Moment End-Plate Connection Design (Flush Type)

Design Forces

Design Moment M = 1600 kNm 14161.60 k-in


Design Shear V = 40 kN 8.99 kips
Axial force P = 75 kN 16.90 kips
*-*ve for comression and *+*ve for tension
Consider

End-late material yield stress, Fpy= 345 N/mm^2 50.0 ksi


Nominal Tensile strength of Bolts, F t= 620 N/mm^2 89.9 ksi ,90 ksi for A 325, 113 ksi for A490
Allowable shear stress of bolts= 72 N/mm^2 10.4 ksi
φ= 0.75
φb= 0.90

Geometric Design Data


Width of flange, bf = 200.00 mm 7.87 inch
End plate width, bp = 200.00 mm 7.87 inch
Thickness of flange, tf = 11.00 mm 0.43 inch
Bolt gage, g = 70.00 mm 2.76 inch
pf = 50.00 mm 1.969 inch
pb = 90.00 mm 3.54 inch
h= 1340.00 mm 52.76 inch
Web thickness, tw 8.00 mm 0.31 inch
Number of rows of bolt,n = 5

Calculate
d1 = 1400 mm 55.12 inch
d2= 1310 mm 51.57 inch
d3= 1220 mm 48.03 inch
d4= 1130 mm 44.49 inch
d5= 1040 mm 40.94 inch
∑dn= 6100 mm 240.16 inch
h1= 1395 mm 54.9 inch
h5= 1035 mm 40.7 inch
γr = 1.25 for flush connections

Maxial= P/2*(h-tf)
= 50 kNm 442.13 k-in
M= M+Maxial
= 1650 kNm 14604 kips
Mu= 1.5*(M+Maxial)
= 2475 kNm 21905.59 k-in
Flange Force, Ff= M/(h-tf)
= 1221 kN 274.56 kips

1. required bolt dia, db,req


= (2*Mu /(∏*φ*Ft*∑dn))^0.5
= 23.6 mm 0.928 inch
Acceted, db = 24 mm 0.9 inch

2. Solve for end plate thickness, tp,reqd,

s= 1/2*(bp*g)^0.5
= 59 mm 2.33 inch
pf = 50.00 mm 1.97 inch ≤s 50.00 mm = pf, use
Y= bp/2*(h1/pf+h2/s)+2/g*(h1*(pf+0.75pb)+h2*(s+0.25*pb)) + g/2
= 25086 mm 987.6 inch
Pt= ∏*db *Ft/4
2

= 280 kN 63.05 kips


φMnp= φ(2*Pt*(∑dn))
= 1140 kNm 10091.3 k-in

tp,reqd = sqrt(1.1*γr*(φMnp)/(φb*Fpy*Y))
= 14.2 mm 0.559 inch
Use, tp = 15.0 mm
3. Check for Shear

Shear per bolt (V/(2*n)) = 0.90 kips 4 kN


Shear capacity per bolt = 7.32 kips 33 kN ≥ Applied shear per bolt ok

4. Weld design
a) Top Flange to end plate weld
Dreqd= Ff/((2*(bf -tf)-tw)*0.928)
= 20.3 sixteenths
Use 21 /16 inch fillet welds

b) Beam web to end plate weld


D= 0.6*Fy*tw/(2*0.928)
5.09 sixteenths
Use 6 /16 inch fillet welds
AISC, Table 1D
-7.713 ### 0.1753 44.0

Nominal Dia
Bolt
Nominal
Allowable Shear
of Bolt (A325N)
ShearArea
Stress (Spec -- TableJ3.2)
( mm( )Kips( )sq in) ( ksi)