1 Input Data: WWW - Hilti.ch
1 Input Data: WWW - Hilti.ch
1 Input Data: WWW - Hilti.ch
5
Company: Güdel Page: 1
Specifier: gaedim Project: NCC, 6- axis gantry
Address: Fastening Point:
Phone I Fax: | Date: 08.12.2017
E-Mail:
Specifier's comments:
1 Input data
Anchor type and size: HIT-RE 500 V3 + HIT-V(5.8) M30
Effective embedment depth: hef,opti = 147 mm (hef,limit = 330 mm)
Material: 5.8
Approval No.: ETA 16/0143
Issued I Valid: 12.07.2017 | -
Proof: Design method ETAG BOND (EOTA TR 029)
Stand-off installation: eb = 0 mm (no stand-off); t = 40 mm
Baseplate: lx x ly x t = 200 mm x 350 mm x 40 mm; (Recommended plate thickness: not calculated
Profile: Square bar; (L x W x T) = 30 mm x 30 mm x 0 mm
Base material: cracked concrete, C30/37, fc,cube = 37.00 N/mm2; h = 400 mm, Temp. short/long: 40/20 °C
Installation: hammer drilled hole, Installation condition: Dry
Reinforcement: No reinforcement or Reinforcement spacing >= 150 mm (any Ø) or >= 100 mm (Ø <= 10 mm)
no longitudinal edge reinforcement
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.ch Profis Anchor 2.7.5
Company: Güdel Page: 2
Specifier: gaedim Project: NCC, 6- axis gantry
Address: Fastening Point:
Phone I Fax: | Date: 08.12.2017
E-Mail:
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.ch Profis Anchor 2.7.5
Company: Güdel Page: 3
Specifier: gaedim Project: NCC, 6- axis gantry
Address: Fastening Point:
Phone I Fax: | Date: 08.12.2017
E-Mail:
Comments: Tension displacements are valid with half of the required installation torque moment for uncracked concrete! Shear displacements
are valid without friction between the concrete and the baseplate! The gap due to the drilled hole and clearance hole tolerances are not
included in this calculation!
The acceptable anchor displacements depend on the fastened construction and must be defined by the designer!
6 Warnings
• The anchor design methods in PROFIS Anchor require rigid anchor plates per current regulations (ETAG 001/Annex C, EOTA TR029, etc.).
This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the anchor plate is
assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Anchor calculates the minimum
required anchor plate thickness with FEM to limit the stress of the anchor plate based on the assumptions explained above. The proof if the
rigid base plate assumption is valid is not carried out by PROFIS Anchor. Input data and results must be checked for agreement with the
existing conditions and for plausibility!
• Checking the transfer of loads into the base material is required in accordance with EOTA TR 029, Section 7!
• The design is only valid if the clearance hole in the fixture is not larger than the value given in Table 4.1 of EOTA TR029! For larger
diameters of the clearance hole see Chapter 1.1. of EOTA TR029!
• The accessory list in this report is for the information of the user only. In any case, the instructions for use provided with the product have to
be followed to ensure a proper installation.
• Characteristic bond resistances depend on short- and long-term temperatures.
• Please contact Hilti to check feasibility of HIT-V rod supply.
• Edge reinforcement is not required to avoid splitting failure
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.ch Profis Anchor 2.7.5
Company: Güdel Page: 4
Specifier: gaedim Project: NCC, 6- axis gantry
Address: Fastening Point:
Phone I Fax: | Date: 08.12.2017
E-Mail:
7 Installation data
Baseplate, steel: - Anchor type and size: HIT-RE 500 V3 + HIT-V(5.8) M30
Profile: Square bar; 30 x 30 x 0 mm Installation torque: 0.300 kNm
Hole diameter in the fixture: df = 33 mm Hole diameter in the base material: 35 mm
Plate thickness (input): 40 mm Hole depth in the base material: 147 mm
Recommended plate thickness: not calculated Minimum thickness of the base material: 217 mm
Drilling method: Hammer drilled
Cleaning: Compressed air cleaning of the drilled hole according to instructions for use is required
100 100
55
2
175
240
x
175
1
55
100 100
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.ch Profis Anchor 2.7.5
Company: Güdel Page: 5
Specifier: gaedim Project: NCC, 6- axis gantry
Address: Fastening Point:
Phone I Fax: | Date: 08.12.2017
E-Mail:
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan