Wps Magi Tig Exemple PDF
Wps Magi Tig Exemple PDF
Wps Magi Tig Exemple PDF
(WPS)
(SEE QW – 201.1, SECTION IX, ASME BOILER
AND PRESSURE VESSEL CODE
SHEET 1 OF 2
Company Name DCMS ENGINEERING CO.
Welding Procedure Specification No DCMS/WPS/099 Rev-0 Date : 19/04/2012
Supporting PQR no. (S) DCMS/PQR/099 Rev - 0 Date : 7.05.2012
Welding Process (es) GTAW Type (s) Manual
(Automatic, Manual, Machine or semi – Automatic)
SHEET 2 OF 2
TECHNIQUE (QW-410)
String or weave bead Root (stringer) & Final (weaving).
Orifice or Gas Cup Size ceramic nozzle of ¼”
Initial and Inter pass (Cleaning Brushing, Grinding etc.)Degreasing with acetone, wire brushing, if required grinding of all pass.
Method of Back Gouging _____NA ______________
Oscillation 2.5 times of size of filler wire_____________
Contact Tube to Work Distance _____NA______________
Single Pass (per side) __ Multiple____________
Multiple or Single Electrode __Single_____________
Travel Speed (Range) 40-65 mm/min.__
Peening Not Allowed
Other _NA__________________
JOINTS (QW-402)
Plates ASTM - A -240 Gr. 304L to Plate ASTM – A - 240 Gr. 304L
Groove Design of Test Coupon
Specimen Width Thickness Area Ultimate Ultimate Unit Type of Failure and
No. mm mm mm2 Total Load N Stress N/mm2 Location
T-1 19 5.90 112.10 70400 628.01 weld metal
T-2 18.80 5.94 99.75 62400 625.56 weld metal
NA
Comments ________________________________________NA__________________________________
Result – Satisfactory Yes _________No. _________ Penetration into Parent Metal Yes ______ No. ___
Macro – Results_________________ NA ___________________________________________________
Other Tests
Type of Test ___________________________________________________________________________
Deposit Analysis _________ _______________ NA __________________________________________
Other _________________________________________________________________________________
Details of record of tests are illustrative only and may be modified to confirm to the type and number of tests
required by the Code.
Page 3 of 3
Numbers
Electrode Gas Backing Current
of Runs / Speed
Th 2% Filler Wire Shielding Gas Volts Amp
Weld mm/min
(Tungsten) ltrs / min Ltrs./min
Passes
st
1 1.6 mm dia
2.4 mm 14 12 11 72 48.8
(Root) ER 308-L
rd 1.6 mm dia
3 pass 2.4mm 14 12 87 53.04
ER – 308-L 12
4th pass
2.4mm 1.6 mm dia 14 12 87 49.4
12
ER – 308-L