Fan Dry Coil Unit
Fan Dry Coil Unit
Fan Dry Coil Unit
H i g h Q u a l i t y T e c h n i q u e
Features
Hygrostat
Thermo -
Suitable for maintenance of super clean grade.
Modification and expansion according to the change of the manufacturing line is easily done.
Wide area is not required for the air handling machine room and installation time is short.
Layout for super clean grade can be freely done.
Installation and operation cost is relatively low.
Heat Recovery
System
Comparison between the Fan Dry Coil Unit and existing method
Dry Coil + FFU System (existing method) Fan Dry Coil Unit + FFU System
Handling Unit
Slim Type Air
Direct Expansion Type
Air Handling Unit
All the circulation air from the clean room is processed with Part of the circulation air from the clean room is processed with
sensible heat load at the Dry Coil, and then supplied into the room sensible heat load at the Dry Coil and then mixed with the air that is
through the FFU(Fan Filter Unit) by-passed and supplied into the room through the FFU (Fan Filter Unit).
Structural materials are the Off Gas alternation that has low generation of organic gas
Constructability
Improved constructability due to equipment in compact size
Standard specification
ACE R & A
155
www.aceind.co.kr
ACE Air Conditioning System
ACE Air Conditioning System
Fan Dry Coil Unit Built-Up Unit Fan Ceiling Type Air Direct Expansion Type Slim Type Air Heat Recovery Thermo - Air Handling Unit
Handling Unit Air Handling Unit Handling Unit System Hygrostat
Technical Data
9.807 x 104 0.9807 1 735.56 9.807 x 105 0.9678 14.22 2.05 x 103
133.32 1.333 x 10-3 1.3596 x 10-3 1 1.3332 x 103 1.3157 x 10-3 1.933 x 10-2 2.784
0.10 1 x 10-6 1.0197 x 10-6 7.50 x 10-4 1 0.987 x 10-6 1.450 x 10-5 2.089 x 10-3
1.01325 x 105 1.01325 1.0332 760.0 1.0133 x 106 1 14.6925 2116
6.895 x 103 6.895 x 10-2 7.031 x 10-2 51.73 6.895 x 104 6.806 x 10-2 1 144.0
47.88 4.788 x 10-4 4.88 x 10-4 0.359 478.80 4.726 x 10-4 0.6944 x 10-2 1
SI unit Metric engineering unit Ft-lb system engineering unit Metric engineering unit Ft-lb system
SI unit
Refrigerating capacity
engineering unit
m/s Km/h m/h ft/s ft/h mile/h W usRT JRT kcal/h Btu/h
Velocity
1 3.6 3.6 x 103 3.281 1.181 x 104 2.237 1 0.2843 x 10-3 0.2590 x 10-3 0.8598 3.412
0.278 1 1 x 103 0.9114 3.281 x 103 0.6214 3.517 x 103 1 0.9108 3024 1.20 x 104
0.278 x 10-3 1 x 10-3 1 9.114 x 10-4 3.281 6.214 x 10-4 3.862 x 103 1.098 1 3320 1.317 x 104
0.3048 1.097 1.097 x 103 1 3.6 x 103 0.6818 1.163 3.307 x 10-4 3.012 x 10-4 1 3.968
8.47 x 10-5 3.048 x 10-4 0.3048 2.780 x 10-4 1 1.894 x 10-4 2.931 0.833 x 10-4 0.759 x 10-4 0.2520 1
0.4470 1.609 1.609 x 103 1.467 5.28 x 103 1 usRT = American refrigeration performance ton, JRT = Japanese refrigeration performance ton
Ft-lb system
SI unit Metric engineering unit
(caloric value energy)
0.2778 1 0.2390 6.639 x 10-4 0.1605 1.338 x 10-2 9.80665 1 2.34 x 10-3 3.7037 x 10-6 2.724 x 10-3 9.293 x 10-3
4.187 x 103 426.9 1 1.581 x 10-3 1.163 3.968
1.163 4.187 1 2.778 x 10-3 0.672 5.60 x 10-2
418.70 1.506 x 103 360 1 241.9 20.16
6
2.6478 x 10 2.7 x 105
632.54 1 735.5 2.51 x 103
1.731 6.232 1.488 4.134 x 10-3 1 8.333 x 10-2 3.6 x 103 367.10 0.860 1.3596 x 10-3 1 3.412
20.77 74.8 17.86 4.96 x 10-2 12 1 1.0551 x 103 107.58 0.252 0.398 x 10-3 0.2931 1
1J = 1N mm