A-STAR TESTING & INSPECTION (S) Pte Ltd

No.05 , Soon Lee Street,Pionner Point,#3-36/37, Singapore 627607


Tel: (65)62616162 / 93829286 / fax: (65)62616163
Email: admin@astartesting.com.sg / Website: www.astartesting.com.sg

VISUAL EXAMINATION REPORT Page: 1 of 1


###
Report No : : ATI-YNEC-PQR-VI-003 Client : Yongam Engineering & Construction Pte Ltd
Date of test : : 22.01.19 Test conducted by : A-Star Technical Service (s) Pte Ltd
Acceptance Standard : : BS EN ISO 15614-1 Description : Welding procedure qualification test plate

Ground As Welded Material


Plate Pipe
Visual Weld EN 10025-4 S460M
NA Yes Length 450 mm Dia. : NA
Thk 100 mm Thk : NA Heat Treatment NA

Type Of Equipment Used During Test . (Tick box)

Ruler ü Welding gauge ü Magnifying Glass û Others û

Welding Types of imperfection


PQR no: / Welder Identification Type of Joint Result Remarks
Process
1 2 3 4 5 6 7 8 9 10 11 12
FD/S460/SV-B/003/3G/PQR-317
Single V butt
136
Selvaraju Iyappan
(FCAW-DS)
weld with û û û NA NA û NA û NA NA û û Accepted
IC.No.0 33996233 backing
(PF)

1. Crack 7. Shrinkage groove


2. Crater crack 8. Excess weld metal (Butt weld)
3. Surface pore 9. Excessive convexity (Fillet weld)
4. Lack of fusion 10. Excess penetration
5. Incomplete root penetration 11. Incomplete filled groove (Butt) / Insufficent throat (Fillet) YES: ü NO: û
6. Under cut 12. Others (Slag,poor restart,stray arc,Spatter)

……………………………………………………… ………………………………………………………………
Examiner or examining body Manufacturer
Name, date and signature Name, date and signature
A-Star Technical Services Pte Ltd Yongnam Engineering & Construction Pte Ltd
FORM No.: ATS/QCP/VT/01 REV.01
VISUAL EXAMINATION REPORT Page: 1 of 1
###
Report No : : Client :
Date of test : : Test conducted by :
Acceptance Standard : : BS EN ISO 15614-1 Description :

Ground As Welded Material


Plate Pipe
Visual Weld EN 10025-4 S460M
NA Yes Length 500 mm Dia. : NA
Thk 25 mm Thk : NA Heat Treatment NA

Type Of Equipment Used During Test . (Tick box)

Ruler ü Welding gauge ü Magnifying Glass û Others û

Welding Types of imperfection


PQR no: / Welder Identification Type of Joint Result Remarks
Process
1 2 3 4 5 6 7 8 9 10 11 12

û û û NA NA û NA û NA NA û û Accepted

1. Crack 7. Shrinkage groove


2. Crater crack 8. Excess weld metal (Butt weld)
3. Surface pore 9. Excessive convexity (Fillet weld)
4. Lack of fusion 10. Excess penetration
5. Incomplete root penetration 11. Incomplete filled groove (Butt) / Insufficent throat (Fillet) YES: ü NO: û
6. Under cut 12. Others (Slag,poor restart,stray arc,Spatter)

……………………………………………………… ………………………………………………………………
Examiner or examining body Manufacturer
Name, date and signature Name, date and signature
FORM No.: ATS/QCP/VT/01 REV.01
A-STAR TESTING & INSPECTION (S) Pte Ltd
No.05 , Soon Lee Street,Pionner Point,#3-36/37, Singapore 627607
Tel: (65)62616162 / 93829286 / fax: (65)62616163
Email: admin@astartesting.com.sg / Website: www.astartesting.com.sg

VISUAL EXAMINATION REPORT Page: 1 of 1


###
Report No : : ATI-YNEC-PQR-VI-005 Client : Yongam Engineering & Construction Pte Ltd
Date of test : : 23.01.19 Test conducted by: A-Star Technical Service (s) Pte Ltd
Acceptance Standard : : BS EN ISO 15614-1 Description : Welding procedure qualification test plate

Ground As Welded Material


Plate Pipe
Visual Weld EN 10025-4 S460M
NA Yes Length 350 mm Dia. : NA
Thk 12 mm Thk : NA Heat Treatment NA

Type Of Equipment Used During Test . (Tick box)

Ruler ü Welding gauge ü Magnifying Glass û Others û

Welding Types of imperfection


PQR no: / Welder Identification Type of Joint Result Remarks
Process
1 2 3 4 5 6 7 8 9 10 11 12
FD/S460/SV-B/001/2G/PQR-312
Single V butt
136
Hossan Sabbir Md Shahadat
(FCAW-DS)
weld with û û û NA NA û NA û NA NA û û Accepted
IC.No.0 backing
63004170 (2G)

1. Crack 7. Shrinkage groove


2. Crater crack 8. Excess weld metal (Butt weld)
3. Surface pore 9. Excessive convexity (Fillet weld)
4. Lack of fusion 10. Excess penetration
5. Incomplete root penetration 11. Incomplete filled groove (Butt) / Insufficent throat (Fillet) YES: ü NO: û
6. Under cut 12. Others (Slag,poor restart,stray arc,Spatter)

……………………………………………………… ………………………………………………………………
Examiner or examining body Manufacturer
Name, date and signature Name, date and signature
A-Star Technical Services Pte Ltd Yongnam Engineering & Construction Pte Ltd
FORM No.: ATS/QCP/VT/01 REV.01
A-STAR TECHNICAL SERVICES PTE LTD.
No.05, Soon Lee Street #03-36/37, Pioneer Point, Singapore-627607

VISUAL EXAMINATION REPORT

Page: 1 of 1
###
ITEM NO: NA CONTRACTOR:YONGNAM ENGINEERING AND CONSTRUCTION PTE LTD

Ref:FD/S460 0413-53-3002-001 REV: 0 REPORT NOATS/VIS/001

GROUND AS WELDED
ACCEPTANCE VISUAL WELD
STANDARD : EN ISO 15614-1:2017 CONDITION NA Yes
PIPING CLASS :EN10025-4 S460M MATERIAL MATERIAL GRADE
PLATE PIPE EN10025-4 S460M
W.P.S. NO. : FD/S460/SV-B/002/3G Length : 350MM Dia. : NA HEAT TREATMENT
Thk : 25 MM Thk : NA PRE NA POST NA

TYPE OF EQUIPMENT USED DURING TEST. (TICK BOX)

RULE WELDING MAGNIFYING OTHERS


NA NA NA INSPECTION MIRROR
EQUIPMENT GUAGE GLASS SPECIFY

WELD WELDING TYPE OF UNACCEPTABLE INDICATIONS ACCEPT REJECT


NO. PROCESS WELD ROUNDED ELONGATED CRACK NON-FUSION U./C.

01 FCAW Butt NA NA NA NA NA Yes NA

SKETCH OR COMMENTS/RESTICTIONS

FINAL SURFACES REQUIRED BLEND GRINDING DURING EXAMINATION YES: NA NO:

COMPLETED BY CONTRACTOR YONG NAM


ENGINEERING

COMPANY A-STAR TECHNICAL SERVICES PTE LTD

SIGNATURE

NAME

DATE

1. No Part of this report may be reproduced, except in full, without the prior written permission of A-Star Testing & Inspection (S) Pte Ltd.
2. A-Star Testing & Inspection (S) Pte Ltd warrants that it has exercised reasonable care and diligence in preforming in test and inspections,
but no warranties implied or otherwise is given with respect to
the test or inspection provided in this report.
3.The customer shall determine the suitability of the test results for the intended us. Under no circumstance shall A-Star Testing &
Inspections Pte Ltd be liable any direct or indirect lose or damages
however missing from the use of the information in this report.

FORM No.: ATS/QCP/VT/01 REV.01


S.NO NAME W.NO POSITION RT VIS
1 Miah salim 273 6G 21 ACC
2 Hadaythwalla mohammad 1069 6G 19 ACC
3 Selim kazi 21 6G 22 ACC
4 Hasan mohammed kamural 112 6G 20 ACC
5 Shakil mohammad 980 6G 23 ACC
6 Habibullah mohammed 2 6G 25 ACC
7 Anwar 963 6G 24 ACC
8 Sadam 12 6G 26 REJ
9 Peng shixin 603 4G 28 REJ
10 Rahman masudur 829 3G 29 ACC
11 Sanu 1344 3G 30 ACC
12 Shahporan mohammad 1476 4G 31 ACC
13 Md shah alam 1020 4G 27 ACC
14 Alom jahangir 1698 6G 1 ACC
15 Hasan foysal 1077 6G 2 ACC
16 Islam mohammed tazul 393 6G 3 ACC
17 Ramachandran gopalakrishnan 4 6G 4 ACC
18 Sadequajaman 567 6G 5 ACC
19 vellaiya naidu ravichandran 502 6G 6 ACC
20 Auwal abdul 3G REJ
21 Faruk 3G 32 ACC
22 Islam monirul 3G REJ
23 Khan md ismail 3G REJ
24 Satter md abdus 3G REJ
25 Pothiyappan chandrasekaran 127 6G 35 ACC
26 hosain uzzal 1087 6G 33 ACC
27 Ramachandran gopalakrishnan 4 6G 36 ACC
28 Islam mohammed tazul 393 6G 34 ACC
29 Sarangapany murugesan 1000 6G 7 ACC
30 singaram arumugam 909 6G 8 ACC
31 Bahuddin md 944 3G 37 ACC
32 Bashir 1461 3G 39 REJ
33 Rasal 1171 3G 38 ACC
34 Ahammad hafiz 1109 3G 40 ACC
35 Miah kajal 1525 3G 41 ACC
36 Chen shaoqing 679 4G 42 ACC
37 Miah milon 611 3G 47 REJ
38 Liu song qing 19 4G 43 ACC
39 Sarker mamun 1175 4G 44 ACC
40 Md rakib khan 1177 4G 46 REJ
41 Zhang song xun 791 4G 45 ACC
42 Bashir 1461 3G 48 ACC
43 Gaji moshin 1149 3G 49 ACC
44 Miah sabuj 1787 3G 50 ACC
45 Rahman mahabubur 1788 3G 51 ACC
46 Bepari rezaul 734 3G ACC
47 Hossain anowar 1125 3G ACC
48 Rana rashel 1131 3G ACC
49 Satter md abdus 1120 3G ACC
50 Shahin 64 3G ACC
51 Ai amin mohammad 1686 3G
52 Bapari moklash 3G
53 Li yanqi 617 3G
54 Lu Bing 684 3G
55 Lu diankang 685 3G
56 Mostafa golam 1017 3G
57 Rifaz 3G
58 Salam md 766 3G
59 Sikder md nabin 847 3G
60 Tuhin 1687 3G
61 Uzzaman ali 1228 3G
62 Yousuf 3G
63 Islam ariful 3G
64 Kamal 3G
65 Bepair 3G
66 Baiged 3G
67 Asif 3G
68 Islam md rafiqul 965 3G
69 Alam shana 1217 4G
70 Mah rubal 1798 3G
71 Sikder md nabin 847 3G
72 Peng shixin 4G
73 Md rakib khan 4G
74 Miah milon 611 3G
75 Mostafa golam 1017 3G
76 Islam ariful 1769 3G
77 Kapi uddin 3G
78 Bbepari rezaul 3G
79 Shahin somez 3G
DATE process
2/25/2019 FCAW-IS Submitted 20-Mar-19 V-1
2/25/2019 FCAW-IS Submitted 20-Mar-19 V-1
2/25/2019 FCAW-IS Submitted 20-Mar-19 V-1
2/25/2019 FCAW-IS Submitted 20-Mar-19 V-1
2/25/2019 FCAW-IS Submitted 20-Mar-19 V-1
2/26/2019 FCAW-IS Submitted 20-Mar-19 V-2
2/26/2019 FCAW-IS Submitted 20-Mar-19 V-2
2/26/2019 FCAW-IS
3/4/2019 SMAW V-3
3/4/2019 FCAW-IS V-3
3/4/2019 FCAW-IS V-3
3/4/2019 FCAW-IS V-3
3/4/2019 FCAW-IS V-3
3/5/2019 FCAW-DS Submitted 19-Mar-19 V-1/18
3/5/2019 FCAW-DS Submitted 19-Mar-19 V-1/18
3/5/2019 FCAW-DS Submitted 19-Mar-19 V-1/18
3/5/2019 FCAW-DS Submitted 19-Mar-19 V-1/18
3/5/2019 FCAW-DS Submitted 19-Mar-19 V-1/18 OLD DATE
3/5/2019 FCAW-DS Submitted 19-Mar-19 V-1/18 24/12/18
3/6/2019 FCAW-IS
3/6/2019 FCAW-IS V-4
3/6/2019 FCAW-IS
3/6/2019 FCAW-IS
3/6/2019 FCAW-IS
3/11/2019 FCAW-IS V-5
3/11/2019 FCAW-IS V-5
3/11/2019 FCAW-IS V-5
3/11/2019 FCAW-IS V-5
3/11/2019 MMAW Submitted 20-Mar-19 V-2/18 OLD DATE
3/11/2019 MMAW Submitted 20-Mar-19 V-2/18 24/12/18
3/13/2019 FCAW-DS V-6
3/13/2019 FCAW-DS V-6
3/13/2019 FCAW-DS V-6
3/13/2019 FCAW-IS V-6
3/13/2019 FCAW-IS V-6
3/19/2019 SMAW V-7
3/19/2019 FCAW V-7
3/19/2019 FCAW V-7
3/19/2019 SMAW V-7
3/19/2019 FCAW V-7
3/19/2019 FCAW V-7
3/21/2019 FCAW-DS V-8
3/21/2019 FCAW-DS V-8
3/21/2019 FCAW-DS V-8
3/21/2019 FCAW-DS V-8
3/25/2019 FCAW-IS V-9
3/25/2019 FCAW-IS V-9
3/25/2019 FCAW-IS V-9
3/25/2019 FCAW-IS V-9
3/25/2019 FCAW-IS V-9
3/26/2019 FCAW-IS V-10
3/26/2019 FCAW-IS V-10
3/26/2019 FCAW-IS V-10
3/26/2019 FCAW-IS V-10
3/26/2019 FCAW-IS V-10
3/26/2019 FCAW-IS V-10
3/26/2019 FCAW-IS V-10
3/26/2019 FCAW-IS V-10
3/26/2019 FCAW-IS V-10
3/26/2019 FCAW-IS V-10
3/26/2019 FCAW-IS V-10
3/27/2019 FCAW-IS V-11
3/27/2019 FCAW-IS V-11
3/27/2019 FCAW-IS V-11
3/27/2019 FCAW-IS V-11
3/27/2019 FCAW-IS V-11
3/27/2019 FCAW-IS V-11
4/25/2019 SMAW V-11
4/25/2019 FCAW V-11
4/25/2019 SMAW V-11
4/25/2019 SMAW V-11
4/25/2019 FCAW V-11
4/25/2019 FCAW V-11
4/25/2019 FCAW V-11
4/25/2019 SMAW V-11
4/25/2019 SMAW V-11
4/25/2019 SMAW V-11
4/25/2019 FCAW V-11
4/25/2019 FCAW V-11
A-STAR TESTING & INSPECTION (S) Pte Ltd
No.05 , Soon Lee Street,Pionner Point,#3-36/37, Singapore 627607
Tel: (65)62616162 / 93829286 / fax: (65)62616163
Email: admin@astartesting.com.sg / Website: www.astartesting.com.sg

VISUAL EXAMINATION REPORT Page: 1 of 1


###
Report No. : ATI/YNEC/WQT/VI/001 Client : Yongam Engineering & Construction Pte Ltd
Date of test : 25.02.18 Test conducted by: A-Star Testing & Inspection (s) Pte Ltd
Acceptance Standard : BS EN ISO 9606-1 Clause 7 Description : Welder Qualification Test Plate

Ground As Welded Material


Plate Pipe
Visual Weld BS EN 10210 S355 J2H
NA Yes Length NA Dia. : 193.7 mm
Thk NA Thk : 12.5 mm Heat Treatment NA

Type Of Equipment Used During Test . (Tick box)

Ruler ü Welding gauge ü Magnifying Glass û Others û

Welder name / Welding Types of imperfection


Type of Joint Result Remarks
Identification Process
1 2 3 4 5 6 7 8 9 10 11 12

Alom jahangri
Single bevel
IC.No.0 136
63049131 (FCAW-DS)
butt weld with û û û NA NA û NA û NA NA û û Accepted
backing
(6G)

Hasan foysal Single bevel


136
IC.No.0 6273065-
(FCAW-DS)
butt weld with û û û NA NA û NA û NA NA û û Accepted
(6G) backing

Islam mohammed tazul


Single bevel
136
IC.No.0 62081287 (FCAW-DS)
butt weld with û û û NA NA û NA û NA NA û û Accepted
backing
(6G)

Ramachandran
gopalakrishnan Single bevel
136
IC.No.0
(FCAW-DS)
butt weld with û û û NA NA û NA û NA NA û û Accepted
3142044- backing
(6G)

Sadequajaman
Single bevel
IC.No.0 136
62400846 (FCAW-DS)
butt weld with û û û NA NA û NA û NA NA û û Accepted
backing
(6G)

Vellaiya naidu
ravichandran Single bevel
136
IC.No.0
(FCAW-DS)
butt weld with û û û NA NA û NA û NA NA û û Accepted
34002193 backing
(6G)

Sarangapany murugesan
Single bevel
111
IC.No.0 33466676 (SMAW)
butt weld with û û û NA NA û NA û NA NA û û Accepted
backing
(6G)

Singaram arumugam
Single bevel
111
IC.No.0 34400814 (SMAW)
butt weld with û û û NA NA û NA û NA NA û û Accepted
backing
(6G)

1. Crack 7. Shrinkage groove


2. Crater crack 8. Excess weld metal (Butt weld)
3. Surface pore 9. Excessive convexity (Fillet weld)
4. Lack of fusion 10. Excess penetration
5. Incomplete root penetration 11. Incomplete filled groove (Butt) / Insufficent throat (Fillet) YES: ü NO: û
6. Under cut 12. Others (Slag,poor restart,stray arc,Spatter)

……………………………………………………… ………………………………………………………………
Examiner or examining body Manufacturer
Name, date and signature Name, date and signature
A-Star Technical Services Pte Ltd Yongnam Engineering & Construction Pte Ltd
FORM No.: ATS/QCP/VT/01 REV.01
A-STAR TESTING & INSPECTION (S) Pte Ltd
No.05 , Soon Lee Street,Pionner Point,#3-36/37, Singapore 627607
Tel: (65)62616162 / 93829286 / fax: (65)62616163
Email: admin@astartesting.com.sg / Website: www.astartesting.com.sg

VISUAL EXAMINATION REPORT Page: 1 of 1


###
Report No. : ATI/YNEC/WQT/VI/001 Client : Yongam Engineering & Construction Pte Ltd
Date of test : 26.02.18 Test conducted by : A-Star Testing & Inspection (s) Pte Ltd
Acceptance Standard : BS EN ISO 9606-1 Clause 7
Component : Welder Qualification Test Plate
Ground As Welded
Visual Weld
NA Yes
Material
Plate Pipe
Carbon steel
Length NA Dia. : 193.7 mm
Thk NA Thk : 12.5 mm Heat Treatment NA

Type Of Equipment Used During Test . (Tick box)

Ruler ü Welding gauge ü Magnifying Glass û Others û

Welding Type of
Identification Result Remarks
Process Joint
1 2 3 4 5 6 7 8 9 10 11 12

Habibullah mohammed
Single
114
IC.No.0 61781218 (FCAW-IS)
bevel butt û û û û û û û û NA û û û Accepted
weld
(6G)

Anwar Single
114
IC.No.0
(FCAW-IS)
bevel butt û û û û û û û û NA û û û Accepted
63155640 weld
(6G)

Shakil mohammad Single


114
(FCAW-IS)
bevel butt û û û û û û û û NA û û û Accepted
IC.No.0 63341495 weld
(6G)
1. Crack 7. Shrinkage groove
2. Crater crack 8. Excess weld metal (Butt weld)
3. Surface pore 9. Excessive convexity (Fillet weld)
4. Lack of fusion 10. Excess penetration
5. Incomplete root penetration 11. Incomplete filled groove (Butt) / Insufficent throat (Fillet) YES: ü NO: û
6. Under cut 12. Others (poor restart,stray arc,Spatter)

Completed by Examiner Client

A-Star Testing & Inspection


Company YNEC
Pte Ltd

Signature

Name

Date

1. No Part of this report may be reproduced, except in full, without the prior written permission of A-Star Testing & Inspection (S) Pte Ltd.
2. A-Star Testing & Inspection (S) Pte Ltd warrants that it has exercised reasonable care and diligence in preforming in test and inspections, but no
warranties implied or otherwise is given with respect to
the test or inspection provided in this report.
3.The customer shall determine the suitability of the test results for the intended us. Under no circumstance shall A-Star Testing & Inspections Pte Ltd be
liable any direct or indirect lose or damages
however missing from the use of the information in this report.

FORM No.: ATS/QCP/VT/01 REV.01


A-STAR TESTING & INSPECTION (S) Pte Ltd
No.05 , Soon Lee Street,Pionner Point,#3-36/37, Singapore 627607
Tel: (65)62616162 / 93829286 / fax: (65)62616163
Email: admin@astartesting.com.sg / Website: www.astartesting.com.sg

VISUAL EXAMINATION REPORT Page: 1 of 1


###
Report No : : ATI-YNEC-PQR-VI-001 Client : Yongam Engineering & Construction Pte Ltd
Date of test : : 18.01.19 Test conducted by: A-Star Technical Service (s) Pte Ltd
Acceptance Standard : : BS EN ISO 15614-1 Description : Welding procedure qualification test plate

Ground As Welded Material


Plate Pipe
Visual Weld EN 10025-4 S460M
NA Yes Length 350 mm Dia. : NA
Thk 25 mm Thk : NA Heat Treatment NA

Type Of Equipment Used During Test . (Tick box)

Ruler ü Welding gauge ü Magnifying Glass û Others û

Welding Types of imperfection


PQR no: / Welder Identification Type of Joint Result Remarks
Process
1 2 3 4 5 6 7 8 9 10 11 12
FD/S460/SV-B/002/2G/PQR-314
Single V butt
136
Hossan Sabbir Md Shahadat
(FCAW-DS)
weld with û û û NA NA û NA û NA NA û û Accepted
IC.No.0 backing
63004170 (2G)

1. Crack 7. Shrinkage groove


2. Crater crack 8. Excess weld metal (Butt weld)
3. Surface pore 9. Excessive convexity (Fillet weld)
4. Lack of fusion 10. Excess penetration
5. Incomplete root penetration 11. Incomplete filled groove (Butt) / Insufficent throat (Fillet) YES: ü NO: û
6. Under cut 12. Others (Slag,poor restart,stray arc,Spatter)

……………………………………………………… ………………………………………………………………
Examiner or examining body Manufacturer
Name, date and signature Name, date and signature
A-Star Technical Services Pte Ltd Yongnam Engineering & Construction Pte Ltd
FORM No.: ATS/QCP/VT/01 REV.01
A-STAR TESTING & INSPECTION (S) Pte Ltd
No.05 , Soon Lee Street,Pionner Point,#3-36/37, Singapore 627607
Tel: (65)62616162 / 93829286 / fax: (65)62616163
Email: admin@astartesting.com.sg / Website: www.astartesting.com.sg

VISUAL EXAMINATION REPORT Page: 1 of 1


###
Report No : : ATI-YNEC-PQR-VI-002 Client : Yongam Engineering & Construction Pte Ltd
Date of test : : 18.01.19 Test conducted by: A-Star Technical Service (s) Pte Ltd
Acceptance Standard : : BS EN ISO 15614-1 Description : Welding procedure qualification test plate

Ground As Welded Material


Plate Pipe
Visual Weld EN 10025-4 S460M
NA Yes Length 350 mm Dia. : NA
Thk 25 mm Thk : NA Heat Treatment NA

Type Of Equipment Used During Test . (Tick box)

Ruler ü Welding gauge ü Magnifying Glass û Others û

Welding Types of imperfection


PQR no: / Welder Identification Type of Joint Result Remarks
Process
1 2 3 4 5 6 7 8 9 10 11 12
FD/S460/SV-B/002/3G/PQR-315
Single V butt
136
Selvaraju Iyappan
(FCAW-DS)
weld with û û û NA NA û NA û NA NA û û Accepted
IC.No.0 33996233 backing
(3G)

1. Crack 7. Shrinkage groove


2. Crater crack 8. Excess weld metal (Butt weld)
3. Surface pore 9. Excessive convexity (Fillet weld)
4. Lack of fusion 10. Excess penetration
5. Incomplete root penetration 11. Incomplete filled groove (Butt) / Insufficent throat (Fillet) YES: ü NO: û
6. Under cut 12. Others (Slag,poor restart,stray arc,Spatter)

……………………………………………………… ………………………………………………………………
Examiner or examining body Manufacturer
Name, date and signature Name, date and signature
A-Star Technical Services Pte Ltd Yongnam Engineering & Construction Pte Ltd
FORM No.: ATS/QCP/VT/01 REV.01
A-STAR TESTING & INSPECTION (S) Pte Ltd
No.05 , Soon Lee Street,Pionner Point,#3-36/37, Singapore 627607
Tel: (65)62616162 / 93829286 / fax: (65)62616163
Email: admin@astartesting.com.sg / Website: www.astartesting.com.sg

VISUAL EXAMINATION REPORT Page: 1 of 1


###
Report No : : ATI-YNEC-PQR-VI-004 Client : Yongam Engineering & Construction Pte Ltd
Date of test : : 23.01.19 Test conducted by : A-Star Technical Service (s) Pte Ltd
Acceptance Standard : : BS EN ISO 15614-1 Description : Welding procedure qualification test plate

Ground As Welded Material


Plate Pipe
Visual Weld EN 10025-4 S460M
NA Yes Length 450 mm Dia. : NA
Thk 100 mm Thk : NA Heat Treatment NA

Type Of Equipment Used During Test . (Tick box)

Ruler ü Welding gauge ü Magnifying Glass û Others û

Welding Types of imperfection


PQR no: / Welder Identification Type of Joint Result Remarks
Process
1 2 3 4 5 6 7 8 9 10 11 12
FD/S460/SV-B/003/2G/PQR-316
Single V butt
136
Hossan Sabbir Md Shahadat
(FCAW-DS)
weld with û û û NA NA û NA û NA NA û û Accepted
IC.No.0 backing
63004170 (PC)

1. Crack 7. Shrinkage groove


2. Crater crack 8. Excess weld metal (Butt weld)
3. Surface pore 9. Excessive convexity (Fillet weld)
4. Lack of fusion 10. Excess penetration
5. Incomplete root penetration 11. Incomplete filled groove (Butt) / Insufficent throat (Fillet) YES: ü NO: û
6. Under cut 12. Others (Slag,poor restart,stray arc,Spatter)

……………………………………………………… ………………………………………………………………
Examiner or examining body Manufacturer
Name, date and signature Name, date and signature
A-Star Technical Services Pte Ltd Yongnam Engineering & Construction Pte Ltd
FORM No.: ATS/QCP/VT/01 REV.01
A-STAR TESTING & INSPECTION (S) Pte Ltd
No.05 , Soon Lee Street,Pionner Point,#3-36/37, Singapore 627607
Tel: (65)62616162 / 93829286 / fax: (65)62616163
Email: admin@astartesting.com.sg / Website: www.astartesting.com.sg

VISUAL EXAMINATION REPORT Page: 1 of 1


###
Report No : : ATI-YNEC-PQR-VI-006 Client : Yongam Engineering & Construction Pte Ltd
Date of test : : 24.01.19 Test conducted by: A-Star Technical Service (s) Pte Ltd
Acceptance Standard : : BS EN ISO 15614-1 Description : Welding procedure qualification test plate

Ground As Welded Material


Plate Pipe
Visual Weld EN 10210- S355J2H
NA Yes Length NA Dia. : 193.7
Thk NA Thk : 12.5 mm Heat Treatment NA

Type Of Equipment Used During Test . (Tick box)

Ruler ü Welding gauge ü Magnifying Glass û Others û

Welding Types of imperfection


PQR no: / Welder Identification Type of Joint Result Remarks
Process
1 2 3 4 5 6 7 8 9 10 11 12
FD/SV-B/004/12.5t/6G/PQR-320
Single V butt
136
Hossan Sabbir Md Shahadat
(FCAW-DS)
weld with û û û NA NA û NA û NA NA û û Accepted
IC.No.0 backing
63004170 (6G)

1. Crack 7. Shrinkage groove


2. Crater crack 8. Excess weld metal (Butt weld)
3. Surface pore 9. Excessive convexity (Fillet weld)
4. Lack of fusion 10. Excess penetration
5. Incomplete root penetration 11. Incomplete filled groove (Butt) / Insufficent throat (Fillet) YES: ü NO: û
6. Under cut 12. Others (Slag,poor restart,stray arc,Spatter)

……………………………………………………… ………………………………………………………………
Examiner or examining body Manufacturer
Name, date and signature Name, date and signature
A-Star Technical Services Pte Ltd Yongnam Engineering & Construction Pte Ltd
FORM No.: ATS/QCP/VT/01 REV.01
A-STAR TESTING & INSPECTION (S) Pte Ltd
No.05 , Soon Lee Street,Pionner Point,#3-36/37, Singapore 627607
Tel: (65)62616162 / 93829286 / fax: (65)62616163
Email: admin@astartesting.com.sg / Website: www.astartesting.com.sg

VISUAL EXAMINATION REPORT Page: 1 of 1


###
Report No : : ATI-YNEC-PQR-VI-012 Client : Yongam Engineering & Construction Pte Ltd
Date of test : : 20.02.19 Test conducted by: A-Star Technical Service (s) Pte Ltd
Acceptance Standard : : BS EN ISO 15614-1 Description : Welding procedure qualification test plate

Ground As Welded Material


Plate Pipe
Visual Weld EN 10210- S355J2H
NA Yes Length NA Dia. : 193.7
Thk NA Thk : 12.5 mm Heat Treatment NA

Type Of Equipment Used During Test . (Tick box)

Ruler ü Welding gauge ü Magnifying Glass û Others û

Welding Types of imperfection


PQR no: / Welder Identification Type of Joint Result Remarks
Process
1 2 3 4 5 6 7 8 9 10 11 12
FI/SV-B/004/12.5t/6G/PQR-322
Single V butt
114
Ali Shahjahan
(FCAW-IS)
weld with û û û NA NA û NA û NA NA û û Accepted
IC.No.0 62150955 backing
(6G)

1. Crack 7. Shrinkage groove


2. Crater crack 8. Excess weld metal (Butt weld)
3. Surface pore 9. Excessive convexity (Fillet weld)
4. Lack of fusion 10. Excess penetration
5. Incomplete root penetration 11. Incomplete filled groove (Butt) / Insufficent throat (Fillet) YES: ü NO: û
6. Under cut 12. Others (Slag,poor restart,stray arc,Spatter)

……………………………………………………… ………………………………………………………………
Examiner or examining body Manufacturer
Name, date and signature Name, date and signature
A-Star Technical Services Pte Ltd Yongnam Engineering & Construction Pte Ltd
FORM No.: ATS/QCP/VT/01 REV.01
A-STAR TESTING & INSPECTION (S) Pte Ltd
No.05 , Soon Lee Street,Pionner Point,#3-36/37, Singapore 627607
Tel: (65)62616162 / 93829286 / fax: (65)62616163
Email: admin@astartesting.com.sg / Website: www.astartesting.com.sg

VISUAL EXAMINATION REPORT Page: 1 of 1


###
Report No : : ATI-YNEC-PQR-VI-010 Client : Yongam Engineering & Construction Pte Ltd
Date of test : : 19.02.19 Test conducted by : A-Star Technical Service (s) Pte Ltd
Acceptance Standard : : BS EN ISO 15614-1 Description : Welding procedure qualification test plate

Ground As Welded Material


Plate Pipe
Visual Weld EN 10210-1 S355J0H
NA Yes Length NA Dia. : 273
Thk NA Thk : 40 mm Heat Treatment NA

Type Of Equipment Used During Test . (Tick box)

Ruler ü Welding gauge ü Magnifying Glass û Others û

Welding Types of imperfection


PQR no: / Welder Identification Type of Joint Result Remarks
Process
1 2 3 4 5 6 7 8 9 10 11 12
FI/SV-B/005/40t/6G/PQR-323
Single V butt
114
Hossan Md Makbul
(FCAW-IS)
weld with û û û NA NA û NA û NA NA û û Accepted
IC.No.0 62052899 backing
(H-L045)

1. Crack 7. Shrinkage groove


2. Crater crack 8. Excess weld metal (Butt weld)
3. Surface pore 9. Excessive convexity (Fillet weld)
4. Lack of fusion 10. Excess penetration
5. Incomplete root penetration 11. Incomplete filled groove (Butt) / Insufficent throat (Fillet) YES: ü NO: û
6. Under cut 12. Others (Slag,poor restart,stray arc,Spatter)

……………………………………………………… ………………………………………………………………
Examiner or examining body Manufacturer
Name, date and signature Name, date and signature
A-Star Technical Services Pte Ltd Yongnam Engineering & Construction Pte Ltd
FORM No.: ATS/QCP/VT/01 REV.01
A-STAR TESTING & INSPECTION (S) Pte Ltd
No.05 , Soon Lee Street,Pionner Point,#3-36/37, Singapore 627607
Tel: (65)62616162 / 93829286 / fax: (65)62616163
Email: admin@astartesting.com.sg / Website: www.astartesting.com.sg

VISUAL EXAMINATION REPORT Page: 1 of 1


###
Report No : : ATI-YNEC-PQR-VI-011 Client : Yongam Engineering & Construction Pte Ltd
Date of test : : 19.02.19 Test conducted by: A-Star Technical Service (s) Pte Ltd
Acceptance Standard : : BS EN ISO 15614-1 Description : Welding procedure qualification test plate

Ground As Welded Material


Plate Pipe
Visual Weld EN 10210- S355J2H
NA Yes Length NA Dia. : 193.7
Thk NA Thk : 12.5 mm Heat Treatment NA

Type Of Equipment Used During Test . (Tick box)

Ruler ü Welding gauge ü Magnifying Glass û Others û

Welding Types of imperfection


PQR no: / Welder Identification Type of Joint Result Remarks
Process
1 2 3 4 5 6 7 8 9 10 11 12
MM/SV-B/004/12.5t/6G/PQR-324
Single V butt
111
Ali Shahjahan
(MMAW)
weld with û û û NA NA û NA û NA NA û û Accepted
IC.No.0 62150955 backing
(6G)

1. Crack 7. Shrinkage groove


2. Crater crack 8. Excess weld metal (Butt weld)
3. Surface pore 9. Excessive convexity (Fillet weld)
4. Lack of fusion 10. Excess penetration
5. Incomplete root penetration 11. Incomplete filled groove (Butt) / Insufficent throat (Fillet) YES: ü NO: û
6. Under cut 12. Others (Slag,poor restart,stray arc,Spatter)

……………………………………………………… ………………………………………………………………
Examiner or examining body Manufacturer
Name, date and signature Name, date and signature
A-Star Technical Services Pte Ltd Yongnam Engineering & Construction Pte Ltd
FORM No.: ATS/QCP/VT/01 REV.01
A-STAR TESTING & INSPECTION (S) Pte Ltd
No.05 , Soon Lee Street,Pionner Point,#3-36/37, Singapore 627607
Tel: (65)62616162 / 93829286 / fax: (65)62616163
Email: admin@astartesting.com.sg / Website: www.astartesting.com.sg

VISUAL EXAMINATION REPORT Page: 1 of 1


###
Report No : : ATI-YNEC-PQR-VI-013 Client : Yongam Engineering & Construction Pte Ltd
Date of test : : 21.02.19 Test conducted by : A-Star Technical Service (s) Pte Ltd
Acceptance Standard : : BS EN ISO 15614-1 Description : Welding procedure qualification test plate

Ground As Welded Material


Plate Pipe
Visual Weld EN 10210-1 S355J0H
NA Yes Length NA Dia. : 273
Thk NA Thk : 40 mm Heat Treatment NA

Type Of Equipment Used During Test . (Tick box)

Ruler ü Welding gauge ü Magnifying Glass û Others û

Welding Types of imperfection


PQR no: / Welder Identification Type of Joint Result Remarks
Process
1 2 3 4 5 6 7 8 9 10 11 12
MM/SV-B/005/40t/6G/PQR-325
Single V butt
111
Hossan Md Makbul
(MMAW)
weld with û û û NA NA û NA û NA NA û û Accepted
IC.No.0 62052899 backing
(H-L045)

1. Crack 7. Shrinkage groove


2. Crater crack 8. Excess weld metal (Butt weld)
3. Surface pore 9. Excessive convexity (Fillet weld)
4. Lack of fusion 10. Excess penetration
5. Incomplete root penetration 11. Incomplete filled groove (Butt) / Insufficent throat (Fillet) YES: ü NO: û
6. Under cut 12. Others (Slag,poor restart,stray arc,Spatter)

……………………………………………………… ………………………………………………………………
Examiner or examining body Manufacturer
Name, date and signature Name, date and signature
A-Star Technical Services Pte Ltd Yongnam Engineering & Construction Pte Ltd
FORM No.: ATS/QCP/VT/01 REV.01
A-STAR TESTING & INSPECTION (S) Pte Ltd
No.05 , Soon Lee Street,Pionner Point,#3-36/37, Singapore 627607
Tel: (65)62616162 / 93829286 / fax: (65)62616163
Email: admin@astartesting.com.sg / Website: www.astartesting.com.sg

VISUAL EXAMINATION REPORT Page: 1 of 1


###
Report No : : ATI-YNEC-PQR-VI-016 Client : Yongam Engineering & Construction Pte Ltd
Date of test : : 15.03.19 Test conducted by: A-Star Technical Service (s) Pte Ltd
Acceptance Standard : : BS EN ISO 15614-1 Description : Welding procedure qualification test plate

Ground As Welded Material


Plate Pipe
Visual Weld EN 10025-4 S460M
NA Yes Length 350 mm Dia. : NA
Thk 12 mm Thk : NA Heat Treatment NA

Type Of Equipment Used During Test . (Tick box)

Ruler ü Welding gauge ü Magnifying Glass û Others û

Welding Types of imperfection


PQR no: / Welder Identification Type of Joint Result Remarks
Process
1 2 3 4 5 6 7 8 9 10 11 12
MM/S460/SV-B/001/2G/PQR-326
Single V butt
111
Ali Shahjahan
(MMAW)
weld with û û û NA NA û NA û NA NA û û Accepted
IC.No.0 62150955 backing
(2G)

1. Crack 7. Shrinkage groove


2. Crater crack 8. Excess weld metal (Butt weld)
3. Surface pore 9. Excessive convexity (Fillet weld)
4. Lack of fusion 10. Excess penetration
5. Incomplete root penetration 11. Incomplete filled groove (Butt) / Insufficent throat (Fillet) YES: ü NO: û
6. Under cut 12. Others (Slag,poor restart,stray arc,Spatter)

……………………………………………………… ………………………………………………………………
Examiner or examining body Manufacturer
Name, date and signature Name, date and signature
A-Star Technical Services Pte Ltd Yongnam Engineering & Construction Pte Ltd
FORM No.: ATS/QCP/VT/01 REV.01
A-STAR TESTING & INSPECTION (S) Pte Ltd
No.05 , Soon Lee Street,Pionner Point,#3-36/37, Singapore 627607
Tel: (65)62616162 / 93829286 / fax: (65)62616163
Email: admin@astartesting.com.sg / Website: www.astartesting.com.sg

VISUAL EXAMINATION REPORT Page: 1 of 1


###
Report No : : ATI-YNEC-PQR-VI-014 Client : Yongam Engineering & Construction Pte Ltd
Date of test : : 15.03.19 Test conducted by: A-Star Technical Service (s) Pte Ltd
Acceptance Standard : : BS EN ISO 15614-1 Description : Welding procedure qualification test plate

Ground As Welded Material


Plate Pipe
Visual Weld EN 10025-4 S460M
NA Yes Length 350 mm Dia. : NA
Thk 12 mm Thk : NA Heat Treatment NA

Type Of Equipment Used During Test . (Tick box)

Ruler ü Welding gauge ü Magnifying Glass û Others û

Welding Types of imperfection


PQR no: / Welder Identification Type of Joint Result Remarks
Process
1 2 3 4 5 6 7 8 9 10 11 12
MM/S460/SV-B/001/3G/PQR-327
Single V butt
111
Hossian Md Makbul
(MMAW)
weld with û û û NA NA û NA û NA NA û û Accepted
IC.No.0 backing
62052899 (3G)

1. Crack 7. Shrinkage groove


2. Crater crack 8. Excess weld metal (Butt weld)
3. Surface pore 9. Excessive convexity (Fillet weld)
4. Lack of fusion 10. Excess penetration
5. Incomplete root penetration 11. Incomplete filled groove (Butt) / Insufficent throat (Fillet) YES: ü NO: û
6. Under cut 12. Others (Slag,poor restart,stray arc,Spatter)

……………………………………………………… ………………………………………………………………
Examiner or examining body Manufacturer
Name, date and signature Name, date and signature
A-Star Technical Services Pte Ltd Yongnam Engineering & Construction Pte Ltd
FORM No.: ATS/QCP/VT/01 REV.01
A-STAR TESTING & INSPECTION (S) Pte Ltd
No.05 , Soon Lee Street,Pionner Point,#3-36/37, Singapore 627607
Tel: (65)62616162 / 93829286 / fax: (65)62616163
Email: admin@astartesting.com.sg / Website: www.astartesting.com.sg

VISUAL EXAMINATION REPORT Page: 1 of 1


###
Report No : : ATI-YNEC-PQR-VI-017 Client : Yongam Engineering & Construction Pte Ltd
Date of test : : 16.03.19 Test conducted by: A-Star Technical Service (s) Pte Ltd
Acceptance Standard : : BS EN ISO 15614-1 Description : Welding procedure qualification test plate

Ground As Welded Material


Plate Pipe
Visual Weld EN 10025-4 S460M
NA Yes Length 350 mm Dia. : NA
Thk 25 mm Thk : NA Heat Treatment NA

Type Of Equipment Used During Test . (Tick box)

Ruler ü Welding gauge ü Magnifying Glass û Others û

Welding Types of imperfection


PQR no: / Welder Identification Type of Joint Result Remarks
Process
1 2 3 4 5 6 7 8 9 10 11 12
MM/S460/SV-B/002/2G/PQR-328
Single V butt
111
Hossian Md Makbul
(MMAW)
weld with û û û NA NA û NA û NA NA û û Accepted
IC.No.0 backing
62052899 (2G)

1. Crack 7. Shrinkage groove


2. Crater crack 8. Excess weld metal (Butt weld)
3. Surface pore 9. Excessive convexity (Fillet weld)
4. Lack of fusion 10. Excess penetration
5. Incomplete root penetration 11. Incomplete filled groove (Butt) / Insufficent throat (Fillet) YES: ü NO: û
6. Under cut 12. Others (Slag,poor restart,stray arc,Spatter)

……………………………………………………… ………………………………………………………………
Examiner or examining body Manufacturer
Name, date and signature Name, date and signature
A-Star Technical Services Pte Ltd Yongnam Engineering & Construction Pte Ltd
FORM No.: ATS/QCP/VT/01 REV.01
A-STAR TESTING & INSPECTION (S) Pte Ltd
No.05 , Soon Lee Street,Pionner Point,#3-36/37, Singapore 627607
Tel: (65)62616162 / 93829286 / fax: (65)62616163
Email: admin@astartesting.com.sg / Website: www.astartesting.com.sg

VISUAL EXAMINATION REPORT Page: 1 of 1


###
Report No : : ATI-YNEC-PQR-VI-015 Client : Yongam Engineering & Construction Pte Ltd
Date of test : : 16.03.19 Test conducted by: A-Star Technical Service (s) Pte Ltd
Acceptance Standard : : BS EN ISO 15614-1 Description : Welding procedure qualification test plate

Ground As Welded Material


Plate Pipe
Visual Weld EN 10025-4 S460M
NA Yes Length 350 mm Dia. : NA
Thk 25 mm Thk : NA Heat Treatment NA

Type Of Equipment Used During Test . (Tick box)

Ruler ü Welding gauge ü Magnifying Glass û Others û

Welding Types of imperfection


PQR no: / Welder Identification Type of Joint Result Remarks
Process
1 2 3 4 5 6 7 8 9 10 11 12
MM/S460/SV-B/002/3G/PQR-329
Single V butt
111
Ali Shahjahan
(MMAW)
weld with û û û NA NA û NA û NA NA û û Accepted
IC.No.0 62150955 backing
(3G)

1. Crack 7. Shrinkage groove


2. Crater crack 8. Excess weld metal (Butt weld)
3. Surface pore 9. Excessive convexity (Fillet weld)
4. Lack of fusion 10. Excess penetration
5. Incomplete root penetration 11. Incomplete filled groove (Butt) / Insufficent throat (Fillet) YES: ü NO: û
6. Under cut 12. Others (Slag,poor restart,stray arc,Spatter)

……………………………………………………… ………………………………………………………………
Examiner or examining body Manufacturer
Name, date and signature Name, date and signature
A-Star Technical Services Pte Ltd Yongnam Engineering & Construction Pte Ltd
FORM No.: ATS/QCP/VT/01 REV.01
A-STAR TESTING & INSPECTION (S) Pte Ltd
No.05 , Soon Lee Street,Pionner Point,#3-36/37, Singapore 627607
Tel: (65)62616162 / 93829286 / fax: (65)62616163
Email: admin@astartesting.com.sg / Website: www.astartesting.com.sg

VISUAL EXAMINATION REPORT Page: 1 of 1


###
Report No : : ATI-YNEC-PQR-VI-018 Client : Yongam Engineering & Construction Pte Ltd
Date of test : : 01.04.19 Test conducted by: A-Star Technical Service (s) Pte Ltd
Acceptance Standard : : BS EN ISO 15614-1 Description : Welding procedure qualification test plate

Ground As Welded Material


Plate Pipe
Visual Weld EN 10025-4 S460M
NA Yes Length 350 mm Dia. : NA
Thk 12 mm Thk : NA Heat Treatment NA

Type Of Equipment Used During Test . (Tick box)

Ruler ü Welding gauge ü Magnifying Glass û Others û

Welding Types of imperfection


PQR no: / Welder Identification Type of Joint Result Remarks
Process
1 2 3 4 5 6 7 8 9 10 11 12
FI/S460/SV-B/001/2G/PQR-330
Single V butt
114
Shohel
(FCAW-IS)
weld with û û û NA NA û NA û NA NA û û Accepted
IC.No.0 6223671- backing
(2G)

1. Crack 7. Shrinkage groove


2. Crater crack 8. Excess weld metal (Butt weld)
3. Surface pore 9. Excessive convexity (Fillet weld)
4. Lack of fusion 10. Excess penetration
5. Incomplete root penetration 11. Incomplete filled groove (Butt) / Insufficent throat (Fillet) YES: ü NO: û
6. Under cut 12. Others (Slag,poor restart,stray arc,Spatter)

……………………………………………………… ………………………………………………………………
Examiner or examining body Manufacturer
Name, date and signature Name, date and signature
A-Star Technical Services Pte Ltd Yongnam Engineering & Construction Pte Ltd
FORM No.: ATS/QCP/VT/01 REV.01
A-STAR TESTING & INSPECTION (S) Pte Ltd
No.05 , Soon Lee Street,Pionner Point,#3-36/37, Singapore 627607
Tel: (65)62616162 / 93829286 / fax: (65)62616163
Email: admin@astartesting.com.sg / Website: www.astartesting.com.sg

VISUAL EXAMINATION REPORT Page: 1 of 1


###
Report No : : ATI-YNEC-PQR-VI-020 Client : Yongam Engineering & Construction Pte Ltd
Date of test : : 01.04.19 Test conducted by: A-Star Technical Service (s) Pte Ltd
Acceptance Standard : : BS EN ISO 15614-1 Description : Welding procedure qualification test plate

Ground As Welded Material


Plate Pipe
Visual Weld EN 10025-4 S460M
NA Yes Length 350 mm Dia. : NA
Thk 12 mm Thk : NA Heat Treatment NA

Type Of Equipment Used During Test . (Tick box)

Ruler ü Welding gauge ü Magnifying Glass û Others û

Welding Types of imperfection


PQR no: / Welder Identification Type of Joint Result Remarks
Process
1 2 3 4 5 6 7 8 9 10 11 12
FI/S460/SV-B/001/3G/PQR-331
Single V butt
114
Lakshmannan kumar
(FCAW-IS)
weld with û û û NA NA û NA û NA NA û û Accepted
IC.No.0 backing
32568433 (3G)

1. Crack 7. Shrinkage groove


2. Crater crack 8. Excess weld metal (Butt weld)
3. Surface pore 9. Excessive convexity (Fillet weld)
4. Lack of fusion 10. Excess penetration
5. Incomplete root penetration 11. Incomplete filled groove (Butt) / Insufficent throat (Fillet) YES: ü NO: û
6. Under cut 12. Others (Slag,poor restart,stray arc,Spatter)

……………………………………………………… ………………………………………………………………
Examiner or examining body Manufacturer
Name, date and signature Name, date and signature
A-Star Technical Services Pte Ltd Yongnam Engineering & Construction Pte Ltd
FORM No.: ATS/QCP/VT/01 REV.01
A-STAR TESTING & INSPECTION (S) Pte Ltd
No.05 , Soon Lee Street,Pionner Point,#3-36/37, Singapore 627607
Tel: (65)62616162 / 93829286 / fax: (65)62616163
Email: admin@astartesting.com.sg / Website: www.astartesting.com.sg

VISUAL EXAMINATION REPORT Page: 1 of 1


###
Report No : : ATI-YNEC-PQR-VI-019 Client : Yongam Engineering & Construction Pte Ltd
Date of test : : 01.04.19 Test conducted by: A-Star Technical Service (s) Pte Ltd
Acceptance Standard : : BS EN ISO 15614-1 Description : Welding procedure qualification test plate

Ground As Welded Material


Plate Pipe
Visual Weld EN 10025-4 S460M
NA Yes Length 350 mm Dia. : NA
Thk 25 mm Thk : NA Heat Treatment NA

Type Of Equipment Used During Test . (Tick box)

Ruler ü Welding gauge ü Magnifying Glass û Others û

Welding Types of imperfection


PQR no: / Welder Identification Type of Joint Result Remarks
Process
1 2 3 4 5 6 7 8 9 10 11 12
FI/S460/SV-B/002/2G/PQR-332
Single V butt
114
Lakshmannan kumar
(FCAW-IS)
weld with û û û NA NA û NA û NA NA û û Accepted
IC.No.0 32568433 backing
(2G)

1. Crack 7. Shrinkage groove


2. Crater crack 8. Excess weld metal (Butt weld)
3. Surface pore 9. Excessive convexity (Fillet weld)
4. Lack of fusion 10. Excess penetration
5. Incomplete root penetration 11. Incomplete filled groove (Butt) / Insufficent throat (Fillet) YES: ü NO: û
6. Under cut 12. Others (Slag,poor restart,stray arc,Spatter)

……………………………………………………… ………………………………………………………………
Examiner or examining body Manufacturer
Name, date and signature Name, date and signature
A-Star Technical Services Pte Ltd Yongnam Engineering & Construction Pte Ltd
FORM No.: ATS/QCP/VT/01 REV.01
A-STAR TESTING & INSPECTION (S) Pte Ltd
No.05 , Soon Lee Street,Pionner Point,#3-36/37, Singapore 627607
Tel: (65)62616162 / 93829286 / fax: (65)62616163
Email: admin@astartesting.com.sg / Website: www.astartesting.com.sg

VISUAL EXAMINATION REPORT Page: 1 of 1


###
Report No : : ATI-YNEC-PQR-VI-021 Client : Yongam Engineering & Construction Pte Ltd
Date of test : : 01.04.19 Test conducted by: A-Star Technical Service (s) Pte Ltd
Acceptance Standard : : BS EN ISO 15614-1 Description : Welding procedure qualification test plate

Ground As Welded Material


Plate Pipe
Visual Weld EN 10025-4 S460M
NA Yes Length 350 mm Dia. : NA
Thk 25 mm Thk : NA Heat Treatment NA

Type Of Equipment Used During Test . (Tick box)

Ruler ü Welding gauge ü Magnifying Glass û Others û

Welding Types of imperfection


PQR no: / Welder Identification Type of Joint Result Remarks
Process
1 2 3 4 5 6 7 8 9 10 11 12
FI/S460/SV-B/002/3G/PQR-333
Single V butt
114
Shohel
(FCAW-IS)
weld with û û û NA NA û NA û NA NA û û Accepted
IC.No.0 6223671- backing
(3G)

1. Crack 7. Shrinkage groove


2. Crater crack 8. Excess weld metal (Butt weld)
3. Surface pore 9. Excessive convexity (Fillet weld)
4. Lack of fusion 10. Excess penetration
5. Incomplete root penetration 11. Incomplete filled groove (Butt) / Insufficent throat (Fillet) YES: ü NO: û
6. Under cut 12. Others (Slag,poor restart,stray arc,Spatter)

……………………………………………………… ………………………………………………………………
Examiner or examining body Manufacturer
Name, date and signature Name, date and signature
A-Star Technical Services Pte Ltd Yongnam Engineering & Construction Pte Ltd
FORM No.: ATS/QCP/VT/01 REV.01

You might also like