Professional Documents
Culture Documents
Axial Piston Variable Pump A10VG Series 10: Features
Axial Piston Variable Pump A10VG Series 10: Features
A10VG Series 10
Features Contents
▶ Integrated boost pump for boost and pilot oil supply Type code 2
Hydraulic fluids 5
▶ Flow direction changes when the swashplate is moved
Working pressure range 6
through the neutral position Technical data 8
▶ High-pressure relief valves with integrated boost function HD – Proportional control, hydr., pilot-pressure related10
▶ Boost-pressure relief valve HW – Proportional control, hydr., mechanical servo 12
DA – Automatic control, speed related 14
▶ Optional with pressure cut-off
DG – Hydraulic control, direct operated 17
▶ Large variety of controls EP – Proportional control, electric 18
▶ Swashplate design EZ – Two-point control, electric 20
ET – Electric control, direct operated 21
ED – Electric pressure control 22
Dimensions, size 18 24
Dimensions, size 28 27
Dimensions, size 45 32
Dimensions, size 63 37
Dimensions, through drive 41
Overview of mounting options 44
Combination pumps A10VG + A10VG 45
High-pressure relief valves 46
Pressure cut-off 47
Mechanical stroke limiter 48
Stroking chamber pressure port X3 and X4 49
Measuring ports MA, MB, MH 50
Filtration in the boost pump suction line 51
Filtration in the boost pump pressure line 51
External boost pressure supply 52
Connector for solenoids 53
Rotary inch valve 54
Installation dimensions for coupling assembly 55
Installation instructions 56
Project planning notes 59
Safety instructions 60
Type code
01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22
A10V G / 10 ‒ N C
Operating mode
02 Pump, closed circuit G
Size (NG)
03 Geometric displacement, see "Technical data" on page 8 18 28 45 63
Control device 18 28 45 63
04 Proportional control pilot-pressure related, with inlet filtration in P and X1/X2 ● ● ● ● HD3
hydraulic mechanical servo ● ● ● ● HW
Automatic control, speed related 1)
U = 12 V – ● ● ● DA1
U = 24 V – ● ● ● DA2
Hydraulic control direct operated ● ● ● ● DG
Proportional control, electric with proportional solenoid with inlet filtration in P and X1/X2 U = 12 V ● ● ● ● EP3
U = 24 V ● ● ● ● EP4
Two-point control, electric with switching solenoid U = 12 V ● ● ● ● EZ1
U = 24 V ● ● ● ● EZ2
Electric control, direct operated U = 12 V – ● ● – ET3
two pressure reducing valves (FTDRE) U = 24 V – ● ● – ET4
Electric pressure controller, de-energized, stroking chamber is controlled via X1 U = 24 V – ● ● ● ED2
negative control,
with 4/2 directional valve and de-energized, stroking chamber is controlled via X2 U = 24 V
– ● ● ● ED4
one pressure reducing valve1)
Pressure cut-off 18 28 45 63
05 Without pressure cut-off (without code) ● ● ● ●
With pressure cut-off – ● ● ● D
01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22
A10V G / 10 ‒ N C
Series
10 Series 1, index 0 10
Direction of rotation 18 28 45 63
11 Viewed on drive shaft clockwise ● ● ● ● R
counter-clockwise ● ● ● ● L
Sealing material 18 28 45 63
12 NBR (nitrile rubber), shaft seal made of FKM (fluoroelastomer) ● ● ● ● N
Drive shaft 18 28 45 63
13 Splined shaft for single pump ● ● ● ● S
ANSI B92.1a–1976 for combination pump – ● ● ● T
Mounting flange 18 28 45 63
14 SAE J744 2-hole ● ● ● ● C
Working port
15 Port thread: Metric with profile sealing ring sealing according to DIN 3852
Fastening thread at the SAE working port and through drive: Metric according to DIN 13 18 28 45 63
SAE working port A and B, same side left suction port S bottom – ● ● ● 10
SAE working port A and B, same side right suction port S at top
– ● ● ● 13
(externally piped up, except for DG)
Port and working port thread: Metric with profile sealing ring sealing according to DIN 3852
Fastening thread at the through drive: Metric according to DIN 13 18 28 45 63
Threaded port A and B, same side right suction port S bottom ● – – – 16
Boost pump 18 28 45 63
16 Without integrated boost pump without through drive ● ● ● ● N
with through drive ● ● ● ● K
Integrated boost pump with and without through drive ● ● ● ● F
01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22
A10V G / 10 ‒ N C
Through drive3) 18 28 45 63
17 Without through drive, only for version N and F (position 16) ● ● ● ● 00
Flange SAE J744 Hub for splined shaft4)
82-2 (A) 5/8 in 9T 16/32DP ● ● ● ● 01
3/4 in 11T 16/32DP – ● ● ● 52
101-2 (B) 7/8 in 13T 16/32DP ● ● ● ● 02
1 in 15T 16/32DP – ● ● ● 04
127-2 (C) 1 1/4 in 14T 12/24DP – – – ● 07
Flushing valve 18 28 45 63
21 Without flushing valve (without code) ● ● ● ●
Flushing valve SAE connection diagram, metric mounting ● ● ● ● 1
metric threaded ports ● ● ● ● 3
Standard/special version
22 Standard version without code
Special version -S
Notice
▶▶ Note the project planning notes on page 59!
▶▶ In addition to the type code, please specify the
relevant technical data when placing your order.
▶▶ Please note that not all type code combinations are
available although the individual functions are marked
as being available.
3) Specifications for version with integrated boost pump, 5) Pressure filtration is not possible in connection with
please contact us for version without boost pump DA control valve
4) Hub for splined shaft according to ANSI B92.1a-1976 6) Connectors for other electric components may deviate
(drive shaft allocation according to SAE J744)
▼▼ Version ED2
MB
MA
Switching solenoid B; A
X1
Counter-
clockwise
Clockwise
X2
Pressure reducing valve MB; MA
▼▼ Version ED4
MA
X1 B; A
Counter-
clockwise
Clockwise
X2 MB; MA
Dimensions, size 18
143.7
(G) 133.4
(PS) 118.9 87 (PS;G)
98.4 58.5 (T1)
85.6 1.9
9.5 T1 X1 R X2 MB
Mechanical
neutral position PS B G
T1
119.7
adjustment
105.5
PS
83
-0.054
15
W
25 25
0
⌀101.6
T2
65
68
(A)
133.4 View W
X1
PS
107.7
100.8
99.5
76.5
59.5
R G
51
42
14
51
86.5
109.5
107.7
83
X2
MB; MA
HD valve:
65.1 B; A without bypass
129.9 with bypass
Center of gravity
5/16-18UNC-2B2) 33
19
6
⌀30
⌀65
25
41
1) Involute spline according to ANSI B92.1a, 30° pressure angle, flat 6) The countersink can be deeper than specified in the standard.
root, side fit, tolerance class 5 Ports designed for straight stud ends according to EN ISO 9974-2
2) Thread according to ASME B1.1 type E
3) Depending on the application, momentary pressure peaks can 7) O = Must be connected (comes plugged)
occur. Keep this in mind when selecting measuring devices and X = Plugged (observe installation instructions)
fittings.
4) Plugged for external boost pressure supply.
5) Depending on installation position, T1 or T2 must be connected
(see also installation instructions on page 56).
▼▼ HD – Proportional control, hydraulic, pilot-pressure related ▼▼ HW – Proportional control, hydraulic, mechanical servo
143.6 63 9
98.4 50
27
8
Y2, Y1
⌀8
Version with
126.9
neutral position
83
switch, HWL
Y1 38.7
33°
a
20
±1
1
33° ±
b
38.7
Y2 109.4
98.4
PS
105.5
120
84
X1
100.4
51
51
100.4
65.1 X2
Dimensions, size 28
130.4
102
93.7 1.6
Pressure cut-off
(PS) 88.5
(X1;X2)
X1 R X2
9.5 PS T1
Mechanical
neutral position
(Fe)
MB G
(T1)
adjustment
116
91.2
65.5
Fe
(G)
-0.054
15
59
49
W
0
⌀101.6
(PS)
19.1
23
49
71
(T2) T2
Flange SAE J744
S
(S)
101-2 (B)
T2 MA S
Boost pressure
(T1;T2) 92.5 valve (T2) 59
(G) 164.9 146
(S) 165.9 174
168.9
215.3
View W
175.9(B;A) 23.8
169.9(Fe)
B
(B;A)
R X1 T1 B; A
(T1)
max. 134
⌀19
107.7
129
Fe
99
50.8
73
59
37.5 37.5
49
(G)
49
62
65
50.8
80.5
107.7
94.5
99
129
⌀19
A
(PS)
X2
61.4
PS MB; MA G
23.8
HD valve:
without bypass
with bypass
Center of gravity
7/16-14UNC-2B2)
3/8-16UNC-2B2) 38 48
22 28
7.5 9.5
⌀35
⌀35
⌀72
⌀72
30 40
46 56
1) Involute spline according to ANSI B92.1a, 30° pressure angle, 6) Depending on installation position, T1 or T2 must be connected
flat root, side fit, tolerance class 5 (see also installation instructions on page 56).
2) Thread according to ASME B1.1 7) The countersink can be deeper than specified in the standard.
3) Depending on the application, momentary pressure peaks can Ports designed for straight stud ends according to EN ISO 9974-2
occur. Keep this in mind when selecting measuring devices and type E
fittings. 8) Optional, see page 49
4) Only dimensions according to SAE J518, metric fastening thread is 9) O = Must be connected (comes plugged)
a deviation from the standard. X = Plugged (in normal operation)
5) Plugged for external boost pressure supply.
▼▼ HD – Proportional control, hydraulic, pilot-pressure related ▼▼ HW – Proportional control, hydraulic, mechanical servo
138.9 63 9
93.7 50
27
Y2, Y1
8
⌀8
134.1
Version with
91.2
neutral position
switch, HWL
Y1
38.7
33°
a
20
±1
1
33° ±
38.7
b
Y2 104.7
X1, X2 130.3
PS
116
92.2
X1
100.4
49
49
61.4 100.4
X2
141.2
118.2
97.7
121
92.2
105.5
105.5
124.8
137.1 137.1
131.2
150.7
132.2
150.7
132.2
92.2
175.9
131.2 175.9
100.4
86
86
100.4
100.4
DA control valve
▼▼ DA..2 – fixed setting ▼▼ DA..3 – mechanically adjustable with position lever
Direction of actuation
130.3 ⌀8 "clockwise" (3R)
(G) 178.4
130.3 ° 70
70 °
9
92.2
63
15.5
50
92.2
27
15.5
G
7
Direction of actuation 20
G
7
"counter-clockwise" (3L)
100.4
100.4
(G)
81(G)
100.4
100.4
max. 156
81
max. 162
156.2
G
164.9 164.9
8
(G) 178.4
▼▼ DA..7 – fixed setting and ports for pilot control device ▼▼ DA..8 – fixed setting and inch valve mounted
128.9
112.2
112.2
92.2
92.2
59
(Z)
(PS)
(Y)
G
15.5
15.5
7
7
(Y) 102.2 G
100.4
100.4
65 (PS)
(G)
(G)
59 (Z)
100.4
100.4
81
81
max. 156
max. 156
PS Y G Z G
164.9 164.9
Dimensions, size 45
(G) 178.6
142.1
110 83.5 (G)
105.4 (T1) 68 68 (PS)
Pressure cut-off
(PS) 100 1.3
9.5 X1 Fe R X2
T1 PS MB G
Mechanical
neutral position
adjustment
(Fe)
T1 PS
(PS)
(T1)
123.5
99.5
G
71.5
(G)
68
-0.054
15
55
B
0
⌀101.6
W
21.2
23
A
48
74.5
(T2)
Flange SAE J744 T2
(S)
101-2 (B)
T2 MA S Boost pressure S
(T1;T2) 100 valve
(S) 176.6 (T2) 68
187.1 146
230.3 174
X1 B; A
(B;A)
max. 134
133.5
⌀19
(X1)
107.7
103.5
Fe
78
50.8
49
R
37.5 37.5
49
65.5
50.8
107.7
97.5
91.5
121.5
(X2)
⌀19
Center of gravity
7/16-14UNC-2B2)
3/8-16UNC-2B2) 38 48
22 28
7.5 9.5
⌀40
⌀40
⌀80
⌀80
30 40
46 56
1) Involute spline according to ANSI B92.1a, 30° pressure angle, 6) Depending on installation position, T1 or T2 must be connected
flat root, side fit, tolerance class 5 (see also installation instructions on page 56).
2) Thread according to ASME B1.1 7) The countersink can be deeper than specified in the standard.
3) Depending on the application, momentary pressure peaks can Ports designed for straight stud ends according to
occur. Keep this in mind when selecting measuring devices and EN ISO 9974-2 type E
fittings. 8) Optional, see page 49
4) Only dimensions according to SAE J518, metric fastening thread is 9) O = Must be connected (comes plugged)
a deviation from the standard. X = Plugged (in normal operation)
5) Plugged for external boost pressure supply.
▼▼ HD – Proportional control, hydraulic, pilot-pressure related ▼▼ HW – Proportional control, hydraulic, mechanical servo
63 9
150.7
50
105.4
27 ⌀8
8
Y2, Y1
142.4
99.5
Version with
neutral position
switch, HWL
Y1
38.7
33°
a
±1
20
±1
3 3°
38.7
b
Y2 116.4
X1, X2
141.4
PS
123.5
100.5
X1
100.4
49 49
100.4
65.5 X2
152.9
129.9
109.4
100.5
105.5
105.5
126.8
148.8 148.8
142.9
140.5
159
140.5
159
100.5
188.1
142.9 188.1
100.4
98
98
100.4
100.4
DA control valve
▼▼ DA..2 – fixed setting ▼▼ DA..3 – mechanically adjustable with position lever
9
100.5
100.5
63
22
50
G
27
22
20 G
11
Direction of actuation
11
"counter-clockwise" (3L)
100.4
100.4
(G)
(G)
83.5
83.5
100.4
100.4
max. 194.7
max. 159
159.2
G
G
8
178.6
178.6
(G) 199.6
▼▼ DA..7 – fixed setting and ports for pilot control device ▼▼ DA..8 – fixed setting and inch valve mounted
136.8
120.5
120.2
100.5
100.5
22
68
(Z)
(PS)
(Y)
(Y) 113.9
22
G
11
G
11
100.4
100.4
(PS)
(G)
(G)
(Z)
68
59
83.5
100.4
83.5
100.4
max. 159
max. 159
Z
PS Y G G
178.6 178.6
Dimensions, size 63
(G) 187.8
145
(PS) 120 93.5 (G)
109.5 (T1) 75 72 (PS)
108.3 0.7
Pressure cut-off
12.7 X1 Fe R Fa X2
T1 PS
Mechanical
neutral position
(Fe,Fa)
adjustment
MB G PS
(PS)
(T1)
137
T1
111.1
G
(G)
82.5
64.5
76
-0.063
18
B
W
0
⌀127.6
25
30.5
(T2) 54.5
A
85.5
79
T2
Flange SAE J744
127-2 (C)
(S)
T2 MH MA Boost pressure valve MH S
(T1;T2) 109.5 S
(S) 184.3 (T2) 75
194.8 181
238.2 213
(B;A) 195.8
View W
(Fe;Fa) 189.8 23.8
X1 T1 B; A
(B;A)
B
(X1)
max. 134
138.5
19.5 (Fe)
⌀19
108.5
107.7
Fe
90
50.8
69
37.5 37.5
R 50.8
69
Fa
107.5
75
107.7
(Fa) 19.5
108.5
138.5
⌀19
(X2)
76.5 X2 PS MB; MA
23.8
HD valve:
without bypass
with bypass
Center of gravity
7/16-14UNC-2B2)
7/16-14UNC-2B2)
48 48
28 28
9.5 9.5
⌀40
⌀40
⌀68
⌀68
40 40
56 56
1) Involute spline according to ANSI B92.1a, 30° pressure angle, 6) Depending on installation position, T1 or T2 must be connected
flat root, side fit, tolerance class 5 (see also installation instructions on page 56).
2) Thread according to ASME B1.1 7) The countersink can be deeper than specified in the standard.
3) Depending on the application, momentary pressure peaks can Ports designed for straight stud ends according to
occur. Keep this in mind when selecting measuring devices and EN ISO 9974-2 type E
fittings. 8) Optional, see page 49
4) Only dimensions according to SAE J518, metric fastening thread 9) O = Must be connected (comes plugged)
is a deviation from the standard. X = Plugged (in normal operation)
5) Plugged for external boost pressure supply.
▼▼ HD – Proportional control, hydraulic, pilot-pressure related ▼▼ HW – Proportional control, hydraulic, mechanical servo
153.6 63 9
108.3 50
27
Y2, Y1
8
⌀8
154.5
Version with
111.1
neutral position
switch, HWL
Y1
38.7
33°
a
20
±1
3 3 ° ±1
38.7
b
Y2 119.3
X1, X2 144.9
PS
137
112.1
X1
100.4
69
69
100.4
76.5 X2
151.7 151.7
145.8
170.6
152.1
170.6
152.1
112.1
195.8
145.8 195.8
100.4
95.9
95.9
100.4
100.4
DA control valve
▼▼ DA..2 – fixed setting ▼▼ DA..3 – mechanically adjustable with position lever
Direction of actuation
144.9 ⌀8 "clockwise" (3R)
(G) 205.3
° 70
144.9 70 °
9
112.1
63
112.1
50
25
27
Direction of actuation
4.5
25
G 20 G
4.5 "counter-clockwise" (3L)
100.4
100.4
(G)
93.5 (G)
100.4
93.5
max. 189.5
max. 153.5
100.4
157.5
G
8
G
186.3 186.3
(G) 205.3
▼▼ DA..7 – fixed setting and ports for pilot control device ▼▼ DA..8 – fixed setting and inch valve mounted
148.8
132.1
132.6
112.1
112.1
25
(PS) 76
(Z)
(Y)
G G
25
4.5
4.5
(Y) 116.8
100.4
100.4
72 (PS)
(G)
(G)
59 (Z)
100.4
max. 153.5
max. 153.5
100.4
93.5
93.5
PS Y G Z G
186.3 186.3
▼▼ N00 – without boost pump, without through drive / F00 – with boost pump, without through drive
NG A1 (N00) A1 (F00)
N00 − without boost pump F00 − with boost pump 18 169.4 169.4
28 201.7 215.3
45 216.8 230.5
63 224.5 238.2
A1 A1
▼▼ F01/K015)
106.4 A2
A3
A4
A1 (to mounting flange)
F52/K525)
82-2 (A) NG A1 A22) A3 A4 A53)
O-ring4) 28 219.1 min. 8.8 9 37.6 M10 × 1.5; 13 deep
A5
45 234.5 min. 8.8 9 38
63 242 min. 8.8 9 37
ø82.55+0.010
+0.035
106.4 A2
A3
A4
A1 (to mounting flange)
▼▼ F02/K02; F04/K045)
146 A2
A3
A4
A1(to mounting flange)
▼▼ F07/K075)
+0.010
ø127+0.050
181 A2
A3
A4
A1 (to mounting flange)
Notice
The mounting options listed only apply for drive shaft
versions with undercut. Please contact us for drive
shafts without undercut.
Total length A
A10VG A10VG 2nd pump1)
1st pump NG18 NG28 NG45 NG63
NG18 356.8 ‒ ‒ ‒
NG28 389.6 435.5 ‒ ‒
NG45 404.9 450.8 466.0 ‒
NG63 412.6 458.5 473.7 487.7
A10VG A10VG
(pump 1) (pump 2)
Notice
▶▶ The combination pump type code is shown in
shortened form in the order confirmation.
▶▶ The permissible through-drive torques are to be
observed (see page 9).