Piston Pump Metaris
Piston Pump Metaris
Piston Pump Metaris
Features
Axial piston pump MA10VO in swashplate
design is used in open loop circuits.
Flow is proportional to drive speed and
displacement. By adjusting the position of
the swashplate it is possible to smoothly
vary the output flow of the pump.
– Operating pressure 4000PSI (280 bar) – Axial and radial loading of drive shaft
possible
– Good suction characteristics
– Wide range of controls
– Low noise level
– Through drive option for multi-circuit system
– High power/weight ratio
– SAE & ISO mounting flanges available
2
VARIABLE DISPLACEMENT PUMP MA10VO/VSO, SERIES 31
Technical Data
1. Input Operating Pressure Range
Absolute pressure at port S (A)
Pabs min .................. 11.6 PSI or (0.8 Bar)
Pabs max ................. 435 PSI or (30 Bar)
4. Direction of Flow
(“S” inlet port to “B” pressure port)
5. Table of values (theoretical values, without considering ηmh and ηv; values rounded)
Size 18 28 45 71 100 140
Displacement Vgmax cm 3
18 28 45 71 100 140
Max. Speed at Vgmax nomax rpm 3000 3000 2600 2200 2000 1800
Max. flow at nomax Qomax L/min 59.4 84 117 156 200 252
Max. power ∆p = 4000 psi
at nomax Pomax kW 27.7 39 55 73 93 118
(∆p = 280 bar)
Hydraulic Formula
6. Determination of Size Vg = geometric displacement cu.in. or [cm3]
Imperial Metric per rev.
Vg ● n ● ηv Vg ● n ● η v
Flow Q= gpm L/min ∆p = differential pressure PSI or (Bar)
231 1000
n = speed [rpm]
Vg ● ∆p Vg ● ∆p
Torque T= lb-ft Nm ηv = volumetric efficiency
24 ● ● ηmh 20 ● ● ηmh
ηmh = mechanical-hydraulic efficiency
Q ● ∆p Q ● ∆p ηt = total efficiency (ηt = ηv ● ηmh)
Power P= HP kW
1714 ● ηt 600 ● ηt
Q = Flow (gpm) or (L/min.)
3
VARIABLE DISPLACEMENT PUMP MA10VO/VSO, SERIES 31
Performance Information
Flow Q.
Flow Q.
Power @ Q max.
Power @ Q min.
Flow Q.
Power @ Q max.
Power @ Q min.
4
VARIABLE DISPLACEMENT PUMP MA10VO/VSO, SERIES 31
Flow Q.
Power @ Q max.
Power @ Q min.
Flow Q.
Power @ Q max.
Power @ Q min.
5
VARIABLE DISPLACEMENT PUMP MA10VO/VSO, SERIES 31
Size 140
_________
n = 1800 rpm
Total efficiency:
Imperial Metric
Q●P Q●P
ηt =
PQ max ● 1714 PQ max ● 600
Volumetric efficiency:
Q
ηv =
Qtheor.
6
VARIABLE DISPLACEMENT PUMP MA10VO/VSO, SERIES 31
Ordering Code
MA10V 0 71 DR 31 R P S
Modes of operation
Pump, open circuit O
Size
Series
Series 31
Direction of rotation
clockwise R
Viewed on drive shaft
counter-clockwise L
Seals
FPM (fluorocarbon) V
SAE-splined shaft, reinforced (higher thru drive torques) 3/4” 7/8” 1” 1 1/4” * * R
SAE-splined shaft, smaller size (not for pumps with thru drive) 5/8” * 7/8” * 1 1/4” * U
parallel with key DIN 6885 18mm 22mm 25mm 32mm 40mm 45mm P
7
VARIABLE DISPLACEMENT PUMP MA10VO/VSO, SERIES 31
Ordering Code
C 62 N00
Service ports
= available
Multiple Pumps
1. If a second Metaris hydraulic pump is to be factory-mounted, then both ordering codes are to be
specified, combined with a “+”. Ordering code 1st pump + Ordering code 2nd pump. Ordering
example: MA10VO71DR/31R-PSC62K02 + MA10VO28DR/31R-PSC62N00
8
VARIABLE DISPLACEMENT PUMP MA10VO/VSO, SERIES 31
Fluid
1. Hydraulic Fluid
The MA10V open loop pump in the standard design should be used with a good quality, petroleum
based anti-wear hydraulic fluid.
At operating temperature
Optimum viscosity (opt) __80...170 SUS (16 / 36 mm2/s)
3. Temperature Range
Filtration
In order to ensure reliable operation of the axial piston unit, the operating fluid must be maintained
to a cleanliness class of 18/14 to ISO4406 or NAS 1638 class 9. As a guide the fluid cleanliness level
may be achieved using a 10 micron filter.
Installation Information
The pump housing must be filled with clean hydraulic fluid prior to pump start up and remain full.
The concentricity between the prime mover drive shaft and the pump shaft 0.05mm.
.05mm
9
VARIABLE DISPLACEMENT PUMP MA10VO/VSO, SERIES 31
The pump housing must be filled with fluid both when commissioning and in
operation. In order to achieve low noise levels, all connecting lines (inlet, case
drain) should be isolated from the tank by flexible lines.
2. Horizontal Installation
- The pumps must be install so (L) or (L1) the case drain is at the top of the
pump
- If the minimum fluid level is below the ports of the pump, pipe the ports L
or L1 & S below the minimum oil level.
- Avoid mounting above the tank whenever possible in order to maintain a
low noise level.
- The permissible inlet height (h) is a result of the overall pressure loss, “A”
may not be greater then 32 inches (800 mm).
10
VARIABLE DISPLACEMENT PUMP MA10VO/VSO, SERIES 31
DR Pressure Control
The pressure control serves to maintain a
constant pressure in the hydraulic system,
within the control range of the pump. The
pump therefore supplies only the amount
of hydraulic fluid required by the actuators.
Pressure may be smoothly set at the control
valve.
Ports
B Pressure Port
S Suction port
L, L1 Case drain ports (L1 sealed)
Response time
t t t
Dynamic response curve sa(ms) sa (ms) sa (ms)
The operating curves values taken under the Size
following conditions 725 psi / 50 bar 3200 psi / 220 bar 4000 psi / 280 bar
28 60 30 20
Operating Conditions; n = 1500 rpm 45 80 40 20
Oil temperature 120 F / 50C 71 100 50 25
Pressure cut-off 5100 psi / 350bar 100 125 90 30
140 130 110 30
Load values were taken by closing the
pressure line with a load valve .
Control Data
Hysteresis and repetition accuracy p ………………. Max. 3 bar
Max. Pressure Increase
Size 18 28 45 71 100 140
ΔP BAR 4 4 6 8 10 12
Pilot oil consumption …………………..max. approx. 3 L/min
11
VARIABLE DISPLACEMENT PUMP MA10VO/VSO, SERIES 31
Unit dimensions DR
Service ports at rear; Models 61N00 and 11N00
Size 18 to 140
counter clockwise
Unit dimensions DR
Service ports at side; Models 62N00 and 12N00
Size 18 to 140
counter clockwise
12
VARIABLE DISPLACEMENT PUMP MA10VO/VSO, SERIES 31
Static charateristic
(at n1=1500 rpm; oil temp. =125˚F / 51˚C
Ports
B Pressure Port
S Suction port
L, L1 Case drain ports (L1 sealed)
X Pilot pressure port
DRG 140
Control Data
Hysteresis and repetittion accuracy p ………Max. 3 bar
13
VARIABLE DISPLACEMENT PUMP MA10VO/VSO, SERIES 31
Ports
B Pressure Port
S Suction port
L, L1 Case drain ports (L1 sealed)
X Pilot pressure port
14
VARIABLE DISPLACEMENT PUMP MA10VO/VSO, SERIES 31
Flow Control/Differential
Pressure p:
Adjustable between 10 and 22 bar (higher values
on request). Standard setting: 14 bar. If a different
setting is required, please state in clear text.
Control Data
For pressure control technical data see DR Pressure control
Max. flow deviation (hysteresis and increase) measured at drive speed n = 1450 rpm
15
VARIABLE DISPLACEMENT PUMP MA10VO/VSO, SERIES 31
counter clockwise
L
L1
L counter clockwise
L1
16
VARIABLE DISPLACEMENT PUMP MA10VO/VSO, SERIES 31
Ports
B Pressure Port
S Suction port
L, L1 Case drain ports (L1 sealed)
X Pilot pressure port
The power characteristic is factory-set, so please enter details in clear text, e.g. 20 kW at 1450 rpm.
There are four spring arrangements used for the power valve set-up refer to the chart below.
Control data
For pressure control technical data see DR Pressure control.
For flow control technical data see DFR control.
Start of control …………………………… from 80 bar
Pilot oil consumption …………………….. max. approx. 5.5 L/min
17
VARIABLE DISPLACEMENT PUMP MA10VO/VSO, SERIES 31
Size 28 to 100
counter clockwise
counter clockwise
18
VARIABLE DISPLACEMENT PUMP MA10VO/VSO, SERIES 31
19
VARIABLE DISPLACEMENT PUMP MA10VO/VSO, SERIES 31
20
VARIABLE DISPLACEMENT PUMP MA10VO/VSO, SERIES 31
13
21
VARIABLE DISPLACEMENT PUMP MA10VO/VSO, SERIES 31
22
VARIABLE DISPLACEMENT PUMP MA10VO/VSO, SERIES 31
23
VARIABLE DISPLACEMENT PUMP MA10VO/VSO, SERIES 31
24
VARIABLE DISPLACEMENT PUMP MA10VO/VSO, SERIES 31
25
VARIABLE DISPLACEMENT PUMP MA10VO/VSO, SERIES 31
26
VARIABLE DISPLACEMENT PUMP MA10VO, SERIES 31
Permissible Bending
Through Drive
Axial piston unit MA10VO can be supplied with a through drive, as shown in the ordering code on page 7 & 8.
The type of through drive is determined by codes (K01-K17). If the combination pump is not mounted in the
factory, the simple type code is sufficient.
Included with the pump are: Coupling sleeve, seals and necessary hardware.
Combination pumps
By mounting combination pumps circuits independent of each other are available for use.
1. If the combination pump consists of 2 MA10VO pumps and if these are to be delivered ready assembled,
then the two type codes are to be combined with a “+”.
2. If a gear pump, vane or other type pump is to be mounted in the factory as a second or third pump, please
consult the factory for available mounting information.
27
VARIABLE DISPLACEMENT PUMP MA10VO, SERIES 31
M1
M2
M3
M4
in. 6.5 8.03 14.53 15.67 7.24 9.02 15.51 16.65 8.54 10.51 17.01 18.15 10.83 13.31 19.8 20.94 10.83 13.78 20.28 21.42
MA10VO28
mm 165 204 369 398 184 229 3.94 423 217 267 432 461 275 338 503 532 275 350 515 544
in. 7.24 9.02 16.3 17.64 8.54 10.51 17.76 19.36 10.83 13.31 20.55 21.93 10.83 13.78 21.02 22.4
MA10VO45
mm 184 229 413 448 217 267 451 486 275 338 522 557 275 350 534 569
in. 8.54 10.51 19.06 20.63 10.83 13.31 21.85 23.43 10.83 13.78 22.32 23.9
MA10VO71
mm 217 267 484 524 275 338 555 585 275 350 567 607
28
VARIABLE DISPLACEMENT PUMP MA10VO, SERIES 31
30
VARIABLE DISPLACEMENT PUMP MA10VO/VSO, SERIES 52
Features
Axial piston pump MA10VO in swashplate design
is used in open loop circuits. Flow is proportional
to drive speed and displacement. By adjusting the
position of the swashplate it is possible to smoothly
vary the output flow of the pump.
– Port connections to SAE or metric – High power/weight ratio Long service life
– Operating pressure 3625 psi (250 bar) – Axial and radial loading of drive shaft
possible
– Good suction characteristics
– Wide range of controls
– Low noise level
– Through drive available
31
VARIABLE DISPLACEMENT PUMP MA10VO/VSO, SERIES 52
Technical Data
1. Input Operating Pressure Range
Absolute pressure at port S (A)
Pabs min .................. 11.6 PSI or (0.8 Bar)
Pabs max ................. 435 PSI or (30 Bar)
4. Direction of Flow
(“S” inlet port to “B” pressure port)
5. Table of values (theoretical values, without considering ηmh and ηv; values rounded)
Size 45 60
Displacement Vgmax cm 3
45 60
Max. Speed at Vgmax nomax rmp 2600 2700
Max. flow at nomax Qomax L/min 117 162
Max. power at nomax Pomax kW 49 68
Max. torque at Vgmax Tmax Nm 179 238
Hydraulic Formula
1. Determination of Size Vg = geometric displacement cu.in. or [cm3]
Imperial Metric per rev.
Vg ● n ● ηv Vg ● n ● η v
Flow Q= gpm L/min ∆p = differential pressure PSI or (Bar)
231 1000
n = speed [rpm]
Vg ● ∆p Vg ● ∆p
Torque T= lb-ft Nm ηv = volumetric efficiency
24 ● ● ηmh 20 ● ● ηmh
ηmh = mechanical-hydraulic efficiency
Q ● ∆p Q ● ∆p ηt = total efficiency (ηt = ηv ● ηmh)
Power P= HP kW
1714 ● ηt 600 ● ηt
Q = Flow (gpm) or (L/min.)
32
VARIABLE DISPLACEMENT PUMP MA10VO/VSO, SERIES 52
Ordering Code
MA10VS 0 45 DFR 52 R P S
Modes of operation
Pump, open circuit
Size
Control devices
Pressure control DR
G - Remote control DRG
Series
Series
52
Consult the factory for other series 50/53
Direction of rotation
clockwise R
Viewed on drive shaft
counter-clockwise L
Seals
FPM (fluorocarbon) V
Shaft end 45 60
SAE-splined shaft S
SAE-splined shaft, smaller size (not for pumps with thru drive) U
SAE-keyed shaft K
33
VARIABLE DISPLACEMENT PUMP MA10VO/VSO, SERIES 52
Ordering Code
C 62 N00
45 60
K02 &
101-2 SAE B 22-4 SAE B
K04
Service ports
(Pressure port B and Suction port S) 45 60
Mounting flange 45 60
SAE 2 Bolt hole C
= available
34
VARIABLE DISPLACEMENT PUMP MA10VO/VSO, SERIES 52
Fluid
1. Hydraulic Fluid
The MA10V open loop pump in the standard design should be used with a good quality, petroleum
based anti-wear hydraulic fluid.
At operating temperature
Optimum viscosity (opt) __80...170 SUS (16 / 36 mm2/s)
3. Temperature Range
4. Filtration
In order to ensure reliable operation of the axial piston unit, the operating fluid must be maintained
to a cleanliness class of 18/14 to ISO4406 or NAS 1638 class 9. As a guide the fluid cleanliness level
may be achieved using a 10 micron filter.
Installation Information
The pump housing must be filled with clean hydraulic fluid prior to pump start up and remain full.
The concentricity between the prime mover drive shaft and the pump shaft 0.05mm.
Installation Information
Prime mover drive shaft Pump shaft
.05mm
35
VARIABLE DISPLACEMENT PUMP MA10VO/VSO, SERIES 52
The pump housing must be filled with fluid both when commissioning and in
operation. In order to achieve low noise levels, all connecting lines (inlet, case
drain) should be isolated from the tank by flexible lines.
2. Horizontal Installation
- The pumps must be install so (L) or (L1) the case drain is at the top of the
pump
- If the minimum fluid level is below the ports of the pump, pipe the ports L
or L1 & S below the minimum oil level.
- Avoid mounting above the tank whenever possible in order to maintain a
low noise level.
- The permissible inlet height (h) is a result of the overall pressure loss, “A”
may not be greater then 32 inches (800 mm).
36
VARIABLE DISPLACEMENT PUMP MA10VO/VSO, SERIES 52
DR Pressure Control
Ports
B Pressure Port
S Suction port
L, L1 Case drain ports (L1 sealed)
Control Data
Hysteresis and repetitive accuracy p ………………. Max. 3 bar
Size 45 60
ΔP BAR 6 8
37
VARIABLE DISPLACEMENT PUMP MA10VO/VSO, SERIES 52
Pressure control DR
Version MA10VSO45DR/52R-XXC62/12NOO
38
VARIABLE DISPLACEMENT PUMP MA10VO/VSO, SERIES 52
DFR
Version MA10VSO45 DFR1/52L-XXC64N00
DRG
39
VARIABLE DISPLACEMENT PUMP MA10VO/VSO, SERIES 52
DFR
Version MA10VSO60 DFR1/52L-XXC62/12N00
DRG
X Port
40
VARIABLE DISPLACEMENT PUMP MA10VO/VSO, SERIES 52
DFR
Version MA10VSO60 DFR1/52L-XXC61/11N00
DRG
41
VARIABLE DISPLACEMENT PUMP MA10VO/VSO, SERIES 52
DFR
Version MA10VSO60 DFR1/52L-XXC61/11N00
DRG
42
NOTES
43
PTM022010-Rev2