Fılmtec
Fılmtec
Fılmtec
Figure 1
COMPONENT
This component is Tested and
Certified by NSF International
against NSF/ANSI Standard 58
for material requirements only.
Page 1 of 2 ™® Trademark of The Dow Chemical Company ("Dow") or an affiliated company of Dow Form No. 609-50165-0613
Dow FILMTEC™ Membranes
Residential Reverse Osmosis Elements
Influence of temperature and pressure on permeate flow
Figure 2: Figure 3:
Impact of pressure on permeate flow Impact of temperature on permeate flow
(constant temperature, recovery) (constant pressure, recover)
Important • It is recommended that systems using these elements rinse the elements for 24 hours,
information prior to first use, to meet NSF/ANSI 58 Standard.
• The first full tank of permeate must be discarded. Do not use this initial permeate for
drinking water or food preparation.
• Keep elements moist at all times after initial wetting.
• To prevent biological growth during prolonged system shutdowns, it is recommended
that membrane elements be immersed in a preservative solution. Rinse out the
preservative before use.
• The membrane shows some resistance to short-term attack by chlorine (hypochlorite).
Continuous exposure, however, may damage the membrane and should be avoided.
• DOW FILMTEC™ Home Drinking Water Reverse Osmosis Elements may be covered
under the DOW FILMTEC™ Reverse Osmosis and Nanofiltration Element Three-Year
Prorated Limited Warranty, 609- 35010-1006 extended to OEMs. Such Limited Warranty
is non- transferable. Contact a Dow representative for more information.
If operating limits and guidelines given in this Product Information Bulletin are not strictly
followed, the Limited Warranty will be null and void. The OEM is fully responsible for the
effects of incompatible chemicals and lubricants on elements. Use of any such chemicals or
lubricants will void the Limited Warranty.
For more information, call the Dow Water Notice: The use of this product in and of itself does not necessarily guarantee the removal of cysts and pathogens from
& Process Solutions business: water. Effective cyst and pathogen reduction is dependent on the complete system design and on the operation and
North America: 1-800-447-4369 maintenance of the system.
Latin America: (+55) 11-5188-9222 Notice: No freedom from infringement of any patent owned by Dow or others is to be inferred. Because use conditions and
Europe: +800-3-694-6367
applicable laws may differ from one location to another and may change with time, Customer is responsible for determining
Italy: +800-783-825
whether products and the information in this document are appropriate for Customer’s use and for ensuring that Customer’s
South Africa: +0800 99 5078
workplace and disposal practices are in compliance with applicable laws and other governmental enactments. The product
Pacific: +8007776 7776
shown in this literature may not be available for sale and/or available in all geographies where Dow is represented. The claims
China: +400 889-0789
made may not have been approved for use in all countries. Dow assumes no obligation or liability for the information in this
http://www.dowwaterandprocess.com
document. References to “Dow” or the “Company” mean the Dow legal entity selling the products to Customer unless otherwise
expressly noted. NO WARRANTIES ARE GIVEN; ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE ARE EXPRESSLY EXCLUDED.
Page 2 of 2 ™® Trademark of The Dow Chemical Company ("Dow") or an affiliated company of Dow Form No. 609-50165-0613