A Thermodynamic Properties of Ammonia-Water Mixture
A Thermodynamic Properties of Ammonia-Water Mixture
A Thermodynamic Properties of Ammonia-Water Mixture
A.1 INTRODUCTION
Figure A.1 shows the details of bubble point and dew point temperature
variations with ammonia concentration at a fixed pressure. The loci of all the bubble
points have called as the bubble point curve and the loci of all the dew points have
126
called as the dew point curve. The bubble point curve is the saturated liquid line and
the dew point curve is the saturated vapor line and the region between the bubble and
dew point lines is the two-phase region where both liquid and vapor coexist in
equilibrium. The region below the saturated liquid line is sub cooled liquid region and
the region above the saturated vapor line is superheated vapor region.
The bubble and dew point temperatures of the ammonia-water mixture have
been determined from the equations (1) and (2). The coefficient values for equations
A.1 and A.2 are given in table A.1 and A.2 respectively for bubble point temperature
and dew point temperature.
ni
P0
Tb P, x T0 a i 1 x ln P
mi
(A.1)
i
ni
P0
Td P, y T0 a i 1 x ln P
mi
(A.2)
i
i mi ni ai
1 0 0 +0.322302 101
2 0 1 -0.384206 100
3 0 2 +0.460965 10-1
4 0 3 -0.378945 10-2
5 0 4 +0.135610 10-3
6 1 0 +0.487755 100
7 1 1 -0.120108 100
8 1 2 +0.106154 10-1
9 2 3 -0.533589 10-3
10 4 0 +0.785041 101
11 5 0 -0.115941 102
12 5 1 -0.523150 10-1
13 6 0 +0.489596 101
14 13 1 +0.421059 10-1
Table A.2 Exponents and coefficients of equation (A.2) to determine dew point
temperature
i mi ni ai
1 0 0 +0.324004 101
2 0 1 -0.395920 100
3 0 2 +0.435624 10-1
4 0 3 -0.218943 10-2
5 1 0 -0.143526 101
6 1 1 +0.105256 101
7 1 2 -0.719281 10-1
8 2 0 +0.122362 102
9 2 1 -0.224368 101
10 3 0 -0.201780 102
11 3 1 +0.110834 101
12 4 0 +0.145399 102
13 4 2 +0.644312 100
14 5 0 -0.221246 101
15 5 2 -0.756266 100
16 6 0 -0.135529 101
17 7 2 +0.183541 100
128
Start
Input of P, T and x
No
Yes Assign properties of liquid
T < BPT mixture (sub-cooled)
No
Yes Assign properties of vapor
T = DPT mixture (saturated)
No
Yes Assign properties of
T > BPT and T < DPT liquid vapor mixture
BPT
No
Yes Assign properties of vapor
T > DPT mixture (superheated)
End
Fig.A.2 Flowchart for thermodynamic properties of ammonia-water mixture at five
regions
129
Figure A.2 shows the flowchart to solve the properties in the five regions viz: sub
cooled region, saturated liquid region, two-phase region, saturated vapor region and
superheated region.
The actual state out of five regions has been identified from the given
temperature, pressure and concentration. It can be done by comparing the temperature
with bubble point and dew point temperatures. If the temperature is less than the
bubble point temperature, the region is sub cooled or compressed liquid. If the
temperature is equal to the bubble point temperature, it is a saturated liquid region. In
case the temperature lies between bubble point temperature and dew point
temperature, the region is liquid-vapor mixture. Saturated vapor region is the one
obtained when the temperature obtained is equal to the dew point temperature.
Finally if temperature exceeds the dew point temperature, it is a superheated region.
The energy and exergy properties have derived from Gibbs free energy
function. In liquid phase the Gibbs free energy for both liquid and gas phases have
determined from equations (A.3) and (A.4), respectively.
h m xh m (1 x) h L hE (A.3)
L NH H O
3 2
The following equations (A.4) to (A.14) have specified the liquid enthalpy
calculation. TB=100 K, PB=10 bar, Tr=T/ TB, Pr=P/ PB respectively.
Gr
h RTB Tr2 (A.4)
Tr Tr Pr
T P
Cp T
G h o Tso C p dT vdp T dT (A.5)
To
To Po
T
130
L
h ro T r s ro
L
B 1 T r Tro
B2 2
2
T r Tro
2
B3 3
3
3
Tr Tro
Gr
L Tr
B1Tr ln B 2 Tr Tr Tro
B3 2
Tr Tro Tr
2
(A.6)
Tro 2
A1 A 3 Tr A 4 Tr Pr Pro 2 Pr Pro
2 A
2
2 2
h ro L T B T B
2
2 Tro 3
s ro B1 1 ro 2 Tr ro 3 Tr
L
Tr Tr 2 Tr 3 Tr
T
L
Gr B
B1 ln r B 2 Tr Tro 3 Tr Tro
2 2
(A.7)
Tr ro
T 2
A
Tr
1 A 3 A 4 Tr Pr Pro A 2 Pr 2 Pro 2
2Tr
h ro L T B T 2 B B
2 B1 ro2 2 B 2 ro 2 1 B 2 3 2Tr
G r Tr Tr 2 2Tr Tr 3
L
(A.8)
Tr Tr B T 3 A1
3 ro
3 T2 B 3 Tr
A 4
2
Pr Pro
A2
2
Pr Pro
2 2
r Tr 2Tr
2 Gr
ro
L B
2
2 2
B
h B1 Tro Tr 2 Tro Tr 3 Tro Tr
3
3 3
Tr (A.9)
Tr Tr
4 r 1
A T 2 A P P A 2 P 2 P 2
r ro
2
r ro
L B
2
2
2 B
h ro B1 Tro Tr 2 Tro Tr 3 Tro Tr
3
3 3
h L RT B (A.10)
4 r 1 r ro
A
A T 2 A P P 2 P 2 P 2
2
r ro
The above equation (A.10) is used for finding liquid enthalpy for water and ammonia.
The Gibbs excess energy GrE for liquid mixtures has been expressed in equation A.11
E
G r F1 F2 2x 1 F3 2x 1 1 x
2
(A.11)
F1 E1 E 2 Pr E 3 E 4 Pr Tr
E5 E6
(A.12)
Tr Tr 2
E11 E12
F2 E 4 E 8 Pr (E 9 E10 Pr )Tr 2 (A.13)
Tr Tr
131
E 15 E 16
F3 E 13 E14 Pr 2 (A.14)
Tr Tr
GrE
h RTB Tr
E 2
T (A.15)
Tr
r
Pr ,x
2E 5 3E 6
- E1 E 2 Pr 2
Tr Tr
2E11 3E12
h RTB (1 x )(2x 1) - E 7 E 8 Pr
E
2 (A.16)
Tr Tr
(2x 1) 2 - E E P 2E15 3E16
13 14 r
Tr Tr
2
h mv xh vNH3 (1 x) h Hv 2O (A.17)
For the gas phase, Gibbs free energy equation is given below:
v v D2 2
2
D3 3
h ro Tr s ro D1 (Tr Tro ) 2 Tr Tro 3 Tr Tro 3
Tr D3 Pr
D1Tr ln T D 2 Tr (Tr Tro ) 2 (Tr Tro ) Tr ln P
2 2
ro ro
v
Gr P 4 P 3P T (A.18)
C1 Pr Pro C 2 r3 ro3 ro 4 r
Tr T T
ro ro
Pr 12Pro 11Pro Tr C 4 Pr 3 12Pro 3 11Pro 3 Tr
C 3 11
Tr Tro
11 12
Tro 3 Tr 11
Tro
11
Tro
12
132
h ro v Tro D 2 Tro D 3 2 Tro
2 3
s ro D1 1
v
Tr Tr
Tr Tr 2 T 3 T
r r
T 2
ln Pr
D Tro
D1 ln r D 2 Tr Tro 3 Tr P
T 2 T
v
Gr ro r ro
(A.19)
Tr C1 P 4Pro
3Pro
12Pro 11Pro
r Pr
Pr Pro C 2 4 3 4 C 3 12 11 12
Tr Tr Tro Tr Tro Tr Tro Tr Tro
C 4 Pr 11Pro
3 3 3
12Pro
12
Tro
12 12
3 Tr Tro Tr
h ro v T D T D
2
T
3
1
2 D1 ro2 2 1 ro2 3 2Tr ro2 D1
Tr T 2 Tr 3 Tr T
r r
v
Gr D Tro
2
C 4P 4P
D 2 3 1 2 12 Pr Pro C 2 5r 3 ro 2 (A.20)
Tr Tr 2 Tr Tr T Tro Tr
r
12Pr
3
3
12Pro C 4 12 P 12 P ro
C 3 13 11 2
r
Tro Tr 3 Tr Tro Tr
13 11 2
Tr
h ro
v
D 1 T ro
D2 2
2
T
r T ro2
3
D3 3
2Tr3 Tro
1 r 2 r
2
r
D T D T 2 D 3 T 2 T 2 C P P
ro 1 r ro
G r
v
2 4Pr 4Pro 12P 12P
Tr ro (A.21)
Tr Tr
C 2 3 3 C 3 11 11
r
pr T
Tr Tro r Tro
C 4 12Pr 12Pro
3 3
3 11
11
Tr Tro
D2 2
h ro D1Tro 2 Tr Tro 3 2Tr Tro
v 2 D3
3 3
1 r 2 r
2
r ro
D T D T 2 D 3 T 2 T 2 C P P
1 r ro
G r
v
h v RTB Tr
2 RTB 4Pr 4Pro 12P 12P (A.22)
Tr Tr r
11ro
pr 2
C
C
Tro
3 3 3 11
r T T ro rT
C 4 12Pr 12Pro
3 3
3 T 11 T 11
r ro
133
A.2.4 SPECIFIC ENTROPY AT LIQUID AND VAPOR PHASES
The molar entropy of the liquid and vapor phases is specified and simplified
from equation (A.23) to (A.33).
G
s R r (A.23)
T
r Pr
B2 B3 2 Tr
G rL s L
B1 ( 2T r ) 3T B
1 ln 1
ro 2 3 r Tro
(A.24)
Tr
B 2T T 3 3T 2 T 2 (A 2A T ) (P P )
B
2 r ro
ro 3 4 r r ro
2 r
s ro B1
L B2
2Tr B3 3Tr 2 B1 ln Tr 1
2 3 Tro
G L
r B3 2
2
s R
L R B 2 2Tr Tro 3T T
T 2 r ro
r
Pr A 2A T P P
3 4 r r ro
(A.25)
G E
s E R r
(A.26)
Tr Pr,x
E 2E E 2E
E 3 E 4 Pr 52 36 (2x 1) E 9 E10 Pr 112 12
Tr 3
G r
E
Tr T T
1 x
r r
Tr E 2 E
2 16
(2x 1) 2 3
15
Tr Tr
(A.27)
134
E 2E
E 3 E 4 Pr 52 36
Tr Tr
G r E E 2E
s E R R 1 x (2x 1) E 9 E10 Pr 112 12 3
(A.28)
Tr
Pr,x T r Tr
E 2 E
2 16
(2x 1) 2 3
15
Tr Tr
s mL xs aL (1 x )s Lw s E s m ix (A.30)
T
s V D1 D 2 Tr D 3 T 2 D1 1 ln r D 2 2Tr Tro
ro r
Tro
G V
P 3P 3P
r D3 2 2 r
3T T ln C r
ro (A.31)
Tr T
2 P
r ro 2
ro
4
T 4
ro
r
11P 11P 11P 3 11P 3
C ro C 4 r ro
r
3 12 12 3 T 12 12
Tr T T
ro
r ro
Tr
s ro D1 D 2 Tr D 3 Tr D1 1 ln
V 2
T ro
P
D3 2 r
D 2 2Tr Tro 2 3Tr Tro ln P
2
ro
G r V
s
v R 3P 3P 11P 11P (A.32)
Tr ro ro
C 2 4 C3
r r
Pr T
T 4 T 12 T 12
r ro
r ro
11Pr
3
11P 3
C4
ro
3 12 12
Tr T
ro
s mv xs aV (1 x )s Vw s m ix (A.33)
135
A.2.5 SPECIFIC VOLUME AT LIQUID AND VAPOR PHASES
The specific volume of the liquid and vapor phases is simplified from
equation (A.34) to (A.43).
RTB G r
v (A.34)
PB Pr Tr
G r
L
A1 A 3 Tr A 4 Tr A 2 Pr
2
(A.35)
Pr
G r L
v
L RTB
PB
Pr PB
1 3 r
RTB A A T A T 2 A P
4 r 2 r (A.36)
Tr
RTB G r E
v E (A.37)
PB Pr
Tr , x
G r
E
RTB G r
E
E
v
E RTB E 4 Tr 2x 1E 8 E10 Tr 2x 1 E14 1 x
2
PB Pr 2
PB
Tr
(A.39)
G Vr T C C C P2
r C1 32 113 411r (A.41)
Pr Pr Tr Tr Tr
G r V T C P
2
v
RTB
v RTB r C C 2 C3 4 r (A.42)
PB Pr PB Pr 1
Tr
3
Tr
11
Tr
11
Tr
v mv xv av (1 x ) v vw (A.43)
136
Table A.3 Coefficients for the equations for the pure components
The coefficient values for equations A6, A.12, A.13, A.14, A.18, A.24, and
A.31, are given in table A.3 and A.4.
Table A.4 Coefficients for the equations used for Gibbs excess energy function
Coefficients
E1 -41.733398
E2 0.02414
E3 6.702285
E4 -0.011475
E5 63.608967
E6 -62.490768
E7 1.761064
E8 0.008626
E9 0.387983
E10 0.004772
E11 -4.648107
E12 0.836376
E13 -3.553627
E14 0.000904
E15 21.361723
E16 -20.736547
137
Fig.A.3 Bubble and dew point temperature up to 100 bar
Fig.A.4 (a) Specific volume of saturated liquid and (b) Specific volume of saturated
vapor
138
Fig.A.5 Ammonia-water enthalpy concentration diagram
Figure A.3 is the plot for bubble and dew point temperature up to 100 bar
pressure. Figure A. 4(a) shows the changes in saturated liquid specific volume with
ammonia mass fraction at various pressures. The specific volume has been calculated
at bubble point temperature for the given pressure and ammonia mass fractions. The
trend increases with the increase in pressure. Similarly Fig A.4(b) is the saturated
vapor specific volume diagram. It is generated with the bubble point temperature and
vapor ammonia mass fraction.
139
Fig.A.6 Ammonia-water entropy concentration diagram
140
Fig.A.7 Ammonia-water exergy concentration diagram
The upper curve is the vapor curve, resulted from liquid concentration and
dew point temperature. The lower curve is the liquid enthalpy plot, resulted from the
bubble point temperature and liquid ammonia concentration. The auxiliary curve is
resulted from bubble point temperature and vapor ammonia concentration. The
curves are generated from 0.2 bar to 100 bar pressure.
141
Figure A.6 is an entropy-concentration plot as function of ammonia mass
fraction and pressure. The entropy values are decreasing with increase in pressure, in
liquid and vapor regions.
E = h - Tos (A.44)
142
if(((Tbp-Tdp)>=-1)&&((Tbp-Tdp)<=1))
df=1;
end
hm=(1-df)*hf+df*hg2;
sm=(1-df)*sf+df*sg2;
vm=(1-df)*vf+df*vg2;
Tdp=Tdp-273.15;
Tbp=Tbp-273.15;
hg1=0;
hg2=0;
case 3
hm=(1-df)*hf+df*hg2;
sm=(1-df)*sf+df*sg2;
vm=(1-df)*vf+df*vg2;
Tdp=Tdp-273.15;
Tbp=Tbp-273.15;
case 4
%AMMONIA-WATER LIQUID MIXTURE
hm=(1-df)*hf+df*hg2;
sm=(1-df)*sf+df*sg2;
vm=(1-df)*vf+df*vg2;
Tdp=Tdp-273.15;
Tbp=Tbp-273.15;
case 5
hm=(1-df)*hf+df*hg2;
sm=(1-df)*sf+df*sg2;
vm=(1-df)*vf+df*vg2;
Tdp=Tdp-273.15;
Tbp=Tbp-273.15;
end
From Patek and Klomfar (1994) equations, the bubble and dew point
temperatures have been calculated and tabulated in Table A5 and Table A6
respectively. The specific enthalpy, specific entropy, specific volume and specific
exergy values are tabulated using Xu and Goswami (1999) mathematical relations
(Table A7 to A12).
143
Table A.5 Bubble point temperature, ºC
Pressure, bar
x
0.2 0.4 0.6 0.8 1.0 2.0 4.0 6.0 8.0 10 15 20 30 40 50 60 70 80 90 100
0 60.50 76.10 86.02 93.48 99.53 120.00 143.47 158.85 170.59 180.06 198.96 213.14 234.96 251.68 265.39 277.10 287.38 296.57 304.90 312.53
0.1 29.59 45.25 55.22 62.71 68.78 89.31 112.81 128.18 139.90 149.32 168.17 182.26 203.95 220.55 234.15 245.77 255.96 265.06 273.31 280.87
0.2 10.25 24.94 34.34 41.42 47.17 66.70 89.15 103.87 115.13 124.16 142.32 155.87 176.80 192.83 205.98 217.21 227.07 235.89 243.87 251.20
0.3 -6.71 7.00 15.83 22.50 27.94 46.44 67.82 81.89 92.66 101.30 118.74 131.76 151.90 167.35 180.04 190.89 200.42 208.93 216.66 223.74
0.4 -22.51 -9.54 -1.17 5.17 10.34 28.01 48.49 62.00 72.36 80.67 97.49 110.04 129.51 144.45 156.73 167.24 176.47 184.72 192.22 199.09
0.5 -36.09 -23.70 -15.68 -9.59 -4.63 12.35 32.08 45.13 55.14 63.17 79.45 91.61 110.48 124.98 136.90 147.11 156.07 164.10 171.38 178.06
0.6 -46.43 -34.49 -26.75 -20.88 -16.08 0.32 19.41 32.04 41.74 49.53 65.31 77.12 95.45 109.54 121.14 131.07 139.80 147.61 154.70 161.21
0.7 -53.26 -41.67 -34.17 -28.48 -23.84 -7.93 10.56 22.80 32.21 39.78 55.10 66.58 84.40 98.11 109.40 119.06 127.56 135.17 142.08 148.42
0.8 -57.14 -45.86 -38.57 -33.04 -28.53 -13.10 4.83 16.71 25.84 33.19 48.07 59.23 76.55 89.89 100.88 110.29 118.57 125.99 132.72 138.90
0.9 -59.25 -48.22 -41.12 -35.74 -31.35 -16.37 1.03 12.55 21.41 28.54 42.99 53.82 70.67 83.64 94.33 103.50 111.56 118.78 125.34 131.37
1 -60.78 -49.96 -43.03 -37.79 -33.52 -18.96 -2.08 9.09 17.68 24.60 38.62 49.14 65.50 78.11 88.51 97.43 105.28 112.32 118.71 124.58
144
Table A.6 Dew point temperature, ºC
Pressure, bar
x
0.2 0.4 0.6 0.8 1.0 2.0 4.0 6.0 8.0 10 15 20 30 40 50 60 70 80 90 100
0 60.50 76.10 86.02 93.48 99.53 120.00 143.47 158.85 170.59 180.06 198.96 213.14 234.96 251.68 265.39 277.10 287.38 296.57 304.90 312.53
0.1 60.99 75.79 85.26 92.41 98.22 117.93 140.48 155.17 166.31 175.40 192.95 206.24 226.25 241.38 253.68 265.10 273.19 281.26 288.53 295.17
0.2 57.77 72.39 81.75 88.81 94.54 114.00 136.25 150.75 161.76 170.73 188.06 201.19 220.96 235.91 248.07 258.37 267.35 275.33 282.53 289.09
0.3 54.69 69.01 78.16 85.07 90.69 109.74 131.55 145.77 156.57 165.38 182.40 195.30 214.74 229.45 241.41 251.55 260.39 268.24 275.33 281.80
0.4 51.53 65.47 74.38 81.10 86.56 105.09 126.32 140.18 150.70 159.29 175.90 188.50 207.48 221.86 233.56 243.48 252.13 259.82 266.76 273.09
0.5 48.01 61.57 70.21 76.72 82.01 99.94 120.47 133.86 144.04 152.35 168.42 180.63 199.02 212.96 224.30 233.92 242.32 249.78 256.52 262.67
0.6 43.76 57.03 65.43 71.74 76.84 94.11 113.82 126.65 136.41 144.36 159.75 171.43 189.05 202.40 213.27 222.50 230.54 237.70 244.16 250.06
0.7 38.27 51.44 59.65 65.77 70.71 87.27 106.02 118.17 127.39 134.90 149.41 160.41 177.00 189.57 199.80 208.48 216.06 222.80 228.88 234.44
0.8 30.74 44.03 52.14 58.10 62.87 78.65 96.22 107.51 116.03 122.96 136.29 146.39 161.58 173.08 182.43 190.37 197.29 203.45 209.01 214.09
0.9 19.26 32.75 40.72 46.46 50.99 65.66 81.57 91.62 99.14 105.23 116.90 125.69 131.87 148.84 156.93 163.80 169.78 175.11 179.91 184.30
1 -60.78 -49.96 -43.03 -37.79 -33.52 -18.96 -2.08 9.09 17.68 24.60 38.62 49.14 65.50 78.11 88.51 97.43 105.28 112.32 118.71 124.58
145
A.4.2 SPECIFIC ENTHALPY VALUES
Pressure, bar
x
0.2 0.4 0.6 0.8 1.0 2.0 4.0 6.0 8.0 10 15 20 30 40 50 60 70 80 90 100
0 252.4 317.87 359.54 390.93 416.44 503.1 603.6 670.1 721.4 763.78 847.17 911.92 1012.1 1090.4 1155.6 1212.1 1262.3 1307.6 1349.1 1387.5
0.1 55.87 121.49 163.19 194.56 220.03 306.6 406.9 473.6 525.2 567.94 652.36 718.27 820.96 901.73 969.48 1028.5 1081.1 1128.8 1172.6 1213.3
0.2 -91.72 -28.97 10.89 40.88 65.25 148.1 244.4 308.6 358.4 399.83 481.88 546.23 647.03 726.78 793.99 850.72 905.28 953.10 997.14 1038.1
0.3 -221.5 -160.7 -122.2 -93.23 -69.72 10.13 102.8 164.6 212.6 252.52 331.76 394.06 491.92 569.61 635.27 692.80 744.39 791.42 834.81 875.22
0.4 -332.5 -272.1 -234.0 -205.4 -182.3 -104.1 -13.80 46.24 92.76 131.40 208.19 268.56 363.48 438.95 502.82 558.87 609.19 655.12 697.54 737.08
0.5 -414.7 -353.7 -315.5 -286.9 -263.9 -186.4 -97.53 -38.71 6.75 44.46 119.28 178.05 270.42 343.88 406.09 460.70 509.78 554.59 596.01 634.65
0.6 -458.5 -397.1 -358.7 -330.2 -307.3 -230.3 -142.5 -84.67 -40.04 -3.07 70.19 127.68 217.99 289.80 350.63 404.05 452.08 495.95 536.51 574.36
0.7 -459.6 -398.9 -361.1 -332.9 -310.3 -234.5 -148.2 -91.39 -47.57 -11.27 60.64 117.07 205.75 276.29 336.07 388.59 435.83 478.99 518.92 556.18
0.8 -421.6 -363.2 -326.8 -299.7 -277.8 -204.3 -120.3 -64.77 -21.86 13.71 84.31 139.82 227.16 296.73 355.75 407.64 454.32 497.01 536.50 573.36
0.9 -355.1 -300.9 -266.8 -241.3 -220.6 -150.7 -69.87 -16.00 25.79 60.56 129.81 184.42 270.61 339.43 397.89 449.33 495.65 538.01 577.21 613.81
1 -274.0 -226.0 -195.2 -171.9 -152.9 -87.7 -10.99 40.80 81.30 115.15 182.93 236.66 321.80 390.00 448.03 499.15 545.20 587.34 626.35 662.78
146
Table A.8 Saturated vapor enthalpy of ammonia-water mixture, kJ/kg
Pressure, bar
x
0.2 0.4 0.6 0.8 1.0 2.0 4.0 6.0 8.0 10 15 20 30 40 50 60 70 80 90 100
0 2612.2 2639.0 2655.6 2667.7 2677.2 2708.1 2739.8 2758.3 2771.1 2780.6 2796.9 2807.1 2818.9 2824.8 2827.7 2828.6 2828.4 2827.3 2825.6 2823.5
0.1 1548.1 1634.1 1690.4 1732.5 1766.3 1876.0 1989.6 2056.1 2102.8 2138.3 2200.9 2243.2 2298.7 2334.4 2359.6 2378.2 2392.4 2403.5 2412.3 2419.4
0.2 1359.8 1406.5 1439.9 1466.4 1488.7 1567.3 1658.9 1717.4 1760.4 1794.5 1856.9 1900.9 1961.1 2001.5 2031.0 2053.5 2071.1 2085.3 2096.8 2106.3
0.3 1296.3 1327.5 1349.3 1366.6 1381.2 1433.8 1498.3 1541.6 1574.5 1601.1 1651.2 1687.6 1738.8 1774.0 1799.9 1819.8 1835.5 1848.1 1858.3 1866.7
0.4 1256.9 1282.5 1299.7 1312.9 1323.9 1362.7 1409.6 1441.2 1465.5 1485.2 1522.9 1550.5 1589.5 1616.3 1635.9 1650.6 1662.0 1670.7 1677.5 1682.7
0.5 1227.0 1250.0 1265.1 1276.5 1285.8 1317.6 1354.5 1378.6 1396.9 1411.7 1439.5 1459.6 1487.3 1505.6 1518.1 1526.9 1532.9 1536.8 1539.1 1540.1
0.6 1204.9 1226.5 1240.3 1250.7 1259.1 1287.1 1318.2 1337.7 1352.1 1363.5 1384.2 1398.5 1416.8 1427.4 1433.2 1436.0 1436.4 1435.0 1432.3 1428.5
0.7 1190.4 1210.9 1224.0 1233.7 1241.5 1267.1 1294.5 1311.1 1323.0 1332.0 1347.7 1357.7 1368.5 1372.5 1372.3 1369.4 1364.4 1357.8 1350.1 1341.2
0.8 1182.2 1201.8 1214.3 1223.5 1230.8 1254.7 1279.6 1294.2 1304.3 1311.7 1323.8 1330.4 1335.3 1333.7 1328.3 1320.3 1310.3 1298.9 1286.2 1272.5
0.9 1177.7 1196.7 1208.6 1217.4 1224.4 1246.9 1269.8 1282.9 1291.6 1297.7 1306.9 1310.9 1310.7 1304.3 1294.2 1281.4 1266.8 1250.6 1233.1 1214.7
1 1174.6 1192.9 1204.4 1212.8 1219.5 1240.7 1261.9 1273.5 1281.0 1286.0 1292.5 1294.0 1289.1 1278.0 1263.1 1245.5 1225.9 1204.7 1182.2 1158.6
147
A.4.3 SPECIFIC ENTROPY VALUES
Pressure, bar
x
0.2 0.4 0.6 0.8 1.0 2.0 4.0 6.0 8.0 10 15 20 30 40 50 60 70 80 90 100
0 0.83 1.03 1.14 1.23 1.30 1.52 1.77 1.93 2.05 2.14 2.32 2.45 2.65 2.80 2.92 3.02 3.11 3.19 3.26 3.32
0.1 0.46 0.68 0.80 0.90 0.97 1.22 1.49 1.66 1.78 1.89 2.08 2.23 2.45 2.61 2.74 2.86 2.96 3.04 3.12 3.19
0.2 0.14 0.35 0.48 0.58 0.66 0.91 1.18 1.36 1.49 1.59 1.79 1.95 2.17 2.35 2.49 2.61 2.71 2.81 2.89 2.97
0.3 -0.19 0.02 0.15 0.25 0.33 0.59 0.87 1.05 1.18 1.29 1.50 1.65 1.89 2.06 2.21 2.33 2.44 2.54 2.63 2.71
0.4 -0.54 -0.30 -0.16 -0.06 0.01 0.28 0.57 0.76 0.89 1.00 1.21 1.37 1.61 1.79 1.94 2.07 2.18 2.28 2.37 2.45
0.5 -0.85 -0.60 -0.45 -0.34 -0.25 0.02 0.32 0.50 0.64 0.76 0.97 1.14 1.38 1.57 1.72 1.85 1.96 2.06 2.15 2.23
0.6 -1.09 -0.82 -0.66 -0.55 -0.46 -0.17 0.13 0.32 0.47 0.58 0.80 0.97 1.21 1.40 1.56 1.69 1.80 1.90 1.99 2.08
0.7 -1.21 -0.94 -0.78 -0.67 -0.57 -0.28 0.02 0.22 0.36 0.48 0.70 0.87 1.12 1.31 1.46 1.6 1.71 1.81 0.91 1.99
0.8 -1.23 -0.96 -0.81 -0.69 -0.60 -0.29 -0.005 0.18 0.33 0.45 0.67 0.84 1.09 1.28 1.43 1.56 1.68 1.78 1.88 1.96
0.9 -1.17 -0.92 -0.77 -0.66 -0.58 -0.30 0.0003 0.19 0.33 0.44 0.67 0.83 1.08 1.28 1.43 1.56 1.68 1.78 1.88 1.96
1 -1.11 0.89 -0.75 -0.65 -0.57 -0.31 -0.02 0.16 0.30 0.41 0.63 0.79 1.05 1.24 1.40 1.53 1.65 1.75 1.85 1.93
148
Table A.10 Saturated vapor entropy of ammonia-water mixture, kJ/kg-K
Pressure, bar
x
0.2 0.4 0.6 0.8 1.0 2.0 4.0 6.0 8.0 10 15 20 30 40 50 60 70 80 90 100
0 8.18 7.94 7.79 7.69 7.62 7.39 7.17 7.04 6.95 6.89 6.77 6.69 6.57 6.48 6.41 6.35 6.29 6.24 6.19 6.15
0.1 7.98 7.75 7.61 7.51 7.44 7.22 7.01 6.89 6.80 6.74 6.62 6.54 6.41 6.32 6.24 6.16 6.09 6.03 5.97 5.90
0.2 7.78 7.54 7.40 7.31 7.23 7.01 6.80 6.68 6.59 6.53 6.41 6.32 6.17 6.06 5.95 5.86 5.76 5.67 5.58 5.49
0.3 7.55 7.31 7.17 7.08 7.00 6.78 6.57 6.44 6.36 6.29 6.15 6.05 5.88 5.73 5.58 5.45 5.31 5.18 5.04 4.90
0.4 7.30 7.06 6.92 6.83 6.76 6.53 6.32 6.19 6.09 6.02 5.87 5.74 5.52 5.32 5.12 4.93 4.73 4.53 4.34 4.14
0.5 7.05 6.81 6.67 6.58 6.50 6.28 6.06 5.92 5.82 5.74 5.56 5.41 5.13 4.87 4.60 4.34 4.07 3.80 3.52 3.25
0.6 6.80 6.56 6.42 6.33 6.25 6.03 5.80 5.66 5.55 5.45 5.26 5.08 4.75 4.42 4.10 3.77 3.44 3.10 2.76 2.42
0.7 6.56 6.32 6.18 6.09 6.01 5.78 5.55 5.40 5.29 5.19 4.98 4.79 4.43 4.07 3.71 3.35 2.98 2.61 2.24 1.86
0.8 6.33 6.09 5.95 5.85 5.77 5.54 5.30 5.15 5.03 4.94 4.72 4.54 4.18 3.83 3.49 3.14 2.78 2.43 2.07 1.71
0.9 6.08 5.83 5.69 5.59 5.52 5.28 5.04 4.89 4.77 4.68 4.48 4.31 4.00 3.71 3.41 3.12 2.83 2.54 2.25 1.95
1 5.77 5.53 5.38 5.28 5.20 4.96 4.71 4.57 4.46 4.37 4.20 4.06 3.83 3.62 3.43 3.25 3.06 2.89 2.71 2.54
149
A.4.4 SPECIFIC EXERGY VALUES
Table A.11 Specific exergy for saturated liquid ammonia-water mixture, kJ/kg
Pressure, bar
x
0.2 0.4 0.6 0.8 1.0 2.0 4.0 6.0 8.0 10 15 20 30 40 50 60 70 80 90 100
0 5.06 10.93 19.82 24.39 29.04 50.14 76.14 94.96 110.5 126.06 155.81 181.8 222.4 256 285.44 312.14 335.52 356.95 377.62 398.14
0.1 -81.21 -81.15 -75.21 -73.64 -69.03 -56.96 -37.12 -21.08 -5.24 4.72 32.52 53.73 90.86 123.95 152.96 176.22 199.02 222.88 242.84 262.68
0.2 -133.4 -133.2 -132.1 -131.9 -131.0 -123.0 -107.2 -96.68 -85.62 -73.99 -51.54 -34.87 0.37 26.48 51.97 72.94 97.7 115.72 135.92 153.04
0.3 -164.8 -166.6 -166.9 -167.7 -168.0 -165.6 -156.4 -148.3 -139.0 -131.9 -115.2 -97.64 -71.3 -44.27 -23.31 -1.54 17.27 34.5 51.07 67.64
0.4 -171.5 -182.7 -186.3 -187.5 -185.2 -187.5 -183.6 -180.2 -172.4 -166.6 -152.3 -139.7 -116.3 -94.47 -75.3 -57.99 -40.45 -24.32 -8.72 6.98
0.5 -161.4 -174.9 -181.4 -185.5 -189.4 -192.3 -192.8 -187.7 -183.9 -182.0 -169.7 -161.6 -140.8 -123.9 -106.4 -90.6 -74.3 -59.29 -44.69 -29.89
0.6 -133.6 -152.7 -162.0 -166.3 -170.2 -179.6 -181.2 -180.0 -180.1 -175.9 -168.2 -161.3 -142.5 -127.4 -114.2 -99.57 -84.32 -70.25 -56.51 -45.48
0.7 -99.02 -118.7 -128.6 -133.2 -140.4 -151.0 -154.1 -156.9 -154.8 -154.3 -147.9 -142.1 -128.0 -114.0 -99.01 -88.21 -73.75 -60.39 247.74 -36.84
0.8 -55.06 -77.12 -85.42 -94.08 -99 -117.8 -118.8 -118.4 -120.2 -120.3 -115.3 -110.5 -97.66 -84.71 -70.39 -57.24 -46.32 -33.43 -23.74 -10.72
0.9 -6.44 -26.74 -37.34 -44.62 -47.76 -61.3 -69.95 -72.62 -72.55 -70.56 -69.85 -62.92 -51.23 -42.01 -28.25 -15.55 -4.99 7.57 16.97 29.73
1 56.78 -491.2 28.3 21.8 16.96 4.68 -5.03 -6.88 -8.1 -7.03 -4.81 1.24 8.9 20.48 30.83 43.21 53.5 65.84 75.05 87.64
150
Table A.12 Specific exergy for saturated vapor ammonia-water mixture, kJ/kg
Pressure, bar
x
0.2 0.4 0.6 0.8 1.0 2.0 4.0 6.0 8.0 10 15 20 30 40 50 60 70 80 90 100
0 174.56 272.88 334.18 376.0 406.44 505.88 603.14 660.38 700 727.38 779.44 813.8 861.04 893.76 917.52 963.3 953.98 967.78 980.98 990.8
0.1 -829.9 -675.4 -577.3 -505.4 -450.8 -275.5 -99.38 2.88 76.4 129.78 228.14 294.28 388.52 451.04 500.08 542.52 577.58 606.56 633.24 661.2
0.2 -958.6 -840.4 -765.3 -711.9 -665.8 -521.6 -367.5 -273.2 -203.4 -151.4 -53.28 17.54 122.44 195.62 257.9 307.22 354.62 395.64 433.96 470.28
0.3 -953.6 -850.8 -787.3 -743.2 -704.8 -586.6 -459.5 -377.5 -320.3 -273.3 -181.5 -115.3 -13.44 66.46 137.06 195.7 253.12 304.46 356.38 406.5
0.4 -918.5 -821.3 -762.4 -722.4 -690.5 -583.2 -473.5 -403.4 -349.3 -308.7 -226.3 -160.0 -55.46 30.94 110.14 181.46 252.46 320.76 384.18 448.98
0.5 -873.9 -779.3 -722.5 -684.3 -651.2 -553.8 -451.3 -385.5 -337.4 -298.8 -217.3 -152.5 -41.44 54.34 147.3 233.58 320.04 404.4 490.14 571.6
0.6 -821.5 -728.3 -672.8 -635.6 -603.4 -509.8 -410.2 -348.9 -301.8 -260.6 -183.2 -115.3 1.3 110.24 211.4 312.54 411.28 511.2 609.82 707.34
0.7 -764.4 -672.4 -617.6 -581.1 -549.4 -455.3 -359.4 -298.1 -253.4 -214.6 -136.3 -69.71 48.36 159.36 266.72 371.1 476.36 580.02 682.58 786.92
0.8 -704.1 -613.0 -558.8 -519.8 -488.6 -396.2 -299.8 -240.5 -194.6 -160.4 -82.76 -22.52 89.66 192.36 288.28 384.58 481.86 574.76 669.34 762.92
0.9 -634.1 -540.6 -487.0 -448.4 -420.5 -326.5 -232.1 -174.3 -129.8 -96.94 -28.14 26.52 118.7 198.72 278.02 351.64 423.46 493.68 562.6 633.6
1 -544.8 -455.0 -398.8 -360.6 -330.1 -237.3 -141.6 -88.36 -48.08 -16.26 40.9 84.12 147.76 199.24 246.96 277 314.02 343.48 374.62 401.68
151
Appendix B
The process flow charts for three Kalina cycle systems (KCSs) are developed and
depicted in Fig.B.1, B.2 and B.3 respectively for low, medium and high temperature
heat recoveries.
Start
Separator concentrations (inlet and liquid outlet) from temperature and pressure
Economic evaluation
Stop
152
Start
Economic evaluation
Stop
153
Start
Economic evaluation
Stop
154