AEROSPACE AMS2630 REV.

C
MATERIAL
Issued 1960-06
SPECIFICATION Revised 2010-01

Superseding AMS2630B
Inspection, Ultrasonic
Product Over 0.5 Inch (12.7 mm) Thick

RATIONALE

AMS2630C revises requirements for qualification (3.1.1), transducers (3.2.2.1), shear wave references (3.2.4.4), special
references (3.2.4.6), and gating (3.4.9.1.2), and is a Five Year Review and update of this specification.

1. SCOPE

1.1 Purpose

This specification covers procedures for ultrasonic inspection, by pulse-echo procedures, of flat, rectangular, round,
cylindrical, and contoured products having a thickness or cross-sectional dimension greater than 0.50 inch (12.7 mm),
using either contact or immersion methods, and using the longitudinal-wave or shear-wave modes or combinations of the
two, as necessary. This specification may apply to testing finished machined parts provided the parts can meet the basic
testability requirements, such as size, contour, metallurgical structure, and thickness.

1.2 Parts with section thickness both over 0.50 inch (12.7 mm) and 0.5 inch (12.7 mm) and under may be tested using
this procedure and AMS2632, as applicable.

1.3 Application

This procedure has been used typically for locating and defining internal defects such as cracks, voids, laminations, and
other structural discontinuities which may or may not be exposed to the surface, but usage is not limited to such
applications.

2. APPLICABLE DOCUMENTS

The issue of the following documents in effect on the date of the purchase order forms a part of this specification to the
extent specified herein. The supplier may work to a subsequent revision of a document unless a specific document issue
is specified. When the referenced document has been cancelled and no superseding document has been specified, the
last published issue of that document shall apply.

2.1 SAE Publications

Available from SAE International, 400 Commonwealth Drive, Warrendale, PA 15096-0001, Tel: 877-606-7323 (inside
USA and Canada) or 724-776-4970 (outside USA), www.sae.org.

AMS2632 Inspection, Ultrasonic, of Thin Materials, 0.5 Inch (12.7 mm) and Under Cross-Sectional Thickness

SAE J300 Crankcase Oil Viscosity Classification

2.2 ASTM Publications


__________________________________________________________________________________________________________________________________________
SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is
entirely voluntary, and its applicability and suitability for any particular use, including any patent infringement arising therefrom, is the sole responsibility of the user.”
SAE reviews each technical report at least every five years at which time it may be reaffirmed, revised, or cancelled. SAE invites your written comments and suggestions.
Copyright © 2010 SAE International
All rights reserved. No part of this publication may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical,
photocopying, recording, or otherwise, without the prior written permission of SAE.
TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) SAE values your input. To provide feedback
Tel: +1 724-776-4970 (outside USA) on this Technical Report, please visit
Fax: 724-776-0790 http://www.sae.org/technical/standards/AMS2630C
Email: CustomerService@sae.org
SAE WEB ADDRESS: http://www.sae.org
SAE AMS2630C Page 2 of 21

Available from ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959, Tel:
610-832-9585, www.astm.org.

ASTM E 127 Fabricating and Checking Aluminum Alloy Ultrasonic Standard Reference Blocks
ASTM E 317 Evaluating Performance Characteristics of Ultrasonic PulseEcho Testing Systems Without the Use of
Electronic Measurement Instruments
ASTM E 428 Fabrication and Control of Steel Reference Blocks Used in Ultrasonic Inspection
ASTM E 1065 Evaluating Characteristics of Ultrasonic Search Units

2.3 Aerospace Industries Association Publications

Available from the Aerospace Industries Association, 1000 Wilson Boulevard, Suite 1700, Arlington, VA 22209-3928,
www.aia-aerospace.org

NAS-410 Nondestructive Testing Personnel Qualification and Certification

2.4 ANSI Publications

Available from American National Standards Institute, 25 West 43rd Street, New York, NY 10036, Tel: 212-642-4900,
www.ansi.org.

ANSI B46.1 Surface Texture

2.5 ASNT Publications

Available from American Society for Nondestructive Testing, P.O. Box 28518, 1711 Arlingate Lane, Columbus, OH
43228-0518, 800-222-2768 (inside U.S. and Canada), 614-274-6003 (outside USA), www.asnt.org.

SNT-TC-1A Recommended Practice, Personnel Qualification and Certification in Nondestructive Testing

2.6 ATA Publications

Available from Air Transport Association of America, 1301 Pennsylvania Avenue, NW - Suite 1100, Washington, DC
20004-1707, Tel: 202-626-4000, www.airlines.org.

ATA-105 Guidelines for Training and Qualifying Personnel in Nondestructive Testing

3. TECHNICAL REQUIREMENTS

3.1 Qualification

3.1.1 Personnel

Shall be qualified and certified in accordance with NAS-410. Alternate procedures, such as ASNT-TC-1A or ATA-105,
may be used if specified on the drawing or purchase order. It is the supplier's responsibility to ensure that personnel are
certified and function within the limits of the applicable specification or procedure.

3.1.2 Facilities

Shall be subject to survey and approval by purchaser of the inspected product. Ultrasonic test facility equipment shall
include, but not be limited to, the basic ultrasonic test instrument, search units (transducers), appropriate ultrasonic
references, couplant materials, fixtures, reference specifications, and immersion tanks where applicable. Reference
specifications and documentation necessary to verify the qualification of equipment and test personnel shall be available
upon request.
SAE AMS2630C Page 3 of 21

3.2 Ultrasonic Test System

3.2.1 Basic Ultrasonic Test Instrument

Shall be capable of producing, receiving, amplifying, and displaying on a cathode ray tube (CRT) high frequency signals
at specific frequencies as required by the test and shall be of a pulse-reflection (echo), pulse-transmission type. The
instrument, if required by the test, shall be capable of being adapted with electronic circuitry, such as flaw gates and
distance amplitude corrections. A minimum of a 2:1 signal-to-noise ratio is required unless otherwise agreed upon by
purchaser and vendor.

3.2.1.1 Instrument Linearity

The instrument performance characteristics shall be evaluated in accordance with ASTM E 317 except as follows:

3.2.1.1.1 The calibration block used for evaluating vertical linearity shall be as shown in Figure 1.

3.2.1.1.2 The vertical linearity plot and the tolerance limits shall be as shown in either Figure 2 or Figure 2A.

3.2.1.1.3 The horizontal linearity check shall be made by plotting signal displacement against known thickness in the
range of 1.0 to 5 inches (25.4 to 127 mm) in 1.0 inch (25.4 mm) increments; the allowable difference in
thickness between that indicated by the signal displacement and the actual measured thickness shall be
within ±3% of the measured thickness of the respective block. Substitute performance checks are permissible
when acceptable to purchaser.

3.2.1.2 Instrument Sensitivity

Instrument sensitivity or gain controls shall function so that a given amount or degree of sensitivity can be repeated or
returned to with an accuracy of ±10% of the original pip height. If signal attenuators are used, they shall be accurate over
the attenuation range and test frequency used so that the attenuation measurement will represent an amplitude ratio
within ±10% of the correct value. The decibel (dB) attenuation value may be converted to an amplitude ratio by use of
tables with dB versus voltage ratios. Alternately, it may be calculated from the relationship in Equation 1.

–1 dB
Amplitude Ratio = Log ------ -------
10 20 (Eq. 1)

3.2.1.3 Voltage Regulation

If fluctuations in line voltage cause variations in the displayed signal amplitude or sweep length of ±5% or greater, a
power source voltage regulator shall be used. If fluctuations persist, proper adjustments to instrument or power source
shall be made so that the system will operate within the ±5% limits. Battery powered systems are exempt from this
requirement but such systems shall not be operated when the power source is below the level to achieve full vertical and
horizontal display as viewed on the CRT graticule.

3.2.1.4 Alarm

Test criteria and part configuration determine alarm use feasibility, and must be agreed upon by purchaser and vendor.
Audible and/or visual alarms shall be used in conjunction with visual monitoring to identify signals which exceed the level
established for the test. Alarm systems used for this purpose shall be capable of being adjusted to alarm at any point in
the display range of the CRT and shall be automatically triggered within ±10% of the set level. The sound level produced
by the alarm during operation shall be sufficiently above ambient to ensure being heard by the operator.
SAE AMS2630C Page 4 of 21

3.2.2 Ultrasonic Search Units

Ultrasonic search units shall be of a piezoelectric type capable of both transmitting and receiving ultrasonic signals at the
specific frequencies required by the test. When used with the ultrasonic test instrument, the search unit shall be capable
of transmitting and receiving ultrasonic energy with a spectral distribution that includes the central frequency required for
the test. The peak radiated frequency shall be within ±0.5 MHz or ±10%, whichever is greater, of the required frequency.
This history of each search unit shall be maintained in an appropriate log and shall include type, style, frequency, serial
number, and size. Beam profile checks, both axial and cross section, for immersion units may also be kept if required by
purchaser.

3.2.2.1 Search Unit Dimensions and Styles

For both contact and immersion tests with either longitudinal or shear mode, the choice of transducer dimension, style,
type, etc is dependent on the test and the approved test procedure. In general, for immersion testing, flat faced or
corrected beam transducers with diameters 3/8 through 1 inch (9.5 mm through 25.4 mm) or rectangular units with a
maximum area of 1 square inch are acceptable. Contact units with a maximum area of 1 square inch (6.5 cm2) with
1/2 inch (12.7 mm) minimum to 11/8 inches (28.6 mm) maximum dimensions are acceptable for longitudinal testing, while
1.0 inch x 1.0 inch (25.4 mm x 25.4 mm) or 1.0 inch x 1/2 inch (25.4 mm x 12.7 mm) transducers are acceptable for shear
testing. Use of a focused, paint brush, liquid delay, special size, or other special transducer is acceptable when agreed
upon by purchaser and vendor.

3.2.2.2 Test Frequencies

The frequency used shall be the highest practical frequency which will provide the penetration and resolution required;
frequencies lower than 2.25 MHz when using the longitudinal mode or 1.0 MHz when using a shear mode shall not be
used unless acceptable to purchaser.

3.2.2.3 Ultrasonic Beam Profiles for Immersion Units

The following are recommended, simplified (no special equipment required except a 3 mm ball) methods of finding Y+0
and distance amplitude curves and beam profiles. Complete performance parameters of ultrasonic transducers using
special equipment are presented in ASTM E 1065. Other methods or techniques for obtaining the same or similar data
may be used if acceptable to purchaser.

3.2.2.3.1 Axial Beam Profile

A distance amplitude curve of a transducer shall be plotted from measured energy reflected from a flat reflector having
dimensions greater than twice the sound beam diameter. The curve shall be plotted through at least the following
locations: the near field (Y-1) location, at the far field peak (Y+0) location, and at the 3 and 6 dB locations referenced from
the Y+0 point in both the near and far field directions. A distance amplitude curve shall be available before the transducer
is put into service. The curve may be supplied by the manufacturer or the purchaser may make the curve. Subsequent
periodic checks, at least annually, of the transducer shall include a distance amplitude curve which shall agree with the
original curve within ±20% for the transducer to be acceptable.

3.2.2.3.2 Cross Section Profile (Beam Symmetry)

The ratio of beam widths shall be not less than 0.75:1 when measured to the 6 dB points in two directions, 90 degrees
apart, across the beam at the Y+0 location. The measurements shall be made from energy reflected from a 0.118 inch
(3.0 mm) diameter steel ball. Larger diameter balls than those specified in ASTM E 1065 may be used when agreed upon
by purchaser and vendor.
SAE AMS2630C Page 5 of 21

3.2.2.4 Contact Test Angle-Beam Search Units

The exit point and exit angle of ultrasonic energy and depth profile of the sound beam shall be established for angle-beam
search units. Search units with beam angles departing more than ±3 degrees from manufacturer's indicated values shall
not be used. Such units may be requalified to a new angle by verifying proper operation and by reidentifying the unit to the
correct new beam angle. The International Institute of Welding (IIW) ultrasonic reference block or an appropriate
substitute may be used to test the exit angle of angle-beam search units.

3.2.3 Couplants

Shall be used for all tests.

3.2.3.1 Immersion Method

Couplants for testing by the immersion method may include any appropriate fluid such as tap water, light oils, ethylene
glycol, or alcohol. Such fluids may contain wetting agents to improve couplant properties or rust inhibitors to reduce
influence of the fluid on the product under test. No fluid may be used which stains, etches, or otherwise affects the
surface of the product under test. Any fluid used for immersion testing shall be free of visible air bubbles and shall not
exhibit excessive attenuation at the test frequency. The immersion technique is defined to include any liquid delay such
as bubblers, collimators, squirters, ultrasonic wheels, and immersion tanks.

3.2.3.2 Contact Method

Couplants for testing by the contact method shall not be injurious to the product being tested. Couplant materials include
any appropriate fluid such as water, light oils, low-viscosity greases, and penetrant emulsifiers. Rubber-like wear
membranes may be used between the search unit and the test part to prevent excessive search unit wear provided such
use is approved by purchaser. As surface roughness influences the sound energy, couplant viscosity may be varied as a
function of surface roughness. Table 1 provides a guide for selection of direct contact couplant materials; other couplants
of similar viscosity may be used. The contact technique is defined to include direct contact of a search unit with the test
surface, use of contour surface wearshoes, and thin-film couplant techniques such as the pressurized fluid (water gap)
system.

TABLE 1 - COUPLANT MATERIALS


Approximate Surface Roughness (ANSI B46.1) Couplant (SAE J300)
5 to 100 RHR (0.1 to 2.5 µm) SAE 10 Motor Oil
50 to 125 RHR (1.2 to 3.2 µm) SAE 20 Motor Oil
100 to 200 RHR (2.5 to 5.1 µm) SAE 30 Motor Oil

3.2.4 Ultrasonic Standards

Ultrasonic standards are required for all inspections. Calibration standards establish the performance of the inspection
system. Reference standards interrelate the test results with reference reflectors. It is mandatory that the materials used
for fabrication of ultrasonic references have ultrasonic properties similar to those of the product or part under test.
Whenever practical, the ultrasonic references shall be made from the same material and with the same configuration as
the part under test.

3.2.4.1 Material

Prior to fabrication, the material used for the ultrasonic reference shall be ultrasonically tested and proven to be free of
imperfections that would influence the test. At the frequency selected for the test, the ultrasonic transmission
characteristics shall not vary more than ±25% from those of the product or part to be tested.

3.2.4.2 Entry Surfaces

The configuration (surface roughness, flatness, or of the ultrasonic reference should approximate that of the product or
part to be tested. Requirements for a curved reference depend on type of test, direction of test, and size of search unit.
SAE AMS2630C Page 6 of 21

3.2.4.3 Longitudinal Wave Ultrasonic Reference (Straight Beam)

The procedures established under ASTM E 127 and ASTM E 428 are recommended for manufacturing ultrasonic
reference blocks for straight beam testing; these specifications describe the manufacture of flat-bottom holes (FBH) in
aluminum alloys and steels, but the same procedures may be used to manufacture references from other materials. The
entry surface may be square or round with minimum dimensions of 2 inches (50.8 mm) square or 2 inches (50.8 mm)
diameter. For blocks over 6 inches (152.4 mm) metal travel, a minimum entry surface of 3 inches (76.2 mm) square or
diameter is recommended. Step-type blocks may also be used provided the entry surface area for each step is in
agreement with that recommended for individual blocks. The flat-bottom hole (FBH) opening shall be plugged either as
recommended in ASTM E 127 and ASTM E 428 or with a water insoluble wax or similar material. Calibration standards
shall be dimensioned and have surface finishes as recommended by ASTM E 127 or ASTM E 428.

3.2.4.4 Shear Wave Ultrasonic References (Angle Beam)

May be of several distinct types as follows; because of the variety of types and sizes of acceptable shear wave calibration
standards, the shear wave standard(s) to be used shall be acceptable to purchaser:

3.2.4.4.1 Flat-bottom holes drilled at approximately 45 degrees to the entry surface may be used to test flat surfaces
(See Figure 3).

3.2.4.4.2 For testing cylinders, flat-bottom holes drilled in the center of the wall and perpendicular to the radius of the
cylinder may be used. Figures 4 and 5 illustrate two types of construction.

3.2.4.4.3 Side-drilled holes (SDH) may be used for shear wave calibration for both flat and curved entry surfaces. A
0.020 inch (0.51 mm) side-drilled hole 0.25 inch (6.4 mm) long is approximately equivalent to a #3 (1.2 mm
diameter) FBH, while the same diameter side-drilled hole 0.50 inch (12.7 mm) long is roughly equivalent to a
#5 (2.0 mm diameter) flat-bottomed hole (FBH) (See Figure 6). Comparisons of SDH to FBH sensitivity
should include consideration of the actual beam diameter intercepting the SDH. For example, if the beam
diameter is only 0.25” (6.4 mm), then the sensitivity would be approximately equivalent to a #3 FBH even if
the SDH is 0.5” (12.7 mm) long.

3.2.4.4.4 Various styles of notches may be used; these include V-notches, usually with a 60degree included angle,
square, or "U" bottomed notches, and slots. The sizes of the notches are generally equated to the test area
thickness (typically, 1 inch (25.4 mm) maximum length x 3% of the part thickness) or the notch area is
equated to a flat-bottom hole area; as an example, a 5/64 inch (2.0 mm) FBH has an area of 0.0047 square
inch (3.03 mm2) and a slot with a depth of 0.050 inch (1.27 mm) and a length of 0.10 inch (2.5 mm) has an
area of 0.005 square inch (3.2 mm2); therefore the notch and FBH are approximately equal.

3.2.4.5 Ultrasonic References for Inspection of Curved Surfaces

Use of reference blocks with curved entry surfaces shall be required. Generally, curved entry surfaces with radii of
5 inches (127 mm) or greater may be tested using either flat entry surface standards, or curved standards with the
curvature ±10% of that of the part being tested. For test surfaces with radii between 2 and 5 inches (50.8 and 127 mm), a
reference standard with a 3-inch (76.2-mm) radius may be used. For test surfaces with radii up to 2 inches (50.8 mm), a
reference standard with a 1 inch (25.4-mm) radius may be used.

3.2.4.6 Special Ultrasonic References

Where the part geometry dictates the need for using the actual part or part replica as an ultrasonic reference, all
simulated defects shall be machined in accordance with the practices specified for longitudinal and shear wave
inspection. Ultrasonic references made from actual parts or part replicas are recommended wherever practical. The
standard design shall be subject to approval by the purchaser.
SAE AMS2630C Page 7 of 21

3.3 Surface Preparation

Visual examination shall be performed on each part to ensure that sound beam entry surfaces are free from loose scale,
oxides, oil, grease, machining or grinding particles, excessive machining or grinding marks, and other surface conditions
that could interfere with the sound beam and affect the test. Surface textures for machined parts shall be determined in
accordance with ANSI B46.1. Surfaces to be inspected shall be not rougher than 63 microinches (1.6 µm) for Class AA.
Classes A1 and A longitudinal wave tests and most shear wave tests require surfaces no rougher than 125 microinches
(3.2 µm). A surface texture up to 250 microinches (6.35 µm) is acceptable for testing to Class B. Surface textures for
testing to Class C become part of the Class "C" agreement. Unmachined part surfaces should have a texture
approximately equivalent to that of machined surfaces as required for each class. When permitted by purchaser,
inspections may be made on surfaces that are rougher than those specified herein, provided that the ultrasonic reference
standards have a comparable surface finish. Sound beam exit surface (back face) requirements vary greatly, dependent
on the tests performed. Some tests require back reflection surfaces to meet conditions similar to those required for the
entry surfaces while on other types of parts, particularly fabrications and castings, it may be impractical to change the
surface quality and in some cases it may even be impossible to examine the exit surface.

3.4 Testing Procedure

3.4.1 Written Procedure

Ultrasonic inspections performed in accordance with this specification shall be detailed in written procedures. Unless
otherwise specified, procedures shall be prepared by the vendor and shall be subject to approval by the purchaser.
Procedures shall identify the type of ultrasonic equipment, method(s) of test, ultrasonic test reference, search unit type,
style, frequency, method of reporting indications, and all other instructions that pertain to the actual test. Procedures shall
be detailed sufficiently such that another investigator could duplicate the test and obtain equivalent information.

3.4.2 Documentation

Shall provide for the complete inspection procedure for each product (size, shape, and alloy) or part to be inspected.
Documentation format is flexible, but sketches, photographs, and graphics are recommended wherever practical.
Because of the variety and complexity of tests that can be performed, the documentation of the inspection plan and the
methods of recording and interpreting results become very important. This specification is not intended to restrict
documentation beyond that which provides valid and reproducible quality control tests. As a minimum, the procedure shall
specify:

3.4.2.1 Specific product or specific part number (where applicable), stage of fabrication, surface condition, and
configuration of the product to be tested.

3.4.2.2 Manufacturer and model numbers of instrumentation modules, recording equipment if used, fixturing, tanks,
manipulators, and coupling means used in the test.

3.4.2.3 The type of ultrasonic references used to calibrate equipment and the calibration procedure.

3.4.2.4 Testing plan, including the recording procedures, scanning plan, sensitivity, method of interpreting results, and
relationship to ultrasonic references.

3.4.3 Testing System

3.4.3.1 The product or part may be inspected by longitudinal or shear wave techniques or a combination of techniques
as will most appropriately disclose material imperfections.

3.4.3.2 All equipment used for the tests, such as ultrasonic test instrument, ultrasonic search units, ultrasonic
references, recording system, and electronic gates, shall be assembled in one location and evaluated as a
complete system. Once assembled, they shall remain together as part of the test equipment until the tests are
completed. Any substitution of electronic gates, displays, search units, and other similar equipment for any
reason shall require recalibration of the complete system.
SAE AMS2630C Page 8 of 21

3.4.4 Qualification Calibration of Test System

Before inspecting any product or part, the test system shall be qualified by adjusting the sensitivity, pulse duration,
damping, or other external controls so that the signals reflected from known discontinuities in appropriate ultrasonic
references can be clearly identified as separate and discrete indications. During initial calibration, signal amplitude
(sensitivity) from a known reference discontinuity may be set within the range of 20 to 90% of the vertical height of the
CRT screen. Sensitivity may be increased during test by a predetermined dB level to ensure an adequate test; however,
when interpreting results, the sensitivity shall be returned to the original setting.

3.4.4.1 Calibration Record

When permanent records, such as wet or dry paper, xy recorders, or digital computer, are established as part of the test
plan, calibration of the test system shall include a record of the appropriate ultrasonic reference reflector.

3.4.4.2 Calibration Check

To ensure valid results, a calibration check shall be made prior to the test of each part configuration or start of each shift
of operation and at the completion of each test or shift, as appropriate. Calibration checks performed at the start of an
immediately subsequent shift shall satisfy end of shift requirements. Any change in equipment operation that requires a
recalibration of the test system shall require retesting of all product or parts tested since the previous calibration as in
3.4.9.1.2.

3.4.5 Immersion Inspection

3.4.5.1 Immersion Fluid

Shall be as specified in 3.2.3.1.

3.4.5.2 Longitudinal (Straight) Beam Testing

The sound beam entry angle shall be adjusted until the sound beam is perpendicular to the test surface. Where
appropriate, the maximum signal amplitude from the entry surface may be used to determine this condition. Where not
appropriate, e.g., a highly-focused search unit, an alternate procedure such as multiple reflections may be used. During
testing, the angle established shall not vary more than ±2 degrees. When contoured parts are being inspected, a surface
or contour follower may be employed so that the surface entry angle is maintained perpendicular within ±2 degrees.

3.4.5.3 Angle Beam Testing

Products may be inspected with both longitudinal and shear wave motions at preselected angles. Once established, the
surface entry angle shall not vary more than ±2 degrees.

3.4.5.4 Water Path

When practicable, the test shall be calibrated and run using water paths that result in inspection being performed in the
far field. A variety of sound beams, ranging from collimated to highly-focused, may be used. Special interpretation of test
results may be necessary to characterize the discontinuity. A variety of test zones are possible but changing the test zone
by varying the water path during test may present serious complications. During the test, the established water path (i.e,
the distance from the face of the search unit to the entry surface) shall not vary more than ±0.25 inch (±6.4 mm) from that
used for calibration.
SAE AMS2630C Page 9 of 21

3.4.6 Contact Testing

3.4.6.1 Angle Beam Testing

The sound beam entry angle and the testing mode shall be established as part of the test procedure. The search unit
qualification tests will establish the exit point and angle of exit. If wear of contact shoes or search unit results in a change
in sound beam entry angle of more than ±3 degrees from the established angle, that search unit shall be replaced,
repaired, or requalified to a new angle in accordance with 3.2.2.4. The wedge or contact shoes shall be examined visually
for signs of poor contact between the transducer piezoelectric element and wedge or shoe. At any sign of insufficient
coupling, the search unit assembly shall be taken apart, the contact surfaces cleaned, new couplant applied, and the unit
reassembled.

3.4.6.2 Straight Beam Testing

Search unit qualification tests shall establish the sound beam character for the straight beam search unit. Visual
inspection of the search unit shall be made to verify that the wear face surface is intact. Periodic visual inspections shall
be made during tests to ensure that the search unit facing has not degraded. Any cracking, chipping, break-up, or uneven
wear conditions shall disqualify the search unit and the test.

3.4.7 Special Testing

3.4.7.1 Surface Wave

Special attention shall be given to ensuring surface cleanliness before and during a surface wave test. Every precaution
shall be exercised to remove excess couplant, foreign material, and other matter that could influence the test.

3.4.7.2 Dual Search Units

For high-resolution, near-zone testing, dual search unit techniques may be used. The qualification for dual search unit
shall be the same as for contact testing. If wear of the search unit results in a change in sound beam entry angle greater
than ±3 degrees, the search unit shall be removed from service and replaced or repaired.

3.4.8 Distance Amplitude Correction (DAC)

Electronic distance amplitude correction is recommended; however, distance amplitude curves plotted on the CRT screen
face using distance amplitude calibration blocks may be used if the minimum pip height is not less than 20% and the
maximum pip height is not greater than 80% of the vertical limit. For pip heights greater than 80%, the DAC curve is
extended parallel to the baseline at a predetermined vertical limit level, usually 80%. Multiple curves shall be established
for those areas above the predetermined level to properly evaluate discontinuities in the area. Testing using the highest
sensitivity from the distance amplitude calibration blocks and evaluating to the proper metal travels is also permitted
provided noise levels do not obscure required information.

3.4.9 Electronic Alarm Gating and Recording

Wherever possible and practical, automatic signal alarm circuits shall be used. Automatic recording of test results is a
special requirement that should be agreed upon by purchaser and vendor.

3.4.9.1 Electronic Gating

3.4.9.1.1 Electronic gating may be used for depth and signal recording. Both interface gating and pulse synchronization
are applicable. For automatic recording, the gates used shall maintain stable gate positions and gate widths
throughout the test. Signal amplitude gates shall record a linear relationship, within ±5% of full scale
deflection, between the signal displayed on the CRT and the recorded signal of the electronic gate over the
range of 20 to 80% of the vertical amplitude displayed on the CRT.
SAE AMS2630C Page 10 of 21

3.4.9.1.2 At the start of each testing shift, the ultrasonic reference shall be recorded and compared with the acceptance
recording. At the completion of the testing shift, a second recording shall be made and compared with the
starting recording. Any deviation of a reference reflector in excess of +/- 10% FSH between start and ending
recordings shall require system recalibration. Deviations less than -10% FSH shall require that all parts
inspected since the last valid calibration be reinspected. Deviations greater than +10% shall require re-
evaluation of all rejected indications since the last valid calibration. For this requirement, testing shifts shall
not exceed eight hours.

3.4.9.2 Recording

Recording may be performed by the operator in accordance with good engineering practices. Automatic permanent
records may utilize line storage display oscilloscopes, photographs of CRT recordings, chart recorders, facsimile
recorders, e.g., dry or wet paper, or other equivalent recording devices. No restriction is placed on the type of recorder
used except as limited by the instrument characteristics. Such test parameters as scanning speed, amplifier frequency
response, electronic gate response, and recorder response may limit the selection of the permanent recorder to be used.
During the selection and qualification of the testing system, the vendor shall provide the purchaser with evidence that the
recording system is not the limiting component of the system and that reflections from known discontinuities are reliably
and repeatedly portrayed. If the recorder is established as the limiting system component, the scanning and recording
speeds shall be reduced to fall within the limitations of the recorder.

3.4.9.3 Scanning Index

In determining the index for 100% coverage, the effective beam diameter (EBD) shall first be measured. Using the
assigned calibration standards, proper calibration gains, and water travel, measure the total traversing distance across
the calibration blocks through which no less than 50% of the reference response is obtained. This distance will vary for
each calibration block, dependent on the metal travel to the test hole. The least of the distances determined is the EBD .
The maximum scanning increment shall not exceed 70% of the EBD.

3.4.9.4 Scan Speed

Maximum scanning speed shall be determined by readability or recordability of the applicable ultrasonic reference. At the
maximum speed used, the reference discontinuities shall be clearly discernible. If distortion related to scanning speed is
observed, the scan speed shall be reduced until distortion is eliminated. As a general rule, the maximum scanning speed
for automatic scanning with automatic gates, alarms, etc is 20 inches (508 mm) per second and for manual scanning and
visual reading of the CRT is 6 inches (152.4 mm) per second. Higher scanning speeds may be possible and, when
suitably demonstrated, may be used when agreed upon by purchaser and vendor.

3.4.9.5 Gain Settings for Scanning

For automatic scanning inspection, the gain setting as established from the ultrasonic reference shall be used. The alarm
shall be set to activate at a signal level equal to 50% of the distance amplitude curve for the material zone being
inspected. If electronic distance amplitude correction (DAC) is employed, alarm activation level shall be set at 50% of the
displayed signal. For manual scanning which monitors the amplitude of reflections from internal discontinuities, the gain
level from the ultrasonic reference shall be established and 6 dB added, provided the added sensitivity does not increase
the noise level more than 50% of the recordable indication height; when alarm systems are used with manual scanning,
the alarm trigger level is normally set as for automatic scanning and it is not necessary to add extra sensitivity.

4. QUALITY ASSURANCE PROVISIONS

4.1 Acceptance Classes

4.1.1 Longitudinal Wave Inspection Using Flat-Bottom Holes (FBH)

Five classes of ultrasonic quality are established for longitudinal wave inspection. Table 2 defines these classes for
inspections involving flat-bottom hole reflectors in ultrasonic references.
SAE AMS2630C Page 11 of 21

TABLE 2A - LONGITUDINAL WAVE INSPECTION PARAMETERS, INCH/POUND UNITS


Loss of
Single Multiple Linear Back
Quality Discontinuity Discontinuities Discontinuity Reflection
Class FBH Size (1) FBH Size (1) inch, max %, max
AA #3 #1 (2) #1 response for 0.12 50
A1 #3 #2 (3) #2 response for 1.00 50
A #5 #3 #3 response for 1.00 50
B #8 #5 #5 response for 1.00 50
C As established by purchaser and vendor for specific part.
Notes:
1. FBH numbers indicate diameter in multiples of 1/64 inch of FBH in ultrasonic reference.
2. 11% of a #3 FBH is equivalent to a #1 FBH and may be used in place of the response from the #1 FBH.
3. 44% of a #3 FBH is equivalent to a #2 FBH and may be used in place of the response from the #2 FBH.

TABLE 2B - LONGITUDINAL WAVE INSPECTION PARAMETERS, SI UNITS


Loss of
Single Multiple Linear Back
Quality Discontinuity Discontinuities Discontinuity Reflection
Class FBH Size (1) FBH Size (1) mm, max %, max
AA 1.2 0.4 (2) 0.4 response for 3.0 50
A1 1.2 0.8 (2) 0.8 response for 25 50
A 2.0 1.2 1.2 response for 25 50
B 3.2 2.0 2.0 response for 25 50
C As established by purchaser and vendor for specific part.
Notes:
1. Diameter of flat-bottom hole in millimeters.
2. Percentage equivalents of the 1.2 mm FBH may be used. See Notes 2 and 3 in
Table 2A.

4.1.1.1 Any discontinuity with a signal indication greater than allowed for the specific class shall disqualify the part for
that class.

4.1.1.2 Multiple discontinuities are defined as two or more indications above the level established for the class that
occur within 1 cubic inch (16.4 cm3).

4.1.1.3 Loss of back surface reflection caused by an internal metallurgical condition showing a signal loss more than
50% of the distance amplitude curve established for the material is not acceptable.

4.1.2 Angle Beam Tests Using Flat-Bottom Holes (FBH)

Five classes of ultrasonic quality are established for angle beam inspection, in either shear or longitudinal modes, which
involves flat-bottom holes for ultrasonic reference reflectors. Table 3 defines these classes.

TABLE 3A - ANGLE BEAM ULTRASONIC INSPECTION PARAMETERS, INCH/POUND UNITS


Single Multiple
Quality Discontinuity Discontinuities Linear Discontinuity
Class FBH Size (1) FBH Size Inch, max
AA #2 50% of #2 response 50% of #2 response for 0.12
A1 #3 #2 #2 response for 0.25
A #5 #3 #3 response for 0.50
B #8 #5 #5 response for 1.00
C As established by purchaser and vendor for specific part.
Notes:
1. FBH numbers indicate diameter in multiples of 1/64 inch of FBH in ultrasonic reference.
SAE AMS2630C Page 12 of 21

TABLE 3B - ANGLE BEAM ULTRASONIC INSPECTION PARAMETERS, SI UNITS


Single Multiple
Quality Discontinuity Discontinuities Linear Discontinuity
Class FBH Size (1) FBH Size mm, max
AA 0.8 50% of 0.8 FBH response 50% of 0.8 FBH response for 3.0
A1 1.2 0.8 FBH 0.8 FBH response for 6.4
A 2.0 1.2 FBH 1.2 FBH response for 12.7
B 3.2 2.0 FBH 2.0 FBH response for 25.4
C As established by purchaser and vendor for specific part.
Notes:
1. Diameter of flat bottom hole in millimeters.

4.1.2.1 Any discontinuity with a signal indication greater than allowed for the specific class shall disqualify the part for
that class.

4.1.2.2 Multiple discontinuities are defined as two or more indications above the level established for the class that
occur with 1 cubic inch (16.4 cm3) of inspected surface.

4.1.3 Angle Beam Testing Using Reference Notches

The acceptance classes used to determine quality levels using various types of notches or side-drilled holes shall be as
agreed upon by purchaser and vendor.

4.2 Disposition

4.2.1 Product exhibiting evaluated indications not in excess of limits for its specified quality class may be accepted
without remedial operations.

4.2.2 Product exhibiting evaluated indications in excess of limits for its specified quality class, but in a location which
will be removed during manufacturing operations, may be approved by the cognizant quality assurance activity for
acceptance.

4.2.3 Product containing discontinuities in excess of limits for its specified quality class and not covered by 4.2.2 shall
be rejected.

4.3 Records

4.3.1 General

The testing source shall prepare and maintain on file, for the time specified by purchaser, records of the requirements and
techniques for either each size and configuration of product and of each part number or general records covering families
of products. These records shall be made available for inspection by purchaser upon request.

4.3.2 Personnel Qualifications

It shall be verified that all inspections are performed by personnel qualified as in 3.1.1. A list of qualified personnel shall
be maintained for purchaser's review upon request.

4.3.3 Instrument and System Qualification

It shall be verified that the instrument and system used in the inspection meet the requirements set forth herein.

4.3.4 Search Unit Qualification

Documentation regarding the qualification of search unit performance shall be maintained. Qualification tests shall be
related to the time of actual test.
SAE AMS2630C Page 13 of 21

4.3.5 Procedure Verification

Copies of the written testing procedure shall include the type and response of the ultrasonic reference to be used and
shall be maintained as part of the documentation. The procedure shall be reviewed periodically by vendor's cognizant
supervisor to ensure that inspection is in compliance with this specification.

5. PREPARATION FOR DELIVERY

Not applicable.

6. ACKNOWLEDGMENT

A vendor shall mention this specification number and its revision letter in all quotations and when acknowledging
purchase orders.

7. REJECTIONS

Product not inspected in accordance with this specification, or to modifications authorized by purchaser, will be subject to
rejection.

8. NOTES

8.1 A change bar (|) located in the left margin is for the convenience of the user in locating areas where technical
revisions, not editorial changes, have been made to the previous issue of this document. An (R) symbol to the left
of the document title indicates a complete revision of the document, including technical revisions. Change bars and
(R) are not used in original publications, nor in documents that contain editorial changes only.

8.2 Test Conditions

It is essential that thorough understanding be developed between purchaser and vendor regarding interpretation of the
results of inspection and how they shall be recorded and reported. Ultrasonic indications may appear which do not reflect
conditions detrimental to use of the product. Purchaser and vendor should establish agreement on the following
parameters prior to acceptance testing:

Surface finish

Internal structure

Location and extent of areas to be scanned and applicable quality class

Size of transducer and type of search unit

Test frequency

Type and grade of couplant

Method of calibration of equipment

8.3 Distance Amplitude Correction

The following discussion relates to and defines terms and procedures recommended in 3.4.8.

8.3.1 Distance Amplitude (DA) Curve

The ultrasonic sound beam propagated from the search unit will vary in accordance with physical laws. Specific size holes
at different depths within the material will reflect proportionately different energies and the display will record a
corresponding progression of signal amplitudes. The curve plotted on the CRT is referred to as the distance amplitude
(DA) curve.
SAE AMS2630C Page 14 of 21

8.3.2 Distance Amplitude Correction (DAC) Circuitry

To normalize the inherent influence resulting from the distance amplitude curves, electronic circuits known as distance
amplitude corrections (DAC) are employed. These electronic circuits provide a variable gain versus depth function which
normalizes the distance amplitude curve signals displayed on the CRT to a preselected amplitude.

8.3.3 Applications

8.3.3.1 DA curves and DAC circuitry may be utilized for straight-beam, angle-beam, and surface-wave tests. A
minimum of three points are required to establish a DA curve. When the DA curve is used, the maximum
amplitude point on the curve should not exceed 80% and the minimum point should be not less than 20% of the
maximum vertical deflection displayed on the CRT. If these limits cannot be maintained, multiple curves should
be used to cover the range of material being inspected. Once the DA curve is established for an appropriate set
of ultrasonic references, reflections may be recorded as percentages of this curve or the sensitivity may be
adjusted to establish a ±dB relationship between the unknown discontinuity and the known reference.

8.3.3.2 For automatic recording systems, use of DAC circuitry is recommended. Care should be exercised to ensure
that the DA curve falls within the linear sensitive range of the electronic recording gate; 50% vertical amplitude
display is recommended.

8.3.3.3 DA curves are applicable to focused and non-focused search units but are not as accurate for testing in the
near field of the search unit.

8.4 Reference Publications

Nondestructive Testing Handbook, edited by Dr. R. C. McMasters, 1959; Ronald Press, 70 Madison Avenue, New
York, NY 10016 (Available from ASNT).

Sonics, by T. F. Hueter and R. H. Bolt, 1955; John Wiley & Sons, Inc., 605 Third Avenue, New York, NY 10016.

Ultrasonic Testing of Materials, by J. Krautkramer and H. Krautkramer (Translation of 2nd revised German edition),
1969; Springer-Verlag New York, 175 Fifth Avenue, New York, NY 10010.

AMS2631 Ultrasonic Inspection of Titanium Alloys

8.5 Terms used in AMS are clarified in ARP1917.

8.6 Dimensions and properties in inch/pound units and the Fahrenheit temperatures are primary; dimensions and
properties in SI units and the Celsius temperatures are shown as the approximate equivalents of the primary units
and are presented only for information.

PREPARED BY AMS COMMITTEE "K"


SAE AMS2630C Page 15 of 21

FIGURE 1 - CALIBRATION BLOCK USED FOR EVALUATING VERTICAL LINEARITY


SAE AMS2630C Page 16 of 21

FIGURE 2

FIGURE 2A
SAE AMS2630C Page 17 of 21

FIGURE 3A - STANDARD ULTRASONIC TEST BLOCK FOR ANGLE BEAM EXAMINATION, INCH/POUND UNITS
SAE AMS2630C Page 18 of 21

FIGURE 3B - STANDARD ULTRASONIC TEST BLOCK FOR ANGLE BEAM EXAMINATION, SI UNITS
SAE AMS2630C Page 19 of 21

FIGURE 4
SAE AMS2630C Page 20 of 21

FIGURE 5 - ALTERNATE HOLE STANDARD FOR WALL THICKNESS OVER 0.50 INCH (12.7 MM)
SAE AMS2630C Page 21 of 21

FIGURE 6 - REFERENCE STANDARD FOR CIRCUMFERENTIAL SHEAR WAVE INSPECTION