Fiche Technique Unité Roof Top

Download as pdf or txt
Download as pdf or txt
You are on page 1of 29

22-1796-14

Product Data
4TCY4024 through 4TCY4060
Single Packaged Convertible Cooling
14 SEER
2 - 5 Ton
R-410A

© 2013 Trane Pub. No. 22-1796-14


It's Hard to Stop a Trane.
Single Packaged Cooling System
Trane offers a complete family of cooling systems, designed to give you the unbeat-
able combination of energy efficiency and lower operating costs.

Introducing the new TRANE Single Packaged Cooling System.


Single Packaged Cooling Systems are easy better performance. Our single packaged
and versatile to install. Because cooling and air conditioners offer cooling efficiencies
air handling functions are all contained in a that are unmatched in the industry and
single cabinet, a Trane packaged air condi- provide you with a product far superior in
tioner is easy to install and service. It can be performance than the competition.
flush mounted beside your home at ground
level or placed on the roof for horizontal or
downflow installation. When connected to
an optional Trane thermostat control, and
air distribution ducts, you have a highly ef-
ficient, total home comfort system.
Single Packaged Cooling Systems provide

2
Contents
Optional Equipment Listing 4

General Data 5

Heater Data 8

SPEK Data 9

Performance Data

Indoor Fan 12

Typical Wiring 15

Optional Equipment 18

Dimensional Data 23

Mechanical Specifications 29

3
Optional Equipment

OPTIONAL EQUIPMENT FOR PACKAGED UNITS (check mark [3] indicates accessories included)

Hinged Filter Access Door (4TCY4024-036) ....................................................................... BAYACCDOR1A[ ]


Hinged Filter Access Door (4TCY4042-060) ....................................................................... BAYACCDOR2A[ ]
Roof Curb Full Perimeter (4TCY4024-36) 3 .......................................................................BAYCURB050A[ ]
Roof Curb Full Perimeter (4TCY4042-060) 3 .....................................................................BAYCURB051A[ ]
Roof Curb Utility Extension Kit (BAYCURB050A)....................................................................BAYUTIL101B[ ]
Roof Curb Utility Extension Kit (BAYCURB051A)....................................................................BAYUTIL102B[ ]
0-25% Manual Fresh Air Damper (4TCY4024-36) 1............................................................BAYOSAH001A[ ]
0-25% Manual Fresh Air Damper (4TCY4042-060) 1..........................................................BAYOSAH002A[ ]
Motorized Fresh Air Damper (4TCY4024-36) 1................................................................. BAYDMPR101A[ ]
Motorized Fresh Air Damper (4TCY4042-060) 1................................................................ BAYDMPR102A[ ]
16" Round Duct Adapter (2 per box) (4TCY4024-36) 6 ..................................................... BAYSQRD001A[ ]
18" Round Duct Adapter (2 per box) (4TCY4024-060) 6 ................................................... BAYSQRD002A[ ]
0-100% Mod Economizer w/Baro. Relief (4TCY4024-36) 24 ........................................... BAYECON101B[ ]
0-100% Mod. Economizer w/Baro. Relief (4TCY4042-060A) 124.................................... BAYECON102B[ ]
0-100% Horizontal Economizer (4TCY4024-36) 12 ......................................................... BAYECON200A[ ]
0-100% Horizontal Economizer (4TCY4042-060) 12 ....................................................... BAYECON201A[ ]
Enthalpy Control for Economizer (solid state)........................................................................ BAYENTH001A[ ]
Remote Potentiometer (All-BAYECON***A)..............................................................................BAYSTAT023[ ]
1"-2" Filter Frame (4TCY4024-36) (20 x 25 filter not included) 1.............. BAYFLTR101B[ ]
1"-2" Filter Frame (4TCY4042-060) (20 x 20 & 20 x18 filter not included) 1.. ...... BAYFLTR201B[ ]
Head Pressure Control (Low Ambient Cool) (208/240v) Kit 5. ............................................BAYLOAM105A[ ]
Quick Start Kit (4TCY4-‡1).................................................................................................... BAYKSKT300A[ ]
Crankcase Heater Recip (4TCY4024‡1 (230v) 5................................................................BAYCCHT101A[ ]
Crankcase Heater Scroll (4TCY4036-060‡1/3)(230v) 5......................................................BAYCCHT102A[ ]
Adapter Curb 4TCY4024-36 to BAYCURB030,38................................................................ BAYADAP050A[  ]
Adapter Curb 4TCY4024-36 to BAYCURB033..................................................................... BAYADAP051A[  ]
Adapter Curb 4TCY4042-060 to BAYCURB030,38.............................................................. BAYADAP052A[  ]
Adapter Curb 4TCY4042-060 to BAYCURB033................................................................... BAYADAP053A[  ]
Adapter Curb 4TCY4042-060 to BAYCURB034................................................................... BAYADAP054A[ ]
12" Duct Shroud Covers Horizontal 4TCY4024-0607..........................................................BAYCOVR112A[ ]
18" Duct Shroud Covers Horizontal 4TCY4024-060 7.........................................................BAYCOVR118A[ ]
Extreme Condition Mounting Kit - All BAYCURB & BAYADAP..............................................BAYEXMK001A[ ]
Extreme Condition Mounting Kit - All BAYUTIL.....................................................................BAYEXMK002B[ ]
Extreme Condition Mounting Kit - All Slab Mounts................................................................BAYEXMK003A[ ]
Lifting Lug Kit............................................................................................................................BAYLlFT002B[ ]
SUPPLEMENTARY HEATERS (1 PHASE)
3.76/5.0 KW Heater (208/240V 1PH) (4TCY4024-060‡1).................................................... BAYHTRV105E[ ]
3.76/5.0 KW Heater (208/240V 1PH) (4TCY4024-060‡1).................................................... BAYHTRV108E[ ]
7.50/10.0 KW Heater (208/240V 1PH) (4TCY4024-060‡1).................................................. BAYHTRV110E[ ]
11.27/15.00 KW Heater (208/240V 1PH) (4TCY4030-060‡1).............................................. BAYHTRV115E[ ]
15.0/20.0 KW Heater (208/240V 1PH) (*4TCY4042-060‡1)................................................. BAYHTRV120E[ ]
18.78/25.0 KW Heater (208/240V 1PH) (4TCY4042-060‡1)................................................. BAYHTRV125E[ ]
SUPPLEMENTARY HEATERS (3 PHASE)
3.76/5.0 KW Heater (208/240V 3PH) (4TCY4036-060‡3).................................................... BAYHTRV305E[ ]
3.76/5.0 KW Heater (208/240V 3PH) (4TCY4036-060‡3).................................................... BAYHTRV308E[ ]
7.50/10.0 KW Heater (208/240V 3PH) (4TCY4024-48‡3).................................................... BAYHTRV310E[ ]
11.27/15.00 KW Heater (208/240V 3PH) (4TCY4036-060‡3).............................................. BAYHTRV315E[ ]
15.00/20.0 KW Heater (208/240V 3PH) (4TCY4048-060‡3)................................................ BAYHTRV320E[ ]
18.78/25.0 KW Heater (208/240V 3PH) (4TCY4048-060‡3)................................................. BAYHTRV325E[ ]
Single Power Entry Kit 8 ...................................................................................................... BAYSPEK060F[ ]
Single Power Entry Kit 8 ...................................................................................................... BAYSPEK061E[ ]
Single Power Entry Kit 8 ...................................................................................................... BAYSPEK062F[ ]
Single Power Entry Kit 8 ...................................................................................................... BAYSPEK063F[ ]
Single Power Entry Kit 8 ...................................................................................................... BAYSPEK064E[ ]
Single Power Entry Kit 8 ...................................................................................................... BAYSPEK065E[ ]

NOTES: 1 Must use internal filter frame when economizer or fresh air kit is used.
2 Dry bulb control standard with economizer.
3 Ships knocked down.
4 Downflow only.
5 Low Ambient cooling requires crankcase heater (BAYCCHT----B).
6 It is the responsibility of the installing dealer to properly size the ductwork for each specific application.
7 BAYCOVR112,118A will not cover BAYSQRD002A applications.
8 See table on page 8 for matching kit with units and heaters.
‡ = A or B

4
General Data
MODEL 4TCY4024A1000B 4TCY4030A1000B 4TCY4036B1000B
RATED Volts/PH/Hz 208-230/1/60 208-230/1/60 208-230/1/60
Performance Cooling BTUH 23400 30000 38000
Indoor Airflow (CFM) 780 900 1195
Power Input (KW) 1.99 2.5 3.17
EER/SEER (BTU/Watt-Hr.) 12 / 14.0 12.0 / 14.0 12.0 / 14.2
Sound Power Rating [dB(A)] 68 71 69
POWER CONN.—V/Ph/Hz 208-230/1/60 208-230/1/60 208-230/1/60
Min. Brch. Cir. Ampacity 16.5 19.1 26.3
Fuse Size — Max. (amps) 25 30 40
Fuse Size — Recmd. (amps) 25 30 40
COMPRESSOR RECIPROCATING RECIPROCATING SCROLL
Volts/Ph/Hz 200-230/1/60 208-230/1/60 208-230/1/60
R.L. Amps — L.R. Amps 8.3 / 57.8 11.1 / 63 16.7 / 69
OUTDOOR COIL — TYPE SPINE-FIN SPINE-FIN SPINE-FIN
Rows/F.P.I. 2 / 24 2 / 24 2 / 24
Face Area (sq.ft.) 13.32 13.32 15.49
Tube Size (in.) 3/8 3/8 3/8
INDOOR COIL — TYPE PLATE FIN PLATE FIN PLATE FIN
Rows/F.P.I. 3 / 15 3 / 15 4 / 15
Face Area (sq.ft.) 3.54 3.54 3.54
Tube Size (in.) 3/8 3/8 3/8
Refrigerant Control EXPANSION VALVE EXPANSION VALVE EXPANSION VALVE
Drain Conn. Size (in.) 3/4 FEMALE NPT 3/4 FEMALE NPT 3/4 FEMALE NPT
OUTDOOR FAN — TYPE PROPELLER PROPELLER PROPELLER
Dia. (in.) 23.4 23.4 23.4
Drive/No. Speeds DIRECT / 1 DIRECT / 1 DIRECT / 1
CFM @ 0.0 in. w.g. 2560 2550 3300
Motor — HP/R.P.M. 1/12 / 810 1/6 / 830 1/5 / 830
Volts/Ph/Hz 230/1/60 208-230/1/60 230/1/60
F.L. Amps/L.R. Amps 0.54 / 0.95 0.9 / 1.7 1.1 / 1.9
INDOOR FAN — TYPE CENTRIFUGAL CENTRIFUGAL CENTRIFUGAL
Dia x Width (in.) 10 X 10 10 X 10 10 X 10
Drive/No. Speeds DIRECT / VARIABLE DIRECT / VARIABLE DIRECT / VARIABLE
CFM @ 0.0 in. w.g. SEE FAN PERFORMANCE TABLE SEE FAN PERFORMANCE TABLE SEE FAN PERFORMANCE TABLE
Motor — HP/R.P.M. 1/2 / VARIABLE 1/2 / VARIABLE 1/2 / VARIABLE
Volts/Ph/Hz 200-230/1/60 208-230/1/60 200-230/1/60
F.L. Amps/L.R. Amps 4.3 / 4.3 4.3 / 4.3 4.3 / 4.3
FILTER / FURNISHED NO NO NO
Type Recommended THROWAWAY THROWAWAY THROWAWAY
Recmd. Face Area (sq. ft.) 4.0 4.0 4
REFRIGERANT R410A R410A R410A
Charge (lbs.) 6.0 6.30 7.80
DIMENSIONS HXWXL HXWXL HXWXL
Crated (in.) 45.86 / 44.5 / 52.03 45.86 / 44.5 / 52.03 47.86 / 44.5 / 52.03
WEIGHT
Shipping (lbs.) / Net (lbs.) 444 / 348 444 / 348 450 / 354

1 Rated in accordance with AHRI Standard 210/240.


2 Sound Power values are not adjusted for ARI 270-95 tonal corrections.
3 Calculated in accordance with currently prevailing Nat'l Electrical
Code.

4 Standard Air — Dry Coil — Outdoor.


5 Standard Air — Wet Coil — Indoor.
6 Rated in accordance with D.O.E. test procedure.
7 Filters must be installed in return air system. Square footages listed are
based on 300 f.p.m. face velocity. If permanent filters are used size per
manufacturer's recommendations with clean resistance of 0.05" W.C.

5
General Data
MODEL 4TCY4036B3000A 4TCY4042B1000B 4TCY4048B1000B
RATED Volts/PH/Hz 208-230/3/60 208-230/1/60 208-230/1/60
Performance Cooling BTUH 37000 42000 48500
Indoor Airflow (CFM) 1195 1420 1605
Power Input (KW) 3.17 3.5 4.041
EER/SEER (BTU/Watt-Hr.) 12.0 / 14.2 12.0 / 14.25 12 / 14.2
Sound Power Rating [dB(A)] 69 74 72
POWER CONN.—V/Ph/Hz 208-230/3/60 208-230/1/60 208-230/1/60
Min. Brch. Cir. Ampacity 18.4 30.7 35.5
Fuse Size — Max. (amps) 25 45 50
Fuse Size — Recmd. (amps) 25 45 50
COMPRESSOR SCROLL SCROLL SCROLL
Volts/Ph/Hz 208-230/3/60 208-230/1/60 208-230/1/60
R.L. Amps — L.R. Amps 10.4 / 73 17.9 / 112 21.8 / 117
OUTDOOR COIL — TYPE SPINE-FIN SPINE-FIN SPINE-FIN
Rows/F.P.I. 2 / 24 2 / 24 2 / 24
Face Area (sq.ft.) 15.49 18.01 18.01
Tube Size (in.) 3/8 3/8 3/8
INDOOR COIL — TYPE PLATE FIN PLATE FIN PLATE FIN
Rows/F.P.I. 4 / 15 3 / 15 3 / 15
Face Area (sq.ft.) 3.54 5 5.0
Tube Size (in.) 3/8 3/8 3/8
Refrigerant Control EXPANSION VALVE EXPANSION VALVE EXPANSION VALVE
Drain Conn. Size (in.) 3/4 FEMALE NPT 3/4 FEMALE NPT 3/4 FEMALE NPT
OUTDOOR FAN — TYPE PROPELLER PROPELLER PROPELLER
Dia. (in.) 23.4 28.2 28.2
Drive/No. Speeds DIRECT / 1 DIRECT / 1 DIRECT / 1
CFM @ 0.0 in. w.g. 3260 4460 4460
Motor — HP/R.P.M. 1/5 / 830 1/4 / 825 1/4 / 825
Volts/Ph/Hz 230/1/60 208-230/1/60 230/1/60
F.L. Amps/L.R. Amps 1.1 / 1.9 1.4 / 3.4 1.4 / 3.37
INDOOR FAN — TYPE CENTRIFUGAL CENTRIFUGAL CENTRIFUGAL
Dia x Width (in.) 10 X 10 11 X 10 10 X 10
Drive/No. Speeds DIRECT / VARIABLE DIRECT / VARIABLE DIRECT / VARIABLE
CFM @ 0.0 in. w.g. SEE FAN PERFORMANCE TABLE SEE FAN PERFORMANCE TABLE SEE FAN PERFORMANCE TABLE
Motor — HP/R.P.M. 1/2 / VARIABLE 3/4 / VARIABLE 3/4 / VARIABLE
Volts/Ph/Hz 200-230/1/60 208-230/1/60 200-230/1/60
F.L. Amps/L.R. Amps 4.3 / 4.3 6.8 / 6.8 6.8 / 6.8
FILTER / FURNISHED NO NO NO
Type Recommended THROWAWAY THROWAWAY THROWAWAY
Recmd. Face Area (sq. ft.) 4 5.3 5.3
REFRIGERANT R410A R410A R410A
Charge (lbs.) 7.80 7.00 8.30
DIMENSIONS HXWXL HXWXL HXWXL
Crated (in.) 47.86 / 44.5 / 52.03 47.86 / 47.4 / 61.75 47.86 / 47.4 / 61.75
WEIGHT
Shipping (lbs.) / Net (lbs.) 450 / 354 607 / 479 623 / 495

1 Rated in accordance with AHRI Standard 210/240.


2 Sound Power values are not adjusted for AHRI 270-95 tonal cor-
rections.

3 Calculated in accordance with currently prevailing Nat'l Electrical


Code.

4 Standard Air — Dry Coil — Outdoor.


5 Standard Air — Wet Coil — Indoor.
6 Rated in accordance with D.O.E. test procedure.
7 Filters must be installed in return air system. Square footages listed are
based on 300 f.p.m. face velocity. If permanent filters are used size per
manufacturer's recommendations with clean resistance of 0.05" W.C.

6
General Data
MODEL 4TCY4048B3000A 4TCY4060A1000B 4TCY4060A3000B
RATED Volts/PH/Hz 208-230/3/60 208-230/1/60 208-230/3/60
Performance Cooling BTUH 48500 60000 60000
Indoor Airflow (CFM) 1605 1800 1800
Power Input (KW) 4.041 4.93 4.93
EER/SEER (BTU/Watt-Hr.) 12.0 / 14.2 12.0 / 14.0 12.0 / 14.0
Sound Power Rating [dB(A)] 72 76 76
POWER CONN.—V/Ph/Hz 208-230/3/60 208-230/1/60 208-230/3/60
Min. Brch. Cir. Ampacity 25.3 41.6 28.6
Fuse Size — Max. (amps) 35 60 40
Fuse Size — Recmd. (amps) 35 60 40
COMPRESSOR SCROLL SCROLL SCROLL
Volts/Ph/Hz 208-230/3/60 208-230/1/60 208-230/3/60
R.L. Amps — L.R. Amps 13.7 / 83.1 26.4 / 134 16.0 / 110
OUTDOOR COIL — TYPE SPINE-FIN SPINE-FIN SPINE-FIN
Rows/F.P.I. 2 / 24 2 / 24 2 / 24
Face Area (sq.ft.) 18.01 23.57 23.57
Tube Size (in.) 3/8 3/8 3/8
INDOOR COIL — TYPE PLATE FIN PLATE FIN PLATE FIN
Rows/F.P.I. 3 / 15 4 / 15 4 / 15
Face Area (sq.ft.) 5.0 5.0 5.0
Tube Size (in.) 3/8 3/8 3/8
Refrigerant Control EXPANSION VALVE EXPANSION VALVE EXPANSION VALVE
Drain Conn. Size (in.) 3/4 FEMALE NPT 3/4 FEMALE NPT 3/4 FEMALE NPT
OUTDOOR FAN — TYPE PROPELLER PROPELLER PROPELLER
Dia. (in.) 28.2 28.2 28.2
Drive/No. Speeds DIRECT / 1 DIRECT / 1 DIRECT / 1
CFM @ 0.0 in. w.g. 4460 5720 5720
Motor — HP/R.P.M. 1/4 / 825 1/3 / 825 1/3 / 825
Volts/Ph/Hz 230/1/60 230/1/60 230/1/60
F.L. Amps/L.R. Amps 1.4 / 3.37 1.7 / 3.5 1.7 / 3.5
INDOOR FAN — TYPE CENTRIFUGAL CENTRIFUGAL CENTRIFUGAL
Dia x Width (in.) 10 X 10 11 X 10 11 X 10
Drive/No. Speeds DIRECT / VARIABLE DIRECT / VARIABLE DIRECT / VARIABLE
CFM @ 0.0 in. w.g. SEE FAN PERFORMANCE TABLE SEE FAN PERFORMANCE TABLE SEE FAN PERFORMANCE TABLE
Motor — HP/R.P.M. 3/4 / VARIABLE 1 / VARIABLE 1 / VARIABLE
Volts/Ph/Hz 200-230/1/60 208-230/1/60 208-230/1/60
F.L. Amps/L.R. Amps 6.8 / 6.8 6.9 / 6.9 6.9 / 6.9
FILTER / FURNISHED NO NO NO
Type Recommended THROWAWAY THROWAWAY THROWAWAY
Recmd. Face Area (sq. ft.) 5.3 5.3 5.3
REFRIGERANT R410A R410A R410A
Charge (lbs.) 8.30 10.10 10.10
DIMENSIONS HXWXL HXWXL HXWXL
Crated (in.) 47.86 / 47.4 / 61.75 51.86 / 47.4 / 61.75 51.86 / 47.4 / 61.75
WEIGHT
Shipping (lbs.) / Net (lbs.) 607 / 479 612 / 484 612 / 484

1 Rated in accordance with AHRI Standard 210/240.


2 Sound Power values are not adjusted for AHRI 270-95 tonal cor-
rections.

3 Calculated in accordance with currently prevailing Nat'l Electrical


Code.

4 Standard Air — Dry Coil — Outdoor.


5 Standard Air — Wet Coil — Indoor.
6 Rated in accordance with D.O.E. test procedure.
7 Filters must be installed in return air system. Square footages listed are
based on 300 f.p.m. face velocity. If permanent filters are used size per
manufacturer's recommendations with clean resistance of 0.05" W.C.

7
Heater Data
4TCY4024 to 4TCY4060 Heater Data

HEATER CAPACITY KW/STAGE MAX FUSE OR CANADA ONLY


ELECTRIC RATED NO. OF
UNIT MODEL PHASE AMPS MCA HACR CKT MAX. CKT BKR
HEATER MODEL VOLTAGE STAGES
KW BTUH 1 2 BKR SIZE (4) SIZE (5)

^W/TC*3018-060‡1
^W/TCY4024-060‡1 BAYHTRV105E 208/240 1 18/21 3.76/5.0 12800/17100 1 3.76/5.0 23/26 25/30 25/30
^WCZ6036-060‡1
^W/TC*3018-060‡1
^W/TCY4024-060‡1 BAYHTRV108E 208/240 1 29/33 6.0/8.0 20500/27300 1 6.0/8.0 36/41 40/45 40/45
^WCZ6036-060‡1
^W/TC*3024-060‡1
^W/TCY4024-060‡1 BAYHTRV110E 208/240 1 36/42 7.5/10.0 25600/34100 1 7.5/10.0 45/52 45/60 45/60
^WCZ6036-060‡1
^W/TC*3030-060‡1
^W/TCY4030-060‡1 BAYHTRV115E# 208/240 1 54/63 11.27/15.0 38500/51200 2 7.5/10.0 3.76/5.0 68/78 70/80 70/80
^WCZ6036-060‡1
^W/TC*3042-060‡1
^W/TCY4042-060‡1 BAYHTRV120E# 208/240 1 72/83 15.0/20.0 51200/68300 2 7.5/10.0 7.5/10.0 90/104 90/110 90/110
^WCZ6048-060‡1
4WC*3042‡1
^W/TC*3060‡1
BAYHTRV125E# 208/240 1 90/104 18.78/25.0 64100/85300 2 11.26/15.0 7.5/10.0 113/130 125/150 125/150
^W/TCY4042-060‡1
^WCZ6048-060‡1

^W/TC*3036-060‡3
^W/TCY4036-060‡3 BAYHTRV305E 208/240 3 10/12 3.76/5.0 12800/17100 1 3.76/5.0 13/15 15/15 15/15
^WCZ6036-060‡3
^W/TC*3036-060‡3
^W/TCY4036-060‡3 BAYHTRV308E 208/240 3 17/19 6.0/8.0 20500/27300 1 6.0/8.0 21/24 25/25 25/25
^WCZ6036-060‡3
^W/TC*3036-060‡3
^W/TCY4036-060‡3 BAYHTRV310E 208/240 3 21/24 7.5/10.0 25600/34100 1 7.5/10.0 26/30 30/30 30/30
^WCZ6036-060‡3
^W/TC*3036-060‡3
^W/TCY4036-060‡3 BAYHTRV315E 208/240 3 31/36 11.27/15.0 38500/51200 2 7.5/10.0 3.76/5.0 39/45 40/45 40/45
^WCZ6036-060‡3
^W/TC*3048-060‡3
^W/TCY4048-060‡3 BAYHTRV320E 208/240 3 42/48 15.0/20.0 51200/68300 2 7.5/10.0 7.5/10.0 52/60 60/60 60/60
^WCZ6048-060‡3
^W/TC*3060‡3
^W/TCY4048-060‡3 BAYHTRV325E# 208/240 3 52/60 18.78/25.0 64100/85300 2 11.26/15.0 7.5/10.0 65/75 70/80 70/80
^WCZ6048-060‡3
^W/TC*3036-060‡4
BAYHTRV405E 480 3 6 5.0 17100 1 5.0 8 15 15
^WCZ6036-060‡4

^W/TC*3036-060‡4
BAYHTRV408E 480 3 10 8.0 27300 1 8.0 13 15 15
^WCZ6036-060‡4
^W/TC*3036-060‡4
BAYHTRV410E 480 3 12 10.0 34100 1 10.0 15 15 15
^WCZ6036-060‡4

^W/TC*3036-060‡4
BAYHTRV415E 480 3 18 15.0 51200 2 10.0 5.0 23 25 25
^WCZ6036-060‡4
^W/TC*3048-060‡4
BAYHTRV420E 480 3 24 20.0 68300 2 10.0 10.0 30 30 30
^WCZ6048-060‡4
^W/TC*3060‡4
BAYHTRV425E 480 3 30 25.0 85300 2 15.0 10.0 38 40 40
^WCZ6048-060‡4

General Table Notes:


Any power supply and circuits must be wired and protected in accordance with local electrical codes.
2 The MCA values listed are for electric heater only.
Field wire must be rated at least 75°C
4 The HACR circuit breaker is for U.S.A. installations only.
5 For Canada installation reference only.
# Heater uses fuses.

Unit Model Notes:


^ = 2 or 4
* = C or X
‡ = A or B

8
Single Power Entry Kit Data

Notes:
* = C or X
‡ = A or B

9
Single Power Entry Kit Data

Notes:
* = C or X
‡ = A or B

10
Single Power Entry Kit Data

Notes:
* = C or X
‡ = A or B

11
Indoor Blower Performance
Indoor Fan Performance (230v) 4TCY4024 (230vperformance)
Horizontal Airflow
4TCY4024-HOR DIPSWITCH SETTINGS External Static Pressure (in. wg)

AIRFLOW SETTING 1 2 3 4 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0

Watts 52 66 89 115 140 164 186 206 229 259 -


350 CFM/TON OFF OFF OFF ON
CFM 706 716 727 733 731 719 700 679 662 659 -

Watts 72 94 120 148 177 207 233 254 267 290 -


400 CFM/TON* OFF OFF OFF OFF
CFM 786 793 805 813 813 806 793 780 778 799 -
Watts 80 99 125 153 182 211 243 284 342 - -
450 CFM/TON OFF OFF ON OFF
CFM 860 862 877 892 903 904 897 884 869 - -
Down Airflow
4TCY4024-DOWN DIPSWITCH SETTINGS External Static Pressure (in. wg)

AIRFLOW SETTING 1 2 3 4 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0

Watts 35 70 90 108 131 160 188 204 225 250 -


350 CFM/TON OFF OFF OFF ON
CFM 695 729 734 728 721 715 705 679 680 685 -

Watts 79 87 105 129 155 180 206 232 264 306 -


400 CFM/TON* OFF OFF OFF OFF
CFM 846 807 802 810 816 813 803 794 800 846 -

Watts 86 102 127 156 185 213 242 275 319 - -


450 CFM/TON OFF OFF ON OFF
CFM 884 870 882 899 909 907 895 886 898 - -

Indoor Fan Performance (230v) 4TCY4030 (230vperformance)


Horizontal Airflow
4TCY4030-HOR DIPSWITCH SETTINGS External Static Pressure (in. wg)

AIRFLOW SETTING 1 2 3 4 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0

Watts - 106 135 164 193 220 247 275 306 - -


350 CFM/TON OFF OFF OFF ON
CFM - 860 887 901 907 905 899 887 870 - -

Watts - 136 172 199 226 256 288 316 329 - -


400 CFM/TON* OFF OFF OFF OFF
CFM - 972 996 1001 1000 1000 999 988 951 - -

Watts - 182 218 251 283 317 351 381 - - -


450 CFM/TON OFF OFF ON OFF
CFM - 1108 1113 1119 1121 1119 1115 1119 - - -

Down Airflow
4TCY4030-DOWN DIPSWITCH SETTINGS External Static Pressure (in. wg)

AIRFLOW SETTING 1 2 3 4 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0

Watts - 109 133 162 190 214 234 259 298 - -


350 CFM/TON OFF OFF OFF ON
CFM - 856 867 875 876 869 855 842 838 - -

Watts - 134 174 200 222 247 276 306 328 - -


400 CFM/TON* OFF OFF OFF OFF
CFM - 960 987 980 968 965 966 952 884 - -

Watts - 184 216 254 289 318 343 375 - - -


450 CFM/TON OFF OFF ON OFF
CFM - 1087 1094 1103 1107 1105 1098 1091 - - -

*Factory Default Setting

12
Indoor Blower Performance
Indoor Fan Performance (230v) 4TCY4036 (230vperformance)
Horizontal Airflow
4TCY4036-HOR DIPSWITCH SETTINGS External Static Pressure (in. wg)
AIRFLOW SETTING 1 2 3 4 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
Watts 162 173 197 226 256 285 313 343 360 - -
350 CFM/TON OFF OFF OFF ON
CFM 1058 1062 1063 1063 1062 1060 1057 1053 1010 - -
Watts 179 230 265 296 329 366 403 431 436 - -
400 CFM/TON* OFF OFF OFF OFF
CFM 1179 1196 1204 1206 1205 1203 1199 1194 1185 - -
Watts 318 336 365 399 435 469 502 533 - - -
450 CFM/TON OFF OFF ON OFF
CFM 1390 1376 1370 1366 1361 1354 1349 1351 - - -

Down Airflow
4TCY4036-DOWN DIPSWITCH SETTINGS External Static Pressure (in. wg)
AIRFLOW SETTING 1 2 3 4 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
Watts 169 182 210 243 273 301 331 370 433 - -
350 CFM/TON OFF OFF OFF ON
CFM 1025 1062 1068 1063 1060 1061 1064 1055 1015 - -
Watts 225 253 283 315 348 381 414 449 484 - -
400 CFM/TON* OFF OFF OFF OFF
CFM 1187 1201 1203 1201 1198 1197 1194 1184 1157 - -
Watts 339 357 390 424 455 483 516 571 - - -
450 CFM/TON OFF OFF ON OFF
CFM 1391 1377 1377 1375 1366 1352 1344 1360 - -

Indoor Fan Performance (230v) 4TCY4042 (230vperformance)


Horizontal Airflow
4TCY4042-HOR DIPSWITCH SETTINGS External Static Pressure (in. wg)
AIRFLOW SETTING 1 2 3 4 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
OFF OFF OFF ON Watts - 181 211 241 270 298 327 355 382 408 -
350 CFM/TON
CFM - 1248 1250 1253 1254 1249 1240 1225 1209 1195 -
OFF OFF OFF OFF Watts - 261 296 325 352 380 411 444 477 509 -
400 CFM/TON*
CFM - 1444 1448 1441 1429 1417 1407 1400 1394 1386 -
OFF OFF ON OFF Watts - 353 390 426 462 499 536 573 609 645 -
450 CFM/TON
CFM - 1608 1611 1613 1613 1612 1608 1603 1597 1590

Down Airflow
4TCY4042-DOWN DIPSWITCH SETTINGS External Static Pressure (in. wg)
AIRFLOW SETTING 1 2 3 4 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
OFF OFF OFF ON Watts - 195 229 258 283 308 335 362 390 415 -
350 CFM/TON
CFM - 1240 1244 1245 1243 1238 1229 1217 1203 1189 -
OFF OFF OFF OFF Watts - 289 312 341 371 402 432 461 491 523 -
400 CFM/TON*
CFM - 1433 1422 1415 1411 1405 1399 1392 1383 1377 -
OFF OFF ON OFF Watts - 385 422 457 491 527 563 600 636 670 -
450 CFM/TON
CFM - 1604 1602 1600 1598 1596 1593 1590 1585 1578

*Factory Default Setting

13
Indoor Blower Performance
Indoor Fan Performance (230v) 4TCY4048 (230vperformance)
Horizontal Airflow
4TCY4048-HOR DIPSWITCH SETTINGS External Static Pressure (in. wg)
AIRFLOW SETTING 1 2 3 4 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
Watts 187 232 264 291 318 347 379 413 446 472 -
350 CFM/TON OFF OFF OFF ON
CFM 1355 1387 1396 1392 1382 1370 1360 1351 1341 1326 -
Watts 315 324 352 389 428 464 498 529 563 606 -
400 CFM/TON* OFF OFF OFF OFF
CFM 1603 1581 1577 1580 1583 1583 1577 1567 1558 1556 -
Watts 301 431 507 552 584 615 651 694 739 779 -
450 CFM/TON OFF OFF ON OFF
CFM 1752 1794 1812 1816 1812 1806 1800 1797 1793 1785

Down Airflow
4TCY4048-DOWN DIPSWITCH SETTINGS External Static Pressure (in. wg)
AIRFLOW SETTING 1 2 3 4 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
Watts 208 254 284 312 343 379 414 437 460 490 -
350 CFM/TON OFF OFF OFF ON
CFM 1337 1393 1398 1388 1383 1390 1399 1384 1380 1370 -
Watts 302 349 386 423 465 509 552 583 599 628 -
400 CFM/TON* OFF OFF OFF OFF
CFM 1574 1580 1585 1589 1594 1598 1601 1597 1584 1556 -
Watts 501 523 555 592 631 672 714 760 800 845 -
450 CFM/TON OFF OFF ON OFF
CFM 1847 1823 1817 1818 1820 1819 1817 1820 1815 1810

Indoor Fan Performance (230v) 4TCY4060 (230vperformance)

Horizontal Airflow
4TCY4060A-HOR DIPSWITCH SETTINGS External Static Pressure (in. wg)
AIRFLOW SETTING 1 2 3 4 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
Watts 394 427 464 504 548 591 633 668 - - -
350 CFM/TON OFF OFF OFF ON
CFM 1673 1772 1799 1793 1779 1771 1767 1756 - - -
Watts 695 642 660 710 764 811 849 893 966 1108 -
400 CFM/TON* OFF OFF OFF OFF
CFM 2054 2036 2031 2032 2033 2031 2023 2012 2002 2000 -

Down Airflow
4TCY4060A-DOWN DIPSWITCH SETTINGS External Static Pressure (in. wg)
AIRFLOW SETTING 1 2 3 4 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
Watts 443 461 493 532 571 607 642 680 - - -
350 CFM/TON OFF OFF OFF ON
CFM 1796 1741 1726 1725 1722 1712 1698 1692 - - -
Watts 740 697 715 763 819 866 892 894 872 835 -
400 CFM/TON* OFF OFF OFF OFF
CFM 2010 1987 1979 1977 1976 1969 1950 1913 1852 1759 -

*Factory Default Setting

14
Indoor Blower Performance
4TCY4024 AIRFLOW WITH AUXILIARY HEAT (CFM)
COOLING FAN DELAY OPTIONS
SWITCH SETTINGS SELECTION NOMINAL AIRFLOW
7-OFF 8-OFF LOW 700 CFM NOMINAL
7-ON 8-OFF HIGH 800 CFM SWITCH SETTINGS DELAY AIRFLOW
7-OFF 8-ON HIGH 800 CFM 5-OFF 6-OFF NONE 100%
7-ON 8-ON HIGH 800 CFM 5-ON 6-OFF 45 SEC 100%
5-OFF 6-ON 90 SEC 50%
5-ON 6-ON ** 50-100%
4TCY4030 AIRFLOW WITH AUXILIARY HEAT (CFM)
** This ENHANCED MODE selection provides a
SWITCH SETTINGS SELECTION NOMINAL AIRFLOW ramping up and ramping down of the indoor blower
7-OFF 8-OFF LOW 1050 CFM speed to provide improved comfort, quietness, and
7-ON 8-OFF HIGH 1200 CFM potential energy savings. The Graph below shows
7-OFF 8-ON HIGH 1200 CFM the ramping process
7-ON 8-ON HIGH 1200 CFM 100% if necessary

4TCY4036 AIRFLOW WITH AUXILIARY HEAT (CFM) 80%

FAN OPERATION (CFM)


SWITCH SETTINGS SELECTION NOMINAL AIRFLOW Dehumidify

7-OFF 8-OFF LOW 1050 CFM 50% 50%

7-ON 8-OFF HIGH 1200 CFM


7-OFF 8-ON HIGH 1200 CFM Fast Coil Cooling
Efficiency
7-ON 8-ON HIGH 1200 CFM OFF OFF

as required
4TCY4042 AIRFLOW WITH AUXILIARY HEAT (CFM) 1 7.5 3
minute minutes minutes
SWITCH SETTINGS SELECTION NOMINAL AIRFLOW COMPRESSOR OPERATION ON OFF
7-OFF 8-OFF LOW 1400 CFM
7-ON 8-OFF HIGH 1600 CFM
7-OFF 8-ON HIGH 1600 CFM
7-ON 8-ON HIGH 1600 CFM

4TCY4048 AIRFLOW WITH AUXILIARY HEAT (CFM)

SWITCH SETTINGS SELECTION NOMINAL AIRFLOW


7-OFF 8-OFF LOW 1400 CFM
7-ON 8-OFF HIGH 1600 CFM
7-OFF 8-ON HIGH 1600 CFM
7-ON 8-ON HIGH 1600 CFM

4TCY4060 AIRFLOW WITH AUXILIARY HEAT (CFM)

Switch Setting Selection Normal Airflow


7-OFF 8-OFF LOW 1750 CFM
7-ON 8-OFF HIGH 2000 CFM
7-OFF 8-ON HIGH 2000 CFM
7-ON 8-ON HIGH 2000 CFM

15
Typical Wiring

16
Typical Wiring

17
Optional Equipment
BAYCURB050A FULL PERIMETER ROOF MOUNTING CURB FOR *****024-036

17 7/8

46 3/8
3

3 5/8

19 1/2 14”

2 3/16

19 1/2
15

38 7/8
14
The drawings on this page are prepared by
1 1/2 the manufacturer in order to provide detail
regarding job layout only. These drawings
are not intended to be used as a basis to
construct, build or modify the items de-
picted in the drawings. The manufacturer is
not responsible for the unauthorized use of
these drawings and expressly disclaims any
liability for damages resulting from such
unauthorized use.

43 3/8
35 7/8

18
Optional Equipment
BAYCURB051A Full Perimeter Roof Mounting Curb for *****042-060

15 7/8

56 1/8
3

1 1/2
10 7/8
19 1/2
20 4 3/4
19 1/2
41 7/8

14

The drawings on this page are prepared by


the manufacturer in order to provide detail
regarding job layout only. These drawings
are not intended to be used as a basis to
construct, build or modify the items de-
picted in the drawings. The manufacturer is
not responsible for the unauthorized use of
these drawings and expressly disclaims any
liability for damages resulting from such
unauthorized use.

38 7/8 53 1/8

19
Optional Equipment
BAYECON101,102A Down Discharge Economizer and Rain Hood
(Mounts Over Horizontal Return Air Opening)

HVAC Unit

Economizer
rain hood
Economizer Unit Application Models A
4TC*,WC*,YC*,DC*
Outside air BAYECON101A 20.125"
dampers *018-036
Return
air damp- Required
4TC*,WC*,YC*, DC*
ers filter kit, order
BAYECON102A 24.375"
separately *042-060
Mist elimi-
nator

Relief
damper Return
Roofcurb Duct

BAYECON200,201A Horizontal Economizer and Rain Hood

The drawings on this page are


prepared by the manufacturer
in order to provide detail re-
garding job layout only. These
drawings are not intended to
be used as a basis to con-
struct, build or modify the
items depicted in the draw-
ings. The manufacturer is not
responsible for the unauthor- Economizer A
ized use of these drawings
and expressly disclaims any
liability for damages resulting
from such unauthorized use. B
D
C
Gaskets (2)

Duct E Rain Hood

Mixed Air Sensor

Economizer A B C D E F

BAYECON200AA 22" 20" 16-7/8" 15-11/16" 11-11/16" 15"

BAYECON201AA 26" 22-21/32" 19" 17-11/16" 14-11/16" 21-3/8"

20
Optional Equipment
BAYOSAH001,002A, 25% Outside Air Damper
(Replaces Filter/Coil Access Panel)

The drawings on this page are prepared by A


the manufacturer in order to provide detail
regarding job layout only. These drawings
are not intended to be used as a basis to
construct, build or modify the items de-
FULLY
picted in the drawings. The manufacturer is OPEN
not responsible for the unauthorized use of
these drawings and expressly disclaims any 2/3
D C
liability for damages resulting from such 1/3
unauthorized use.

FULLY
B CLOSED

Manual Fresh Air Unit Application


A B C D
Model Models
4YC,WC3018-036
4TC*3018-036,
BAYOSAH001 22 7/16"" 20 11/16"" 12 3/8"" 9 3/16""
4W/T/Y/DCY4024-036,
4W/Y/DCZ6036
4YC,WC3042-060,
4TC*3042-060,
BAYOSAH002 25 3/16"" 20 11/16"" 12 3/8"" 9 3/16""
4W/T/Y/DCY4042-060,
4W/Y/DCZ6048-060

BAYDMPR101,102A, 25% Motorized Outside Air Damper


(Mounts Over Horizontal Return AIr Opening)

B
C

Unit Application Models A B C D E

4YC,WC3018-036
4TC*3018-036,
BAYDMPR101A 15 13/16"" 11 13/16"" 10 1/4"" 11 1/2"" 12 1/4""
4W/T/Y/DCY4024-036,
4W/Y/DCZ6036
4YC,WC3042-060,
4TC*3042-060,
BAYDMPR102A 18 3/16"" 15 1/8"" 10 1/4"" 11 1/2"" 12 1/4""
4W/T/Y/DCY4042-060,
4W/Y/DCZ6048-060

21
Optional Equipment
BAYFLTR101, 201B, 1" - 2" Filter Rack
(Mounts in Filter/Coil Section)

Filter

BAYACCDOR1A & BAYACCDOR2A Hinged Filter Access Door


Replaces Filter/Coil Access Panel

The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not
intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is not responsible for the
unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use.

22
Dimensional Data and Weights

NOTE: The view


labeled “Bottom Side”
represents the Base
as viewed looking up
from underneath the
unit.
4TCY4024 through 4TCY4036 (1 of 3)

23
Dimensional Data and Weights

4TCY4024 through 4TCY4036 (2 of 3)

24
Dimensional Data and Weights

4TCY4024 through 4TCY4036 (3 of 3)

25
Dimensional Data and Weights

NOTE: The view


labeled “Bottom Side”
represents the Base
as viewed looking up
from underneath the
unit. 4TCY4042 through 4TCY4060 (1 of 3)

26
Dimensional Data and Weight

4TCY4042 through 4TCY4060 (2 of 3)

27
Dimensional Data and Weight

4TCY4042 through 4TCY4060 (3 of 3)

28
Mechanical Specifications
General Condenser Coil Single Source Power Entry
The units shall be horizontal airflow as The Spine Fin™condenser coil shall be This accessory, when used with electric
shipped and convertible to downflow. All continuously wrapped, corrosion resis- heat accessory, shall allow single source
units shall be factory assembled, piped, in- tant all aluminum with minimum brazed power connection to unit and heater com-
ternally wired and fully charged with R‑22. joints. This coil is 3/8 inch O.D. seamless bination. Single source power entry kits
All units shall be factory run tested to check aluminum tubing glued to a continuous shall have specific matching heater(s). Kit
cooling operation, fan and blower rotation aluminum fin. Coils are lab tested to shall include high voltage terminal blocks,
and control sequence. Units shall be designed withstand 2,000 pounds of pressure per fuse blocks and fuses, cut‑to‑length in-
to operate at ambient temperatures between terconnecting wiring, and junction box (if
square inch. The outdoor coil provides
55°F and 115°F in cooling as manufactured. required) to provide power sources with
low airflow resistance and efficient heat fuse protection as required for both the
Cooling performance shall be rated in accor-
transfer. The coil is protected on all four unit and accessory heater. Kit components
dance with A.H.R.I. standards.
sides by louvered panels. shall install within the heater cabinet in the
Unit Casing Indoor Air Fan heater access section. Single source branch
All panels shall be heavy gauge steel, gas- Direct-drive, forward-curved, centrifugal power circuit shall be protected and wired
keted and insulated. Foil-faced fiber insula- wheel in a Composite Vortica® Blower in accordance with local codes.
tion shall be in the heater section. Foil-faced housing. Motor shall have thermal overload
fiber insulation shall be in the evaporator protection and permanently lubricated Fully Modulating Economizer
section. Base pan shall be heavy gauge steel. motor bearings. Motor/blower assembly This accessory shall be field installed and be
WEATHERGUARD™exteriorcorrosionresistant isolated from unit with rubber mounts. composed of the following items: 0‑100% fresh
screws shall be used for added resistance to air damper, damper drive motor, fixed dry bulb
rust and corrosion. Outdoor Fan enthalpy control, and low voltage pigtails for
One direct‑drive, statically and dynami- electrical connections. Solid state enthalpy
Compressor cally balanced propeller fan shall be used in or differential enthalpy control is optional.
The compressor shall be a hermetically a draw­through configuration. Permanently Economizer operations shall be controlled by
sealed, high efficiency Climatuff® com- lubricated weather proof motor shall have the preset position of the enthalpy control.
pressor. Internal overcurrent and over built‑in thermal overload protection. A barometic relief damper shall be standard
temperature protection, internal pressure with the downflow economizer and provide a
relief shall be standard. Other features System Controls pressure operated damper that shall be gravity
include, centrifugal oil pump and low vibra- System controls include condenser fan, closing and prohibit entrance of outside air on
tion and noise. evaporator fan and compressor contactors. equipment “off” cycle.

Refrigeration System Accessories Manual Outside Air Dampers


All units shall have refrigerant control. Service Roof Curb Rain hood and screen shall be field installed.
pressure tap ports, and a refrigerant line filter The roof curb shall be designed to mate with Suitable for up to 25% outside air.
shall be standard. the unit and provide support and complete
weathertight installation when properly in- Start Kit
Evaporator Coil stalled. Adhesive back polyurethane sealing Extra compressor starting capacity for single
Internally enhanced 3/8‑inch OD seamless strips shall be provided to ensure an airtight phase equipment.
copper tubing me­chani­cally bonded to alu- seal between supply and return openings of
the curb and unit.The roof curb design allows ControlOptionsStandardIndoorThermostats
minum fins, factory pressure and leak tested
field fabricated ductwork to be connected Two stage heating/cooling or one stage heat-
at 250 to 300 psig. All units have a TXV to ing/cooling thermostats shall be available in
control refrigerant flow. directly to the curb. Curb ships knocked down
for field assembly, and includes factory‑in- either manual or automatic changeover.
stalled wood nailer strips.
Programmable Electronic Night Setback
Electric Heaters Thermostat
Each heater assembly shall include power Programmable electronic thermostat shall
supply fusing if over 48 amps, automatic provide heating setback and cooling setup
resetting limit switches and heat limiters for with 7‑day, programming capability. 1 H/1 C
thermal protection. Heaters shall be provided or 2H/2C models available.
with polarized plugs for quick connection to
unit low voltage wiring.


Trane Trane has a policy of continuous product and product data improvement and it reserves the right to change design
6200 Troup Highway and specifications without notice.
Tyler, TX 75707-9010

29