SOLVENT FREE POLYURETHANE SELF LEVEL FLOORING SYSTEM (2K & 3K)
APPLICATION DATA
Substrate Quality Concrete substrates must
be sound and of sufficient compressive strength
(minimum 25 N/mm2) with a minimum pull off
strength of 1.5 N/mm2. the substrate must be
clean, dry and free of all contaminants such as
MIPROTHANE-SL is a two part-solvent based dirt, oil, grease, coatings and surface
coloured self-smoothing polyurethane resin with treatments, etc. if in doubt apply a test area
tough-elastic properties. first.
Substrate Preparation Concrete substrates
Uses Areas must be prepared mechanically using abrasive
- Smooth wearing course with crack- blast cleaning or scarifying equipment to
bridging properties for industrial floors in remove cement laitance and achieve an open
production and storage facilities, work textured surface. Weak concrete must be
shops etc. removed and surface defects such as voids
- Broadcast wearing course with crack- must be fully exposed. Repairs to the substrate,
bridging properties for wet working areas filling of blovoids and surface leveling must be
(food and beverage industry etc.), car carried out by using MIPRO-E epoxy repair
park decks and loading ramps etc. mortar the concrete or screed substrate has to
- Seal coat for broadcast systems be primed leveled in order to achieve an even
- Can be subjected to medium heavy surface. High spots must be removed by e.g.
mechanical and chemical stress grinding. All dust; loose and friable material
must be completely removed from all surfaces
Characteristics / Advantages before application of the product preferably by
- Flexible and tough-elastic–crack- brush and /or vacuum.
bridging–Good chemical and mechanical
resistance resistant surface possible – Application Conditions: Min. +100C min.
Liquid proof – Easy to apply – Easy to Max. +300C max.
clean – Economical
Substrate Moisture Content < 4% phw
Product Data moisture content. R.H. 70% max.
Form/ Appearance Dew Point Beware of condensation The
Resin – part a: colored, liquid substrate and uncured floor must be at least
Hardener – part B: clear, liquid 30C above the dew point to reduce the risk of
Filler – Part - C condensation or blooming on the floor finish.
Colors: Available in range of colors.
CHEMIPROTECT ENGINEERS
Plot No. 2114, Phase-3, GIDC Estate, Vatva, Ahmedabad-382 445
Tel: 079-25891689 Fax: 079-25830002
E-mail: chemiprotect@gmail.com chemiprotect@gmail.com
MIPROTHANE-SL
SOLVENT FREE POLYURETHANE SELF LEVEL FLOORING SYSTEM (2K & 3K)
Application Instructions
Mixing: Mix Part A & B by weight as mention
on packing
Packaging
2K SL
Part A: 25 kg containers
Part B: 5 kg containers
3K SL
Part A: 5 kg containers
Part B: 2 kg containers
Part C 14 kgs Bag
CHEMIPROTECT ENGINEERS
Plot No. 2114, Phase-3, GIDC Estate, Vatva, Ahmedabad-382 445
Tel: 079-25891689 Fax: 079-25830002
E-mail: chemiprotect@gmail.com chemiprotect@gmail.com