Technical Data TWD1240VE: General

Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

Technical data TWD1240VE

General
In-line four stroke diesel engine with direct injection. Rotation direction, anti-clockwise viewed towards flywheel

Number of cylinders 6
Displacement, total liters 12,13
in3 740
Firing order 1-5-3-6-2-4
Bore mm 131
in 5,16
Stroke mm 150
in 5,91
Compression ratio 18,5:1
Dry weight Engine kg 1270
lb 2800
Power Pac kg 1660
lb 3660

Performance r/min 1500 1800 2000 2100


IFN Power. 310 kW without fan kW 310 310 310 310
hp 422 422 422 422
with fan kW 306 303 300 298
750 mm hp 416 412 408 405
IFN Power. 294 kW without fan kW 294 294 294 294
hp 400 400 400 400
with fan kW 290 287 284 282
750 mm hp 394 390 386 384
ICFN Power. 275 kW without fan kW 275 275 275 275
hp 374 374 374 374
with fan kW 271 268 265 263
750 mm hp 369 364 360 358
ICFN Power. 256 kW without fan kW 256 256 256 256
hp 348 348 348 348
with fan kW 252 249 246 244
750 mm hp 343 339 335 332
Torque at: IFN Power. 310 kW Nm 1974 1645 1480 1410
lbf ft 1455 1213 1092 1040
IFN Power. 294 kW Nm 1872 1560 1404 1337
lbf ft 1380 1150 1035 986
ICFN Power. 275 kW Nm 1751 1459 1313 1251
lbf ft 1291 1076 968 922
ICFN Power. 256 kW Nm 1630 1358 1222 1164
lbft 1202 1002 901 859
Mean piston speed m/s 7,5 9,0 10,0 10,5
ft/sec 24,6 29,5 32,8 34,4
Effective mean pressure at ICFN Power Mpa 1,81 1,51 1,36 1,30
psi 262 219 197 189
Max combustion pressure at ICFN Power MPa 15,3 15,7 15,5 14,8
psi 2219 2277 2248 2146
2 2
Total mass moment of inertia, J (mR ) kgm 3,64
2
lbft 86,4
Degree of irregularity at: IFN Power. 310 kW 1:54 1:114 1:186 1:226
ICFN Power. 275 kW 1:65 1:138 1:231 1:270
Residual speed droop at load increase from 0 IFN Power. 310 kW % 0-8
to 100% at: ICFN Power. 275 kW % 0-8
Friction Power kW 27 38 47 52
Technical data TWD1240VE
Derating
The engine will operate up to 1100m altitude without derating. For
operation at higher altitudes the power will be derated according to the
following factors: Linear interpolation is active between 1100m and
5000 m
r/min 1500 1800 2000 2100
Altitude derating factor at 1100 m % 0
Altitude derating factor at 5000 m % 10
Ambient temperature derating factor % / °C No derating
Humidity No derating

Lubrication system r/min 1500 1800 2000 2100


Lubricating oil consumtion at max rpm at: IFN Power. 310 kW liter/h 0,11
US gal/h 0,029
ICFN Power. 294kW liter/h 0,10
US gal/h 0,026
Oil system capacity incl. Filters liter 35
US gal 9,25
Oil sump capacity: Max liter 31
US gal 8,19
Min liter 19
US gal 5,02
Engine angularity limits: front up ° 11
front down ° 11
side tilt ° 11
Oil pressure: at rated speed kPa 400-500
shut down switch setting kPa 250
Lubrication oil temperature: normal °C 120
°F 248
max °C 130
°F 266
Oil filter micron size mm 0,040
Technical data TWD1240VE
Fuel system r/min 1500 1800 2000 2100
IFN Power. 310 kW 25% g/kWh 220 239 255 280
Specific fuel consumption at: lb/hph 0,357 0,387 0,413 0,454
50% g/kWh 197 207 217 235
lb/hph 0,319 0,336 0,352 0,381
75% g/kWh 196 200 212 234
lb/hph 0,318 0,324 0,344 0,379
100% g/kWh 195 199 209 227
lb/hph 0,316 0,323 0,339 0,368
ICFN Power. 275 kW 25% g/kWh 237 256 307 297
Specific fuel consumption at: lb/hph 0,384 0,415 0,498 0,481
50% g/kWh 201 213 236 243
lb/hph 0,326 0,345 0,383 0,394
75% g/kWh 197 203 222 229
lb/hph 0,319 0,329 0,360 0,371
100% g/kWh 196 200 217 223
lb/hph 0,318 0,324 0,352 0,361
Recommended fuel to conform to ASTM-D975-No1 and 2-D
JIS KK 2204, EN 590
Total fuel flow liter/h 105 110 115 120
Feed pump pressure kPa 350
Feed pump max suction head m 2
Fuel filter micron size mm 0,005
Prefilter / Waterseparator micron size mm 0,030
Governor type/make Electronic / EDCIII

Intake and exhaust system r/min 1500 1800 2000 2100


Air consumption at: IFN Power. 310 kW m³/min 22,8 26,7 29,2 31,3
cfm 805 943 1031 1105
ICFN Power. 275 kW m³/min 20,3 24,4 27 29,4
cfm 717 862 954 1038
Air intake restriction, clean filter(s) kPa 2
In wc 8,0
Max allowable air intake restriction kPa 5
ln wc 20,1
Heat rejection to exhaust at: IFN Power. 310 kW kW 202 231 244 258
BTU/min 11488 13137 13876 14672
Exhaust gas temperature after turbine at: IFN Power. 310 kW °C 470 425 425 455
°F 878 797 797 851
ICFN Power. 275 kW °C 460 410 400 420
°F 860 770 752 788
Max allowable back pressure in exhaust line kPa 9,0 11,0 14,0 15,0
In wc 36,1 44,2 56,2 60,2
Exhaust gas flow at: IFN Power. 310 kW m³/min 56,4 60,2 64,2 70,6
cfm 1992 2126 2267 2493
ICFN Power. 275 kW m³/min 49,6 53,7 57,1 62,9
cfm 1752 1896 2016 2221
Exhaust gas smoke IFN Power. 310 kW Bosch 0,15 0,10 0,11 0,32
ICFN Power. 275 kW Units 0,10 0,10 0,11 0,27
Technical data TWD1240VE
Cooling system r/min 1500 1800 2000 2100
Heat rejection radiation from engine at: IFN Power. 310 kW kW 14 14 18 22
BTU/min 796 796 1024 1251
ICFN Power. 275 kW kW
BTU/min 0 0 0 0
Heat rejection to coolant at: IFN Power. 310 kW kW 160 182 192 199
BTU/min 9099 10350 10919 11317
ICFN Power. 275 kW kW 156 179
BTU/min 0 8872 0 10180
Recommended coolant Volvo coolant toghether
with clean fresh water
Radiator cooling system type Closed circuit
Radiator core area (std. size) m² 0,8
foot² 8,61
Radiator core thickness (std. size) mm 50
in 1,97
Fan diameter 890 mm (std. size) Power Pac mm 890
in 35,04
750 mm mm 750
in 29,53
Fan power consumption 890 mm kW 7,0 12,0 16,0 19,0
hp 10 16 22 26
750 mm kW 4,0 7,0 10,0 12,0
hp 5 10 14 16
Fan drive ratio 890 mm (std. size) Power Pac 0,93:1
750 mm 0,93:1
Coolant capacity: engine liter 20
US gal 5
std. radiator with hoses liter 24
US gal 6
Coolant pump drive/ratio gear/1,41:1
Coolant flow including radiator restriction l/s 4,8 6,0 6,7 7,1
US gal/s 1,3 1,6 1,8 1,9
Maximum permissable external coolant system restriction kPa 70,0
in wc 281,1
Thermostat: start to open °C 75
°F 167
fully open °C 88
°F 190
Maximum static pressure head kPa 70
in wc 281,1
Maximum pressure cap setting kPa 70
in wc 281,1
Maximum top tank temperature °C 103
°F 217
Minimum temperature entering engine °C 68
°F 154
Shutdown swich setting °C 103
°F 217
Recommended drawdown capacity 10% of total cooling system capacity
Technical data TWD1240VE
Cooling performance: 0,8 m² radiator and 750 mm fan
Cooling air flow and maximum additional external restriction at different radiator air temperatures based on 100°C
TTT and 50% antifreeze
IFN POWER
Engine speed Engine Max additional
Air on temp Air flow
power external restriction
kW
rpm hp °C °F m³/s cu ft/s Pa psi
2100 310 40 104 4,2 148,3 600 0,087
422 50 122 5,7 201,3 300 0,044
56 133 7,4 261,3 0

1800 310 40 104 3,9 137,7 350 0,051


422 50 122 5,3 187,2 150 0,022
54 129 6,2 219,0 0

Cooling performance: 0,8 m² radiator and 750 mm fan


Cooling air flow and maximum additional external restriction at different radiator air temperatures based on 100°C
TTT and 50% antifreeze
ICFN POWER
Engine speed Engine Max additional
Air on temp Air flow
power external restriction
kW
rpm hp °C °F m³ cu ft/s Pa psi
2100 275 50 122 4,5 158,9 600 0,087
374 60 140 6,8 240,1 200 0,029
62 144 7,5 264,9 0

1800 275 50 122 3,7 130,7 400 0,058


374 60 140 5,4 190,7 100 0,015
63 145 6,3 222,5 0

Cooling performance: 0,8 m² radiator and 890 mm fan


Cooling air flow and maximum additional external restriction at different radiator air temperatures based on 100°C
TTT and 50% antifreeze
ICFN POWER
Engine speed Engine Max additional
Air on temp Air flow
power external restriction
kW
rpm hp °C °F m³ cu ft/s Pa psi

1800 294 50 122 4,1 144,8 900 0,131


400 60 140 6,1 215,4 500 0,073
65 149 8,1 286,0 0

1500 294 50 122 4,3 151,9 450 0,065


400 60 140 6,5 229,5 0
Technical data TWD1240VE
Electrical system
Voltage and type 24V / Insulated from ground
Alternator: make Valeo
output Amp 60
tacho output Hz/alternator rev. 6
drive ratio 3,41:1
Starter motor: make Bosch
type GVB
output kW 6
Starter motor solenoid: pull current Amp
hold current Amp <2
Number of teeth on: flywheel 156
starter motor 12
Inrush current at +20°C Amp 1500-1650
Cranking current at +20°C Amp 400
Crank engine speed at 20°C rpm 200
Starter motor battery capacity max Ah 2x143 570A DIN
min at +5°C Ah 2x88 400A DIN
Inlet manifold heater (at 20 V) (Optional equipment) kW 2,8
Power relay for the manifold heater Amp 1

Power take off r/min 1500 1800 2000 2100


Front end in line with crank shaft max: Nm 600
lbf ft 443
Front end belt drive pully max left kW 30 30 62 62
hp 41 41 84 84
max down kW 19 31 28 28
hp 26 42 38 38
max right kW 30 30 62 62
hp 41 41 84 84
Timing gear at compressor PTO max: Nm 140
lbf ft 103
Speed ratio / direction of rotation viewed from flywheel side 1,31:1 / anti-clockwise
Timing gear at servo pump PTO max: Nm 40
lbf ft 30
Speed ratio / direction of rotation viewed from flywheel side 1,65:1 / anti-clockwise
Timing gear at hydraulic pump PTO max: Nm 400
lbf ft 295
Speed ratio / direction of rotation viewed from flywheel side 0,97:1 / anti-clockwise