Series 919 Specification Sheet
Series 919 Specification Sheet
Series 919 Specification Sheet
Series 919
Features
Separate access covers for the check valves and relief valve for ease of maintenance Top entry-all check internals easily accessible All rubber elastomers of chloramine resistant material Check valve poppet assemblies are fully guided by innovative plastic seat guide Replaceable push-in check valve and relief valve seats eliminates threads from the water way EZ twist relief valve cover quarter-turn locking joint captures the spring load during repair to facilitate disassembly Innovative check valve plastic cover bushing provides trouble free guiding of the check valve poppet Bottom mounted relief valve provides reduced installation clearances Compact, space saving design No special tools required for servicing Top mounted test cocks for ease in testing and reduced installation clearances Standardly furnished with NPT body connections
Specifications
A Reduced Pressure Zone Assembly shall be installed at each potential health hazard location to prevent backflow due to backsiphonage and/or backpressure. The assembly shall consist of a pressure differential relief valve located in a zone between two positive seating check valves. Seats and seat discs shall be replaceable in both check valves and the relief valve without the use of special tools. Service of all internal check valve components shall be through top mounted access bronze covers threaded to the main valve body. The check valve poppet assembly shall be guided via the use of a corrosion resistant plastic guide. The check valve and relief valve seats shall be push-in type. The relief valve cover shall be bronze construction secured with stainless steel bolts and shall utilize a quarter-turn locking joint to capture the spring load of the relief valve. The relief valve shall have an internal sensing line to sense the inlet water supply. All rubber elastomers shall be of chloramine resistant material. The assembly shall also include two resilient seated isolation valves, four top-mounted resilient seated test cocks and an air gap drain fitting. The assembly shall be a Watts Series 919.
Now Available
Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold.
Available Models
Suffix: QT quarter-turn ball valves S bronze strainer LF without shutoff valves AQT elbow fitting for 360 rotation ZQT inlet & outlet flow up FP slow close ball valves Prefix: U union connections
Pressure Temperature
Temperature Range: 33F 180F (0.5C 82C) Maximum Working Pressure: 175psi (12.1 bar)
Air Gaps
A
Materials
Body: Bronze Discs: Silicone rubber Check Seats: Replaceable polymer Cover Bolts: Stainless steel C
AIR GAP MODEL "-2" LF and FP models only SIZES DIMENSIONS WEIGHT A in. mm in. B mm in.
12
Approvals
1013
34
C mm lbs. kg.
Approved by the Foundation for Cross-Connection Control and Research at The University of Southern California (for sizes 34" -2")
919AGC 919AGF
" 1" 238 60 318 79 114" 2" 438 111 8716 214
14
Dimensions Weights
D A
G F
919QT, 919QT-S
Size (dn) in. mm
1 4 3 8 1 2
dimensions strainer dimensions in. A mm in. B mm in. C mm in. D mm E (LF) in. mm F in. mm G in. mm H in. mm M in. mm N in. mm
241 67/8 175 241 67/8 175 241 67/8 175 307 77/16 188 368 8 202 461 117/16 290 476 117/16 290 535 121/16 307
73 123/8 314 73 123/8 314 73 123/4 324 88 151/2 393 98 193/16 487 129 231/4 591 129 251/16 637 142 2813/16 732
53/4 146 53/4 146 53/4 146 711/16 195 93/16 233 1111/16 297 1111/16 297 133/8 340
3 75 31/3 84 33/8 86 35/8 92 4 102 51/8 130 55/8 143 515/16 151
35 44 48 52 62 67 79 87
40 40 40 40 40 64 64 64
60 60 70 41 54 64 76 90
21/2 64 21/2 64 21/4 57 33/16 81 33/4 95 47/16 113 47/8 124 515/16 151
5.8 2.6 5.8 2.6 5.8 2.6 8.3 3.7 11.8 5.4 22.3 10.1 28.3 12.8 37.3 16.9
6.3 2.9 6.3 2.9 6.3 2.9 10.0 4.5 13.8 6.3 26.3 11.9 32.0 14.5 45.0 20.4
D A C
B M
G F
U919QT, U919QT-S
Size (dn) in. mm in.
3/4 20 1 25 11/4 32 11/2 40 2 50
dimensions strainer dimensions A mm in. B mm C in. mm D in. mm E (LF) in. mm F in. mm in. G mm in. H mm in. M mm in. N mm
1615/16 430 171/8 435 2015/16 532 219/16 547 2415/16 633
52 62 67 79 87
40 40 64 64 64
41 54 64 76 90
C D D
B E A
E A
G F
919AQT,919ZQT
Size (dn) in.
3 4
dimensions A B mm in. mm in. C mm in. D mm in. E (LF) in. mm F in. mm in. G mm in. H mm
mm
/ 1 11/4 11/2 2
20 25 32 40 50
52 62 67 79 87
40 40 64 64 64
Capacities
kPa psi 138 20
14
" (5 mm)
1" (25mm)
Pressure Loss
103 15
Pressure Loss
69 34 0
10 5 0 0 0 .25 .9 .5 1.9 .75 2.8 1 3.8 1.25 4.7 1.5 gpm 5.7 lpm
Flow Rate
Flow Rate
kPa psi 138 20
38
" (8 mm)
114" (32mm)
Pressure Loss
69 34 0
10 5 0 0 0 .5 1.9 1 3.8 1.5 5.7 2 7.6 2.5 9.5 3 11.4 3.5 13.2 4 15.1 4.5 gpm 17.0 lpm
Pressure Loss
103 15
138 20 103 15 69 34 0 10 5 0 0 0 10 38 20 76 30 114 40 152 50 190 60 228 70 266 80 gpm 304 lpm
Flow Rate
Flow Rate
kPa psi 172 25
12
112" (40mm)
Pressure Loss
Pressure Loss
138 20 103 15 69 34 0 10 5 0 0 0 2.5 9.5 5 17.0 7.5 28.4 10 38 12.5 47 15 gpm 57 lpm
103 15 69 34 0 10 5 0 0 0 20 76 40 152 60 228 80 304 100 380 120 gpm 456 lpm
Flow Rate
Flow Rate
34
" (20mm)
2" (50mm)
Pressure Loss
Flow Rate
30 114
40 152
Pressure Loss
0 0
50 190
Flow Rate
100 380
150 570
USA: No. Andover, MA Tel. (978) 688-1811 Fax: (978) 794-1848 www.watts.com Canada: Burlington, ONT. (905) 332-4090 Fax: (905) 332-7068 www.wattscanada.ca
ES-919 1103
2011 Watts