TR-CON-Q0604-Foreman Electrical Works Construction
TR-CON-Q0604-Foreman Electrical Works Construction
TR-CON-Q0604-Foreman Electrical Works Construction
The language of the compared competencies of the two countries differs. However, the
competency pointers of the described competency can be mapped. Wherever the
competency pointer maps it is reported as ‘None’ underthe column ‘Gap in Indian NOS’.
Wherever the competency pointers do not map with the pointers or scope and range, it is
identified as a gap and the corresponding UK competency is noted under the column ‘Gap
in Indian NOS’.
1
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
2
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
3
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
4
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
recognised working
practices, the working
environment and the
natural
environment. They
must know and
understand the
different types of
limitations, applications
and the techniques for
the positioning, fitting,
fixing and
connection of the
enclosures, their
components and
accessories.
5
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Competency Mapping: Thefollowingtable, the Indian NOS maps with the UK NOS SUMET04
‘Install enclosures for electrical cables, conductors and wiring systems’ UK NOS.
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
PC6. monitor and ensure wall P6 determine at the outset, that None
chasing work as per standard the plans for positioning and
procedure prior to laying fixing the components and
accessories of the selected
6
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
PC10. carry out or inspect P10 measure and mark out the None
electrical isolation at the main locations for fitting and fixing
and secondary power source as the selected enclosures
per standard procedure and components and accessories in
ensure work safety prior to accordance with:
conducting maintenance to P10.1 the electrical system’s
electrical wiring or pre-installed design
units P10.2 manufacturers’
instructions
PC11. fix complex electrical P11 fit, fix and connect the None
fixtures, installs fire alarm selected enclosures its
systems as per requirement components and accessories in
accordance with:
P11.1 the electrical system’s
design
P11.2 industry recognised
methods
P11.3 manufacturers’
7
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
instructions
PC12. conduct/ carry out P12 confirm with the relevant None
earthing of installed electrical people:
circuit as per standard method P12.1 those necessary variations
and using standard earthing to the planned programme of
components work that may have the
potential to introduce a hazard
and/or impact on the
installation work to be
undertaken
P12.2 the correct actions to be
undertaken to ensure that any
variations to the planned
programme of work will not
introduce a hazard and have
minimum impact on the
installation work to be
undertaken
8
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
KA4. how to request for tools K4 how to verify that job None
and materials as per set information and documentation
procedures maintenance of is current and relevant and that
tools and equipment the plant, instruments, access
equipment and tools are fit for
purpose
9
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
KB7. how to estimate required K11 the correct procedures for None
material quantity from electrical safe isolation
drawings
10
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
undertaken
KB9. how to verify K13 the methods for the safe None
authentication of ISI mark transport and/or disposal of
provided with electrical waste material, substances and
materials, fixtures and devices liquids in accordance with
suppliers’ and manufacturers’
instructions
11
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
General Note: In the Construction SSC NOS, Range statement is not separated out. It is integrated
holistically into the PCs and knowledge within the QPs
12
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
13
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
the specification,
industry recognised
working practices, the
working
accessories and
components, their
limitations, applications
and the techniques
14
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Competency Mapping: Thefollowingtable, the Indian NOS maps with the UK NOS SUMET05
‘Install and connect electrical cables, conductors, wiringsystems and equipment’ UK NOS.
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
15
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
PC7. conduct conduit laying for P7 identify the correct means of None
RCC structures and ensure electrical isolation prior to
specification of conduits are as commencing installation and
per requirement connection work
PC10. carry out or inspect P10 check that the connections None
electrical isolation at the main and joints of the electrical
and secondary power source as cables, conductors and wiring
per standard procedure and systems and their associated
ensure work safety prior to equipment, accessories and
conducting maintenance to components are of proper
electrical wiring or pre-installed construction as regards to
units conductance, insulation,
mechanical strength and
protection, and ensure that they
are identified correctly and
16
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
PC11. fix complex electrical P11 confirm with the relevant None
fixtures, installs fire alarm people:
systems as per requirement P11.1 those necessary variations
to the planned programme of
work that may have the
potential to introduce a hazard
and/or impact on the
installation work to be
undertaken
P11.2 the correct actions to be
taken to ensure that any
variations to the planned
programme of work will not
introduce a hazard and have
minimum impact on the
installation to be undertaken
17
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
KA4. how to request for tools K4 how to verify that job None
and materials as per set information and documentation
procedures maintenance of is current and relevant, and that
tools and equipment the plant, instruments, access
equipment and tools are fit for
18
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
purpose
19
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
accordance with:
K10.1 the electrical system’s
design
K10.2 manufacturers’
instructions
KB7. how to estimate required K11 the different types and None
material quantity from electrical methods of joining and
drawings connecting electrical cables,
conductors, wiring systems,
their applications, advantages
and limitations
KB10. principles of electrical K14 the methods for the safe None
theory as applied to electrical transport and/or disposal of
circuits and wiring systems waste material, substances and
liquids in accordance with
suppliers’ and manufacturers’
instructions
20
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
21
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
General Note: In the Construction SSC NOS, Range statement is not separated out. It is integrated
holistically into the PCs and knowledge within the QPs
22
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
23
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
identification and
use of the correct
instruments
completion of the
relevant
documentation
recording of
relevant data and
information.
Competency Mapping: Thefollowingtable, the Indian NOS maps with the UK NOS SUMET06
‘Inspect and test electrical systems and equipment’ UK NOS.
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
24
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
25
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
PC11. erect electrical panel as P11 perform the tests in the None
power source if required and correct sequence that ensure
get it activated safe and efficient operation of
the electrical system
PC12. conduct and carry out P12 comply with organisational None
electrical connection works procedures for:
between machinery and power completion of the relevant
source documentation
P12.2 the recording of relevant
data and information
P12.3 informing relevant
people
P12.4 addressing issues and
problems
26
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
27
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
28
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
KB6. how to develop electrical K10 the correct procedures for None
drawings using appropriate safe-isolation
symbols and abbreviations as
per standard practice
KB7. how to estimate required K11 the methods and processes None
material quantity from electrical to carry out correctly the tests
drawings that ensure safe and efficient
operation of the electrical
system
29
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
30
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
3 phase connections
KB19. operational
characteristics of electrical
panels and power distribution
through the same
31
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
General Note: In the Construction SSC NOS, Range statement is not separated out. It is integrated
holistically into the PCs and knowledge within the QPs
32
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
33
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
identification and
use of the correct
instruments
completion of the
relevant
documentation
recording of
relevant data and
information
identification and
consideration of
the customer’s
need for electrical
systems and
equipment
configuration
planning of the
resources required
to carry out the
commissioning
process
34
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Competency Mapping: Thefollowingtable, the Indian NOS maps with the UK NOS SUMET07
‘Commission electrical systems and equipment’ UK NOS.
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
35
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
36
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
PC24. prepare data sheet, P11 ensure that the results are None
report and note readings as per recorded in the appropriate
applicability according to information systems and passed
organizational procedures to the relevant people
37
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
PC22. ensure occurrence of trial P12 ensure that the electrical None
run and obtain clearance from system and equipment is ready
respective authority relevant to for hand over to the
electrical works prior to leave customer/client
any equipment for working
SA3. record and document P13 identify and explain any None
key details during the related variations
works like actual and expected
outcomes, deviations from
tolerance levels, etc.
SA4. prepare basic status
updates for the supervisor in
the prescribed format as per
the requirements of the client /
contractor
38
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
39
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
40
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
41
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
unavailable
42
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
contractor
General Note: In the Construction SSC NOS, Range statement is not separated out. It is integrated
holistically into the PCs and knowledge within the QPs
43
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
44
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
identification and
use of the correct
instruments
completion of the
relevant
documentation
recording of
relevant data and
information
identification and
consideration of
the customer’s
need for electrical
systems and
equipment
configuration
planning of the
resources required
to carry out the
commissioning
process
45
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Competency Mapping: Thefollowingtable, the Indian NOS maps with the UK NOS SUMET07
‘Commission electrical systems and equipment’ UK NOS.
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
46
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
47
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
48
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
PC20. prepare field reports, P11 ensure that the results are None
hand sketches etc. as and when recorded in the appropriate
necessary for documentation of information systems and passed
related works to the relevant people
PC16. conduct trial run and P12 ensure that the electrical None
required tests to ensure safe system and equipment is ready
working of plant and for hand over to the
machineries customer/client
49
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
SA3. record and document P13 identify and explain any None
key details during the related variations
works like actual and expected
outcomes, deviations from
tolerance levels, etc.
50
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
KB19. operational
characteristics of electrical
panels and power distribution
through the same
51
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
organizational policy,
procedure of providing CPR,
first aids, use of regular and job
specific PPEs as per
requirement
52
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
KB21. advance
troubleshooting in electrical
panels, transformers and
generators
53
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
KB33. calibration of
equipment and authorization
procedures as per the
organization policy
54
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
General Note: In the Construction SSC NOS, Range statement is not separated out. It is integrated
holistically into the PCs and knowledge within the QPs
55
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
56
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
the identification
and use of the
correct instruments
how to identify and
locate faults
how to rectify the
faults that are
identified, located
and diagnosed
the completion of
the relevant
documentation
the recording of
relevant data and
information.
57
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Competency Mapping: Thefollowingtable, the Indian NOS maps with the UK NOS SUMET08
‘Identify and rectify faults in electrical systems and equipment’ UK NOS.
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
To be competent, the You must be able to-
user/individual on the job
must be able to-
PC3. inspect completed LV P1 obtain clear and detailed
electrical arrangements for information about the reported
conformance with fault(s) and any components
specifications, requirements which need to be replaced
and compliance with applicable from relevant:
statutory and HSE P1.1 sources of information
requirements P1.2 documentation"
PC5. conduct periodical checks/
tests to insulation, joints,
physical condition and
termination of wires and cables
to ensure safe working of
wiring systems
PC6. check condition and safety
of isolation and ensure safe
condition for undertaking
maintenance/ repairing in
wires, cables, lights and fixtures
PC7. diagnose malfunctioning
of wiring systems, circuits,
temporary panels and its
components, using appropriate
measuring equipment and
hand tools
P2 advise the relevant None
people clearly and accurately
about the potential disruption
and consequences of carrying
out the processes and
procedures for the
identification and rectification
of faults
CON/N0612: Establish electrical P3 confirm a programme of
connections during erection of work with the relevant people
plant and heavy construction in accordance with
machineries organisational procedures
PC6. check condition and safety P4 determine and obtain
of isolation and ensure safe the resources required, as
condition for undertaking relevant, to undertake:
58
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
maintenance/ repairing in P4.1 the identification and
wires, cables, lights and fixtures location of the fault(s)
PC7. diagnose malfunctioning P4.2 the rectification of the
of wiring systems, circuits, fault(s)"
temporary panels and its
components, using appropriate
measuring equipment and
hand tools
PC8. carry out troubleshooting
and take immediate actions in
case of emergency repairing
requirements related to short
circuit or malfunction in wiring
systems, temporary electrical
panels or lighting arrangements
PC7. diagnose malfunctioning P5 select the instruments to
of wiring systems, circuits, be used
temporary panels and its
components, using appropriate
measuring equipment and
hand tools
PC9. ensure proper functioning
of power tools and diagnostic
tools by conducting
maintenance as per
manufacturer’s guidelines at
scheduled intervals
PC12. adhere to schedule of P6 confirm that the
calibration (if any) and conduct instruments are fit for purpose
calibration periodically to and have a current calibration
ensure correct working of certificate the fault
testing equipment and ensure identification and rectification
removal of faulty ones from process
worksite
PC6. check condition and safety P7 identify the correct
of isolation and ensure safe means of electrical isolation
condition for undertaking prior to commencing
maintenance/ repairing in
wires, cables, lights and fixtures
PC13. check condition and
safety of isolation and ensure
safe condition for undertaking
maintenance/ repairing in
construction equipments
P8 complete safe-isolation
59
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
as and when required to ensure
the safe fault
identification and rectification
in electrical cables, conductors
and/or wiring system and the
associated equipment,
accessories and components
PC2. check and ensure P9 comply with industry
materials, fixtures and devices practices and organisational
being used in repairing or procedures to ensure the co-
maintenance works are ISI ordination of site services and
certified the activities of other trades
PC4. check & ensure that affected by:
lighting arrangements and its P9.1 the identification and
components are in safe location of the fault(s)
condition working properly P9.2 the rectification of the
PC5. conduct periodical checks/ fault(s)
tests to insulation, joints,
physical condition and
termination of wires and cables
to ensure safe working of
wiring systems
PC8. carry out troubleshooting
and take immediate actions in
case of emergency repairing
requirements related to short
circuit or malfunction in wiring
systems, temporary electrical
panels or lighting arrangements
PC1. ensure that preventive P10 identify, locate, diagnose
maintenance of electrical and rectify faults
wiring, equipment and fixtures
deployed at construction works
is being carried out regularly as
per requirement
PC3. inspect completed LV
electrical arrangements for
conformance with
specifications, requirements
and compliance with applicable
statutory and HSE
requirements
PC5. conduct periodical checks/
tests to insulation, joints,
physical condition and
60
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
termination of wires and cables
to ensure safe working of
wiring systems
PC7. diagnose malfunctioning
of wiring systems, circuits,
temporary panels and its
components, using appropriate
measuring equipment and
hand tools
PC8. carry out troubleshooting P11 repair, remove and
and take immediate actions in replace in accordance with
case of emergency repairing industry recognised methods
requirements related to short and procedures, as
circuit or malfunction in wiring appropriate:
systems, temporary electrical P11.1 electrical cables,
panels or lighting arrangements conductors and/or wiring
PC14. conduct installation, system
electrical maintenance and P11.2 equipment, accessories
repair of equipment like and components
electrical distribution panels
and its accessories, common
construction equipment like
bar cutting/bending machine,
different types of common
pumps used in construction
sites, transformers and tower
cranes
PC19. ensure erection of safety P12 ensure, if the fault(s)
signage and barricading, cannot be corrected
surrounding the faulty or immediately, the safety of the
electrically hazardous relevant:
equipment/ locations to avoid P12.1 electrical cables,
unsafe conditions conductors and/or wiring
PC25. ensure electrical safety system
to workers, equipment, P12.2 equipment, accessories
materials and fixtures by and components
adopting standard safe working
procedures as per
organizational norms, at
workplace
61
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
certified repaired and/or replaced:
PC3. inspect completed LV P13.1 electrical cables,
electrical arrangements for conductors and/or wiring
conformance with system
specifications, requirements P13.2 equipment, accessories
and compliance with applicable and components
statutory and HSE
requirements
PC7. diagnose malfunctioning
of wiring systems, circuits,
temporary panels and its
components, using appropriate
measuring equipment and
hand tools
PC15. ensure proper
termination of cables as per
applicability at power source
and equipment
PC21. ensure proper earthing
of electrical circuits as per
relevant specifications or
manufacturer’s guidelines
PC22. ensure occurrence of P14 provide clear and
trial run and obtain clearance accurate information to
from respective authority relevant people about the
relevant to electrical works electrical system and
prior to leave any equipment equipment in terms of:
for working P14.1 hand over to the
PC24. prepare data sheet, customer/client
report and note readings as per P14.2 any variations to the
applicability according to original system and/or its
organizational procedures equipment
P14.3 customer/client
acceptance of the completed
work in accordance with
organisational procedures
P14.4 relevant documentation
being completed and recorded
in the appropriate information
systems in accordance with
organisational procedures
62
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
63
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
64
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
65
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
66
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
67
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
General Note: In the Construction SSC NOS, Range statement is not separated out. It is integrated
holistically into the PCs and knowledge within the QPs
68
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
69
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
70
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Competency Mapping: Thefollowingtable, the Indian NOS maps with the UK NOS SUMET08
‘Identify and rectify faults in electrical systems and equipment’ UK NOS.
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
71
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
as built drawing
72
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
73
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
74
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
75
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
76
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
77
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
K9.2 equipment,
accessories and components
SB16. evaluate the complexity "K12 how to provide clear and None
of the task and seek assistance accurate information to relevant
and support wherever people about the electrical
system and equipment in terms
78
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
required of:
K12.3 customer/client
acceptance of the completed
work in accordance with
organisational procedures
K12.4 relevant
documentation being
completed and recorded in the
appropriate information
systems in accordance with
organisational procedures"
General Note: In the Construction SSC NOS, Range statement is not separated out. It is integrated
holistically into the PCs and knowledge within the QPs
79
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Section II:Compares the competencies in Indian NOS Manage workplace for safe and
healthy work environment (CON/Q9002) with those of UK NOS Apply health and safety and
environmental legislation in the building services engineering sector (SUMBSE01).
Indian NOS Manage workplace for UK NOS Apply health and safety
safe and healthy work and environmental
environment legislation in the
building services
engineering sector
80
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
81
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Competency Mapping: Thefollowingtable, the Indian NOS maps with the UK NOS SUMBSE01
‘Apply health and safety and environmental legislation in the building services engineering
sector’ UK NOS.
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
PC3. ensure that health and P3 identify hazards and risks None
safety plan is followed by all
subordinates
PC5. ensure that all safety and P5 review the organisational None
protection installation are procedures to ensure that they
correctly placed & adequate will not cause potential hazards
and risks
PC7. ensure safe use of tools P7 report to the relevant people None
and tackles by the workmen as in accordance with
per applicability organisational procedures:
82
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
83
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
84
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
85
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
General Note: In the Construction SSC NOS, Range statement is not separated out. It is integrated
holistically into the PCs and knowledge within the QPs
86
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
This standard is
87
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
• respond as
appropriate to client
and customer needs
and expectations
Competency Mapping: Thefollowingtable, the Indian NOS maps with the UK NOS SUMBSE02
‘Establish and maintain relationships in the building services engineering sector’ UK NOS.
88
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
89
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
satisfactory condition
P6.3 the hand over process
90
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
91
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
92
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
General Note: In the Construction SSC NOS, Range statement is not separated out. It is integrated
holistically into the PCs and knowledge within the QPs
93
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Indian NOS Plan and organize work UK NOS Establish and maintain
to meet expected relationships in the
outcomes building services
engineering sector
This standard is
94
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
• respond as
appropriate to client
and customer needs
and expectations
Competency Mapping: Thefollowingtable, the Indian NOS maps with the UK NOS SUMBSE02
‘Establish and maintain relationships in the building services engineering sector’ UK NOS.
95
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
96
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
satisfactory condition
P6.3 the hand over process
PC10. employ tools, tackles and P10 comply with organisational None
equipment with care to avoid standards for appearance and
damage to the same behaviour
97
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
98
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
99
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
General Note: In the Construction SSC NOS, Range statement is not separated out. It is integrated
holistically into the PCs and knowledge within the QPs
100
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
This standard is
101
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
• respond as
appropriate to client
and customer needs
and expectations
Competency Mapping: Thefollowingtable, the Indian NOS maps with the UK NOS SUMBSE02
‘Establish and maintain relationships in the building services engineering sector’ UK NOS.
102
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
103
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
engineering system is in a
satisfactory condition
P6.3 the hand over process
104
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
105
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
maintained importance of
providing technical and
functional information clearly,
courteously and professionally
106
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
General Note: In the Construction SSC NOS, Range statement is not separated out. It is
integrated holistically into the PCs and knowledge within the QPs
107
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
108
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
• respond as
appropriate to client
and customer needs
and expectations
Competency Mapping: Thefollowingtable, the Indian NOS maps with the UK NOS SUMBSE02
‘Establish and maintain relationships in the building services engineering sector’ UK NOS.
109
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
PC5. ensure that all safety and P5 demonstrate to the clients None
protection installation are and customers, as appropriate,
correctly placed & adequate the operation of the building
services engineering system that
has been installed and/or
maintained
110
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
satisfactory condition
P6.3 the hand over process
111
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
reporting
stooping work
evacuation
fire risks and safe exit
procedures
112
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
113
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
114
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
provided
General Note: In the Construction SSC NOS, Range statement is not separated out. It is
integrated holistically into the PCs and knowledge within the QPs
115
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
116
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
• the work to be
undertaken
• a programme of work
with relevant people
• the organisation of
the appropriate
resources
• that equipment,
accessories and
components are fit-for-
purpose
• all relevant
documentation is
completed accurately
117
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Competency Mapping: Thefollowingtable, the Indian NOS maps with the UK NOS SUMBSE03
‘Coordinate a work site in the building services engineering sector’ UK NOS.
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
PC4. observe and verify the P4 confirm that any instructions None
work activities performed by the given are understood
subordinates at the construction
118
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
site
119
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
120
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
121
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
General Note: In the Construction SSC NOS, Range statement is not separated out. It is
integrated holistically into the PCs and knowledge within the QPs
122
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
123
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
• the work to be
undertaken
• a programme of work
with relevant people
• the organisation of
the appropriate
resources
• that equipment,
accessories and
components are fit-for-
purpose
• all relevant
documentation is
completed accurately
124
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Competency Mapping: Thefollowingtable, the Indian NOS maps with the UK NOS SUMBSE03
‘Coordinate a work site in the building services engineering sector’ UK NOS.
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
125
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
PC4. check & ensure that P4 confirm that any instructions None
lighting arrangements and its given are understood
components are in safe
condition working properly
126
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
PC10. develop hand sketches P10 verify that the equipment, None
relevant to electrical circuit accessories and components
diagrams using standard wiring are:
symbols as per work P10.1 compatible to the working
requirements environment
P10.2 in accordance with the
specification
P10.3 of the required and
correct type
P10.4 delivered on time and
undamaged
P10.5 suitable and safely stored
127
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
128
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Performance Criteria - Indian Performance Criteria - UK NOS Gaps w.r.t to Scope and Range
NOS in Indian NOS
129
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
130
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
documentation
K6.2 agreeing a programme of
work with relevant people
K6.3 confirming that the
installation and/or maintenance
work is completed
K6.4 identification of
competence
KB3. electrical safety norms as K7 methods that will verify that None
per standard practice and the equipment, accessories and
organizational policy, procedure components are:
of providing CPR, first aids, use K7.1 compatible to the working
of regular and job specific PPEs environment
as per requirement K7.2 in accordance with the
specification
K7.3 of the required and correct
type
K7.4 delivered on time and
undamaged
K7.5 suitable and safely stored
131
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
construction works
132
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
KB20. operational
characteristics of electrical
panels and power distribution
through the same
133
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
SB3. identify safety risks that K17 what the programme is for
affect the health, safety and the work to be carried out in the
environment for self and others estimated, allocated time and
working in the vicinity, tackle it why deadlines should be kept
if within limit or report to
appropriate authority
General Note: In the Construction SSC NOS, Range statement is not separated out. It is
integrated holistically into the PCs and knowledge within the QPs
134
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Competency Mapping: Thefollowingtable, the Indian NOS maps with the UK NOS COSVR166
‘Cut and bend reinforcement steel to shape’ UK NOS.
Performance Criteria - Indian Performance Criteria - UK NOS Gaps in Indian NOS
NOS
To be competent, the You must be able to-
user/individual on the job
must be able to-
P1,Intrepet the given w.r.t Scope /Range of P1:
information relating to the interpretations of
SA2. read in one or more work and to resources to specifications, schedules, risk
language, preferably the local confirm its relevance assessment, manufactures
language at the site read information
SA5. read various, sign boards,
safety rules and safety tags,
instruction related to exit
routes during emergency at the
workplace
135
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
136
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
K1 the organisational
procedures developed to
report and rectify
inappropriate information
and unsuitable resources,
and how they are
implemented
137
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
138
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
General Note: In the Construction SSC NOS, Rangestatement is not separated out. It is integrated
holistically into the PCs andknowledge within the QPs
139
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Section II continued: Compares the competencies in Indian NOS Read and understand
routine drawings / sketches and Bar Bending Schedule (CON/N0204)with the UK NOSFix steel
in situ(COSVR534).
NOS Mapping Descriptions
Indian QP Title Bar Bender & Steel Fixer UK Qualification Steel fixer
Indian NOS Read and understand UK Unit Title Fix steel in situ
routine drawings / sketches
and Bar Bending Schedule
140
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Competency Mapping: Thefollowingtable, the Indian NOS maps with the UK NOS COSVR534
‘Fix steel in situ ’ UK NOS.
Performance Criteria - Indian Performance Criteria - UK NOS Gaps in Indian NOS
NOS
To be competent, the You must be able to-
user/individual on the job
must be able to-
PC1. select hand tools/power P1,Intrepet the given interpretations of
tools for cutting rebars as per information relating to the specifications, schedules, risk
requirement / instruction work and to resources to assessment and manufacturers
confirm its relevance information
PC8. select hand/power tools
for bending rebars with respect
to the work
141
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
K1 the organisational
procedures developed to
report and rectify
inappropriate information
and unsuitable resources,
and how they are
implemented
142
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
143
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
reinforcement
KA2. safety rules and K12 the hazards associated with None
regulations for handling and the resources and methods of
storing required tools, work and how they are
equipment and materials overcome
General Note: In the Construction SSC NOS, Rangestatement is not separated out. It is integrated
holistically into the PCs andknowledge within the QPs
144
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Section II continued: Compares the competencies in Indian Prepare, fabricate, place and
fix reinforcement for RCC structures (CON/N0206)with the UK NOSFix steel in situ(COSVR534).
Indian NOS Prepare, fabricate, place UK Unit Title Fix steel in situ
and fix reinforcement for
RCC structures
Competency Mapping: Thefollowingtable, the Indian NOS maps with the UK NOS COSVR534
‘Fix steel in situ ’ UK NOS.
Performance Criteria - Indian Performance Criteria - UK NOS Gaps in Indian NOS
NOS
145
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
CON/N9001:Work according to
personal health, safety and
environment protocol at
construction site
PC3. select rebars for P3: select the required quantity None
placement as per the drawing and quality of resources for the
methods of work
CON/N0205: Use hand and power
tools for cutting and bending of
reinforcement
CON/N9001:Work according to P4: comply with organisational Protection of the work and its
personal health, safety and procedures to minimise the risk surrounding area from
environment protocol at of damage to the work and damage
construction site surrounding area
PC4. mark and place rebars, P5: comply with the given None
fabricate cage and fix on its contract information to carry out
position as per the drawing the work efficiently to the
required specification
PC5. maintain uniform spacing
between the bars, stirrups, link
rod as per the drawing
146
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
SB4. complete work as per P6: complete the work within the None
agreed time schedule and quality allocated time, in accordance
with the programme of work
K1 the organisational
procedures developed to
report and rectify
inappropriate information
and unsuitable resources,
and how they are
implemented
147
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
wherever required
148
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
KB15. electrical safety of powers K12 the hazards associated with None
tools and equipments used in bar the resources and methods of
bending works work and how they are overcome
149
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
should be kept
General Note: In the Construction SSC NOS, Rangestatement is not separated out. It is integrated
holistically into the PCs andknowledge within the QPs
150
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Section II continued: Compares the competencies in Indian NOS Read and understand
routine drawings / sketches and Bar Bending Schedule (CON/N0204)with the UK
NOSPrefabricate reinforcement steel sections (COSVR535).
NOS Mapping Descriptions
Indian QP Title Bar Bender & Steel Fixer UK Qualification Steel fixer
4 prefabricating reinforcing
steel for concrete
structures
151
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Competency Mapping: Thefollowingtable, the Indian NOS maps with the UK NOS COSVR535
‘Prefabricate reinforcement steel sections’ UK NOS.
Performance Criteria - Indian Performance Criteria - UK NOS Gaps in Indian NOS
NOS
152
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
CON/N9001:Work according to P4: comply with organisational protection of the work and
personal health, safety and procedures to minimise the risk its surrounding area from
environment protocol at of damage to the work and damage
construction site surrounding area
CON/N0205: Use hand and power P5: comply with the given None
tools for cutting and bending of contract information to carry out
reinforcement the work efficiently to the
CON/N0206: Prepare, fabricate, required specification
place and fix reinforcement for
RCC structures
PC7. plan for cutting of rebars as P6: complete the work within the None
per instructions allocated time, in accordance
with the programme of work
PC12. plan for cutting of rebars as
per instructions, considering
minimum wastage and cutting
length
K1 the organisational
procedures developed to
report and rectify
inappropriate information
and unsuitable resources,
and how they are
implemented
153
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
154
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
General Note: In the Construction SSC NOS, Rangestatement is not separated out. It is integrated
holistically into the PCs andknowledge within the QPs
155
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Section II continued: Compares the competencies in Indian NOS Prepare, fabricate, place
and fix reinforcement for RCC structures (CON/N0206) with the UK NOS Prefabricate
reinforcement steel sections(COSVR535).
NOS Mapping Descriptions
Indian QP Title Bar Bender & Steel Fixer UK Qualification Steel fixer
156
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
Competency Mapping: Thefollowingtable, the Indian NOS maps with the UK NOS COSVR535
‘Prefabricate reinforcement steel sections’ UK NOS.
Performance Criteria - Indian Performance Criteria - UK NOS Gaps in Indian NOS
NOS
CON/N9001:Work according to
personal health, safety and
environment protocol at
construction site
PC3. select rebars for P3: select the required quantity None
placement as per the drawing and quality of resources for the
methods of work
CON/N0205: Use hand and power
tools for cutting and bending of
reinforcement
CON/N9001:Work according to P4: comply with organisational Protection of the work and
personal health, safety and procedures to minimise the risk its surrounding area from
environment protocol at of damage to the work and damage
construction site surrounding area
PC4. mark and place rebars, P5: comply with the given lifting points
fabricate cage and fix on its contract information to carry out
position as per the drawing the work efficiently to the
required specification
PC5. maintain uniform spacing
between the bars, stirrups, link
157
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
SB4. complete work as per P6: complete the work within the None
agreed time schedule and quality allocated time, in accordance
with the programme of work
158
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
K1 the organisational
procedures developed to
report and rectify
inappropriate information
and unsuitable resources,
and how they are
implemented
159
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
KB15. electrical safety of powers K12 the hazards associated with None
tools and equipments used in bar the resources and methods of
bending works work and how they are overcome
160
TRANSNATIONAL SKILL STANDARDS FOR CONSTRUCTION INDUSTRY
General Note: In the Construction SSC NOS, Rangestatement is not separated out. It is integrated
holistically into the PCs andknowledge within the QPs
161