diagram element, such as a signaling element, for
example, is underneath the mouse pointer.

Figure 20/6:

States Number The entry defines the number of states and thus the number of
horizontal lines in the diagram row.

342 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
States Base state Horizontal lines are drawn through the base state with a thin pencil.

Numbering Start column The start column defines which column the numbering should
begin with.

Numbering Start number The start number defines which number the numbering should
begin with.

Numbering Number The number specified how many steps need to be numbered.

Numbering Step width Defines the step width between two numbers.

Numbering Loop If this field is selected then an equals sign and the start number are
always displayed after the last number.

Representation Display If this field is selected then two arrows are displayed.
arrows
Representation Display grid If this field is selected then the background grid is displayed.

Representation Display text If this field is selected then a textbox is shown which can serve as a
1 label. This textbox belongs to the selected row and cannot be
moved to another row.

Representation Display text If this field is selected then an additional textbox is shown which
2 can serve as a label. This textbox belongs to the selected row and
cannot be moved to another row.

Representation Line color Sets the color of the diagram lines.

20.2 Draw diagram curve

In this mode diagram curves can be drawn. Supporting points


can only be inserted on the grid. A supporting point is drawn at
every left-click.

1. 2. 3. 4.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 343
If you hold down the left mouse button then supporting points can
be moved as in the selection mode.

Selected supporting points are shown in grey. Use the Del key to
delete a selected symbol.

20.3 Insert signal elements

In this mode signaling elements can be inserted by left-clicking.

1. 2.

If you hold down the left mouse button then signaling elements can
be moved as in the selection mode.

Selected signaling elements are shown in grey. Use the Del key
to delete a selected signaling element.

Double-clicking on a signaling element in the selection mode opens


a dialog window in which you can modify how the signaling element
is shown.

344 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 20/7:

Signal type

Display description If this field is selected then a text is shown which can serve as a
label for the signaling element.

Color The signaling element is displayed in this color.

20.4 Insert text boxes

In this mode textboxes can be inserted by left-clicking.

1. 2. 3.

Selected textboxes are shown in grey. Use the Del key to delete
a selected textbox.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 345
In Edit Mode the size and position of a textbox can be changed
using the mouse pointer.

Adjust size:

1. 2. 3.

Move textbox:

1. 2. 3.

Double-clicking on a textbox in the selection mode opens a dialog


window in which you can modify how the textbox is shown.

Figure 20/8:

Font size The font size of the text to be shown.

346 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Color A selection from sixteen standard colors for the text to be dis-
played.

Frame If this field is selected then a frame is drawn around the textbox.

Width The width of the textbox.

Height The height of the textbox.

Horizontal adjustment The following alignment options are available: Left, Center and
Right.

Vertical adjustment The following alignment options are available: Top, Center and
Bottom

Table textboxes

20.5 Draw signal lines and insert signal connections

In this mode signal lines can be drawn freely or automatically


laid from signaling elements.

20.5.1 Free-draw signal lines

An additional supporting point is set with every left-click. The


process ends when you click the current line while holding down
the Ctrl key, press the Esc key or switch the editing mode. Use
the Del key to delete a selected signal line. If only a supporting
point is selected then only this is removed from the line.

In Edit Mode the supporting points belonging to the signal lines


can be moved. If the Shift is held down while setting or moving

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 347
supporting points then the supporting point is vertically or horizon-
tally aligned.

In the selection mode double-clicking can change the way the line
is displayed.

Figure 20/9:

Display description A framed label on the line and a label next to the framed label is
shown. The framed label can be moved freely along the line. The
additional label can be moved freely.

Start with arrow An arrow is displayed at the beginning of the line. The arrow can be
moved freely along the line.

End with arrow An arrow is displayed at the end of the line. The arrow can be
moved freely along the line.

Color Line color

If you click a finished signal line to activate the Freely move signal
lines mode then a signal logic is inserted. This logic point
(snap point) can then be freely moved along the line 1.

2. 3. + 4. .

In the selection mode you can change how the signal logic is dis-
played by double-clicking on it.

348 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 20/10:

20.5.2 Drawing signal lines from signals

In the Freely draw signal lines signal lines can be drawn from
signals. Left-click a signal and hold down the mouse button. Drag
the mouse pointer to a position which you have selected as the end
point of a signal line. The signal line will be drawn once you release
the mouse button.

1. 2. 3.

20.5.3 Draw signal lines from diagram support points

In the Freely draw signal lines mode signal lines can be


drawn from curve support points. Left-click a supporting point and
hold down the mouse button. Drag the mouse pointer to a second
supporting point. The signal line will be drawn once you have the

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 349
mouse pointer over the second supporting point and release the
mouse button.

1. 2. 3.

20.6 Insert additional signal lines

In the Insert additional signal lines mode additional support-


ing points can be inserted into existing signal lines.

1. 2. 3.

20.7 Insert row

Clicking on the Insert row button inserts a new diagram row


above the current selection. If no cell is market then a new row is
attached to the end of the diagram.

20.8 Delete row

Clicking on the Delete row button deletes a selected diagram


row. If nothing is selected then the function is not available.

350 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
20.9 Additional editing functions

20.9.1 Zoom

Using the button the view is reset to the standard zoom level.

Using the button increases the zoom level.

Using the button decreases the zoom level.

20.9.2 Undo editing steps

Using the button you can undo the last 50 editing steps.

Using the button you can redo the previously undone editing
steps.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 351
The Component Library

Chapter 21
21. The Component Library

In FluidSIM each component in the component library is assigned a


physical model. Using these models, FluidSIM first creates a global
behavior model of the circuit which is then processed during simu-
lation.

This chapter provides for a short description of the components in


FluidSIM s component library. If the component has adjustable
parameters, their value ranges are given. A number in brackets
after the value range indicates the default setting for the parame-
ter.

21.1 Hydraulic Components

21.1.1 Service Components

Pump unit

The pump unit supplies a constant volumetric flow. The operating


pressure is limited by the internal pressure relief valve. The pump
unit has two tank connections.

Adjustable parameters
Opening pressure: 0 ... 40 MPa (6)
Revolution: 0 ... 5000 1/min (1450)
Displacement: 0.1 ... 5000 cm3 (1.6)
Internal leakage: 0 ... 10 l/(min.bar) (0.002)

352 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Pump unit (simplified)

Simplified representation of the detailed pump unit. The compo-


nent does not have tank connections in the circuit diagram.

Adjustable parameters
Delivery rate: 0 ... 500 l/min (2)
Maximum pressure: 0 ... 40 MPa (6)
Internal leakage: 0 ... 10 l/(min.bar) (0)

Fixed displacement pump

The fixed displacement pump delivers a constant volumetric flow


rate dependent upon the revolutions and the displacement volume.

Adjustable parameters
Revolution: 0 ... 5000 1/min (1320)
Displacement: 0.1 ... 10000 cm3 (1.6)
Maximum pressure: 0.1 ... 40 MPa (6)
Internal leakage: 0 ... 10 l/(min.bar) (0)

Variable displacement pump

The revolutions of the variable displacement pump can be changed


under operating conditions. The pump delivers a variable volumet-
ric flow rate dependent upon the variable revolutions and the
displacement volume.

Adjustable parameters
Revolution: 0 ... 5000 1/min (1320)
Displacement: 0.1 ... 10000 cm3 (1.6)
Flow rate ratio: 0 ... 100 % (100)
Maximum pressure: 0.01 ... 40 MPa (6)
Internal leakage: 0 ... 10 l/(min.bar) (0)

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 353
Proportional pump

The revolutions of the variable displacement pump can be changed


proportionally from zero to maximum through a voltage signal
between 0 V and 10 V and the assistance of a proportional-
amplifier. The pump delivers a variable volumetric flow rate de-
pendent upon the variable revolutions and the displacement vol-
ume.

Adjustable parameters
Mode of control: Displacement control, Speed control (Displace-
ment control)
Displacement: 0.1 ... 5000 cm3 (1.6)
Revolution (min): 0 ... 5000 1/min (0)
Revolution (max): 0 ... 5000 1/min (1320)
Flow rate ratio (min): 0 ... 1 (0)
Flow rate ratio (max): 0 ... 1 (1)
Maximum pressure: 0.01 ... 40 MPa (6)
Internal leakage: 0 ... 10 l/(min.bar) (0)

Power pack with LS variable and fixed displacement pump combi-


nation on a single motor

The hydraulic power pack is suitable for all basic tests of mobile
hydraulics. The two pumps are both driven by one electric motor.
The vane pump with adjustable delivery rate has a load sensing
pump controller. The fixed displacement pump is secured by a
pressure relief valve. The pump/motor unit sits on the tank. The
return into the tank passes through a return flow filter. The ventila-
tion of the tank is also filtered. The oil level can be seen on the
sight glass with temperature display. The motor is switched on and
off from a control console and is safeguarded against overloading.

Adjustable parameters
Revolution: 0 ... 5000 1/min (910)
Displacement (Variable displacement pump): 0 ... 10000 cm3
(5.6044)
Opening pressure (Variable displacement pump): 0 ... 40 MPa (5)

354 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Spring preload: 0.1 ... 10 MPa (1.17)
Displacement (Fixed displacement pump): 0 ... 10000 cm3
(4.5055)
Opening pressure (Fixed displacement pump): 0 ... 40 MPa (5)

Steering unit (Orbitrol)

The steering unit is used to steer vehicles that are equipped with
hydrostatic steering.

The steering unit consists of a proportional rotary valve, a pump


control valve and a dosing pump. The rotary valve is opened pro-
portional to torque (steering force) and direction of rotation. The
control edges of the proportional valve are arranged radially at
several levels on the rotary piston and the inside of the rotary valve
housing. A spring package assures a spring centered, closed mid-
position.

Adjustable parameters
External torque: -10 ... 10 N.m (0)
Displacement: 0 ... 10000 cm3 (32)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.1)

Steering unit (Orbitrol)

The steering unit is used to steer vehicles that are equipped with
hydrostatic steering.

The steering unit consists of a proportional rotary valve, a pump


control valve and a dosing pump. The rotary valve is opened pro-
portional to torque (steering force) and direction of rotation. The
control edges of the proportional valve are arranged radially at
several levels on the rotary piston and the inside of the rotary valve
housing. A spring package assures a spring centered, closed mid-
position.

Adjustable parameters

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 355
External torque: -10 ... 10 N.m (0)
Displacement: 0 ... 10000 cm3 (32)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.1)

Tank

The tank is integrated into the pump unit and has a pressure of 0
MPa. It can be inserted into the circuit diagram as an independent
component.

Hose with quick-action coupling

The hose is available in 3 lengths: 600 mm, 1500 mm, and 3000
mm. The pressure loss in a hose is taken into account by specifying
a hydraulic resistance. In FluidSIM no pressure loss is simulated
with simple connections between two components.

Adjustable parameters
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.1)

Hydraulic reservoir

The reservoir enables the performance of a hydraulic system to be


optimized. For example, it can be utilized as an energy reservoir
and for the absorbance of pressure surges or flow fluctuations.
Reservoirs are capable of absorbing a defined volume of fluid under
pressure and releasing it again with minimal losses. The construc-
tion consists essentially of a pressure resistant container, generally
a gas charge of nitrogen and a separator e.g. a piston, a membrane
or a bubble elastomer. Hydraulic fluid only starts to flow into the
reservoir when the fluid pressure is greater than the gas-preload
pressure.

Adjustable parameters

356 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Volume: 0.01 ... 100 l (0.32)
Pre-load pressure: 0 ... 40 MPa (1)
Polytropic exponent: 0.5 ... 3 (1.4)

Hydraulic reservoir

The reservoir enables the performance of a hydraulic system to be


optimized. For example, it can be utilized as an energy reservoir
and for the absorbance of pressure surges or flow fluctuations.
Reservoirs are capable of absorbing a defined volume of fluid under
pressure and releasing it again with minimal losses. The construc-
tion consists essentially of a pressure resistant container, generally
a gas charge of nitrogen and a separator e.g. a piston, a membrane
or a bubble elastomer. Hydraulic fluid only starts to flow into the
reservoir when the fluid pressure is greater than the gas-preload
pressure.

Adjustable parameters
Volume: 0.01 ... 100 l (0.32)
Pre-load pressure: 0 ... 40 MPa (1)
Polytropic exponent: 0.5 ... 3 (1.4)

Diaphragm accumulator with shutoff block

Stores the pressure and is equipped with a pressure relief valve to


prevent overpressure.

Adjustable parameters
Pre-load pressure: 0 ... 40 MPa (1)
Volume: 0.01 ... 100 l (0.32)
Opening pressure: 0 ... 35 MPa (8)

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 357
Filter

The filter limits the contamination of the fluid respecting a certain


tolerance value in order to reduce the risk of damage at the com-
ponents.

Adjustable parameters
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.001)

Cooler

An unacceptable fall in the hydraulic fluids viscosity can be avoid-


ed through the use of a cooler.

Adjustable parameters
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.001)

Heater

The hydraulic fluids optimal viscosity can be reached quickly


through the use of a heater.

Adjustable parameters
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.001)

Connection (hydraulic)

A hydraulic connection is a place where a hydraulic line can be


attached to. To simplify the line drawing process, a connection
appears as a small circle in Edit Mode. Hydraulic connections can
be shut by means of a blind plug. An open hydraulic connection

358 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
may result in leaking oil; FluidSIM thus pops up a warning mes-
sage, if some hydraulic connection was left open. Note that at each
hydraulic connection values for the flow and pressure can be dis-
played.

Line (hydraulic)

A hydraulic line is used to connect two hydraulic connectors. These


may be either a simple hydraulic connection or a T-junction.A
hydraulic line is normally treated as an ideal connection, with no
pressure drop being included in the simulation. A frictional loss
can be entered via the Physical model options. If you select
Simple resistance, only the Hydraulic resistance parameter will
be included in the simulation. If you select Pipe model (Hagen-
Poiseuille/Blasius), a complex empirical calculation is carried out
using a model based on Hagen-Poiseuille for laminar flows and a
model based on Blasius for turbulent flows, utilizing the Reynolds
number and the wall surface roughness.

Adjustable parameters
Physical model: Ideal connection,Simple resistance, Pipe model
(Hagen-Poiseuille/Blasius) (Ideal connection)
Length: 0.01 ... 1000 m (1)
Inner diameter: 0.1 ... 1000 mm (6.3)
Surface roughness: 0 ... 100 mm (0)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.08)

T-junction (hydraulic)

A T-junction joins up to four hydraulic lines, thus having a single


pressure potential. Note that T-junctions are introduced automati-
cally by FluidSIM when dropping the line drawing cursor onto
another line in Edit Mode.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 359
21.1.2 Configurable Way Valves

Configurable 2/n way valve

The configurable 2/n way valve is a way valve with two connec-
tions, where both its body elements and its operation modes are
user-definable.

Additionally, the hydraulic connections can be closed with blind


plug.

Adjustable parameters
Desired position: 0 ... 4 (0)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.164)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)

Configurable 3/n way valve

The configurable 3/n way valve is a way valve with three connec-
tions, where both its body elements and its operation modes are
user-definable.

360 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Additionally, the hydraulic connections can be closed with blind
plugs.

Adjustable parameters
Desired position: 0 ... 4 (0)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.164)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)

Configurable 4/n way valve

The configurable 4/n way valve is a way valve with three connec-
tions, where both its body elements and its operation modes are
user-definable.

Additionally, the hydraulic connections can be closed with blind


plugs.

Adjustable parameters
Desired position: 0 ... 4 (0)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.164)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 361
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)

Configurable 5/n way valve

The configurable 5/n way valve is a way valve with three connec-
tions, where both its body elements and its operation modes are
user-definable.

Additionally, the hydraulic connections can be closed with blind


plugs.

Adjustable parameters
Desired position: 0 ... 4 (0)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.164)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)

362 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Configurable 6/n way valve

The configurable 6/n way valve is a way valve with three connec-
tions, where both its body elements and its operation modes are
user-definable.

Additionally, the hydraulic connections can be closed with blind


plugs.

Adjustable parameters
Desired position: 0 ... 4 (0)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.164)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)

Configurable 8/n way valve

The configurable 8/n way valve is a way valve with three connec-
tions, where both its body elements and its operation modes are
user-definable.

Additionally, the hydraulic connections can be closed with blind


plugs.

Adjustable parameters

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 363
Desired position: 0 ... 4 (0)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.164)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)

21.1.3 Mechanically Actuated Directional Valves

2/2-way stem-Actuated valve (i)

If the cylinder piston actuates the stem, flow is enabled from P to A.

This valve is derived from a configurable 2/n way valve. You find
this valve in the component library Frequently used Way Valves,
under the Library menu.

Adjustable parameters
Desired position: 0 ... 4 (0)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.164)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)

364 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)

2/2-way stem-Actuated valve (ii)

If the cylinder piston actuate the stem, the flow from P to A is shut
off. This valve is derived from a configurable 2/n way valve. You
find this valve in the component library Frequently used Way
Valves, under the Library menu.

Adjustable parameters
Desired position: 0 ... 4 (0)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.164)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 365
3/2-way hand-lever valve

In normal position the connection P is closed and A to T opened.


When manually actuated T is shut off and P to A opened. This valve
is derived from a configurable 3/n way valve. You find this valve in
the component library Frequently used Way Valves, under the
Library menu.

Adjustable parameters
Desired position: 0 ... 4 (0)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.164)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)

4/2-way hand-lever valve (i)

In normal position the connection P is open to B and A to T. When


manually actuated the valve is set to parallel position. This valve is
derived from a configurable 4/n way valve. You find this valve in
the component library Frequently used Way Valves, under the
Library menu.

Adjustable parameters
Desired position: 0 ... 4 (0)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.164)
Positioning time: 1e-4 ... 10 s (0.02)

366 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)

4/2-way hand-lever valve (ii)

In normal position the connection P is open to A and B to T. When


manually actuated the valve is set to crossover position. This valve
is derived from a configurable 4/n way valve. You find this valve in
the component library Frequently used Way Valves, under the
Library menu.

Adjustable parameters
Desired position: 0 ... 4 (0)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.164)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 367
4/3-way hand-lever valve with shutoff position (i)

In normal position all connections are closed. When manually


actuated the valve is set to parallel or crossover position. This
valve is derived from a configurable 4/n way valve. You find this
valve in the component library Frequently used Way Valves,
under the Library menu.

Adjustable parameters
Desired position: 0 ... 4 (0)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.164)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)

4/3-way hand-lever valve with shutoff position (ii)

In normal position all connections are closed. When manually


actuated the valve is set to crossover or parallel position. This
valve is derived from a configurable 4/n way valve. You find this
valve in the component library Frequently used Way Valves,
under the Library menu.

Adjustable parameters
Desired position: 0 ... 4 (0)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.164)
Positioning time: 1e-4 ... 10 s (0.02)

368 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)

4/3-way hand-lever valve with floating position (i)

In normal position the connections A and B are open to T. When


manually actuated the valve is set to parallel or crossover position.
This valve is derived from a configurable 4/n way valve. You find
this valve in the component library Frequently used Way Valves,
under the Library menu.

Adjustable parameters
Desired position: 0 ... 4 (0)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.164)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 369
4/3-way hand-lever valve with floating position (ii)

In normal position the connections A and B are open to T. When


manually actuated the valve is set to crossover or parallel position.
This valve is derived from a configurable 4/n way valve. You find
this valve in the component library Frequently used Way Valves,
under the Library menu.

Adjustable parameters
Desired position: 0 ... 4 (0)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.164)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)

4/3-way hand-lever valve with bypass position (i)

In normal position the connections A and B are closed and P to T


opened. When manually actuated the valve is set to parallel or
crossover position. This valve is derived from a configurable 4/n
way valve. You find this valve in the component library Frequently
used Way Valves, under the Library menu.

Adjustable parameters
Desired position: 0 ... 4 (0)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.164)
Positioning time: 1e-4 ... 10 s (0.02)

370 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)

4/3-way hand-lever valve with bypass position (ii)

In normal position the connections A and B are closed and P to T


opened. When manually actuated the valve is set to crossover or
parallel position. This valve is derived from a configurable 4/n way
valve. You find this valve in the component library Frequently used
Way Valves, under the Library menu.

Adjustable parameters
Desired position: 0 ... 4 (0)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.164)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 371
21.1.4 Solenoid-actuated Directional Valves

4/2-way solenoid valve (i)

In normal position the connection P is open to B and A to T. When


actuated by the control solenoid, the valve is set to parallel posi-
tion. If no current is flowing through the control solenoid, the valve
can be manually actuated. This valve is derived from a configurable
4/n way valve. You find this valve in the component library Fre-
quently used Way Valves, under the Library menu.

Adjustable parameters
Desired position: 0 ... 4 (0)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.164)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)

372 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
4/2-way solenoid valve (ii)

In normal position the connection P is open to A and B to T. When


actuated by the control solenoid, the valve is set to crossover
position. If no current is flowing through the control solenoid, the
valve can be manually actuated. This valve is derived from a con-
figurable 4/n way valve. You find this valve in the component
library Frequently used Way Valves, under the Library menu.

Adjustable parameters
Desired position: 0 ... 4 (0)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.164)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)

4/3-way solenoid valve with shutoff position (i)

In normal position all connections are closed. When actuated by the


control solenoids, the valve is set to parallel or crossover position.
If no current is flowing through the control solenoids, the valve can
be manually actuated. This valve is derived from a configurable 4/n
way valve. You find this valve in the component library Frequently
used Way Valves, under the Library menu.

Adjustable parameters

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 373
Desired position: 0 ... 4 (0)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.164)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)

4/3-way solenoid valve with shutoff position (ii)

In normal position all connections are closed. When actuated by the


control solenoids, the valve is set to crossover or parallel position.
If no current is flowing through the control solenoids, the valve can
be manually actuated. This valve is derived from a configurable 4/n
way valve. You find this valve in the component library Frequently
used Way Valves, under the Library menu.

Adjustable parameters
Desired position: 0 ... 4 (0)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.164)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)

374 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)

4/3-way solenoid valve with floating position (i)

In normal position the connections A and B are open to T. When


actuated by the control solenoids, the valve is set to parallel or
crossover position. If no current is flowing through the control
solenoids, the valve can be manually actuated. This valve is derived
from a configurable 4/n way valve. You find this valve in the com-
ponent library Frequently used Way Valves, under the Library
menu.

Adjustable parameters
Desired position: 0 ... 4 (0)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.164)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)

4/3-way solenoid valve with floating position (ii)

In normal position the connections A and B are open to T. When


actuated by the control solenoids, the valve is set to crossover or
parallel position. If no current is flowing through the control sole-

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 375
noids, the valve can be manually actuated. This valve is derived
from a configurable 4/n way valve. You find this valve in the com-
ponent library Frequently used Way Valves, under the Library
menu.

Adjustable parameters
Desired position: 0 ... 4 (0)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.164)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)

4/3-way solenoid valve with bypass position (i)

In normal position the connections A and B are closed and P to T


opened. When actuated by the control solenoids, the valve is set to
parallel or crossover position. If no current is flowing through the
control solenoids, the valve can be manually actuated. This valve is
derived from a configurable 4/n way valve. You find this valve in
the component library Frequently used Way Valves, under the
Library menu.

Adjustable parameters
Desired position: 0 ... 4 (0)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.164)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)

376 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)

4/3-way solenoid valve with bypass position (ii)

In normal position the connections A and B are closed and P to T


opened. When actuated by the control solenoids, the valve is set to
crossover or parallel position. If no current is flowing through the
control solenoids, the valve can be manually actuated. This valve is
derived from a configurable 4/n way valve. You find this valve in
the component library Frequently used Way Valves, under the
Library menu.

Adjustable parameters
Desired position: 0 ... 4 (0)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.164)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 377
21.1.5 Shutoff Valves

Shutoff valve

The shutoff valve can be manually opened or closed. The hydraulic


resistance relates to the completely opened valve.

Adjustable parameters
Opening level: 0 ... 100 % (100)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.1)

Check valve

If the inlet pressure at A is higher than the outlet pressure at B,


then the check valve allows the flow to pass, otherwise it blocks the
flow.

Adjustable parameters
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.09)

Check valve, spring loaded

If the inlet pressure at A is higher than the outlet pressure at B and


the nominal pressure, then the check valve allows the flow to pass,
otherwise it blocks the flow.

Adjustable parameters
Opening pressure: 0 ... 40 MPa (0.6)
Pressure regulation range: 0.01 ... 10 MPa (0.864)

378 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.09)

Check valve with pilot control

If the input pressure is higher than the output pressure, the check
valve opens. Otherwise it is shut. In addition, the check valve can
be opened via a control line, allowing flow in both directions.

Adjustable parameters
Area ratio: 0.1 ... 10 (3.3)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.093)

Check valve with pilot control, spring loaded

If the input pressure is higher than the output and nominal pres-
sure, the check valve opens. Otherwise it is shut. In addition, the
check valve can be opened via a control line, allowing flow in both
directions.

Adjustable parameters
Opening pressure: 0 ... 40 MPa (0.2)
Pressure regulation range: 0.01 ... 10 MPa (0.864)
Area ratio: 0.1 ... 10 (3.3)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.093)

Double non-return valve, delockable

The valve is made up of two delockable non-return valves.

Adjustable parameters
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.093)
Area ratio: 0.1 ... 10 (3.3)

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 379
Double non-return valve, delockable

The valve is made up of two delockable non-return valves.

Adjustable parameters
Opening pressure: 0 ... 40 MPa (0.2)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.093)
Area ratio: 0.1 ... 10 (3.3)

Pilot to close check valve

If the inlet pressure at A is higher than the outlet pressure at B,


then the check valve allows the flow to pass, otherwise it blocks the
flow. Additionally, the check valve can be closed using the pilot line
X.

Adjustable parameters
Area ratio: 0.1 ... 10 (3.3)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.093)

Pilot to close check valve, spring loaded

If the inlet pressure at A is higher than the outlet pressure at B and


the nominal pressure, then the check valve allows the flow to pass,
otherwise it blocks the flow. Additionally, the check valve can be
closed using the pilot line X.

Adjustable parameters
Opening pressure: 0 ... 40 MPa (0.2)
Pressure regulation range: 0.01 ... 10 MPa (0.864)
Area ratio: 0.1 ... 10 (3.3)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.093)

380 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Shuttle valve

If one of the two input pressures is larger than zero, the shuttle
valve opens (OR function) and the higher input pressure becomes
the output pressure.

Adjustable parameters
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.09)

Two-pressure valve

If both input pressures are larger than zero, the two-pressure valve
opens (AND function) and the higher input pressure becomes the
output pressure.

Adjustable parameters
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.09)

21.1.6 Pressure Control Valves

Pressure relief valve

In normal position the valve is closed. If the opening pressure is


reached at P, T opens. When the pressure drops below the preset
level, the valve closes again. The flow direction is indicated by the
arrow. The hydraulic resistance relates to the completely opened
valve.

Adjustable parameters

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 381
Opening pressure: 0 ... 40 MPa (3)
Pressure regulation range: 0.01 ... 10 MPa (3.8)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.17)

Pressure relief valve

The valve restricts the pressure at port P to the set value compared
with the pressure at T.

If the differential pressure (dp=pP-pT) times the cross-sectional


area of the sealing cone exceeds the spring force, the sealing cone
lifts out of the seat and allows oil through to port T. The valve
closes again once the pressure in port P drops again. The cushion-
ing piston acts like a shock absorber to increase stability during the
control response. The spring pretension can be adjusted at the
handwheel. Oil flows through the non-return valve if the pressure at
port T is greater than at P.

Adjustable parameters
Opening pressure: 0 ... 40 MPa (3)
Pressure regulation range: 0.01 ... 10 MPa (3.5)
Hydraulic resistance (Pressure relief valve): 1e-6 ... 1000
bar.min2/l2 (0.08)
Hydraulic resistance (Non-return valve): 1e-6 ... 1000 bar.min2/l2
(0.06)

Pressure regulator, balanced

The valve restricts the pressure at port P to the set value compared
with the pressure at T.

If the hydraulic force at the sealing cone exceeds the spring force,
the sealing cone lifts out of the seat and allows oil to flow to port T.
The valve closes again once the pressure in port P drops again. The
cushioning piston acts like a shock absorber to increase stability.
The spring pretension can be adjusted at the hand wheel. Oil flows
through the non-return valve when the pressure at port T is greater

382 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
than at P. Since the spring chamber is separated from the oil by the
stem, the pressure in T has no effect on the limiting pressure.

Adjustable parameters
Nominal pressure: 0 ... 40 MPa (3)
Pressure regulation range: 0.01 ... 10 MPa (3.5)
Hydraulic resistance (Pressure relief valve): 1e-6 ... 1000
bar.min2/l2 (0.09)
Hydraulic resistance (Non-return valve): 1e-6 ... 1000 bar.min2/l2
(0.7)

Counterbalance valve

The valve limits pressure at port P vis--vis pressure applied to T to


the selected value.

Adjustable parameters
Opening pressure: 0 ... 40 MPa (3.0)
Pressure regulation range: 0.01 ... 10 MPa (1)
Hydraulic resistance (Pressure control valve): 1e-6 ... 1000
bar.min2/l2 (0.1)
Area ratio: 0.1 ... 10 (3)
Hydraulic resistance (Non-return valve): 1e-6 ... 1000 bar.min2/l2
(0.1)

Pressure sequence valve

The valve connects port P and port T if the pressure at port X is


greater than the total of the spring force and pressure in port T.

Adjustable parameters
Opening pressure: 0 ... 40 MPa (3)
Pressure regulation range: 0.01 ... 10 MPa (0.7)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.1)

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 383
Shutoff/counteracting valve

If the opening pressure is reached at the control line connection,


the valve opens from P to T. The hydraulic resistance relates to the
completely opened valve.

Adjustable parameters
Opening pressure: 0 ... 40 MPa (3)
Pressure regulation range: 0.01 ... 10 MPa (0.7)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.1)

Priority valve Load Sensing, dynamic

The priority valve assures that priority is given to outlet CF as


opposed to outlet EF.

Adjustable parameters
Spring preload: 0 ... 40 MPa (0.8)
Pressure regulation range: 0.01 ... 10 MPa (0.24)
Hydraulic resistance (P-CF): 1e-6 ... 1000 bar.min2/l2 (0.9)
Hydraulic resistance (P-EF): 1e-6 ... 1000 bar.min2/l2 (0.9)
Hydraulic resistance (CF): 1e-6 ... 1000 bar.min2/l2 (10)
Hydraulic resistance (LS-EF): 1e-6 ... 1000 bar.min2/l2 (1450)

Pressure relief valve with pilot control

In normal position the valve is closed. If the opening pressure is


reached at P, T opens. When the pressure drops below the preset
level, the valve closes again. In simple terms, the pilot pressure is
generated by the input pressure. The flow direction is indicated by
the arrow. The pilot operated pressure relief valve consists of a
pilot stage and a main stage. When open, there is less volumetric
flow at the pilot stage that leads internally to connection T. The
hydraulic resistance relates to the completely opened valve.

384 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Adjustable parameters
Opening pressure: 0 ... 40 MPa (3.5)
Pressure regulation range: 0.01 ... 10 MPa (3.5)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.08)

Pressure relief valve with pilot control

The valve is closed in the idle position. The hydraulic fluid drains off
at T, when the pressure difference at the connections P and T
exceeds the nominal pressure. If the pressure falls below the preset
value, the valve closes again. The flow direction is marked with an
arrow. The pilot operated pressure relief valve consists of a pilot
stage and a main stage. When open, there is less volumetric flow at
the pilot stage that leads to connection Y. The hydraulic resistance
relates to the completely opened valve.

Adjustable parameters
Opening pressure: 0 ... 40 MPa (3.5)
Pressure regulation range: 0.01 ... 10 MPa (3.5)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.08)

Shut-off-/counterbalancing valve

The valve connects port P with port T if the pressure set at control
port X is exceeded.

The hydraulic resistance relates to the completely opened valve.

Adjustable parameters
Opening pressure: 0 ... 40 MPa (3)
Pressure regulation range: 0.01 ... 10 MPa (0.7)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.1)

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 385
2-way pressure reducing valve

The pressure regulator valve regulates the pressure at connection A


to the preset operating pressure and equalizes the pressure fluctu-
ations. The valve closes when the pressure at connection A exceeds
the operating pressure. The setting of the real components is
component dependent and cannot be changed. The hydraulic
resistance relates to the completely opened valve.

Adjustable parameters
Nominal pressure: 0 ... 40 MPa (1)
Pressure regulation range: 0.01 ... 10 MPa (0.2)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.1)

2-way pressure reducing valve, adjustable

The pressure regulator valve regulates the pressure at connection A


to the preset operating pressure and equalizes the pressure fluctu-
ations. The valve closes when the pressure at connection A exceeds
the operating pressure.

Adjustable parameters
Nominal pressure: 0 ... 40 MPa (1)
Pressure regulation range: 0.01 ... 10 MPa (0.2)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.1)

3-way pressure reducing valve

The pressure reducing valve maintains a constant output pressure


despite fluctuating input pressure. The hydraulic fluid is drained off
at T when the pressure at connection A exceeds the operating
pressure. The hydraulic resistance relates to the completely
opened valve.

Adjustable parameters

386 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Nominal pressure: 0 ... 40 MPa (3)
Pressure regulation range: 0.01 ... 10 MPa (1.9)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.1)

Pressure compensator, upstream

The pressure compensator maintains the differential pressure


between port A und port X.

If, for example, a throttle point is located between A and X, pres-


sure is held constant over the throttle point. This corresponds to
the function of a 2-way flow control valve.

Adjustable parameters
Opening pressure: 0 ... 40 MPa (0.4)
Pressure regulation range: 0.01 ... 10 MPa (0.15)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.06)

Pressure compensator, upstream

The pressure compensator maintains the differential pressure


between port A und port X.

If, for example, a throttle point is located between A and X, pres-


sure is held constant over the throttle point. This corresponds to
the function of a 2-way flow control valve.

Adjustable parameters
Opening pressure: 0 ... 40 MPa (0.4)
Pressure regulation range: 0.01 ... 10 MPa (0.15)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.06)

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 387
Pressure compensator, downstream

The valve is used as a downstream pressure compensator for flow


control in combination with a pump controlled by means of load
sensing (variable volume LS pump).

Adjustable parameters
Opening pressure: 0 ... 40 MPa (0.02)
Pressure regulation range: 0.01 ... 10 MPa (0.018)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.058)

Pressure compensator, downstream

The valve is used as a downstream pressure compensator for flow


control in combination with a pump controlled by means of load
sensing (variable volume LS pump).

Adjustable parameters
Opening pressure: 0 ... 40 MPa (0.02)
Pressure regulation range: 0.01 ... 10 MPa (0.018)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.058)

Pressure compensator for open centre load sensing

P -> T, pX = 0 MPa: Pressure at P pushes the piston against the


spring. As of adjusted pressure, the valve opens: P -> T. P -> T, pX > 0
MPa: Pressure at X is added to spring force. The valve opens as
soon as opening pressure plus spring pressure is greater than pX.

Adjustable parameters
Opening pressure: 0 ... 40 MPa (0.4)
Pressure regulation range: 0.01 ... 10 MPa (0.15)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.058)

388 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Pressure compensator for open centre load sensing

P -> T, pX = 0 MPa: Pressure at P pushes the piston against the


spring. As of adjusted pressure, the valve opens: P -> T. P -> T, pX > 0
MPa: Pressure at X is added to spring force. The valve opens as
soon as opening pressure is greater than pX.

Adjustable parameters
Opening pressure: 0 ... 40 MPa (0.4)
Pressure regulation range: 0.01 ... 10 MPa (0.15)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.058)

Pilot valves, 2x2-channel

2-channel hydraulic pilot control is used. Each channel consists of


two pressure regulators. Depending on direction, the hand lever
actuates one of the two pressure regulators via a rocker. Pressure
is then regulated at the respective pilot port proportional to deflec-
tion.

Adjustable parameters
Maximum pressure: 0 ... 40 MPa (1.5)
Displacement (Left group): -100 ... 100 % (0)
Displacement (Right group): -100 ... 100 % (0)

Shock and anti-cavitation valve

The valve limits pressure from port A or B vis--vis pressure applied


to T to the selected value.

Adjustable parameters
Opening pressure (Left group): 0 ... 40 MPa (3)
Pressure regulation range (Left group): 0.01 ... 10 MPa (3.8)
Hydraulic resistance (Left group): 1e-6 ... 1000 bar.min2/l2 (0.08)
Opening pressure (Right group): 0 ... 40 MPa (3)

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 389
Pressure regulation range (Right group): 0.01 ... 10 MPa (3.8)
Hydraulic resistance (Right group): 1e-6 ... 1000 bar.min2/l2
(0.08)

Closing pressure compensator

The pressure compensator represents a pressure dependent hy-


draulic resistance. The pressure compensator closes when the
pressure difference X-Y exceeds the nominal pressure. A pressure
regulating valve is implemented by the combination of connections
A and X. The pressure balance is also a component of 2-way flow
control valves. The nominal pressure setting of the real compo-
nents is component dependent and cannot be changed. The hy-
draulic resistance relates to the completely opened valve.

Adjustable parameters
Nominal pressure: 0 ... 40 MPa (1)
Pressure regulation range: 0.01 ... 10 MPa (0.2)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.1)

Closing pressure compensator, adjustable

The pressure compensator represents a pressure dependent hy-


draulic resistance. The pressure compensator closes when the
pressure difference X-Y exceeds the nominal pressure. A pressure
regulating valve is implemented by the combination of the connec-
tions A and X. The hydraulic resistance relates to the completely
opened valve.

Adjustable parameters
Nominal pressure: 0 ... 40 MPa (1)
Pressure regulation range: 0.01 ... 10 MPa (0.2)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.1)

390 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Opening pressure compensator

The pressure compensator represents a pressure dependent hy-


draulic resistance. The pressure compensator opens when the
pressure difference X-Y exceeds the nominal pressure. A pressure
relief valve is implemented by the combination of connections P
and X. The pressure balance is also a component of 3-way flow
control valves. The nominal pressure setting of the real compo-
nents is component dependent and cannot be changed. The hy-
draulic resistance relates to the completely opened valve.

Adjustable parameters
Nominal pressure: 0 ... 40 MPa (1)
Pressure regulation range: 0.01 ... 10 MPa (0.2)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.1)

Opening pressure compensator, adjustable

The pressure compensator represents a pressure dependent hy-


draulic resistance. The pressure compensator opens when the
pressure difference X-Y exceeds the nominal pressure. A pressure
relief valve is implemented by the combination of connections P
and X. The hydraulic resistance relates to the completely opened
valve.

Adjustable parameters
Nominal pressure: 0 ... 40 MPa (1)
Pressure regulation range: 0.01 ... 10 MPa (0.2)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.1)

Opening cartridge valve

The 2/2-way cartridge valve is a 2/2-way valve. It is fitted with two


working ports and the two switch positions closed and open.
Whether or not the cartridge valve is open or closed depends on

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 391
the effective areas A, B and X, the adjacent pressures pA, pB and
pX, as well as the spring force. A+B=X is valid. If pA*A + pB*B >
pX*X + F, then the valve opens, otherwise it is closed. The valve
therefore operates purely pressure dependent and can, with the
appropriate control, assume directional-, flow- and pressure func-
tions. The spring force is specified by means of the nominal pres-
sure. This is the minimum pressure, with pressureless connections
at B and X, necessary at connection A to open the valve. Whether
the valve has one (A=B) or two (A <> B) effective areas can be speci-
fied in the properties window. The relevant symbol is automatically
depicted. The hydraulic resistance relates to the completely opened
valve.

Adjustable parameters
Opening pressure: 0 ... 40 MPa (0.5)
Area A: 0.1 ... 100 cm2 (6)
Area B: 0.1 ... 100 cm2 (3)
Pressure regulation range: 0.01 ... 10 MPa (0.05)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.01)

Closing cartridge valve

The 2/2-way cartridge valve is a 2/2-way valve. It is fitted with two


working ports and the two switch positions closed and open.
Whether or not the cartridge valve is open or closed depends on
the effective areas A and X, the adjacent pressures pA, and pX, as
well as the spring force. A=X is valid. If pA*A > pX*X + F, then the
valve closes, otherwise it is open. The valve therefore operates
purely pressure dependent and can, with the appropriate control,
assume directional-, flow- and pressure functions. The spring force
is specified by means of the nominal pressure. This is the minimum
pressure, with pressureless connections at B and X, necessary at
connection A to open the valve. The hydraulic resistance relates to
the completely opened valve.

Adjustable parameters
Opening pressure: 0 ... 40 MPa (0.5)
Area: 0.1 ... 100 cm2 (6)
Pressure regulation range: 0.01 ... 10 MPa (0.05)

392 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.01)

21.1.7 Pressure Switches

Analog pressure sensor

The pressure switch takes the pressure and actuates the associat-
ed electrical pressure switch if the preset switching pressure is
exceeded.

Adjustable parameters
Switching pressure: -0.1 ... 40 MPa (3)
Hysteresis: 0 ... 10 MPa (0)

21.1.8 Flow Control Valves

Nozzle

The nozzle represents a hydraulic resistance.

Adjustable parameters
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.19)

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 393
Throttle valve

The setting of the throttle valve is set by means of a rotary knob.


Please note that by the rotary knob no absolute resistance value
can be set. This means that, in reality, different throttle valves can
generate different resistance values despite identical settings.

Adjustable parameters
Opening level: 0 ... 100 % (100)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.19)

Orifice

The orifice represents a hydraulic resistance.

Adjustable parameters
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.19)

Orifice, adjustable

The orifice represents a variable hydraulic resistance.

Adjustable parameters
Opening level: 0 ... 100 % (100)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.19)

One-way flow control valve

The setting of the One-way flow control valve is set by means of a


rotary knob. A check valve (see check valve) is located parallel to
the throttle valve. Please note that by the rotary knob no absolute

394 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
resistance value can be set. This means that, in reality, different
throttle valves can generate different resistance values despite
identical settings.

Adjustable parameters
Opening level: 0 ... 100 % (100)
Hydraulic resistance (Flow control valve): 1e-6 ... 1000
bar.min2/l2 (0.07)
Hydraulic resistance (Non-return valve): 1e-6 ... 1000 bar.min2/l2
(0.05)

2-way flow control valve

If the pressure is sufficient, the preset flow is maintained to a


constant level in the direction of the arrow. The hydraulic resistance
relates to the completely opened valve.

Adjustable parameters
Nominal flow: 0 ... 500 l/min (1)
Spring preload: 0 ... 10 MPa (0.6)
Pressure regulation range: 0.01 ... 10 MPa (0.05)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.3)

2-way flow control valve

If the pressure is sufficient, the preset flow is maintained to a


constant level in the direction of the arrow. The hydraulic resistance
relates to the completely opened valve.

Adjustable parameters
Nominal flow: 0 ... 500 l/min (1)
Spring preload: 0 ... 10 MPa (0.45)
Pressure regulation range: 0.01 ... 10 MPa (0.05)
Hydraulic resistance (Flow control valve): 1e-6 ... 1000
bar.min2/l2 (0.4)
Hydraulic resistance (Non-return valve): 1e-6 ... 1000 bar.min2/l2

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 395
(0.08)

3-way flow control valve

With sufficient pressure, the preset flow rate is kept constant in the
direction of the arrow. The surplus hydraulic fluid is drained at
connection T using a pressure compensator. The inlet pressure pA
is load dependent, i.e it changes with the outlet pressure pB. There-
fore a parallel circuit of several 3-way flow control valves is not
possible. In this case, the inlet pressures would be defined by the
valve with the lowest inlet pressure. Compared to the 2-way flow
control valve, the 3-way flow control valve is admittedly more
efficient in its energy consumption. The hydraulic resistance relates
to the completely closed pressure compensator.

Adjustable parameters
Nominal flow: 0 ... 500 l/min (1)
Spring preload: 0 ... 10 MPa (0.5)
Pressure regulation range: 0.01 ... 10 MPa (0.05)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.4)

Flow divider valve

The flow divider valve divides the flow from P into two equal flows
at A and B. This is achieved using two measuring orifices and two
variable control resistors. The control resistors are unified in a
pressure compensator. The hydraulic resistance relates to the
resistance of the individual measuring orifices and control resis-
tors.

Adjustable parameters
Hydraulic resistance (Pressure compensator): 1e-6 ... 1000
bar.min2/l2 (0.375)
Hydraulic resistance (Metering orifice): 1e-6 ... 1000 bar.min2/l2
(0.537)

396 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Flush valve with pressure relief valve

If differential pressure exceeds the required force for the spring, the
valve opens from B to the pressure-relief valve.

The pressure-relief valve assures that pressure on the suction side


does not drop to below the required minimum pressure for the
pump.

Adjustable parameters
Spring preload: 0 ... 40 MPa (0.25)
Hydraulic resistance (Directional valve): 1e-6 ... 1000 bar.min2/l2
(0.08)
Opening pressure: 0 ... 40 MPa (0.5)
Hydraulic resistance (Pressure control valve): 1e-6 ... 1000
bar.min2/l2 (0.08)

21.1.9 Continuous valves

4/3-way regulating valve

The regulating valve transforms an analog electrical input signal


into corresponding opening cross-sections at the outputs. The
setpoint signal must be within the range -10 V to +10 V. At 0 V the
hydraulic mid-position is adopted and the valve stops the flow (in
relation to the null overlap). The cross section area of the flow
opening widens with increasing slide distance. How far the area,
and with it the flow at the valve, changes depends on the shape
and form of the control notches. A triangular shaped notch results
in a progressive flow behavior, a rectangular shaped notch in a
linear flow behavior. The hydraulic resistance relates to a complete-
ly opened leading edge and the internal leakage relates to one

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 397
leading edge as appropriate. The overlap of the leading edges can
be specified relative to the maximal slide distance. By the use of an
integrated electronic position controller for the slide distance,
beneficial static and dynamic characteristics are achieved that are
manifested in a minimal hysteresis (less than 0,2 %) and a re-
sponse time of less than 12 ms at a signal change of 0 - 100

Adjustable parameters
Control notch shape: Rectangular, Triangular (Rectangular)
Relative spool overlap: -50 ... 50 % (0)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (1.4)
Leakage: 0 ... 10 l/(min.bar) (0.00026)

4/3-way proportional valve

By use of a twin-channel proportional amplifier, the proportional


valve transforms an analog electrical input signal into correspond-
ing opening cross-sections at the outputs. The setpoint signal must
be within the range -10 V to +10 V. At 0 V the hydraulic mid-position
is adopted and the valve stops the flow (in relation to the null
overlap). The cross section area of the flow opening widens by
increasing slide distance. How far the area, and with it the flow at
the valve, changes depends on the shape and form of the control
notches. A triangular shaped notch results in a progressive flow
behavior, a rectangular shaped notch in a linear flow behavior. The
hydraulic resistance relates to a completely opened leading edge
and the internal leakage relates to one leading edge as appropri-
ate. The overlap of the leading edges can be specified relative to
the maximal slide distance.

Adjustable parameters
Control notch shape: Rectangular, Triangular (Triangular)
Relative spool overlap: -50 ... 50 % (25)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (3.2)
Leakage: 0 ... 10 l/(min.bar) (0.001)

398 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Proportional throttle valve

In order to alter the flow rate through the valve, the cross section of
the throttle valve is electrically manipulated with the assistance of
a proportional amplifier. The control voltage must be between 0 V
and 10 V. The deflection of the slide is proportional to the applied
voltage. At 0 V the valve is completely closed (in relation to the null
overlap). The hydraulic resistance relates to the completely opened
valve. The overlap of the leading edges can be specified relative to
the maximal slide distance.

Adjustable parameters
Control notch shape: Rectangular, Triangular (Triangular)
Relative spool overlap: -50 ... 50 % (0)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.1)
Leakage: 0 ... 10 l/(min.bar) (0)

Proportional pressure relief valve

The proportional pressure relief valve, with the assistance of a


proportional amplifier, is a continuous, electrically adjustable
pressure relief valve. The control piston has two adjacent areas
exposed to pressure. The first area is exposed to the pressure at
connection P, the other to connection T. If the magnet is not sup-
plied with electricity, then the piston is fully retracted and the
complete passage from connection P to connection T is free. The
proportional magnet creates a force proportional to its magnetic
current, which moves the control piston according to the balance of
the adjacent forces (magnetic force, spring force and pressures).
The control voltage must be in the range 0 V to 10 V. The minimum
nominal pressure defines the opening pressure through the spring
force at 0 V. The maximum nominal pressure defines the opening
pressure at 10 V. The hydraulic resistance relates to the completely
opened main stage leading edge.

Adjustable parameters
Min. Opening pressure: 0 ... 40 MPa (0)
Max. Opening pressure: 0 ... 40 MPa (10)

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 399
Pressure regulation range: 0.01 ... 10 MPa (2)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.1)

Proportional pressure relief valve, piloted

The pilot operated pressure relief valve consists of a pilot stage


with poppet valve and a main stage with control slide valve. The
pressure at connection P acts upon the pilot poppet via a drilling in
the control slide valve. If the force of the proportional magnet is
greater than the pressure exercised at connection P, then the pilot
stage remains closed. A spring keeps the main stage poppet valve
closed and the flow rate is null. If the force, that the pressure exer-
cises, exceeds the closing force of the pilot poppet, then this
opens. A lower flow rate develops from connection P to connection
Y. The flow of fluid causes a pressure loss at the throttle valve
inside the control slide valve. Thus the pressure at the spring side
is lower than the pressure at connection P. Due to the pressure
difference, the control slide valve opens so far until the spring force
re-establishes an equilibrium of forces and the valve is perfused
from P to T. The control voltage must be between 0 V and 10 V. The
minimum nominal pressure defines the opening pressure at the
pilot stage via the spring force at 0 V. The maximum nominal pres-
sure defines the opening pressure at 10 V. The hydraulic resistance
relates to the completely opened main stage leading edge.

Adjustable parameters
Min. Opening pressure: 0 ... 40 MPa (0)
Max. Opening pressure: 0 ... 40 MPa (10)
Pressure regulation range: 0.01 ... 10 MPa (2)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.05)

Proportional pressure reducing valve, piloted

The pilot operated proportional pressure regulator valve consists of


a pilot stage with poppet valve and a main stage with control slide
valve. The pressure at connection A acts upon the pilot poppet via a
drilling in the control slide valve. The proportional magnet exercises

400 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
the electrically adjustable counter force with the assistance of a
proportional amplifier. If the pressure at connection A is below the
preset value, then the pilot control remains closed. The pressure on
both sides of the control slide valve is equal. A spring holds the
main stage control slide valve open and the hydraulic fluid flow
freely from connection P to connection A. If the pressure at connec-
tion A exceeds the preset value, then the pilot stage opens causing
less volumetric flow to flow to connection A. The pressure falls at
the throttle valve inside the control slide valve. Thus the pressure
at the spring side is lower than the pressure at connection A. Due to
the pressure difference, the control slide valve closes so far until
the spring force re-establishes an equilibrium of forces. As a result,
the flow resistance at the control edge between connections P and
A increases and the pressure at connection A sinks. The control
voltage must be between 0 V and 10 V. The minimum nominal
pressure defines the opening pressure at the pre stage via the
spring force at 0 V. The maximum nominal pressure defines the
opening pressure at 10 V. The hydraulic resistance relates to the
completely opened main stage leading edge.

Adjustable parameters
Min. Nominal pressure: 0 ... 40 MPa (0)
Max. Nominal pressure: 0 ... 40 MPa (3)
Pressure regulation range: 0.01 ... 10 MPa (0.1)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.05)

6/3-way proportional hand lever valve

The valve is used to control volumetric flow. Flow rate and direction
of flow are controlled. The mid-position is spring centered. The
piston is pushed out of its mid-position and against the spring with
the hand lever.

Adjustable parameters
Displacement: -100 ... 100 % (0)
Hydraulic resistance (P1->T1): 1e-6 ... 1000 bar.min2/l2 (0.045)
Hydraulic resistance (P2->A,B): 1e-6 ... 1000 bar.min2/l2 (0.051)
Hydraulic resistance (T2->A,B): 1e-6 ... 1000 bar.min2/l2 (0.0362)
Leakage: 0 ... 10 l/(min.bar) (5E-06)

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 401
Mobile valve block, Load sensing

The valve block has two slices, each with a proportional directional
control valve for controlling speed and direction. The directional
control valve in each slice has an upstream pressure compensator.
As a result, the slice functions like a proportional current regulator.

Adjustable parameters
Displacement (Left group): -100 ... 100 % (0)
Displacement (Right group): -100 ... 100 % (0)

21.1.10 Actuators

Configurable cylinder

The configurable cylinder can be customized via its properties


dialog. Almost any combination of piston type (single-acting, dou-
ble-acting), the specification of the piston rods (double ended, with
magnetic coupling or slide) and the number (none, one, two) is
possible. An end position cushioning (without, with, adjustable)
can also be defined. FluidSIM automatically adjusts the symbol
according to the preset configuration. In addition, a load to be
moved (including possible static and sliding friction) and a variable
force profile can be defined in the properties dialog. In the compo-
nent library from FluidSIM there are several pre-configured cylin-
ders that can be inserted in your circuit and directly used. Should
no suitable symbol be available, then simply choose the compo-
nent with the most similarity to the required component, open the
properties dialog and adjust the configuration accordingly.

Adjustable parameters

402 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Piston diameter: 1 ... 1000 mm (16)
Piston rod diameter: 0 ... 1000 mm (10)
Piston Position: 0 ... 5000 mm (0)
Maximum stroke: 1 ... 5000 mm (200)
Mounting angle: 0 ... 360 deg (0)
Parameter input: Calculate automatically, Enter manually (Calcu-
late automatically)
Break-away force: 0 ... 10000 N (65)
Coulomb friction force: 0 ... 10000 N (55)
Viscous friction: 0.1 ... 10000 N.s/m (215)
Parameter input: Calculate automatically, Enter manually (Calcu-
late automatically)
Moving mass: 0.01 ... 1000 kg (0.3)
Leakage: 0 ... 10 l/(min.bar) (0)
Spring pressure at x=0: 0 ... 40 MPa (0.4)
Spring pressure at x=x_max: 0 ... 40 MPa (1)
Damping length: 0 ... 100 mm (10)

Double acting cylinder

Double acting cylinder with piston rod on one side. The piston of
the cylinder contains a permanent solenoid which can be used to
operate a proximity switch.

Adjustable parameters
Piston diameter: 1 ... 1000 mm (16)
Piston rod diameter: 0 ... 1000 mm (10)
Piston Position: 0 ... 5000 mm (0)
Maximum stroke: 1 ... 5000 mm (200)
Mounting angle: 0 ... 360 deg (0)
Parameter input: Calculate automatically, Enter manually (Calcu-
late automatically)
Break-away force: 0 ... 10000 N (65)
Coulomb friction force: 0 ... 10000 N (55)
Viscous friction: 0.1 ... 10000 N.s/m (215)
Parameter input: Calculate automatically, Enter manually (Calcu-
late automatically)
Moving mass: 0.01 ... 1000 kg (0.3)
Leakage: 0 ... 10 l/(min.bar) (0)
Spring pressure at x=0: 0 ... 40 MPa (0.4)
Spring pressure at x=x_max: 0 ... 40 MPa (1)

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 403
Damping length: 0 ... 100 mm (10)

Double acting cylinder with shock adsorber at stroke end

The piston of the cylinder is controlled by the connected pressure


loads. The shock adsorber can be adjusted by means of two ad-
justment screws. The piston contains a permanent solenoid which
can be used to operate a proximity switch.

Adjustable parameters
Piston diameter: 1 ... 1000 mm (16)
Piston rod diameter: 0 ... 1000 mm (10)
Piston Position: 0 ... 5000 mm (0)
Maximum stroke: 1 ... 5000 mm (200)
Mounting angle: 0 ... 360 deg (0)
Parameter input: Calculate automatically, Enter manually (Calcu-
late automatically)
Break-away force: 0 ... 10000 N (65)
Coulomb friction force: 0 ... 10000 N (55)
Viscous friction: 0.1 ... 10000 N.s/m (215)
Parameter input: Calculate automatically, Enter manually (Calcu-
late automatically)
Moving mass: 0.01 ... 1000 kg (0.3)
Leakage: 0 ... 10 l/(min.bar) (0)
Spring pressure at x=0: 0 ... 40 MPa (0.4)
Spring pressure at x=x_max: 0 ... 40 MPa (1)
Damping length: 0 ... 100 mm (10)

Double acting cylinder with in and out piston rod and shock
adsorber at stroke end

The piston of the cylinder is controlled by the connected pressure


loads. The shock adsorber can be adjusted by means of two ad-
justment screws. The piston of the cylinder contains a permanent
solenoid which can be used to operate a proximity switch.

Adjustable parameters

404 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Piston diameter: 1 ... 1000 mm (16)
Piston rod diameter: 0 ... 1000 mm (10)
Piston Position: 0 ... 5000 mm (0)
Maximum stroke: 1 ... 5000 mm (200)
Mounting angle: 0 ... 360 deg (0)
Parameter input: Calculate automatically, Enter manually (Calcu-
late automatically)
Break-away force: 0 ... 10000 N (65)
Coulomb friction force: 0 ... 10000 N (55)
Viscous friction: 0.1 ... 10000 N.s/m (215)
Parameter input: Calculate automatically, Enter manually (Calcu-
late automatically)
Moving mass: 0.01 ... 1000 kg (0.3)
Leakage: 0 ... 10 l/(min.bar) (0)
Spring pressure at x=0: 0 ... 40 MPa (0.4)
Spring pressure at x=x_max: 0 ... 40 MPa (1)
Damping length: 0 ... 100 mm (10)

Single acting cylinder

By connecting a sufficiently high pressure load, the piston of the


cylinder is extended to its stop. To move the piston back, an exter-
nal force must be applied.

Adjustable parameters
Piston diameter: 1 ... 1000 mm (16)
Piston rod diameter: 0 ... 1000 mm (10)
Piston Position: 0 ... 5000 mm (0)
Maximum stroke: 1 ... 5000 mm (200)
Mounting angle: 0 ... 360 deg (0)
Parameter input: Calculate automatically, Enter manually (Calcu-
late automatically)
Break-away force: 0 ... 10000 N (65)
Coulomb friction force: 0 ... 10000 N (55)
Viscous friction: 0.1 ... 10000 N.s/m (215)
Parameter input: Calculate automatically, Enter manually (Calcu-
late automatically)
Moving mass: 0.01 ... 1000 kg (0.3)
Leakage: 0 ... 10 l/(min.bar) (0)
Spring pressure at x=0: 0 ... 40 MPa (0.4)
Spring pressure at x=x_max: 0 ... 40 MPa (1)

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 405
Damping length: 0 ... 100 mm (10)

Loading unit/cylinder load simulator

Two cylinders are positioned opposite each other. Various cylinder


types and loads can be combined using the four piston surfaces.

Adjustable parameters
Piston diameter: 1 ... 1000 mm (16)
Piston rod diameter: 1 ... 1000 mm (10)
Piston Position: 0 ... 5000 mm (0)
Maximum stroke: 1 ... 10000 mm (200)
Mounting angle: 0 ... 360 deg (0)
Moving mass: 0.01 ... 1000 kg (0.6)
Opening pressure: 0 ... 40 MPa (12)
Break-away force: 0 ... 10000 N (65)
Coulomb friction force: 0 ... 10000 N (55)
Viscous friction: 0.1 ... 10000 N.s/m (215)

Loading unit/cylinder load simulator

Two cylinders are positioned opposite each other. Various cylinder


types and loads can be combined using the four piston surfaces.

Adjustable parameters
Piston diameter: 1 ... 1000 mm (16)
Piston rod diameter: 1 ... 1000 mm (10)
Piston Position: 0 ... 5000 mm (0)
Maximum stroke: 1 ... 10000 mm (200)
Mounting angle: 0 ... 360 deg (0)
Moving mass: 0.01 ... 1000 kg (0.6)
Break-away force: 0 ... 10000 N (65)
Coulomb friction force: 0 ... 10000 N (55)
Viscous friction: 0.1 ... 10000 N.s/m (215)

406 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Hydraulic motor

The hydraulic motor transforms hydraulic energy into mechanical


energy.

Adjustable parameters
External torque: -1000 ... 1000 N.m (0)
Displacement: 0.001 ... 5 l (0.008)
Friction: 0.001 ... 100 N.m.s/rad (0.0108)
Moment of inertia: 0.0001 ... 10 kg.m2 (0.0001)
Leakage: 0 ... 10 l/(min.bar) (0.0126)

Semi-rotary actuator

The semi-rotary actuator is controlled by alternately switching the


pressure. In the end positions the swivel cylinder can activate
switches or valves via labels.

Adjustable parameters
Initial Position: 0 ... 360 deg (0)
Rotation angle (max): 1 ... 360 deg (180)
Displacement: 0.01 ... 1000 l (0.1)
Friction: 0.01 ... 100 N.m.s/rad (0.1)
Moment of inertia: 1e-005 ... 1 kg.m2 (0.0001)
External torque: -1000 ... 1000 N.m (0)

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 407
21.1.11 Measuring Devices

Manometer

The manometer measures the pressure at its connection.

Differential pressure gauge

The differential pressure gauge displays the pressure difference


between the adjacent pressures at the left and the right connection.

Pressure indicator

An optical signal is activated when the pressure at the connection


to the pressure display exceeds the preset switching pressure.

Adjustable parameters
Switching pressure: -0.1 ... 40 MPa (3)

Pressure sensor, analog

This symbol represents the hydraulic part of the analog pressure


sensor. The analog pressure sensor measures the adjacent pres-
sure and transforms it into a proportional electrical voltage signal.
In the process, only pressures in the specified pressure ranges are
considered. Within this range, the pressure in the voltage range
from 0 V to 10 V is represented, i.e. the minimum pressure delivers
0 V and the maximum pressure 10 V.

Adjustable parameters

408 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Minimum pressure: -40 ... 40 MPa (0)
Maximum pressure: -40 ... 40 MPa (10)
Voltage at p1: -100 ... 100 V (0)
Voltage at p2: -100 ... 100 V (10)

Flow meter

The flow meter measures the flow rate. Either the current flow or
the total quantity flowed can be displayed. The component image is
automatically adjusted accordingly.

Adjustable parameters
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.001)

Flow meter

The flow meter consists of a hydraulic motor connected to an RPM


gauge.

Adjustable parameters
Displacement: 0.1 ... 5000 cm3 (8.2)
Friction: 0.001 ... 100 N.m.s/rad (0.0108)
Moment of inertia: 0.0001 ... 10 kg.m2 (0.0001)
Leakage: 0 ... 10 l/(min.bar) (0.0126)
Flow Direction: Ignore, Consider (Ignore)
Flow rate (min): -500 ... 500 l/min (0)
Flow rate (max): -500 ... 500 l/min (10)
Voltage (q1): -100 ... 100 V (0)
Voltage (q2): -100 ... 100 V (10)

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 409
Flow meter, analog

This symbol represents the hydraulic part of the analog flow meter.
The analog flow meter measures the volumetric flow and trans-
forms it into a proportional electrical voltage signal. In the process,
only flow rates in the specified pressure ranges are considered.
Within this range, the flow rate in the voltage range from 0 V to 10 V
is represented, i.e. the minimum volumetric flow delivers 0 V and
the maximum volumetric flow 10 V.

Adjustable parameters
Flow Direction: Ignore, Consider (Ignore)
Flow rate (min): -500 ... 500 l/min (0)
Flow rate (max): -500 ... 500 l/min (10)
Voltage (q1): -100 ... 100 V (0)
Voltage (q2): -100 ... 100 V (10)
Hydraulic resistance: 1e-6 ... 1000 bar.min2/l2 (0.001)

21.2 Pneumatic Components

21.2.1 Supply Elements

Compressed air supply

The compressed air supply provides the needed compressed air. It


contains a pressure control valve that can be adjusted to output the
desired operating pressure.

Adjustable parameters

410 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Operating pressure: 0 ... 2 MPa (0.6)
Max. flow rate: 0 ... 5000 l/min (1000)
Volume: 0.001 ... 1000 l (0.1)

Compressor

The compressor provides the necessary compressed air. The pres-


sure is restricted to the preset operating pressure.

Adjustable parameters
Operating pressure: 0 ... 2 MPa (0.6)
Max. flow rate: 0 ... 5000 l/min (1000)
Volume: 0.001 ... 1000 l (0.1)

Compressor, adjustable

The adjustable compressor provides the necessary compressed air,


whereby the maximum flow rate can be adjusted under actual
operating conditions and in the simulation. The pressure is restrict-
ed to the preset operating pressure.

Adjustable parameters
Operating pressure: 0 ... 2 MPa (0.6)
Max. flow rate: 0 ... 5000 l/min (1000)
Volume: 0.001 ... 1000 l (0.1)

Air service unit, simplified representation

The service unit is made up of a compressed air filter with water


separator and a pressure control valve.

Adjustable parameters

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 411
Nominal pressure: 0 ... 2 MPa (0.4)
Standard nominal flow rate (Pressure regulator): 0.1 ... 5000
l/min (300)
Standard nominal flow rate (Filter): 0.1 ... 5000 l/min (1000)

Air service unit

The service unit is made up of a compressed air filter with water


separator and a pressure control valve.

Adjustable parameters
Nominal pressure: 0 ... 2 MPa (0.4)
Standard nominal flow rate (Pressure regulator): 0.1 ... 5000
l/min (300)
Standard nominal flow rate (Filter): 0.1 ... 5000 l/min (1000)

Start-up valve with filter control valve

The filter with water separator cleans the compressed air of dirt,
pipe scale, rust and condensate. The pressure regulator adjusts the
compressed air supplied to the set operating pressure and com-
pensates for pressure fluctuations. The pressure gauge shows the
preset pressure. The on/off valve exhausts the entire control.

Manifold

The manifold enables a control system to be supplied with com-


pressed air eight individual connections.

412 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Air pressure reservoir

The air pressure reservoir serves as compensation for pressure


fluctuations and is utilized (as a reservoir) for abruptly occurring air
consumption. Large time delays can be attained when used in
conjunction with time delay- and throttle valves.

Adjustable parameters
Volume: 0.001 ... 1000 l (1)

Air pressure reservoir (2 Connections)

The air pressure reservoir serves as compensation for pressure


fluctuations and is utilized (as a reservoir) for abruptly occurring air
consumption. Large time delays can be attained when used in
conjunction with time delay- und throttle valves.

Adjustable parameters
Volume: 0.001 ... 1000 l (1)

Filter

The compressed air filter removes contamination from the com-


pressed air. The size of the filterable particles is dependent upon
the filter class.

Adjustable parameters
Standard nominal flow rate: 0.1 ... 5000 l/min (1000)

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 413
Filter, manual condensate drain

The compressed air filter removes contamination from the com-


pressed air. The size of the filterable particles is dependent upon
the filter class. Condensation, which can occur through sinking
temperatures or the expansion of the compressed air, can be man-
ually drained off.

Adjustable parameters
Standard nominal flow rate: 0.1 ... 5000 l/min (1000)

Filter, automatic condensate drain

The compressed air filter removes contamination from the com-


pressed air. The size of the filterable particles is dependent upon
the filter class. Condensation, which can occur through sinking
temperatures or the expansion of the compressed air, is automati-
cally drained off.

Adjustable parameters
Standard nominal flow rate: 0.1 ... 5000 l/min (1000)

Water separator

The water separator drains off accrued water.

Adjustable parameters
Standard nominal flow rate: 0.1 ... 5000 l/min (1000)

414 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Water separator, automatic condensate drain

The water separator drains off accrued water and is automatically


emptied.

Adjustable parameters
Standard nominal flow rate: 0.1 ... 5000 l/min (1000)

Lubricator

The lubricator enriches the compressed air with oil.

Adjustable parameters
Standard nominal flow rate: 0.1 ... 5000 l/min (1000)

Cooler

The cooler cools the compressed air.

Adjustable parameters
Standard nominal flow rate: 0.1 ... 5000 l/min (1000)

Adsorption dryer

The adsorption dryer reduces the humidity in the compressed air.

Adjustable parameters
Standard nominal flow rate: 0.1 ... 5000 l/min (1000)

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 415
Connection (pneumatic)

A pneumatic connection is a place where a pneumatic line can be


attached to. To simplify the line drawing process, a connection
appears as a small circle in Edit Mode. Pneumatic connections can
be shut by means of a blind plug. An open pneumatic connection
may result in leaking air; FluidSIM thus pops up a warning mes-
sage, if some pneumatic connection was left open. Note that at
each pneumatic connection values for the flow and pressure can be
displayed.

Line (pneumatic)

A pneumatic line is used to connect two pneumatic connectors.


These may be either a simple pneumatic connection or a T-junction.
A pneumatic line is normally treated as an ideal connection, with no
pressure drop being included in the simulation. A frictional loss
can be entered via the Physical model options. If you select
Simple resistance, only the Standard nominal flow rate param-
eter will be included in the simulation. If you select Empirical
model, an empirical model is applied that utilizes the length and
inner diameter.

Adjustable parameters
Physical model: Ideal connection,Simple resistance, Empirical
model (Ideal connection)
Length: 0.01 ... 1000 m (0.5)
Inner diameter: 0.1 ... 100 mm (2.5)
Standard nominal flow rate: 0.1 ... 5000 l/min (500)

T-junction (pneumatic)

A T-junction joins up to four pneumatic lines, thus having a single


pressure potential. Note that T-junctions are introduced automati-
cally by FluidSIM when dropping the line drawing cursor onto
another line in Edit Mode.

416 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
21.2.2 Configurable Way Valves

Configurable 2/n way valve

The configurable 2/n way valve is a way valve with two connec-
tions, where both its body elements operation modes are user-
definable.

Additionally, the pneumatic connections can be closed with either


blind plugs or exhausts.

Adjustable parameters
Desired position: 0 ... 4 (0)
Standard nominal flow rate: 0.1 ... 5000 l/min (60)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
air spring left: 0.01 ... 100 cm2 (0.5)
air spring right: 0.01 ... 100 cm2 (0.5)

Configurable 3/n way valve

The configurable 3/n way valve is a way valve with two connec-
tions, where both its body elements operation modes are user-
definable.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 417
Additionally, the pneumatic connections can be closed with either
blind plugs or exhausts.

Adjustable parameters
Desired position: 0 ... 4 (0)
Standard nominal flow rate: 0.1 ... 5000 l/min (60)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
air spring left: 0.01 ... 100 cm2 (0.5)
air spring right: 0.01 ... 100 cm2 (0.5)

Configurable 4/n way valve

The configurable 4/n way valve is a way valve with two connec-
tions, where both its body elements operation modes are user-
definable.

Additionally, the pneumatic connections can be closed with either


blind plugs or exhausts.

Adjustable parameters
Desired position: 0 ... 4 (0)
Standard nominal flow rate: 0.1 ... 5000 l/min (60)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)

418 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
air spring left: 0.01 ... 100 cm2 (0.5)
air spring right: 0.01 ... 100 cm2 (0.5)

Configurable 5/n way valve

The configurable 5/n way valve is a way valve with two connec-
tions, where both its body elements operation modes are user-
definable.

Additionally, the pneumatic connections can be closed with either


blind plugs or exhausts.

Adjustable parameters
Desired position: 0 ... 4 (0)
Standard nominal flow rate: 0.1 ... 5000 l/min (60)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
air spring left: 0.01 ... 100 cm2 (0.5)

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 419
air spring right: 0.01 ... 100 cm2 (0.5)

Configurable 6/n way valve

The configurable 6/n way valve is a way valve with two connec-
tions, where both its body elements operation modes are user-
definable.

Additionally, the pneumatic connections can be closed with either


blind plugs or exhausts.

Adjustable parameters
Desired position: 0 ... 4 (0)
Standard nominal flow rate: 0.1 ... 5000 l/min (60)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
air spring left: 0.01 ... 100 cm2 (0.5)
air spring right: 0.01 ... 100 cm2 (0.5)

Configurable 8/n way valve

The configurable 8/n way valve is a way valve with two connec-
tions, where both its body elements operation modes are user-
definable.

420 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Additionally, the pneumatic connections can be closed with either
blind plugs or exhausts.

Adjustable parameters
Desired position: 0 ... 4 (0)
Standard nominal flow rate: 0.1 ... 5000 l/min (60)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
air spring left: 0.01 ... 100 cm2 (0.5)
air spring right: 0.01 ... 100 cm2 (0.5)

21.2.3 Mechanically Operated Directional Valves

3/2-way roller lever valve, normally closed

The roller lever valve is operated by pressing on the lever, for


example through the use of a switching cam of a cylinder. The flow
passes through from 1 to 2. After releasing the lever, the valve
returns to its initial position through the use of a return spring.
Connection 1 is shut. In the Simulation Mode, the valve can be
switched manually by clicking on the component, thus not requiring
a cylinder to operate the valve. This valve is derived from a config-

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 421
urable 3/n way valve. You find this valve in the component library
Frequently used Way Valves, under the Library menu.

Adjustable parameters
Desired position: 0 ... 4 (0)
Standard nominal flow rate: 0.1 ... 5000 l/min (60)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
air spring left: 0.01 ... 100 cm2 (0.5)
air spring right: 0.01 ... 100 cm2 (0.5)

3/2-way roller lever valve, normally open

The roller lever valve is operated by pressing on the lever, for


example through the use of a switching cam of a cylinder. Connec-
tion 1 is shut. After releasing the lever, the valve returns to its initial
position through the use of a return spring. The flow may pass
through freely from 1 to 2. In the Simulation Mode, the valve can
be switched manually by clicking on the component, thus not
requiring a cylinder to operate the valve. This valve is derived from
a configurable 3/n way valve. You find this valve in the component
library Frequently used Way Valves, under the Library menu.

Adjustable parameters
Desired position: 0 ... 4 (0)
Standard nominal flow rate: 0.1 ... 5000 l/min (60)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)

422 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
air spring left: 0.01 ... 100 cm2 (0.5)
air spring right: 0.01 ... 100 cm2 (0.5)

3/2-way idle return roller valve, normally closed

The idle return roller valve is operated when the roller is driven in a
specific direction by the switching cam of a cylinder. After releasing
the roller, the valve returns to its initial position through the use of
a return spring. Connection 1 is shut. When the roller is driven in
the opposite direction, the valve is not operated. In the Simulation
Mode, the valve can be switched manually by clicking on the com-
ponent, thus not requiring a cylinder to operate the valve. This
valve is derived from a configurable 3/n way valve. You find this
valve in the component library Frequently used Way Valves,
under the Library menu.

Adjustable parameters
Desired position: 0 ... 4 (0)
Standard nominal flow rate: 0.1 ... 5000 l/min (60)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 423
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
air spring left: 0.01 ... 100 cm2 (0.5)
air spring right: 0.01 ... 100 cm2 (0.5)

Pressurizing valve

The pressurizing valve with plunger control is operated by the


surface of the cylinder cam. When the plunger is operated, com-
pressed air flows freely until the nozzle is closed. A signal up to the
level of the boost pressure is assembled at exit connection 2. In
the Simulation Mode, the valve can be switched manually by click-
ing on the component, thus not requiring a cylinder to operate the
valve.

Adjustable parameters
Desired position: 0 ... 4 (0)
Standard nominal flow rate: 0.1 ... 5000 l/min (60)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
air spring left: 0.01 ... 100 cm2 (0.5)
air spring right: 0.01 ... 100 cm2 (0.5)

424 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Pneumatic proximity switch, solenoid operated

A permanent solenoid found on the piston of a cylinder drives this


3/2 pneumatic directional valve and triggers the control signal. The
flow passes freely from 1 to 2. In the Simulation Mode, the valve
can be switched manually by clicking on the component, thus not
requiring a cylinder to operate the valve. This valve is derived from
a configurable 3/n way valve. You find this valve in the component
library Frequently used Way Valves, under the Library menu.

Adjustable parameters
Desired position: 0 ... 4 (0)
Standard nominal flow rate: 0.1 ... 5000 l/min (60)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
air spring left: 0.01 ... 100 cm2 (0.5)
air spring right: 0.01 ... 100 cm2 (0.5)

3/2-way valve with pushbutton, normally closed

Pressing the pushbutton operates the valve. The flow passes freely
from 1 to 2. Releasing the pushbutton allows the valve to return to
its starting position through the use of a return spring. Connection
1 is shut. By holding down the Shift key and simultaneously
clicking on the component with the mouse cursor, FluidSIM keeps
the valve in permanent operating position. Simply clicking on the

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 425
component cancels the operated state and returns the valve to its
starting position. This valve is derived from a configurable 3/n way
valve. You find this valve in the component library Frequently used
Way Valves, under the Library menu.

Adjustable parameters
Desired position: 0 ... 4 (0)
Standard nominal flow rate: 0.1 ... 5000 l/min (60)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
air spring left: 0.01 ... 100 cm2 (0.5)
air spring right: 0.01 ... 100 cm2 (0.5)

3/2-way valve with pushbutton, normally open

Pressing the pushbutton operates the valve. Connection 1 is shut.


Releasing the pushbutton allows the valve to returns to its starting
position through the use of a return spring. The passes freely from
1 to 2. By holding down the Shift key and simultaneously click-
ing on the component with the mouse cursor, FluidSIM keeps the
valve in permanent operating position. Simply clicking on the
component cancels the operated state and returns the valve to its
starting position. This valve is derived from a configurable 3/n way
valve. You find this valve in the component library Frequently used
Way Valves, under the Library menu.

Adjustable parameters

426 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Desired position: 0 ... 4 (0)
Standard nominal flow rate: 0.1 ... 5000 l/min (60)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
air spring left: 0.01 ... 100 cm2 (0.5)
air spring right: 0.01 ... 100 cm2 (0.5)

3/2-way valve with selection switch or striking button

Pressing the red striking button operates the valve. The flow passes
freely from 1 to 2. Releasing the button has no effect; the valve
remains in its operating position. Turning the button to the right
sets the striking button back to its original position and the valve
returns to its starting position through the use of a return spring.
Connection 1 is shut. This valve is derived from a configurable 3/n
way valve. You find this valve in the component library Frequently
used Way Valves, under the Library menu.

Adjustable parameters
Desired position: 0 ... 4 (0)
Standard nominal flow rate: 0.1 ... 5000 l/min (60)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 427
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
air spring left: 0.01 ... 100 cm2 (0.5)
air spring right: 0.01 ... 100 cm2 (0.5)

5/2-way valve, with selection switch

Turning the selection switch operates the valve. The flow passes
freely from 1 to 4. Releasing the switch has no effect; the valve
remains in its operating position. Turning the switch back to its
original position allows the flow to pass freely from 1 to 2. This
valve is derived from a configurable 5/n way valve. You find this
valve in the component library Frequently used Way Valves,
under the Library menu.

Adjustable parameters
Desired position: 0 ... 4 (0)
Standard nominal flow rate: 0.1 ... 5000 l/min (60)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
air spring left: 0.01 ... 100 cm2 (0.5)
air spring right: 0.01 ... 100 cm2 (0.5)

428 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
21.2.4 Solenoid Operated Directional Valves

3/2-way solenoid valve, normally closed

The solenoid valve is controlled by applying a voltage signal at the


solenoid coil. The flow passes freely from 1 to 2. By stopping the
signal the valve is set back to its starting position through the use
of a return spring. Connection 1 is shut. If no signal is applied to the
valve, it can be manually operated. This valve is derived from a
configurable 3/n way valve. You find this valve in the component
library Frequently used Way Valves, under the Library menu.

Adjustable parameters
Desired position: 0 ... 4 (0)
Standard nominal flow rate: 0.1 ... 5000 l/min (60)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
air spring left: 0.01 ... 100 cm2 (0.5)
air spring right: 0.01 ... 100 cm2 (0.5)

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 429
3/2-way solenoid valve, normally open

The solenoid valve is controlled by applying a voltage signal at the


solenoid coil. Connection 1 is shut. By stopping the signal the valve
is set back to its starting position through the use of a return
spring. The flow passes freely from 1 to 2. If no signal is applied to
the valve, it can be manually operated. This valve is derived from a
configurable 3/n way valve. You find this valve in the component
library Frequently used Way Valves, under the Library menu.

Adjustable parameters
Desired position: 0 ... 4 (0)
Standard nominal flow rate: 0.1 ... 5000 l/min (60)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
air spring left: 0.01 ... 100 cm2 (0.5)
air spring right: 0.01 ... 100 cm2 (0.5)

5/2-way solenoid valve

The solenoid valve is controlled by applying a voltage signal at the


solenoid coil. The flow passes freely from 1 to 4. By stopping the
signal the valve is set back to its starting position through the use
of a return spring. The flow passes freely from 1 to 2. If no signal is
applied to the valve, it can be manually operated. This valve is
derived from a configurable 5/n way valve. You find this valve in

430 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
the component library Frequently used Way Valves, under the
Library menu.

Adjustable parameters
Desired position: 0 ... 4 (0)
Standard nominal flow rate: 0.1 ... 5000 l/min (60)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
air spring left: 0.01 ... 100 cm2 (0.5)
air spring right: 0.01 ... 100 cm2 (0.5)

5/2-way solenoid impulse valve

The solenoid valve is controlled by applying a voltage signal at the


solenoid coil (flow passes from 1 to 4) and remains in this operat-
ing position even when the signal is cut off. Only by applying an
opposite signal will the valve return to its starting position (flow
passes freely from 1 to 2). If no signal is applied to the valve, it can
be manually operated. This valve is derived from a configurable
5/n way valve. You find this valve in the component library Fre-
quently used Way Valves, under the Library menu.

Adjustable parameters
Desired position: 0 ... 4 (0)
Standard nominal flow rate: 0.1 ... 5000 l/min (60)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 431
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
air spring left: 0.01 ... 100 cm2 (0.5)
air spring right: 0.01 ... 100 cm2 (0.5)

5/3-way solenoid valve, mid-Position closed

The solenoid valve is controlled by applying a voltage signal at the


solenoid coil (flow passes from 1 to 4 or from 1 to 2). By stopping
the signal the valve is set back to its starting position through the
use of a return spring. Connections 1, 2, and 4 are shut. If no signal
is applied to the valve, it can be manually operated. This valve is
derived from a configurable 5/n way valve. You find this valve in
the component library Frequently used Way Valves, under the
Library menu.

Adjustable parameters
Desired position: 0 ... 4 (0)
Standard nominal flow rate: 0.1 ... 5000 l/min (60)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)

432 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
air spring left: 0.01 ... 100 cm2 (0.5)
air spring right: 0.01 ... 100 cm2 (0.5)

21.2.5 Pneumatically Operated Directional Valves

3/2-way valve, pneumatically operated, normally closed

The pneumatic valve is controlled by applying a pilot pressure at


connection 12. The flow passes freely from 1 to 2. By stopping the
signal the valve is set back to its starting position through the use
of a return spring. Connection 1 is shut. This valve is derived from a
configurable 3/n way valve. You find this valve in the component
library Frequently used Way Valves, under the Library menu.

Adjustable parameters
Desired position: 0 ... 4 (0)
Standard nominal flow rate: 0.1 ... 5000 l/min (60)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
air spring left: 0.01 ... 100 cm2 (0.5)

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 433
air spring right: 0.01 ... 100 cm2 (0.5)

3/2-way valve, pneumatically operated, normally open

The pneumatic valve is controlled by applying a pilot pressure at


connection 10. Connection 1 is shut. By stopping the signal the
valve is set back to its starting position through the use of a return
spring. The flow passes freely from 1 to 2. This valve is derived from
a configurable 3/n way valve. You find this valve in the component
library Frequently used Way Valves, under the Library menu.

Adjustable parameters
Desired position: 0 ... 4 (0)
Standard nominal flow rate: 0.1 ... 5000 l/min (60)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
air spring left: 0.01 ... 100 cm2 (0.5)
air spring right: 0.01 ... 100 cm2 (0.5)

5/2-way valve, pneumatically operated

The pneumatic valve is controlled by applying a pilot pressure at


connection 14. The flow passes freely from 1 to 4. By stopping the
signal the valve is set back to its starting position through the use
of a return spring. The flow passes freely from 1 to 2. This valve is

434 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
derived from a configurable 5/n way valve. You find this valve in
the component library Frequently used Way Valves, under the
Library menu.

Adjustable parameters
Desired position: 0 ... 4 (0)
Standard nominal flow rate: 0.1 ... 5000 l/min (60)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
air spring left: 0.01 ... 100 cm2 (0.5)
air spring right: 0.01 ... 100 cm2 (0.5)

5/2-way impulse valve, pneumatically operated

The pneumatic valve is controlled by applying reciprocal pilot


pressures at connection 14 (flow passes from 1 to 4) and connec-
tion 12 (flow passes from 1 to 2). The valves operating position
remains until an opposite signal is received by the valve. This valve
is derived from a configurable 5/n way valve. You find this valve in
the component library Frequently used Way Valves, under the
Library menu.

Adjustable parameters
Desired position: 0 ... 4 (0)
Standard nominal flow rate: 0.1 ... 5000 l/min (60)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 435
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)
Pilot control right: 0.01 ... 100 cm2 (1)
air spring left: 0.01 ... 100 cm2 (0.5)
air spring right: 0.01 ... 100 cm2 (0.5)

5/3-way pneumatic valve, mid-Position closed

The pneumatic valve is controlled by applying reciprocal pilot


pressures at connection 14 (flow passes from 1 to 4) and connec-
tion 12 (flow passes from 1 to 2). By stopping the signals the valve
is set back to its starting position through the use of a return
spring. Connections 1, 2, and 4 are shut. This valve is derived from
a configurable 5/n way valve. You find this valve in the component
library Frequently used Way Valves, under the Library menu.

Adjustable parameters
Desired position: 0 ... 4 (0)
Standard nominal flow rate: 0.1 ... 5000 l/min (60)
Positioning time: 1e-4 ... 10 s (0.02)
Reset time: 1e-4 ... 10 s (0.03)
Minimum voltage: 0.1 ... 300 V (20)
Electrically left at U_min: 0.01 ... 100 N (70)
Electrically right at U_min: 0.01 ... 100 N (70)
Mechanically left: 0.01 ... 100 N (100)
Mechanically right: 0.01 ... 100 N (100)
Physical spring force: 0.01 ... 100 N (30)
Minimum force: 0.01 ... 100 N (20)
Min. pilot control force: 0.01 ... 100 N (15)
Left: 0.01 ... 100 cm2 (1)
Right: 0.01 ... 100 cm2 (1)
Pilot control left: 0.01 ... 100 cm2 (1)

436 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Pilot control right: 0.01 ... 100 cm2 (1)
air spring left: 0.01 ... 100 cm2 (0.5)
air spring right: 0.01 ... 100 cm2 (0.5)

Low pressure amplifier unit, 2 compartments

Each of the two double-level low pressure amplifier units has the
function of a 3/2 directional valve that is normally closed. The
signal at connection 12 is raised to a higher boost pressure level
through the use of a double-level amplifier and is put out by con-
nection 2.

Adjustable parameters
Standard nominal flow rate: 0.1 ... 5000 l/min (60)

21.2.6 Shutoff Valves and Flow Control Valves

Shuttle valve

The shuttle valve is switched based on the compressed air entering


into either input connection 1 and leaving via an output connection
2. Should both input connections begin receiving compressed air,
the connection with the higher pressure takes precedence and is
put out (OR function).

Adjustable parameters
Standard nominal flow rate: 0.1 ... 5000 l/min (108)

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 437
Quick exhaust valve

The compressed air passes from connection 1 to connection 2. If


the pressure should decrease at connection 1, then the com-
pressed air from connection 2 will escape to the outside via the
installed silencer.

Adjustable parameters
Standard nominal flow rate 1...2: 0.1 ... 5000 l/min (300)
Standard nominal flow rate 2...3: 0.1 ... 5000 l/min (550)

Two pressure valve

The two pressure valve is switched based on the compressed air


entering into both input connections 1 and leaving via an output
connection 2. Should both input connections begin receiving com-
pressed air, the connection with the lower pressure takes prece-
dence and is put out (AND function).

Adjustable parameters
Standard nominal flow rate: 0.1 ... 5000 l/min (550)

Check valve

If the inlet pressure at 1 is higher than the outlet pressure at 2, then


the check valve allows the flow to pass, otherwise it blocks the
flow.

Adjustable parameters
Standard nominal flow rate: 0.1 ... 5000 l/min (108)

438 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Check valve, spring loaded

If the inlet pressure at 1 is higher than the outlet pressure at 2 and


the nominal pressure, then the check valve allows the flow to pass,
otherwise it blocks the flow.

Adjustable parameters
Opening pressure: 0 ... 2 MPa (0.1)
Pressure regulation range: 0.01 ... 1 MPa (0.05)
Standard nominal flow rate: 0.1 ... 5000 l/min (108)

Check valve with pilot control

If the entering pressure at connection 1 is higher that the outgoing


pressure at 2, the check valve allows the flow to pass freely. Other-
wise, the valve stops the flow. Additionally, the check valve can be
opened via the control line 12. This action allows the flow to pass
freely in both directions.

Adjustable parameters
Area ratio: 0.1 ... 10 (3.3)
Standard nominal flow rate: 0.1 ... 5000 l/min (108)

Check valve with pilot control, spring loaded

If the inlet pressure at 1 is higher than the outlet pressure at 2 and


the nominal pressure, then the check valve allows the flow to pass,
otherwise it blocks the flow. Additionally, the check valve can be
released using the pilot line 12, thus enabling the flow in both
directions.

Adjustable parameters
Opening pressure: 0 ... 2 MPa (0.1)
Pressure regulation range: 0.01 ... 1 MPa (0.05)
Area ratio: 0.1 ... 10 (3.3)

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 439
Standard nominal flow rate: 0.1 ... 5000 l/min (108)

Pilot to close check valve

If the inlet pressure at 1 is higher than the outlet pressure at 2, then


the non-return valve allows the flow to pass, otherwise it blocks the
flow. Additionally, the non-return valve can be closed using the
pilot line 10.

Adjustable parameters
Area ratio: 0.1 ... 10 (3.3)
Standard nominal flow rate: 0.1 ... 5000 l/min (108)

Pilot to close check valve, spring loaded

If the inlet pressure at 1 is higher than the outlet pressure at 2 and


the nominal pressure, then the non-return valve allows the flow to
pass, otherwise it blocks the flow. Additionally, the non-return
valve can be closed using the pilot line 10.

Adjustable parameters
Opening pressure: 0 ... 2 MPa (0.1)
Pressure regulation range: 0.01 ... 1 MPa (0.05)
Area ratio: 0.1 ... 10 (3.3)
Standard nominal flow rate: 0.1 ... 5000 l/min (108)

Nozzle

The nozzle represents a pneumatic resistance.

Adjustable parameters
Standard nominal flow rate: 0.1 ... 5000 l/min (100)

440 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Throttle valve

The setting of the throttle valve is set by means of a rotary knob.


Please note that by the rotary knob no absolute resistance value
can be set. This means that, in reality, different throttle valves can
generate different resistance values despite identical settings.

Adjustable parameters
Opening level: 0 ... 100 % (100)
Standard nominal flow rate: 0.1 ... 5000 l/min (100)

Orifice

The orifice represents a pneumatic resistance.

Adjustable parameters
Standard nominal flow rate: 0.1 ... 5000 l/min (100)

Orifice, adjustable

The orifice represents a variable pneumatic resistance.

Adjustable parameters
Opening level: 0 ... 100 % (100)
Standard nominal flow rate: 0.1 ... 5000 l/min (100)

One-way flow control valve

The one-way flow control valve is made up of a throttle valve and a


check valve. The check valve stops the flow from passing in a cer-
tain direction. The flow then passes though the throttle valve. The

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 441
cross-section of the throttle is adjustable via a regular screw. In the
opposite direction the flow can pass through the check valve.

Adjustable parameters
Opening level: 0 ... 100 % (100)
Standard nominal flow rate (Flow control valve): 0.1 ... 5000 l/min
(45)
Standard nominal flow rate (Non-return valve): 0.1 ... 5000 l/min
(65)

Pneumatic counter

The counter registers pneumatic signals starting at a predeter-


mined number and counting backwards. If zero is reached, then the
counter releases an output signal. This output signal continues
until the counter is reset either by hand or from at signal at connec-
tion 10.

Adjustable parameters
Counter: 0 ... 9999 (3)
Standard nominal flow rate: 0.1 ... 5000 l/min (60)

Time delay valve, normally closed

The time delay valve is actuated by a pneumatic signal at port 1


after a preset time delay has elapsed. It is returned to the normal
position via return spring when the signal is removed. The time
delay is infinitely adjustable by means of a regulating screw. The
time delay is reset automatically within 200 ms.

Adjustable parameters
Delay time: 0.1 ... 100 s (3)
Standard nominal flow rate: 0.1 ... 5000 l/min (50)

442 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Time delay valve, normally open

After the pilot signal is applied at port 10, a preset time elapses
before the pneumatic timer is actuated. It returns to its initial
position via a return spring once the signal is removed. The time
delay is infinitely adjustable by means of a regulating screw. The
time delay is reset automatically within 200 ms.

Adjustable parameters
Delay time: 0.1 ... 100 s (3)
Standard nominal flow rate: 0.1 ... 5000 l/min (50)

Ring sensor

The ring sensor is a non-contact pneumatic signal output module. It


is supplied with low pressure at connection 1. If, due to an object,
the entering air flow is disturbed, a low pressure signal will be put
out by connection 2. To simulate an object in the air flow, as pre-
sented above, simply click on the component during FluidSIM
Simulation Mode.

21.2.7 Pressure Operated Switches

2-way pressure regulator valve

The pressure regulator valve regulates the compressed air supply


to the preset nominal pressure and equalizes pressure fluctuations.
The valve closes when the pressure at connection 2 exceeds the
nominal pressure. The setting for the real components is compo-
nent dependent and cannot be changed.

Adjustable parameters

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 443
Nominal pressure: 0 ... 2 MPa (0.4)
Pressure regulation range: 0.01 ... 1 MPa (0.05)
Standard nominal flow rate: 0.1 ... 5000 l/min (300)

2-way pressure regulator valve, adjustable

The pressure regulator valve regulates the compressed air supply


to the preset nominal pressure and equalizes pressure fluctuations.
The valve closes when the pressure at connection 2 exceeds the
nominal pressure.

Adjustable parameters
Nominal pressure: 0 ... 2 MPa (0.4)
Pressure regulation range: 0.01 ... 1 MPa (0.05)
Standard nominal flow rate: 0.1 ... 5000 l/min (300)

Pressure regulator valve with manometer

The pressure control valve regulates the supplied pressure based


on the adjustable operating pressure and the variations in the
pressure. The manometer displays the pressure at connection 2.

Adjustable parameters
Nominal pressure: 0 ... 2 MPa (0.4)
Pressure regulation range: 0.01 ... 1 MPa (0.05)
Standard nominal flow rate: 0.1 ... 5000 l/min (300)

3-way pressure regulator valve

The pressure regulator valve regulates the compressed air supply


to the preset nominal pressure and equalizes pressure fluctuations.
The compressed air is discharged via connection 3 when the pres-
sure at connection 2 exceeds the nominal pressure. The setting for

444 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
the real components is component dependent and cannot be
changed.

Adjustable parameters
Nominal pressure: 0 ... 2 MPa (0.4)
Pressure regulation range: 0.01 ... 1 MPa (0.05)
Standard nominal flow rate: 0.1 ... 5000 l/min (300)

3-way pressure regulator valve, adjustable

The pressure regulator valve regulates the compressed air supply


to the preset nominal pressure and equalizes pressure fluctuations.
The compressed air is discharged via connection 3 when the pres-
sure at connection 2 exceeds the nominal pressure.

Adjustable parameters
Nominal pressure: 0 ... 2 MPa (0.4)
Pressure regulation range: 0.01 ... 1 MPa (0.05)
Standard nominal flow rate: 0.1 ... 5000 l/min (300)

Closing pressure compensator

The pressure compensator represents a pressure dependent


pneumatic resistance. The pressure compensator closes when the
pressure difference p3-p4 exceeds the nominal pressure. A pres-
sure regulating valve is implemented by the combination of connec-
tions 2 and 3. The nominal pressure setting of the real components
is component dependent and cannot be changed.

Adjustable parameters
Nominal pressure: 0 ... 2 MPa (0.4)
Pressure regulation range: 0.01 ... 1 MPa (0.05)
Standard nominal flow rate: 0.1 ... 5000 l/min (300)

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 445
Closing pressure compensator, adjustable

The pressure compensator represents a pressure dependent


pneumatic resistance. The pressure compensator closes when the
pressure difference p3-p4 exceeds the nominal pressure. A pres-
sure regulating valve is implemented by the combination of connec-
tions 2 and 3.

Adjustable parameters
Nominal pressure: 0 ... 2 MPa (0.4)
Pressure regulation range: 0.01 ... 1 MPa (0.05)
Standard nominal flow rate: 0.1 ... 5000 l/min (300)

Opening pressure compensator

The pressure compensator represents a pressure dependent


pneumatic resistance. The pressure compensator opens when the
pressure difference p3-p4 exceeds the nominal pressure. A se-
quence valve is implemented by the combination of connections 1
and 3. The nominal pressure setting of the real components is
component dependent and cannot be changed.

Adjustable parameters
Nominal pressure: 0 ... 2 MPa (0.4)
Pressure regulation range: 0.01 ... 1 MPa (0.05)
Standard nominal flow rate: 0.1 ... 5000 l/min (300)

Opening pressure compensator, adjustable

The pressure compensator represents a pressure dependent


pneumatic resistance. The pressure compensator opens when the
pressure difference p3-p4 exceeds the nominal pressure. A se-
quence valve is implemented by the combination of connections 1
and 3.

446 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Adjustable parameters
Nominal pressure: 0 ... 2 MPa (0.4)
Pressure regulation range: 0.01 ... 1 MPa (0.05)
Standard nominal flow rate: 0.1 ... 5000 l/min (300)

21.2.8 Pressure Operated Switches

Analog pressure sensor

The pressure sensor measures the pressure and operates the


pressure switch when the adjustable switching pressure has been
exceeded.

Adjustable parameters
Switching pressure: -0.1 ... 2 MPa (0.3)
Hysteresis: 0 ... 1 MPa (0)

Vacuum switch

The vacuum switch operates the linked pressure switch, when the
pressure falls below the adjustable switching pressure. If the sym-
bol is used as a pressure switch the respective switch is operated
when the pressure exceeds the switching pressure.

Adjustable parameters
Switching pressure: -0.1 ... 2 MPa (0.3)
Hysteresis: 0 ... 1 MPa (0)

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 447
Differential pressure switch

The differential pressure switch can be employed as a pressure


switch (connection P1), a vacuum switch (connection P2) or as a
differential pressure switch (P1-P2). The respective pneumatic to
electric converter is operated when the difference in pressure
between P1-P2 exceeds the adjustable switching pressure.

Adjustable parameters
Switching pressure: -2 ... 2 MPa (0.3)
Hysteresis: 0 ... 1 MPa (0)

21.2.9 Vacuum Technique

Vacuum suction nozzle

The vacuum suction nozzle creates its vacuum based on the ejector
principle. In this case, compressed air flows from connection 1 to 3,
creating a vacuum at connection 1v. A sucker can be connected to
the vacuum connection 1v. Stopping the input of compressed air at
connection 1 stops any suction also.

Adjustable parameters
Maximum vacuum: -0.999 ... 0 bar (-0.85)
Operating pressure for max. vacuum: 0.1 ... 20 bar (4.25)
Air consumption at 600 kPa: 1 ... 1000 l/min (11.6)
Max. suction rate: 0.1 ... 1000 l/min (6)

448 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Vacuum suction nozzle

The vacuum suction nozzle creates its vacuum based on the ejector
principle. In this case, compressed air flows from connection 1 to 3,
creating a vacuum at connection 1v. A sucker can be connected to
the vacuum connection 1v. Stopping the input of compressed air at
connection 1 stops any suction also.

Adjustable parameters
Maximum vacuum: -0.999 ... 0 bar (-0.85)
Operating pressure for max. vacuum: 0.1 ... 20 bar (4.25)
Air consumption at 600 kPa: 1 ... 1000 l/min (11.6)
Max. suction rate: 0.1 ... 1000 l/min (6)

Single-stage ejector with repulsion mechanism (vacuum genera-


tor)

The vacuum generator functions like the vacuum suction nozzle,


except that an integrated reservoir is filled with air during the
suction process. When the input line is switched off, the com-
pressed air stored in the reservoir discharges in a pulse via the port
(quick exhaust), securely repelling the suctioned workpiece from
the vacuum cup. The volume can be enlarged by means of an
additional port. This additional volume allows the energy of the
vent pulse to be varied as required.

Adjustable parameters
Maximum vacuum: -0.999 ... 0 bar (-0.85)
Operating pressure for max. vacuum: 0.1 ... 20 bar (4.25)
Air consumption at 600 kPa: 1 ... 1000 l/min (11.6)
Max. suction rate: 0.1 ... 1000 l/min (6)
Volume: 0.001 ... 10 l (0.05)

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 449
Suction cup

The suction cup can be used together with the vacuum suction
nozzle to grip objects by suction. Lowering the cup onto an object
is simulated in FluidSIM in Simulation Mode by clicking on the
component. An additional click lifts the suction cup.

Adjustable parameters
Diameter: 1 ... 1000 mm (20)
Load to be lifted: 0.001 ... 1000 kg (0.1)
Safety factor: 0.1 ... 100 (1)

Vacuum security valve

If multiple suction cups are supplied with vacuum by one vacuum


suction nozzle, the vacuum will collapse if one or more cups do not
form a suction grip on the workpiece or workpieces. To prevent
this, so-called vacuum security valves are used. Vacuum security
valves are installed between the vacuum suction nozzle and the
suction cup. If, during vacuum generation, a suction cup is uncov-
ered, or only partly covered, the vacuum security valve automatical-
ly stops the influx of air. If the suction cup is open to the environ-
ment, the float is pressed up against the housing by the vacuum. In
this position, air can only flow through a small hole at the front of
the float, greatly reducing the air flow. If a workpiece comes in
contact with the suction cup, the air flow is reduced and the spring
forces the float downward. The air flow flows around the float, with
the larger opening allowing generation of a complete vacuum in the
suction cup.

Adjustable parameters
Min. spring pressure: 0 ... 1 bar (0.1)
Max. Spring pressure: 0.01 ... 1 bar (0.2)
Min. Flow rate at p1-p2 = 50 kPa: 0.001 ... 1000 l/min (0.5)
Max. Flow rate at p1-p2 = 50 kPa: 0.1 ... 1000 l/min (4)

450 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Adjustable vacuum actuator valve

The vacuum actuator valve is employed through the conversion of a


vacuum signal. As soon as the vacuum reaches the adjustable
value at connection 1v, the attached valve body is switched.

Adjustable parameters
Switching pressure: -0.1 ... 0 MPa (-0.025)
Standard nominal flow rate: 0.1 ... 5000 l/min (100)

21.2.10 Valve Groups

Pressure sequence valve

The sequence valve is operated when the control pressure at con-


nection 12 has been reached. The flow passes freely from 1 to 2.
Removing the signal allows the valve to return to its starting posi-
tion through the use of a return spring. Connection 1 is shut. The
pressure of the control signal is infinitely adjustable via a pressure
setting screw.

Adjustable parameters
Switching pressure: 0 ... 20 bar (3)
Standard nominal flow rate: 0.1 ... 5000 l/min (100)

Time delay valve, normally closed

The time delay valve is made up of a pneumatically operated 3/2-


way valve, a one-way flow control valve, and small air accumulator.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 451
When the necessary pressure is reached at the control connection
12 of the unit, the 3/2-way valve switches and the flow passes
freely from 1 to 2.

Adjustable parameters
Opening level: 0 ... 100 % (100)
Standard nominal flow rate (Flow control valve): 0.1 ... 5000 l/min
(10)
Volume: 0.001 ... 100 l (0.01)
Standard nominal flow rate (Directional valve): 0.1 ... 5000 l/min
(50)

Time delay valve, normally open

The time delay valve is made up of a pneumatically operated 3/2-


way valve, a one-way flow control valve, and small air accumulator.
When the necessary pressure is reached at the control connection
10 of the unit, the 3/2-way valve switches and stops the flow from
passing between 1 and 2.

Adjustable parameters
Opening level: 0 ... 100 % (100)
Standard nominal flow rate (Flow control valve): 0.1 ... 5000 l/min
(10)
Volume: 0.001 ... 100 l (0.01)
Standard nominal flow rate (Directional valve): 0.1 ... 5000 l/min
(50)

Stepper module, type TAA

The stepper module is made up of a memory unit (3/2-way impulse


valve), an AND and an OR component, a viewable announcement,
and an auxiliary manual operation.

Adjustable parameters
Initial Position: Left, Right (Left)
Desired position: 0 ... 2 (0)

452 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Standard nominal flow rate: 0.1 ... 5000 l/min (60)

Stepper module, type TAB

The stepper module is made up of a memory unit (3/2-way impulse


valve), an AND and an OR component, a viewable announcement,
and an auxiliary manual operation.

Adjustable parameters
Initial Position: Left, Right (Right)
Desired position: 0 ... 2 (0)
Standard nominal flow rate: 0.1 ... 5000 l/min (60)

Quickstepper

The Quickstepper is a ready to be fitted, mechanical/pneumatic


control device with 12 in- and outputs. The outputs are successive-
ly synchronized with the input signals.

Control block for two-hand start ZSB

The control block for two-hand start ZSB is a pneumatic AND ele-
ment. If the inputs 11 and 12 are pressurized within max. 0.5 s one
after the other, the ZSB will switch through: an output signal is
present at port 2. Control takes place via two external 3/2-way
pushbutton valves. As long as both pushbutton valves are activat-
ed, outlet port 2 is pressurized. If one or both pushbuttons are
released, outlet port 2 is unpressurized. The system exhausts from
2 to 3.

Adjustable parameters
Opening level: 0 ... 100 % (100)
Standard nominal flow rate: 0.1 ... 5000 l/min (100)

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 453
21.2.11 Continuous valves

5/3-way proportional valve

The proportional valve transforms an analog electrical input signal


into corresponding opening cross-sections at the outputs. At half
nominal voltage i.e. 5 V, the pneumatic mid-position is taken. Here
all leading edges are closed, so that no air flows through the valve.
Beneficial static and dynamic characteristics with minimal hystere-
sis (less than 0,3 %), short actuating time (typically 5 ms), and a
higher upper frequency limit (approx. 100 Hz), are achieved
through an integrated electronic position control for the slide
distance. Thus the valve, as control element and especially in
combination with a higher ranked position controller, is suitable for
the positioning of a pneumatic cylinder.

Adjustable parameters
Standard nominal flow rate: 0.1 ... 5000 l/min (773)

21.2.12 Actuators

Configurable cylinder

The configurable cylinder can be customized via its properties


dialog. Almost any combination of piston type (single-acting, dou-
ble-acting), the specification of the piston rods (double ended, with
magnetic coupling or slide) and the number (none, one, two) is

454 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
possible. An end position cushioning (without, with, adjustable)
can also be defined. FluidSIM automatically adjusts the symbol
according to the preset configuration. In addition, a load to be
moved (including possible static and sliding friction) and a variable
force profile can be defined in the properties dialog. In the compo-
nent library of FluidSIM there are several pre-configured cylinders
that can be inserted in your circuit and directly used. Should no
suitable symbol be available, then simply choose the component
with the most similarity to the required component, open the prop-
erties dialog and adjust the configuration accordingly.

Adjustable parameters
Piston diameter: 1 ... 1000 mm (20)
Piston rod diameter: 0 ... 1000 mm (8)
Piston Position: 0 ... 5000 mm (0)
Maximum stroke: 1 ... 5000 mm (200)
Mounting angle: 0 ... 360 deg (0)
Parameter input: Calculate automatically, Enter manually (Calcu-
late automatically)
Reference pressure: 0.1 ... 20 bar (6)
Reference velocity: 0.1 ... 2 m/s (1)
Friction at dp_ref: 1 ... 5000 N (120)
Break-away force at dp_ref: 1 ... 5000 N (12)
Parameter input: Calculate automatically, Enter manually (Calcu-
late automatically)
Moving mass: 0.01 ... 1000 kg (0.3)
Leakage: 0 ... 10 l/(min.bar) (0)
Spring pressure at x=0: 0 ... 10 MPa (0.5)
Spring pressure at x=x_max: 0 ... 10 MPa (1)
Damping length: 1 ... 100 mm (10)

Single acting cylinder

The piston rod of a single acting cylinder is operated by the input of


compressed air at the front end position. When the compressed air
is shut off, the piston returns to its starting position via a return
spring. The piston of the cylinder contains a permanent solenoid
which can be used to operate a proximity switch.

Adjustable parameters

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 455
Piston diameter: 1 ... 1000 mm (20)
Piston rod diameter: 0 ... 1000 mm (8)
Piston Position: 0 ... 5000 mm (0)
Maximum stroke: 1 ... 5000 mm (200)
Mounting angle: 0 ... 360 deg (0)
Parameter input: Calculate automatically, Enter manually (Calcu-
late automatically)
Reference pressure: 0.1 ... 20 bar (6)
Reference velocity: 0.1 ... 2 m/s (1)
Friction at dp_ref: 1 ... 5000 N (120)
Break-away force at dp_ref: 1 ... 5000 N (12)
Parameter input: Calculate automatically, Enter manually (Calcu-
late automatically)
Moving mass: 0.01 ... 1000 kg (0.3)
Leakage: 0 ... 10 l/(min.bar) (0)
Spring pressure at x=0: 0 ... 10 MPa (0.5)
Spring pressure at x=x_max: 0 ... 10 MPa (1)
Damping length: 1 ... 100 mm (10)

Single acting cylinder with return spring

The piston of the single acting cylinder is extended to its back


position by the input of compressed air. When the compressed air
is switched off, a return spring moves the piston back to its front
position.

Adjustable parameters
Piston diameter: 1 ... 1000 mm (20)
Piston rod diameter: 0 ... 1000 mm (8)
Piston Position: 0 ... 5000 mm (0)
Maximum stroke: 1 ... 5000 mm (200)
Mounting angle: 0 ... 360 deg (0)
Parameter input: Calculate automatically, Enter manually (Calcu-
late automatically)
Reference pressure: 0.1 ... 20 bar (6)
Reference velocity: 0.1 ... 2 m/s (1)
Friction at dp_ref: 1 ... 5000 N (120)
Break-away force at dp_ref: 1 ... 5000 N (12)
Parameter input: Calculate automatically, Enter manually (Calcu-
late automatically)
Moving mass: 0.01 ... 1000 kg (0.3)

456 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Leakage: 0 ... 10 l/(min.bar) (0)
Spring pressure at x=0: 0 ... 10 MPa (0.5)
Spring pressure at x=x_max: 0 ... 10 MPa (1)
Damping length: 1 ... 100 mm (10)

Double acting cylinder

The piston rod of a double acting cylinder is operated by the recip-


rocal input of compressed air at the front and back of the cylinder.
The end position damping is adjustable via two regular screws. The
piston of the cylinder contains a permanent solenoid which can be
used to operate a proximity switch.

Adjustable parameters
Piston diameter: 1 ... 1000 mm (20)
Piston rod diameter: 0 ... 1000 mm (8)
Piston Position: 0 ... 5000 mm (0)
Maximum stroke: 1 ... 5000 mm (200)
Mounting angle: 0 ... 360 deg (0)
Parameter input: Calculate automatically, Enter manually (Calcu-
late automatically)
Reference pressure: 0.1 ... 20 bar (6)
Reference velocity: 0.1 ... 2 m/s (1)
Friction at dp_ref: 1 ... 5000 N (120)
Break-away force at dp_ref: 1 ... 5000 N (12)
Parameter input: Calculate automatically, Enter manually (Calcu-
late automatically)
Moving mass: 0.01 ... 1000 kg (0.3)
Leakage: 0 ... 10 l/(min.bar) (0)
Spring pressure at x=0: 0 ... 10 MPa (0.5)
Spring pressure at x=x_max: 0 ... 10 MPa (1)
Damping length: 1 ... 100 mm (10)

Double acting cylinder with in and out piston rod

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 457
The in and out piston rod of the double acting cylinder is controlled
by alternating the compressed air input. The cushioning can be
adapted with two adjustment screws.

Adjustable parameters
Piston diameter: 1 ... 1000 mm (20)
Piston rod diameter: 0 ... 1000 mm (8)
Piston Position: 0 ... 5000 mm (0)
Maximum stroke: 1 ... 5000 mm (200)
Mounting angle: 0 ... 360 deg (0)
Parameter input: Calculate automatically, Enter manually (Calcu-
late automatically)
Reference pressure: 0.1 ... 20 bar (6)
Reference velocity: 0.1 ... 2 m/s (1)
Friction at dp_ref: 1 ... 5000 N (120)
Break-away force at dp_ref: 1 ... 5000 N (12)
Parameter input: Calculate automatically, Enter manually (Calcu-
late automatically)
Moving mass: 0.01 ... 1000 kg (0.3)
Leakage: 0 ... 10 l/(min.bar) (0)
Spring pressure at x=0: 0 ... 10 MPa (0.5)
Spring pressure at x=x_max: 0 ... 10 MPa (1)
Damping length: 1 ... 100 mm (10)

Double acting cylinder with two in and out piston rods and single
trestle.

This twin cylinder has two in and out piston rods that move in
parallel and that are coupled by a trestle. The construction guaran-
tees minimum torsion when positioning and moving tools or as-
semblies. Moreover, coming along with the same construction
height, the double piston rod conveys the double force as com-
pared to standard cylinders.

Adjustable parameters
Piston diameter: 1 ... 1000 mm (20)
Piston rod diameter: 0 ... 1000 mm (8)
Piston Position: 0 ... 5000 mm (0)
Maximum stroke: 1 ... 5000 mm (200)
Mounting angle: 0 ... 360 deg (0)

458 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Parameter input: Calculate automatically, Enter manually (Calcu-
late automatically)
Reference pressure: 0.1 ... 20 bar (6)
Reference velocity: 0.1 ... 2 m/s (1)
Friction at dp_ref: 1 ... 5000 N (120)
Break-away force at dp_ref: 1 ... 5000 N (12)
Parameter input: Calculate automatically, Enter manually (Calcu-
late automatically)
Moving mass: 0.01 ... 1000 kg (0.3)
Leakage: 0 ... 10 l/(min.bar) (0)
Spring pressure at x=0: 0 ... 10 MPa (0.5)
Spring pressure at x=x_max: 0 ... 10 MPa (1)
Damping length: 1 ... 100 mm (10)

Double acting cylinder with two in and out piston rods and double
trestle.

This twin cylinder has two in and out piston rods that move in
parallel and that are coupled by a double trestle. The construction
guarantees minimum torsion when positioning and moving tools or
assemblies. Moreover, coming along with the same construction
height, the double piston rod conveys the double force as com-
pared to standard cylinders.

Adjustable parameters
Piston diameter: 1 ... 1000 mm (20)
Piston rod diameter: 0 ... 1000 mm (8)
Piston Position: 0 ... 5000 mm (0)
Maximum stroke: 1 ... 5000 mm (200)
Mounting angle: 0 ... 360 deg (0)
Parameter input: Calculate automatically, Enter manually (Calcu-
late automatically)
Reference pressure: 0.1 ... 20 bar (6)
Reference velocity: 0.1 ... 2 m/s (1)
Friction at dp_ref: 1 ... 5000 N (120)
Break-away force at dp_ref: 1 ... 5000 N (12)
Parameter input: Calculate automatically, Enter manually (Calcu-
late automatically)
Moving mass: 0.01 ... 1000 kg (0.3)
Leakage: 0 ... 10 l/(min.bar) (0)
Spring pressure at x=0: 0 ... 10 MPa (0.5)

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 459
Spring pressure at x=x_max: 0 ... 10 MPa (1)
Damping length: 1 ... 100 mm (10)

Multiple position cylinder

By connecting two cylinders of same piston diameter but different


maximum stroke three piston stop positions can be realized. From
the first stop position the third stop can be reached either directly
or via the intermediate stop. Note that the maximum stroke of the
second piston must be larger than the preceding one. When moving
back, an intermediate stop requires a particular control. The shorter
maximum stroke is half of the other maximum stroke.

Adjustable parameters
Piston diameter: 1 ... 1000 mm (20)
Piston rod diameter: 1 ... 1000 mm (8)
Total stroke: 1 ... 2000 mm (200)
Piston Position: 0 ... 2000 mm (0)
Intermediate position: 0 ... 1000 mm (0)
External force: -10000 ... 10000 N (0)

Linear drive with solenoid coupling

The sliding of the piston in the double rod cylinder is controlled by


a reciprocal input of compressed air.

Adjustable parameters
Piston diameter: 1 ... 1000 mm (20)
Piston rod diameter: 0 ... 1000 mm (8)
Piston Position: 0 ... 5000 mm (0)
Maximum stroke: 1 ... 5000 mm (200)
Mounting angle: 0 ... 360 deg (0)
Parameter input: Calculate automatically, Enter manually (Calcu-
late automatically)
Reference pressure: 0.1 ... 20 bar (6)
Reference velocity: 0.1 ... 2 m/s (1)
Friction at dp_ref: 1 ... 5000 N (120)

460 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Break-away force at dp_ref: 1 ... 5000 N (12)
Parameter input: Calculate automatically, Enter manually (Calcu-
late automatically)
Moving mass: 0.01 ... 1000 kg (0.3)
Leakage: 0 ... 10 l/(min.bar) (0)
Spring pressure at x=0: 0 ... 10 MPa (0.5)
Spring pressure at x=x_max: 0 ... 10 MPa (1)
Damping length: 1 ... 100 mm (10)

Pneumatic linear drive with shape-fitting adaptor

The sledge of the double acting cylinder without a piston rod is


controlled by alternating the compressed air input. This type of
linear drive conveys forces by means of a shape-fitting piston-
sledge construction. The slitted cylinder prohibits the torsion of the
slider.

Adjustable parameters
Piston diameter: 1 ... 1000 mm (20)
Piston rod diameter: 0 ... 1000 mm (8)
Piston Position: 0 ... 5000 mm (0)
Maximum stroke: 1 ... 5000 mm (200)
Mounting angle: 0 ... 360 deg (0)
Parameter input: Calculate automatically, Enter manually (Calcu-
late automatically)
Reference pressure: 0.1 ... 20 bar (6)
Reference velocity: 0.1 ... 2 m/s (1)
Friction at dp_ref: 1 ... 5000 N (120)
Break-away force at dp_ref: 1 ... 5000 N (12)
Parameter input: Calculate automatically, Enter manually (Calcu-
late automatically)
Moving mass: 0.01 ... 1000 kg (0.3)
Leakage: 0 ... 10 l/(min.bar) (0)
Spring pressure at x=0: 0 ... 10 MPa (0.5)
Spring pressure at x=x_max: 0 ... 10 MPa (1)
Damping length: 1 ... 100 mm (10)

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 461
Pneumatic linear drive with shape-fitting adaptor

The sledge of the double acting cylinder without a piston rod is


controlled by alternating the compressed air input. This type of
linear drive conveys forces by means of a shape-fitting piston-
sledge construction. The slitted cylinder prohibits the torsion of the
slider.

Adjustable parameters
Piston diameter: 1 ... 1000 mm (20)
Piston rod diameter: 0 ... 1000 mm (8)
Piston Position: 0 ... 5000 mm (0)
Maximum stroke: 1 ... 5000 mm (200)
Mounting angle: 0 ... 360 deg (0)
Parameter input: Calculate automatically, Enter manually (Calcu-
late automatically)
Reference pressure: 0.1 ... 20 bar (6)
Reference velocity: 0.1 ... 2 m/s (1)
Friction at dp_ref: 1 ... 5000 N (120)
Break-away force at dp_ref: 1 ... 5000 N (12)
Parameter input: Calculate automatically, Enter manually (Calcu-
late automatically)
Moving mass: 0.01 ... 1000 kg (0.3)
Leakage: 0 ... 10 l/(min.bar) (0)
Spring pressure at x=0: 0 ... 10 MPa (0.5)
Spring pressure at x=x_max: 0 ... 10 MPa (1)
Damping length: 1 ... 100 mm (10)

Air motor

The air motor transforms pneumatic energy into mechanical energy.

Adjustable parameters
External torque: -1000 ... 1000 N.m (0)
Displacement: 0.001 ... 5 l (0.1)
Friction: 0.001 ... 100 N.m.s/rad (3)
Moment of inertia: 0.0001 ... 10 kg.m2 (0.0001)

462 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Semi-Rotary actuator

The semi-rotary actuator is controlled by a reciprocal input of


compressed air. In the end positions the semi-rotary actuator can
activate switches or valves via labels.

Adjustable parameters
Initial Position: 0 ... 360 deg (0)
Rotation angle (max): 1 ... 360 deg (180)
Displacement: 0.01 ... 1000 l (0.1)
Friction: 0.01 ... 100 N.m.s/rad (0.1)
Moment of inertia: 1e-005 ... 1 kg.m2 (0.0001)
External torque: -1000 ... 1000 N.m (0)

21.2.13 Measuring Instruments

Manometer

The manometer displays the pressure at its connection.

Differential pressure gauge

The differential pressure gauge displays the pressure difference


between the adjacent pressures at the left and the right connection.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 463
Pressure indicator

An optical signal is activated when the pressure at the connection


to the pressure indicator exceeds the preset switching pressure.

Adjustable parameters
Switching pressure: -0.1 ... 2 MPa (0.3)

Pressure sensor, analog

This symbol represents the pneumatic part of the analog pressure


sensor. The analog pressure sensor measures the adjacent pres-
sure and transforms it into a proportional electrical voltage signal.
In the process, only pressures in the specified pressure ranges are
considered. Within this range, the pressure in the voltage range
from 0 V to 10 V is represented, i.e. the minimum pressure delivers
0 V and the maximum pressure 10 V.

Adjustable parameters
Minimum pressure: -2 ... 2 MPa (0)
Maximum pressure: -2 ... 2 MPa (1)
Voltage at p1: -100 ... 100 V (0)
Voltage at p2: -100 ... 100 V (10)

Analog pressure sensor

This symbol represents the pneumatic part of the analog pressure


sensor.

Adjustable parameters
Minimum pressure: -2 ... 2 MPa (0)
Maximum pressure: -2 ... 2 MPa (1)
Voltage at p1: -100 ... 100 V (0)
Voltage at p2: -100 ... 100 V (10)

464 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Flow meter

The flow meter measures the flow rate. Either the current flow or
the total quantity flowed can be displayed. The component image is
automatically adjusted accordingly.

Adjustable parameters
Standard nominal flow rate: 0.1 ... 5000 l/min (100)

Flow meter

The flow meter measures the flow rate. Either the current flow or
the total quantity flowed can be displayed. The component image is
automatically adjusted accordingly.

Adjustable parameters
Standard nominal flow rate: 0.1 ... 5000 l/min (100)

Flow meter, analog

This symbol represents the pneumatic part of the analog flow


meter. The analog flow meter measures the volumetric flow and
transforms it into a proportional electrical voltage signal. In the
process, only flow rates in the specified pressure ranges are con-
sidered. Within this range, the flow rate in the voltage range from 0
V to 10 V is represented, i.e. the minimum volumetric flow delivers
0 V and the maximum volumetric flow 10 V.

Adjustable parameters
Flow Direction: Ignore, Consider (Ignore)
Flow rate (min): -500 ... 500 l/min (0)
Flow rate (max): -500 ... 500 l/min (1000)
Voltage (q1): -100 ... 100 V (0)
Voltage (q2): -100 ... 100 V (10)

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 465
Standard nominal flow rate: 0.1 ... 5000 l/min (2000)

Pressure sensor with switching outputs and display

The pressure sensor is a piezo-resistive relative pressure transduc-


er with integrated amplifier and built-in temperature compensation.
The pressure to be measured is transferred to a piezo-resistive
element via a silicone layer. The signal change generated in the
element is output as a switching signal at the connector plug via an
integrated amplifier.

The pressure sensor has two compressed air connections, each of


which is assigned an independent sensor element. The measured
input values (In A/In B) are output via two configurable switching
outputs (Out A/Out B). The measured pressure is shown numerical-
ly and graphically on the display.

Adjustable parameters
Output function: Make switch,Break switch (Make switch)
Switching function: Threshold value,Window comparator
(Threshold value)
Switching pressure 1: -0.1 ... 2 MPa (0.3)
Switching pressure 2: -0.1 ... 2 MPa (1)
Hysteresis: 0 ... 2 MPa (0)
Minimum voltage: 1 ... 300 V (13)
Idle current (24 V): 1 ... 10000 mA (32)

Pressure sensor with display

The pressure sensor is a piezoresistive relative pressure transducer


with integrated amplifier and built-in temperature compensation.
The pressure to be measured is transferred onto a silicone coated
piezoresistive element. The signal change generated therein is
output as a voltage or switching signal at the connector plug via an
integrated amplifier.

Adjustable parameters

466 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Output function: Make switch,Break switch (Make switch)
Switching function: Threshold value,Window comparator
(Threshold value)
Switching pressure 1: -0.1 ... 2 MPa (0.3)
Switching pressure 2: -0.1 ... 2 MPa (1)
Hysteresis: 0 ... 2 MPa (0)
Minimum pressure: -0.1 ... 2 MPa (0)
Maximum pressure: -0.1 ... 2 MPa (1)
Voltage at p1: -100 ... 100 V (0)
Voltage at p2: -100 ... 100 V (10)
Minimum voltage: 1 ... 300 V (13)
Idle current (24 V): 1 ... 10000 mA (32)

Flow sensor

The flow sensor is used to measure and monitor flow rate and air
consumption values. Measurement is carried out by means of a
thermal procedure, whereby the amount of heat drawn from a
heated surface of the sensor by the medium flowing past it is
calculated. The flow rate or the accumulated air consumption is
based on the amount of heat drawn.

Connection to higher-order systems is established via two switch-


ing outputs (Out A/B) and an analogue output (Out C). Switching
points can be defined for both binary outputs. Switching points are
possible for both switching outputs for measuring the flow rate; a
consumption switching pulse for output A (Out A) is possible for
measuring the accumulated air consumption. The flow rate value is
output via the analogue output. The flow rate or air consumption is
shown on the display.

Adjustable parameters
Output function: Make switch,Break switch (Make switch)
Switching function: Threshold value,Window comparator
(Threshold value)
Switching point 1 (Flow rate): -5000 ... 5000 l/min (10)
Switching point 2 (Flow rate): -5000 ... 5000 l/min (20)
Hysteresis (Flow rate): 0 ... 5000 l/min (0)
Switching point 1 (Volume): 0 ... 100000 l (100)
Switching point 2 (Volume): 0 ... 100000 l (200)

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 467
Hysteresis (Volume): 0 ... 10000 l (0)
Min. Flow rate: -5000 ... 5000 l/min (0)
Max. Flow rate: -5000 ... 5000 l/min (100)
Voltage at q1: -100 ... 100 V (0)
Voltage at q2: -100 ... 100 V (10)
Minimum voltage: 1 ... 300 V (12)
Idle current (24 V): 1 ... 10000 mA (32)

21.3 Electrical Components

21.3.1 Power Supply

Electrical connection 0V

0V connection of the power supply.

Adjustable parameters
Voltage: 0 ... 400 V (0)

Electrical connection 24V

24V connection of the power supply.

Adjustable parameters
Voltage: 0 ... 400 V (24)

468 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Function generator

The function generator is a voltage source that can create constant,


rectangle, sine and triangle signals. The voltage range is restricted
to -10 V to +10 V. The frequency, the amplitude and the Y-offset of
the signal can be set within this range. A voltage profile can be
additionally specified. Data points can be set interactively with a
mouse-click in the relevant graphic field. These can then be com-
bined to a closed polygon. Alternatively, existing data points can be
marked and both numeric values for the time and the correspond-
ing voltage can be entered in the input fields. If the option Loop
is selected, then the voltage profile is started again.

Adjustable parameters
Signal type: Rectangle, Sine, Triangle, Constant, Profile (Sine)
Frequency: 0.01 ... 100000 Hz (1)
Amplitude: 0 ... 400 V (5)
y offset: -100 ... 100 V (0)
Min. Voltage: -400 ... 400 V (-30)
Max. Voltage: -400 ... 400 V (30)

Function generator

The function generator is a voltage source that can create constant,


rectangle, sine and triangle signals. The voltage range is restricted
to -10 V to +10 V. The frequency, the amplitude and the Y-offset of
the signal can be set within this range. A voltage profile can be
additionally specified. Data points can be set interactively with a
mouse-click in the relevant graphic field. These can then be com-
bined to a closed polygon. Alternatively, existing data points can be
marked and both numeric values for the time and the correspond-
ing voltage can be entered in the input fields. If the option Loop
is selected, then the voltage profile is started again.

Adjustable parameters
Signal type: Rectangle, Sine, Triangle, Constant, Profile (Sine)
Frequency: 0.01 ... 100000 Hz (1)
Amplitude: 0 ... 400 V (5)

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 469
y offset: -100 ... 100 V (0)
Min. Voltage: -400 ... 400 V (-30)
Max. Voltage: -400 ... 400 V (30)

Setpoint value card

Voltage profiles in the range -10 V to +10 V can be created using


the setpoint value card. Up to 8 setpoints W1 to W8 can be speci-
fied in the voltage range -10 V to +10 V. The setpoint card requires
a power supply of 24 V. The increase from the current setpoint to
the next setpoint is defined using 4 ramps R1 to R4 with values
between 0 s/V and 10 s/V, i.e. a low ramp value signifies a large
increase, whereas a high ramp value results in a small increase. The
active ramp is defined as follows: R1 by a positive increase of 0 V,
R2 by a negative increase up to 0 V, R3 by a negative increase of 0
V and R4 by a positive increase up to 0 V. Three operating modes
can be selected: Wait for switching time, Advance setpoints
and External control. In operating mode Wait for switching time
the setpoints are sequentially advanced when the preset change
over time has expired. If Advance setpoints is selected then,
upon attaining the active setpoint, the next setpoint is started
without delay. In operating mode External control the selection of
the active setpoint is effected by gating the inputs I1, I2 and I3 with
at least 15 V. The corresponding setpoint is selected by means of
the specified bit table. During the process, the internal switching
time is inactive.

W1: I1=0 I2=0 I3=0


W2: I1=1 I2=0 I3=0
W3: I1=0 I2=1 I3=0
W4: I1=1 I2=1 I3=0
W5: I1=0 I2=0 I3=1
W6: I1=1 I2=0 I3=1
W7: I1=0 I2=1 I3=1
W8: I1=1 I2=1 I3=1

470 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Connection (electrical)

An electric connection is a place where an electric line can be at-


tached to. To simplify the line drawing process, a connection ap-
pears as a small circle in Edit Mode. Note that at each electric
connection values for the voltage and current can be displayed.

Line (electrical)

A electrical line links two electrical connections. Note that a electri-


cal connection may be a simple electrical connection or a T-
junction. A electrical line causes no voltage drop, i. e., it has no
electrical resistance.

T-junction (electrical)

A T-junction joins up to four electrical lines, thus having a single


voltage potential. Note that T-junctions are introduced automatical-
ly by FluidSIM when dropping the line drawing cursor onto another
line in Edit Mode.

21.3.2 Actuators / Signal Devices

DC motor

The DC motor transforms electrical energy into mechanical energy.


DC motors produce the continual rotation through repeated chang-
es in the direction of current. The characteristics of the 24 V DC
motor relate to the motor used by the Festo Didactic conveyor
belts.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 471
Adjustable parameters
External torque: 0 ... 20 N.m (0)
Idle revolution: 10 ... 20000 1/min (75)

Solenoid

The solenoid converts electrical energy into mechanical energy. An


iron core is pulled when a current flows through a coil. The iron
core is returned to its neutral position by a spring after electrical
current to the coil has been switched off. The solenoid can be used
as a gate or a stopper.

Adjustable parameters
Resistance: 1 ... 10000 Ohm (20)

Indicator light

If current flows, the indicator light is displayed in the user-defined


color.

Adjustable parameters
Resistance: 0.01 ... 1E4 Ohm (193.5)
Minimum voltage: 0.1 ... 300 V (5)

Buzzer

If current flows, a flashing ring around the buzzer is shown. Moreo-


ver, if Buzzer is activated in the menu under Options... Sound,
the buzzer is activated if a sound hardware is installed.

Adjustable parameters

472 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Resistance: 0.01 ... 1E4 Ohm (100)
Minimum voltage: 0.1 ... 300 V (5)

21.3.3 Measuring Instruments / Sensors

Voltmeter

With a voltmeter, the voltage between two positions in a circuit can


be measured.

Adjustable parameters
Measure mode: Instantaneous value,Effective (RMS) voltage
(Instantaneous value)
Time interval: 0.001 ... 100 s (0.1)
Resistance: 1E-3 ... 10 MOhm (1)

Ammeter

With an ammeter, the amperage (current strength) of the current


between two positions in a circuit can be measured.

Adjustable parameters
Measure mode: Instantaneous value,Effective (RMS) current
(Instantaneous value)
Time interval: 0.001 ... 100 s (0.1)
Resistance: 1e-006 ... 1 Ohm (1E-6)

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 473
Displacement encoder

The displacement encoder is a slide potentiometer with longitudi-


nal contact and no connecting-rods. It delivers a voltage signal that
is proportional to the pick up position. The pick up position is
determined by the piston stroke. The voltage range, which will
depict the minimal and maximal piston position, can be defined
within the range -10 V to +10 V by the user. The displacement
encoder requires a power supply of at least 13 V.

Adjustable parameters
Voltage (Cylinder retracted): -10 ... 10 V (0)
Voltage (Cylinder extracted): -10 ... 10 V (10)
Minimum voltage: 0.1 ... 300 V (13)
Resistance: 1 ... 10000 Ohm (100)

Pressure sensor, analog

This symbol represents the electrical part of the Analog-pressure


sensor

Pressure sensor, analog

This symbol represents the electrical part of the Analog-pressure


sensor

Flow meter, analog

This symbol represents the electrical part of the Analog-flow meter.

474 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Flow meter, analog

This symbol represents the electrical part of the Analog-flow meter.

Pressure sensor with switching outputs and display (electrical


part)

Pressure sensor with display (electrical part)

Flow sensor (electrical part)

Position transmitter

The position transmitter is used for continuous detection of the


piston position of magnetically sensed drives. The piston position
is sensed without contact (magnetic). The measurement result is
output in the sensing range of 50 mm as a current and voltage
signal via two analogue outputs. A displacement-proportional
output signal is supplied within the sensing range.

Adjustable parameters
Voltage (Cylinder retracted): -100 ... 100 V (2)
Voltage (Cylinder extracted): -100 ... 100 V (10)
Current (Cylinder retracted): -10000 ... 10000 mA (4)
Current (Cylinder extracted): -10000 ... 10000 mA (20)
Minimum voltage: 1 ... 300 V (15)
Idle current (24 V): 1 ... 10000 mA (32)

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 475
Signal converter

The signal converter converts analogue voltage output signals from


a sensor into switching points. It closes or opens one of the two
circuits (Out A, Out B) when the adjustable switching points are
reached. Possible switching functions are threshold value, hystere-
sis or window comparator. The switching characteristic (N/C, N/O)
can also be selected.

Adjustable parameters
Output function: Make switch,Break switch (Make switch)
Switching function: Threshold value,Window comparator
(Threshold value)
Switching point 1: -100 ... 100 V (1)
Switching point 2: -100 ... 100 V (8)
Hysteresis: 0 ... 100 V (0)
Switching time: 1e-5 ... 10 s (0.001)
Minimum voltage: 1 ... 300 V (15)
Idle current (24 V): 1 ... 10000 mA (32)

21.3.4 General Switches

Break switch

General break switch that is tailored depending on the type of


component that actuates it. For example, if the break switch is
linked via a label to a switch-off delay relay, the break switch
changes to a switch-off delay break switch in the circuit diagram.

476 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Make switch

General make switch that is tailored according to the component


that actuates it. For example, if the make switch is linked via a label
to a switch-on delayed relay, the make switch changes to a switch-
on delayed make switch in the circuit diagram.

Changeover switch

General changeover switch that is tailored according to the compo-


nent that actuates it. For example, if the changeover switch is
linked via a label to a switch-on delayed relay, the changeover
switch changes to a changeover switch in the circuit diagram.

21.3.5 Delay Switches

Break switch (switch-on delayed)

Switch with delayed opening after pickup. Switch-on delayed break


switches are created by using a general break switch and setting a
label.

Make switch (switch-on delayed)

Switch with delayed closing after pickup. Switch-on delayed make


switches are created by using a general make switch and setting a
label.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 477
Changeover switch (switch-on delayed)

Changeover switch with delayed changeover after pickup. Switch-


on delayed changeover switches are created by using a general
changeover switch and setting a label.

Break switch (switch-off delayed)

Switch with delayed closing after dropout. Switch-off delayed break


switches are created by using a general break switch and setting a
label.

Make switch (switch-off delayed)

Switch with delayed opening after dropout. Switch-off delayed


make switches are created by using a general make switch and
setting a label.

Changeover switch (switch-off delayed)

Changeover switch with delayed changeover after dropout. Switch-


off delayed changeover switches are created by using a general
changeover switch and setting a label.

478 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
21.3.6 Limit Switches

Limit switch (break)

Switch that is opened by a cam attached to the cylinder rod. The


switch closes immediately when the cam has passed the switch.
Limit switches are created by using a general break switch and
setting a label.

Switch with roll (break)

Switch that is opened by a cam attached to the cylinder rod. The


switch closes immediately when the cam has passed the switch.
Switches with roll are created by using a general break switch,
setting a label and selecting the switch type in the components
properties dialog.

Reed contact (break)

Switch that is opened by a cam attached to the cylinder rod. The


switch closes immediately when the cam has passed the switch.
Reed contacts are created by using a general break switch, setting
a label and selecting the switch type in the components properties
dialog.

Limit switch (make)

Switch that is closed by a cam attached to the cylinder rod. The


switch opens immediately when the cam has passed the switch.
Limit switches are created by using a general make switch and
setting a label.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 479
Switch with roll (make)

Switch that is closed by a cam attached to the cylinder rod. The


switch opens immediately when the cam has passed the switch.
Switches with roll are created by using a general make switch,
setting a label and selecting the switch type in the components
properties dialog.

Reed contact (make)

Switch that is closed by a cam attached to the cylinder rod. The


switch opens immediately when the cam has passed the switch.
Reed contacts are created by using a general make switch, setting a
label and selecting the switch type in the components properties
dialog.

Limit switch (changeover)

Switch that is changed over by a cam attached to the cylinder rod.


The switch changes back immediately when the cam has passed
the switch. Limit switches are created by using a general changeo-
ver switch and setting a label.

Switch with roll (changeover)

Switch that is changed over by a cam attached to the cylinder rod.


The switch changes back immediately when the cam has passed
the switch. Switches with roll are created by using a general
changeover switch, setting a label and selecting the switch type in
the components properties dialog.

480 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Reed contact (changeover)

Switch that is changed over by a cam attached to the cylinder rod.


The switch changes back immediately when the cam has passed
the switch. Reed contacts are created by using a general changeo-
ver switch, setting a label and selecting the switch type in the
components properties dialog.

21.3.7 Manually Operated Switches

Pushbutton (break)

Switch that opens when actuated and closes immediately when


released. In FluidSIM switches can be actuated permanently
(locked) when continuing to hold down the mouse button and
pushing the Shift key. This permanent actuation is released by a
simple click on the component.

Pushbutton (make)

Switch that closes when actuated and opens immediately when


released. In FluidSIM switches can be actuated permanently
(locked) when continuing to hold down the mouse button and
pushing the Shift - key. This permanent actuation is released by
a simple click on the component.

Pushbutton (changeover)

Switch that changes over when actuated and changes back imme-
diately when released. In FluidSIM switches can be actuated per-

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 481
manently (locked) when continuing to hold down the mouse button
and pushing the Shift - key. This permanent actuation is released
by a simple click on the component.

Detent switch (break)

Switch that opens and locks when actuated.

Detent switch (make)

Switch that closes and locks when actuated.

Detent switch (changeover)

Switch that changes over and locks when actuated.

21.3.8 Pressure Switches

Pneumatic to electric converter

The converter produces an electrical signal, if the preset differential


pressure of the differential pressure switch is exceeded.

Pressure switch (break)

Switch that opens when the preset switching pressure of the


pneumatic or hydraulic pressure switch is exceeded. Pressure

482 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
switches are created by using a general break switch and setting a
label.

Pressure switch (make)

The switch closes when the preset switching pressure of the pneu-
matic or hydraulic pressure switch is exceeded. Pressure switches
are created by using a general make switch and setting a label.

Pressure switch (changeover)

The switch changes over when the preset switching pressure of the
pneumatic or hydraulic pressure switch is exceeded. Pressure
switches are created by using a general changeover switch and
setting a label.

Pressure switch

The switch relays an electrical signal when the preset switching


pressure at the pneumatic pressure switch is exceeded.

Pressure switch

The switch relays an electrical signal when the preset switching


pressure at the hydraulic pressure switch is exceeded.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 483
21.3.9 Proximity Switches

Magnetic proximity switch

Switch that closes when a solenoid is brought nearby. In the Simu-


lation Mode the proximity switch can also be actuated by clicking
on it.

Inductive proximity switch

Switch that closes when the induced electro-magnetic field is


changed. In the Simulation Mode the proximity switch can also be
actuated by clicking on it.

Capacitive proximity switch

Switch that closes when its electrostatic field is changed. In the


Simulation Mode the proximity switch can also be actuated by
clicking on it.

Optical proximity switch

Switch that closes when the light barrier is interrupted. In the


Simulation Mode the proximity switch can also be actuated by
clicking on it.

484 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
21.3.10 Relay

Relay

The relay picks up immediately when current is supplied and drops


out immediately when current is removed.

Adjustable parameters
Resistance: 1 ... 10000 Ohm (550)
Minimum voltage: 0.1 ... 300 V (20)

Relay with switch-on delay

The relay picks up after a preset time when current is supplied and
drops out immediately when current is removed.

Adjustable parameters
Delay time: 0 ... 999 s (5)
Resistance: 1 ... 10000 Ohm (550)
Minimum voltage: 0.1 ... 300 V (20)

Relay with switch-off delay

The relay picks up immediately when current is supplied and drops


out after a preset time when current is removed.

Adjustable parameters
Delay time: 0 ... 999 s (5)
Resistance: 1 ... 10000 Ohm (550)
Minimum voltage: 0.1 ... 300 V (20)

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 485
Relay counter

The relay picks up after a predefined number of current pulses


has/have been counted between the connections A1 and A2. If a
potential is supplied between the connections R1 and R2, the
counter is reset to its predefined value. In the Simulation Mode the
relay counter can also be reset by clicking on it.

Adjustable parameters
Counter: 0 ... 9999 (5)
Resistance: 1 ... 10000 Ohm (550)
Minimum voltage: 0.1 ... 300 V (20)

Starting current limiter

The starting current limiter consists essentially of a relay, whose


coil is situated between the connections IN and 0V, and whose
switch contact is situated between the connections 24V and OUT.
An electronic longitudinal controller restricts, with a switched relay
contact, the current flow to the preset value for the specified dura-
tion. The starting current limiter is usually deployed in combination
with the electric motor.

Adjustable parameters
Duration: 1 ... 10000 ms (0.05)
Current limit: 0.01 ... 100 A (2)

486 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
21.3.11 Controller

Comparator

The comparator is a discontinuous (switching) two-step action


controller with differential gap (hysteresis). When activated, it
delivers a predefined voltage signal. The switch-on value for the
activation is defined by nominal value + 1/2 hysteresis and the
switch-off value by nominal value - 1/2 hysteresis. The comparator
requires a power supply of 24 V.

Adjustable parameters
Set value voltage: -300 ... 300 V (5)
Hysteresis: 0 ... 100 V (0)
Minimum voltage: 0.1 ... 300 V (13)
Resistance: 1 ... 10000 Ohm (100)

PID controller

The PID-Controller is a continuous controller consisting of three


control elements: Proportional, Integral and Derivative. The adjust-
able parameters refer to the PID-Controller in the Technology
Package TP111 pneumatic control TP511 hydraulic control from
Festo Didactic. The output voltage restriction can be set within the
range (i) -10 V to + 10 V or (ii) 0 V to +10 V. In the range (i), a ma-
nipulated variable offset from -7 V to + 7 V can be specified, and in
the range (ii) a manipulated variable offset from 1.5 V to 8.5 V can
be specified. The PID-controller requires a power supply of 24 V.

Adjustable parameters
Range selection: -10 .. 10 V,0 .. 10 V (-10 .. 10 V)
Proportional gain: 0 ... 1000 (1)
Integral gain: 0 ... 1000 1/s (0)
Derivation gain: 0 ... 1000 ms (0)
Control quantity offset: -7 ... 7 V (0)

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 487
Status controller

The status controller is especially suitable for controlling pneumatic


positioning circuits. A pneumatic positioning circuit counts to the
controlled systems that can only be unsatisfactorily controlled with
a standard controller. Three parameters can be attributed to the
present status controller: position, speed and acceleration of the
piston. The controller is therefore referred to as a triple loop
controller. Speed and acceleration are not measured with sensors
out of cost reasons. They are calculated by the controller from the
differences in position. The adjustable parameters refer to the
status controller in the Technology Package TP111 Closed-loop
pneumatics TP511 Closed-loop hydraulics from Festo Didactic. The
output voltage restriction can be set within the range (i) -10 V to +
10 V or (ii) 0 V to +10 V. In the range (i), a manipulated variable
offset from -7 V to + 7 V can be specified, and in the range (ii) a
manipulated variable offset from 1.5 V to 8.5 V can be specified.
The status controller requires a power supply of 24 V.

Adjustable parameters
Range selection: -10 .. 10 V,0 .. 10 V (-10 .. 10 V)
Deviation gain: 0 ... 10 (1)
Velocity damping: 0 ... 100 ms (0)
Acceleration damping: 0 ... 10 ms2 (0)
Total gain: 0 ... 1000 (1)
Control quantity offset: -7 ... 7 V (0)

488 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
21.3.12 EasyPort/OPC/DDE Components

FluidSIM Output Port

Communication with the EasyPort-Hardware and other applications


is implemented with the FluidSIM-Output.

FluidSIM Input Port

Communication with the EasyPort-Hardware and other applications


is implemented with the FluidSIM-Input.

FluidSIM Output Port (analog)

Communication with the EasyPort-Hardware and other applications


is implemented with the analog FluidSIM-Output.

FluidSIM Input Port (analog)

Communication with the EasyPort-Hardware and other applications


is implemented with the analog FluidSIM-Input.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 489
Multi-pin plug distributor

Communication with EasyPort hardware, as well as with other


applications, is carried out with the multi-pin plug distributor. The
contacts on the right-hand side (1, 3, 5, 7, 9 and 11) represent the
digital outputs, and the contacts on the left-hand side (0, 2, 4, 6, 8
and 10) the digital inputs. If the Priority for connected hardware
switch is activated, only the input signals from the external sensors
are taken into consideration, if an EasyPort has been connected.

Universal-I/O

The universal input/output-unit is connected with the multi-pin


plug distributor by a label. The component is a input if the label
refers to a input channel of the multi-pin plug distributor. The
component is an output if the label refers to an output channel of
the multi-pin plug distributor. If used as an input the universal I/O-
component is a voltage source. If the correspondent input channel
of the multi-pin plug distributor on high level, the universal I/O-
Component delivers 24 V, otherwise 0V. If used as an output chan-
nel, the universal I/O-component sets the correspondent output
channel of the multi-pin plug distributor on high level, if there is a
higher voltage than 20 V.

490 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
21.4 Electrical Components (American Standard)

21.4.1 Power Supply

Electrical connection 0V (ladder)

0V connection of the power supply.

Adjustable parameters
Voltage: 0 ... 400 V (0)

Electrical connection 24V (ladder)

24V connection of the power supply.

Adjustable parameters
Voltage: 0 ... 400 V (24)

21.4.2 General Switches

Break switch (ladder)

General break switch that is tailored depending on the type of


component that actuates it. For example, if the break switch is

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 491
linked via a label to a switch-off delay relay, the break switch
changes to a switch-off delay break switch in the circuit diagram.

Make switch (ladder)

General make switch that is tailored according to the component


that actuates it. For example, if the make switch is linked via a label
to a switch-on delayed relay, the make switch changes to a switch-
on delayed make switch in the circuit diagram.

21.4.3 Delay Switches

Break switch (switch-on delayed, ladder)

Switch with delayed opening after pickup. Switch-on delayed break


switches are created by using a general break switch and setting a
label.

Make switch (switch-on delayed, ladder)

Switch with delayed closing after pickup. Switch-on delayed make


switches are created by using a general make switch and setting a
label.

Break switch (switch-off delayed, ladder)

Switch with delayed closing after dropout. Switch-off delayed break


switches are created by using a general break switch and setting a
label.

492 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Make switch (switch-off delayed, ladder)

Switch with delayed opening after dropout. Switch-off delayed


make switches are created by using a general make switch and
setting a label.

21.4.4 Limit Switches

Limit switch (break, ladder)

Switch that is opened by a cam attached to the cylinder rod. The


switch closes immediately when the cam has passed the switch.
Limit switches are created by using a general break switch and
setting a label.

Switch with roll (break, ladder)

Switch that is opened by a cam attached to the cylinder rod. The


switch closes immediately when the cam has passed the switch.
Limit switches are created by using a general break switch and
setting a label.

Reed contact (break, ladder)

Switch that is opened by a cam attached to the cylinder rod. The


switch closes immediately when the cam has passed the switch.
Limit switches are created by using a general break switch and
setting a label.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 493
Limit switch (make, ladder)

Switch that is closed by a cam attached to the cylinder rod. The


switch opens immediately when the cam has passed the switch.
Limit switches are created by using a general make switch and
setting a label.

Switch with roll (make, ladder)

Switch that is closed by a cam attached to the cylinder rod. The


switch opens immediately when the cam has passed the switch.
Limit switches are created by using a general make switch and
setting a label.

Reed contact (make, ladder)

Switch that is closed by a cam attached to the cylinder rod. The


switch opens immediately when the cam has passed the switch.
Limit switches are created by using a general make switch and
setting a label.

21.4.5 Manually Operated Switches

Pushbutton (break, ladder)

Switch that opens when actuated and closes immediately when


released. In FluidSIM switches can be actuated permanently
(locked) when continuing to hold down the mouse button and
pushing the Shift key. This permanent actuation is released by a
simple click on the component.

494 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Pushbutton (make, ladder)

Switch that closes when actuated and opens immediately when


released. In FluidSIM switches can be actuated permanently
(locked) when continuing to hold down the mouse button and
pushing the Shift key. This permanent actuation is released by a
simple click on the component.

Pushbutton (changeover, ladder)

Switch that changes over when actuated and changes back imme-
diately when released. In FluidSIM switches can be actuated per-
manently (locked) when continuing to hold down the mouse button
and pushing the Shift key. This permanent actuation is released
by a simple click on the component.

21.4.6 Pressure Switches

Pressure switch (break, ladder)

Switch that opens when the preset switching pressure of the


pneumatic or hydraulic pressure switch is exceeded. Pressure
switches are created by using a general break switch and setting a
label.

Pressure switch (make, ladder)

The switch closes when the preset switching pressure of the pneu-
matic or hydraulic pressure switch is exceeded. Pressure switches
are created by using a general make switch and setting a label.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 495
21.4.7 Relays

Relay

The relay picks up immediately when current is supplied and drops


out immediately when current is removed.

Adjustable parameters
Resistance: 1 ... 10000 Ohm (550)
Minimum voltage: 0.1 ... 300 V (20)

Relay with switch-on delay (ladder)

The relay picks up after a preset time when current is supplied and
drops out immediately when current is removed.

Adjustable parameters
Delay time: 0 ... 999 s (5)
Resistance: 1 ... 10000 Ohm (550)
Minimum voltage: 0.1 ... 300 V (20)

Relay with switch-off delay (ladder)

The relay picks up immediately when current is supplied and drops


out after a preset time when current is removed.

Adjustable parameters
Delay time: 0 ... 999 s (5)
Resistance: 1 ... 10000 Ohm (550)
Minimum voltage: 0.1 ... 300 V (20)

496 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
21.5 Electronic components

21.5.1 Power supply

Constant voltage source

A constant voltage source is an ideal voltage source, which can


maintain a fixed voltage that does not depend on the output cur-
rent or load resistance.

Adjustable parameters
Voltage: 0 ... 400 V (12)

Potential

A potential is an ideal voltage source with a reference point of


ground.

Adjustable parameters
Voltage: -400 ... 400 V (5)

Ground

The ground symbol defines the 0 V reference potential for all signal
and operating voltages.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 497
Three-phase alternator

A three-phase alternator supplies a combined set of three sinusoi-


dal alternating electric voltages. The voltages are phase shifted to
one another.

There are three inductors inside the alternator, spatially off-set by


120. The magnetic field of an evenly rotating permanent magnet
induces three alternating voltages, phase shifted to one another by
120.

Adjustable parameters
Frequency: 0.01 ... 1000 Hz (50)
String voltage: 0 ... 400 V (7)

Connector panel

Simple connector panel

DC power supply

Transformer for transforming alternating voltage into direct voltage.

Terminals 1 and 2 are used for connection to the alternating voltage


source. The desired direct voltage is made available at terminals L+
and L-.

Adjustable parameters
Effective (RMS) voltage (min): 10 ... 400 V (90)
AC Frequency (min): 10 ... 100 Hz (30)
Voltage (DC): 0 ... 400 V (12)
Efficiency: 0.1 ... 1 (0.9)

498 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
DC power supply

Transformer for transforming alternating voltage into direct voltage.

Terminals 1 and 2 are used for connection to the alternating voltage


source. The desired direct voltage is made available at terminals L+
and L-.

L1

Phase conductor which makes a sinusoidal alternating voltage


available with adjustable amplitude, frequency and phase dis-
placement. A phase displacement of 0 is preset as a default value
for L1.

Adjustable parameters
Effective (RMS) voltage: 0 ... 400 V (230)
Frequency: 1 ... 100 Hz (50)
Phase shift: 0 ... 360 deg (0)

L2

Phase conductor which makes a sinusoidal alternating voltage


available with adjustable amplitude, frequency and phase dis-
placement. A phase displacement of 120 is preset as a default
value for L2.

Adjustable parameters
Effective (RMS) voltage: 0 ... 400 V (230)
Frequency: 1 ... 100 Hz (50)
Phase shift: 0 ... 360 deg (120)

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 499
L3

Phase conductor which makes a sinusoidal alternating voltage


available with adjustable amplitude, frequency and phase dis-
placement. A phase displacement of 240 is preset as a default
value for L3.

Adjustable parameters
Effective (RMS) voltage: 0 ... 400 V (230)
Frequency: 1 ... 100 Hz (50)
Phase shift: 0 ... 360 deg (240)

Neutral conductor

PE

Protective earth conductor

21.5.2 Passive components

Resistor

A resistor represents an ideal ohmic resistor.

Adjustable parameters
Resistance: 1e-6 ... 1E8 Ohm (100)

500 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Resistor, temperature-dependent (NTC)

In a temperature-dependent resistor of type NTC, the resistance


value falls as the temperature rises.

Adjustable parameters
Reference Resistance: 1 ... 1E6 Ohm (5208)
Reference temperature: 0 ... 100 C (23)

Resistor, voltage-dependent (varistor, VDR)

A varistor is a voltage-dependent resistor. Resistance decreases


abruptly once a particular voltage threshold is exceeded.

Resistor, light-dependent (LDR)

A light-dependent resistor consists of an amorphous semiconduc-


tor film. As the incidence of light is increased, electrical resistance
is decreased, due to the internal photoelectric effect.

Adjustable parameters
Light intensity: 0 ... 100 % (50)
Min. Resistance: 1 ... 1E6 Ohm (183)
Max. Resistance: 1 ... 1E6 Ohm (34324)

Potentiometer

A potentiometer is an electrical resistance component with me-


chanically adjustable (by means of rotation or sliding) resistance
values. It provides three connectors and is mainly used as a contin-
uously adjustable voltage divider.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 501
Adjustable parameters
Potentiometer position: 0 ... 100 % (0)
Resistance: 1E-4 ... 100000 kOhm (1)

Capacitor

A capacitor is a passive electrical component which is able to store


electric charge (and therefore electric energy.)

The capacitor in its basic configuration consists of two electrically


conductive surfaces, the electrodes. The electrodes are separated
through an insulating material, the so-called dielectric. The separa-
tion of the two electrodes is so narrow, that the electrical forces are
able to act through the insulating material.

If a constant voltage is applied to the connectors of an uncharged


capacitor, a current flows for a short period of time and one of the
electrodes is positively charged, the other one negatively. This
electric charge is retained when the capacitor is disconnected from
the voltage source. If charge resp. electric flow is extracted from the
capacitor, its voltage drops again.

Adjustable parameters
Capacity: 1E-4 ... 1E7 uF (1)

Capacitor, polarized

A capacitor is a passive electrical component which is able to store


electric charge (and therefore electric energy.)

The capacitor in its basic configuration consists of two electrically


conductive surfaces, the electrodes. The electrodes are separated
through an insulating material, the so-called dielectric. The separa-
tion of the two electrodes is so narrow, that the electrical forces are
able to act through the insulating material.

502 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
If a constant voltage is applied to the connectors of an uncharged
capacitor, a current flows for a short period of time and one of the
electrodes is positively charged, the other one negatively. This
electric charge is retained when the capacitor is disconnected from
the voltage source. If charge resp. electric flow is extracted from the
capacitor, its voltage drops again.

In contrast to the non-polarized capacitor, the polarized capacitor is


only suitable for DC and for AC voltage that does not reverse the
capacitors polarity. The advantage of the polarized capacitor is the
much higher capacity for the same form factor compared to non-
polarized capacitors.

Adjustable parameters
Capacity: 1E-4 ... 1E7 uF (1)

Inductor

An inductor is a passive electrical component which is able to


create induction voltage.

An inductor, also called an inductance, in its basic configuration


consists of wire coils. The inductor provides two terminals.

If an inductor is connected to a DC voltage, then an exponentially


increasing current will flow.

Adjustable parameters
Inductance: 1E-3 ... 1E4 mH (100)

Transformer

The transformer consists of two transformer coils. If an alternating


voltage is applied to one transformer coil, an alternating voltage is
induced in the second coil. In the no-load case, the value of the new
voltage when compared to the originally supplied voltage, follows

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 503
the ratio of the number of windings of the corresponding coils to
each other.

Adjustable parameters
Inductance 1: 1E-3 ... 1E4 mH (595)
Inductance 2: 1E-3 ... 1E4 mH (66)
Coupling coefficient: 0 ... 1 (1)

21.5.3 Semiconductor

Diode

A diode allows an electric current to pass in only one direction,


while in the opposite direction it acts as an insulator. Therefore,
diodes have a forward direction and a reverse direction.

Adjustable parameters
Reference voltage: 0.1 ... 100 V (0.7)
Reference current: 1 ... 1000 mA (12.6)
Resistance in series: 0.001 ... 1000 Ohm (0.0341512)
Saturation current: 1e-15 ... 100 A (7.02767e-9)

Light-emitting diode, LED (red)

A light-emitting diode (LED) is a semiconductor component that


emits light and has the electrical characteristics of a diode. If an
electric current is flowing through the diode in forward direction, it
emits light with a wavelength that depends on the semiconductor
material and doping.

504 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
To make the use of the LED as a simple signal indicator easier,
FluidSIM allows setting the color independent of the physical
characteristics.

Adjustable parameters
Reference voltage: 0.1 ... 100 V (2)
Reference current: 1 ... 1000 mA (25)
Resistance in series : 0.001 ... 1000 Ohm (12.5)
Saturation current: 1e-15 ... 100 A (1e-12)

Light-emitting diode, LED (green)

A light-emitting diode (LED) is a semiconductor component that


emits light and has the electrical characteristics of a diode. If an
electric current is flowing through the diode in forward direction, it
emits light with a wavelength that depends on the semiconductor
material and doping.

To make the use of the LED as a simple signal indicator easier,


FluidSIM allows setting the color independent of the physical
characteristics.

Adjustable parameters
Reference voltage: 0.1 ... 100 V (2.2)
Reference current: 1 ... 1000 mA (30)
Resistance in series : 0.001 ... 1000 Ohm (12.5)
Saturation current: 1e-15 ... 100 A (1e-12)

Light-emitting diode, LED (blue)

A light-emitting diode (LED) is a semiconductor component that


emits light and has the electrical characteristics of a diode. If an
electric current is flowing through the diode in forward direction, it
emits light with a wavelength that depends on the semiconductor
material and doping.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 505
To make the use of the LED as a simple signal indicator easier,
FluidSIM allows setting the color independent of the physical
characteristics.

Adjustable parameters
Reference voltage: 0.1 ... 100 V (4)
Reference current: 1 ... 1000 mA (35)
Resistance in series : 0.001 ... 1000 Ohm (12.5)
Saturation current: 1e-15 ... 100 A (1e-12)

Light-emitting diode, LED (green/red)

A light-emitting diode (LED) is a semiconductor component that


emits light and has the electrical characteristics of a diode. If an
electric current is flowing through the diode in forward direction, it
emits light with a wavelength that depends on the semiconductor
material and doping.

In this component, a green and a red LED with opposite polarity are
connected in parallel. Depending on the current direction either the
green or red LED lights up. Connected to alternating current with a
frequency higher than about 30 Hz, the human eye cannot recog-
nize the blinking and it seems as if both LEDs are lit simultaneously.

Adjustable parameters
Reference voltage: 0.1 ... 100 V (2)
Reference current: 1 ... 1000 mA (25)
Resistance in series : 0.001 ... 1000 Ohm (12.5)
Saturation current: 1e-15 ... 100 A (1e-12)

Zener diode

Because of their characteristics, zener diodes are used in numerous


circuitries for stabilizing and limiting electrical voltages. In forward
direction, they behave like normal diodes. In reverse direction,
resistance drops off considerably after the voltage exceeds a cer-

506 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
tain value, the so-called breakdown voltage. The voltage does not
increase by much after that, even if the electric current is increased.

Adjustable parameters
Reference voltage: 0.1 ... 100 V (0.7)
Reference current: 1 ... 10000 mA (9)
Saturation current: 1e-10 ... 100 A (1e-10)
Z-voltage: 0.1 ... 100 V (10)
Current at Z-voltage: 1 ... 10000 mA (15)

NPN transistor

An NPN transistor is a bipolar junction transistor (BJT). It is operat-


ed with an electric current and is used for switching and amplifying
signals without using mechanically moving parts.

There are two types of BJTs: NPN and PNP. The letters indicate the
order and doping type of the layers. Essentially, a BJT constitutes
two p-n junctions connected together in series (like that of a p-n
diode.) The three terminals are called collector (C), base (B) and
emitter (E).

Adjustable parameters
Forward current gain: 0.1 ... 1000 (120)
Reverse current gain: 0.1 ... 1000 (1)
Saturation current: 1e-16 ... 1e-3 A (8.81138e-14)
Forward early voltage: 1 ... 1000 V (64)

PNP transistor

An PNP transistor is a bipolar junction transistor (BJT). It is operated


with an electric current and is used for switching and amplifying
signals without using mechanically moving parts.

There are two types of BJTs: NPN and PNP. The letters indicate the
order and doping type of the layers. Essentially, a BJT constitutes
two p-n junctions connected together in series (like that of a p-n

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 507
diode.) The three terminals are called collector (C), base (B) and
emitter (E).

Adjustable parameters
Forward current gain: 0.1 ... 1000 (230)
Reverse current gain: 0.1 ... 1000 (1)
Saturation current: 1e-16 ... 1e-3 A (8.81138e-14)
Forward early voltage: 1 ... 1000 V (64)

N-channel JFET

A junction gate field-effect transistor (JFET) controls the electrical


current that flows through the channel between the source and
drain terminals, by using a junction between the gate connector
and the channel.

Depending on doping type, JFETs are classified in two types: n-


channel and p-channel JFETs.

Adjustable parameters
Threshold voltage: -20 ... 0 V (-3)
Transconductance parameter: 1e-6 ... 1e-1 A/V2 (1.304e-3)
Channel-length modulation parameter: 1e-6 ... 1e-1 1/V (2.25e-3)

P-channel JFET

A junction gate field-effect transistor (JFET) controls the electrical


current that flows through the channel between the source and
drain terminals, by using a junction between the gate terminal and
the channel.

Depending on doping type, JFETs are classified in two types: n-


channel and p-channel JFETs.

Adjustable parameters
Threshold voltage: 0 ... 20 V (2.5)
Transconductance parameter: 1e-6 ... 1e-1 A/V2 (1.271e-3)

508 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Channel-length modulation parameter: 1e-6 ... 1e-1 1/V (0.04)

N-channel MOSFET-Transistor

A metal-oxide-semiconductor field-effect transistor (MOSFET) is an


active component with at least three terminals (electrodes): G
(gate), D (drain) and S (source.) In some designs, an additional B
(bulk) terminal is fed to the outside. Usually though, B is connected
internally with S.

Like other field-effect transistors, a MOSFET acts as a voltage-


controlled resistor, meaning that the voltage between gate and
source can be used to change the resistance (and thus the electri-
cal current) between drain and source by several orders of magni-
tude.

Depending on doping type, MOSFETs are classified in two types: n-


channel and p-channel MOSFETs.

P-channel MOSFET

A metal-oxide-semiconductor field-effect transistor (MOSFET) is an


active component with at least three terminals (electrodes): G
(gate), D (drain) and S (source.) In some designs, an additional B
(bulk) terminal is fed to the outside. Usually though, B is connected
internally with S.

Like other field-effect transistors, a MOSFET acts as a voltage-


controlled resistor, meaning that the voltage between gate and
source can be used to change the resistance (and thus the electri-
cal current) between drain and source by several orders of magni-
tude.

Depending on doping type, MOSFETs are classified in two types: n-


channel and p-channel MOSFETs.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 509
Unijunction transistor

Similar to a normal bipolar transistor, a unijunction transistor (UJT)


provides three terminals. Unlike a bipolar transistor however, but
similar to a diode, there is only one p-n junction. In practice, it acts
like a controlled diode that, despite the constant polarity of the
applied voltage, can be made conductive or non-conductive. Be-
cause of the two B terminals, the UJT is also called double-base
diode.

If a small, positive control voltage against B1 is applied to the


emitter, nothing happens at first. If the control voltage is raised
further and a certain potential is reached, the UEB1 voltage will
collapse abruptly, and at the same time the emitter current will
jump to a certain value. In a sense, the UJT has been fired. This
behavior is very similar to a thyristor. A UJT is cleared when the
emitter current falls below a certain threshold.

Thyristor

A thyristor is a semiconductor component built from four or more


semiconductor films of varying levels of doping. Thyristors are
switchable components, meaning they are non-conductive in their
initial state and can be switched on through a small gate current.
After a thyristor has been switched on, it remains conductive even if
there is no gate current. A thyristor can be switched off by falling
below a minimum current, the so-called holding current.

DIAC

A DIAC (diode for alternating current) is an electronic component


with only two terminals. DIACs are also referred to as symmetrical
trigger diodes. The junction between the terminals only becomes
conductive after a breakover voltage has been reached.

The DIACs bidirectional layout allows for the switching of alternat-


ing voltages. As soon as the voltage on the terminals (A1 and A2)

510 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
rises above a certain threshold voltage, it will switch through and
the p-n junction becomes conductive. Resistance will rise rapidly
again after the current that is flowing through the DIAC falls below a
certain value (the holding current.) This procedure is referred to as
resetting the DIAC.

TRIAC

In principle, A TRIAC (triode for alternating current) represents an


inverse-parallel connection of two thyristors. This allows for switch-
ing of alternating current, while a single thyristor can switch in only
one direction and thus acts - in its on-state - like a diode.

A TRIAC has a control terminal G (gate) and two main terminals MT1
and MT2, where MT2 is usually directly connected to the casing. In
order to be able to use a single control terminal for both thyristors,
TRIACs contain two firing, or helper, thyristor junctions, so that it
can be flipped into the low-impedance state by using a positive and
negative control pulse.

21.5.4 Measuring instruments / Sensors

Ohmmeter

An ohmmeter is an electrical test instrument which is used to


measure the electrical resistance of components.

Adjustable parameters
Voltage: 0.1 ... 9 V (9)
Series resistor: 1 ... 1000 kOhm (47)

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 511
Oscilloscope

An oscilloscope is an electronic test instrument that allows visual


observation of one or more electrical voltages and their change
over time on a display device. The oscilloscope displays a history
graph, usually as a two-dimensional graph, where the horizontal x-
axis represents time and the vertical y-axis the voltages that are to
be displayed. The resulting image is called an oscillogram.

Adjustable parameters
Resistance: 1E-3 ... 10 MOhm (10)

Power factor meter

Effective power factor is measured in AC circuits with the power


factor meter. The measuring instrument is equipped with a current
path (terminals 1 and 3) and a voltage path (terminals 4 and 2).
Connect the measuring instruments current path like an ammeter
and the voltage path like a voltmeter.

Adjustable parameters
Time interval: 0.001 ... 100 s (0.1)

Wattmeter

The wattmeter is used to measure effective power in electric cir-


cuits. Its equipped with a current path (terminals 1 and 3) and a
voltage path (terminals 4 and 2). The wattmeter multiplies meas-
ured values for voltage and current with each other and displays
the result. Connect the measuring instruments current path like an
ammeter and the voltage path like a voltmeter.

Apparent power, reactive power and power factor can be measured


with this wattmeter in addition to effective power.

512 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Adjustable parameters
Time interval: 0.001 ... 100 s (0.1)

21.5.5 Switches

Circuit breaker

Circuit breakers protect connected circuits from overloading.


Theyre equipped with a thermal trigger and an electromagnetic
trigger. The thermal trigger is usually a bimetallic switch which is
tripped after a specified period of time when current flowing
through the circuit breaker is greater than nominal current. In the
event of a short-circuit or excessive overcurrent, the electromagnet-
ic trigger is tripped and the circuit break opens very quickly. The
circuit breaker is equipped with trip-free release, which means that
it opens even if its held closed manually. The switchs character-
istic can be selected under the circuit breakers attributes. If char-
acteristic B is selected, the electromagnetic trigger is tripped at an
amperage of 3 times nominal current, or at 5 times nominal current
if characteristic C is selected. For thermal triggering, a selected
tripping point can be specified for a given overcurrent value.

The symbol for the circuit breaker shows the switch in its open
state. The circuit breaker is closed automatically when simulation
in FluidSIM is started, so that it doesnt have to be closed manually
for each simulation.

Adjustable parameters
Rated current: 0.1 ... 100 A (10)
Tripping characteristic: B,C (B)
Tripping temperature: 50 ... 150 C (80)
Multiple of nominal current: 1.5 ... 10 (2)
Tripping time: 0.1 ... 100 s (30)

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 513
3-pole circuit breaker

Circuit breakers protect connected circuits from overloading.


Theyre equipped with a thermal trigger and an electromagnetic
trigger. The thermal trigger is usually a bimetallic switch which is
tripped after a specified period of time when current flowing
through the circuit breaker is greater than nominal current. In the
event of a short-circuit or excessive overcurrent, the electromagnet-
ic trigger is tripped and the circuit break opens very quickly. The
circuit breaker is equipped with trip-free release, which means that
it opens even if its held closed manually.

In the case of this 3-phase circuit breaker, each phase is monitored


separately. If overloading occurs in any single phase, all three
phases are interrupted. The switchs characteristic can be se-
lected under the circuit breakers attributes. If characteristic B is
selected, the electromagnetic trigger is tripped at an amperage of 3
times nominal current, or at 5 times nominal current if characteris-
tic C is selected. For thermal triggering, a selected tripping point
can be specified for a given overcurrent value.

The symbol for the circuit breaker shows the switch in its open
state. The circuit breaker is closed automatically when simulation
in FluidSIM is started, so that it doesnt have to be closed manually
for each simulation.

Adjustable parameters
Rated current: 0.1 ... 100 A (10)
Tripping characteristic: B,C (B)
Tripping temperature: 50 ... 150 C (80)
Multiple of nominal current: 1.5 ... 10 (2)
Tripping time: 0.1 ... 100 s (30)

Motor circuit breaker

Motor circuit breaker are used to protect connected motors against


overloading. Theyre equipped with a thermal trigger for minimal
overcurrent and an electromagnetic trigger for short-circuits. This

514 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
motor circuit breaker has a 10 A tripping class. The thermal trigger
starts to trip as of an amperage of 1.2 times nominal current and
the electromagnetic trigger is tripped as of 7.2 times nominal
current. If overloading occurs in any single phase, all three phases
are interrupted when the circuit breaker is tripped. The circuit
breaker has to be closed manually after tripping.

The symbol for the motor circuit breaker shows the switch in its
open state. The circuit breaker is closed automatically when simu-
lation in FluidSIM is started, so that it doesnt have to be closed
manually for each simulation.

Adjustable parameters
Rated current: 0.1 ... 100 A (3)
Tripping temperature: 50 ... 150 C (80)

Motor protection relay

Motor protection relays are used to protect connected motors


against overloading. If overloading occurs in any of the three con-
nected phases, a connected switch can be actuated by means of
the motor protection relay. In the event of overloading, power
supply to the motor is usually interrupted via the its control circuit.

Adjustable parameters
Rated current: 0.1 ... 100 A (1)
Tripping temperature: 50 ... 150 C (80)

PNOZ safety relay

Safety switching devices are essential constituents of safety tech-


nology. This safety relay with positively driven contacts is used for
the implementation of safety functions such as emergency stop or
the monitoring of safety doors.

This type of safety relay is based on the safety switching device for
the emergency stop function and the safety door in Festo Didactics

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 515
equipment set TP 250, Safety in pneumatic systems. The PNOZ
S4 safety relay from Pilz is used in the equipment set. Correct
wiring of the safety switching device is described in the operating
instructions included with the PNOZ S4.

Adjustable parameters
Operating mode: Automatic/Manual start,Monitored reset with
falling edge,Monitored reset with rising edge (Automatic/Manual
start)
Min. Voltage: 0.1 ... 100 V (21.6)

21.5.6 Machines

Capacitor motor

The capacitor motor is a machine for converting electrical energy


into mechanical energy (rotary motion). Capacitor motors are
single-phase AC motors with squirrel-cage rotor. The rotary field in
the stator is generated with the help of an additional capacitor,
from which the name capacitor motor originates. In order to
improve starting torque, a starter capacitor is used in addition to
the operating capacitor. The capacitance of the starter and operat-
ing capacitors can be adjusted, and direction of rotation can be
selected. The Revolution (Switch) parameter indicates as of which
speed switching from the starter capacitor to the operating capaci-
tor takes place.

Terminal 1 and 2 are used to connected the alternating current


required to operate the motor. Terminal 3 is a rotary terminal
mechanism. A motor test bench or a further motor can be connect-
ed here, for example. (The direction of rotation is usually reversed
via the connection. This can be selected with the connecting cable.)

516 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
The capacitor motors characteristic data (for example winding
resistances, inductances, number of pole pairs etc.) are automati-
cally ascertained in the background after entering the performance
data. Details can be found in the following separate section: Simu-
lation of rotating machines.

Adjustable parameters
Power: 0.001 ... 100 kW (0.25)
Revolution: 1 ... 30000 1/min (1400)
Voltage: 1 ... 10000 V (230)
Frequency: 30 ... 100 Hz (50)
Current: 0.1 ... 100 A (1.86)
Capacity (Starting capacitor): 0.1 ... 100 uF (25)
Capacity (Running capacitor): 0.1 ... 100 uF (10)
Direction of rotation: Left,Right (Right)
External torque: 0 ... 100 N.m (0)
Revolution (Switch): 1 ... 100000 1/min (1000)

Capacitor motor

The capacitor motor is a machine for converting electrical energy


into mechanical energy (rotary motion). Capacitor motors are
single-phase AC motors with squirrel-cage rotor. The rotary field in
the stator is generated with the help of an additional capacitor,
from which the name capacitor motor originates. In order to
improve starting torque, a starter capacitor is used in addition to
the operating capacitor. The capacitance of the starter and operat-
ing capacitors can be adjusted, and direction of rotation can be
selected. The Revolution (Switch) parameter indicates as of which
speed switching from the starter capacitor to the operating capaci-
tor takes place.

The exploded view of the motor makes it possible to manually wire


the stator coils and the capacitors to operating voltage.

Terminals 1 and 2 make reference to the operating capacitor. Ter-


minals 3 and 4 make reference to the starter capacitor including a
centrifugal switch, which opens when a specified speed is exceed-
ed (parameter: Revolution (Switch)). Terminal 5 is a rotary terminal
mechanism. A motor test bench or a further motor can be connect-

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 517
ed here, for example. (The direction of rotation is usually reversed
via the connection. This can be selected with the connecting cable.)

The capacitor motors characteristic data (for example winding


resistances, inductances, number of pole pairs etc.) are automati-
cally ascertained in the background after entering the performance
data. Details can be found in the following separate section: Simu-
lation of rotating machines.

Adjustable parameters
Power: 0.001 ... 100 kW (0.25)
Revolution: 1 ... 30000 1/min (1400)
Voltage: 1 ... 10000 V (230)
Frequency: 30 ... 100 Hz (50)
Current: 0.1 ... 100 A (1.86)
Capacity (Starting capacitor): 0.1 ... 100 uF (25)
Capacity (Running capacitor): 0.1 ... 100 uF (10)
External torque: 0 ... 100 N.m (0)
Revolution (Switch): 1 ... 100000 1/min (1000)

3-phase squirrel-cage asynchronous motor

The 3-phase asynchronous motor is a machine for converting


electrical energy into mechanical energy (rotary motion). Its a
widely used type of induction motor which is simple, rugged and
maintenance-free. It uses a short-circuited rotor and rotor current is
generated by means of induction. Asynchronous motors are used in
particular as high-performance servo-drives. The stator includes
three windings, each of which is arranged at an angle 120 to the
next. A slotted, laminated rotor core is used. A cage made of die-
cast aluminum is inserted into the slots. The cage thus comprises a
system of short-circuited electrical conductors.

The three phases of the 3-phase current are connected to terminal


1 through 3. Terminal 4 is a rotary terminal mechanism. A motor
test bench or a further motor can be connected here, for example.
(The direction of rotation is usually reversed via the connection.
This can be selected with the connecting cable.)

518 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
The inner wiring selected in the parameters determines how en-
tered machine performance data is interpreted in order to ascertain
the machines characteristics data such as winding resistances,
inductances, number of pole pairs etc. These characteristic ma-
chine data are ascertained automatically in the background after
the performance data have been entered. Details can be found in
the following separate section: Simulation of rotating machines. In
addition to the performance data, tightening torque and pull-out
torque can also be entered to the parameters as a ratio to nominal
torque. This makes it possible to specify the characteristic load
curve of an actual machine somewhat more accurately.

Adjustable parameters
Internal wiring: Star connection,Delta connection (Star connec-
tion)
Power: 0.001 ... 1000 kW (0.25)
Revolution: 1 ... 10000 1/min (1350)
Power factor cos : 0.1 ... 0.99 (0.78)
Line-to-line voltage: 1 ... 10000 V (400)
Phase current: 0.1 ... 100 A (0.77)
Frequency: 30 ... 100 Hz (50)
T_0 : T_N: 0.1 ... 10 (1.35)
T_B : T_N: 0.1 ... 10 (1.58)
External torque: 0 ... 100 N.m (0)

3-phase squirrel-cage asynchronous motor

The 3-phase asynchronous motor is a machine for converting


electrical energy into mechanical energy (rotary motion). Its a
widely used type of induction motor which is simple, rugged and
maintenance-free. It uses a short-circuited rotor and rotor current is
generated by means of induction. Asynchronous motors are used in
particular as high-performance servo-drives. The stator includes
three windings, each of which is arranged at an angle 120 to the
next. A slotted, laminated rotor core is used. A cage made of die-
cast aluminum is inserted into the slots. The cage thus comprises a
system of short-circuited electrical conductors.

The three phases of the 3-phase current are connected to terminal


1 through 3. Terminal 4 is a rotary terminal mechanism. A motor

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 519
test bench or a further motor can be connected here, for example.
(The direction of rotation is usually reversed via the connection.
This can be selected with the connecting cable.) The other electrical
terminals are used for connection to the electrical section of the
motor test bench.

The inner wiring selected in the parameters determines how en-


tered machine performance data is interpreted in order to ascertain
the machines characteristics data such as winding resistances,
inductances, number of pole pairs etc. These characteristic ma-
chine data are ascertained automatically in the background after
the performance data have been entered. Details can be found in
the following separate section: Simulation of rotating machines. In
addition to the performance data, tightening torque and pull-out
torque can also be entered to the parameters as a ratio to nominal
torque. This makes it possible to specify the characteristic load
curve of an actual machine somewhat more accurately.

Adjustable parameters
Internal wiring: Star connection,Delta connection (Star connec-
tion)
Power: 0.001 ... 1000 kW (0.25)
Revolution: 1 ... 10000 1/min (1350)
Power factor cos : 0.1 ... 0.99 (0.78)
Line-to-line voltage: 1 ... 10000 V (400)
Phase current: 0.1 ... 100 A (0.77)
Frequency: 30 ... 100 Hz (50)
T_0 : T_N: 0.1 ... 10 (1.35)
T_B : T_N: 0.1 ... 10 (1.58)
External torque: -0 ... 100 N.m (0)

3-phase squirrel-cage asynchronous motor

The 3-phase asynchronous motor is a machine for converting


electrical energy into mechanical energy (rotary motion). Its a
widely used type of induction motor which is simple, rugged and
maintenance-free. It uses a short-circuited rotor and rotor current is
generated by means of induction. Asynchronous motors are used in
particular as high-performance servo-drives. The stator includes
three windings, each of which is arranged at an angle 120 to the

520 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
next. A slotted, laminated rotor core is used. A cage made of die-
cast aluminum is inserted into the slots. The cage thus comprises a
system of short-circuited electrical conductors.

In this representation of the 3-phase motor, the terminals for the


stator windings (U1-U2, V1-V2, W1-W2) are led to the outside. In
this way, the desired wiring of the windings with star or delta con-
nection can be completed from the outside. Terminal 1 is a rotary
terminal mechanism. A motor test bench or a further motor can be
connected here, for example. (The direction of rotation is usually
reversed via the connection. This can be selected with the connect-
ing cable.)

The inner wiring selected in the parameters determines how en-


tered machine performance data is interpreted in order to ascertain
the machines characteristics data such as winding resistances,
inductances, number of pole pairs etc. These characteristic ma-
chine data are ascertained automatically in the background after
the performance data have been entered. Details can be found in
the following separate section: Simulation of rotating machines. In
addition to the performance data, tightening torque and pull-out
torque can also be entered to the parameters as a ratio to nominal
torque. This makes it possible to specify the characteristic load
curve of an actual machine somewhat more accurately.

Adjustable parameters
Internal wiring: Star connection,Delta connection (Star connec-
tion)
Power: 0.001 ... 1000 kW (0.25)
Revolution: 1 ... 10000 1/min (1350)
Power factor cos : 0.1 ... 0.99 (0.78)
Line-to-line voltage: 1 ... 10000 V (400)
Phase current: 0.1 ... 100 A (0.77)
Frequency: 30 ... 100 Hz (50)
T_0 : T_N: 0.1 ... 10 (1.35)
T_B : T_N: 0.1 ... 10 (1.58)
External torque: 0 ... 100 N.m (0)

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 521
3-phase squirrel-cage asynchronous motor

The 3-phase asynchronous motor is a machine for converting


electrical energy into mechanical energy (rotary motion). Its a
widely used type of induction motor which is simple, rugged and
maintenance-free. It uses a short-circuited rotor and rotor current is
generated by means of induction. Asynchronous motors are used in
particular as high-performance servo-drives. The stator includes
three windings, each of which is arranged at an angle 120 to the
next. A slotted, laminated rotor core is used. A cage made of die-
cast aluminum is inserted into the slots. The cage thus comprises a
system of short-circuited electrical conductors.

The three phases of the 3-phase current are connected to terminal


1 through 3. Terminal 4 is a rotary terminal mechanism. A motor
test bench or a further motor can be connected here, for example.
(The direction of rotation is usually reversed via the connection.
This can be selected with the connecting cable.)

The inner wiring selected in the parameters determines how en-


tered machine performance data is interpreted in order to ascertain
the machines characteristics data such as winding resistances,
inductances, number of pole pairs etc. These characteristic ma-
chine data are ascertained automatically in the background after
the performance data have been entered. Details can be found in
the following separate section: Simulation of rotating machines. In
addition to the performance data, tightening torque and pull-out
torque can also be entered to the parameters as a ratio to nominal
torque. This makes it possible to specify the characteristic load
curve of an actual machine somewhat more accurately.

Adjustable parameters
Internal wiring: Star connection,Delta connection (Star connec-
tion)
Power: 0.001 ... 1000 kW (0.25)
Revolution: 1 ... 10000 1/min (1350)
Power factor cos : 0.1 ... 0.99 (0.78)
Line-to-line voltage: 1 ... 10000 V (400)
Phase current: 0.1 ... 100 A (0.77)
Frequency: 30 ... 100 Hz (50)
T_0 : T_N: 0.1 ... 10 (1.35)

522 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
T_B : T_N: 0.1 ... 10 (1.58)
External torque: 0 ... 100 N.m (0)

Synchronous motor

The synchronous motor is a machine for converting electrical ener-


gy into mechanical energy (rotary motion). Its a 3-phase motor in
which the rotor always runs synchronous to the stators rotary field.
This version of the synchronous motor is equipped with an addi-
tional squirrel cage, so that it can be started up in accordance with
the asynchronous motor principle.

Terminals 1 through 3 are used to connect 3-phase current for the


generation of a rotary field in the motors stator. Terminals 5 and 6
are used to connect direct current to the excitation windings. Ter-
minal 4 is a rotary terminal mechanism. A motor test bench or a
further motor can be connected here, for example. (The direction of
rotation is usually reversed via the connection. This can be selected
with the connecting cable.)

If the synchronous motor is idled without a load, a so-called V curve


can be recorded which reflects the relationship between excitation
current and effective stator current. Nominal excitation current
indicates the point of minimum stator current, at which power
factor is also equal to 1.

Nominal excitation current can be specified as a ratio to maximum


excitation current with the parameter Ratio Current : Max. Current.
The absolute value of nominal excitation current is determined by
multiplying maximum excitation current by the specified ratio (e.g.
maximum excitation current 0.95 A * 0.5 = nominal excitation
current 0.475 A).

The synchronous motors characteristic data (for example winding


resistances, inductances, number of pole pairs etc.) are automati-
cally ascertained in the background after entering the performance
data. Details can be found in the following separate section: Simu-
lation of rotating machines.

Adjustable parameters

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 523
Power: 0.001 ... 1000 kW (0.3)
Revolution: 1 ... 10000 1/min (1500)
Power factor cos : 0.1 ... 1 (0.97)
Line-to-line voltage: 1 ... 10000 V (400)
Phase current: 0.1 ... 100 A (0.66)
Frequency: 30 ... 100 Hz (50)
Voltage (Exciter, Max.): 1 ... 10000 V (150)
Current (Exciter, Max.): 0.1 ... 100 A (0.95)
I_f : I_f_max: 0.01 ... 1 (0.5)
External torque: 0 ... 100 N.m (0)

Synchronous motor

The synchronous motor is a machine for converting electrical ener-


gy into mechanical energy (rotary motion). Its a 3-phase motor in
which the rotor always runs synchronous to the stators rotary field.
This version of the synchronous motor is equipped with an addi-
tional squirrel cage, so that it can be started up in accordance with
the asynchronous motor principle.

Terminals 1 through 3 are used to connect 3-phase current for the


generation of a rotary field in the motors stator. Terminals 5 and 6
are used to connect direct current to the excitation windings. Ter-
minal 4 is a rotary terminal mechanism. A motor test bench or a
further motor can be connected here, for example. (The direction of
rotation is usually reversed via the connection. This can be selected
with the connecting cable.) The other electrical terminals are used
for connection to the electrical section of the motor test bench.

If the synchronous motor is idled without a load, a so-called V curve


can be recorded which reflects the relationship between excitation
current and effective stator current. Nominal excitation current
indicates the point of minimum stator current, at which power
factor is also equal to 1.

Nominal excitation current can be specified as a ratio to maximum


excitation current with the parameter Ratio Current : Max. Current.
The absolute value of nominal excitation current is determined by
multiplying maximum excitation current by the specified ratio (e.g.

524 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
maximum excitation current 0.95 A * 0.5 = nominal excitation
current 0.475 A).

The synchronous motors characteristic data (for example winding


resistances, inductances, number of pole pairs etc.) are automati-
cally ascertained in the background after entering the performance
data. Details can be found in the following separate section: Simu-
lation of rotating machines.

Adjustable parameters
Power: 0.001 ... 1000 kW (0.3)
Revolution: 1 ... 10000 1/min (1500)
Power factor cos : 0.1 ... 1 (0.97)
Line-to-line voltage: 1 ... 10000 V (400)
Phase current: 0.1 ... 100 A (0.66)
Frequency: 30 ... 100 Hz (50)
Voltage (Exciter, Max.): 1 ... 10000 V (150)
Current (Exciter, Max.): 0.1 ... 100 A (0.95)
I_f : I_f_max: 0.01 ... 1 (0.5)
External torque: 0 ... 100 N.m (0)

Universal motor

The universal motor is a machine for converting electrical energy


into mechanical energy (rotary motion). Its layout corresponds to
that of a DC series motor (stator and rotor windings are connected
in series). It can be operated with either direct current or alternat-
ing current. As opposed to DC motors, stator and rotor cores are
made of laminated sheet in order to keep eddy-current losses to a
minimum in the case of alternating voltage.

Terminals 1 and 2 are used to connect operating voltage (AC/DC) to


the motor. Terminal 3 is a rotary terminal mechanism. A motor test
bench or a further motor can be connected here, for example. (The
direction of rotation is usually reversed via the connection. This can
be selected with the connecting cable.)

The Current (RMS) parameter is used to specify nominal current for


operation with direct voltage as well as alternating voltage. Idling
speed of the motor during operation with direct current can be

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 525
indicated as a ratio to nominal rotary speed with the parameter Idle
revolution : Rated speed. The absolute value of idling speed is
determined by multiplying nominal speed by the specified ratio
(e.g. nominal rotary speed 2000 rpm * 1.1 = idling speed 2200
rpm). The additional simulation value, Revolution (), is used to
read out average motor speed, so that design-related vibration due
to rotational speed is compensated for in the display in the case of
operation with alternating current.

Adjustable parameters
Characteristic data: Alternating current,Direct current (Alternating
current)
Power: 0.001 ... 1000 kW (0.2)
Revolution: 1 ... 30000 1/min (3000)
Voltage: 1 ... 10000 V (230)
Current: 0.1 ... 100 A (3)
Frequency: 30 ... 100 Hz (50)
U_N_AC : U_N_DC: 1 ... 10 (1.643)
n_0 : n_N: 1.001 ... 100 (1.46)
Direction of rotation: Left,Right (Right)
External torque: 0 ... 100 N.m (0)

Universal motor

The universal motor is a machine for converting electrical energy


into mechanical energy (rotary motion). Its layout corresponds to
that of a DC series motor (stator and rotor windings are connected
in series). It can be operated with either direct current or alternat-
ing current. As opposed to DC motors, stator and rotor cores are
made of laminated sheet in order to keep eddy-current losses to a
minimum in the case of alternating voltage.

In this representation of the universal motor, the terminals for the


armature windings (A1-A2) and the excitation winding (D1-D2) are
led to the outside. In this way, the desired wiring of the windings
can be completed from the outside. The other electrical terminals
are used for connection to the electrical section of the motor test
bench.

526 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Terminal 1 is a rotary terminal mechanism. A motor test bench or a
further motor can be connected here, for example. (The direction of
rotation is usually reversed via the connection. This can be selected
with the connecting cable.)

The Current (RMS) parameter is used to specify nominal current for


operation with direct voltage as well as alternating voltage. Idling
speed of the motor during operation with direct current can be
indicated as a ratio to nominal rotary speed with the parameter Idle
revolution : Rated speed. The absolute value of idling speed is
determined by multiplying nominal speed by the specified ratio
(e.g. nominal rotary speed 2000 rpm * 1.1 = idling speed 2200
rpm). The additional simulation value, Revolution (), is used to
read out average motor speed, so that design-related vibration due
to rotational speed is compensated for in the display in the case of
operation with alternating current.

Adjustable parameters
Characteristic data: Alternating current,Direct current (Alternating
current)
Power: 0.001 ... 1000 kW (0.2)
Revolution: 1 ... 30000 1/min (3000)
Voltage: 1 ... 10000 V (230)
Current: 0.1 ... 100 A (3)
Frequency: 30 ... 100 Hz (50)
U_N_AC : U_N_DC: 1 ... 10 (1.643)
n_0 : n_N: 1.001 ... 100 (1.46)
External torque: 0 ... 100 N.m (0)

DC permanent-magnet motor

The DC permanent-magnet motor is a machine for converting elec-


trical energy into mechanical energy (rotary motion). Its stator
consists of a permanent magnet, and only the armature consists of
a coil through which current flows.

The L+ and L- terminals are used to connect the armature winding.


If L+ is connected to positive potential and L- is connected to
ground, the motor turns in the direction specified in the parame-
ters. Terminal 1 is a rotary terminal mechanism. A motor test bench

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 527
or a further motor can be connected here, for example. (The direc-
tion of rotation is usually reversed via the connection. This can be
selected with the connecting cable.)

Idling speed of the motor can be indicated as a ratio to nominal


rotary speed with the parameter Idle revolution : Rated speed. The
absolute value of idling speed is determined by multiplying nominal
speed by the specified ratio (e.g. nominal rotary speed 2000 rpm *
1.1 = idling speed 2200 rpm).

Winding resistance is calculated automatically based on the en-


tered parameters.

Adjustable parameters
Power: 0.001 ... 1000 kW (0.3)
Revolution: 1 ... 30000 1/min (2000)
Voltage: 1 ... 10000 V (220)
Current: 0.1 ... 100 A (1.8)
Inductance: 1e-6 ... 10 H (0.01)
n_0 : n_N: 1.001 ... 100 (1.1)
Direction of rotation: Left,Right (Right)
External torque: 0 ... 100 N.m (0)

Separately excited DC motor

The separately excited DC motor is a machine for converting electri-


cal energy into mechanical energy (rotary motion). Its armature and
excitation windings are supplied with power from different voltage
sources.

Terminals A1-A2 are used to connect the armature winding and


terminals 1-2 are used to connect the excitation winding. Terminal
3 is a rotary terminal mechanism. A motor test bench or a further
motor can be connected here, for example. (The direction of rota-
tion is usually reversed via the connection. This can be selected
with the connecting cable.) The other electrical terminals are used
for connection to the electrical section of the motor test bench.

Armature and excitation winding connections can be selected in the


motors parameters under Characteristic data. The selection of

528 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
these connections influences automatic calculation of winding
resistances. The desired performance values are only attained if the
motor is externally wired as specified in the parameters.

Idling speed of the motor can be indicated as a ratio to nominal


rotary speed with the parameter Idle revolution : Rated speed. The
absolute value of idling speed is determined by multiplying nominal
speed by the specified ratio (e.g. nominal rotary speed 2000 rpm *
1.1 = idling speed 2200 rpm).

Adjustable parameters
Characteristic data: Shunt-wound machine,Series-wound machine
(Shunt-wound machine)
Power: 0.001 ... 1000 kW (0.3)
Revolution: 1 ... 30000 1/min (2000)
Voltage: 1 ... 10000 V (220)
Current: 0.1 ... 100 A (1.8)
Inductance (Armature): 1e-6 ... 10 H (0.01)
Voltage: 1 ... 10000 V (220)
Current: 0.1 ... 100 A (0.3)
Inductance (Exciter): 1e-6 ... 10 H (0.01)
n_0 : n_N: 1.001 ... 100 (1.1)
External torque: 0 ... 100 N.m (0)

DC series motor

The DC series motor is a machine for converting electrical energy


into mechanical energy (rotary motion). Its armature and excitation
windings are connected in series.

Terminals L+ and L- are used to connected supply power. If L+ is


connected to positive potential and L- is connected to ground, the
motor turns in the direction specified in the parameters. Terminal 1
is a rotary terminal mechanism. A motor test bench or a further
motor can be connected here, for example. (The direction of rota-
tion is usually reversed via the connection. This can be selected
with the connecting cable.)

Idling speed of the motor can be indicated as a ratio to nominal


rotary speed with the parameter Idle revolution : Rated speed. The

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 529
absolute value of idling speed is determined by multiplying nominal
speed by the specified ratio (e.g. nominal rotary speed 2000 rpm *
1.1 = idling speed 2200 rpm).

Winding resistances are calculated automatically based on the


entered parameters.

Adjustable parameters
Power: 0.001 ... 1000 kW (0.3)
Revolution: 1 ... 30000 1/min (2000)
Voltage: 1 ... 10000 V (220)
Current: 0.1 ... 100 A (1.9)
n_0 : n_N: 1.001 ... 100 (1.7)
Direction of rotation: Left,Right (Right)
External torque: 0 ... 100 N.m (0)
Inductance (Armature): 1e-6 ... 10 H (0.001)
Inductance (Exciter): 1e-6 ... 10 H (0.001)

DC shunt motor

The DC shunt motor is a machine for converting electrical energy


into mechanical energy (rotary motion). Its armature and excitation
windings are connected in parallel.

Terminals L+ and L- are used to connected supply power. If L+ is


connected to positive potential and L- is connected to ground, the
motor turns in the direction specified in the parameters. Terminal 1
is a rotary terminal mechanism. A motor test bench or a further
motor can be connected here, for example. (The direction of rota-
tion is usually reversed via the connection. This can be selected
with the connecting cable.)

Idling speed of the motor can be indicated as a ratio to nominal


rotary speed with the parameter Idle revolution : Rated speed. The
absolute value of idling speed is determined by multiplying nominal
speed by the specified ratio (e.g. nominal rotary speed 2000 rpm *
1.1 = idling speed 2200 rpm).

Winding resistances are calculated automatically based on the


entered parameters.

530 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Adjustable parameters
Power: 0.001 ... 1000 kW (0.3)
Revolution: 1 ... 30000 1/min (2000)
Voltage: 1 ... 10000 V (220)
Current: 0.1 ... 100 A (1.8)
Inductance (Armature): 1e-6 ... 10 H (0.001)
Voltage: 1 ... 10000 V (220)
Current: 0.1 ... 100 A (0.3)
Inductance (Exciter): 1e-6 ... 10 H (0.001)
n_0 : n_N: 1.001 ... 100 (1.1)
Direction of rotation: Left,Right (Right)
External torque: 0 ... 100 N.m (0)

Motor test bench

The motor test bench is used to test a connected motor independ-


ent of its normal conditions of use. Examinations can be conducted
with reference to a given torque or a given rotational speed.

A rotary terminal mechanism, for example at a motor, can be con-


nected to the motor test bench via terminal 1. A specific, predefined
load or a specified rotational speed can then be selected at the
motor test bench. The selected load or limited rotational speed acts
upon the connected shaft as soon as the switch next to the rotary
terminal is activated. Not until then is a mechanical connection
established, as a result of which the connected motor is subjected
to a load.

The way in which the selected torque acts upon the connected
motor can be specified in the parameters of the motor test bench
under Controlled variable. Torque (braking) means that the select-
ed torque value acts upon the motor as friction or as reaction
torque in opposition to the motors torque. Torque (driving) means
that the motor test bench functions itself as a drive and applies the
corresponding torque to the connected axis of rotation. If a rota-
tional speed is specified, torque output or input is adjusted such
that the desired rotational speed is attained. With regard to the
regulation of rotational speed, maximum torque can be specified as
a separate parameter.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 531
This component represents the mechanical section of the motor
test bench from Festo Didactics equipment set TP 1410, Servo
brake and drive system.

Adjustable parameters
Controlled variable: Torque (braking),Torque (driving),Revolution
(Torque (braking))
Torque: -100 ... 100 N.m (0)
Revolution: 0 ... 30000 1/min (0)
Torque (max): 0.1 ... 100 N.m (10)
Moment of inertia: 1e-6 ... 10 kg.m2 (0.0001)

Connector panel (motor test bench, electrical section)

This element is used to measure certain characteristic data, for


example effective power and apparent power, of a motor during
simulation.

The Motor and terminals are used to connect the motors thermal
switch. Connect these two terminals to the motors M and termi-
nals. Input terminals L1, L2 and L3 at the top are used to connect
supply power. The motor is connected to output terminals L1, L2
and L3 at the bottom. The PE terminal is for the protective conduc-
tor.

This component represents the electrical section of the motor test


bench from Festo Didactics equipment set TP 1410, Servo brake
and drive system.

Adjustable parameters
Time interval: 0.001 ... 100 s (0.1)

532 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
21.5.7 Controller

Summator

The summator element is a closed-loop control technology compo-


nent. An output signal/potential is generated at output 4, which
corresponds to the sum of the three input signals/potentials at
inputs 1 through 3. In order to keep circuit wiring as straightfor-
ward as possible, required earthing (0 V) is not led out as a termi-
nal, but rather wired internally.

The output signals voltage range is determined by the potential


applied to terminals A1 and A2 relative to ground (0 V). If a positive
potential is connected to A1 and a negative potential to A2, the
available output signal is no greater than the smaller numeric value
of the two (example: A1 = +15 V, A2 = -10 V => control range = 10
V). This can be further limited by means of a parameter, in order to
take losses from the control electronics within the component into
account.

The component does not generate an output signal unless a mini-


mum potential is connected to both the A1 and the A2 terminals.
The value can be adjusted in the advanced settings. If either termi-
nal A1 or A2 is not connected to any potential, the potential of the
connected terminal is passed through to the output (4).

This element is based on the element with the same designation


from Festo Didactics equipment set for Basic principles of control
technology (TP 1013).

Adjustable parameters
y offset: -5 ... 5 V (0)
Efficiency: 0 ... 1 (0.9)
Minimum voltage: 0 ... 10 V (1.5)

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 533
D element

The D element is a transfer element used in closed-loop control


technology with a derivative response characteristic. The output
signal/potential at output 2 depends on the rate of change of the
input signal/potential at input 1. The D element is modelled as an
actual D element in this case, also known as a derivative-action
element, with first-order time delay, because an ideal D element is
technically infeasible. Derivative-action coefficient Kd and delay
time T can be adjusted. In order to keep circuit wiring as straight-
forward as possible, required earthing (0 V) is not led out as a
terminal, but rather wired internally.

The output signals voltage range is determined by the potential


applied to terminals A1 and A2 relative to ground (0 V). If a positive
potential is connected to A1 and a negative potential to A2, the
available output signal is no greater than the smaller numeric value
of the two (example: A1 = +15 V, A2 = -10 V => control range = 10
V). This can be further limited by means of a parameter, in order to
take losses from the control electronics within the component into
account.

The component does not generate an output signal unless a mini-


mum potential is connected to both the A1 and the A2 terminals.
The value can be adjusted in the advanced settings. If either termi-
nal A1 or A2 is not connected to any potential, the potential of the
connected terminal is passed through to the output (4).

This element is based on the element with the same designation


from Festo Didactics equipment set for Basic principles of control
technology (TP 1013).

Adjustable parameters
Derivation gain: 1 ... 1000 ms (2)
Time constant (PT1): 0.01 ... 100 ms (1)
Efficiency: 0 ... 1 (0.9)
Minimum voltage: 0 ... 10 V (1.5)

534 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
P element

The P element is a transfer element used in closed-loop control


technology with a proportional response characteristic. The input
signal/potential at input 1 is amplified by adjustable proportional-
action coefficient Kp and read out as an output signal/potential at
output 2. In the event of a proportional-action coefficient of less
than 1, we no longer speak of amplification, but rather of attenua-
tion. In order to keep circuit wiring as straightforward as possible,
required earthing (0 V) is not led out as a terminal, but rather wired
internally.

The output signals voltage range is determined by the potential


applied to terminals A1 and A2 relative to ground (0 V). If a positive
potential is connected to A1 and a negative potential to A2, the
available output signal is no greater than the smaller numeric value
of the two (example: A1 = +15 V, A2 = -10 V => control range = 10
V). This can be further limited by means of a parameter, in order to
take losses from the control electronics within the component into
account.

The component does not generate an output signal unless a mini-


mum potential is connected to both the A1 and the A2 terminals.
The value can be adjusted in the advanced settings. If either termi-
nal A1 or A2 is not connected to any potential, the potential of the
connected terminal is passed through to the output (4).

This element is based on the element with the same designation


from Festo Didactics equipment set for Basic principles of control
technology (TP 1013).

Adjustable parameters
Proportional gain: 0 ... 1000 (1)
Efficiency: 0 ... 1 (0.9)
Minimum voltage: 0 ... 10 V (1.5)

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 535
Hysteresis element

The hysteresis element acts as a two-step action controller with


symmetrical hysteresis. If the input signal/potential at input 1 is
increased to above the selected hysteresis value, output 2 auf is
switched to +15 V. If the input signal/potential then drops to below
the hysteresis value with a preceding minus sign, the output is
switched to -15 V. In order to keep circuit wiring as straightforward
as possible, required earthing (0 V) is not led out as a terminal, but
rather wired internally.

The output signals voltage range is determined by the potential


applied to terminals A1 and A2 relative to ground (0 V). If a positive
potential is connected to A1 and a negative potential to A2, the
available output signal is no greater than the smaller numeric value
of the two (example: A1 = +15 V, A2 = -10 V => control range = 10
V). This can be further limited by means of a parameter, in order to
take losses from the control electronics within the component into
account.

The component does not generate an output signal unless a mini-


mum potential is connected to both the A1 and the A2 terminals.
The value can be adjusted in the advanced settings. If either termi-
nal A1 or A2 is not connected to any potential, the potential of the
connected terminal is passed through to the output (4).

This element is based on the element with the same designation


from Festo Didactics equipment set for Basic principles of control
technology (TP 1013).

Adjustable parameters
Hysteresis: 0 ... 10 V (0)
Efficiency: 0 ... 1 (0.9)
Minimum voltage: 0 ... 10 V (1.5)

536 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
I element

The I element is a transfer element used in closed-loop control


technology with an integral response characteristic. The input
signal/potential at input 1 is summed up over time and results in
the output signal/potential at output 2. The speed at which the
input signal is integrated can be adjusted with the integral-action
coefficient. In order to keep circuit wiring as straightforward as
possible, required earthing (0 V) is not led out as a terminal, but
rather wired internally.

The output signals voltage range is determined by the potential


applied to terminals A1 and A2 relative to ground (0 V). If a positive
potential is connected to A1 and a negative potential to A2, the
available output signal is no greater than the smaller numeric value
of the two (example: A1 = +15 V, A2 = -10 V => control range = 10
V). This can be further limited by means of a parameter, in order to
take losses from the control electronics within the component into
account.

The component does not generate an output signal unless a mini-


mum potential is connected to both the A1 and the A2 terminals.
The value can be adjusted in the advanced settings. If either termi-
nal A1 or A2 is not connected to any potential, the potential of the
connected terminal is passed through to the output (4).

This element is based on the element with the same designation


from Festo Didactics equipment set for Basic principles of control
technology (TP 1013).

Adjustable parameters
Integral gain: 1 ... 1000 1/s (100)
Efficiency: 0 ... 1 (0.9)
Minimum voltage: 0 ... 10 V (1.5)

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 537
PT1 element

The PT1 element is a first-order proportional delay element used in


closed-loop control technology. The input signal/potential at input
1 is amplified or attenuated by proportional-action coefficient Kp
and delayed by delay time T, and is read out as the output sig-
nal/potential at output 2. In order to keep circuit wiring as straight-
forward as possible, required earthing (0 V) is not led out as a
terminal, but rather wired internally.

The output signals voltage range is determined by the potential


applied to terminals A1 and A2 relative to ground (0 V). If a positive
potential is connected to A1 and a negative potential to A2, the
available output signal is no greater than the smaller numeric value
of the two (example: A1 = +15 V, A2 = -10 V => control range = 10
V). This can be further limited by means of a parameter, in order to
take losses from the control electronics within the component into
account.

The component does not generate an output signal unless a mini-


mum potential is connected to both the A1 and the A2 terminals.
The value can be adjusted in the advanced settings. If either termi-
nal A1 or A2 is not connected to any potential, the potential of the
connected terminal is passed through to the output (4).

This element is based on the element with the same designation


from Festo Didactics equipment set for Basic principles of control
technology (TP 1013).

Adjustable parameters
Time: 0.001 ... 1 s (0.01)
Proportional gain: 0 ... 10 (1)
Efficiency: 0 ... 1 (0.9)
Minimum voltage: 0 ... 10 V (1.5)

538 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
PT2 element

The PT2 element is a second-order proportional delay element used


in closed-loop control technology. The input signal/potential at
input 1 is amplified or attenuated by proportional-action coefficient
Kp and delayed by delay times T1 and T2, and is read out as the
output signal/potential at output 2. In order to keep circuit wiring
as straightforward as possible, required earthing (0 V) is not led out
as a terminal, but rather wired internally.

The output signals voltage range is determined by the potential


applied to terminals A1 and A2 relative to ground (0 V). If a positive
potential is connected to A1 and a negative potential to A2, the
available output signal is no greater than the smaller numeric value
of the two (example: A1 = +15 V, A2 = -10 V => control range = 10
V). This can be further limited by means of a parameter, in order to
take losses from the control electronics within the component into
account.

The component does not generate an output signal unless a mini-


mum potential is connected to both the A1 and the A2 terminals.
The value can be adjusted in the advanced settings. If either termi-
nal A1 or A2 is not connected to any potential, the potential of the
connected terminal is passed through to the output (4).

This element is based on the element with the same designation


from Festo Didactics equipment set for Basic principles of control
technology (TP 1013).

Adjustable parameters
Time constant: 0.001 ... 1 s (0.01)
Proportional gain: 0 ... 10 (1)
Damping: 1e-5 ... 1000 s (1)
Efficiency: 0 ... 1 (0.9)
Minimum voltage: 0 ... 10 V (1.5)

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 539
Differential amplifier

The differential amplifier is a closed-loop control technology com-


ponent. An output signal/potential is generated at output 3, which
corresponds to the difference between the two input sig-
nals/potentials at inputs 1 (w) and 2 (x). In the field of closed-loop
control technology, the differential amplifier is used to determine
deviation. In order to keep circuit wiring as straightforward as
possible, required earthing (0 V) is not led out as a terminal, but
rather wired internally.

The output signals voltage range is determined by the potential


applied to terminals A1 and A2 relative to ground (0 V). If a positive
potential is connected to A1 and a negative potential to A2, the
available output signal is no greater than the smaller numeric value
of the two (example: A1 = +15 V, A2 = -10 V => control range = 10
V). This can be further limited by means of a parameter, in order to
take losses from the control electronics within the component into
account.

The component does not generate an output signal unless a mini-


mum potential is connected to both the A1 and the A2 terminals.
The value can be adjusted in the advanced settings. If either termi-
nal A1 or A2 is not connected to any potential, the potential of the
connected terminal is passed through to the output (4).

This element is based on the element with the same designation


from Festo Didactics equipment set for Basic principles of control
technology (TP 1013).

Adjustable parameters
Efficiency: 0 ... 1 (0.9)
Minimum voltage: 0 ... 10 V (1.5)

Limiter

The limiter is a closed-loop control technology component. Within a


defined voltage range, the input signal/potential at input 1 is

540 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
replicated to another defined voltage range of the output sig-
nal/potential. In order to keep circuit wiring as straightforward as
possible, required earthing (0 V) is not led out as a terminal, but
rather wired internally.

The voltage range of the input and output signals is specified after
selecting the Operating mode option. The output signal is addition-
ally limited by the potentials applied to terminals A1 and A2 relative
to ground (0 V). If a positive potential is connected to A1 and a
negative potential to A2, the available output signal is no greater
than the smaller numeric value of the two (example: A1 = +15 V, A2
= -10 V => control range = 10 V). This can be further limited by
means of a parameter, in order to take losses from the control
electronics within the component into account.

The component does not generate an output signal unless a mini-


mum potential is connected to both the A1 and the A2 terminals.
The value can be adjusted in the advanced settings. If either termi-
nal A1 or A2 is not connected to any potential, the potential of the
connected terminal is passed through to the output (4).

This element is based on the element with the same designation


from Festo Didactics equipment set for Basic principles of control
technology (TP 1013).

Adjustable parameters
Operating mode: In [-10 V..10 V] > Out [0 V..10 V], In [-10 V..10 V]
> Out [-10 V..10 V],Enter manually (In [-10 V..10 V] > Out [0 V..10
V])
Efficiency: 0 ... 1 (0.9)
Min. Voltage (in): -400 ... 400 V (-10)
Max. Voltage (in): -400 ... 400 V (10)
Min. Voltage (out): -400 ... 400 V (-10)
Max. Voltage (out): -400 ... 400 V (10)
Minimum voltage: 0 ... 10 V (1.5)

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 541
21.5.8 Controller (block diagram)

Summator

The summator element is a closed-loop control technology compo-


nent. An output signal/potential is generated at output 4, which
corresponds to the sum of the three input signals/potentials at
inputs 1 through 3. In order to keep circuit wiring as straightfor-
ward as possible, required earthing (0 V) and supply voltage are
not led out as a terminals, but rather wired internally.

Adjustable parameters
y offset: -5 ... 5 V (0)

D element

The D element is a transfer element used in closed-loop control


technology with a derivative response characteristic. The output
signal/potential at output 2 depends on the rate of change of the
input signal/potential at input 1. The D element is modelled as an
actual D element in this case, also known as a derivative-action
element, with first-order time delay, because an ideal D element is
technically infeasible. Derivative-action coefficient Kd and delay
time T can be adjusted. In order to keep circuit wiring as straight-
forward as possible, required earthing (0 V) and supply voltage are
not led out as a terminals, but rather wired internally.

Adjustable parameters
Derivation gain: 1 ... 1000 ms (2)
Time constant (PT1): 0.01 ... 100 ms (0.8)

542 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
P element

The P element is a transfer element used in closed-loop control


technology with a proportional response characteristic. The input
signal/potential at input 1 is amplified by adjustable proportional-
action coefficient Kp and read out as an output signal/potential at
output 2. In the event of a proportional-action coefficient of less
than 1, we no longer speak of amplification, but rather of attenua-
tion. In order to keep circuit wiring as straightforward as possible,
required earthing (0 V) and supply voltage are not led out as a
terminals, but rather wired internally.

Adjustable parameters
Proportional gain: 0 ... 1000 (1)

Hysteresis element

The hysteresis element acts as a two-step action controller with


symmetrical hysteresis. If the input signal/potential at input 1 is
increased to above the selected hysteresis value, output 2 auf is
switched to +15 V. If the input signal/potential then drops to below
the hysteresis value with a preceding minus sign, the output is
switched to -15 V. In order to keep circuit wiring as straightforward
as possible, required earthing (0 V) and supply voltage are not led
out as a terminals, but rather wired internally.

Adjustable parameters
Hysteresis: 0 ... 10 V (0)
Minimum output voltage: -400 ... 400 V (-1)
Maximum output voltage: -400 ... 400 V (1)

I element

The I element is a transfer element used in closed-loop control


technology with an integral response characteristic. The input

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 543
signal/potential at input 1 is summed up over time and results in
the output signal/potential at output 2. The speed at which the
input signal is integrated can be adjusted with the integral-action
coefficient. In order to keep circuit wiring as straightforward as
possible, required earthing (0 V) and supply voltage are not led out
as a terminals, but rather wired internally.

Adjustable parameters
Integral gain: 1 ... 1000 1/s (100)

PT1 element

The PT1 element is a first-order proportional delay element used in


closed-loop control technology. The input signal/potential at input
1 is amplified or attenuated by proportional-action coefficient Kp
and delayed by delay time T, and is read out as the output sig-
nal/potential at output 2. In order to keep circuit wiring as straight-
forward as possible, required earthing (0 V) and supply voltage are
not led out as a terminals, but rather wired internally.

Adjustable parameters
Time: 0.001 ... 1 s (0.01)
Proportional gain: 0 ... 10 (1)

PT2 element

The PT2 element is a second-order proportional delay element used


in closed-loop control technology. The input signal/potential at
input 1 is amplified or attenuated by proportional-action coefficient
Kp and delayed by delay times T1 and T2, and is read out as the
output signal/potential at output 2. In order to keep circuit wiring
as straightforward as possible, required earthing (0 V) and supply
voltage are not led out as a terminals, but rather wired internally.

Adjustable parameters
Time constant: 1e-5 ... 1 s (0.01)
Proportional gain: 0 ... 10 (1)

544 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Damping: 1e-5 ... 1000 s (1)

Differential amplifier

The differential amplifier is a closed-loop control technology com-


ponent. An output signal/potential is generated at output 3, which
corresponds to the difference between the two input sig-
nals/potentials at inputs 1 (w) and 2 (x). In the field of closed-loop
control technology, the differential amplifier is used to determine
deviation. In order to keep circuit wiring as straightforward as
possible, required earthing (0 V) and supply voltage are not led out
as a terminals, but rather wired internally.

Limiter

The limiter is a closed-loop control technology component. Within a


defined voltage range, the input signal/potential at input 1 is
replicated to another defined voltage range of the output sig-
nal/potential. In order to keep circuit wiring as straightforward as
possible, required earthing (0 V) and supply voltage are not led out
as a terminals, but rather wired internally.

The voltage range of the input and output signals is specified after
selecting the Operating mode option.

Adjustable parameters
Operating mode: In [-10 V..10 V] > Out [0 V..10 V], In [-10 V..10 V]
> Out [-10 V..10 V],Enter manually (In [-10 V..10 V] > Out [0 V..10
V])
Min. Voltage (in): -400 ... 400 V (-10)
Max. Voltage (in): -400 ... 400 V (10)
Min. Voltage (out): -400 ... 400 V (-10)
Max. Voltage (out): -400 ... 400 V (10)

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 545
21.6 Digital Components

21.6.1 Constants and Terminals

Digital input

Digital inputs are designated with an I. In FluidSIM digital com-


ponents can be used inside and outside a digital module. If a
digital input is used inside a digital module, you can determine the
input connector of the digital module in question with which the
digital input shall be linked by allocating a number I1 to I16. If
there is an analog signal of more than 10V at the chosen input of
the digital module, the digital input is set to Hi. If a digital input is
used outside a digital module, there is an additional analog electri-
cal connection at the digital input. If there is an analog signal of
more than 10V at this connection, the digital input is set to Hi. As
an alternative you can click on the digital input with the left mouse
button in order to set it to Hi. Another click resets the value to
Lo.

Digital output

Digital outputs are designated with an Q. The output connects a


digital signal through from its input to its output. In FluidSIM digital
components can be used inside and outside a digital module. If a
digital output is used inside a digital module, you can determine
the output connector of the digital module in question with which
the digital output shall be linked by allocating a number Q1 to
Q16. If the status of the digital output is Hi, a potential of 24V
is set at the corresponding output connector of the digital module.
If a digital output is used outside a digital module, there is an
additional analog electrical connection at the digital output. If the
status of the digital output is Hi, a potential of 24 V is set at this
connection.

546 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Memory bits

Memory bits are designated with a M. Memory bits are virtual


outputs, with a value at their output analog to that at their input.
When the simulation start is activated, you can define by using the
property dialog box if the output Q shall be set to Lo or to Hi,
independent on the input value. After the simulation start the value
at the output is set to the value of the input.

Adjustable parameters
Initial state = Hi: ... (false)

Logic level HI

At the output Q you have the logic level Hi.

Logic level LO

At the output Q you have the logic level Lo.

Connection (digital)

An digital connection is a place where a digital line can be attached


to. To simplify the line drawing process, a connection appears as a
small circle in Edit Mode. Note that at each digital connection its
level Lo / Hi can be displayed.

Line (digital)

A digital line links two digital connections. Note that a digital con-
nection may be a simple digital connection or a T-junction.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 547
T-junction (digital)

A T-junction joins up to four digital lines, thus having a single


digital level. Note that T-junctions are introduced automatically by
FluidSIM when dropping the line drawing cursor onto another line
in Edit Mode.

21.6.2 Basic Functions

AND

The output Q of the AND is only Hi when all inputs are Hi, that
is, if they are closed. If an input pin of this module is not connected,
its status is automatically Hi.

Edge-triggered AND

The output Q of the edge-triggered AND is only Hi when all inputs


are Hi and if at least one input was Lo in the previous cycle. If
an input pin of this block is not connected, its status is automatical-
ly Hi.

NAND (AND not)

The output Q of the NAND is only Lo, when all inputs are Hi,
that is, if they are closed. If an input pin of this block is not con-
nected, its status is automatically Hi.

548 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
NAND With Edge Evaluation

The output Q of the NAND with edge evaluation is only Hi, if at


least one input is Lo and if all inputs were Hi in the previous
cycle. If an input pin of this block is not connected, its status is
automatically Hi.

OR

The output Q of the OR is only Hi, if at least one input is Hi, that
is, if it is closed. If an input pin of this block is not connected, its
status is automatically Lo.

NOR (OR not)

The output Q of the NOR is only Hi when all inputs are Lo, that
is, if they are switched off. As soon as any input is switched on
(status Hi), the output of the NOR is set to Lo. If an input pin of
this block is not connected, its status is automatically Lo.

XOR (exclusive OR)

The output Q of the XOR is Hi, if the inputs are nonequivalent. If


an input pin of this block is not connected, its status is automatical-
ly Lo.

NOT (Negation, Inverter)

The output Q is Hi if the input is Lo. The NOT block is an input


status inverter.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 549
21.6.3 Special Functions

Digital module

The digital module is used for a compact embedding of a digital


switching circuit into a electropneumatic or electrohydraulic circuit.
The digital module offers 8 (16) electrical inputs and outputs, which
transfer their states to its digital switching circuit in the inner part.
Therefore the digital switching circuit does not need much space in
the electropneumatic or electrohydraulic circuit for the display of
the digital module as a rectangle with a total number of 18 (34)
connections. By making a double-click with the left mouse button
on the digital module you come to the digital circuit in the inner
part of the module. A new window opens. It shows the digital circuit
and can be handled in the usual way. The standard configuration in
the inner part of a new inserted digital module is a row with 8 (16)
inputs and 8 (16) outputs each. They correspond to the inputs and
outputs of the module in the electropneumatic or electrohydraulic
circuit. In order to be able to test the digital circuit during the setup,
it can be simulated separated from the electropneumatic or elec-
trohydraulic circuit. As soon as the processing window of the digital
module is closed or the original circuit window is put into the fore-
ground, the previously effected changes in the digital circuit are
automatically adopted into the digital module of the
electropneumatic or electrohydraulic circuit. Inside the digital
module only digital components can be inserted. Furthermore, an
encapsulating of additional digital modules inside a module is not
possible. However, you can use several digital modules in one
electropneumatic or electrohydraulic circuit. Please note that the
digital circuit inside a digital module only works correctly if corre-
sponding potentials are set at the electrical power supply units of
the module (+24 V) and (0 V).

On delay

An output with on delay is not switched on until a specified time


has expired. When the status of input Trg changes from Lo to

550 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Hi, the on delay time starts. If the status of input Trg is Hi at
least for the duration of the configured time, the output Q is set to
Hi on expiration of this time. The output follows the input with on
delay. The time is reset, when the status of the input changes again
to Lo before the time has expired. The output is reset to Lo,
when the status at the input is Lo.

Adjustable parameters
Delay time: 0 ... 100 s (3)

Off delay

The output is not reset until a configured time has expired. When
the input status turns to Hi, the output Q is switched instantane-
ously to Hi. If the status at input Trg changes from Hi to Lo,
the off delay starts. After expiration of the configured time, the
output is reset to Lo (off delay). When the input Trg is switched
on and off again, the off delay restarts. The input R (Reset) is used
to reset the delay time and the output before the configured time
has expired.

Adjustable parameters
Delay time: 0 ... 100 s (3)

On/Off delay

An output with on/off delay is switched on after a specified time


and is reset on expiration of a second specified time. As soon as the
status at input Trg changes from Lo to Hi, the configured on
delay time starts. If the status at input Trg remains Hi at least for
the duration of the configured time, the output Q is set to Hi on
expiration of the on delay time (the output follows the input on
delayed). If the status at input Trg changes again to Lo, before
the configured on delay time has expired, the time is reset. When
the status at input returns to Lo, the configured off delay time
starts. If the status at the input remains Lo at least for the dura-
tion of the configured off delay time, the output is set to Lo on

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 551
expiration of that time (the output follows the input off delayed). If
the status at the input returns to Hi before this time has expired,
the time is reset.

Adjustable parameters
On delay time: 0 ... 100 s (3)
Off delay time: 0 ... 100 s (6)

Retentive On delay

A specified time starts after an input pulse. The output is set on


expiration of this time. As soon as the status at the input Trg
changes from Lo to Hi, the specified time starts. After expira-
tion on the configured time, the output Q is set to Hi. Further
switching actions at input Trg have no influence on the running
time. The output and the time are only reset to Lo when the
status at input R is Hi.

Adjustable parameters
Delay time: 0 ... 100 s (3)

Latching Relay

Input S sets output Q. Another input R resets the output Q. A latch-


ing relay is a simple logic memory. The output value depends on
the input states and on the previous output status.

Pulse Relay

A short oneshot at the input is used to set and reset the output.
Output Q status is toggled at every Lo to Hi transition of the
status at input Trg, that is, the output is switched on or off. Use
input R to reset the pulse relay to initial state, that is, the output is
set to Lo.

552 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Wiping Relay - Pulse Output

An input signal generates a signal of specified length at the output.


The output status is switched to Hi after the input Trg is set to
Hi. The configured time is started at the same time and the out-
put remains set. After expiration of the configured time, the output
is reset to the status Lo (pulse output). If the input status chang-
es from Hi to Lo before the specified time has expired, also the
output follows immediately with a with a Hi to Lo transition.

Adjustable parameters
Delay time: 0 ... 100 s (3)

Edgetriggered Wiping Relay

An input signal generates a signal of specified length at the output


(retriggering). The output status is switched to Hi after the input
Trg is set to Hi. The configured time is started at the same time.
After expiration of the configured time, the output Q status is reset
to Lo (pulse output). If the input status changes again from Lo
to Hi (retriggering), before the specified time has expired, the
time is reset and the output remains switched on.

Adjustable parameters
Delay time: 0 ... 100 s (3)

Timer Switch

With the timer switch you can create timer switches referring to
days, weeks and years. Upon reach of the specified on-transition
time, the output Q of the timer switch is set to Hi and upon reach
of the specified off-transition time to Lo. If you have chosen the
option Repeat every, the on and off transition is repeated each
time according to the specified repetition time.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 553
Adjustable parameters
On time: 0 ... 1000 s (10)
Off time: 0.1 ... 1000 s (30)
Repeat every: 0.1 ... 1000 s (60)

Up/Down Counter

Depending on the configuration of the input Dir, an internal value is


counted up or down through an input pulse. The output is set when
the configured count value is reached. With every status change at
the input Cnt from Lo to Hi, the internal counter is increased
(Dir = Lo) or decreased (Dir = Hi) by one unit. If the internal
counter is equal or larger compared to the specified value, the
output Q is set to Hi. You can use the reset input R to reset the
internal count value and the output to Lo. As long as R=Hi, also
the output is Lo and the pulses at input Cnt are not counted.

Adjustable parameters
Counter: 0 ... 9999 (5)

Symmetric Clock Generator

A timing signal with a configurable period is given at the output. Via


the duration of the pulses you can determine the length of the on
and off times. Via the input En (for Enable) you can switch on the
clock generator, that is, the clock generator sets the output to Hi
for the duration of the pulse, subsequent the output to Lo for the
duration of the pulse and so on, until the input status is Lo again.

Adjustable parameters
Impulse time: 0.0005 ... 100 s (0.5)

554 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Asynchronous Pulse Generator

The pulse profile of the output can be changed via the configurable
pulse duration and pulse pause duration. It is possible to invert the
output with input INV. The input INV only negates the output, if the
block is enabled via EN.

Adjustable parameters
Impulse time: 0.01 ... 100 s (3)
Impulse pause time: 0.01 ... 100 s (1)

Frequency Threshold Trigger

The output is switched on and off depending on two frequencies


which can be specified. The threshold trigger measures the signals
at input Fre. The pulses are captured across a measuring interval
which can be specified. If the frequency measured within the meas-
uring interval higher than the input frequency, the output Q is
switched to Hi. Q is switched again to Lo when the measured
frequency has reached the value of the output frequency or if it is
lower.

Adjustable parameters
On frequency: 0.01 ... 9999 Hz (6)
Off frequency: 0.01 ... 9999 Hz (2)
Time interval: 0.001 ... 100 s (5)

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 555
21.7 GRAFCET Elements

21.7.1 GRAFCET

Step

The name of a step may contain the following characters: 0-9, a-


z, A-Z and the underscore _. You can select from the following
seven different step types: simple step, initial step, macro-step,
macro input, macro output, enclosing step and initial enclosing
step. Furthermore, you can give the step an activation link.

Transition

You can give a transition a name, which is shown to the left of the
transition in brackets. Entering a transition condition is supported
by buttons for special symbols (AND, OR, NOT, falling edge, rising
edge, delay). Via Variable you can select an existing GRAFCET
variable from a list. Alternatively to the formula, you can show a
descriptive text. To do this, you have to select the option Display
description instead of formula. In the Connection ID/target in-
formation field, you can enter a step that links to the transitions
output without having to draw a connecting line. You can select an
existing step from a list.

Action

There are three types of action: assignations, allocations and


compulsory commands. For assignations and allocations, you can
enter a variable or an output, whose value is changed by the action.
The name of a variable may contain the following characters: 0-9,
a-z, A-Z and the underscore _. For a conditional action or

556 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
an Action on event, you can enter a condition that has to be
fulfilled before the action is executed. Entering a condition is sup-
ported by buttons for special symbols (AND, OR, NOT, falling edge,
rising edge, delay). Via Variable you can select an existing
GRAFCET variable from a list. Alternatively to the formula, you can
show a descriptive text. To do this, you have to select the option
Display description instead of formula. For an allocation (action
on activation, action on deactivation and action on event), you
can enter any term whose value is to be allocated to the action
variable. Entering a term is supported by buttons for special sym-
bols (AND, OR, NOT, falling edge, rising edge). Via Variable you
can select an existing GRAFCET variable from a list. Alternatively to
the formula, you can show a descriptive text. To do this, you have
to select the option Display description instead of formula. For a
compulsory command, you can enter the name of the partial
GRAFCET directly or select an existing partial GRAFCET from a list.
You can also enter the relevant steps directly or select them from a
list of existing steps. You have to separate the step names with
commas. You can select the special commands * and INIT using
the relevant buttons.

Synchronization

You can connect synchronizations like other FluidSIM components.


However, they do not initially have any connections. You always
have to draw connecting lines to a synchronization. The corre-
sponding connections are then generated automatically.

Partial GRAFCET

If you want to allocate GRAFCET elements to a specific partial


GRAFCET, place the partial GRAFCET frame over the relevant
GRAFCET part and give it a name. The preceding G is not part of
the name that you have to enter; it is added automatically by
FluidSIM and shown at the bottom left of the partial GRAFCET
frame. You can alter the size of the partial GRAFCET frame by drag-
ging its edges with the mouse. For the partial GRAFCET to function
correctly, it is important that all its elements are completely within

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 557
the frame and that the frame does not overlap with any foreign
elements or other frames.

GRAFCET-PLC-Component

The GRAFCET-PLC component is similar to a SPS controller, whose


behavior is described by a GRAFCET. For more information, please
read the section GRAFCET-PLC-Component.

GRAFCET-PLC-Component

The GRAFCET-PLC component is similar to a SPS controller, whose


behavior is described by a GRAFCET. For more information, please
read the section GRAFCET-PLC-Component.

GRAFCET-PLC-Component

The GRAFCET-PLC component is similar to a SPS controller, whose


behavior is described by a GRAFCET. For more information, please
read the section GRAFCET-PLC-Component.

GRAFCET-I/O

The GRAFCET I/O component is used to link the GRAFCET variables


with the electrical part of a circuit. You can enter eight GRAFCET
input variables and eight GRAFCET output variables into the
GRAFCET I/O component. The actions' variables serve as outputs.
The inputs can be the allocations and conditions of actions and
transitions. If a potential is created as the input of the GRAFCET I/O
component, the corresponding variable is set to 1. If an output
variable has a value other than 0, a potential of 24V is created at
the corresponding output of the GRAFCET I/O component.

558 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
21.8 Miscellaneous

21.8.1 Miscellaneous

Connection (mechanical)

A mechanical connection constitutes a place holder for the label of


a valve solenoid. To simplify clicking, a mechanical connection
appears as a small circle in Edit Mode.

Valve solenoid

The valve solenoid switches the valve. By means of a label the valve
solenoid can be linked to a valve that is solenoid operated.

Adjustable parameters
Resistance: 1 ... 10000 Ohm (90)
Minimum voltage: 0.1 ... 300 V (20)

Proportional valve solenoid, position controlled

In FluidSIM the proportional valve solenoid is coupled to the re-


spective continuous directional valve with the help of a label. The
required slide position is predetermined via a voltage signal. The
valve slide distance is position controlled. The control and amplifier
component is integrated in the valve.

Adjustable parameters
Current (max): 0.01 ... 10 A (0.1)
Resistance: 1 ... 10000 Ohm (128)

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 559
Minimum voltage: 0.1 ... 300 V (20)

Proportional amplifier, 1-channel

The amplifier is used to control proportional valves. For this pur-


pose, nominal values (voltage signals) from 0 V to +10 V are trans-
formed into the necessary magnetic current for the proportional
valves. In FluidSIM the amplifier is coupled to the respective valve
with the help of a label. The maximum current at the amplifier
output is hereby automatically adjusted in relation to the coupled
valve. A step current relative to the maximum current can be speci-
fied, in order to compensate the positive overlap of proportional
valves. The amplifier requires a power supply of 24 V.

Adjustable parameters
Current (max): 0.01 ... 30 A (0.1)
Jump current: 0 ... 25 % (0)
Resistance: 1 ... 10000 Ohm (100)
Minimum voltage: 0.1 ... 300 V (20)

Proportional amplifier, 2-channel

The amplifier is used to control proportional valves with two mag-


nets. For this purpose, nominal values (voltage signals) from -10 V
to +10 V are transformed into the necessary magnetic current for
the proportional valves. Output A is gated at a nominal value be-
tween 0 V and -10 V, output B between 0 V and -10 V. In FluidSIM
the amplifier is coupled to the respective valve with the help of two
labels. The maximum currents at the amplifier outputs are hereby
automatically adjusted in relation to the coupled valves. A step
current relative to the maximum current can be specified, in order
to compensate the positive overlap of proportional valves. The
amplifier requires a power supply of 24 V.

Adjustable parameters
Current (max): 0.01 ... 30 A (0.1)
Jump current: 0 ... 25 % (0)

560 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Resistance: 1 ... 10000 Ohm (100)
Minimum voltage: 0.1 ... 300 V (20)

Valve solenoid (ladder)

The valve solenoid switches the valve. By means of a label the valve
solenoid can be linked to a valve that is solenoid operated.

Adjustable parameters
Resistance: 1 ... 10000 Ohm (90)
Minimum voltage: 0.1 ... 300 V (20)

Distance rule

The distance rule is a device for attaching switches at the cylinder.


The labels at the distance rule define links to the actual proximity
switches or limit switches in the electrical circuit.

Status indicator

In Edit Mode, the status indicator is automatically displayed at


those components that are actuated in the circuits initial position.

Cam switch

In Edit Mode, the cam switch is automatically displayed at those


mechanically operated way valves that are actuated in the circuits
initial position.

Text

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 561
The concept of text components in FluidSIM gives the user a way in
which to describe components in diagrams, assign identification
texts, or to provide commentary on the diagram. The text and the
appearance of text components can be customized to the users
liking.

State diagram

The state diagram records the state quantities of important compo-


nents and depicts them graphically.

Terminal assignment diagram

The terminal assignment diagram list automatically creates termi-


nals in the electrical circuit and displays the allocation in a table.

Functional diagram

With the functional diagram editor, functional diagrams e.g. dis-


placement-step diagrams can be created.

Parts list

The parts list component creates from the components of a circuit


diagram a table, which contains for each component its designation
and its description.

Rectangle

Rectangles are graphic primitives, which can also be used within


circuit diagrams.

562 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Ellipse

Ellipses are graphic primitives, which can also be used within circuit
diagrams.

Bitmap

In FluidSIM images, as with all other components and objects, can


be inserted, positioned, moved, rotated and mirrored. In addition,
images such as rectangles and ellipses are freely scalable.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 563
Learning, Teaching, and Visualizing Technologies

Chapter 22
22. Learning, T eachi ng, a nd Visual izi ng Technol ogies

Beside the creation and simulation of electro-fluidic circuit dia-


grams, FluidSIM also supports teaching basic knowledge. This
knowledge is presented in the form of texts, overview pictures,
sectional views, exercises, and educational films. Functions that
realize the selection of this instruction material are found under the
Didactics menu.

One group of these functions refers to information about single,


selected components. Another group of functions refers to ordered
overviews of the didactics material, allowing the selection of an
interesting topic. Finally, it is also possible to select and link to-
gether arbitrary topics into so-called Presentation... .

Appendix Component Library and Didactics Material offer a


complete and concise summary of the instructional material in
FluidSIM.

The following sections contain a description of the functions found


under the Didactics menu.

22.1 Information about Single Components

The first three entries under the Didactics menu refer to selected
components and are context sensitive. More precisely:

When a component in the current circuit diagram window is select-


ed, or all selected components are of the same type, the menu
entry Component description will be enabled.

564 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
22.1.1 Component Descriptions

All components possess a page with a technical description. This


page contains the diagram symbol for the component according to
the DIN standard (Deutsche Industrienorm), a textual description
of the components function, the designations of the connections,
and a listing of the adjustable parameters along with their value
ranges.

You will find a photograph of the real-life part provided for most
components. In the case that a component cannot exist singularly
in a real system, FluidSIM displays a photo of the assembly group
that this component belongs to. Examples for such components
include the indicator light, relays, switches, and the electrical
power supply. Components, that do not exist in reality, simply have
no photo. Examples include the text component and the distance
rule.

Select the one-way flow control valve and click on the menu
item Component description under the Didactics menu.

The following page opens:

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 565
Figure 22/1: Technical page of the one-way flow control valve

566 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 22/2: Technical page of the throttle check valve

Under the heading Related topics, but also when appropriate in the
component description, cross references for related instruction
material and components are defined. By clicking on a cross refer-
ence, the related page will automatically be displayed.

22.1.2 Component Illustrations

Component illustrations provide useful information relating a


components function. This may include a sectional view of the
component, but also illustrations of the components usage within
a circuit diagram. For several components, their sectional view can
be animated like a cartoon.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 567
Select an air motor (4/2-way hand-lever valve in case of hy-
draulic version) and click on Component description under
the Didactics menu.

The following dialog box appears:

568 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 22/3: Page component-specific topics

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 569
Figure 22/4: Dialog box with component-specific topics

Please click the line with the relevant topic [35] Air
motor (hydraulics: [104] 4/2-way valve, two
pistons (1) ).

The following picture appears:

570 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 22/5: Function illustration of a air motor

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 571
Figure 22/6: Function illustration of a 4/2-way valve

Often it is easier to understand the functional nature of a compo-


nent, when its behavior is visualized through the use of animation.
For this reason, several components possess different sectional
views showing the component at different states. These sectional
views can be animated in much the same way as a flip book.

Please mark a quick-exhaust valve(hydraulics: 3-way pressure


reducing valve)and click the menu option Didactics Compo-
nent description to open the window with the component de-
scription. Now click the link with the function illustration [87]
quick exhaust valve (hydraulics: [84] 3-way pressure reducing
valve)

This function illustration can be animated.

Click on or Execute Start to start the animation.

572 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
An animation can be frozen with or by clicking on Pause in
the Execute menu. or Execute Stop stops an animation,
whereas or Execute Reset restarts an animation.

22.2 Selecting Didactics Material from a List

The entries Tutorial Simulating with FluidSIM' , Component


Library and Didactics Material under the Didactics menu
present the didactics material of FluidSIM organized in the form of
overview pages. From these pages topics can be chosen and
viewed independently of the current window and possibly selected
components.

22.2.1 Tutorial

Below this menu option you can launch the tutorial Simulating
with FluidSIM, which contains a variety of interesting experiments
and an excursus. By means of these useful examples you will get to
know the possibilities of simulating with FluidSIM. Furthermore, for
the most important components the mathematic models used in
FluidSIM are also described.

Please click the menu option Didactics Tutorial Simulating


with FluidSIM' to open the tutorial.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 573
Figure 22/7: Tutorial (Pneumatics)

574 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 22/8: Tutorial (Hydraulics)

On the right-hand side the hierarchical directory is displayed. By


double-clicking the directory symbols you may list off or close the
applicable subsections. Clicking a page symbol will display the
contents of the page in the open window.

22.2.2 Component Library

Below the menu option Component Library you will find descrip-
tions and photos of all FluidSIM -components.

Click a menu option Didactics Component Library to open


the help pages of the component library.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 575
Figure 22/9: Component Library (Pneumatics)

576 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 22/10: Component Library (Hydraulics)

22.2.3 Didactics Material

FluidSIM, alongside the tutorial and the component reference,


contains further didactics material particularly useful for group
work. Moreover, here you will find educational films, provided you
have copied them onto the hard disk during the installation. If you
havent installed the film files, you may choose a chapter via the
menu option Didactics Educational Film... to view the applicable
film from the included video-CD.

Click the menu option Didactics Didactics Material to open


the overview of the didactics material.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 577
Figure 22/11: Didactics Material (Pneumatics)

578 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 22/12: Didactics Material (Hydraulics)

22.3 Presentations: Combining Instructional Material

Sometimes you may want to examine a topic from different angles


or combine individual topics into a lesson. For this purpose
FluidSIM offers the concept entitled Presentation... .

There are a number of already prepared presentations, which can


be found on the FluidSIM installation disks. However, editing
presentations or creating new presentations is also possible with
FluidSIM. All presentations can be found under Presentation... in
the Didactics menu.

Click on Didactics Presentation... .

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 579
The following dialog box appears:

580 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 22/13: Dialog box for selecting and editing presentations
(Pneumatics)

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 581
Figure 22/14: Dialog box for selecting and editing presentations
(Hydraulics)

Presentations This field contains a list of already created presentations.

New presentation... Clicking on New presentation... opens a second dialog box for
the creation of a new presentation.

Edit presentation... Clicking on Edit presentation... opens a second dialog box to


begin editing a presentation.

Preview When the Preview setting is activated, the picture that pertains to
the selected presentation appears underneath the topics list.

Click on New Presentation to open the following dialog box.

582 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 22/15: Dialog box for editing presentations (Pneumatics)

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 583
Figure 22/16: Dialog box for editing presentations (Hydraulics)

Description In this text field a short description of the presentation can be


entered. This text may consist of up to 128 characters and will
appear with the other presentations, the next time the presentation
dialog box is opened.

Available topics This field contains a list of all available topics dealing with Pneu-
matics basics, Hydraulics basics, Working principle, and
Exercise. Moreover, there exist two pictures that can be used to
announce a refreshment and a lunch break respectively. A double
click on a line in the Available Topics list inserts this line in the
Selected topics list above the highlighted bar. In this way a
presentation can be created or altered. Moreover, a user can inte-
grate his own circuit diagrams, DXF files, BMP- and WMF-picture
files, or even multimedia files such as sounds or video clips. To do

584 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
so, click on User file: A dialog box opens that allows for the
selection of the desired data source on the file system.

Selected topics This field contains a list of topics chosen for the current presenta-
tion.

Add Clicking on Add is the same as double clicking a line in the


Available topics list: The selected line in Available topics will
be inserted in the Selected topics list.

Delete Clicking on Delete deletes the selected line of the Selected


topics list.

Preview When the Preview setting is activated, the picture that pertains
to the selected topic appears underneath the respective list.

Within both topics lists the highlighted bar can be moved using the
arrow keys. Maybe it will be necessary to click and select the list
you want to work with. After creating a new presentation and clos-
ing the dialog box by clicking on &OK , FluidSIM asks you to
name the presentation file. Presentation files have the extension
.shw and are located in the subdirectory shw under the installa-
tion directory.

22.4 Extended Presentations in the Microsoft PowerPoint


Format

The hydraulics version of FluidSIM contains an additional large set


of presentations written in the Microsoft PowerPoint Format. To use
these presentations, PowerPoint must not be installed on your PC
since FluidSIM installs the necessary viewer at its installation time.

Click on Extended Presentation... to open the dialog box of a


presentation.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 585
Figure 22/17: Selection of an extended presentation

Select the item Actuators to open the related presentation in


full screen mode.

Most of the topics form a picture sequence, which can be viewed in


a single-step manner using the left mouse button or the spacebar.

Move two single steps forward in the current presentation.

586 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Figure 22/18: Actuators

When clicking the right mouse button, a context menu is opened by


which, among others, the presentation can be closed or particular
pictures picked out. The files of the extended presentations are in
the subdirectory ppx of the FluidSIM installation. You can add
new PowerPoint presentations on your own by copying the related
files (format: ppt or pps) into the ppx -directory. Like the
other didactics material (illustrations of function, component pho-
tos, circuit drawings, educational films, etc.), the PowerPoint
presentations can linked and used within presentations (cf. Section
Presentations: Combining Instructional Material).

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 587
Didactics Material Survey (Pneumatics)

Chapter 23
23. Didactics Material Survey (Pne umatics)

This chapter provides a comprehensive listing of those parts of the


didactics material in FluidSIM that are not covered by chapter The
Component Library The Component Library . Basically, this mate-
rial consists of the components' behavior illustrations, the anima-
tions, the exercises, and the educational films, which all can be
activated under the Didactics menu. The subsequent sections
are arranged thematically. The icon indicates that an animation
exists for the related topic. The last section gives an overview of the
educational films.

23.1 Basics

[1] Pneumatic system structure and signal flow

A pneumatic system can be broken down into a number of levels


representing the hardware and signal flow from the energy source
to the actuating devices.

The topic highlights the relationship between signals, levels


and elements in a pneumatic system.

[2] Circuit diagram and pneumatic elements

Circuit diagrams are drawn in such a way that signals, for instance
energy or potential values, are oriented downwards. The number-
ing of the components is derived from their respective function in
the diagram.

The topic highlights the various levels in a circuit.

588 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
[3] Designating the elements, circuit diagram

This topic shows the relationship between levels in a circuit.

[4] Designating the elements, circuit diagram

The figures contrasts the position of a roller lever valve (initial


position: actuated by the cylinder) in a circuit diagram and its
physical setup in a plant.

[5] Designating the elements, circuit diagram

The figures contrasts the position of a roller lever valve (initial


position: not actuated) in a circuit diagram and its physical setup in
a plant.

[6] Designating the elements, circuit diagram

All elements should be shown in the circuit diagram in the initial


position. If valves have been drawn with an actuated initial posi-
tion, this fact is indicated for example by an arrow, or for a limit
switch, by drawing the cam.

Explain the differences between the following terms: initial


position and starting position.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 589
23.2 Supply elements

[7] Symbols of energy and supply components, supply and ser-


vice equipment

The Symbols are from the DIN ISO 1219 Circuit symbols for fluidic
power components and systems. The symbols for the energy
supply system can be represented as individual components or as
combined elements.

Compare the symbols with the combined symbols (topic 8).

[8] Symbols of energy and supply components, combined sym-


bols

In general where specific technical details are to be given, such as


requirements for non-lubricated air or micro-filtering, the complete
detailed symbol should be used. If a standard and common air
supply is used for all components, the simplified symbols can be
used.

Compare the symbols with the previous topic.

[9] Air service unit

The filter is normally combined with the pressure regulator and


lubricator to form a compressed air service unit. The selection of
the correct filter plays an important role in determining the quality
and performance of the control system which is to be supplied with
compressed air.

Refer to topic 10 for construction of the filter.

590 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
[10] Compressed air filter

The compressed air passes through a baffle plate in the filter bowl.
The air is rotated, and the heavier dust particles and water droplets
are spun by centrifugal force against the inner wall of the filter bowl
and run down the wall of the housing. The air which has been
precleaned then passes through the filter element.

The bowl must be emptied daily to prevent overflow.

[11] Air drying, low temperature

The lower the dew point the more the water will condense and
reduce the amount entrapped in the air. Using refrigeration meth-
ods, it is possible to achieve dew points of between 2{C} and
5{C}.

Compare with absorption and adsorption drying.

[12] Air drying, absorption

Absorption drying is a purely chemical process. The moisture in the


compressed air forms a compound with the drying agent in the
tank. This causes the drying agent to break down; it is then dis-
charged as a fluid at the base of the tank. The drying agent must be
replenished at a rate which is dependent on the compressed air
temperature, water content and flow rate.

Compare with adsorption drying.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 591
[13] Air drying, adsorption

The lowest equivalent dew points (down to -90{C}) can be


achieved by means of adsorption drying. In this process, the com-
pressed air is passed through gel and the water is deposited on the
surface, i.e. it is adsorbed.

Compare with absorption drying.

[14] Air lubricator

As a rule, the compressed air which is generated should be dry and


free of oil. For some components, lubricated air is damaging, for
others, it is undesirable, and for power components, it may in
certain cases be necessary. Lubrication of the air should therefore
be limited to the sections of the plant which require it.

Refer to picture of topic 9 for general arrangement.

[15] Air lubricator

Air passing through the lubricator causes a pressure drop between


the oil reservoir and the upper part of the lubricator. This pressure
difference forces the oil upwards through a tube and it then drips
into a nozzle which can be seen through an inspection glass. The oil
is atomized and carried along by the air stream.

It is necessary to carefully adjust the oil discharge rate.

592 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
[16] Pressure regulator with vent hole

The purpose of the regulator is to maintain the operating pressure


(secondary pressure) virtually constant regardless of fluctuations in
the line pressure (primary pressure). When air consumption in-
creases, the operating pressure drops and the spring opens the
valve. If the pressure on the secondary side increases considerably,
the center-piece of the diaphragm then opens and the compressed
air can flow to atmosphere through the vent holes in the housing.

[17] Delivery

Due to the pressure losses in the system, the compressor should


deliver between 650 and 700 kPa (6.5 and 7 bar). The operating
components of the system should be regulated to between 500 and
600 kPa (5 and 6 bar) for economic use. The receiver is used to
even out fluctuations in pressure due to demand. The drainage
points are at the lowest points.

The gradient should be away from the compressor.

[18] Piston compressor

The piston compressor is widely used. Multi-stage compressors are


required for compressing to high pressure. The drawn in air is
compressed by the first piston, cooled and then compressed fur-
ther by the next stage.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 593
Discuss the advantages and disadvantages of piston compres-
sors.

[19] Axial flow compressor

Flow compressors produce large volumes of air at small increases


in stage pressure. The air is accelerated by the blades of the com-
pressor but there is only a small increase in pressure.

The kinetic energy is converted to pressure energy.

[20] Distribution

For ease of maintenance, repair or extension of the air network, it is


advisable to sub-divide the network into individual sections by
means of shut-off valves. Branches with T-pieces and manifolds
with plug-in couplings make it possible to supply additional con-
suming devices as the need arises.

To discharge condensate, the pipes should be inclined 1-2 %


and include water separators at low points.

[21] Absolute pressure and atmospheric pressure

Absolute pressure is calculated from the absolute zero mark. Below


atmospheric pressure the pressure is in the vacuum range. The

594 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
atmospheric pressure fluctuates but is approximately 100 kPa (1
bar).

Gauge pressure is normally that component above atmospheric


pressure and is not an absolute value.

23.3 Actuators

[22] Symbols for actuators, linear actuators

The single acting cylinder and the double acting cylinder form the
basis for design variations. The use of cushioning to reduce loads
on the end caps and mountings during deceleration of the piston is
important for long-life and smooth operation.

Refer to topics 25 - 30 for construction details.

[23] Symbols for actuators, rotary motion

Rotary actuators are divided into continuous motion and limited


angle of rotation. The air motor is normally a high speed device
with either fixed or adjustable speed control. Units with limited
angle of rotation are fixed or adjustable in angular distance. The
rotary actuator may be cushioned depending on the load and speed
of operation.

Refer to topics 34 and 35 for construction details.

[24] Control of a single acting cylinder

The position rod of a single acting cylinder is to move forward when


air is applied. A valve is to create a signal when a push-button is
released. The animation shows the operation of the push-button
and the extension of the cylinder. Pressure is maintained on the

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 595
piston until the push-button is released. The next stage shows
retraction of the cylinder and the release of air via the exhaust port
of the 3/2-way valve.

The topic can be used as an intermediate stage for explanation


of the related symbols.

[25] Single acting cylinder

The cylinder requires one pneumatic connection and an exhaust


port. The exhaust port must be clear of obstructions to ensure that
the piston is not restricted by the air passage. A filter is normally
fitted to the exhaust port.

Discuss the importance of selecting the size of the cylinder to


match the load conditions.

[26] Single acting cylinder

With single acting cylinders, compressed air is applied on only one


side of the piston face. The other side is open to atmosphere. The
cylinders can perform work in only one direction. The return move-
ment of the piston is effected by a built-in spring or by the applica-
tion of an external force. The spring force returns the piston to its
start position with a reasonably high speed under no load condi-
tions. The stroke is limited by the natural length of the spring.
Single acting cylinders are therefore only available in stroke lengths
of up to 100 mm.

Compare the construction with the double acting type. Discuss


the spring size and return speed.

[27] Control of a double acting cylinder

The 4/2-way directional control valve is suitable for the control of a


double acting cylinder. Normal practice is to use the 5/2-way valve.

596 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
The cylinder motion is controlled by air in both directions of motion.
The animation shows the advance and retraction sequences as
separate phases. The fully advanced position is related as long as
the push-button is actuated.

The topic can be used as an intermediate stage for explanation


of the related symbols.

[28] Double acting cylinder

Double acting cylinders are used particularly when the piston is


required to perform a work function in both directions of motion.
The construction is in general similar to the single acting cylinder.

Refer to the large number of variants, which result from the


different designs, materials, etc.

[29] Double acting cylinder

The first sequence shows the piston rod advancing. The second
stage the retraction. The speed of advance and retraction are fairly
constant under no load conditions.

Point at the positions of cylinder body, piston cover, cylinder


cover, piston seal, piston rod, bearing bush, and scraper ring.

[30] Cushioned double acting cylinder

If large masses are moved by a cylinder, cushioning is used in the


end positions. Before reaching the end position, a cushioning
piston interrupts the direct flow of air to the outside. For the last

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 597
part of the stroke the speed is slowed to reduce impact on the
cylinder.

Discuss the different concept of throttleling the exhausting air


by means of one-way flow control valve.

[31] Cylinder seals

The various piston seal arrangements are shown. The double-cup


seal materials used are, Perbunan for -20{C} to +80{C} Viton for -
20{C} to +190{C} Teflon for -80{C} to +200{C}.

Emphasize correct temperature range selection for reliability.

[32] Mounting arrangements for cylinders

The type of mounting is determined by the manner in which the


cylinder is to be fitted to a machine or fixture. The cylinder can be
designed with a permanent type of mounting if it does not have to
be altered at any time. Alternatively, the cylinder can utilize adjust-
able types of mounting which can be altered by using suitable
accessories on the modular construction principle.

Discuss application examples for each type of mounting.

598 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
[33] Tandem double acting cylinder

This design features the characteristics of two double acting cylin-


ders forming a single unit. This increases the effective piston area
of the unit for high force applications. It is suitable for applications
where a large force is required but the cylinder diameter is restrict-
ed.

Compare the double acting cylinder in topic 29.

[34] Semi-rotary actuator

The rotary actuator is compact with high torque ratings. The force is
transmitted to the drive shaft by a rotary vane. The range of angular
movement is adjustable with end stops. The angle can be adjusted
between 0 and 180. The adjustable stop system is separate to the
rotary vanes. This allows force to be absorbed by the stop blocks.
At the end positions, impacts are cushioned by elastic cushioning
rings.

Discuss the mounting arrangements for the actuator. Discuss


applications for the rotary actuator.

[35] Air motor

Devices which transform pneumatic energy into mechanical rotary


motion, with the possibility of continuous motion. They are catego-
rized into the groups of piston motors, sliding vane motors, gear
motors and turbines.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 599
Discuss applications for the air motor.

23.4 Directional control valves

[36] Symbols for directional control valves (1)

The directional control valve is represented by the number of ports


and the number of switching positions. Additional information is
required to fully describe the symbol function, including the meth-
ods of actuation and special flow path characteristics.

Compare the full range of symbols for directional control


valves.

[37] Symbols for directional valves (2)

Each valve position is shown as a separate square. The designation


of the ports is important when interpreting the circuit symbols and
the valve as fitted to the physical system.

Compare the full range of symbols for directional control


valves.

[38] Designation of connections

The designations for directional control valves are in accordance


with ISO 5599-3, edition 1990. Prior to this a lettering system was
utilized.

Discuss the examples and emphasize the numbering systems.

600 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
[39] Methods of actuation (1)

The methods of actuation of pneumatic directional control valves is


dependent upon the application. The methods of actuation include
manual, mechanical, pneumatic, electrical and combined.

Discuss the actuation and return actuation methods.

[40] Methods of actuation (2)

When applied to a directional control valve, consideration must be


given to the method of initial actuation of the valve and also the
method of return actuation. They are both shown on the symbol
either side of the position boxes. There may also be additional
methods such as manual overrides separately indicated.

Discuss the actuation and return actuation methods.

[41] 3/2-way valve, ball seat

A spring forces a hemisphere against the valve seat preventing the


compressed air from flowing from the air connection 1 to the work-
ing line 2. Initially port 1 is blocked and the output port 2 is ex-
hausted through the stem of the plunger. Actuation of the valve
plunger causes the sealing element to be forced away from the
seat. In doing this, the opposing force of the reset spring and that
generated from the compressed air must be overcome. The air
supply is then open to the output side of the valve and a signal is
generated.

Compare the symbol and the valve construction. Compare the


construction of the disc seat valve.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 601
[42] 3/2-way valve, ball seat

The ball seat valve is compact with the possibility of fitting various
types of actuating heads. The limitation for directly actuated valves
is the force required to operate the stem. If the flow rate required is
very high, the valve ball will have a large working area. This re-
quires a large operating force. This limits the size of valve for this
design.

The load on the stem is dependent on the size of valve.

[43] 3/2-way valve, disc seat, normally closed

The valve is constructed on the disc seat principle. The response


time is short and a small movement results in a large area being
available for air flow. Valves of the single disc seat type are non-
overlapping. Using this topic, discuss the term blocked normal
position. When operated slowly, there is no loss of air. A 3/2-way
valve with flow blocked between ports 1 and 2 in the normal condi-
tion, is referred to as a normally closed valve. The valves are insen-
sitive to dirt and thus have a long service life. Explain the term
non-overlapping with this figure and the animation.

The animation sequence shows the operation of the 3/2 way


valve. The first sequence describes the actuation and the sup-
ply of a signal from 1 to 2. The second sequence shows the
closing of the disc seat and the release of air from 2 to 3 which
exhausts to atmosphere.

602 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
[44] 3/2-way valve, disc seat, normally open

A 3/2-way valve with free flow between ports 1 and 2 in the normal
condition, is referred to as normally open. Valves can be operated
manually, mechanically, electrically or pneumatically. The configu-
ration of the valve head is changed to meet the actuation method.
Upon operation of the actuating stem, the disc seat is sealed and
air supply port 1 is blocked. The air at port 2 is exhausted to at-
mosphere via port 3.

Note the change of construction compared to the normally


closed valve topic 43.

[45] 3/2-way valve, single pilot, normally closed

The pneumatically operated 3/2-way valve is operated by a directly


acting signal at port 12. This is referred to as a single pilot valve
since there is only one control signal and the valve has a spring
return. A signal is applied at port 12 and the valve plunger is moved
against the reset spring. The connections 1 and 2 are then inter-
connected creating a signal 2. The pressure at port 12 must be
sufficient to move the disc against the supply pressure.

Note the pneumatic symbol shows direct application of the


signal at port 12. Compare the construction of the valve to the
3/2-way disc seat valve topic 43.

[46] 3/2-way valve, single pilot

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 603
The valve ports are labeled to ensure the correct connections are
made. The pilot valve is available in a range of sizes depending
upon the flow rate.

Note the need to designate and label the ports.

[47] 3/2-way valve, internal pilot, roller operated

This type of valve can be used as either a normally closed valve or


as a normally open valve by exchanging connections 1 and 3 and
rotating the actuating head 180 degrees. The force required on the
roller lever is small due to the pilot operation.

Show the requirements to alter the valve configuration.

[48] 3/2-way valve, internal pilot, normally closed

To avoid high actuating force, mechanically controlled directional


valves can be equipped with an internal pilot valve to assist open-
ing. A small hole connects the pressure connection 1 and the pilot
valve. If the roller is operated, the pilot valve opens. Compressed
air flows to the main piston and actuates the main valve disc.

The symbol shows the roller operating a pilot signal.

[49] 4/2-way valve, disc seat

The valve is robust. Two stems directly operate the disc seats. The
load required to move the stems may be large for high flow rate
valves.

604 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Compare the construction with the 3/2-way valve.

[50] 4/2-way valve, disc seat

The 4/2-way valve has four ports and two positions. A disc seat
4/2-way valve is similar in characteristic to the combination of two
3/2-way valves, one valve normally closed and the other normally
open. The plungers can be operated by an auxiliary mounted device
such as a roller lever or push-button. When the two plungers are
actuated simultaneously, 1 to 2 and 4 to 3 are closed by the first
movement. By pressing the valve plungers further against the
discs, opposing the reset spring force, the passages between 1 to 4
and from 2 to 3 are opened.

Show the similarities to the 3/2-way valve construction. Dis-


cuss the valve overlap.

[51] 4/3-way valve, mid-position closed

The 4/3-way valve has four ports and three positions. An example
of the 4/3-way valve is the plate slide valve with hand or foot
actuation. By turning two discs, channels are interconnected with
one another.

Compare the symbol with the valve construction.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 605
[52] 5/2-way valve, longitudinal slide valve

The valve can be mounted onto a common sub-base for supply and
exhaust air. This compact arrangement also ensures adequate flow
is available to the valve.

Discuss the DIN ISO 5599/1 standard for 5 port valves.

[53] 5/2-way valve, longitudinal slide valve

The 5/2-way valve has five ports and two positions. The 5/2-way
valve is used for the control of cylinders primarily as a final control
element. In pneumatic valves, the gap between spool and housing
bore should not exceed 0.0020.004 mm. The valve is shown here
with pilot pressure applied at port 12. To avoid damage to seals,
the ports can be distributed around the circumference of the hous-
ing. The actuation travel is considerably larger than with seat
valves. The valve is shown here with pilot pressure at 14.

Discuss the load conditions on the O-rings. Compare the con-


struction with the disc seat valve.

[54] 5/2-way valve, suspended disc seat

A method of sealing the 5/2-way valve is to use a suspended disc


seat with a relatively small switching movement. The disc seat seal
connects the 1 port to either the 2 port or the 4 port. The 5/2-way
double air pilot valve has the characteristic of memory control. The
last switched position is retained until a new switching position is
initiated by a unique pilot signal from the opposite side. There are

606 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
two manual override buttons to manually operate valve spool. The
animation shows the two switched positions. The air pilot signals
are applied from both directions. The manual override operations
are also shown. The manual overrides are used to manually actuate
the valve or initialize the valve position.

Compare the suspended disc seat construction to the longitu-


dinal slide principle topic 53. Explain the working principle of
the manual override button and its related diagram symbol.

[55] 5/3-way valve

The 5/3-way valve has five ports and three positions. Signals ap-
plied at ports 14 or 12 operate the valve. If the valve is not actuated
it is closed in the mid-position. After actuation via a pilot signal at
port 14 air flows from 1 to 4. Port 2 exhausts via 3. After actuation
via a pilot signal at port 12 air flows from 1 to 2. Port 4 exhausts via
port 5.

Show the three valve positions.

[56] Memory circuit, 5/2-way bistable valve

The piston rod of a double acting cylinder is to advance when a 3/2-


way push-button valve is actuated. The cylinder is to remain ex-
tended until a second push-button is actuated. The cylinder is to
then return to the initial position. The speed of the cylinder is to be
adjustable in both directions.

Discuss the memory characteristic of the bistable valve.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 607
[57] Memory circuit, 5/2-way bistable valve

Signals initiated by the push-button signaling devices can be of


short or pulse duration due to the memory characteristics of the
bistable valve. Upon operation of push-button 1S1, a 1-signal is
generated at port 14 of the control valve 1V3. The 5/2-way memory
valve switches and the cylinder 1A1 advances.

The circuit is shown at the first operation of the button.

[58] Memory circuit, 5/2-way bistable valve

When the push-button 1S1 is released, the signal at port 14 is


exhausted. The valve 1V3 remains in the current position. The last
position is retained until a new input signal is given.

Compare the sequence of operation.

[59] Memory circuit, 5/2-way bistable valve

The valve 1V3 remains in the current position until the push-button
1S2 is operated. The cylinder then retracts. The cylinder remains
retracted until a new signal is generated at port 14 by the valve
1S1.

Compare the sequence of operation.

[60] Memory circuit, 5/2-way bistable valve

The flow control valves throttle the exhausting air in both directions
of piston motion. The cylinder remains retracted until a start signal
is generated at port 14 by the valve 1S1. The 5/2-way valve re-
mains in the current position with air supplied continuously to the
return side of the cylinder.

Discuss the situation when both 1S1 and 1S2 are operated
together.

608 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
[61] Direct control, unactuated

A single acting cylinder of 25 mm diameter is to clamp a component


when a push-button is pressed. As long as the push-button is
operated, the cylinder is to remain in the clamped position. Since
the cylinder is the only working element or actuator in the circuit, it
is designated 1A1. The final control element that advances the
cylinder is designated 1S1.

Discuss the circuit layout standard, numbering and operation.


Note the circuit is shown in the initial state.

[62] Indirect control (unactuated)

A large diameter single acting cylinder is to extend upon operation


of a push-button valve. The valve is situated at a remote and dis-
tant position. The cylinder is to retract once the remote push-
button is released. The signal at the pilot port 12 remains as long
as the push-button is held down. This is an indirect push-button
control of the cylinder. If the push-button is released, the spring
return closes the 3/2-way valve and removes the pilot signal at the
control valve.

Discuss the circuit layout standard, numbering and operation.


Note the circuit is shown in the initial state.

[63] Exercise: Direct control of a double acting cylinder Problem

A double acting cylinder is to advance when a push-button is oper-


ated. Upon release of the push-button, the cylinder is to retract.
The cylinder is of small bore (25 mm diameter) requiring a small
flow rate to operate at the correct speed.

[64] Exercise: Direct control of a double acting cylinder Solution

The control valve for a double acting cylinder can be selected as a


4/2 way or a 5/2 way valve. In this case, since the cylinder has a

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 609
small capacity, the operation can be directly controlled by a push-
button control valve with spring return. On operating the push-
button, the air passes through the valve from port 1 to the port 4
and advances the piston rod. On release of the push-button, the
valve spring returns the control valve to its initial position and the
cylinder retracts. Air escapes from the cylinder via the exhaust port.
Since the cylinder is the only working element or actuator in the
circuit, it is designated 1A1. The final control element that advances
the cylinder is designated 1S1.

[65] Exercise: Direct control of a double acting cylinder Note

If the push-button is pressed for a very short period, the cylin-


der only partially advances and then retracts, since the spring
resets the control valve as soon as the push-button is released.
In order to achieve full extension in this case, the push-button
must be held down until the cylinder moves fully forward.

[66] Exercise: Indirect control of a double acting cylinder Prob-


lem

A double acting cylinder is to advance when a push-button is oper-


ated. Upon release of the push-button the cylinder is to retract. The
cylinder is 250 mm diameter and consumes a large volume of air.
For controlling cylinders at high speed or of large diameter large
size control valves should be used. The operating force to actuate
the valve may be relatively large and in this case indirect control is
preferable.

[67] Exercise: Indirect control of a double acting cylinder Solu-


tion

Operating valve 1S1 supplies a pilot signal to port 14 of control


valve 1V1. This generates a 1-signal at the outlet 4 and the cylinder
advances. If the push-button is released the return signal is sup-
plied via port 2 of valve 1V1 and the return air is vented via exhaust
port 5. If the push-button is released before the cylinder fully ad-

610 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
vances, the cylinder immediately returns to the initial position. The
control valve requires a sustained signal for it to remain operated.

Explain the benefits of indirect control: The required actuating


force is reduced, the working lines can be kept short, since the
actuator can be mounted close to the cylinder, and the signal-
ing element can be small since it has to generate only the sig-
nal for actuating the control valve.

[68] Exercise: Indirect control of a double acting cylinder Note

The supply line can be short since the control valve can be
mounted close to the cylinder. The other advantage is that the
signal element (i.e. push-button 3/2 way valve) can be small,
as it only provides a signal to operate the control valve and is
not required to operate the cylinder directly.

23.5 Shutoff valves

[69] Non-return valves

The non-return or check valve will open due to the supply pressure
exceeding the resistance of the spring (if fitted) and the inertia of
the valve. The non-return valve is the basis for development of
many combined components. The shuttle valve, two pressure valve
and quick exhaust valve incorporate features of the non-return
valve.

Indicate the valves that include the non-return function.

[70] Non return valve

Non return valves can stop the flow completely in one direction. In
the opposite direction the flow is free with a minimal pressure drop

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 611
due to the resistance of the valve. The one-way blocking action can
be effected by cones, balls, plates or diaphragms.

Discuss the relationship between pressure to open and the


spring size.

[71] Two pressure valve

The two pressure valve has two inputs 1 and one output 2. The two
pressure valve is used mainly for interlocking controls, safety
controls, check functions or logic operations. The application of a
signal at a single input produces no pressure at output 2. If pres-
sure is applied at both inputs 1, the signal which is last applied
passes to the output 2. The two pressure circuit is equivalent to
two input signaling devices in series, i.e. one after the other.

Refer to topics 72 - 74 for the circuit example. Discuss the


advantages of the shown solution against series connection.

[72] Circuit: Two pressure valve I

The piston rod of a double acting cylinder is to advance when a 3/2-


way push-button valve and a roller lever valve are actuated. If
either of the actuations is released, then the cylinder is to return to
the initial position.

Discuss the circuit layout standard, numbering and operation.

[73] Circuit: Two pressure valve II

The inputs of the two pressure valve is connected to the outputs of


the two 3/2-way valves. Upon operation of the push-button 1S1, a
signal is generated at the left side of input 1 of the two pressure
valve. The signal is blocked by the two pressure valve. No output is
given at 2.

612 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Discuss the logic function AND. Refer to the following topic
for additional conditions.

[74] Circuit: Two pressure valve III

If the roller lever valve 1S2 is also operated, then the two pressure
valve will produce a 1-signal at port 2 which operates the control
valve, via pilot port 1V1, against the return spring and the cylinder
advances.

Compare this topic to topic 73.

[75] Exercise: The logic AND function, the two pressure valve
Problem

A transfer station removes a product from a conveyor belt. If the


product is detected as present and if the operator presses the
push-button, the pick-up cylinder 1A1 advances. The product is
sensed by a 3/2 way roller lever valve. Upon release of the push-
button, cylinder 1A1 is to retract to the initial position. The operat-
ing condition for the pick-up cylinder to advance is a logic AND
function between the product sensor and the operator push-
button. Therefore if a two pressure valve is used to combine the
signals from the sensor and push-button the logic conditions can
be met.

[76] Exercise: The logic AND function, the two pressure valve
Solution

The two pressure valve is connected between the outlet lines of the
two 3/2 way valves. Operating the push-button, a 1-signal is gen-
erated at left input 1 of the two pressure valve. Once the part is
sensed as present, the 3/2 way roller valve generates a second 1-
signal, this time at the right input 1 of the two pressure valve. A
signal is passed through to port 2. This signal operates the control
valve pilot signal 14 against the spring return and the cylinder
advances. If either of the two signals created by the 3/2 way valves
is set to zero, the two pressure valve will release the 14 signal back
through the exhaust port of one of the 3/2 way valves. The return

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 613
spring in the control valve then switches the control valve to the
initial position. The control valve outlet port 2 is active and with
outlet port 4 exhausted to atmosphere the cylinder retracts. The
control valve can be a 4/2 or 5/2 way valve and can be sized to suit
the flow rate required for the cylinder speed.

[77] Exercise: The logic AND function, the two pressure valve
Note

Discuss also the advantages of the shown solution against series


connection.

[78] Shuttle valve

This non-return element has two inputs 1 and one output 2. If


compressed air is applied to one input, the valve seat seals off the
opposing input and the air flows to the output 2. Note the similarity
in construction to the two pressure valve.

Compare the two pressure valve construction topic 71.

[79] Circuit: Shuttle valve I

If the condition states that either of two push-buttons are to ad-


vance a cylinder, the inexperienced designer may attempt to use a
junction for the output signals of 1S1 and 1S2. The circuit is not
functional due to the escape of air through the exhaust ports of the
valves.

Discuss the sequence of circuits for the shuttle valve.

[80] Circuit: Shuttle valve II

If push-button 1S1 is operated, the air escapes to atmosphere


through the exhaust port of 1S2. The air takes the easiest path and
the pressure will be very low and inadequate to operate the valve

614 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
1V1. This is an inadequate solution to the problem. A shuttle valve
is required.

Compare the topic with the previous one.

[81] Circuit: Shuttle valve III

The piston rod of a double acting cylinder is to advance when either


of two 3/2-way push-buttons are actuated. If both push-buttons
are then released, the cylinder is to retract. The shuttle valve is
incorporated at the junction and the circuit now functions correctly.

Note the function of the ball in the shuttle valve acting as a


non-return valve.

[82] Circuit: Shuttle valve IV

The shuttle valve is connected to the junction between the two 3/2-
way push-button valves. Upon operation of one of the push-
buttons, a signal is generated at the X or Y port of the shuttle valve
and an output signal is emitted at port 2. The cylinder advances.

Compare the topic with the previous one.

[83] Exercise: The logic OR function, the shuttle valve Problem

A cylinder is used to transfer parts from a magazine. If either a


push-button or a foot pedal is operated, then the cylinder is to
advance. Once the cylinder has fully advanced, it is to retract to the
initial position. A 3/2 way roller lever valve is to be used to detect
forward end position of the cylinder.

[84] Exercise: The logic OR function, the shuttle valve Solution

The shuttle valve is connected to the junction between the two


manual 3/2 way valves. Upon operation of one of the manual 3/2
way valves, a 1-signal is generated at either input 1 of the shuttle

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 615
valve. This signal passes through the shuttle valve and is emitted at
port 2. This operates the control valve via pilot port 14, and the
cylinder advances. A limit valve 1S2 senses that the cylinder has
fully extended. Pilot signal 2 from valve 1S2 actuates the 5/2 way
valve via port 12 and the cylinder retracts. The signal at port 12 is
only effective, if the opposing signal at port 14 is released. If both
of the signals produced via the push-button valves are set to zero,
then the shuttle valve will release the pilot signal 14 back through
the exhaust port of one of the 3/2 way valves. In other words, both
the push-button and the foot pedal must be inactive for retraction
to occur. The control valve can be a 4/2 way or 5/2 way valve and
can be sized to suit the flow rate required for the cylinder speed.

[85] Exercise: The logic OR function, the shuttle valve Note

The necessity of the shuttle valve can be explained with topic


79.

[86] Quick exhaust valve

To reduce resistance to flow, the air is expelled to atmosphere


through a large orifice thus increasing cylinder piston speed. The
valve is normally silenced so as to reduce exhaust air noise.

[87] Quick exhaust valve

Quick exhaust valves are used to increase the piston speed of


cylinders. Lengthy return times can be avoided, particularly with
single acting cylinders. To reduce resistance to flow, the air is
expelled to atmosphere close to the cylinder and through a large
orifice. In the direction 1 to 2 the air is passed freely via the open-
ing of the non-return seal. Port 3 is blocked by the disc. If air is
supplied to port 2, the disc seals port 1. Air is expelled to atmos-
phere through the large orifice 3. Mount the quick exhaust valve
directly on the cylinder, or as near as possible.

Refer to topic 88 for the circuit example.

616 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
[88] Circuit: Quick exhaust valve

A cylinder piston rod is to travel at an increased speed, utilizing the


quick exhaust valve. The forward motion of the piston rod is assist-
ed by the release of exhausting air at the quick exhaust valve. The
return stroke is unchanged due to the bypass non-return valve.

Refer to topic 70 for construction of the valve.

[89] Exercise: The quick exhaust valve Problem

A cylinder advances a forming tool on an edge-folding device. If a


sheet is detected as present and if a push-button is pressed, then
the cylinder is to advance. For rapid forward travel, the circuit
utilizes a quick exhaust valve. The forward movement folds the
edge of a flat sheet. If the push-button is released, the double
acting cylinder is to return slowly to the initial position.

[90] Exercise: The quick exhaust valve Solution

Initial position: In the initial state, the cylinder assumes the retract-
ed position. If both of the 3/2 way valves are actuated, pressure is
present at the output port 2 of the two pressure valve 1V4. This
reverses the 5/2 way control valve. The cylinder advances with air
being supplied via an unrestricted passage through the one-way
flow control valve 1V1. The actuator travels rapidly to its forward
end position since the pressure space on the piston rod side is
rapidly exhausted through the quick exhaust valve. If both 3/2 way
valves remain actuated, the cylinder remains in the forward end
position. If the push-button is released, the actuator is no longer
pressurized, since the control valve reverses via the return spring.
The actuator travels to its initial position under conditions of re-
stricted flow (valve 1V1) and therefore at a reduced speed.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 617
[91] Exercise: The quick exhaust valve Note

The quick exhaust valve should be fitted as near as possible to


the connection of the cylinder to reduce resistance to flow.

23.6 Flow control valves

[92] Flow control valves

Most flow control valves are adjustable. If the non-return valve is


fitted, then the element is a one-way flow control valve.

Discuss the flow in both directions in both cases.

[93] One-way flow control valve

The valve is generally mounted as close to the cylinder as possible.


The valve is usually provided with a locking nut to allow finite
adjustments to be regulated and then set.

[94] One-way flow control valve

One-way flow control valves influence the volumetric flow of the


compressed air. One-way flow control valves are normally adjusta-
ble and the setting can be locked in position. The influence of
speed control is in one direction only. The first sequence of the
animation shows the total cross section of the one-way flow control
valve. The animation will be shown in detail by zooming into the air
passage area.

Refer to topic 96 for the circuit example.

618 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
[95] Throttle valve

Throttle valves are normally adjustable and the setting can be


locked in position. These valves are used to regulate the speed
regulation of actuators and if possible, should be mounted directly
on the cylinder.

Compare the flow control with throttle valves and one-way flow
control valve topic 94.

[96] Supply and exhaust air throttling

Exhaust air throttling should be used with double acting cylinder


circuits. For supply air throttling, the flow valves are installed so
that the air entering the cylinder is throttled. With exhaust air
throttling, the supply air flows freely to the cylinder and the exhaust
air is throttled.

Discuss the numbering system. Even numbers relate to advanc-


ing signals and odd numbers to the retracting signals.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 619
23.7 Pressure control valves

[97] Pressure control valves

The pressure control valves are generally adjustable against a


compression spring. The sensing line for regulators is at the valve
outlet and for sequence valves the sensing is before the valve, i.e.
that pressure which is to be measured.

Compare the sensing line positions and flow arrows.

[98] Adjustable pressure sequence valve

The adjusting screw normally incorporates a look nut to set the


desired position. The valve body is fitted to a sub-base which can
frame mounted with other compact valves. Some applications for
the valve are clamping, pressing, gluing and safety interlocks.

[99] Adjustable pressure sequence valve (unactuated)

Sequence valves are installed in pneumatic controls where a specif-


ic pressure is required for a switching operation. The output signal
is transmitted only after the required operation pressure has been
reached. If the signal pressure at port 12 exceeds that set on the
spring, the valve opens. Outlet port 2 is opened only if a preset
pressure has built up in pilot line 12. A pilot spool opens the pas-
sage between ports 1 to 2.

Discuss the two elements in the control symbol. Discuss the


adjustment required to set the desired operation pressure. A
pressure gauge is required.

620 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
[100] Circuit: Pressure sequence valve

A plastic component is embossed using a die powered by a double


acting cylinder. The die is to advance and emboss the plastic when
a push-button is operated. The return of the die is to be effected
when a preset pressure is reached. The pressure is to be adjusta-
ble.

Refer to topic 99 for construction of the valve.

[101] Exercise: Pressure dependent control, embossing of plastic


Problem

A plastic component is embossed using a die and a double acting


cylinder. The die is to advance and emboss the plastic when a
push-button is operated. The return of the die is to occur when the
cylinder rod has fully advanced to the embossing position and a
preset pressure is reached. A roller limit valve is to be used to
confirm full extension. The embossing pressure is adjustable and is
indicated on a pressure gauge.

[102] Exercise: Pressure dependent control, embossing of plastic


Solution

The cylinder advances if valve 1V1 is switched by push-button valve


1S1. The pressure on the advancing side of the cylinder is fed from
a junction to the limit valve 1S2 and then in series to the sequence
valve. The signal port 12 at the sequence valve acts against the
preset compression of the adjustable spring. If the limit valve 1S2
is operated due to full extension of the cylinder and the preset
value is reached, then the sequence valve opens from 1 to 2 and
sends a pilot signal to port 12 of the control valve 1V1. The memory
valve switches and the cylinder retracts. At the same time the air
from port 4 is exhausted and the pilot signal at the sequence valve
is relieved through the limit valve.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 621
[103] Exercise: Pressure dependent control, embossing of plastic
Note

If the pressure does not reach the preset limit, then the cylin-
der will remain advanced. If the cylinder is obstructed during
extension to the forward position, the cylinder will not retract
due to the dependency upon operation of the limit vale 1S2.
The power circuit must be initialized by operating the 5/2 way
memory valve manually (via the manual overrides) with the air
off. The air can then be turned on.

23.8 Time delay valve

[104] Time delay valve, normally closed

The valve has a lock-able adjusting screw for setting time. The valve
is sized to meet the flow requirements.

Discuss the accuracy of the time delay valve.

[105] Time delay valve, normally closed

The time delay valve is a combinational valve consisting of a 3/2-


way valve, throttle relief valve and an air reservoir. The 3/2-way
valve can be a valve with normal position open or closed. The delay
time is generally 0-30 seconds for both types of valves. By using
additional reservoirs, the time can be extended. When the neces-
sary control pressure from 12 has built up in the air reservoir, the
pilot spool of the 3/2-way valve is actuated. An accurate switch-
over time is assured if the air is clean and the pressure constant.

Discuss the need for clean and stable air for accuracy. Discuss
the relationship between time delay and the reservoir size.

622 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
[106] Circuit: Time delay valve

A double acting cylinder is to glue components. The push-button


operates the clamping cylinder and trips a roller lever valve. The
cylinder is to remain fully extended for a time of 6 seconds and then
immediately retracts to the initial position. A new start cycle is only
possible after the cylinder has fully retracted. The cylinder advance
is to be slow and the retraction adjustable but fast.

Refer to topic 104 for construction of the valve.

[107] Exercise: The time delay valve Problem

A double acting cylinder is used to press together glued compo-


nents. Upon operation of a push-button, the clamping cylinder
advances and trips a roller lever valve. Once the forward end posi-
tion is reached, the cylinder is to remain for 6 seconds and then
immediately retract to the initial position. A new start cycle is only
possible after the cylinder has fully retracted and after a delay of 5
seconds. The cylinder extension is to be slow and the retraction
adjustable, but relatively fast.

[108] Exercise: The time delay valve Solution

The start conditions are the actuation of roller limit valve 1S3, a
delay of 5 seconds after the end of cycle and the operation of 1S1.
The two pressure valve 1V4 actuates the 5/2 way memory valve at
port 14. The cylinder advances at a preset speed via the flow con-
trol valve 1V2. The limit switch 1S3 is deactivated and therefore
even if the start button is still held, the signal at port 14 is exhaust-
ed by the removal of the limit switch signal, which resets the timer
1V6 until the cylinder has retracted again. The cylinder reaches the
limit valve 1S2 and produces a pilot signal for the time delay valve
1V5. The time delay valve opens port 2 if the preset time is reached.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 623
A pilot signal is produced 6 seconds after the limit valve 1S2 is
operated. The 5/2 way valve switches to the initial position and the
cylinder retracts and with speed controlled by the valve 1V1. The
roller limit valve 1S2 is deactivated and the pilot signal to the timer
1V5 is cut-off, removing the signal at port 12 of the 5/2 way valve.

[109] Exercise: The time delay valve Note

The memory valve must be positioned manually before air is


supplied to the circuit to ensure that the cylinder will be re-
tracted initially.

[110] Exercise: Memory circuit and speed control of a cylinder


Problem

A double acting cylinder is to fully advance when a push-button is


actuated and to retract after full extensions is reached (confirmed
by a roller lever valve). The cylinder is to continue forward even if
the push-button is released. Speed of the cylinder is to be adjusta-
ble.

[111] Exercise: Memory circuit and speed control of a cylinder


Solution

Operating the push-button 1S1 then advances the cylinder 1A1.


Operation of valve 1V3 produces pressure at port 14 which switch-
es the air to port 4. Once the cylinder travels to the limit valve 1S2,
a pilot signal is sent to port 12 of the control valve switching the
control valve if the push-button valve is released. If the push-
button is held operated after the cylinder has fully advanced, it will
remain advanced until valve 1S1 is released. The final control
element 1V3 is a memory valve and the last position is retained
until a unique opposing signal is received. The speed of advance
and retraction is controlled by the throttle valves 1V1 and 1V2 and
in both cases the speed control is by exhaust air throttling. If the
roller lever valve is fitted at the mid-stroke position of the cylinder,
it will advance up to the limit valve and then retract.

624 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
[112] Exercise: Memory circuit and speed control of a cylinder
Note

The memory control valve 1V3 when first fitted could be in either of
two positions 14 or 12. It is not easy to predict the position of the
valve when fitted. If a manual override button is available the valve
should be manually set to the 12 position before turning on the air
to ensure that the cylinder remains retracted initially.

23.9 Sequential circuit and signal overlap circuit

[113] Sequential circuit, distance-step diagram

Confirmation is required that cylinder 2A1 is retracted before start


of the cycle. The sequence is, A+ B+ A- B-. The valves 2S2 and 1S3
are initially operated. There is no signal overlap at the final control
elements 1V2 and 2V2.

Discuss the relationship between the circuit and the distance-


step diagram.

[114] Sequential circuit

A sequential circuit has the following characteristics; when a 3/2-


way push-button valve is operated, cylinder 1A1 extends. Confirma-
tion is required at each step of the sequence. The sequence is A+
B+ A- B-.

There is no signal overlap with the circuit.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 625
[115] Signal overlap circuit I

It is necessary to identify the points in the circuit where signal


overlap occurs on the 5/2-way valves 1V2 and 2V2. With this dis-
tance step diagram the circuit design using roller valves cannot
operate due to signal overlap.

Refer to the next topics for the overlap conditions.

[116] Signal overlap circuit II

The first overlap condition occurs at the start. The pilot signals at
the valve 1V2 from the valves 1S3 and 1S2 are opposed. The bista-
ble valve cannot move due to overlap.

Discuss the options for removal of overlap.

[117] Signal overlap circuit III

The second overlap condition occurs in the third step. The valve
2V2 has signals generated by 2S1 and 2S2 opposing each other
and causing a signal overlap condition.

Review the control diagram topic 118.

[118] Control diagram, signal overlap

The first control valve 1V2 has an overlap problem in the first step.
The first of these signals must be out short and therefore valve 1S2
could be an idle return roller lever valve. The second overlap prob-
lem is with valve 2V2 in step 3, when the cylinder 2A1 is fully ad-
vanced. Valve 2S1 could be an idle return roller valve only active in
step 2 for a short duration.

Idle return roller valves are not a recommended solution.

626 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
[119] Idle return roller valve solution

The idle return roller limit switch can be used to remove the signal
overlap points, i.e. replace the roller lever limit switches identified,
with an idle return roller lever valve. Valves 1S2 and 2S1 generated
the signal overlap and therefore these valves should be idle return
roller valves.

Idle return roller valves are not a recommended solution.

[120] Reversing valve solution

An alternative method of shortening the duration of signals is to


remove the air supply to the two signal valves, except at the steps
required. Using the reversing valve 1V2, lines S1 and S2 can be
activated consecutively and the signals are prevented from over-
lapping at the memory valves 1V1 and 2V1.

Emphasize the increased reliability of the circuit.

23.10 Educational Films

23.10.1 Educational Films

No. Title Length


1 Introduction 2:42
2 Fundamentals: Structure of hybrid systems 4:32
3 Fundamentals: Fundamentals of electricity 10:26
4 Sensors and relays Signals 0:48
5 Sensors and relays Sensors 3:24

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 627
6 Sensors and relays Pressure switches 2:41
7 Sensors and relays Relays 3:34
8 Solenoid valves 2:48
9 Solenoid valves: Double-solenoid valves 1:47
10 Solenoid valves: Pilot control 3:58
11 Pilot control: Circuit-diagram conventions 4:14
12 Pilot control: Hard-wired controllers 4:58
13 Pilot control: Programmable Logic Control- 2:25
lers

23.11 Standard Presentations

For several topics useful presentations have been provided within


FluidSIM. The following table lists the titles of the predefined
presentations.

23.11.1 Presentations

Presentation Title
All topics sorted by number
Basics
Supply elements
Actuators
Directional control valves
Shutoff valves
Flow control valves
Pressure control valves
Time delay valve

628 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Sequential circuit and signal overlap circuit
Educational films

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 629
Didactics Material Survey (Hydraulics)

Chapter 24
24. Didactics Material Survey (Hydra ulics)

This chapter provides a comprehensive listing of those parts of the


didactics material in FluidSIM that are not covered by chapter The
Component Library The Component Library. Basically, this mate-
rial consists of the components' behavior illustrations, the anima-
tions, the exercises, and the educational films, which all can be
activated under the Didactics menu. The subsequent sections
are arranged thematically. The icon indicates that an animation
exists for the related topic. The last section gives an overview of the
educational films.

24.1 Applications

[1] Lathe

Machine-tool construction is a typical area of application of hydrau-


lics. With modern CNC machine tools, the tools and workpieces are
clamped by hydraulic means. Feed motions and the spindle drive
can also be hydraulically powered.

This can also serve as an example of hydraulic circuit with two


pressure ranges, for example, 3 MPa (30 bar) for machining
and 9 MPa (90 bar) for clamping.

[2] Press with elevated reservoir

This is an application in which extremely high forces are required.


Due to the suspended cylinder and the tractive load, special
measures are required for the activation of the advance stroke. This
in turn requires specially-designed press drives.

A special feature is the elevated reservoir, which utilizes the


static pressure in the pressure medium.

630 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
[3] Mobile hydraulics: Excavator

On this hydraulic excavator, not only all working movements (linear


drives) but also the propulsion of the vehicle (rotary drive) are
hydraulically powered. The primary drive of the excavator is an
internal-combustion engine.

A model calculation can be used here to demonstrate an ad-


vantage of hydraulics - large forces with relatively small com-
ponents.

24.2 Components of a Hydraulic Plant

[4] Structure of a hydraulic system

This simplified block diagram shows the division of hydraulic sys-


tems into a signal control section and a hydraulic power section.
This signal control section is used to activate the valves in the
power control section.

The material depicted in these electronic slides is concerned in


the main with the hydraulic power section and the three lev-
els of this which are shown.

[5] Hydraulic power section

The diagram of the hydraulic power section is complemented in this


case by a circuit diagram to allow correlation of the various function
groups; the power supply section contains the hydraulic pump and
drive motor and the components for the preparation of the hydrau-
lic fluid. The energy control section consists of the various valves
used to provide control and regulate the flow rate, pressure and

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 631
direction of the hydraulic fluid. This drive section consists of cylin-
ders or hydraulic motors, depending on the application in question.

[6] Block diagram of a control system

In analyzing and planning an actual control task, it can be helpful to


use a differentiated block diagram showing the actual levels to be
found on the machine.

The light arrows show the signal flow, while the solid dark
arrows show the energy flow.

[7] Interaction of components

The animations show the sequences in a basic hydraulic circuit in


simplified form - the actuation and spring return of the final control
element (4/2-way valve), the advance and return of the drive com-
ponent (double acting cylinder) and the opening and closing of the
pressure relief valve.

The representations of the actuator and final control element


are based on the relevant circuit symbols. This can be used as
a preparation for the introduction of circuit symbols.

[8] Action related numbering

First of all the control chain is numbered sequentially according to


the principle. The first actuator is given the supplementary num-
ber.0 and the associated final control element the supplementary
number.1. The remaining elements get even numbers if they influ-
ence the advance stroke and uneven numbers if they influence the
return stroke.

The numbering should always be entered in the circuit diagram


and also on the machine to enable systematic fault-finding.

632 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
[9] Numbering in accordance with DIN ISO 1219-2

The DIN ISO Standard 1219-2 defines the code structure of the
components as a string consisting of the following four parts:
number of the plant, number of the circuit, component designation,
and component number. If the entire system consists of a single
plant only, the plant number may be dropped.

[10] Numbering in accordance with parts list

Another method used in practice is to number all the components


in a hydraulic system consecutively. The numbers then correspond
to the numbers in the parts list.

This method is used particularly with complex controls sys-


tems, for which a control-chain-related numbering system can-
not be used due the overlaps involved.

24.3 Symbols

[11] Circuit symbols for energy transfer (1)

The symbols shown are used in circuit diagrams for energy transfer
and hydraulic-fluid preparation.

In the interests of clarity, the lines in the circuit diagram should


be drawn without cross-overs as far as possible.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 633
[12] Circuit symbols for energy transfer (2)

The direction of the arrows in the circuit symbols for the heater and
cooler correspond to the direction of heat flow.

[13] Circuit symbols for energy conversion

Hydraulic pumps are shown by a circle with a part representation of


a drive shaft. Triangles in the circles show the direction of flow. The
triangles are shown solid, since pressure fluid is used in hydraulics.

If the pressure medium is gaseous, as in the case of pneumat-


ics, the triangles are shown in outline.

[14] Circuit symbols for hydraulic motors

The symbols for hydraulic motors are distinguished from the sym-
bols for hydraulic pumps by the fact that the arrows showing the
direction of flow are the other way round.

[15] Circuit symbols for single acting cylinders

Single acting cylinders have one port, i.e. pressure fluid can be
applied only to the piston side. With these cylinders, the return
stroke is produced either by external force, shown in the symbol by
an opening bearing cap, or by a spring is shown within the symbol
in this latter case.

[16] Circuit symbols for double acting cylinders

Double acting cylinders have two ports to allow pressure fluid to be


applied to both cylinder chambers. The symbol for a differential
cylinder is distinguished from the symbol for a double acting cylin-

634 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
der by the two lines added to the end of the piston rod. The area
ratio is generally 2:1. In the case of cylinders with double- ended
piston rods, the symbol shows that the piston areas are of equal
size (synchronous cylinders).

[17] Circuit symbols for directional control valves (1)

Designations for directional control valves always give firstly the


number of ports and then the number of switching positions. Direc-
tional control valves always have at least two ports and at least two
switching positions. The number of squares shows the number of
possible switching positions of a valve. Arrows within the squares
show the direction of flow. Lines shown how the ports are intercon-
nected in the various switching positions of the valve. The designa-
tions always relate to the normal position of the valve.

[18] Circuit symbols for directional control valves (2)

This illustration shows the circuit symbols for 4/2- and 5/2-way
valves.

There are two general methods for the designation of ports,


using either the letters P, T, R, A, B and L or consecutively using
A, B, C, D etc.; the first method is the preferred one in the rele-
vant standard.

[19] Circuit symbols for directional control valves (3)

The illustration shows the circuit symbols for 4/3-way valves with
various mid-positions.

[20] Circuit symbols for manual operation

The switching position of a directional control valve can be changed


by various actuation methods. The symbol for the valve is accord-

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 635
ingly supplemented by a symbol indicating the actuation methods
shown, such as pushbuttons and pedals, a spring is always neces-
sary for resetting. Resetting can, however, also be achieved by
actuating the valve a second time, for example in the case of valves
with hand levers and detents.

The various actuating methods possible are listed in DIN ISO


1219.

[21] Circuit symbols for mechanical actuation

This illustration shows the symbols for stem or push button, spring
and roller stem.

[22] Circuit symbol for pressure valves

Pressure valves are represented using squares. The flow direction


is indicated by an arrow. The valve ports can be designated as P
(supply port) and T (tank return port) or as A and B. The position of
the arrow within the square indicates whether the valve is normally
open or normally closed. Adjustable pressure valves are indicated
by a diagonal arrow through the spring. Pressure valves are divided
into pressure relief valves and pressure regulators.

[23] Circuit symbols for flow control valves

A distinction is made in flow control valves between types which


are affected by viscosity and those which are unaffected. Flow
control valves unaffected by viscosity are termed orifices. A 2-way
flow control valve consists of restrictors, one adjustable restrictor
which is unaffected by viscosity (orifice) and a regulating restrictor
(pressure compensator). These valves are represented by a rectan-
gle containing the symbol for the adjustable restrictor and an arrow
to represent the pressure compensator. The diagonal arrow
through the rectangle indicates that the valve is adjustable.

636 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
[24] Circuit symbols for non-return valves

The symbol for non-return valves is a ball which is pressed against


a seat. Delockable non-return valves are shown by a square con-
taining the symbol for a non- return valve. The pilot control for
unlocking the non- return valve is indicated by a broken line at the
pilot port. The pilot port is designated by the letter X.

[25] Circuit symbols for measuring devices

The illustration shows the symbols for measuring devices used in


hydraulics.

24.4 Some Physical Fundamentals

[26] Hydrostatic pressure

Hydrostatic pressure is the pressure created above a certain level


within a liquid as a result of the weight of the liquid mass. Hydro-
static pressure is not dependent on the shape of the vessel con-
cerned but only on the height and density of the column of liquid.

Hydrostatic pressure can generally be ignored for the purpose


of studying hydraulics (exception: see topic 2).

[27] Pressure propagation

If a force F acts on an area A of an enclosed liquid, a pressure p is


produced which acts throughout the liquid (Pascals Law).

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 637
Hydrostatic pressure has been ignored here. The term pressure
propagation is also used to mean the pulse velocity in liquids
(approx. 1000 m/s).

[28] Power transmission

If a force F_1 is applied to an area A_1 of a liquid, a pressure p


results. If, as in this case, the pressure acts on a larger surface A_2,
then a larger counter-force F_2 must be maintained. If A_2 is three
times as large as A1, then F_2 will also be three times as large as
F_1.

Hydraulic power transmission is comparable to the mechanical


law of levers.

[29] Displacement transmission (1)

If the input piston of the hydraulic press travels a distance s_1, a


volume of fluid will be displaced. This same volume displaces the
output piston by the distance s_2. If the area of this piston is larger
than that of the input piston, the distance s_2 will be shorter than
s_1.

Hydraulic displacement transmission is comparable to the


mechanical law of levers.

[30] Displacement transmission (2)

See topic 29

[31] Pressure transfer (1)

The fluid pressure p_1 exerts a force F_1 on the surface A_1 which
is transferred via the piston rod to the small piston. The force F_1
thus acts on the surface A_2 and produces the fluid pressure p2.
Since the piston area A_2 is smaller than the piston area A_1, the
pressure p_2 must be larger than the pressure p_1.

638 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
The pressure-transfer (pressure-intensification) effect is put to
practical use in pneumatic/hydraulic pressure intensifiers and
also in purely hydraulic systems when extremely high pres-
sures are required which a pump cannot deliver.

[32] Pressure transfer (2)

A pressure-transfer effect also occurs in conventional double acting


cylinders with single piston rod.

This effect also causes problems in hydraulics. If, for example,


an exhaust flow control is fitted to a differential cylinder for the
advance stroke, a pressure- intensification effect results in the
piston-rod chamber.

[33] Types of flow

A distinction is made between laminar flow and turbulent flow. In


the case of laminar flow, the hydraulic fluid moves through the pipe
in ordered cylindrical layers. If the flow velocity of the hydraulic
fluid rises above a critical speed, the fluid particles at the center of
the pipe break away to the side, and turbulence results.

Turbulent flow should be avoided in hydraulic circuits by ensur-


ing they are adequate sized.

[34] Diesel effect

A pressure drop to the level of vacuum may occur at points of


restriction, causing precipitation of the air dissolved in the oil.
When the pressure rises again, oil bursts into the gas bubbles and
spontaneous ignition of the oil/air mixture may occur.

[35] Cavitation

Motion energy is required for an increase in the flow velocity of the


oil at a restriction. This motion energy is derived from the pressure
energy. If the vacuum which results is smaller than -30 kPa (-0.3

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 639
bar), air dissolved in the oil is precipitated out. When the pressure
rises again due to a reduction in speed, the oil bursts into the gas
bubbles.

Cavitation is a significant factor in hydraulic systems as a cause


of wear in devices and connections.

[36] Cavitation

Local pressure peaks occur during cavitation. This causes the


erosion of small particles from the wall of the pipe immediately
after the reduced cross-section, leading to material fatigue and
often also to fractures. This effect is accompanied by considerable
noise.

[37] Input and output power

Various losses occur at the individual devices within a hydraulic


control chain. These consist essentially of mechanical, electrical
and volumetric losses.

After an installation has been in service for some time, there


will be a change in particular in the volumetric efficiency of the
pump, as the result, for example, of cavitation (see topic 35).

24.5 Components of a Power Unit

[38] Hydraulic power unit

The hydraulic power unit (power supply unit) provides the energy
required for the hydraulic installation. Its most important compo-
nents are the reservoir (tank) , drive (electric motor), hydraulic
pump, pressure relief valve (safety valve), filter and cooler. The

640 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
hydraulic power unit may also act as a carrier for other devices
(gauges, directional control valves).

[39] Hydraulic power unit: Reservoir

The hydraulic reservoir contains the hydraulic fluid required the


operate the installation. Within the reservoir, air, water and solid
matter are separated out of the hydraulic fluid.

The size of the reservoir will depend on the practical applica-


tion involved; for stationary systems, the volume of fluid deliv-
ered by the pump in 3 to 5 minutes can be taken as a guide. In
mobile hydraulic systems, on the other hand, the reservoir con-
tains only the maximum quantity of hydraulic fluid required.

[40] Externally toothed gear pump

The increase in volume which results when a tooth moves out of


mesh produces a vacuum in the suction area. The hydraulic fluid is
conveyed into the pressure area. The hydraulic fluid is then forced
out of the tooth gaps by the meshing of the teeth and displaced
into the above supply line.

[41] Internally toothed gear pump

The inner gear is driven by a motor. The teeth of the inner wheel
drive the outer gear wheel. The rotary motion creates a vacuum in
the gaps between the teeth, causing hydraulic fluid to be sucked in.
On the other side, the teeth engage once more and oil is displaced
from the tooth chambers.

The design can deliver pressures of up to approx. 17.5 MPa


(175 bar). Hydraulic motors represent the reverse of the func-
tion principle.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 641
[42] Circuit diagram: Return flow filter

An oil filter situated in the return line to the tank has the advantage
that the filter is thus easy to maintain. A disadvantage, however, is
that contamination is removed from the hydraulic fluid only after it
has passed through the hydraulic components.

This configuration is often used.

[43] Circuit diagram : Pump inlet filter

With this configuration, the pump is protected from contamination.


The filter is, on the other hand, less easily accessible.

If these filters have a too fine mesh, suction problems and


cavitation effects may occur. Additional coarse filters upstream
of the pump are recommended.

[44] Circuit diagram: Pressure line filter

Pressure filters can be installed selectively upstream of valves


which are sensitive to contamination; this also enables smaller
mesh sizes to be used.

A pressure-resistant housing is required, which makes this


configuration more expensive.

[45] Circuit diagram: Contamination indicator

It is important that the effectiveness of a filter can be checked by a


contamination indicator. The contamination of a filter is measured
by the pressure drop; as the contamination increases, the pressure
upstream of the filter increases. The pressure acts on a spring-
loaded piston. As the pressure increases, the piston is pushed
against a spring.

642 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
There are a number of different display methods. Either the
piston movement is directly visible or it is converted into an
electrical or visual indication by electrical contacts.

[46] Water cooler

With this design of cooler, hydraulic fluid is fed through tubes over
which coolant (water) flows. The heat which is discharged can be
re-used.

The operating temperature in hydraulic installations should not


exceed 50 - 60{C}, since this would cause an unacceptable re-
duction in viscosity, leading to premature aging of the fluid. In
comparison with air cooling, operating costs a higher due to
the required coolant and the susceptibility to corrosion. Tem-
perature difference of up to approx. 35{C} can be handled.

[47] Air cooler

Hydraulic fluid from the return line flows through a coiled pipe
which is cooled by a fan.

The advantages here are simplicity of installation and low


operating costs. The noise of the fan may be a nuisance (see
also topic 46).

[48] Heating element

Heaters are often required to ensure that the optimum operating


temperature is reached quickly. Heating elements or flow preheat-
ers are used for heating and pre-heating hydraulic fluid.

If the viscosity is to high, the resulting increase in friction and


cavitation leads to greater wear.

[49] Circuit diagram: Hydraulic power unit

The illustration shows the detailed circuit symbol for a hydraulic


power unit.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 643
Since this is an combination unit, a dot/dash line is placed
around the symbols representing the individual units.

24.6 Fundamentals of Valves

[50] Actuating force

With some types of poppet valves, the actuating force, which is


dependent on pressure and area, may be very high. In order to
avoid this, pressure compensation may be provided at the valves.

[51] Poppet principle

Valves are based either on the poppet principle or slide principle. In


poppet valves, a ball, a cone or a disc is pressed by a spring against
the seat of a passage. The high pressure per unit area which is
created, means that valves of this kind provide a very efficient seal.
The illustration shows a cone used as a sealing element.

[52] Slide principle

This illustration shows the principle of a longitudinal slide valve. In


order to allow the piston to move, it has a certain clearance and
floats in hydraulic fluids. Ring grooves ensure an even film of oil
and thus pressure equilibrium. The piston can thus be moved with
minimal frictional losses.

This type of valve cannot provide a perfect seal, which means


that there is always a certain oil leakage.

644 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
[53] Poppet valves

In poppet valves, a ball, cone or occasionally a disk is pressed


against a seat area to act as a sealing element. Valves of this type
provide a very efficient seal.

[54] Piston overlap

The switching characteristics of a valve are governed by, among


other things, its piston overlap. A distinction is made between
positive, negative and zero overlap. In the case of positive overlap,
the port in question is completely covered by the piston, while with
negative overlap it is less than completely covered. In the case of
zero overlap, the distances between the control edges of the piston
and of the port are exactly the same.

The individual control edges of the pilot piston can have differ-
ent overlaps.

[55] Negative switching overlap

In the case of negative overlap, flow from A to T is not quite closed


when the inlet P is opened. This means that the pressure at port A
rises slowly and the piston starts gently.

In manufacturers' data sheets, overlap positions are shown


within dotted lines between the switching positions, or the
overlap positions are shown in color or with a patterned back-
ground.

[56] Positive switching overlap

In the case of positive overlap, the left-hand piston does not open
the passage from P to A until the tank has been completely isolated
by the other piston. Pressure is immediately fed to the load device
(cylinder or hydraulic motor) with the result that this starts abrupt-
ly.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 645
[57] Control edges

The control edges of the pistons are often either sharp, chamfered
or notched. The profiling of the control edges means that the throt-
tling action of the flow when switching is gradual rather than ab-
rupt.

See also the example in topic 144.

[58] Vertical interconnection system

Vertical interconnection systems (modular hydraulics) mean that


less space is required and that no piping is needed between the
components. The circuit symbols directly marked on the compo-
nents give greater clarity in the installation.

24.7 Pressure Valves

[59] Pressure relief valve (1)

In this design incorporating a poppet valve, a seal is pressed


against the inlet port P by a pressure spring when the valve is in its
normal position.

In this situation, for example, an unloaded piston rod is execut-


ing an advance stroke and the entire pump delivery is flowing
to the cylinder.

[60] Pressure relief valve (2)

As soon as the force exerted by the inlet pressure at A exceeds the


opposing spring force, the valve begins to open.

646 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
In this situation, for example, the piston rod is fully advanced;
the entire pump delivery is flowing at the preset system pres-
sure to the tank.

[61] PRV used to limit system pressure

This illustration shows a pressure relief valve within a basic hydrau-


lic circuit (used to control a double acting cylinder).

The resistances at the outlet (tank line, filter) must be added to


the force of the spring in the pressure relief valve. See also the
animation Interaction of components (topic 7).

[62] Circuit diagram: PRV used to limit system pressure

This illustration shows the same circuit as the previous illustration,


but with the cut-away view of the PRV replaced by the appropriate
circuit symbol.

[63] Circuit without brake valve

One application of pressure relief valves is as brake valves; these


prevent pressure peaks which may otherwise occur as the result of
mass moments of inertia when a directional control valve is sud-
denly closed. The animation shows an (incorrect) circuit in schemat-
ic form in which the working line on the exhaust side has fractured
due to the absence of a brake valve.

The next animation (topic 64) shows the correct circuit.

[64] Circuit diagram: Brake valve

This illustration shows the correct circuit for the problem in topic
63. This circuit incorporates not only a brake valve on the piston-
rod side but also a non-return valve on the inlet side via which oil
can be taken in from a reservoir during the vacuum phase following
the closure of the directional control valve.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 647
The following animation shows the events which occur in the
two working lines.

[65] Circuit with brake valve

First the animation shows in schematic form the behavior of the


PRV during the braking phase, then it shows the behavior of the
non-return valve (NRV) in the supply line.


The necessity of the brake valve can be demonstrated by topic 63.

[66] Circuit diagram: PRV as back-pressure valve

Back-pressure valves counteract mass moments of inertia with


tractive loads. The illustration shows a circuit with a back-pressure
valve on the piston-rod side. On the return stroke, the PRV is by-
passed by an NRV.

The PRV must be pressure-compensated and the tank port


must be capable of carrying a pressure load.

[67] PRV, internally controlled, cushioned

Pressure relief valves often incorporate cushioning pistons or flow


control valves. The cushioning device shown provides fast opening
and slow closing of the valve. This prevents damage caused by
pressure shocks (smooth valve operation).

Pressure shock arise, for example, when the pump delivers oil
in an almost unpressurized condition and the supply port of the
load device is abruptly closed by a directional control valve.

[68] PRV, externally controlled (1)

This pressure relief valve controls the flow in accordance with an


external pressure setting. This pressure acts against an adjustable

648 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
spring force. The passage from the supply port P to the tank port T
remains closed as long as no load acts on the pilot piston.

[69] PRV, externally controlled (2)

Pressure can be fed to the pilot piston via the pilot port X. As soon
as the pressure force at the pilot piston exceeds the preset spring
force, the pilot piston is displaced, allowing free flow.

[70] Sequence valve

The example shows a circuit with a pressure relief valve used as a


pressure sequence valve. The pressure at the pilot piston of the
PRV rises via the pressure regulator. The PRV opens and the high-
pressure pump delivers directly to the tank. As soon as the 2/2-way
valve opens, the pressure drops. The pressure relief valve closes
and the high pressure pump is connected to the system.

[71] Circuit diagram: Sequence valve

This illustration shows the same circuit as the previous illustration,


but with the cut-away view of the sequence valve replaced by the
appropriate circuit symbol.

[72] Pressure relief valve

Actual photograph of a pressure relief valve.

[73] 2-way pressure regulator (1)

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 649
This valve is normally open. The outlet pressure (A) acts via a pilot
line on the left-hand surface of the pilot piston against an adjusta-
ble spring force.

Pressure regulators reduce the inlet pressure to an adjustable


outlet pressure. It is appropriate to use these in hydraulic in-
stallations only if different pressures are required.

[74] 2-way pressure regulator (2)

When the pressure rises at outlet A, the force at the left-hand


surface of the pilot piston becomes greater, the piston is displaced
to the right and the throttle gap becomes narrower. This causes a
pressure drop.

In the case of slide valves, it is also possible to design the


control edges in such way that the opening gap increases only
slowly. This gives greater control precision.

[75] 2-way pressure regulator (3)

When the preset maximum pressure is reached, the throttle point


closes completely; the pressure set on the pressure relief valve is
produced at the inlet P.

[76] 2-way pressure regulator (4)

In the circuit illustrated, the piston rod of the cylinder is executing


an advance stroke. The pressure at the outlet A of the pressure
regulator is less than the system pressure at P and constant.

[77] 2-way pressure regulator (5)

The piston rod of the cylinder is now in its forward end position.
The pressure at outlet A thus continues to rise and the throttle
point closes completely.

650 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
[78] Circuit diagram: 2-way pressure regulator

The illustration shows the same circuit as the previous illustration,


but with the 2-way pressure regulator in the form of a circuit sym-
bol.

[79] Circuit diagram: 2-way pressure regulator

It is appropriate to use PRVs only when different pressures are


required in an installation. The mode of operation of pressure
regulator will thus be explained here by taking an example with two
control circuits. The first control circuit acts via a flow control valve
on a hydraulic motor which drives a roller. This roller is used to
stick together multi-layered printed circuit boards. The second
control circuit acts on a hydraulic cylinder which draws the roller
towards the boards at an adjustable reduced pressure.

This example can be used as a preliminary stage to the intro-


duction of the 3-way PR. If the 2-way PR is closed due to the
fact that the preset maximum pressure has been reached,
thickening of the material of the workpieces would cause an in-
crease in the pressure on the outlet side of the PR to a higher
value than desired. (See also the animation for topic 84.)

[80] 3-way pressure regulator (1)

The 3-way pressure regulator can be regarded as a combination of


a 2-way PR and a pressure relief valve (PRV). The PR is in its normal
position here; only a low pressure has built up at the outlet A.

[81] 3-way pressure regulator (2)

When the pressure at A rises the result of external conditions, this


pressure acts via a pilot line on the left-hand piston surface of the
pilot piston against an adjustable spring force. Every pressure

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 651
increase causes the throttle gap to become narrower, resulting in a
pressure drop.

[82] 3-way pressure regulator (3)

When the maximum preset pressure is reached, the throttle point


closes completely. The pressure set on the system-pressure limiter
is produced at the inlet P.

[83] 3-way pressure regulator (4)

If the pressure rises above the preset value as the result of an


external load at outlet A, the valve opens to allow flow from A to the
tank port T (pressure-limiter function).

3-way pressure regulators are available with both positive and


negative piston overlap. If a 3-way pressure regulator is creat-
ed by combining a 2-way pressure regulator and a pressure re-
lief valve, the overlap is adjustable.

[84] 3-way pressure regulator

The animation shows both the pressure-regulator and pressure-


limiter function of a 3-way pressure regulator through the example
of a roller which exerts a constant pressure on moving material of
variable thickness.

The final control element which is normally interposed has


been omitted here in the interests of clarity.

[85] 3-way pressure regulator (5)

A 3-way PR is shown here in a functional representation, incorpo-


rated into a model circuit diagram. The piston rod of the cylinder is
subject to external force and the pressure regulator provides a
pressure-limiter function.

652 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
[86] 3-way pressure regulator (6)

The illustration shows the same circuit as the previous illustration,


but with the functional representation of the 3-way pressure regu-
lator replaced by a detailed circuit symbol.

3-way pressure regulators are available with both positive and


negative piston overlap. If a 3-way pressure regulator is creat-
ed by combining a 2-way pressure regulator and a pressure re-
lief valve, the overlap is adjustable.

[87] Circuit diagram: 3-way pressure regulator

The illustration shows the same circuit as the previous illustration,


but with the standard circuit symbol for a 3-way pressure regulator.

24.8 Way Valves

[88] 2/2-way valve (1)

The 2/2-way valve has a working port A, a supply port P and a


leakage-oil port L. In the case of the valve shown here, of slide
design, flow from P to A is closed in the normal position.

A relief line leading to the leakage-oil port is provided to pre-


vent a build-up of pressure in the spring and piston chambers.

[89] 2/2-way valve (2)

The 2/2-way valve is actuated and the passage from P to A is open.

2/2-way valves are also available which are normally open


from P to A.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 653
[90] 2/2-way valve as by-pass valve

This example shows a 2/2-way valve used as a by-pass valve; when


the 2/2-way valve is actuated, the flow control valve 0V2 is by-
passed, causing the piston rod of the cylinder to advance at maxi-
mum speed.

[91] Circuit diagram: 2/2-way valve as by-pass valve

The illustration shows the same circuit as the previous illustration,


but with the functional representation of the 2/2-way valve re-
placed by a circuit symbol.

[92] Circuit diagram: 2/2-way valve as final control element

In its initial position, the cylinder is advanced. If the 2/2- way valve
0V1 is actuated, the entire volumetric flow passes to the tank and
piston rod of the cylinder is reset by the external load m. If 0V1 is
not actuated, the system pressure set on the pressure limiter 0V2
builds up and the piston rod advances.

In the initial position, the pump operates against the preset


system pressure, which has an unfavorable effect on the power
balance of the circuit shown.

[93] 2/2-way valve as final control element

The animations show the actuation and release of the 2/2-way


valve, which causes the piston rod of the cylinder to advance and
retract.

654 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
[94] Circuit diagram for pressure-less pump recirculation

The part circuit diagram shows a 2/2-way valve used as a by-pass


valve to achieve pressure-less pump recirculation; if the valve is
actuated, the pump no longer needs to operate against the preset
system pressure.

One application of this circuit is with 4/3-way valves which are


closed in their mid-position in cases where, with the installa-
tion operational, it is desired to switch to pump recirculation
(see also topic 116).

[95] Circuit diagram: Pressure stage circuit

The part circuit diagram shows a 2/2-way valve used as a selector


switch for one of two preset system pressures (pressure levels);
if the 2/2-way valve is actuated, flow is enabled to a second sys-
tem-pressure limiter.

[96] 3/2-way valve (poppet principle) (1)

The 3/2-way valve has working port A, a supply port P and a tank
port T. Volumetric flow can be routed from the supply port to the
working port or from the working port to the tank port. The third
port in each case is closed. In the normal position shown, P is
closed and flow released from A to T.

See also topic 101 (slide principle).

[97] 3/2-way valve (poppet principle) (2)

The 3/2-way valve is actuated; flow is released from P to A, the


outlet T is closed.

3/2-way valves which are normally open from P to A and T


closed are also available.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 655
[98] 3/2-way valve as final control element

The circuit shows the 3/2-way valve in a functional representation


as a final control element of a single acting cylinder.

The non-return valve protects the pump in cases where the


3/2-way valve is actuated and the piston rod is subject to an
external load.

[99] Circuit diagram: 3/2-way valve as final control element

The illustration shows the same circuit as the previous illustration,


but with the circuit symbol for the 3/2-way valve.

[100] 3/2-way valve

The animations show the actuation and release of the manual


pushbutton for a 3/2-way valve, which causes the piston rod of the
cylinder to advance and retract.

[101] 3/2-way valve (slide principle) (1)

The 3/2-way valve has a working port A, a supply port P and a tank
port T. The volumetric flow can be routed from the supply port to
the working port, or from the working port to the tank port. The
third port in each case is closed. In the normal position shown, P is
closed and flow is released from A to T.

See also the 3/2-way valve designed on the poppet principle


(Topic 96).

656 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
[102] 3/2-way valve (slide principle) (2)

The 3/2-way valve is actuated; flow is released from P to A, and the


outlet T is closed.

3/2-way valves which are normally closed from P to A and T are


also available.

[103] 3/2-way valves as diverter

In addition to their application as final control elements, 3/2-way


valves can also be used as diverters. In this case, port T is connect-
ed to a further device, to which a switch-over can then be made.
The part circuit diagrams show the facility to switch between the
flow control valves with different settings and between heating and
cooling.

The circuit symbol is drawn reversed to simplify the representa-


tion of the circuit diagram.

[104] 4/2-way valve, two pistons (1)

The 4/2-way valve has two working ports A and B, a supply port P
and a tank port T. The supply port is always connected to one of the
working ports, while the second working port is routed to the tank.
In the normal position, there is flow from P to B and from A to T.

In contrast to valves with three pistons, 4/2-way valves with


two pistons do not require a leakage-oil port (see topic 106).

[105] 4/2-way valve, two pistons (2)

The 4/2-way valve is actuated, and there is flow from P to A and


from B to T.

4/2-way valves are also available which are normally open


from P to A and from B to T.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 657
[106] 4/2-way valve, three pistons (1)

This 4/2-way valve has two working ports A and B, a supply port P
and a tank port T. The supply port is always connected to one of the
working ports, while the second working port is routed to the tank.
In the neutral position, there is flow from P to B and from A to T.

4/2-way valves with three pistons require a leakage-oil port,


since hydraulic fluid would otherwise be trapped within the
valve.

[107] 4/2-way valve, three pistons (2)

The 4/2-way valve is actuated, and there is flow from P to A and


from B to T.

[108] 4/2-way valve, three pistons (3)

The circuit shows the 4/2-way valve in functional representation as


a final control element of a double acting cylinder.

The non-return valve protects the pump in cases where the


piston rod of the cylinder is subject to an external load.

[109] Circuit diagram: 4/2-way valve

The illustration shows the same circuit as the previous illustration,


but with the 4/2-way valve as a circuit symbol.

[110] 4/3-way valve with pump bypass (1)

From the logic point of view, 4/3-way valves are 4/2- way valves
with an additional mid-position. There are various versions of this
mid-position (in the mid-position in the example shown, the supply

658 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
port P is directly connected to the tank T, see next illustration). In
the switching position shown, there is flow from P to B and from A
to T.

4/3-way valves are easy to construct as slide valves and of


complex design as poppet valves.

[111] 4/3-way valve with pump bypass (2)

The 4/3-way valve is in its mid-position; there is flow from P to T,


while A and B are closed. Since the output from the pump flows to
the tank, this switching position is called pump bypass or also
pump recirculation.

In the case of pump bypass, the pump needs to operate only


against the resistance of the valve, which has a favorable effect
on the power balance.

[112] 4/3-way valve with pump bypass (3)

The valve is in its left-hand switching position; there is flow from P


to A and from B to T.

[113] 4/3-way valve with pump bypass (4)

The circuit shows the 4/3-way valve in functional representation as


a final control element of a double acting cylinder. The valve is in its
mid-position; the pump delivery flows via the by-pass line within
the pilot piston to the tank.

The non-return valve protects the pump in cases where the


piston rod of the cylinder is subject to an external load.

[114] Circuit diagram: 4/3-way valve with pump bypass

The illustration shows the same circuit as the previous illustration,


but with the 4/3-way valve as a circuit symbol.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 659
[115] 4/3-way valve with pump bypass

The animations show the switching of the 4/3-way valve into the
three switching positions and the corresponding cylinder move-
ments. During the advance stroke, movement can be halted by
switching to the mid- position.

As appropriate to the application in question, a circuit of this


kind must be equipped with a brake valve to prevent damage
to the installation when the valve is switched to the mid-
position (see also topic 64).

[116] 4/3-way valve with closed mid-position (1)

From the logic point of view, 4/3-way valves are 4/2- way valves
with an additional mid-position. There are various versions of this
mid-position (in the mid-position in the example shown, all ports
are closed in the mid- position, see next illustration). In the switch-
ing position shown, there is flow from P to B and from A to T.

[117] 4/3-way valve with closed mid-position (2)

The 4/3-way valve is in its mid-position; all ports apart from the
leakage-oil port are closed.

In this mid-position, the pump is operating against the system


pressure set on the pressure relief valve.

[118] 4/3-way valve with closed mid-position (3)

The valve is in its left-hand switching position; there is flow from P


to A and from B to T.

660 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
[119] 4/3-way valve with closed mid-position (4)

The circuit shows the 4/3-way valve in functional representation as


a final control element of a double acting cylinder. The valve is in its
mid-position; the pump is operating against the system pressure
set on the PRV.

If, with an operational installation, it is desired to switch to


pump recirculation, this can be achieved by using an additional
2/2-way valve as a changeover valve (see part circuit-diagram
in topic 94).

[120] Circuit diagram: 4/3-way valve with closed mid-position

The illustration shows the same circuit as the previous illustration,


but with the 4/3-way valve as a circuit symbol.

[121] 4/3-way valve: overlap positions (1)

The illustration shows the left-hand overlap position of a 4/3-way


valve with positive overlap in the mid-position (closed mid-
position). This overlap position is a mixture of positive and negative
overlap; P is connected to A, B and T are closed.

With 4/3-way valves, the types of overlap positions is generally


specified in the data sheet.

[122] 4/3-way valve: overlap positions (2)

The illustration shows the right-hand overlap position of a 4/3-


way valve with positive overlap in the mid- position (closed mid-
position). This overlap position, too, is a mixture of positive and
negative overlap; P is connected to B, A and T are closed.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 661
[123] Way valve

Actual photograph of a directional control valve with lever actua-


tion.

[124] 4/3-way module

This 4/3-way module with hand-lever actuation is used in vertical


interconnection systems (modular hydraulics).

See also the illustration in topic 58.

24.9 Shutoff Valves

[125] Non-return valve (1)

Non-return valves block flow in one direction and allow free flow in
the other. In the direction of flow shown, the sealing element is
pressed against a seat by a spring and the hydraulic fluid.

These valves are also available in designs without springs.


Since there must be no leaks in the closed position, these
valves are generally of poppet design.

[126] Non-return valve (2)

In the direction of flow shown, the valve is opened by the hydraulic


fluid, which lifts the sealing element from the seat.

662 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
[127] Circuit diagram: Pump protection

In this circuit, the non-return valve is used to protect the pump.


This prevents a load pressure from driving the pump in reverse
when the electric motor is switched off. Pressure peaks do not
affect the pump but are discharged via the pressure relief valve.

[128] Graetz block (1)

In the Graetz rectifier circuit (Graetz block), four non- return valves
are combined to form a function unit. The circuit diagram shows
how this operates in conjunction with a flow control valve; flow
passes through this valve from left to right during both the advance
and return strokes of the cylinder. The situation during the advance
stroke is shown.

During the advance stroke shown here, flow control is carried


out on the inlet side.

[129] Graetz block (2)

The cylinder is on its return stroke. The rectifier circuit means that
flow once again passes through the flow control valve from left to
right.

During the return stroke shown here, flow control is carried out
on the outlet side.

[130] Graetz block

The animation shows the actuation and spring return of a 4/2-way


valve and the flow through the Graetz block during the advance and
return strokes.

Similar rectifier circuits are also used in conjunction with line


filters or brake valves.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 663
[131] Delockable non-return valve (1)

In the cases of delockable non-return valves, flow in the closed


direction can be released by means of an additional pilot port (X).
The illustration shows the valve in its normal position; flow from B
to A is closed.

[132] Delockable non-return valve (2)

The released piston is pressurized via pilot port X. This lifts the
sealing element from its seat and releases flow from B to A.

In order to release the valve reliably, the effective area of the


pilot piston must always be greater than the effective area of
the sealing element. Piloted non-return valves are also availa-
ble with lockable non-return function.

[133] Delockable non-return valve (3)

The model circuit diagram shows how a load can be positioned by


holding a cylinder using a suitable delockable non-return valve. The
valve becomes active in the return stroke whereby the restriction
on the piston side is released by actuation of the 3/2-way valve.

See also the animation 135 on this topic.

[134] Circuit diagram: Delockable non-return valve

The illustration shows the same circuit as the previous illustration,


but with the piloted non-return valve as a circuit symbol.

664 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
[135] Delockable non-return valve

The 4/2-way valve is actuated, the hydraulic fluid passes through


the non-return valve against the force of the return spring and the
piston rod advances. When the 4/2-way valve is reset, the outlet on
the piston side is closed by the non-return valve, and the cylinder
remains advanced. The 3/2-way valve is now actuated, the pilot
piston is reversed and the outlet flow released; the piston rod
begins to retract. During the return stroke, the 3/2-way valve is
brought temporarily into its normal position. This causes the outlet
to be closed again, and the piston rod and load remain in their
current position. When the 3/2-way valve is actuated again, the
piston rod travels to its retracted end position.

[136] Delockable double non-return valve (1)

Delockable double non-return valves allow a load to be positioned


reliably with the cylinder at a standstill, even if eternal leaks exist
around the cylinder piston. When, as in the case, neither of the
inlets A_1 or A_2 is pressurized, B_1 and B_2 are closed.

[137] Delockable double non-return valve (2)

When A_1 is pressurized, the left-hand sealing element is lifted


from its seat, enabling flow to B_1. At the same time, the pilot
piston is displaced to the right, releasing flow from B_2 to A_2.

The opposite is true when inlet A_2 is pressurized.

[138] Delockable double non-return valve (3)

The model circuit diagram shows a delockable double non-return


valve used in conjunction with a 4/3-way valve to allow the vertical
positioning of a load. In the mid-position of the final control ele-
ment shown, ports A and B are connected to the tank. This means

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 665
that the inlets A_1 and A_2 of the double non-return valve are
pressure-less and both cylinder supply lines are closed.

[139] Circuit diagram: Delockable double non-return valve

The illustration shows the same circuit as the previous illustration,


but with the delockable double non-return valve as a circuit sym-
bol.

24.10 Flow Valves

[140] Needle restrictor

Throttle and orifice valves are used to achieve a certain pressure


drop. This is done by creating a specific flow resistance. The needle
flow control valve shown generates considerable friction due to its
long narrowing. This means that the action of the flow control valve
is difficult to adjust due to the fact that a small adjustment produc-
es a large change in cross-section.

One advantage is the simple and inexpensive design. Needle


flow control valves can be used if the above- mentioned nega-
tive properties can be ignored for the purposes of a given con-
trol task.

[141] Gap restrictor with helix

Its short narrowing means that the action of this gap flow control
valve is virtually independent of viscosity. The helix provides pre-
cise adjustability, since adjustment from fully open to fully closed
requires a 360 turn. The helix is, however, very costly to produce.

666 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
[142] Circuit diagram: Flow division using restrictor

Throttle and orifice valves control the volumetric flow rate in con-
junction with a pressure relief valve. The PRV opens when the
resistance of the flow control valve becomes greater than that of
the opening pressure set on the PRV. This produces a division of
flow.

The volumetric flow to the load device varies, i.e. the action of
flow control valves is load-dependent.

[143] Throttle valve

Actual photograph of a flow control valve.

[144] One-way flow control valve (1)

The one-way flow control valve is a combination of an orifice or


throttle valve and a non-return valve. In the closed direction shown
of the non-return valve, the volumetric flow passes via the variable
throttle gap, which creates a considerable resistance.

Speed reduction can be achieved by using a one-way flow


control valve in conjunction with a pressure relief valve or a
variable-delivery pump. The pressure rises upstream of the
flow control valve until the PRV opens and routes part of the
flow to the tank.

[145] One-way flow control valve (2)

In the reverse direction, from B to A, flow is unrestricted, since the


ball in the one-way flow control valve allows free flow (non-return
function).

One-way flow control valves are available with a fixed restrictor


and with variable flow control.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 667
[146] 2-way flow control valve (1)

Flow control valves have the task of providing constant volumetric


flow independently of pressure changes at the inlet or outlet of the
valve. This is achieved firstly by means of an adjustable restrictor
which is set to the desired volumetric flow. In order to keep the
pressure drop across the throttle point constant, a second regulat-
ing restrictor (pressure compensator) is also required. The illustra-
tion shows the valve in its normal position.

2-way flow control valves always operate in conjunction with a


pressure relief valve. The part of the flow which is not required
is discharged via the PRV.

[147] 2-way flow control valve (2)

When fluid flows through the valve, the pressure drop across the
adjustable restrictor is kept constant by the pressure compensator,
which varies the resistance at the upper throttle point in accord-
ance with the load at the inlet or outlet.

See also the animation 150 for this topic.

[148] 2-way flow control valve (3)

In the case of this flow control valve, the pressure difference is kept
constant by a adjustable restrictor, i.e. between p_1 and p_2. If the
pressure p_3 rises as the result of an external load, the overall
resistance of the valve is reduced by opening the regulating restric-
tor.

[149] Circuit diagram: 2-way flow control valve

The model circuit diagram shows the arrangement of a 2-way flow


control valve in the piston-side supply line in order to achieve a
constant feed speed even under varying load. A non-return valve is

668 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
fitted in the by-pass to allow the flow control valve to be by-passed
on the return stroke.

[150] 2-way flow control valve

The advancing piston rod encounters a load half-way through its


stroke. The flow control valve nonetheless ensures that the ad-
vance speed remains constant. From 0 to 2 seconds (shown at
bottom right) the piston rod is unloaded and the pressure condi-
tions remain constant. When the piston rod encounters the load,
the pressure p_3 rises at the outlet of the flow control valve. (In
order to allow the rapid control operations to be shown more clear-
ly, the time scale now changes to 1/100ths of a second.) The flow
control valve briefly raises the pressure p_2 downstream of the
adjustable restrictor. Following this, the regulating restrictor moves
to the left, and p_2 falls back to its original value, i.e. the pressure
difference between p_1 and p_2 remains constant. The regulating
operation shown is repeated a number of times, as the result of
which p_3 increases to 2.5 MPa (25 bar) in several steps and the
regulating restrictor opens more and more. (At the point at which
2.5 MPa (25 bar) is reached, the time scale changes back to 0.1
seconds.) The piston rod now travels under load just as fast as
previously without load.

24.11 Hydraulic Cylinders and Motors

[151] Single acting cylinder

In the case of a single acting cylinder, only the piston side is pres-
surized with hydraulic fluid. The cylinder can thus carry out work
only in one direction. The fluid which flows into the piston chamber
causes a pressure to build up the surface of the piston. The piston
travels into its forward end position. The return stroke is effected
by a spring, the dead weight of the piston rod or an external load.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 669
[152] Plunger cylinder

In the case of plunger cylinders, the piston and rod form a single
component. Due to the design of the cylinder, the return stroke can
only be effected by external forces. The cylinders can therefore
generally be installed only vertically.

[153] Double acting cylinder

In the case of double acting cylinders, both piston surfaces can be


pressurized. A working movement can thus be performed in both
directions.

With double acting cylinders with a single-sided piston rod,


different forces and speeds are obtained on the advance and
return strokes due to the difference in area between the piston
surface and annular piston surface.

[154] Double acting cylinder with end position cushioning

Cylinder with end position cushioning are used to brake high stroke
speeds smoothly and prevent hard impacts at the end of the stroke.
Shortly before the end position is reached, the cross- section for
the outflow of fluid is reduced by the built-in cushioning pistons
and then finally closed. The hydraulic fluid is then forced to escape
through a flow control valve.

[155] End position cushioning (1)

The piston is a short distance before its end position; the hydraulic
fluid on the piston-rod side must escape via the adjustable flow
control valve above the piston rod

670 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
This type of end position cushioning is used for stroke speed
between 6 m/min and 20 m/min. At higher speed, additional
cushioning or braking devices must be used.

[156] End position cushioning (2)

The piston rod is on its return stroke; in this flow direction, the non-
return valve below the piston rod is opened, thus by-passing the
flow control valve. The piston rod retracts at maximum speed.

[157] End position cushioning

The illustration shows first the advance of the piston rod from a
mid-position to the forward end position, with cushioning at the
end of the advance movement. The non-return valve is open during
the return stroke.

In addition the animation shows the opening of the pressure


limiter after a certain pressure has been built up on the outlet
side by the cushioning piston.

[158] Double acting cylinder

Actual photograph of a double acting cylinder.

[159] Automatic bleed valve

When the cylinder is retracted, the piston of the bleed valve is


closed. It is lifted as the piston rod advances. Air can then escape
via the bleed hole until the hydraulic fluid reaches the piston and
pushes it upwards. In the forward end position, the piston is
pushed fully upwards by the hydraulic fluid and thus provides an
external seal.

Bleed valves should be fitted at the highest point in a piping


system, since this is where any trapped air will collect.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 671
24.12 Gauges

[160] Piston pressure gauge

Pressure gauges operate on the principle that pressure acting on a


given area will produce a given force. In the case of piston pressure
gauges, the pressure acts on a piston against the force of a spring.
The pressure value is now shown on a scale either by the piston
itself or by a pointer driven magnetically by the piston.

[161] Bourdon-tube pressure gauge

Most pressure gauges operate on the principle of a Bourdon tube.


When hydraulic fluid flows into the tube, an identical pressure is
produced throughout. Due to the difference in area between the
outer and inner curved surfaces, the tube is bent. This movement is
transferred to a pointer.

This type of gauge is not protected against overload. A cush-


ioning restrictor must be installed in the inlet connection pre-
vent pressure surges from damaging the tube.

[162] Flow meter

The flow of oil to be measured passes through a movable orifice.


The orifice consists of a fixed cone and a hollow piston mounted on
a spring. The piston is pressed against the spring in proportion to
the flow rate concerned. The measuring error of this type of flow
meter is approx. 4%. Measuring turbines, oval disk meters or
toothed-wheel gauges are used when higher accuracy is required.

672 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
24.13 Exercises

[163] Exercise: Horizontal grinding machine (pump delivery)

The slide on a horizontal grinding machine is hydraulically actuat-


ed. A machine operator determines that the reciprocating move-
ment of the machine is no longer reaching the desired speed. A
possible cause of this is reduced pump delivery. To investigate this,
it is necessary to plot a characteristic curve for the pump and com-
pare this with the values achieved during initial commissioning. As
an additional exercise, the circuit diagram and parts list for the
necessary test assembly should be prepared.

In order to draw the characteristic curve for the pump, the volu-
metric flow of hydraulic fluid delivered by the pump (Q) is plotted
against the operating pressure achieved (p). The manufacturers
characteristic curve exhibits a slight downward gradient, since the
new pump manifests increasing internal leakage losses as neces-
sary to provide internal lubrication. The newly-plotted curve shows
a clear deviation; the leakage oil losses have become greater at
higher operating pressures, the volumetric efficiency has become
worse. The main reason for this is pump wear. Regarding the circuit
diagram for the test assembly: The adjustable flow control valve
1V3 is adjusted in such a way that the pressure gauge 1Z1 shows
the desired system pressure. The pressure relief valve 1V2 is used
to limit the system pressure, while valve 1V1 acts as a safety valve
for the pump.

The measured values taken as the basis for this exercise do not
allow for the characteristic curve of the electric motor. The mo-
tor characteristic thus forms part of the calculated error.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 673
[164] Exercise: Bending machine (directly-controlled pressure
relief valve)

A bending machine is used to bend steel plates. The bending tools


are driven by hydraulic cylinders. It is now desired to use the bend-
ing machine for considerably thicker steel plates than before. This
requires a hydraulic system pressure of 45 bar against the previous
30 bar. According to the manufacturers data, the pump used is
suitable for the higher operating pressure. Testing reveals, howev-
er, that the bending process is now much too slow. In this case,
leakage losses in the piping or directional control valve are ruled
out as the cause of the problem. A directly-controlled pressure
relief valve (PRV) is installed as a safety valve. Measurements of
the volumetric flow (Q) as a function of pressure (p) are available
for this valve. A characteristic curve can then be used to determine
whether the loss of speed in the bending process is due to the PRV.

The volumetric flow which is discharged to the tank when the PRV
opens is entered on the horizontal axis. The characteristic curve
shows that the opening point of the PRV is 44 bar, although it is set
to 50 bar. This means that part of the pump delivery is diverted at
pressures greater than 44 bar. Pressures of more than 44 bar are
achieved during the bending process. Since, however, the flow is
divided from 44 bar onwards, the volumetric flow to the cylinder is
reduced from this point and the bending process slows down.
Measure to be taken: The PRTV can be set to 60 bar if the overall
installation has been designed for this higher pressure. Flow diver-
sion will then take place from a pressure of 54 bar onwards.

An alternative solution would be to use a valve with a different


response pressure.

[165] Exercise: Roller conveyor (flow resistance)

Steel blocks are transported on a roller conveyor. A hydraulic


transfer station makes it possible to transfer blocks from one track

674 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
to another. A pressure of at least 30 bar is required for the transfer
of blocks by means of hydraulic cylinders. Every component
through which the hydraulic fluid flows represents a resistance and
causes a constant pressure loss. The question is, what pressure is
to be set at the pressure relief valve.

The total resistance is the sum of all the individual resistances.


The resistance must be determined separately for the advance and
return strokes. The overall balances do not include data for the
pressure losses at the 4/2-way valve. These can be determined
from the flow characteristic for the 4/2-way valve, based on a
volumetric flow of 8 l/min. In the calculation, allowance must be
made for the resistance of the directional control valve on the inlet
and outlet sides respectively. Allowance must also be made for the
pressure intensification factor of 2:1 in the case of the differential
cylinder. This enables values to be calculated as shown in the
solution figure. In the case of the advance stroke, 6 bar hysteresis
for the PRV (see exercise 164) must be added to the calculated 42.5
bar in order to ensure that the opening pressure is higher than the
required operating pressure. The value finally chosen is 50 bar in
order to make allowance for unknown variables such as pipe el-
bows and the static friction in the cylinder.

In order to keep pressure losses in large installations to a


minimum, it is advisable to select valves on the basis of their
flow characteristics. It is better to select a valve which is one
size too large than to accept large pressure losses. This fur-
thermore reduces wear resulting from cavitation in the valves.

[166] Exercise: Embossing press (activation of a single acting


cylinder)

Additional hydraulic components are to be added to an embossing


press to eject the finished workpieces. A single acting cylinder (1A)
is to be fitted for this purpose. A proposed solution in the form of a
circuit diagram with a 2/2-way valve is to be examined to see if it is
suitable for this control problem. Following this, a circuit diagram
with a 3/2-way valve as final control element is to be developed

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 675
and a parts list prepared. A comparison is to be made of the behav-
ior of these two circuits during the advance and return strokes.

When a 2/2-way valve is used to activate a single acting cylinder,


the final control element must be reversed and the hydraulic power
unit switched off in order to retract the piston rod. The load acting
on the piston rod must be larger than the resistance of the direc-
tional control valve. This solution cannot be used due to the pres-
ence of the second control chain (embossing cylinder). If a 3/2-way
valve is used, a direct switch-over can be made from the advance
stroke to the return stroke without switching off the hydraulic
power unit. Halting at overlap positions, on the other hand (which
are not required here), would be possible only by switching off the
hydraulic power unit.

The non-return valve fitted in each case protects the pump


against oil back-pressure. This is necessary in case the hydrau-
lic power unit is switched off with the cylinder advanced and
under load.

[167] Exercise: Ladle (activation of a double acting cylinder)

Liquid aluminum is transferred from a holding furnace into a chan-


nel leading to a die-casting machine. A ladle is required for this. A
double acting cylinder is used to enable the ladle to carry out the
appropriate movements. A circuit diagram is provided for the acti-
vation of the cylinder with a 4/2-way valve as final control element.
This must be examined to see if it is suitable for the control task
concerned. The ladle must not be allowed to dip into the furnace
when the valve is not actuated. A circuit diagram with a back-
pressure valve must be developed to cater for the case in which the
ladle is very heavy.

The requirements of the exercise are met by the first circuit dia-
gram only if the ladle represents a light load. If the ladle is very
heavy, the advance speed could rise to an unacceptably high level
during the advance stroke of the piston rod (ladle moving towards
furnace), and the ladle could as a result plunge too quickly into the

676 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
molten metal. This can be prevented by installing a back- pressure
valve in the B line between the valve and cylinder (tractive load).

If, as is required in this exercise, the power component must


positively assume a defined end position when the installation
is at rest, valves with spring return must be used, as in this
case. Here, a 4/2-way valve with spring return has been used,
since this ensures that the cylinder remains in the desired posi-
tion if the hydraulic power unit is switched on unexpectedly.
The required cylinder diameter and the return speed of the pis-
ton rod can also be calculated as additional optional tasks in
the exercise: see the model calculations in the textbook.

[168] Exercise: Paint drying oven (4/3-way valve)

Workpieces are fed continuously through a paint drying oven on a


conveyor belt. In order to minimize the heat loss through the door,
this should be opened only as much as required by the height of
the workpieces. The hydraulic control system should be designed
so that the door can be held reliably in position for a long period of
time without slipping down. Firstly, a 4/3-way valve with suitable
mid-position functions should be selected as a final control ele-
ment. Secondly, a delockable non-return valve should be provided
in the circuit diagram to act as a hydraulic safety device to prevent
slippage of the door under load (i.e. its own weight) over a long
period of time as the result of leakage losses in the directional
control valve. The question is, which type of 4/3-way valve has a
suitable mid-position function?

A 4/3-way valve with an all ports closed mid-position will solve


the problem only if a poppet valve is used. If a slide valve would be
used, the oven door would slip down slowly as the result of internal
leakage losses.

The second solution would be to fit a delockable non- return


valve in the supply line to the piston rod side of the cylinder
downstream of the directional control valve. In order to ensure
that the non-return valve closes immediately when the door

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 677
stops, both the outlets A and B of the directional control valve
to the tank must be de-pressurized (A, B and T connected, P
closed).

[169] Exercise: Clamping device (closing speed)

Workpieces are clamped by a hydraulic cylinder. The closing speed


must be reduced in order to prevent damage to the workpieces. The
opening speed must, however, be maintained. The question here is
how to incorporate the necessary one-way flow control valve in the
circuit. Possible solutions must be examined to see what thermal
side- effects occur and to determine the pressure load placed on
the components concerned.

The advance stroke can as a general principle be made slower by


using either inlet or outlet flow control. Either solution can be used
in this control; in comparison with outlet flow control, inlet flow
control has the advantage that no pressure intensification will take
place. The oil heated at the throttle point will, however, then pass
through the power component. The resulting expansion of material
is not, however, of significance for this simple vice. If the solution
with outlet flow control is selected, it should be borne in mind that
pressure intensification will take place in accordance with the area
ratio of the differential cylinder of 2:1. The pressure relief valve will
respond, i.e. flow division will occur, only when a pressure has built
up on the piston-rod side which is approximately twice as high as
the system pressure set on the PRV. The cylinder, flow control valve
and connectors used must therefore be suitable for this intensified
pressure.

Precision drives for machine tools are a good example of cases


in which it is essential to make allowance for expansion of the
material of power components due to the passage through
these of heated oil.

678 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
[170] Exercise: Hydraulic crane (speed reduction)

Press tools of varying weights are inserted into a press by means of


a hydraulic crane. A double acting cylinder raises and lowers the
load. During the commissioning of the hydraulic crane, it has be-
come apparent that the advance speed of the piston rod is too
high. The solutions have been proposed to reduce this speed; a
circuit with exhaust flow control and a circuit with a back-pressure
valve. A suitable solution must be selected and reasons stated for
this choice. Since the second solution is not capable of operating in
this form, this must be rectified by correcting the circuit diagram.

If the solution with exhaust flow control is selected, it must be


borne in mind that the cylinder, flow control valve and connectors
must be suitable for this intensified pressure. The solution chosen
is the circuit with the back-pressure valve; in this case, the load is
clamped hydraulically and a pressure-intensification effect does not
occur, since the pressure can be adjustable by means of the pres-
sure relief valve as appropriate to the load. A non-return valve must
be installed to provide a by-pass on the return stroke.

Inlet flow control cannot be used to control a tractive load; the


load forces oil out of the piston-rod chamber faster than oil can
flow into the piston chamber. Vacuum is created and air will
escape.

[171] Exercise: Feed control for a lathe (speed control)

The feed movement of a lathe has previously been carried out


manually. In future, this is to be performed automatically by a
hydraulic control system. The feed movement must be adjustable
and remain constant even with changing tool loads. Since a simple
throttle valve is not able to provide a constant feed speed under
changing load, a 2-way flow control valve must be used. On the
basis of a circuit diagram with data for the no- load situation, val-
ues for pressures, pressure differences and feed speed under load

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 679
must be added. The circuit diagram must be modified to ensure
that the flow control valve is not operative on the return stroke.
Finally, the relationship must be investigated between Q of the PRV
and the feed speed and between p_2 and the volumetric flow to the
load device.

In order to prevent the flow control valve from acting as a re-


sistance on the return stroke, a non-return valve is installed parallel
to this as a by-pass. The pressure at the PRV remains constant
despite the effect of the load. The outlet flow from this is therefore
a constant 7 l/min. A constant volumetric flow Q at the PRV in turn
means a constant volumetric flow to the load device and thus
constant feed speed. Regarding the last question: No matter
whether operation is with or without a load, the pressure drop p_2
at the adjustable throttle remains constant. A constant pressure
drop means a constant volumetric flow.

Regarding the necessity for the non-return valve in the by-pass:


When flow passes through 2-way flow control valves in the re-
verse direction, they act either as flow control valves if the reg-
ulating restrictor is fully open or non-return valves if the regu-
lating restrictor is closed.

[172] Exercise: Planing machine (by-pass circuit)

The sliding bed of a parallel planing machine is actuated with the


aid of a hydraulic control system. The power section of this hydrau-
lic control system consists of a double acting differential cylinder.
The area ratio of the full piston surface of this cylinder to the annu-
lar piston surface is 2:1. Since the piston-rod chamber is only half
the volume of the piston chamber, the return stroke is twice as fast
as the advance stroke. Machining has previously been carried out
only during the advance stroke. In future, working movements are
to be carried out in both directions. To make this possible, the
hydraulic control system must be modified so that forward and
return strokes are at the same speed. The speed should now also
be adjustable. The connecting lines should be added to the given
circuit diagram. The mode of operation of the circuit in the three

680 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
switching positions should be described and the various piston
speeds and forces compared.

In order to achieve the same speed on the advance and return


strokes, a differential circuit (by-pass circuit) can be used with
differential cylinders with an area ratio of 2:1. Picture 116.2 The
second picture shows the principle of a by-pass circuit with a 3/2-
way valve. In the case of the parallel planing machine, the neces-
sary differential circuit can be achieved by using the mid-position of
a 4/3-way valve (A, B and P connected, T closed). In this switching
position (advance stroke), the piston speed and force are twice as
high as in the right-hand switching position (return stroke). In the
left-hand switching position, on the other hand, the advance stroke
is half as fast and the force twice as great as in the other two
switching positions. The speed for the advance and return strokes
can be adjusted by means of a flow control valve fitted upstream.

It should also be noted that only half the force is available on


the advance stroke at the mid-position. In the case of a tractive
load, the by-pass position has the advantage that the piston is
hydraulically clamped. Differential circuits are used not only as
synchronization circuits but also as rapid-traverse circuits
when, for example, different speeds are required in the same
direction with constant pump delivery. If it is desired to calcu-
late forces and piston speeds using concrete values, the model
values given in the TP 501 textbook can be used for this pur-
pose.

[173] Exercise: Drilling machine (pressure regulator)

The drill feed and clamping device of a drilling machine are hydrau-
lically actuated. The hydraulic control system contains two cylin-
ders, a clamping cylinder 1A and a feed cylinder 2A. The clamping
pressure at cylinder 1A must be adjustable, since different
workpiece clamping forces are required. A pressure regulator is
used for this. The return stroke of the clamping cylinder must be at
maximum speed. The drilling feed must be adjustable for various
feed speeds, which must however remain constant under varying

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 681
load. It should also be noted that the drive spindle fitted to the
piston rod of the drilling cylinder acts as a tractive load. The return
stroke of the drilling cylinder should also be at maximum speed. A
circuit should be drafted with the above-mentioned characteristics.

Pressure regulators can as general principle be used to reduce the


general system pressure in a part of a hydraulic installation. If we
consider the two control chains for the drilling machine without
pressure regulation, we can observe the following undesirable
effects: When 1V1 is actuated, the workpiece is first clamped at full
system pressure. If 2V1 is now actuated, the system pressure will
drop to the operating pressure of the drilling cylinder. The same
applies to the pressure at the clamping cylinder. If the circuit is
expanded to include the pressure regulator 1V3, this enables the
clamping pressure to be adjusted. The system pressure upstream
of the PRV will, however, continue to fall during the advance stroke
of 2A. In order to maintain the preset clamping pressure at outlet A
of the PRV reliably, the pressure at inlet P must be higher than this.
This can be achieved by fitting the additional flow control valve 0V2
upstream of the final control element 2V1. Maximum return-stroke
speed is achieved for the clamping cylinder by means of 1V2, which
is used to by-pass 1V3. The flow control valve 2V3 means that the
advance-stroke speed of the drilling cylinder is independent of load
and adjustable. Due to the tractive load of the attached spindle,
however, an additional PRV must be fitted as a back-pressure
valve. The non-return valves 2V2 and 2V5 provide a by-pass during
the return stroke and allow maximum speed to be achieved during
this.

A parts list can be specified to help in the drafting of this cir-


cuit.

682 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
24.14 Educational Films

24.14.1 Educational Films

No. Title Length


1 Introduction 3:20
2 Fundamentals: Pressure fluids 2:02
3 Fundamentals: Pressure and Flow Rate 2:41
4 Fundamentals: Transmission of Force and 1:35
Displacement
5 Fundamentals: Pressure Transmission 0:53
6 Fundamentals: Types of Flow 2:10
7 Basic Design of Hydraulic Systems 1:13
8 The Hydraulic Power Unit 3:26
9 Hydraulic Drives 6:58
10 Valves 3:12
11 Valves: Directional Control Valves 10:39
12 Valves: Non-Return Valves 1:59
13 Valves: Pressure Control Valves 4:24
14 Valves: Flow Control Valves 4:23
15 Representation of Hydraulic Systems in 2:58
Circuit Diagrams

24.15 Standard Presentations

For several topics useful presentations have been provided within


FluidSIM. The following table lists the titles of the predefined
presentations.

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 683
24.15.1 Presentations

Presentation Title
All topics sorted by number
Applications
Components of a hydraulic system
Graphic and circuit symbols
Fundamental physical principles
Components of the power supply section
Valves in general
Pressure valves
Directional control valves
Non-return valves
Flow control valves
Hydraulic cylinders and motors
Measuring devices
Exercises

684 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Index

Index

3
3/2-way valve
ball seat _____________________________________ 601, 602
disc seat_____________________________________ 602, 603
pneumatically operated ________________________ 603, 604
roller operated____________________________________ 604
4
4/2-way valve
disc seat_________________________________________ 605
roller operated____________________________________ 605
4/3-way valve
turning disc principle_______________________________ 605
5
5/2-way valve
longitudinal slide principle __________________________ 606
suspended disc seat _______________________________ 607
5/3-way valve
pneumatically operated ____________________________ 607
A
air drying
absorption _______________________________________ 592
adsorption _______________________________________ 592
low temperature __________________________________ 591
air lubricator _____________________________________ 592, 593
air motor ____________________________________________ 600
air service unit _______________________________________ 590
C
circuit diagram
bistable valve ________________________________ 607, 608
direct control _____________________________________ 609
indirect control ___________________________________ 609
pressure sequence valve ___________________________ 621
quick exhaust valve ________________________________ 617
sequential control _________________________________ 625
shuttle valve _________________________________ 614, 615
signal overlap ________________________________ 626, 627

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 685
time delay valve___________________________________ 623
two pressure valve ____________________________ 612, 613
component
animation animation
component ______________________________________ 572
description didactics
component description ____________________________ 565
sectional view component
usage in circuit didactics
sectional view __________________________________ 567
compressed air filter filter ______________________________ 591
compressed air supply
axial flow compressor axial flow compressor ____________ 594
delivery _________________________________________ 593
distribution ______________________________________ 594
piston compressor piston compressor _________________ 594
cylinder
control cylinder
double acting ____________________________________ 597
single acting _____________________________________ 596
double acting _________________________________ 597, 598
mounting arrangements ____________________________ 598
seals____________________________________________ 598
single acting _____________________________________ 596
tandem double acting ______________________________ 599
D
Delay Switches ___________________________________ 477, 492
diagram symbol
designation of connections __________________________ 600
directional valve __________________________________ 600
flow control valve _________________________________ 618
linear actuator ____________________________________ 595
method of actuation _______________________________ 601
non-return valve diagram symbol
check valve ______________________________________ 611
numbering system _________________________________ 589
pressure control valve ______________________________ 620
rotary actuator____________________________________ 595
supply component_________________________________ 590
Dialog window
diagram properties ________________________________ 339
drawing areas ____________________________________ 342
Functional diagram ________________________________ 338
line options ______________________________________ 348

686 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
signal logic_______________________________________ 349
signaling elements ________________________________ 345
text options ______________________________________ 340
didactics
actuators ________________________________________ 595
applications ______________________________________ 630
basic pneumatics _________________________________ 588
cylinder didactics
motor __________________________________________ 669
directional control valves ___________________________ 600
educational film educational film
overview ____________________________________ 627, 683
exercises ________________________________________ 673
flow control valves ________________________________ 618
flow valves _______________________________________ 666
gauge ___________________________________________ 672
hydraulic plant____________________________________ 631
physical fundamentals _____________________________ 637
power unit _______________________________________ 640
presentation presentation
play ____________________________________________ 579
presentations
overview ________________________________________ 683
presentations presentation
overview ________________________________________ 628
pressure control valves _____________________________ 620
pressure valves ___________________________________ 646
sequential circuit didactics
signal overlap circuit ______________________________ 625
shutoff valves ________________________________ 611, 662
supply elements __________________________________ 590
symbols _________________________________________ 633
time delay valve___________________________________ 622
tutorial tutorial ___________________________________ 573
valves ___________________________________________ 644
way valves _______________________________________ 653

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 687
Digital Basic Functions _________________________________ 548
Digital Components ___________________________________ 546
Digital Special Functions _______________________________ 550
Digitale Constants ____________________________________ 546
DIN standard ________________________________________ 565
distance-step diagram _________________________________ 625
Druckschalter ________________________________________ 482
E
electrical components
american standard ________________________________ 491
ladder diagram style _______________________________ 491
Electrical Components _________________________________ 468
electronic components _________________________________ 497
exercise
bending machine __________________________________ 674
clamping device___________________________________ 678
drilling machine ___________________________________ 682
drying oven ______________________________________ 678
embossing press __________________________________ 676
feed control ______________________________________ 680
grinding machine__________________________________ 673
hydraulic crane ___________________________________ 679
ladle ____________________________________________ 677
planing machine __________________________________ 681
roller conveyor____________________________________ 675
F
function illustration
general sectional view______________________________ 575
G
GRAFCET Elements ____________________________________ 556
L
ladder diagram _______________________________________ 491
Limit Switches ___________________________________ 479, 493
M
measuring devices ____________________________________ 408
measuring instruments ________________________________ 463
menu
context sensitive context sensitive ____________________ 564

688 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM
Miscellaneous _______________________________________ 559
N
non return valve ______________________________________ 612
Numbering __________________________________________ 588
O
one-way flow control valve _________________________ 618, 619
P
Pneumatic Components ________________________________ 410
presentation
creation _________________________________________ 582
edit _____________________________________________ 582
pressure
absolute pressure
atmospheric _____________________________________ 595
pressure control valve _________________________________ 593
pressure switches ____________________________________ 393
Pressure Switches ____________________________________ 495
Proximity Switches ____________________________________ 484
Q
quick exhaust valve _______________________________ 616, 617
S
semi-rotary actuator___________________________________ 599
sequence valve _______________________________________ 620
Service Components __________________________________ 352
shuttle valve _________________________________________ 614
signal flow __________________________________________ 588
signal flow component _________________________________ 588
supply air throttling exhaust air throttling _________________ 619
supply elements ______________________________________ 410
switch
pressure operated _________________________________ 443

Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM 689
T
Throttle valve ________________________________________ 619
time delay valve delay valve ________________________ 622, 623
two pressure valve ____________________________________ 612
V
valves
configurable _________________________________ 360, 417
directional _______________________________________ 364
directional valves _________________________________ 421
flow control ______________________________________ 393
flow control valves ________________________________ 437
groups __________________________________________ 451
pressure _________________________________________ 381
shutoff __________________________________________ 378
shutoff valves ____________________________________ 437
way valves ___________________________________ 360, 417

690 Festo Didactic GmbH & Co. KG Art Systems GmbH FluidSIM

You might also like