RT Acceptance Criteria
RT Acceptance Criteria
RT Acceptance Criteria
ACCEPTANCE CRITERIA
Sl. TYPE OF ASME SEC. – 8 Div. – 1,
No. DEFECT API-1104 Para. – UW – 52
1. Crack Shallow / Crater crack <4mm None
2. Lack of fusion a) Individual < 1” (25mm) None
(IF) b) Cumulative < 1” in any 12” weld length.
3 IFD a) Individual < 2” (50mm)
b) Cumulative < 2” in any 12” weld length
4. Incomplete a) Individual length < 1” (25mm) 2/3 t where t is the thickness
penetration (IP) b) Cumulative < 1” in any 12” weld length of the weld excluding
c) < 8% of W L allowed reinforcement.
5 IPD a) Individual length < 2” (50mm)
b) Cumulative < 3” (76) in any 12” weld length
6 ICP a) Individual length < 2” (50mm)
b) Cumulative < 2” (50) in any 12” weld length
4. Porosity
a) Individual < 3 mm. or 25% of WT
b) Cluster Diameter of CP < 13 mm.
Cumulative CP < 13 mm. in any 12” WL
Individual por. with in a cluster < 2 mm.
c) Hollow bead Length of HB < 13 mm.
(HB) Cumulative length of HB < 50 mm. in any 12” WL.
Individual HB > 6 mm. in length, separated by 50
mm.
5. B.T Dimension of BT < ¼” (6.5 mm.) and density of BT
< thinnest base metal.
6. U.C a) Cumulative length of EU & IU < 2” (50 mm.) in
any 12” WL.
b) Sum of EU & IU in any combination < 1/6” WL.
7. Slag, TI, a) Isolated (ISI) < ½” in 12” WL With <3 mm.
Elongated b) ESI < 2” With < 1.6 mm.
inclusion c) Cum. Length of ESI < 2”. (Pipe OD > 2-3/8”.
8.