Index: Plug-In Plug-In Plug-In Plug-In Plug-In General Technical Data
Index: Plug-In Plug-In Plug-In Plug-In Plug-In General Technical Data
Index: Plug-In Plug-In Plug-In Plug-In Plug-In General Technical Data
DK Plug-In
S
GB
Plug-In
Plug-In
Date: 01 MAR 19 P
D Plug-In
F Plug-In Index
3x1 M Up to 630 A
3x1.5 M Up to 630 A
3x2 M Up to 630 A
3x3 M Up to 630 A
DFF
DDF
M
3M or 3
2M
The essential differences between MD and Plug-in in the DDF configuration are that Plug-in does not have the option of an isolated
position. Besides, pilot current plugs cannot be integrated at the rear edge of the drawer as in MD.
Drawer sections (type DFF) can be 2M or 3M wide. Drawer sections (type DDF) can be 3M wide.
The conductors from plug to short-circuit protection must be placed according to IEC/EN 61439.
Cable ways can be placed to the left or to the right of the drawer sections depending on the outgoing cables.
Left side is merely an advantage by drawer type DFF.
For 1.5M high drawers pi2d3x15s (DFF) or 4384-0315 (DDF) should be applied, as they make it possible to place the inlet plug in upper
or lower position.
Placement of drawers in top and bottom module (is only posible with drawer type DFF):
Accessibility:
Unless otherwise agreed between the ASSEMBLY manufacturer and the user, operating devices and terminals for cables shall be located
at a height between 0.2 and 2.0 / 2.2 meters above the base of the ASSEMBLY.
For further information, see IEC/EN 61439-1,8.5.5.
2M support holder, end Horizontal covering Covering plate, complete Busbar covering S2000
pit2s
2M pi2sa2s
pi2va2 pit3s
3M pi2sa3s
pi2va3 pit4s
pi2fe2x1s 8M pi2sa8s
9M pi2sa9s
3M support holder, end
Front covering
mdsa1
Shutter, complete
pi2fe3x1s
2M support holder
pi2shs
3P md3bss
4P md4bss
pi2f2x1s
Plug for busbar, top/bottom
pi2f2x2s
pi2f2x3s
pi2f2x4s
3P pi23bss
3M support holder 4P pi24bss
Narrow barrier
pi2f3x1s
pi2f3x2s
pi2f3x3s pi2fl3x1s
pi2f3x4s pi2fl3x15s 4373-0000 4639-0000s
pi23p160s
pi2d2s
pi23p400s
pi2d3s
pi23p630s
pi2d3es
pi2d3x15s Main plug, 4P
Component holder
pi24p160s
pi2ch2s pi24p400s
pi2ch3s pi24p630s
4376-0000
Mounting plate
4384-0301s
4384-0315s
Mounting bracket
pi2m2x15s
pi2m2x2s
pi2m2x3s
0972-0001 pi2m3x15s
pi2m3x1s
Plug covering
pi2m3x2s
pi2m3x3s
3P 3x 3025-0000
4P 4x 3025-0000
160 A
6P 6x 3025-0000 4664-0000s
400 A
8P 8x 3025-0000 630 A 2 x 4664-0000s
4381-0000s
3M support holder
4383-0103s
4383-0203s
4383-0303s
4383-0403s
Side 4649-2100s
Outlet plug in drawer Outlet plug in cable compartment Outlet plug, rear
N
L3
L2
L1
Side
3P 4P 3P - 400A 4382-3400s
160A md3o160s md4o160s 3P - 630A 4382-3630s
400A md3o400s md4o400s 4P - 400A 4382-4400s 3P - 400A 4382-3400s
630A md3o630s md4o630s 4P - 630A 4382-4630s 4P - 400A 4382-4400s
pi2d3s
pi2d2s pi2d3es
4384-0301s and 4384-0315s
Inside drawer: 287 Inside drawer: 479 Inside drawer: 479
Width [mm]
Inside unit: 315 Inside unit: 507 Inside unit: 507
1M 160 160 135 (end)
1.5M 256 256 -
Height [mm]
2M 352 352 -
3M 544 544 -
Inside drawer: 395 Inside drawer: 395 Inside drawer: 395
Depth [mm]
Inside unit: 465 Inside unit: 465 Inside unit: 465
23.436.000 mm3 37.720.800 mm3 31.826.925 mm3
1M
1.430 in3 2.302 in3 1.942 in3
37.497.600 mm3 60.353.280 mm3
1.5M -
2.288 in3 3.683 in3
Volume
51.559.200 mm3 82.985.760 mm3
2M -
3.146 in3 5.064 in3
79.682.400 mm 3
128.250.720 mm 3
3M -
4.863 in3 7.826 in3
The rated current (Inc) and short circuit withstand values (Cut-off and I2t), the values for MD page P1103 can be
Selection of drawer used. Plug-in is equipped with the same plugs, the airflow is the same and the volume is at least the same as for
MD.
pi2ch2s pi2ch3s
Width [mm] 287 479
Height [mm] 135 135
Y
(1M
)
Modules Height of drawer
Y
(1M
)
Y 1.5
(1M 1M M 2M 3M
)
Y Y
(4M (1M
) )
Y
1M 1
(1M
) 2
2M
Y
(1M
1
)
Y
Y (1.5
M)
3M 2
(3M
) 1
Y 4
(1.5
M)
Y 2
(1M 4M
) Y 2 1
(1M
) 1 1
1M
Support holder Support holder
PI2F3x4s PI2F3x2s 2M
1M
Support holder 4M
PI2F3x4s
1M
Support holder
PI2F3x2s 2M
1M
1M
Support holder 1.5M
PI2F3x4s Support holder Support holder
1M PI2F3x3s 3M PI2F3x3s
1.5M
1M
Support holder Support holder Support holder
PI2FE3x1s 1M PI2FE3x1s 1M PI2FE3x1s 1M
Accessibility
Note: 1.5M drawers must be
Unless otherwise agreed between the ASSEMBLY manufacturer and the user, operating devices and fitted on top of each other.
terminals for cables shall be located at a height between 0,2 and 2,0 / 2,2 meters above the base of the
ASSEMBLY. For further information, see IEC/EN 61439-1,8.5.5.