Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Iecex Sir 06.0043X

Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

IECEx Certificate

of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION
IEC Certification Scheme for Explosive Atmospheres
for rules and details of the IECEx Scheme visit www.iecex.com

Certificate No.: IECEx SIR 06.0043X Issue No: 7 Certificate history:


Issue No. 7 (2011-12-14)
Status: Current Page 1 of 4 Issue No. 6 (2011-02-08)
Issue No. 5 (2009-11-25)
Date of Issue: 2011-12-14 Issue No. 4 (2008-12-01)
Issue No. 3 (2007-08-30)
Applicant: CMP Products Limited Issue No. 2 (2007-06-25)
Glasshouse Street Issue No. 1 (2007-01-23)
St Peters, Newcastle-upon-Tyne
Tyne and Wear NE6 1BS
United Kingdom

Electrical Apparatus: E** Type Range of Cable Glands


Optional accessory:

Type of Protection: Flameproof, Increased Safety and Dust

Marking: Ex d IIC/Ex e II /Ex nR II or Ex d I/Ex e I or


Ex d IIC or Ex d I or
Ex e II or Ex e I or
Ex nR II
Ex tD A21 IP66

Approved for issue on behalf of the IECEx C Ellaby


Certification Body:

Position: Deputy Certification Manager

Signature:
(for printed version)

Date:

1. This certificate and schedule may only be reproduced in full.


2. This certificate is not transferable and remains the property of the issuing body.
3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website.

Certificate issued by:


SIRA Certification Service
Rake Lane
Eccleston
Chester
CH4 9JN
United Kingdom
IECEx Certificate
of Conformity
Certificate No: IECEx SIR 06.0043X Issue No: 7

Date of Issue: 2011-12-14 Page 2 of 4

Manufacturer: CMP Products Limited


Glasshouse Street
St Peters, Newcastle-upon-Tyne
Tyne and Wear NE6 1BS
United Kingdom

Additional Manufacturing
location(s):

This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the
IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and
found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx
Scheme Rules, IECEx 02 and Operational Documents as amended.

STANDARDS:
The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was
found to comply with the following standards:

IEC 60079-0 : 2004 Electrical apparatus for explosive gas atmospheres - Part 0: General requirements
Edition:4.0
IEC 60079-1 : 2007-04 Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d"
Edition:6
IEC 60079-15 : 2005-03 Electrical apparatus for explosive gas atmospheres Part 15: Construction, test and Marking of Type of
Edition:3 Protection "n" electrical apparatus
IEC 60079-7 : 2006-07 Explosive atmospheres - Part 7: Equipment protection by increased safety "e"
Edition:4
IEC 61241-0 : 2004 Electrical apparatus for use in the presence of combustible dust - Part 0: General requirements
Edition:1
IEC 61241-1 : 2004 Electrical apparatus for use in the presence of combustible dust - Part 1: Protection by enclosures "tD"
Edition:1

This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the

Standards listed above.

TEST & ASSESSMENT REPORTS:


A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in

Test Report:

GB/SIR/ExTR06.0061/00 GB/SIR/ExTR07.0002/00 GB/SIR/ExTR07.0042/00


GB/SIR/ExTR08.0126/00 GB/SIR/ExTR09.0185/00 GB/SIR/ExTR10.0317/00
GB/SIR/ExTR11.0305/00

Quality Assessment Report:

GB/SIR/QAR06.0011/00 GB/SIR/QAR07.0009/02
IECEx Certificate
of Conformity
Certificate No: IECEx SIR 06.0043X Issue No: 7

Date of Issue: 2011-12-14 Page 3 of 4

Schedule

EQUIPMENT:
Equipment and systems covered by this certificate are as follows:

The E** series Type ranges of cable glands consist of a male-threaded front entry component containing an elastomeric
sealing ring and a Nylon 6 skid washer which effect flameproof sealing onto the cable inner sheath and is intended to
screw into an entry point of its associated enclosure in accordance with relevant codes of practice. The flameproof seal is
actuated by an adjoining coupling component. The coupling component is attached to a main body. Their mating thread
may be fitted with an optional ‘O’ ring seal to provide increased ingress protection. Clamping of the armoured or braided
cable is effected by a combination of the coupling component, main body and the different optional armour cone and
armour sleeve combinations being fastened together. An outer seal nut, containing an elastomeric sealing ring and a Nylon
6 ferrule, threads onto the main body and effects environmental sealing onto the cable outer sheath. Cable clamping is
achieved with the outer seal arrangement.

Refer to Annex for more details.

CONDITIONS OF CERTIFICATION: YES as shown below:

The E** type cable glands shall only be used where the temperature, at the point of entry, is between -60°C to
1. +130°C.
2. The E** type cable glands terminated on braided cables are not suitable for group I applications.
3. The E** type cable glands are fitted with one specific size of FLP sealing ring per gland size as supplied
4. The E** type cable glands used for terminating braided cables are only suitable for fixed installations. Cables must
be effectively clamped to prevent pulling or twisting.
5. The E** type of cable gland entry component threads may need additional sealing to maintain the ingress
protection rating as applicable to the associated equipment in which it will be attached.
6. When assembled for fitting to flexible conduit, the conduit shall be effectively clamped to prevent twisting and
pulling
IECEx Certificate
of Conformity
Certificate No: IECEx SIR 06.0043X Issue No: 7

Date of Issue: 2011-12-14 Page 4 of 4

DETAILS OF CERTIFICATE CHANGES (for issues 1 and above):

Issue 1 – this Issue introduced the following change:


1 The introduction of an alternative, outer sealing arrangement; the compression
nut length and consequently body length are reduced, in addition, the internal,
tapered ferrule is replaced by a flat ferrule.
Issue 2 – this Issue introduced the following changes:
1 The introduction of Ex nR II and Ex tD coding.
2 The recognition of alternative armour cone diameters.
3 The removal of the manufacturer's address from the product marking.
4 The use of the E** Cable glands with pliable wire armour cables.
Issue 3 – this Issue introduced the following change:
1 Correction of description in Annex to include 25/32 size in table. Omitted in
error.
Issue 4 - this Issue introduced the following changes:
1 The addition of the 20s16/20s and 20/25s sizes.
2 The use of alternative armour cones machined for varying armour wire
diameters.
3 The inclusion of steel wire armour cable (s.w.a) in the cone/clamping
description.
4 The Inclusion of ‘size-up’ entry threads.
Issue 5 – this Issue introduced the following changes:
1 The recognition of an alternative outer seal arrangement to allow the fitting of
the E** glands to flexible conduit , including a new Special Condition For Safe
use.
2 The addition of the size 16 gland to the E**, range.
Issue 6 – this Issue introduced the following change:
1 Following appropriate re-assessment to demonstrate compliance, the originally
listed standards IEC 60079-1:2003 and IEC 60079-7:2001 were replaced by
IEC 60079-1:2007 and IEC 60079-7:2006 respectively.
Issue 7 – this Issue introduced the following change:
1 The Condition of Certification that imposed tightening restriction to the E**-Type
Ranges to achieve IP 66 was proven to be unnecessary and was removed.

Annex:

IECEx SIR 06.0043X Iss_7 Annex.pdf


Annexe to: IECEx SIR 06.0043X Issue 7

Applicant: CMP Products Ltd

Apparatus: E** Type Range of Cable Glands


CERTIFICATION
Description (continued):
Design options
• The front entry component may be manufactured with a profiled groove to captivate an ‘O’ ring seal which locates
on the mating face with the associated enclosure. This option having the gland type designation prefixed with the
letter R, e.g. 25RE**.
• Alternative materials of manufacture:
Brass to BS2874:1986 Grade CuZn39Pb (CW614N)
Mild steel to BS970 Pt1:1991 Grade 220M07Pb
Stainless steel to BS970 Pt1:1991 Grades 316S11, 316S13, 316S31 or 316S33
Aluminium alloy to BS1474:1987 Grade 6082 or BS1490 Grade LM25 TF (Not Group I)
• Alternative entry component thread forms:
Metric ISO 965-1, ISO965-3 medium fit (6g) for external threads
ET(Conduit) BS 31:1940 (1979), Table A
PG DIN 40430:1971
BSPP BS 2779:1973 class A full form for external threads
BSP TBS 21:1985 standard threads only as clause 5.4, gauging to clause 5.2 system A
ISO ISO 7/1:1982, gauging to ISO 7/2 clause 6.3 for external threads
NPT ANSI/ASME B1.20.1-1983 gauging to clause 8.1 for external threads
NPSM ANSI/ASME B1.20.1-1983 gauging to clause 9 for external threads
• The use of alternative armour clamping components. The various arrangements vary the cable gland suitability for
differing armour or braided type cables.
• The use of a component having an alternative profile allowing an integral earthing facility. The type designation
identifying the cable gland being fitted with this option.
• The use of metallic continuity diaphragm component specified by the cable gland type designation for use when
terminating lead sheathed cables.
• Alternative material of manufacture of the ferrule or skid washer to be the same as the gland material.
• Glands may be fitted with armour cones with alternative diameters to allow the clamping of smaller or larger
armour wires.
• Alternative outer seal arrangement to allow the fitting of the E** glands to flexible conduit , including a new Special
Condition For Safe use
The gland and seal sizes are determined by the entry thread and cable range take sizes:
Gland size Entry Entry thread Inner seal sheath SWA SWA, STA, strip armour, Outer seal sheath
thread ‘B’ version range Ø (mm) (mm) pliable wire armour* & range Ø (mm)
wire braid (mm)
Min. Max. Min. Max. Min. Max. Min. Max
16 M16 x 1.5 - 3.1 8.6 0.9 1.00 0 1.0 6.1 11.5
20s/16 M20 x 1.5 M25 x 1.5 3.1 8.6 0.9 1.00 0 1.0 6.1 11.5
20s16/20s M20 x 1.5 M25 x 1.5 3.1 8.6 0.9 1.25 0 1.0 9.5 15.9
20s M20 x 1.5 M25 x 1.5 6.1 11.6 0.9 1.25 0 1.0 9.5 15.9
20s/20 M20 x 1.5 M25 x 1.5 6.1 11.6 0.9 1.25 0 1.0 12.5 20.9
20 M20 x 1.5 M25 x 1.5 6.5 13.9 0.9 1.25 0 1.0 12.5 20.9
20/25S M20 x 1.5 M25 x 1.5 6.5 13.9 1.25 1.6 0 1.0 14.0 22.0
20/25 M20 x 1.5 M25 x 1.5 6.5 13.9 1.25 1.6 0 1.0 18.2 26.2
25s M25 x 1.5 M32 x 1.5 11.1 19.9 1.25 1.6 0 1.0 14.0 22.0
25 M25 x 1.5 M32 x 1.5 11.1 19.9 1.25 1.6 0 1.0 18.2 26.2
25/32 M25 x 1.5 M32 x 1.5 11.1 19.9 1.6 2.0 0 1.0 23.7 33.9
32 M32 x 1.5 M40 x 1.5 17.0 26.2 1.6 2.0 0 1.0 23.7 33.9
32/40 M32 x 1.5 M40 x 1.5 17.0 26.2 1.6 2.0 0 1.0 27.9 40.4
40 M40 x 1.5 M50 x 1.5 22.0 32.1 1.6 2.0 0 1.0 27.9 40.4
40/50s M40 x 1.5 M50 x 1.5 22.0 32.1 2.0 2.5 0 1.0 35.2 46.7
50s M50 x 1.5 M63 x 1.5 29.5 38.1 2.0 2.5 0 1.0 35.2 46.7
50s/50 M50 x 1.5 M63 x 1.5 29.5 38.1 2.0 2.5 0 1.0 40.4 53.1
50 M50 x 1.5 M63 x 1.5 35.6 44.0 2.0 2.5 0 1.0 40.4 53.1
50/63s M50 x 1.5 M63 x 1.5 35.6 44.0 2.0 2.5 0 1.0 45.6 59.4
63s M63 x 1.5 M75 x 1.5 40.1 49.9 2.0 2.5 0 1.0 45.6 59.4
63s/63 M63 x 1.5 M75 x 1.5 40.1 49.9 2.0 2.5 0 1.0 54.6 65.9
63 M63 x 1.5 M75 x 1.5 47.2 55.9 2.0 2.5 0 1.0 54.6 65.9
63/75s M63 x 1.5 M75 x 1.5 47.2 55.9 2.0 2.5 0 1.0 59.0 72.1
75s M75 x 1.5 M90 x 2.0 52.8 61.9 2.0 2.5 0 1.0 59.0 72.1
75s/75 M75 x 1.5 M90 x 2.0 52.8 61.9 2.5 3.0 0 1.0 66.7 78.5

Sira Certification Service


Date: 14 December 2011 Page 1 of 2 Rake Lane, Eccleston, Chester, CH4 9JN, England
Tel: +44 (0) 1244 670900
Fax: +44 (0) 1244 681330
Form 9530 Issue 1
Email: info@siracertification.com
Web: www.siracertification.com
Annexe to: IECEx SIR 06.0043X Issue 7

Applicant: CMP Products Ltd

Apparatus: E** Type Range of Cable Glands


CERTIFICATION
Gland size Entry Entry thread Inner seal sheath SWA SWA, STA, strip armour, Outer seal sheath
thread ‘B’ version range Ø (mm) (mm) pliable wire armour* & range Ø (mm)
wire braid (mm)
Min. Max. Min. Max. Min. Max. Min. Max
75 M75 x 1.5 M90 x 2.0 59.1 67.9 2.5 3.0 0 1.0 66.7 78.5
75/90 M75 x 1.5 M90 x 2.0 59.1 67.9 3.0 3. 5 0 1.6 76.2 90.4
90 M90 x 2.0 M100 x 2.0 66.6 79.9 3.0 3. 5 0 1.6 76.2 90.4
90/100 M90 x 2.0 M100 x 2.0 66.6 79.9 3.15 4.0 0 1.6 86.1 101.5
100 M100 x 2.0 M115 x 2.0 76.0 90.9 3.15 4.0 0 1.6 86.1 101.5
100/115 M100 x 2.0 M115 x 2.0 76.0 90.9 3.15 4.0 0 1.6 101.5 110.3
115 M115 x 2.0 M130 x 2.0 86.0 97.9 3.15 4.0 0 1.6 101.5 110.3
115/130 M115 x 2.0 M130 x 2.0 86.0 97.9 3.15 4.0 0 1.6 114.2 123.3
130 M130 x 2.0 N/A 97.0 114.9 3.15 4.0 0 1.6 114.2 123.3
* - ‘X’ and ‘U’ variants; see below
Type designation code
E F /

C = Fitted with the alternative cast integral earth lug entry component.
W = Fitted with single plain armour cone & reversible armour sleeve to suit SWA cables.
X = Fitted with single grooved armour cone & reversible armour sleeve to suit STA, strip armoured,
pliable wire armoured and braided cables
U = Fitted with reversible armour cone & reversible armour sleeve to suit SWA, STA, strip
armoured, pliable wire armoured and braided cables.
1 = Standard circular armoured and braided cables.
2 = Inner seal fitted with additional metallic continuity diaphragm for the use with inner lead sheathed SWA,
strip armoured and braided cables.

Sira Certification Service


Date: 14 December 2011 Page 2 of 2 Rake Lane, Eccleston, Chester, CH4 9JN, England
Tel: +44 (0) 1244 670900
Fax: +44 (0) 1244 681330
Form 9530 Issue 1
Email: info@siracertification.com
Web: www.siracertification.com

You might also like