CQM SMC
CQM SMC
CQM SMC
CQM Series
ø12, ø16, ø20, ø25, ø32, ø40, ø50, ø63, ø80, ø100
Lateral load
resisting
2 to 4 times
∗ Compared to compact
cylinder the CQ series
Non-rotating
accuracy
± 0.2° or less
Refer to page 1008
CUJ
CU
External dimensions Slide bearing CQS
Load can be directly JCQ
mounted.
CQ2
RQ
Mounting dimensions
compatible with CQM
the CQS, CQ2 series.
CQ2series CQU
Auto switch is mountable/removable even when
the plate is retracted.
MU
Series Variations
12, 16
20, 25 Rubber D-
CQM bumper
32, 40 -X
50, 63, 80, 100 Technical
Data
1005
Compact Cylinder: Guide Rod Type
CQM Series
ø12, ø16, ø20, ø25, ø32, ø40, ø50, ø63, ø80, ø100
How to Order
CQM B 20 15
With auto switch CDQM B 20 15 M9BW
With auto switch Number of auto switches
(Built-in magnet) Nil 2 pcs.
S 1 pc.
Mounting bracket
n “n” pcs.
B Through-hole (Standard)
A Both ends tapped (ø32 to ø100) Auto switch type
Note 1) Cylinder bodies of ø12 to ø25 are
Nil Without auto switch
common for both B (through hole) and
A (both ends tapped) types. Symbol to ∗ Refer to the table below for the
order is unified to “B” for those sizes. applicable auto switch model.
Note 2) Cylinder mounting bolts are not
included. Order them separately Cylinder stroke (mm)
referring to Mounting Bolts for CQM on
pages 1010 and 1011.
Refer to page 1007 for standard and
Note 3) Contact SMC for the other mounting intermediate strokes.
types.
Thread type
Bore size Nil
M thread ø12 to ø25
12 12 mm 40 40 mm Rc
16 16 mm 50 50 mm TN NPT ø32 to ø100 Built-in Magnet Cylinder Model
20 20 mm 63 63 mm TF G If a built-in magnet cylinder without an
25 25 mm 80 80 mm Note) M thread to be used for without auto switch is required, there is no need
32 32 mm 100 100 mm auto switch type of ø32, 5 stroke to enter the symbol for the auto switch.
exceptionally. There is no need to (Example) CDQMB32-10
enter the symbol when ordering.
Applicable Auto Switches/Refer to pages 1575 to 1701 for further information on auto switches.
Load voltage Auto switch model Lead wire length (m)
Indicator light
2-wire 12 V —
Connector — J79C —
3-wire (NPN) 5 V, M9NWV M9NW
Diagnostic indication IC circuit
(2-color indicator)
3-wire (PNP) 12 V M9PWV M9PW Relay,
Yes 24 V —
2-wire 12 V M9BWV M9BW — PLC
3-wire (NPN) 5 V, M9NAV∗1 M9NA∗1
Water resistance Grommet IC circuit
(2-color indicator) 3-wire (PNP) 12 V M9PAV∗1 M9PA∗1
2-wire 12 V M9BAV∗1 M9BA∗1 —
With diagnostic output (2-color indicator) 4-wire 5 V,12 V — — F79F IC circuit
Magnetic field resistant (2-color indicator) 2-wire (Non-polar) — — — P4DW∗∗ —
3-wire
(NPN equiv.) —
5V — A96V A96 IC circuit —
Reed auto switch
Yes
Grommet — 200 V — A72 — A72H
—
— 12 V 100 V A93V∗2 A93
No 5 V,12 V 100 V or less A90V A90 IC circuit Relay,
2-wire
Yes 24 V 12 V — — A73C — — PLC
Connector
No 5 V,12 V 24 V or less — A80C — IC circuit
With diagnostic output (2-color indicator) Grommet Yes — — — A79W — —
∗1 Water resistant type auto switches can be mounted on the above models, but in such case SMC cannot guarantee water resistance.
Consult with SMC regarding water resistant types with the above model numbers.
∗2 1 m type lead wire is only applicable to D-A93.
∗ Lead wire length symbols: 0.5 m·········· Nil (Example) M9NW ∗ Solid state auto switches marked with a "" are produced upon receipt of order.
1 m·········· M (Example) M9NWM ∗∗ D-P4DWL type is compatible with bore sizes ø40 to ø100.
3 m·········· L (Example) M9NWL ∗ Only D-P4DW type is assembled when shipped.
5 m·········· Z (Example) M9NWZ
None·········· N (Example) J79CN
∗ Besides the models in the above catalog, there are some other auto switches that are applicable. For more information, refer to page 1017.
∗ Refer to pages 1648 and 1649 for the details of auto switches with a pre-wired connector.
∗ When mounting D-A9(V)/M9(V)/M9W(V)/M9A(V) types on a side other than the port side with ø32 to ø50 cylinders, order auto switch mounting brackets separately. Refer
to page 1017 for details.
1006
Compact Cylinder: Guide Rod Type CQM Series
Specifications
Bore size (mm) 12 16 20 25 32 40 50 63 80 100
Model Pneumatic (non-lube) type
Action Double acting, Single rod
Fluid Air
Proof pressure 1.5 MPa
Maximum operating pressure 1.0 MPa
Minimum operating pressure 0.12 MPa 0.1 MPa
Ambient and fluid Without auto switch: –10°C to 70°C (No freezing)
temperature With auto switch: –10°C to 60°C (No freezing)
Cushion Rubber bumper on both ends
+1.0 mm∗
Stroke length tolerance
0
Mounting Through-holes
Piston speed 50 to 500 mm/s 50 to 300 mm/s
Caution ∗ Stroke length tolerance does not include the amount of dumper change.
Unit: N.m
100.0 ø100
Stroke Eccentric distance
ø80
ø63
ø50
Load mass (kg)
10.0
ø4
0
ø100 ø3
100 2
Plate allowable lateral load (N)
ø2
ø80 5
ø2
1.0 0
ø63 ø1
6
ø1
2
ø50
0.1
ø40 50 100 200 300 500
ø32 Maximum piston speed (mm/s)
10
ø20, ø25
ø12, ø16
1008
Compact Cylinder: Guide Rod Type CQM Series
Construction
ø12 to ø25
With auto switch
o t !5 !1 w !7 !2 q r !6 e !3 (Built-in magnet) !4
!0 u y
ø32 to ø100
With auto switch
o t !5 !1 w !7 !2 r q !6 e !3 (Built-in magnet) !4
CUJ
CU
!0 u y
CQS
JCQ
ø50 to ø100
Component Parts CQ2
No. Description Material Note
i 1 Cylinder tube Aluminum alloy Hard anodized RQ
Aluminum alloy ø12 to ø40 Anodized
2 Collar
Aluminum alloy casted ø50 to ø100 Chromated, Coated CQM
3 Piston Aluminum alloy
Stainless steel ø12 to ø25 CQU
4 Piston rod
Carbon steel ø32 to ø100 Hard chrome plated
5 Plate Aluminum alloy Anodized MU
6 Guide rod Stainless steel
7 Bushing Bearing alloy
8 Bushing Bearing alloy ø50 to ø100
9 Hexagon socket head cap screw Carbon steel Zmc chromated
10 Hexagon socket head cap screw Carbon steel Zmc chromated
11 Retaining ring Carbon tool steel Phosphate coated
12 Bumper A Urethan
13 Bumper B Urethan D-
14 Magnet —
15 Rod seal NBR -X
16 Piston seal NBR Technical
17 Gasket NBR Data
1009
CQM Series
Mounting Bolt
Cylinder model C D Mounting bolt part no. Cylinder model C D Mounting bolt part no. C
Cylinder model D Mounting bolt part no.
CQMB12- 5 25 CQ-M3 x 25L CQMB32- 5 30 CQ-M5 x 30L CQMB63- 10 50 CQ-M8 x 50L
-10 30 x 30L - 10 35 x 35L - 15 55 x 55L
-15 35 x 35L - 15 40 x 40L - 20 60 x 60L
6.5
-20 40 x 40L - 20 45 x 45L - 25 65 x 65L
-25 45 x 45L - 25 50 x 50L - 30 70 x 70L
-30 50 x 50L - 30 55 x 55L - 35 14.5 75 x 75L
9
CQMB16- 5 25 CQ-M3 x 25L - 35 60 x 60L - 40 80 x 80L
-10 30 x 30L - 40 65 x 65L - 45 85 x 85L
-15 35 x 35L - 45 70 x 70L - 50 90 x 90L
6.5
-20 40 x 40L - 50 75 x 75L - 75 125 x 125L
-25 45 x 45L - 75 110 x 110L -100 150 x 150L
-30 50 x 50L -100 135 x 135L CQMB80- 10 55 CQ-M10 x 55L
CQMB20- 5 25 CQ-M5 x 25L CQMB40- 5 35 CQ-M5 x 35L - 15 60 x 60L
-10 30 x 30L - 10 40 x 40L - 20 65 x 65L
-15 35 x 35L - 15 45 x 45L - 25 70 x 70L
-20 40 x 40L - 20 50 x 50L - 30 75 x 75L
-25 45 x 45L - 25 55 x 55L - 35 15 80 x 80L
6.5
-30 50 x 50L - 30 60 x 60L - 40 85 x 85L
7.5
-35 55 x 55L - 35 65 x 65L - 45 90 x 90L
-40 60 x 60L - 40 70 x 70L - 50 95 x 95L
-45 65 x 65L - 45 75 x 75L - 75 130 x 130L
-50 70 x 70L - 50 80 x 80L -100 155 x 155L
CQMB25- 5 30 CQ-M5 x 30L - 75 115 x 115L CQMB100- 10 65 CQ-M10 x 65L
- 10 35 x 35L -100 140 x 140L - 15 70 x 70L
- 15 40 x 40L CQMB50- 10 45 CQ-M6 x 45L - 20 75 x 75L
- 20 45 x 45L - 15 50 x 50L - 25 80 x 80L
- 25 50 x 50L - 20 55 x 55L - 30 85 x 85L
8.5
- 30 55 x 55L - 25 60 x 60L - 35 15.5 90 x 90L
- 35 60 x 60L - 30 65 x 65L - 40 95 x 95L
- 40 65 x 65L - 35 12.5 70 x 70L - 45 100 x 100L
- 45 70 x 70L - 40 75 x 75L - 50 105 x 105L
- 50 75 x 75L - 45 80 x 80L - 75 140 x 140L
- 50 85 x 85L -100 165 x 165L
- 75 120 x 120L
-100 145 x 145L
1010
Compact Cylinder: Guide Rod Type CQM Series
Cylinder model C D Mounting bolt part no. Cylinder model C D Mounting bolt part no. Cylinder model C D Mounting bolt part no.
CDQMB12- 5 30 CQ-M3 x 30L CDQMB32- 5 40 CQ-M5 x 40L CDQMB63- 10 60 CQ-M8 x 60L
-10 35 x 35L - 10 45 x 45L - 15 65 x 65L
-15 40 x 40L - 15 50 x 50L - 20 70 x 70L
6.5
-20 45 x 45L - 20 55 x 55L - 25 75 x 75L
-25 50 x 50L - 25 60 x 60L - 30 80 x 80L
-30 55 x 55L - 30 65 x 65L - 35 14.5 85 x 85L
9
CDQMB16- 5 30 CQ-M3 x 30L - 35 70 x 70L - 40 90 x 90L
-10 35 x 35L - 40 75 x 75L - 45 95 x 95L
-15 40 x 40L - 45 80 x 80L - 50 100 x 100L
6.5
-20 45 x 45L - 50 85 x 85L - 75 125 x 125L
-25 50 x 50L - 75 110 x 110L -100 150 x 150L
-30 55 x 55L -100 135 x 135L CDQMB80- 10 65 CQ-M10 x 65L
CDQMB20- 5 35 CQ-M5 x 35L CDQMB40- 5 45 CQ-M5 x 45L - 15 70 x 70L
-10 40 x 40L - 10 50 x 50L - 20 75 x 75L
-15 45 x 45L - 15 55 x 55L - 25 80 x 80L
-20 50 x 50L - 20 60 x 60L - 30 85 x 85L
-25 55 x 55L - 25 65 x 65L - 35 15 90 x 90L
6.5
-30 60 x 60L - 30 70 x 70L - 40 95 x 95L
7.5
-35 65 x 65L - 35 75 x 75L - 45 100 x 100L
-40 70 x 70L - 40 80 x 80L - 50 105 x 105L
-45 75 x 75L - 45 85 x 85L - 75 130 x 130L
-50 80 x 80L - 50 90 x 90L -100 155 x 155L
CDQMB25- 5 40 CQ-M5 x 40L - 75 115 x 115L CDQMB100- 10 75 CQ-M10 x 75L
-10 45 x 45L -100 140 x 140L - 15 80 x 80L
-15 50 x 50L CDQMB50- 10 55 CQ-M6 x 55L - 20 85 x 85L
-20 55 x 55L - 15 60 x 60L - 25 90 x 90L
-25 60 x 60L - 20 65 x 65L - 30 95 x 95L
8.5
-30 65 x 65L - 25 70 x 70L - 35 15.5 100 x 100L
-35 70 x 70L - 30 75 x 75L - 40 105 x 105L
-40 75 x 75L - 35 12.5 80 x 80L - 45 110 x 110L
-45 80 x 80L - 40 85 x 85L - 50 115 x 115L
-50 85 x 85L - 45 90 x 90L - 75 140 x 140L
- 50 95 x 95L -100 165 x 165L CUJ
- 75 120 x 120L
-100 145 x 145L CU
CQS
JCQ
CQ2
RQ
CQM
CQU
MU
D-
-X
Technical
Data
1011
CQM Series
Dimensions
ø12 to ø25
V
ø12 V ø16
2 x 2 x øOB counterbore with depth RB 2 x M5 x 0.8
Auto switch
2 x øHB through
2 x HA through Q F
A
øIB
K
øIA
2 x øN through
T
EB
EA
M
K
(KB)
A
2 x 2 x OA
V
Note)
M Flat washer L 2 x 2 x RA (RB)
4 pcs
EB W B + Stroke
EA A + Stroke
ø20, 25
(mm)
Bore size Stroke range Without auto switch With auto switch
(mm) (mm) EA EB F HA OA HB IA IB
A B A B
12 5 to 30 26.5 17 31.5 22 25 24 5 M3 x 0.5 M4 x 0.7 3 +0.2
0 32 31.5
16 5 to 30 26.5 17 31.5 22 29 28 5 M3 x 0.5 M4 x 0.7 3 +0.2
0 38 37
20 5 to 50 32 19.5 42 29.5 36 34 5.5 M4 x 0.7 M6 x 1.0 4 +0.2
0 47 45.5
25 5 to 50 35.5 22.5 45.5 32.5 40 38 5.5 M5 x 0.8 M6 x 1.0 5 +0.2
0 52 50.5
Bore size
(mm) KA KB L M N OB Q RA RB T V W
12 10 ± 0.1 7.1 3.5 15.5 3.5 6.5 7.5 7 4 0.5 14.9 6
16 14 ± 0.1 9.9 3.5 20 3.5 6.5 7.5 7 4 0.5 20 6
20 17 ± 0.1 12 4.5 25.5 5.4 9 9 10 7 1 26 8
25 22 ± 0.1 15.6 5 28 5.4 9 11 10 7 1 30 8
Note) For the following bore/stroke sizes, the through-hole is threaded.
Standard without auto switch: ø12 and ø16; 5 stroke, ø20; 5 to 15 stroke, ø25; 5 and 10 stroke,
Built-in magnet with auto switch: ø20; 5 stroke
1012
Compact Cylinder: Guide Rod Type CQM Series
Dimensions
ø32 to ø50
2 x HA through
2 x øHB through 2xP Auto switch
V
2 x øN through Q F
A
K
øIA
EC
EB
EA
M
Z
(KB)
K
A
M
EC W L B + Stroke
EB A + Stroke
EA J
2 x 2 x RA 2 x 2 x OA
D-
-X
Technical
Data
1013
CQM Series
Dimensions
ø63 to ø100
øIA
EC
EB
EA
M
Z
(KB) W L B + Stroke
M A + Stroke
K
A
EC
EB
EA J
2 x 2 x RA
2 x 2 x OA
(mm)
Without auto switch With auto switch
Bore size Stroke range EA EB EC F HA HB IA IB J KA KB L M
(mm) (mm) A B A B
10 to 50 56 36 +0.2
63 66 46 77 74 59.6 10.5 M6 x 1 6 0 103 100 7 50 ± 0.2 35.4 8 60
75, 100 66 46
10 to 50 67.5 43.5 +0.2
80 77.5 53.5 98 95 79.5 12.5 M8 x 1.25 8 0 132 129 6 65 ± 0.2 46 10 77
75, 100 77.5 53.5
10 to 50 79 53 +0.2
100 89 63 117 114 99 13 M10 x 1.5 10 0 156 153 6.5 80 ± 0.2 56.6 10 94
75, 100 89 63
Bore size P
N OA OB Q RA RB V W Z
(mm) — TN TF
63 9 M10 x 1.5 14 Rc 1/4 NPT 1/4 G 1/4 15 18 10.5 69 12 19
80 11 M12 x 1.75 17.5 Rc 3/8 NPT 3/8 G 3/8 16 22 13.5 89 14 26
100 11 M12 x 1.75 17.5 Rc 3/8 NPT 3/8 G 3/8 23 22 13.5 113 16 26
1014
CQM Series
Auto Switch Mounting 1
Minimum Auto Switch Mounting Stroke
(mm)
Auto switch D-A7 D-F7W
Bore size
No. model D-M9WV D-M9W D-F7V D-A8 D-F7WV D-F7 D-A7H D-J79W ∗
of auto D-M9V D-A9V D-A9 D-M9 D-A79W D-F7BA D-P4DW
(mm)
switch D-M9AV D-M9A D-J79C D-A73C D-F7BAV D-J79 D-A80H D-F7NT
mounted D-A80C D-F79F
12, 16, 1 pc. 5 5 10(5) 10 15(5) 15(10) — — — — — — — —
20, 25 2 pcs. 5 10 10 10 15(5) 15(10) — — — — — — — —
32, 40, 50, 1 pc. 5 5 10(5) 10 10(5) 15(10) 5 5 10 15(5) 15(5) 15 20(10) 15
63, 80, 100 2 pcs. 5 10 10 15 10(5) 15 5 10 15 15(5) 15(10) 20 20(15) 15
∗ D-P4DWL type is compatible with bore sizes ø40 to ø100.
Note) The dimension stated in ( ) shows the minimum mountable stroke when the auto switch does not project from the end face of the cylinder body and the lead wire bending
space is not hindered. (Refer to the figure below.)
The auto switch and its mounting bracket are ordered separately. (Bore sizes ø12 to ø25 do not need any auto switch mounting bracket.)
Proper Auto Switch Mounting Position (Detection at stroke end) and Its Mounting Height
D-A9 D-M9W D-A9V
D-M9 D-M9A D-M9V
ø12 A B W
D-M9WV Approx. Hs
D-M9AV
ø16, 20, 25
A B A W Approx. Hs
CUJ
ø32 to ø100
CU
A B A W Approx. Hs
CQS
JCQ
CQ2
RQ
Auto Switch Mounting
Proper Auto Switch Mounting Positions (mm) Height (mm)
CQM
Auto switch D-M9 Auto switch
model D-A9 D-M9V D-M9A model
D-A9V
D-M9V
D-M9WV
CQU
D-A9V D-M9W D-M9AV
D-M9WV D-M9AV
Bore
size A B W A B W A B W
Bore
size Hs Hs
MU
12 1.5 0.5 1.5 (4) 5.5 4.5 5.5 5.5 4.5 7.5 12 17 19
16 2 0 2 (4.5) 6 4 6 6 4 8 16 19 21
20 6 3.5 –1.5 (1) 10 7.5 2.5 10 7.5 4.5 20 22.5 24
25 7 5.5 –3.5 (–1) 11 9.5 0.5 11 9.5 2.5 25 24.5 26
32 8 5 –3 (–0.5) 12 9 1 12 9 3 32 27 29
40 12 7.5 –5.5 (–3) 16 11.5 –1.5 16 11.5 0.5 40 30.5 32.5
50 10 10.5 –8.5 (–6) 14 14.5 –4.5 14 14.5 –2.5 50 36.5 42
63 12.5 13.5 –11.5 (–9) 16.5 17.5 –7.5 16.5 17.5 –5.5 63 40 42
80 15.5 18 –16 (–13.5) 19.5 22 –12 19.5 22 –10 80 50 52
D-
100 20 23 –21 (–18.5) 24 27 –17 24 27 –15 100 60 62
Note 1) ( ): For D-A93 type -X
Note 2) W is used for mounting D-A9, D-M9, D-M9W and D-M9A types.
Note 3) Negative figures for W in the table indicate that an auto switch is mounted inward from the edge of the cylinder body. Technical
Note 4) Adjust the auto switch after confirming the operating condition in the actual setting. Data
1015
CQM Series
Auto Switch Mounting 2
Proper Auto Switch Mounting Position (Detection at stroke end) and Its Mounting Height
D-A7 D-F7V D-A7H D-F7 D-P4DW
D-A80 D-J79C D-A80H D-J79
D-A73C D-F7WV D-F7W
D-A80C D-F7BAV D-J79W
D-A79W D-F7BA
D-F79F ø40 to ø100
ø32 to ø100 D-F7NT A B Approx. Hs
A B Approx. Hs
Operating Range
(mm)
Bore size
Auto switch model
12 16 20 25 32 40 50 63 80 100
D-A9/A9V 6 7.5 10 10 9.5 9.5 9.5 11.5 9 11.5
D-M9/M9V
D-M9W/M9WV 3 4 5.5 5.5 6 6 7 7.5 8 8.5
D-M9A/M9AV
D-A7/A80 — — — — 12 11 10 12 12 13
D-A79W — — — — 13 14 14 16 15 17
D-F7/F7V
D-J79/J79C
D-F7W/F7WV — — — — 6 6 6 6.5 6.5 7
D-J79W
D-F7BA/F7BAV
D-F7NT/F79F
D-P4DW — — — — — 5 5 5 5 5.5
∗ Since the operating range is provided as a guideline including hysteresis, it cannot be guaranteed (assuming
approximately ±30% dispersion). It may vary substantially depending on an ambient environment.
∗ Auto switch mounting brackets BQ2-012 are not used for sizes over ø32 of D-A9(V)/M9(V)/M9W(V)/M9A(V) types.
The above values indicate the operating range when mounted with the current auto switch installation groove.
1016
Auto Switch Mounting CQM Series
C A C A C A C A
B B B
B
Auto switch mounting surface Auto switch mounting surface Auto switch mounting surface Auto switch mounting surface
Auto switch
model A, B, C sides Port, A, B, C sides Port side A, B, C sides Port, A, B, C sides
BQ-2
BQ2-012
2 kinds of auto switch mounting
D-A9 brackets are used as a set.
Set screw
D-A9V (not used)
D-M9 Auto switch
Auto switch mounting Auto switch mounting Auto switch mounting
D-M9V mounting
bracket not required. bracket not required. bracket not required.
D-M9W bracket not
D-M9WV required.
D-M9A
D-M9AV
Note 1) For each cylinder series, when a compact auto switch is mounted on the three sides (A, B and C above) other than the port side of bore sizes ø32 to ø50, the auto switch
mounting brackets above are required. Order them separately from cylinders.
Order example
CDQMB32-50-M9BW……1
BQ-2……2 pcs.
BQ2-012……2 pcs.
Note 2) When shipping cylinders, auto switch mounting brackets and auto switches are shipped together.
The number of the surfaces and grooves where the auto switch can be mounted, by auto switch type, are shown in the table below.
Auto switch type D-A9(V), M9(V), M9W(V), M9A(V) D-A7, A8, F7, J7
Bore size A B C D A B C D
(Mounting (Mounting (Mounting (Mounting (Mounting (Mounting (Mounting (Mounting
Port aperture (mm) groove no.) groove no.) groove no.) groove no.) groove no.) groove no.) groove no.) groove no.)
A
12 (1) (1) (1)
16 (2) (2) (2)
D B 20 (2) (2) (2) (2)
View from 25
piston rod end (2) (2) (2) (2)
C 32 (2)
40 (2)
50 (2)
63 (2) (2) (2) (2)
80 (2) (2) (2) (2)
100 (2) (2) (2) (2)
1018
CQM Series
Specific Product Precautions
Be sure to read this before handling the products.
Refer to back page 50 for Safety Instructions and pages 3 to 12 for Actuator
and Auto Switch Precautions.
Mounting Others
Warning Caution
1. Do not put hands or fingers between the plate 1. This product should not be used as a stopper.
and cylinder tubing. 2. Do not disassemble and modify the product.
Never put hands or fingers in the gap between the plate and
cylinder tubing when the piston rods are retracted. Due to the
3. For example, in a pressing application, the
heavy power output of the cylinder, failure to comply with this cylinder thrust is directly applied to the plate,
directive may result in trapping and subsequent injury to the therefore, make sure that the pressing force is
human body. applied to the plate directly on the extended
axial line of a rod. (Below figures.)
Caution
1. Do not scratch or dent the sliding parts of the
piston rod and guide rods.
Damage to seals may cause air leakage or faulty operation.
2. Mounting of work piece
When screwing a bolt onto the threaded portion of the plate
surface, be certain that the guide rods are fully extended to the
end.
Also, be careful that the tightening torque is not applied to the
CUJ
guide rods.
3. Make sure that the cylinder mounting sur-
CU
face has a flatness of 0.02 mm or less. CQS
When mounting the cylinder body or workpieces on the plate,
improper flatness of the mounting surface may cause
malfunctions. JCQ
When the flatness of a workpiece is not sufficient, attaching a
shim such as a flat washer, etc., at the place of a mounting CQ2
bolt between the workpiece and the plate may reduce the
affect on the operation. RQ
CQM
CQU
MU
D-
-X
Technical
Data
1019