38/52 Bosch Rexroth AG A7VO Baureihe 63 | RE 92203/06.

09

HD.G with remotely adjustable pressure control


Initial position: Vg min in pressureless condition
The pressure control overrides the HD function. Characteristic
In order to obtain a remote adjustment of the pressure control

$pmax 10 bar
level a separate pilot pressure relief (item 2) valve must be con- 350
nected to port X3. This relief valve is not included in the supply of

Operating pressure p [bar]


the DRG control.

Setting range
Setting range of the pressure control _________ 50 to 350 bar
The spring force on the pressure compensator spool causes a
differential pressure between pump output pressure and pres-
sure at X3 (as soon as the relief valve opens and the pressure
control function takes place). Standard setting of this differential 50
pressure 25 bar.
As long as the the pressure is below the set pressure of the q Vmin q Vmax
relief valve, the pressures on both sides of the pressure com-
pensator spool are equal and the additional spring force keeps Flow
this spool in a shifted position (Spool in equilibrium). Schematic
As soon as the set pressure of the relief valve is reached, this Hydraulic control, pilot pressure dependent with integrated
valve will start to open and the pilot flow will result in a differential pressure control
pressure over the compensator spool, which causes this spool to
shift and brings the pump to a smaller displacement Vg min. MB B R1 R2

Upon reaching the set pressure control level (set pressure at


pilot relief valve plus differential pressure at pressure control X2
compensator) the pump will go over to the pressure control
mode.
The differential pressure at the pressure compensator spool Vgmax Vgmin
(item 1) is normally set at 25 bar, which results in a pilot flow at 6
X3 of approx. 2 L/min.
In case another setting (range 14 to 50 bar) is required, please
M
state in clear text when ordering.
As a seperate pilot relief valve we recommend: 1
DBD 6 (hydraulic) see RE 25402
DBETR-SO 437 with dampened spool
(electric) see RE 29166 U S X1 X3
The max. line lenght should not exceed 2 m.
2
Note
– The beginning of control and the pressure control characte-
ristic are influenced by housing pressure. An increase in Sub assemblies
housing pressure results in a higher beginning of control (see 1 Integrated pressure control compensator
page 7) and thus a parallel shift of the control characteristic. 2 Separate pressure relief valve (not in scope of supply)
– Standby operation see page 6. 6 HD-pilot valve

Ports for
X1 Pilot pressure
X2 External control pressure
X3 Separate pressure relief valve
(for HDG)
M Measuring of pressure on control piston (plugged)

Dimensions see page 39