GENERAL NOTES

ROOF BEAM DETAILS 1. These Structural Details are to be read in conjunction


with the Architectural Drawings and any discrepancies
should be notified immediately.
2. Only figured dimensions to be used.

A B D E F NOTES ON REINFORCED CONCRETE


1. Reinforced concrete mix:
Grade 25 for pile caps, footings and columns.
Grade 25 for beams and slabs.
150
2Y12 2Y12 2Y12 2Y12 2. Concrete cover to M.S. Bars (not otherwise shown)
4 4 4 Footings ............................................................. 50mm.
Ground beams & columns below ground ......... 38mm.
Columns above ground ..................................... 25mm.
Superstructure beams ........................................ 25mm.
Superstructure slabs .......................................... 13mm.
R8@200c/c. R8@200c/c. R8@200c/c. R8@200c/c.

450
3. All reinforced concrete to be Mechanically vibrated or
directed by the ENGINEER.
4. Portland cement used to comply to B.S. 12.
5. Coarse & fine aggregates to comply to B.S. 882.
4 4 4 6. All steel bars to comply to B.S. 4449:1997
4-4 7. R means mild steel Bar.
2Y16 2Y16 2Y16 2Y16 Y means H.Y.S. Bar.
8. Example:
3000 3000 3000 3000

3Y20
Y10-150
RB.3 (A-F)Same RB.D (5-1) 9. Lap lengths:
Mild steel bar in compression : 39 Dia.
in tension : 39 Dia.
(150mm.x450mm.) High tensile bar in compressin : 40 Dia.
in tension : 41 Dia.

5 4 2 1 D1 E1 F
APPROVED
NO. AMENTMEND DATE BY

2Y12 2Y12 2Y12 2Y12


4 4 4 4

R8@200c/c. R8@200c/c. R8@150c/c. R8@150c/c. R8@150c/c. A1 AMENDMENT BEAM & SLAB DETAILS MARCH 2018 IR.A.HALIM

OWNER'S NAME, SIGNATURE & COMPANY CHOP :

4 4 2Y16
4 2Y16
4
2Y16 2Y16

3658 3658 3658 2715 2715

RB.A Same RB.D,F (5 TO 1) RB.7 Same RB,12 (D1 TO F)


(150mm.x450mm.) (150mm.x450mm.)
.................................................................
OWNER/CLIENT'S SIGNATURE

12 9a 7 5 PROJECT TITLE:

150
MEMBINA BANGUNAN TAMBAHAN
2Y12 2Y12 2Y12 8 2Y12
4 4 MASJID JAMEK, AIR KUNING
PERAK

300
R8@150c/c.
R8@200c/c. R8@150c/c. R8@150c/c.

8
2Y12 8-8
4 4
2Y16 2Y16 2Y16
2742 2742 2438 1830

DRAWING TITLE :

RB.D1 Same RB,F (12 TO 5) RB.W (150mm.x300mm.) - ROOF BEAM DETAILS

(150mm.x450mm.)

150
150 2Y12 2Y12
2Y12
4 4 4

400
R8@150c/c. R8@150c/c. R8@150c/c. R8@150c/c. R8@150c/c. R8@150c/c.
450

ENGINEER'S SIGNATURE :
R8@150c/c. R8@150c/c. R8@150c/c. R8@150c/c.
"I hereby certify that the details are to the best of my knowledge and belief
in accordance with the British Standard Code of Practice CP 110/B.S. 8110
2Y16 4-4 4 (1997) and that I will accept full responsibility for the design and supervision
of work."
2Y16 4-4 4 2Y16
4
5480
5480 3040

RB.E2 (7 TO 12) RB.Y (150mm.x350mm.)


RB.X(150mm.x450mm.)
(150mm.x400mm.)

CONSULTANT :

WATER TANK BEAM DETAILS

2Y12 2Y12 2Y12 2Y12


4 4 4 4

R8@150c/c. R8@125c/c. R8@150c/c. R8@125c/c.

4 2Y16
4 2Y16
4 2Y16
4 2Y16
DRAWN BY IDA
DESIGN BY LIANA
CHECKED BY IR. ABDUL HALIM BIN HASHIM
2430 1800 2430 1800 APPROVED BY IR. ABDUL HALIM BIN HASHIM
SCALE 1:25

RB.B (150mm.x350mm.) RB.A (150mm.x350mm.) RB.B (150mm.x350mm.) RB.A (150mm.x350mm.) DATE JAN. 2018

DRAWING NO. : REV.


AH0118/MJD/S/5 A1