Incinerator
Incinerator
Incinerator
kW
kW
kW
kg/s
kg/hr
Combustion Intensity 1405 Btu/cu.ft.hr #4 waste
5425 # 3waste
Total Heat Input 204996 kJ/hr
Required Chamber Volume 4.13 cu.m # 4 waste
1.07 cu.m #3 waste
LPG burner capacity 9.8 kW
Combustion air flow rate (Waste+LPG) 72 cfm
Total gas flow rate within the chamber 236 kg/hr
139 cfm
0.066 cu.m/s
Recommended residence time of gas within the chamber 1s
Length of the burning chamber 0.8 m
Required diameter of the burning chamber 0.32 m
12.7 inch
LPG Burner Power requirement 70 kW
Flue Gas Flow rate 235.9 kg/hr
Flue Gas Temperature 1400 Celsius
Recommended Flue gas temperature 250 Celsius
Energy Released From Flue Gas 358147.6 kJ/hr
99.48545 kJ/s
Overall Heat Transfer Coefficient 40
Cold Fluid outlet temperature 200
LMTD 577.6772
Required HE surface Area 4.305409 sq.m
Length of the circular chamber 0.5 m
No.of Pipe Turns 80
Diameter of circular pipe 1.35 inch