IECEx Certificate

of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION
IEC Certification Scheme for Explosive Atmospheres
for rules and details of the IECEx Scheme visit www.iecex.com

Certificate No.: IECEx SIR 09.0028 Issue No: 2 Certificate history:


Issue No. 2 (2011-04-26)
Status: Current Issue No. 1 (2011-04-06)
Page 1 of 4 Issue No. 0 (2010-01-04)
Date of Issue: 2011-04-26

Applicant: Petrel Limited


Fortnum Close
Kitts Green
Birmingham B33 0LB
United Kingdom

Equipment: 620 Wellglass & 621 Bulkhead Luminaires


Optional accessory:

Type of Protection: Flameproof, Increased Safety and Dust

Marking: EEx de IIB T* or EEx de IIC T*


Ex tb III C T* °C Db IP66
Ta = -20 °C to +* °C
(* The temperature classification and maximum surface temperature for dust are dependent upon the maximum ambient
temperature and the type of light source used, refer to Equipment Description)

Approved for issue on behalf of the IECEx C Ellaby


Certification Body:

Position: Certification Officer

Signature:
(for printed version)

Date:

1. This certificate and schedule may only be reproduced in full.


2. This certificate is not transferable and remains the property of the issuing body.
3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website.

Certificate issued by:


SIRA Certification Service
Rake Lane
Eccleston
Chester
CH4 9JN
United Kingdom
IECEx Certificate
of Conformity
Certificate No: IECEx SIR 09.0028 Issue No: 2

Date of Issue: 2011-04-26


Page 2 of 4

Manufacturer: Petrel Limited


Fortnum Close
Kitts Green
Birmingham B33 0LB
United Kingdom

Additional Manufacturing location(s):

This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the
IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and
found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme
Rules, IECEx 02 and Operational Documents as amended.

STANDARDS:
The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found
to comply with the following standards:

IEC 60079-0 : 2007-10 Explosive atmospheres - Part 0:Equipment - General requirements


Edition:5
IEC 60079-1 : 2007-04 Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d"
Edition:6
IEC 60079-7 : 2006-07 Explosive atmospheres - Part 7: Equipment protection by increased safety "e"
Edition:4
IEC 61241-1 : 2004 Electrical apparatus for use in the presence of combustible dust - Part 1: Protection by enclosures "tD"
Edition:1

This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the

Standards listed above.

TEST & ASSESSMENT REPORTS:


A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in

Test Report:

GB/SIR/ExTR09.0181/00 GB/SIR/ExTR10.0183/00 GB/SIR/ExTR11.0084/00

Quality Assessment Report:

GB/SIR/QAR08.0014/01 GB/SIR/QAR08.0014/02
IECEx Certificate
of Conformity
Certificate No: IECEx SIR 09.0028 Issue No: 2

Date of Issue: 2011-04-26


Page 3 of 4

Schedule

EQUIPMENT:
Equipment and systems covered by this certificate are as follows:

The 620 Wellglass and 621 Bulkhead Luminaires consist of a housing manufactured in aluminium, gunmetal or stainless
steel, which includes a separate lid incorporating a glass dome.   The shape of this glass dome is the only distinguishing
feature between the 620 and 621 luminaires.   The glass dome is cemented into the lid using Eccobond 45LV.   Within the
enclosure are housed the optional light sources and any associated electrical equipment.   Electrical connection is made
via an increased safety terminal housing.   This is cast, as part of the same main housing.   The terminal housing employs
component-approved terminals, interconnection between the terminals and the flameproof housing is via a component
approved bushing.

The luminaires are available with either a spigot joint (IIB applications) or a threaded joint (IIC applications) between the
base and the glass lid collar.   The temperature classes, ambient temperatures and time delays that are applicable to each
light source are listed in the Annexe

SPECIFIC CONDITIONS OF USE: NO


IECEx Certificate
of Conformity
Certificate No: IECEx SIR 09.0028 Issue No: 2

Date of Issue: 2011-04-26


Page 4 of 4

DETAILS OF CERTIFICATE CHANGES (for issues 1 and above):

Issue 1 – this Issue introduced the following changes:


1 The recognition that the 620 and 621 Wellglass Luminaires
may be fitted with alternative bulbs.  These are listed in the
Annexe.
Issue 2 – this Issue introduced the following changes:
1 The recognition that the 620 and 621 Wellglass Luminaires
may be fitted with alternative bulbs.  These are listed in the
Annexe.

Annex:

IECEx SIR 09.0028_Iss2 Annexe.pdf


Annexe to: IECEx SIR 09.0028 Issue 2

Applicant: Petrel Limited

Apparatus: 620 Wellglass and 621 Bulkhead Luminaires


CERTIFICATION
Type 620 T-Class Ambient Time Delay T-Class Ambient Time Delay
300 W GLS T3 40°C 10 mins T3 55°C 10 mins
125 W HPMV T4 40°C 35 mins T3 60°C 35 mins
150 W SON T4 40°C 35 mins T3 60°C 35 mins
85 W QL T5 40°C 10 mins T4 60°C 10 mins
250 W HPMV T3 39°C 05 mins
250 W SON T3 40°C 05 mins
Type 621 T-Class Ambient Time Delay T-Class Ambient Time Delay
70 W SON T4 40°C 05 mins T4 60°C 05 mins
80 W HPMV T4 40°C 05 mins T3 60°C 05 mins
25 W SL T6 40°C 40 mins T5 60°C 40 mins
125 W HPMV T4 40°C 05 mins
200 W GLS T4 33°C 05 mins
When Modified Eccobond 45 LV, White is used.
Type 620 Temperature Class Ambient (°C) Time Delay (Mins)
250W SON T3 70 05
250W HPMV T2 65 05
250W HPMV T3 50 05
150W SON T3 90 35
125W HPMV T3 90 35
300W GLS T3 85 10
Type 621 Temperature Class Ambient (°C) Time Delay (Mins)
125W HPMV T3 70 05
70W SON T3 90 05
25W SL or PLCE T5 60 40
200W GLS T3 60 05
80W HPMV T3 90 05
Conditions of manufacture

The Manufacturer shall comply with the following condition of manufacture:


i. Each 620-glass dome shall be subjected to a routine overpressure test of 13.0 bar for at least 10 s as
required by clause 16.1 of IEC 60079-1. There shall be no permanent deformation or damage to the
enclosure.
ii. Each 621-glass dome shall be subjected to a routine overpressure test of 12.1 bar for at least 10 s as
required by clause 16.1 of IEC 60079-1. There shall be no permanent deformation or damage to the
enclosure.
iii. A 1500 Vrms electrical strength test shall be applied for at least 60 s in accordance with clause 6.1 of IEC
60079-7 between the live parts of the terminals and bushing and the outer case. The internal
components of the Ex d enclosure may be disconnected for this test. Alternatively, the test shall be
performed at 1.2 times this voltage and the duration shall be at least 100 ms in accordance with clause
7.1 of IEC 60079-7.
iv. The 620 Wellglass and 621 Bulkhead Luminaires covered by this certificate incorporate previously certified
devices, it is therefore the responsibility of the manufacturer to continually monitor the status of the
certification associated with these devices, and the manufacturer shall inform Sira of any modifications of
the devices that may impinge upon the explosion safety design of the 620 Wellglass and 621 Bulkhead
Luminaires

Sira Certification Service


Date: 11 April 2011 Page 1 of 2 Rake Lane, Eccleston, Chester, CH4 9JN, England
Tel: +44 (0) 1244 670900
Fax: +44 (0) 1244 681330
Form 9530 Issue 1
Email: info@siracertification.com
Web: www.siracertification.com
Annexe to: IECEx SIR 09.0028 Issue 2

Applicant: Petrel Limited

Apparatus: 620 Wellglass and 621 Bulkhead Luminaires


CERTIFICATION
Issue 1 introduced the following:
i. It was recognised that the 620 and 621 Wellglass Luminaires may be fitted with the following alternative
bulbs: (Note: the table shows the detail regarding Temperature Class, Maximum ambient and Time Delay.)
Luminaire Type Bulb T class Max ambient Time Delay
620 2x105W Halogen GLS T3 85°C 10 mins
620 2x100W Halogen GLS T3 85°C 10 mins
620 3x70W Halogen GLS T3 55°C 10 mins
620 2x70W Halogen H1 T3 100°C 10 mins
620 2x70W Halogen H1 T4 33°C 10 mins
620 2x70W Halogen GLS T3 100°C 10 mins
620 2x70W Halogen GLS T4 33°C 10 mins
620 105W Halogen GLS T3 100°C 10 mins
620 105W Halogen GLS T4 40°C 10 mins
620 100W Halogen GLS T3 110°C 10 mins
620 100W Halogen GLS T4 40°C 10 mins
620 85W SQL T5 40°C 10 mins
620 85W SQL T4 60°C 10 mins
620 100 W GLS T3 100°C 10 mins
620 100 W GLS T4 40°C 10 mins
620 70 W Halogen GLS T3 110°C 10 mins
620 70 W Halogen GLS T4 33°C 10 mins
621 2x70W Halogen GLS T3 90°C 10 mins
621 2x70W Halogen GLS T4 33°C 10 mins
621 70 W Halogen GLS T3 100°C 10 mins
621 70 W Halogen GLS T4 33°C 10 mins
Issue 2 introduced the following:
i. It was recognised that the 620 and 621 Wellglass Luminaires may be fitted with the following alternative
bulbs: (Note: the table shows the detail regarding Temperature Class, Maximum ambient and Time Delay.)
Luminaire Type Bulb T class Max ambient Time Delay
620 2x75W Halogen GLS T3 100°C 10 mins
620 2x75W Halogen GLS T4 33°C 10 mins
620 75 W Halogen GLS T3 110°C 10 mins
620 75 W Halogen GLS T4 33°C 10 mins
621 2x75W Halogen GLS (mounted horizontally) T3 90°C 10 mins
621 2x75W Halogen GLS (mounted vertically) T3 80°C 10 mins
621 2x75W Halogen GLS T4 33°C 10 mins
621 75 W Halogen GLS T3 100°C 10 mins
621 75 W Halogen GLS T4 33°C 10 mins