Gas Pressure Regulators

Control Valves

Safety Devices

Valves and Actuators

Gas Treatment

Gas Metering

Smart Gas Grid

Stations

Services

3
Gas Pressure Regulators

Pilot Operated Pressure Regulators

Reflux 819
Pilot-operated “fail close” regulator

Design pressure: up to 102 bar (1479 Psig)


Inlet pressure range: 0,8 to 102 bar ( 11,6 to 1479 Psig)
Outlet pressure range: 0,3 to 74 bar (5 to 1073 Psig)
Design temperature range: -20°C to + 60°C (-4° to + 140°F)
Ambient temperature range: -40°C to + 60°C (-40° to + 140°F)
Accuracy class AC: up to 1
Lock-up pressure class SG: up to 5
Available sizes DN: 1” -2” -3” -4” -6” -8” -10” Reflux 819 ...+SB82
Flanging: class 150-300-600 RF or RTJ and PN16

Modular Accessories:
- Incorporated slam shut valve (SB/82 or HB/97).
- Incorporated silencer (DB/819).
- In line monitor function (PM/819).

...+PM819 + DB819

Reflux 819/FO
Pilot-operated “fail open” regulator
Design pressure: up to 102 bar (1479 Psig)
Inlet pressure range: 3 to 102 bar ( 43 to 1479 Psig)
Outlet pressure range: 1 to 74 bar (14,5 to 1073 Psig)
Design temperature range: -20°C to + 60°C (-4° to + 140°F)
Ambient temperature range: -40°C to + 60°C (-40° to + 140°F)
Accuracy class AC: up to 1
Lock-up pressure class SG: up to 5
Available sizes DN: 1” -2” -3” -4” -6” -8” -10” ...+SB82 Reflux/FO
Flanging: class 150-300-600 RF or RTJ and PN16

Modular Accessories:
- Incorporated slam shut valve (SB/82 or HB/97).
- Incorporated silencer (DB/819).
- In line monitor function (PM/819).

...+DB819

The following symbols indicate the application area suggested for each product.
Providing Solutions for Oil and Gas

Aperflux 851 / 101


Pilot-operated “fail open” regulator

Design pressure: up to 102 bar (1479 Psig)


Inlet pressure range: 1,3 to 85 bar (18,8 to 1230 Psig)
Outlet pressure range: 0,8 to 74 bar (12 to 1073 Psig)
Design temperature range: -20°C to + 60°C (-4° to + 140°F)
Ambient temperature range: -40°C to + 60°C (-40° to + 140°F)
Accuracy class AC: up to 1
Lock-up pressure class SG: up to 5
...+SB82 + DB851 Aperflux 851
Available sizes DN: 1” -2” -3” -4” -6” -8” -10”
Flanging: class 150-300-600 RF or RTJ and PN16

Modular Accessories:
- Incorporated slam shut valve (SB/82 or HB/97).
- Incorporated silencer (DB/851).
- In line monitor function (PM/819).

... +PM819 Aperflux 101

Dixi/AP
Pilot-operated “fail close” regulator
Design pressure: up to 85 bar (1232 Psig)
Inlet pressure range: 1,5 to 85 bar (21,75 to 841 Psig)
Outlet pressure range: 0,5 to 25 bar (7,25 to 362 Psig)
Design temperature range: -20 °C to +60 °C (-4 to + 140°F)
Ambient temperature range: -40°C to + 60°C (-40° to + 140°F)
Accuracy class: AC: up to 1
Lock-up pressure class SG: up to 5
Dixi/AP ...+SB Available size DN: 1”
Flanging: class 300-600 RF or RTJ and PN 16-25-40

Modular Accessories:
- Incorporated slam shut valve (SB/87).

Exploration Distribution Residential and


& Production Transmission & Industrial Commercial 5
For more information please visit our website at: www.fiorentini.com
Gas Pressure Regulators

Pilot Operated Pressure Regulators

DIXI
Pilot-operated "fail close" regulator

Design pressure: up to 18,9 bar (275 Psig)


Inlet pressure range: 0.5 to 18,9 bar (7,25 to 275 Psig)
Outlet pressure range: 6 to 6000 mbar (2,4" w.c. to 87 Psig)
Design temperature range: -20 °C + 60 °C (-4° to + 140 °F)
Ambient temperature range: -40 °C to +60 °C (-40° to + 140 °F)
Accuracy class AC: up to 2,5
Lock-up pressure class SG: 10
Available sizes DN: 1” - 1”1/2 - 1”1/4 Dixi
Flanging: class 150 RF and PN16

Modular Accessories:
- Incorporated slam shut valve (LA).

Reval 182
Pilot-operated “fail close” regulator

Design pressure: up to 25 bar (362,5 Psig)


Inlet pressure range: 0,15 to 25 bar ( 2,2 to 362,5 Psig)
Outlet pressure range: 7 mbar to 12 bar (2,8”w.c. to 174 Psig)
Design temperature range: -20°C to + 60°C (-4° to + 140°F)
Ambient temperature range: -40°C to + 60°C (-40° to + 140°F)
Accuracy class AC: up to 2,5
Lock-up pressure class SG: 10
Reval 182 ... + SB82
Available sizes DN: 1” -2” -2”1/2 -3” -4” -6” -8” -10”
Flanging: class 150 RF or RTJ and PN16/25/40

Modular Accessories:
- Incorporated slam shut valve (SB/82 or SA type).
- Incorporated silencer (DB/182).
- In line monitor function (PM/819).

... +PM819 ...+ DB/182 + SB82

The following symbols indicate the application area suggested for each product.
Providing Solutions for Oil and Gas

Terval
Pilot-operated regulator with three in one functions:
main regulator, monitor, slam-shut
TERVAL/A “fail open” main regulator Aperval + Reval monitor "fail close"
TERVAL/R “fail close” main regulator Reval + Reval monitor "fail close"

Design pressure: up to 25 bar (362 Psig)


Inlet pressure range: 0,5 to 25 bar ( 7.25 to 362 Psig)
Outlet pressure range: 5 mbar to 9500 mbar (2”w.c. to 137.5 Psig)
...+DB Terval
Design temperature range: -20°C to + 60°C (+4° to + 140°F)
Ambient temperature range: -40 °C to +60 °C (-40° to + 140°F)
Accuracy class AC: up to 2,5
Lock-up pressure class SG:up to 5
Available sizes DN: 2” -2”1/2 -3” -4”
Flanging: class 150 RFand PN16

Modular Accessories:
- Incorporated silencer (DB)
Terval/R

Aperval
Pilot-operated “fail open” regulator

Design pressure: up to 25 bar (362 Psig)


Inlet pressure range: 0,5 to 25 bar ( 7.25 to 362 Psig)
Outlet pressure range: 5 mbar to 9500 mbar (2”w.c. to 137.5 Psig)
Design temperature range: -20°C to + 60°C (-4° to + 140 °F)
Ambient temperature range: -40 °C to +60 °C (-40° to + 140°F)
Accuracy class AC: up to 2,5
Lock-up pressure class SG: up to 5
Aperval 101 Aperval Available sizes DN: 1” -2” -2”1/2 -3” -4”
Flanging: class 150 RF or RTJ and PN25/40

Modular Accessories:
- Incorporated slam shut valve (SA).
- Incorporated silencer (DB/182).
- In line monitor function (PM/182).

Exploration Distribution Residential and


& Production Transmission & Industrial Commercial 7
For more information please visit our website at: www.fiorentini.com
Gas Pressure Regulators

Direct Acting Pressure Regulators

Norval
Spring loaded regulator

Design pressure: up to 18,9 bar (275 Psig)


Outlet pressure range: 8 to 4400 mbar (3”w.c. to 63,8 Psig)
Design temperature range: -20 °C to +60 °C (-4° to + 140 °F)
Ambient temperature range: -40 °C to +60 °C (-40° to + 140 °F)
Accuracy class AC: up to 5
Lock-up pressure class SG: up to 10
Available sizes DN: 1” - 1”1/2 - 2” - 2”1/2 - 3” - 4”- 6”- 8”
Flanging: class 150 RF and PN16 Norval ...+SN

Modular Accessories:
- Incorporated slam-shut valve (SN).
- in-line monitor function.

Dival 160/AP
Spring loaded regulator

Design pressure: up to 85 bar (1232 Psig)


Outlet pressure range: 0,85 to 4,5 bar (12,32 to 62,85 Psig)
Design temperature range: -10 °C + 60 °C (14° to + 140 °F)
Ambient temperature range: -20 °C to +60 °C (-4° to + 140 °F)
Accuracy class AC: up to 10
Lock-up pressure class SG: up to 10
Available sizes DN: 1"
Flanges: class 300-600 RF Dival 160/AP

Modular Accessories:
Incorporated slam-shut valve (SB/87).

The following symbols indicate the application area suggested for each product.
Providing Solutions for Oil and Gas

Trias
Multifunction spring loaded regulator

TRIAS/BB - Main regulator + 2 slam-shut valves


Inlet pressure range: 0,2 - up to 17 bar (2,9 to 246 Psig)
Outlet pressure range: 15 to 4000 mbar (6,02" w.c. to 58 Psig)
Design temperature range: -20 °C to +60 °C (-4° to + 140 °F)
Ambient temperature: -40 °C to +60 °C (-40° to + 140 °F)
Accuracy class AC: up to 5
Lock-up pressure class SG: up to 10
Trias/BB Trias/BM
TRIAS/M: Main regulator + monitor
TRIAS/BM: Main regulator + monitor + slam-shut valve
Inlet pressure range: 0,2 - up to 8 bar (2,9 to 116 Psig)
Outlet pressure range:15 to 4000 mbar (6,02" w.c. to 58 Psig)
Design temperature range: -20 °C to +60 °C (-4° to + 140 °F)
Ambient temperature: -40 °C to +60 °C (-40° to + 140 °F)
Accuracy class AC: up to 5
Lock-up pressure class SG: up to 10

Trias/M Available sizes DN: 1" 1/2 - 2”


Flanging class: ANSI 150 RF; PN 16

Staflux 185
Direct-acting regulator with pressurized chamber

Design pressure: up to 102 bar (1479 Psig)


Inlet pressure range: 1,3 to 85 bar (18,85 to 1233 Psig)
Outlet pressure range:1 to 75 bar (14,5 to 1087 Psig)
Design temperature range: -20 °C to + 60 °C (-4 to + 140 °F)
Ambient temperature range: -40 °C to + 60°C (-40° to + 140 °F)
Accuracy class AC: up to 5
Lock-up pressure class SG: up to 10
Staflux 185 Available sizes DN: 1” - 2” - 3”
Flanging: class ANSI 300-600 RF or RTJ

Modular Accessories:
Incorporated slam-shut valve (SB/185).

Staflux 187
Direct-acting regulator with pressurized chamber

Design pressure: up to 250 bar (3626 Psig)


Inlet pressure range: 2 to 250 bar (29 to 3626 Psig)
Outlet pressure range: 1 to 75 bar (14,5 to 1087 Psig)
Design temperature range: -20 °C to + 60 °C (-4° to + 140 °F)
Ambient temperature range: -30 °C to + 60 °C (-22° to + 140 °F)
Accuracy class AC: up to 5
Lock-up pressure class SG: up to 10
Staflux 187 Available size1 DN: 1”
Flanging: class ANSI 1500 RF

Exploration Distribution Residential and


& Production Transmission & Industrial Commercial 9
For more information please visit our website at: www.fiorentini.com
Gas Pressure Regulators

Direct Acting Pressure Regulators

ATF Anti-freeze
One-stage pressure reducing valve

Design pressure: 250 bar (3626 Psig)


Inlet pressure range: 2 to 250 bar (29 to 3626 Psig)
Outlet pressure range: 1,5 to 60 bar (21,75 to 870 Psig)
Design and ambient temperature range: -20 °C to +60 °C (-4° to + 140 °F)
Accuracy class: up to 5
Lock-up pressure class SG: up to 10
Threaded connections: Piping connection: Dn 1” ANSI B 2.1 NPT
ATF 15 Anti-freeze
Outlet connection: Rp 1/4” IS0 7/1.
ATF 16: Heating fluid side connection: 2” NPT · Inlet gas side connection:
1/4"" NPT · Outlet gas side connection: Rp 1/4” IS07/1."

Dival 600
Spring loaded regulator

Inlet pressure range: 0,1 to 20 bar (40" w.c. - 290 Psig)


Outlet pressure range: 12 to 4200 mbar (5" - 1688" w.c.)
Design temperature range: -20 °C to +60 °C (-4° to + 140 °F)
Ambient temperature range: -40 °C to +60 °C (-40° to + 140 °F)
Accuracy class AC: up to 5
Lock-up pressure class SG: up to 10
Available sizes: DN 1” (25) - 1”1/2 (40) - 2” (50)
Dival 600 ... + LA
Flanging class: PN 16/25; ANSI 150 RF , ANSI 125 FF
Threaded connections: DN 2" Rp ISO 7/1 orDN 2" NPTF

Modular Accessories:
- Incorporated slam shut valve for over and under pressure (LA).
- In line monitor function.
- Incorporated silencer.
- Relief valve.

Dival 700
Burner regulator

Inlet pressure range: 0,1 to 8,63 bar (40" w.c. - 125 Psig)
Outlet pressure range: 5 to 1454 mbar (2" - 21 Psig)
Design temperature range: -20 °C to +60 °C (-4° to + 140 °F)
Ambient temperature range: -40 °C to +60 °C (-40° to + 140 °F)
Accuracy class AC: up to 5
Lock-up pressure class SG: up to 5
Available sizes: DN 1” (25) - 1”1/2 (40) - 2” (50)
Dival 700 ... + LA
Flanging class: PN 16/25; ANSI 150 RF , ANSI 125 FF
Threaded connections: DN 2" Rp ISO 7/1 orDN 2" NPTF

Modular Accessories:
- Incorporated slam shut valve for over and under pressure (LA).
- In line monitor function.
- Relief valve.

The following symbols indicate the application area suggested for each product.
Providing Solutions for Oil and Gas

Dival 500
Spring loaded regulator

Inlet pressure range: BP 0,5 up to 10 bar (7,3 - 145 Psig)


MP-TR: 0,5 up to 20 bar (7,3 - 290 Psig)
Outlet pressure range: 15 to 2500 mbar (6" – 1004" w.c.)
Design temperature range: -20 °C to + 60 °C (-4° to + 140 °F)
Ambient temperature range: -40 °C to + 60 °C (-40° to + 140 °F)
Available sizes:1”x1” ISO 7/1; 1”x1”1/2 ISO 7/1 (NPT on demand)
Screwed or flanged PN16 & ANSI 150
Dival 500 LA Type
Modular Accessories:
- Incorporated slam shut valve for over and under pressure (LA).
- In line monitor function.
- Incorporated relief valve

Dival 507 - 512


Spring loaded regulator

Inlet pressure range: BP: 0.5÷10 bar (7,3 – 145 Psig)


MP –TR: 0,5 – 20 bar (7,3 – 290 Psig)
Outlet pressure range: 15 mbar to 3000 mbar (6" – 1205" w.c.)
Design temperature range: -20 °C to + 60 °C (-4° to + 140 °F)
Ambient temperature range: -40 °C to + 60 °C (-40° to + 140 °F)
Available sizes: Dival 507 1” x 1" ISO 7/1
Dival 507 - 512 Dival 512 1” x 1"1/2 ISO 7/1
Dival 507 - 512
Screwed or flanged PN 16 & ANSI 150

Modular Accessories:
- Incorporated slam shut valve for over and under pressure (LA).
- In line monitor function.
- Incorporated relief valve

Exploration Distribution Residential and


& Production Transmission & Industrial Commercial 11
For more information please visit our website at: www.fiorentini.com
Gas Pressure Regulators

Residential Gas Pressure Regulators

Governors
Pressure regulator, with or without integral filter

Inlet pressure range: 2,5 mbar to 500 mbar (1" to 200" w.c.)
Max allowable pressure PS: 1 Bar (14,5 Psig)
Outlet pressure range: 5 to 300 mbar (2" to120" w.c.)
Accuracy class AC: up to 15 (EN 88-2)
Lock-up pressure class SG: +7.5 mbar (3 w.c.) / up to +30% of the Pd (EN 88-2)
Design and Ambient temperature range: -15°C + 60°C (5° to 140°F)

Governors

GR6
Double stage low pressure regulators

Inlet pressure range: 150-400 mbar (60,3" - 160,7" w.c.)


Max allowable pressure PS: 5bar (72,5 Psig)
Max outlet pressure: 20 mbar (8" w.c.)
Max outlet pressure during reset: 50 mbar
Accuracy class AC: 10
Lock up pressure class SG: 25
Design temperature range: - 5°+ 40° C (+25° +104°F)
Ambient temperature range: - 25° + 60° C (-13° +140° F) GR6

FE - FB
Double Stage Pressure Regulators

FE-FB 6-10-25-50 stmc/h N.G.


Inlet pressure range: 0,15-7 bar (60"w.c. - 102 Psig)
Max allowable pressure PS: 8.6 Bar (125 Psig)
Outlet pressure range: 13 to 500 mbar (5.2" ÷ 201” w.c.)
Accuracy class AC: up to 5
Lock up pressure class SG: up to 20
Design temperature range - 25° + 60° C ( -13° +140° F)
Ambient temperature range: - 40° to + 60° C (- 40° +140° F)
FE FB

Modular Accessories:
- Safety shut-off device for over and under pressure.
- Relief valve.
- Inlet filter.
- Excess flow valve

The following symbols indicate the application area suggested for each product.
Providing Solutions for Oil and Gas

FEX
Double Stage Pressure Regulators

FEX 50-75-100 stmc/h N.G.


Inlet pressure range: 0,3 -8,6 bar (120"w.c. - 125 Psig)
Max allowable pressure PS: 8.6 Bar (125 Psig)
Outlet pressure range: 13 - 350 mbar (5.2" - 140,6" w.c.)
Accuracy class AC: up to 5
Lock up pressure class SG: up to 20
Design temperature range - 25° + 60° C ( -13° +140° F)
FEX Ambient temperature range -40° to + 60° C (-40° to + 140° F)

Modular Accessories:
- Safety shut-off device for over and under pressure.
- Relief valve.
- Inlet filter.

B6-B10
Natural Gas pressure regulator

Inlet connection: Nut 3/4'' Spherical Cone Joint


Outlet connection:B6: Nut 6/20 Flat Gas Meter Joint
B10: Nut 10/32 Flat Gas Meter Joint
Design temperature range -20° to + 60° - (-4° +140°F)
Flow B6: 6 m3/h to 300 mbar (120" w.c.) -7.2 m3/h guarantee at 500 mbar (200 "w.c.)
B10 10 m3/h to 300 mbar (120" w.c.) -12 m3/h guarantee at 500 mbar (200" w.c.)
Set security flow B6-B10: Between 110 and 150% of nominal flow
B6-B10 B6 UNN - B10 UN Between 120 and 150% of nominal flow
Standard: Authorized by GDF

HP 100
Single stage high pressure spring loaded regulator

Inlet pressure range: 1÷20 bar (14.5÷290 Psig)


Max allowable pressure PS: 20 bar (290 Psig)
Outlet pressure range:
AP: 200÷800 mbar ( 80,4" - 321.5" w.c.)
TR: 800÷4500 mbar (321.5"- 1808.4" w.c.)
Accuracy class: AC up to 5
Lock up pressure class SG: up to 30
HP 100/B HP100 Design and temperature range: -20°C +60°C - (-4° +140°F)

Modular Accessories:
- Safety shut-off device for lack of feeding.
- In Line monitor function.
- Relief valve.
- Inlet filter.

HP 100 + Monitor

Exploration Distribution Residential and


& Production Transmission & Industrial Commercial 13
For more information please visit our website at: www.fiorentini.com
Control Valves

Control Gas Valves

Reflux 919
Pneumatic control valve

Design pressure PS: up to 102 bar (1479 Psig)


Maximum inlet pressure: 85 bar (1232 Psig)
Maximum pressure drop: 83 bar (1203 Psig)
Rangeability: 500:1
Direct or reverse action
Design temperature range - 20° + 60° C ( - 4° +140° F)
Ambient temperature range - 40° to + 60° C (- 40° to +140° F)
Available sizes DN: 1"-2"-3"-4"-6"-8"-10" Reflux 919
Flanges: ANSI 150/300/600 RF or RTJ

Modular Accessories:
- Incorporated slam shut valve (SB/82 or HB/87).
- Incorporated silencer (DB/919).
- Pneumatic or electropneumatic positioner.
- Excess flow valve

VLM
Manual actuated control valve

Design pressure PS: up to 102 bar (1479 Psig)


Maximum pressure drop: 83 bar (1203 Psig)
Rangeability: 200:1
Design temperature range: - 20° + 60° C ( - 4° +140° F)
Ambient temperature range: - 40° to + 60° C ( - 40° to +140° F)
Available sizes DN: 1”- 2”- 3”- 4”- 6”- 8”- 10”
Flanging: ANSI 150/300/600 RF - RTJ; PN 16 /25/40
VLM
Modular Accessories:
- Incorporated slam shut valve (SB/82).

The following symbols indicate the application area suggested for each product.
Providing Solutions for Oil and Gas

Syncroflux
Electrically actuated control valve

Design pressure PS: up to 102 bar (1479 Psig)


Maximum pressure drop 83 bar (1203 Psig)
Rangeability: 500:1
Design temperature range - 20° + 60° C ( - 4° +140° F)
Ambient temperature range - 40° to + 60° C (- 40° to +140° F)
Size DN: 1”- 2”- 3”- 4”- 6”- 8”- 10”
Flanging: ANSI 150/300/600 RF-RTJ; PN16
Syncroflux
Modular Accessories:
- Incorporated slam shut valve (SB/82 or HB/97).
- Incorporated silencer (DB/819).

Deltaflux
Pneumatic, electric or manually operated
control valve
Design pressure PS: up to 220 bar (3190,83 Psig)
Design temperature range: -29°C to + 121°C (-20 to + 250 °F)
Rangeability: 200:1
Sizes DN: up to 24”
Flanges: ANSI 150/300/600/900/1500 according to ASME B 16.34
Deltaflux End to end dimension: according to API 6D
Options: gas flow control application, liquid flow control
application.

Exploration Distribution Residential and


& Production Transmission & Industrial Commercial 15
For more information please visit our website at: www.fiorentini.com
Safety Devices

Slam Shut Valves

HBC 975
Slam-shut valve

Design pressure PS: 102 bar (1479 Psig)


Design temperature range: - 20 °C to +60 °C (-4° to + 140 °F)
Ambient temperature range: - 40° to + 60° C (- 40° to + 140° F)
Over-pressure range: 1,3 to 85 bar (18,85 to 1232 Psig)
Under-pressure range: 0,4 to 75 bar (5,8 to 1087 Psig)
Accuracy class AG: up to 1
Available sizes DN: 4”- 6”- 8”- 10”
Flanges: ANSI 300/600 RF-RTJ; HBC 975

SBC/782
Slam-shut valve

Design pressure PS: up to 102 bar (1479 Psig)


Design temperature range: -20 °C to +60 °C (-4° to + 140 °F)
Ambient temperature range: - 40° to + 60° C (- 40° to + 140° F)
Over-pressure range: 0,02 to 100 bar (8”w.c. to 1450 Psig )
Under-pressure range: 0,01 to 88 bar(4”w.c. to 1276 Psig)
Accuracy class AG: up to 1
Available sizes DN: 1” - 2” - 2”1/2 - 3” - 4”- 6” - 8” -10”
Flanges: ANSI 150 - 300 -600 RF and PN 16/25/40 SBC/782

SCN
Slam-shut valve

Design pressure PS: 18,9 bar (274,5 Psig)


Design temperature range: - 20 °C to +60 °C (-4° to + 140 °F)
Ambient temperature range: - 40° to + 60° C (- 40° to + 140° F)
Over-pressure range: 0,025 to 5 bar ( 10”w.c. to 72,5 Psig )
Under-pressure range: 0,01 to 3 bar ( 4”w.c. to 43,5 Psig )
Accuracy class AG: ±5% to 10% for over pressure,
10% to 20% for under pressure
Available sizes DN: 1” - 1”1/2 - 2” - 2”1/2 - 3” - 4”- 6” - 8” SCN
Flanges: ANSI 150 RF or FF and PN 16

Dilock
Slam-shut valve

Design pressure PS: up to 18,9 bar (275 Psig)


Design temperature range: - 20 °C to +60 °C (-4° to + 140 °F)
Ambient temperature range: - 40° to + 60° C (- 40° to + 140° F)
Over-pressure range: 0,03 to 5,5 bar (12" w.c. to 79 Psig)
Under-pressure range: 0,006 to 3,5 bar (2,4" w.c. to 50,76 Psig)
Accuracy class AG: ±5% to 10% for over pressure,
10% to 20% for under pressure
Available sizes DN: 1”- 1” 1/2- 2”
Dilock
Flanges: ANSI 150 RF; threaded NPT and PN 16

The following symbols indicate the application area suggested for each product.
Providing Solutions for Oil and Gas

Solenoid Valves

PVS 782
Pilot-operated high-accuracy safety relief valve

Design pressure: up to 102bar (1479 Psig)


Design temperature range: - 20 °C to +60 °C (-4 to + 140 °F)
Ambient temperature range: - 40° to + 60° C (- 40° to + 140° F)
Set range: 1,5 to 75 bar (21,75 to 1087 Psig)
Accuracy class AG: ± 2%
Available sizes DN: 1” - 2” - 3” - 4”- 6"- 8"
Flanges: ANSI 150/300/600 RF o RTJ; and PN 16
PVS 782

Relief Valves

VS/AM
Spring loaded safety relief valves

...65 Design pressure PS: 20 bar (290 Psig)


Set range: 20 mbar to 7 bar (8" w.c. to 101 Psig)
...58 Design pressure PS: 102 bar (1479 Psig)
Set range: 2 to 44 bar (29 to 638 Psig)

VS/AM 58 VS/AM 65

Accessories

Push
Three way switch valve

Body design pressure: 101 bar (1464 Psig)


Design temperature range: -10 to +50°C (14 to 122°F)
Max working pressure:
- type BP 3.5 bar (50,76 Psig)
- type AP 60 bar (870,22 Psig)

Push

Exploration Distribution Residential and


& Production Transmission & Industrial Commercial 17
For more information please visit our website at: www.fiorentini.com
Valves and Actuators

Ball Valves

Full or reduced bore ball valves

Rating in compliance with ANSI 150/300/ 600/900/1500


Sizes (DN): 1/4” ÷ 36” (15 ÷ 900 mm)
Connections: BSP threaded from DN 1/4” to DN 2”
Flanged from DN 1/2” to DN 36”
ANSI 150/300/600/900/1500 RF-RTJ; PN 16/40/64
Options: manual control; electric, pneumatic
or hydraulic servo-controls.
Split Body Trunnion

Fully Welded Underground

Bar Stock

Butterfly Valves

BF 31 - 32
Butterfly valves with single or dual sealing rings

Design pressure PS: up to 19 bar (275,5 Psig)


Sizes DN: 40 ÷ 1000
Flanges: ANSI 150 RF; PN16
Options: manual control; electric, pneumatic or
hydraulic servo-controls.

...BF32: dual sealing rings on the disk up to DN 250


...BF31: single sealing ring for DN 300 up to DN 1000 BF 31 BF 32

The following symbols indicate the application area suggested for each product.
Providing Solutions for Oil and Gas
Providing Solutions for Oil and Gas

Valves Actuators

PD
Double acting pneumatic actuators

PD actuators are double acting pneumatic devices, suitable for the


operation of quarter turn valves ( ball valves, butterfly valves).

PD2/96 - PD3/96 PD4 - PD4/S - PD5

PDM/PRM
Spring return pneumatic actuators

PDM and PRM actuators are spring return devices, suitable for the
operation of quarter turn valves ( ball valves, butterfly valves).

PDM PRM

Exploration Distribution Residential and


& Production Transmission & Industrial Commercial 19
For more information please visit our website at: www.fiorentini.com
Gas Treatment

Gas Filters

Multi-Cartridge Filters
Cartridge filter for high pressure with quick
closing head
Design pressure: up to 150 bar (2175,51 Psig)
Flanges: ANSI 150/300/600/900 RF - RTJ

FFY : Vertical construction.


FFH : Horizontal construction. FFY FFH

HFA/...TRC
Cartridge filters for high pressure with quick
closure.
Design pressure: up to 100 bar
Flanges: ANSI 300/600 RF - RTJ

HFA/...TRC

HF...
Cartridge filters with high filtering power for
medium pressure with bolted cover
Max allowable pressure: 17,6 bar (255 Psig)
Design temperature range: -15°C + 80°C (5°F to 176°F)
Threaded series connections: UNI-ISO 7/1 1/2" to 2"
Flanged series connections: EN 1092 DN25-32-40-50
HFA/...: in-line inlet/outlet
HFB/...: angle inlet/outlet ...AL HFA
HF-AL: filter with threaded or flanged connections
Max allowable pressure: 10 bar (145 Psig)

HFB

The following symbols indicate the application area suggested for each product.
Providing Solutions for Oil and Gas

Series 10...
Gas filters suitable for all types of natural gas, LPG
or non corrosive gases.
SERIES 10000
Threaded connections UNI-ISO 7/1 1/2"-3/4"
Max allowable pressure: PS 10 bar (145 Psig)
Design temperature range: -15°C + 80°C (5°F to 176°F)
Filtration capacity: 50 micron
10000 102... 106...
SERIES 102.. 106...
Flanged Mod. 10210/F DN150:
max allowable pres.: PS 2 bar (29 Psig)
Design temperature range: -15°C + 80°C (5°F to 176°F)
Filtration capacity: 50 micron
Threaded series connections: UNI-ISO 7/1 1/2" to 2"
Flanged series connections: EN 1092 Sliding flanges DN25-32-40-50
Integral flanges DN65-80-100
Threaded series 106... : max allowable pres.: PS 10 bar (145 Psig)
Flanged series 106.../F : max allowable pres.: PS 10 bar (145 Psig)

Accessories

DP
Differential Pressure Gauge

- DP 1 0 ÷ 150 mbar
- DP 3 0 ÷ 300 mbar
- DP 5 0 ÷ 600 mbar
- DP 10 0 ÷ 1000 mbar

DP

Exploration Distribution Residential and


& Production Transmission & Industrial Commercial 21
For more information please visit our website at: www.fiorentini.com
Gas Treatment

Gas Separators

Separators
Condensate separators for high pressure with quick
closing head.
Flanges: ANSI 150/300/600/900 RF - RTJ

VSV...: Vertical construction


VSH...: Horizontal construction

VSH

Multi Stage Separators


Two-stage condensate separator for high pressures
with quick-closing head.
Design pressure: up to 150 bar
Flanges: ANSI 150/300/600/900 RF - RTJ
API 12J monogrammable

FSY : Vertical construction


FSH : Horizontal construction FSH

The following symbols indicate the application area suggested for each product.
Providing Solutions for Oil and Gas

Heat Exchangers

KSI
Heat exchanger with removable tube bundle

Design pressure: up to 102 bar (1479 Psig)


Flanges: ANSI 300/600 RF - RTJ

KSI

Heaters

GH...
Indirect bath heaters

Indirect bath heaters have a wide variety of successful applications in


the oil and gas production, processing and transmission industry.

The duty of Pietro Fiorentini heaters can vary from 90Kw up to 10Mw.

API 12K monogrammable


GH...

Gas Odorizing Systems

Dosafit
Eletronic odorizing system

OLF
Lapping odorizing system

ODOMATIC
Electronic dosing odorizing pump system
OLF Dosafit

Odomatic

Exploration Distribution Residential and


& Production Transmission & Industrial Commercial 23
For more information please visit our website at: www.fiorentini.com
Gas Metering

Diaphragm Gas Meter

G4 G6

RS/2001 LA
MODEL RS 2,4 RS/2001 LA & AL
Single connection
G1,6 G 2,5 G4 G1,6 G2,5 G4
Clas G6 CEE G4 MID G6 MID CEE and CEE and CEE and CEE and CEE and MID
MID MID MID MID MID
Cyclic volume [dm3] 2,4 2,4 2,4 1,2 1,2 1,2 1,2 1,2 1,2
Maximum flow rate [m3/h] 10 6 10 2,5 4 6 2,5 4 6
Minimum flow rate [m3/h] 0,06 0,04 0,06 0,016 0,025 0,04 0,016 0,025 0,04
Maximum working 0,5 (steel)
[bar] 0,5 0,5 0,5 0,5
pressure 1,6 (aluminium)
Working temperature -25 ÷ + 55 (CEE)
[°C] -25 ÷ +55 -10 ÷ +40 -10 ÷ +40
range -10 ÷ + 40 (MID)
Connections Inches 1" ¼ 1" ¼ 1" ¼ From ¾” to 1”1/4 2"
Distance between 110 – (160 – 250 ) (steel)
mm 250
connections 110 (aluminium)
steel plate,
steel plate, die-cast
Version die-cast steel plate steel plate
aluminium
aluminium

Smart Gas Meter

HyMeter is a hybrid technology commercial meter. It combines


new generation electronical features with a diaphragm metering
gear and a metal body. HyMeter mechanical register is now
replaced by an electronic totalizer equipped with a data
transmission device and a remote firmware upgrade function
HM 4 HM 6

MODEL HM 2,5 HM 4 HM 6 HM 10 MID HM 16 MID HM 25 MID

Cyclic volume [dm3] 1,2 1,2 6 6 6 12


Maximum flow rate [m3/h] 4 6 10 16 25 40
Minimum flow rate [dm3/h] 25 40 60 100 160 250
Maximum working
[bar] 0,1 0,5
pressure
Working temperature
[°C] -25 ÷ +55
range
Connections Inches 1" ¼ 1" ¼ 1" ¼ 1" ¼ - 2" 2" 2" 1/2
steel case with connection interaxis 110 mm

The following symbols indicate the application area suggested for each product.
Providing Solutions for Oil and Gas

Electronic Volume Conversion Device

Explorer FT
Volumetric flow Computer FT is a microcomputer gas flow corrector
designed to measure the line pressure, temperature and the volumes
of the gas. These are used to calculate the appropriate compressibility
equations to compute the real gas flow.

Explorer FT

Explorer Plus
Explorer Plus is designed to optimize installation and maintenance,
it meets the most recent regulations and mantains compatibility with
existing Explorer family product and accessories.

NanoPico is a battery operated remote communication device suitable


to be connected with EVCD Explorer Plus series electronic volume
converter.
Its application is ideal when power supply for remote communication
Nano Pico Explorer Plus is not available on site.

Explorer...
Explorer Mini and Explorer Zero are the new volume correctors
by Pietro Fiorentini designed with a built-in modem that allows the
installation of a single device directly in a ATEX hazardous area.

Explorer Mini Explorer Zero

Floweb
Microprocessor based Flow Computer
Multistream configuration
Approved for custody tranfer service
Suitable for service in combination with orifice (Dp), volumetric or
ultrasonic meters

Floweb

Exploration Distribution Residential and


& Production Transmission & Industrial Commercial 25
For more information please visit our website at: www.fiorentini.com
Gas Metering

Turbine GasFittings
Orefice Meter

Fiomaster
Dual chamber orifice fittings

The classic dual chamber orifice plate, for orifice removal under
pressure now with the advantage of Electroless Nickel Plated body for
a real rust free performance.

Rating: ANSI 150/300/600


Sizes DN: 2" to 24"
Fiomaster

Fiominor
Single chamber orifice fittings

Single chamber orifice fittings available in size range

Rating: up to Class 1500


Sizes DN: 2" to 24"

Fiominor

The following symbols indicate the application area suggested for each product.
Providing Solutions for Oil and Gas

Smart Gas Grid

Smart Gas Solutions

FIO - 2.0
Five-in-One system is a monitor managing and
control unit for pressure regulators.

It can be equipped on both Pilot operated and spring loaded regulators


to enable additional functionalities like:
Indirect flow measurement
Flow limitation
Pressure profiling by time or real time demand based
FIO - 2.0 Process monitoring

Information and Actions

Alarm Management
& Data Aquisition
We monitor the plants continuously, automatically
and promptly reporting any anomalies, being able to
take care of on site emergencies.

Exploration Distribution Residential and


& Production Transmission & Industrial Commercial 27
For more information please visit our website at: www.fiorentini.com
Stations

Complete Units

From components to
complete units
Creating a different approach in handling sophisticated
projects is our target.  We have the ambition of being a
single interface covering all the different aspects of the
projects, irrelevantly of the sophistication. An unique
“single stop” concept resulting in a  perfect and easy
project monitoring in all phases.

Residential Small commercial


connections connections

Smart Stations

NEW!
Fio Cube Ultra compact prefabricated reducing
100 n 200 n 600 stations for capacities up to 1000 Sm3/h

Main components:
n SQD regulator with token relief valve and optional
incorporated slam shut valve
n Inlet and Outlet Butterfly valve
n Cartridge G2 filter with connections on the cover suitable for
monitoring pressure drop and inlet pressure
Providing Solutions for Oil and Gas

Gas Processing Plants

From the wellhead to the


daily gas utilization.
Creating a different approach in handling sophisticated
projects is our target.  We have the ambition of being
a single interface covering all the different aspects of
the projects, regardless of the sophistication. An unique
“single stop” concept resulting in a  perfect and easy
project monitoring in all phases.

Enclosed District
Stations Skid mounted units HIPPS

Flowatch Multiphase Flow Meter

Power Plants
City Gate
Underground Storage

29
For more information please visit our website at: www.fiorentini.com
Services

A New perspective:
Fiorentini Services

We offer the advantage of being a single reference for supporting you continuously long all phases
involved by gas installations.
From their conception, to their implementation and ultimately to their everyday use with a wide range
of Service solutions:

IInstallation and start up


On site Surveys
Maintenance and Emergency services
Plants and components removal and disposal.
Supplying and Handling of Odorisation Systems
Metering devices: installations, commissioning,
maintenance and disposal of metering devices
Cathodic Protection Monitoring
Spare Parts availability
Providing Solutions for Oil and Gas

Professional
Training Courses
Pietro Fiorentini offers a training service for its customers.
The course can be carried out both for technicians responsible
for running/managing natural gas transport and distribution
systems and for equipment maintenance engineers.

We offer customized trainings to be done directly to your


premises or in Pietro Fiorentini S.p.A. headquarter, we adapt
the training program to specific gas companies needs.

31
For more information please visit our website at: www.fiorentini.com
www.fiorentini.com

The data are not binding. We reserve


the right to make changes without prior
notice.

FP516-E-b

QR code generated on http://qrcode.littleidiot.be

You might also like