Steeltek Connection
Steeltek Connection
Design Forces
Consider
Calculate
d1 = 1200 mm 47.24 inch
d2= 1110 mm 43.70 inch
d3= 1020 mm 40.16 inch
d4= 930 mm 36.61 inch
d5= 840 mm 33.07 inch
d6= 750 mm 29.53 inch
d7= 660 mm 25.98 inch
h1= 1195 mm 47.0 inch
h2= 655 mm 25.8 inch
γr = 1.25 for flush connections
Maxial= P/2*(h-tf)
= -442.13 k-in
M= M1-Maxial
= 15842.87 kips
Mu= 1.5*(M-Maxial)
= 24427.50 k-in
Flange Force, Ff= M/(h-tf)
= 297.86 kips
s= 1/2*(bp*g)^0.5
= 2.33 inch 59 mm
pf = 50.00 mm ≤s 50.00 mm = pf, use
= 1.97 inch
Y= bp/2*(h1/pf+h2/s)+2/g*(h1*(pf+0.75pb)+h2*(s+0.25*pb)) + g/2
= 357.0 inch 9067.47 mm
Pt= ∏*db *Ft/4
2
= 68.48 kips
φMnp= φ(2*Pt*(∑dn))
= 9341.5 k-in
tp,reqd = sqrt(1.1*γr*(φMnp)/(φb*Fpy*Y))
= 0.894 inch 23.0 mm
4. Weld design
a) Top Flange to end plate weld
Dreqd= Ff/((2*(bf -tf)-tw)*0.928)
= 22.0 sixteenths
Use 23 /16 inch fillet welds
Nominal Dia
BoltNominal
Allowable Shear
of Bolt (A325N)
ShearArea
Stress (Spec -- TableJ3.2)
( mm()Kips( )sq in) ( ksi)