360°dcLoung

warum.Future

MTU ONSITE ENERGY


Mission Critical Power
Data Center
13.-14.12.2016
Hamburg, Germany

© MTU Onsite Energy GmbH


All rights
Alle Rechte
reserved
vorbehalten
01 ROLLS-ROYCE
Vision

A pre-eminent engineering
company, focused on world-class
power and propulsion systems.

Trusted to deliver excellence.

Page 2 MTU Onsite Energy for Client / Date


© MTU Onsite Energy GmbH / All rights reserved / Confidential
01 ROLLS-ROYCE
Who we are

RR Revenue 2015:
£13,4bn

Page 3 MTU Onsite Energy for Client / Date


© MTU Onsite Energy GmbH / All rights reserved / Confidential
01 Rolls-Royce Power Systems
Product overview

High Speed High Speed Medium Speed


Diesel Systems Gas Systems Gas, Diesel, HFO Systems
(>1000 rpm) (>1000 rpm) (<1000 rpm)

MTU 0080-0120 DS
MTU 1600 DS
MTU 400 GS B35:40 (Gas)
MTU 2000 DS
MTU 4000 GS B32:40 (Diesel & HFO)
MTU 4000 DS
MTU Series 956 (NPP)

Page 4 MTU Onsite Energy for Client / Date


© MTU Onsite Energy GmbH / All rights reserved / Confidential
01 Rolls-Royce Power Systems
Power Range

0 1,000 2,000 3,000 4,000 5,000 6,000 7,000 8,000 9,000 10,000
CONTINUOUS/ PRIME/

Diesel / HFO: 200kWe-10,000kWe


PEAK

Gas: 30kWe -10,000kWe


STANDARD.
BACKUP

Diesel: 30kWe - 3,300kWe

Gas: 30kWe - 400kWe


CRITICAL
MISSION

Diesel: 800 kWe - 10,000kWe

Page 5 MTU Onsite Energy for Client / Date


© MTU Onsite Energy GmbH / All rights reserved / Confidential
01 ROLLS-ROYCE POWER SYSTEMS
Mission critical stand-by

1E classified International certified


EDGs for civil EDGs for Uptime
nuclear Inst. tier IV rated
applications data centers

Page 6 MTU Onsite Energy for Client / Date


© MTU Onsite Energy GmbH / All rights reserved / Confidential
02 Data Center Solutions
Overview

MISSION CRITICAL – DATA CENTERS

Data centers need to ensure utmost Our products:


reliability 365 days a year to power
and cool the servers – with MTU 2000DS & MTU 4000 DS
uninterrupted power supply
Our power range (in kWe):

800 – 2,800

0 10,000

Key features:
 Unlimited operating hours
 Overload option available
 6 out of the top 10 online companies rely on MTU
 Compliant with “Uptime Institute” Tier III & IV
requirements
 Up to 99,99% availability

Page 7 MTU Onsite Energy for Client / Date


© MTU Onsite Energy GmbH / All rights reserved / Confidential
02 Data Center Solutions
We accompany you through the entire project

Support
Seamless Cooperation in Project Business
Planning - Sales – Development - Integration - Service

Sales Project Mgmt Service LTSA

Project RFQ Order Site Acceptance Time


Start

Page 8 MTU Onsite Energy for Client / Date


© MTU Onsite Energy GmbH / All rights reserved / Confidential
02 Data Center Solutions
Key Technology

- Modular concepts to integrate customer specific requirements in short time


- Standardized products from reliable supplier
- Use of well proven equipment
- Increase of diesel system availability
• preheated and pre-lubricated diesel engine
• redundant starting system
• automatic refill of engine oil
• Redundant controller

Page 9 MTU Onsite Energy for Client / Date


© MTU Onsite Energy GmbH / All rights reserved / Confidential
03 warum.Future
Integration of Renewables/ Energy Transition

Page 10 MTU Onsite Energy for Client / Date


© MTU Onsite Energy GmbH / All rights reserved / Confidential
03 warum.Future
Actual & future trends for stand-by systems

1. Higher flexibility in grid parallel operation (low-voltage ride-through,


frequency drops, …)
2. Lower emissions driven by different regulatory bodies (EU, country, region,
city, …)
3. Fuel diversity (gas, bi-fuel, green diesel, etc.)
4. Flexible systems for ultra-fast response over negative capacity up to
temporary base load power supply: integrated battery / heat storage
systems with integrated gas/diesel units  Flexible power response
systems:
- Uninterrupted Power Supply
- Frequency response
- Peak-shaving
- Negative power balance (“negative Regelenergie”)
- Optional: Combined Heat & Power

Page 11 MTU Onsite Energy for Client / Date


© MTU Onsite Energy GmbH / All rights reserved / Confidential
03 warum.Future
Grid Support Overview

HV-Grid

Rolls-Royce Power Systems


Others
Master
Controller

MV-Grid

Gas-/Diesel- CHP- Energy Storage Renewables


Genset Plant

Page 12 MTU Onsite Energy for Client / Date


© MTU Onsite Energy GmbH / All rights reserved / Confidential
03 warum.Future
1. Higher flexibility in grid parallel operation

BDEW-Zertifikat (German Grid Code & Basis for Europe, ROW)

-> The only one “Gas & Diesel Systems”

Page 13 MTU Onsite Energy for Client / Date


© MTU Onsite Energy GmbH / All rights reserved / Confidential
03 warum.Future
2. Lower emissions

• Engine internal measures


(injection, Miller-cycle,…)
• Alternative fuels
• Exhaust gas treatment (SCR,
particle filters, ….)
• Noise emission reductions
(through special enclosures and
exhaust gas silencers) down to
45dBA

S2000

Page 14 MTU Onsite Energy for Client / Date


© MTU Onsite Energy GmbH / All rights reserved / Confidential
03 warum.Future
3. Fuel diversity

Bio diesel of the first generation (DME / FAME) are becoming less
important. The focus is now on the second generation Paraffinic Diesel
Fuels:
 Synthetically created from feedstock like natural gas (GTL), biomass
(BTL) or coal (CTL)
 Created of vegetable oils or animal fats (HVO) through hydro-treatment
The fuels burn cleaner than conventional crude-oil based diesel fuels and
are thus able to reduce local harmful emissions such as nitrogen oxides
and particulate matter (i.e. less visible black smoke).

Shell GTL Fuel is an alternative fuel for use in diesel


engines, which can lower local emissions (e.g. particulate
matter, NOx, hydrocarbons and carbon monoxide).

Page 15 MTU Onsite Energy for Client / Date


© MTU Onsite Energy GmbH / All rights reserved / Confidential
03 warum.Future
3. Flexible systems – tri-gen

Page 16 MTU Onsite Energy for Client / Date


© MTU Onsite Energy GmbH / All rights reserved / Confidential
03 warum.Future
3. Flexible systems – micro grid

Page 17 MTU Onsite Energy for Client / Date


© MTU Onsite Energy GmbH / All rights reserved / Confidential